WorldWideScience

Sample records for rapid liquid-liquid extraction

  1. Liquid-Liquid Extraction Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Jack D. Law; Terry A. Todd

    2008-12-01

    Solvent extraction processing has demonstrated the ability to achieve high decontamination factors for uranium and plutonium while operating at high throughputs. Historical application of solvent extraction contacting equipment implies that for the HA cycle (primary separation of uranium and plutonium from fission products) the equipment of choice is pulse columns. This is likely due to relatively short residence times (as compared to mixer-settlers) and the ability of the columns to tolerate solids in the feed. Savannah River successfully operated the F-Canyon with centrifugal contactors in the HA cycle (which have shorter residence times than columns). All three contactors have been successfully deployed in uranium and plutonium purification cycles. Over the past 20 years, there has been significant development of centrifugal contactor designs and they have become very common for research and development applications. New reprocessing plants are being planned in Russia and China and the United States has done preliminary design studies on future reprocessing plants. The choice of contactors for all of these facilities is yet to be determined.

  2. Chiral separation by enantioselective liquid-liquid extraction

    NARCIS (Netherlands)

    Schuur, B.; Verkuijl, B. J. V.; Minnaard, A. J.; De Vries, J. G.; Heeres, H. J.; Feringa, B. L.

    2011-01-01

    The literature on enantioselective liquid-liquid extraction (ELLE) spans more than half a century of research. Nonetheless, a comprehensive overview has not appeared during the past few decades. Enantioselective liquid-liquid extraction is a technology of interest for a wide range of chemists and

  3. Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography.

    Science.gov (United States)

    Ahmadi-Jouibari, Toraj; Fattahi, Nazir; Shamsipur, Mojtaba

    2014-06-01

    A novel, rapid, simple and sensitive dispersive liquid-liquid microextraction method based on the solidification of floating organic drop (DLLME-SFO) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine amphetamine and methamphetamine in urine samples. The factors affecting the extraction efficiency of DLLME-SFO such as the kind and volume of the extraction and the disperser solvents, effect of concentration of K2CO3 and extraction time were investigated and the optimal extraction conditions were established. Under the optimum conditions (extraction solvent: 30.0μl 1-undecanol; disperser solvent: 300μl acetonitrile; buffer concentration: 2% (w/v) K2CO3 and extraction time: 1min), calibration curves are linear in the range of 10-3000μgl(-1) and limit of detections (LODs) are in the range of 2-8μgl(-1). The relative standard deviations (RSDs) for 100μgl(-1) of amphetamine and methamphetamine in diluted urine are in the range of 6.2-7.8% (n=7). The method was successfully applied for the determination of amphetamine and methamphetamine in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 87.8-113.2%. The obtained results show that DLLME-SFO combined with HPLC-UV is a fast and simple method for the determination of amphetamine and methamphetamine in urine. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Application of an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum.

    Science.gov (United States)

    Chen, Tao; Liu, Yongling; Zou, Denglang; Chen, Chen; You, Jinmao; Zhou, Guoying; Sun, Jing; Li, Yulin

    2014-01-01

    This study presents an efficient strategy based on liquid-liquid extraction, high-speed counter-current chromatography, and preparative HPLC for the rapid enrichment, separation, and purification of four anthraquinones from Rheum tanguticum. A new solvent system composed of petroleum ether/ethyl acetate/water (4:2:1, v/v/v) was developed for the liquid-liquid extraction of the crude extract from R. tanguticum. As a result, emodin, aloe-emodin, physcion, and chrysophanol were greatly enriched in the organic layer. In addition, an efficient method was successfully established to separate and purify the above anthraquinones by high-speed counter-current chromatography and preparative HPLC. This study supplies a new alternative method for the rapid enrichment, separation, and purification of emodin, aloe-emodin, physcione, and chrysophanol. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Rapid determination of lipophilic vitamins in human serum by ultra-high performance liquid chromatography using a fluorinated column and high-throughput miniaturized liquid-liquid extraction.

    Science.gov (United States)

    Cervinkova, Barbora; Krcmova, Lenka Kujovska; Klabackova, Sava; Solichova, Dagmar; Solich, Petr

    2017-09-01

    A high-throughput miniaturized liquid-liquid extraction procedure followed by a simple ultra-high performance liquid chromatography method coupled with fluorescence detection for bioanalytical analysis of all tocopherol isomers and retinol in human serum has been developed and validated. In the extraction procedure, a synthetic internal standard tocol was used, which does not occur in the human body. The separation of structurally related vitamins was achieved using a new generation of pentafluorophenyl propyl core-shell stationary phase with elution using methanol and an aqueous solution of ammonium acetate. The fluorescence of retinol and tocopherol isomers was detected at λex  = 325, 295 nm and λem  = 480, 325 nm, respectively. The rapid baseline separation of all analytes was accomplished within 4.0 min. The sensitivity of method was demonstrated with lower limits of quantification: retinol 0.01 μM, α-tocopherol 0.38 μM, β-tocopherol 0.18 μM, γ-tocopherol 0.14 μM, and δ-tocopherol 0.01 μM. Possible application of this method in clinical practice was confirmed by the analysis of human serum samples from healthy volunteers. Finally, the simultaneous determination of retinol and all tocopherol isomers in human serum can enable the clarification of their role in metabolism and in diseases such as cancer. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Mass transfer. Liquid-liquid extraction with chemical reaction; Transfert de matiere. Extraction liquide-liquide avec reaction chimique

    Energy Technology Data Exchange (ETDEWEB)

    Buch, A.; Rakib, M.; Stambouli, M. [Ecole Centrale de Paris, 75 (France)

    2009-06-15

    The coupling between the mass transfer and the chemical reaction is in the heart of the processes carried out in liquid-liquid extraction called reactive extraction. This coupling is in particular used in industrial applications such as nuclear industry (Purex process..). (O.M.)

  7. Rapid and sensitive analysis of nine fungicide residues in chrysanthemum by matrix extraction-vortex-assisted dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Xue, Jiaying; Chen, Xiaochu; Jiang, Wenqing; Liu, Fengmao; Li, Huichen

    2015-01-15

    A simple sample pretreatment for simultaneous determination of nine fungicides (triadimefon, picoxystrobin, kresoxim-methyl, diniconazole, epoxiconazole, trifloxystrobin, triticonazole, difenoconazole, and azoxystrobin) in chrysanthemum was developed using matrix extraction-vortex-assisted dispersive liquid-liquid microextraction (ME-VADLLME) prior to gas chromatography with electron capture detection. The target fungicides were firstly extracted with acetonitrile and cleaned with the mixture of primary secondary amine and graphite carbon black. The VADLLME procedure was performed by using toluene with lower density than water as the extraction solvent and the acetonitrile extract as the dispersive solvent, respectively. After vortexing and centrifugation, the fine droplet of toluene was collected on the upper of the mixed toluene/acetonitrile/water system using a 0.1-mL pipettor. Under the optimum conditions, the relative recoveries ranged from 73.9 to 95.1% with relative standard deviations of 3.5-9.7% for all of the analytes. The limits of detection were in the range of (0.005-0.05)×10(-3) mg kg(-1). In the proposed method, the ME step provides more effective cleanup for the chrysanthemum matrix, and VADLLME introduces higher sensitivity with the remarkable enrichment factors up to 88-fold compared with the conventional QuEChERS or SPE. The good performance has demonstrated that ME-VADLLME has a strong potential for application in the multi-residue analysis of complex matrices. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Salting-out assisted liquid-liquid extraction for bioanalysis.

    Science.gov (United States)

    Tang, Yong Q; Weng, Naidong

    2013-06-01

    Salting-out assisted liquid-liquid extraction (SALLE) applies the salting-out effect to separate water-miscible organic solvent such as acetonitrile from plasma or other aqueous biofluids, and can extract a wide range of drug and metabolites, including many hydrophilic compounds. In most cases, the separated organic phase can be directly injected for bioanalysis, or with a simple dilution. SALLE provides similar simplicity to protein precipitation, but cleaner extracts due to a true phase separation. SALLE is also faster, more environmentally friendly and more cost-efficient than conventional liquid-liquid extraction and SPE. Through 96-well automation, SALLE can be easily integrated into the overall high-throughput LC-MS/MS bioanalysis strategy to increase productivity. This article provides a critical overview of the literatures on SALLE and perspectives of the future bioanalytical application of this often overlooked extraction technique. Important parameters impacting SALLE-LC-MS/MS assays are also discussed.

  9. Separation of Asphaltenes by Polarity using Liquid-Liquid Extraction

    DEFF Research Database (Denmark)

    Andersen, Simon Ivar

    1997-01-01

    In order to investigate the nature of petroleum asphaltenes in terms of polarity a process was developed using initial liquid-liquid extraction of the oil phase followed by precipitation of the asphaltenes using n-heptane. The liquid-liquid extraction was performed using toluene-methanol mixtures...... with increasing content of toluene. Although large fractions of the crude oil (Alaska ´93) was extracted in the higher polarity solvents (high concentration of methanol), the asphaltene content of the dissolved material was low. As the toluene content increased more asphaltenes were transferred to the solvent...... of the maltene phase also increase while H/C decreases. The content of heteroatoms in the asphaltenes are relatively higher and apparently increase with the polarity of the solvent. It is concluded that these asphaltenes are indeed dominated by high molecular weight substances that cannot be extracted...

  10. Liquid-liquid extraction by reversed micelles in biotechnological processes

    Directory of Open Access Journals (Sweden)

    Kilikian B. V.

    2000-01-01

    Full Text Available In biotechnology there is a need for new purification and concentration processes for biologically active compounds such as proteins, enzymes, nucleic acids, or cells that combine a high selectivity and biocompatibility with an easy scale-up. A liquid-liquid extraction with a reversed micellar phase might serve these purposes owing to its capacity to solubilize specific biomolecules from dilute aqueous solutions such as fermentation and cell culture media. Reversed micelles are aggregates of surfactant molecules containing an inner core of water molecules, dispersed in a continuous organic solvent medium. These reversed micelles are capable of selectively solubilizing polar compounds in an apolar solvent. This review gives an overview of liquid-liquid extraction by reversed micelles for a better understanding of this process.

  11. Mid-infrared and near-infrared spectroscopy for rapid detection of Gardeniae Fructus by a liquid-liquid extraction process.

    Science.gov (United States)

    Tao, Lingyan; Lin, Zhonglin; Chen, Jiashan; Wu, Yongjiang; Liu, Xuesong

    2017-10-25

    Gardeniae Fructus is widely used in the pharmaceutical industry, and many studies have confirmed its medical and economic value. In this study, samples collected from different liquid-liquid extraction batches of Gardeniae Fructus were detected by mid-infrared (MIR) and near-infrared (NIR) spectroscopy. Seven analytes, neochlorogenic acid (5-CQA), cryptochlorogenic acid (4-CQA), chlorogenic acid (3-CQA), geniposidic acid (GEA), deacetyl-asperulosidic acid methyl ester (DAAME), genipin-gentiobioside (GGB), and gardenoside (GA), were chosen as quality property indexes of Gardeniae Fructus. The two kinds of spectra were each used to build models by single partial least squares (PLS). Additionally, both spectral data were combined and modeled by multiblock PLS. For single spectroscopy modeling results, NIR had a better prediction for high-concentration analytes (3-CQA, DAAME, GGB, and GA) whereas MIR performed better for low-concentration analytes (5-CQA, 4-CQA, and GEA). The multiblock methodology was found to be better compared to single spectroscopy models for all seven analytes. Specifically, the coefficients of determination (R2) of the NIR, MIR, and multiblock PLS calibration models of all seven components were higher than 0.95. Relative standard errors of prediction (RSEP) were all less than 7%, except for models of GGB, which were 10.36%, 13.24%, and 8.15% for the NIR-PLS, MIR-PLS, and multiblock models, respectively. These results indicate that MIR and NIR spectrographic techniques could provide a new choice for quality control in industrial production of Gardeniae Fructus. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Liquid-liquid extraction in flow analysis: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Silvestre, Cristina I.C.; Santos, Joao L.M. [REQUIMTE, Servico de Quimica-Fisica, Faculdade de Farmacia, Universidade do Porto, R. Anibal Cunha, 164, 4099-030 Porto (Portugal); Lima, Jose L.F.C., E-mail: limajlfc@ff.up.pt [REQUIMTE, Servico de Quimica-Fisica, Faculdade de Farmacia, Universidade do Porto, R. Anibal Cunha, 164, 4099-030 Porto (Portugal); Zagatto, Elias A.G. [Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, P.O. Box 96, Piracicaba 13400-970 (Brazil)

    2009-10-12

    Liquid-liquid extractions (LLE) are a common sample pre-treatment in many analytical applications. This review aims at providing a critical overview of the distinct automated continuous flow-based approaches that were developed for liquid-liquid extraction with the purpose of pre-concentration and/or separation of multiple analytes, such as ultra-trace metal and metalloid species, phenolic compounds, surfactants, pharmaceuticals, etc., hyphenated with many detection technique such as UV/vis spectrophotometry, atomic spectrometric detection systems and luminescent detectors, including distinct extraction strategies and applications like single and multiple extraction schemes, wetting film extraction, supported liquid membrane extraction, back extraction, closed-loop systems and the utilisation of zone sampling, chromatomembranes and iterative reversal techniques. The analytical performance of the developed flow-based LLE methods and the influence of flow manifold components such as the segmenter, extraction coil and phase separator, is emphasised and object of discussion. An overall presentation of each system components, selectivity, advantages and shortcomings is carried out and exemplified with selected applications.

  13. Liquid-liquid extraction in flow analysis: A critical review.

    Science.gov (United States)

    Silvestre, Cristina I C; Santos, João L M; Lima, José L F C; Zagatto, Elias A G

    2009-10-12

    Liquid-liquid extractions (LLE) are a common sample pre-treatment in many analytical applications. This review aims at providing a critical overview of the distinct automated continuous flow-based approaches that were developed for liquid-liquid extraction with the purpose of pre-concentration and/or separation of multiple analytes, such as ultra-trace metal and metalloid species, phenolic compounds, surfactants, pharmaceuticals, etc., hyphenated with many detection technique such as UV/vis spectrophotometry, atomic spectrometric detection systems and luminescent detectors, including distinct extraction strategies and applications like single and multiple extraction schemes, wetting film extraction, supported liquid membrane extraction, back extraction, closed-loop systems and the utilisation of zone sampling, chromatomembranes and iterative reversal techniques. The analytical performance of the developed flow-based LLE methods and the influence of flow manifold components such as the segmenter, extraction coil and phase separator, is emphasised and object of discussion. An overall presentation of each system components, selectivity, advantages and shortcomings is carried out and exemplified with selected applications.

  14. Hollow fiber-based liquid-liquid-liquid micro-extraction with osmosis: I. Theoretical simulation and verification.

    Science.gov (United States)

    Wu, Qian; Wu, Dapeng; Geng, Xuhui; Shen, Zheng; Guan, Yafeng

    2012-07-27

    Osmosis in hollow fiber-based liquid-liquid-liquid micro-extraction (HF-LLLME) was validated and utilized to improve enrichment factor of extraction in this study. When donor phase (sample solution) with higher ion strength than acceptor phase (extraction phase) was used, osmosis was established from acceptor phase, through organic membrane to donor phase. The mass flux expression of analytes across the organic membrane was established based on the convective-diffusive kinetic model, and the kinetic process for HF-LLLME with osmosis was simulated. Simulation results indicated that osmosis from acceptor phase to donor phase can increase enrichment factor of HF-LLLME, accelerate extraction process, and even result in the distribution ratio of analytes between donor and acceptor phase exceeding their partition coefficient. This phenomenon was verified by the experimental data of extraction with six organic acids and four organic bases as the model analytes. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. [Quality control in liquid-liquid extraction of Reduning injection using near-infrared spectroscopy technology].

    Science.gov (United States)

    Wu, Sha; Liu, Qi-an; Wang, Wei; Su, Guang; Wu, Jian-xiong; Bi, Yu-an; Wang, Zhen-zhong; Xiao, Wei

    2015-02-01

    Quantitative models were established to analyze the content of chlorogenic acid and soluble solid content in the liquid-liquid extraction of Reduning injection by near-infrared (NIR) spectroscopy. Seven batches of extraction solution from the liquid-liquid extraction of Lonicerae Japonicae Flos and Artemisiae Annuae Herba were collected and NIR off-line spectra were acquired. The content of chlorogenic acid and soluble solid content were determined by the reference methods. The partial least square (PLS) and artificial neural networks (ANN) were used to build models to predict the content of chlorogenic acid and soluble solid content in the unknown samples. For PLS models, the R2 of calibration set were 0.9872, 0.9812, RMSEC were 0.1533, 0.7943, the R2 of prediction set were 0.9837, 0.9733, RMSEP were 0.2464, 1.2594, RSEP were 3.25%, 3.31%, for chlorogenic acid and soluble solid content, respectively. For ANN models, the R2 of calibration set were 0.9903, 0.9882, RMSEC were 0.0974, 0.4543, the R2 of prediction set were 0.9868, 0.9699, RMSEP were 0.1920, 0.9427, RSEP were 2.61%, 2.75%, for chlorogenic acid and soluble solid content, respectively. Both the RSEP values of chlorogenic acid and soluble solid content were lower than 6%, which can satisfy the quality control standard in the traditional Chinese medicine production process. The RSEP values of ANN models were lower than PLS models, which indicated the ANN models had better predictive performance for chlorogenic acid and soluble solid content. The established method can rapidly measure the content of chlorogenic acid and soluble solid content. The method is simple, accurate anc reliable, thus can be used for quality control of the liquid-liquid extraction of Reduning injection.

  16. Liquid-Liquid Extraction of Insecticides from Juice: An Analytical Chemistry Laboratory Experiment

    Science.gov (United States)

    Radford, Samantha A.; Hunter, Ronald E., Jr.; Barr, Dana Boyd; Ryan, P. Barry

    2013-01-01

    A laboratory experiment was developed to target analytical chemistry students and to teach them about insecticides in food, sample extraction, and cleanup. Micro concentrations (sub-microgram/mL levels) of 12 insecticides spiked into apple juice samples are extracted using liquid-liquid extraction and cleaned up using either a primary-secondary…

  17. Combination of counter current salting-out homogenous liquid-liquid extraction and dispersive liquid-liquid microextraction as a novel microextraction of drugs in urine samples.

    Science.gov (United States)

    Akramipour, Reza; Fattahi, Nazir; Pirsaheb, Meghdad; Gheini, Simin

    2016-02-15

    The counter current salting-out homogenous liquid-liquid extraction (CCSHLLE) joined with the dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) has been developed as a high preconcentration technique for the determination of different drugs in urine samples. Amphetamines were employed as model compounds to assess the extraction procedure and were determined by high performance liquid chromatography-ultraviolet detection (HPLC-UV). In this method, initially, NaCl as a separation reagent is filled into a small column and a mixture of urine and acetonitrile is passed through the column. By passing the mixture, NaCl is dissolved and the fine droplets of acetonitrile are formed due to salting-out effect. The produced droplets go up through the remained mixture and collect as a separated layer. Then, the collected acetonitrile is removed with a syringe and mixed with 30.0μL 1-undecanol (extraction solvent). In the second step, the 5.00mLK2CO3 solution (2% w/v) is rapidly injected into the above mixture placed in a test tube for further DLLME-SFO. Under the optimum conditions, calibration curves are linear in the range of 1-3000μgL(-1) and limit of detections (LODs) are in the range of 0.5-2μgL(-1). The extraction recoveries and enrichment factors ranged from 78 to 84% and 157 to 168, respectively. Repeatability (intra-day) and reproducibility (inter-day) of method based on seven replicate measurements of 100μgL(-1) of amphetamines were in the range of 3.5-4.5% and 4-5%, respectively. The method was successfully applied for the determination of amphetamines in the actual urine samples. The relative recoveries of urine samples spiked with amphetamine and methamphetamine are 90-108%. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Cation-exchange solid-phase and liquid-liquid extraction for the ...

    African Journals Online (AJOL)

    An existing liquid-liquid extraction (LLE) method was improved in terms of recoveries obtained, by using ethyl acetate as extractant. For pure standards of the khat alkaloids, recoveries ranged from 83 to 97%. Preconcentration, using a Genevac evaporator after the addition of acidified water to the sample, restricted analyte ...

  19. Rapid detection of haloarchaeal carotenoids via liquid-liquid microextraction enabled direct TLC MALDI-MS.

    Science.gov (United States)

    Manikandan, Muthu; Hasan, Nazim; Wu, Hui-Fen

    2013-03-30

    For the first time, we demonstrate the use of TiO2 nanoparticles (NPs) for enhancing the carotenoid production by the extremophilic haloarchea, Haloferax mediterranei. TiO2 NPs at optimal concentration of 375 mg/L results in a 95% increase in the production of carotenoid pigment compared to the control (no TiO2 NPs). The carotenoid pigments extracted from TiO2 NPs treated H. mediterranei cells, were separated using thin layer chromatography (TLC). The separated carotenoid spots were subjected directly for MALDI MS detection. To limit the sample diffusion during matrix addition on TLC plates, a simple bordering mode was exercised. Using this method we were able to detect the pigments successfully using MALDI-MS, directly from TLC plates after separation. In addition, we also applied the Pt NPs capped with ODT via Liquid-liquid microextraction (LLME) for extracting the pigment molecules from the halobacteria in MALDI-MS. These novel NP approaches possess numerous advantages such as; rapidity, ease in synthesis, high sensitivity and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Ternary liquid-liquid equilibria for the phenolic compounds extraction from artificial textile industrial waste

    Science.gov (United States)

    Fardhyanti, Dewi Selvia; Prasetiawan, Haniif; Hermawan, Sari, Lelita Sakina

    2017-03-01

    Liquid waste in textile industry contains large amounts of dyes and chemicals which are capable of harming the environment and human health. It is due to liquid waste characteristics which have high BOD, COD, temperature, dissolved and suspended solid. One of chemical compound which might be harmful for environment when disposed in high concentration is phenol. Currently, Phenol compound in textile industrial waste has reached 10 ppm meanwhile maximum allowable phenol concentration is not more than 0.2 ppm. Otherwise, Phenol also has economic value as feedstock of plastic, pharmaceutical and cosmetic industry. Furthermore, suitable method to separate phenol from waste water is needed. In this research, liquid - liquid extraction method was used with extraction time for 70 minutes. Waste water sample was then separated into two layers which are extract and raffinate. Thereafter, extract and raffinate were then tested by using UV-Vis Spectrophotometer to obtained liquid - liquid equilibrium data. Aim of this research is to study the effect of temperature, stirring speed and type of solvent to obtain distribution coefficient (Kd), phenol yield and correlation of Three-Suffix Margules model for the liquid - liquid extraction data equilibrium. The highest extraction yield at 80.43 % was found by using 70% methanol as solvent at extraction temperature 50 °C with stirring speed 300 rpm, coefficient distribution was found 216.334. From this research it can be concluded that Three-Suffix Margules Model is suitable to predict liquid - liquid equilibrium data for phenol system.

  1. Evaluation of Liquid-Liquid Extraction Process for Separating Acrylic Acid Produced From Renewable Sugars

    Science.gov (United States)

    Alvarez, M. E. T.; Moraes, E. B.; Machado, A. B.; Maciel Filho, R.; Wolf-Maciel, M. R.

    In this article, the separation and the purification of the acrylic acid produced from renewable sugars were studied using the liquid-liquid extraction process. Nonrandom two-liquids and universal quasi-chemical models and the prediction method univeral quasi-chemical functional activity coefficients were used for generating liquid-liquid equilibrium diagrams for systems made up of acrylic acid, water, and solvents (diisopropyl ether, isopropyl acetate, 2-ethyl hexanol, and methyl isobutyl ketone) and the results were compared with available liquid-liquid equilibrium experimental data. Aspen Plus (Aspen Technology, Inc., version 2004.1) software was used for equilibrium and process calculations. High concentration of acrylic acid was obtained in this article using diisopropyl ether as solvent.

  2. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after neu...

  3. Determination of Niacinamide in Lotions and Creams Using Liquid-Liquid Extraction and High-Performance Liquid Chromatography

    Science.gov (United States)

    Usher, Karyn M.; Simmons, Carolyn R.; Keating, Daniel W.; Rossi, Henry F., III

    2015-01-01

    Chemical separations are an important part of an undergraduate chemistry curriculum. Sophomore students often get experience with liquid-liquid extraction in organic chemistry classes, but liquid-liquid extraction is not as often introduced as a quantitative sample preparation method in honors general chemistry or quantitative analysis classes.…

  4. A microfluidic study of liquid-liquid extraction mediated by carbon dioxide.

    Science.gov (United States)

    Lestari, Gabriella; Salari, Alinaghi; Abolhasani, Milad; Kumacheva, Eugenia

    2016-07-05

    Liquid-liquid extraction is an important separation and purification method; however, it faces a challenge in reducing the energy consumption and the environmental impact of solvent (extractant) recovery. The reversible chemical reactions of switchable solvents (nitrogenous bases) with carbon dioxide (CO2) can be implemented in reactive liquid-liquid extraction to significantly reduce the cost and energy requirements of solvent recovery. The development of new effective switchable solvents reacting with CO2 and the optimization of extraction conditions rely on the ability to evaluate and screen the performance of switchable solvents in extraction processes. We report a microfluidic strategy for time- and labour-efficient studies of CO2-mediated solvent extraction. The platform utilizes a liquid segment containing an aqueous extractant droplet and a droplet of a solution of a switchable solvent in a non-polar liquid, with gaseous CO2 supplied to the segment from both sides. Following the reaction of the switchable solvent with CO2, the solvent becomes hydrophilic and transfers from the non-polar solvent to the aqueous droplet. By monitoring the time-dependent variation in droplet volumes, we determined the efficiency and extraction time for the CO2-mediated extraction of different nitrogenous bases in a broad experimental parameter space. The platform enables a significant reduction in the amount of switchable solvents used in these studies, provides accurate temporal characterization of the liquid-liquid extraction process, and offers the capability of high-throughput screening of switchable solvents.

  5. Hybrid Multiphase CFD Solver for Coupled Dispersed/Segregated Flows in Liquid-Liquid Extraction

    Directory of Open Access Journals (Sweden)

    Kent E. Wardle

    2013-01-01

    Full Text Available The flows in stage-wise liquid-liquid extraction devices include both phase segregated and dispersed flow regimes. As a additional layer of complexity, for extraction equipment such as the annular centrifugal contactor, free-surface flows also play a critical role in both the mixing and separation regions of the device and cannot be neglected. Traditionally, computional fluid dynamics (CFD of multiphase systems is regime dependent—different methods are used for segregated and dispersed flows. A hybrid multiphase method based on the combination of an Eulerian multifluid solution framework (per-phase momentum equations and sharp interface capturing using Volume of Fluid (VOF on selected phase pairs has been developed using the open-source CFD toolkit OpenFOAM. Demonstration of the solver capability is presented through various examples relevant to liquid-liquid extraction device flows including three-phase, liquid-liquid-air simulations in which a sharp interface is maintained between each liquid and air, but dispersed phase modeling is used for the liquid-liquid interactions.

  6. Liquid-Liquid Extraction in Systems Containing Butanol and Ionic Liquids – A Review

    Directory of Open Access Journals (Sweden)

    Kubiczek Artur

    2017-03-01

    Full Text Available Room-temperature ionic liquids (RTILs are a moderately new class of liquid substances that are characterized by a great variety of possible anion-cation combinations giving each of them different properties. For this reason, they have been termed as designer solvents and, as such, they are particularly promising for liquid-liquid extraction, which has been quite intensely studied over the last decade. This paper concentrates on the recent liquid-liquid extraction studies involving ionic liquids, yet focusing strictly on the separation of n-butanol from model aqueous solutions. Such research is undertaken mainly with the intention of facilitating biological butanol production, which is usually carried out through the ABE fermentation process. So far, various sorts of RTILs have been tested for this purpose while mostly ternary liquid-liquid systems have been investigated. The industrial design of liquid-liquid extraction requires prior knowledge of the state of thermodynamic equilibrium and its relation to the process parameters. Such knowledge can be obtained by performing a series of extraction experiments and employing a certain mathematical model to approximate the equilibrium. There are at least a few models available but this paper concentrates primarily on the NRTL equation, which has proven to be one of the most accurate tools for correlating experimental equilibrium data. Thus, all the presented studies have been selected based on the accepted modeling method. The reader is also shown how the NRTL equation can be used to model liquid-liquid systems containing more than three components as it has been the authors’ recent area of expertise.

  7. Enhanced flavour extraction in continuous liquid-liquid extractors

    CSIR Research Space (South Africa)

    Apps

    2005-08-12

    Full Text Available stream_source_info apps_2005.pdf.txt stream_content_type text/plain stream_size 10017 Content-Encoding ISO-8859-1 stream_name apps_2005.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Journal of Chromatography A...: +27 12 841 3594. E-mail address: papps@csir.co.za (P. Apps). extraction yields sufficient concentrated extract for repeated analyses under different conditions, as required for exam- ple by aroma dilution analysis [11,12]. CLLE is especially valuable...

  8. Accelerated solvent extraction combined with dispersive liquid-liquid microextraction before gas chromatography with mass spectrometry for the sensitive determination of phenols in soil samples.

    Science.gov (United States)

    Xing, Han-Zhu; Wang, Xia; Chen, Xiang-Feng; Wang, Ming-Lin; Zhao, Ru-Song

    2015-05-01

    A method combining accelerated solvent extraction with dispersive liquid-liquid microextraction was developed for the first time as a sample pretreatment for the rapid analysis of phenols (including phenol, m-cresol, 2,4-dichlorophenol, and 2,4,6-trichlorophenol) in soil samples. In the accelerated solvent extraction procedure, water was used as an extraction solvent, and phenols were extracted from soil samples into water. The dispersive liquid-liquid microextraction technique was then performed on the obtained aqueous solution. Important accelerated solvent extraction and dispersive liquid-liquid microextraction parameters were investigated and optimized. Under optimized conditions, the new method provided wide linearity (6.1-3080 ng/g), low limits of detection (0.06-1.83 ng/g), and excellent reproducibility (solvent extraction with dispersive liquid-liquid microextraction as a sample pretreatment procedure coupled with gas chromatography and mass spectrometry is an excellent method for the rapid analysis of trace levels of phenols in environmental soil samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Removal of nitrogen compounds from Brazilian petroleum samples by oxidation followed by liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Conceicao, L.; Pergher, S.B.C. [Universidade Regional Integrada do Alto Uruguai e das Misses (URI), Erechim, RS (Brazil). Dept. de Quimica], E-mail: pergher@uricer.edu.br; Oliveira, J.V. [Universidade Regional Integrada do Alto Uruguai e das Misses (URI), Erechim, RS (Brazil). Dept. de Engenharia dos Alimentos; Souza, W.F. [Petroleo Brasileiro S.A. (CENPES/PETROBRAS), Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2009-10-15

    This work reports liquid-liquid extraction of nitrogen compounds from oxidized and non-oxidized Brazilian petroleum samples. The experiments were accomplished in a laboratory-scale liquid-liquid apparatus in the temperature range of 303 K-323 K, using methanol, n-methyl-2-pyrrolidone (NMP) and N,Ndimethylformamide (DMF), and their mixtures as extraction solvents, employing solvent to sample volume ratios of 1:2, 1:1 and 2:1, exploring up to three separation stages. Results show that an increase in temperature, solvent to oil ratio, and number of equilibrium stages greatly improves the nitrogen removal from the oxidized sample (from 2600 to 200 ppm). The employed oxidation scheme is thus demonstrated to be an essential and efficient step of sample preparation for the selective liquid-liquid removal of nitrogen compounds. It is shown that the use of mixtures of DMF and NMP as well their use as co-solvents with methanol did not prove to be useful for selective nitrogen extraction since great oil losses were observed in the final process. (author)

  10. Development of a new sample preparation method based on liquid-liquid-liquid extraction combined with dispersive liquid-liquid microextraction and its application on unfiltered samples containing high content of solids.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Abbaspour, Maryam

    2017-11-01

    A new sample preparation method based on liquid-liquid-liquid extraction combined with dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection has been reported for the extraction/preconcentration and determination of trace levels of twelve pesticide residues from different samples with high content of solids without filtration. This method consists of a three-phase system including an aqueous phase (sample solution), acetonitrile, and hexane. The extraction mechanism is based on different affinities of the substances from the sample matrices towards each of the involved phase, which provides a high selectivity to the process. In other words, interfering hydrophobic compounds are transferred into hexane and will not be present in the final extract. Furthermore, ionic and polar compounds are retained in the aqueous phase. Therefore, only semi-polar compounds such as the studied pesticides are extracted into acetonitrile. In this method, a homogeneous solution of the aqueous phase and acetonitrile (a water-soluble extraction solvent) forms two clearly separated phases in the presence of sodium sulfate (as a phase separation agent) and simultaneously the analytes are extracted into the fine droplets of the acetonitrile collected on the surface of the aqueous phase. To achieve high enrichment factors, the acetonitrile phase is mixed with 1,2-dibromoethane (as a preconcentration solvent) at µL-level to perform the following dispersive liquid-liquid microextraction procedure. Several parameters that can affect extraction efficiency including kind and volume of extraction solvent, type and concentration of phase separation agent, hexane volume, kind of preconcentration solvent, and ionic strength were studied and optimized. Under the optimal conditions, extraction recoveries were obtained in the range of 53-93% and the calibration curves were linear in wide ranges with correlation coefficients ≥ 0.9983. Intra- (n = 6) and

  11. Separation of Molybdenum, Vanadium and Nickel by Liquid-Liquid Extraction

    OpenAIRE

    COŞAR, T.

    2014-01-01

    Elements in the ash of asphaltites that is used in thermal central for power generation units are Mo, V, U, Ti and Ni. The main goal of this study was to separate molybdenum, vanadium and nickel from the aqueous solution. The quantities of the above elements in solution were in the range of 50-80 ppm. The separate these elements from solution, the liquid-liquid extraction method was applied to samples. Alamine 336 was used as extractant. During the reduction-oxidation processes, single and mu...

  12. Rapid analysis of aflatoxins B1, B2, and ochratoxin A in rice samples using dispersive liquid-liquid microextraction combined with HPLC.

    Science.gov (United States)

    Lai, Xian-Wen; Sun, Dai-Li; Ruan, Chun-Qiang; Zhang, He; Liu, Cheng-Lan

    2014-01-01

    A novel, simple, and rapid method is presented for the analysis of aflatoxin B1, aflatoxin B2, and ochratoxin A in rice samples by dispersive liquid-liquid microextraction combined with LC and fluorescence detection. After extraction of the rice samples with a mixture of acetonitrile/water/acetic acid, mycotoxins were rapidly partitioned into a small volume of organic solvent (chloroform) by dispersive liquid-liquid microextraction. The three mycotoxins were simultaneously determined by LC with fluorescence detection after precolumn derivatization for aflatoxin B1 and B2. Parameters affecting both extraction and dispersive liquid-liquid microextraction procedures, including the extraction solvent, the type and volume of extractant, the volume of dispersive solvent, the addition of salt, the pH and the extraction time, were optimized. The optimized protocol provided an enrichment factor of approximately 1.25 and with detection of limits (0.06-0.5 μg/kg) below the maximum levels imposed by current regulations for aflatoxins and ochratoxin A. The mean recovery of three mycotoxins ranged from 82.9-112%, with a RSD less than 7.9% in all cases. The method was successfully applied to measure mycotoxins in commercial rice samples collected from local supermarkets in China. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Optimizing performance of liquid-liquid extraction in stratified flow in micro-channels

    Science.gov (United States)

    Malengier, B.; Pushpavanam, S.; D'haeyer, S.

    2011-11-01

    Several applications such as liquid-liquid extraction in micro-fluidic devices are concerned with the flow of two immiscible liquid phases. Two characteristic flow regimes are observed in these systems: the stratified flow and the slug flow. In this work, two phase (liquid-liquid) stratified flows in a rectangular geometry are first analyzed. The influence of physical properties, in particular the viscosity of the two liquids, on the velocity profiles is determined analytically. The flow profiles are classified in the parameter space of physical properties (viscosity ratio) and operating conditions (flow-rate ratio). Viscosity affects the shapes of the velocity profile and the dispersion of a solute in each phase. The question addressed is: can the viscosity of a fluid be exploited to improve extraction efficiency? This would then give us an extra degree of freedom to control and improve extraction efficiency when there can be more than one possible candidate for extractant. The mass transfer behavior in the liquid-liquid system is numerically simulated using both a finite-difference and a finite-volume method. This helps understanding of the role of various operating conditions as pressure drop, flow rate, etc on the behavior of the system. Our analysis can be used to establish guidelines for carrying out experiments. It is found that the effect of the difference in the shape of the flow profiles on mass transfer is not very significant for some modes of operation. The predictions of our model are compared with experimental results from the literature.

  14. Salting-out assisted liquid-liquid extraction coupled to dispersive liquid-liquid microextraction for the determination of chlorophenols in wine by high-performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Hu, Shibin; Liu, Shuhui

    2014-12-01

    A novel procedure of sample preparation combined with high-performance liquid chromatography with diode array detection is introduced for the analysis of highly chlorinated phenols (trichlorophenols, tetrachlorophenols, and pentachlorophenol) in wine. The main features of the proposed method are (i) low-toxicity diethyl carbonate as extraction solvent to selectively extract the analytes without matrix effect, (ii) the combination of salting-out assisted liquid-liquid extraction and dispersive liquid-liquid microextraction to achieve an enrichment factor of 334-361, and (iii) the extract is analyzed by high-performance liquid chromatography to avoid derivatization. Under the optimum conditions, correlation coefficients (r) were >0.997 for calibration curves in the range 1-80 ng/mL, detection limits and quantification limits ranged from 0.19 to 0.67 and 0.63 to 2.23 ng/mL, respectively, and relative standard deviation was <8%. The method was applied for the determination of chlorophenols in real wines, with recovery rates in the range 82-104%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Uranium monitoring tool for rapid analysis of environmental samples based on automated liquid-liquid microextraction.

    Science.gov (United States)

    Rodríguez, Rogelio; Avivar, Jessica; Ferrer, Laura; Leal, Luz O; Cerdà, Víctor

    2015-03-01

    A fully automated in-syringe (IS) magnetic stirring assisted (MSA) liquid-liquid microextraction (LLME) method for uranium(VI) determination was developed, exploiting a long path-length liquid waveguide capillary cell (LWCC) with spectrophotometric detection. On-line extraction of uranium was performed within a glass syringe containing a magnetic stirrer for homogenization of the sample and the successive reagents: cyanex-272 in dodecane as extractant, EDTA as interference eliminator, hydrochloric acid to make the back-extraction of U(VI) and arsenazo-III as chromogenic reagent to accomplish the spectrophotometric detection at 655 nm. Magnetic stirring assistance was performed by a specially designed driving device placed around the syringe body creating a rotating magnetic field in the syringe, and forcing the rotation of the stirring bar located inside the syringe. The detection limit (LOD) of the developed method is 3.2 µg L(-1). Its good interday precision (Relative Standard Deviation, RSD 3.3%), and its high extraction frequency (up to 6 h(-1)) makes of this method an inexpensive and fast screening tool for monitoring uranium(VI) in environmental samples. It was successfully applied to different environmental matrices: channel sediment certified reference material (BCR-320R), soil and phosphogypsum reference materials, and natural water samples, with recoveries close to 100%. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Compensating effect of ultrasonic waves on retarding action of nanoparticles in drops liquid-liquid extraction.

    Science.gov (United States)

    Saien, Javad; Daneshamoz, Sana

    2018-03-01

    The influence of ultrasonic waves on liquid-liquid extraction of circulating drops and in the presence of magnetite nanoparticles was investigated. Experiments were conducted in a column equipped with an ultrasound transducer. The frequency and intensity of received waves, measured by the hydrophone standard method, were 35.40 kHz and 0.37 mW/cm 2 , respectively. The recommended chemical system of cumene-isobutyric acid-water was used in which mass transfer resistance lies in the aqueous phase. Nanoparticles, within concentration range of (0.0003-0.0030) wt%, were added to the aqueous continuous phase. The presence of nanoparticles and ultrasonic waves provided no sensible change in drop size (within 2.49-4.17 mm) and measured terminal velocities were close to Grace model. However, presence of nanoparticles, caused mass transfer to decrease. This undesired effect was significantly diminished by using ultrasonic waves so that mass transfer coefficient increased from (73.0-178.2) to (130.2-240.2) µm/s, providing a 55.6% average enhancement. It is presumably due to disturbing the accumulated nanoparticles around the drops. The current innovative study highlights the fact that using ultrasonic waves is an interesting way to improve liquid-liquid extraction in the presence and absence of nanoparticles. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Ultrapreconcentration and determination of organophosphorus pesticides in water by solid-phase extraction combined with dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Chen, Junhua; Zhou, Guangming; Deng, Yongli; Cheng, Hongmei; Shen, Jie; Gao, Yi; Peng, Guilong

    2016-01-01

    Solid-phase extraction coupled with dispersive liquid-liquid microextraction was developed as an ultra-preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion-methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid-phase extraction coupled with dispersive liquid-liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid-phase extraction coupled with dispersive liquid-liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9-6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Rapid screening of oxytetracycline residue in catfish muscle by dispersive liquid-liquid microextraction and europium-sensitized luminescence

    Science.gov (United States)

    Oxytetracycline (OTC) residue in catfish muscle was screened by dispersive liquid-liquid microextraction (DLLME) and europium-sensitized luminescence (ESL). After extraction in EDTA, HCl, and acetonitrile, cleanup was carried out by DLLME, and ESL was measured at microgram = 385 nm and wavelength = ...

  19. Hollow fiber-based liquid-liquid-liquid micro-extraction with osmosis: II. Application to quantification of endogenous gibberellins in rice plant.

    Science.gov (United States)

    Wu, Qian; Wu, Dapeng; Duan, Chunfeng; Shen, Zheng; Guan, Yafeng

    2012-11-23

    The phenomenon and benefits of osmosis in hollow fiber-based liquid-liquid-liquid micro-extraction (HF-LLLME) were theoretically discussed in part I of this study. In this work, HF-LLLME with osmosis was coupled with high performance liquid chromatography-triple quadrupole mass spectrometry (HPLC-triple quadrupole MS/MS) to analyze eight gibberellins (gibberellin A(1), gibberellin A(3), gibberellin A(4), gibberellin A(7), gibberellin A(8), gibberellin A(9), gibberellin A(19) and gibberellin A(20)) in rice plant samples. According to the theory of HF-LLLME with osmosis, single factor experiments, orthogonal design experiments and mass transfer simulation of extraction process were carried out to select the optimal conditions. Cyclohexanol - n-octanol (1:3, v/v) was selected as organic membrane. Donor phase of 12 mL was adjusted to pH 2 and 20% NaCl (w/v) was added. Acceptor phase with an initial volume of 20 μL was the solution of 0.12 mol L(-1) Na(2)CO(3)-NaHCO(3) buffer (pH 9). Temperature was chosen to be 30 °C and extraction time was selected to be 90 min. Under optimized conditions, this method provided good linearity (r, 0.99552-0.99991) and low limits of detection (0.0016-0.061 ng mL(-1)). Finally, this method was applied to the analysis of endogenous gibberellins from plant extract which was obtained with traditional solvent extraction of rice plant tissues, and the relative recoveries were from 62% to 166%. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. The Liquid-Liquid Extraction of Toxic Metals (Cd, Hg and Pb by Calixarenes

    Directory of Open Access Journals (Sweden)

    D. Max Roundhill

    2009-12-01

    Full Text Available Toxic metals (Cd, Hg and Pb are mostly present in the environment due to natural phenomenon and human activities as well. Exposure of these non-essential elements in the environment causes severe effects. They are known to cause problems in humans as well as in aquatic life. In this work, we demonstrate various studies regarding liquid-liquid extraction of selected ions with different functionalized calixarenes. This review article briefly discusses several molecular designs of calixarenes for divalent ion (Cd2+, Hg2+ and Pb2+ recognition; as well as the relationship between structure and selectivity of the macrocycles is elaborated. The article does not, however, attempt to cover all of the different approaches to these toxic metal ions extraction.

  1. Advancing liquid/liquid extraction through a novel microfluidic device: Theory, instrumentation and applications in gas chromatography

    NARCIS (Netherlands)

    Peroni, D.; van Egmond, W.; Kok, W.T.; Janssen, J.G.M.

    2012-01-01

    A new chip-based liquid-liquid extraction technique for sample preparation of aqueous samples for GC was developed. Extraction is performed in a segmented flow system with additional mixing provided by an etched channel structure. The dimensions of the device are optimized to allow benefiting of the

  2. Continuous chiral separation of amino acid derivatives by enantioselective liquid-liquid extraction in centrifugal contactor separators

    NARCIS (Netherlands)

    Schuur, Boelo; Floure, Joelle; Hallett, Andrew J.; Winkelman, Jozef G.M.; Vries, Johannes G. de; Heeres, Hero J.

    2008-01-01

    The continuous enantioselective liquid-liquid extraction of aqueous 3,5-dinitrobenzoyl-D,L-leucine (DNB-d,l-leu) by a cinchona alkaloid extractant (CA) in 1,2-dichloroethane using a centrifugal contact separator (CCS) was studied at 294 K. Typical concentrations were in the order of 1 mM for both

  3. Determination of diflubenzuron and chlorbenzuron in fruits by combining acetonitrile-based extraction with dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Ruan, Chunqiang; Zhao, Xiang; Liu, Chenglan

    2015-09-01

    In this study, a simple and low-organic-solvent-consuming method combining an acetonitrile-partitioning extraction procedure followed by "quick, easy, cheap, effective, rugged and safe" cleanup with ionic-liquid-based dispersive liquid-liquid microextraction and high-performance liquid chromatography with diode array detection was developed for the determination of diflubenzuron and chlorbenzuron in grapes and pears. Ionic-liquid-based dispersive liquid-liquid microextraction was performed using the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate as the extractive solvent and acetonitrile extract as the dispersive solvent. The main factors influencing the efficiency of the dispersive liquid-liquid microextraction were evaluated, including the extractive solvent type and volume and the dispersive solvent volume. The validation parameters indicated the suitability of the method for routine analyses of benzoylurea insecticides in a large number of samples. The relative recoveries at three spiked levels ranged between 98.6 and 109.3% with relative standard deviations of less than 5.2%. The limit of detection was 0.005 mg/kg for the two insecticides. The proposed method was successfully used for the rapid determination of diflubenzuron and chlorbenzuron residues in real fruit samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Dispersive liquid-liquid microextraction coupled with magnetic nanoparticles for extraction of zearalenone in wheat samples

    Directory of Open Access Journals (Sweden)

    Mitra Amoli-Diva

    2017-01-01

    Full Text Available A new, sensitive and fast dispersive liquid-liquid microextraction (DLLME coupled with micro-solid phase extraction (μ-SPE was developed for determination of zearalenone (ZEN in wheat samples. The DLLME was performed using acetonitrile/water (80:20 v/v as the disperser solvent and 1-octanol as the extracting solvent.  The acetonitrile/water (80:20 v/v solvent was also used to extract ZEN from solid wheat matrix, and was directly applied as the disperser solvent for DLLME process. Additionally, hydrophobic oleic-acid-modified magnetic nanoparticles were used in μ-SPE approach to retrieve the analyte from the DLLME step. So, the method uses high surface area and strong magnetism properties of these nanoparticles to avoid time-consuming column-passing processes in traditional SPE. Main parameters affecting the extraction efficiency and signal enhancement were investigated and optimized. Under the optimum conditions, the calibration curve showed a good linearity in the range of 0.1-500 μg kg−1 (R2=0.9996 with low detection limit of 83 ng g−1. The intra-day and inter-day precisions (as RSD % in the range of 2.6-4.3 % and high recoveries ranging from 91.6 to 99.1 % were obtained. The pre-concentration factor was 3. The method is simple, inexpensive, accurate and remarkably free from interference effects.

  5. Homogeneous liquid-liquid extraction method for the selective separation and preconcentration of ultra trace molybdenum.

    Science.gov (United States)

    Ghiasvand, A R; Shadabi, S; Mohagheghzadeh, E; Hashemi, P

    2005-05-15

    A new simple and efficient homogeneous liquid-liquid extraction method for the selective separation and preconcentration of molybdenyl ions was developed. alpha-Benzoin oxime (ABO) was investigated as a complexing ligand, and perfluorooctanoate ion (PFOA(-)) was applied as a phase-separator agent under strongly acidic conditions. Under the optimal conditions ([ABO]=2.1x10(-3)M, [PFOA(-)]=1.8x10(-2)M, [HNO(3)]=1.7M, [acetone]=11.8% (v/v)), 10mug of molybdenum in 5ml aqueous phase could be extracted quantitatively into 40mul of the sedimented phase. The maximum concentration factor was 125-fold. Thiocyanate was applied as a chromogenic reagent for the direct spectrophotometric determination of molybdenum in the sedimented phase. The reproducibility of the proposed method is at the most 2.4%. The influence of the type and concentration of acid solution, the concentration of ABO, the type and volume of the water-miscible organic solvent, the concentration of PFOA(-), and the effect of different diverse ions on the extraction and determination of molybdenum(VI) were investigated. The proposed method was applied to the extraction and determination of molybdenum(VI) in natural water, Spinach, and Lucerne samples. A satisfactory agreement exists between the results obtained by the proposed method and those reported by GF-AAS.

  6. Scalable enantioseparation of amino acid derivatives using continuous liquid-liquid extraction in a cascade of centrifugal contactor separators

    NARCIS (Netherlands)

    Schuur, Boelo; Hallett, Andrew J.; Winkelman, Jozef G.M.; Vries, Johannes G. de; Heeres, Hero J.

    2009-01-01

    Using a cascade of six centrifugal contactor separators in a countercurrent liquid-liquid extraction mode allowed the separation of one of the enantiomers of 3,5-dinitrobenzoyl-leucine in 55% yield and 98% ee using a catalytic amount of a chiral host compound based on a cinchona alkaloid, This

  7. The continuous-flow synthesis of carbazate hydrazones using a simplified computer-vision controlled liquid-liquid extraction system

    OpenAIRE

    O'Brien, M.; Cooper, D.; Mhembere, P

    2016-01-01

    A computer-vision controlled liquid-liquid extraction system was used in the continuous-flow synthesis of a series of carbazate hydrazones. The system uses open-source software components (Python, OpenCV) and is simpler and potentially more economical, in terms of hardware, than one we have described previously.

  8. Structure of a liquid/liquid interface during solvent extraction combining X-ray and neutron reflectivity measurements.

    Science.gov (United States)

    Scoppola, E; Watkins, E; Li Destri, G; Porcar, L; Campbell, R A; Konovalov, O; Fragneto, G; Diat, O

    2015-06-21

    We have resolved the molecular structure of a bulk oil/water interface that contains amphiphilic ligand molecules using a combination of X-ray and neutron reflectivity measurements for the first time. This new capability can greatly impact future work in the field of ion separation by phase transfer, i.e. liquid/liquid extraction.

  9. CONTRIBUTION TO THE DEVELOPMENT OF A SIMULATION SOFTWARE PERFORMANCE AND SHARING RATIO IN LIQUID-LIQUID EXTRACTION

    Directory of Open Access Journals (Sweden)

    A. Hadj Seyd

    2015-07-01

    Full Text Available The present work is to develop software to predict the value yield and the distribution coefficient in the process of liquid-liquid extraction of components of a mixture, from mathematical models expressing these entities, based on equations equilibrium between liquid-liquid phases, and predict the conditions under which the extraction operation is favorable, unfavorable or impossible to realize, by studying the variation of the entities cited, based on the parameters influencing the extraction, which are: initial concentrations, rate of solvent and pH, in the case of a simple extraction (extraction of neutral products or when it is reactive (extraction of complex acids or bases for one or more components.The programming language used is "Delphi" which is a very powerful oriented object programming under Windows.

  10. Liquid-Liquid Extraction of Transition Metal Cations by Glyoximes and Their Macrocyclic Glyoxime Ether Derivatives

    Directory of Open Access Journals (Sweden)

    Nazan Karapinar

    2013-01-01

    Full Text Available Liquid-liquid extraction of various alkalis (Li+, Na+, K+, and Cs+, transition metals (Co2+, Ni2+, Cu2+, Zn2+, Cd2+, and Hg2+, and Pb2+ cations with phenylglyoxime (L1, p-tolylglyoxime (L2, N′-(4′-Benzo[15-crown-5]phenylaminoglyoxime (L3, and N′-(4′-Benzo[15-crown-5]-p-tolylaminoglyoxime (L4 from the aqueous phase into the organic phase was carried out. For comparison, the corresponding two glyoximes and their macrocyclic glyoxime ether derivatives were also examined. Crown ether groups having ligands (L3, L4 carry especially Na+ cation from aqueous phase to organic phase. The extraction equilibrium constants (Kex for complexes of ligands with Cu2+ and Hg2+ metal picrates between dichloromethane and water have been determined at 25°C. The values of the extraction constants (logKex were determined to be 12.27, 13.37, 12.94, and 12.39 for Cu2+ and 10.29, 10.62, 11.53, and 11.97 for Hg2+ with L1–L4, respectively.

  11. Liquid-liquid extraction of uranium(VI) in the system with a membrane contactor.

    Science.gov (United States)

    Biełuszka, Paweł; Zakrzewska, Grażyna; Chajduk, Ewelina; Dudek, Jakub

    Raising role of the nuclear power industry, including governmental plans for the construction of first nuclear power plant in Poland, creates increasing demand for the uranium-based nuclear fuels. The project implemented by Institute of Nuclear Chemistry and Technology concerns the development of effective methods for uranium extraction from low-grade ores and phosphorites for production of yellow cake-U 3 O 8 . The Liqui-Cel ® Extra-Flow 2.5 × 8 Membrane Contactor produced by CELGARD LLC (Charlotte, NC) company is the main component of the installation for liquid-liquid extraction applied for processing of post leaching liquors. In the process of membrane extraction the uranyl ions from aqueous phase are transported through the membrane into organic phase. The flow of two phases in the system was arranged in co-current mode. The very important element of the work was a selection of extracting agents appropriate for the membrane process. After preliminary experiments comprising tests of membrane resistivity and determination of extraction efficiency, di(2-ethylhexyl)phosphoric acid was found to be most favourable. An important aspect of the work was the adjustment of hydrodynamic conditions in the capillary module. To avoid the membrane wettability by organic solvent and mixing two phases equal pressure drops along the membrane module to minimize the transmembrane pressure, were assumed. Determination of pressure drop along the module was conducted using Bernoulli equation. The integrated process of extraction/re-extraction conducted in continuous mode with application of two contactors was designed.

  12. Simplified recovery process of Ralstonia solanacearum-synthesized polyhydroxyalkanoates via chemical extraction complemented by liquid-liquid phase separation

    Directory of Open Access Journals (Sweden)

    Karine L. Macagnan

    Full Text Available Poly (3-hydroxybutyrate (P(3HB is the most studied thermoplastic biopolymer belonging to the polyhydroxyalkanoate (PHA family, the main features of which include rapid biodegradability and biocompatibility. The bioplastic recovery process is an important step during production and can directly influence the characteristics of PHAs. However, more efficient methods for the production of P(3HB are necessary to make it economically viable. The aim of the present study was to improve the standard, chloroform-based, extraction step for the recovery of P(3HB. The polymer was produced using a Ralstonia solanacearum strain. The following parameters were improved in the recovery process: heating time, separation method (filtration or liquid-liquid phase separation, biomass state (fresh or dry cell concentrate and the solvent:biomass ratio. By improving the chemical extraction of P(3HB we recovered 98% of the cumulative polymer and reduced the heating time by 75%. Furthermore, we improved the separation process and developed an extraction solution that was faster and more economical.

  13. Ionic liquid based dispersive liquid-liquid microextraction for the extraction of pesticides from bananas.

    Science.gov (United States)

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Asensio-Ramos, María; Rodríguez-Delgado, Miguel Angel

    2009-10-23

    This paper describes a dispersive liquid-liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled to high-performance liquid chromatography with diode array detection capable of quantifying trace amounts of eight pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox and fenazaquin) in bananas. Fruit samples were first homogenized and extracted (1g) with acetonitrile and after suitable evaporation and reconstitution of the extract in 10 mL of water, a DLLME procedure using 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) as extraction solvent was used. Experimental conditions affecting the DLLME procedure (sample pH, sodium chloride percentage, ionic liquid amount and volume of disperser solvent) were optimized by means of an experimental design. In order to determine the presence of a matrix effect, calibration curves for standards and fortified banana extracts (matrix matched calibration) were studied. Mean recovery values of the extraction of the pesticides from banana samples were in the range of 69-97% (except for thiophanate-methyl and carbofuran, which were 53-63%) with a relative standard deviation lower than 8.7% in all cases. Limits of detection achieved (0.320-4.66 microg/kg) were below the harmonized maximum residue limits established by the European Union (EU). The proposed method, was also applied to the analysis of this group of pesticides in nine banana samples taken from the local markets of the Canary Islands (Spain). To the best of our knowledge, this is the first application of RTILs as extraction solvents for DLLME of pesticides from samples different than water.

  14. SYNTHESE D’EXTRACTANTS ACIDES HEXADECYL- ET DECYLAMINOBIMETHYLENEDIPHOSPHONIQUES APPLICATION A L’EXTRACTION LIQUIDE-LIQUIDE DE Ni (II

    Directory of Open Access Journals (Sweden)

    M.A DIDI

    2007-06-01

    Après purification puis caractérisation des produits, nous avons réalisé divers tests d’extraction liquide - liquide de Ni (II en milieu sulfaté. Le temps d’équilibre déterminé par étude cinétique a été fixé à 40 minutes. Les paramètres changeant tels la température ( T = 20°C, 30°C et 50°C, le rapport du nombre de moles (n extractant / n métal (Q =1 à 6 et le rapport des volumes (Vaq / Vorg= 1, 2, 3 et 4 ont permis de maximiser le rendement d’extraction qui est de 46% avec le HABMP et de 44% pour le DADMP et ceci pour des extractions à un seul plateau.

  15. Pesticide extraction from table grapes and plums using ionic liquid based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Ravelo-Pérez, Lidia M; Hernández-Borges, Javier; Herrera-Herrera, Antonio V; Rodríguez-Delgado, Miguel Angel

    2009-12-01

    Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 microg/kg for plums, representing LODs below the maximum residue limits (MRLs) established by the European Union in these fruits. The potential of the method was demonstrated by analyzing 12 commercial fruit samples (six of each type).

  16. Headspace single drop microextraction versus dispersive liquid-liquid microextraction using magnetic ionic liquid extraction solvents.

    Science.gov (United States)

    An, Jiwoo; Rahn, Kira L; Anderson, Jared L

    2017-05-15

    A headspace single drop microextraction (HS-SDME) method and a dispersive liquid-liquid microextraction (DLLME) method were developed using two tetrachloromanganate ([MnCl42-])-based magnetic ionic liquids (MIL) as extraction solvents for the determination of twelve aromatic compounds, including four polyaromatic hydrocarbons, by reversed phase high-performance liquid chromatography (HPLC). The analytical performance of the developed HS-SDME method was compared to the DLLME approach employing the same MILs. In the HS-SDME approach, the magnetic field generated by the magnet was exploited to suspend the MIL solvent from the tip of a rod magnet. The utilization of MILs in HS-SDME resulted in a highly stable microdroplet under elevated temperatures and long extraction times, overcoming a common challenge encountered in traditional SDME approaches of droplet instability. The low UV absorbance of the [MnCl42-]-based MILs permitted direct analysis of the analyte enriched extraction solvent by HPLC. In HS-SDME, the effects of ionic strength of the sample solution, temperature of the extraction system, extraction time, stir rate, and headspace volume on extraction efficiencies were examined. Coefficients of determination (R2) ranged from 0.994 to 0.999 and limits of detection (LODs) varied from 0.04 to 1.0μgL-1 with relative recoveries from lake water ranging from 70.2% to 109.6%. For the DLLME method, parameters including disperser solvent type and volume, ionic strength of the sample solution, mass of extraction solvent, and extraction time were studied and optimized. Coefficients of determination for the DLLME method varied from 0.997 to 0.999 with LODs ranging from 0.05 to 1.0μgL-1. Relative recoveries from lake water samples ranged from 68.7% to 104.5%. Overall, the DLLME approach permitted faster extraction times and higher enrichment factors for analytes with low vapor pressure whereas the HS-SDME approach exhibited better extraction efficiencies for analytes with

  17. The removal of dinitrochlorobenzene from industrial residuals by liquid-liquid extraction with chemical reaction

    Directory of Open Access Journals (Sweden)

    G. C. M. Ferreira

    2007-09-01

    Full Text Available Nitrochlorobenzenes (NCBs are very important in the chemical industry since they have been used as raw material for the manufacture of crop protection products, as active ingredients in the pharmaceutical industry, as pigments and as antioxidants as well as for other uses. In industrial processes, NCBs are produced by monochlorobenzene (MCB nitration reactions and one of the main residuals formed is dinitrochlorobenzene (DNCB, which is mainly composed of the isomer 2,4DNCB. This subproduct, although of commercial interest when in its pure state, is generally incinerated due to the high costs of recovery treatment and purification. The objective of this study is to present an alternative to the treatment of industrial residuals containing DNCB. The technique consists of converting DNCB into sodium dinitrophenolate, which is very soluble in water and is also easy to reuse. For this purpose, liquid-liquid extraction with chemical reaction (alkaline hydrolysis with a rotating disc contactor (RDC is used. Experimental data on MCB nitration reactions as well as alkaline hydrolysis using a rotating disc contactor are presented.

  18. Determination of the equilibrium constants of organophosphorus liquid-liquid extractants by inductively coupled Plasma-Atomic Emission Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ke-an, L.; Muralidharan, S.; Freiser, H.

    1985-12-01

    The technique of inductively coupled Plasma-Atomic Emission Spectroscopy (ICP) has been used for determining the equilibrium constants of organophosphorus extractants in liquid-liquid extraction systems. The 213.618 nm first order atomic emission line of phosphorus was monitored to determine the equilibrium constants. The relevant equilibrium constants of bis(2,4,4-trimethylpentyl)phosphinic acid, bis(2-ethylhexyl)phosphoric acid, diphenylphosphinic acid, trioctylphosphine oxide and tri-n-butylphosphate have been determined in this manner. It has been demonstrated for the first time that the equilibrium constants for liquid-liquid extractants can be determined in a facile manner using ICP. 14 references, 1 figure, 1 table.

  19. Analysis of aflatoxins in nonalcoholic beer using liquid-liquid extraction and ultraperformance LC-MS/MS.

    Science.gov (United States)

    Khan, Mohammad R; Alothman, Zeid A; Ghfar, Ayman A; Wabaidur, Saikh M

    2013-02-01

    Aflatoxins AFB1, AFB2, AFG1, and AFG2 are toxic secondary metabolites produced by Aspergillus flavus and Aspergillus parasiticus and posses a potential threat to food safety. In the present work, liquid-liquid extraction and ultraperformance LC-MS/MS method has been applied for the determination of four naturally occurring aflatoxins AFB1, AFB2, AFG1, and AFG2 in nonalcoholic beer. Aflatoxins extraction from nonalcoholic beer was carried out using liquid-liquid extraction procedure. The effects of solvent-types were studied to obtain maximum recovery of the target analytes with minimum contamination. Among different solvents, the aflatoxins extraction was best achieved using ethyl acetate. The obtained recoveries were ranged from 85 to 96% with good quality parameters: LOD values between 0.001 and 0.003 ng/mL, linearity of the calibration curve (r(2) > 0.999), and repeatability (run-to-run) and reproducibility (day-to-day) precisions with RSDs lower than 5% (n = 5) achieved at 0.50 ng/mL concentration. The optimized liquid-liquid extraction in combination with ultraperformance LC-MS/MS was applied successfully to the analysis of AFB1, AFB2, AFG1, and AFG2 aflatoxins in 11 nonalcoholic beers and were detected up to 15.31 ng/L in some of the samples. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A novel liquid/liquid extraction process composed of surfactant and acetonitrile for purification of polygalacturonase enzyme from Durio zibethinus.

    Science.gov (United States)

    Amid, Mehrnoush; Manap, Yazid; Azmira, Farhana; Hussin, Muhaini; Sarker, Zaidul Islam

    2015-07-01

    Polygalacturonase is one of the important enzymes used in various industries such as food, detergent, pharmaceutical, textile, pulp and paper. A novel liquid/liquid extraction process composed of surfactant and acetonitrile was employed for the first time to purify polygalacturonase from Durio zibethinus. The influences of different parameters such as type and concentration of surfactants, concentrations of acetonitrile and composition of surfactant/acetonitrile on partitioning behavior and recovery of polygalacturonase was investigated. Moreover, the effect of pH of system and crude load on purification fold and yield of purified polygalacturonase were studied. The results of the experiment indicated the polygalacturonase was partitioned into surfactant top rich phase with impurities being partitioned into acetonitrile bottom rich phase in the novel method of liquid/liquid process composed of 23% (w/w) Triton X-100 and 19% (w/w) acetonitrile, at 55.6% of TLL (tie line length) crude load of 25% (w/w) at pH 6.0. Recovery and recycling of components also was measured in each successive step of liquid/liquid extraction process. The enzyme was successfully recovered by the method with a high purification factor of 14.3 and yield of 97.3% while phase components were also recovered and recycled above 95%. This study demonstrated that the novel method of liquid/liquid extraction process can be used as an efficient and economical extraction method rather than the traditional methods of extraction for the purification and recovery of the valuable enzyme. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Search for a solvent using the UNIFAC method for separation of coal tar distillate by liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Egashira, R.; Watanabe, K. [Tokyo Institute of Technology, Tokyo (Japan)

    2007-07-01

    Firstly, the functional groups composing the solvent predicted to be appropriate for the separation of coal tar distillate were selected. Secondly, liquid-liquid equilibria between coal tar distillates and solvents containing fictitious components consisting of the above selected functional groups were estimated by UNIFAC to determine the effects of these groups on the distribution coefficients. Finally, according to these results, solvents containing real components were selected and compared. These results provide useful information for the selection of appropriate extracting solvents.

  2. Salting-out assisted liquid/liquid extraction with acetonitrile: a new high throughput sample preparation technique for good laboratory practice bioanalysis using liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Zhang, Jun; Wu, Huaiqin; Kim, Elaine; El-Shourbagy, Tawakol A

    2009-04-01

    Acetonitrile, an organic solvent miscible with aqueous phase, has seen thousands of publications in the literature as an efficient deproteinization reagent. The use of acetonitrile for liquid-liquid extraction (LLE), however, has seen very limited application due to its miscibility with aqueous phase. The interest in LLE with acetonitrile has been pursued and reported in the literature by significantly lowering the temperature of the mixture or increasing the salt concentration in the mixture of acetonitrile and aqueous phase, resulting in the separation of the acetonitrile phase from aqueous phase, as observed in conventional LLE. However, very limited application of these methods has been reported. The throughput was limited. In this report, we report a new sample preparation technique, salting-out assisted liquid-liquid extraction with acetonitrile, for high-throughput good laboratory practice sample analysis using LCMS, Two compounds from an approved drug, Kaletra, were used to demonstrate the extractability of drugs from human plasma matrix. Magnesium sulfate was used as the salting-out reagent. Extracts were diluted and then injected into a reversed phase LC-MS/MS system directly. One 96-well plate was extracted with this new approach to evaluate multiple parameters of a good laboratory practice analytical method. Results indicate that the method is rapid, reliable and suitable for regulated bioanalysis. With minimal modification, this approach has been used for high-throughput good laboratory practice analysis of a number of compounds under development at Abbott.

  3. Liquid-liquid extraction of uranium from nitric acid solution using di-n-butylsulfoxide in petroleum ether as extractant

    Energy Technology Data Exchange (ETDEWEB)

    Khan, M.H.; Shahida, S. [Dept. of Chemistry, Univ. of Azad Jammu and Kashmir, Muzaffarabad (Pakistan); Ali, A. [Nuclear Chemistry Div., Pakistan Inst. of Nuclear Science and Technology, Nilore, Islamabad (Pakistan)

    2008-07-01

    A simple, efficient and economical liquid-liquid extraction method has been developed for quantitative extraction of uranium from 2 M HNO{sub 3} using di-n-butyl sulfoxide in petroleum ether. The dependence of the partition reaction of U(VI) on the concentration of HNO{sub 3}, extractant and temperature was studied. The reaction was found to be inversely dependent upon the temperature and the values for related thermodynamics functions ({delta}H, {delta}S, {delta}G) for extraction equilibrium were determined to be -33.6 kJ/mol, -1.29 kJ/mol/degree and -0.11 kJ/mol/degree, respectively. The effect of Al(NO{sub 3}){sub 3} as salting-out agent and diverse ions on the extraction was examined. The salting-out agent slightly enhanced the extraction. All cations studied have showed negligible effect on the extraction, whereas phosphate and fluoride interfered seriously. Among others, oxalate, citrate and sulphide ions affect the extraction to a lesser extent. Uranium was successfully extracted from a synthetic mixture of Ti{sup +4}, Zr{sup +4}, Hf{sup +4} and Th{sup +4} using EDTA as masking agent. Among strippants, deionized water was found most suitable, and the recovery of uranium was noted to be {>=} 96%. The stoichiometric composition of the extracted species was found to be UO{sub 2}(NO{sub 3}){sub 2} . 2DBSO. The extraction mechanism is discussed on the basis of the results obtained. The extractant has high loading as well as recycling capacity without any degradation. The method was also applied to the Standard Reference Material (NBL-49) and the measured value was found to be in agreement with the reported value within {+-}2% deviation. (orig.)

  4. High-throughput salting-out assisted liquid/liquid extraction and ultrafast LC for same-day delivery of first-in-human bioanalytical data.

    Science.gov (United States)

    Zhang, Jun; Myasein, Francis; Rodila, Ramona; Wu, Huaiqin; El-Shourbagy, Tawakol A

    2009-07-01

    With the need of fast-paced drug development, rapid delivery of bioanalytical data becomes a trend. Here, we present a strategy to demonstrate same-day data delivery. A novel salting-out assisted liquid/liquid extraction (SALLE) with acetonitrile and a MS-friendly salt was used to extract analyte from the first-in-human study plasma samples and the extract was successfully injected into ultrafast chromatography. The strategic combination of SALLE and ultrafast chromatography minimizes the turnaround time and allows the same-day delivery of bioanalytical data. The time saving from both extraction and injection was translated to a fast delivery of bioanalytical data. The first-in-human pharmacokinetic data of an investigational new drug candidate was delivered in approximately 4.5 work h after receiving the samples of each dose group using high-throughput SALLE and ultrafast LC. Incurred sample reassay results proved uncompromised data quality with the high-speed bioanalysis.

  5. Review of algorithms for modeling metal distribution equilibria in liquid-liquid extraction processes

    Directory of Open Access Journals (Sweden)

    Lozano, L. J.

    2005-10-01

    Full Text Available This work focuses on general guidelines to be considered for application of least-squares routines and artificial neural networks (ANN in the estimation of metal distribution equilibria in liquid-liquid extraction process. The goal of the procedure in the statistical method is to find the values of the equilibrium constants (Kj for the reactions involved in the metal extraction which minimizes the differences between experimental distribution coefficient (Dexp and theoretical distribution coefficients according to the mechanism proposed (Dtheor- In the first part of the article, results obtained with the most frequently routine reported in the bibliography are compared with those obtained using the algorithms previously discussed. In the second part, the main features of a single back-propagation neural network for the same purpose are discussed, and the results obtained are compared with those obtained with the classical methods.

    El trabajo presenta las líneas generales a considerar para la estimación del equilibrio de distribución de metales en procesos de extracción líquido-líquido, según dos métodos: algoritmo clásico de mínimos cuadrados y redes neuronales artificiales. El objetivo del procedimiento, en el caso del método estadístico, es encontrar los valores de las constantes de equilibrio (Kj para las reacciones involucradas en la extracción del metal, que minimizan las diferencias entre el coeficiente de distribución experimental y el coeficiente de distribución teórico, de acuerdo al mecanismo propuesto. En la primera parte del artículo se comparan los resultados obtenidos a partir de los algoritmos usados más habitualmente en la bibliografía, con los datos obtenidos mediante el algoritmo previamente descrito. En la segunda parte, se presentan las características fundamentales para aplicar una red neuronal sencilla con algoritmo back-propagation y los

  6. Another glimpse over the salting-out assisted liquid-liquid extraction in acetonitrile/water mixtures.

    Science.gov (United States)

    Valente, Inês Maria; Gonçalves, Luís Moreira; Rodrigues, José António

    2013-09-20

    The use of the salting-out effect in analytical chemistry is very diverse and can be applied to increase the volatility of the analytes in headspace extractions, to cause the precipitation of proteins in biological samples or to improve the recoveries in liquid-liquid extractions. In the latter, the salting-out process can be used to create a phase separation between water-miscible organic solvents and water. Salting-out assisted liquid-liquid extraction (SALLE) is an advantageous sample preparation technique aiming HPLC-UV analysis when developing analytical methodologies. In fact, some new extraction methodologies like QuEChERS include the SALLE concept. This manuscript discusses another point of view over SALLE with particular emphasis over acetonitrile-water mixtures for HPLC-UV analysis; the influence of the salting-out agents, their concentration and the water-acetonitrile volume ratios were the studied parameters. α-dicarbonyl compounds and beer were used as test analytes and test samples, respectively. The influence of the studied parameters was characterized by the obtained phase separation volume ratio and the fraction of α-dicarbonyls extracted to the acetonitrile phase. Results allowed the distribution of salts within three groups according to the phase separation and their extractability: (1) chlorides and acetates, (2) carbonates and sulfates and (3) magnesium sulfate; of all tested salts, sodium chloride had the highest influence on the α-dicarbonyls fraction extracted. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Selective Liquid-Liquid Extraction of Lead Ions Using Newly Synthesized Extractant 2-(Dibutylcarbamoylbenzoic Acid

    Directory of Open Access Journals (Sweden)

    Hossein Soltani

    2015-12-01

    Full Text Available A new carboxylic acid extractant, named 2-(dibutylcarbamoylbenzoic acid, is prepared and its potential for selective solvent extraction and recovery of lead ions from industrial samples was investigated. The slope analysis indicated that the lead ions are extracted by formation of 1:2 metal to ligand complexes. The effect of the parameters influencing the extraction efficiency including kind of the organic diluent, extractant concentration, type of the salt used for ionic strength adjustment, contact time and temperature was evaluated and discussed. Under optimized conditions (aqueous phase: 5 ml, initial lead concentration 1 × 10-4 M, pH 4, sodium chloride 0.1 M; organic phase: 5 ml dichloromethane, ligand concentration 0.05 M, a quantitative (75.2 ± 0.8% and highly selective extraction of lead ions in the presence of zinc, nickel, cobalt and cadmium ions (each 1 × 10-4 M was achieved, after 20 min. magnetically stirring of the phases, at      25 °C. The extracted lead ions were stripped from the organic phase by diluted nitric acid (0.1 M solution. The proposed method was successfully applied for separation of lead from industrial samples. The study of the effect of temperature allowed evaluating the thermodynamic parameters of the extraction process of lead ions by the studied extractant into dichloromethane.

  8. Determination of Zinc Ions in Environmental Samples by Dispersive Liquid- Liquid Micro Extraction and Atomic Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Arabi

    2012-11-01

    Full Text Available In this work preconcentration of the Zn ions was investigated in water sample by Dispersive liquid- liquid micro extraction (DLLME using chloroform as an extraction solvent, methanol as a disperser solvent and 8-Hydroxyquinoline as a chelating agent. The determination of extracted ions was done by graphite furnace atomic absorption spectrometry. The influence of various analytical parameters including pH, extraction and disperser solvent type and volume and concentration of the chelating agent on the extraction efficiency of analyses was investigated. After extraction, the enrichment factor was 26 and the detection limit of the method was 0.0033 µg l-1 and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Zn were 7.41%. 

  9. Acousto-optic tunable filter near-infrared spectroscopy for in-line monitoring liquid-liquid extraction of Gardenia jasminoides Ellis based on statistical analysis.

    Science.gov (United States)

    Wu, Sha; Jin, Ye; Liu, Qi-An; Wu, Jian-Xiong; Bi, Yu-An; Wang, Zhen-Zhong; Xiao, Wei

    2015-10-01

    This study aimed to monitor liquid-liquid extraction of Gardenia jasminoides Ellis (Zhizi in Chinese) using in-line near-infrared spectroscopy. Shanzhiside (SZS), deacetyl asperulosidic acid methyl ester (DAAME), genipin-1-β-D-gentiobioside (GG), geniposide (GS), total acids (TA) and soluble solid content (SSC) were selected as quality control indicators, and measured by reference methods. Both partial least-squares regression (PLSR) and back propagation artificial neural networks (BP-ANN) were applied to create models to predict the content of above indicators. Paired-samples t-test and nonparametric test were used to compare differences in predictive values between two models of each indicator. Relative standard error of prediction (RSEP) and mean absolute percentage error (MAPE) were used to evaluate the predictive accuracy of the established models. The results showed that there was no significant difference in predicting DAAME, GS and TA between two models. However, PLSR model gave better accuracy in predicting GG and SZS than BP-ANN model. The BP-ANN model of SSC was better than PLSR model. This study shows that NIR spectroscopy can be used for rapid and accurate analysis of quality control indicators in the liquid-liquid extraction of Zhizi. Simultaneously, this study can serve as technical support for the application of NIR spectroscopy in the industrial production process.

  10. Miniaturized salting-out liquid-liquid extraction in a coupled-syringe system combined with HPLC-UV for extraction and determination of sulfanilamide.

    Science.gov (United States)

    Sereshti, Hassan; Khosraviani, Marzieh; Sadegh Amini-Fazl, Mohammad

    2014-04-01

    In salting-out liquid-liquid extraction (SALLE) technique, water-miscible organic solvents are used for extraction of polar analytes from saline solutions. In this study, for the first time, a coupled 1-mL syringes system was utilized to perform a miniaturized SALLE method. Sulfanilamide antibiotic was extracted and determined via the developed method followed by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The extraction process was carried out by rapid shooting of acetonitrile as extraction solvent (syringe B) into saline aqueous sample solution (syringe A), and then the shooting was repeated several times at a rate of 1 cycles(-1). Thereby, an extremely large contact surface area was created between phases and led to a rapid equilibrium and mass transfer. In order to improve the efficiency of the method, the effect of extraction solvent (type and volume), shooting times, salt concentration, and pH on the extraction efficiency was investigated. The best performance of the method was achieved with 250 µL of acetonitrile, salt concentration of 250 mg mL(-1), pH of 7, and shooting times of 5. The linear dynamic range was 0.001-10 µg mL(-1) with the determination coefficient of 0.9999. The relative standard deviation (RSD; n=3, C=5 µg mL(-1)), and the limit of detection (LOD) were 1.55% and 0.3 ng mL(-1), respectively. The developed technique was successfully applied to genuine samples of tea, water, milk, honey, human urine, plasma and blood. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. High-throughput liquid-liquid extraction in 96-well format: Parallel artificial liquid membrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Andresen, Alf Terje; Dahlgren, Anders

    2017-01-01

    Parallel artificial liquid membrane extraction (PALME) is a miniaturized version of liquid–liquid extraction (LLE) and is based on two 96-well plates in a sandwich-like configuration. With a very simple workflow, 96 samples can be processed simultaneously in PALME, providing analyte enrichment......, highly efficient sample cleanup, and direct compatibility with liquid chromatography–mass spectrometry (LC–MS). The consumption of hazardous organic solvents is also almost eliminated using PALME as the sample preparation technique. This article summarizes current experiences with PALME, based on work...

  12. Development of a new extraction method based on counter current salting-out homogenous liquid-liquid extraction followed by dispersive liquid-liquid microextraction: Application for the extraction and preconcentration of widely used pesticides from fruit juices.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Feriduni, Behruz; Mogaddam, Mohammad Reza Afshar

    2016-01-01

    In this paper, a new extraction method based on counter current salting-out homogenous liquid-liquid extraction (CCSHLLE) followed by dispersive liquid-liquid microextraction (DLLME) has been developed for the extraction and preconcentration of widely used pesticides in fruit juice samples prior to their analysis by gas chromatography-flame ionization detection (GC-FID). In this method, initially, sodium chloride as a separation reagent is filled into a small column and a mixture of water (or fruit juice) and acetonitrile is passed through the column. By passing the mixture sodium chloride is dissolved and the fine droplets of acetonitrile are formed due to salting-out effect. The produced droplets go up through the remained mixture and collect as a separated layer. Then, the collected organic phase (acetonitrile) is removed with a syringe and mixed with 1,1,2,2-tetrachloroethane (extraction solvent at µL level). In the second step, for further enrichment of the analytes the above mixture is injected into 5 mL de-ionized water placed in a test tube with conical bottom in order to dissolve acetonitrile into water and to achieve a sedimented phase at µL-level volume containing the enriched analytes. Under the optimal extraction conditions (extraction solvent, 1.5 mL acetonitrile; pH, 7; flow rate, 0.5 mL min(-1); preconcentration solvent, 20 µL 1,1,2,2-tetrachloroethane; NaCl concentration; 5%, w/w; and centrifugation rate and time, 5000 rpm and 5 min, respectively), the extraction recoveries and enrichment factors ranged from 87% to 96% and 544 to 600, respectively. Repeatability of the proposed method, expressed as relative standard deviations, ranged from 2% to 6% for intra-day (n=6, C=250 or 500 µg L(-1)) and inter-days (n=4, C=250 or 500 µg L(-1)) precisions. Limits of detection are obtained between 2 and 12 µg L(-1). Finally, the proposed method is applied for the determination of the target pesticide residues in the juice samples. Copyright © 2015

  13. Design, development and testing of miniature liquid-liquid extraction contactors for research-development studies in nuclear environment

    Energy Technology Data Exchange (ETDEWEB)

    Roussel, H.; Charton, S. [CEA Centre de Marcoule, DEN/DTEC/SGCS, F-30207 Bagnols-sur-Ceze (France)

    2016-07-01

    Testing liquid-liquid extraction flowsheets on radioactive solutions at laboratory scale requires specific contactors, that must be as small as possible (to minimize the quantities of reagents) and suitable for use in glove boxes or hot cells. As such contactors are not commercially available, CEA designs dedicated apparatus for its experiments. Two examples of such contactors are highlighted: a stage-wise one (a miniature mixer-settler) and a differential one (the Taylor-Couette column). Both combine similarities with larger contactors that make possible flowsheet extrapolation to industrial scale, and specific features, mainly because of the major role of materials wettability when volumes are reduced. (authors)

  14. Recovery of zinc and manganese from spent alkaline batteries by liquid-liquid extraction with Cyanex 272

    Science.gov (United States)

    Salgado, Aline L.; Veloso, Aline M. O.; Pereira, Daniel D.; Gontijo, Glayson S.; Salum, Adriane; Mansur, Marcelo B.

    A hydrometallurgical route based on the liquid-liquid extraction technique using Cyanex 272 as extractant is investigated for the selective separation of metal values, in particular, zinc and manganese from spent alkaline batteries. The recycling route consists of following steps: (1) cryogenic dismantling of the spent batteries, (2) pre-treatment of the internal material consisting of drying, grinding and screening steps in order to produce a dry homogeneous powder, (3) leaching of the powder with sulphuric acid and (4) metal separation by liquid-liquid extraction. Bench scale experiments have shown that zinc and manganese are easily separated (ΔpH 1/2≈2.0) using 20% (v/v) Cyanex 272 dissolved in Escaid 110 at 50 °C. Therefore, the proposed route can treat residues from both zinc-carbon and alkaline batteries because metal composition of these batteries is quite similar. The metal content of other batteries such as Ni-Cd and nickel-metal hydride (NiMH) has been also determined in order to include them in future investigations.

  15. [Determination of levamisole residue in animal livers by two liquid-liquid extraction steps-gas chromatography-mass spectrometry].

    Science.gov (United States)

    Xu, Jing; Xiao, Shanshan; Dong, Weifeng; Sui, Kai; Cao, Jijuan; Diao, Wenting; Zhang, Jing

    2012-09-01

    A novel method wasdeveloped for the determination oflevamisole in animal livers by liquid-liquid extraction and gas chromatography-mass spectrometry. Levamisole hydrochloride was transferred to levamisole in alkalinesolution, andthen extracted intoethyl acetate. Two liquid-liquid extraction steps were carried out with HCI aqueous solution and potassium hydroxide-dichloromethane system in turn, and the liposoluble substances and the water-soluble substances were removed, respectively. The qualitative and quantitative analyses of levamisole were achieved by gas chromatography-mass spectrometry (GC-MS) system. The characteristic fragments m/z 148, 176 and 204 were selected and m/z 204 was used as the quantitative ion. A good linear relationship was obtained between the peak area and the mass concentration of levamisole from 0.25 mg/L to 3.0 mg/L with the correlation coefficient of 0.999. The limit of quantitation (LOQ) for levamisole was 5 microg/kg, which was much lower than the international maximum residue limit. The average recoveries of levamisole spiked in chicken liver, duck liver, rabbit liver and pig liver samples at three spiked levels ranged from 76% to 106% with the relative standard deviations less than 9%. The method is simple and stable without tedious sample preparation, and suitable for the determination of levamisole in animal livers.

  16. Exploring bubble oscillation and mass transfer enhancement in acoustic-assisted liquid-liquid extraction with a microfluidic device

    Science.gov (United States)

    Xie, Yuliang; Chindam, Chandraprakash; Nama, Nitesh; Yang, Shikuan; Lu, Mengqian; Zhao, Yanhui; Mai, John D.; Costanzo, Francesco; Huang, Tony Jun

    2015-01-01

    We investigated bubble oscillation and its induced enhancement of mass transfer in a liquid-liquid extraction process with an acoustically-driven, bubble-based microfluidic device. The oscillation of individually trapped bubbles, of known sizes, in microchannels was studied at both a fixed frequency, and over a range of frequencies. Resonant frequencies were analytically identified and were found to be in agreement with the experimental observations. The acoustic streaming induced by the bubble oscillation was identified as the cause of this enhanced extraction. Experiments extracting Rhodanmine B from an aqueous phase (DI water) to an organic phase (1-octanol) were performed to determine the relationship between extraction efficiency and applied acoustic power. The enhanced efficiency in mass transport via these acoustic-energy-assisted processes was confirmed by comparisons against a pure diffusion-based process. PMID:26223474

  17. Optimization of alcohol-assisted dispersive liquid-liquid microextraction by experimental design for the rapid determination of fluoxetine in biological samples.

    Science.gov (United States)

    Hamedi, Raheleh; Hadjmohammadi, Mohammad Reza

    2016-12-01

    A sensitive and rapid method based on alcohol-assisted dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for the determination of fluoxetine in human plasma and urine samples was developed. The effects of six parameters on the extraction recovery were investigated and optimized utilizing Plackett-Burman design and Box-Benken design, respectively. According to the Plackett-Burman design results, the volume of disperser solvent, extraction time, and stirring speed had no effect on the recovery of fluoxetine. The optimized conditions included a mixture of 172 μL of 1-octanol as extraction solvent and 400 μL of methanol as disperser solvent, pH of 11.3 and 0% w/v of salt in the sample solution. Replicating the experiment in optimized condition for five times, gave the average extraction recoveries equal to 90.15%. The detection limit of fluoxetine in human plasma was obtained 3 ng/mL, and the linearity was in the range of 10-1200 ng/mL. The corresponding values for human urine were 4.2 ng/mL with the linearity range from 10 to 2000 ng/mL. Relative standard deviations for intra and inter day extraction of fluoxetine were less than 7% in five measurements. The developed method was successfully applied for the determination of fluoxetine in human plasma and urine samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Liquid-liquid extraction of ion-association complexes of cobalt(II-4-(2-pyridylazoresorcinol with ditetrazolium salts

    Directory of Open Access Journals (Sweden)

    Divarova Vidka V.

    2015-01-01

    Full Text Available The formation and liquid-liquid extraction of ion-association complexes between Co(II-4-(2-Pyridylazoresorcinol (PAR anionic chelates and cations of three ditetrazolium chlorides were studied: Blue Tetrazolium chloride (BTC, Neotetrazolium chloride (NTC and Nitro Blue Tetrazolium chloride (NBT. The optimum conditions for the formation and solvent extraction of the ion-association comlpex chelates were determined. It has been found that in the systems of Co(II-PAR-DTS, the reactants are reacted in molar ratios 1:2:1 and the general formula of complexes was suggested. The extraction equilibria were investigated and quantitatively characterized by the equilibrium constants and the recovery factors. The analytical characteristics of the complexes were calculated.

  19. Ultrasound-assisted low-density solvent dispersive liquid-liquid extraction for the determination of alkanolamines and alkylamines in cosmetics with ion chromatography.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke; Zhong, Xiuhua; Luo, Zhibin; Zhu, Binghui

    2013-10-15

    A new one-step sample preparation technique termed ultrasound-assisted low-density solvent dispersive liquid-liquid extraction (UA-LDS-DLLE) coupled with ion chromatography (IC) was developed for the determination of three alkanolamines and two alkylamines in complex samples. Sample matrices were rapidly dissolved and dispersed to form cloudy solutions by using two solvents, where target analytes were transferred into acid solutions, while liposoluble substances were dissolved in cyclohexane. The obtained extracts could be used directly for injection analysis without any additional purification because the potential matrix interferences had been effectively eliminated in extraction process. The extraction efficiency could be markedly enhanced and the extraction could be quickly accomplished within 13 min under the synergistic effects of ultrasound radiation, vibration and heating. Various parameters influencing extraction efficiency were evaluated using orthogonal array experimental design. The extraction performance of the approach was demonstrated for the determination of target analytes in 15 commercial cosmetics covering very different matrices. Linearity ranges of 0.3-50 mg L(-1) and limits of detection varying from 0.072 to 0.12 mg L(-1) were achieved. The recoveries ranged from 86.9-108.5% with the relative standard deviations (RSDs) of 1.2-6.2%. The method was proved to be a simple and effective extraction technique that provided an attractive alternative to the analysis of trace amounts of target analytes in large numbers of cosmetics. Copyright © 2013. Published by Elsevier B.V.

  20. Effectiveness of Liquid-Liquid Extraction, Solid Phase Extraction, and Headspace Technique for Determination of Some Volatile Water-Soluble Compounds of Rose Aromatic Water

    Science.gov (United States)

    2017-01-01

    Steam distillation is used to isolate scent of rose flowers. Rose aromatic water is commonly used in European cuisine and aromatherapy besides its use in cosmetic industry for its lovely scent. In this study, three different sampling techniques, liquid-liquid extraction (LLE), headspace technique (HS), and solid phase extraction (SPE), were compared for the analysis of volatile water-soluble compounds in commercial rose aromatic water. Some volatile water-soluble compounds of rose aromatic water were also analyzed by gas chromatography mass spectrometry (GCMS). In any case, it was concluded that one of the solid phase extraction methods led to higher recoveries for 2-phenylethyl alcohol (PEA) in the rose aromatic water than the liquid-liquid extraction and headspace technique. Liquid-liquid extraction method provided higher recovery ratios for citronellol, nerol, and geraniol than others. Ideal linear correlation coefficient values were observed by GCMS for quantitative analysis of volatile compounds (r2 ≥ 0.999). Optimized methods showed acceptable repeatability (RSDs 95%). For compounds such as α-pinene, linalool, β-caryophyllene, α-humulene, methyl eugenol, and eugenol, the best recovery values were obtained with LLE and SPE. PMID:28791049

  1. Determination of trace levels of dinitrophenolic compounds by microporous membrane liquid-liquid extraction in environmental water samples.

    Science.gov (United States)

    Bartolomé, Luis; Lezamiz, Jon; Etxebarria, Néstor; Zuloaga, Olatz; Jönsson, Jan Ake

    2007-08-01

    A fast and simple hollow fibre-based microporous membrane liquid-liquid extraction (MMLLE) method is proposed for the determination of trace levels of dinitrophenolic compounds in water samples. The optimization step was performed using a three-variables Doehlert matrix design, involving the fibre length, the quantity of trioctylphosphine oxide (TOPO) in the acceptor phase and the extraction time. Using the established experimental conditions, some other parameters such as stirring speed, salt content, humic acids and different organic solvents as the acceptor phase were studied. Validation of the method included calibration experiments, linearity studies and determination of method LOD (MLD). The RSD was around 11% in all the experiments on different days at different concentrations. Separation and detection of four dinitrophenols were performed in 10 min with an RP-LC and a C(8 )column ACN-citric buffer gradient elution and diode array detection.

  2. RECOVERY OF CARBOXYLIC ACIDS FROM AQUEOUS SOLUTIONS BY LIQUID-LIQUID EXTRACTION WITH A TRIISOOCTYLAMINE DILUENT SYSTEM

    Directory of Open Access Journals (Sweden)

    G. Malmary

    2001-12-01

    Full Text Available Tertiary alkylamines in solution with organic diluents are attractive extractants for the recovery of carboxylic acids from dilute aqueous phases. The aim of this study was to investigate the mechanism for extraction of organic acids from water by a long-chain aliphatic tertiary amine. In order to attain this objective, we studied the liquid-liquid equilibria between the triisooctylamine + 1-octanol + n-heptane system as solvent and an aqueous solution of an individual carboxylic acid such as citric, lactic and malic acids. The experiments showed that the partition coefficient for a particular organic acid depends on the kind of solute, notably when the acid concentration in the aqueous phase is low. A mathematical model, where both chemical association and physical distribution are taken into consideration, is proposed. The model suggests that the various complexes obtained between amine and organic acids contribute to the distribution of the solute between the coexisting phases in equilibrium.

  3. Recovery of Scandium from Leachate of Sulfation-Roasted Bayer Red Mud by Liquid-Liquid Extraction

    Science.gov (United States)

    Liu, Zhaobo; Li, Hongxu; Jing, Qiankun; Zhang, Mingming

    2017-11-01

    The leachate obtained from sulfation-roasted Bayer red mud is suitable for extraction of scandium by liquid-liquid solvent extraction because it contains trace amounts of Fe3+ and Si4+. In this study, a completely new metallurgical process for selective recovery of scandium from Bayer red mud was proposed. The extraction performances of Sc3+, Fe3+, Al3+, Si4+, Ca2+, and Na+ from synthetic leachate of sulfation-roasted red mud were first investigated using organophosphorus extractants (di-2-ethylhexyl phosphoric acid P204 and 2-ethylhexyl phosphoric acid mono-2-ethylhexyl ester P507) and carboxylic acid extractant (Versatic acid 10). It shows that P204 has an excellent extraction ability and that it can be applied to the scandium recovery. P507 and Versatic acid 10 are much poorer in performance for selective extraction of scandium. In the leachate of sulfation-roasted red mud, approximately 97% scandium can be recovered using a P204/sulfonated kerosene (1% v/v) extraction system under the condition of an organic-to-aqueous phase ratio of 10:1 and with an extraction temperature of 15°C.

  4. Determination of parabens in human milk and other food samples by capillary electrophoresis after dispersive liquid-liquid microextraction with back-extraction.

    Science.gov (United States)

    Alshana, Usama; Ertaş, Nusret; Göğer, Nilgün G

    2015-08-15

    Dispersive liquid-liquid microextraction (DLLME) with back-extraction was used prior to capillary electrophoresis (CE) for the extraction of four parabens. Optimum extraction conditions were: 200 μL chloroform (extraction solvent), 1.0 mL acetonitrile (disperser solvent) and 1 min extraction time. Back-extraction of parabens from chloroform into a 50mM sodium hydroxide solution within 10s facilitated their direct injection into CE. The analytes were separated at 12°C and 25 kV with a background electrolyte of 25 mM borate buffer containing 5.0% (v/v) acetonitrile. Enrichment factors were in the range of 4.3-10.7 and limits of detection ranged from 0.1 to 0.2 μg mL(-1). Calibration graphs showed good linearity with coefficients of determination (R(2)) higher than 0.9957 and relative standard deviations (%RSDs) lower than 3.5%. DLLME-CE was demonstrated to be a simple and rapid method for the determination of parabens in human milk and food with relative recoveries in the range of 86.7-103.3%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Kinetic of liquid-liquid extraction for uranyl nitrate and actinides (III) and lanthanides (III) nitrates by amide extractants; Cinetique d`extraction liquide-liquide du nitrate d`uranyle et des nitrates d`actinides (III) et de lanthanides (III) par des extractants a fonction amide

    Energy Technology Data Exchange (ETDEWEB)

    Toulemonde, V. [CEA Centre d`Etudes Nucleaires de Saclay, 91 -Gif-sur-Yvette (France)]|[CEA Centre d`Etudes de la Vallee du Rhone, 30 -Marcoule (France). Dept. d`Exploitation du Retraitement et de Demantelement

    1995-12-20

    The kinetics of liquid-liquid extraction by amide extractants have been investigated for uranyl nitrate (monoamide extractants), actinides (III) and lanthanides (III) nitrates (diamide extractants). The transfer of the metallic species from the aqueous phase to the organic phase was studied using two experimental devices: ARMOLLEX (Argonne Modified Lewis cell for Liquid Liquid Extraction) and RSC (Rotating Stabilized Cell). The main conclusions are: for the extraction of uranyl nitrate by DEHDMBA monoamide, the rate-controlling step is the complexation of the species at the interface of the two liquids. Thus, an absorption-desorption (according to Langmuir theory) reaction mechanism was proposed; for the extraction of actinides (III) and lanthanides (III) nitrates in nitric acid media by DMDBTDMA diamide, the kinetic is also limited by interfacial reactions. The behavior of Americium and Europium is very similar as fare as their reaction kinetics are concerned. (author). 89 refs.

  6. Novel method for determination of anthracene by coupling dispersive liquid-liquid extraction to first-derivative synchronous spectrofluorimetry.

    Science.gov (United States)

    Abdel-Aziz, Omar; El Kosasy, A M; El-Sayed Okeil, Sherif Mahmoud

    2014-05-01

    A novel method could be adopted successfully for determination of anthracene in environmental samples, utilizing dispersive liquid-liquid extraction followed by first-derivative synchronous fluorimetry at a constant wavelength difference Δλ = 165 nm, where a linear calibration curve was obtained in a concentration range of 0.5-100 ng mL(-1) at 244 nm. The detection limit was 0.1 ng mL(-1). The method can be easily adopted for determination of anthracene in aqueous media including tap water and river water. The recoveries obtained were 85.40-108.02%. The proposed method was validated according to International Conference of Harmonization (ICH) guide lines and successfully applied to determine anthracene in pure form and in water samples including real life water samples from different sources. All the results obtained were compared with those of published method, where no a significant difference was observed.

  7. Liquid-liquid extraction of iron (III) from Ouenza iron ore leach liquor ...

    African Journals Online (AJOL)

    The stoichiometry of the extracted species was determined by using the method of slope analysis. The number of moles of H+, Cl- and TBP associated with the extracted species was determined and the extracted species was found to be HFeCl4 (TBP)2. Keywords: solvent extraction; iron (III); Tributylphosphate; leach liquor; ...

  8. Optimization and validation of liquid-liquid extraction with low temperature partitioning for determination of carbamates in water

    Energy Technology Data Exchange (ETDEWEB)

    Machado Goulart, Simone; Domingos Alves, Renata; Neves, Antonio Augusto; Queiroz, Jose Humberto de; Conde de Assis, Tamires [Departamento de Quimica, Universidade Federal de Vicosa, Vila Gianetti, Casa 24, 36 570-000 Vicosa, MG (Brazil); Queiroz, Maria Eliana L.R. de, E-mail: meliana@ufv.br [Departamento de Quimica, Universidade Federal de Vicosa, Vila Gianetti, Casa 24, 36 570-000 Vicosa, MG (Brazil)

    2010-06-25

    Using a 2{sup 3} experimental design, liquid-liquid extraction with low temperature partitioning (LLE-LTP) was optimized and validated for analysis of three carbamates (aldicarb, carbofuran and carbaryl) in water samples. In this method, 2.0 mL of sample is placed in contact with 4.0 mL of acetonitrile. After agitation, the sample is placed in a freezer for 3 h for phase separation. The organic extract is analyzed by high performance liquid chromatography with ultraviolet detection (HPLC-UV). For validation of the technique, the following figures of merit were evaluated: accuracy, precision, detection and quantification limits, linearity, sensibility and selectivity. Extraction recovery percentages of the carbamates aldicarb, carbofuran and carbaryl were 90%, 95% and 96%, respectively. Even though extremely low volumes of sample and solvent were used, the extraction method was selective and the detection and quantification limits were between 5.0 and 10.0 {mu}g L{sup -1}, and 17.0 and 33.0 {mu}g L{sup -1}, respectively.

  9. Optimization and validation of liquid-liquid extraction with low temperature partitioning for determination of carbamates in water.

    Science.gov (United States)

    Goulart, Simone Machado; Alves, Renata Domingos; Neves, Antônio Augusto; de Queiroz, José Humberto; de Assis, Tamires Condé; de Queiroz, Maria Eliana L R

    2010-06-25

    Using a 2(3) experimental design, liquid-liquid extraction with low temperature partitioning (LLE-LTP) was optimized and validated for analysis of three carbamates (aldicarb, carbofuran and carbaryl) in water samples. In this method, 2.0 mL of sample is placed in contact with 4.0 mL of acetonitrile. After agitation, the sample is placed in a freezer for 3 h for phase separation. The organic extract is analyzed by high performance liquid chromatography with ultraviolet detection (HPLC-UV). For validation of the technique, the following figures of merit were evaluated: accuracy, precision, detection and quantification limits, linearity, sensibility and selectivity. Extraction recovery percentages of the carbamates aldicarb, carbofuran and carbaryl were 90%, 95% and 96%, respectively. Even though extremely low volumes of sample and solvent were used, the extraction method was selective and the detection and quantification limits were between 5.0 and 10.0 microg L(-1), and 17.0 and 33.0 microg L(-1), respectively. Copyright 2010 Elsevier B.V. All rights reserved.

  10. In situ liquid-liquid extraction as a sample preparation method for matrix-assisted laser desorption/ionization MS analysis of polypeptide mixtures

    DEFF Research Database (Denmark)

    Kjellström, Sven; Jensen, Ole Nørregaard

    2003-01-01

    A novel liquid-liquid extraction (LLE) procedure was investigated for preparation of peptide and protein samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). LLE using ethyl acetate as the water-immiscible organic solvent enabled segregation of hydrophobic...

  11. Ultrasonic nebulization extraction assisted dispersive liquid-liquid microextraction followed by gas chromatography for the simultaneous determination of six parabens in cosmetic products.

    Science.gov (United States)

    Wei, Hongmin; Yang, Jinjuan; Zhang, Hanqi; Shi, Yuhua

    2014-09-01

    A simple, rapid, and efficient method of ultrasonic nebulization extraction assisted dispersive liquid-liquid microextraction was developed for the simultaneous determination of six parabens in cosmetic products. The analysis was carried out by gas chromatography. Water was used as the dispersive solvent instead of traditional organic disperser. The experimental factors affecting the extraction yield, such as the extraction solvent and volume, extraction time, dispersive solvent and volume, ionic strength, and centrifuging condition were studied and optimized in detail. The limit of detections for the target analytes were in the range of 2.0-9.5 μg/g. Good linear ranges were obtained with the coefficients ranging from 0.9934 to 0.9969. The proposed method was successfully applied to the analysis of six parabens in 16 cosmetic products. The recoveries of the target analytes in real samples ranged from 81.9 to 108.7%, and the relative standard deviations were <5.3%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Ultrasound assisted dispersive liquid-liquid microextraction followed by injector port silylation: a novel method for rapid determination of quinine in urine by GC-MS.

    Science.gov (United States)

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Ch, Ratnasekhar; Chauhan, Abhishek; Khan, Haider A; Murthy, Rc

    2013-09-01

    Silylation is a widely used derivatization method for the analysis of polar analytes by GC-MS. Ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) is an ecofriendly, rapid and simple microextraction method. For the first time, a novel approach has been developed and applied for the analysis of quinine in urine by combining UA-DLLME with injection port silylation. The LOD and LOQ were found to be 5.4 and 18 ng/ml. The intra- and inter-day precisions were less than 5 and 8%, respectively. Mean recoveries of quinine were found to be in the range of 87 to 96%. Ultrasound-assisted dispersive liquid-liquid microextraction is rapid, simple and consumes less reagent for the analysis of polar analytes such as quinine.

  13. Highly efficient enantioselective liquid-liquid extraction of 1,2-amino-alcohols using SPINOL based phosphoric acid hosts.

    Science.gov (United States)

    Pinxterhuis, Erik B; Gualtierotti, Jean-Baptiste; Heeres, Hero J; de Vries, Johannes G; Feringa, Ben L

    2017-09-01

    Access to enantiopure compounds on large scale in an environmentally friendly and cost-efficient manner remains one of the greatest challenges in chemistry. Resolution of racemates using enantioselective liquid-liquid extraction has great potential to meet that challenge. However, a relatively feeble understanding of the chemical principles and physical properties behind this technique has hampered the development of hosts possessing sufficient resolving power for their application to large scale processes. Herein we present, employing the previously untested SPINOL based phosphoric acids host family, an in depths study of the parameters affecting the efficiency of the resolution of amino-alcohols in the optic of further understanding the core principles behind ELLE. We have systematically investigated the dependencies of the enantioselection by parameters such as the choice of solvent, the temperature, as well as the pH and bring to light many previously unsuspected and highly intriguing interactions. Furthermore, utilizing these new insights to our advantage, we developed novel, highly efficient, extraction and resolving protocols which provide remarkable levels of enantioselectivity. It was shown that the extraction is catalytic in host by demonstrating transport in a U-tube and finally it was demonstrated how the solvent dependency could be exploited in an unprecedented triphasic resolution system.

  14. Isolation of atropine and scopolamine from plant material using liquid-liquid extraction and EXtrelut® columns.

    Science.gov (United States)

    Śramska, Paula; Maciejka, Artur; Topolewska, Anna; Stepnowski, Piotr; Haliński, Łukasz P

    2017-02-01

    Tropane alkaloids are toxic secondary metabolites produced by Solanaceae plants. Among them, plants from Datura genus produce significant amounts of scopolamine and hyoscyamine; the latter undergoes racemization to atropine during isolation. Because of their biological importance, toxic properties and commonly reported food and animal feed contamination by different Datura sp. organs, there is a constant need for reliable methods for the analysis of tropane alkaloids in many matrices. In the current study, three extraction and sample-clean up procedures for the determination of scopolamine and atropine in plant material were compared in terms of their effectiveness and repeatability. Standard liquid-liquid extraction (LLE) and EXtrelut® NT 3 columns were used for the sample clean-up. Combined ultrasound-assisted extraction and 24h static extraction using ethyl acetate, followed by multiple LLE steps was found the most effective separation method among tested. However, absolute extraction recovery was relatively low and reached 45-67% for atropine and 52-73% for scopolamine, depending on the compound concentration. The same method was also the most effective one for the isolation of target compounds from Datura stramonium leaves. EXtrelut® columns, on the other hand, displayed relatively low effectiveness in isolating atropine and scopolamine from such a complex matrix and hence could not be recommended. The most effective method was also applied to the extraction of alkaloids from roots and stems of D. stramonium. Quantitative analyses were performed using validated method based on gas chromatography with flame ionization detector (GC-FID). Based on the results, the importance of the proper selection of internal standards in the analysis of tropane alkaloids was stressed out. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Composite hollow fiber membranes for organic solvent-based liquid-liquid extraction

    NARCIS (Netherlands)

    He, T.; Bolhuis-Versteeg, Lydia A.M.; Mulder, M.H.V.; Wessling, Matthias

    2004-01-01

    Instability issues of liquid membranes extraction significantly limit its wide application in industry. We report research on the application of a new composite hollow fiber membrane to stabilizing liquid membrane extraction. These type of composite membranes have either a polysulfone (PSf)

  16. Liquid - liquid extraction of matrine using TRPO/cyclohexane reverse micelles

    Directory of Open Access Journals (Sweden)

    Lichun Dong

    2009-06-01

    Full Text Available Reverse micellar extraction has been widely used in the purification of biomolecules. However, reverse micelles formed by ionic surfactants can only be employed for the extraction of biomolecules that are charged in the extraction system with the electrostatic interaction between surfactants and solutes as the driving force. In this study, the extraction of matrine by using reverse micelles formed by non-ionic TRPO surfactants was studied. Theoretical analysis and experimental results demonstrated that the driving force of the extraction is the coordination forces between matrines and TRPOs. Using this coordination-based reverse micellar extraction, matrine can be efficiently separated from oxymatrine and other components in the raw matrine materials. Experimental studies showed that the factors affecting matrine extraction include pH value and TRPO concentration. The existence of ions in the system does not affect the partition coefficient significantly and the addition of a small amount of chloroform in the solution of reverse micelles was found to improve the extraction significantly.

  17. Liquid-liquid extraction of palladium(II) from nitric acid by bis(2-ethylhexyl) sulphoxide

    Energy Technology Data Exchange (ETDEWEB)

    Shukla, J.P. (Radiochemistry Division, Bhabha Atomic Research Centre, Trombay, Bombay 400085 (India)); Singh, R.K.; Sawant, S.R.; Varadarajan, N. (Power Reactor Fuel Reprocessing Plant, Bhabha Atomic Research Centre, Trombay, Bombay 400085 (India))

    1993-04-15

    The extraction of palladium(II) nitrate by bis(2-ethylhexyl) sulphoxide (BESO) was evaluated over a wide range of acidity, and BESO was shown to have a strong extraction ability toward this thiophilic 'soft' metal. Essentially quantitative extraction of trace and macro amounts of palladium is easily accomplished from about 8 M HNO 8 M HNO[sub 3] down to pH 2 solutions by 0.2 M BESO into toluene. Optimum conditions such as aqueous phase acidity, solvent, period of equilibration, aqueous to organic phase ratios, reagent concentration and strippant were established for the selective and reversible extraction and separation of palladium. Slope analyses applied to Pd(II) distribution experiments from nitrate solutions showed a predominant formation of the solvated organic phase complex Pd(NO[sub 3])[sub 2].2BESO. Recovery of the extractant from loaded palladium is easily accomplished by using sodium thiosulphate or a mixture of 2 M sodium carbonate+0.5 M ammonia solution. The extracted complex was characterized by elemental analysis and IR and UV-visible spectrometry, and its composition was confirmed to be Pd(NO[sub 3])[sub 2].2BESO

  18. Optimisation of the liquid-liquid extraction of soybean oil using a binary mixture1

    Directory of Open Access Journals (Sweden)

    Glêndara Aparecida de Souza Martins

    Full Text Available The soybean has been widely studied due to its constituents and to their application. Authors have pointed out that its composition can vary, with its use frequently taking the form of oil. The oil extraction process, which is in constant application in the market, consists of the use of extraction solvents, with hexane being one of the most used; however the fact that this comes from non-renewable sources has aroused interest in its replacement. As a result, ethanol has been seen as an alternative solvent, despite increasing the cost of the process. This study therefore aims to evaluate the composition of three soybean cultivars planted in the region of Palmas, in the state of Tocantins, Brazil, and to optimise oil extraction from the beans through the use of a binary mixture of ethanol and hexane. The cultivars displayed high protein and lipid potential. The extraction time and temperature proved influential in the process. Ethanol, when present in greater quantity in the mixture, with an increase in temperature, caused an increase in the levels of extracted oil.

  19. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    Science.gov (United States)

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. High-Throughput Determination of Sodium Danshensu in Beagle Dogs by the LCMS/MS Method, Employing Liquid-Liquid Extraction Based on 96-Well Format Plates.

    Science.gov (United States)

    Jiang, Jingjing; Zhao, Xin; Li, Xiuxiu; Wu, Shengyuan; Yu, Shidan; Lou, Yuefen; Fan, Guorong

    2017-04-25

    Sodium Danshensu (sodium d-(+)-β-(3,4-dihydroxyphenyl) lactate), one of the water-soluble ingredients in Salvia miltiorrhiza , exhibits potent relaxation of the coronary artery and anticoagulation effection. A high-throughput, rapid, and sensitive method combining liquid chromatography with electrospray ionization tandem mass spectrometry to determine the sodium danshensu in beagle dog plasma was developed and validated, using gallic acid as an internal standard (IS). Acidified plasma samples were extracted using 96-well liquid-liquid extraction, and were eluted on a CNW Athena C18 column (3 μm, 2.1 × 100 mm) by using a gradient mobile phase system of methanol and water (containing 0.2% formic acid). The mass spectrometric detection was achieved using negative ion electrospray ionization mode and monitoring the precursor→production combinations of m / z 197→135 for sodium danshensu and 169→125 for IS, in multiple reaction monitoring modes. Good linearity was achieved, and the linear range was 10-1000 ng/mL (R² > 0.996) with a quantification limit of 10 ng/mL for sodium danshensu in beagle dog plasma. The intra- and inter-day precision (RSD) ranged from 2.1% to 9.0%. The accuracy (RE) was between -8.6% and 5.7% at all quality control levels. The validated method was successfully applied to the pharmacokinetics study of sodium danshensu in beagle dog plasma after intravenous injection and oral administration of sodium danshensu.

  1. Simultaneous Distillation Extraction of Some Volatile Flavor Components from Pu-erh Tea Samples—Comparison with Steam Distillation-Liquid/Liquid Extraction and Soxhlet Extraction

    Science.gov (United States)

    Gu, Xungang; Zhang, Zhengzhu; Wan, Xiaochun; Ning, Jingming; Yao, Chengcheng; Shao, Wanfang

    2009-01-01

    A simutaneous distillation extraction (SDE) combined GC method was constructed for determination of volatile flavor components in Pu-erh tea samples. Dichloromethane and ethyl decylate was employed as organic phase in SDE and internal standard in determination, respectively. Weakly polar DB-5 column was used to separate the volatile flavor components in GC, 10 of the components were quantitatively analyzed, and further confirmed by GC-MS. The recovery covered from 66.4%–109%, and repeatability expressed as RSD was in range of 1.44%–12.6%. SDE was most suitable for the extraction of the anlytes by comparing with steam distillation-liquid/liquid extraction and Soxhlet extraction. Commercially available Pu-erh tea samples, including Pu-erh raw tea and ripe tea, were analyzed by the constructed method. the high-volatile components, such as benzyl alcohol, linalool oxide, and linalool, were greatly rich in Pu-erh raw teas, while the contents of 1,2,3-Trimethoxylbenzene and 1,2,4-Trimethoxylbenzene were much high in Pu-erh ripe teas. PMID:20169174

  2. Solvent Extraction: Structure of the Liquid-Liquid Interface Containing a Diamide Ligand

    Energy Technology Data Exchange (ETDEWEB)

    Scoppola, Ernesto [Institut Laue-Langevin, 38000 Grenoble France; Institut de Chimie Séparative de Marcoule, UMR 5257 CEA/CNRS/ENSCM/Université Montpellier, 30207 Bagnols-sur-Cèze France; Watkins, Erik B. [Institut Laue-Langevin, 38000 Grenoble France; Materials Synthesis and Integrated Devices, Los Alamos National Laboratory, Los Alamos NM 87545 USA; Campbell, Richard A. [Institut Laue-Langevin, 38000 Grenoble France; Konovalov, Oleg [European Synchrotron Radiation Facility, 38430 Grenoble France; Girard, Luc [Institut de Chimie Séparative de Marcoule, UMR 5257 CEA/CNRS/ENSCM/Université Montpellier, 30207 Bagnols-sur-Cèze France; Dufrêche, Jean-Francois [Institut de Chimie Séparative de Marcoule, UMR 5257 CEA/CNRS/ENSCM/Université Montpellier, 30207 Bagnols-sur-Cèze France; Ferru, Geoffroy [Argonne National Labororatory, Lemont IL 60439 USA; Fragneto, Giovanna [Institut Laue-Langevin, 38000 Grenoble France; Diat, Olivier [Institut de Chimie Séparative de Marcoule, UMR 5257 CEA/CNRS/ENSCM/Université Montpellier, 30207 Bagnols-sur-Cèze France

    2016-06-20

    Knowledge of the (supra)molecular structure of an interface that contains amphiphilic ligand molecules is necessary for a full understanding of ion transfer during solvent extraction. Even if molecular dynamics already yield some insight in the molecular configurations in solution, hardly any experimental data giving access to distributions of both extractant molecules and ions at the liquid–liquid interface exist. Here, the combined application of X-ray and neutron reflectivity measurements represents a key milestone in the deduction of the interfacial structure and potential with respect to two different lipophilic ligands. Indeed, we show for the first time that hard trivalent cations can be repelled or attracted by the extractant-enriched interface according to the nature of the ligand.

  3. OPTIMIZED DETERMINATION OF TRACE JET FUEL VOLATILE ORGANIC COMPOUNDS IN HUMAN BLOOD USING IN-FIELD LIQUID-LIQUID EXTRACTION WITH SUBSEQUENT LABORATORY GAS CHROMATOGRAPHIC-MASS SPECTROMETRIC ANALYSIS AND ON-COLUMN LARGE VOLUME INJECTION

    Science.gov (United States)

    A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing te...

  4. liquid-liquid extraction of iron (iii) from ouenza iron ore leach liquor

    African Journals Online (AJOL)

    A. Nouioua

    2017-09-01

    Sep 1, 2017 ... The effect of several parameters, such as contact time, HCl concentration, TBP concentration and chloride inorganic salt (KCl) concentration on the efficiency of ... the extraction is described by the following equilibrium: ... [TBP] = 1M, [HCl] = 5M, [KCl] = 2M, ratio (O / A) 1:1, stirring rate 300 rpm and reaction.

  5. Rapid determination of 9 aromatic amines in mainstream cigarette smoke by modified dispersive liquid liquid microextraction and ultraperformance convergence chromatography tandem mass spectrometry.

    Science.gov (United States)

    Deng, Huimin; Yang, Fei; Li, Zhonghao; Bian, Zhaoyang; Fan, Ziyan; Wang, Ying; Liu, Shanshan; Tang, Gangling

    2017-07-21

    Aromatic amines in mainstream cigarette smoke have long been monitored due to their carcinogenic toxicity. In this work, a reliable and rapid method was developed for the simultaneous determination of 9 aromatic amines in mainstream cigarette smoke by modified dispersive liquid liquid microextraction (DLLME) and ultraperformance convergence chromatography tandem mass spectrometry (UPC2-MS/MS). Briefly, the particulate phase of the cigarette smoke was captured by a Cambridge filter pad, and diluted hydrogen chloride aqueous solution is employed to extract the aromatic amines under mechanical shaking. After alkalization with sodium hydroxide solution, small amount of toluene was introduced to further extract and enrich aromatic amines by modified DLLME under vortexing. After centrifugation, toluene phase was purified by a universal QuEChERS cleanup kit and was finally analyzed by UPC2-MS/MS. Attributing to the superior performance of UPC2-MS/MS, this novel approach allowed the separation and determination of 9 aromatic amines within 5.0min with satisfactory resolution and sensitivity. The proposed method was finally validated using Kentucky reference cigarette 3R4F, and emission levels of targeted aromatic amines determined were comparable to previously reported methods At three different spiked levels, the recoveries of most analytes were ranged from 74.01% to 120.50% with relative standard deviation (RSD) less than 12%, except that the recovery of p-toluidine at low spiked level and 3-aminobiphenyl at medium spiked level was 62.77% and 69.37% respectively. Thus, this work provides a novel alternative method for the simultaneous analysis of 9 aromatic amines in mainstream cigarette smoke. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Salting-out assisted liquid-liquid extraction combined with gas chromatography-mass spectrometry for the determination of pyrethroid insecticides in high salinity and biological samples.

    Science.gov (United States)

    Niu, Zongliang; Yu, Chunwei; He, Xiaowen; Zhang, Jun; Wen, Yingying

    2017-09-05

    A salting-out assisted liquid-liquid extraction (SALLE) combined with gas chromatography-mass spectrometry (GC-MS) method was developed for the determination of four pyrethroid insecticides (PYRs) in high salinity and biological samples. Several parameters including sample pH, salting-out solution volume and salting-out solution pH influencing the extraction efficiency were systematically investigated with the aid of orthogonal design. The optimal extraction conditions of SALLE were: 4mL of salting-out solution with pH=4 and the sample pH=3. Under the optimum extraction and determination conditions, good responses for four PYRs were obtained in a range of 5-5000ng/mL, with linear coefficients greater than 0.998. The recoveries of the four PYRs ranged from 74% to 110%, with standard deviations ranging from 1.8% to 9.8%. The limits of detection based on a signal-to-noise ratio of 3 were between 1.5-60.6ng/mL. The method was applied to the determination of PYRs in urine, seawater and wastewater samples with a satisfactory result. The results demonstrated that this SALLE-GC-MS method was successfully applied to determine PYRs in high salinity and biological samples. SALLE avoided the need for the elimination of salinity and protein in the sample matrix, as well as clean-up of the extractant. Most of all, no centrifugation or any special apparatus are required, make this a promising method for rapid sample preparation procedure. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Extraction and Determination of Crocin in Saffron Samples by Dispersive Liquid-Liquid Microextraction

    Directory of Open Access Journals (Sweden)

    Somayeh Heydari

    2016-11-01

    Full Text Available The main component responsible for color in saffron is crocin with the chemical formula of C44H64O24. Crocin is one of several carotenoids in nature that is soluble in water. This solubility is one of the reasons for its widespread usage as a colorant in food and medicine compared to other carotenoids. The coloring strength of saffron is one of the major factors that determine the quality of the saffron stigma. It will be evaluated with measuring of crocin. Microextraction is the newest and easiest method that can be successfully applied for the preconcentration and separation of crocin in saffron samples. The advantages of this method are faster, cheaper and easier analysis by UV-Vis spectrophotometry in measurement of crocin compared to the chromatographic analysis methods. The studies showed that the type and volume of disperser and extractant solvent have a significant effect on the efficiency of crocin extraction. In this work, acetone as the disperser solvent and dichlorometane as the extractant solvent were found to be suitable combinations. Under the optimal conditions, the calibration curve was linear in the range of 0.15-0.00001 μg mL-1 and the limit of detection (LOD was calculated based on 3 Sb/m (where, Sb and m are the standard deviation of the blank and slop ratio of the calibration curve respectively was 0.000008 μg mL-1. The procedure was applied to saffron samples and the good recovery percent for the saffron samples was obtained.

  8. Neodymium(III) Complexes of Dialkylphosphoric and Dialkylphosphonic Acids Relevant to Liquid-Liquid Extraction Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lumetta, Gregg J.; Sinkov, Sergey I.; Krause, Jeanette A.; Sweet, Lucas E.

    2016-01-27

    The complexes formed during the extraction of neodymium(III) into hydrophobic solvents containing acidic organophosphorus extractants were probed by single-crystal X-ray diffractometry, visible spectrophotometry, and Fourier-transform infrared spectroscopy. The crystal structure of the compound Nd(DMP)3 (1, DMP = dimethyl phosphate) revealed a polymeric arrangement in which each Nd(III) center is surrounded by six DMP oxygen atoms in a pseudo-octahedral environment. Adjacent Nd(III) ions are bridged by (MeO)2POO– anions, forming the polymeric network. The diffuse reflectance visible spectrum of 1 is nearly identical to that of the solid that is formed when an n-dodecane solution of di-(2-ethylhexyl)phosphoric acid (HA) is saturated with Nd(III), indicating a similar coordination environment around the Nd center in the NdA3 solid. The visible spectrum of the HA solution fully loaded with Nd(III) is very similar to that of the NdA3 material, both displaying hypersensitive bands characteristic of an pseudo-octahedral coordination environment around Nd. These spectral characteristics persisted across a wide range of organic Nd concentrations, suggesting that the pseudo-octahedral coordination environment is maintained from dilute to saturated conditions.

  9. Separation of americium by liquid-liquid extraction using diglycol-amides water-soluble complexing agents

    Energy Technology Data Exchange (ETDEWEB)

    Chapron, S.; Marie, C.; Pacary, V.; Duchesne, M.T.; Miguirditchian, M. [CEA, Centre de Marcoule, Nuclear Energy Division, RadioChemistry and Processses Departement, 30207 Bagnols-sur-Ceze (France); Arrachart, G.; Pellet-Rostaing, S. [Institut de Chimie Separative de Marcoule, LTSM, Bat 426, F-30207 Bagnols-sur- Ceze (France)

    2016-07-01

    Recycling americium (Am) alone from spent nuclear fuels is an important option studied for the future nuclear cycle (Generation IV systems) since Am belongs to the main contributors of the long-term radiotoxicity and heat power of final waste. Since 2008, a liquid-liquid extraction process called EXAm has been developed by the CEA to allow the recovery of Am alone from a PUREX raffinate (a dissolution solution already cleared from U, Np and Pu). A mixture of DMDOHEMA (N,N'-dimethyl-N,N'-dioctyl-2-(2-(hexyloxy)ethyl)-malonamide) and HDEHP (di-2-ethylhexylphosphoric acid) in TPH is used as the solvent and the Am/Cm selectivity is improved using TEDGA (N,N,N',N'-tetraethyl-diglycolamide) as a selective complexing agent to maintain Cm and heavier lanthanides in the acidic aqueous phase (5 M HNO{sub 3}). Americium is then stripped selectively from light lanthanides at low acidity (pH=3) with a poly-aminocarboxylic acid. The feasibility of sole Am recovery was already demonstrated during hot tests in ATALANTE facility and the EXAm process was adapted to a concentrated raffinate to optimize the process compactness. The speciation of TEDGA complexes formed in the aqueous phase with Am, Cm and lanthanides was studied to better understand and model the behavior of TEDGA in the process. Some Ln-TEDGA species are extracted into the organic phase and this specific chemistry might play a role in the Am/Cm selectivity improvement. Hence the hydrophilicity-lipophilicity balance of the complexing agent is an important parameter. In this comprehensive study, new analogues of TEDGA were synthesized and tested in the EXAm process conditions to understand the relationship between their structure and selectivity. New derivatives of TEDGA with different N-alkyl chain lengths and ramifications were synthesized. The impact of lipophilicity on ligand partitioning and Am/Cm selectivity was investigated. (authors)

  10. Liquid-liquid extraction of biomolecules in downstream processing - A review paper

    Directory of Open Access Journals (Sweden)

    Silva M. E.

    2000-01-01

    Full Text Available Economic analysis shows that protein separation and purification are a very important aspect of biomolecules production and processing. This is particularly true for protein processing which, because of the complexity of the starting material, often requires many steps to reach the levels of purity required for medical and food applications. The separation specialists' task is to develop safe and simple processes to achieve products with a high level of purity. On a large scale, chromatography of proteins is not an easily applied method, although on a laboratory scale it is very effective and relatively simple. When it is scaled up, shortcomings such as discontinuity in the process, slow protein diffusion and large pressure drops in the system are seen. For these reasons a substantial research effort has been directed toward the use of aqueous two-phase systems (ATPSs to replace the initial steps in protein purification and chromatography. This article reviews the chronology and main ATPS fundamentals and discuss the broader applications of this type of system in the extraction and separation of biomolecules.

  11. Screening and quantitative determination of twelve acidic and neutral pharmaceuticals in whole blood by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Steentoft, Anni; Buck, Maike

    2010-01-01

    . The method was fully validated for salicylic acid, paracetamol, phenobarbital, carisoprodol, meprobamate, topiramate, etodolac, chlorzoxazone, furosemide, ibuprofen, warfarin, and salicylamide. The method also tentatively includes thiopental, theophylline, piroxicam, naproxen, diclophenac, and modafinil......We describe a multi-method for simultaneous identification and quantification of 12 acidic and neutral compounds in whole blood. The method involves a simple liquid-liquid extraction, and the identification and quantification are performed using liquid chromatography-tandem mass spectrometry...

  12. Comprehensive Profiling of Phytohormones in Honey by Sequential Liquid-Liquid Extraction Coupled with Liquid Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Wang, Qing; Cai, Wen-Jing; Yu, Lei; Ding, Jun; Feng, Yu-Qi

    2017-01-25

    Honey exhibits various nutritional and medicinal functions, which are highly related to the active components; thus, the exploration of new compounds in honey is of great importance. Because honey is a byproduct of flower nectar, which is rich in phytohormones, the existence of phytohormones in honey is anticipated. In this research, a method for comprehensive profiling of 49 phytohormones in honey was developed by sequential liquid-liquid extraction (LLE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Good linearities for 49 phytohormones were obtained with correlation coefficients (R) larger than 0.9913. The limits of detection (LODs) were in the range of 0.2-628.2 pg/mL. Satisfied reproducibility and reliability were achieved by evaluation of the intra- and interday precisions with relative standard deviations (RSDs) less than 15.8% and relative recoveries ranging from 80.4 to 123.7%. The method was further applied to analyze the phytohormones in 14 monofloral raw honey samples and 3 commercial honey samples. The existence of 34 phytohormones was confirmed, including 14 cytokinins (CKs), 8 gibberellins (GAs), 5 brassinosteroids (BRs), indole-3-acetic acid (IAA), indole-3-butyric acid (IBA), abscisic acid (ABA), salicylic acid (SA), jasmonic acid (JA), jasmonoyl-leucine (JA-Leu), and jasmonoyl-phenylalanine (JA-Phe). In addition, the content and species of phytohormones varies in different kinds of honey. The study is beneficial to fully illustrate the phytohormone profile of honey and contributive to elucidate the mechanism of its nutritional and medicinal functions.

  13. On-line automated sample preparation for liquid chromatography using parallel supported liquid membrane extraction and microporous membrane liquid-liquid extraction.

    Science.gov (United States)

    Sandahl, Margareta; Mathiasson, Lennart; Jönsson, Jan Ake

    2002-10-25

    An automated system was developed for analysis of non-polar and polar ionisable compounds at trace levels in natural water. Sample work-up was performed in a flow system using two parallel membrane extraction units. This system was connected on-line to a reversed-phase HPLC system for final determination. One of the membrane units was used for supported liquid membrane (SLM) extraction, which is suitable for ionisable or permanently charged compounds. The other unit was used for microporous membrane liquid-liquid extraction (MMLLE) suitable for uncharged compounds. The fungicide thiophanate methyl and its polar metabolites carbendazim and 2-aminobenzimidazole were used as model compounds. The whole system was controlled by means of four syringe pumps. While extracting one part of the sample using the SLM technique. the extract from the MMLLE extraction was analysed and vice versa. This gave a total analysis time of 63 min for each sample resulting in a sample throughput of 22 samples per 24 h.

  14. High-Throughput Determination of Sodium Danshensu in Beagle Dogs by the LCMS/MS Method, Employing Liquid-Liquid Extraction Based on 96-Well Format Plates

    Directory of Open Access Journals (Sweden)

    Jingjing Jiang

    2017-04-01

    Full Text Available Sodium Danshensu (sodium d-(+-β-(3,4-dihydroxyphenyl lactate, one of the water-soluble ingredients in Salvia miltiorrhiza, exhibits potent relaxation of the coronary artery and anticoagulation effection. A high-throughput, rapid, and sensitive method combining liquid chromatography with electrospray ionization tandem mass spectrometry to determine the sodium danshensu in beagle dog plasma was developed and validated, using gallic acid as an internal standard (IS. Acidified plasma samples were extracted using 96-well liquid-liquid extraction, and were eluted on a CNW Athena C18 column (3 μm, 2.1 × 100 mm by using a gradient mobile phase system of methanol and water (containing 0.2% formic acid. The mass spectrometric detection was achieved using negative ion electrospray ionization mode and monitoring the precursor→production combinations of m/z 197→135 for sodium danshensu and 169→125 for IS, in multiple reaction monitoring modes. Good linearity was achieved, and the linear range was 10–1000 ng/mL (R2 > 0.996 with a quantification limit of 10 ng/mL for sodium danshensu in beagle dog plasma. The intra- and inter-day precision (RSD ranged from 2.1% to 9.0%. The accuracy (RE was between −8.6% and 5.7% at all quality control levels. The validated method was successfully applied to the pharmacokinetics study of sodium danshensu in beagle dog plasma after intravenous injection and oral administration of sodium danshensu.

  15. Selective Liquid-Liquid Extraction of Lead Ions Using Newly Synthesized Extractant 2-(Dibutylcarbamoyl)benzoic Acid

    OpenAIRE

    Hossein Soltani; Mohammad Reza Yaftian; Abbasali Zamani; Massomeh Ghorbanloo

    2015-01-01

    A new carboxylic acid extractant, named 2-(dibutylcarbamoyl)benzoic acid, is prepared and its potential for selective solvent extraction and recovery of lead ions from industrial samples was investigated. The slope analysis indicated that the lead ions are extracted by formation of 1:2 metal to ligand complexes. The effect of the parameters influencing the extraction efficiency including kind of the organic diluent, extractant concentration, type of the salt used for ionic strength adjustment...

  16. MicroSISAK. Continuous liquid-liquid extractions of radionuclides at {>=} 0.2 mL/min

    Energy Technology Data Exchange (ETDEWEB)

    Hild, D.; Eberhardt, K.; Kratz, J.V.; Wiehl, N. [Mainz Univ. (Germany). Inst. fuer Kernchemie; Even, J. [Mainz Univ. (Germany). Inst. fuer Kernchemie; Helmholtz-Institut Mainz, Mainz (Germany); Loeb, P.; Werner, B.; Hofmann, C. [Institut fuer Mikrotechnik Mainz GmbH, Mainz (Germany)

    2013-07-01

    Continuous liquid-liquid extraction of short-lived radionuclides has traditionally been performed with the SISAK system consisting of static mixers and H-centrifuges for phase separation. SISAK operates at flow rates of typically 1 mL/s. Thus, it produces large volumes of radioactive liquid waste that is difficult to dispose of. Therefore, it has been aimed to develop and use a further miniaturised extraction unit based on microtechnology and precision engineering to reduce the flow rate by at least two orders of magnitude. The accordingly developed MicroSISAK device is a micro membrane extractor in which a micromixer element with 2 x 16 feed channels of 30 {mu}m width followed by a 60 {mu}m high mixing chamber is used for intimately contacting the aqueous and organic phase. Subsequent phase separation is achieved via hydrophobic Teflon membranes with a pore size of 1 {mu}m. The MicroSISAK device has been tested and optimized with radiotracers of the group-4 elements Zr and Hf in the system H{sub 2}SO{sub 4}/trioctyl amine (TOA) in toluene. At a temperature of 58 C and a flow rate of 0.2 mL/min of both phases, extraction yields of 87 {+-} 3% were achieved. The transport time from the micromixer to the first Teflon membrane was in this case 3.9s. It can be shortened to 1.56s at a flow rate of 0.5 mL/min. Under similar conditions, the extraction yield of {sup 99m}Tc milked from a {sup 99}Mo generator in the system HNO{sub 3}/tetraphenyl arsonium chloride (TPAC) in chloroform was 83 {+-} 3%. In an on-line experiment at the TRIGA Mainz reactor, short-lived Tc isotopes produced in the fission of {sup 235}U with thermal neutrons were transported by a He/KCl gas-jet to the chemistry apparatus, deposited by impaction, dissolved in 0.01 mol/L HNO{sub 3}/KBrO{sub 3}, and extracted into 10{sup -4} mol/L TPAC in chloroform in MicroSISAK. The separated phases were transported via capillaries to two separate flow-through cells positioned in front of two Ge detectors. The

  17. Determination of chlorobenzenes in textiles by pressurized hot water extraction followed by vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lu, Yang; Zhu, Yan

    2013-12-06

    A method for quantitative determination of chlorobenzenes in textiles is developed, using pressurized hot water extraction (PHWE), vortex-assisted liquid-liquid microextraction (VALLME) and gas chromatography-mass spectrometry (GC-MS). VALLME serves as a trapping step after PHWE. The extraction conditions are investigated, as well as the quantitative features such as linearity, limits of detection (LODs), limits of quantification (LOQs), repeatabilities and reproducibilities between days. LOQs of 0.018-0.032mg/kg were achieved. The present method provides good repeatabilities (RSDtextiles. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. "Bligh and Dyer" and Folch Methods for Solid-Liquid-Liquid Extraction of Lipids from Microorganisms. Comprehension of Solvatation Mechanisms and towards Substitution with Alternative Solvents.

    Science.gov (United States)

    Breil, Cassandra; Abert Vian, Maryline; Zemb, Thomas; Kunz, Werner; Chemat, Farid

    2017-03-27

    Bligh and Dyer (B & D) or Folch procedures for the extraction and separation of lipids from microorganisms and biological tissues using chloroform/methanol/water have been used tens of thousands of times and are "gold standards" for the analysis of extracted lipids. Based on the Conductor-like Screening MOdel for realistic Solvatation (COSMO-RS), we select ethanol and ethyl acetate as being potentially suitable for the substitution of methanol and chloroform. We confirm this by performing solid-liquid extraction of yeast ( Yarrowia lipolytica IFP29 ) and subsequent liquid-liquid partition-the two steps of routine extraction. For this purpose, we consider similar points in the ternary phase diagrams of water/methanol/chloroform and water/ethanol/ethyl acetate, both in the monophasic mixtures and in the liquid-liquid miscibility gap. Based on high performance thin-layer chromatography (HPTLC) to obtain the distribution of lipids classes, and gas chromatography coupled with a flame ionisation detector (GC/FID) to obtain fatty acid profiles, this greener solvents pair is found to be almost as effective as the classic methanol-chloroform couple in terms of efficiency and selectivity of lipids and non-lipid material. Moreover, using these bio-sourced solvents as an alternative system is shown to be as effective as the classical system in terms of the yield of lipids extracted from microorganism tissues, independently of their apparent hydrophilicity.

  19. Speciation of organotin compounds in urine by GC-MIP-AED and GC-MS after ethylation and liquid-liquid extraction.

    Science.gov (United States)

    Zachariadis, G A; Rosenberg, E

    2009-04-15

    A method for the determination of organotin compounds in urine samples based on liquid-liquid extraction (LLE) in hexane and gas chromatographic separation was developed and optimized. Seven organotin species, namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), tetrabutyltin (TeBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT), were in situ derivatized by sodium tetraethylborate (NaBEt(4)) to form ethylated less polar derivatives directly in the urine matrix. The critical parameters which have a significant effect on the yield of the successive liquid-liquid extraction procedure were examined, by using standard solutions of tetrabutyltin in hexane. The method was optimized for use in direct analysis of undiluted human urine samples and ways to overcome practical problems such as foam formation during extraction, due to various constituents of urine are discussed. After thorough optimization of the extraction procedure, all examined species could be determined after 3 min of simultaneous derivatization and extraction at room temperature and 5 min phase separation by centrifugation. Gas chromatography with a microwave-induced plasma atomic emission detector (MIP-AED) as element specific detector was employed for quantitative measurements, while a quadrupole mass spectrometric detector (MS) was used as molecular specific detector. The detection limits were between 0.42 and 0.67 microg L(-1) (as Sn) for the quantitative LLE-GC-MIP-AED method and the precision between 4.2% and 11.7%, respectively.

  20. Optimization of an accelerated solvent extraction dispersive liquid-liquid microextraction method for the separation and determination of essential oil from Ligusticum chuanxiong Hort by gas chromatography with mass spectrometry.

    Science.gov (United States)

    Yang, Guang; Sun, Qiushi; Hu, Zhiyan; Liu, Hua; Zhou, Tingting; Fan, Guorong

    2015-10-01

    In this study, an accelerated solvent extraction dispersive liquid-liquid microextraction coupled with gas chromatography and mass spectrometry was established and employed for the extraction, concentration and analysis of essential oil constituents from Ligusticum chuanxiong Hort. Response surface methodology was performed to optimize the key parameters in accelerated solvent extraction on the extraction efficiency, and key parameters in dispersive liquid-liquid microextraction were discussed as well. Two representative constituents in Ligusticum chuanxiong Hort, (Z)-ligustilide and n-butylphthalide, were quantitatively analyzed. It was shown that the qualitative result of the accelerated solvent extraction dispersive liquid-liquid microextraction approach was in good agreement with that of hydro-distillation, whereas the proposed approach took far less extraction time (30 min), consumed less plant material (usually extraction and analysis of essential oil. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Low-temperature liquid-liquid extraction of phenols from aqueous solutions with hydrophilic mixtures of extractants

    Science.gov (United States)

    Rudakov, O. B.; Khorokhordina, E. A.; Preobrazhenskii, M. A.; Rudakova, L. V.

    2016-08-01

    The volume ratios in acetonitrile-ethyl acetate (90 : 10, 95 : 5), acetonitrile-isopropanol-ethyl acetate (70 : 15 : 15, 80 : 5 : 15), and isopropanol-1-butanol (50 : 50) mixtures were determined. Their mixing with water (1 : 1) and storage at-10°C led to partitioning into two immiscible liquid phases without formation of the ice phase. The mixtures were shown to be useful as hydrophilic extractants in low-temperature liquidliquid extraction of phenol from aqueous solutions.

  2. Rapid removal of nitrobenzene in a three-phase ozone loaded system with gas-liquid-liquid

    Science.gov (United States)

    Li, Shiyin; Zhu, Jiangpeng; Wang, Guoxiang; Ni, Lixiao; Zhang, Yong; Green, Christopher T.

    2015-01-01

    This study explores the removal rate of nitrobenzene (NB) using a new gas-liquid-liquid (G-L-L) three-phase ozone loaded system consisting of a gaseous ozone, an aqueous solvent phase, and a fluorinated solvent phase (perfluorodecalin, or FDC). The removal rate of NB was quantified in relation to six factors including 1) initial pH, 2) initial NB dosage, 3) gaseous ozone dosage, 4) free radical scavenger, 5) FDC pre-aerated gaseous ozone, and 6) reuse of FDC. The NB removal rate is positively affected by the first three factors. Compared with the conventional gas-liquid (water) (G-L) two-phase ozonation system, the free radical scavenger (tertiary butyl alcohol) has much less influence on the removal rate of NB in the G-L-L system. The FDC loaded ozone acts as an ozone reservoir and serves as the main reactive phase in the G-L-L three-phase system. The reuse of FDC has little influence on the removal rate of NB. These experimental results suggest that the oxidation efficiency of ozonation in the G-L-L three-phase system is better than that in the conventional G-L two-phase system.

  3. Highly Efficient and Robust Enantioselective Liquid-Liquid Extraction of 1,2-Amino Alcohols utilizing VAPOL- and VANOL-based Phosphoric Acid Hosts.

    Science.gov (United States)

    Pinxterhuis, Erik B; Gualtierotti, Jean-Baptiste; Wezenberg, Sander J; de Vries, Johannes G; Feringa, Ben L

    2018-01-10

    The large-scale production of enantiopure compounds in a cost-effective and environmentally friendly manner remains one of the major challenges of modern-day chemistry. The resolution of racemates through enantioselective liquid-liquid extraction was developed as a suitable solution but has remained largely underused, owing to a lack of highly efficient and robust chiral hosts to mediate the process. This paucity of hosts can in part be attributed to a poor understanding of the underlying principles behind these processes hindering the design of more efficient selectors. A previously untested class of hosts, VAPOL and VANOL derived phosphoric acids, has been studied in depth for the efficient enantioselective liquid-liquid extraction of 1,2-amino alcohols. A systematic investigation of extraction parameters was conducted, revealing many key interactions and DFT calculations illustrate the binding modes for the 1:1 complexes that are involved in chiral recognition. The resulting, now-optimized, procedures are highly robust and easy to implement. They are also easily scalable, as demonstrated by U-tube experiments. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Comparison of the solid phase and liquid-liquid extraction methods for methadone determination in human serum and whole blood samples using gas chromatography/mass spectrometry.

    Science.gov (United States)

    Bratinčević, Maja Veršić; Visković, Tanja; Sutlović, Davorka

    2017-12-20

    The aim of this study was to determine the optimal biological sample and the optimal extraction technique for monitoring methadone concentrations in biological samples. We analysed methadone in serum and whole blood samples using gas chromatography/mass spectrometry (GC/MS). Before analysis, we compared five solid-phase extraction (SPE) and two liquid-liquid extraction (LLE) methods and determined that SPE with Supelco LC-18 in serum yielded the best extraction efficiency. The limit of detection was 10 ng mL-1 and the limit of quantification 25 ng mL-1. Correlation coefficient was over 0.999 for the methadone calibration curve in linear range from 50 to 2000 ng mL-1. Intra and inter-day accuracy and precision of the method was satisfactory. The method was successfully applied for determining serum methadone in patients on maintenance therapy.

  5. RAPID AND SENSITIVE DETERMINATION OF PALLADIUM USING HOMOGENEOUS LIQUID-LIQUID MICROEXTRACTION VIA FLOTATION ASSISTANCE FOLLOWED BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Mohammad Rezaee

    2015-05-01

    Full Text Available A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA followed by graphite furnace atomic absorption spectrometry (GFAAS. Ammonium pyrrolidine dithiocarbamate (APDC was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.

  6. Extraction of toluene from aliphatic compounds using an ionic liquid as solvent: Influence of the alkane on the (liquid + liquid) equilibrium

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Emilio J. [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain); Calvar, Noelia, E-mail: noecs@uvigo.e [Laboratory of Separation and Reaction Engineering, Departamento de Engenharia Quimica, Facultade de Engenharia, Universidade de Porto, Rua Dr. Roberto Frias, 4200-465 Porto (Portugal); Dominguez, Irene; Dominguez, Angeles [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain)

    2011-04-15

    Research highlights: An ionic liquid was analyzed as solvent for extraction of toluene from alkanes. Liquid-liquid equilibrium data were measured at 298.15 K and atmospheric pressure. Selectivity and solute distribution ratio were obtained and compared with literature. The Othmer-Tobias equation was used to ascertain the experimental LLE data. Experimental data were correlated using NRTL and UNIQUAC models. - Abstract: In this paper, the feasibility of using 1-ethyl-3-methylimidazolium ethylsulfate ionic liquid, [EMim][ESO{sub 4}], as solvent for the extraction of toluene from aliphatic compounds (hexane, heptane, octane, or nonane) was analyzed. (Liquid + liquid) equilibrium (LLE) data for the ternary systems {l_brace}alkane (1) + toluene (2) + [EMim][ESO{sub 4}] (3){r_brace} were measured at T = 298.15 K and atmospheric pressure. Selectivity and solute distribution ratio were calculated from the experimental LLE data, and the obtained values were compared to those previously reported using other ionic liquids and sulfolane. The degree of consistency of the experimental LLE data was ascertained using the Othmer-Tobias equation. Finally, the experimental LLE data were satisfactorily correlated with NRTL and UNIQUAC models.

  7. Separation of {sup 195(m,g),197m}Hg from bulk gold target by liquid-liquid extraction using hydrophobic ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Kaustab; Lahiri, Susanta [Saha Institute of Nuclear Physics, Kolkata (India). Chemical Sciences Div.; Maiti, Moumita [Indian Institute of Technology Roorkee, Roorkee (India). Dept. of Physics

    2017-07-01

    The {sup 195(m,g),197m}Hg radionuclides were produced in accelerator when natural Au foil was irradiated with 23 MeV protons. The no-carrier-added (NCA) Hg radioisotopes were separated from the bulk Au target by liquid-liquid extraction (LLX) employing hydrophobic RTILs 1-butyl-3-methylimidazolium hexafluorophosphate([C{sub 4}mim][PF{sub 6}]) and 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide([bmim][Tf{sub 2}N]) as extractant with HNO{sub 3} and HCl. In each case, bulk Au was extracted into the RTIL phase leaving NCA Hg-radionuclides in the aqueous phase. The RTILs were recovered by washing with 1 M K{sub 2}S{sub 2}O{sub 5} and freshly prepared 1 M FeSO{sub 4}. The reported separation methods follow green chemistry approach as it does not involve any volatile reagents.

  8. Air-assisted liquid-liquid microextraction using floating organic droplet solidification for simultaneous extraction and spectrophotometric determination of some drugs in biological samples through chemometrics methods

    Science.gov (United States)

    Farahmand, Farnaz; Ghasemzadeh, Bahar; Naseri, Abdolhossein

    2018-01-01

    An air assisted liquid-liquid microextraction by applying the solidification of a floating organic droplet method (AALLME-SFOD) coupled with a multivariate calibration method, namely partial least squares (PLS), was introduced for the fast and easy determination of Atenolol (ATE), Propanolol (PRO) and Carvedilol (CAR) in biological samples via a spectrophotometric approach. The analytes would be extracted from neutral aqueous solution into 1-dodecanol as an organic solvent, using AALLME. In this approach a low-density solvent with a melting point close to room temperature was applied as the extraction solvent. The emulsion was immediately formed by repeatedly pulling in and pushing out the aqueous sample solution and extraction solvent mixture via a 10-mL glass syringe for ten times. After centrifugation, the extractant droplet could be simply collected from the aqueous samples by solidifying the emulsion at a lower than the melting point temperature. In the next step, analytes were back extracted simultaneously into the acidic aqueous solution. Derringer and Suich multi-response optimization were utilized for simultaneous optimizing the parameters of three analytes. This method incorporates the benefits of AALLME and dispersive liquid-liquid microextraction considering the solidification of floating organic droplets (DLLME-SFOD). Calibration graphs under optimized conditions were linear in the range of 0.30-6.00, 0.32-2.00 and 0.30-1.40 μg mL- 1 for ATE, CAR and PRO, respectively. Other analytical parameters were obtained as follows: enrichment factors (EFs) were found to be 11.24, 16.55 and 14.90, and limits of detection (LODs) were determined to be 0.09, 0.10 and 0.08 μg mL- 1 for ATE, CAR and PRO, respectively. The proposed method will require neither a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly.

  9. Comparison of ultrasound-assisted cloud point extraction and ultrasound-assisted dispersive liquid liquid microextraction for copper coupled with spectrophotometric determination

    Science.gov (United States)

    Yang, Shengchun; Fang, Xiang; Duan, Liju; Yang, Shu; Lei, Zirong; Wen, Xiaodong

    2015-09-01

    In this work, ultrasound-assisted cloud point extraction (UA-CPE) and ultrasound-assisted dispersive liquid liquid microextraction (UA-DLLME) were investigated and compared firstly as ultrasound-assisted liquid phase microextraction methods, which were coupled with spectrophotometer for copper preconcentration and detection. Compared to conventional CPE and DLLME, the extraction patterns were changed and improved by the effect of ultrasound. As novel methods, their applications were expanded and the analytical performance of spectrophotometric determination for copper was considerably improved. The influence factors of UA-CPE and UA-DLLME were studied in detail. Under the optimal conditions, the limits of detection (LODs) for copper were 0.7 μg L-1 of UA-CPE and 0.8 μg L-1 of UA-DLLME with sensitivity enhancement factors (EFs) of 17 and 16. The developed methods were applied to the determination of trace copper in real water samples with satisfactory analytical results.

  10. Liquid-liquid extraction kinetics of uranyl nitrate and actinides (III)-lanthanides nitrates by extractants with amide function; Cinetique d`extraction liquide-liquide du nitrate d`uranyle et des nitrates d`actinides (III) et de lanthanides (III) par des extractants a fonction amide

    Energy Technology Data Exchange (ETDEWEB)

    Toulemonde, V.

    1995-12-20

    Nowadays, the most important part of electric power is generated by fission energy. But spent fuels have then to be reprocessed. The production of these reprocessed materials separately and with a high purity level is done according to a liquid-liquid extraction process (Purex process) with the use of tributyl phosphate as solvent. Optimization studies concerning the extracting agent have been undertaken. This work gives the results obtained for the uranyl nitrate and the actinides (III)-lanthanides (III) nitrates extraction by extractants with amide function (monoamide for U(VI) and diamide for actinides (III) and lanthanides (III)). The extraction kinetics have been studied in the case of a metallic specie transfer from the aqueous phase towards the organic phase. The experiments show that the nitrates extraction kinetics is limited by the complexation chemical reaction of the species at the interface between the two liquids. An adsorption-desorption interfacial reactional mechanism (Langmuir theory) is proposed for the uranyl nitrate. (O.M.). 89 refs.

  11. A rapid ultrasound-assisted dispersive liquid-liquid microextraction followed by ultra-performance liquid chromatography for the simultaneous determination of seven benzodiazepines in human plasma samples.

    Science.gov (United States)

    Fernández, Purificación; González, Cristina; Pena, M Teresa; Carro, Antonia M; Lorenzo, Rosa A

    2013-03-12

    A simple and efficient ultrasound-assisted dispersive liquid-liquid microextraction (UA-DLLME) method has been developed for the determination of seven benzodiazepines (alprazolam, bromazepam, clonazepam, diazepam, lorazepam, lormetazepam and tetrazepam) in human plasma samples. Chloroform and methanol were used as extractant and disperser solvents, respectively. The influence of several variables (e.g., type and volume of dispersant and extraction solvents, pH, ultrasonic time and ionic strength) was carefully evaluated and optimized, using an asymmetric screening design 3(2)4(2)//16. Analysis of extracts was performed by ultra-performance liquid chromatography coupled with photodiode array detection (UPLC-PDA). Under the optimum conditions, two reversed-phases, Shield RP18 and C18 columns were successfully tested, obtaining good linearity in a range of 0.01-5μgmL(-1), with correlation coefficients r>0.996. Quantification limits ranged between 4.3-13.2ngmL(-1) and 4.0-14.8ngmL(-1), were obtained for C18 and Shield RP18 columns, respectively. The optimized method exhibited a good precision level, with relative standard deviation values lower than 8%. The recoveries studied at two spiked levels, ranged from 71 to 102% for all considered compounds. The proposed method was successfully applied to the analysis of seven benzodiazepines in real human plasma samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. CHEMOMETRICS IN BIOANALYTICAL SAMPLE PREPARATION - A FRACTIONATED COMBINED MIXTURE AND FACTORIAL DESIGN FOR THE MODELING OF THE RECOVERY OF 5 TRICYCLIC AMINES FROM PLASMA AFTER LIQUID-LIQUID-EXTRACTION PRIOR TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

    NARCIS (Netherlands)

    WIELING, J; MENSINK, CK; JONKMAN, JHG; COENEGRACHT, PMJ; DUINEVELD, CAA; DOORNBOS, DA

    1993-01-01

    A general systematic approach is described for the chemometric modelling of liquid-liquid extraction data of drugs from biological fluids. Extraction solvents were selected from Snyder's solvent selectivity triangle: methyl tert.-butyl ether, methylene chloride and chloroform. The composition of a

  13. Monitoring the oleuropein content of olive leaves and fruits using ultrasound- and salt-assisted liquid-liquid extraction optimized by response surface methodology and high-performance liquid chromatography.

    Science.gov (United States)

    Ismaili, Ahmad; Heydari, Rouhollah; Rezaeepour, Reza

    2016-01-01

    A novel and rapid ultrasound- and salt-assisted liquid-liquid extraction coupled with high-performance liquid chromatography has been optimized by response surface methodology for the determination of oleuropein from olive leaves. Box-Behnken design was used for optimizing the main parameters including ultrasound time (A), pH (B), salt concentration (C), and volume of miscible organic solvent (D). In this technique, a mixture of plant sample and extraction solvent was subjected to ultrasound waves. After ultrasound-assisted extraction, phase separation was performed by the addition of salt to the liquid phase. The optimal conditions for the highest extraction yield of oleuropein were ultrasound time, 30 min; volume of organic solvent, 2.5 mL; salt concentration, 25% w/v; and sample pH, 4. Experimental data were fitted with a quadratic model. Analysis of variance results show that BC interaction, A(2) , B(2) , C(2) , and D(2) are significant model terms. Unlike the conventional extraction methods for plant extracts, no evaporation and reconstitution operations were needed in the proposed technique. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Ionic-liquid-based dispersive liquid-liquid microextraction combined with magnetic solid-phase extraction for the determination of aflatoxins B1 , B2 , G1 , and G2 in animal feeds by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Zhao, Jiao; Zhu, Yan; Jiao, Yang; Ning, Jinyan; Yang, Yaling

    2016-10-01

    A novel two-step extraction technique combining ionic-liquid-based dispersive liquid-liquid microextraction with magnetic solid-phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high-performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1-octyl-3-methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid-liquid microextraction, and hydrophobic pelargonic acid modified Fe3 O4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins-containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid-liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid-liquid microextraction and magnetic solid-phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3-103.7% with relative standard deviations of 3.2-6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B1 , B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Coupling of solvent-based de-emulsification dispersive liquid-liquid microextraction with high performance liquid chromatography for simultaneous simple and rapid trace monitoring of 2,4-dichlorophenoxyacetic acid and 2-methyl-4-chlorophenoxyacetic acid.

    Science.gov (United States)

    Behbahani, Mohammad; Najafi, Fatemeh; Bagheri, Saman; Bojdi, Majid Kalate; Hassanlou, Parmoon Ghareh; Bagheri, Akbar

    2014-04-01

    A simple, rapid, and efficient sample pretreatment technique, based on solvent-based de-emulsification dispersive liquid-liquid microextraction (SD-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for simultaneous preconcentration and trace detection of 2,4-dichlorophenoxyacetic acid (2,4-D) and 2-methyl-4-chlorophenoxyacetic acid (MCPA) in water and urine samples. Some parameters such as acidity of solution, the amount of salt, type, and volume of extraction solvents, type of disperser/de-emulsifier solvent, and its volume were investigated and optimized. Under optimum extraction conditions, the limits of detections (LODs) of this method for MCPA and 2,4-D were 0.2 and 0.6 μg L(-1) (based on 3S(b)/m) in water and 0.4 and 1.6 μg L(-1) in urine, respectively. Furthermore, dynamic linear range of this method for MCPA and 2,4-D was 1-300 and 2-400 μg L(-1), repectively. Finally, the applicability of the proposed method was evaluated by extraction and determination of the herbicides in urine and different water samples.

  16. Analysis of ecstasy in oral fluid by ion mobility spectrometry and infrared spectroscopy after liquid-liquid extraction.

    Science.gov (United States)

    Armenta, Sergio; Garrigues, Salvador; de la Guardia, Miguel; Brassier, Judit; Alcalà, Manel; Blanco, Marcelo

    2015-03-06

    We developed and evaluated two different strategies for determining abuse drugs based on (i) the analysis of saliva by ion mobility spectrometry (IMS) after thermal desorption and (ii) the joint use of IMS and infrared (IR) spectroscopy after liquid-liquid microextraction (LLME) to enable the sensitivity-enhanced detection and double confirmation of ecstasy (MDMA) abuse. Both strategies proved effective for the intended purpose. Analysing saliva by IMS after thermal desorption, which provides a limit of detection (LOD) of 160μgL(-1), requires adding 0.2M acetic acid to the sample and using the truncated negative second derivative of the ion mobility spectrum. The joint use of IMS and IR spectroscopy after LLME provides an LOD of 11μgL(-1) with the former technique and 800μgL(-1) with the latter, in addition to a limit of confirmation (LOC) of 1.5mgL(-1). Using IMS after thermal desorption simplifies the operational procedure, and using it jointly with IR spectroscopy after LLME allows double confirmation of MDMA abuse with two techniques based on different principles (viz., IMS drift times and IR spectra). Also, it affords on-site analyses, albeit at a lower throughput. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Liquid-liquid extraction of ethanol from aqueous solutions with amyl acetate, benzyl alcohol, and methyl isobutyl ketone at 298. 15. Kappa

    Energy Technology Data Exchange (ETDEWEB)

    Solimo, H.N. (Instituto de Fisica, Facultad de Ciencias Exactas y Tecnologia, Universidad Nacional de Tucuman, 4000 San Miguel de Tucuman (AR)); Martinez, H.E.; Riggio, R. (Facultad de Ciencias Naturales, Universidad Nacional de Salta, 4400 Salta (AR))

    1989-04-01

    Experimental mutual solubility and tie-line data were determined for three ternary liquid-liquid systems containing water, ethanol, and amyl acetate, benzyl alcohol, and methyl isobutyl ketone at 298.15{Kappa} in order to obtain their complete phase diagrams and to determine which is the most suitable solvent for extraction of ethanol from aqueous solutions. Tie lines were determined correlating the density of the binodal curve as a function of composition and the plait points using the Othmer and Tobias method. The experimental data were also correlated with the UNIFAC group contribution method. A qualitative agreement was obtained. Experimental results show that amyl acetate is a better solvent than methyl isobutyl ketone and benzyl alcohol.

  18. Analysis of potential migrants from plastic materials in milk by liquid chromatography-mass spectrometry with liquid-liquid extraction and low-temperature purification.

    Science.gov (United States)

    Bodai, Zsolt; Szabó, Bálint Sámuel; Novák, Márton; Hámori, Susanne; Nyiri, Zoltán; Rikker, Tamás; Eke, Zsuzsanna

    2014-10-15

    A simple and fast analytical method was developed for the determination of six UV stabilizers (Cyasorb UV-1164, Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, and Tinuvin 1577) and five antioxidants (Irgafos 168, Irganox 1010, Irganox 3114, Irganox 3790, and Irganox 565) in milk. For sample preparation liquid-liquid extraction with low-temperature purification combined with centrifugation was used to remove fats, proteins, and sugars. After the cleanup step, the sample was analyzed with high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). External standard and matrix calibrations were tested. External calibration proved to be acceptable for Tinuvin P, Tinuvin 234, Tinuvin 326, Tinuvin 327, Irganox 3114, and Irganox 3790. The method was successfully validated with matrix calibration for all compounds. Method detection limits were between 0.25 and 10 μg/kg. Accuracies ranged from 93 to 109%, and intraday precisions were <13%.

  19. Cation-exchange solid-phase and liquid-liquid extraction for the determination of khat alkaloids by reversed phase HPLC-DAD

    Directory of Open Access Journals (Sweden)

    M. Atlabachew

    2015-10-01

    Full Text Available Leaves of khat (Catha edulis are masticated to elicit their psycho-stimulating properties, resulting from the presence of the phenylpropylamino alkaloids. The determination of these alkaloids is important in pharmacological, phytochemical, forensic and law enforcement environments. In this study, the use of strong cation exchange-solid phase extraction (SCX-SPE was investigated as an alternative means of sample purification prior to the determination of cathinone, cathine and norephedrine by reversed phase (C18 high performance liquid chromatography (HPLC. Extraction parameters for SCX, including loading capacity and washing solvents, were established. An existing liquid-liquid extraction (LLE method was improved in terms of recoveries obtained, by using ethyl acetate as extractant. For pure standards of the khat alkaloids, recoveries ranged from 83 to 97%. Preconcentration, using a Genevac evaporator after the addition of acidified water to the sample, restricted analyte losses when compared to concentration under nitrogen. Although comparable recoveries were obtained when preconcentration was achieved in the presence of acidified water by rotary evaporation, this method is not suitable for large sample numbers. Best recoveries, ranging from 94 to 102%, were obtained by SCX from spiked samples. Although the extraction efficiencies of LLE were lower (87-90%, LLE yielded less complex chromatograms, indicating a purer extract.DOI: http://dx.doi.org/10.4314/bcse.v29i3.1

  20. Determination of 2-ethylhexyl 4-(dimethylamino) benzoate using membrane-assisted liquid-liquid extraction and gas chromatography-mass spectrometric detection.

    Science.gov (United States)

    March, J G; Genestar, C; Simonet, B M

    2009-06-01

    A flow-cell for micro-porous membrane liquid-liquid extraction with a sheet membrane was used to extract 2-ethylhexyl 4-(dimethylamino) benzoate (EDB) from urine of solar-cream users and spiked wine samples. The cell enabled the target analyte to be extracted from 7.9 mL of donor solution into 200 microL of acceptor solution (decane). After extraction, the acceptor solution was transferred to a micro-vial for GC-MS analysis without derivation. In this work, variables affecting the enrichment factor were also studied, such as organic solvent, extraction time, recirculation flow of the donor solution through the donor chamber, presence of potassium chloride and ethanol in the donor solution and pH. The method has been evaluated in terms of linearity, sensitivity, precision, limits of detection and quantification and extraction efficiency. Limits of quantification were 1 and 3 microg L(-1) EDB for urine and wine, respectively. Quantitative analysis has been carried out by applying the method of standard additions. Within- and between-day relative standard deviations were lower than 12% and 20%, respectively. EDB was found in the urine of users of cream containing EDB in the concentration interval 1.2-7.2 microg L(-1). Therefore, this provides evidence of EDB dermal absorption and subsequent excretion through the urinary tract. EDB was not found in the analysed wine samples.

  1. Maghemite nanoparticle-decorated hollow fiber electromembrane extraction combined with dispersive liquid-liquid microextraction for determination of thymol from Carum copticum.

    Science.gov (United States)

    Khajeh, Mostafa; Pedersen-Bjergaard, Stig; Bohlooli, Mousa; Barkhordar, Afsaneh; Ghaffari-Moghaddam, Mansour

    2017-03-01

    A novel technique using maghemite nanoparticle-decorated hollow fibers to assist electromembrane extraction is proposed. Electromembrane extraction combined with dispersive liquid-liquid microextraction (EME-DLLME) was applied for the extraction of thymol from Carum copticum, followed by gas chromatography with flame ionization detection (GC-FID). The use of maghemite nanoparticle-decorated hollow fibers was found to improve the extraction efficiency of thymol significantly. Important operational parameters, including pH of acceptor phase, extraction time, voltage and temperature, were investigated and optimized. At the optimal conditions, linearity in the range 4-1800 µg L-1 with a determination coefficient of 0.9996 was obtained. The limit of detection was 0.11 µg L-1 (S/N = 3) and the pre-concentration factor was 200. The intra- and inter-day precision was 5.9 and 2.2% respectively. The intra- and inter-day accuracy was higher than 93.6%. The results indicated that EME-DLLME/GC-FID is a useful technique for the extraction and determination of thymol in C copticum. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  2. Comparison of salting-out and sugaring-out liquid-liquid extraction methods for the partition of 10-hydroxy-2-decenoic acid in royal jelly and their co-extracted protein content.

    Science.gov (United States)

    Tu, Xijuan; Sun, Fanyi; Wu, Siyuan; Liu, Weiyi; Gao, Zhaosheng; Huang, Shaokang; Chen, Wenbin

    2018-01-15

    Homogeneous liquid-liquid extraction (h-LLE) has been receiving considerable attention as a sample preparation method due to its simple and fast partition of compounds with a wide range of polarities. To better understand the differences between the two h-LLE extraction approaches, salting-out assisted liquid-liquid extraction (SALLE) and sugaring-out assisted liquid-liquid extraction (SULLE), have been compared for the partition of 10-hydroxy-2-decenoic acid (10-HDA) from royal jelly, and for the co-extraction of proteins. Effects of the amount of phase partition agents and the concentration of acetonitrile (ACN) on the h-LLE were discussed. Results showed that partition efficiency of 10-HDA depends on the phase ratio in both SALLE and SULLE. Though the partition triggered by NaCl and glucose is less efficient than MgSO4 in the 50% (v/v) ACN-water mixture, their extraction yields can be improved to be similar with that in MgSO4 SALLE by increasing the initial concentration of ACN in the ACN-water mixture. The content of co-extracted protein was correlated with water concentration in the obtained upper phase. MgSO4 showed the largest protein co-extraction at the low concentration of salt. Glucose exhibited a large protein co-extraction in the high phase ratio condition. Furthermore, NaCl with high initial ACN concentration is recommended because it produced high extraction yield for 10-HDA and the lowest amount of co-extracted protein. These observations would be valuable for the sample preparation of royal jelly. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Experimental and Model Studies on Continuous Separation of 2-Phenylpropionic Acid Enantiomers by Enantioselective Liquid-Liquid Extraction in Centrifugal Contactor Separators.

    Science.gov (United States)

    Feng, Xiaofeng; Tang, Kewen; Zhang, Pangliang; Yin, Shuangfeng

    2016-03-01

    Multistage enantioselective liquid-liquid extraction (ELLE) of 2-phenylpropionic acid (2-PPA) enantiomers using hydroxypropyl-β-cyclodextrin (HP-β-CD) as extractant was studied experimentally in a counter-current cascade of centrifugal contactor separators (CCSs). Performance of the process was evaluated by purity (enantiomeric excess, ee) and yield (Y). A multistage equilibrium model was established on the basis of single-stage model for chiral extraction of 2-PPA enantiomers and the law of mass conservation. A series of experiments on the extract phase/washing phase ratio (W/O ratio), extractant concentration, the pH value of aqueous phase, and the number of stages was conducted to verify the multistage equilibrium model. It was found that model predictions were in good agreement with the experimental results. The model was applied to predict and optimize the symmetrical separation of 2-PPA enantiomers. The optimal conditions for symmetric separation involves a W/O ratio of 0.6, pH of 2.5, and HP-β-CD concentration of 0.1 mol L(-1) at a temperature of 278 K, where eeeq (equal enantiomeric excess) can reach up to 37% and Yeq (equal yield) to 69%. By simulation and optimization, the minimum number of stages was evaluated at 98 and 106 for eeeq > 95% and eeeq > 97%. © 2016 Wiley Periodicals, Inc.

  4. Determination of strobilurin fungicides in cotton seed by combination of acetonitrile extraction and dispersive liquid-liquid microextraction coupled with gas chromatography.

    Science.gov (United States)

    Xue, Jiaying; Li, Huichen; Liu, Fengmao; Jiang, Wenqing; Chen, Xiaochu

    2014-04-01

    The simultaneous determination of four strobilurin fungicides (picoxystrobin, kresoxim-methyl, trifloxystrobin, and azoxystrobin) in cotton seed by combining acetonitrile extraction and dispersive liquid-liquid microextraction was developed prior to GC with electron capture detection. Several factors, including the type and volume of the extraction and dispersive solvents, extraction condition and time, and salt addition, were optimized. The analytes were extracted with acetonitrile from cotton seed and the clean-up was carried out by primary secondary amine. Afterwards, 60 μL of n-hexane/toluene (1:1, v/v) with a lower density than water was mixed with 1 mL of the acetonitrile extract, then the mixture was injected into 7 mL of distilled water. A 0.1 mL pipette was used to collect a few microliters of n-hexane/toluene from the top of the aqueous solution. The enrichment factors of the analytes ranged from 36 to 67. The LODs were in the range of 0.1 × 10(-3) -2 × 10(-3) mg/kg. The relative recoveries varied from 87.7 to 95.2% with RSDs of 4.1-8.5% for the four fungicides. The good performance of the method, compared with the conventional pretreatments, has demonstrated it is suitable for determining low concentrations of strobilurin fungicide residues in cotton seed. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Air-assisted liquid-liquid microextraction using floating organic droplet solidification for simultaneous extraction and spectrophotometric determination of some drugs in biological samples through chemometrics methods.

    Science.gov (United States)

    Farahmand, Farnaz; Ghasemzadeh, Bahar; Naseri, Abdolhossein

    2018-01-05

    An air assisted liquid-liquid microextraction by applying the solidification of a floating organic droplet method (AALLME-SFOD) coupled with a multivariate calibration method, namely partial least squares (PLS), was introduced for the fast and easy determination of Atenolol (ATE), Propanolol (PRO) and Carvedilol (CAR) in biological samples via a spectrophotometric approach. The analytes would be extracted from neutral aqueous solution into 1-dodecanol as an organic solvent, using AALLME. In this approach a low-density solvent with a melting point close to room temperature was applied as the extraction solvent. The emulsion was immediately formed by repeatedly pulling in and pushing out the aqueous sample solution and extraction solvent mixture via a 10-mL glass syringe for ten times. After centrifugation, the extractant droplet could be simply collected from the aqueous samples by solidifying the emulsion at a lower than the melting point temperature. In the next step, analytes were back extracted simultaneously into the acidic aqueous solution. Derringer and Suich multi-response optimization were utilized for simultaneous optimizing the parameters of three analytes. This method incorporates the benefits of AALLME and dispersive liquid-liquid microextraction considering the solidification of floating organic droplets (DLLME-SFOD). Calibration graphs under optimized conditions were linear in the range of 0.30-6.00, 0.32-2.00 and 0.30-1.40μg mL-1 for ATE, CAR and PRO, respectively. Other analytical parameters were obtained as follows: enrichment factors (EFs) were found to be 11.24, 16.55 and 14.90, and limits of detection (LODs) were determined to be 0.09, 0.10 and 0.08μg mL-1 for ATE, CAR and PRO, respectively. The proposed method will require neither a highly toxic chlorinated solvent for extraction nor an organic dispersive solvent in the application process; hence, it is more environmentally friendly. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. A rapid, accurate and sensitive method with the new stable isotopic tags based on microwave-assisted dispersive liquid-liquid microextraction and its application to the determination of hydroxyl UV filters in environmental water samples.

    Science.gov (United States)

    Li, Xiu; Chen, Guang; Liu, Jianjun; Liu, Yuxia; Zhao, Xianen; Cao, Ziping; Xia, Lian; Li, Guoliang; Sun, Zhiwei; Zhang, Shijuan; Wang, Hua; You, Jinmao

    2017-05-15

    A rapid, accurate and sensitive method, using the stable isotope labeling (SIL), microwave-assisted dispersive liquid-liquid micro extraction (MADLLME) and the ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), was developed and validated for the determination of hydroxyl UV Filters in environmental water samples. A pair of new isotopic tags D0-/D3-1-methylindole-3-acetic acid (D0-/D3-MIAA) is synthesized, with which a simple yet efficient pretreatment MADLLME-SIL is developed. Under the optimized conditions (80℃, 240W, 180s), the sample pretreatment including analyte extraction, pre-concentration and isotope labeling can be finished conveniently in only 9min. D0-/D3-MIAA labeling improves the chromatographic retention by strengthening the hydrophobicity and enhances the MS response for 3-4 orders of magnitude. Excellent linearity is established by the H/D ratios of 1/10-10/1 with the correlation coefficients >0.9990. The quite low detection limits (0.54-1.79ng/L) are achieved, ensuring the trace detection. This method is successfully applied to a series of environmental water samples. The recoveries (93.2%~103.5%) are significantly improved and the analysis time is largely reduced (filters in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Negative corona discharge-ion mobility spectrometry as a detection system for low density extraction solvent-based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Ebrahimi, Amir; Jafari, Mohammad T

    2015-03-01

    This paper deals with a method based on negative corona discharge ionization ion mobility spectrometry (NCD-IMS) for the analysis of ethion (as an organophosphorus pesticide). The negative ions such as O2(-) and NO(x)(-) were eliminated from the background spectrum to increase the instrument sensitivity. The method was used to specify the sample extracted via dispersive liquid-liquid microextraction (DLLME) based on low density extraction solvent. The ion mobility spectrum of ethion in the negative mode and the reduced mobility value for its ion peak are firstly reported and compared with those of the positive mode. In order to combine the low density solvent DLLME directly with NCD-IMS, cyclohexane was selected as the extraction solvent, helping us to have a direct injection up to 20 µL solution, without any signal interference. The method was exhaustively validated in terms of sensitivity, enrichment factor, relative recovery, and repeatability. The linear dynamic range of 0.2-100.0 µg L(-1), detection limit of 0.075 µg L(-1), and the relative standard deviation (RSD) of about 5% were obtained for the analysis of ethion through this method. The average recoveries were calculated about 68% and 92% for the grape juice and underground water, respectively. Finally, some real samples were analyzed and the feasibility of the proposed method was successfully verified by the efficient extraction of the analyte using DLLME before the analysis by NCD-IMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Microextraction by packed sorbent and salting-out-assisted liquid-liquid extraction for the determination of aromatic amines formed from azo dyes in textiles.

    Science.gov (United States)

    Sánchez, Miguel del Nogal; Santos, Patricia Martín; Sappó, Cristina Pérez; Pavón, José Luis Pérez; Cordero, Bernardo Moreno

    2014-02-01

    EU legislation prohibits the use of certain azo dyes which, on reduction, form any of 22 aromatic amines listed in Regulation (EC) 1907/2006 at concentrations above the threshold limit of 30 mg Kg(-1). Two different extraction techniques for the determination of aromatic amines formed from azo dyes in textiles in combination with gas chromatography-mass spectrometry (GC-MS) are described. The first one is based on microextraction by packed sorbent (MEPS) and the other approach involves salting-out-assisted liquid-liquid extraction (SALLE). The influence of several parameters on the efficiency of the extraction using MEPS (sorbent material, sample volume, elution solvent, elution volume and washing steps, among others) and SALLE (extraction volume and amount of salt) were investigated. In addition, chromatographic separation was optimized and quadrupole mass spectrometry was evaluated using the synchronous SIM/scan data acquisition mode. The repeatability (n=8, S/N=3) of the methods, calculated as the relative standard deviation (RSD) was below 15 and 11% for all compounds when MEPS and SALLE were used, respectively. Standard additions procedure was used to quantify the aromatic amines in the textil samples. The detection limits in the samples for both methods were lower than the maximum value allowed by legislation. The results obtained in the analysis of textiles revealed the presence of o-anisidine, p-chloroaniline, 4-chloro-o-toluidine, 2-naphthylamine and 3,3'-dimethoxybenzidine in some of them. © 2013 Elsevier B.V. All rights reserved.

  9. Benzyl and Methyl Fatty Hydroxamic Acids Based on Palm Kernel Oil as Chelating Agent for Liquid-Liquid Iron(III Extraction

    Directory of Open Access Journals (Sweden)

    Jamileh Amin

    2012-02-01

    Full Text Available Liquid-liquid iron(III extraction was investigated using benzyl fatty hydroxamic acids (BFHAs and methyl fatty hydroxamic acids (MFHAs as chelating agents through the formation of iron(III methyl fatty hydroxamate (Fe-MFHs or iron(III benzyl fatty hydroxamate (Fe-BFHs in the organic phase. The results obtained under optimized conditions, showed that the chelating agents in hexane extract iron(III at pH 1.9 were realized effectively with a high percentage of extraction (97.2% and 98.1% for MFHAs and BFHAs, respectively. The presence of a large amount of Mg(II, Ni(II, Al(III, Mn(II and Co(II ions did affect the iron(III extraction. Finally stripping studies for recovering iron(III from organic phase (Fe-MFHs or Fe-BFHs dissolved in hexane were carried out at various concentrations of HCl, HNO3 and H2SO4. The results showed that the desired acid for recovery of iron(III was 5 M HCl and quantitative recovery of iron(III was achieved from Fe(III-MFHs and Fe(III-BFHs solutions in hexane containing 5 mg/L of Fe(III.

  10. Benzyl and Methyl Fatty Hydroxamic Acids Based on Palm Kernel Oil as Chelating Agent for Liquid-Liquid Iron(III) Extraction

    Science.gov (United States)

    Haron, Md Jelas; Jahangirian, Hossein; Silong, Sidik; Yusof, Nor Azah; Kassim, Anuar; Rafiee-Moghaddam, Roshanak; Mahdavi, Behnam; Peyda, Mazyar; Abdollahi, Yadollah; Amin, Jamileh

    2012-01-01

    Liquid-liquid iron(III) extraction was investigated using benzyl fatty hydroxamic acids (BFHAs) and methyl fatty hydroxamic acids (MFHAs) as chelating agents through the formation of iron(III) methyl fatty hydroxamate (Fe-MFHs) or iron(III) benzyl fatty hydroxamate (Fe-BFHs) in the organic phase. The results obtained under optimized conditions, showed that the chelating agents in hexane extract iron(III) at pH 1.9 were realized effectively with a high percentage of extraction (97.2% and 98.1% for MFHAs and BFHAs, respectively). The presence of a large amount of Mg(II), Ni(II), Al(III), Mn(II) and Co(II) ions did affect the iron(III) extraction. Finally stripping studies for recovering iron(III) from organic phase (Fe-MFHs or Fe-BFHs dissolved in hexane) were carried out at various concentrations of HCl, HNO3 and H2SO4. The results showed that the desired acid for recovery of iron(III) was 5 M HCl and quantitative recovery of iron(III) was achieved from Fe(III)-MFHs and Fe(III)-BFHs solutions in hexane containing 5 mg/L of Fe(III). PMID:22408444

  11. Solid-Phase Extraction Followed by Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Parabens.

    Science.gov (United States)

    Hashemi, Beshare; Shamsipur, Mojtaba; Fattahi, Nazir

    2015-09-01

    A dispersive liquid-liquid microextraction based on solidification of floating organic drop method combined with solid-phase extraction (500-mg C18 sorbent) was developed for preconcentration and determination of some parabens. The experimental parameters influencing the extraction efficiency such as the type of extraction and disperser solvents, as well as their volumes, breakthrough volume, flow rate and salt addition were studied and optimized. The optimum experimental conditions found included: sample volume, 100 mL; KCl concentration, 1% (w/v); extraction solvent (1-undecanol) volume, 20 µL and disperser solvent (acetone) volume, 250 µL. Under the optimum experimental conditions, calibration graphs were linear in the range of 1-200 µg L(-1) with limits of detection ranged from 0.3 to 1.7 µg L(-1). The relative standard deviations were in the range of 1.2-3.1% (n = 5). The enrichment factors and absolute recoveries of parabens in different matrices were 245-1886 and 9.0-69.8%, respectively. The method was applied to the simultaneous determination of parabens in different matrices. The relative recoveries from water, shampoo and mouth rinse samples, which have been spiked at different levels of parabens, were 87.83-112.25%, 82.80-108.40% and 90.10-97.60%, respectively. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Feasibility of dispersive liquid-liquid microextraction for extraction and preconcentration of Cu and Fe in red and white wine and determination by flame atomic absorption spectrometry

    Science.gov (United States)

    Seeger, Tassia S.; Rosa, Francisco C.; Bizzi, Cezar A.; Dressler, Valderi L.; Flores, Erico M. M.; Duarte, Fabio A.

    2015-03-01

    A method for extraction and preconcentration of Cu and Fe in red and white wines using dispersive liquid-liquid microextraction (DLLME) and determination by flame atomic absorption spectrometry (F AAS) was developed. Extraction was performed using sodium diethyldithiocarbamate as chelating agent and a mixture of 40 μL of 1,2-dichlorobenzene (extraction solvent) and 900 μL of methanol (dispersive solvent). Some parameters that influencing the extraction efficiency such as pH (2 to 5), concentration of chelating agent (0 to 2%), effect of salt addition (0 to 10%), number of washing steps (1 to 4) and centrifugation time (0 to 15 min) were studied. Accuracy was evaluated after microwave-assisted digestion in closed vessels and analytes were determined by inductively coupled plasma optical emission spectrometry. Agreement with the proposed method ranged from 91 to 110 and from 89 to 113% for Cu and Fe, respectively. Calibration of F AAS instrument was performed using analyte addition method and limits of detection were 6.3 and 2.4 μg L- 1 for Cu and Fe, respectively. The proposed method was applied for the determination of Cu and Fe in five samples of red wine and three samples of white wine, with concentration ranging from 21 to 178 μg L- 1 and from 1.38 to 3.74 mg L- 1, respectively.

  13. Solid-phase extraction followed by dispersive liquid-liquid microextraction for the sensitive determination of ecstasy compounds and amphetamines in biological samples

    Directory of Open Access Journals (Sweden)

    H. A. Mashayekhi

    2014-09-01

    Full Text Available A novel approach for the determination of ecstasy and amphetamines (3,4-methylenedioxymethylamphetamine (MDMA, Ecstasy, 3,4-methylenedioxyamphetamine (MDA, 3,4-methylenedioxyethylamphetamine (MDEA and 3,4-methylenedioxypropylamphetamine (MDPA in biological samples is presented. The analytes were extracted from the matrix and transferred to a small volume of a high density, water insoluble solvent using solid-phase extraction (SPE followed by dispersive liquid-liquid microextraction (DLLME. This combination not only resulted in a high enrichment factor, but also it could be used in complex matrices (biological samples. Some important extraction parameters, such as sample solution flow rate, sample pH, type and volume of extraction and disperser solvents as well as the salt addition, were studied and optimized. Under the optimized conditions, the calibration graphs were linear in the range of 0.5-500 µg L-1 and 1.0-500 µg L-1 with detection limits in the range of 0.1-0.3 µg L-1 and 0.2-0.7 µg L-1 in urine and plasma samples, respectively. The results showed that SPE-DLLME is a suitable method for the determination of ecstasy components and amphetamines in biological and water samples. DOI: http://dx.doi.org/10.4314/bcse.v28i3.3

  14. Chemometric assisted ultrasound leaching-solid phase extraction followed by dispersive-solidification liquid-liquid microextraction for determination of organophosphorus pesticides in soil samples.

    Science.gov (United States)

    Ahmadi, Kamyar; Abdollahzadeh, Yaser; Asadollahzadeh, Mehdi; Hemmati, Alireza; Tavakoli, Hamed; Torkaman, Rezvan

    2015-05-01

    Ultrasound leaching-solid phase extraction (USL-SPE) followed by dispersive-solidification liquid-liquid microextraction (DSLLME) was developed for preconcentration and determination of organophosphorus pesticides (OPPs) in soil samples prior gas chromatography-mass spectrometry analysis. At first, OPPs were ultrasonically leached from soil samples by using methanol. After centrifugation, the separated methanol was diluted to 50 mL with double-distillated water and passed through the C18 SPE cartridge. OPPs were eluted with 1 mL acetonitrile. Thus, 1 mL acetonitrile extract (disperser solvent) and 10 µL 1-undecanol (extraction solvent) were added to 5 mL double-distilled water and a DSLLME technique was applied. The variables of interest in the USL-SPE-DSLLME method were optimized with the aid of chemometric approaches. First, in screening experiments, fractional factorial design (FFD) was used for selecting the variables which significantly affected the extraction procedure. Afterwards, the significant variables were optimized using response surface methodology (RSM) based on central composite design (CCD). Under the optimum conditions, the enrichment factors were 6890-8830. The linear range was 0.025-625 ng g(-1) and limits of detection (LODs) were between 0.012 and 0.2 ng g(-1). The relative standard deviations (RSDs) were in the range of 4.06-8.9% (n=6). The relative recoveries of OPPs from different soil samples were 85-98%. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. In-sample acetylation-non-porous membrane-assisted liquid-liquid extraction for the determination of parabens and triclosan in water samples.

    Science.gov (United States)

    Villaverde-de-Sáa, Eugenia; González-Mariño, Iria; Quintana, José Benito; Rodil, Rosario; Rodríguez, Isaac; Cela, Rafael

    2010-07-01

    A procedure for the determination of seven parabens (esters of 4-hydroxybenzoic acid), including the distinction between branched and linear isomers of propyl- and butyl-parabens and triclosan in water samples, was developed and evaluated. The procedure includes in-sample acetylation-non-porous membrane-assisted liquid-liquid extraction and large volume injection-gas chromatography-ion trap-tandem mass spectrometry. Different derivatisation strategies were considered, i.e. post-extraction silylation with N-methyl-N-(tert-butyldimethylsilyl)-trifluoroacetamide and in situ acylation with acetic anhydride (Ac(2)O) and isobutylchloroformate. Moreover, acceptor solvent and the basic catalyser of the acylation reaction were investigated. Thus, in situ derivatisation with Ac(2)O and potassium hydrogenphosphate (as basic catalyser) was selected. Potassium hydrogenphosphate overcomes some drawbacks of other basic catalysers, e.g. toxicity and bubble formation, while leads to higher responses. Subsequently, other experimental variables affecting derivatisation-extraction yield such as pre-stirring time, salt addition and volume of Ac(2)O were optimised by an experimental design approach. Under optimised conditions, the proposed method achieved detection limits from 0.1 to 1.4 ng L(-1) for a sample volume of 18 mL and extraction efficiencies, estimated by comparison with liquid-liquid extraction, between 46% (for methyl- and ethyl-parabens) and 110% (for benzylparaben). The reported sample preparation approach is free of matrix effects for parabens but affected for triclosan with a reduction of approximately 40% when wastewater samples are analysed; therefore, both internal and external calibration can be used as quantification techniques for parabens, but internal standard calibration is mandatory for triclosan. The application of the method to real samples revealed the presence of these compounds in raw wastewater at concentrations up to 26 ng mL(-1), the prevalence of the

  16. Rapid determination of phthalate esters in alcoholic beverages by conventional ionic liquid dispersive liquid-liquid microextraction coupled with high performance liquid chromatography.

    Science.gov (United States)

    Fan, Yingying; Liu, Shuhui; Xie, Qilong

    2014-02-01

    A very simple, fast and environmentally friendly sample extraction method was proposed for the analysis of phthalate esters (PAEs, di-isobutyl phthalate (DIBP), dibutylphthalate (DBP), butylbenzylphthalate (BBP) and bis(2-ethylhexyl)phthalate (DEHP)) in alcoholic beverages by using conventional ionic liquid dispersive liquid-liquid microextraction. The samples were extracted by 160 μL 1-octyl-3-methylimidazolium hexafluorophosphate in the presence of appropriate amount of ethanol and 10% (w/v) sodium chloride solution; the enriched analytes in sedimented phases were analyzed by high performance liquid chromatography-diode array detector (HPLC-DAD). Under the optimum conditions, a satisfactory linearity (in the range of 0.02-1 μg mL(-1) for white spirits and 0.01-0.5 μg mL(-1) for red wines with the correlation coefficients (r) varying from 0.9983 to 1), acceptable recovery rates (88.5-103.5% for white spirits and 91.6-104.6% for red wines), good repeatability (RSD ≤ 8.0%) and low detection limits (3.1-4.2 ng mL(-1) for white spirits and 1.5-2.2 ng mL(-1) for red wines) were obtained. The developed method was successfully applied for the determination of the four PAEs in 30 white spirits and 11 red wines collected locally, and the DBP content in 63% (19:30) white spirits exceeded the specific migration limit of 0.3 mg kg(-1) established by international regulation. © 2013 Elsevier B.V. All rights reserved.

  17. Ultrasound-Assisted Low-Density Solvent Dispersive Liquid-Liquid Extraction for the Determination of Amphetamines in Biological Samples Using Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Liang Meng

    2015-01-01

    Full Text Available In order to control drug crime effectively, it is necessary to develop selective analytical methods suitable for unambiguous identification and determination of drugs in illicit samples and biological matrices. A novel microextraction technique based on ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction, (UA-LDS-DLLME has been applied to the determination of four amphetamines (methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyamphetamine in urine samples by gas chromatography-mass spectrometry. The parameters affecting extraction efficiency have been investigated and optimized. UA-LDS-DLLME used ultrasound energy to assist in the emulsification process without any disperser solvent. Under the optimized conditions, linearity was observed for all analytes in the 0.15–10 μg/mL range with correlation coefficients (R ranging from 0.9886 to 0.9894. The recoveries of 75.6–91.4% with relative standard deviations of 2.5–4.0% were obtained. The limits of detection (S/N = 3 were estimated to be in the 5–10 ng/mL range. The UA-LDS-DLLME technique had the advantages of shorter extraction time, suitability for simultaneous pretreatments of batches of samples, and the higher extraction efficiency. It was successfully applied to the analysis of amphetamines in real human urine samples.

  18. [Determination of capsaicinoids and eugenol in waste-edible-oil by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Zhang, Zhong; Ren, Fei; Zhang, Pan

    2012-11-01

    A method was developed for the determination of capsaicinoids (capsaicin, dihydrocapsaicin and synthetic capsaicin) and eugenol in waste-edible-oil extracted by liquid-liquid extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The capsaicinoids and eugenol in waste-edible-oil were extracted by methanol, and then separated by a SUPEL COSIL ABZ + Plus dC18 column (150 mm x4.6 mm, 5 microm). The analysis was performed by MS/MS with electrospray ionization in positive and negative ion modes with multiple reaction monitoring (MRM). The limits of detection for capsaicin, dihydrocapsaicin, synthetic capsaicin and eugenol were 0.02, 0.03, 0.03 and 0.6 microg/L, respectively. The good linear relationships were obtained in certain concentration ranges of capsaicinoids and eugenol. The relative standard deviations (RSDs, n=5) of same-worker and different-worker were less than 5%. The method is exclusive, sensitive and accurate, and can be used in waste-edible-oil determination.

  19. Salting-out assisted liquid-liquid extraction and partial least squares regression to assay low molecular weight polycyclic aromatic hydrocarbons leached from soils and sediments

    Science.gov (United States)

    Bressan, Lucas P.; do Nascimento, Paulo Cícero; Schmidt, Marcella E. P.; Faccin, Henrique; de Machado, Leandro Carvalho; Bohrer, Denise

    2017-02-01

    A novel method was developed to determine low molecular weight polycyclic aromatic hydrocarbons in aqueous leachates from soils and sediments using a salting-out assisted liquid-liquid extraction, synchronous fluorescence spectrometry and a multivariate calibration technique. Several experimental parameters were controlled and the optimum conditions were: sodium carbonate as the salting-out agent at concentration of 2 mol L- 1, 3 mL of acetonitrile as extraction solvent, 6 mL of aqueous leachate, vortexing for 5 min and centrifuging at 4000 rpm for 5 min. The partial least squares calibration was optimized to the lowest values of root mean squared error and five latent variables were chosen for each of the targeted compounds. The regression coefficients for the true versus predicted concentrations were higher than 0.99. Figures of merit for the multivariate method were calculated, namely sensitivity, multivariate detection limit and multivariate quantification limit. The selectivity was also evaluated and other polycyclic aromatic hydrocarbons did not interfere in the analysis. Likewise, high performance liquid chromatography was used as a comparative methodology, and the regression analysis between the methods showed no statistical difference (t-test). The proposed methodology was applied to soils and sediments of a Brazilian river and the recoveries ranged from 74.3% to 105.8%. Overall, the proposed methodology was suitable for the targeted compounds, showing that the extraction method can be applied to spectrofluorometric analysis and that the multivariate calibration is also suitable for these compounds in leachates from real samples.

  20. Vortex-assisted liquid-liquid micro-extraction and high-performance liquid chromatography for a higher sensitivity methyl methacrylate determination in biological matrices.

    Science.gov (United States)

    Sousa, Tiago F A; Aniceto, Marta C; Amorim, Célia G; Souto-Lopes, Mariana; Pérez-Mongiovi, Daniel; Montenegro, Maria C B S M; Araújo, Alberto N

    2014-05-01

    A vortex-assisted liquid-liquid micro-extraction coupled with high-performance liquid chromatography, with UV-vis, is proposed to pre-concentrate methyl methacrylate and to improve separation in biological matrices. The use of 1-octanol as extracting phase, its volume, the need for a dispersant agent, the agitation conditions and the cooling time before phase separation were evaluated. In optimum conditions, enrichment factors of 20 (±0.5) and enrichment recovery of 99% were obtained. The straightforward association of this extraction process with the HPLC method, previously regulated by the International Organization for Standardization, afforded a detection limit of 122 ng/mL and a quantification limit of 370 ng/mL. The within-batch precision, relative standard deviation, was 3% for a sample with 1.49 µg/mL and 4% for a sample with 13.4 µg/mL. The results showed a between batch-precision of 21% for experiments performed on five different days, for a sample with a concentration of 1.10 µg/mL in methyl methacrylate. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Separation and Recycling for Rare Earth Elements by Homogeneous Liquid-Liquid Extraction (HoLLE Using a pH-Responsive Fluorine-Based Surfactant

    Directory of Open Access Journals (Sweden)

    Shotaro Saito

    2015-08-01

    Full Text Available A selective separation and recycling system for metal ions was developed by homogeneous liquid-liquid extraction (HoLLE using a fluorosurfactant. Sixty-two different elemental ions (e.g., Ag, Al, As, Au, B, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, In, Ir, La, Lu, Mg, Mn, Mo, Nb, Nd, Ni, Os, P, Pb, Pd, Pr, Pt, Re, Rh, Ru, Sb, Sc, Se, Si, Sm, Sn, Sr, Ta, Tb, Te, Ti, Tl, Tm, V, W, Y, Yb, Zn, and Zr were examined. By changing pH from a neutral or alkaline solution (pH ≥ 6.5 to that of an acidic solution (pH < 4.0, gallium, zirconium, palladium, silver, platinum, and rare earth elements were extracted at >90% efficiency into a sedimented Zonyl FSA® (CF3(CF2n(CH22S(CH22COOH, n = 6–8 liquid phase. Moreover, all rare earth elements were obtained with superior extraction and stripping percentages. In the recycling of rare earth elements, the sedimented phase was maintained using a filter along with a mixed solution of THF and 1 M sodium hydroxide aqueous solution. The Zonyl FSA® was filtrated and the rare earth elements were recovered on the filter as a hydroxide. Furthermore, the filtrated Zonyl FSA was reusable by conditioning the subject pH.

  2. Determination of carbohydrates in tobacco by pressurized liquid extraction combined with a novel ultrasound-assisted dispersive liquid-liquid microextraction method.

    Science.gov (United States)

    Cai, Kai; Hu, Deyu; Lei, Bo; Zhao, Huina; Pan, Wenjie; Song, Baoan

    2015-07-02

    A novel derivatization-ultrasonic assisted-dispersive liquid-liquid microextraction (UA-DLLME) method for the simultaneous determination of 11 main carbohydrates in tobacco has been developed. The combined method involves pressurized liquid extraction (PLE), derivatization, and UA-DLLME, followed by the analysis of the main carbohydrates with a gas chromatography-flame ionization detector (GC-FID). First, the PLE conditions were optimized using a univariate approach. Then, the derivatization methods were properly compared and optimized. The aldononitrile acetate method combined with the O-methoxyoxime-trimethylsilyl method was used for derivatization. Finally, the critical variables affecting the UA-DLLME extraction efficiency were searched using fractional factorial design (FFD) and further optimized using Doehlert design (DD) of the response surface methodology. The optimum conditions were found to be 44 μL for CHCl3, 2.3 mL for H2O, 11% w/v for NaCl, 5 min for the extraction time and 5 min for the centrifugation time. Under the optimized experimental conditions, the detection limit of the method (LODs) and linear correlation coefficient were found to be in the range of 0.06-0.90 μg mL(-1) and 0.9987-0.9999. The proposed method was successfully employed to analyze three flue-cured tobacco cultivars, among which the main carbohydrate concentrations were found to be very different. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Use of magnetic effervescent tablet-assisted ionic liquid dispersive liquid-liquid microextraction to extract fungicides from environmental waters with the aid of experimental design methodology.

    Science.gov (United States)

    Yang, Miyi; Wu, Xiaoling; Jia, Yuhan; Xi, Xuefei; Yang, Xiaoling; Lu, Runhua; Zhang, Sanbing; Gao, Haixiang; Zhou, Wenfeng

    2016-02-04

    In this work, a novel effervescence-assisted microextraction technique was proposed for the detection of four fungicides. This method combines ionic liquid-based dispersive liquid-liquid microextraction with the magnetic retrieval of the extractant. A magnetic effervescent tablet composed of Fe3O4 magnetic nanoparticles, sodium carbonate, sodium dihydrogen phosphate and 1-hexyl-3-methylimidazolium bis(trifluoromethanesulfonimide) was used for extractant dispersion and retrieval. The main factors affecting the extraction efficiency were screened by a Plackett-Burman design and optimized by a central composite design. Under the optimum conditions, good linearity was obtained for all analytes in pure water model and real water samples. Just for the pure water, the recoveries were between 84.6% and 112.8%, the limits of detection were between 0.02 and 0.10 μg L(-1) and the intra-day precision and inter-day precision both are lower than 4.9%. This optimized method was successfully applied in the analysis of four fungicides (azoxystrobin, triazolone, cyprodinil, trifloxystrobin) in environmental water samples and the recoveries ranged between 70.7% and 105%. The procedure promising to be a time-saving, environmentally friendly, and efficient field sampling technique. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Analysis of biogenic amines in wines by salting-out assisted liquid-liquid extraction and high-performance liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Ramos, Rui Miguel; Valente, Inês Maria; Rodrigues, José António

    2014-06-01

    Biogenic amines are nitrogenous organic compounds of low molecular weight that are either formed or metabolized in cells of living organisms and can be found in several food products, being produced mainly by amino acid decarboxylation. When ingested in high concentrations they can induce several health problems in humans. In alcoholic beverages, and especially in wine, they are formed during the vinification process as a result of the action of microorganisms. In this work it is proposed a new methodology for the determination of biogenic amines in wines, which includes a sample preparation approach based on salting-out assisted liquid-liquid extraction, the use of dansyl chloride for the derivatization and chromatographic separation by high-performance liquid chromatography with fluorimetric detection. The salting-out effect is used to promote phase separation between water and a water-miscible organic solvent, while improving the extraction of organic or inorganic species. Several extraction parameters were optimized, such as the dansyl chloride concentration, pH and the effects caused by the order in which the extraction and derivatization were performed. Extraction of amines, and consequent detection, depends on the presence of dansyl chloride in solution prior to extraction. The results showed the possibility to simultaneously perform the extraction and the derivatization, making sample preparation easier and less time-consuming. The methodology was successfully applied to the determination of biogenic amines in five wines (white, red and rosé). This method has the potential to be a good alternative to existing methods since it is cheaper, easier and simplifies the sample preparation step. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Separation by liquid-liquid extraction of actinides(III) from lanthanides(III) using new molecules: the picolinamides; Separation par extraction liquide-liquide des actinides(III) des lanthanides(III) par de nouvelles molecules: les picolinamides

    Energy Technology Data Exchange (ETDEWEB)

    Cordier, P.Y. [CEA Marcoule, Departement de Recherche en Retraitement et en Vitrification, 30 - Bagnols-sur-Ceze (France)]|[Clermont-Ferrand-2 Univ., 63 - Aubiere (France)

    1996-07-01

    In the field of long-lived radionuclides separation from waste generated during spent fuel reprocessing, the picolinamides have been chosen as potential extractants for the selective extraction of actinides (III) from lanthanides (III). The first studies initiated on the most simple molecule of the picolinamide family, namely 2-pyridinecarboxamide, pointed out that in an aqueous media the complexation stability constant between this ligand and Am(III) is roughly 10 times higher than the ones corresponding to Ln(III). The synthesis of lipophilic derivatives of 2-pyridinecarboxamide leaded to extraction experiments. The extraction of metallic cation by lipophilic picolinamides, according to a solvatation mechanism, is strongly dependent on the nature of the amide function: a primary amide function (group I) leads to a good extraction; on the contrary, there is a decrease for secondary (group II) and tertiary (group III) amide functions. From a theoretical point of view, this work leads finally to the following conclusions: confirmation of the importance of the presence of soft donor atoms within the extractants (nitrogen in our case) for An(III)/Ln(III). Also, sensitivity of this soft donor atom regarding the protonation reaction; prevalence in our case of the affinity of the extractant for the metallic cation over the lipophilia of the extractant to ensure good distribution coefficients. The extraction and Am(III)/Ln(III) separation performances of the picolinamides from pertechnetic media leads to the design of a possible flowsheet for the reprocessing of high level liquid waste, with the new idea of an integrated technetium reflux. (author) 105 refs.

  6. Salting-out assisted liquid-liquid extraction coupled to ultra-high performance liquid chromatography-tandem mass spectrometry for the determination of tetracycline residues in infant foods.

    Science.gov (United States)

    Moreno-González, David; García-Campaña, Ana M

    2017-04-15

    The use of salting-out assisted liquid-liquid extraction (SALLE) combined with ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) has been evaluated for the determination of tetracyclines in infant foods based on meat and vegetables or in milk. To obtain satisfactory extraction efficiencies for the studied analytes, several parameters affecting the SALLE procedure were optimized. Analytical performances of the method were satisfactory, obtaining limits of quantification lower than 0.48μgkg -1 in all cases. The precision, expressed as relative standard deviation (%, RSD) was below 11.3%. The extraction efficiency for fortified samples ranged from 89.2 to 96.8%, with RSDs lower than 7.3%. Matrix effect was evaluated for all samples studied, being lower than |21|% in all cases. In relation to the low solvent consumption, the proposed methodology could be considered rapid, cheap and environmentally friendly. Its applicability has been successfully tested in a wide range of infant foods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. A novel extraction method for β-carotene and other carotenoids in fruit juices using air-assisted, low-density solvent-based liquid-liquid microextraction and solidified floating organic droplets.

    Science.gov (United States)

    Sricharoen, Phitchan; Limchoowong, Nunticha; Techawongstien, Suchila; Chanthai, Saksit

    2016-07-15

    Green extraction using air-assisted, low-density solvent-based liquid-liquid microextraction and solidified floating organic droplets (AA-LDS-LLME-SFOD) prior to spectrophotometry was successfully applied for quantitation of carotenoids in fruit juices. Under optimal conditions, β-carotene could be quantified with a linear response up to a concentration of 60 μg mL(-1). The procedure was performed in a microcentrifuge tube with 40 μL of 1-dodecanol as the extraction solvent and a 1.0 mL juice sample containing 8% NaCl under seven extraction cycles of air pumping by syringe. This method was validated based on linearity (0.2-30 μg mL(-1), R(2) 0.998), limit of detection (0.04 μg mL(-1)) and limit of quantification (0.13 μg mL(-1)). The precision, expressed as the relative standard deviation (RSD) of the calibration curve slope (n=12), for inter-day and intra-day analysis was 4.85% and 7.92%, respectively. Recovery of β-carotene was in the range of 93.6-101.5%. The newly proposed method is simple, rapid and environmentally friendly, particularly as a useful screening test for food analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Isopropyl-3-pentadecylphenyl phosphoric acid - a new reagent for liquid-liquid extraction and separation of rare earths

    Energy Technology Data Exchange (ETDEWEB)

    Sreelatha, S.; Prasada Rao, T.; Narayanan, C.S.; Damodaran, A.D. (Regional Research Lab., Trivandrum (India))

    1993-03-01

    A new reagent isopropyl-3-pentadecylphenyl phosphoric acid (IPPA = HR) was synthesized from cardanol [I-37, 300-39-5] and was used to investigate the extraction behavior of lanthanum(III), europium(III) and lutetium(III) from HCl and HClO[sub 4] solutions into toluene. The species extracted were found to be Ln(HR[sub 2])[sub 3] (where Ln = La(III) or Eu(III) or Lu(III)). The extraction behavior of above lanthanides has also been compared with yttrium and other rare earths. It was observed that the extraction increases with increase of atomic number of rare earths. In addition the extraction efficiency of IPPA has been compared with well known acidic organophosphorus extractants like di-2-ethylhexyl phosphoric acid (DEHPA) and 2-ethylhexyl-mono-2-ethylhexyl phosphoric acid (EHEHPA). 6 refs., 5 figs., 3 tabs.

  9. [Simultaneous determination of 23 ester compounds in cigarette water-borne adhesives by liquid-liquid extraction and gas chromatography-mass spectrometry].

    Science.gov (United States)

    Gong, Shuguo; Kong, Bo; Tuo, Suxing; Dai, Yunhui; Wu, Mingjian; Tan, Liquan; Liu, Wei

    2013-10-01

    A method of gas chromatography-mass spectrometry (GC-MS) with liquid-liquid extraction has been developed for the simultaneous determination of 23 ester compounds including acetate esters, acrylic esters, metacrylic acid esters and phthalate acid esters in cigarette water-borne adhesives. After dispersed in water, the sample was extracted by n-hexane solution containing phenyl ethyl propionate as internal standard substance. Then, the solution was centrifuged and filtrated through a 0.45 microm organic membrane filter. Finally, the solution was separated on a DB-WAXETR column (60 m x 0.25 mm x 0.25 microm), and detected with MS in selected ion monitoring mode, and quantified by internal standard method. The results showed a good linear correlation in the range of 0.4-50.0 mg/L. The recoveries of the ester compounds spiked in the sample were 81.8%-109.1%, and the relative standard deviations (RSDs, n = 5) were less than 4%. The limits of detection (LODs) and limits of quantification (LOQs were in the ranges of 0.02-0.76 mg/kg and 0.04-2.52 mg/kg, respectively. The method is simple, time-saving, and has high sensitivity and good reproducibility. It can be applied to the determination of the 23 ester compounds in cigarette water-borne adhesives.

  10. Determination of phthalate esters in distillates by ultrasound-vortex-assisted dispersive liquid-liquid micro-extraction (USVADLLME) coupled with gas chromatography/mass spectrometry.

    Science.gov (United States)

    Montevecchi, Giuseppe; Masino, Francesca; Zanasi, Luca; Antonelli, Andrea

    2017-04-15

    A method for the extraction of phthalate esters (PAEs) by Ultrasound-Vortex-Assisted Dispersive Liquid-Liquid Micro-Extraction (USVADLLME) approach was optimised and applied for the first time to a historical series of brandies. These contaminants are widely spread in the environment as a consequence of about half century of use in different fields of applications. The concern about these substances and the recent legal restrictions of China in distillates import need a quick and sensitive method for their quantification. The proposed method, moreover, is environmentally oriented due to the disposal of micro-quantities of solvent required. In fact, sub-ppm-limits of detection were achieved with a solvent volume as low as 160μL. The analysed samples were within the legal limits, except for some very ancient brandies whose contamination was probably due to a PAEs concentration effect as a consequence of long ageing and for the use of plastic pipelines no more operative. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Intravascular Residence Time Determination for the Cyanide Antidote Dimethyl Trisulfide in Rat by Using Liquid-Liquid Extraction Coupled with High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Deepthika De Silva

    2016-01-01

    Full Text Available These studies represent the first report on the intravascular residence time determinations for the cyanide antidote dimethyl trisulfide (DMTS in a rat model by using high performance liquid chromatography coupled with ultraviolet absorption spectroscopy (HPLC-UV. The newly developed sample preparation included liquid-liquid extraction by cyclohexanone. The calibration curves showed a linear response for DMTS concentrations between 0.010 and 0.30 mg/mL with R2 = 0.9994. The limit of detection for DMTS via this extraction method was 0.010 mg/mL, and the limit of quantitation was 0.034 mg/mL. Thus this calibration curve provided a tool for determining DMTS in the range between 0.04 and 0.30 mg/mL. Rats were given 20 mg/kg DMTS dose (in 15% Polysorbate 80 intravenously, and blood samples were taken 15, 60, 90, 120, and 240 min after DMTS injections. The data points were plotted as DMTS concentration in RBCs versus time, and the intravascular residence time was determined graphically. The results indicated a half-life of 36 min in a rat model, suggesting that the circulation time is long enough to provide a reasonable time interval for cyanide antagonism.

  12. Capillary liquid chromatography combined with pressurized liquid extraction and dispersive liquid-liquid microextraction for the determination of vitamin E in cosmetic products.

    Science.gov (United States)

    Viñas, Pilar; Pastor-Belda, Marta; Campillo, Natalia; Bravo-Bravo, María; Hernández-Córdoba, Manuel

    2014-06-01

    Capillary liquid chromatography (LC) is used for the determination of tocopherols and tocotrienols in cosmetic products. Dispersive liquid-liquid microextraction (DLLME) allows the analytes to be preconcentrated into a very small volume of organic solvent which is then injected into the chromatograph running at a very low flow rate. Pressurized liquid extraction (PLE) at a high temperature and pressure was used to isolate vitamin E forms from cosmetics. The Taguchi experimental method was used to optimize the factors affecting DLLME. The parameters selected were 2mL of acetonitrile (disperser solvent), 100μL carbon tetrachloride (extraction solvent) and 10mL aqueous solution. A volume of 5μL of the organic phase was injected into the reversed-phase capillary LC system equipped with a diode array detector and using an isocratic mobile phase composed of an 95:5 (v/v) methanol:water mixture at a flow-rate of 20μLmin(-1). Quantification was carried out using aqueous standards and detection limits were in the range 0.1-0.5ngmL(-1), corresponding to 3-15ngg(-1) in the cosmetic sample. The recoveries were in the 87-105% range, with RSDs lower than 7.8%. The method was validated according to international guidelines and using a certified reference material. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Simultaneous determination of three estrogens in human saliva without derivatization or liquid-liquid extraction for routine testing via miniaturized solid phase extraction with LC-MS/MS detection.

    Science.gov (United States)

    Li, Xiaoguang Sunny; Li, Shu; Kellermann, Gottfried

    2018-02-01

    Accurate quantitation of estrogens (i.e, estrone (E1), estradiol (E2) and estriol (E3)) is valuable for clinical assessment of human health and disease. Alterations in estrogen levels have been implicated in numerous pathological conditions. However, inadequacies in sensitivity and specificity, cumbersome sample preparation and invasive specimen collection hamper the usability of available methods for clinical applications. Herein, a simple, rapid, highly sensitive and specific LC-MS/MS method was developed and validated for the simultaneous determination of three estrogens in human saliva providing a non-invasive alternative to conventional blood samples. For the first time, a 96-well hydrophilic-lipophilic-balanced (HLB) microplate was employed for clean-up and enrichment of estrogens in a single extraction without the requirements of derivatization, evaporation, liquid-liquid extraction and online extraction. A rapid LC chromatographic separation with a turnaround time of 5.0min was achieved on a BEH C18 XP column. The use of 0.1mM ammonium fluoride (NH4F) as LC additive, and integration of summated and scheduled multiple reaction monitoring (MRM) transitions substantially improved the sensitivity to 1pg/mL, allowing the accurate quantitation of trace levels of three estrogens in one run. The assay was fully validated with good performance for extraction efficiency (67.0-85.6%), matrix effect (89.6-100.2%), linearity (from 1.0pg/mL up to 1000pg/mL), accuracy (98.9-112.4%) and precision (≤7.4%). Additionally, the assay was unaffected by 34 structurally-similar, potentially interfering substances tested at high clinical concentrations. The applicability of the assay was demonstrated by assessing the reference intervals of authentic saliva samples from healthy adult males, pre- and post-menopausal females. The easy sample preparation, fast LC and multi-analyte MS/MS detection utilizing noninvasive saliva as a specimen delivers a simple, practical, sensitive and

  14. Ionic liquid-based dispersive liquid-liquid microextraction combined with functionalized magnetic nanoparticle solid-phase extraction for determination of industrial dyes in water.

    Science.gov (United States)

    Liang, Ning; Hou, Xiaohong; Huang, Peiting; Jiang, Chao; Chen, Lijuan; Zhao, Longshan

    2017-10-23

    N-butyl pyridinium bis((trifluoromethyl)sulfonyl)imide ([Hpy]NTf2) functionalized core/shell magnetic nanoparticles (MNPs, Fe3O4@SiO2@[Hpy]NTf2)) were prepared and applied as an adsorbent for magnetic solid phase extraction (MSPE) of three commonly used industrial dyes including malachite green, crystal violet and methylene blue. Extraction solution was mixed with 100 mg extraction material of Fe3O4@SiO2@[Hpy]NTf2, and 1 mL of acetonitrile was used to elute target analytes for further extraction and purification. [Hpy]NTf2 was used as extraction solution, and 500 μL methanol was selected as dispersive solvent in ionic liquid (IL) dispersive liquid-liquid microextraction (DLLME) method. After sonication for 5 min and centrifugation at 447 g for 10 min, 20 μL of sedimented phase was injected into HPLC-UV system. The limit of detection (LOD) and limit of quantification (LOQ) of current method were 0.03 and 0.16 μg·L(-1), respectively, which indicated the sensitivity was comparable or even superior to other reported methods. The relative recoveries of the target analytes ranged from 86.1% to 100.3% with relative standard deviations between 0.3% and 4.5%. The developed method has been successfully applied to determine the level of three industrial dyes in different water samples.

  15. New method based on combining ultrasonic assisted miniaturized matrix solid-phase dispersion and homogeneous liquid-liquid extraction for the determination of some organochlorinated pesticides in fish

    Energy Technology Data Exchange (ETDEWEB)

    Rezaei, Farahnaz [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Narmak, Tehran 16846 (Iran, Islamic Republic of); Hosseini, Mohammad-Reza Milani, E-mail: drmilani@iust.ac.ir [Department of Analytical Chemistry, Faculty of Chemistry, Iran University of Science and Technology, Narmak, Tehran 16846 (Iran, Islamic Republic of); Electroanalytical Chemistry Research Center, Iran University of Science and Technology, Narmak, Tehran 16846 (Iran, Islamic Republic of)

    2011-09-30

    Highlights: {yields} Ultrasonic assisted miniaturized matrix solid-phase dispersion combined with HLLE was developed as a new method for the extraction of OCPs in fish. {yields} The goal of this combination was to enhance the selectivity of HLLE procedure and to extend its application in biological samples. {yields} This method proposed the advantages of good detection limits, lower consumption of reagents, and does not need any special instrumentation. - Abstract: In this study, ultrasonic assisted miniaturized matrix solid-phase dispersion (US-MMSPD) combined with homogeneous liquid-liquid extraction (HLLE) has been developed as a new method for the extraction of organochlorinated pesticides (OCPs) in fish prior to gas chromatography with electron capture detector (GC-ECD). In the proposed method, OCPs (heptachlor, aldrin, DDE, DDD, lindane and endrin) were first extracted from fish sample into acetonitrile by US-MMSPD procedure, and the extract was then used as consolute solvent in HLLE process. Optimal condition for US-MMSPD step was as follows: volume of acetonitrile, 1.5 mL; temperature of ultrasound, 40 deg. C; time of ultrasound, 10 min. For HLLE step, optimal results were obtained at the following conditions: volume of chloroform, 35 {mu}L; volume of aqueous phase, 1.5 mL; volume of double distilled water, 0.5 mL; time of centrifuge, 10 min. Under the optimum conditions, the enrichment factors for the studied compounds were obtained in the range of 185-240, and the overall recoveries were ranged from 39.1% to 81.5%. The limits of detection were 0.4-1.2 ng g{sup -1} and the relative standard deviations for 20 ng g{sup -1} of the OCPs, varied from 3.2% to 8% (n = 4). Finally, the proposed method has been successfully applied to the analysis of the OCPs in real fish sample, and satisfactory results were obtained.

  16. Molecular dynamics simulations of hydrophobous ions at the liquid-liquid interfaces: case of dicarbollide anions as synergy agents and of ionic liquids as extracting medium; Simulations par dynamique moleculaire d'ions hydrophobes aux interfaces liquide - liquide: le cas des anions dicarbollides comme agents de synergie et celui des liquides ioniques comme milieu extractant

    Energy Technology Data Exchange (ETDEWEB)

    Chevrot, G

    2008-01-15

    Based on molecular dynamics simulations, we first describe the distribution of dicarbollide salts (CCD{sup -}, Mn{sup +}) in concentrated monophasic solutions (water, chloroform, octanol, nitrobenzene) and in the corresponding biphasic 'oil' - water solutions. We point to the importance of surface activity of the CCD{sup -}s and of their self-aggregation in water, with marked counterions effects, and we explain the synergistic effect of CCD{sup -}s in the Eu{sup 3+} extraction by BTP ligands. In the second part of the thesis we report exploratory simulations on the extraction of Sr{sup 2+} by 18-crown-6 to an hydrophobic ionic liquid ([BMI][PF6]), focusing on the liquid - liquid interface. Analogies and differences with a classical aqueous interface are outlined. (author)

  17. Complex Formation and Liquid-Liquid Extraction in the Niobium(V – 2,4-Dihydroxythiophenol– Hydrophobic Amines System

    Directory of Open Access Journals (Sweden)

    ALI Z. ZALOV

    2015-12-01

    Full Text Available The formation and solvent extraction of new ion-association com¬ple- ¬xes between anionic chelat of niobium(V with 2,4-dihydroxy¬thio¬phenol (DHTP and hydrophobic amines (HAs. The HAs were aniline (An, N-methyl¬aniline (MAn, N,N-dimethylaniline (DAn. The optimum conditions for the extraction of mixed ligand complexes (MLC (organic solvent, extraction time, acidity of the aqueous phase, concentration of reagents, some key constants {association constant (β, extraction constant (Kex} and analytical characteristics were determined. The molar absorptivities of MLC were calculated ε =(3.5-3.9 × 104 L mol–1 cm–1 . The Beer’s law was applicable in the range of 2.2-100 μg/mL.

  18. A calculation model for liquid-liquid extraction of protactinium by 2,6-dimethyl-4-heptanol

    Directory of Open Access Journals (Sweden)

    Knight Andrew W.

    2015-12-01

    Full Text Available Reprocessing of spent nuclear fuel usually employs the solvent extraction technique to recover fissile material, isolate other valuable radionuclides, recover precious metals, and remove contaminants. Efficient recovery of these species from highly radioactive solutions requires a detailed understanding of reaction conditions and metal speciation that leads to their isolation in pure forms. Due to the complex nature of these systems, identification of ideal reaction conditions for the efficient extraction of specific metals can be challenging. Thus, the development of experimental approaches that have the potential to reduce the number of experiments required to identify ideal conditions are desirable. In this study, a full-factorial experimental design was used to identify the main effects and variable interactions of three chemical parameters on the extraction of protactinium (Pa. Specifically we investigated the main effects of the anion concentration (NO3-, Cl- extractant concentration, and solution acidity on the overall extraction of protactinium by 2,6-dimethyl-4-heptanol (diisobutylcarbinol; DIBC from both HCl and HNO3 solutions. Our results indicate that in HCl, the extraction of protactinium was dominated by the solution acidity, while in nitric acid the extraction was strongly effected by the [DIBC]. Based on our results, a mathematical model was derived, that describes the relationship between concentrations of anions, extractant, and solution acidity and the expected values of Pa distribution coefficients in both HCl and HNO3. This study demonstrates the potential to predict the distribution coefficient values, based upon a mathematical model generated by a full-factorial experimental design.

  19. A modified approach for isolation of essential oil from fruit of Amorpha fruticosa Linn using microwave-assisted hydrodistillation concatenated liquid-liquid extraction.

    Science.gov (United States)

    Chen, Fengli; Jia, Jia; Zhang, Qiang; Gu, Huiyan; Yang, Lei

    2017-11-17

    In this work, a modified technique was developed to separate essential oil from the fruit of Amorpha fruticosa using microwave-assisted hydrodistillation concatenated liquid-liquid extraction (MHD-LLE). The new apparatus consists of two series-wound separation columns for separating essential oil, one is the conventional oil-water separation column, and the other is the extraction column of components from hydrosol using an organic solvent. Therefore, the apparatus can simultaneously collect the essential oil separated on the top of hydrosol and the components extracted from hydrosol using an organic solvent. Based on the yield of essential oil in the first and second separation columns, the effects of parameters were investigated by single factor experiments and Box-Behnken design. Under the optimum conditions (2mL ethyl ether as the extraction solvent in the second separation column, 12mL/g liquid-solid ratio, 4.0min homogenate time, 35min microwave irradiation time and 540W microwave irradiation power), satisfactory yields for the essential oil in the first separation column (10.31±0.33g/kg) and second separation column (0.82±0.03g/kg) were obtained. Compared with traditional methods, the developed method gave a higher yield of essential oil in a shorter time. In addition, GC-MS analysis of the essential oil indicated significant differences of the relative contents of individual volatile components in the essential oils obtained in the two separation columns. Therefore, the MHD-LLE technique developed here is a good alternative for the isolation of essential oil from A. fruticosa fruit as well as other herbs. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Removal of chromium(III) from aqueous waste solution by liquid-liquid extraction in a circular microchannel.

    Science.gov (United States)

    Luo, Jian Hong; Li, Jun; Guo, Lei; Zhu, Xin Hua; Dai, Shuang; Li, Xing

    2017-11-01

    A new circular microchannel device has been proposed for the removal of chromium(III) from aqueous waste solution by using kerosene as a diluent and (2-ethylhexyl) 2-ethylhexyl phosphonate as an extractant. The proposed device has several advantages such as a flexible and easily adaptable design, easy maintenance, and cheap setup without the requirement of microfabrication. To study the extraction efficiency and advantages of the circular microchannel device in the removal of chromium(III), the effects of various operating conditions such as the inner diameter of the channel, the total flow velocity, the phase ratio, the initial pH of aqueous waste solution, the reaction temperature and the initial concentration of extractant on the extraction efficiency are investigated and the optimal process conditions are obtained. The results show that chromium(III) in aqueous waste solution can be effectively removed with (2-ethylhexyl) 2-ethylhexyl phosphonate in the circular microchannel. Under optimized conditions, an extraction efficiency of chromium(III) of more than 99% can be attained and the aqueous waste solution can be discharged directly, which can meet the Chinese national emission standards.

  1. Acetic acid recovery from fast pyrolysis oil. An exploratory study on liquid-liquid reactive extraction using aliphatic tertiary amines

    NARCIS (Netherlands)

    Mahfud, F. H.; van Geel, F. P.; Venderbosch, R. H.; Heeres, H. J.

    2008-01-01

    Flash pyrolysis oil or Bio-oil (BO), obtained by flash pyrolysis of lignocellulosic biomass, is very acidic in nature. The major component responsible for this acidity is acetic acid, present in levels up to 2-10 wt%. Here, we report an exploratory study on BO upgrading by reactive extraction of

  2. COSMO-RS assisted solvent screening for liquid-liquid extraction of mono ethylene glycol from aqueous streams

    NARCIS (Netherlands)

    Garcia Chavez, L.Y.; Hermans, A.J.; Schuur, Boelo; de Haan, A.B.

    2012-01-01

    Separation of polar mixtures from water is one of the most energy consuming operations in industry, because of the high heat of vaporization of water. Avoiding evaporation of water by applying liquid–liquid extraction instead of (multi-effect) evaporation can yield large energy-savings. The

  3. Determination of Fusarium toxins in functional vegetable milks applying salting-out-assisted liquid-liquid extraction combined with ultra-high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Hamed, Ahmed M; Arroyo-Manzanares, Natalia; García-Campaña, Ana M; Gámiz-Gracia, Laura

    2017-11-01

    Vegetable milks are considered as functional foods due to their physiological benefits. Although the consumption of these products has significantly increased, they have received little attention in legislation with regard to contaminants. However, they may contain mycotoxins resulting from the use of contaminated raw materials. In this work, ultra-high-performance liquid chromatography tandem mass spectrometry has been proposed for the determination of the most relevant Fusarium toxins (fumonisin B1 and B2, HT-2 and T-2 toxins, zearalenone, deoxynivalenol and fusarenon-X) in different functional beverages based on cereals, legumes and seeds. Sample treatment consisted of a simple salting-out-assisted liquid-liquid extraction with no further clean-up. The method provided limits of quantification between 3.2 and 57.7 µg L-1, recoveries above 80% and precision with RSD lower than 12%. The method was also applied for studying the occurrence of these mycotoxins in market samples of vegetable functional beverages and deoxynivalenol was found in three oat-based commercial drinks.

  4. Determination of thiophanate-methyl and its metabolites at trace level in spiked natural water using the supported liquid membrane extraction and the microporous membrane liquid-liquid extraction techniques combined on-line with high-performance liquid chromatography.

    Science.gov (United States)

    Sandahl, M; Mathiasson, L; Jönsson, J A

    2000-09-29

    On-line supported liquid membrane (SLM) extraction and microporous membrane liquid-liquid extraction (MMLLE) techniques for sample preparation of natural water samples have been developed for the determination of thiophanate-methyl (TM), carbendazim (MBC) and 2-aminobenzimidazole (2-AB) using reversed-phase HPLC. The combination of SLM extraction and MMLLE offers extraction conditions that makes it possible to determine a wide variety of compounds, i.e., permanently charged, ionisable and non-polar at sub ppb level. The detection limits obtained after extraction are about 0.1 microg/l for MBC and 2-AB using SLM, and 0.5 x Lg/l for TM using MMLLE and the precision is better than 5% for both systems. Typical enrichment rates are 0.6 and 2.7 times/min using SLM and MMLLE, respectively.

  5. A new tunable dispersive liquid-liquid micro extraction method developed for the simultaneous preconcentration of lead and cadmium from lakes water: a multivariate study

    Science.gov (United States)

    Bilal, Muhammad; Kazi, Tasneem Gul; Afridi, Hassan Imran; Ali, Jamshed; Baig, Jameel Ahmed; Arain, Mohammad Balal; Khan, Mustafa

    2017-08-01

    A green tunable dispersive liquid-liquid micro extraction (TDLLME) technique was established for the simultaneous enrichment of lead (Pb) and cadmium (Cd) from different lakes water before analysis by flame atomic absorption spectrometry (FAAS). A solvent known as tunable polarity solvent (TPS), mixture of 1,8-diazabicyclo-[5.4.0]-undec-7-ene (DBU) and 1-decanol, has been employed as extractant in aqueous medium. In first step this mixture can be made polar by slowly bubbling the antisolvent trigger (CO2) through the solution, which makes a monophasic solution. During this step hydrophobic complexes of the metals with 8-hydroxy quinoline (8-HQ) were extracted by TPS. Then the mixture was switched back to hydrophobic one by heating and/or bubbling nitrogen, turning the mixture into two phases again. In second phase the metals were leached out from the complexes entrapped in TPS, by treating with a solution of nitric acid and exposing the mixture to CO2, which switched the mixture into single phase. Then N2 purging and/or heating again turned the mixture into two phases. The acidic aqueous phase containing the metals was introduced to FAAS for analysis, whereas TPS was recycled for next experiment. Different parameters, affecting the efficiency the technique, were optimized by multivariate approach. The method was applied to certified reference material of water and to a real sample spiked with standards of known concentration, to confirm its validity and accuracy. LOD obtained for Pb and Cd were 0.560 and 0.056 μg L- 1 respectively. The developed method was applied successfully to the real water samples of two lakes of Sindh, Pakistan.

  6. Salting-out homogeneous liquid-liquid extraction approach applied in sample pre-processing for the quantitative determination of entecavir in human plasma by LC-MS.

    Science.gov (United States)

    Zhao, Feng-Juan; Tang, Hong; Zhang, Qing-Hua; Yang, Jin; Davey, Andrew K; Wang, Ji-Ping

    2012-01-15

    A convenient, robust, economical and selective sample preparation method for the quantitative determination of entecavir in human plasma by LC-MS was developed and validated. Entecavir and the internal standard of acyclovir were extracted from 500 μL of human plasma by a salting-out homogeneous liquid-liquid extraction approach (SHLLE) with acetonitrile as the organic extractant and magnesium sulfate as the salting-out reagent. They were analyzed on a Hanbon® Lichrospher RP C18 HPLC column (150 mm×2.0 mm; 5 μm) with gradient elution. The mobile phase comprised 0.1% acetic acid-0.2 mmol ammonium acetate in water (mobile phase A) and acetonitrile (mobile phase B). The flow rate is 0.2 mL/min. The analytes were detected by a LC-MS 2010 single quadrupole mass spectrometer instrument equipped with an electrospray ionization interface using selective ion monitoring positive mode. A "post cut" column switch technique was incorporated into the method to remove interferences of earlier and later eluting matrix components than entecavir and internal standard, including salting-out reagent used in sample pre-processing. The method was validated over the concentration range of 0.05-20 ng/mL. The intra-day and inter-day precision of the assay, as measured by the coefficient of variation (%CV), was within 3.59%, and the intra-day assay accuracy was found to be within 4.88%. The average recovery of entecavir was about 50% and the ion suppression was approximately 44% over the standard curve. Comparison of matrix effect between SHLLE and SPE by continuous post column infusion showed that these two methods got similar, slight ion suppression. The SHLLE method has been successfully utilized for the analysis of entecavir in post-dose samples from a clinical study. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  7. Recycling of indium from CIGS photovoltaic cells: potential of combining acid-resistant nanofiltration with liquid-liquid extraction.

    Science.gov (United States)

    Zimmermann, Yannick-Serge; Niewersch, Claudia; Lenz, Markus; Kül, Zöhre Zohra; Corvini, Philippe F-X; Schäffer, Andreas; Wintgens, Thomas

    2014-11-18

    Electronic consumer products such as smartphones, TV, computers, light-emitting diodes, and photovoltaic cells crucially depend on metals and metalloids. So-called "urban mining" considers them as secondary resources since they may contain precious elements at concentrations many times higher than their primary ores. Indium is of foremost interest being widely used, expensive, scarce and prone to supply risk. This study first investigated the capability of different nanofiltration membranes of extracting indium from copper-indium-gallium- selenide photovoltaic cell (CIGS) leachates under low pH conditions and low transmembrane pressure differences (98% by nanofiltration, separating it from parts of the Ag, Sb, Se, and Zn present. LLE using di-(2-ethylhexyl)phosphoric acid (D2EHPA) extracted 97% of the indium from the retentates, separating it from all other elements except for Mo, Al, and Sn. Overall, 95% (2.4 g m(-2) CIGS) of the indium could be extracted to the D2EHPA phase. Simultaneously, by nanofiltration the consumption of D2EHPA was reduced by >60% due to the metal concentration in the reduced retentate volume. These results show clearly the potential for efficient scarce metal recovery from secondary resources. Furthermore, since nanofiltration was applicable at very low pH (≥ 0.6), it may be applied in hydrometallurgy typically using acidic conditions.

  8. Quantitative Analysis of Volatile Impurities in Diallyldimethylammonium Chloride Monomer Solution by Gas Chromatography Coupled with Liquid-Liquid Extraction

    Directory of Open Access Journals (Sweden)

    Cheng Liu

    2017-01-01

    Full Text Available The quantitative analysis method for volatile impurities in diallyldimethylammonium chloride (DADMAC monomer solution was established in this paper. The volatile impurities were quantitatively analyzed with trichloromethane as extraction solvent and n-hexane as internal standard by using gas chromatography (GC coupled with solvent extraction, and the chromatographic conditions, quantitative methods, and extraction conditions were systematically investigated in detail. The results showed that excellent linear relationships of 5 volatile impurities (dimethylamine, allyldimethylamine, allyl chloride, allyl alcohol, and allyl aldehyde were obtained in the range of 1–100 mg·L−1. The method also showed good specificity, recovery (95.0%–107.5%, and relative standard deviation (RSD, 1.40%–7.67%. This method could accurately detect the whole volatile impurities in DADMAC monomer solution quantitatively in one time with a low detection limit. Furthermore, this method is conducive to the preparation of highly pure DADMAC monomer and the development of national and international standards of the DADMAC monomer product quality, and the results could provide a strong foundation for the regulation and mechanism research of impurities on monomer reactivity in polymerization.

  9. Comparison between different liquid-liquid and solid phase methods of extraction prior to the identification of the phenolic fraction present in olive oil washing wastewater from the two-phase olive oil extraction system

    Directory of Open Access Journals (Sweden)

    S. Jiménez-Herrera

    2017-09-01

    Full Text Available Phenolic compounds from olive mill wastewater (OMW, are characterized by a strong antioxidant activity. At the same time, they represent an environmental problem because they are difficult to degrade. The purpose of this work was to identify these biologically active compounds in the OMW from two-phase olive oil production in order to convert a polluting residue into a source of natural antioxidants. After optimizing the extraction process of phenolic compounds using liquid-liquid extraction (LLE and solid phase extraction (SPE methods, it was determined that the most appropriate sequence comprised a previous centrifugation to remove the lipid fraction, followed by liquid extraction with ethyl acetate or SPE. The most important compounds identified in olive oil washing wastewater (OOWW were tyrosol, hydroxytyrosol and succinic acid; whereas the ones in the wastewater derived from the washing of the olives (OWW were cresol, catechol, 4-methylcatechol, hydrocinnamic acid and p-hydroxy-hydrocinnamic acid.

  10. High-throughput salting-out assisted liquid/liquid extraction with acetonitrile for the simultaneous determination of simvastatin and simvastatin acid in human plasma with liquid chromatography.

    Science.gov (United States)

    Zhang, Jun; Rodila, Ramona; Gage, Eric; Hautman, Mathew; Fan, Leimin; King, Linda L; Wu, Huaiqin; El-Shourbagy, Tawakol A

    2010-02-28

    Simvastatin (SS) is an effective cholesterol-lowering medicine, and is hydrolyzed to simvastatin acid (SSA) after oral administration. Due to SS and SSA inter-conversion and its pH and temperature dependence, SS and SSA quantitation is analytically challenging. Here we report a high-throughput salting-out assisted liquid/liquid extraction (SALLE) method with acetonitrile and mass spectrometry compatible salts for simultaneous LC-MS/MS analysis of SS and SSA. The sample preparation of a 96-well plate using SALLE was completed within 20 min, and the SALLE extract was diluted and injected into an LC-MS/MS system with a cycle time of 2.0 min/sample. The seamless interface of SALLE and LC-MS eliminated drying down step and thus potential sample exposure to room or higher temperature. The stability of SS and SSA in various concentration ratios in plasma was evaluated at room and low (4 degrees C) temperature and the low temperature (4 degrees C) was found necessary to maintain sample integrity. The short sample preparation time along with controlled temperature (2-4 degrees C) and acidity (pH 4.5) throughout sample preparation minimized the conversion of SS-->SSA to SS to 0.00% The method was validated with a lower limit of quantitation (LLOQ) of 0.094 ng mL(-1) for both SS and SSA and a sample volume of 100 microL. The method was used for a bioequivalence study with 4048 samples. Incurred sample reproducibility (ISR) analysis of 362 samples from the study exceeded ISR requirement with 99% re-analysis results within 100+/-20% of the original analysis results. Copyright 2010 Elsevier B.V. All rights reserved.

  11. Method development for the quantitation of ABT-578 in rabbit artery tissue by 96-well liquid-liquid extraction and liquid chromatography/tandem mass spectrometric detection.

    Science.gov (United States)

    Ji, Qin C; Zhang, Jun; Rodila, Ramona; Watson, Pamela; El-Shourbagy, Tawakol

    2004-01-01

    Quantitative determination of drug concentrations in tissue samples can provide critical information for drug metabolism, kinetics, and toxicity evaluations. For analysis of tissue samples using liquid chromatography/tandem mass spectrometric (LC/MS/MS) detection, homogenization is a critical step in achieving good assay performance. Assay performance can be closely evaluated by spiking the drug directly into tissue samples prior to homogenization. It is especially important to include this assay evaluation for the analysis of artery tissue samples because artery tissue is very elastic, making it quite a challenge to develop an effective procedure for homogenization. An LC/MS/MS assay in 96-well format using liquid-liquid extraction was developed for analyzing ABT-578 in rabbit artery samples. Tissue quality control samples were prepared by spiking ABT-578 stock solutions directly into the tissue before homogenization. The usage of the tissue control samples gives a thorough evaluation of the sample preparation process that includes both homogenization and sample extraction. A 20% blood in saline solution was used as a homogenization solution. Calibration standards were made by spiking ABT-578 into rabbit whole blood. Blood quality control samples were also prepared by spiking ABT-578 into rabbit whole blood. These blood QC samples were used to confirm the validity of the calibration curve. A lower limit of quantitation of 0.050 ng/mL was achieved. The linear dynamic range of blood standards was from 0.050-30.3 ng/mL with the correlation coefficient (r) ranging from 0.9969-0.9996. Overall %CV was between 1.3 and 7.0%, and analytical recovery was between 98.2 and 105.8% for blood QC samples. The %CVs for tissue QC samples were between 6.7 and 13.0%, and analytical recovery after correction was between 93.5 and 114.3%. Copyright 2004 John Wiley & Sons, Ltd.

  12. An integrated process for the recovery of high added-value compounds from olive oil using solid support free liquid-liquid extraction and chromatography techniques.

    Science.gov (United States)

    Angelis, Apostolis; Hamzaoui, Mahmoud; Aligiannis, Nektarios; Nikou, Theodora; Michailidis, Dimitris; Gerolimatos, Panagiotis; Termentzi, Aikaterini; Hubert, Jane; Halabalaki, Maria; Renault, Jean-Hugues; Skaltsounis, Alexios-Léandros

    2017-03-31

    An integrated extraction and purification process for the direct recovery of high added value compounds from extra virgin olive oil (EVOO) is proposed by using solid support free liquid-liquid extraction and chromatography techniques. Two different extraction methods were developed on a laboratory-scale Centrifugal Partition Extractor (CPE): a sequential strategy consisting of several "extraction-recovery" cycles and a continuous strategy based on stationary phase co-current elution. In both cases, EVOO was used as mobile phase diluted in food grade n-hexane (feed mobile phase) and the required biphasic system was obtained by adding ethanol and water as polar solvents. For the sequential process, 17.5L of feed EVOO containing organic phase (i.e. 7L of EVOO treated) were extracted yielding 9.5g of total phenolic fraction corresponding to a productivity of 5.8g/h/L of CPE column. Regarding the second approach, the co-current process, 2L of the feed oil phase (containing to 0.8L of EVOO) were treated at 100mL/min yielding 1.03g of total phenolic fraction corresponding to a productivity of 8.9g/h/L of CPE column. The total phenolic fraction was then fractionated by using stepwise gradient elution Centrifugal Partition Chromatography (CPC). The biphasic solvent systems were composed of n-hexane, ethyl acetate, ethanol and water in different proportions (X/Y/2/3, v/v). In a single run of 4h on a column with a capacity of 1L, 910mg of oleocanthal, 882mg of oleacein, 104mg of hydroxytyrosol were successfully recovered from 5g of phenolic extract with purities of 85%, 92% and 90%, respectively. CPC fractions were then submitted to orthogonal chromatographic steps (adsorption on silica gel or size exclusion chromatography) leading to the isolation of additional eleven compounds belonging to triterpens, phenolic compounds and secoiridoids. Among them, elenolic acid ethylester was found to be new compound. Thin Layer Chromatography (TLC), Nuclear magnetic Resonance (NMR) and

  13. Liquid-liquid extraction of uranyl by TBP: the TBP and ions models and related interfacial features revisited by MD and PMF simulations.

    Science.gov (United States)

    Benay, G; Wipff, G

    2014-03-20

    We report a molecular dynamics (MD) study of biphasic systems involved in the liquid-liquid extraction of uranyl nitrate by tri-n-butylphosphate (TBP) to hexane, from "pH neutral" or acidic (3 M nitric acid) aqueous solutions, to assess the model dependence of the surface activity and partitioning of TBP alone, of its UO2(NO3)2(TBP)2 complex, and of UO2(NO3)2 or UO2(2+) uncomplexed. For this purpose, we first compare several electrostatic representations of TBP with regards to its polarity and conformational properties, its interactions with H2O, HNO3, and UO2(NO3)2 species, its relative free energies of solvation in water or oil environments, the properties of the pure TBP liquid and of the pure-TBP/water interface. The free energies of transfer of TBP, UO2(NO3)2, UO2(2+), and the UO2(NO3)2(TBP)2 complex across the water/oil interface are then investigated by potential of mean force (PMF) calculations, comparing different TBP models and two charge models of uranyl nitrate. Describing uranyl and nitrate ions with integer charges (+2 and -1, respectively) is shown to exaggerate the hydrophilicity and surface activity of the UO2(NO3)2(TBP)2 complex. With more appropriate ESP charges, mimicking charge transfer and polarization effects in the UO2(NO3)2 moiety or in the whole complex, the latter is no more surface active. This feature is confirmed by MD, PMF, and mixing-demixing simulations with or without polarization. Furthermore, with ESP charges, pulling the UO2(NO3)2 species to the TBP phase affords the formation of UO2(NO3)2(TBP)2 at the interface, followed by its energetically favorable extraction. The neutral complexes should therefore not accumulate at the interface during the extraction process, but diffuse to the oil phase. A similar feature is found for an UO2(NO3)2(Amide)2 neutral complex with fatty amide extracting ligands, calling for further simulations and experimental studies (e.g., time evolution of the nonlinear spectroscopic signature and of surface

  14. Simultaneous determination of 14 sulfonamides and tetracyclines in biogas plants by liquid-liquid-extraction and liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Spielmeyer, Astrid; Ahlborn, Jenny; Hamscher, Gerd

    2014-04-01

    A new method for the analysis of sulfonamides and tetracyclines in heterogenic biogas plant input samples and fermentation residues is introduced. Veterinary antibiotics are only partially absorbed in the animal gut; therefore, animal manure can contain high loads of these substances. Animal manure is used for biogas generation, so antibiotics can enter the anaerobic fermentation process this way. However, only little is known about the fate of antibiotics within this process, also due to the lack of suitable analytical methods for this complex sample matrix. Therefore, we developed a method for the analysis of ten sulfonamides (sulfachloropyridazine, sulfadiazine, sulfadimethoxine, sulfaguanidine, sulfamerazine, sulfamethazine, sulfamethoxazol, sulfamethoxypyridazin, sulfapyridine, sulfathiazole) and four tetracyclines (chlortetracycline, doxycycline, oxytetracycline, tetracycline) in biogas plant input and output samples, including a single liquid-liquid-extraction step and analysis via liquid chromatography (LC) and triple quadrupole mass spectrometry. The detection limit of this method ranges from 0.01 to 0.08 mg kg(-1). Matrix calibration using antibiotic-free cattle feces and isotopic-labeled internal standards enables quantification of antibiotics in different matrices such as animal manure, dung, or fermenter outputs with recovery rates between 70 and 130 %. This makes the method suitable for investigating the fate of antibiotics in animal manure and fermentation processes. A screening of 15 German biogas plants revealed the presence of several antibiotics up to 9 mg kg(-1) (201 mg kg(-1) dry matter). During the fermentation process, elimination occurs; however, with the exception of chlortetracycline, the antibiotic content remains in the same order of magnitude.

  15. Salting-out-assisted liquid-liquid extraction as a suitable approach for determination of methoxetamine in large sets of tissue samples.

    Science.gov (United States)

    Hajkova, Katerina; Jurasek, Bronislav; Sykora, David; Palenicek, Tomas; Miksatkova, Petra; Kuchar, Martin

    2016-02-01

    A new designer drug, a dissociative anesthetic, and a putative N-methyl-D-aspartate receptor antagonist, methoxetamine (MXE) noted by the EU Early Warning System has been already identified as a cause of several fatalities worldwide. The primary objective of this work was to develop a suitable sample preparation method allowing for isolation of MXE and its main metabolites in high yields from rat brain, liver, and lungs. For the purpose of the project, MXE and five metabolites were synthesized in-house, specifically O-desmethyl-normethoxetamine, O-desmethylmethoxetamine, dihydro-O-desmethylmethoxetamine, normethoxetamine, and dihydromethoxetamine. A sample preparation procedure consisted in the homogenization of the tissue applying salting-out-assisted liquid-liquid extraction (SALLE). A subsequent liquid chromatography-mass spectrometry (LC-MS) analysis was based on reversed-phased chromatography hyphenated with a triple quad MS system in a positive electrospray mode. Multiple reaction monitoring (MRM) was used for qualification and quantification of the analytes. The quantification was based on the application of an isotopically labeled internal standard, normethoxetamine-d3. The matrix-matched calibrations were prepared for each type of matrix with regression coefficients 0.9943-1.0000. The calibration curves were linear in the concentration range of 2.5-250 ng g(-1). Limits of quantification (LOQs) were estimated as 2.5 and 5 ng g(-1), respectively. Recovery (80-117%) and matrix effect (94-110%) at 100 ng g(-1) and intra- and inter-day accuracy and precision at low (2.5 ng g(-1)), middle (25 ng g(-1)), and upper (250 ng g(-1)) concentration levels for all the analytes in all three types of tissues were also determined. The developed analytical method was applied to a set of real samples gathered in toxicological trials on rats and MXE, and its metabolites were determined successfully.

  16. Combined dispersive solid-phase extraction-dispersive liquid-liquid microextraction-derivatization for gas chromatography-mass spectrometric determination of aliphatic amines on atmospheric fine particles.

    Science.gov (United States)

    Majedi, Seyed Mohammad; Lee, Hian Kee

    2017-02-24

    Short-chain aliphatic amines are ubiquitous in the atmospheric environment. They play an important role in the formation and growth of atmospheric particles. As such, there is a pressing need to monitor these particle-bound compounds present at trace quantities. The present work describes an efficient, one-step microextraction technique for the preconcentration and detection of trace levels of 10 aliphatic amines on fine particles (particulate matter of 2.5μm or less (PM2.5)) in the atmosphere. After extraction of amines from particles in acidified water samples, carbon-based sorbents (in dispersive solid-phase extraction mode), and vortex agitation were utilized for simultaneous derivatization-extraction and dispersive liquid-liquid microextraction. The approach significantly increased the recoveries and enrichment of the amine derivatives. This one-step, combined technique is proposed for the first time. Several influential factors including type and concentration of derivatization reagent (for gas chromatographic separation), type of buffer, sample pH, types and volumes of extraction and disperser solvents, type and amount of sorbent, vortex time and temperature, desorption solvent type and volume, and salt content were investigated and optimized. Under the optimum conditions, high enrichment factors (in the range of between 307 and 382) and good reproducibility (relative standard deviations, below 7.0%, n=5) were achieved. The linearity ranged from 0.1μg/L-100μg/L, and from 0.5μg/L-100μg/L, depending on the analytes. The limits of detection were between 0.02μg/L (corresponding to ∼0.01ng/m(3) in air) and 0.09μg/L (corresponding to ∼0.04ng/m(3) in air). The developed method was successfully applied to the analysis of PM2.5 samples collected by air sampling through polytetrafluoroethylene filters. The concentration levels of amines ranged from 1.04 to 4.16ng/m(3) in the air sampled. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Salting-out assisted liquid-liquid extraction with the aid of experimental design for determination of benzimidazole fungicides in high salinity samples by high-performance liquid chromatography.

    Science.gov (United States)

    Wen, Yingying; Li, Jinhua; Yang, Fangfang; Zhang, Weiwei; Li, Weiran; Liao, Chunyang; Chen, Lingxin

    2013-03-15

    A novel method for the simultaneous separation and determination of four benzimidazole fungicides (i.e., carbendazim, fuberidazole, thiophanate-methyl and thiophanate) in high salinity samples was developed by using salting-out assisted liquid-liquid extraction (SALLE) via water-miscible acetonitrile as the extractant coupled with high-performance liquid chromatography. Box-Behnken design and response surface were employed to assist the optimization of SALLE conditions, including volume of salting-out solvent, the pH of sample solution and salting-out solvent as variable factors. The optimal salting-out parameters were obtained as follows: 2 mL of acetonitrile was added to 2 mL of sample solution with pH=4 and then 2 mL salting-out solvent containing 5 mol L(-1) sodium chloride at a pH of 7 was added to the solution for extraction. This procedure afforded a convenient and cost-saving operation with good cleanup ability for the benzimidazole fungicides, such as good linear relationships (R>0.996) between peak area and concentration from 2.5 ng mL(-1) to 500 ng mL(-1), low limits of detection between 0.14 ng mL(-1) and 0.38 ng mL(-1) and the intra-day precisions of retention time below 1.0%. The method recoveries obtained at fortified three concentrations for three seawater samples ranged from 60.4% to 99.1%. The simple, rapid and eco-benign SALLE based method proved potentially applicable for trace benzimidazole fungicides analysis in high salinity samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Speciation of As(III) and As(V) in water samples by graphite furnace atomic absorption spectrometry after solid phase extraction combined with dispersive liquid-liquid microextraction based on the solidification of floating organic drop.

    Science.gov (United States)

    Shamsipur, Mojtaba; Fattahi, Nazir; Assadi, Yaghoub; Sadeghi, Marzieh; Sharafi, Kiomars

    2014-12-01

    A solid phase extraction (SPE) coupled with dispersive liquid-liquid microextraction based on the solidification of floating organic drop (DLLME-SFO) method, using diethyldithiphosphate (DDTP) as a proper chelating agent, has been developed as an ultra preconcentration technique for the determination of inorganic arsenic in water samples prior to graphite furnace atomic absorption spectrometry (GFAAS). Variables affecting the performance of both steps were thoroughly investigated. Under optimized conditions, 100mL of As(ΙΙΙ) solution was first concentrated using a solid phase sorbent. The extract was collected in 2.0 mL of acetone and 60.0 µL of 1-undecanol was added into the collecting solvent. The mixture was then injected rapidly into 5.0 mL of pure water for further DLLME-SFO. Total inorganic As(III, V) was extracted similarly after reduction of As(V) to As(III) with potassium iodide and sodium thiosulfate and As(V) concentration was calculated by difference. A mixture of Pd(NO3)2 and Mg(NO3)2 was used as a chemical modifier in GFAAS. The analytical characteristics of the method were determined. The calibration graph was linear in the rage of 10-100 ng L(-1) with detection limit of 2.5 ng L(-1). Repeatability (intra-day) and reproducibility (inter-day) of method based on seven replicate measurements of 80 ng L(-1) of As(ΙΙΙ) were 6.8% and 7.5%, respectively. The method was successfully applied to speciation of As(III), As(V) and determination of the total amount of As in water samples and in a certified reference material (NIST RSM 1643e). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Vortex-assisted liquid-liquid-liquid microextraction (VALLLME) technique: A new microextraction approach for direct liquid chromatography and capillary electrophoresis analysis.

    Science.gov (United States)

    Makahleh, Ahmad; Yap, Hui Fang; Saad, Bahruddin

    2015-10-01

    A new, rapid and sensitive microextraction technique named vortex-assisted liquid-liquid-liquid microextraction (VALLLME) is proposed. The complete extraction process involves two steps. First, a vortex-assisted liquid-liquid microextraction (VALLME) procedure was used to extract the analytes from a relatively large volume of sample (donor phase) to a small volume of organic solvent (intermediate phase). Next, a micro-vortex-assisted liquid-liquid extraction (µ-VALLE) was used to extract the target analytes from the intermediate phase to a smaller volume of aqueous solution (acceptor phase). The final extract (acceptor phase) can be directly injected into the high performance liquid chromatography or capillary electrophoresis units without any further treatments. The selection of the intermediate phase and the manipulation of pH are key parameters that ensure good extraction efficiency of the technique. The proposed technique has been successfully applied for the determination of carvedilol (used as model analyte) in biological fluid samples. The optimum extraction conditions were: toluene as intermediate phase (150 μL); pH of the donor phase, 9.5; vortex time of the VALLME, 45 s (maximum speed, 2500 rpm); 0.1M HCl (15 μL) as acceptor phase; vortexing time of the µ-VALLME, 75 s (maximum stirring speed, 2500 rpm) and salt concentration in the donor phase, 5% (w/v). Under these conditions, enrichment factors of 51- and 418-fold for VALLME step and VALLLME procedure, respectively, were achieved. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Comparison of two extraction techniques, solid-phase microextraction versus continuous liquid-liquid extraction/solvent-assisted flavor evaporation, for the analysis of flavor compounds in gueuze lambic beer.

    Science.gov (United States)

    Thompson-Witrick, Katherine A; Rouseff, Russell L; Cadawallader, Keith R; Duncan, Susan E; Eigel, William N; Tanko, James M; O'Keefe, Sean F

    2015-03-01

    Lambic is a beer style that undergoes spontaneous fermentation and is traditionally produced in the Payottenland region of Belgium, a valley on the Senne River west of Brussels. This region appears to have the perfect combination of airborne microorganisms required for lambic's spontaneous fermentation. Gueuze lambic is a substyle of lambic that is made by mixing young (approximately 1 year) and old (approximately 2 to 3 years) lambics with subsequent bottle conditioning. We compared 2 extraction techniques, solid-phase microextraction (SPME) and continuous liquid-liquid extraction/solvent-assisted flavor evaporation (CCLE/SAFE), for the isolation of volatile compounds in commercially produced gueuze lambic beer. Fifty-four volatile compounds were identified and could be divided into acids (14), alcohols (12), aldehydes (3), esters (20), phenols (3), and miscellaneous (2). SPME extracted a total of 40 volatile compounds, whereas CLLE/SAFE extracted 36 volatile compounds. CLLE/SAFE extracted a greater number of acids than SPME, whereas SPME was able to isolate a greater number of esters. Neither extraction technique proved to be clearly superior and both extraction methods can be utilized for the isolation of volatile compounds found in gueuze lambic beer. © 2015 Institute of Food Technologists®

  1. Combination of solid phase extraction and dispersive liquid-liquid microextraction for separation/preconcentration of ultra trace amounts of uranium prior to its fiber optic-linear array spectrophotometry determination.

    Science.gov (United States)

    Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji; Shakerian, Farid; Shiralian Esfahani, Golnaz

    2013-12-15

    A simple and sensitive method for the separation and preconcentration of the ultra trace amounts of uranium and its determination by spectrophotometry was developed. The method is based on the combination of solid phase extraction and dispersive liquid-liquid microextraction. Thus, by passing the sample through the basic alumina column, the uranyl ion and some cations are separated from the sample matrix. The retained uranyl ion along with the cations are eluted with 5 mL of nitric acid (2 mol L(-1)) and after neutralization of the eluent, the extracted uranyl ion is converted to its anionic benzoate complex and is separated from other cations by extraction of its ion pair with malachite green into small volume of chloroform using dispersive liquid-liquid microextraction. The amount of uranium is then determined by the absorption measurement of the extracted ion pair at 621 nm using flow injection spectrophotometry. Under the optimum conditions, with 500 mL of the sample, a preconcentration factor of 1980, a detection limit of 40 ng L(-1), and a relative standard deviation of 4.1% (n=6) at 400 ng L(-1) were obtained. The method was successfully applied to the determination of uranium in mineral water, river water, well water, spring water and sea water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A novel approach for an automated liquid/liquid extraction system--principle and application for the determination of several trace contaminants in highly alloyed steels and base alloys.

    Science.gov (United States)

    Wiltsche, Helmar; Prattes, Karl; Knapp, Günter

    2011-06-01

    A novel automated liquid/liquid extraction system was developed for the determination of trace contaminants in unalloyed, alloyed and highly alloyed steels and super alloys. In the presented batch extraction system the aqueous phase and the non-water miscible organic phase were brought into close phase contact by high-speed stirring with a magnetic stir bar. Iodide complexes of Ag, Bi, Cd, Pb, Sb, Sn, Tl, and Zn were extracted from aqueous steel digests into 4-methylpentan-2-one (MIBK) containing 20 g L(-1) trioctylphosphine oxide. Ag, Bi, Cd, Pb, and Tl were extracted quantitatively whereas the extraction yields of Sb, Sn, and Zn were 83%, 61% and 75% respectively. Using high resolution continuum source flame AAS (HR-CS-FAAS) for analyte quantification the method was validated using 21 certified steel reference materials (CRMs).

  3. β-Cyclodextrin enhanced on-line organic solvent field-amplified sample stacking in capillary zone electrophoresis for analysis of ambroxol in human plasma, following liquid-liquid extraction in the 96-well format.

    Science.gov (United States)

    Li, Ji; Bi, Youwei; Wang, Li; Sun, Fanlu; Chen, Zhao; Xu, Guili; Fan, Guorong

    2012-07-01

    A field-amplified sample stacking (FASS) and capillary zone electrophoresis (CZE) method is described for the quantification of ambroxol hydrochloride in human plasma, following liquid-liquid extraction in the 96-well format. The separation was carried out at 25 °C in a 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 15 kV. The background electrolyte (BGE) was composed of 6.25 mM borate-25 mM phosphate (pH 3.0) and 1mM β-cyclodextrin. The detection wavelength was 210 nm. Clean-up and preconcentration of plasma biosamples were developed by 96-well format liquid-liquid extraction (LLE). In this study, FASS in combination with β-cyclodextrin enhanced the sensitivity about 60-70 fold in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision, extraction recovery and robustness. The calibration graph was linear for ambroxol hydrochloride from 2 to 500 ng/ml. The lower limit of quantification was 2 ng/ml. The intra- and inter-day precisions of lowest limit of quantification (LLOQ) were 9.61 and 11.80%, respectively. The method developed was successfully applied to the evaluation of clinical pharmacokinetic study of ambroxol hydrochloride tablet after oral administration to 12 healthy volunteers. Copyright © 2012. Published by Elsevier B.V.

  4. CATION-EXCHANGE SOLID-PHASE AND LIQUID-LIQUID ...

    African Journals Online (AJOL)

    B. S. Chandravanshi

    indicating a purer extract. KEY WORDS: Khat alkaloids, Solid phase extraction, Liquid-liquid extraction, HPLC, Genevac. INTRODUCTION. Khat (Catha edulis Vahl. Endl.) is an evergreen shrub or tree belonging to the Celastraceae family. Although the plant originates from Ethiopia, it occurs in Kenya, Malawi, Uganda,.

  5. Liquid-liquid extraction combined with high performance liquid chromatography-diode array-ultra-violet for simultaneous determination of antineoplastic drugs in plasma

    Directory of Open Access Journals (Sweden)

    Ananda Lima Sanson

    2011-06-01

    Full Text Available A liquid-liquid extraction (LLE combined with high-performance liquid chromatography-diode array detection method for simultaneous analysis of four chemically and structurally different antineoplastic drugs (cyclophosphamide, doxorubicin, 5-fluorouracil and ifosfamide was developed. The assay was performed by isocratic elution, with a C18 column (5 µm, 250 x 4.6 mm and mobile phase constituted by water pH 4.0- acetonitrile-methanol (68:19:13, v/v/v, which allowed satisfactory separation of the compounds of interest. LLE, with ethyl acetate, was used for sample clean-up with recoveries ranging from 60 to 98%. The linear ranges were from 0.5 to 100 µg mL-1, for doxorubicin and 1 to 100 µg mL-1, for the other compounds. The relative standard deviations ranged from 5.5 to 17.7%. This method is a fast and simple alternative that can be used, simultaneously, for the determination of the four drugs in plasma, with a range enabling quantification of the drugs in pharmacokinetics, bioequivalence and therapeutic drug-monitoring studies.Um método de extração líquido-líquido (ELL combinado com cromatografia líquida de alta eficiência-detector de arranjo de diodos foi desenvolvido para análise simultânea de quatro fármacos antineoplásicos quimicamente e estruturalmente diferentes (ciclofosfamida, doxorrubicina, fluoruracila e ifosfamida. O estudo foi realizado sob condições isocráticas, com coluna C18 (5µm, 250 x 4.6 mm e fase móvel constituída por água pH 4.0-acetonitrila-metanol (68:19:13, v/v/v, que permitiu separação satisfatória dos analitos de interesse. A ELL, com acetato de etila, foi utilizada para limpeza da amostra, com recuperação variando de 60 a 98%. As faixas foram lineares de 0,5 a 100 µg mL-1 para doxorrubicina e 1 a 100 µg mL-1 para os outros compostos. O desvio padrão relativo variou de 5,5 a 17,7%. Este método é uma alternativa rápida e simples que pode ser usado, simultaneamente, para a determinação dos

  6. Multi-residue method for determination of seven neonicotinoid insecticides in grains using dispersive solid-phase extraction and dispersive liquid-liquid micro-extraction by high performance liquid chromatography.

    Science.gov (United States)

    Wang, P; Yang, X; Wang, J; Cui, J; Dong, A J; Zhao, H T; Zhang, L W; Wang, Z Y; Xu, R B; Li, W J; Zhang, Y C; Zhang, H; Jing, J

    2012-10-01

    A method using dispersive solid-phase extraction and dispersive liquid-liquid micro-extraction cleanup followed by high performance liquid chromatography (HPLC) has been established for determination of seven neonicotinoid insecticides residues in grains including brown rice, maize, millet and oat. Based on an appraisal of the characteristics of HPLC, validation experiments were conducted for seven neonicotinoid insecticides. In the method, dispersive solid-phase extraction was carried out using PSA and bonded C18 coupled with graphitised carbon black with acetonitrile as the eluted solvent. In the linear range of each pesticide, the correlation coefficient was R(2) ≥ 0.99. At the low, medium and high three fortification levels of 0.05-0.8 mg kg(-1), recoveries fell within 76-123%. The relative standard deviation was between 0.9% and 12.6% for seven neonicotinoid pesticides. Low limits of detection (0.002-0.005 mg kg(-1)) and quantification (0.007-0.018 mg kg(-1)) were readily achieved with this method for all tested pesticides. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Liquid-liquid extraction of uranium(VI) with Aliquat® 336 from HCl media in microfluidic devices: Combination of micro-unit operations and online ICP-MS determination.

    Science.gov (United States)

    Hellé, Gwendolyne; Mariet, Clarisse; Cote, Gérard

    2015-07-01

    The analysis of radionuclides is carried out according to operating protocols which include a series of chemical operations such as separation/purification steps and therefore is usually time-consuming, complex and difficult to put in place in a hostile environment (gloves box). In the present work, the liquid-liquid extraction of uranium in HCl media by Aliquat® 336 was performed in microsystem to demonstrate the potential of miniaturization in radiochemistry compared to classical protocols (decrease in volumes, analysis time, radiations received and feasibility of automation). Through the investigation of the influence of different parameters (flow rates, length of the microchannel, specific interfacial area), it was shown that the same performances of liquid-liquid extraction can be obtained in microsystem and in batch. Then, the coupling of different micro-unit operations for continuous process was performed to highlight the advantages of the miniaturized analytical techniques. The online ICP-MS determination of uranium(VI) was successfully coupled with the stripping of the latter from pre-loaded organic phases in microsystem, which constitutes a proof of concept and a first step towards a global analytical process with continuous flow. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Development and validation of an automated liquid-liquid extraction GC/MS method for the determination of THC, 11-OH-THC, and free THC-carboxylic acid (THC-COOH) from blood serum.

    Science.gov (United States)

    Purschke, Kirsten; Heinl, Sonja; Lerch, Oliver; Erdmann, Freidoon; Veit, Florian

    2016-06-01

    The analysis of Δ(9)-tetrahydrocannabinol (THC) and its metabolites 11-hydroxy-Δ(9)-tetrahydrocannabinol (11-OH-THC), and 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THC-COOH) from blood serum is a routine task in forensic toxicology laboratories. For examination of consumption habits, the concentration of the phase I metabolite THC-COOH is used. Recommendations for interpretation of analysis values in medical-psychological assessments (regranting of driver's licenses, Germany) include threshold values for the free, unconjugated THC-COOH. Using a fully automated two-step liquid-liquid extraction, THC, 11-OH-THC, and free, unconjugated THC-COOH were extracted from blood serum, silylated with N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA), and analyzed by GC/MS. The automation was carried out by an x-y-z sample robot equipped with modules for shaking, centrifugation, and solvent evaporation. This method was based on a previously developed manual sample preparation method. Validation guidelines of the Society of Toxicological and Forensic Chemistry (GTFCh) were fulfilled for both methods, at which the focus of this article is the automated one. Limits of detection and quantification for THC were 0.3 and 0.6 μg/L, for 11-OH-THC were 0.1 and 0.8 μg/L, and for THC-COOH were 0.3 and 1.1 μg/L, when extracting only 0.5 mL of blood serum. Therefore, the required limit of quantification for THC of 1 μg/L in driving under the influence of cannabis cases in Germany (and other countries) can be reached and the method can be employed in that context. Real and external control samples were analyzed, and a round robin test was passed successfully. To date, the method is employed in the Institute of Legal Medicine in Giessen, Germany, in daily routine. Automation helps in avoiding errors during sample preparation and reduces the workload of the laboratory personnel. Due to its flexibility, the analysis system can be employed for other liquid-liquid extractions as

  9. Comparison of micellar extraction combined with ionic liquid based vortex-assisted liquid-liquid microextraction and modified quick, easy, cheap, effective, rugged, and safe method for the determination of difenoconazole in cowpea.

    Science.gov (United States)

    Chen, Xiaochu; Bian, Yanli; Liu, Fengmao; Teng, Peipei; Sun, Pan

    2017-10-06

    Two simple sample pretreatment for the determination of difenoconazole in cowpea was developed including micellar extraction combined with ionic liquid based vortex-assisted liquid-liquid microextraction (ME-IL-VALLME) prior to high performance liquid chromatography (HPLC), and modified quick, easy, cheap, effective, rugged, and safe method (QuEChERS) coupled with HPLC-MS/MS. In ME-IL-VALLME method, the target analyte was extracted by surfactant Tween 20 micellar solution, then the supernatant was diluted with 3mL water to decrease the solubility of micellar solution. Subsequently, the vortex-assisted liquid-liquid microextraction (VALLME) procedure was performed in the diluted extraction solution by using the ionic liquid of 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM]PF6) as the extraction solvent and Tween 20 as an emulsifier to enhance the dispersion of the water-immiscible ionic liquid into the aqueous phase. Parameters that affect the extraction have been investigated in both methods Under the optimum conditions, the limits of quantitation were 0.10 and 0.05mgkg(-1), respectively. And good linearity was achieved with the correlation coefficient higher than 0.9941. The relative recoveries ranged from 78.6 to 94.8% and 92.0 to 118.0% with the relative standard deviations (RSD) of 7.9-9.6% and 1.2-3.2%, respectively. Both methods were quick, simple and inexpensive. However, the ME-IL-VALLME method provides higher enrichment factor compared with conventional QuEChERS method. The ME-IL-VALLME method has a strong potential for the determination of difenoconazole in complex vegetable matrices with HPLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Molecularly imprinted-solid phase extraction combined with simultaneous derivatization and dispersive liquid-liquid microextraction for selective extraction and preconcentration of methamphetamine and ecstasy from urine samples followed by gas chromatography.

    Science.gov (United States)

    Djozan, Djavanshir; Farajzadeh, Mir Ali; Sorouraddin, Saeed Mohammad; Baheri, Tahmineh

    2012-07-27

    In this study, a developed technique was reported for extraction and pre-concentration of methamphetamine (MAMP) and 3,4-methylenedioxymethamphetamine (MDMA, ecstasy) from urine samples using molecularly imprinted-solid phase extraction (MISPE) along with simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME). Molecularly imprinted microspheres as sorbent in solid phase extraction (SPE) procedure were synthesized using precipitation polymerization with MAMP as the template. Aqueous solution of the target analytes was passed through MAMP-MIP cartridge and the adsorbed analytes were then eluted with methanol. The collected eluate was mixed with butylchloroformate which served as the derivatization reagent as well as the extraction solvent. The mixture was immediately injected into deionized water. After centrifugation, 1 μL of the settled organic phase was injected into gas chromatography-flame ionization detection (GC-FID) or gas chromatography-mass spectrometry (GC-MS). Various experimental parameters affecting the performance of both of the steps (MISPE and DLLME) were thoroughly investigated. The calibration graphs were linear in the ranges of 10-1500 ng mL(-1) (MAMP) and 50-1500 ng mL(-1) (MDMA), and the detection limits (LODs) were 2 and 18 ng mL(-1), respectively. The relative standard deviations (%RSDs) obtained for six repeated experiments (100 ng mL(-1) of each drug) were 5.1% and 6.8% for MAMP and MDMA, respectively. The relative recoveries obtained for the analytes in human urine samples, spiked with different levels of each drug, were within the range of 80-88%. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. The Influence of Lactic Acid Concentration on the Separation of Light Rare Earth Elements by Continuous Liquid-Liquid Extraction with 2-Ethylhexyl Phosphonic Acid Mono-2-ethylhexyl Ester

    Science.gov (United States)

    de Carvalho Gomes, Rafael; Seruff, Luciana Amaral; Scal, Maira Labanca Waineraich; Vera, Ysrael Marrero

    2018-02-01

    The separation of rare earth elements (REEs) using solvent extraction adding complexing agents appears to be an alternative to saponification of the extractant. We evaluated the effect of lactic acid concentration on didymium (praseodymium and neodymium) and lanthanum extraction with 2-ethylhexyl phosphonic acid mono-2-ethyl hexyl ester [HEH(EHP)] as extractant. First, we investigated in batch experiments the separation of lanthanum (La) and didymium (Pr and Nd) using McCabe-Thiele diagrams to estimate the number of extraction stages when the feed solution was or was not conditioned with lactic acid. Additionally, we conducted continuous liquid-liquid extraction experiments and evaluated the influence of lactic acid concentration on the REE extraction and separation. The tests showed that the extraction percentage of REEs and the separation factor Pr/La increased when the lactic acid concentration increased, but the didymium purity decreased. Lanthanum, praseodymium, and neodymium extraction rate were 23.0, 89.7, and 99.2 pct, respectively, with 1:1 aqueous/organic volume flow rate and feed solution doped with 0.52 mol L-1 lactic acid. The highest didymium purity reached was 92.0 pct with 0.26 mol L-1 lactic acid concentration.

  12. The Influence of Lactic Acid Concentration on the Separation of Light Rare Earth Elements by Continuous Liquid-Liquid Extraction with 2-Ethylhexyl Phosphonic Acid Mono-2-ethylhexyl Ester

    Science.gov (United States)

    de Carvalho Gomes, Rafael; Seruff, Luciana Amaral; Scal, Maira Labanca Waineraich; Vera, Ysrael Marrero

    2017-11-01

    The separation of rare earth elements (REEs) using solvent extraction adding complexing agents appears to be an alternative to saponification of the extractant. We evaluated the effect of lactic acid concentration on didymium (praseodymium and neodymium) and lanthanum extraction with 2-ethylhexyl phosphonic acid mono-2-ethyl hexyl ester [HEH(EHP)] as extractant. First, we investigated in batch experiments the separation of lanthanum (La) and didymium (Pr and Nd) using McCabe-Thiele diagrams to estimate the number of extraction stages when the feed solution was or was not conditioned with lactic acid. Additionally, we conducted continuous liquid-liquid extraction experiments and evaluated the influence of lactic acid concentration on the REE extraction and separation. The tests showed that the extraction percentage of REEs and the separation factor Pr/La increased when the lactic acid concentration increased, but the didymium purity decreased. Lanthanum, praseodymium, and neodymium extraction rate were 23.0, 89.7, and 99.2 pct, respectively, with 1:1 aqueous/organic volume flow rate and feed solution doped with 0.52 mol L-1 lactic acid. The highest didymium purity reached was 92.0 pct with 0.26 mol L-1 lactic acid concentration.

  13. A rapid and simple pretreatment method for benzoylurea insecticides in honey samples using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids.

    Science.gov (United States)

    Wang, Huazi; Hu, Lu; Li, Wanzhen; Lu, Runhua; Zhang, Sanbing; Zhou, Wenfeng; Gao, Haixiang

    2016-11-04

    A pretreatment method using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids before high performance liquid chromatography analysis was developed for the determination of benzoylurea insecticides (BUs) in honey samples. The hydrophobic ionic liquid [N4444][PF6], formed in situ by the hydrophilic ionic liquid [N4444]Cl and the ion exchange reagent KPF6, was used to extract the target analytes. The entire extraction procedure was performed in a syringe. The extractant was solidified at room temperature and collected using a nylon membrane filter. This technique did not require a dispersive solvent, vortex mixer, ultrasound bath, or centrifugation. The parameters affecting the extraction efficiency were investigated through an experimental design. Under the optimal conditions, the limits of detection for the four BUs varied from 0.21 to 0.42μgL-1 in solution (2.1-4.2μgkg-1 in honey). Good linearities were obtained in the range of 2-300μgL-1, with coefficients of determination greater than 0.999. The recoveries of the four BUs ranged from 80.94% to 84.59%. The intra-day (n=3) and inter-day (n=3) relative standard deviations were less than 5.08%. Finally, the proposed method was applied to the determination of BUs in commercial honey samples with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples.

    Science.gov (United States)

    Liang, Ning; Huang, Peiting; Hou, Xiaohong; Li, Zhen; Tao, Lei; Zhao, Longshan

    2016-02-01

    A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16% to 99.80% with relative standard deviations between 0.7 and 8.4%. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.

  15. Liquid-liquid transfer phenomena studies coupled with redox reactions: back-extraction of nitrous acid in the presence of scavengers in aqueous phase; Etude de reactions d`oxydoreduction couplees a des phenomenes de transfert liquide-liquide: cas de la desextraction de l`acide nitreux en presence de composes antinitreux en phase aqueuse

    Energy Technology Data Exchange (ETDEWEB)

    K`zerho, R

    1998-12-31

    This work deals with the investigation of redox reaction contribution to the kinetics of liquid-liquid transfer, in relation with PUREX reprocessing of spent nuclear fuel. The chemical system chosen concerns the tripping of nitrous acid from tributylphosphate organic phase into a nitric acid aqueous solution containing an `anti-nitrous` component, namely hydrazinium nitrate. According to the abundant literature, a major attention is devoted to the very important role of interfacial phenomena on the kinetics of solvent extraction with tributylphosphate. Although, a suitable experimental technique is chosen, using a constant interfacial area cell of the ARMOLLEX-type. Furthermore, the effects of the hydrodynamical and the physico-chemical parameters on the extraction rate led to the identification of the extraction regime nature: diffusional, then chemical limitation. When no `anti-nitrous` component is used, the diffusional resistance is found to be mainly located in the aqueous diffusion layer. The presence of hydrazinium nitrate into the aqueous solution has an overall accelerating effect on the rate of extraction, related to both a complete suppression of the aqueous diffusional resistance, and a very significant enhancement of the interfacial transfer of the nitrous acid, as a function of hydrazinium concentration. If the first effect could be expected because of the well known fast redox reaction in aqueous phase, the second phenomenon represents a quite original and new result which has never been explored before, to the best of our knowledge. A reaction mechanism is postulated and validated, taking into account the reactive effect of hydrazinium on the interfacial step. In order to support the drawn general patterns, different complementary studies were attempted. When hydroxyl-ammonium nitrate is used, a surprising interfacial transfer blockage is observed, pointing out the extreme performance and specificity of the common hydrazinium component. (author) 99

  16. Simultaneous determination of pesticide residues and antioxidants in blended oil using a liquid-liquid extraction combined with dispersive solid phase extraction method.

    Science.gov (United States)

    Fang, Yong; Tian, Wen; Pei, Fei; Li, Peng; Shao, XiaoLong; Fan, Yan; Hu, Qiuhui

    2017-08-15

    This article developed a method to detect two antioxidants (butylated hydroxyl anisole (BHA), butylated hydroxyl toluene (BHT)) and twelve pesticides (dichlorvos, pirimicarb, prothiofos, fenitrothion, ethoprophos, malathion, beta-Cypermethrin, profenofos, diazinon, propoxur, procymidon, captan) in blended oil samples after their extraction simultaneously. The establishment of the method was based on two-step process of screening and optimization experiment design. With a Plackett-Burman (PB) design, significant parameters were found by screening experiment and single factor experiment accompanied by a central composite design (CCD) experiment were used to make important parameters optimal. The coefficients of determination (r(2)) was between 0.9931 and 0.9996 while the limits of quantification (LOQs) and limits of detection (LODs) were found in scope of 0.002-0.04mg·kg(-1) and 0.0006-0.0012mg·kg(-1). Recovery values of analytes were above 74%, at the same time the relative standard deviations (RSDs) under 10% at the concentrations ranging from 0.05mg·kg(-1) to 0.20mg·kg(-1). To sum up, this method with shorter time and fewer consumption of reagents could be employed in various occasions to detect antioxidants and pesticides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Molecular Dynamics Simulations on the solvation and interfacial behaviour of hydrophobic species. Applications to the TATB hypothesis and to the liquid/liquid extraction of cations to supercritical CO{sub 2}; Simulations par dynamique moleculaire de la solvatation et du comportement interfacial d'especes hydrophobes: application a l'hypothese TATB et a l'extraction liquide/liquide de cations par le CO{sub 2} supercritique

    Energy Technology Data Exchange (ETDEWEB)

    Schurhammer, R

    2001-12-15

    We report molecular dynamics studies on the solvation of charged hydrophobic molecules in pure liquids and at liquid / liquid interfaces. The first part of the thesis deals with the TATB hypothesis according to which the As{phi}{sub 4}{sup +} (TA{sup +}) and B{phi}{sub 4}{sup -} (TB{sup -}) ions have the same free energy of solvation in any solvent. The two ions are found to be solvated differently in pure liquids (water, chloroform, acetonitrile) as at a chloroform / water interface. These results are confirmed by free energy calculations and by simulations on iso-volume spherical S{sup +} and S{sup -} ions, which perfectly meet the TATB criteria. The many methodological tests performed show the importance of (i) the corrected treatment of 'long range interactions' (ii) the precise repartition of atomic charges (iii) the solvent models, especially for water, on the + / - charge discrimination by solvent. In the second part, in relation to the liquid / liquid extraction of cations from water to supercritical CO{sub 2}, we report the behaviour of ions (Cs{sup +}, UO{sub 2}{sup 2+}, Eu{sup 3+}), of un-complexed extractants molecules (tri-n-butylphosphate, calixarene), of their complexes with the cations and nitric acid at a preformed chloroform / water interface and during de-mixing simulations which started from a perfectly mixed CO{sub 2} / water solutions. These studies demonstrate the importance of interfacial phenomena, of simulation conditions and acid and extractant concentrations, in assisted ion extraction to supercritical CO{sub 2}. (author)

  18. Combination of microwave-assisted extraction and ultrasonic-assisted dispersive liquid-liquid microextraction for separation and enrichment of pyrethroids residues in Litchi fruit prior to HPLC determination.

    Science.gov (United States)

    Wang, Ke; Xie, Xiujuan; Zhang, Yi; Huang, Yuanxiang; Zhou, Shiyu; Zhang, Wei; Lin, Yuyang; Fan, Huajun

    2018-02-01

    A novel method for simultaneous determination of pyrethroids residues in Litchi fruit has been developed by HPLC-UV detection using microwave-assisted extraction (MAE) coupled with ultrasonic-assisted dispersive liquid-liquid microextraction (UADLLME). Extraction conditions of MAE and UADLLME were respectively investigated by single-factor experiments and response surface methodology. Optimized experimental conditions included 310μL of chlorobenzene as extraction solvent, 1.3mL of ethanol as dispersive solvent and 3min of extraction time for UADLLME. In the case of MAE, extraction temperature of 70°C, extraction time of 4min and solvent-to-materials ratio of 40:1 were adopted. Results demonstrated that the proposed method had good performance with linearity of 0.0050-4.98mg/L, recovery of 83.3-91.5%, RSDs below 5.6% and detection limit (LOD) of 1.15-2.46μg/L for six pyrethroids, offering higher extraction efficiency and larger enrichment factor. MAE-UADLLME provided a sensitive and efficient alternative to determination of trace amounts of pesticides residues in food samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    Science.gov (United States)

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in

  20. Combination of solid-phase extraction with dispersive liquid-liquid microextraction followed by GC-MS for determination of pesticide residues from water, milk, honey and fruit juice.

    Science.gov (United States)

    Shamsipur, Mojtaba; Yazdanfar, Najmeh; Ghambarian, Mahnaz

    2016-08-01

    In this work, an effective preconcentration method for the extraction and determination of traces of multi-residue pesticides was developed using solid-phase extraction (SPE) coupled with dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry (GC-MS). Variables affecting the performance of both extraction steps such as type and volume of elution and extraction solvents, breakthrough volume, salt addition, extraction time were thoroughly investigated. The proposed method resulted in good linearities (R(2)>0.9915) over the ranges of 1-10,000ngkg(-1), limits of detection (LODs) in the range of 0.5-1.0ngkg(-1) at S/N=3, and precision of RSD% of ⩽11.8. Under optimal conditions, the preconcentration factors were obtained in the range of 2362-10,593 for 100mL sample solutions. Comparison of the proposed method with other ones demonstrated that SPE-DLLME method provides higher extraction efficiency and larger preconcentration factor for determination of pesticides residues. Further, it is simple, inexpensive, highly sensitive, and can be successfully applied to separation, preconcentration and determination of the pesticides (and other noxious materials) in different real food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Accurate determination of 3-alkyl-2-methoxypyrazines in wines by gas chromatography quadrupole time-of-flight tandem mass spectrometry following solid-phase extraction and dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Fontana, Ariel; Rodríguez, Isaac; Cela, Rafael

    2017-09-15

    A new reliable method for the determination 3-alkyl-2-methoxypyrazines (MPs) in wine samples based on the sequential combination of solid-phase extraction (SPE), dispersive liquid-liquid microextraction (DLLME) and gas chromatography (GC) quadrupole time-of-flight accurate tandem mass spectrometry (QTOF-MS/MS) is presented. Primary extraction of target analytes was carried out by using a reversed-phase Oasis HLB (200mg) SPE cartridge combined with acetonitrile as elution solvent. Afterwards, the SPE extract was submitted to DLLME concentration using 0.06mL carbon tetrachloride (CCl4) as extractant. Under final working conditions, sample concentration factors above 379 times and limits of quantification (LOQs) between 0.3 and 2.1ngL(-1) were achieved. Moreover, the overall extraction efficiency of the method was unaffected by the particular characteristics of each wine; thus, accurate results (relative recoveries from 84 to 108% for samples spiked at concentrations from 5 to 25ngL(-1)) were obtained using matrix-matched standards, without using standard additions over every sample. Highly selective chromatographic records were achieved considering a mass window of 5mDa, centered in the quantification product ion corresponding to each compound. Twelve commercial wines, elaborated with grapes from different varieties and geographical origins, were processed with the optimized method. The 2-isobutyl-3-methoxypyrazine (IBMP) was determined at levels above the LOQs of the method in half of the samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A microfluidic platform for the rapid determination of distribution coefficients by gravity assisted droplet-based liquid-liquid extraction

    DEFF Research Database (Denmark)

    Poulsen, Carl Esben; Wootton, Robert C. R.; Wolff, Anders

    2015-01-01

    The determination of pharmacokinetic properties of drugs, such as the distribution coefficient, D, is a crucial measurement in pharmaceutical research. Surprisingly, the conventional (gold standard) technique used for D measurements, the shake-flask method, is antiquated and unsuitable for the te...

  3. Vortex-assisted micro-solid-phase extraction followed by low-density solvent based dispersive liquid-liquid microextraction for the fast and efficient determination of phthalate esters in river water samples.

    Science.gov (United States)

    Guo, Liang; Lee, Hian Kee

    2013-07-26

    A simple and efficient two-step method, vortex-assisted micro-solid-phase extraction (VA-μ-SPE) followed by low-density solvent based dispersive liquid-liquid microextraction (LDS-DLLME) combined with analysis by gas chromatography-mass spectrometry (GC-MS), was developed for the determination of trace level phthalate esters in environmental water samples. The analytes were firstly extracted and preconcentrated by vortex-assisted μ-SPE which was faster than conventional μ-SPE (6min compared to 30min), and then desorbed by ultrasonication into acetonitrile. The latter served as the dispersive solvent in the subsequent LDS-DLLME step which further pre-concentrated the analytes. Six phthalate esters were selected as model compounds for developing and evaluating the method. Some key parameters for VA-μ-SPE and LDS-DLLME, such as sorbent selection and amount, vortex time, ultrasonication solvent and time, extraction solvent type and volume for DLLME, the speed and time of centrifugation, were investigated. Under the most favorable conditions, good limits of detection (as low as 0.006μg/L) and repeatability of extraction (RSDs below 9.2%, n=5) were obtained. The developed method was applied to determine phthalate esters in environmental water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Combination of accelerated solvent extraction and vortex-assisted liquid-liquid microextraction for the determination of dimethyl fumarate in textiles and leathers by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Lu, Yang; Zhu, Yan

    2014-02-01

    A simple and environmentally friendly sample preparation procedure coupled with gas chromatography-mass spectrometry was developed to assay dimethyl fumarate in textiles and leathers. The sample preparation procedure involved an accelerated solvent extraction (ASE) using water as the extract solvent, followed by the extraction and concentration of dimethyl fumarate from the aqueous solution using vortex-assisted liquid-liquid microextraction (VALLME). The parameters affecting the ASE and VALLME were optimized to achieve the maximum extraction efficiency, and the performance of the developed method was evaluated. Good linearity was observed over the range assayed (0.01-1mg/kg) with a regression coefficient of 0.998. The limit of detection and enrichment factor for the VALLME step were 0.001 mg/kg and 53, respectively. The intra- and inter-day precision were below 8.9%, and the recovery was approximately 84-103%. The as-developed method was successfully applied to textiles and leather samples. © 2013 Elsevier B.V. All rights reserved.

  5. Towards quantification of toxicity of lithium ion battery electrolytes - development and validation of a liquid-liquid extraction GC-MS method for the determination of organic carbonates in cell culture materials.

    Science.gov (United States)

    Strehlau, Jenny; Weber, Till; Lürenbaum, Constantin; Bornhorst, Julia; Galla, Hans-Joachim; Schwerdtle, Tanja; Winter, Martin; Nowak, Sascha

    2017-10-01

    A novel method based on liquid-liquid extraction with subsequent gas chromatography separation and mass spectrometric detection (GC-MS) for the quantification of organic carbonates in cell culture materials is presented. Method parameters including the choice of extraction solvent, of extraction method and of extraction time were optimised and the method was validated. The setup allowed for determination within a linear range of more than two orders of magnitude. The limits of detection (LODs) were between 0.0002 and 0.002 mmol/L and the repeatability precisions were in the range of 1.5-12.9%. It could be shown that no matrix effects were present and recovery rates between 98 and 104% were achieved. The methodology was applied to cell culture models incubated with commercial lithium ion battery (LIB) electrolytes to gain more insight into the potential toxic effects of these compounds. The stability of the organic carbonates in cell culture medium after incubation was studied. In a porcine model of the blood-cerebrospinal fluid (CSF) barrier, it could be shown that a transfer of organic carbonates into the brain facing compartment took place. Graphical abstract Schematic setup for the investigation of toxicity of lithium ion battery electrolytes.

  6. Ultra-preconcentration and determination of thirteen organophosphorus pesticides in water samples using solid-phase extraction followed by dispersive liquid-liquid microextraction and gas chromatography with flame photometric detection.

    Science.gov (United States)

    Samadi, Soheila; Sereshti, Hassan; Assadi, Yaghoub

    2012-01-06

    An ultra-preconcentration technique composed of solid-phase extraction (SPE) and dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame photometric detection (GC-FPD) was used for determination of thirteen organophosphorus pesticides (OPPs) including phorate, diazinon, disolfotane, methyl parathion, sumithion, chlorpyrifos, malathion, fenthion, profenphose, ethion, phosalone, azinphose-methyl and co-ral in aqueous samples. The analytes were collected from large volumes of aqueous solutions (100 mL) into 100 mg of a SPE C(18) sorbent. The effective variables of SPE including type and volume of elution solvent, volume and flow rate of sample solution, and salt concentration were investigated and optimized. Acetone was selected as eluent in SPE and disperser solvent in DLLME and chlorobenzene was used as extraction solvent. Under the optimal conditions, the enrichment factors were between 15,160 and 21,000 and extraction recoveries were 75.8-105.0%. The linear range was 1-10,000 ng L(-1) and limits of detection (LODs) were between 0.2 and 1.5 ng L(-1). The relative standard deviations (RSDs) for 50 ng L(-1) of OPPs in water with and without an internal standard, were in the range of 1.4-7.9% (n=5) and 4.0-11.6%, respectively. The relative recoveries of OPPs from well and farm water sat spiking levels of 25 and 250 ng L(-1) were 88-109%. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Bio-dispersive liquid liquid microextraction based on nano rhaminolipid aggregates combined with magnetic solid phase extraction using Fe3O4@PPy magnetic nanoparticles for the determination of methamphetamine in human urine.

    Science.gov (United States)

    Haeri, Seyed Ammar; Abbasi, Shahryar; Sajjadifar, Sami

    2017-09-15

    In the present investigation, extraction and preconcentration of methamphetamine in human urine samples was carried out using a novel bio-dispersive liquid liquid microextraction (Bio-DLLME) technique coupled with magnetic solid phase extraction (MSPE). Bio-DLLME is a kind of microextraction technique based nano-materials which have potential capabilities in many application fields. Bio-DLLME is based on the use of a binary part system consisting of methanol and nano rhaminolipid biosurfactant. Use of this binary mixture is ecologically accepted due to their specificity, biocompatibility and biodegradable nature. The potential of nano rhaminolipid biosurfactant as a biological agent in the extraction of organic compounds has been investigated in recent years. They are able to partition at the oil/water interfaces and reduce the interfacial tension in order to increase solubility of hydrocarbons. The properties of the prepared Fe3O4@PPy magnetic nanoparticles were characterized using Fourier transform infrared spectroscopy and X-ray diffraction methods The influences of the experimental parameters on the quantitative recovery of analyte were investigated. Under optimized conditions, the enrichment factor was 310, the calibration graph was linear in the methamphetamine concentration range from 1 to 60μgL(-1), with a correlation coefficient of 0.9998. The relative standard deviations for six replicate measurements was 5.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Maghemite nanoparticle-decorated hollow fiber electromembrane extraction combined with dispersive liquid-liquid microextraction for the determination of thymol from Carum copticum

    DEFF Research Database (Denmark)

    Khajeh, Mostafa; Pedersen-Bjergaard, Stig; Bohlooli, Mousa

    2017-01-01

    BACKGROUND A novel technique using maghemite nanoparticle-decorated hollow fibers to assist electromembrane extraction is proposed. Electromembrane extraction combined with dispersive liquid–liquid microextraction (EME-DLLME) was applied for the extraction of thymol from Carum copticum, followed...... by gas chromatography with flame ionization detection (GC-FID). RESULTS The use of maghemite nanoparticle-decorated hollow fibers was found to improve the extraction efficiency of thymol significantly. Important operational parameters, including pH of acceptor phase, extraction time, voltage.......2% respectively. The intra- and inter-day accuracy was higher than 93.6%. CONCLUSION The results indicated that EME-DLLME/GC-FID is a useful technique for the extraction and determination of thymol in C copticum. © 2016 Society of Chemical Industry...

  9. Contribution of molecular modeling and of structure-activity relations to the liquid-liquid extraction. Application to the case of U(VI) extraction by monoamides; Apport de la modelisation moleculaire et des relations structure -activite a l`extraction liquide-liquide. Application au cas de l`extraction d`U(VI) par les monoamides

    Energy Technology Data Exchange (ETDEWEB)

    Rabbe, C.

    1996-06-07

    In France, spent fuels are in most cases reprocessed. The aim of the reprocessing is to separate the recyclable fissile materials (for instance, uranium and plutonium) of radioactive wastes. The industrial process used until now is the Purex (Plutonium Uranium Refining by EXtraction) process. Recently (1991), the CEA has undertaken researches on the fields of separation and transmutation of long-lived radionuclides as minor actinides. Some molecules with an amide function have been at first considered especially for the uranium extraction. In order to rationalize the research of new extracting molecules, some molecular modeling methods (quantum chemistry calculations, molecular mechanics) have been used. In fact, there are three determining parameters for a molecule to be a good extractant: it has to own: (1) one or several sites which present a sufficient electron density in order that the metallic cation be complexed (2) the smallest possible substituents to avoid interferences with the complexation (3) a sufficient lipophilic effect. (O.M.). 139 refs., 43 figs., 36 tabs.

  10. The feed forward neural network model for liquid-liquid extraction and separation of cobalt (II) from sodium acetate media using cyanex 272

    Science.gov (United States)

    Sudibyo, Aji, B. B.; Priyanto, S.

    2017-03-01

    Cobalt is one of the precious ferromagnetic metals, which widely used in the preparation of magnetic, wear-resistant and high-strength alloys. This metal was not found naturally in single metal form but is found as impurities in nickel or copper ore. The extraction process is one of the methods to separate cobalt from its impurities. However, this process needs an expensive organic solution. In practice, changing the composition of chemicals composition in extraction process always affect at a high cost. Therefore, the development of the artificial neural network (ANN) model to model the cobalt extraction process can serve as an important tool for predicting and investigating the optimum production for the cobalt extraction without the need to run the actual experiment. Hence, the development of the ANN model of cobalt extraction model is essential to simulate the process, which can lead to high yields of cobalt production. In this work a selected optimum multiple-input-single-output (MISO) model of feed forward neural network (FFNN) was used to predict the percentage of cobalt extraction. MISO FFNN with 20, 30 and 50 hidden nodes were used to simulate cobalt extraction process. The simulation results achieved was compared with data available in the literature. The results show that MISO FFNN with 50 hidden nodes has the best performance. The optimum result of MISO FFNN then exported to Simulink model in Matlab environment, hence make it easy to use in predicting and investigating for the optimum production of the cobalt extraction.

  11. Development and application of salting-out assisted liquid/liquid extraction for multi-mycotoxin biomarkers analysis in pig urine with high performance liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Song, Suquan; Ediage, Emmanuel Njumbe; Wu, Aibo; De Saeger, Sarah

    2013-05-31

    Direct determination of urinary mycotoxins is a better approach to assess individual's exposure than the indirect estimation from average dietary intakes. In this study, a new analytical method was developed and validated for simultaneous analysis of aflatoxin B1, deoxynivalenol, fumonisin B1, ochratoxin A, zearalenone and T2 toxin and their metabolites in pig urine. In total 12 analytes were selected. A salting-out assisted liquid-liquid extraction procedure was used for sample preparation. High performance liquid chromatography/tandem mass spectrometry was used for the separation and detection of all the analytes. The extraction recoveries were in a range of 70-108%, with the intra-day relative standard deviation and inter-day relative standard deviation lower than 25% for most of the compounds at 3 different concentration levels. Meanwhile the method bias for all the analytes did not exceed 20%. The limits of quantification ranged from 0.07ngmL(-1) for ochratoxin A to 3.3ngmL(-1) for deoxynivalenol. Matrix effect was evaluated in this study and matrix-matched calibration was used for quantification. The developed method was also validated for human urine as an extension of its application. Finally, the developed method was applied in a pilot study to analyze 28 pig urine samples. Deoxynivalenol, aflatoxin B1, fumonisin B1 and ochratoxin A were detected in these samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Enzyme-assisted extraction and ionic liquid-based dispersive liquid-liquid microextraction followed by high-performance liquid chromatography for determination of patulin in apple juice and method optimization using central composite design.

    Science.gov (United States)

    Mohammadi, Abdorreza; Tavakoli, Rouya; Kamankesh, Marzieh; Rashedi, Hamid; Attaran, Abdolmohammad; Delavar, Mostafa

    2013-12-04

    A simple and highly sensitive analytical methodology for isolation and determination of patulin in apple-juice samples, based on enzyme-assisted extraction (EAE) and ionic liquid-based dispersive liquid-liquid microextraction (IL-DLLME) was developed and optimized. Enzymes play essential roles in eliminating interference and increasing the extraction efficiency of patulin. Apple-juice samples were treated with pectinase and amylase. A mixture of 80 μL ionic liquid and 600 μL methanol (disperser solvent) was used for the IL-DLLME process. The sedimented phase was analyzed by high-performance liquid chromatography (HPLC). Experimental parameters controlling the performance of DLLME, were optimized using response surface methodology (RSM) based on central composite design (CCD). Under optimum conditions, the calibration curves showed high levels of linearity (R(2)>0.99) for patulin in the range of 1-200 ng g(-1). The relative standard deviation (RSD) for the seven analyses was 7.5%. The limits of detection (LOD) and limits of quantification (LOQ) were 0.15 ng g(-1) and 0.5 ng g(-1), respectively. The merit figures, compared with other methods, showed that new proposed method is an accurate, precise and reliable sample-pretreatment method that substantially reduces sample matrix interference and gives very good enrichment factors and detection limits for investigation trace amount of patulin in apple-juice samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Simultaneous determination of bisphenol A and bisphenol B in beverages and powdered infant formula by dispersive liquid-liquid micro-extraction and heart-cutting multidimensional gas chromatography-mass spectrometry.

    Science.gov (United States)

    Cunha, S C; Almeida, C; Mendes, E; Fernandes, J O

    2011-04-01

    The purpose of this study was to establish a reliable, cost-effective, fast and simple method to quantify simultaneously both bisphenol A (BPA) and bisphenol B (BPB) in liquid food matrixes such as canned beverages (soft drinks and beers) and powdered infant formula using dispersive liquid-liquid micro-extraction (DLLME) with in-situ derivatisation coupled with heart-cutting gas chromatography-mass spectrometry (GC-MS). For the optimisation of the DLLME procedure different amounts of various extractive and dispersive solvents as well as different amounts of the derivative reagent were compared for their effects on extraction efficiency and yields. The optimised procedure consisted of the injection of a mixture containing tetrachloroethylene (extractant), acetonitrile (dispersant) and acetic anhydride (derivatising reagent) directly into an aliquot of beverage samples or into an aqueous extract of powdered milk samples obtained after a pretreatment of the samples. Given the compatibility of the solvents used, and the low volumes involved, the procedure was easily associated with GC-MS end-point determination, which was accomplished by means of an accurate GC dual column (heart-cutting) technique. Careful optimisation of heart-cutting GC-MS conditions, namely pressure of front and auxiliary inlets, have resulted in a good analytical performance. The linearity of the matrix-matched calibration curves was acceptable, with coefficients of determination (r2) always higher than 0.99. Average recoveries of the BPA and BPB spiked at two concentration levels into beverages and powdered infant formula ranged from 68% to 114% and the relative standard deviation (RSD) was market.

  14. Mathematical modeling of liquid/liquid hollow fiber membrane contactor accounting for interfacial transport phenomena: Extraction of lanthanides as a surrogate for actinides

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, J.D.

    1994-08-04

    This report is divided into two parts. The second part is divided into the following sections: experimental protocol; modeling the hollow fiber extractor using film theory; Graetz model of the hollow fiber membrane process; fundamental diffusive-kinetic model; and diffusive liquid membrane device-a rigorous model. The first part is divided into: membrane and membrane process-a concept; metal extraction; kinetics of metal extraction; modeling the membrane contactor; and interfacial phenomenon-boundary conditions-applied to membrane transport.

  15. Salting-out assisted liquid-liquid extraction for the determination of biogenic amines in fruit juices and alcoholic beverages after derivatization with 1-naphthylisothiocyanate and high performance liquid chromatography.

    Science.gov (United States)

    Jain, Archana; Gupta, Manju; Verma, Krishna K

    2015-11-27

    A new method for determining biogenic amines in fruit juices and alcoholic beverages is described involving reaction of biogenic amines with 1-naphthylisothiocyanate followed by extraction of 1-naphthylthiourea derivatives with water-miscible organic solvent acetonitrile when solvents phase separation occurred using ammonium sulphate, a process called salting-out assisted liquid-liquid extraction. The extract was analyzed by high-performance liquid chromatography with UV detection at 254nm. The new reagent avoided many of the inconveniences as observed with existing derivatizing agents, such as dansyl chloride and benzoyl chloride, in regard to their inselectivity, instability, adverse effect of excess reagent, and necessity to remove excess reagent. The procedure has been optimized with respect to reaction time and temperature, water-miscible extraction solvent, and salt for solvents phase separation. Use of reagent as dispersed phase in aqueous medium produced derivatives in high yield. A linear calibration was obtained between the amount of biogenic amines in range 1-1000μgL(-1) and peak areas of corresponding thioureas formed; the correlation coefficient was 0.9965, and the limit of detection and limit of quantification found were 1.1μgL(-1) and 3.2μgL(-1), respectively. The pre-concentration method gave an average enrichment factor of 94. The application of the method has been demonstrated in the determination of biogenic amines in commercial samples of fruit juices and alcoholic beverages. In spiking experiments to real samples, the average recovery found by the present method was 94.5% that agreed well with 95.8% obtained by established comparison methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Determination of methylphenidate in Calliphorid larvae by liquid-liquid extraction and liquid chromatography mass spectrometry - Forensic entomotoxicology using an in vivo rat brain model

    DEFF Research Database (Denmark)

    Bushby, Sarah K.; Thomas, Nicky; Priemel, Petra A.

    2012-01-01

    The aim of this study was to examine the potential forensic utilisation of blowfly larvae (Diptera: Calliphoridae) as an alternative toxicological specimen for the detection of the psychotropic model drug methylphenidate (MPH). MPH was extracted from biological matrices (rat brain, serum and Call......The aim of this study was to examine the potential forensic utilisation of blowfly larvae (Diptera: Calliphoridae) as an alternative toxicological specimen for the detection of the psychotropic model drug methylphenidate (MPH). MPH was extracted from biological matrices (rat brain, serum...

  17. Liquid-Liquid Equilibrium data for mono ethylene glycol extraction from water with the new ionic liquid tetraoctyl ammonium 2-methyl-1-naphtoate as solvent

    NARCIS (Netherlands)

    Garcia Chavez, L.Y.; Schuur, Boelo; de Haan, A.B.

    2012-01-01

    Thermal recovery of mono ethylene glycol (MEG) from aqueous streams is one of the most energy demanding operations in industry, because of the large amount of water that needs to be evaporated. The use of alternative technologies such as liquid–liquid extraction could save energy. A new tailor made

  18. Ultrasonic-assisted extraction and dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as an efficient and sensitive method for determining of acrylamide in potato chips samples.

    Science.gov (United States)

    Zokaei, Maryam; Abedi, Abdol-Samad; Kamankesh, Marzieh; Shojaee-Aliababadi, Saeedeh; Mohammadi, Abdorreza

    2017-11-01

    In this research, for the first time, we successfully developed ultrasonic-assisted extraction and dispersive liquid-liquid microextraction combined with gas chromatography-mass spectrometry as a new, fast and highly sensitive method for determining of acrylamide in potato chips samples. Xanthydrol was used as a derivatization reagent and parameters affecting in the derivatization and microextraction steps were studied and optimized. Under optimum conditions, the calibration curves showed high levels of linearity (R2>0.9993) for acrylamide in the range of 2-500ngmL-1. The relative standard deviation (RSD) for the seven analyses was 6.8%. The limit of detection (LOD) and limit of quantification (LOQ) were 0.6ngg-1 and 2ngg-1, respectively. The UAE-DLLME-GC-MS method demonstrated high sensitivity, good linearity, recovery, and enrichment factor. The performance of the new proposed method was evaluated for the determination of acrylamide in various types of chips samples and satisfactory results were obtained. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Production of Valuable Lipophilic Compounds by Using Three Types of Interface Bioprocesses: Solid-Liquid Interface Bioreactor, Liquid-Liquid Interface Bioreactor, and Extractive Liquid-Surface Immobilization System.

    Science.gov (United States)

    Oda, Shinobu

    2017-01-01

    Bioconversions such as enzymatic and microbial transformations are attractive alternatives to organic synthesis because of practical advantages such as resource conservation, energy efficiency, and environmentally harmonic properties. In addition, the production of secondary metabolites through microbial fermentation is also useful for manufacturing pharmaceuticals, agricultural chemicals, and aroma compounds. For microbial production of useful chemicals, the authors have developed three unique interfacial bioprocesses: a solid-liquid interface bioreactor (S/L-IBR), a liquid-liquid interface bioreactor (L/L-IBR), and an extractive liquid-surface immobilization (Ext-LSI) system. The S/L-IBR comprises a hydrophobic organic solvent (upper phase), a microbial film (middle phase), and a hydrophilic gel such as an agar plate (lower phase); the L/L-IBR and the Ext-LSI consist of a hydrophobic organic solvent (upper phase), a fungal mat with ballooned microspheres (middle phase), and a liquid medium (lower phase). All three systems have unique and practically important characteristics such as utilization of living cells, high concentration of lipophilic substrates/products in an organic phase, no requirement for aeration and agitation, efficient supply of oxygen, easy recovery of product, high regio- and stereoselectivity, and wide versatility. This paper reviews the principle, construction, characteristics, and application of these interfacial systems for producing lipophilic compounds such as useful aroma compounds, citronellol-related compounds, β-caryophyllene oxide, and 6-penty-α-pyrone.

  20. A Novel Two-Step Liquid-Liquid Extraction Procedure Combined with Stationary Phase Immobilized Human Serum Albumin for the Chiral Separation of Cetirizine Enantiomers along with M and P Parabens.

    Science.gov (United States)

    Chmielewska, Aleksandra; Konieczna, Lucyna; Bączek, Tomasz

    2016-12-07

    The research into the separation of drug enantiomers is closely related to the safety and efficiency of the drugs. The aim of this study was to develop a simple and validated HPLC method to analyze cetirizine enantiomers. In the case of liquid dosage forms, besides the active substance in large amounts there are usually also inactive ingredients such as methyl- and propylparaben. Unfortunately, these compounds can interfere with the analyte, inter alia during chiral separation of the analyte enantiomers. The proposed innovative two-step liquid-liquid extraction procedure allowed for the determination of cetirizine enantiomers (along with M and P parabens) also in liquid dosage forms. The main focus of this study was the chromatographic activity of cetirizine dihydrochloride on the proteinate-based chiral stationary phase. The chromatographic separation of cetirizine enantiomers was performed on an immobilized human serum albumin (HSA) column for the first time. Measurements were performed at a wavelength of 227 nm. Under optimal conditions, baseline separation of two enantiomers was obtained with 1.43 enantioseparation factor (α) and 1.82 resolution (Rs). Finally, the proposed method was successfully applied to the selected pharmaceutical formulations.

  1. A Novel Two-Step Liquid-Liquid Extraction Procedure Combined with Stationary Phase Immobilized Human Serum Albumin for the Chiral Separation of Cetirizine Enantiomers along with M and P Parabens

    Directory of Open Access Journals (Sweden)

    Aleksandra Chmielewska

    2016-12-01

    Full Text Available The research into the separation of drug enantiomers is closely related to the safety and efficiency of the drugs. The aim of this study was to develop a simple and validated HPLC method to analyze cetirizine enantiomers. In the case of liquid dosage forms, besides the active substance in large amounts there are usually also inactive ingredients such as methyl- and propylparaben. Unfortunately, these compounds can interfere with the analyte, inter alia during chiral separation of the analyte enantiomers. The proposed innovative two-step liquid-liquid extraction procedure allowed for the determination of cetirizine enantiomers (along with M and P parabens also in liquid dosage forms. The main focus of this study was the chromatographic activity of cetirizine dihydrochloride on the proteinate-based chiral stationary phase. The chromatographic separation of cetirizine enantiomers was performed on an immobilized human serum albumin (HSA column for the first time. Measurements were performed at a wavelength of 227 nm. Under optimal conditions, baseline separation of two enantiomers was obtained with 1.43 enantioseparation factor (α and 1.82 resolution (Rs. Finally, the proposed method was successfully applied to the selected pharmaceutical formulations.

  2. Identification of alkaloid constituents from Fangchi species using pH control liquid-liquid extraction and liquid chromatography coupled to quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Sim, Hee-Jung; Yoon, Soo Hwan; Kim, Min Sun; Kim, Byungjoo; Park, Hyun-Mee; Hong, Jongki

    2015-05-15

    Fangchi (F.) species from four different origins have been widely used to treat or prevent diseases, and their main constitutes are several types of alkaloids. Identification of alkaloids in F. species is a necessary step to understand the therapeutic properties of each different origin, but this has not yet been fully performed. Several types of alkaloids were extracted from F. species using ultrasonication with 70% CH(3)OH and the extract was partitioned at pH 2 and 12 to enrich alkaloid constituents and to remove interferences. The separation of alkaloids in the Fangchi extract was performed on a C18 column using gradient elution and their tandem mass spectra were obtained by quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) to perform accurate mass measurements of fragment ions for the alkaloid constituents. Several types of alkaloids were successfully separated and identified by LC/ESI-MS/MS. The structural assignment of individual alkaloids was performed based on convergence of MS/MS spectral data, pH partitioning behavior, LC retention behavior, and accurate mass measurements. The pH partition of the extract provided structural information about unknown alkaloids extracted from Fangchi species. A total of 28 compounds were identified and tentatively characterized, and of these 10 alkaloids were reported for the first time in the investigated F. species. The chemical profiling of alkaloids in F. species with different origins was performed for the first time and provided diagnostic ions for diverse alkaloids in F. species. Marker compounds were suggested based on the 28 characterized compounds for quality evaluation and the differentiation of Fangchi species with four different origins. Copyright © 2015 John Wiley & Sons, Ltd.

  3. On the stoichiometry and stability of americium(III) complexes with a hydrophilic SO3-Ph-BTP ligand, studied by liquid-liquid extraction.

    Science.gov (United States)

    Steczek, Łukasz; Rejnis, Magdalena; Narbutt, Jerzy; Charbonnel, Marie-Christine; Moisy, Philippe

    1:1 and 1:2 complexes of americium(III) with a hydrophilic anionic SO 3 -Ph-BTP 4- ligand were detected in acidic aqueous nitrate solutions by a solvent extraction method. The determined conditional stability constants of these complexes, log β 1  = 4.35 ± 0.07 and log β 2  = 7.67 ± 0.06, related to 1 M aqueous solutions, are much lower than the literature values for the analogous curium species, determined by TRLFS in very dilute aqueous solutions. There is also no evidence for the existence of the 1:3 Am 3+ complex similar to the reported curium(III) complex. A hypothesis has been formulated to explain these discrepancies. It suggests the necessity to carefully check the equilibria in each phase of solvent extraction systems containing two competing ligands-lipophilic and hydrophilic.

  4. Liquid-liquid extraction of Pu(IV), U(VI) and Am(III) using malonamide in room temperature ionic liquid as diluent.

    Science.gov (United States)

    Rout, Alok; Venkatesan, K A; Srinivasan, T G; Vasudeva Rao, P R

    2012-06-30

    The extraction behavior of U(VI), Pu(IV) and Am(III) from nitric acid medium by a solution of N,N-dimethyl-N,N-dioctyl-2-(2-hexyloxyethyl)malonamide (DMDOHEMA) in the room temperature ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (C(4)mimNTf(2)), was studied. The distribution ratio of these actinides in DMDOHEMA/C(4)mimNTf(2) was measured as a function of various parameters such as the concentration of nitric acid, DMDOHEMA, NTf(2)(-), alkyl chain length of ionic liquid. The extraction of actinides in the absence of DMDOHEMA was insignificant and the distribution ratio achieved in conjunction with C(4)mimNTf(2), was remarkable. The separation factor of U(VI) and Pu(IV) achieved with the use of DMDOHEMA, ionic liquid was compared with Am(III) and other fission products. The stoichiometry of the metal-solvate was determined to be 1:2 for U(VI) and Pu(IV) and 1:3 for Am(III). Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Determination of tin, vanadium, iron, and molybdenum in various matrices by atomic absorption spectrometry using a simultaneous liquid-liquid extraction procedure.

    Science.gov (United States)

    Sánchez-Viñas, M; Bagur, G M; Gázquez, D; Camino, M; Romero, R

    1999-01-01

    An atomic-absorption spectrometric method is described for the determination of tin, vanadium, iron, and molybdenum in two certified reference materials, food samples, and petroleum crude. After treatment with acids, these elements are separated from matrix elements by simultaneous solvent extraction of 5,5'-methylenedisalicylohydroxamic acid complexes from HCl/NaClO4 solution into an isobutyl methyl ketone/tributyl phosphate solution. The detection limits range from 0.018 to 0.19 microg/mL (n = 3), and the relative standard deviations do not exceed 2.0% at levels of 0.5, 0.6, 2.0, and 7.0 microg/mL of Fe, Mo, V, and Sn, respectively. The method is selective and suffers only from interference by Zr(IV), Ti(IV), Th(IV), W(VI), PO4(3-), and F-.

  6. Liquid-liquid extraction of cadmium(II by TIOACl (tri-iso-octylammonium chloride ionic liquid and its application to a TIOACl impregnated carbon nanotubes system

    Directory of Open Access Journals (Sweden)

    Alguacil, Francisco J.

    2015-09-01

    Full Text Available The extraction of cadmium(II by the ionic liquid (R3NH+Cl- (R: tri-iso-octyl in Exxsol D100 from hydrochloric acid solution has been investigated. The extraction reaction is exothermic. The numerical analysis of metal distribution data suggests the formation of R3NH+CdCl3− and (R3NH+2CdCl42− species in the organic phase. The results obtained for cadmium(II distribution have been implemented in an impregnated multi-walled carbon nanotubes system. The influence of aqueous solution stirring speed (250–2000 min−1, adsorbent dosage (0.05–0.2 g and temperature (20 °C–60 °C on cadmium adsorption have been investigated.Se ha estudiado la extracción de cadmio(II, de disoluciones en medio HCl, por el líquido iónico (R3NH+Cl- (R: tri-iso-octyl disuelto en Exxsol D100. La reacción de extracción tiene un carácter exotérmico. El análisis numérico de la distribución del metal sugiere la formación de las especies R3NH+CdCl3− y (R3NH+2CdCl42− en la fase orgánica. Estos resultados se han implementado en un sistema que utiliza nanotubos de carbono de pared múltiple impregnados con este líquido iónico. Se han investigado diversas variables experimentales: velocidad de agitación de la disolución acuosa (250–2000 min−1, adición del adsorbente (0,05–0,2 g y temperatura (20–60 °C.

  7. Development of a high-throughput method for the determination of itraconazole and its hydroxy metabolite in human plasma, employing automated liquid-liquid extraction based on 96-well format plates and LC/MS/MS.

    Science.gov (United States)

    Kousoulos, Constantinos; Tsatsou, Georgia; Apostolou, Constantinos; Dotsikas, Yannis; Loukas, Yannis L

    2006-01-01

    A semi-automated liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed for the simultaneous quantification of the antifungal drug itraconazole (ITZ) and its coactive metabolite hydroxyitraconazole (OH-ITZ) in human plasma. The plasma samples underwent liquid-liquid extraction (LLE) in 2.2 mL 96 deepwell plates. ITZ, OH-ITZ and the internal standard (IS) R51012 were extracted from plasma, using a mixture of acetonitrile (ACN) and methyl t-butyl ether (MTBE) as the organic solvent. This specific mixture, due to its composition, had a significant impact on the performance of the assay. All liquid transfer steps, including preparation of calibration standards and quality control samples as well as the addition of the IS, were performed automatically using robotic liquid handling workstations for parallel sample processing. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated. The analytes and IS were dissolved in a small volume of a reconstitution solution, an aliquot of which was analyzed by combined reversed phase LC/MS/MS, with positive ion electrospray ionization and a TurboIonSpray interface, using multiple reactions monitoring (MRM). The method was shown to be sensitive and specific to both ITZ and OH-ITZ, it revealed excellent linearity for the range of concentrations 2-500 ng mL(-1) for ITZ and 4-1000 ng mL(-1) for OH-ITZ, it was very accurate and it gave very good inter- and intra-day precisions. The proposed high-throughput method was employed in a bioequivalence study after per os administration of two 100 mg tablets of ITZ, and it allowed this study to be completed in under four days.

  8. A high-throughput, fully automated liquid/liquid extraction liquid chromatography/mass spectrometry method for the quantitation of a new investigational drug ABT-869 and its metabolite A-849529 in human plasma samples.

    Science.gov (United States)

    Rodila, Ramona C; Kim, Joseph C; Ji, Qin C; El-Shourbagy, Tawakol A

    2006-01-01

    ABT-869 is a novel ATP-competitive inhibitor for all the vascular endothelial growth factor (VEGF) and platelet-derived growth factor (PDGF) receptor tyrosine kinases (RTKs). It is one of the oncology drugs in development at Abbott Laboratories and has great potential for enhanced anti-tumor efficacy as well as activity in a broad range of human cancers. We report here an accurate, precise and rugged liquid chromatography/mass spectrometry (LC/MS/MS) assay for the quantitative measurement of ABT-869 and its acid metabolite A-849529. A fully automated 96-well liquid/liquid extraction method was achieved utilizing a Hamilton liquid handler. The only manual intervention required prior to LC/MS/MS injection is to transfer the 96-well plate to a drying rack to dry the extracts then transfer the plate back to the Hamilton for robotic reconstitution. The linear dynamic ranges were from 1.1 to 598.8 ng/mL for ABT-869 and from 1.1 to 605.8 ng/mL for A-849529. The coefficient of determination (r2) for all analytes was greater than 0.9995. For the drug ABT-869, the intra-assay coefficient of variance (CV) was between 0.4% and 3.7% and the inter-assay CV was between 0.9% and 2.8%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.8% and 102.2%. For the metabolite A-849529, the intra-assay CV was between 0.5% and 5.1% and the inter-assay CV was between 0.8% and 4.9%. The inter-assay mean accuracy, expressed as percent of theoretical, was between 96.9% and 100.6%. Copyright 2006 John Wiley & Sons, Ltd.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in whole water by continuous liquid-liquid extraction and capillary-column gas chromatography with flame photometric detection

    Science.gov (United States)

    Jha, Virendra K.; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 organophosphate pesticide degradates from natural-water samples is described. Compounds are extracted from water samples with methylene chloride using a continuous liquid-liquid extractor for 6 hours. The solvent is evaporated using heat and a flow of nitrogen to a volume of 1 milliliter and solvent exchanged to ethyl acetate. Extracted compounds are determined by capillary-column gas chromatography with flame photometric detection. Single-operator derived method detection limits in three water-matrix samples ranged from 0.003 to 0.009 microgram per liter. Method performance was validated by spiking all compounds in three different matrices at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of most method compounds spiked in surface-water samples ranged from 54 to 137 percent and those in ground-water samples ranged from 40 to 109 percent for all pesticides. Recoveries in reagent-water samples ranged from 42 to 104 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had variable recovery in all three matrices ranging from 27 to 79 percent. As a result, the detected concentration of O-ethyl-O-methyl-S-propylphosphorothioate in samples is reported in this method with an estimated remark code. Based on the performance issue, two more compounds, disulfoton and ethion monoxon, also will be reported in this method with an estimated remark code. Estimated-value compounds, which are ?E-coded? in the data base, do not meet the performance criteria for unqualified quantification, but are retained in the method because the compounds are important owing to high use or potential environmental effects and because analytical performance has been consistent and reproducible.

  10. Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid-liquid extraction.

    Science.gov (United States)

    Taibi, G; Nicotra, C M A

    2002-11-25

    A sensitive HPLC assay for all-trans-retinol, alpha-tocopherol, and gamma-tocopherols in human serum and plasma is reported. Sample preparation is performed in one step and involves precipitation of proteins and extraction of lipids with two volumes of an ethanol-chloroform mixture (3:1, v/v) without I.S. addition. After removal of the precipitated protein, 20 microl aliquots of the supernatant (equivalent to 6.7 microl of serum or plasma) were injected into the HPLC system and analyzed using fluorometric detection. RP-HPLC was performed using a C(18) S3 ODS2 column with a methanol-water step gradient (97:3 to 100) at 1.0 ml/min. The quantification limit expressed as nanograms of analyte per milliliter of serum or plasma was approximately 30 ng for all-trans-retinol, 300 ng for alpha-tocopherol and 250 ng for gamma- and delta-tocopherol. The method was validated and applied to human serum and plasma from a total of 120 subjects. This procedure requires a small volume of serum or plasma and can therefore be a valuable tool for measuring low concentrations of these vitamins in preterm infants with sensitivity, precision and accuracy. Copyright 2002 Elsevier Science B.V.

  11. Extractive liquid-liquid spectrofluorometric determination of trace and ultra concentrations of bromate in water samples by the fluorescence quenching of tetraphenylphosphonium iodide

    Science.gov (United States)

    Al-Saidi, H. M.; El-Shahawi, M. S.

    2015-03-01

    A low cost and selective spectrofluorimetric method has been developed for trace determination of bromate ions in water. The method has been based upon complete extraction of the produced yellow colored ion associate of the reagent tetraphenylphosphonium iodide (TPP+ I-) and bromate ions from aqueous media into chloroform and measuring the fluorescence quenching at λex/em = 242/305 nm. The composition, stability and the most probable mechanism of the produced associate have been determined. The plot of fluorescence intensity of TPP+ I-vs. bromate concentration was linear in the range 0.86-150.0 μg L-1. The limits of detection (LOD) and quantification (LOQ) of BrO3- were 0.24 and 0.76 μg L-1, respectively. The method was found free from most of the interferences present in chromatographic, spectrofluorometric and spectrophotometric methods. Intra and inter-day laboratory accuracy and precision for analysis of bromate in water were determined. The method provides better performance compared to the international standard method recently issued (ISO 11206:2011). The method was applied satisfactorily for analysis of 1.0 μg L-1 bromate in the presence of high excess of chloride (50 mg/L) without pretreatment with a relative standard deviation (RSD) of ±2.9%. The method was applied for analysis of bromate in various water samples. Statistical comparison of the results of the proposed method with those obtained by the standard method revealed no significant differences in the accuracy and precision.

  12. Simultaneous liquid-liquid extraction of dibenzyl disulfide, 2,6-di-tert-butyl-p-cresol, and 1,2,3-benzotriazole from power transformer oil prior to GC and HPLC determination.

    Science.gov (United States)

    Jaber, Abdul Muttaleb Yousef; Mehanna, Nemr Ahmed; Abulkibash, Abdalla Mahmoud

    2012-03-01

    2,6-Di-tert-butyl-p-cresol (DBPC), dibenzyl disulfide (DBDS), and 1,2,3-benzotriazole (BTA) are additives that may be found concomitantly in the oil matrix of power transformer. DBPC and DBDS act as antioxidants while, BTA is a corrosion inhibitor that protects copper conductors inside the transformer unit from corrosion. A powerful analytical method is, therefore, required to determine these additives at trace levels in the transformer oil. This work describes a unique single liquid-liquid extraction pretreatment step prior to the determination of the components by gas chromatography (GC) and high-performance liquid chromatography (HPLC) techniques. The optimum volume ratio used in the pretreatment step was determined as 5:2:5 for mineral oil/n-hexane/acetonitrile, respectively. Relatively, the method is simple and quick with a minimal use of solvents. Analytical results indicate that the method is relatively sensitive, accurate, and precise for each of the three components in fresh and used mineral oil. The calibration curves for the three components demonstrate a significant increase in sensitivities. Detection limits found were, 100 mg L(-1) (0.01% w/v), 0.80 mg L(-1) , and 2.04 mg L(-1) for DBPC, DBDS, and BTA, respectively. The Student's t values determined at 95% confidence level indicate that there is no significant difference between the experimental means obtained by this method and the standard method for each component. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Development and validation of a multi-residue method for pesticide determination in honey using on-column liquid-liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Pirard, C; Widart, J; Nguyen, B K; Deleuze, C; Heudt, L; Haubruge, E; De Pauw, E; Focant, J-F

    2007-06-08

    We report on the development and validation under ISO 17025 criteria of a multi-residue confirmatory method to identify and quantify 17 widely chemically different pesticides (insecticides: Carbofuran, Methiocarb, Pirimicarb, Dimethoate, Fipronil, Imidacloprid; herbicides: Amidosulfuron, Rimsulfuron, Atrazine, Simazine, Chloroturon, Linuron, Isoxaflutole, Metosulam; fungicides: Diethofencarb) and 2 metabolites (Methiocarb sulfoxide and 2-Hydroxytertbutylazine) in honey. This method is based on an on-column liquid-liquid extraction (OCLLE) using diatomaceous earth as inert solid support and liquid chromatography (LC) coupled to mass spectrometry (MS) operating in tandem mode (MS/MS). Method specificity is ensured by checking retention time and theoretical ratio between two transitions from a single precursor ion. Linearity is demonstrated all along the range of concentration that was investigated, from 0.1 to 20 ng g(-1) raw honey, with correlation coefficients ranging from 0.921 to 0.999, depending on chemicals. Recovery rates obtained on home-made quality control samples are between 71 and 90%, well above the range defined by the EC/657/2002 document, but in the range we had fixed to ensure proper quantification, as levels found in real samples could not be corrected for recovery rates. Reproducibility is found to be between 8 and 27%. Calculated CCalpha and CCbeta (0.0002-0.943 ng g(-1) for CCalpha, and 0.0002-1.232 ng g(-1) for CCbeta) show the good sensitivity attained by this multi-residue analytical method. The robustness of the method has been tested in analyzing more than 100 raw honey samples collected from different areas in Belgium, as well as some wax and bee samples, with a slightly adapted procedure.

  14. Dummy-surface molecularly imprinted polymers as a sorbent of micro-solid-phase extraction combined with dispersive liquid-liquid microextraction for determination of five 2-phenylpropionic acid NSAIDs in aquatic environmental samples.

    Science.gov (United States)

    Guo, Ping; Yuan, Xucan; Zhang, Jingjing; Wang, Binjie; Sun, Xiaoyang; Chen, Xiaohui; Zhao, Longshan

    2018-01-01

    environmental fate and risk to ecological health. Graphical abstract Dummy-surface molecularly imprinted polymers as a sorbent of micro-solid-phase extraction combined with dispersive liquid-liquid microextraction for determination of five 2-phenylpropionic acid NSAIDs in aquatic environmental samples.

  15. Countercurrent liquid-liquid extraction on paper

    NARCIS (Netherlands)

    Salentijn, Gert Ij; Grajewski, Maciej; Verpoorte, Elisabeth

    2017-01-01

    Proof-of-concept is shown for two-phase countercurrent flow on paper. The device consists of two paper layers, one of which has been modified with a sizing agent to be hydrophobic. The layers exhibit different wetting behavior for water and octanol. Both phases dominate wetting in one of the layers

  16. Dispersive liquid-liquid microextraction combined with acetonitrile stacking through capillary electrophoresis for the determination of three selective serotonin reuptake inhibitor drugs in body fluids.

    Science.gov (United States)

    Lin, En-Ping; Chiu, Tai-Chia; Hsieh, Ming-Mu

    2016-12-01

    Dispersive liquid-liquid microextraction was combined with acetonitrile stacking in capillary electrophoresis for the identification of three selective serotonin reuptake inhibitors (citalopram, fluoxetine, and fluvoxamine) in human fluids such as urine and plasma. Parameters that affect the extraction and stacking efficiency, such as the type and volume of the extraction and disperser solvent, extraction time, salt addition for dispersive liquid-liquid microextraction, and sample matrices, pH, and concentration of the separation buffer for stacking, were investigated and optimized. Under optimum conditions, the enrichment factors were in the range of 1195-1441. Limits of detection ranged from 1.4 to 1.7 nM for the target analytes. Calibration graphs displayed satisfied linearity with R(2) greater than or equal to 0.9978, and relative standard deviations of the peak area analysis were in the range of 2.9-5.0% (n = 3). The recoveries of all tricyclic antidepressant drugs from urine and plasma were in the range of 77-117 and 79-106%, respectively. The findings of this study show that dispersive liquid-liquid microextraction acetonitrile-stacking capillary electrophoresis is a rapid and convenient method for identifying tricyclic antidepressant drugs in urine and plasma. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Towards a physical interpretation of third phase formation in liquid-liquid extraction. Application to the Diamex process for the treatment of high radioactive nuclear wastes; Vers une interpretation physique des phenomenes de troisieme phase en extraction liquide-liquide. Application au procede Diamex de traitement des effluents radioactifs de haute activite

    Energy Technology Data Exchange (ETDEWEB)

    Verdier-Erlinger, C

    1998-07-24

    Using SAXS, conductivity and phase behaviour determination we show that concentrated solutions of extractants are organised in reverse oligomeric aggregates which have many features in common with reverse micelles. The aggregation numbers of these reverse globular aggregates as well as their interaction potential are determined experimentally. The sticky sphere interaction is responsible for the de-mixing on the oil phase when in equilibrium with excess oil. Prediction of conductivity as well as formation condition for the third phase is possible using standard liquid theory applied to the reverse micelles. The attractive interaction, modeled with the sticky sphere model proposed by Baxter, is the balance of steric stabilisation introduced by the hydrophobic tails of the extracting molecule and the Van der Waals forces between the highly polarizable water core of the reverse molecule concentration, number of carbon atoms of aliphatic solvents, as well as proton and Neodymium cation concentration. It is shown that van der Waals interactions with a Hamaker constant of 2.5 kT explains the behaviour of DMDBTDMA in dodecane. (author) 184 refs.

  18. Extração líquido-líquido de urânio(VI do colofanito de itataia (Santa Quitéria, Ceará por extratantes orgânicos em presença de ácido fosfórico Liquid-liquid extraction of uranium(VI from colofanite of itataia (Santa Quitéria, Ceará by organic extractants in the presence of phosphoric acid

    Directory of Open Access Journals (Sweden)

    Valeria Aparecida Leitão Ribeiro

    2008-01-01

    Full Text Available This work describes the liquid-liquid extraction of uranium after digestion of colofanite (a fluoroapatite from Itataia with sulfuric acid. The experiments were run at room temperature in one stage. Among the solutions tested the highest distribution coefficient (D > 60 was found for 40%vol. DEHPA (di(2-ethyl-hexylphosphoric acid + 20% vol. TOPO (trioctylphosphine oxide in kerosene. Thorium in the raffinate was quantitatively extracted by TOPO (0.1% vol. in cyclohexane. Uranium stripping and separation from iron was possible using 1.5 mol L-1 ammonium or sodium carbonate (room temperature, one stage. However, pH control is essential for a good separation.

  19. Operation with three liquid phases in a staged liquid-liquid contactor

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, R.A.; Ziegler, A.A.; Wigeland, R.A.; Bane, R.W.; Steindler, M.J.

    1983-03-01

    Operation with three liquid phases was demonstrated in a staged liquid-liquid contactor. The possibility that three liquid phases could be handled in a liquid-liquid contactor normally used with two liquid phases was initially established using a laboratory batch test. Tht three liquid phases were obtained using a thorium flow sheet having high concentrations of both acid and thorium. To analyze the batch test, the concept of a dimensionless dispersion number for use with two liquid phases was extended so that it could be applied to three liquid phases. Based on the batch tests, continuous flow tests were run in a staged liquid-liquid contactor used for solvent extraction. A critical factor in the success of these tests was determining the position of the liquid-liquid interface in the contactor. Thus, a contactor was used which allows the position of the liquid-liquid interface to be adjusted. Actual three-phase operation was demonstrated using a 4-cm annular centrifugal contactor, albeit with a somewhat greater (3 to 4 vol. %) aqueous-phase contamination of the organic exit stream than normal (< 1 vol. %).

  20. Molecular and supramolecular speciations of solvent extraction systems based on malonamide and/or dialkyl-phosphoric acids for An(III)/Ln(III); Speciations moleculaire et supramoleculaire de systemes d'extraction liquide-liquide a base de malonamide et/ou d'acides dialkylphosphoriques pour la separation An(III)/Ln(III)

    Energy Technology Data Exchange (ETDEWEB)

    Gannaz, B

    2006-06-15

    The solvent extraction system used in the DIAMEX-SANEX process, developed for the actinide(III)/lanthanide(III) separation, is based on the use of mixtures of the malonamide DMDOHEMA and a dialkyl-phosphoric acid (HDEHP or HDHP), in hydrogenated tetra-propylene. The complexity of these systems urges on a novel approach to improve the conventional methods (thermodynamics, solvent extraction) which hardly explain the macroscopic behaviors observed (3. phase, over-stoichiometry). This approach combines studies on both supramolecular (VPO, SANS, SAXS) and molecular (liquid-liquid extraction, ESI-MS, IR, EXAFS) speciations of single extractant systems (DMDOHEMA or HDHP in in n-dodecane) and their mixture. In spite of safety constraints due to the handling of radio-material, they were used in the studies as much as possible, like for SAXS measurements on americium-containing samples, a worldwide first-time. In each of the investigated systems, actinides(III) and lanthanides(III) are extracted to the organic phase in polar cores of reversed micelles, the inner and outer-sphere compositions of which are proposed. Thus, the 4f and 5f cations are extracted by reversed micelles such as [(DMDOHEMA){sub 2}M(NO{sub 3}){sub 3}]{sub inn} (DMDOHEMA){sub x}(HNO{sub 3}){sub z}(H{sub 2}O){sub w}]{sub out} and M(DHP){sub 3}(HDHP){sub y-3}(H{sub 2}O){sub w} with y = 3 to 6, for the single extractant systems. In the case of the two extractants system, the less concentrated one acts like a co-surfactant regarding the mixed aggregate formation [(DMDOHEMA){sub 2}M(NO{sub 3}){sub 3-v}(DHP){sub v}]{sub inn} [(DMDOFIEMA){sub x}(HDHP){sub y}(HNO{sub 3})z(H{sub 2}O){sub w}]{sub out}. (author)

  1. Theoretical and experimental investigation into the explosive boiling potential of thermally stratified liquid-liquid systems

    NARCIS (Netherlands)

    Fabiano, B.; Kersten, R.J.A.; Opschoor, G.; Pastorino, R.

    2002-01-01

    The occurrence of a rapid phase transition, or so-called explosive boiling, when a cold volatile liquid comes into contact with a hot liquid or hot surface is a potential hazard in industry. This study was focused on the explosive boiling potential of thermally stratified liquid-liquid systems that

  2. Preconcentration of uranium in water samples using dispersive liquid-liquid micro- extraction coupled with solid-phase extraction and determination with inductively coupled plasma-optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    M. Rezaee,

    2015-10-01

    Full Text Available A new liquid phase microextraction method based on the dispersion of an extraction solvent into aqueous phase coupled with solid-phase extraction was investigated for the extraction, preconcentration and determination of uranium in water samples. 1-(2-Pyridylazo-2-naphthol reagent (PAN at pH 6.0 was used as a chelating agent prior to extraction. After concentration and purification of the samples in SPE C18 sorbent, 1.5 mL elution sample containing 40.0 µL chlorobenzene was injected into the 5.0 mL pure water. After extraction and centrifuging, the sedimented phase was evaporated and the residue was dissolved in nitric acid (0.5 M and was injected by injection valve into the ICP-OES. Some important extraction parameters, such as sample solution flow rate, sample pH, type and volume of extraction and disperser solvents as well as the salt addition were studied and optimized. Under the optimum conditions, the calibration graph was linear in the range of 0.5-500 µg L-1. The detection limit was 0.1 µg L-1. The relative standard deviation (RSD at 5.0 µg L-1 concentration level was 6.6%. Finally, the developed method was successfully applied to the extraction and determination of uranium in the well, river, mineral, waste and tap water samples and satisfactory results were obtained.DOI: http://dx.doi.org/10.4314/bcse.v29i3.4

  3. Liquid-liquid distribution of aromatic α-amino acids in multicomponent systems

    Science.gov (United States)

    Korenman, Ya. I.; Mokshina, N. Ya.; Pakhomova, O. A.

    2010-02-01

    Distribution coefficients and recovery factors of phenylalanine, tyrosine, and tryptophan are measured in extraction systems with butanol, pentanol, acetone, and ethyl acetate, their binary and ternary mixtures, and water-soluble polymers. Extraction conditions—extractant composition, salting-out agents, and pH—are optimized. Efficient systems providing maximum quantitative characteristics of the process of liquid-liquid distribution of aromatic α-amino acids are proposed.

  4. Liquid-liquid extraction (LLE) of Fe(III) and Ti(IV) by bis-(2-ethyl-hexyl) phosphoric acid (D2EHPA) in sulfuric acid medium; Extracao liquido-liquido de ferro (III) e titanio (IV) pelo acido bis-(2-etil-hexil) fosforico (D2EHPA) em meio de acido sulfurico

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Glauco Correa da; Cunha, Jose Waldemar Silva Dias da [Instituto de Engenharia Nuclear (IEN), Rio de Janeiro, RJ (Brazil). Dept. de Quimica e Materiais Nucleares; Dweck, Jo [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola de Quimica. Dept. de Processos Inorganicos; Afonso, Julio Carlos [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Quimica. Dept. de Quimica Analitica]. E-mail: julio@iq.ufrj.br

    2008-07-01

    This work presents a study on the separation of Fe(III) and Ti(IV) from sulfuric acid leaching solutions of ilmenite (FeTiO{sub 3}) using liquid-liquid extraction with D2EHPA in n-dodecane as extracting agent. The distribution coefficients (K{sub D}) of the elements related to free acidity and concentration of Fe(III) and Ti(IV) were determined. Free acidity was changed from 3x10{sup -2} to 11.88 mol L{sup -1} and D2EHPA concentration was fixed at 1.5 mol L{sup 1}. Recovery of final products as well as recycling of wastes generated in the process were also investigated. The LLE process as a feasible alternative to obtain high-purity TiO{sub 2}. (author)

  5. Reversed-phase vortex-assisted liquid-liquid microextraction: a new sample preparation method for the determination of amygdalin in oil and kernel samples.

    Science.gov (United States)

    Hosseini, Mohammad; Heydari, Rouhollah; Alimoradi, Mohammad

    2015-02-01

    A novel, simple, and rapid reversed-phase vortex-assisted liquid-liquid microextraction coupled with high-performance liquid chromatography has been introduced for the extraction, clean-up, and preconcentration of amygdalin in oil and kernel samples. In this technique, deionized water was used as the extracting solvent. Unlike the reversed-phase dispersive liquid-liquid microextraction, dispersive solvent was eliminated in the proposed method. Various parameters that affected the extraction efficiency, such as extracting solvent volume and its pH, vortex, and centrifuging times were evaluated and optimized. The calibration curve shows good linearity (r(2) = 0.9955) and precision (RSD < 5.2%) in the range of 0.07-20 μg/mL. The limit of detection and limit of quantitation were 0.02 and 0.07 μg/mL, respectively. The recoveries were in the range of 96.0-102.0% with relative standard deviation values ranging from 4.0 to 5.1%. Unlike the conventional extraction methods for plant extracts, no evaporative and re-solubilizing operations were needed in the proposed technique. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Optimisation of ultrasound-assisted reverse micelles dispersive liquid-liquid micro-extraction by Box-Behnken design for determination of acetoin in butter followed by high performance liquid chromatography.

    Science.gov (United States)

    Roosta, Mostafa; Ghaedi, Mehrorang; Daneshfar, Ali

    2014-10-15

    A novel approach, ultrasound-assisted reverse micelles dispersive liquid-liquid microextraction (USA-RM-DLLME) followed by high performance liquid chromatography (HPLC) was developed for selective determination of acetoin in butter. The melted butter sample was diluted and homogenised by n-hexane and Triton X-100, respectively. Subsequently, 400μL of distilled water was added and the microextraction was accelerated by 4min sonication. After 8.5min of centrifugation, sedimented phase (surfactant-rich phase) was withdrawn by microsyringe and injected into the HPLC system for analysis. The influence of effective variables was optimised using Box-Behnken design (BBD) combined with desirability function (DF). Under optimised experimental conditions, the calibration graph was linear over the range of 0.6-200mgL(-1). The detection limit of method was 0.2mgL(-1) and coefficient of determination was 0.9992. The relative standard deviations (RSDs) were less than 5% (n=5) while the recoveries were in the range of 93.9-107.8%. Copyright © 2014. Published by Elsevier Ltd.

  7. Trace analysis of three antihistamines in human urine by on-line single drop liquid-liquid-liquid microextraction coupled to sweeping micellar electrokinetic chromatography and its application to pharmacokinetic study.

    Science.gov (United States)

    Gao, Wenhua; Chen, Yunsheng; Chen, Gaopan; Xi, Jing; Chen, Yaowen; Yang, Jianying; Xu, Ning

    2012-09-01

    A rapid and efficient dual preconcentration method of on-line single drop liquid-liquid-liquid microextraction (SD-LLLME) coupled to sweeping micellar electrokinetic chromatography (MEKC) was developed for trace analysis of three antihistamines (mizolastine, chlorpheniramine and pheniramine) in human urine. Three analytes were firstly extracted from donor phase (4 mL urine sample) adjusted to alkaline condition (0.5 M NaOH). The unionized analytes were subsequently extracted into a drop of n-octanol layered over the urine sample, and then into a microdrop of acceptor phase (100 mM H(3)PO(4)) suspended from a capillary inlet. The enriched acceptor phase was on-line injected into capillary with a height difference and then analyzed directly by sweeping MEKC. Good linear relationships were obtained for all analytes in a range of 6.25 × 10(-6) to 2.5 × 10(-4)g/L with correlation coefficients (r) higher than 0.987. The proposed method achieved limits of detections (LOD) varied from 1.2 × 10(-7) to 9.5 × 10(-7)g/L based on a signal-to-noise of 3 (S/N=3) with 751- to 1372-fold increases in detection sensitivity for analytes, and it was successfully applied to the pharmacokinetic study of three antihistamines in human urine after an oral administration. The results demonstrated that this method was a promising combination for the rapid trace analysis of antihistamines in human urine with the advantages of operation simplicity, high enrichment factor and little solvent consumption. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Macromolecular sensing at the liquid-liquid interface

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Gregoire; Flynn, Shane [Tyndall National Institute, Lee Maltings, University College, Cork (Ireland); Arrigan, Damien W M, E-mail: gregoire.herzog@tyndall.ie [Nanochemistry Research Institute, Department of Chemistry, Curtin University, Perth (Australia)

    2011-08-17

    We report here the electrochemical sensing of macromolecules, such as polyLysine dendrimers, at the polarised liquid | liquid interface. Electrochemistry at the liquid | liquid interface is a powerful analytical technique which allows the detection of non-redox active molecules via ion transfer reactions at a polarised water - oil interface. We demonstrate here that different parameters of the polyLysine dendrimers (charge number, molecular weight) have a strong influence on the sensitivity and limit of detection of these macromolecules. This work will help to the development of sensors based on charge transfer at the liquid | liquid interface.

  9. Determination of organophosphorus pesticides in soil by dispersive liquid-liquid microextraction and gas chromatography.

    Science.gov (United States)

    Yang, Zhonghua; Liu, Yu; Liu, Donghui; Zhou, Zhiqiang

    2012-01-01

    In this article, a rapid and sensitive sample pretreatment technique for the determination of organophosphorus pesticides (OPPs) in soil samples is developed by using dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography-flame photometric detection. Experimental conditions, including the kind of extraction and disperser solvent and their volumes, the extraction time, and the salt addition, are investigated, and the following experiment factors are used: 20 µL chlorobenzene as the extraction solvent; 1.0 mL acetonitrile as the disperser solvent; no addition of salt; and an extraction time of 1 min. Under the optimum conditions, the linearities for the three target OPPs (ethoprophos, chlorpyriphos, and profenofos) are obtained by five points in the concentration range of 2.5-1500 µg/kg, and three replicates are used for each point. Correlation coefficients vary from 0.9987 to 0.9997. The repeatability is tested by spiking soil samples at a concentration level of 5.0 µg/kg. The relative standard deviation (n = 3) varied between 2.0% and 6.6%. The limits of detection, based on a signal-to-noise ratio (S/N) of 3, range from 200 to 500 pg/g. This method is applied to the analysis of the spiked samples S1, S2, and S3, which are collected from the China Agriculture University's orchard, lawn, and garden, respectively. The recoveries for each target analyte are in the range between 87.9% and 108.0%, 87.4% and 108.0%, and 86.7% and 107.2%, respectively. © The Author [2011]. Published by Oxford University Press. All rights reserved.

  10. Surface nanodroplets for highly efficient liquid-liquid microextraction

    Science.gov (United States)

    Li, Miaosi; Lu, Ziyang; Yu, Haitao; Zhang, Xuehua

    2016-11-01

    Nanoscale droplets on a substrate are an essential element for a wide range of applications, such as laboratory-on-chip devices, simple and highly efficient miniaturized reactors for concentrating products, high-throughput single-bacteria or single-biomolecular analysis, encapsulation, and high-resolution imaging techniques. The solvent exchange process is a simple bottom-up approach for producing droplets at solid-liquid interfaces that are only several tens to hundreds of nanometers in height, or a few femtoliters in volume Oil nanodroplets can be produced on a substrate by solvent exchange in which a good solvent of oil is displaced by a poor solvent. Our previous work has significantly advanced understanding of the principle of solvent exchange, and the droplet size can be well-controlled by several parameters, including flow rates, flow geometry, gravitational effect and composition of solutions. In this work, we studied the microextraction effect of surface nanodroplets. Oil nanodroplets have been demonstrated to provide highly-efficient liquid-liquid microextraction of hydrophobic solute in a highly diluted solution. This effect proved the feasibility of nanodroplets as a platform for preconcentrating compounds for in situ highly sensitive microanalysis without further separation. Also the long lifetime and temporal stability of surface nanodroplets allow for some long-term extraction process and extraction without addition of stabilisers.

  11. Time-resolved potentiometry on liquid-liquid interface

    OpenAIRE

    Mansfeldová, Věra

    2017-01-01

    MSc. Věra Mansfeldová Dissertation thesis: Time-resolved potentiometry on liquid-liquid interface Abstract The aim of this work is to explore the method of temporal resolution in potentiometry as a new prospective electrochemical analytical technique. In connection with interface of two immiscible electrolyte solutions (ITIES) it may find utilization in analytical chemistry. This technique up to my knowledge has not been published yet. Potential response of analyte on liquid/liquid interface ...

  12. Analysis of amantadine in biological fluids using hollow fiber-based liquid-liquid-liquid microextraction followed by corona discharge ion mobility spectrometry.

    Science.gov (United States)

    Saraji, Mohammad; Khayamian, Taghi; Mirmahdieh, Shiva; Bidgoli, Ali Akbar Hajialiakbari

    2011-10-15

    A method based on liquid-liquid-liquid microextraction combined with corona discharge ion mobility spectrometry was developed for the analysis of amantadine in human urine and plasma samples. Amantadine was extracted from alkaline aqueous sample as donor phase through a thin phase of organic solvent (n-dodecane) filling the pores of the hollow fiber wall and then back extracted into the organic acceptor phase (methanol) located in the lumen of the hollow fiber. All variables affecting the extraction of analyte including acceptor organic solvent type, concentration of NaOH in donor phase, ionic strength of the sample and extraction time were studied. The linear range was 20-1000 and 5-250 ng/mL for plasma and urine, respectively (r(2)≥0.990). The limits of detection were calculated to be 7.2 and 1.6 ng/mL for plasma and urine, respectively. The relative standard deviation was lower than 8.2% for both urine and plasma samples. The enrichment factors were between 45 and 54. The method was successfully applied for the analysis of amantadine in urine and plasma samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. The Development of a Droplet Formation and Entrainment Model for Simulations of Immiscible Liquid-Liquid Flows

    Science.gov (United States)

    1999-01-01

    formation was that performed by Hayworth and Treybal [19], who studied drop formation of a liquid dispersion from simple nozzles of one liquid into...34Liquid-Liquid Extraction: Part IV - A Further Study of Hold-Up in Packed Columns," Trans. Inst. Chem. Eng. 31: 57. [19] Hayworth, C. and Treybal

  14. Spectrophotometric determination of uranium with arsenazo previous liquid-liquid extraction and colour development in organic medium; Determinacion espectrofotometrica de uranio con arsenazo, previa extraccion y desarrollo del color en medio organico

    Energy Technology Data Exchange (ETDEWEB)

    Palomares Delgado, F.; Vera Palomino, J.; Petrement Eguiluz, J. C.

    1964-07-01

    The determination of uranium with arsenazo is hindered by a great number of cation which form stable complexes with the reactive and may given rise to serious interferences. By studying the optimum conditions of uranium the extraction be means of tributylphosphate solutions dissolved in methylisobuthylketone, under conditions for previous masking of the interfering cations, an organic extract was obtained containing all the uranium together with small amounts of iron. The possible interference derived from the latter element is avoided by reduction with hydroxylammoniumchlorid followed by complex formation of the Fe(II)-ortophenantroline compound in alcoholic medium. (Author) 17 refs.

  15. A validated method for simultaneous screening and quantification of twenty-three benzodiazepines and metabolites plus zopiclone and zaleplone in whole blood by liquid-liquid extraction and ultra-performance liquid chromatography- tandem mass spectrometry

    DEFF Research Database (Denmark)

    Simonsen, Kirsten Wiese; Hermansson, Sigurd; Steentoft, Anni

    2010-01-01

    , oxazepam, temazepam, triazolam, zaleplon, and zopiclone. Whole blood from drug-free volunteers was used for all experiments. Blood samples (0.200 g) were extracted with ethyl acetate at pH 9. Target drugs were quantified using a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple...... quadrupole in positive electrospray ionization, multiple reaction monitoring mode. The use of deuterated internal standards for most compounds verified that the accuracy of the method was not influenced by matrix effects. Extraction recoveries were 73-108% for all analytes. Lower limits of quantification...

  16. A comparative evaluation of the liquid-liquid extraction and pertraction efficiency of a both-side diglycolamide-functionalized calix[4]arene with analogous upper and lower-rim calixarenes for actinide separations

    NARCIS (Netherlands)

    Mohapatra, P.K.; Rout, D.R.; Iqbal, M.; Huskens, Jurriaan; Verboom, Willem

    2013-01-01

    A lower-rim (L-I), an upper-rim (L-II), and a both-side (L-III) diglycolamide-functionalized calix[4]arene were evaluated for the extraction of actinide ions such as UO22+, Pu4+, and Am3+ and fission product element ions such as Eu3+, Cs+, and Sr2+ from dilute nitric acid feed solutions. Conditions

  17. Liquid-liquid Slug Flow in a Microchannel Reactor and its Mass Transfer Properties - A Review

    Directory of Open Access Journals (Sweden)

    Rahul Antony

    2014-10-01

    Full Text Available Mass transfer is a basic phenomenon behind many processes like reaction, absorption, extraction etc. Mass transfer plays a significant role in microfluidic systems where the chemical / biological process systems are shrinkened down to a micro scale. Micro reactor system, with its high compatibility and performance, gains a wide interest among the researchers in the recent years. Micro structured reac-tors holds advantages over the conventional types in chemical processes. The significance of micro re-actor not limited to its scalability but to energy efficiency, on-site / on-demand production, reliability, safety, highly controlled outputs, etc. Liquid-liquid two phase reaction in a microreactor system is highly demandable when both reactants are liquids or when air medium cannot be suitable. This arti-cle overviews various liquid-liquid flow regimes in a microchannel. Discussions on the hydrodynamics of flow in micro scale are made. Considering the importance of mass transfer in liquid-liquid systems and the advantage of slug regime over other regimes, the article focuses especially on the mass trans-fer between two liquid phases in slug flow and the details of experimental studies carried out in this area. The advantages of slug flow over other flow regimes in micro structured reactor applications are showcased. © 2014 BCREC UNDIP. All rights reservedReceived: 31st May 2014; Revised: 6th August 2014; Accepted: 14th August 2014How to Cite: Antony, R., Giri Nandagopal, M.S., Sreekumar, N., Rangabhashiyam, S., Selvaraju, N. (2014. Liquid-liquid Slug Flow in a Microchannel Reactor and its Mass Transfer Properties - A Review. Bulletin of Chemical Reaction Engineering & Catalysis,9(3: 207-223. (doi:10.9767/bcrec.9.3.6977.207-223Permalink/DOI: http://dx.doi.org/10.9767/bcrec.9.3.6977.207-223

  18. Spectrophotometric determination of Sudan Blue II in environmental samples after dispersive liquid-liquid microextraction

    Directory of Open Access Journals (Sweden)

    Yunus Emre Unsal

    2014-01-01

    Full Text Available A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride, volume of dispersant (ethanol, volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.

  19. Response surface methodology for the optimization of dispersive liquid-liquid microextraction of chloropropanols in human plasma.

    Science.gov (United States)

    Gonzalez-Siso, Paula; Lorenzo, Rosa A; Regenjo, María; Fernández, Purificación; Carro, Antonia M

    2015-10-01

    Chloropropanols are processing toxicants with a potential risk to human health due to the increased intake of processed foods. A rapid and efficient method for the determination of three chloropropanols in human plasma was developed using ultrasound-assisted dispersive liquid-liquid microextraction. The method involved derivatization and extraction in one step followed by gas chromatography with tandem mass spectrometry analysis. Parameters affecting extraction, such as sample pH, ionic strength, type and volume of dispersive and extraction solvents were optimized by response surface methodology using a pentagonal design. The linear range of the method was 5-200 ng/mL for 1,3-dichloro-2-propanol, 10-200 ng/mL for 2,3-dichloro-2-propanol and 10-400 ng/mL for 3-chloropropane-1,2-diol with the determination coefficients between 0.9989 and 0.9997. The limits of detection were in the range of 0.3-3.2 ng/mL. The precision varied from 1.9 to 10% relative standard deviation (n = 9). The recovery of the method was between 91 and 101%. Advantages such as low consumption of organic solvents and short time of analysis make the method suitable for the biomonitoring of chloropropanols. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Determination of organochlorine pesticides in snow water samples by low density solvent based dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Zhao, Wenting; Li, Jindong; Wu, Tong; Wang, Peng; Zhou, Zhiqiang

    2014-09-01

    A simple, rapid, efficient, and environmentally friendly pretreatment based on a low-density solvent based dispersive liquid-liquid microextraction was developed for determining trace levels of 17 organochlorine pesticides in snow. The parameters affecting the extraction efficiency, such as the type and volume of the extraction and dispersive solvents, extraction time, and salt content, were optimized. The optimized conditions yielded a good performance, with enrichment factors ranging from 271 to 474 and recoveries ranging from 71.4 to 114.5% and relative standard deviations between 1.6 and 14.8%. The detection limits, calculated as three times the signal-to-noise ratio, ranged from 0.02 to 0.11 μg/L. The validated method was used to successfully analyze 17 analytes in snow water samples, overcoming the drawbacks of some existing low-density solvent liquid microextraction methods, which require special devices, large volumes of organic solvents, or complicated operation procedures. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Development of on-line spectroscopic determination approach of dispersive liquid-liquid microextraction based on an effective device.

    Science.gov (United States)

    Li, Wei; Zhang, Xuan; Tong, Peijin; Wu, Ting; Hu, Huilian; Wang, Meng; Du, Yiping

    2014-04-24

    A novel, rapid, simple, and low-cost on-line determination approach of dispersive liquid-liquid microextraction (DLLME) with low-density solvents was developed with the support of a specially designed effective homemade device. The proposed method surmounted the drawbacks of conventional DLLME of the need of high-density solvents as extractants, and the requirement of centrifugation operation to obtain phase separation, and the difficulties to realize on-line determination. The amount of sample utilized can conveniently change according to practical needs by varying the volume of the extraction tube of the device to perform a more effective DLLME. A case study was carried out to assess this method utilizing the dye rhodamine B as the model analyte. The experiment parameters influencing the extraction were systematically investigated. Under optimum conditions, the linearity was obtained in the range of 0.015-1.000 μg/mL with the correlation coefficient (r(2)) of 0.9980. The limit of detection and quantification were 6.1 and 20.4 μg/L, respectively. Good repeatability was achieved with the relative standard deviations (RSD) for five replicate measurements of different concentration samples less than 4.06%, and the presented method was successfully employed to quantify rhodamine B in three real samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. A high-throughput liquid chromatography/tandem mass spectrometry method for simultaneous quantification of a hydrophobic drug candidate and its hydrophilic metabolite in human urine with a fully automated liquid/liquid extraction.

    Science.gov (United States)

    Wang, Perry G; Zhang, Jun; Gage, Eric M; Schmidt, Jeffrey M; Rodila, Ramona C; Ji, Qin C; El-Shourbagy, Tawakol A

    2006-01-01

    ABT-869 (A-741439) is an investigational new drug candidate under development by Abbott Laboratories. ABT-869 is hydrophobic, but is oxidized in the body to A-849529, a hydrophilic metabolite that includes both carboxyl and amino groups. Poor solubility of ABT-869 in aqueous matrix causes simultaneous analysis of both ABT-869 and its metabolite within the same extraction and injection to be extremely difficult in human urine. In this paper, a high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method has been developed and validated for high-speed simultaneous quantitation of the hydrophobic ABT-869 and its hydrophilic metabolite, A-849529, in human urine. The deuterated internal standards, A-741439D(4) and A-849529D(4), were used in this method. The disparate properties of the two analytes were mediated by treating samples with acetonitrile, adjusting pH with an extraction buffer, and optimizing the extraction solvent and mobile phase composition. For a 100 microL urine sample volume, the lower limit of quantitation was approximately 1 ng/mL for both ABT-869 and A-849529. The calibration curve was linear from 1.09 to 595.13 ng/mL for ABT-869, and 1.10 to 600.48 ng/mL for A-849529 (r2 > 0.9975 for both ABT-869 and A-849529). Because the method employs simultaneous quantification, high throughput is achieved despite the presence of both a hydrophobic analyte and its hydrophilic metabolite in human urine. Copyright 2006 John Wiley & Sons, Ltd.

  3. Feasibility and application of liquid-liquid extraction combined with gas chromatography-mass spectrometry for the analysis of phenolic acids from grape polyphenols degraded by human faecal microbiota.

    Science.gov (United States)

    Muñoz-González, C; Moreno-Arribas, M V; Rodríguez-Bencomo, J J; Cueva, C; Martín Álvarez, P J; Bartolomé, B; Pozo-Bayón, M A

    2012-07-15

    In this study the feasibility of a LLE-GC-EI-MS method for the analysis of 43 phenolic acids belonging to different chemical structure families which have been described in the literature as microbial-derived metabolites after consumption of dietary polyphenols was proved. In addition, the method was applied for the characterisation of phenolic metabolites resulting from the incubation, in anaerobic conditions, of a commercial grape seed extract (GSE) and their corresponding flavan-3-ol monomeric (GSE-M) and oligomeric (GSE-O) fractions with human faeces from healthy volunteers (n=3). The method showed average values of repeatability and reproducibility of 5.0% and 6.3%, respectively, adequate and low detection (1.8-30.8 μg L(-1)) and quantification limits (6.0-102.8 μg L(-1)) and good recovery values (95%, as average value). A total of 27 phenolic acids were identified in the faecal solutions after incubation with the grape seed extracts. In general, faecal samples incubated with GSE and GSE-M (monomeric fraction) yield a higher formation of phenolic acids compared to the samples incubated with the oligomer fraction (GSE-O). Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Drop coalescence through a liquid/liquid interface

    Science.gov (United States)

    Mohamed-Kassim, Zulfaa; Longmire, Ellen K.

    2004-07-01

    Particle image velocimetry (PIV) experiments were conducted to study the coalescence of single drops through planar liquid/liquid interfaces. Sequences of velocity vector fields were obtained with a high-speed video camera and subsequent PIV analysis. Two ambient liquids with different viscosity but similar density were examined resulting in Reynolds numbers based on a surface tension velocity of 10 and 26. Prior to rupture, the drops rested on a thin film of ambient liquid above an underlying interface. After rupture, which was typically off-axis, the free edge of the thin film receded rapidly allowing the drop fluid to sink into the bulk liquid below. Vorticity generated in the collapsing fluid developed into a vortex ring straddling the upper drop surface. The ring core traveled radially inward with a ring-shaped capillary wave effectively pinching the upper drop surface and increasing the drop collapse speed. The inertia of the collapse deflected the interface downward before it rebounded upward. During this time, the vortex core split so that part of its initial vorticity moved inside the drop fluid while part remained in the ambient fluid above it. A second ring-shaped capillary wave formed along the interface outside of the drop and propagated radially outward during the collapse. Changing the ambient fluid viscosity resulted in several effects. First, the velocity of the receding free edge was smaller for higher ambient viscosity. Second, the pinching of the upper drop surface caused by the shrinking capillary ring wave was stronger when the ambient viscosity was lower, and this resulted in a higher maximum collapse speed and higher vorticity values in the dominant vortex ring.

  5. Extração líquido-líquido de ferro(III e titânio(IV pelo ácido bis-(2-etil-hexil fosfórico (D2EHPA em meio de ácido sulfúrico Liquid-liquid extraction (LLE of Fe(III and Ti(IV by bis-(2-ethyl-hexyl phosphoric acid (D2EHPA in sulfuric acid medium

    Directory of Open Access Journals (Sweden)

    Glauco Corrêa da Silva

    2008-01-01

    Full Text Available This work presents a study on the separation of Fe(III and Ti(IV from sulfuric acid leaching solutions of ilmenite (FeTiO3 using liquid-liquid extraction with D2EHPA in n-dodecane as extracting agent. The distribution coefficients (K D of the elements related to free acidity and concentration of Fe(III and Ti(IV were determined. Free acidity was changed from 3x10-2 to 11.88 mol L-1 and D2EHPA concentration was fixed at 1.5 mol L-1. Recovery of final products as well as recycling of wastes generated in the process were also investigated. The LLE process as a feasible alternative to obtain high-purity TiO2.

  6. Development of two step liquid-liquid extraction tandem UHPLC-MS/MS method for the simultaneous determination of Ginkgo flavonoids, terpene lactones and nimodipine in rat plasma: Application to the pharmacokinetic study of the combination of Ginkgo biloba dispersible tablets and Nimodipine tablets.

    Science.gov (United States)

    Xiao, Jie; Wang, Tianyang; Li, Pei; Liu, Ran; Li, Qing; Bi, Kaishun

    2016-08-15

    A sensitive, reliable and accurate UHPLC-MS/MS method has been firstly established and validated for the simultaneous quantification of ginkgo flavonoids, terpene lactones and nimodipine in rat plasma after oral administration of Ginkgo biloba dispersible tablets, Nimodipine tablets and the combination of the both, respectively. The plasma samples were extracted by two step liquid-liquid extraction, nimodipine was extracted by hexane-ether (3:1, v/v) at the first step, after that ginkgo flavonoids and terpene lactones were extracted by ethyl acetate. Then the analytes were successfully separated by running gradient elution with the mobile phase consisting of 0.1% formic acid in water and methanol at a flow rate of 0.6mL/min. The detection of the analytes was performed on a UHPLC-MS/MS system with turbo ion spray source in the negative ion and multiple reaction monitoring (MRM) mode. The calibration curves for the determination of all the analytes showed good linearity (R(2)>0.99), and the lower limits of quantification were 0.50-4.00ng/mL. Intra-day and inter-day precisions were in the range of 3.6%-9.2% and 3.2%-13.1% for all the analytes. The mean extraction recoveries of the analytes were within 69.82%-103.5% and the matrix were within 82.8%-110.0%. The validated method had been successfully applied to compare the pharmacokinetic parameters of ginkgo flavonoids, terpene lactones and nimodipine in rat plasma after oral administration of Ginkgo biloba dispersible tablets, Nimodipine tablets with the combination of the both. There were no statistically significant differences on the pharmacokinetic behaviors of all the analytes between the combined and single administration groups. Results showed that the combination of the two agents may avoid dosage adjustments in clinic and the combination is more convenient as well as efficient on different pathogenesis of cerebral ischemia. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Liquid-liquid interfacial tension of electrolyte solutions

    NARCIS (Netherlands)

    Bier, Markus; Zwanikken, J.W.; van Roij, R.H.H.G.

    2008-01-01

    It is theoretically shown that the excess liquid-liquid interfacial tension between two electrolyte solutions as a function of the ionic strength I behaves asymptotically as (-) for small I and as (±I) for large I. The former regime is dominated by the electrostatic potential due to an unequal

  8. Redox-active Crosslinkable Poly(ionic liquid)s

    NARCIS (Netherlands)

    Sui, Xiaofeng; Hempenius, Mark A.; Vancso, Gyula J.

    2012-01-01

    The synthesis of a new class of cross-linkable redox-responsive poly(ferrocenylsilane)-based poly(ionic liquid)s (PFS-PILs) is reported. PFS-PILs self-cross-link at low concentrations into nanogels or form macroscopic hydrogel networks at higher concentrations. PFS-PILs proved to be efficient

  9. Diazepam e nordiazepam em plasma: métodos de extração líquido-líquido e em fase sólida no pré-tratamento de amostras para análise cromatográfica em fase líquida Diazepam and nordiazepam in plasma: liquid-liquid and solid phase extraction in sample pre-treatment for high performance liquid chromatography analysis

    Directory of Open Access Journals (Sweden)

    Ellen Figueiredo Freire

    2005-10-01

    Full Text Available Analysis of diazepam (DZP and its active metabolite nordiazepam (NDZP in plasma is commonly performed in clinical medicine to ensure proper therapeutic effects while minimizing the incidence of toxicity. This study aimed to optimize analytical parameters and compare two pre-treatment techniques, liquid-liquid (LLE and solid phase extraction (SPE, as well as liquid chromatographic conditions to analyze simultaneously DZP and NDZP in plasma from 20 patients treated with a daily dose of 10 mg. Both techniques showed to be well in line with the international criteria for analytical validation, which permitted to quantify DZP (66.2 - 1148.6 ng mL-1 and NDZP (138.5 - 808.6 ng mL -1 in all samples. The correlation coefficients between SPE and LLE were respectively 0.9729 for DZP and 0.9643 for NDZP.

  10. Vortex-assisted low density solvent based demulsified dispersive liquid-liquid microextraction and high-performance liquid chromatography for the determination of organophosphorus pesticides in water samples.

    Science.gov (United States)

    Seebunrueng, Ketsarin; Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2014-05-01

    A simple, rapid, effective and eco-friendly preconcentration method, vortex-assisted low density solvent based solvent demulsified dispersive liquid-liquid microextraction (VLDS-SD-DLLME), followed by high performance liquid chromatography-diode array detector (HPLC-DAD) analysis, has been developed for the first time for the determination of four organophosphorus pesticides (OPPs) (e.g., azinphos-methyl, parathion-methyl, fenitrothion and diazinon) in environmental water samples. In this preconcentration procedure, an emulsion was obtained after the mixture of extraction solvent (1-dodecanol) and dispersive solvent (acetonitrile, ACN) was injected rapidly into 10 mL of the sample solution. The vortex agitator aided the dispersion of the extraction solvent into the sample solution. After the formation of an emulsion, the demulsifier (ACN) was added, resulting in the rapid separation of the mixture into two phases without centrifugation. Under optimal conditions, the proposed method provided high extraction efficiency (90-99%), good linearity range (0.5-500 ng mL(-1)), low limits of detection (0.25-1 ng mL(-1)) and good repeatability and recoveries were obtained. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Engineering adhesion to thermoresponsive substrates: effect of polymer composition on liquid-liquid-solid wetting.

    Science.gov (United States)

    Gambinossi, Filippo; Sefcik, Lauren S; Wischerhoff, Erik; Laschewsky, Andre; Ferri, James K

    2015-02-04

    Adhesion control in liquid-liquid-solid systems represents a challenge for applications ranging from self-cleaning to biocompatibility of engineered materials. By using responsive polymer chemistry and molecular self-assembly, adhesion at solid/liquid interfaces can be achieved and modulated by external stimuli. Here, we utilize thermosensitive polymeric materials based on random copolymers of di(ethylene glycol) methyl ether methacrylate (x = MEO2MA) and oligo(ethylene glycol) methyl ether methacrylate (y = OEGMA), that is, P(MEO2MAx-co-OEGMAy), to investigate the role of hydrophobicity on the phenomenon of adhesion. The copolymer ratio (x/y) dictates macromolecular changes enabling control of the hydrophilic-to-lipophilic balance (HBL) of the polymer brushes through external triggers such as ionic strength and temperature. We discuss the HBL of the thermobrushes in terms of the surface energy of the substrate by measuring the contact angle at water-decane-P(MEO2MAx-co-OEGMAy) brush contact line as a function of polymer composition and temperature. Solid supported polyelectrolyte layers grafted with P(MEO2MAx-co-OEGMAy) display a transition in the wettability that is related to the lower critical solution temperature of the polymer brushes. Using experimental observation of the hydrophilic to hydrophobic transition by the contact angle, we extract the underlying energetics associated with liquid-liquid-solid adhesion as a function of the copolymer ratio. The change in cellular attachment on P(MEO2MAx-co-OEGMAy) substrates of variable (x/y) composition demonstrates the subtle role of compositional tuning on the ability to control liquid-liquid-solid adhesion in biological applications.

  12. Energy conversion at liquid/liquid interfaces: artificial photosynthetic systems

    Science.gov (United States)

    Volkov, A. G.; Gugeshashvili, M. I.; Deamer, D. W.

    1995-01-01

    This chapter focuses on multielectron reactions in organized assemblies of molecules at the liquid/liquid interface. We describe the thermodynamic and kinetic parameters of such reactions, including the structure of the reaction centers, charge movement along the electron transfer pathways, and the role of electric double layers in artificial photosynthesis. Some examples of artificial photosynthesis at the oil/water interface are considered, including water photooxidation to the molecular oxygen, oxygen photoreduction, photosynthesis of amphiphilic compounds and proton evolution by photochemical processes.

  13. Rapid Column Extraction method for SoilRapid Column Extraction method for Soil

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod, L. III; Culligan, Brian K.

    2005-11-07

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring as well as for emergency preparedness. A new, rapid actinide separation method has been developed and implemented that provides total dissolution of large soil samples, high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu) neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alpha spectrometry. The method combines a rapid fusion step for total dissolution to dissolve refractory analytes and matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  14. Rapid Statistical Learning Supporting Word Extraction From Continuous Speech.

    Science.gov (United States)

    Batterink, Laura J

    2017-07-01

    The identification of words in continuous speech, known as speech segmentation, is a critical early step in language acquisition. This process is partially supported by statistical learning, the ability to extract patterns from the environment. Given that speech segmentation represents a potential bottleneck for language acquisition, patterns in speech may be extracted very rapidly, without extensive exposure. This hypothesis was examined by exposing participants to continuous speech streams composed of novel repeating nonsense words. Learning was measured on-line using a reaction time task. After merely one exposure to an embedded novel word, learners demonstrated significant learning effects, as revealed by faster responses to predictable than to unpredictable syllables. These results demonstrate that learners gained sensitivity to the statistical structure of unfamiliar speech on a very rapid timescale. This ability may play an essential role in early stages of language acquisition, allowing learners to rapidly identify word candidates and "break in" to an unfamiliar language.

  15. Optimization of dispersive liquid-liquid microextraction for the selective determination of trace amounts of palladium by flame atomic absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kokya, Taher Ahmadzadeh [Department of Chemistry, Faculty of Science, University of Urmia, Urmia (Iran, Islamic Republic of); Farhadi, Khalil, E-mail: khalil.farhadi@yahoo.com [Department of Chemistry, Faculty of Science, University of Urmia, Urmia (Iran, Islamic Republic of)

    2009-09-30

    A new simple and reliable method for rapid and selective extraction and determination of the trace levels of Pd{sup 2+} ion was developed by dispersive liquid-liquid microextraction preconcentration and flame atomic absorption spectrometry detection. In the proposed approach, thioridazine HCl (TRH) was used as a Pd{sup 2+} ion selective complexing agent. The effective parameters on the extraction recovery were studied and optimized utilizing two decent optimization methods; factorial design and central composite design (CCD). Through factorial design the best efficiency of extraction acquired using ethanol and chloroform as dispersive and extraction solvents respectively. CCD optimization resulted in 1.50 mL of dispersive solvent; 0.15 mL of extraction solvent; 0.45 mg of TRH and 250 mg of potassium chloride salt per 5 mL of sample solution. Under the optimum conditions the calibration graph was linear over the range 100-2000 {mu}g L{sup -1}. The average relative standard deviation was 0.7% for five repeated determinations. The limit of detection was 90 {mu}g L{sup -1}. The average enrichment factor and recovery reached 45.7% and 74.2% respectively. The method was successfully applied to the determination of trace amounts of palladium in the real water samples.

  16. (Liquid + liquid) equilibria of (water + ethanol + dimethyl glutarate) at several temperatures[(Liquid+liquid) equilibria; Ethanol; Dimethyl glutarate; UNIFAC method

    Energy Technology Data Exchange (ETDEWEB)

    Ince, Erol. E-mail: erolince@istanbul.edu.tr; Kirbaslar, S. Ismail. E-mail: krbaslar@istanbul.edu.tr

    2003-10-01

    (Liquid + liquid) equilibrium (LLE) data of (water + ethanol + dimethyl glutarate) have been determined experimentally at T=(298.15,308.15 and 318.15) K. The reliability of the experimental tie-line data was ascertained by using the Othmer and Tobias correlation. The LLE data of the ternary mixture were predicted by UNIFAC method. Distribution coefficients and separation factors were evaluated for the immiscibility region.

  17. A rapid DNA extraction method suitable for human papillomavirus detection.

    Science.gov (United States)

    Brestovac, Brian; Wong, Michelle E; Costantino, Paul S; Groth, David

    2014-04-01

    Infection with oncogenic human papillomavirus (HPV) genotypes is necessary for the development of cervical cancer. Testing for HPV DNA from liquid based cervical samples can be used as an adjunct to traditional cytological screening. In addition there are ongoing viral load, genotyping, and prevalence studies. Therefore, a sensitive DNA extraction method is needed to maximize the efficiency of HPV DNA detection. The XytXtract Tissue kit is a DNA extraction kit that is rapid and so could be useful for HPV testing, particularly in screening protocols. This study was undertaken to determine the suitability of this method for HPV detection. DNA extraction from HeLa and Caski cell lines containing HPV 18 and 16 respectively together with DNA from five liquid based cervical samples were used in a HPV PCR assay. DNA was also extracted using the QIAamp DNA mini kit (Qiagen, Hilden, Germany) as a comparison. DNA extracts were serially diluted and assayed. HPV DNA was successfully detected in cell lines and cervical samples using the XytXtract Tissue kit. In addition, the XytXtract method was found to be more sensitive than the QIAmp method as determined by a dilution series of the extracted DNA. While the XytXtract method is a closed, the QIAamp method uses a spin column with possible loss of DNA through DNA binding competition of the matrix, which could impact on the final extraction efficiency. The XytXtract is a cheap, rapid and efficient method for extracting HPV DNA from both cell lines and liquid based cervical samples. © 2014 Wiley Periodicals, Inc.

  18. Rapid extraction of aflatoxin from creamy and crunchy peanut butter.

    Science.gov (United States)

    Vega, Victor A

    2005-01-01

    A rapid extraction technique was developed for the isolation and subsequent liquid chromatographic determination of aflatoxins B1, B2, G1, and G2 in creamy and crunchy peanut butter. Peanut buftter samples were extracted with a methanol 15% sodium chloride (7 + 3) solution followed by a second extraction with methanol. The extract was subjected to a cleanup using a Vicam Aflatest immunoaffinity column. Control samples for both smooth and crunchy peanut butter were fortified at 4 different levels for aflatoxin B1, B2, G1, and G2. The average aflatoxin B1, B2, G1, and G2 recoveries from smooth peanut buffer were 95.2, 89.9, 94.1, and 62.4%, respectively, and 92.4, 84.3, 85.5, and 53.7%, respectively, from crunchy peanut butter. This extraction method and the official AOAC Method 991.31 produced comparable results for peanut butter samples. This method provides a rapid, specific, and easily controlled assay for the analysis of aflatoxins in peanut butter with minimal solvent usage. Organic solvent consumption was decreased by 85% and hazardous waste production was decreased by 80% in comparison with the AOAC method. Along with the decreased solvent consumption, significant savings in time were observed.

  19. Rapid automatic keyword extraction for information retrieval and analysis

    Science.gov (United States)

    Rose, Stuart J [Richland, WA; Cowley,; E, Wendy [Richland, WA; Crow, Vernon L [Richland, WA; Cramer, Nicholas O [Richland, WA

    2012-03-06

    Methods and systems for rapid automatic keyword extraction for information retrieval and analysis. Embodiments can include parsing words in an individual document by delimiters, stop words, or both in order to identify candidate keywords. Word scores for each word within the candidate keywords are then calculated based on a function of co-occurrence degree, co-occurrence frequency, or both. Based on a function of the word scores for words within the candidate keyword, a keyword score is calculated for each of the candidate keywords. A portion of the candidate keywords are then extracted as keywords based, at least in part, on the candidate keywords having the highest keyword scores.

  20. Comparison of ultrasound-enhanced air-assisted liquid-liquid microextraction and low-density solvent-based dispersive liquid-liquid microextraction methods for determination of nonsteroidal anti-inflammatory drugs in human urine samples.

    Science.gov (United States)

    Barfi, Behruz; Asghari, Alireza; Rajabi, Maryam; Goochani Moghadam, Ahmad; Mirkhani, Nasim; Ahmadi, Farhad

    2015-01-01

    Two dispersive-based liquid-liquid microextraction methods including ultrasound-enhanced air-assisted liquid-liquid microextraction (USE-AALLME) and low-density solvent-based dispersive liquid-liquid microextraction (LDS-DLLME) were compared for the extraction of salicylic acid (the hydrolysis product of acetylsalicylic acid), diclofenac and ibuprofen, as instances of the most commonly used nonsteroidal anti-inflammatory drugs (NSAIDs), in human urine prior to their determination by gas chromatography with flame ionization detection (GC-FID). The influence of different parameters affecting the USE-AALLME (including type and volume of the extraction solvent, sample pH, ionic strength, and simultaneous sonication and number of extraction cycles) and the LDS-DLLME (including type and volume of the extraction and disperser solvents, sample pH, and ionic strength) were investigated to optimize their extraction efficiencies. Both methods are fast, simple and convenient with organic solvent consumption at μL level. However, the best results were obtained using the USE-AALLME method, applying 30 μL of 1-octanol as extraction solvent, 5.0 mL of sample at pH 3.0, without salt addition, and 5 extraction cycles during 20s of sonication. This method was validated based on linearities (r(2) >0 .971), limits of detection (0.1-1.0 μg L(-1)), linear dynamic ranges (0.4-1000.0 μg L(-1)), enrichment factors (115 ± 3-135 ± 3), consumptive indices (0.043-0.037), inter- and intra-day precisions (4.3-4.8 and 5.6-6.1, respectively), and relative recoveries (94-103%). The USE-AALLME in combination with GC-FID, and with no need to derivatization step, was demonstrated to be a simple, inexpensive, sensitive and efficient method to determine NSAIDs in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Vortex-assisted liquid-liquid microextraction combined with gas chromatography-mass spectrometry for the determination of organophosphate pesticides in environmental water samples and wines.

    Science.gov (United States)

    Zacharis, Constantinos K; Christophoridis, Christophoros; Fytianos, Konstantinos

    2012-09-01

    A simple vortex-assisted liquid-liquid microextraction protocol followed by GC-MS is proposed for the determination of 12 organophosphate pesticides residues in environmental water samples and wines. The sample pretreatment employs the usage of low-density organic solvent. The parameters affecting the extraction efficiency (type and volume of organic extraction solvent, sample pH, ionic strength, extraction time, and centrifugation speed) were carefully examined. A mild emulsification process was involved by the addition of 40 μL toluene into 10 mL sample followed by sequential vortex-based agitation and manual shaking for 3 min. Following the extraction, the pesticide-rich organic solvent was recovered by centrifugation at 4000 rpm for 5 min. A fraction of the floated toluene was then collected and analyzed by GC-MS in SIM mode. Under the optimized conditions, the enrichment factor ranged between 65 and 389. Satisfactory linearity was observed for all pesticides tested with correlation coefficients higher than 0.9945 while the LODs were in the range of 2-11 ng L(-1) . The main advantages of the proposed method are the simplicity of operation, rapidity, low cost, and high sensitivity. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. SPE coupled with dispersive liquid-liquid microextraction followed by GC with flame ionization detection for the determination of ultra-trace amounts of benzodiazepines.

    Science.gov (United States)

    Ghobadi, Masoomeh; Yamini, Yadollah; Ebrahimpour, Behnam

    2014-02-01

    SPE combined with dispersive liquid-liquid microextration was used for the extraction of ultra-trace amounts of benzodiazepines (BZPs) including, diazepam, midazolam, and alprazolam, from ultra-pure water, tap water, fruit juices, and urine samples. The analytes were adsorbed from large volume samples (60 mL) onto octadecyl silica SPE columns. After the elution of the desired compounds from sorbents with 2.0 mL acetone, 0.5 mL of eluent containing 40.0 μL chloroform was injected rapidly into 4.5 mL pure water. After extraction and centrifugation, 2 μL of the sedimented phase was injected into a GC equipped with a flame ionization detector. Several parameters affecting this process were investigated and optimized. Under the optimal conditions, LODs ranged from 0.02 to 0.05 μg/L, a linear dynamic range of 0.1-100 μg/L and relative SDs in the range of 4.4-10.7% were attained. Very high preconcentration factors ranging from 3895-7222 were achieved. The applicability of the method for the extraction of BZPs from different types of complicated matrices, such as tap water, fruit juices, and urine samples, was studied. The obtained results reveal that the proposed method is a good technique for the extraction and determination of BZPs in complex matrices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. The application of dispersive liquid-liquid microextraction in the analyses of the fatty acid profile in bovine milk in response to changes in body condition score.

    Science.gov (United States)

    Quigley, Andrew; Connolly, Damian; Cummins, Wayne

    2018-01-15

    Dispersive liquid-liquid microextraction (DLLME) was used prior to gas chromatography flame ionization detection (GC-FID) for the extraction of five fatty acids from milk taken from cows with different body condition scores. Optimum extraction conditions were: 300 μL of chloroform (extraction solvent), and 1 mL methanol (dispersive solvent). The procedure was optimised using Design of Experiments (DoE). The analytes were separated on a GC capillary column containing a polyethylene glycol stationary phase (15 m × 0.53 mm × 1.2 μm). Enrichment factors were in the range of 8-15 and limit of detection (LOD) was 0.04 μg/mL. Calibration graphs showed good linearity with coefficients of determination higher than 0.994% and relative standard deviations lower than 7%. This method provided a simple and rapid derivatisation and extraction method for the determination of fatty acids in bovine milk. It showed that there was a significant difference in the palmitic acid content of milk from cows that had an optimum body condition score (10.85 mg/mL) compared to cows that had a high body condition score (5.73 mg/mL). Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Preparing Silica Aerogel Monoliths via a Rapid Supercritical Extraction Method

    Science.gov (United States)

    Gorka, Caroline A.

    2014-01-01

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10-3 molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes. PMID:24637334

  5. Ionic liquid ultrasound assisted dispersive liquid-liquid microextraction method for preconcentration of trace amounts of rhodium prior to flame atomic absorption spectrometry determination

    Energy Technology Data Exchange (ETDEWEB)

    Molaakbari, Elaheh [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Young Research Society, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Mostafavi, Ali, E-mail: mostafavi.ali@gmail.com [Chemistry Department, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Afzali, Daryoush [Environment and Nanochemistry Department, Research Institute of Environmental Science, International Center for Science, High Technology and Environmental Science, Kerman (Iran, Islamic Republic of); Mineral Industries Research Center, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2011-01-30

    In this article, we consider ionic liquid based ultrasound-assisted dispersive liquid-liquid microextraction of trace amounts of rhodium from aqueous samples and show that this is a fast and reliable sample pre-treatment for the determination of rhodium ions by flame atomic absorption spectrometry. The Rh(III) was transferred into its complex with 2-(5-bromo-2-pyridylazo)-5-diethylamino phenol as a chelating agent, and an ultrasonic bath with the ionic liquid, 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide at room temperature was used to extract the analyte. The centrifuged rhodium complex was then enriched in the form of ionic liquid droplets and prior to its analysis by flame atomic absorption spectrometry, 300 {mu}L ethanol was added to the ionic liquid-rich phase. Finally, the influence of various parameters on the recovery of Rh(III) was optimized. Under optimum conditions, the calibration graph was linear in the range of 4.0-500.0 ng mL{sup -1}, the detection limit was 0.37 ng mL{sup -1} (3S{sub b}/m, n = 7) and the relative standard deviation was {+-}1.63% (n = 7, C = 200 ng mL{sup -1}). The results show that ionic liquid based ultrasound assisted dispersive liquid-liquid microextraction, combined with flame atomic absorption spectrometry, is a rapid, simple, sensitive and efficient analytical method for the separation and determination of trace amounts of Rh(III) ions with minimum organic solvent consumption.

  6. Rapid extraction and assay of uranium from environmental surface samples

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.; Olsen, Khris B.; Addleman, Raymond Shane

    2017-10-01

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonate and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.

  7. Liquid-liquid equilibria for ternary polymer mixtures

    Science.gov (United States)

    Oh, Suk Yung; Bae, Young Chan

    2011-01-01

    A molecular thermodynamic model for multicomponent systems based on a closed-packed lattice model is presented based on two contributions; entropy and energy contribution. The calculated liquid-liquid equilibria of ternary chainlike mixtures agreed with Monte Carlo simulation results. The proposed model can satisfactorily predict Types 0, 1, 2 and 3 phase separations of the Treybal classification. The model parameters obtained from the binary systems were used to directly predict real ternary systems and the calculated results correlated well with experimental data using few adjustable parameters. Specific interactions in associated binary systems were considered using a secondary lattice.

  8. Speciation analysis of mercury in water samples by dispersive liquid-liquid microextraction coupled to capillary electrophoresis.

    Science.gov (United States)

    Yang, Fangfang; Li, Jinhua; Lu, Wenhui; Wen, Yingying; Cai, Xiaoqiang; You, Jinmao; Ma, Jiping; Ding, Yangjun; Chen, Lingxin

    2014-02-01

    In this study, a method of pretreatment and speciation analysis of mercury by dispersive liquid-liquid microextraction along with CE was developed. The method was based on the fact that mercury species including methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and Hg(II) were complexed with 1-(2-pyridylazo)-2-naphthol to form hydrophobic chelates and l-cysteine could displace 1-(2-pyridylazo)-2-naphthol to form hydrophilic chelates with the four mercury species. Factors affecting complex formation and extraction efficiency, such as pH value, type, and volume of extractive solvent and disperser solvent, concentration of the chelating agent, ultrasonic time, and buffer solution were investigated. Under the optimal conditions, the enrichment factors were 102, 118, 547, and 46, and the LODs were 1.79, 1.62, 0.23, and 1.50 μg/L for MeHg, EtHg, PhHg, and Hg(II), respectively. Method precisions (RSD, n = 5) were in the range of 0.29-0.54% for migration time, and 3.08-7.80% for peak area. Satisfactory recoveries ranging from 82.38 to 98.76% were obtained with seawater, lake, and tap water samples spiked at three concentration levels, respectively, with RSD (n = 5) of 1.98-7.18%. This method was demonstrated to be simple, convenient, rapid, cost-effective, and environmentally benign, and could be used as an ideal alternative to existing methods for analyzing trace residues of mercury species in water samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Dispersive liquid-liquid microextraction combined with non-aqueous capillary electrophoresis for the determination of imazalil, prochloraz and thiabendazole in apples, cherry tomatoes and grape juice.

    Science.gov (United States)

    Xu, Lina; Luan, Feng; Liu, Huitao; Gao, Yuan

    2015-03-15

    Fruit and vegetables are frequently treated with fungicides to reduce possible spoilage. As a result, fungicide residues may be accumulated in derived products. This important group of chemical compounds has been heavily regulated because of their potential toxicity. Therefore, a simple and rapid method to determine fungicides is desired. A simple non-aqueous capillary electrophoresis (NACE) method based on dispersive liquid-liquid microextraction (DLLME) has been proposed for the determination of imazalil, prochloraz and thiabendazole fungicides in fruits and juice samples. Separation buffer consisted of a methanol-acetonitrile mixture (35:65, v/v) containing 30 mmol L⁻¹ ammonium chloride and 0.5% phosphoric acid. The optimum DLLME conditions were 80 µL trichloromethane as extraction solvent, 0.5 mL tetrahydrofuran as disperser solvent, sample solution pH at 6.0, 5% (w/v) NaCl and 10 s extraction time. Recoveries obtained for various samples ranged from 72% to 102%, with relative standard deviation lower than 6.4%. The limits of detection ranged from 0.47 to 0.72 µg kg⁻¹. The proposed method takes the advantages of DLLME and NACE. It is rapid, accurate, sensitive and reproducible for the determination of imazalil, prochloraz and thiabendazole in fruit samples. © 2014 Society of Chemical Industry.

  10. Intramolecular coupling as a mechanism for a liquid-liquid phase transition

    OpenAIRE

    Franzese, Giancarlo; Marqués, Manuel I.; Stanley, H. Eugene

    2003-01-01

    We study a model for water with a tunable intramolecular interaction Js, using mean-field theory and off-lattice Monte Carlo simulations. For all Js>~0, the model displays a temperature of maximum density. For a finite intramolecular interaction Js>0, our calculations support the presence of a liquid-liquid phase transition with a possible liquid-liquid critical point for water, likely preempted by inevitable freezing. For J=0, the liquid-liquid critical point disappears at T=0.

  11. Hollow-Fibre-Supported Dispersive Liquid-Liquid Microextraction for Determination of Atrazine and Triclosan in Aqueous Samples

    OpenAIRE

    Letseka, Thabiso; George, Mosotho J.

    2017-01-01

    We report the application of the dispersive liquid-liquid microextraction coupled to hollow-fibre membrane-assisted liquid-phase microextraction and its application for extraction of atrazine and triclosan. Under optimum conditions, namely, 25 μL of a 1 : 4 chlorobenzene : ethyl acetate mixture dispersed in 1 mL of aqueous sample, 10% (m/v) NaCl, a magnetic stirrer speed at 600 rpm, and 10 minutes' extraction time with toluene-filled fibre as the acceptor phase, the method demonstrates suffic...

  12. Determination of amantadine in biological fluids using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Nouri, Nina; Alizadeh Nabil, Ali Akbar

    2013-12-01

    A one-step derivatization and microextraction technique for the determination of amantadine in the human plasma and urine samples is presented. An appropriate mixture of methanol (disperser solvent), 1,2-dibromoethane (extraction solvent), and butylchloroformate (derivatization agent) is rapidly injected into samples. After centrifuging, the sedimented phase is analyzed by gas chromatography-flame ionization detection (GC-FID). The kind of extraction and disperser solvents and their volumes, amount of derivatization agent and reaction/extraction time which are effective in derivatization/dispersive liquid-liquid microextraction (DLLME) procedure are optimized. Under the optimal conditions, the enrichment factor (EF) of the target analyte was obtained to be 408 and 420, and limit of detection (LOD) 4.2 and 2.7ngmL(-1), in plasma and urine respectively. The linear range is 14-5000 and 8.7-5000ng/mL for plasma and urine, respectively (squared correlation coefficient≥0.990). The relative recoveries obtained for the spiked plasma and urine samples are between 72% and 93%. Moreover, the inter- and intra-day precisions are acceptable at all spiked concentrations (relative standard deviation amantadine in biological samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Dispersive liquid-liquid microextraction based on solidification of floating organic drop for preconcentration and determination of trace amounts of copper by flame atomic absorption spectrometry.

    Science.gov (United States)

    Karadaş, Cennet; Kara, Derya

    2017-04-01

    A novel, simple, rapid, sensitive, inexpensive and environmentally friendly dispersive liquid-liquid microextraction method based on the solidification of a floating organic drop (DLLME-SFO) was developed for the determination of copper by flame atomic absorption spectrometry (FAAS). N-o-Vanillidine-2-amino-p-cresol was used as a chelating ligand and 1-undecanol was selected as an extraction solvent. The main parameters affecting the performance of DLLME-SFO, such as sample pH, volume of extraction solvent, extraction time, concentration of the chelating ligand, salt effect, centrifugation time and sample volume were investigated and optimized. The effect of interfering ions on the recovery of copper was also examined. Under the optimum conditions, the detection limit (3σ) was 0.93μgL(-1) for Cu using a sample volume of 20mL, yielding a preconcentration factor of 20. The proposed method was successfully applied to the determination of Cu in tap, river and seawater, rice flour and black tea samples as well as certified reference materials. Copyright © 2016. Published by Elsevier Ltd.

  14. Spectroscopic analysis of bosentan in biological samples after a liquid-liquid microextraction

    Directory of Open Access Journals (Sweden)

    Sanaz Sajedi-Amin

    2015-12-01

    Conclusion: A simple, low cost, precise and accurate spectrophotometric analysis of bosentan in biological samples after liquid-liquid microextraction were developed and validated for routine analyses.

  15. Quaternary liquid-liquid equilibrium studies on hydrocarbon-solvent systems

    Energy Technology Data Exchange (ETDEWEB)

    Naithani, J.; Khanna, M.K.; Nanoti, S.M.; Rawat, B.S. (Indian Inst. of Petroleum, Dehra Dun 248005 (IN))

    1992-01-01

    This paper reports that quaternary equilibrium tie-line data have been determined at 60{degrees}C for the model hydrocarbon mixtures of naphtha and kerosene with sulfolane and triethylene glycol solvents. The study was carried out in order to understand the mechanism of simultaneous extraction of aromatics from naphtha and kerosene feedstocks. Benzene-heptane and 1-methylnaphthalene-dodecane model mixtures were chosen as feeds representing naphtha and kerosene cuts, respectively. The liquid-liquid equilibrium data so obtained have been predicted by the UNIFAC group contribution model. Group interaction parameters for groups which best represent triethylene glycol molecule were also calculated from the data available with the authors for those not available in the literature.

  16. Rapid extraction and preservation of genomic DNA from human samples.

    Science.gov (United States)

    Kalyanasundaram, D; Kim, J-H; Yeo, W-H; Oh, K; Lee, K-H; Kim, M-H; Ryew, S-M; Ahn, S-G; Gao, D; Cangelosi, G A; Chung, J-H

    2013-02-01

    Simple and rapid extraction of human genomic DNA remains a bottleneck for genome analysis and disease diagnosis. Current methods using microfilters require cumbersome, multiple handling steps in part because salt conditions must be controlled for attraction and elution of DNA in porous silica. We report a novel extraction method of human genomic DNA from buccal swab and saliva samples. DNA is attracted onto a gold-coated microchip by an electric field and capillary action while the captured DNA is eluted by thermal heating at 70 °C. A prototype device was designed to handle four microchips, and a compatible protocol was developed. The extracted DNA using microchips was characterized by qPCR for different sample volumes, using different lengths of PCR amplicon, and nuclear and mitochondrial genes. In comparison with a commercial kit, an equivalent yield of DNA extraction was achieved with fewer steps. Room-temperature preservation for 1 month was demonstrated for captured DNA, facilitating straightforward collection, delivery, and handling of genomic DNA in an environment-friendly protocol.

  17. Dispersive Liquid-Liquid Microextraction in the Analysis of Milk and Dairy Products: A Review

    Directory of Open Access Journals (Sweden)

    Andrew Quigley

    2016-01-01

    Full Text Available Dispersive liquid-liquid microextraction (DLLME is an extraction technique developed within the last decade, which involves the dispersion of fine droplets of extraction solvent in an aqueous sample. Partitioning of analytes into the extraction phase is instantaneous due to the very high collective surface area of the droplets. This leads to very high enrichment factors and very low solvent consumption, relative to other liquid or solid phase extraction methods. A comprehensive review of the various modes of DLLME in the analysis of organic and inorganic analytes in dairy products (milk, cheese, infant formula, yogurt, and breast milk is presented here. Dairy products present a complex sample matrix and the removal of interfering matrix components can prove troublesome. This review focuses on sample pretreatment prior to the appropriate DLLME procedure, the extraction and dispersive solvents chosen, derivatisation methods, and analytical figures of merit. Where possible, a critical comparison of DLLME methods has been undertaken. The overall suitability, and limitations, of DLLME as a sample preparation technique for dairy products has been assessed.

  18. Liquid-liquid separation using steady-state bed coalescer

    Directory of Open Access Journals (Sweden)

    Šećerov-Sokolović Radmila M.

    2016-01-01

    Full Text Available This paper presents a literature review on the current understanding of liquid-liquid separation that is immensely widespread in practice, highlighting the steady-state bed coalescer being a good solution in various engineering application. Generally, the fibre bed coalescence has proven to be very effective separation method in the industry. Due to the complexity of bed coalescence phenomenon coalescer design and sizing procedure relies on experimental test. This review provides a research overview of the key phenomena essential for the efficient bed coalescence, such as mechanisms of droplet coalescence and emulsion flow through the fibre bed. In addition to this provides an overview of the current knowledge about coalescer´s design properties and variables such as: fluid velocity, fluid flow orientation/flow mode, fibre bed geometry, and bed length. [[Projekat Ministarstva nauke Republike Srbije, br. 172022

  19. Microrheology and Particle Dynamics at Liquid-Liquid Interfaces

    Science.gov (United States)

    Song, Yanmei

    The rheological properties at liquid-liquid interfaces are important in many industrial processes such as manufacturing foods, pharmaceuticals, cosmetics, and petroleum products. This dissertation focuses on the study of linear viscoelastic properties at liquid-liquid interfaces by tracking the thermal motion of particles confined at the interfaces. The technique of interfacial microrheology is first developed using one- and two-particle tracking, respectively. In one-particle interfacial microrheology, the rheological response at the interface is measured from the motion of individual particles. One-particle interfacial microrheology at polydimethylsiloxane (PDMS) oil-water interfaces depends strongly on the surface chemistry of different tracer particles. In contrast, by tracking the correlated motion of particle pairs, two-particle interfacial microrheology significantly minimizes the effects from tracer particle surface chemistry and particle size. Two-particle interfacial microrheology is further applied to study the linear viscoelastic properties of immiscible polymer-polymer interfaces. The interfacial loss and storage moduli at PDMS-polyethylene glycol (PEG) interfaces are measured over a wide frequency range. The zero-shear interfacial viscosity, estimated from the Cross model, falls between the bulk viscosities of two individual polymers. Surprisingly, the interfacial relaxation time is observed to be an order of magnitude larger than that of the PDMS bulk polymers. To explore the fundamental basis of interfacial nanorheology, molecular dynamics (MD) simulations are employed to investigate the nanoparticle dynamics. The diffusion of single nanoparticles in pure water and low-viscosity PDMS oils is reasonably consistent with the prediction by the Stokes-Einstein equation. To demonstrate the potential of nanorheology based on the motion of nanoparticles, the shear moduli and viscosities of the bulk phases and interfaces are calculated from single

  20. Study on liquid-liquid bimetal composite casting hammers

    Directory of Open Access Journals (Sweden)

    Rong Shoufan

    2014-09-01

    Full Text Available Crusher hammers for the mineral processing industry must meet the demands of both high wear resistance at the hammer head and high impact toughness at the hammer handle. The crusher hammers made of Hadfield steel have typically low service life of less than 40 hours. To solve the problem, a kind of bimetal crusher hammers made of high chromium cast iron (HCCI and low alloy steel (LAS has been successfully developed by using liquid-liquid composite casting. The microstructure and composite interface bonding was analyzed using optical microscope, SEM, EDX and XRD. Micrographs indicate that the composite interface is metallurgically bonded with a zigzag shape across the boundary and without unbound region or void. After heat treatment, the composite hammers have shown excellent properties. The hardness of HCCI is at least 63 HRC and its ak is greater than 3.5 J.cm-2/FONT>cm-2; the hardness of LAS is greater than 35 HRC and its ak is no less than 80 J.cm-2/FONT>cm-2. Diffusion of elements takes place at the interface and forms a transition region. The micro hardness increases from LAS to the interface and then to HCCI. Wear comparison was made separately between the bimetal composite hammer and a Hadfield steel hammer in two quarries of Jilin province and Liaoning province. The results showed that the liquid-liquid bimetal composite hammers did not have the falling off of hammer head or impact fracture phenomenon, and their service life was 3.75 times as long as that of the Hadfield steel hammers.

  1. Magnetic effervescent tablet-assisted ionic liquid dispersive liquid-liquid microextraction of selenium for speciation in foods and beverages.

    Science.gov (United States)

    Wang, Xiaojun; Wu, Long; Cao, Jiaqi; Hong, Xincheng; Ye, Rui; Chen, Weiji; Yuan, Ting

    2016-07-01

    A novel, simple and rapid method based on magnetic effervescent tablet-assisted ionic liquid dispersive liquid-liquid microextraction (MEA-IL-DLLME) followed by graphite furnace atomic absorption spectrometry (GFAAS) determination was established for the speciation of selenium in various food and beverage samples. In the procedure, a special magnetic effervescent tablet containing CO2 sources (sodium carbonate and sodium dihydrogenphosphate), ionic liquids and Fe3O4 magnetic nanoparticles (MNPs) was used to combine extractant dispersion and magnetic recovery procedures into a single step. The parameters influencing the microextraction efficiency, such as pH of the sample solution, volume of ionic liquid, amount of MNPs, concentration of the chelating agent, salt effect and matrix effect were investigated and optimised. Under the optimised conditions, the limits of detection (LODs) for Se(IV) were 0.021 μg l(-)(1) and the linear dynamic range was 0.05-5.0 μg l(-)(1). The relative standard deviation for seven replicate measurements of 1.0 μg l(-)(1) of Se(IV) was 2.9%. The accuracy of the developed method was evaluated by analysis of the standard reference materials (GBW10016 tea, GBW10017 milk powder, GBW10043 Liaoning rice, GBW10046 Henan wheat, GBW10048 celery). The proposed method was successfully applied to food and beverage samples including black tea, milk powder, mushroom, soybean, bamboo shoots, energy drink, bottled water, carbonated drink and mineral water for the speciation of Se(IV) and Se(VI) with satisfactory relative recoveries (92.0-108.1%).

  2. Determination of total iron in water and foods by dispersive liquid-liquid microextraction coupled with microvolume UV-vis spectrophotometry.

    Science.gov (United States)

    Peng, Bo; Shen, Yingping; Gao, Zhuantao; Zhou, Min; Ma, Yongjun; Zhao, Shengguo

    2015-06-01

    A novel microvolume UV-vis spectrophotometry method was proposed for the rapid determination of total iron coupling with an efficient pretreatment method known as dispersive liquid-liquid microextraction (DLLME). The basis of the method is a quantitative colorimetric reaction between ferrous iron and 2-(5-bromo-2-pyridylazo)-5-(diethyl amino) phenol (5-Br-PADAP) after the reduction of Fe(III) to Fe(II) by using ascorbic acid as reducing agent. Parameters related to the efficiency of microextraction, such as pH, complexant concentration, the volume ratio of disperser solvent and extraction solvent were discussed and optimized in detail. Under the optimized conditions, the absorbance was in proportion to iron concentration in the range of 5-400μgL(-1) with a correlation coefficient (R) of 0.9993. The limit of detection (LOD) and limit of quantitation (LOQ) were 1.5μgL(-1) and 5.2μgL(-1), respectively. The relative standard deviation (RSD) for samples were 1.37- 4.42% (n=3). Good recoveries of iron were obtained in the range of 95.4-103.2% in food samples, 96.9-103.6% in water samples and 98.8-102.3% in Certified Reference Material. The proposed method was rapid, reliable and high-selective for the determination of total iron in food and water samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Determination of benzophenone-3 and its main metabolites in human serum by dispersive liquid-liquid microextraction followed by liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Tarazona, Isuha; Chisvert, Alberto; Salvador, Amparo

    2013-11-15

    A new analytical method for the determination of benzophenone-3 (2-hydroxy-4-methoxybenzophenone), and its main metabolites (2,4-dihydroxybenzophenone and 2,2'-dihydroxy-4-methoxybenzophenone) in human serum is presented. The method is based on dispersive liquid-liquid microextraction (DLLME) as preconcentration and clean-up technique, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS). Acidic hydrolysis and protein precipitation with HCl 6 M (1:1) (100 °C, 1 h) were carried out before extraction. The variables involved in the DLLME process were studied. Under the optimized conditions, 70 µL of acetone (disperser solvent) and 30 µL of chloroform (extraction solvent) were mixed and rapidly injected into 800 µL of hydrolyzed serum sample. Sample pH or ionic strength adjustment were not necessary. The method was validated by analyzing spiked human serum samples. No satisfactory recoveries were obtained when aqueous standards or standards prepared in synthetic serum were used, but excellent recoveries were achieved by using matrix-matched calibration standards. Moreover, limits of detection in the low µg L(-1) level and good repeatability were obtained. In order to show the applicability of the proposed method in the study of percutaneous absorption processes, it was applied to the analysis of serum samples from two volunteers after topical application of a sunscreen cosmetic product containing 2-hydroxy-4-methoxybenzophenone. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Determination of immunosuppressive drugs in human urine and serum by surface-assisted laser desorption/ionization mass spectrometry with dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Chen, Pin-Shiuan; Cheng, Yu-Han; Lin, Sheng-Yu; Chang, Sarah Y

    2016-01-01

    A rapid and sensitive method for the determination of immunosuppressive drugs through surface-assisted laser desorption/ionization mass spectrometric detection (SALDI/MS) was developed. Colloidal Pd and α-cyano-4-hydroxycinnamic acid (CHCA) were used as the SALDI co-matrix. To eliminate interference and enhance the sensitivity, dispersive liquid-liquid microextraction (DLLME) was employed to extract the immunosuppressive drugs from the aqueous solutions. Under optimal extraction and detection conditions, calibration curves for cyclosporine and everolimus in aqueous solutions were linear over a concentration range from 0.01 to 1.20 μM. For sirolimus, the linear concentration range of the calibration curve was from 0.05 to 2.00 μM. The limits of detection (LODs) were calculated to be 3, 3, and 14 nM for cyclosporine, everolimus, and sirolimus, respectively. The enrichment factors of DLLME were calculated to be 108, 122, and 101 for cyclosporine, everolimus, and sirolimus, respectively. This novel method was successfully applied for the determination of immunosuppressive drugs in human urine and serum samples.

  5. Determination of estrogenic mycotoxins in environmental water samples by low-toxicity dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Emídio, Elissandro Soares; da Silva, Claudia Pereira; de Marchi, Mary Rosa Rodrigues

    2015-04-24

    A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 μL bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L(-1), respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of β-zearalanol and zearalanone in the river water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Comparison of two novel in-syringe dispersive liquid-liquid microextraction techniques for the determination of iodide in water samples using spectrophotometry.

    Science.gov (United States)

    Kaykhaii, Massoud; Sargazi, Mona

    2014-01-01

    Two new, rapid methodologies have been developed and applied successfully for the determination of trace levels of iodide in real water samples. Both techniques are based on a combination of in-syringe dispersive liquid-liquid microextraction (IS-DLLME) and micro-volume UV-Vis spectrophotometry. In the first technique, iodide is oxidized with nitrous acid to the colorless anion of ICl2(-) at high concentration of hydrochloric acid. Rhodamine B is added and by means of one step IS-DLLME, the ion-pair formed was extracted into toluene and measured spectrophotometrically. Acetone is used as dispersive solvent. The second method is based on the IS-DLLME microextraction of iodide as iodide/1, 10-phenanthroline-iron((II)) chelate cation ion-pair (colored) into nitrobenzene. Methanol was selected as dispersive solvent. Optimal conditions for iodide extraction were determined for both approaches. Methods are compared in terms of analytical parameters such as precision, accuracy, speed and limit of detection. Both methods were successfully applied to determining iodide in tap and river water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Nonchromatographic speciation of selenium in edible oils using dispersive liquid-liquid microextraction and electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    López-García, Ignacio; Vicente-Martínez, Yesica; Hernández-Córdoba, Manuel

    2013-10-02

    A methodology for the nonchromatographic separation of the main selenium species present in edible oils is presented. Dispersive liquid-liquid microextraction is used to extract inorganic selenium (iSe), seleno-L-cystine (SeCys₂), seleno-L-methionine (SeMet), and selenocystamine (SeCM) into a slightly acidic aqueous medium. The selenium total (tSe) content is measured in the extracts by electrothermal atomic absorption spectrometry. By repeating the microextraction stage using an ionic liquid instead of water, the sum of SeCys₂, SeMet, and SeCM is obtained and iSe is calculated by difference. The detection limit is 0.03 ng of Se per gram of oil. The fractionation of the edible oils by solid phase extraction followed by dispersive liquid-liquid extraction and atomic absorption measurement also permits speciation of iSe to be carried out. Data for tSe and iSe levels of 15 samples of different origin are given.

  8. Dispersive liquid-liquid microextraction combined with gas chromatography-electron capture detection for the determination of polychlorinated biphenyls in soils

    Energy Technology Data Exchange (ETDEWEB)

    Hu Jia [Department of Chemical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027 (China); Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, Central China Normal University, Wuhan 430079 (China); Fu Lingyan; Zhao Xinna; Liu Xiujuan [Key Laboratory of Pesticide and Chemical Biology of Ministry of Education, Central China Normal University, Wuhan 430079 (China); Wang Huili; Wang Xuedong [School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou 325035 (China); Dai Liyan, E-mail: dailiyan@zju.edu.cn [Department of Chemical Engineering, Zhejiang University, Hangzhou, Zhejiang 310027 (China)

    2009-04-27

    In this article, dispersive liquid-liquid microextraction (DLLME) and gas chromatography-electron capture detection (GC-ECD) were presented for the extraction and determination of five polychlorinated biphenyls (PCBs) in soil samples. Acetone was used as extraction solvent for the extraction of PCBs from soil samples. In DLLME, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to chlorobenzene when the extraction process began. The main advantages of this method are quick speed, high enrichment factor, high recovery and good repeatability. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 2 to 2000 {mu}g kg{sup -1}for PCB 52, and 0.4 to 400 {mu}g kg{sup -1} for other target analytes. Coefficients of correlation (r{sup 2}) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking soil samples at a concentration level of 10 {mu}g kg{sup -1} for PCBs. The relative standard deviations (RSDs, n = 11) varied between 2.2% and 6.4%. The limits of detection (LODs), based on signal-to-noise (S/N) of 3, were between 0.20 and 0.50 {mu}g kg{sup -1}. The relative recoveries of the five PCBs from soil S1, S2 and S3 at spiking levels of 10, 20 and 50 {mu}g kg{sup -1} were in the range of 88.70-103.8%, 82.50-106.3% and 82.30-113.6%, respectively. Therefore, DLLME combined with GC-ECD can be successfully applied for the determination of trace PCB residues in real soil samples.

  9. Relation between the Widom Line and the Dynamic Crossover in Systems with a Liquid-Liquid Phase Transition

    National Research Council Canada - National Science Library

    Limei Xu; Pradeep Kumar; S. V. Buldyrev; S. -H. Chen; P. H. Poole; F. Sciortino; H. E. Stanley

    2005-01-01

    We investigate, for two water models displaying a liquid-liquid critical point, the relation between changes in dynamic and ther-modynamic anomalies arising from the presence of the liquid-liquid critical point...

  10. Toward mechanistic understanding of nuclear reprocessing chemistries by quantifying lanthanide solvent extraction kinetics via microfluidics with constant interfacial area and rapid mixing.

    Science.gov (United States)

    Nichols, Kevin P; Pompano, Rebecca R; Li, Liang; Gelis, Artem V; Ismagilov, Rustem F

    2011-10-05

    The closing of the nuclear fuel cycle is an unsolved problem of great importance. Separating radionuclides produced in a nuclear reactor is useful both for the storage of nuclear waste and for recycling of nuclear fuel. These separations can be performed by designing appropriate chelation chemistries and liquid-liquid extraction schemes, such as in the TALSPEAK process (Trivalent Actinide-Lanthanide Separation by Phosphorus reagent Extraction from Aqueous Komplexes). However, there are no approved methods for the industrial scale reprocessing of civilian nuclear fuel in the United States. One bottleneck in the design of next-generation solvent extraction-based nuclear fuel reprocessing schemes is a lack of interfacial mass transfer rate constants obtained under well-controlled conditions for lanthanide and actinide ligand complexes; such rate constants are a prerequisite for mechanistic understanding of the extraction chemistries involved and are of great assistance in the design of new chemistries. In addition, rate constants obtained under conditions of known interfacial area have immediate, practical utility in models required for the scaling-up of laboratory-scale demonstrations to industrial-scale solutions. Existing experimental techniques for determining these rate constants suffer from two key drawbacks: either slow mixing or unknown interfacial area. The volume of waste produced by traditional methods is an additional, practical concern in experiments involving radioactive elements, both from disposal cost and experimenter safety standpoints. In this paper, we test a plug-based microfluidic system that uses flowing plugs (droplets) in microfluidic channels to determine absolute interfacial mass transfer rate constants under conditions of both rapid mixing and controlled interfacial area. We utilize this system to determine, for the first time, the rate constants for interfacial transfer of all lanthanides, minus promethium, plus yttrium, under TALSPEAK

  11. Investigation of liquid-liquid drop coalescence using tomographic PIV

    Science.gov (United States)

    Ortiz-Dueñas, Cecilia; Kim, Jungyong; Longmire, Ellen K.

    2010-07-01

    High-speed tomographic PIV was used to investigate the coalescence of drops placed on a liquid/liquid interface; the coalescence of a single drop and of a drop in the presence of an adjacent drop (side-by-side drops) was investigated. The viscosity ratio between the drop and surrounding fluids was 0.14, the Ohnesorge number (Oh = μd/(ρdσD)1/2) was 0.011, and Bond numbers (Bo = ( ρ d - ρ s ) gD 2/ σ) were 3.1-7.5. Evolving volumetric velocity fields of the full coalescence process allowed for quantification of the velocity scales occurring over different time scales. For both single and side-by-side drops, the coalescence initiates with an off-axis film rupture and film retraction speeds an order of magnitude larger than the collapse speed of the drop fluid. This is followed by the formation and propagation of an outward surface wave along the coalescing interface with wavelength of approximately 2D. For side-by-side drops, the collapse of the first drop is asymmetric due to the presence of the second drop and associated interface deformation. Overall, tomographic PIV provides insight into the flow physics and inherent three-dimensionalities in the coalescence process that would not be achievable with flow visualization or planar PIV only.

  12. Drop impact on a liquid-liquid interface

    Science.gov (United States)

    Mohamed-Kassim, Zulfaa; Longmire, Ellen K.

    2003-11-01

    The effects of Reynolds number (Re) on the gravity-driven impact of a single drop onto a liquid-liquid interface were studied experimentally using the particle image velocimetry method. The liquid beneath the interface was identical to the drop liquid. Two liquids with different viscosities were used as the ambient above the interface resulting in viscosity ratios (drop to ambient) of 0.14 and 0.33. Index matching and a slight camera inclination were employed to eliminate optical distortion. Image planes were captured at a rate of 500 Hz, and velocity fields were determined from consecutive images. The flow Reynolds numbers based on drop impact velocity and ambient viscosity were 20 and 68 for the lower and higher viscosity ratios, respectively. During the approach toward the interface, the drop shape was more oblate for the higher Re case. At the same time, viscous stresses generated a vortex ring inside each drop and a wake behind it. Each wake contained a detached ring of similar sign to the ring inside the drop. The subsequent deformation of the drop and the interface due to impact was observed to be more radical in the higher Re case. The impingement and shearing of the trailing wake on the upper surface of each drop played a significant role in dissipating the vorticity inside both drops, and the vorticity dissipated faster for lower Re.

  13. Liquid-liquid equilibria for ternary polymer mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Suk Yung [Division of Chemical Engineering and Molecular Thermodynamics Laboratory, Hanyang University, Seoul 133-791 (Korea, Republic of); Bae, Young Chan, E-mail: ycbae@hanyang.ac.kr [Division of Chemical Engineering and Molecular Thermodynamics Laboratory, Hanyang University, Seoul 133-791 (Korea, Republic of)

    2011-01-24

    Graphical abstract: We developed a molecular thermodynamic model for multicomponent systems and discribed the phase equilibrium for ternary polymer mixtures by using the model parameters obtained from the binary systems. Research highlights: {yields} Model parameters were obtained from the binary systems. {yields} The obtained parameters were directly used to predict the ternary data. {yields} The undetermined parameters were used to correlate the ternary data. {yields} The proposed model agreed well with the experimental data. - Abstract: A molecular thermodynamic model for multicomponent systems based on a closed-packed lattice model is presented based on two contributions; entropy and energy contribution. The calculated liquid-liquid equilibria of ternary chainlike mixtures agreed with Monte Carlo simulation results. The proposed model can satisfactorily predict Types 0, 1, 2 and 3 phase separations of the Treybal classification. The model parameters obtained from the binary systems were used to directly predict real ternary systems and the calculated results correlated well with experimental data using few adjustable parameters. Specific interactions in associated binary systems were considered using a secondary lattice.

  14. Intra-molecular coupling as a mechanism for a liquid-liquid phase transition

    OpenAIRE

    Franzese, Giancarlo; Marques, Manuel I.; Stanley, H. Eugene

    2001-01-01

    We study a model for water with a tunable intra-molecular interaction $J_\\sigma$, using mean field theory and off-lattice Monte Carlo simulations. For all $J_\\sigma\\geq 0$, the model displays a temperature of maximum density.For a finite intra-molecular interaction $J_\\sigma > 0$,our calculations support the presence of a liquid-liquid phase transition with a possible liquid-liquid critical point for water, likely pre-empted by inevitable freezing. For J=0 the liquid-liquid critical point dis...

  15. An automatic, vigorous-injection assisted dispersive liquid-liquid microextraction technique for stopped-flow spectrophotometric detection of boron.

    Science.gov (United States)

    Alexovič, Michal; Wieczorek, Marcin; Kozak, Joanna; Kościelniak, Paweł; Balogh, Ioseph S; Andruch, Vasil

    2015-02-01

    A novel automatic vigorous-injection assisted dispersive liquid-liquid microextraction procedure based on the use of a modified single-valve sequential injection manifold (SV-SIA) was developed and applied for determination of boron in water samples. The major novelties in the procedure are the achieving of efficient dispersive liquid-liquid microextraction by means of single vigorous-injection (250 µL, 900 µL s(-1)) of the extraction solvent (n-amylacetate) into aqueous phase resulting in the effective dispersive mixing without using dispersive solvent and after self-separation of the phases, as well as forwarding of the extraction phase directly to a Z-flow cell (10 mm) without the use of a holding coil for stopped-flow spectrophotometric detection. The calibration working range was linear up to 2.43 mg L(-1) of boron at 426nm wavelength. The limit of detection, calculated as 3s of a blank test (n=10), was found to be 0.003 mg L(-1), and the relative standard deviation, measured as ten replicable concentrations at 0.41 mg L(-1) of boron was determined to be 5.6%. The validation of the method was tested using certified reference material. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Low-temperature derivatization followed by vortex-assisted liquid-liquid microextraction for the analysis of polyamines in Nicotiana Tabacum.

    Science.gov (United States)

    Cai, Kai; Cai, Bin; Xiang, Zhangmin; Zhao, Huina; Rao, Xingyi; Pan, Wenjie; Lei, Bo

    2016-07-01

    Polyamines are ubiquitous polycationic molecules that play a key role in many biological processes such as nucleic acid metabolism, protein synthesis, cell growth, and nicotine synthesis precursors. This work describes a rapid, sensitive, convenient, green, and cost-effective method for the determination of polyamines in Nicotiana tabacum by ultra high performance liquid chromatography with photodiode array detection. The analytes were derivatized with 3,5-dinitrobenzoyl chloride at low temperature (about 4°C) and then extracted with vortex-assisted liquid-liquid microextraction. The experimental designs based on quarter-fractional factorial design and Doehlert design were used to screen and optimize the important factors in microextraction process. Under the optimal conditions, the method was linear over 0.05-8.00 μg/mL with an r(2) ≥ 0.992 and exhibited good repeatability and reproducibility less than 6.0 and 6.9%, respectively. The limit of detection ranged between 0.013 and 0.029 μg/g. The newly developed method was successfully employed to analyze different leaf samples of Nicotiana tabacum, among which the polyamines contents were found to be very different. Moreover, tyramine, 1,3-diaminopropane, homospermidine, and canavalmine were tentatively identified with the electrospray ionization quadrupole time-of-flight mass spectrometry. To our knowledge, this is the first report of identification of canavalmine in Nicotiana Tabacum. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Ultrasound-assisted ionic liquid dispersive liquid-liquid microextraction combined with graphite furnace atomic absorption spectrometric for selenium speciation in foods and beverages.

    Science.gov (United States)

    Tuzen, Mustafa; Pekiner, Ozlem Zeynep

    2015-12-01

    A rapid and environmentally friendly ultrasound assisted ionic liquid dispersive liquid liquid microextraction (USA-IL-DLLME) was developed for the speciation of inorganic selenium in beverages and total selenium in food samples by using graphite furnace atomic absorption spectrometry. Some analytical parameters including pH, amount of complexing agent, extraction time, volume of ionic liquid, sample volume, etc. were optimized. Matrix effects were also investigated. Enhancement factor (EF) and limit of detection (LOD) for Se(IV) were found to be 150 and 12 ng L(-1), respectively. The relative standard deviation (RSD) was found 4.2%. The accuracy of the method was confirmed with analysis of LGC 6010 Hard drinking water and NIST SRM 1573a Tomato leaves standard reference materials. Optimized method was applied to ice tea, soda and mineral water for the speciation of Se(IV) and Se(VI) and some food samples including beer, cow's milk, red wine, mixed fruit juice, date, apple, orange, grapefruit, egg and honey for the determination of total selenium. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. An evaporation-assisted dispersive liquid-liquid microextraction technique as a simple tool for high performance liquid chromatography tandem-mass spectrometry determination of insecticides in wine.

    Science.gov (United States)

    Timofeeva, Irina; Kanashina, Daria; Moskvin, Leonid; Bulatov, Andrey

    2017-08-25

    A sample pre-treatment technique based on evaporation-assisted dispersive liquid-liquid microextraction (EVA-DLLME), followed by HPLC-MS/MS has been developed for the determination of organophosphate insecticides (malathion, diazinon, phosalone) in wine samples. The procedure includes the addition of mixture of organic solvents (with density higher than water), consisting of the extraction (low density) and volatile (high density) solvents, to aqueous sample followed by heating of the mixture obtained, what promotes the volatile solvent evaporation and moving extraction solvent droplets from down to top of the aqueous sample and, as a consequence, microextraction of target analytes. To initiate the evaporation process an initiator is required. It was established that hexanol (extraction solvent) and dichloromethane (volatile solvent) mixture (1:1, v/v) provides effective microextraction of the insecticides from wine samples with recovery from 92 to 103%. The conditions of insecticides' microextraction such as selection of extraction solvent, ratio of hexanol/dichloromethane and hexanol/sample, type and concentration of initiator, and effect of ethanol as one of the main components of wine have been studied. Under optimal experimental conditions the linear detection ranges were found to be 10(-7)-10(-3)gL(-1) for malathion, 10(-9)-10(-4)gL(-1) for diazinon, and 10(-6)-10(-2)gL(-1) for phosalone. The LODs, calculated from a blank test, based on 3σ, found to be 3×10(-8)gL(-1) for malathion, 3×10(-10)gL(-1) for diazinon and 3×10(-7)gL(-1) for phosalone. The advantages of EVA-DLLME are the rapidity, simplicity, high sample throughput and low cost. As an outcome, the analytical results agreed fairly well with the results obtained by a reference GC-MS method. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Towards an interpretation of the mechanism of the actinides(III)/lanthanides(III) separation by synergistic solvent extraction with nitrogen-containing polydendate ligands; Vers une interpretation des mecanismes de la separation actinides(III)/lanthanides(III) par extraction liquide-liquide synergique impliquant des ligands polyazotes

    Energy Technology Data Exchange (ETDEWEB)

    Francois, N. [CEA/VALRHO - site de Marcoule, Dept. de Recherche en Retraitement et en Vitrification, (DRRV), 30 - Marcoule (France); Universite Henri Poincare, 54 - Vandoeuvre-les-Nancy (France)

    2000-07-01

    In the field of the separation of long-lived radionuclides from the wastes produced by nuclear fuel reprocessing, aromatic nitrogen-containing polydendate ligands are potential candidates for the selective extraction, alone or in synergistic mixture with acidic extractants, of trivalent actinides from trivalent lanthanides. The first part of this work deals with the complexation of trivalent f cations with various nitrogen-containing ligands (poly-pyridine analogues). Time-resolved laser-induced fluorimetry (TRLIF) and UV-visible spectrophotometry were used to determine the nature and evaluate the stability of each complex. Among the ligands studied, the least basic Me-Btp proved to be highly selective towards americium(III) in acidic solution. In the second part, two synergistic systems (nitrogen-containing polydendate ligand and lipophilic carboxylic acid) are studied and compared in regard to the extraction and separation of lanthanides(III) and actinides(III). TRLIF and gamma spectrometry allowed the nature of the extracted complexes and the optimal conditions of efficiency of both systems to be determined. Comparison between these different studies showed that the selectivity of complexation of trivalent f cations by a given nitrogen-containing polydendate ligand could not always be linked to the Am(III)Eu(III) selectivity reached in synergistic extraction. The latter depends on the 'balance' between the acid-basic properties on the one hand, and on the hard-soft characteristics on the other hand, of both components of synergistic system. (author)

  20. Liquid-liquid equilibria of the ternary system thiophene + octane + dimethyl sulfoxide at several temperatures.

    Science.gov (United States)

    Zhang, Wenlin; Hou, Kaihu; Mi, Guanjie; Chen, Na

    2010-01-01

    Liquid-liquid equilibria (LLE) data of the ternary system thiophene + octane + dimethyl sulfoxide at 40 degrees C, 50 degrees C, and 60 degrees C under atmospheric pressure were determined using an equilibrium cell with the standard curve method. The distribution of thiophene between extract and raffinate was measured and a practical formula of equilibria data for industrial extraction was proposed. NRTL model and UNIQUAC model were used to correlate and calculate LLE data of the system, and model parameters were determined using the simplex optimization method and imitative Newton method with a minimized objective function of mole fraction deviation. The rule of thermodynamic equilibria was used to deal with multi-roots problem in correlating process. Agreement between predicted and experimental data was satisfactory. The average absolute deviations of the NRTL and UNIQUAC models of thiophene mass fraction were 0.0040 and 0.0078, respectively. Both NRTL and UNIQUAC models were suitable for the calculation of LLE data of the ternary system thiophene + octane + dimethyl sulfoxide. The correlation accuracy of NRTL model is inferior to that of UNIQUAC model.

  1. Mass transfer and chemical reaction in gas-liquid-liquid systems.

    NARCIS (Netherlands)

    Brilman, Derk Willem Frederik

    1998-01-01

    Gas-liquid-liquid reaction systems may be encountered in several important fields of application as e.g. hydroformylation, alkylation, carboxylation, polymerisation, hydrometallurgy, biochemical processes and fine chemicals manufacturing. However, the reaction engineering aspects of these systems

  2. Continuous gas/liquid–liquid/liquid flow synthesis of 4-fluoropyrazole derivatives by selective direct fluorination

    Directory of Open Access Journals (Sweden)

    Jessica R. Breen

    2011-08-01

    Full Text Available 4-Fluoropyrazole systems may be prepared by a single, sequential telescoped two-step continuous gas/liquid–liquid/liquid flow process from diketone, fluorine gas and hydrazine starting materials.

  3. Multiple liquid-liquid critical points and density anomaly in core-softened potentials

    OpenAIRE

    Barbosa, Marco Aurélio Alves; Torres, Evy Augusto Salcedo; Barbosa, Marcia Cristina Bernardes

    2013-01-01

    The relation between liquid-liquid phase transitions andwaterlike density anomalies in core-softened potentials of fluids was investigated in an exactly solvable one-dimensional lattice model and in a three-dimensional fluid with a Fermi-like potential, the latter by molecular dynamics. Both systems were shown to present three liquid phases, two liquid-liquid phase transitions closely connected to two distinct regions of anomalous density increase. We propose that an oscillatory behavior obse...

  4. Multiple liquid-liquid critical points and anomalies in core-softened potentials

    OpenAIRE

    Barbosa, Marco Aurélio A.; Salcedo, Evy; Barbosa, Marcia

    2012-01-01

    The relation between liquid-liquid phase transitions and waterlike density anomalies in core-softened potentials of fluids was investigated in an exactly solvable one dimensional lattice model and a in a three dimensional fluid with fermi-like potential, the latter by molecular dynamics. Both systems were shown to present three liquid phases, two liquid-liquid phase transitions closely connected to two distinct regions of anomalous density increase. We propose that an oscillatory behavior obs...

  5. Low-density-solvent-based air-assisted liquid-liquid microextraction followed by gas chromatography with flame ionization detection for the determination of synthetic phenolic antioxidants in milk samples.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Afshar Mogaddam, Mohammad Reza

    2016-03-01

    A simple and rapid sample pretreatment technique termed low-density-solvent-based air-assisted liquid-liquid microextraction has been developed for the extraction and preconcentration of three synthetic phenolic antioxidants including butylated hydroxyanisole, butylated hydroxytoluene, and tert-butyl hydroquinone from milk samples prior to their analysis by gas chromatography with flame ionization detection. In this method, initially trichloroacetic acid as a proteins precipitation agent is added to the sample, and then it is sonicated and centrifuged. The obtained aqueous phase is removed and the analytes extracted by the proposed method using a low-density organic solvent. Some important parameters such as type and volume of extraction solvent, ionic strength, pH, and centrifugation rate and time were studied. Under the optimum conditions, enrichment factors were obtained in the range of 501-614. LODs and quantification were between 0.76-1.16 and 2.66-3.96 ng mL(-1) , respectively. This method is rapid and requires less than 15 min for sample preparation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Trace determination of lead in lipsticks and hair dyes using microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Sharafi, K; Fattahi, N; Pirsaheb, M; Yarmohamadi, H; Fazlzadeh Davil, M

    2015-10-01

    A novel microwave-assisted dispersive liquid-liquid microextraction (MADLLME) technique according to the solidification of a floating organic droplet (SFO) and graphite furnace atomic absorption spectrometry (GFAAS) used for the extraction and determination of lead ions in lipsticks and hair dyes made in different countries. Lipstick and hair dye samples of different brands and colours were collected from local market in Kermanshah, Iran. After sample treatment with microwave-assisted acid digestion, an appropriate mixture of acetone, 1-undecanol and diethyl dithiophosphoric acid was injected rapidly into the aqueous sample containing lead ions, and as a result, cloudy mixture was formed. After centrifugation, the test tube was cooled for few minutes. The solidified 1-undecanol on top of the solution was transferred into a suitable vial and injected into the analytical instrument. Under the optimum experimental conditions (extraction solvent: 30 μL of 1-undecanol; disperser solvent: 500 μL of acetone; ligand concentration: 0.15% (v/v); pH: ~1.5 and without salt added), the enhancement factor of 96 was obtained. The calibration graphs were linear in the range of 0.3-50 μg kg(-1) with a correlation coefficient (r(2) ) more than 0.995. The detection limit was 0.1 μg kg(-1) . Consequently, the developed method was successfully applied to extract and determine lead ions in the lipsticks and hair dyes, and favourable results were obtained. The proposed method which applied in cosmetics showed excellent relative recoveries (90-109.7%) with relative standard deviations market is far below the recommended limits as applied in Germany (20 mg kg(-1) ) and Canada (10 mg kg(-1) ) and confirmed that very low levels of lead are technically available in the final cosmetic products. © 2015 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  7. Hollow fiber liquid-liquid-liquid microextraction followed by solid-phase microextraction and in situ derivatization for the determination of chlorophenols by gas chromatography-electron capture detection.

    Science.gov (United States)

    Saraji, Mohammad; Ghani, Milad

    2015-10-30

    A method based on the combination of hollow fiber liquid-liquid-liquid microextraction and solid-phase microextraction (SPME) followed by gas chromatography-electron capture detection was developed for the determination of chlorophenols in water and wastewater samples. Silica microstructures fabricated on the surface of a stainless steel wire were coated by an organic solvent and used as a SPME fiber. The analytes were extracted through a hollow fiber membrane containing n-decane from sample solution to an alkaline aqueous acceptor phase. They were then extracted and in situ derivatized on the SPME fiber using acetic anhydride. Experimental parameters such as the type of extraction solvent, acceptor phase NaOH concentration, donor phase HCl concentration, the amount of derivatizing reagent, salt concentration, stirring rate and extraction time were investigated and optimized. The precision of the method for the analytes at 0.02-30μgL(-1) concentration level ranged from 7.1 to 10.2% (as intra-day relative standard deviation) and 6.4 to 9.8% (as inter-day relative standard deviation). The linear dynamic ranges were in the interval of 5-500μgL(-1), 0.05-5μgL(-1), 0.02-1μgL(-1) and 0.001-0.5μgL(-1) for 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol, respectively. The enrichment factors were between 432 and 785. The limits of detection were in the range of 0.0004-1.2μgL(-1). Tap water, well water and wastewater samples were also analyzed to evaluate the method capability for real sample analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Liquid-liquid equilibrium of water + PEG 8000 + magnesium sulfate or sodium sulfate aqueous two-phase systems at 35°C: experimental determination and thermodynamic modeling

    Directory of Open Access Journals (Sweden)

    B. D. Castro

    2005-09-01

    Full Text Available Liquid-liquid extraction using aqueous two-phase systems is a highly efficient technique for separation and purification of biomolecules due to the mild properties of both liquid phases. Reliable data on the phase behavior of these systems are essential for the design and operation of new separation processes; several authors reported phase diagrams for polymer-polymer systems, but data on polymer-salt systems are still relatively scarce. In this work, experimental liquid-liquid equilibrium data on water + polyethylene glycol 8000 + magnesium sulfate and water + polyethylene glycol 8000 + sodium sulfate aqueous two-phase systems were obtained at 35°C. Both equilibrium phases were analyzed by lyophilization and ashing. Experimental results were correlated with a mass-fraction-based NRTL activity coefficient model. New interaction parameters were estimated with the Simplex method. The mean deviations between the experimental and calculated compositions in both equilibrium phases is about 2%.

  9. (Liquid + liquid) equilibrium data for the ternary systems (cycloalkane + ethylbenzene + 1-ethyl-3-methylimidazolim ethylsulfate) at T = 298.15 K and atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Emilio J. [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain); Laboratory of Separation and Reaction Engineering, LSRE, Departamento de Engenharia Quimica, Facultade de Engenharia, Universidade de Porto, Rua Dr. Roberto Frias, 4200-465 Porto (Portugal); Calvar, Noelia, E-mail: noecs@uvigo.e [Laboratory of Separation and Reaction Engineering, LSRE, Departamento de Engenharia Quimica, Facultade de Engenharia, Universidade de Porto, Rua Dr. Roberto Frias, 4200-465 Porto (Portugal); Dominguez, Irene; Dominguez, Angeles [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain)

    2011-05-15

    Research highlights: [EMim][ESO{sub 4}] was studied as solvent to extract ethylbenzene from cycloalkanes. (Liquid + liquid) equilibrium data were measured at 298.15K and atmospheric pressure. Selectivity and solute distribution ratio were obtained and compared with literature. Experimental data were satisfactorily correlated using NRTL and UNIQUAC models. [EMim][ESO{sub 4}] can be used as solvent for the studied (liquid + liquid) extraction. - Abstract: In this paper, (liquid + liquid) equilibrium (LLE) data for the ternary systems (cyclohexane, or cyclooctane, or methylcyclohexane + ethylbenzene + 1-ethyl-3-methylimidazolium ethylsulfate) have been determined experimentally at T = 298.15 K and atmospheric pressure. The solubility curves and the tie-line compositions of the conjugate phases were obtained by means of density. The degree of consistency of the tie-lines was tested using the Othmer-Tobias equation, and the Non-Random Two-Liquid (NRTL) and the Universal Quasi-Chemical (UNIQUAC) models were used to correlate the phase equilibrium in the systems. Selectivity and solute distribution ratio were evaluated for the immiscible region.

  10. Liquid-liquid phase separation of freely falling undercooled ternary Fe-Cu-Sn alloy

    Science.gov (United States)

    Wang, W. L.; Wu, Y. H.; Li, L. H.; Zhai, W.; Zhang, X. M.; Wei, B.

    2015-11-01

    The active modulation and control of the liquid phase separation for high-temperature metallic systems are still challenging the development of advanced immiscible alloys. Here we present an attempt to manipulate the dynamic process of liquid-liquid phase separation for ternary Fe47.5Cu47.5Sn5 alloy. It was firstly dispersed into numerous droplets with 66 ~ 810 μm diameters and then highly undercooled and rapidly solidified under the containerless microgravity condition inside drop tube. 3-D phase field simulation was performed to explore the kinetic evolution of liquid phase separation. Through regulating the combined effects of undercooling level, phase separation time and Marangoni migration, three types of separation patterns were yielded: monotectic cell, core shell and dispersive structures. The two-layer core-shell morphology proved to be the most stable separation configuration owing to its lowest chemical potential. Whereas the monotectic cell and dispersive microstructures were both thermodynamically metastable transition states because of their highly active energy. The Sn solute partition profiles of Fe-rich core and Cu-rich shell in core-shell structures varied only slightly with cooling rate.

  11. Liquid-liquid phase separation of freely falling undercooled ternary Fe-Cu-Sn alloy

    Science.gov (United States)

    Wang, W .L.; Wu, Y. H.; Li, L. H.; Zhai, W.; Zhang, X. M.; Wei, B.

    2015-01-01

    The active modulation and control of the liquid phase separation for high-temperature metallic systems are still challenging the development of advanced immiscible alloys. Here we present an attempt to manipulate the dynamic process of liquid-liquid phase separation for ternary Fe47.5Cu47.5Sn5 alloy. It was firstly dispersed into numerous droplets with 66 ~ 810 μm diameters and then highly undercooled and rapidly solidified under the containerless microgravity condition inside drop tube. 3-D phase field simulation was performed to explore the kinetic evolution of liquid phase separation. Through regulating the combined effects of undercooling level, phase separation time and Marangoni migration, three types of separation patterns were yielded: monotectic cell, core shell and dispersive structures. The two-layer core-shell morphology proved to be the most stable separation configuration owing to its lowest chemical potential. Whereas the monotectic cell and dispersive microstructures were both thermodynamically metastable transition states because of their highly active energy. The Sn solute partition profiles of Fe-rich core and Cu-rich shell in core-shell structures varied only slightly with cooling rate. PMID:26552711

  12. Simultaneous quantification of lycopene, β-carotene, retinol and α -tocopherol in plasma after a simple extraction procedure: stability study and application to human volunteers

    OpenAIRE

    Charão, Mariele F.; Moro, Angela M.; Brucker, Natália; Bulcão, Rachel P.; Baierle, Marília; Freitas, Fernando; Durgante, Juliano; Nascimento, Sabrina; Bubols, Guilherme B.; Saldiva, Paulo H.; Bohrer, Denise; Garcia, Solange C.

    2012-01-01

    A method for the simultaneous quantification of lycopene, β-carotene, retinol and α-tocopherol by high-performance liquid chromatography (HPLC) with Vis/fluorescence detection with isocratic elution was optimized and validated. The method consists of a rapid and simple liquid-liquid extraction procedure and a posterior quantification of extracted supernatants by HPLC. Aliquots of plasma were stored at -20°C for three months for stability study. The methodology was applied to samples from pain...

  13. Liquid-liquid equilibria for the ternary systems sulfolane + octane + benzene, sulfolane + octane + toluene and sulfolane + octane + p-xylene

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Kim, H. [Seoul National Univ. (Korea, Republic of). Dept. of Chemical Engineering

    1995-03-01

    Sulfolane is widely used as a solvent for the extraction of aromatic hydrocarbons. Ternary phase equilibrium data are essential for the proper understanding of the solvent extraction process. Liquid-liquid equilibrium data for the systems sulfolane + octane + benzene, sulfolane + octane + toluene and sulfolane + octane + p-xylene were determined at 298.15, 308.15, and 318.15 K. Tie line data were satisfactorily correlated by the Othmer and Tobias method. The experimental data were compared with the values calculated by the UNIQUAC and NRTL models. Good quantitative agreement was obtained with these models. However, the calculated values based on the NRTL model were found to be better than those based on the UNIQUAC model.

  14. (Liquid + liquid) equilibria in ternary aqueous mixtures of phosphoric acid with organic solvents at T = 298.2 K

    Energy Technology Data Exchange (ETDEWEB)

    Ghanadzadeh, H., E-mail: hggilani@guilan.ac.i [Department of Chemistry, Faculty of Science, University of Guilan, Rasht (Iran, Islamic Republic of); Department of Chemical Engineering, University of Guilan, Rasht (Iran, Islamic Republic of); Ghanadzadeh, A., E-mail: aggilani@guilan.ac.i [Department of Chemistry, Faculty of Science, University of Guilan, Rasht (Iran, Islamic Republic of); Aghajani, Z.; Abbasnejad, S.; Shekarsaraee, S. [Department of Chemistry, Faculty of Science, University of Guilan, Rasht (Iran, Islamic Republic of)

    2010-06-15

    (Liquid + liquid) equilibrium (LLE) data for the ternary mixtures of left bracewater (1) + phosphoric acid (2) + organic solvents (3)right brace were determined at T = 298.2 K and atmospheric pressure. The organic solvents were cyclohexane, 2-methyl-2-butanol (tert-amyl alcohol), and isobutyl acetate. All the investigated systems exhibit Type-1 behaviour of LLE. The immiscibility region was found to be larger for the (water + phosphoric acid + cyclohexane) ternary system. The experimental LLE results were correlated with the NRTL model, and the binary interaction parameters were obtained. The reliability of the experimental tie-line results was tested through the Othmer-Tobias and Bachman correlation equations. Distribution coefficients and separation factors were evaluated over the immiscibility regions and a comparison of the extracting capabilities of the solvents was made with respect to these factors. The experimental results indicate the superiority of cyclohexane as the preferred solvent for the extraction of phosphoric acid from its aqueous solutions.

  15. Rapid DNA extraction of bacterial genome using laundry detergents ...

    African Journals Online (AJOL)

    Genomic DNA extraction from bacterial cells involves processes normally performed in most biological laboratories. Therefore, various methods have been offered, manually and kit, but these methods may be time consuming and costly. In this paper, genomic DNA extraction of Pseudomonas aeruginosa was investigated ...

  16. Determination of thiobencarb in water samples by gas chromatography using a homogeneous liquid-liquid microextraction via flotation assistance procedure

    Directory of Open Access Journals (Sweden)

    H.A. Mashayekhi

    2013-09-01

    Full Text Available Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA coupled with gas chromatography-flame ionization detection (GC-FID was applied for the extraction and determination of thiobencarb in water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added into the extraction cell which contained an appropriate mixture of toluene (as an extraction solvent and acetone (as a homogeneous solvent. By using air flotation, the organic solvent was collected at the conical part of the designed cell. The effect of the different parameters on the efficiency of extraction such as type and volume of extraction and homogeneous solvents, ionic strength and extraction time were studied and optimized. Under the optimal conditions, linearity of the method was in the range of 1.0-200 µg L-1. The relative standard deviations in the real samples varied from 7.8-11.7 % (n = 3. The proposed method was successfully applied to analysis of thiobencarb in the water samples and satisfactory results were obtained.DOI: http://dx.doi.org/10.4314/bcse.v27i3.4

  17. Low density solvent based dispersive liquid-liquid microextraction with gas chromatography-electron capture detection for the determination of cypermethrin in tissues and blood of cypermethrin treated rats.

    Science.gov (United States)

    Mudiam, Mohana Krishna Reddy; Jain, Rajeev; Maurya, Shailendra Kumar; Khan, Haider A; Bandyopadhyay, Sanghamitra; Murthy, R C

    2012-05-01

    A simple and rapid method to determine the cypermethrin (CYP) insecticide in rat tissues (kidney, liver and brain) and blood has been developed for the first time using low density solvent-dispersive liquid-liquid microextraction (LDS-DLLME) followed by gas chromatography-electron capture detector (GC-ECD) analysis. Initially, tissue samples containing CYP were homoginized in acetone. Subsequently, homogenate was mixed with n-hexane (extraction solvent) and the mixture was rapidly injected into water. The upper n-hexane layer was collected in a separate microtube and injected into GC-ECD for analysis. Blood samples were diluted with ultrapure water and subjected to DLLME through similar procedure. Parameters such as type and volume of disperser and extraction solvent, salting out effect and extraction time, which can affect the extraction efficiency of DLLME, were optimized. Method was validated by investigating linearity, precision, recovery, limit of detection (LOD) and quantification (LOQ). LODs in tissue were in the range of 0.043-0.314 ng mg(-1) and for blood it was 8.6 ng mL(-1) with a signal to noise ratio of 3:1. LOQs in tissue were in the range of 0.143-1.03 ng mg(-1) and for blood it was 28.3 ng mL(-1) with a signal to noise ratio of 10:1. Mean recoveries of CYP at three different concentation levels in all the matrices were found to be in the range of 81.6-103.67%. The results show that, LDS-DLLME coupled with GC-ECD offers a simple, rapid and efficient technique for extraction and determination of CYP in rat tissues and blood samples, which in turn would be useful for toxicological studies of CYP. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. An evaluation of cis- and trans-retinol contents in juices using dispersive liquid-liquid microextraction coupled to liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Viñas, Pilar; Bravo-Bravo, María; López-García, Ignacio; Hernández-Córdoba, Manuel

    2013-01-15

    This study describes a method for coupling dispersive liquid-liquid microextraction (DLLME) and normal-phase liquid chromatography (NP-LC) with fluorescence detection for vitamin A determination with the view to developing a new green sample preparation technique. Parameters affecting DLLME, including the nature and volume of both extractant and disperser solvents, salt addition and time and speed of the centrifugation step, were optimized. The sample was saponified according to European Standards to convert all forms of vitamin A to retinol. For microextraction, 8 mL water were placed in a glass tube with conical bottom and the saponified sample consisting of 2 mL of the methanolic extract containing 100 μL tetrachloroethane was rapidly injected by syringe, thereby forming a cloudy solution. Phase separation was performed by centrifugation, and a volume of 20 μL of the sedimented phase was analyzed by NP-LC. The enrichment factor, calculated as the ratio between the slopes of DLLME-LC and direct LC, was 50 ± 3. The matrix effect was evaluated for different juice samples, and it was concluded that sample quantification can be carried out by aqueous calibration when the standards are also submitted to saponification. The proposed method was applied for determining both cis- and trans-retinol isomers in commercial juices of different types. The intraday and interday precisions were lower than 6% in terms of relative standard deviation. The method was validated using two certified reference materials. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Liquid-liquid equilibria of fuel oxygenate + water + hydrocarbon mixtures. 3: Effect of temperature

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, G. [Universitaet Karlsruhe (Germany). Institut fuer Thermische Verfahrenstechnik; Sandler, S.I. [Univ. of Delaware, Newark, DE (United States). Center for Molecular and Engineering Thermodynamics

    1995-09-01

    The authors have measured the ternary liquid-liquid equilibria of water + ethanol mixtures with, separately, 2,2,4-trimethylpentane and toluene at 5 and 40 C, water + tert-amyl alcohol (TAOH) mixtures with, separately, toluene and hexane at 5 and 40 C, and of water + TAOH + pentane mixtures at 5 C. The ethanol-containing systems exhibit type 1 liquid-liquid phase behavior, and the TAOH-containing systems exhibit type 2 behavior. These data, together with the data they have previously reported at 25 C, provide information on how the liquid-liquid equilibria of these systems change as a function of temperature. While the addition of ethanol is found to increase the solubility of hydrocarbons in the aqueous phase, the concentration of the hydrocarbon in the water-rich phase decreases with increasing temperature. With the exception of hydrocarbon in the water-rich phase, the experimental data could be correlated quite well with either the UNIQUAC or NRTL models. For most of the systems considered here the predictions of the phase behavior with the liquid-liquid UNIFAC group-contribution model are only qualitatively correct. However, the liquid-liquid UNIFAC model erroneously predicts type 2 phase behavior to occur for water + ethanol + 2,2,4-trimethylpentane system at 5 C.

  20. Measurement and correlation of (liquid + liquid) equilibrium of the azeotrope (cyclohexane + 2-butanone) with different ionic liquids at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Pereiro, A.B. [Chemical Engineering Department, Vigo University, P.O. Box 36310, Vigo (Spain); Rodri' guez, A. [Chemical Engineering Department, Vigo University, P.O. Box 36310, Vigo (Spain)], E-mail: aroguez@uvigo.es

    2008-08-15

    Experimental densities, speeds of sound, and refractive indices of the binary mixtures of 2-butanone with cyclohexane and OMIM PF{sub 6} (1-methyl-3-octylimidazolium hexafluorophosphate) were determined from T = (293.15 to 303.15) K, since they are necessary to determine the (liquid + liquid) equilibrium. Excess molar volumes, changes of refractive index on mixing, and deviations in isentropic compressibility for the above systems were calculated. Experimental (liquid + liquid) equilibrium of the ternary mixtures {l_brace}cyclohexane + 2-butanone + 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIM PF{sub 6}){r_brace} and (cyclohexane + 2-butanone + OMIM PF{sub 6}) were carried out to assess the suitability of HMIM PF{sub 6} and OMIM PF{sub 6} as azeotrope breaker of the mixture cyclohexane and 2-butanone. Selectivity and distribution ratio values, derived from the tie lines data, were presented in order to analyze the best separation solvent in a liquid extraction process. Experimental (liquid + liquid) equilibrium data were compared with the correlated values obtained by means of the NRTL and UNIQUAC models.

  1. Parallel artificial liquid membrane extraction

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Rasmussen, Knut Einar; Parmer, Marthe Petrine

    2013-01-01

    This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated by an arti......This paper reports development of a new approach towards analytical liquid-liquid-liquid membrane extraction termed parallel artificial liquid membrane extraction. A donor plate and acceptor plate create a sandwich, in which each sample (human plasma) and acceptor solution is separated...... by an artificial liquid membrane. Parallel artificial liquid membrane extraction is a modification of hollow-fiber liquid-phase microextraction, where the hollow fibers are replaced by flat membranes in a 96-well plate format....

  2. Rapid metal extractability tests from polluted mining soils by ultrasound probe sonication and microwave-assisted extraction systems.

    Science.gov (United States)

    García-Salgado, Sara; Quijano, M Ángeles

    2016-12-01

    Ultrasonic probe sonication (UPS) and microwave-assisted extraction (MAE) were used for rapid single extraction of Cd, Cr, Cu, Ni, Pb, and Zn from soils polluted by former mining activities (Mónica Mine, Bustarviejo, NW Madrid, Spain), using 0.01 mol L-1 calcium chloride (CaCl2), 0.43 mol L-1 acetic acid (CH3COOH), and 0.05 mol L-1 ethylenediaminetetraacetic acid (EDTA) at pH 7 as extracting agents. The optimum extraction conditions by UPS consisted of an extraction time of 2 min for both CaCl2 and EDTA extractions and 15 min for CH3COOH extraction, at 30% ultrasound (US) amplitude, whereas in the case of MAE, they consisted of 5 min at 50 °C for both CaCl2 and EDTA extractions and 15 min at 120 °C for CH3COOH extraction. Extractable concentrations were determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The proposed methods were compared with a reduced version of the corresponding single extraction procedures proposed by the Standards, Measurements and Testing Programme (SM&T). The results obtained showed a great variability on extraction percentages, depending on the metal, the total concentration level and the soil sample, reaching high values in some areas. However, the correlation analysis showed that total concentration is the most relevant factor for element extractability in these soil samples. From the results obtained, the application of the accelerated extraction procedures, such as MAE and UPS, could be considered a useful approach to evaluate rapidly the extractability of the metals studied.

  3. Vortex-assisted liquid-liquid-liquid microextraction followed by high performance liquid chromatography for the simultaneous determination of fourteen phenolic acids in honey, iced tea and canned coffee drinks.

    Science.gov (United States)

    Shalash, Marwan; Makahleh, Ahmad; Salhimi, Salizawati Muhamad; Saad, Bahruddin

    2017-11-01

    A vortex-assisted liquid-liquid-liquid microextraction method followed by high performance liquid chromatography-diode array detection for the determination of fourteen phenolic acids (cinnamic, m-coumaric, chlorogenic, syringic, ferulic, o-coumaric, p-coumaric, vanillic, p-hydroxybenzoic, caffeic, 2, 4-dihydroxybenzoic, sinapic, gentisic and gallic acids) in honey, iced tea and canned coffee drink samples has been developed. The separation was achieved using a Poroshell 120-EC-C18 column under a gradient elution at a flow rate of 0.6mLmin-1 and mobile phase composed of methanol and acetic acid (1%, v/v). Under the optimum chromatographic conditions, the fourteen phenolic acids were separated in less than 32min. The extraction was performed using a small volume (400µL) of ternary organic solvents (1-pentanol, propyl acetate and 1-hexanol) dispersed into the aqueous sample (10mL) and assisted by vortex agitation (2500rpm for 45s), the analytes were next back-extracted from the organic solvent using 0.02M KOH (40µL) with vortex speed and time of 2500rpm and 60s, respectively. Under these conditions, enrichment factors of 30-193-fold were achieved. The limits of detection (LODs) were 0.05-0.68µgL-1. Recoveries in honey, iced tea and canned coffee drinks were in the range 72.2-112%. The method was successfully applied for the determination of the phenolic acids in honey, iced tea and canned coffee drinks. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Vortex-assisted low density solvent liquid-liquid microextraction and salt-induced demulsification coupled to high performance liquid chromatography for the determination of five organophosphorus pesticide residues in fruits.

    Science.gov (United States)

    Seebunrueng, Ketsarin; Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2015-01-01

    A simple and rapid microextraction method, vortex-assisted low density solvent liquid-liquid microextraction and salt-induced demulsification (VLLME-SID) coupled to high performance liquid chromatography (HPLC) was developed for the determination of organophosphorus pesticide (OPP) residues in fruits. The studied OPPs were azinphos-methyl, parathion-methyl, fenitrothion, diazinon and chlorpyrifos. For VLLME-SID, a mixture of low density solvents (1-dodecanol and hexane) was used as the extraction solvent under vortex agitation for enhancing dispersion. After complete dispersion, the emulsion was formed and the OPPs were extracted into extraction solvent droplets. Then, the emulsion was quickly broken up into two clear phases after the addition of AlCl3 as a demulsifier. Centrifugation was not required in this procedure. Under the optimal conditions, high enrichment factors (180-282), low limit of detections (LODs) (0.05-1 ng mL(-1)) and good precision (RSD≤7% for retention time and peak area) were obtained. The proposed method was successfully applied to the analysis of OPP residues in fruit samples (watermelon, grape, and cantaloupe). The LODs for samples were in the range 0.0006-0.0015 mg kg(-1) which are below the established EU-MRLs (0.01-0.3 mg kg(-1)). Good recoveries were also obtained (80-104%). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Liquid-liquid equilibrium measurement of ternary system containing β-caryophyllene in the water and 2-propanol mixture

    Science.gov (United States)

    Tetrisyanda, Rizky; Kuswandi, Wibawa, Gede

    2017-01-01

    To obtain a high purity of clove oil, it is needed to separate β-caryophyllene from the oil mixtures.The separation of this component could be obtained by solvent extraction. In this work, liquid-liquid equilibrium (LLE) data were measured for the ternary system of water β-caryophyllene (1) + 2-propanol (2) + water (3) at temperature 303.15 K, 313.15 K and 323.15K under atmospheric pressure. The experimental LLE data were correlated with the NRTL and UNIQUAC models. The reliability of these models is tested by comparison with experimental results. The varied temperatures studied in this work have significant influence to the two-phase area and the solubility of 2-propanol and β-caryophyllene in the aqueous phase.

  6. On the prediction of spray angle of liquid-liquid pintle injectors

    Science.gov (United States)

    Cheng, Peng; Li, Qinglian; Xu, Shun; Kang, Zhongtao

    2017-09-01

    The pintle injector is famous for its capability of deep throttling and low cost. However, the pintle injector has been seldom investigated. To get a good prediction of the spray angle of liquid-liquid pintle injectors, theoretical analysis, numerical simulations and experiments were conducted. Under the hypothesis of incompressible and inviscid flow, a spray angle formula was deduced from the continuity and momentum equations based on a control volume analysis. The formula was then validated by numerical and experimental data. The results indicates that both geometric and injection parameters affect the total momentum ratio (TMR) and then influence the spray angle formed by liquid-liquid pintle injectors. TMR is the pivotal non-dimensional number that dominates the spray angle. Compared with gas-gas pintle injectors, spray angle formed by liquid-liquid injectors is larger, which benefits from the local high pressure zone near the pintle wall caused by the impingement of radial and axial sheets.

  7. Liquid-liquid phase transition and glass transition in a monoatomic model system.

    Science.gov (United States)

    Xu, Limei; Buldyrev, Sergey V; Giovambattista, Nicolas; Stanley, H Eugene

    2010-01-01

    We review our recent study on the polyamorphism of the liquid and glass states in a monatomic system, a two-scale spherical-symmetric Jagla model with both attractive and repulsive interactions. This potential with a parametrization for which crystallization can be avoided and both the glass transition and the liquid-liquid phase transition are clearly separated, displays water-like anomalies as well as polyamorphism in both liquid and glassy states, providing a unique opportunity to study the interplay between the liquid-liquid phase transition and the glass transition. Our study on a simple model may be useful in understanding recent studies of polyamorphism in metallic glasses.

  8. Rapid new methods for paint collection and lead extraction.

    Science.gov (United States)

    Gutknecht, William F; Harper, Sharon L; Winstead, Wayne; Sorrell, Kristen; Binstock, David A; Salmons, Cynthia A; Haas, Curtis; McCombs, Michelle; Studabaker, William; Wall, Constance V; Moore, Curtis

    2009-01-01

    Chronic exposure of children to lead can result in permanent physiological impairment. In adults, it can cause irritability, poor muscle coordination, and nerve damage to the sense organs and nerves controlling the body. Surfaces coated with lead-containing paints are potential sources of exposure to lead. In April 2008, the U.S. Environmental Protection Agency (EPA) finalized new requirements that would reduce exposure to lead hazards created by renovation, repair, and painting activities, which disturb lead-based paint. On-site, inexpensive identification of lead-based paint is required. Two steps have been taken to meet this challenge. First, this paper presents a new, highly efficient method for paint collection that is based on the use of a modified wood drill bit. Second, this paper presents a novel, one-step approach for quantitatively grinding and extracting lead from paint samples for subsequent lead determination. This latter method is based on the use of a high-revolutions per minute rotor with stator to break up the paint into approximately 50 micron-size particles. Nitric acid (25%, v/v) is used to extract the lead in 95% for real-world paints, National Institute of Standards and Technology's standard reference materials, and audit samples from the American Industrial Hygiene Association's Environmental Lead Proficiency Analytical Testing Program. This quantitative extraction procedure, when paired with quantitative paint sample collection and lead determination, may enable the development of a lead paint test kit that will meet the specifications of the final EPA rule.

  9. Low-density solvent-based vortex-assisted surfactant-enhanced emulsification liquid-liquid microextraction and its application.

    Science.gov (United States)

    Yang, Zhong-Hua; Liu, Dong-Hui; Zhao, Wen-ting; Wu, Tong; Zhou, Zhi-Qiang; Wang, Peng

    2013-03-01

    For the first time, the low-density solvent-based vortex-assisted surfactant-enhanced emulsification liquid-liquid microextraction, followed by GC-flame photometric detection has been developed for the determination of eight organophosphorus pesticides in aqueous samples. A small volume of organic extraction solvent (toluene) was dispersed into the aqueous samples by the assistance of surfactant and vortex agitator. The extraction was performed in a special disposable polyethylene pipette, allowing using the reagents with lower density than water as extraction solvents. The influence parameters were systemically investigated and optimized: toluene (30 μL) and Triton X-100 (0.2 mmol/L) were used as the extraction solvent and the surfactant, respectively, and the extraction was performed for 1 min under room temperature without adding sodium chloride. Under the optimum conditions, the validation parameters such as the RSD (n = 6; 2.1-11.3%), LOD (0.005 and 0.05 μg/L), and linear range (0.1-50.0 μg/L with correlation coefficients (0.9958-0.9992) showed the method was satisfying. The proposed method has been successfully applied to the determination of the organophosphorus pesticides in real samples with recoveries between 82.8 and 100.2%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Electromembrane extraction as a rapid and selective miniaturized sample preparation technique for biological fluids

    DEFF Research Database (Denmark)

    Gjelstad, Astrid; Pedersen-Bjergaard, Stig; Seip, Knut Fredrik

    2015-01-01

    of organic solvent, and into an aqueous receiver solution. The extraction is promoted by application of an electrical field, causing electrokinetic migration of the charged analytes. The method has shown to perform excellent clean-up and selectivity from complicated aqueous matrices like biological fluids......This special report discusses the sample preparation method electromembrane extraction, which was introduced in 2006 as a rapid and selective miniaturized extraction method. The extraction principle is based on isolation of charged analytes extracted from an aqueous sample, across a thin film...

  11. Furuncular myiasis: a simple and rapid method for extraction of intact Dermatobia hominis larvae.

    Science.gov (United States)

    Boggild, Andrea K; Keystone, Jay S; Kain, Kevin C

    2002-08-01

    We report a case of furuncular myiasis complicated by Staphylococcus aureus infection and beta-hemolytic streptococcal cellulitis. The Dermatobia hominis larva that caused this lesion could not be extracted using standard methods, including suffocation and application of lateral pressure, and surgery was contraindicated because of cellulitis. The botfly maggot was completely and rapidly extracted with an inexpensive, disposable, commercial venom extractor.

  12. Optimized Dispersive Liquid-Liquid Microextraction Method and High Performance Liquid Chromatography with Ultraviolet Detection for Simultaneous Determination of Sorbic and Benzoic Acids and Evaluation of Contamination of These Preservatives in Iranian Foods.

    Science.gov (United States)

    Javanmardi, Fardin; Arefhosseini, Seyyed Rafie; Ansarin, Masood; Nemati, Mahboob

    2015-01-01

    A rapid, simple, and sensitive dispersive liquid-liquid microextraction procedure followed by HPLC-UV was applied to determine the benzoate and sorbate in foods. The method was optimized for some variables including extraction solvent type and volume, dispersing solvent type and volume, and the effects of salt and pH. Optimum conditions were determined as follows: sample volume, 5 mL; extraction solvent (chloroform) volume, 250 μL; disperser solvent (acetone) volume, 1.2 mL; NaCl amount, 0.75 g/5 mL at pH 4. Sixty samples were analyzed, including 15 doogh, 15 fruit juice, 15 cookie, and 15 tomato paste; benzoic acid was detected in 57 samples (95%) at levels up to 448.1 μg/mL and sorbic acid in 31 samples (51.6%) at levels up to 1369 μg/mL. Under the optimum experimental conditions, the LOD and LOQ were determined as 0.1 and 0.5 μg/mL for benzoate and 0.08 and 0.3 μg/mL for sorbate, respectively. The results showed that these preservatives are commonly used at high levels in yogurt drinks (dooghs) and cookies. Also, the concentration of benzoic acid that was detected in the tomato paste and fruit juice samples was low but may affect children and sensitive persons.

  13. Sequential injection analysis with chemiluminescence detection for rapid monitoring of commercial Calendula officinalis extractions.

    Science.gov (United States)

    Hughes, Rachel R; Scown, David; Lenehan, Claire E

    2015-01-01

    Plant extracts containing high levels of antioxidants are desirable due to their reported health benefits. Most techniques capable of determining the antioxidant activity of plant extracts are unsuitable for rapid at-line analysis as they require extensive sample preparation and/or long analysis times. Therefore, analytical techniques capable of real-time or pseudo real-time at-line monitoring of plant extractions, and determination of extraction endpoints, would be useful to manufacturers of antioxidant-rich plant extracts. To develop a reliable method for the rapid at-line extraction monitoring of antioxidants in plant extracts. Calendula officinalis extracts were prepared from dried flowers and analysed for antioxidant activity using sequential injection analysis (SIA) with chemiluminescence (CL) detection. The intensity of CL emission from the reaction of acidic potassium permanganate with antioxidants within the extract was used as the analytical signal. The SIA-CL method was applied to monitor the extraction of C. officinalis over the course of a batch extraction to determine the extraction endpoint. Results were compared with those from ultra high performance liquid chromatography (UHPLC). Pseudo real-time, at-line monitoring showed the level of antioxidants in a batch extract of Calendula officinalis plateaued after 100 min of extraction. These results correlated well with those of an offline UHPLC study. SIA-CL was found to be a suitable method for pseudo real-time monitoring of plant extractions and determination of extraction endpoints with respect to antioxidant concentrations. The method was applied at-line in the manufacturing industry. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Capillary forces between spherical particles floating at a liquid-liquid interface

    NARCIS (Netherlands)

    Vassileva, Nikolina D.; drs. Vassileva, N.D.; van den Ende, Henricus T.M.; Mugele, Friedrich Gunther; Mellema, J.

    2005-01-01

    We study the capillary forces acting on sub-millimeter particles (0.02-0.6 mm) trapped at a liquid-liquid interface due to gravity-induced interface deformations. An analytical procedure is developed to solve the linearized capillary (Young-Laplace) equation and calculate the forces for an arbitrary

  15. Images reveal that atmospheric particles can undergo liquid-liquid phase separations

    Energy Technology Data Exchange (ETDEWEB)

    You, Yuan; Renbaum-Wolff, Lindsay; Carreras-Sospedra, Marc; Hanna, Sarah; Hiranuma, Naruki; Kamal, Saeid; Smith, Mackenzie L.; Zhang, Xiaolu; Weber, Rodney; Shilling, John E.; Dabdub, Donald; Martin, Scot T.; Bertram, Allan K.

    2012-07-30

    A large fraction of submicron atmospheric particles contains both organic material and inorganic salts. As the relative humidity cycles in the atmosphere, these mixed particles can undergo a range of phase transitions, possibly including liquid-liquid phase separation. If liquid-liquid phase separation occurs, the gas-particle partitioning of atmospheric semi-volatile organic compounds, the scattering and absorption of solar radiation, and the uptake of reactive gas species on atmospheric particles will be affected, with important implications for climate predictions. The actual occurrence of these types of phase transitions within individual atmospheric particles has been considered uncertain, in large part because of the absence of observations for real-world samples. Here, using optical and fluorescence microscopy, we observe the coexistence of two non-crystalline phases in particles generated from real-world samples collected on multiple days in Atlanta, Georgia, and in particles generated in the laboratory using atmospheric conditions. These results reveal that atmospheric particles can undergo liquid-liquid phase separations. Using a box model, we show that liquid-liquid phase separation can result in increased concentrations of gas-phase NO3 and N2O5 in the Atlanta region, due to decreased particle uptake of N2O5.

  16. Jet-mixing of initially-stratified liquid-liquid pipe flows: experiments and numerical simulations

    Science.gov (United States)

    Wright, Stuart; Ibarra-Hernandes, Roberto; Xie, Zhihua; Markides, Christos; Matar, Omar

    2016-11-01

    Low pipeline velocities lead to stratification and so-called 'phase slip' in horizontal liquid-liquid flows due to differences in liquid densities and viscosities. Stratified flows have no suitable single point for sampling, from which average phase properties (e.g. fractions) can be established. Inline mixing, achieved by static mixers or jets in cross-flow (JICF), is often used to overcome liquid-liquid stratification by establishing unstable two-phase dispersions for sampling. Achieving dispersions in liquid-liquid pipeline flows using JICF is the subject of this experimental and modelling work. The experimental facility involves a matched refractive index liquid-liquid-solid system, featuring an ETFE test section, and experimental liquids which are silicone oil and a 51-wt% glycerol solution. The matching then allows the dispersed fluid phase fractions and velocity fields to be established through advanced optical techniques, namely PLIF (for phase) and PTV or PIV (for velocity fields). CFD codes using the volume of a fluid (VOF) method are then used to demonstrate JICF breakup and dispersion in stratified pipeline flows. A number of simple jet configurations are described and their dispersion effectiveness is compared with the experimental results. Funding from Cameron for Ph.D. studentship (SW) gratefully acknowledged.

  17. A free energy study of the liquid-liquid phase transition of the Jagla ...

    Indian Academy of Sciences (India)

    Francesco Ricci

    Abstract. A fundamental understanding of pure-component liquid-liquid phase separation in network-forming fluids remains an open challenge. While considerable progress has been recently made in demonstrating the existence of such a phase transition in some models via rigorous free energy calculations, it remains ...

  18. Indication of liquid-liquid phase transition in CuZr-based melts

    DEFF Research Database (Denmark)

    Zhou, C.; Hu, L.N.; Sun, Q.J.

    2013-01-01

    We study the dynamic behavior of CuZr-based melts well above the liquidus temperature. The results show a discontinuous change in viscosity during cooling, which is attributed to an underlying liquid-liquid phase transition (LLPT) in these melts. The LLPT is further verified by thermodynamic...

  19. Elastic properties of surfactant monolayers at liquid-liquid interfaces: A molecular dynamics study

    DEFF Research Database (Denmark)

    Laradji, Mohamed; Mouritsen, Ole G.

    2000-01-01

    Using a simple molecular model based on the Lennard-Jones potential, we systematically study the elastic properties of liquid-liquid interfaces containing surfactant molecules by means of extensive and large-scale molecular dynamics simulations. The main elastic constants of the interface, corres...

  20. Thermally safe operation of a cooled semi-batch reactor: slow liquid-liquid reactions

    NARCIS (Netherlands)

    Steensma, M.; Westerterp, K.R.

    1988-01-01

    Thermally safe operation of a semi-batch reactor (SBR) implies that conditions leading to strong accumulation of unreacted reactants must be avoided. All thermal responses of a SBR, in which a slow liquid-liquid reaction takes place, can be represented in a diagram with the kinetics, cooling

  1. Determination of atranol and chloroatranol in perfumes using simultaneous derivatization and dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry.

    Science.gov (United States)

    López-Nogueroles, Marina; Chisvert, Alberto; Salvador, Amparo

    2014-05-15

    A new analytical method based on simultaneous derivatization and dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS), for the determination of the allergenic compounds atranol and chloroatranol in perfumes, is presented. Derivatization of the target analytes by means of acetylation with anhydride acetic in carbonate buffer was carried out. Thereby volatility and detectability were increased for improved GC-MS sensitivity. In addition, extractability by DLLME was also enhanced due to a less polar character of the solutes. A liquid-liquid extraction was performed before DLLME to clean up the sample and to obtain an aqueous sample solution, free of the low polar matrix from the essential oils, as donor phase. Different parameters, such as the nature and volume of both the extraction and disperser solvents, the ionic strength of the aqueous donor phase or the effect of the derivatization reagent volume, were optimized. Under the selected conditions (injection of a mixture of 750μL of acetone as disperser solvent, 100μL of chloroform as extraction solvent and 100μL of anhydride acetic as derivatization reagent) the figures of merit of the proposed method were evaluated. Limits of detection in the low ngmL(-1) range were obtained. Matrix effect was observed in real perfume samples and thus, standard addition calibration is recommended. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. A new coupling of spectrophotometric determination with ultrasound-assisted emulsification dispersive liquid-liquid microextraction of trace silver

    Science.gov (United States)

    Wen, Xiaodong; Kong, Lamei; Chen, Meihui; Deng, Qingwen; Zhao, Xia; Guo, Jie

    2012-11-01

    In this work, a new coupling of spectrophotometric determination with preconcentration method named as ultrasound-assisted emulsification dispersive liquid-liquid microextraction (UAE-DLLME) for trace silver was firstly established. Disperser solvent in traditional DLLME was substituted by ultrasound-assisted emulsification, which could afford more effective emulsification and make the extraction method greener. The extraction was accomplished efficiently in only 3 min during ultrasound-assisted emulsification. Compared to traditional DLLME, the established pretreatment was simpler, greener and more effective. The UAE-DLLME technique was effectively coupled with ordinary spectrophotometer to improve the analytical performance and expand the application of spectrophotometric determination. The factors influencing UAE-DLLME, such as concentration of chelating agent, kind and volume of extractant, pH, conditions of phase separation, ultrasound extraction time and instrumental conditions, were studied in detail. Under the optimal conditions, the limit of detection (LOD) for silver was 0.45 μg L-1, with sensitivity enhancement factor (EF) of 35. The established method was applied to the determination of trace silver in real and certified reference samples with satisfactory analytical results.

  3. Dispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry

    Directory of Open Access Journals (Sweden)

    Teslima Daşbaşı

    2016-01-01

    Full Text Available A dispersive liquid-liquid microextraction method for the determination of bismuth in various samples by flame atomic absorption spectrometry is described. In this method, crystal violet was used as counter positive ion for BiCl4- complex ion, chloroform as extraction solvent, and ethanol as disperser solvent. The analytical parameters that may affect the extraction efficiency like acidity of sample, type and amount of extraction and disperser solvents, amount of ligand, and extraction time were studied in detail. The effect of interfering ions on the analyte recovery was also investigated. The calibration graph was linear in the range of 0.040–1.00 mg L−1 with detection limit of 4.0 μg L−1 (n=13. The precision as relative standard deviation was 3% (n=11, 0.20 mg L−1 and the enrichment factor was 74. The developed method was applied successfully for the determination of bismuth in various water, pharmaceutical, and cosmetic samples and the certified reference material (TMDA-64 lake water.

  4. Dispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry

    Science.gov (United States)

    Daşbaşı, Teslima; Kartal, Şenol; Saçmacı, Şerife; Ülgen, Ahmet

    2016-01-01

    A dispersive liquid-liquid microextraction method for the determination of bismuth in various samples by flame atomic absorption spectrometry is described. In this method, crystal violet was used as counter positive ion for BiCl4 − complex ion, chloroform as extraction solvent, and ethanol as disperser solvent. The analytical parameters that may affect the extraction efficiency like acidity of sample, type and amount of extraction and disperser solvents, amount of ligand, and extraction time were studied in detail. The effect of interfering ions on the analyte recovery was also investigated. The calibration graph was linear in the range of 0.040–1.00 mg L−1 with detection limit of 4.0 μg L−1 (n = 13). The precision as relative standard deviation was 3% (n = 11, 0.20 mg L−1) and the enrichment factor was 74. The developed method was applied successfully for the determination of bismuth in various water, pharmaceutical, and cosmetic samples and the certified reference material (TMDA-64 lake water). PMID:26881186

  5. Determination of parabens in beverage samples by dispersive liquid-liquid microextraction based on solidification of floating organic droplet.

    Science.gov (United States)

    Hou, Fang; Deng, Xiaoying; Jiang, Xinyu; Yu, Jingang

    2014-01-01

    A simple and efficient method for dispersive liquid-liquid microextraction of methylparaben, ethylparaben, propylparaben and butylparaben in real beverage samples was developed. It is making use of solidified floating organic droplets of 1-dodecanol which has low density and a proper melting point. Parameters influencing the extraction efficiency, such as the type of extraction and dispersive solvent, the volume of extraction and dispersive solvent, salt effect, pH, extraction time, were optimized and resulted in enrichment factors (EFs) of 84 for methylparaben, 103 for ethylparaben, 115 for propylparaben and 126 for butylparaben. The limits of detection for parabens were 1.52, 1.06, 0.32 and 0.17 ng/mL, respectively. Excellent linearity with coefficients of correlation from 0.9970 to 0.9997 was observed in the concentration range of 5-1,000 ng/mL. The repeatability of the proposed method expressed as relative standard deviations (RSDs) ranged from 2.54 to 3.89% (n = 5). The relative recoveries for parabens in beverage samples were good and in the ranges of 89.8-109.9, 90.2-107.3, 90.9-101.7 and 92.3-118.1%, respectively. Thus, the proposed method has excellent potential for the determination of parabens in beverage samples. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Simulations of electrolytes at the liquid-liquid interface and of lanthanide cations complexes in gas phase; Simulations d'electrolytes a l'interface liquide/liquide et de complexes de cations lanthanides en phase gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Berny, F

    2000-07-01

    Two processes related to liquid/liquid extraction of ions by extractant molecules were studied: the ion approach at the interface and the ion complexation by ligands. In the first part, the behaviour of salts at the chloroform/water interface was simulated by molecular dynamics. The aim was to understand the way these salts ions approach the interface in order to be extracted. Some ions are repelled by the interface (K{sup +}, Cl{sup -}, UO{sub 2}{sup 2+}, Na{sup +}, NO{sub 3}{sup -}) whereas others adsorb (amphiphilic molecules and also ClO{sub 4}{sup -}, SCN{sup -}, guanidinium Gu{sup +} and picrate Pic{sup -}). The surface-active counter-ions make the ion approach at the interface easier. In a perfectly homogeneous mixture of the two solvents (water and chloroform) de-mixing, the ions seem to influence the phases separation rate. Nitric acid which is known to favour liquid/liquid extraction reveals strong adsorption at the interface in its neutral form and a smaller one in its ionic form (H{sub 3}O{sup +}/NO{sub 3}{sup -}). HNO{sub 3} and H{sub 3}O{sup +} display particular orientations at the interface: hydrogen atoms are pointing in the direction of the water slab. The nature of the organic phase can also influence the ion approach at the interface. For example, Gu{sup +} and Pic{sup -} adsorb much less at the supercritical CO{sub 2}/water interface than at the chloroform/water interface. In the second part, complexes of La{sup 3+}, Eu{sup 3+} and Yb{sup 3+} with ligands such as amide, urea, thio-amide, thiourea were studied by quantum mechanics. Our calculations show that cation-ligand interactions depend on the nature of substituents on ligands, on the presence of counter-ions or on the number of ligands in the complex. Sulfur compounds seem to less interact with cations than oxygen compounds. Ureas interact as much as amides and are potentially good ligands. (author)

  7. Sensitive determination of methadone in human serum and urine by dispersive liquid-liquid microextraction based on the solidification of a floating organic droplet followed by HPLC-UV.

    Science.gov (United States)

    Taheri, Salman; Jalali, Fahimeh; Fattahi, Nazir; Jalili, Ronak; Bahrami, Gholamreza

    2015-10-01

    Dispersive liquid-liquid microextraction based on solidification of floating organic droplet was developed for the extraction of methadone and determination by high-performance liquid chromatography with UV detection. In this method, no microsyringe or fiber is required to support the organic microdrop due to the usage of an organic solvent with a low density and appropriate melting point. Furthermore, the extractant droplet can be collected easily by solidifying it at low temperature. 1-Undecanol and methanol were chosen as extraction and disperser solvents, respectively. Parameters that influence extraction efficiency, i.e. volumes of extracting and dispersing solvents, pH, and salt effect, were optimized by using response surface methodology. Under optimal conditions, enrichment factor for methadone was 134 and 160 in serum and urine samples, respectively. The limit of detection was 3.34 ng/mmL in serum and 1.67 ng/mL in urine samples. Compared with the traditional dispersive liquid-liquid microextraction, the proposed method obtained lower limit of detection. Moreover, the solidification of floating organic solvent facilitated the phase transfer. And most importantly, it avoided using high-density and toxic solvents of traditional dispersive liquid-liquid microextraction method. The proposed method was successfully applied to the determination of methadone in serum and urine samples of an addicted individual under methadone therapy. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Rapid Solid-Liquid Dynamic Extraction (RSLDE): a New Rapid and Greener Method for Extracting Two Steviol Glycosides (Stevioside and Rebaudioside A) from Stevia Leaves.

    Science.gov (United States)

    Gallo, Monica; Vitulano, Manuela; Andolfi, Anna; DellaGreca, Marina; Conte, Esterina; Ciaravolo, Martina; Naviglio, Daniele

    2017-06-01

    Stevioside and rebaudioside A are the main diterpene glycosides present in the leaves of the Stevia rebaudiana plant, which is used in the production of foods and low-calorie beverages. The difficulties associated with their extraction and purification are currently a problem for the food processing industries. The objective of this study was to develop an effective and economically viable method to obtain a high-quality product while trying to overcome the disadvantages derived from the conventional transformation processes. For this reason, extractions were carried out using a conventional maceration (CM) and a cyclically pressurized extraction known as rapid solid-liquid dynamic extraction (RSLDE) by the Naviglio extractor (NE). After only 20 min of extraction using the NE, a quantity of rebaudioside A and stevioside equal to 1197.8 and 413.6 mg/L was obtained, respectively, while for the CM, the optimum time was 90 min. From the results, it can be stated that the extraction process by NE and its subsequent purification developed in this study is a simple, economical, environmentally friendly method for producing steviol glycosides. Therefore, this method constitutes a valid alternative to conventional extraction by reducing the extraction time and the consumption of toxic solvents and favouring the use of the extracted metabolites as food additives and/or nutraceuticals. As an added value and of local interest, the experiment was carried out on stevia leaves from the Benevento area (Italy), where a high content of rebaudioside A was observed, which exhibits a sweet taste compared to stevioside, which has a significant bitter aftertaste.

  9. An efficient, cost effective, sensing behaviour liquid-liquid extraction and spectrophotometric determination of copper(II) incorporated with 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole: Analysis of food samples, leafy vegetables, fertilizers and environmental samples

    Science.gov (United States)

    Barache, Umesh B.; Shaikh, Abdul B.; Lokhande, Tukaram N.; Kamble, Ganesh S.; Anuse, Mansing A.; Gaikwad, Shashikant H.

    2018-01-01

    The aim of the present work is to develop an efficient, simple and selective moreover cost-effective method for the extractive spectrophotometric determination of copper(II) by using the Schiff base 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole [CBIMMT]. This chromogenic reagent forms a yellow coloured complex with copper(II) in acetate buffer at pH 4.2. The copper(II) complex with ligand is instantly extracted into chloroform and shows a maximum absorbance at 414 nm which remains stable for > 48 h. The composition of extracted complex is found to be 1:2 [copper(II): reagent] which was ascertained using Job's method of continuous variation, mole ratio method and slope ratio method. Under optimal conditions, the copper(II) complex in chloroform adheres to Beer's law up to 17.5 μg mL- 1 of copper(II). The optimum concentration range obtained from Ringbom's plot is from 5 μg mL- 1 to 17.5 μg mL- 1. The molar absorptivity, Sandell's sensitivity and enrichment factor of the extracted copper(II) chelate are 0.33813 × 104 L mol- 1 cm- 1, 0.01996 μg cm- 2 and 2.49 respectively. In the extraction of copper(II), several affecting factors including the solution pH, ligand concentration, equilibrium time, effect of foreign ions are optimized. The interfering effects of various cations and anions were also studied and use of masking agents enhances the selectivity of the method. The chromogenic sulphur containing reagent, 4-(4‧-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole has been synthesized in a single step with high purity and yield. The synthesized reagent has been successfully applied first time for determination of copper(II). The reagent forms stable chelate with copper(II) in buffer medium instantly and quantitatively extracted in chloroform within a minute. The method is successfully applied for the determination of copper(II) in various synthetic mixtures, complexes, fertilizers, environmental samples such as food samples

  10. An efficient, cost effective, sensing behaviour liquid-liquid extraction and spectrophotometric determination of copper(II) incorporated with 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole: Analysis of food samples, leafy vegetables, fertilizers and environmental samples.

    Science.gov (United States)

    Barache, Umesh B; Shaikh, Abdul B; Lokhande, Tukaram N; Kamble, Ganesh S; Anuse, Mansing A; Gaikwad, Shashikant H

    2018-01-15

    The aim of the present work is to develop an efficient, simple and selective moreover cost-effective method for the extractive spectrophotometric determination of copper(II) by using the Schiff base 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole [CBIMMT]. This chromogenic reagent forms a yellow coloured complex with copper(II) in acetate buffer at pH4.2. The copper(II) complex with ligand is instantly extracted into chloroform and shows a maximum absorbance at 414nm which remains stable for >48h. The composition of extracted complex is found to be 1:2 [copper(II): reagent] which was ascertained using Job's method of continuous variation, mole ratio method and slope ratio method. Under optimal conditions, the copper(II) complex in chloroform adheres to Beer's law up to 17.5μgmL(-1) of copper(II). The optimum concentration range obtained from Ringbom's plot is from 5μgmL(-1) to 17.5μgmL(-1). The molar absorptivity, Sandell's sensitivity and enrichment factor of the extracted copper(II) chelate are 0.33813×10(4)Lmol(-1)cm(-1), 0.01996μgcm(-2) and 2.49 respectively. In the extraction of copper(II), several affecting factors including the solution pH, ligand concentration, equilibrium time, effect of foreign ions are optimized. The interfering effects of various cations and anions were also studied and use of masking agents enhances the selectivity of the method. The chromogenic sulphur containing reagent, 4-(4'-chlorobenzylideneimino)-3-methyl-5-mercapto-1, 2, 4-triazole has been synthesized in a single step with high purity and yield. The synthesized reagent has been successfully applied first time for determination of copper(II). The reagent forms stable chelate with copper(II) in buffer medium instantly and quantitatively extracted in chloroform within a minute. The method is successfully applied for the determination of copper(II) in various synthetic mixtures, complexes, fertilizers, environmental samples such as food samples, leafy

  11. Determination of calcium stearate in polyolefin samples by gas chromatographic technique after performing dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Ranji, Ali; Ghorbani Ravandi, Mahboobeh; Farajzadeh, Mir Ali

    2008-05-01

    In this study, a gas chromatographic method is presented for the determination of calcium stearate after its conversion to stearic acid in a polymeric matrix. A solution of hydrochloric acid in 2-propanol is used as an extracting solvent of calcium stearate and its converter to stearic acid. For stearic acid preconcentration before its injection to a separation system, a recently presented extraction method, dispersive liquid-liquid microextraction, using carbon tetrachloride as an extracting solvent is used. Finally, 1 microL of the organic phase collected at the bottom of a conical test tube after centrifuging is injected into a gas chromatograph (GC) for quantification. This method has a relatively broad linear dynamic range (50 - 2000 mg/L) with a limit of detection (LOD) of 15 mg/L for stearic acid in solution. The LOD of the proposed method in a polymeric sample using 10 mg of polymer is 60 ppm as calcium stearate. Some effective parameters, such as the time and temperature of heating, the concentration of hydrochloric acid and the volume of distilled water, were studied.

  12. Hollow-Fibre-Supported Dispersive Liquid-Liquid Microextraction for Determination of Atrazine and Triclosan in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Thabiso Letseka

    2017-01-01

    Full Text Available We report the application of the dispersive liquid-liquid microextraction coupled to hollow-fibre membrane-assisted liquid-phase microextraction and its application for extraction of atrazine and triclosan. Under optimum conditions, namely, 25 μL of a 1 : 4 chlorobenzene : ethyl acetate mixture dispersed in 1 mL of aqueous sample, 10% (m/v NaCl, a magnetic stirrer speed at 600 rpm, and 10 minutes’ extraction time with toluene-filled fibre as the acceptor phase, the method demonstrates sufficient figures of merit. These include linearity (R2 ≥ 0.9975, intravial precision (%RSD ≤ 7.6, enrichment factors (127 and 142, limits of detection (0.0081 and 0.0169 µg/mL, and recovery from river water and sewerage (96–101%. The relatively high detection limits are attributed to the flame ionization detector which is less preferred than a mass spectrometer in trace analyses. This is the first report of a homogenous mixture of the dispersed organic solvent in aqueous solutions and its employment in extraction of organic compounds from aqueous solutions. It therefore adds yet another candidate in the pool of miniaturised solvent microextraction techniques.

  13. Dispersive liquid-liquid microextraction combined with capillary electrophoresis and time-of-flight mass spectrometry for urine analysis.

    Science.gov (United States)

    Kohler, Isabelle; Schappler, Julie; Sierro, Tatiana; Rudaz, Serge

    2013-01-25

    The combination of dispersive liquid-liquid microextraction (DLLME) with capillary electrophoresis (CE) and a time-of-flight mass spectrometer (TOF-MS) was evaluated for the toxicological screening in urine samples. A methodology based on design of experiments (DOE) was implemented to increase the extraction efficiency. Dichloromethane and isopropanol were selected as the extraction and dispersing solvents, respectively. Seven factors for DLLME were screened with the help of a Plackett-Burmann DOE using two model compounds before fine investigation of the important parameters to maximise the compound extraction. These experiments were performed in the CE-UV configuration to overcome potential MS matrix effects. The performance of the entire procedure was then evaluated using CE-ESI-TOF-MS. With a preconcentration factor of more than 130, the highly sensitive DLLME-CE-ESI-TOF-MS method allowed for the detection of 30 toxicological compounds (i.e., amphetamines and their derivatives, opiates, cocaine and its metabolites and pharmaceuticals) in urine with limits of detection in the sub-ng/mL level and was used to analyse real toxicological samples. The combination of DLLME and CE was particularly attractive because of the small amount of organic solvents required. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Combination of dispersive liquid-liquid microextraction and solid-phase microextraction: An efficient hyphenated sample preparation method.

    Science.gov (United States)

    Jafari, Mohammad T; Saraji, Mohammad; Mossaddegh, Mehdi

    2016-09-30

    Two well-known microextraction methods, dispersive liquid-liquid microextraction (DLLME) and solid-phase microextraction (SPME), were combined, resulting in as an encouraging method. The method, named DLLME-SPME, was performed based on total vaporization technique. For the DLLME step, 1,1,2,2-tetrachloroethane and acetonitrile were used as extraction and disperser solvents, respectively. Halloysite nanotubes-titanium dioxide was used as the fiber coating in the SPME step. The method was applied for the extraction of diazinon and parathion (as the test compounds) in environmental water samples and fruit juices, and gas chromatography-corona discharge ion mobility spectrometry was used as the determination apparatus. Desorption temperature and time, extraction temperature and time, and the volume of the extracting solvent in the DLLME step were optimized as the effective parameters on the extraction efficiency. The relative standard deviations (RSDs) of intra-day were found to be 4-7% and 6-8% for diazinon and parathion, respectively. Also, the RSDs of inter-day were 7-9% and 8-10% for diazinon and parathion, respectively. The limits of quantification and detection were obtained to be 0.015 and 0.005μgL(-1) for diazinon, and 0.020 and 0.007μgL(-1) for parathion. A good linearity range (r(2)˃0.993) was obtained in the range of 0.015-3.000 and 0.020-3.000μgL(-1) for diazinon and parathion, respectively. The high enrichment factors were obtained as 3150 and 2965 for diazinon and parathion, respectively. This method showed high sensitivity with good recovery values (between 87 and 99%) for the extraction of target analytes in the real samples. Overall, the results revealed that the developed DLLME-SPME method had better extraction efficiency than DLLME and SPME alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A rapid direct solvent extraction method for the extraction of 2-dodecylcyclobutanone from irradiated ground beef patties using acetonitrile.

    Science.gov (United States)

    Hijaz, Faraj; Kumar, Amit; Smith, J Scott

    2010-08-01

    The amount of irradiated beef in the U.S. market is growing, and a reliable, rapid method is needed to detect irradiated beef and quantify the irradiation dose. The official analytical method (BS EN 1785 2003) that has been adopted by the European Union is time consuming. The objective of this study was to develop a rapid method for the analysis of 2-dodecylcyclobutanone (2-DCB) in irradiated beef. A 5 g sample of commercially irradiated ground beef patty (90/10) was extracted with n-hexane using a Soxhlet apparatus or with acetonitrile via direct solvent extraction. The Soxhlet hexane extract was evaporated to dryness, and the sample was dissolved in a mixture of ethyl acetate and acetonitrile (1:1). The defatted extract was purified with a 1 g silica cartridge. Another 5 g aliquot of the same patty was mixed with 50 mL acetonitrile and either blended for 1 min with a hand blender or crushed for 10 min with a glass rod. The extraction procedure was repeated 3 times, and the acetonitrile was collected and evaporated to dryness. Eluants from both methods were concentrated under nitrogen and injected into a gas chromatography-mass spectrometry. The 2-DCB concentration in the commercial samples was 0.031 +/- 0.0026 ppm (n = 5) for the Soxhlet method and 0.031 +/- 0.0025 ppm (n = 10) for direct solvent extraction. Recovery of 2-DCB from spiked beef samples in the direct solvent extraction method was 93.2 +/- 9.0% (n = 7). This study showed that the direct solvent extraction method is simple and as efficient and reproducible as the Soxhlet method.

  16. Evaluation of antimicrobial activity of selected plant extracts by rapid XTT colorimetry and bacterial enumeration.

    Science.gov (United States)

    Al-Bakri, Amal G; Afifi, Fatma U

    2007-01-01

    The aim of this study was to screen and evaluate the antimicrobial activity of indigenous Jordanian plant extracts, dissolved in dimethylsulfoxide, using the rapid XTT assay and viable count methods. XTT rapid assay was used for the initial screening of antimicrobial activity for the plant extracts. Antimicrobial activity of potentially active plant extracts was further assessed using the "viable plate count" method. Four degrees of antimicrobial activity (high, moderate, weak and inactive) against Bacillus subtilis, Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa, respectively, were recorded. The plant extracts of Hypericum triquetrifolium, Ballota undulata, Ruta chalepensis, Ononis natrix, Paronychia argentea and Marrubium vulgare had shown promising antimicrobial activity. This study showed that while both XTT and viable count methods are comparable when estimating the overall antimicrobial activity of experimental substances, there is no strong linear correlation between the two methods.

  17. Methods to control phase inversions and enhance mass transfer in liquid-liquid dispersions

    Science.gov (United States)

    Tsouris, Constantinos; Dong, Junhang

    2002-01-01

    The present invention is directed to the effects of applied electric fields on liquid-liquid dispersions. In general, the present invention is directed to the control of phase inversions in liquid-liquid dispersions. Because of polarization and deformation effects, coalescence of aqueous drops is facilitated by the application of electric fields. As a result, with an increase in the applied voltage, the ambivalence region is narrowed and shifted toward higher volume fractions of the dispersed phase. This permits the invention to be used to ensure that the aqueous phase remains continuous, even at a high volume fraction of the organic phase. Additionally, the volume fraction of the organic phase may be increased without causing phase inversion, and may be used to correct a phase inversion which has already occurred. Finally, the invention may be used to enhance mass transfer rates from one phase to another through the use of phase inversions.

  18. Development, Fabrication, and Testing of a Liquid/Liquid Microchannel Heat Exchanger for Constellation Spacecrafts

    Science.gov (United States)

    Hawkins-Reynolds, Ebony; Le, Hung; Stephan, Ryan

    2010-01-01

    Microchannel technology can be incorporated into heat exchanger designs to decrease the mass and volume of space hardware. The National Aeronautics and Space Administration at the Johnson Space Center (NASA JSC) partnered with Pacific Northwest National Laboratories (PNNL) to develop a liquid/liquid microchannel heat exchanger that has significant mass and volume savings without sacrificing thermal and pressure drop performance. PNNL designed the microchannel heat exchanger to the same performance design requirements of a conventional plate and fin liquid/liquid heat exchanger; 3 kW duty with inlet temperatures of 26 C and 4 C. Both heat exchangers were tested using the same test parameters on a test apparatus and performance data compared.

  19. Liquid-Liquid Phase Transition and Glass Transition in a Monoatomic Model System

    Directory of Open Access Journals (Sweden)

    Nicolas Giovambattista

    2010-12-01

    Full Text Available We review our recent study on the polyamorphism of the liquid and glass states in a monatomic system, a two-scale spherical-symmetric Jagla model with both attractive and repulsive interactions. This potential with a parametrization for which crystallization can be avoided and both the glass transition and the liquid-liquid phase transition are clearly separated, displays water-like anomalies as well as polyamorphism in both liquid and glassy states, providing a unique opportunity to study the interplay between the liquid-liquid phase transition and the glass transition. Our study on a simple model may be useful in understanding recent studies of polyamorphism in metallic glasses.

  20. Theoretical background and the flow fields in downhole liquid-liquid hydrocyclone (LLHC

    Directory of Open Access Journals (Sweden)

    Osei Harrison

    2014-07-01

    Full Text Available Hydrocyclone system for downhole oil-water separation provides an effective technique of enhancing the economic viability of higher water-cut wells while at the same time reducing the risk of environmental pollution. This paper describes the hydrodynamics of the liquid-liquid hydrocyclones and the flow fields within it are paramount for achieving successful separation process. Some of the important hydrodynamic flow phenomenon within the liquid-liquid hydrocyclone and how they influence the separation efficiency of water/oil was analyzed through analytical solution. The properties of the liquids were based on Bayan offshore field measured properties. The results indicated that there are two swirling zones separated by stagnant flow field. The inner is the light liquid zone, while the outer is the heavy liquid zone.

  1. Microscopic evidence for liquid-liquid separation in supersaturated CaCO3 solutions.

    Science.gov (United States)

    Wallace, Adam F; Hedges, Lester O; Fernandez-Martinez, Alejandro; Raiteri, Paolo; Gale, Julian D; Waychunas, Glenn A; Whitelam, Stephen; Banfield, Jillian F; De Yoreo, James J

    2013-08-23

    Recent experimental observations of the onset of calcium carbonate (CaCO3) mineralization suggest the emergence of a population of clusters that are stable rather than unstable as predicted by classical nucleation theory. This study uses molecular dynamics simulations to probe the structure, dynamics, and energetics of hydrated CaCO3 clusters and lattice gas simulations to explore the behavior of cluster populations before nucleation. Our results predict formation of a dense liquid phase through liquid-liquid separation within the concentration range in which clusters are observed. Coalescence and solidification of nanoscale droplets results in formation of a solid phase, the structure of which is consistent with amorphous CaCO3. The presence of a liquid-liquid binodal enables a diverse set of experimental observations to be reconciled within the context of established phase-separation mechanisms.

  2. Liquid-Liquid equilibria of the water-acetic acid-butyl acetate system

    Directory of Open Access Journals (Sweden)

    Ince E.

    2002-01-01

    Full Text Available Experimental liquid-liquid equilibria of the water-acetic acid-butyl acetate system were studied at temperatures of 298.15± 0.20, 303.15± 0.20 and 308.15± 0.20 K. Complete phase diagrams were obtained by determining solubility and tie-line data. The reliability of the experimental tie-line data was ascertained by using the Othmer and Tobias correlation. The UNIFAC group contribution method was used to predict the observed ternary liquid-liquid equilibrium (LLE data. It was found that UNIFAC group interaction parameters used for LLE did not provide a good prediction. Distribution coefficients and separation factors were evaluated for the immiscibility region.

  3. Liquid-liquid separation in solutions of normal and sickle cell hemoglobin

    Science.gov (United States)

    Galkin, Oleg; Chen, Kai; Nagel, Ronald L.; Elison Hirsch, Rhoda; Vekilov, Peter G.

    2002-06-01

    We show that in solutions of human hemoglobin (Hb)oxy- and deoxy-Hb A or Sof near-physiological pH, ionic strength, and Hb concentration, liquid-liquid phase separation occurs reversibly and reproducibly at temperatures between 35 and 40°C. In solutions of deoxy-HbS, we demonstrate that the dense liquid droplets facilitate the nucleation of HbS polymers, whose formation is the primary pathogenic event for sickle cell anemia. In view of recent results that shifts of the liquid-liquid separation phase boundary can be achieved by nontoxic additives at molar concentrations up to 30 times lower than the protein concentrations, these findings open new avenues for the inhibition of the HbS polymerization.

  4. Determination of liquid-liquid critical point composition using 90∘ laser light scattering

    Science.gov (United States)

    Williamson, J. Charles; Brown, Allison M.; Helvie, Elise N.; Dean, Kevin M.

    2016-04-01

    Despite over a century of characterization efforts, liquid-liquid critical point compositions are difficult to identify with good accuracy. Reported values vary up to 10% for even well-studied systems. Here, a technique is presented for high-precision determination of the critical composition of a partially miscible binary liquid system. Ninety-degree laser light-scattering intensities from single-phase samples are analyzed using an equation derived from nonclassical power laws and the pseudospinodal approximation. Results are reported for four liquid-liquid systems (aniline + hexane, isobutyric acid + water, methanol + cyclohexane, and methanol + carbon disulfide). Compared to other methods, the 90∘ light-scattering approach has a strong dependence on composition near the critical point, is less affected by temperature fluctuations, and is insensitive to the presence of trace impurities in the samples. Critical compositions found with 90∘ light scattering are precise to the parts-per-thousand level and show long-term reproducibility.

  5. Parasitic slow extraction of extremely weak beam from a high-intensity proton rapid cycling synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Ye [University of Science and Technology of China, Hefei, Anhui 230029 (China); Institute of High Energy Physics, CAS, Yuquan Road 19B, Beijing 100049 (China); Tang, Jingyu, E-mail: tangjy@ihep.ac.cn [University of Science and Technology of China, Hefei, Anhui 230029 (China); Institute of High Energy Physics, CAS, Yuquan Road 19B, Beijing 100049 (China); Yang, Zheng; Jing, Hantao [Institute of High Energy Physics, CAS, Yuquan Road 19B, Beijing 100049 (China)

    2014-02-11

    This paper proposes a novel method to extract extremely weak beam from a high-intensity proton rapid cycling synchrotron (RCS) in the parasitic mode, while maintaining the normal fast extraction. The usual slow extraction method from a synchrotron by employing third-order resonance cannot be applied in a high-intensity RCS due to a very short flat-top at the extraction energy and the strict control on beam loss. The proposed parasitic slow extraction method moves the beam to scrape a scattering foil prior to the fast beam extraction by employing either a local orbit bump or momentum deviation or their combination, so that the halo part of the beam will be scattered. A part of the scattered particles will be extracted from the RCS and guided to the experimental area. The slow extraction process can last about a few milliseconds before the beam is extracted by the fast extraction system. The method has been applied to the RCS of China Spallation Neutron Source. With 1.6 GeV in the extraction energy, 62.5 μA in the average current and 25 Hz in the repetition rate for the RCS, the proton intensity by the slow extraction method can be up to 2×10{sup 4} protons per cycle or 5×10{sup 5} protons per second. The extracted beam has also a good time structure of approximately uniform in a spill which is required for many applications such as detector tests. Detailed studies including the scattering effect in the foil, the local orbit bump by the bump magnets and dispersive orbit bump by modifying the RF pattern, the multi-particle simulations by ORBIT and TURTLE codes, and some technical features for the extraction magnets are presented.

  6. (Liquid + liquid) equilibria for mixtures of (ethylene glycol + benzene + cyclohexane) at temperatures (298.15, 308.15, and 318.15) K

    Energy Technology Data Exchange (ETDEWEB)

    Mohammad Reza Seyedein Ghannad, S. [School of Chemical, Gas and Petroleum Engineering, Semnan University, Semnan 35195-363 (Iran, Islamic Republic of); Lotfollahi, Mohammad Nader, E-mail: mnlotfollahi@semnan.ac.i [School of Chemical, Gas and Petroleum Engineering, Semnan University, Semnan 35195-363 (Iran, Islamic Republic of); Asl, Ali Haghighi [School of Chemical, Gas and Petroleum Engineering, Semnan University, Semnan 35195-363 (Iran, Islamic Republic of)

    2011-03-15

    Experimental (liquid + liquid) equilibrium (LLE) data for a ternary system containing (ethylene glycol + benzene + cyclohexane) were determined at temperatures (298.15, 308.15, and 318.15) K and at atmospheric pressure. The experimental distribution coefficients and selectivity factors are presented to evaluate the efficiency of the solvent for extraction of benzene from cyclohexane. The effect of temperature in extraction of benzene from the (benzene + cyclohexane) mixture indicated that at lower temperatures the selectivity (S) is higher, but the distribution coefficient (K) is rather lower. The LLE results for the system studied were used to obtain binary interaction parameters in the UNIQUAC and NRTL models by minimizing the root mean square deviations (RMSD) between the experimental results and calculated results. Using the interaction parameters obtained, the phase equilibria in the systems were calculated and plotted. The NRTL model fits the (liquid + liquid) equilibrium data of the mixture studied slightly better. The root mean square deviations (RMSDs) obtained comparing calculated and experimental two-phase compositions are 0.92% for the NRTL model and 0.95% for the UNIQUAC model.

  7. One-step displacement dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of methylmercury in environmental samples.

    Science.gov (United States)

    Liang, Pei; Kang, Caiyan; Mo, Yajun

    2016-01-01

    A novel method for the selective determination of methylmercury (MeHg) was developed by one-step displacement dispersive liquid-liquid microextraction (D-DLLME) coupled with graphite furnace atomic absorption spectrometry. In the proposed method, Cu(II) reacted with diethyldithiocarbamate (DDTC) to form Cu-DDTC complex, which was used as the chelating agent instead of DDTC for the dispersive liquid-liquid microextraction (DLLME) of MeHg. Because the stability of MeHg-DDTC is higher than that of Cu-DDTC, MeHg can displace Cu from the Cu-DDTC complex and be preconcentrated in a single DLLME procedure. MeHg could be extracted into the extraction solvent phase at pH 6 while Hg(II) remained in the sample solution. Potential interference from co-existing metal ions with lower DDTC complex stability was largely eliminated without the need of any masking reagent. Under the optimal conditions, the limit of detection of this method was 13.6ngL(-1) (as Hg), and an enhancement factor of 81 was achieved with a sample volume of 5.0mL. The proposed method was successfully applied for the determination of trace MeHg in some environmental samples with satisfactory results. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Development of a Dispersive Liquid-Liquid Microextraction Method Combined with UV-Visible Spectrophotometry for Determination of Trace Aluminum(III) in Water, Wastewater, Food, Biological, and Pharmaceutical Samples.

    Science.gov (United States)

    Birgani, Nasrin Taghipour; Elhami, Shahla

    2017-01-01

    A simple and sensitive method was proposed for the preconcentration of trace levels of Al(III) prior to its determination by spectrophotometry, based on dispersive liquid-liquid microextraction. The complexation of the Al(III) was performed by chelation with Eriochrome Cyanine R (ECR). In this method, cetyltrimethyl ammonium bromide (CTAB) as a dispersant was dissolved in chloroform as an extractant solvent, and then the solution was rapidly injected by a syringe into the samples containing Al(III), which had already been complexed by ECR at optimized pH. Various parameters were studied and optimized for a 10 mL sample volume. Under the optimum conditions, the LOD (3 times the SD of 10 replicate readings of the reagent blank) and the dynamic range of the calibration obtained were 0.2 ng mL-1 (7 nM) and 1.0-80.0 ng mL-1, respectively. The RSDs for eight replicate determinations of 10 and 60 ng mL-1 of Al(III) were 3.3 and 1.8%, respectively. This strategy was successfully applied to determine the Al concentration in water, wastewater, yogurt, apple, carrot, celery, bread, potato, urine, and Al-Mg syrup samples.

  9. Dispersive liquid-liquid microextraction followed by microwave-assisted silylation and gas chromatography-mass spectrometry analysis for simultaneous trace quantification of bisphenol A and 13 ultraviolet filters in wastewaters.

    Science.gov (United States)

    Cunha, S C; Pena, A; Fernandes, J O

    2015-10-02

    A novel multi-residue gas chromatography-mass spectrometry (GC-MS) method was validated for the simultaneous determination of trace levels (ng/L) of 13 UV-filters and bisphenol A (BPA) in wastewater samples. It was based on dispersive liquid-liquid microextraction (DLMME) followed by rapid microwave-assisted silylation of the analytes. Several parameters of both extraction and derivatization steps such as type of extractive and dispersive solvents, solvent volumes, pH, salt addition, time and power of microwave were evaluated to achieve the highest yield and to attain the lowest detection limits. Optimized DLLME consisted in the formation of a cloudy solution promoted by the fast addition to the sample (10mL) of a mixture of tetrachloroethylene (50μL, extraction solvent) in acetone (1mL, dispersive solvent). The sedimented phase obtained was evaporated and further silylated under the irradiation of 600W microwave for 5min, being the derivatization yields similar to those obtained after a conventional heating process for 30min at 75°C. Limits of detection and quantification of the method using real samples were 2ng/L and 10ng/L, respectively. Mean extraction efficiency of 82% for three concentrations were achieved, supporting the accuracy of the method. Intra-day and inter-day repeatability of measurements (expressed as relative standard deviation) were lower than 22%. The method was successfully applied to the determination of UV-filters and BPA in samples collected from 15 wastewater treatment plants (WWTPs) in Portugal. Eight analytes were detected, among which 2-hydroxy-4-methoxybenzophenone, 2-ethylhexyl-4-(dimethylamino)benzoate, octocrylene, and BPA were consistently found in the three seasons of collection. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Search for a liquid-liquid critical point in models of silica

    OpenAIRE

    Lascaris, Erik; Hemmati, Mahin; Buldyrev, Sergey V.; Stanley, H. Eugene; Angell, C. Austen

    2014-01-01

    Previous research has indicated the possible existence of a liquid-liquid critical point (LLCP) in models of silica at high pressure. To clarify this interesting question we run extended molecular dynamics simulations of two different silica models (WAC and BKS) and perform a detailed analysis of the liquid at temperatures much lower than those previously simulated. We find no LLCP in either model within the accessible temperature range, although it is closely approached in the case of the WA...

  11. Innovative polyelectrolytes/poly(ionic liquid)s for energy and environment

    OpenAIRE

    Ajjan, Fátima N.; Ambrogi, Martina; Tiruye, Girum Ayalneh; Cordella, Daniela; Fernandes, Ana M.; Grygiel, Konrad; Isik, Mehmet; Patil, Nagaraj; Porcarelli, Luca; Rocasalbas, Gillem; Bendramientto, Giordano; Zeglio, Erica; Antonietti, Markus; Detrembleur, Christophe; Inganäs, Olle

    2017-01-01

    This manuscript presents the work carried out within the European Project RENAISSANCE-ITN, which was dedicated to the development of innovative polyelectrolytes for energy and environmental applications. Within the project different types of innovative polyelectrolytes were synthesized such as poly(ionic liquid)s coming from renewable or natural ions, thiazolium cations, cathechol functionalities or from a new generation of cheap deep-eutectic monomers. Further, macromolecular architectures s...

  12. Tuning the stimuli-responsive properties of poly(ionic liquid)s

    OpenAIRE

    Tudor, Alexandru; Florea, Larisa; Diamond, Dermot

    2015-01-01

    Poly(Ionic Liquid)s (PILs) are a class of ionic liquids that feature polymerizable groups in either the cation, the anion or both. PILs can be used in various applications, including solid ion conductors or for CO2 absorption. Several PILs show the presence of a lower critical solution temperature (LCST), making them suitable precursors for the synthesis of stimuli-responsive materials that have the ability to change their conformation in response to variations in their external environment. ...

  13. (Liquid + liquid) equilibria for ternary mixtures of (alkane + benzene + [EMpy] [ESO{sub 4}]) at several temperatures and atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Emilio J.; Calvar, Noelia; Gonzalez, Begona [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain); Dominguez, Angeles [Departamento de Ingenieria Quimica de la Universidad de Vigo, 36310 Vigo (Spain)], E-mail: admguez@uvigo.es

    2009-11-15

    In this work, the separation of benzene from aliphatic hydrocarbons (hexane, or heptane) is investigated by extraction with 1-ethyl-3-methylpyridinium ethylsulphate ionic liquid, [EMpy][ESO{sub 4}]. (Liquid + liquid) equilibria (LLE) data are determined for the ternary systems: {l_brace}hexane (1) + benzene (2) + [EMpy][ESO{sub 4}] (3){r_brace} at T = (283.15, 293.15, 298.15, and 303.15) K and {l_brace}heptane (1) + benzene (2) + [EMpy][ESO{sub 4}] (3){r_brace} at T = (283.15 and 298.15) K and atmospheric pressure. The selectivity and distribution coefficient, derived from the tie line data, were used to determine whether the ionic liquid is a good solvent for the extraction of aromatic from aliphatic compounds. The consistency of the tie line data was ascertained by applying the Othmer-Tobias and Hand equations. The experimental results for the ternary systems were well correlated with the NRTL equation. A study of the temperature effect and the influence of the chain length of the alkanes were realized. The results obtained were compared with other ionic liquids. There are no literature data for the mixtures discussed in this paper.

  14. Seed oil polyphenols: rapid and sensitive extraction method and high resolution-mass spectrometry identification.

    Science.gov (United States)

    Koubaa, Mohamed; Mhemdi, Houcine; Vorobiev, Eugène

    2015-05-01

    Phenolic content is a primary parameter for vegetables oil quality evaluation, and directly involved in the prevention of oxidation and oil preservation. Several methods have been reported in the literature for polyphenols extraction from seed oil but the approaches commonly used remain manually handled. In this work, we propose a rapid and sensitive method for seed oil polyphenols extraction and identification. For this purpose, polyphenols were extracted from Opuntia stricta Haw seed oil, using high frequency agitation, separated, and then identified using a liquid chromatography-high resolution mass spectrometry method. Our results showed good sensitivity and reproducibility of the developed methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Low density solvent-based dispersive liquid-liquid microextraction for the determination of synthetic antioxidants in beverages by high-performance liquid chromatography.

    Science.gov (United States)

    Çabuk, Hasan; Köktürk, Mustafa

    2013-01-01

    A simple and efficient method was established for the determination of synthetic antioxidants in beverages by using dispersive liquid-liquid microextraction combined with high-performance liquid chromatography with ultraviolet detection. Butylated hydroxy toluene, butylated hydroxy anisole, and tert-butylhydroquinone were the antioxidants evaluated. Experimental parameters including extraction solvent, dispersive solvent, pH of sample solution, salt concentration, and extraction time were optimized. Under optimal conditions, the extraction recoveries ranged from 53 to 96%. Good linearity was observed by the square of correlation coefficients ranging from 0.9975 to 0.9997. The relative standard deviations ranged from 1.0 to 5.2% for all of the analytes. Limits of detection ranged from 0.85 to 2.73 ng mL(-1). The method was successfully applied for determination of synthetic antioxidants in undiluted beverage samples with satisfactory recoveries.

  16. Rapid and reliable extraction of genomic DNA from various wild-type and transgenic plants

    Directory of Open Access Journals (Sweden)

    Yang Moon-Sik

    2004-09-01

    Full Text Available Abstract Background DNA extraction methods for PCR-quality DNA from calluses and plants are not time efficient, since they require that the tissues be ground in liquid nitrogen, followed by precipitation of the DNA pellet in ethanol, washing and drying the pellet, etc. The need for a rapid and simple procedure is urgent, especially when hundreds of samples need to be analyzed. Here, we describe a simple and efficient method of isolating high-quality genomic DNA for PCR amplification and enzyme digestion from calluses, various wild-type and transgenic plants. Results We developed new rapid and reliable genomic DNA extraction method. With our developed method, plant genomic DNA extraction could be performed within 30 min. The method was as follows. Plant tissue was homogenized with salt DNA extraction buffer using hand-operated homogenizer and extracted by phenol:chloroform:isoamyl alcohol (25:24:1. After centrifugation, the supernatant was directly used for DNA template for PCR, resulting in successful amplification for RAPD from various sources of plants and specific foreign genes from transgenic plants. After precipitating the supernatant, the DNA was completely digested by restriction enzymes. Conclusion This DNA extraction procedure promises simplicity, speed, and efficiency, both in terms of time and the amount of plant sample required. In addition, this method does not require expensive facilities for plant genomic DNA extraction.

  17. Applications of ionic liquids in biphasic separation: Aqueous biphasic systems and liquid-liquid equilibria.

    Science.gov (United States)

    Shukla, Shashi Kant; Pandey, Shubha; Pandey, Siddharth

    2017-10-10

    Ionic liquids (ILs) have been receiving much attention in many fields of analytical chemistry because of their various interesting properties which distinguish them from volatile organic compounds. They offer both directional and non-directional forces towards a solute molecule and therefore act as excellent solvents for a wide range of polar and non-polar compounds. Because of the presence of various possible interactions, ILs easily undergo biphasic separation with water and other less polar/non-polar organic solvents. Their ability to create biphasic splitting makes them a promising candidate for liquid-liquid separation processes, such as aqueous biphasic systems and liquid-liquid equilibria. Various aspects of ILs in these separation methods are discussed in view of the origin of physical forces responsible for the biphasic interactions, the effect of structural components, temperature, pressure, pH and additives. The specific advantages of using ILs in aqueous biphasic systems and liquid-liquid equilibria in binary and ternary systems are discussed with a view to defining their future role in separation processes by giving major emphasis on developing non-toxic ILs with physical and solution properties tailored to the needs of specific sample preparation techniques. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Liquid-liquid structure transition and nucleation in undercooled Co-B eutectic alloys

    Energy Technology Data Exchange (ETDEWEB)

    He, Yixuan [Northwestern Polytechnical University, State Key Laboratory of Solidification Processing, Xi' an, Shanxi (China); Universite Grenoble Alpes, LNCMI, Grenoble (France); CNRS, LNCMI, Grenoble (France); Li, Jinshan; Wang, Jun; Kou, Hongchao [Northwestern Polytechnical University, State Key Laboratory of Solidification Processing, Xi' an, Shanxi (China); Beagunon, Eric [Universite Grenoble Alpes, LNCMI, Grenoble (France); CNRS, LNCMI, Grenoble (France)

    2017-06-15

    Cyclic superheating and cooling were carried out for the undercooled hypereutectic Co{sub 80}B{sub 20}, eutectic Co{sub 81.5}B{sub 18.5,} and hypoeutectic Co{sub 83}B{sub 17} alloys. For each alloy, there is a critical overheating temperature T{sub c}° at which there is a sharp increase of the mean undercooling, i.e., below (above) T{sub c}°, and the mean undercooling is about 80 °C (200 °C). DSC measurements show that there is a thermal absorption peak in the heating process, the peak temperature of which is nearly equal to the critical overheating temperature, indicating that the temperature-induced liquid-liquid structure transition does occur and should relate highly to nucleation in the undercooled Co-B eutectic melts. The effect of the liquid-liquid structure transition on nucleation was interpreted by the recent nucleation theory that considers the structures of overheated melts, and the composition-dependent overheating temperature was ascribed to the change of local favored structures. The present work provides further evidences for the liquid-liquid structure transition and is helpful for understanding solidification in undercooled melts. (orig.)

  19. Numerical studies on the separation performance of liquid- liquid Hydrocyclone for higher water-cut wells

    Science.gov (United States)

    Osei, H.; Al-Kayiem, H. H.; Hashim, F. M.

    2015-12-01

    Liquid-liquid hydrocyclones have nowadays become very useful in the oil industry because of their numerous applications. They can be installed downhole in the case of a well that produces higher water-oil ratios. The design of a liquid-liquid hydrocyclone for such a task is critical and every geometric part of the hydrocyclone has a part to play as far as separation is concerned. This work, through validated numerical technique, investigated the liquid-liquid hydrocyclone performance for the cases of single-inlet and dual-inlets, with different upper cylindrical lengths, specifically, 30mm and 60mm.It was observed that the hydrocyclones with the 30mm upper cylindrical section perform better than the ones with 60 mm upper cylindrical section. It was again noted that, even though higher number of tangential inlets increases the swirl intensity, they have the tendency to break up the oil droplets within the hydrocyclone because of increasing shear and jet flow interaction.

  20. Managing the social impacts of the rapidly-expanding extractive industries in Greenland

    NARCIS (Netherlands)

    Hansen, Anne Merrild; Vanclay, Frank; Croal, Peter; Skjervedal, Anna Sofie Hurup

    2016-01-01

    The recent rapid expansion of extractive industries in Greenland is both causing high hopes for the future and anxieties among the local population. In the Arctic context, even small projects carry risks of major social impacts at local and national scales, and have the potential to severely affect

  1. Managing the social impacts of the rapidly expanding extractive industries in Greenland

    DEFF Research Database (Denmark)

    Hansen, Anne Merrild; Vanclay, Frank; Croal, Peter

    2016-01-01

    The recent rapid expansion of extractive industries in Greenland is both causing high hopes for the future and anxieties among the local population. In the Arctic context, even small projects carry risks of major social impacts at local and national scales, and have the potential to severely affect...

  2. Low-density solvent-based dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of warfarin in human plasma.

    Science.gov (United States)

    Ghambari, Hoda; Hadjmohammadi, Mohammadreza

    2012-06-15

    Extraction and determination of warfarin, a widely used anticoagulant drug, in human plasma were performed using a new generation of dispersive liquid-liquid microextraction (DLLME) and high performance liquid chromatography (HPLC). The extraction procedure is based on extraction solvents lighter than water and performing of extraction in a specially designed extraction cell. Some important parameters, including kind and volume of extraction and disperser solvents, pH of the sample solution, salt concentration in the sample solution and extraction time were investigated and optimized. Under the optimized conditions (150 μL 1-octanol as extraction solvent, 150 μL methanol as disperser solvent, pH(sample)=2.3, extraction time of 2 min, without salt addition), limit of detection (LOD) of 5 ng mL⁻¹ and extraction recovery of 91.0% were obtained. The calibration curve was linear within the range of 15-3000 ng mL⁻¹ with the square of correlation coefficient (R²) of 0.998. Repeatability and reproducibility of method based on five replicate extraction and determination were 2.8% and 6.5%, respectively. The proposed method was applied successfully for the determination of warfarin in plasma sample from a patient under treatment with this drug, and was demonstrated to be sensitive, efficient, and convenient. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Microwave assisted extraction-solid phase extraction for high-efficient and rapid analysis of monosaccharides in plants.

    Science.gov (United States)

    Zhang, Ying; Li, Hai-Fang; Ma, Yuan; Jin, Yan; Kong, Guanghui; Lin, Jin-Ming

    2014-11-01

    Monosaccharides are the fundamental composition units of saccharides which are a common source of energy for metabolism. An effective and simple method consisting of microwave assisted extraction (MAE), solid phase extraction (SPE) and high performance liquid chromatography-refractive index detector (HPLC-RID) was developed for rapid detection of monosaccharides in plants. The MAE was applied to break down the structure of the plant cells and release the monosaccharides, while the SPE procedure was adopted to purify the extract before analysis. Finally, the HPLC-RID was employed to separate and analyze the monosaccharides with amino column. As a result, the extraction time was reduced to 17 min, which was nearly 85 times faster than soxhlet extraction. The recoveries of arabinose, xylose, fructose and glucose were 85.01%, 87.79%, 103.17%, and 101.24%, with excellent relative standard deviations (RSDs) of 1.94%, 1.13%, 0.60% and 1.67%, respectively. The proposed method was demonstrated to be efficient and time-saving, and had been applied to analyze monosaccharides in tobacco and tea successfully. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Rapid and effective DNA extraction method with bead grinding for a large amount of fungal DNA.

    Science.gov (United States)

    Watanabe, M; Lee, K; Goto, K; Kumagai, S; Sugita-Konishi, Y; Hara-Kudo, Y

    2010-06-01

    To identify a rapid method for extracting a large amount of DNA from fungi associated with food hygiene, extraction methods were compared using fungal pellets formed rapidly in liquid media. Combinations of physical and chemical methods or commercial kits were evaluated with 3 species of yeast, 10 species of ascomycetous molds, and 4 species of zygomycetous molds. Bead grinding was the physical method, followed by chemical methods involving sodium dodecyl sulfate (SDS), cetyl trimethyl ammonium bromide (CTAB), and benzyl chloride and two commercial kits. Quantity was calculated by UV absorbance at 260 nm, quality was determined by the ratio of UV absorbance at 260 and 280 nm, and gene amplifications and electrophoresis profiles of whole genomes were analyzed. Bead grinding with the SDS method was the most effective for DNA extraction for yeasts and ascomycetous molds, and bead grinding with the CTAB method was most effective with zygomycetous molds. For both groups of molds, bead grinding with the CTAB method was the best approach for DNA extraction. Because this combination also is relatively effective for yeasts, it can be used to extract a large amount of DNA from a wide range of fungi. The DNA extraction methods are useful for developing gene indexes to identify fungi with molecular techniques, such as DNA fingerprinting.

  5. RAPID AND EFFICIENT METHOD FOR ENVIRONMENTAL DNA EXTRACTION AND PURIFICATION FROM SOIL

    Directory of Open Access Journals (Sweden)

    J. Hamedi

    2016-06-01

    Full Text Available Large proportion of microbial population in the world is unculturable. Extraction of total DNA from soil is usually a crucial step considering to the difficulties of study the uncultivable microorganisms. Humic acid is considered as the main inhibitory agent in the environmental DNA studies. Here, we introduced a rapid and efficient method for DNA extraction and purification from soil. Yield of DNA extraction by the presented method was 130 ng/µl. Three conventional methods of DNA extraction including liquid nitrogen incursion, bead beating and sonication were performed as control methods. Yield of DNA extraction by these methods were 110, 90 and 50 ng/µl, respectively. A rapid and efficient one step DNA purification method was introduced instead of hazardous conventional phenol-chloroform methods. Humic acid removal percentage by the introduced method was 95.8 % that is comparable with 97 % gained by the conventional gel extraction method and yield of DNA after purification was 84 % and 73 %, respectively. This study could be useful in molecular ecology and metagenomics study as a fast and reliable method.

  6. A new treatment by dispersive liquid-liquid microextraction for the determination of parabens in human serum samples.

    Science.gov (United States)

    Vela-Soria, F; Ballesteros, O; Rodríguez, I; Zafra-Gómez, A; Ballesteros, L; Cela, R; Navalón, A

    2013-09-01

    Alkyl esters of p-hydroxybenzoic acid (parabens) are a family of compounds that have been in use since the 1920s as preservatives in cosmetic formulations, with one of the lowest rates of skin problems reported in dermatological patients. However, in the last few years, many scientific publications have demonstrated that parabens are weak endocrine disruptors, meaning that they can interfere with the function of endogenous hormones, increasing the risk of breast cancer. In the present work, a new sample treatment method is introduced based on dispersive liquid-liquid microextraction for the extraction of the most commonly used parabens (methyl-, ethyl-, propyl-, and butylparaben) from human serum samples followed by separation and quantification using ultrahigh performance liquid chromatography-tandem mass spectrometry. The method involves an enzymatic treatment to quantify the total content of parabens. The extraction parameters (solvent and disperser solvent, extractant and dispersant volume, pH of the sample, salt addition, and extraction time) were accurately optimized using multivariate optimization strategies. Ethylparaben ring (13)C6-labeled was used as surrogate. Limits of quantification ranging from 0.2 to 0.7 ng mL(-1) and an interday variability (evaluated as relative standard deviations) from 3.8 to 11.9 % were obtained. The method was validated using matrix-matched calibration standard and a spike recovery assay. Recovery rates for spiked samples ranged from 96 to 106 %, and a good linearity up to concentrations of 100 ng mL(-1) was obtained. The method was satisfactorily applied for the determination of target compounds in human serum samples.

  7. Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography.

    Science.gov (United States)

    Fernández, P; Regenjo, M; Bermejo, A M; Fernández, A M; Lorenzo, R A; Carro, A M

    2015-04-01

    Opioids and cocaine are widely used at present, both for recreational purposes and as drugs of abuse. This raises the need to develop new analytical methods specifically designed for the simultaneous detection of several drugs of abuse in biological samples. In this work, dispersive liquid-liquid microextraction (DLLME) was assessed as a new sample treatment for the simultaneous extraction of morphine (MOR), 6-acetylmorphine (6AM), cocaine (COC), benzoylecgonine (BZE) and methadone (MET) from human plasma. Preliminary assays were done before developing an experimental design based on a Uniform Network Doehlert which allowed the optimum extraction conditions to be identified, namely: a volume of extractant solvent (chloroform) and dispersant solvent (acetonitrile) of 220 µl and 3.2 ml, respectively; 0.2 g of NaCl as a salting-out additive; pH 10.6 and ultrasound stirring for 3.5 min. The resulting extracts were analyzed by high-performance liquid chromatography with photodiode array detection (HPLC-PDA), using an XBridge® RP18 column (250 × 4.6 mm i.d., 5 µm particle size). Calibration graphs were linear over the concentration range 0.1-10 µg ml⁻¹, and detection limits ranged from 13.9 to 28.5 ng ml⁻¹. Precision calculated at three different concentration levels in plasma was included in the range 0.1-6.8% RSD. Recoveries of the five drugs were all higher than 84% on average. Finally the proposed method was successfully applied to 22 plasma samples from heroin, cocaine and/or methadone users, and the most frequently detected drug was benzoylecgonine, followed by methadone, cocaine and morphine. Copyright © 2014 John Wiley & Sons, Ltd.

  8. Solid-state chemiluminescence assay for ultrasensitive detection of antimony using on-vial immobilization of CdSe quantum dots combined with liquid-liquid-liquid microextraction.

    Science.gov (United States)

    Costas-Mora, Isabel; Romero, Vanesa; Lavilla, Isela; Bendicho, Carlos

    2013-07-25

    On-vial immobilized CdSe quantum dots (QDs) are applied for the first time as chemiluminescent probes for the detection of trace metal ions. Among 17 metal ions tested, inhibition of the chemiluminescence when CdSe QDs are oxidized by H2O2 was observed for Sb, Se and Cu. Liquid-liquid-liquid microextraction was implemented in order to improve the selectivity and sensitivity of the chemiluminescent assay. Factors influencing both the CdSe QDs/H2O2 chemiluminescent system and microextraction process were optimized for ultrasensitive detection of Sb(III) and total Sb. In order to investigate the mechanism by which Sb ions inhibit the chemiluminescence of the CdSe QDs/H2O2 system, atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), UV-vis absorption and fluorescence measurements were performed. The selection of the appropriate CdSe QDs capping ligand was found to be a critical issue. Immobilization of QDs caused the chemiluminescence signal to be enhanced by a factor of 100 as compared to experiments carried out with QDs dispersed in the bulk aqueous phase. Under optimized conditions, the detection limit was 6 ng L(-1) Sb and the repeatability expressed as relative standard deviation (N=7) was about 1.3%. An enrichment factor of 95 was achieved within only 3 min of microextraction. Several water samples including drinking, spring, and river waters were analyzed. The proposed method was validated against CRM NWTM-27.2 fortified lake water, and a recovery study was performed with different types of water samples. Sb recoveries ranged from 94 to 105%. A fast, miniaturized and relatively inexpensive assay for selective and sensitive detection of Sb(III) and total Sb in waters is accomplished. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Low-density magnetofluid dispersive liquid-liquid microextraction for the fast determination of organochlorine pesticides in water samples by GC-ECD.

    Science.gov (United States)

    Shen, Zhigang; He, Zeying; Wang, Peng; Zhou, Zhiqiang; Sun, Mingjing; Li, Jingdong; Liu, Donghui

    2013-09-02

    A new micro-extraction technique named low-density magnetofluid dispersive liquid-liquid microextraction (LMF-DMMLE) has been developed, which permits a wider range of solvents and can be combined with various detection methods. Comparing with the existing low density solvents micro-extraction methods, no special devices and complicated operations were required during the whole extraction process. Dispersion of the low-density magnetofluid into the aqueous sample is achieved by using vortex mixing, so disperser solvent was unnecessary. The extraction solvent was collected conveniently with an external magnetic field placed outside the extraction container after dispersing. Then, the magnetic nanoparticles were easily removed by adding precipitation reagent under the magnetic field. In order to evaluate the validity of this method, ten organochlorine pesticides (OCPs) were chosen as the analytes. Parameters influencing the extraction efficiency such as extraction solvents, volume of extraction solvents, extraction time, and ionic strength were investigated and optimized. Under the optimized conditions, this method showed high extraction efficiency with low limits of detection of 1.8-8.4 ng L(-1), good linearity in the range of 0.05-10.00 μg L(-1) and the precisions were in the range of 1.3-9.6% (RSD, n=5). Finally, this method was successfully applied in the determination of OCPs in real water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction for the simultaneous determination of 12 new antidepressants and 2 antipsychotics in whole blood by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Xiujuan; Zheng, Shuiqing; Le, Jian; Qian, Zheyuan; Zhang, Runsheng; Hong, Zhanying; Chai, Yifeng

    2017-08-05

    Antidepressant drugs are widely used in the treatment of different psychiatric disorders, as well as in conjunction with antipsychotics for the treatment of major depressive disorder. In this study, a simple and rapid ultrasound-assisted low-density solvent dispersive liquid-liquid microextraction (UA-LDS-DLLME) method was developed for the simultaneous determination of 12 new antidepressants (norfluoxetine, fluoxetine, fluvoxamine, agomelatine, mirtazapine, moclobemide, melitracen, N-desmethylmirtazapine, maprotiline, sertraline, citalopram, paroxetine) and 2 antipsychotics (clozapine and haloperidol) in human whole blood by gas chromatography-mass spectrometry (GC-MS). Different parameters affecting the UA-LDS-DLLME were optimized and the optimal conditions were as follows: 100μL of toluene as extraction solvent, extraction pH 12 and 3min of ultrasound stirring. Good linearity (R2≥0.991) was obtained at the concentration range of 15-1500ng/mL for norfluoxetine, fluoxetine, fluvoxamine, melitracen, maprotiline and citalopram, and 5-500ng/mL for agomelatine, mirtazapine, moclobemide, N-desmethylmirtazapine, sertraline, paroxetine, clozapine and haloperidol. The intra-day and inter-day precision were all less than 10%, and accuracy of intra-day and inter-day were in the range of -12.7% to 7.9% and -13.9 to 11.8%, respectively. The extraction recoveries of most analytes were more than 60%. The UA-LDS-DLLME/GC-MS method was demonstrated with acceptable precision, accuracy and good specificity for the simultaneous determination of 12 antidepressants and 2 antipsychotics, and has been successfully applied in a real case. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. In-situ ionic liquid dispersive liquid-liquid microextraction using a new anion-exchange reagent combined Fe3O4 magnetic nanoparticles for determination of pyrethroid pesticides in water samples.

    Science.gov (United States)

    Fan, Chen; Liang, You; Dong, Hongqiang; Ding, Guanglong; Zhang, Wenbing; Tang, Gang; Yang, Jiale; Kong, Dandan; Wang, Deng; Cao, Yongsong

    2017-07-04

    In this work, in-situ ionic liquid dispersive liquid-liquid microextraction combined ultrasmall Fe3O4 magnetic nanoparticles was developed as a kind of pretreatment method to detect pyrethroid pesticides in water samples. New anion-exchange reagents including Na[DDTC] and Na[N(CN)2] were optimized for in-situ extraction pyrethroids, which showed enhanced microextraction performance. Pyrethroids were enriched by hydrophilic ionic liquid [P4448][Br] (aqueous solution, 200 μL, 0.2 mmol mL-1) reaction in-situ with anion-exchange reagent Na[N(CN)2] (aqueous solution, 300 μL, 0.2 mmol mL-1) forming hydrophobic ionic liquid as extraction agent in water sample (10 mL). Ultrasmall superparamagnetic iron oxide nanoparticles (30 mg) were used to collect the mixture of ionic liquid and pyrethroids followed by elution with acetonitrile. The extraction of ionic liquid strategies was unique and efficiently fulfilled with high enrichment factors (176-213) and good recoveries (80.20-117.31%). The method was successively applied to the determination of pyrethroid pesticides in different kinds of water samples with the limits of detection ranged from 0.16 to 0.21 μg L-1. The proposed method is actually nanometer-level microextraction (average size 80 nm) with the advantages of simplicity, rapidity, and sensitivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid, room-temperature synthesis of amorphous selenium/protein composites using Capsicum annuum L extract

    Science.gov (United States)

    Li, Shikuo; Shen, Yuhua; Xie, Anjian; Yu, Xuerong; Zhang, Xiuzhen; Yang, Liangbao; Li, Chuanhao

    2007-10-01

    We describe the formation of amorphous selenium (α-Se)/protein composites using Capsicum annuum L extract to reduce selenium ions (SeO32-) at room temperature. The reaction occurs rapidly and the process is simple and easy to handle. A protein with a molecular weight of 30 kDa extracted from Capsicum annuum L not only reduces the SeO32- ions to Se0, but also controls the nucleation and growth of Se0, and even participates in the formation of α-Se/protein composites. The size and shell thickness of the α-Se/protein composites increases with high Capsicum annuum L extract concentration, and decreases with low reaction solution pH. The results suggest that this eco-friendly, biogenic synthesis strategy could be widely used for preparing inorganic/organic biocomposites. In addition, we also discuss the possible mechanism of the reduction of SeO32- ions by Capsicum annuum L extract.

  13. Changing Hydrogen-Bond Structure during an Aqueous Liquid-Liquid Transition Investigated with Time-Resolved and Two-Dimensional Vibrational Spectroscopy.

    Science.gov (United States)

    Bruijn, Jeroen R; van der Loop, Tibert H; Woutersen, Sander

    2016-03-03

    We investigate the putative liquid-liquid phase transition in aqueous glycerol solution, using the OD-stretch mode in dilute OD/OH isotopic mixtures to probe the hydrogen-bond structure. The conversion exhibits Avrami kinetics with an exponent of n = 2.9 ± 0.1 (as opposed to n = 1.7 observed upon inducing ice nucleation and growth in the same sample), which indicates a transition from one liquid phase to another. Two-dimensional infrared (2D-IR) spectroscopy shows that the initial and final phases have different hydrogen-bond structures: the former has a single Gaussian distribution of hydrogen-bond lengths, whereas the latter has a bimodal distribution consisting of a broad distribution and a narrower, ice-like distribution. The 2D-IR spectrum of the final phase is identical to that of ice/glycerol at the same temperature. Combined with the kinetic data this suggests that the liquid-liquid transformation is immediately followed by a rapid formation of small (probably nanometer-sized) ice crystals.

  14. Determination of four sulfonylurea herbicides in tea by matrix solid-phase dispersion cleanup followed by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Liang, Pei; Wang, Jinjin; Liu, Guojiao; Guan, Jinyan

    2014-09-01

    Matrix solid-phase dispersion combined with dispersive liquid-liquid microextraction has been developed as a new sample pretreatment method for the determination of four sulfonylurea herbicides (chlorsulfuron, bensulfuron-methyl, chlorimuron-ethyl, and pyrazosulfuron) in tea by high-performance liquid chromatography with diode array detection. The extraction and cleanup by matrix solid-phase dispersion was carried out by using CN-silica as dispersant and carbon nanotubes as cleanup sorbent eluted with acidified dichloromethane. The eluent of matrix solid-phase dispersion was evaporated and redissolved in 0.5 mL methanol, and used as the dispersive solvent of the following dispersive liquid-liquid microextraction procedure for further purification and enrichment of the target analytes before high-performance liquid chromatography analysis. Under the optimum conditions, the method yielded a linear calibration curve in the concentration range from 5.0 to 10 000 ng/g for target analytes with a correlation coefficients (r(2)) ranging from 0.9959 to 0.9998. The limits of detection for the analytes were in the range of 1.31-2.81 ng/g. Recoveries of the four sulfonylurea herbicides at two fortification levels were between 72.8 and 110.6% with relative standard deviations lower than 6.95%. The method was successfully applied to the analysis of four sulfonylurea herbicides in several tea samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Fully-automated in-syringe dispersive liquid-liquid microextraction for the determination of caffeine in coffee beverages.

    Science.gov (United States)

    Frizzarin, Rejane M; Maya, Fernando; Estela, José M; Cerdà, Víctor

    2016-12-01

    A novel fully-automated magnetic stirring-assisted lab-in-syringe analytical procedure has been developed for the fast and efficient dispersive liquid-liquid microextraction (DLLME) of caffeine in coffee beverages. The procedure is based on the microextraction of caffeine with a minute amount of dichloromethane, isolating caffeine from the sample matrix with no further sample pretreatment. Selection of the relevant extraction parameters such as the dispersive solvent, proportion of aqueous/organic phase, pH and flow rates have been carefully evaluated. Caffeine quantification was linear from 2 to 75mgL(-1), with detection and quantification limits of 0.46mgL(-1) and 1.54mgL(-1), respectively. A coefficient of variation (n=8; 5mgL(-1)) of a 2.1% and a sampling rate of 16h(-1), were obtained. The procedure was satisfactorily applied to the determination of caffeine in brewed, instant and decaf coffee samples, being the results for the sample analysis validated using high-performance liquid chromatography. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Application of response surface method for optimization of dispersive liquid-liquid microextraction of water-soluble components of Rosa damascena Mill. essential oil.

    Science.gov (United States)

    Sereshti, Hassan; Karimi, Maryam; Samadi, Soheila

    2009-01-09

    Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was applied for the determination of Rose water constituents. The effective parameters such as volume of extraction and disperser solvents, temperature, and salt effect were inspected by a full factorial design to identify important parameters and their interactions. It showed that salt addition had no effect on the efficiency. Next, a central composite design was applied to obtain optimum point of the important parameters. The optimal condition was obtained as 37.0 microL for extractor, 0.42 mL for disperser and temperature for 48 degrees C. The main components that were extracted at the optimum point were benzeneethanol (24.87%), geraniol (23.07%), beta-citronellol (22.38%), nerol (8.48%), eugenol (5.98%) and linalool (5.62%).

  17. Rapid DNA extraction protocol from stool, suitable for molecular genetic diagnosis of colon cancer.

    Science.gov (United States)

    Abbaszadegan, Mohammad Reza; Velayati, Arash; Tavasoli, Alireza; Dadkhah, Ezzat

    2007-07-01

    Colorectal cancer (CRC) is one of the most common forms of cancers in the world and is curable if diagnosed at the early stage. Analysis of DNA extracted from stool specimens is a recent advantage to cancer diagnostics. Many protocols have been recommended for DNA extraction from stool, and almost all of them are difficult and time consuming, dealing with high amount of toxic materials like phenol. Their results vary due to sample collection method and further purification treatment. In this study, an easy and rapid method was optimized for isolating the human DNA with reduced PCR inhibitors present in stool. Fecal samples were collected from 10 colonoscopy-negative adult volunteers and 10 patients with CRC. Stool (1 g) was extracted using phenol/chloroform based protocol. The amplification of P53 exon 9 was examined to evaluate the extraction efficiency for human genomic targets and also compared its efficiency with Machiels et al. and Ito et al. protocols. The amplification of exon 9 of P53 from isolated fecal DNA was possible in most cases in 35 rounds of PCR using no additional purification procedure for elimination of the remaining inhibitors.inhibitors. A useful, rapid and easy protocol for routine extraction of DNA from stool was introduced and compared with two previous protocols.

  18. The rapid determination of sideroxylonals in Eucalyptus foliage by extraction with sonication followed by HPLC.

    Science.gov (United States)

    Wallis, Ian R; Foley, William J

    2005-01-01

    A rapid method is described for the quantification of sideroxylonals, a group of formylated phloroglucinol compounds found in some eucalypts. Samples of dry, ground foliage were extracted by sonication with 20% methanol in acetonitrile, 7% water in acetonitrile or 40% water in acetonitrile and the extracts analysed by reversed phase HPLC. The extracts from the two water-acetonitrile extractions were stable for at least 48 h. All three sonication methods recovered more sideroxylonals than did the Soxhlet extraction with petroleum spirit and acetone. Adding 0.1% trifluoracetic acid to the water-acetonitrile extraction solvents led to even higher recoveries of sideroxylonals. Soaking the sample in extracting solvent for 5 min recovered 70% of the sideroxylonals, whilst sonicating the suspension for 1 min recovered the remainder. The developed method involving sonication of the sample for 5 min in 7% water in acetonitrile with 0.1% trifluoroacetic acid is fast and requires minimal equipment and solvents compared with the traditional methods. With an autosampler it is possible to prepare and run 100 samples a day. More importantly, the technique is ideal for the analysis of small samples, e.g. individual leaves, which is essential when studying the evolutionary ecology of eucalypts.

  19. Selective dispersive liquid-liquid microextraction and preconcentration of Ni(II) into a micro droplet followed by ETAAS determination using a yellow Schiff's base bisazanyl derivative

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Kamal, E-mail: Alizadehk@yahoo.com [Department of Chemistry, Lorestan University, Khorramabad (Iran, Islamic Republic of); Nemati, Hadi; Zohrevand, Somaieh; Hashemi, Payman; Kakanejadifard, Ali [Department of Chemistry, Lorestan University, Khorramabad (Iran, Islamic Republic of); Shamsipur, Mojtaba [Department of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of); Ganjali, Mohammad Reza [Center of Excellence in Electrochemistry, University of Tehran, Tehran (Iran, Islamic Republic of); Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of); Faridbod, Farnoush [Endocrinology and Metabolism Research Center, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2013-03-01

    A simple, rapid and sensitive method was developed for the selective separation and preconcentration of Ni(II) using dispersive liquid-liquid microextraction, by a yellow Schiff's base bisazanyl derivative, as a selective complexing agent. In this method, a mixture of 45 {mu}L chloroform (extraction solvent) and 450 {mu}L tetrahydrofuran (dispersive solvent) is rapidly injected by syringe into a 5 mL aqueous sample containing 3% (w/v) sodium chloride and an appropriate amount of the Schiff's base. As a result, a cloudy solution is formed by entire dispersion of the extraction solvent into the aqueous phase. After centrifuging for 5 min at 5000 rpm, the sedimented phase is directly injected into the electrothermal atomic absorption spectrometry for Ni(II) determination. Some important parameters, such as kind and volume of extraction and dispersive solvents, extraction time, salt effect, pH and concentration of the chelating agent have been optimized. Under the optimum conditions, the enrichment factor for the presented method is 138. The calibration curve was linear over a nickel concentration range of 10-50 ng mL{sup -1}. The detection limit and relative standard deviation were 0.04 ng mL{sup -1} and 2.1%, respectively. The method was successfully applied to the extraction and determination of Ni(II) in different water samples. - Highlights: Black-Right-Pointing-Pointer A new synthesized schiff's base was used for selective separation of Ni(II) ions. Black-Right-Pointing-Pointer The method based on DLLME was successfully applied to the determination of Ni(II). Black-Right-Pointing-Pointer A cloudy solution is formed by entire dispersion of the extraction solvent into the aqueous phase. Black-Right-Pointing-Pointer In this work, the response surface analysis was used for the optimization purpose. Black-Right-Pointing-Pointer The curvature of response surface reflects the interactive effect of the variables.

  20. Production of Self-Assembled Fullerene (C60) Nanocrystals at Liquid-Liquid Interface.

    Science.gov (United States)

    Shrestha, Rekha Goswami; Shrestha, Lok Kumar; Abe, Masahiko; Ariga, Katsuhiko

    2015-03-01

    Here we present self-assembled nanostructure of functional molecule fullerene (C60) at liquid-liquid interface. The nanostructured nanocrystals were grown at liquid-liquid interface of isopropyl alcohol (IPA) and C60 solution in butylbenzene under ambient condition of temperature and pressure, and characterized by Raman scattering, power X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The crystal formation mechanism is driven by supersaturation related to the low solubility of C60 in IPA. A slow diffusion of IPA towards the C60 solution causes unsaturation of C60 at the liquid-liquid interface and consequently small clusters of C60 is formed at the interface, which acts as the nucleation site. Further diffusion of IPA supplies the C60 molecules from bulk to the interface promoting the crystal growth. Based on SEM and TEM observation, the average size of the individual hexagonal bipyramid nanocrystal is found to be ca. 1.4 µm and the average size of their assembly is found to be approximately 2 µm. XRD measurements have shown that these materials are crystalline with mixed face-centered cubic (cell dimension: a = 1.352 nm, and V = 2.475 nm3) and hexagonal (cell dimension: a = 1.452 nm, c = 1.207 nm, c/a = 0.831, and V = 2.475 nm3) structures. Raman scattering measurements showed two Ag and six Hg vibration bands, which are similar to those obtained in the pristine C60.

  1. Extraction of DNA by magnetic ionic liquids: tunable solvents for rapid and selective DNA analysis.

    Science.gov (United States)

    Clark, Kevin D; Nacham, Omprakash; Yu, Honglian; Li, Tianhao; Yamsek, Melissa M; Ronning, Donald R; Anderson, Jared L

    2015-02-03

    DNA extraction represents a significant bottleneck in nucleic acid analysis. In this study, hydrophobic magnetic ionic liquids (MILs) were synthesized and employed as solvents for the rapid and efficient extraction of DNA from aqueous solution. The DNA-enriched microdroplets were manipulated by application of a magnetic field. The three MILs examined in this study exhibited unique DNA extraction capabilities when applied toward a variety of DNA samples and matrices. High extraction efficiencies were obtained for smaller single-stranded and double-stranded DNA using the benzyltrioctylammonium bromotrichloroferrate(III) ([(C8)3BnN(+)][FeCl3Br(-)]) MIL, while the dicationic 1,12-di(3-hexadecylbenzimidazolium)dodecane bis[(trifluoromethyl)sulfonyl]imide bromotrichloroferrate(III) ([(C16BnIM)2C12(2+)][NTf2(-), FeCl3Br(-)]) MIL produced higher extraction efficiencies for larger DNA molecules. The MIL-based method was also employed for the extraction of DNA from a complex matrix containing albumin, revealing a competitive extraction behavior for the trihexyl(tetradecyl)phosphonium tetrachloroferrate(III) ([P6,6,6,14(+)][FeCl4(-)]) MIL in contrast to the [(C8)3BnN(+)][FeCl3Br(-)] MIL, which resulted in significantly less coextraction of albumin. The MIL-DNA method was employed for the extraction of plasmid DNA from bacterial cell lysate. DNA of sufficient quality and quantity for polymerase chain reaction (PCR) amplification was recovered from the MIL extraction phase, demonstrating the feasibility of MIL-based DNA sample preparation prior to downstream analysis.

  2. Development of a coupled dispersive liquid-liquid micro-extraction ...

    African Journals Online (AJOL)

    subject of the biofuel generation project through the enhanced microbial biodegradation of sewage algae. The river water samples were collected from Liphiring River ... solutions: methanol, acetonitrile, chloroform, ethylacetate, and toluene, as well as their binary mixtures, having noted the importance of solvent mixtures on ...

  3. A new oxalate co-conversion technology based on liquid/liquid extraction columns

    Energy Technology Data Exchange (ETDEWEB)

    Borda, Gilles; Ode, Denis; Duhamet, Jean; Allegri, Patrick [CEA Nuclear Energy Division - Fuel Cycle Technology Division - System and Chemical Engineering Device Marcoule - 30207 Bagnols sur Ceze (France)

    2008-07-01

    The current objective of fabricating non proliferating nuclear fuel by 'direct' coprecipitation of uranium, plutonium and minor actinides requires a new process to replace the (co)precipitation step. The technological impact of an increased capacity on the work zone could require the development of a different concept for a continuous device capable of ensuring the proposed goal. A new type of device designed and patented by the Cea was tested in 2007. The patent is for organic confinement in a pulsed column. First, precipitation of cerium or neodymium alone has been carried out in this device, with satisfactory results. Moreover, a recent test campaign demonstrated that a uranium-cerium co-precipitate easily forms when the two nitrates are mixed in a pulsed column of the same size operating under very similar process conditions. Qualitatively, the co-precipitate meets the process requirements. (authors)

  4. Optimization of regeneration process of waste lubricant oil by liquid-liquid extraction

    OpenAIRE

    Villanti, Giovanni Luigi

    2016-01-01

    Lubricating oils are one of the most important fluids used for the correct operation of almost all engines and machines. They play a fundamental role in order to avoid friction and wear, and transfer of heat generated between metallic surfaces. After its use, the lubricant must be replaced because its degradation and contamination by water, salts, metals, carbonaceous compounds, etc. diminish their properties. The used oil may be a serious environmental problem if not properly ...

  5. Hydrophobic polymer monoliths as novel phase separators: Application in continuous liquid-liquid extraction systems

    NARCIS (Netherlands)

    Peroni, D.; Vanhoutte, D.; Vilaplana, F.; Schoenmakers, P.; de Koning, S.; Janssen, H.-G.

    2012-01-01

    Hydrophobic macroporous polymer monoliths are shown to be interesting materials for the construction of "selective solvent gates". With the appropriate surface chemistry and porous properties the monoliths can be made permeable only for apolar organic solvents and not for water. Different poly(butyl

  6. Liquid-liquid extraction of enzymes by affinity aqueous two-phase systems

    Directory of Open Access Journals (Sweden)

    Xu Yan

    2003-12-01

    Full Text Available From analytical to commercial scale, aqueous two-phase systems have their application in the purification, characterization and study of biomaterials. In order to improve the selectivity of the systems, the biospecific affinity ligands were introduced. In the affinity partitioning aqueous two-phase system, have many enzymes been purified. This review discusses the partitioning of some enzymes in the affinity aqueous two-phase systems in regard to the different ligands, including reactive dyes, metal ions and other ligands. Some integration of aqueous two-phase system with other techniques for more effective purification of enzymes are also presented.Tanto em escala de laboratório como industrial, os sistemas de duas fases aquosas podem ser utilizados para a purificação, caracterização e estudos de biomateriais. Para aumentar a seletividade desse sistema, ligantes de afinidade bioespecíficos podem ser utilizados. No sistema de duas fases aquosas por afinidade, muitas enzimas podem ser purificadas. Neste artigo de revisão, a partição de algumas enzimas por esse tipo de afinidade, utilizando diferentes ligantes como corantes e íons metálicos, são discutidas. Além disso, a integração desse sistema de duas fases aquosas com outras técnicas de purificação estão sendo apresentados, com o objetivo mostrar a melhoria da eficiência do processo.

  7. Liquid-Liquid Extraction in Systems Containing Butanol and Ionic Liquids – A Review

    National Research Council Canada - National Science Library

    Artur Kubiczek; Władysław Kamiński

    2017-01-01

    Room-temperature ionic liquids (RTILs) are a moderately new class of liquid substances that are characterized by a great variety of possible anion-cation combinations giving each of them different properties...

  8. Liquid-liquid equilibria for binary and ternary polymer solutions with PC-SAFT

    DEFF Research Database (Denmark)

    Lindvig, Thomas; Michelsen, Michael Locht; Kontogeorgis, Georgios

    2004-01-01

    are used for investigating the correlative and predictive capabilities of the thermodynamic model PC-SAFT. The investigation shows that the model correlates well experimental LLE data for binary as well as ternary systems but further predicts the behavior of the ternary systems with reasonably good......Two algorithms for evaluating liquid-liquid equilibria (LLE) for binary and ternary polymer solutions are presented. The binary algorithm provides the temperature versus concentration cloud-point curve at fixed pressure, whereas the ternary algorithm provides component 1 versus component 2...

  9. Liquid-liquid equilibria for glycols plus hydrocarbons: Data and correlation

    DEFF Research Database (Denmark)

    Derawi, Samer; Kontogeorgis, Georgios; Stenby, Erling Halfdan

    2002-01-01

    Liquid-liquid equilibrium data for seven binary glycol-hydrocarbon systems have been measured in the temperature range 32 degreesC to 80 degreesC and at the pressure 1 bar. The measured systems are monoethylene glycol (MEG) + heptane, methyleyclohexane (MCH) + hexane, propylene glycol (PG......) + heptane, diethylene glycol (DEG) + heptane, triethylene glycol (TEG) + heptane, and tetraethylene glycol (TETRA) + heptane. The data obtained were correlated with the NRTL model and two different versions of the UNIQUAC equation. The NRTL model and one of the UNIQUAC equations (UQ 4) have a linear...

  10. Liquid - liquid equilibria of the water + butyric acid + decanol ternary system

    Directory of Open Access Journals (Sweden)

    S.I. Kirbaslar

    2006-09-01

    Full Text Available Liquid-liquid equilibrium (LLE data for the water + butyric acid + decanol ternary system were determined experimentally at temperatures of 298.15, 308.15 and 318.15 K. Complete phase diagrams were obtained by determining the solubility curve and the tie lines. The reliability of the experimental tie line data was confirmed with the Othmer-Tobias correlation. The UNIFAC method was used to predict the phase equilibrium of the system using the interaction parameters for groups CH3, CH2, COOH, OH and H2O determined experimentally. Distribution coefficients and separation factors were evaluated for the immiscibility region.

  11. Ternary liquid-liquid equilibria measurement for epoxidized soybean oil + acetic acid + water.

    Science.gov (United States)

    Cai, Shuang-Fei; Wang, Li-Sheng; Yan, Guo-Qing; Li, Yi; Feng, Yun-Xia; Linghu, Rong-Gang

    2012-01-01

    Liquid-liquid equilibria (LLE) data were measured for ternary system epoxidized soybean oil (ESO) + acetic acid + water at 313.15, 323.15 and 333.15 K, respectively. The consistency of the measured LLE data was tested, using Othmer-Tobias correlation and root-mean-square deviation (sigma) in mass fraction of water in the lower phase and average value of the absolute difference (AAD) between experimental mass fraction of epoxidized soybean oil in the upper phase and that calculated using Othmer-Tobias correlation.

  12. CO2 Capture with Liquid-Liquid Phase Change Solvents: A Thermodynamic Study

    DEFF Research Database (Denmark)

    Waseem Arshad, Muhammad; Fosbøl, Philip Loldrup; von Solms, Nicolas

    2017-01-01

    Extended UNIQUAC thermodynamic framework was implemented in this work to model the aqueous blend of N, N-Diethylethanolamine (DEEA) and N-Methyl-1,3-diaminopropane (MAPA) for CO2 capture. The model parameters were estimated first for the two ternary systems, H2O-DEEA-CO2 and H2O-MAPA-CO2, followed...... by the quaternary H2O-DEEAMAPA-CO2 system which gives liquid-liquid phase split when reacted with carbon dioxide. A total of 94 model parameters and 6 thermodynamic properties were fitted to approximately 1500 equilibrium and thermal experimental data consisting of pureamine vapor pressure (Pvap), vapor...

  13. Communication: Protein dynamical transition vs. liquid-liquid phase transition in protein hydration water

    Science.gov (United States)

    Schirò, Giorgio; Fomina, Margarita; Cupane, Antonio

    2013-09-01

    In this work, we compare experimental data on myoglobin hydrated powders from elastic neutron scattering, broadband dielectric spectroscopy, and differential scanning calorimetry. Our aim is to obtain new insights on the connection between the protein dynamical transition, a fundamental phenomenon observed in proteins whose physical origin is highly debated, and the liquid-liquid phase transition (LLPT) possibly occurring in protein hydration water and related to the existence of a low temperature critical point in supercooled water. Our results provide a consistent thermodynamic/dynamic description which gives experimental support to the LLPT hypothesis and further reveals how fundamental properties of water and proteins are tightly related.

  14. Application of the CPA equation of state to glycol/hydrocarbons liquid-liquid equilibria

    DEFF Research Database (Denmark)

    Derawi, Samer; Michelsen, Michael Locht; Kontogeorgis, Georgios

    2003-01-01

    is achieved with solely a single interaction parameter per binary system. The correlation procedure as well as the nature of the experimental data play a crucial role in the parameter estimation and they are thus extensively discussed. (C) 2003 Elsevier Science B.V. All rights reserved....... shown in the past to be a successful model for phase equilibria calculations for systems containing water, hydrocarbons and alcohols. In this work, CPA is applied for the first time to liquid-liquid equilibria (LLE) for systems containing glycols and hydrocarbons. It is shown that excellent correlation...

  15. Electrical control of Faraday rotation at a liquid-liquid interface.

    Science.gov (United States)

    Marinescu, Monica; Kornyshev, Alexei A; Flatté, Michael E

    2015-01-01

    A theory is developed for the Faraday rotation of light from a monolayer of charged magnetic nanoparticles at an electrified liquid-liquid interface. The polarization fields of neighboring nanoparticles enhance the Faraday rotation. At such interfaces, and for realistic sizes and charges of nanoparticles, their adsorption-desorption can be controlled with a voltage variationFaraday rotation. A calculation based on the Maxwell-Garnett theory predicts that the corresponding redistribution of 40 nm nanoparticles of yttrium iron garnet can switch a cavity with a quality factor larger than 10(4) for light of wavelength 500 nm at normal incidence.

  16. Fatty acids are rapidly delivered to and extracted from membranes by methyl-beta-cyclodextrin.

    Science.gov (United States)

    Brunaldi, Kellen; Huang, Nasi; Hamilton, James A

    2010-01-01

    We performed detailed biophysical studies of transfer of long-chain fatty acids (FAs) from methyl-beta-CD (MBCD) to model membranes (egg-PC vesicles) and cells and the extraction of FA from membranes by MBCD. We used i) fluorescein phosphatidylethanolamine to detect transfer of FA anions arriving in the outer membrane leaflet; ii) entrapped pH dyes to measure pH changes after FA diffusion (flip-flop) across the lipid bilayer; and iii) soluble fluorescent-labeled FA binding protein to measure the concentration of unbound FA in water. FA dissociated from MBCD, bound to the membrane, and underwent flip-flop within milliseconds. In the presence of vesicles, MBCD maintained the aqueous concentration of unbound FA at low levels comparable to those measured with albumin. In studies with cells, addition of oleic acid (OA) complexed with MBCD yielded rapid (seconds) dose-dependent OA transport into 3T3-L1 preadipocytes and HepG2 cells. MBCD extracted OA from cells and model membranes rapidly at concentrations exceeding those required for OA delivery but much lower than concentrations commonly used for extracting cholesterol. Compared with albumin, MBCD can transfer its entire FA load and is less likely to extract cell nutrients and to introduce impurities.

  17. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications.

    Directory of Open Access Journals (Sweden)

    Selvaraju Gayathri Devi

    Full Text Available A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely "powdered glass method" from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil with high purity (A260/280: 1.76 ± 0.05 and reduced humic substances (A340: 0.047 ± 0.03. The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method's applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666.

  18. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications.

    Science.gov (United States)

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely "powdered glass method" from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method's applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666).

  19. Evaluation of wavelet techniques in rapid extraction of ABR variations from underlying EEG.

    Science.gov (United States)

    De Silva, A C; Schier, M A

    2011-11-01

    The aim of this study is to analyse an effective wavelet method for denoising and tracking temporal variations of the auditory brainstem response (ABR). The rapid and accurate extraction of ABRs in clinical practice has numerous benefits, including reductions in clinical test times and potential long-term patient monitoring applications. One method of achieving rapid extraction is through the application of wavelet filtering which, according to earlier research, has shown potential in denoising signals with low signal-to-noise ratios. The research documented in this paper evaluates the application of three such wavelet approaches on a common set of ABR data collected from eight participants. We introduced the use of the latency-intensity curve of ABR wave V for performance evaluation of tracking temporal variations. The application of these methods to the ABR required establishing threshold functions and time windows as an integral part of the research. Results revealed that the cyclic-shift-tree-denoising performed superior compared to other tested approaches. This required an ensemble of only 32 epochs to extract a fully featured ABR compared to the 1024 epochs with conventional ABR extraction based on linear moving time averaging.

  20. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications

    Science.gov (United States)

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R.; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely “powdered glass method” from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method’s applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666). PMID:26167854

  1. New rapid DNA extraction method with Chelex from Venturia inaequalis spores.

    Science.gov (United States)

    Turan, Ceren; Nanni, Irene Maja; Brunelli, Agostino; Collina, Marina

    2015-08-01

    The objective of this study was to develop a rapid method to isolate DNA from Venturia inaequalis spores for use in diagnostic DNA mutation analysis. Chelex-100 resin was evaluated and compared with a well established DNA exctraction method, utilizing CTAB in order to have a robust comparison. In this research we demonstrated that Chelex-100 efficiently makes extraction of the DNA from V. inaequalis spores available for direct use in molecular analyses. Also, the quantity and quality of extracted DNA were shown to be adequate for PCR analysis. Comparatively, the quality of DNA samples isolated using Chelex method was better than those extracted using CTAB. In conclusion, the Chelex method is recommended for PCR experiments considering its simplicity and cost-effectiveness. Copyright © 2015. Published by Elsevier B.V.

  2. A RAPID DNA EXTRACTION METHOD IS SUCCESSFULLY APPLIED TO ITS-RFLP ANALYSIS OF MYCORRHIZAL ROOT TIPS

    Science.gov (United States)

    A rapid method for extracting DNA from intact, single root tips using a Xanthine solution was developed to handle very large numbers of analyses of ectomycorrhizas. By using an extraction without grinding we have attempted to bias the extraction towards the fungal DNA in the man...

  3. Dispersive liquid-liquid microextraction for the determination of vitamins D and K in foods by liquid chromatography with diode-array and atmospheric pressure chemical ionization-mass spectrometry detection.

    Science.gov (United States)

    Viñas, Pilar; Bravo-Bravo, María; López-García, Ignacio; Hernández-Córdoba, Manuel

    2013-10-15

    A simple and rapid method was developed using reversed-phase liquid chromatography (LC) with both diode array (DAD) and atmospheric pressure chemical ionization mass spectrometric (APCI-MS) detection, for the simultaneous analysis of the vitamins ergocalciferol (D2), cholecalciferol (D3), phylloquinone (K1), menaquinone-4 (K2) and a synthetic form of vitamin K, menadione (K3). The Taguchi experimental method, an orthogonal array design (OAD), was used to optimize an efficient and clean preconcentration step based on dispersive liquid-liquid microextraction (DLLME). A factorial design was applied with six factors and three levels for each factor, namely, carbon tetrachloride volume, methanol volume, aqueous sample volume, pH of sample, sodium chloride concentration and time of the centrifugation step. The DLLME optimized procedure consisted of rapidly injecting 3 mL of acetonitrile (disperser solvent) containing 150 µL carbon tetrachloride (extraction solvent) into the aqueous sample, thereby forming a cloudy solution. Phase separation was performed by centrifugation, and the sedimented phase was evaporated with nitrogen, reconstituted with 50 µL of acetonitrile, and injected. The LC analyses were carried out using a mobile phase composed of acetonitrile, 2-propanol and water, under gradient elution. Quantification was carried out by the standard additions method. The APCI-MS spectra, in combination with UV spectra, permitted the correct identification of compounds in the food samples. The method was validated according to international guidelines and using a certified reference material. The validated method was applied for the analysis of vitamins D and K in infant foods and several green vegetables. There was little variability in the forms of vitamin K present in vegetables, with the most abundant vitamer in all the samples being phylloquinone, while menadione could not be detected. Conversely, cholecalciferol, which is present in food of animal origin, was

  4. Integration of phase separation with ultrasound-assisted salt-induced liquid-liquid microextraction for analyzing the fluoroquinones in human body fluids by liquid chromatography.

    Science.gov (United States)

    Wang, Huili; Gao, Ming; Wang, Mei; Zhang, Rongbo; Wang, Wenwei; Dahlgren, Randy A; Wang, Xuedong

    2015-03-15

    Herein, we developed a novel integrated device to perform phase separation based on ultrasound-assisted salt-induced liquid-liquid microextraction for determination of five fluoroquinones (FQs) in human body fluids. The integrated device consisted of three simple HDPE components used to separate the extraction solvent from the aqueous phase prior to retrieving the extractant. A series of extraction parameters were optimized using the response surface method based on central composite design. Optimal conditions consisted of 945μL acetone extraction solvent, pH 2.1, 4.1min stir time, 5.9g Na2SO4, and 4.0min centrifugation. Under optimized conditions, the limits of detection (at S/N=3) were 0.12-0.66μgL(-1), the linear range was 0.5-500μgL(-1) and recoveries were 92.6-110.9% for the five FQs extracted from plasma and urine. The proposed method has several advantages, such as easy construction from inexpensive materials, high extraction efficiency, short extraction time, and compatibility with HPLC analysis. Thus, this method shows excellent prospects for sample pretreatment and analysis of FQs in human body fluids. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Rapid detection of Ganoderma-infected oil palms by microwave ergosterol extraction with HPLC and TLC.

    Science.gov (United States)

    Muniroh, M S; Sariah, M; Zainal Abidin, M A; Lima, N; Paterson, R R M

    2014-05-01

    Detection of basal stem rot (BSR) by Ganoderma of oil palms was based on foliar symptoms and production of basidiomata. Enzyme-Linked Immunosorbent Assays-Polyclonal Antibody (ELISA-PAB) and PCR have been proposed as early detection methods for the disease. These techniques are complex, time consuming and have accuracy limitations. An ergosterol method was developed which correlated well with the degree of infection in oil palms, including samples growing in plantations. However, the method was capable of being optimised. This current study was designed to develop a simpler, more rapid and efficient ergosterol method with utility in the field that involved the use of microwave extraction. The optimised procedure involved extracting a small amount of Ganoderma, or Ganoderma-infected oil palm suspended in low volumes of solvent followed by irradiation in a conventional microwave oven at 70°C and medium high power for 30s, resulting in simultaneous extraction and saponification. Ergosterol was detected by thin layer chromatography (TLC) and quantified using high performance liquid chromatography with diode array detection. The TLC method was novel and provided a simple, inexpensive method with utility in the field. The new method was particularly effective at extracting high yields of ergosterol from infected oil palm and enables rapid analysis of field samples on site, allowing infected oil palms to be treated or culled very rapidly. Some limitations of the method are discussed herein. The procedures lend themselves to controlling the disease more effectively and allowing more effective use of land currently employed to grow oil palms, thereby reducing pressure to develop new plantations. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Carbon nanoparticle stabilised liquid|liquid micro-interfaces for electrochemically driven ion-transfer processes

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, Stuart M. [Department of Chemistry, University of Bath, Bath BA2 7AY (United Kingdom); Fletcher, Paul D.I.; Cui Zhenggang [Department of Physical Sciences, Chemistry and Physics, University of Hull, Hull HU6 7RX (United Kingdom); Opallo, Marcin [Institute of Physical Chemistry, Polish Academy of Sciences, ul. Kasprzaka 44/52, 01-224 Warsaw (Poland); Chen Jingyuan [Department of Applied Physics, University of Fukui, 3-9-1, Bunkyo, Fukui-shi 910-8507 (Japan); Marken, Frank [Department of Chemistry, University of Bath, Bath BA2 7AY (United Kingdom)], E-mail: F.Marken@bath.ac.uk

    2007-12-20

    Stabilised liquid|liquid interfaces between an organic 4-(3-phenylpropyl)-pyridine (PPP) phase and an aqueous electrolyte phase are obtained in the presence of suitable nanoparticles. The use of nanoparticulate stabilisers (ca. 30 nm diameter laponite or 9-18 nm diameter carbon) in 'Pickering' emulsion systems allows stable organic microdroplets to be formed and these are readily deposited onto conventional tin-doped indium oxide (ITO) electrodes. In contrast to the electrically insulating laponite nanoparticles, conducting carbon nanoparticles are shown to effectively catalyse the simultaneous electron transfer and ion transfer process at triple phase boundary junctions. Anion transfer processes between the aqueous and organic phase are driven electrochemically at the extensive triple phase junction carbon nanoparticle|4-(3-phenylpropyl)-pyridine|aqueous electrolyte. The organic phase consists of a redox active reagent 5,10,15,20-tetraphenyl-21H,23H-porphinato manganese(III) (MnTPP{sup +}), 5,10,15,20-tetraphenyl-21H,23H-porphinato iron(III) (FeTPP{sup +}), or proto-porphyrinato-IX iron(III) (hemin) dissolved in 4-(3-phenylpropyl)-pyridine (PPP). The composition of the aqueous electrolyte phase determines the reversible potential for the Nernstian anion transfer process. The methodology is shown to be versatile and, in future, could be applied more generally in liquid|liquid electroanalysis.

  7. Stability of thin emulsion film between two oil phases with a viscoelastic liquid-liquid interface.

    Science.gov (United States)

    Narsimhan, Ganesan

    2009-02-15

    The viscoelastic properties of adsorbed protein layer in food emulsions and foams are important in providing stability to such systems. Linear stability analysis for a protein stabilized aqueous film sandwiched between two semi-infinite oil phases with a viscoelastic liquid-liquid interface is presented. The interfacial dilatational and shear viscoelastic properties are described by Maxwell models. The aqueous film is found to be more stable for smaller values of dilatational (shear) relaxation times and larger values of interfacial dilatational (shear) viscosities. The asymptotic values of maximum growth coefficient for very large and very small values of interfacial dilatational (shear) viscosities were found to be independent of relaxation times and correspond to those for immobile and fully mobile liquid-liquid interfaces respectively. The aqueous film is shown to be more stable for larger viscosities of the oil phase with the maximum growth coefficient approaching zero as the ratio of viscosities of oil and aqueous phases approach very large values and an asymptotic value corresponding to that for a foam film for very small viscosity ratios.

  8. Polyethylene nano crystalsomes formed at a curved liquid/liquid interface.

    Science.gov (United States)

    Wang, Wenda; Staub, Mark C; Zhou, Tian; Smith, Derrick M; Qi, Hao; Laird, Eric D; Cheng, Shan; Li, Christopher Y

    2017-12-21

    Crystallization is incommensurate with nanoscale curved space due to the lack of three dimensional translational symmetry of the latter. Herein, we report the formation of single-crystal-like, nanosized polyethylene (PE) capsules using a miniemulsion solution crystallization method. The miniemulsion was formed at elevated temperatures using PE organic solution as the oil phase and sodium dodecyl sulfate as the surfactant. Subsequently, cooling the system stepwisely for controlled crystallization led to the formation of hollow, nanosized PE crystalline capsules, which are named as crystalsomes since they mimic the classical self-assembled structures such as liposome, polymersome and colloidosome. We show that the formation of the nanosized PE crystalsomes is driven by controlled crystallization at the curved liquid/liquid interface of the miniemulson droplet. The morphology, structure and mechanical properties of the PE crystalsomes were characterized using scanning electron microscopy, transmission electron microscopy, X-ray diffraction, and atomic force spectroscopy. Electron diffraction showed the single-crystal-like nature of the crystalsomes. The incommensurateness between the nanocurved interface and the crystalline packing led to reduced crystallinity and crystallite size of the PE crystalsome, as observed from the X-ray diffraction measurements. Moreover, directly quenching the emulsion below the spinodal line led to the formation of hierarchical porous PE crystalsomes due to the coupling of the PE crystallization and liquid/liquid phase separation. We anticipate that this unique crystalsome represents a new type of nanostructure that might be used as nanodrug carriers and ultrasound contrast agents.

  9. Mixing liquid-liquid stratified flows using transverse jets in cross flows

    Science.gov (United States)

    Wright, Stuart; Matar, Omar K.; Markides, Christos N.

    2017-11-01

    Low pipeline velocities in horizontal liquid-liquid flows lead to gravitationally-induced stratification. This results in flow situations that have no point where average properties can be measured. Inline mixing limits the stratification effect by forming unstable liquid-liquid dispersions. An experimental system is used to measure the mixing performance of various jet-in-cross-flow (JICF) configurations as examples of active inline mixers. The test section consists of a 8.5-m long ETFE pipe with a 50-mm diameter, which is refractive index-matched to both a 10 cSt silicone oil and a 51 wt% glycerol solution. This practice allows advanced laser-based optical techniques, namely PLIF and PIV/PTV, to be applied to these flows in order to measure the phase fractions and velocity fields, respectively. A volume of a fluid (VOF) CFD code is then used to simulate simple jet geometries and to demonstrate the breakup and dispersion capabilities of JICFs in stratified pipeline flows by predicting their mixing efficiency. These simulation results are contrasted with the experimental results to examine the effectiveness of these simulations in predicting the dispersion and breakup. Funding from Cameron/Schlumberger, and the TMF Consortium gratefully acknowledged.

  10. Experimental Evidence for a Liquid-Liquid Crossover in Deeply Cooled Confined Water

    Science.gov (United States)

    Cupane, Antonio; Fomina, Margarita; Piazza, Irina; Peters, Judith; Schirò, Giorgio

    2014-11-01

    In this work we investigate, by means of elastic neutron scattering, the pressure dependence of mean square displacements (MSD) of hydrogen atoms of deeply cooled water confined in the pores of a three-dimensional disordered SiO2 xerogel; experiments have been performed at 250 and 210 K from atmospheric pressure to 1200 bar. The "pressure anomaly" of supercooled water (i.e., a mean square displacement increase with increasing pressure) is observed in our sample at both temperatures; however, contrary to previous simulation results and to the experimental trend observed in bulk water, the pressure effect is smaller at lower (210 K) than at higher (250 K) temperature. Elastic neutron scattering results are complemented by differential scanning calorimetry data that put in evidence, besides the glass transition at about 170 K, a first-order-like endothermic transition occurring at about 230 K that, in view of the neutron scattering results, can be attributed to a liquid-liquid crossover. Our results give experimental evidence for the presence, in deeply cooled confined water, of a crossover occurring at about 230 K (at ambient pressure) from a liquid phase predominant at 210 K to another liquid phase predominant at 250 K; therefore, they are fully consistent with the liquid-liquid transition hypothesis.

  11. Rapid extraction of lexical tone phonology in Chinese characters: a visual mismatch negativity study.

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Wang

    Full Text Available BACKGROUND: In alphabetic languages, emerging evidence from behavioral and neuroimaging studies shows the rapid and automatic activation of phonological information in visual word recognition. In the mapping from orthography to phonology, unlike most alphabetic languages in which there is a natural correspondence between the visual and phonological forms, in logographic Chinese, the mapping between visual and phonological forms is rather arbitrary and depends on learning and experience. The issue of whether the phonological information is rapidly and automatically extracted in Chinese characters by the brain has not yet been thoroughly addressed. METHODOLOGY/PRINCIPAL FINDINGS: We continuously presented Chinese characters differing in orthography and meaning to adult native Mandarin Chinese speakers to construct a constant varying visual stream. In the stream, most stimuli were homophones of Chinese characters: The phonological features embedded in these visual characters were the same, including consonants, vowels and the lexical tone. Occasionally, the rule of phonology was randomly violated by characters whose phonological features differed in the lexical tone. CONCLUSIONS/SIGNIFICANCE: We showed that the violation of the lexical tone phonology evoked an early, robust visual response, as revealed by whole-head electrical recordings of the visual mismatch negativity (vMMN, indicating the rapid extraction of phonological information embedded in Chinese characters. Source analysis revealed that the vMMN was involved in neural activations of the visual cortex, suggesting that the visual sensory memory is sensitive to phonological information embedded in visual words at an early processing stage.

  12. Rapid extraction of lexical tone phonology in Chinese characters: a visual mismatch negativity study.

    Science.gov (United States)

    Wang, Xiao-Dong; Liu, A-Ping; Wu, Yin-Yuan; Wang, Peng

    2013-01-01

    In alphabetic languages, emerging evidence from behavioral and neuroimaging studies shows the rapid and automatic activation of phonological information in visual word recognition. In the mapping from orthography to phonology, unlike most alphabetic languages in which there is a natural correspondence between the visual and phonological forms, in logographic Chinese, the mapping between visual and phonological forms is rather arbitrary and depends on learning and experience. The issue of whether the phonological information is rapidly and automatically extracted in Chinese characters by the brain has not yet been thoroughly addressed. We continuously presented Chinese characters differing in orthography and meaning to adult native Mandarin Chinese speakers to construct a constant varying visual stream. In the stream, most stimuli were homophones of Chinese characters: The phonological features embedded in these visual characters were the same, including consonants, vowels and the lexical tone. Occasionally, the rule of phonology was randomly violated by characters whose phonological features differed in the lexical tone. We showed that the violation of the lexical tone phonology evoked an early, robust visual response, as revealed by whole-head electrical recordings of the visual mismatch negativity (vMMN), indicating the rapid extraction of phonological information embedded in Chinese characters. Source analysis revealed that the vMMN was involved in neural activations of the visual cortex, suggesting that the visual sensory memory is sensitive to phonological information embedded in visual words at an early processing stage.

  13. (Liquid + liquid) equilibrium for ternary mixtures of {l_brace}heptane + aromatic compounds + [EMpy][ESO{sub 4}]{r_brace} at T = 298.15 K

    Energy Technology Data Exchange (ETDEWEB)

    Mirkhani, S.A. [Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Vossoughi, M., E-mail: vosoughi@sharif.edu [Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Pazuki, G.R. [Department of Chemical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Safekordi, A.A. [Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Heydari, A.; Akbari, J. [Department of Chemistry, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Yavari, M. [Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2011-10-15

    Highlights: > This paper reports the LLE data of ternary systems {l_brace}heptane (1) + aromatic compounds (2) + [EMpy][ESO{sub 4}] (3){r_brace}. > The distribution coefficient and the selectivity were obtained from the experimental data. > The consistency of LLE data was successfully correlated with Othmer-Tobias and Hand equation. - Abstract: (Liquid + liquid) equilibrium (LLE) data for the ternary systems (heptane + toluene + 1-ethyl-3-methylpyridinium ethylsulfate) and (heptane + benzene + 1-ethyl-3-methylpyridinium ethylsulfate) were measured at T = 298.15 K and atmospheric pressure. The selectivity and aromatic distribution coefficients, calculated from the equilibrium data, were used to determine if this ionic liquid can be used as a potential extracting solvent for the separation of aromatic compounds from heptane. The consistency of tie-line data was ascertained by applying the Othmer-Tobias and Hand equations.

  14. Rapid green synthesis of silver nanoparticles and nanorods using Piper nigrum extract

    Energy Technology Data Exchange (ETDEWEB)

    Mohapatra, Bandita [Multifunctional Nanomaterials Laboratory, School of Basic and Applied Sciences, Guru Gobind Singh Indraprastha University, Dwarka, New Delhi 110078 (India); Kuriakose, Sini [Multifunctional Nanomaterials Laboratory, School of Basic and Applied Sciences, Guru Gobind Singh Indraprastha University, Dwarka, New Delhi 110078 (India); School of Basic and Applied Sciences, Guru Gobind Singh Indraprastha University, Dwarka, New Delhi 110078 (India); Mohapatra, Satyabrata, E-mail: smiuac@gmail.com [Multifunctional Nanomaterials Laboratory, School of Basic and Applied Sciences, Guru Gobind Singh Indraprastha University, Dwarka, New Delhi 110078 (India); School of Basic and Applied Sciences, Guru Gobind Singh Indraprastha University, Dwarka, New Delhi 110078 (India)

    2015-07-15

    Highlights: • Silver nanorods were synthesized by photoreduction using Piper nigrum extract. • The morphological and structural properties were studied by XRD and AFM. • Silver nanoparticles were formed at lower AgNO{sub 3} concentration. • Increase in AgNO{sub 3} concentration resulted in formation of silver nanorods. - Abstract: We report sun light driven rapid green synthesis of stable aqueous dispersions of silver nanoparticles and nanorods at room temperature using photoreduction of silver ions with Piper nigrum extract. Silver nanoparticles were formed within 3 min of sun light irradiation following addition of Piper nigrum extract to the AgNO{sub 3} solution. The effects of AgNO{sub 3} concentration and irradiation time on the formation and plasmonic properties of biosynthesized silver nanoparticles were studied using UV–visible absorption spectroscopy. The morphology and structure of silver nanoparticles were well characterized by atomic force microscopy (AFM) and X-ray diffraction (XRD). The size of Ag nanoparticles increased with increase in irradiation time, leading to the formation of anisotropic nanostructures. Increasing the AgNO{sub 3} concentration resulted in the formation of Ag nanorods. UV–visible absorption studies revealed the presence of surface plasmon resonance (SPR) peaks which red shift and broaden with increasing AgNO{sub 3} concentration. We have demonstrated a facile, energy efficient and rapid green synthetic route to synthesize stable aqueous dispersions of silver nanoparticles and nanorods.

  15. Phenological Metrics Extraction for Agricultural Land-use Types Using RapidEye and MODIS

    Science.gov (United States)

    Xu, Xingmei; Doktor, Daniel; Conrad, Christopher

    2016-04-01

    Crop phenology involves the various agricultural events, such as planting, emergence, flowering, development of fruit and harvest. These phenological stages of a crop contain essential information for practical agricultural management, crop productivity estimation, investigations of crop-weather relationships, and also play an important role in improving agricultural land-use classification. In this study, we used MODIS and RapidEye images to extract phenological metrics in central Germany between 2010 and 2014. The Best Index Slope Extraction algorithm was used to remove undesirable data noise from Normalized Difference Vegetation Index (NDVI) time series of both satellite data before fast Fourier transformation was applied. Metrics optimization for phenology of major crops in the study area (winter wheat, winter barley, winter oilseed rape and sugar beet) and validation were performed with intensive ground observations from the German Weather Service (2010-2014) and our own measurements of BBCH code (Biologische Bundesanstalt für Land- und Forstwirtschaft, Bundessortenamt und CHemische Industrie) (in 2014). We found that the dates with maximum NDVI have a close link to the heading stage of cereals (RMSE = 9.48 days for MODIS and RMSE = 13.55 days for RapidEye), and the dates of local half maximum during senescence period of winter crops was strongly related to ripeness stage (BBCH: 87) (RMSE = 8.87 days for MODIS and RMSE = 9.62 days for RapidEye). The root-mean-square errors (RMSE) of derived green up dates for both winter and summer crops were larger than 2 weeks, which was caused by limited number of good quality images during the winter season. Comparison between RapidEye and homogeneous MODIS pixels indicated that phenological metrics derived from both satellites were similar to the crop calendar in this region. We also investigated the influence of spatial aggregation of RapidEye-scale phenology to MODIS scale as well as the effect of decreasing the

  16. Solution processing of polymer semiconductor: Insulator blends-Tailored optical properties through liquid-liquid phase separation control

    KAUST Repository

    Hellmann, Christoph

    2014-12-17

    © 2014 Wiley Periodicals, Inc. It has been demonstrated that the 0-0 absorption transition of poly(3-hexylthiophene) (P3HT) in blends with poly(ethylene oxide) (PEO) could be rationally tuned through the control of the liquid-liquid phase separation process during solution deposition. Pronounced J-like aggregation behavior, characteristic for systems of a low exciton band width, was found for blends where the most pronounced liquid-liquid phase separation occurred in solution, leading to domains of P3HT and PEO of high phase purity. Since liquid-liquid phase separation could be readily manipulated either by the solution temperature, solute concentration, or deposition temperature, to name a few parameters, our findings promise the design from the out-set of semiconductor:insulator architectures of pre-defined properties by manipulation of the interaction parameter between the solutes as well as the respective solute:solvent system using classical polymer science principles.

  17. Determination of insecticides in water using in situ halide exchange reaction-assisted ionic liquid dispersive liquid-liquid microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Li, Songqing; Gao, Haixiang; Zhang, Jiaheng; Li, Yubo; Peng, Bing; Zhou, Zhiqiang

    2011-11-01

    A dispersive liquid-liquid microextraction (DLLME) method using in situ halide exchange reaction to form ionic liquid (IL) extraction phase was developed to determine four insecticides (i.e. methoxyfenozide, tetrachlorvinphos, thiamethoxam, and diafenthiuron) in water samples. The preconcentration procedure, followed by high-performance liquid chromatography and variable wavelength detectors (VWD), enabled the formation of the immiscible IL extraction phase; the insecticides were transferred into the IL phase simultaneously, which enhanced the efficiency and sufficiency, greatly shortening the operation time. The experimental parameters affecting the extraction efficiency including volume of extraction IL, extraction and centrifugation times, volume of the sample solution and exchanging reagent, and addition of organic solvent and salt were investigated and optimized. Under optimized conditions, the extractions yielded recoveries of the target analytes from 82 to 102%. The calibration curves were linear, and the correlation coefficient ranged from 0.9990 to 0.9999 under the concentration levels of 5-200 μg/L. The relative standard deviation (n=6) was 2.9-4.6%. The limits of detection (LODs) for the four insecticides were between 0.98 and 2.54 μg/L. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Application of rapid cloud point extraction method for trace cobalt analysis coupled with spectrophotometric determination

    Science.gov (United States)

    Wen, Xiaodong; He, Lei; Shi, Chunsheng; Deng, Qingwen; Wang, Jiwei; Zhao, Xia

    2013-11-01

    In this work, the analytical performance of conventional spectrophotometer was improved through the coupling of effective preconcentration method with spectrophotometric determination. Rapidly synergistic cloud point extraction (RS-CPE) was used to pre-concentrate ultra trace cobalt and firstly coupled with spectrophotometric determination. The developed coupling was simple, rapid and efficient. The factors influencing RS-CPE and spectrophotometer were optimized. Under the optimal conditions, the limit of detection (LOD) was 0.6 μg L-1, with sensitivity enhancement factor of 23. The relative standard deviation (RSD) for seven replicate measurements of 50 μg L-1 of cobalt was 4.3%. The recoveries for the spiked samples were in the acceptable range of 93.8-105%.

  19. Rapid, room-temperature synthesis of amorphous selenium/protein composites using Capsicum annuum L extract

    Energy Technology Data Exchange (ETDEWEB)

    Li Shikuo; Shen Yuhua; Xie Anjian; Yu Xuerong; Zhang Xiuzhen; Yang Liangbao; Li Chuanhao [School of Chemistry and Chemical Engineering, Anhui University, Hefei 230039 (China)

    2007-10-10

    We describe the formation of amorphous selenium ({alpha}-Se)/protein composites using Capsicum annuum L extract to reduce selenium ions (SeO{sub 3}{sup 2-}) at room temperature. The reaction occurs rapidly and the process is simple and easy to handle. A protein with a molecular weight of 30 kDa extracted from Capsicum annuum L not only reduces the SeO{sub 3}{sup 2-} ions to Se{sup 0}, but also controls the nucleation and growth of Se{sup 0}, and even participates in the formation of {alpha}-Se/protein composites. The size and shell thickness of the {alpha}-Se/protein composites increases with high Capsicum annuum L extract concentration, and decreases with low reaction solution pH. The results suggest that this eco-friendly, biogenic synthesis strategy could be widely used for preparing inorganic/organic biocomposites. In addition, we also discuss the possible mechanism of the reduction of SeO{sub 3}{sup 2-} ions by Capsicum annuum L extract.

  20. Liquid-liquid interfacial properties of a symmetrical Lennard-Jones binary mixture

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Ruiz, F. J.; Blas, F. J., E-mail: felipe@uhu.es [Laboratorio de Simulación Molecular y Química Computacional, CIQSO-Centro de Investigación en Química Sostenible and Departamento de Física Aplicada, Universidad de Huelva, 21007 Huelva (Spain); Moreno-Ventas Bravo, A. I. [Laboratorio de Simulación Molecular y Química Computacional, CIQSO-Centro de Investigación en Química Sostenible and Departamento de Geología, Universidad de Huelva, 21007 Huelva (Spain)

    2015-09-14

    We determine the interfacial properties of a symmetrical binary mixture of equal-sized spherical Lennard-Jones molecules, σ{sub 11} = σ{sub 22}, with the same dispersive energy between like species, ϵ{sub 11} = ϵ{sub 22}, but different dispersive energies between unlike species low enough to induce phase separation. We use the extensions of the improved version of the inhomogeneous long-range corrections of Janecek [J. Phys. Chem. B 110, 6264 (2006)], presented recently by MacDowell and Blas [J. Chem. Phys. 131, 074705 (2009)] and Martínez-Ruiz et al. [J. Chem. Phys. 141, 184701 (2014)], to deal with the interaction energy and microscopic components of the pressure tensor. We perform Monte Carlo simulations in the canonical ensemble to obtain the interfacial properties of the symmetrical mixture with different cut-off distances r{sub c} and in combination with the inhomogeneous long-range corrections. The pressure tensor is obtained using the mechanical (virial) and thermodynamic route. The liquid-liquid interfacial tension is also evaluated using three different procedures, the Irving-Kirkwood method, the difference between the macroscopic components of the pressure tensor, and the test-area methodology. This allows to check the validity of the recent extensions presented to deal with the contributions due to long-range corrections for intermolecular energy and pressure tensor in the case of binary mixtures that exhibit liquid-liquid immiscibility. In addition to the pressure tensor and the surface tension, we also obtain density profiles and coexistence densities and compositions as functions of pressure, at a given temperature. According to our results, the main effect of increasing the cut-off distance r{sub c} is to sharpen the liquid-liquid interface and to increase the width of the biphasic coexistence region. Particularly interesting is the presence of a relative minimum in the total density profiles of the symmetrical mixture. This minimum is related

  1. Ceria nanocubic-ultrasonication assisted dispersive liquid-liquid microextraction coupled with matrix assisted laser desorption/ionization mass spectrometry for pathogenic bacteria analysis.

    Science.gov (United States)

    Abdelhamid, Hani Nasser; Bhaisare, Mukesh L; Wu, Hui-Fen

    2014-03-01

    A new ceria (CeO2) nanocubic modified surfactant is used as the basis of a novel nano-based microextraction technique for highly sensitive detection of pathogenic bacteria (Pseudomonas aeruginosa and Staphylococcus aureus). The technique uses ultrasound enhanced surfactant-assisted dispersive liquid-liquid microextraction (UESA-DLLME) with and without ceria (CeO2) followed by matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS). In order to achieve high separation efficiency, we investigated the influential parameters, including extraction time of ultrasonication, type and volume of the extraction solvent and surfactant. Among various surfactants, the cationic surfactants can selectively offer better extraction efficiency on bacteria analysis than that of the anionic surfactants due to the negative charges of bacteria cell membranes. Extractions of the bacteria lysate from aqueous samples via UESA-DLLME-MALDI-MS were successfully achieved by using cetyltrimethyl ammonium bromide (CTAB, 10.0 µL, 1.0×10(-3) M) as surfactants in chlorobenzene (10.0 µL) and chloroform (10.0 µL) as the optimal extracting solvent for P. aeruginosa and S. aureus, respectively. Ceria nanocubic was synthesized, and functionalized with CTAB (CeO2@CTAB) and then characterized using transmission electron microscopy (TEM) and optical spectroscopy (UV and FTIR). CeO2@CTAB demonstrates high extraction efficiency, improve peaks ionization, and enhance resolution. The prime reasons for these improvements are due to the large surface area of nanoparticles, and its absorption that coincides with the wavelength of MALD