WorldWideScience

Sample records for random magnetic systems

  1. Magnet Systems

    Data.gov (United States)

    Federal Laboratory Consortium — Over the decades, Fermilab has been responsible for the design, construction, test and analysis of hundreds of conventional and superconducting accelerator magnets...

  2. Induced magnetization and power loss for a periodically driven system of ferromagnetic nanoparticles with randomly oriented easy axes

    Science.gov (United States)

    Denisov, S. I.; Lyutyy, T. V.; Pedchenko, B. O.; Hryshko, O. M.

    2016-07-01

    We study the effect of an elliptically polarized magnetic field on a system of noninteracting, single-domain ferromagnetic nanoparticles characterized by a uniform distribution of easy axis directions. Our main goal is to determine the average magnetization of this system and the power loss in it. In order to calculate these quantities analytically, we develop a general perturbation theory for the Landau-Lifshitz-Gilbert (LLG) equation and find its steady-state solution for small magnetic field amplitudes. On this basis, we derive the second-order expressions for the average magnetization and power loss, investigate their dependence on the magnetic field frequency, and analyze the role of subharmonic resonances resulting from the nonlinear nature of the LLG equation. For arbitrary amplitudes, the frequency dependence of these quantities is obtained from the numerical solution of this equation. The impact of transitions between different regimes of regular and chaotic dynamics of magnetization, which can be induced in nanoparticles by changing the magnetic field frequency, is examined in detail.

  3. Theory of Random Anisotropic Magnetic Alloys

    DEFF Research Database (Denmark)

    Lindgård, Per-Anker

    1976-01-01

    A mean-field-crystal-field theory is developed for random, multicomponent, anisotropic magnetic alloys. It is specially applicable to rare-earth alloys. A discussion is given of multicritical points and phase transitions between various states characterized by order parameters with different...... spatial directions or different ordering wave vectors. Theoretical predictions based on known parameters for the phase diagrams and magnetic moments for the binary rare-earth alloys of Tb, Dy, Ho, and Er, Tb-Tm, Nd-Pr, and pure double-hcp Nd agree qualitatively with the experimental observations....... Quantitative agreement can be obtained by increasing the interaction between different alloy elements, in particular for alloys with very different axial anisotropy, e.g., Tb-Tm. A model system consisting of a singlet-singlet and singlet-doublet alloy is discussed in detail. A simple procedure to include...

  4. SPS : the magnet system

    CERN Multimedia

    CERN Neyrac Films

    1974-01-01

    English version. Part of a series of films about the SPS. This one ois from May 1974 to December 1974. Roy Billinge, Vince Hatton explain about magnet system. Technical requirements, accuracy checks, installation, magnetic measurements, mechanical measurements. Discussion of a particular problem which can come from variation in the thickness of the vacuum chambers. Dipoles, quadrapoles and other speciality magnets. Necessity for close international cooperation to coordinate the work. Nice meeting sequence at end. (calculator on the table.)

  5. Introduction to magnetic random-access memory

    CERN Document Server

    Dieny, Bernard; Lee, Kyung-Jin

    2017-01-01

    Magnetic random-access memory (MRAM) is poised to replace traditional computer memory based on complementary metal-oxide semiconductors (CMOS). MRAM will surpass all other types of memory devices in terms of nonvolatility, low energy dissipation, fast switching speed, radiation hardness, and durability. Although toggle-MRAM is currently a commercial product, it is clear that future developments in MRAM will be based on spin-transfer torque, which makes use of electrons’ spin angular momentum instead of their charge. MRAM will require an amalgamation of magnetics and microelectronics technologies. However, researchers and developers in magnetics and in microelectronics attend different technical conferences, publish in different journals, use different tools, and have different backgrounds in condensed-matter physics, electrical engineering, and materials science. This book is an introduction to MRAM for microelectronics engineers written by specialists in magnetic mat rials and devices. It presents the bas...

  6. Magnetic support system

    NARCIS (Netherlands)

    Nijsse, G.J.P.; Spronck, J.W.

    1999-01-01

    There is described a support system enabling supporting an object such as a platform (1) free from vibration, in that bearing elements (50) have a stiffness (k) which at a working point (z0) equals zero. A bearing element (50) comprises two magnetic couplings (51, 52) provided by permanent magnets

  7. Magnetic Coordinate Systems

    Science.gov (United States)

    Laundal, K. M.; Richmond, A. D.

    2017-03-01

    Geospace phenomena such as the aurora, plasma motion, ionospheric currents and associated magnetic field disturbances are highly organized by Earth's main magnetic field. This is due to the fact that the charged particles that comprise space plasma can move almost freely along magnetic field lines, but not across them. For this reason it is sensible to present such phenomena relative to Earth's magnetic field. A large variety of magnetic coordinate systems exist, designed for different purposes and regions, ranging from the magnetopause to the ionosphere. In this paper we review the most common magnetic coordinate systems and describe how they are defined, where they are used, and how to convert between them. The definitions are presented based on the spherical harmonic expansion coefficients of the International Geomagnetic Reference Field (IGRF) and, in some of the coordinate systems, the position of the Sun which we show how to calculate from the time and date. The most detailed coordinate systems take the full IGRF into account and define magnetic latitude and longitude such that they are constant along field lines. These coordinate systems, which are useful at ionospheric altitudes, are non-orthogonal. We show how to handle vectors and vector calculus in such coordinates, and discuss how systematic errors may appear if this is not done correctly.

  8. Multiferroic Magnetic Spirals Induced by Random Magnetic Exchanges

    Science.gov (United States)

    Scaramucci, Andrea; Shinaoka, Hiroshi; Mostovoy, Maxim V.; Müller, Markus; Mudry, Christopher; Troyer, Matthias; Spaldin, Nicola A.

    2018-01-01

    Multiferroism can originate from the breaking of inversion symmetry caused by magnetic-spiral order. The usual mechanism for stabilizing a magnetic spiral is competition between magnetic exchange interactions differing by their range and sign, such as nearest-neighbor and next-nearest-neighbor interactions. In insulating compounds, it is unusual for these interactions to be both comparable in magnitude and of a strength that can induce magnetic ordering at room temperature. Therefore, the onset temperatures for multiferroism through this mechanism are typically low. By considering a realistic model for multiferroic YBaCuFeO5 , we propose an alternative mechanism for magnetic-spiral order, and hence for multiferroism, that occurs at much higher temperatures. We show, using Monte Carlo simulations and electronic structure calculations based on density functional theory, that the Heisenberg model on a geometrically nonfrustrated lattice with only nearest-neighbor interactions can have a spiral phase up to high temperature when frustrating bonds are introduced randomly along a single crystallographic direction as caused, e.g., by a particular type of chemical disorder. This long-range correlated pattern of frustration avoids ferroelectrically inactive spin-glass order. Finally, we provide an intuitive explanation for this mechanism and discuss its generalization to other materials.

  9. Random matrix theory in biological nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Lacelle, S

    1984-01-01

    The statistical theory of energy levels or random matrix theory is presented in the context of the analysis of chemical shifts of nuclear magnetic resonance (NMR) spectra of large biological systems. Distribution functions for the spacing between nearest-neighbor energy levels are discussed for uncorrelated, correlated, and random superposition of correlated energy levels. Application of this approach to the NMR spectra of a vitamin, an antibiotic, and a protein demonstrates the state of correlation of an ensemble of energy levels that characterizes each system. The detection of coherent and dissipative structures in proteins becomes feasible with this statistical spectroscopic technique. PMID:6478032

  10. Magnetic Resonance Force Microscopy System

    Data.gov (United States)

    Federal Laboratory Consortium — The Magnetic Resonance Force Microscopy (MRFM) system, developed by ARL, is the world's most sensitive nuclear magnetic resonance (NMR) spectroscopic analysis tool,...

  11. Soft-error tolerance and energy consumption evaluation of embedded computer with magnetic random access memory in practical systems using computer simulations

    Science.gov (United States)

    Nebashi, Ryusuke; Sakimura, Noboru; Sugibayashi, Tadahiko

    2017-08-01

    We evaluated the soft-error tolerance and energy consumption of an embedded computer with magnetic random access memory (MRAM) using two computer simulators. One is a central processing unit (CPU) simulator of a typical embedded computer system. We simulated the radiation-induced single-event-upset (SEU) probability in a spin-transfer-torque MRAM cell and also the failure rate of a typical embedded computer due to its main memory SEU error. The other is a delay tolerant network (DTN) system simulator. It simulates the power dissipation of wireless sensor network nodes of the system using a revised CPU simulator and a network simulator. We demonstrated that the SEU effect on the embedded computer with 1 Gbit MRAM-based working memory is less than 1 failure in time (FIT). We also demonstrated that the energy consumption of the DTN sensor node with MRAM-based working memory can be reduced to 1/11. These results indicate that MRAM-based working memory enhances the disaster tolerance of embedded computers.

  12. Random matrices, random processes and integrable systems

    CERN Document Server

    2011-01-01

    This book explores the remarkable connections between two domains that, a priori, seem unrelated: Random matrices (together with associated random processes) and integrable systems. The relations between random matrix models and the theory of classical integrable systems have long been studied. These appear mainly in the deformation theory, when parameters characterizing the measures or the domain of localization of the eigenvalues are varied. The resulting differential equations determining the partition function and correlation functions are, remarkably, of the same type as certain equations appearing in the theory of integrable systems. They may be analyzed effectively through methods based upon the Riemann-Hilbert problem of analytic function theory and by related approaches to the study of nonlinear asymptotics in the large N limit. Associated with studies of matrix models are certain stochastic processes, the "Dyson processes", and their continuum diffusion limits, which govern the spectrum in random ma...

  13. Random walks, random fields, and disordered systems

    CERN Document Server

    Černý, Jiří; Kotecký, Roman

    2015-01-01

    Focusing on the mathematics that lies at the intersection of probability theory, statistical physics, combinatorics and computer science, this volume collects together lecture notes on recent developments in the area. The common ground of these subjects is perhaps best described by the three terms in the title: Random Walks, Random Fields and Disordered Systems. The specific topics covered include a study of Branching Brownian Motion from the perspective of disordered (spin-glass) systems, a detailed analysis of weakly self-avoiding random walks in four spatial dimensions via methods of field theory and the renormalization group, a study of phase transitions in disordered discrete structures using a rigorous version of the cavity method, a survey of recent work on interacting polymers in the ballisticity regime and, finally, a treatise on two-dimensional loop-soup models and their connection to conformally invariant systems and the Gaussian Free Field. The notes are aimed at early graduate students with a mod...

  14. The Orthogonalization of Magnetic Systems

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Primdahl, Fritz; Brauer, Peter

    2001-01-01

    The construction of an orthogonal reference frame based on a set of three skew axes for a magnetic coil system and a magnetic sensor is discussed and presented. For a skew system, it is possible to define the coil axes and the magnetic axes as a dual set of axes that are linked to the system...

  15. Ferromagnetic clusters induced by a nonmagnetic random disorder in diluted magnetic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Bui, Dinh-Hoi [Institute of Research and Development, Duy Tan University, K7/25 Quang Trung, Danang (Viet Nam); Physics Department, Hue University’s College of Education, 34 Le Loi, Hue (Viet Nam); Phan, Van-Nham, E-mail: phanvannham@dtu.edu.vn [Institute of Research and Development, Duy Tan University, K7/25 Quang Trung, Danang (Viet Nam)

    2016-12-15

    In this work, we analyze the nonmagnetic random disorder leading to a formation of ferromagnetic clusters in diluted magnetic semiconductors. The nonmagnetic random disorder arises from randomness in the host lattice. Including the disorder to the Kondo lattice model with random distribution of magnetic dopants, the ferromagnetic–paramagnetic transition in the system is investigated in the framework of dynamical mean-field theory. At a certain low temperature one finds a fraction of ferromagnetic sites transiting to the paramagnetic state. Enlarging the nonmagnetic random disorder strength, the paramagnetic regimes expand resulting in the formation of the ferromagnetic clusters.

  16. Embedded Memory Hierarchy Exploration Based on Magnetic Random Access Memory

    Directory of Open Access Journals (Sweden)

    Luís Vitório Cargnini

    2014-08-01

    Full Text Available Static random access memory (SRAM is the most commonly employed semiconductor in the design of on-chip processor memory. However, it is unlikely that the SRAM technology will have a cell size that will continue to scale below 45 nm, due to the leakage current that is caused by the quantum tunneling effect. Magnetic random access memory (MRAM is a candidate technology to replace SRAM, assuming appropriate dimensioning given an operating threshold voltage. The write current of spin transfer torque (STT-MRAM is a known limitation; however, this has been recently mitigated by leveraging perpendicular magnetic tunneling junctions. In this article, we present a comprehensive comparison of spin transfer torque-MRAM (STT-MRAM and SRAM cache set banks. The non-volatility of STT-MRAM allows the definition of new instant on/off policies and leakage current optimizations. Through our experiments, we demonstrate that STT-MRAM is a candidate for the memory hierarchy of embedded systems, due to the higher densities and reduced leakage of MRAM.We demonstrate that adopting STT-MRAM in L1 and L2 caches mitigates the impact of higher write latencies and increased current draw due to the use of MRAM. With the correct system-on-chip (SoC design, we believe that STT-MRAM is a viable alternative to SRAM, which minimizes leakage current and the total power consumed by the SoC.

  17. Magnetic separation in microfluidic systems

    DEFF Research Database (Denmark)

    Smistrup, Kristian

    2007-01-01

    , and it is argued that it is a good measure, when comparing the performance of magnetic bead separators. It is described how numeric modelling is used to aid the design of microfluidic magnetic separation systems. An example of a design optimization study is given. A robust fabrication scheme has been developed...... for fabrication of silicon based systems. This fabrication scheme is explained, and it is shown how, it is applied with variations for several designs of magnetic separators. An experimental setup for magnetic separation experiments has been developed. It has been coupled with an image analysis program......This Ph.D. thesis presents theory, modeling, design, fabrication, experiments and results for microfluidic magnetic separators. A model for magnetic bead movement in a microfluidic channel is presented, and the limits of the model are discussed. The effective magnetic field gradient is defined...

  18. Spin Injection in Thermally Assisted Magnetic Random Access Memory

    National Research Council Canada - National Science Library

    Deak, James G

    2005-01-01

    An integrated thermal, micromagnetic, spin-momentum-transfer (SMT) model was developed to study the effect of SMT on the programming current required for thermally assisted magnetic random access memory (MRAM...

  19. LHC magnet quench protection system

    Energy Technology Data Exchange (ETDEWEB)

    Coull, L.; Hagedorn, D.; Remondino, V.; Rodriguez-Mateos, F. [European Organization for Nuclear Research, Geneva (Switzerland)

    1994-07-01

    The quench protection system for the superconducting magnets of the CERN Large Hadron Collider (LHC) is described. The system is based on the so called ``cold diode`` concept. In a group of series connected magnets if one magnet quenches then the magnetic energy of all the magnets will be dissipated in the quenched magnet so destroying it. This is avoided by by-passing the quenched magnet and then rapidly de-exciting the unquenched magnets. For the LHC machine it is foreseen to use silicon diodes situated inside the cryostat as by-pass elements--so called ``cold diodes``. The diodes are exposed to some 50 kGray of radiation during a 10 year operation life-time. The high energy density of the LHC magnets (500 kJ/m) coupled with the relatively slow propagation speed of a ``natural`` quench (10 to 20 m/s) can lead to excessive heating of the zone where the quench started and to high internal voltages. It is therefore necessary to detect quickly the incipient quench and fire strip heaters which spread the quench out more quickly over a large volume of the magnet. After a quench the magnet chain must be de-excited rapidly to avoid spreading the quench to other magnets and over-heating the by-pass diode. This is done by switching high-power energy-dump resistors in series with the magnets. The LHC main ring magnet will be divided into 16 electrically separated units which has important advantages.

  20. Tribology of magnetic storage systems

    Science.gov (United States)

    Bhushan, Bharat

    1992-01-01

    The construction and the materials used in different magnetic storage devices are defined. The theories of friction and adhesion, interface temperatures, wear, and solid-liquid lubrication relevant to magnetic storage systems are presented. Experimental data are presented wherever possible to support the relevant theories advanced.

  1. Classification of Magnetic Nanoparticle Systems

    DEFF Research Database (Denmark)

    Bogren, Sara; Fornara, Andrea; Ludwig, Frank

    2015-01-01

    This study presents classification of different magnetic single- and multi-core particle systems using their measured dynamic magnetic properties together with their nanocrystal and particle sizes. The dynamic magnetic properties are measured with AC (dynamical) susceptometry and magnetorelaxometry...... and the size parameters are determined from electron microscopy and dynamic light scattering. Using these methods, we also show that the nanocrystal size and particle morphology determines the dynamic magnetic properties for both single- and multi-core particles. The presented results are obtained from...

  2. Topology optimized permanent magnet systems

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian; Insinga, Andrea Roberto

    2017-01-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron...... and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a ΛcoolΛcool figure of merit of 0...

  3. Topology optimized permanent magnet systems

    Science.gov (United States)

    Bjørk, R.; Bahl, C. R. H.; Insinga, A. R.

    2017-09-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a Λcool figure of merit of 0.472 is reached, which is an increase of 100% compared to a previous optimized design.

  4. Magnetic Random Access Memory for Embedded Computing

    Science.gov (United States)

    2007-10-29

    is pointed in the direction of current flow then the resulting magnetic field is oriented like the fingers curled toward the palm . As suggested in the...and Johann Heyen Hinken. Dielectric properties of single crystals of Al2O3, LaAlO3, NdGaO3, SrTiO3 and MgO at cryogenic temperatures. IEEE

  5. Model C critical dynamics of random anisotropy magnets

    Energy Technology Data Exchange (ETDEWEB)

    Dudka, M [Institute for Condensed Matter Physics, National Acad. Sci. of Ukraine, UA-79011 Lviv (Ukraine); Folk, R [Institut fuer Theoretische Physik, Johannes Kepler Universitaet Linz, A-4040 Linz (Austria); Holovatch, Yu [Institute for Condensed Matter Physics, National Acad. Sci. of Ukraine, UA-79011 Lviv (Ukraine); Moser, G [Institut fuer Physik und Biophysik, Universitaet Salzburg, A-5020 Salzburg (Austria)

    2007-07-20

    We study the relaxational critical dynamics of the three-dimensional random anisotropy magnets with the non-conserved n-component order parameter coupled to a conserved scalar density. In the random anisotropy magnets, the structural disorder is present in the form of local quenched anisotropy axes of random orientation. When the anisotropy axes are randomly distributed along the edges of the n-dimensional hypercube, asymptotical dynamical critical properties coincide with those of the random-site Ising model. However the structural disorder gives rise to considerable effects for non-asymptotic critical dynamics. We investigate this phenomenon by a field-theoretical renormalization group analysis in the two-loop order. We study critical slowing down and obtain quantitative estimates for the effective and asymptotic critical exponents of the order parameter and scalar density. The results predict complex scenarios for the effective critical exponent approaching the asymptotic regime.

  6. Magnetic Thin Films for Perpendicular Magnetic Recording Systems

    Science.gov (United States)

    Sugiyama, Atsushi; Hachisu, Takuma; Osaka, Tetsuya

    In the advanced information society of today, information storage technology, which helps to store a mass of electronic data and offers high-speed random access to the data, is indispensable. Against this background, hard disk drives (HDD), which are magnetic recording devices, have gained in importance because of their advantages in capacity, speed, reliability, and production cost. These days, the uses of HDD extend not only to personal computers and network servers but also to consumer electronics products such as personal video recorders, portable music players, car navigation systems, video games, video cameras, and personal digital assistances.

  7. Magnetic excitations in rare earth systems

    Science.gov (United States)

    Jensen, Jens

    1982-10-01

    The observation of magnetic excitations, by means of inelastic neutron scattering, provides valuable information on the magnetic forces acting in rare-earth systems. The RPA (random-phase approximation) theory, developed into its final form in the early seventies, is now a widely used tool for analyzing the excitation spectra in systems with well-defined local moments. These excitations reflect both the dynamics of the single moments and the interactions of these moments with their surroundings. A discussion of the information which has been obtained from studies of the magnetic excitations in the rare-earth metal is presented. The emphasis is laid on Pr-metal which has attracted much interest in recent years. Recent progress in the investigation of rare-earth intermetallic compounds, like the Laves-phase and the CsCl-type-compounds and the rare-earth pnictides, is also condidered. Some aspects of the magnetic properties of the actinides can be understood in terms of a model of localized moments, and we include a discussion of USb, where the spin-wave spectrum contains direct evidence that the spins are ordered in a triple- q structure. The magnetic excitations may be coupled to the phonons and in the metallic systems they interact with the electron- hole excitations of the conduction electrons. Therefore the sound velocities and the effective mass of the conduction electrons can be strongly affected by the spin system. Recent developments within these areas are also reviewed.

  8. The magnet components database system

    Energy Technology Data Exchange (ETDEWEB)

    Baggett, M.J. (Brookhaven National Lab., Upton, NY (USA)); Leedy, R.; Saltmarsh, C.; Tompkins, J.C. (Superconducting Supercollider Lab., Dallas, TX (USA))

    1990-01-01

    The philosophy, structure, and usage MagCom, the SSC magnet components database, are described. The database has been implemented in Sybase (a powerful relational database management system) on a UNIX-based workstation at the Superconducting Super Collider Laboratory (SSCL); magnet project collaborators can access the database via network connections. The database was designed to contain the specifications and measured values of important properties for major materials, plus configuration information (specifying which individual items were used in each cable, coil, and magnet) and the test results on completed magnets. These data will facilitate the tracking and control of the production process as well as the correlation of magnet performance with the properties of its constituents. 3 refs., 10 figs.

  9. Magnetically coupled system for mixing

    Energy Technology Data Exchange (ETDEWEB)

    Miller, III, Harlan; Meichel, George; Legere, Edward; Malkiel, Edwin; Woods, Robert Paul; Ashley, Oliver; Katz, Joseph; Ward, Jason; Petersen, Paul

    2015-09-22

    The invention provides a mixing system comprising a magnetically coupled drive system and a foil for cultivating algae, or cyanobacteria, in an open or enclosed vessel. The invention provides effective mixing, low energy usage, low capital expenditure, and ease of drive system component maintenance while maintaining the integrity of a sealed mixing vessel.

  10. Nanoparticles for magnetic biosensing systems

    Science.gov (United States)

    Kurlyandskaya, G. V.; Novoselova, Iu. P.; Schupletsova, V. V.; Andrade, R.; Dunec, N. A.; Litvinova, L. S.; Safronov, A. P.; Yurova, K. A.; Kulesh, N. A.; Dzyuman, A. N.; Khlusov, I. A.

    2017-06-01

    The further development of magnetic biosensors requires a better understanding of the interaction between living systems and magnetic nanoparticles (MNPs). We describe our experience of fabrication of stable ferrofluids (FF) using electrostatic or steric stabilization of iron oxide MNPs obtained by laser target evaporation. Controlled amounts of FF were used for in vitro experiments with human mesenchymal stem cells. Their morphofunctional responses in the Fe concentration range 2-1000 maximum tolerated dose revealed no cytotoxicity.

  11. The ALICE Magnetic System Computation.

    CERN Document Server

    Klempt, W; CERN. Geneva; Swoboda, Detlef

    1995-01-01

    In this note we present the first results from the ALICE magnetic system computation performed in the 3-dimensional way with the Vector Fields TOSCA code (version 6.5) [1]. To make the calculations we have used the IBM RISC System 6000-370 and 6000-550 machines combined in the CERN PaRC UNIX cluster.

  12. First principles modeling of magnetic random access memory devices (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Butler, W.H.; Zhang, X.; Schulthess, T.C.; Nicholson, D.M.; Oparin, A.B. [Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); MacLaren, J.M. [Department of Physics, Tulane University, New Orleans, Louisiana 70018 (United States)

    1999-04-01

    Giant magnetoresistance (GMR) and spin-dependent tunneling may be used to make magnetic random access memory devices. We have applied first-principles based electronic structure techniques to understand these effects and in the case of GMR to model the transport properties of the devices. {copyright} {ital 1999 American Institute of Physics.}

  13. Shear elastic modulus of magnetic gels with random distribution of magnetizable particles

    Science.gov (United States)

    Iskakova, L. Yu; Zubarev, A. Yu

    2017-04-01

    Magnetic gels present new type of composite materials with rich set of uniquie physical properties, which find active applications in many industrial and bio-medical technologies. We present results of mathematically strict theoretical study of elastic modulus of these systems with randomly distributed magnetizable particles in an elastic medium. The results show that an external magnetic field can pronouncedly increase the shear modulus of these composites.

  14. Metal-insulator transition of 2d electron gas in a random magnetic field

    CERN Document Server

    Wang, X R; Liu, D Z

    1999-01-01

    We study the metal-insulator transition of a two-dimensional electron gas in the presence of a random magnetic field from the localization property. The localization length is directly calculated using a transfer matrix technique and finite size scaling analysis. We argue that there is a metal-insulator transition in such a system and show strong numerical evidence that the system undergoes a disorder driven Kosterlitz-Thouless type metal-insulator transition. We will also discuss a mean field theory which maps the random field system into a two-dimensional XY-model. The vortex and antivortex excitations in the XY-model correspond to two different kinds of magnetic domains in the random field system.

  15. Nanoparticles for magnetic biosensing systems

    Energy Technology Data Exchange (ETDEWEB)

    Kurlyandskaya, G.V., E-mail: galina@we.lc.ehu.es [Universidad del País Vasco BCMaterials UPV-EHU, Leioa, 48940 Spain (Spain); Ural Federal University, Ekaterinburg, 620000 (Russian Federation); Novoselova, Iu.P. [Ural Federal University, Ekaterinburg, 620000 (Russian Federation); Schupletsova, V.V. [I.Kant Baltic Federal University, Kaliningrad, 23601 (Russian Federation); Andrade, R. [SGIker, ServiciosGenerales de Investigación, Universidad del País Vasco (UPV/EHU), Bilbao, 48080 Spain (Spain); Dunec, N.A.; Litvinova, L.S. [I.Kant Baltic Federal University, Kaliningrad, 23601 (Russian Federation); Safronov, A.P. [Ural Federal University, Ekaterinburg, 620000 (Russian Federation); Institute of Electrophysics, Ural Division, RAS, Ekaterinburg, 620016 (Russian Federation); Yurova, K.A. [I.Kant Baltic Federal University, Kaliningrad, 23601 (Russian Federation); Kulesh, N.A. [Ural Federal University, Ekaterinburg, 620000 (Russian Federation); Dzyuman, A.N. [Siberian State Medical University, Tomsk, 634050 (Russian Federation); Khlusov, I.A. [Siberian State Medical University, Tomsk, 634050 (Russian Federation); National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation)

    2017-06-01

    The further development of magnetic biosensors requires a better understanding of the interaction between living systems and magnetic nanoparticles (MNPs). We describe our experience of fabrication of stable ferrofluids (FF) using electrostatic or steric stabilization of iron oxide MNPs obtained by laser target evaporation. Controlled amounts of FF were used for in vitro experiments with human mesenchymal stem cells. Their morphofunctional responses in the Fe concentration range 2–1000 maximum tolerated dose revealed no cytotoxicity. - Highlights: • Stable ferrofluids (FF) were obtained using electrostatic or steric stabilization of iron oxide MNPs obtained by laser target evaporation. • Controlled amounts of FF were used for in vitro experiments with human mesenchymal stem cells. • Cells morphofunctional response in the Fe concentration range 2–1000 maximum tolerated dose revealed no cytotoxicity. • The results can be used for magnetic biosensoring, as well as for an addressed design of cell delivery systems.

  16. The effects of random field at surface on the magnetic properties in the Ising nanotube and nanowire

    Science.gov (United States)

    Kaneyoshi, T.

    2016-12-01

    The phase diagrams and temperature dependences of total magnetization mT in two nanosystems (nanotube and nanowire) with a random magnetic field at the surface shell are studied by the uses of the effective-field theory with correlations. Some characteristic phenomena (reentrant phenomena and unconventional thermal variation of total magnetization) are found in the two systems. They are rather different between the two systems, which mainly come from the structural differences of the cores

  17. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    Science.gov (United States)

    Barangi, Mahmood; Erementchouk, Mikhail; Mazumder, Pinaki

    2016-08-01

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  18. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    Energy Technology Data Exchange (ETDEWEB)

    Barangi, Mahmood, E-mail: barangi@umich.edu; Erementchouk, Mikhail; Mazumder, Pinaki [Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109-2121 (United States)

    2016-08-21

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  19. TMX magnet system, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Wong, R.L.; Pedrotti, L.R.; Leavitt, G.A.; Waugh, A.F.; Chargin, A.K.; Calderon, M.O.

    1979-11-30

    The magnetic field design and the mechanical design of the TMX magnet system were previously reported by Chen and Hinkle. This paper is a summary of the work that has been accomplished in the two years since then.

  20. Magnetic localization and orientation of the capsule endoscope based on a random complex algorithm

    Directory of Open Access Journals (Sweden)

    He XQ

    2015-04-01

    Full Text Available Xiaoqi He,1 Zizhao Zheng,1,2 Chao Hu1 1Ningbo Institute of Technology, Zhejiang University, Ningbo, People's Republic of China; 2Taiyuan University of Science and Technology, Taiyuan, People's Republic of China Abstract: The development of the capsule endoscope has made possible the examination of the whole gastrointestinal tract without much pain. However, there are still some important problems to be solved, among which, one important problem is the localization of the capsule. Currently, magnetic positioning technology is a suitable method for capsule localization, and this depends on a reliable system and algorithm. In this paper, based on the magnetic dipole model as well as magnetic sensor array, we propose nonlinear optimization algorithms using a random complex algorithm, applied to the optimization calculation for the nonlinear function of the dipole, to determine the three-dimensional position parameters and two-dimensional direction parameters. The stability and the antinoise ability of the algorithm is compared with the Levenberg–Marquart algorithm. The simulation and experiment results show that in terms of the error level of the initial guess of magnet location, the random complex algorithm is more accurate, more stable, and has a higher “denoise” capacity, with a larger range for initial guess values. Keywords: wireless capsule endoscope, magnet, optimization 

  1. Microstructure and random magnetic anisotropy in Fe-Ni based nanocrystalline thin films

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Senoy; Anantharaman, M R [Department of Physics, Cochin University of Science and Technology, Cochin, India-682022 (India); Al-Harthi, S H; Al-Omari, I A [Department of Physics, College of Science, Sultan Qaboos University, PO Box 36, Postal Code 123, Muscat, Sultanate of Oman (Oman); Sakthikumar, D; Yoshida, Yasuhiko [Bio-Nano Electronics Research Centre, Department of Applied Chemistry, Toyo University, Kawagoe, Saitama 350-8585 (Japan); Ramanujan, R V [School of Materials Science and Engineering, Nanyang Avenue, Nanyang Technological University, Singapore 639798 (Singapore)], E-mail: senoythomas@yahoo.co.in, E-mail: mra@cusat.ac.in

    2008-08-07

    Nanocrystalline Fe-Ni thin films were prepared by partial crystallization of vapour deposited amorphous precursors. The microstructure was controlled by annealing the films at different temperatures. X-ray diffraction, transmission electron microscopy and energy dispersive x-ray spectroscopy investigations showed that the nanocrystalline phase was that of Fe-Ni. Grain growth was observed with an increase in the annealing temperature. X-ray photoelectron spectroscopy observations showed the presence of a native oxide layer on the surface of the films. Scanning tunnelling microscopy investigations support the biphasic nature of the nanocrystalline microstructure that consists of a crystalline phase along with an amorphous phase. Magnetic studies using a vibrating sample magnetometer show that coercivity has a strong dependence on grain size. This is attributed to the random magnetic anisotropy characteristic of the system. The observed coercivity dependence on the grain size is explained using a modified random anisotropy model.

  2. Realistic finite temperature simulations of magnetic systems using quantum statistics

    Science.gov (United States)

    Bergqvist, Lars; Bergman, Anders

    2018-01-01

    We have performed realistic atomistic simulations at finite temperatures using Monte Carlo and atomistic spin dynamics simulations incorporating quantum (Bose-Einstein) statistics. The description is much improved at low temperatures compared to classical (Boltzmann) statistics normally used in these kind of simulations, while at higher temperatures the classical statistics are recovered. This corrected low-temperature description is reflected in both magnetization and the magnetic specific heat, the latter allowing for improved modeling of the magnetic contribution to free energies. A central property in the method is the magnon density of states at finite temperatures, and we have compared several different implementations for obtaining it. The method has no restrictions regarding chemical and magnetic order of the considered materials. This is demonstrated by applying the method to elemental ferromagnetic systems, including Fe and Ni, as well as Fe-Co random alloys and the ferrimagnetic system GdFe3.

  3. Interaction effects in magnetic oxide nanoparticle systems

    Indian Academy of Sciences (India)

    The interaction effects in magnetic nanoparticle system were studied through a Monte Carlo simulation. The results of simulations were compared with two different magnetic systems, namely, iron oxide polymer nanocomposites prepared by polymerization over core and nanocrystalline cobalt ferrite thin films prepared by ...

  4. Design consideration for magnetically suspended flywheel systems

    Science.gov (United States)

    Anand, D.; Kirk, J. A.; Frommer, D. A.

    1985-01-01

    Consideration is given to the design, fabrication, and testing of a magnetically suspended flywheel system for energy storage applications in space. The device is the prototype of a system combining passive suspension of the flywheel plate by samarium cobalt magnets and active control in the radial direction using eight separate magnetic coils. The bearing assembly was machined from a nickel-iron alloy, and the machine parts are all hydrogen annealed. Slots in the magnetic plate allow four independent quadrants for control. The motor/generator component of the system is a brushless dc-permanent magnetic/ironless engine using electronic communication. The system has been tested at over 2500 rpm with satisfactory results. The system characteristics of the flywheel for application in low earth orbit (LEO) are given in a table.

  5. Random field Ising model in a uniform magnetic field: Ground states, pinned clusters and scaling laws.

    Science.gov (United States)

    Kumar, Manoj; Banerjee, Varsha; Puri, Sanjay

    2017-11-08

    In this paper, we study the random field Ising model (RFIM) in an external magnetic field h . A computationally efficient graph-cut method is used to study ground state (GS) morphologies in this system for three different disorder types: Gaussian, uniform and bimodal. We obtain the critical properties of this system and find that they are independent of the disorder type. We also study GS morphologies via pinned-cluster distributions, which are scale-free at criticality. The spin-spin correlation functions (and structure factors) are characterized by a roughness exponent [Formula: see text]. The corresponding scaling function is universal for all disorder types and independent of h.

  6. Dynamical properties of unconventional magnetic systems

    Energy Technology Data Exchange (ETDEWEB)

    Helgesen, G. [ed.

    1997-05-01

    The Advanced Study Institute addressed the current experimental and theoretical knowledge of the dynamical properties of unconventional magnetic systems including low-dimensional and mesoscopic magnetism, unconventional ground state, quantum magnets and soft matter. The main approach in this Advanced Study Institute was to obtain basic understanding of co-operative phenomena, fluctuations and excitations in the wide range unconventional magnetic systems now being fabricated or envisioned. The report contains abstracts for lectures, invited seminars and posters, together with a list of the 95 participants from 24 countries with e-mail addresses

  7. Modular transportable superconducting magnetic Energy Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lieurance, D.; Kimball, F.; Rix, C. [Martin Marietta Space Magnetics, San Diego, CA (United States)

    1994-12-31

    Design and cost studies were performed for the magnet components of mid-size (1-5 MWh), cold supported SMES systems using alternative configurations. The configurations studied included solenoid magnets, which required onsite assembly of the magnet system, and toroid and racetrack configurations which consisted of factory assembled modules. For each configuration, design concepts and cost information were developed for the major features of the magnet system including the conductor, electrical insulation, and structure. These studies showed that for mid-size systems, the costs of solenoid and toroid magnet configurations are comparable and that the specific configuration to be used for a given application should be based upon customer requirements such as limiting stray fields or minimizing risks in development or construction.

  8. Microfluidic biosensing systems using magnetic nanoparticles.

    Science.gov (United States)

    Giouroudi, Ioanna; Keplinger, Franz

    2013-09-09

    In recent years, there has been rapidly growing interest in developing hand held, sensitive and cost-effective on-chip biosensing systems that directly translate the presence of certain bioanalytes (e.g., biomolecules, cells and viruses) into an electronic signal. The impressive and rapid progress in micro- and nanotechnology as well as in biotechnology enables the integration of a variety of analytical functions in a single chip. All necessary sample handling and analysis steps are then performed within the chip. Microfluidic systems for biomedical analysis usually consist of a set of units, which guarantees the manipulation, detection and recognition of bioanalytes in a reliable and flexible manner. Additionally, the use of magnetic fields for performing the aforementioned tasks has been steadily gaining interest. This is because magnetic fields can be well tuned and applied either externally or from a directly integrated solution in the biosensing system. In combination with these applied magnetic fields, magnetic nanoparticles are utilized. Some of the merits of magnetic nanoparticles are the possibility of manipulating them inside microfluidic channels by utilizing high gradient magnetic fields, their detection by integrated magnetic microsensors, and their flexibility due to functionalization by means of surface modification and specific binding. Their multi-functionality is what makes them ideal candidates as the active component in miniaturized on-chip biosensing systems. In this review, focus will be given to the type of biosening systems that use microfluidics in combination with magnetoresistive sensors and detect the presence of bioanalyte tagged with magnetic nanoparticles.

  9. QUASI-RANDOM TESTING OF COMPUTER SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. V. Yarmolik

    2013-01-01

    Full Text Available Various modified random testing approaches have been proposed for computer system testing in the black box environment. Their effectiveness has been evaluated on the typical failure patterns by employing three measures, namely, P-measure, E-measure and F-measure. A quasi-random testing, being a modified version of the random testing, has been proposed and analyzed. The quasi-random Sobol sequences and modified Sobol sequences are used as the test patterns. Some new methods for Sobol sequence generation have been proposed and analyzed.

  10. Geometric magnetism in open quantum systems

    OpenAIRE

    Campisi, Michele; Denisov, Sergey; Hänggi, Peter

    2012-01-01

    An isolated classical chaotic system, when driven by the slow change of several parameters, responds with two reaction forces: geometric friction and geometric magnetism. By using the theory of quantum fluctuation relations we show that this holds true also for open quantum systems, and provide explicit expressions for those forces in this case. This extends the concept of Berry curvature to the realm of open quantum systems. We illustrate our findings by calculating the geometric magnetism o...

  11. Random dynamical systems, entropies and information

    CERN Document Server

    Serva, M

    1999-01-01

    Prediction of events is the challenge in many different disciplines, from meteorology to finance; the more this task is difficult, the more a system is general consensus on what should be the correct indicator for complexity is still not reached. In particular, this characterization is still lacking for systems whose time evolution is influenced by factors which are not under control and appear as random parameters or random noise. We show in this paper how to find the correct indicators for complexity in the information theory context. The crucial point is that the answer is twofold depending on the fact that the random parameters are measurable or not. The content of this apparently trivial observation has been often ignored in literature leading to paradoxical results. Predictability is obviously larger when the random parameters are measurable, nevertheless, in the contrary case, predictability improves when the unknown random parameters are time correlated.

  12. Random forest regression for magnetic resonance image synthesis.

    Science.gov (United States)

    Jog, Amod; Carass, Aaron; Roy, Snehashis; Pham, Dzung L; Prince, Jerry L

    2017-01-01

    By choosing different pulse sequences and their parameters, magnetic resonance imaging (MRI) can generate a large variety of tissue contrasts. This very flexibility, however, can yield inconsistencies with MRI acquisitions across datasets or scanning sessions that can in turn cause inconsistent automated image analysis. Although image synthesis of MR images has been shown to be helpful in addressing this problem, an inability to synthesize both T2-weighted brain images that include the skull and FLuid Attenuated Inversion Recovery (FLAIR) images has been reported. The method described herein, called REPLICA, addresses these limitations. REPLICA is a supervised random forest image synthesis approach that learns a nonlinear regression to predict intensities of alternate tissue contrasts given specific input tissue contrasts. Experimental results include direct image comparisons between synthetic and real images, results from image analysis tasks on both synthetic and real images, and comparison against other state-of-the-art image synthesis methods. REPLICA is computationally fast, and is shown to be comparable to other methods on tasks they are able to perform. Additionally REPLICA has the capability to synthesize both T2-weighted images of the full head and FLAIR images, and perform intensity standardization between different imaging datasets. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Contextuality in canonical systems of random variables.

    Science.gov (United States)

    Dzhafarov, Ehtibar N; Cervantes, Víctor H; Kujala, Janne V

    2017-11-13

    Random variables representing measurements, broadly understood to include any responses to any inputs, form a system in which each of them is uniquely identified by its content (that which it measures) and its context (the conditions under which it is recorded). Two random variables are jointly distributed if and only if they share a context. In a canonical representation of a system, all random variables are binary, and every content-sharing pair of random variables has a unique maximal coupling (the joint distribution imposed on them so that they coincide with maximal possible probability). The system is contextual if these maximal couplings are incompatible with the joint distributions of the context-sharing random variables. We propose to represent any system of measurements in a canonical form and to consider the system contextual if and only if its canonical representation is contextual. As an illustration, we establish a criterion for contextuality of the canonical system consisting of all dichotomizations of a single pair of content-sharing categorical random variables.This article is part of the themed issue 'Second quantum revolution: foundational questions'. © 2017 The Author(s).

  14. Contextuality in canonical systems of random variables

    Science.gov (United States)

    Dzhafarov, Ehtibar N.; Cervantes, Víctor H.; Kujala, Janne V.

    2017-10-01

    Random variables representing measurements, broadly understood to include any responses to any inputs, form a system in which each of them is uniquely identified by its content (that which it measures) and its context (the conditions under which it is recorded). Two random variables are jointly distributed if and only if they share a context. In a canonical representation of a system, all random variables are binary, and every content-sharing pair of random variables has a unique maximal coupling (the joint distribution imposed on them so that they coincide with maximal possible probability). The system is contextual if these maximal couplings are incompatible with the joint distributions of the context-sharing random variables. We propose to represent any system of measurements in a canonical form and to consider the system contextual if and only if its canonical representation is contextual. As an illustration, we establish a criterion for contextuality of the canonical system consisting of all dichotomizations of a single pair of content-sharing categorical random variables. This article is part of the themed issue `Second quantum revolution: foundational questions'.

  15. Magnetization behavior of nanocrystalline systems combining ferromagnetic and antiferromagnetic phases

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, J.; Wagner, W.; Svygenhoven, H. van [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Meier, J.; Doudin, B.; Ansermet, J.P. [Ecole Polytechnique Federale, Lausanne (Switzerland)

    1997-09-01

    The magnetic properties of nanostructured materials on the basis of Fe and Ni have been investigated with a SQUID magnetometer, complementary to the small-angle neutron scattering study reported in the same volume. Measurements of the coercive field in a temperature range from 5 to 300 K confirm the validity of the random anisotropy model for our nanostructured systems. Furthermore, we obtain information about the presence and distribution of the antiferromagnetic oxides, joining the ferromagnetic grains. (author) 2 figs., 3 refs.

  16. The Theory of Random Laser Systems

    CERN Document Server

    Xun Ya Jian

    2002-01-01

    Studies of random laser systems are a new direction with promising potential applications and theoretical interest. The research is based on the theories of localization and laser physics. So far, the research shows that there are random lasing modes inside the systems which is quite different from the common laser systems. From the properties of the random lasing modes, they can understand the phenomena observed in the experiments, such as multi-peak and anisotropic spectrum, lasing mode number saturation, mode competition and dynamic processes, etc. To summarize, this dissertation has contributed the following in the study of random laser systems: (1) by comparing the Lamb theory with the Letokhov theory, the general formulas of the threshold length or gain of random laser systems were obtained; (2) they pointed out the vital weakness of previous time-independent methods in random laser research; (3) a new model which includes the FDTD method and the semi-classical laser theory. The solutions of this model ...

  17. Chiral Disorder and Random Matrix Theory with Magnetism

    OpenAIRE

    Nowak, Maciej A.; Sadzikowski, Mariusz; Zahed, Ismail.

    2013-01-01

    We revisit the concept of chiral disorder in QCD in the presence of a QED magnetic field $|eH|$. Weak magnetism corresponds to $|eH|\\le 1/\\rho^2$ with $\\rho\\approx 1/3$\\,fm the vacuum instanton size, while strong magnetism the reverse. Asymptotics (ultra-strong magnetism) is in the realm of perturbative QCD. We analyze weak magnetism using the concept of the quark return probability in the diffusive regime of chiral disorder. The result is in agreement with expectations from chiral perturbati...

  18. Spin transport and magnetization dynamics in various magnetic systems

    Science.gov (United States)

    Zhang, Shulei

    The general theme of the thesis is the interplay between magnetization dynamics and spin transport. The main presentation is divided into three parts. The first part is devoted to deepening our understanding on magnetic damping of ferromagnetic metals, which is one of the long-standing issues in conventional spintronics that has not been completely understood. For a nonuniformly-magnetized ferromagnetic metal, we find that the damping is nonlocal and is enhanced as compared to that in the uniform case. It is therefore necessary to generalize the conventional Landau-Lifshitz-Gilbert equation to include the additional damping. In a different vein, the decay mechanism of the uniform precession mode has been investigated. We point out the important role of spin-conserving electron-magnon interaction in the relaxation process by quantitatively examining its contribution to the ferromagnetic resonance linewidth. In the second part, a transport theory is developed for magnons which, in addition to conduction electrons, can also carry and propagate spin angular momentum via the magnon current. We demonstrate that the mutual conversion of magnon current and spin current may take place at magnetic interfaces. We also predict a novel magnon-mediated electric drag effect in a metal/magnetic-insulator/metal trilayer structure. This study may pave the way to the new area of insulator-based spintronics. In the third part of thesis, particular attention is paid to the influence the spin orbit coupling on both charge and spin transport. We theoretically investigate magnetotransport anisotropy and the conversion relations of spin and charge currents in various magnetic systems, and apply our results to interpret recent experiments.

  19. Equilibrium magnetization and microstructure of the system of superparamagnetic interacting particles: numerical simulation

    CERN Document Server

    Pshenichnikov, A F

    2000-01-01

    The Monte Carlo method is used to study the equilibrium magnetization of a 3D system of superparamagnetic particles taking into account the steric and dipole-dipole interparticle interactions. Two types of systems are considered: magnetic fluids and solidified ferrocolloids containing randomly spatially distributed particles with negligible energy of magnetic anisotropy. The results of numerical simulations confirm the universality of Langevin susceptibility as a main dimensionless parameter determining the influence of interparticle interactions on the magnetization of the system for moderate values of the aggregation parameter. The obtained results are in good agreement with theoretical and experimental data. At large values of the aggregation parameter, the clustering of particles in magnetic fluids is observed resulting in a reduction of their magnetization as compared to solidified systems. It is shown that the magnetization of solidified systems can be well described by the modified effective field appr...

  20. Underwater Animal Monitoring Magnetic Sensor System

    KAUST Repository

    Kaidarova, Altynay

    2017-10-01

    Obtaining new insights into the behavior of free-living marine organisms is fundamental for conservation efforts and anticipating the impact of climate change on marine ecosystems. Despite the recent advances in biotelemetry, collecting physiological and behavioral parameters of underwater free-living animals remains technically challenging. In this thesis, we develop the first magnetic underwater animal monitoring system that utilizes Tunnel magnetoresistance (TMR) sensors, the most sensitive solid-state sensors today, coupled with flexible magnetic composites. The TMR sensors are composed of CoFeB free layers and MgO tunnel barriers, patterned using standard optical lithography and ion milling procedures. The short and long-term stability of the TMR sensors has been studied using statistical and Allan deviation analysis. Instrumentation noise has been reduced using optimized electrical interconnection schemes. We also develop flexible NdFeB-PDMS composite magnets optimized for applications in corrosive marine environments, and which can be attached to marine animals. The magnetic and mechanical properties are studied for different NdFeB powder concentrations and the performance of the magnetic composites for different exposure times to sea water is systematically investigated. Without protective layer, the composite magnets loose more than 50% of their magnetization after 51 days in seawater. The durability of the composite magnets can be considerably improved by using polymer coatings which are protecting the composite magnet, whereby Parylene C is found to be the most effective solution, providing simultaneously corrosion resistance, flexibility, and enhanced biocompatibility. A Parylene C film of 2μm thickness provides the sufficient protection of the magnetic composite in corrosive aqueous environments for more than 70 days. For the high level performance of the system, the theoretically optimal position of the composite magnets with respect to the sensing

  1. Magnetic stimulation for stress urinary incontinence: study protocol for a randomized controlled trial

    National Research Council Canada - National Science Library

    Lim, Renly; Liong, Men Long; Leong, Wing Seng; Khan, Nurzalina Abdul Karim; Yuen, Kah Hay

    2015-01-01

    There is currently a lack of randomized, sham-controlled trials that are adequately powered, using validated outcomes, to allow for firm recommendations on the use of magnetic stimulation for stress urinary incontinence...

  2. Systems with randomly failing repairable components

    DEFF Research Database (Denmark)

    Der Kiureghian, Armen; Ditlevsen, Ove Dalager; Song, Junho

    2005-01-01

    Closed-form expressions are derived for the steady-state availability, mean rate of failure, mean duration of downtime and reliability of a general system with randomly and independently failing repairable components. Component failures are assumed to be homogeneous Poisson events in time and rep......, or reducing the mean duration of system downtime. Example applications to an electrical substation system demonstrate the use of the formulas developed in the paper....

  3. Towards a Decentralized Magnetic Indoor Positioning System

    Directory of Open Access Journals (Sweden)

    Zakaria Kasmi

    2015-12-01

    Full Text Available Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS, thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.

  4. Towards a Decentralized Magnetic Indoor Positioning System.

    Science.gov (United States)

    Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg

    2015-12-04

    Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.

  5. Magnetic Field Response Measurement Acquisition System

    Science.gov (United States)

    Woodward, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2007-01-01

    Magnetic field response sensors designed as passive inductor- capacit or circuits produce magnetic field responses whose harmonic frequenci es correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induc tion. A radio frequency antenna produces the time varying magnetic fi eld used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for disce rning changes in sensor's response frequency, resistance and amplitud e is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminat ing the need to have a data acquisition channel dedicated to each se nsor. The method does not require the sensors to be in proximity to a ny form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  6. INVESTIGATION OF INFLUENCE OF SEPARATOR MAGNETIC SYSTEM CONFIGURATION WITH PERMANENT MAGNETS ON MAGNETIC FIELD DISTRIBUTION IN WORKING AREA

    Directory of Open Access Journals (Sweden)

    J. Gerlici

    2017-04-01

    Full Text Available Purpose. To carry out research the influence of magnetic system configuration (shape and size of the permanent magnets on magnetic field spatial distribution in working area of new structure design magnetic separator with active front surface by numerical methods. Methodology. We have applied the magnetic field numerical simulation for permanent magnets system in absence of electrical current in magnetostatic approximation. We have solved the problem by using finite element method. Research of permanent magnets cross-sectional shape influence made in the two-dimensional formulation using software package Elcut. Research of magnetic field induction spatial (three-dimensional distribution in new construction magnetic separator working area is conducted using software package COMSOL Multiphysics 3.5a. Results. Magnetic flux density maximum in the immediate vicinity of permanent magnet surface provide magnets with spherical and trapezoidal cross-sectional shape. At a distance from pole surface, where the separation process working, magnetic field density produced by trapezoidal and spherical cross section magnets, substantially lower in comparison with rectangular magnets. Rectangular and rectangular with beveled corners cross-section shape magnets create approximately same magnetic field intensity not significantly different in weight. Analysis of the spatial distribution of magnetic field induction in the working area of a new construction magnetic separator has shown that a strong magnetic field with high magnetic flux density gradient value is formed in the interpolar working volume. Originality. For the first time research of magnetic flux density distribution in working area of new construction magnetic separator is conducted. Developed device feature is complex spatial distribution of magnetic field. Practical value. Results of research can be used for selection of rational parameters of separator magnetic system. Received results also can be

  7. Airborne electro-magnetic system

    Energy Technology Data Exchange (ETDEWEB)

    1977-09-01

    Tridem is a three-frequency in-phase and quadrature measuring, fixed configuration, airborne electromagnetic system developed by Scintrex. It has been in operation in Canada since 1975. It is expected that the system will be used in high resolution, multiple natural resource surveys for base metals, uranium, sand and gravel, coal, lignite, groundwater and civil engineering purposes.

  8. Magnetic hysteresis in two model spin systems

    OpenAIRE

    Rao, Madan; Krishnamurthy, HR; Pandit, Rahul

    1990-01-01

    A systematic study of hysteresis in model continuum and lattice spin systems is undertaken by constructing a statistical-mechanical theory wherein spatial fluctuations of the order parameter are incorporated. The theory is used to study the shapes and areas of the hysteresis loops as functions of the amplitude (Ho) and frequency (a) of the magnetic field. The response of the spin systems to a pulsed magnetic field is also studied. The continuum model that we study is a three-dimensional (CP2)...

  9. LHC II system sensitivity to magnetic fluids

    CERN Document Server

    Cotae, Vlad

    2005-01-01

    Experiments have been designed to reveal the influences of ferrofluid treatment and static magnetic field exposure on the photosynthetic system II, where the light harvesting complex (LHC II) controls the ratio chlorophyll a/ chlorophyll b (revealing, indirectly, the photosynthesis rate). Spectrophotometric measurement of chlorophyll content revealed different influences for relatively low ferrofluid concentrations (10-30 mul/l) in comparison to higher concentrations (70-100 mul/l). The overlapped effect of the static magnetic field shaped better the stimulatory ferrofluid action on LHC II system in young poppy plantlets.

  10. Autonomous Underwater Vehicle Magnetic Mapping System

    Science.gov (United States)

    Steigerwalt, R.; Johnson, R. M.; Trembanis, A. C.; Schmidt, V. E.; Tait, G.

    2012-12-01

    An Autonomous Underwater Vehicle (AUV) Magnetic Mapping (MM) System has been developed and tested for military munitions detection as well as pipeline locating, wreck searches, and geologic surveys in underwater environments. The system is comprised of a high sensitivity Geometrics G-880AUV cesium vapor magnetometer integrated with a Teledyne-Gavia AUV and associated Doppler enabled inertial navigation further utilizing traditional acoustic bathymetric and side scan imaging. All onboard sensors and associated electronics are managed through customized crew members to autonomously operate through the vehicles primary control module. Total field magnetic measurements are recorded with asynchronous time-stamped data logs which include position, altitude, heading, pitch, roll, and electrical current usage. Pre-planned mission information can be uploaded to the system operators to define data collection metrics including speed, height above seafloor, and lane or transect spacing specifically designed to meet data quality objectives for the survey. As a result of the AUVs modular design, autonomous navigation and rapid deployment capabilities, the AUV MM System provides cost savings over current surface vessel surveys by reducing the mobilization/demobilization effort, thus requiring less manpower for operation and reducing or eliminating the need for a surface support vessel altogether. When the system completes its mission, data can be remotely downloaded via W-LAN and exported for use in advanced signal processing platforms. Magnetic compensation software has been concurrently developed to accept electrical current measurements directly from the AUV to address distortions from permanent and induced magnetization effects on the magnetometer. Maneuver and electrical current compensation terms can be extracted from the magnetic survey missions to perform automated post-process corrections. Considerable suppression of system noise has been observed over traditional

  11. Progress with the Magnet Systems

    CERN Multimedia

    Miele, P

    B0 reaches 20.5 kA The B0 toroid model coil is a model of the BT coils with the same cross section and reduced length of 9 m. The same design and construction concepts have been implemented on B0 to validate the manufacturing technologies and concepts of the BT coils. The B0 realization is the result of a collaboration of CEA/INFN-LASA/CERN. A facility was built at CERN in order to test first the B0 model coil and thereafter the operation of the BT coils before installation. The infrastructure required to perform the tests includes a Helium refrigerator providing forced He flow for the cold mass and thermal shield cooling up to 100 g/s at 4.5 K and 60 K respectively; a 6V/24kA electrical system; the vacuum system able to provide 10-4 mbar; the safety system with appropriate quench protection unit and the systems for control and diagnostics. Because of its exceptional size, it is not feasible to assemble and test the BT as an integrated toroid on surface prior to underground installation. Therefore to repr...

  12. Open quantum systems and random matrix theory

    Science.gov (United States)

    Mulhall, Declan

    2015-01-01

    A simple model for open quantum systems is analyzed with random matrix theory. The system is coupled to the continuum in a minimal way. In this paper the effect on the level statistics of opening the system is seen. In particular the Δ3(L ) statistic, the width distribution and the level spacing are examined as a function of the strength of this coupling. The emergence of a super-radiant transition is observed. The level spacing and Δ3(L ) statistics exhibit the signatures of missed levels or intruder levels as the super-radiant state is formed.

  13. Testing the LHC magnet cryogenic systems

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    The magnets in the LHC will be cooled to 1.9 K (- 270.3°C). To keep this 27 km long machine at such a low temperatures requires one of the largest refrigeration systems in the world. These pictures show the cryogenics plant in the testing area.

  14. Characterization of Magnetic Tunnel Junctions For Spin Transfer Torque Magnetic Random Access Memory

    Science.gov (United States)

    Dill, Joshua Luchay

    This thesis details two experimental methods for quantifying magnetic tunnel junction behavior, namely write error rates and field modulated spin-torque ferromagnetic resonance. The former examines how reliably an applied spin-transfer torque can excite magnetization dynamics that lead to a reversal of magnetization direction while the latter studies steady state dynamics provided by an oscillating spin-transfer torque. These characterization techniques reveal write error rate behavior for a particular composition magnetic tunnel junction that qualitatively deviates from theoretical predictions. Possible origins of this phenomenon are also investigated with the field modulated spin-torque ferromagnetic resonance technique. By understanding the dynamics of magnetic moments predicted by theory, one can experimentally confirm or disprove these theories in order to accurately model and predict tunnel junction behavior. By having a better model for what factors are important in magnetization dynamics, one can optimize these factors in terms of improving magnetic tunnel junctions for their use as computer memory.

  15. A Portable Nuclear Magnetic Resonance Sensor System

    Directory of Open Access Journals (Sweden)

    R. Dykstra

    2008-04-01

    Full Text Available Nuclear Magnetic Resonance (NMR is a relatively complex technique and normally requires expensive equipment, however with advances in computing, electronics and permanent magnet technologies, NMR is becoming more feasible as a non-invasive tool for industry. The strength of NMR is its ability to probe at the molecular level and hence gain information about molecular structure, organization, abundance and orientation. This paper presents some of the work being undertaken in developing portable NMR systems for the non-destructive testing of materials such as polymer composites, rubber, timber and concrete.

  16. Effects from magnetic boundary conditions in superconducting-magnetic proximity systems

    Directory of Open Access Journals (Sweden)

    Thomas E. Baker

    2016-05-01

    Full Text Available A superconductor-magnetic proximity system displays singlet-triplet pair correlations in the magnetization as a function of inhomogeneities of the magnetic profile. We discuss how the magnetic boundary conditions affects differently the curvature and winding number of rotating magnetizations in the three commonly used structures to generate long range triplet components: an exchange spring, a helical structure and a misaligned magnetic multilayer. We conclude that the choice of the system is dictated by the goal one wishes to achieve in designing a spintronic device but note that only the exchange spring presently offers an experimentally realizable magnetic profile that is tunable.

  17. Cost comparisons for SSC magnet dependent systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-08-15

    An SSC Cost Estimating Task Force was appointed by the SSC Director in May, 1985. The charge to the task force was to perform a detailed review of costs for all superconducting magnet design styles that are under consideration for the SSC. Cost information on five magnet styles was reviewed in detail by the task force members. The basic cost information was developed by participating laboratories and by industry. Details of the procedure and analysis are presented in Chapter III. The purpose of this report is to provide a comparison of all SSC construction project cost information that is dependent on the various magnet styles. It is emphasized that the costs displayed in the tables of this report are not the total costs for an SSC construction project. Only those systems for which costs vary with magnet style are included. In Appendix E, current results are compared with the relevant parts of the 1984 SSC Reference Designs Study (RDS) cost estimate. Following the method used in the RDS, the costs that are developed here are non-site specific. The labor rates utilized are based on a national average for the various labor categories. The Conventional Systems costs for underground structures are derived from an extension of the ``median-site`` model as described in the RDS.

  18. Trial Application of Pulse-Field Magnetization to Magnetically Levitated Conveyor System

    Directory of Open Access Journals (Sweden)

    Yoshihito Miyatake

    2012-01-01

    Full Text Available Magnetically levitated conveyor system using superconductors is discussed. The system is composed of a levitated conveyor, magnetic rails, a linear induction motor, and some power supplies. In the paper, pulse-field magnetization is applied to the system. Then, the levitation height and the dynamics of the conveyor are controlled. The static and dynamic characteristics of the levitated conveyor are discussed.

  19. Trial Application of Pulse-Field Magnetization to Magnetically Levitated Conveyor System

    OpenAIRE

    Miyatake, Yoshihito; Komori, Mochimitsu; Asami, Ken-ichi; Sakai, Nobuo

    2012-01-01

    Magnetically levitated conveyor system using superconductors is discussed. The system is composed of a levitated conveyor, magnetic rails, a linear induction motor, and some power supplies. In the paper, pulse-field magnetization is applied to the system. Then, the levitation height and the dynamics of the conveyor are controlled. The static and dynamic characteristics of the levitated conveyor are discussed.

  20. Random magnetic field and quasiparticle transport in the mixed state of high- Tc cuprates.

    Science.gov (United States)

    Ye, J

    2001-01-08

    By a singular gauge transformation, the quasiparticle transport in the mixed state of high- Tc cuprates is mapped into a charge-neutral Dirac moving in short-range correlated random scalar and long-range correlated vector potential. A fully quantum mechanical approach to longitudinal and transverse thermal conductivities is presented. The semiclassical Volovik effect is presented in a quantum mechanical way. The quasiparticle scattering from the random magnetic field which was completely missed in all the previous semiclassical approaches is the dominant scattering mechanism at sufficient high magnetic field. The implications for experiments are discussed.

  1. Magnetic System for the CLAS12 Proposal

    Energy Technology Data Exchange (ETDEWEB)

    Statera, Marco [INFN, Ferrara (Italy); Contalbrigo, Marco M. [INFN, Ferrara (Italy); Pappalardo, Luciano Libero [INFN, Ferrara (Italy); Barion, Luca [INFN, Ferrara (Italy); Bertelli, S. [INFN, Ferrara (Italy); Ciullo, Giuseppe [INFN, Ferrara (Italy); Lenisa, Paolo [INFN, Ferrara (Italy)

    2013-06-01

    The conceptual design of a magnetic system for an experiment to measure the transverse spin effects in semi-inclusive Deep Inelastic Scattering (SIDIS) at 11 GeV with a transversely polarized target using the CLAS12 detector at Jefferson Lab is presented. A proposal has been submitted to study spin azimuthal asymmetries in SIDIS using an 11-GeV polarized electron beam from the upgraded CEBAF facility and the CLAS12 detector equipped with a transversely polarized target. The main focus of the experiment will be the measurement of transverse target single and double spin asymmetries in the reaction ep{up_arrow} -> ehX, where e is an electron, p{up_arrow} is transversely polarized proton, h is a meson (e.g., a pion or a kaon) and X is the undetected final state. The details of the conceptual design of the shielding magnetic system and transverse dipole are reported.

  2. Random field Ising model swept by propagating magnetic field wave: Athermal nonequilibrium phasediagram

    Science.gov (United States)

    Acharyya, Muktish

    2013-05-01

    The dynamical steady state behaviour of the random field Ising ferromagnet swept by a propagating magnetic field wave is studied at zero temperature by Monte Carlo simulation in two dimensions. The distribution of the random field is bimodal type. For a fixed set of values of the frequency, wavelength and amplitude of propagating magnetic field wave and the strength of the random field, four distinct dynamical steady states or nonequilibrium phases were identified. These four nonequilibrium phases are characterised by different values of structure factors. State or phase of first kind, where all spins are parallel (up). This phase is a frozen or pinned where the propagating field has no effect. The second one is the propagating type, where the sharp strips formed by parallel spins are found to move coherently. The third one is also propagating type, where the boundary of the strips of spins is not very sharp. The fourth kind shows no propagation of strips of magnetic spins, forming a homogeneous distribution of up and down spins. This is disordered phase. The existence of these four dynamical phases or modes depends on the value of the amplitude of propagating magnetic field wave and the strength of random (static) field. A phase diagram has also been drawn, in the plane formed by the amplitude of propagating field and the strength of random field. It is also checked that the existence of these dynamical phases is neither a finite size effect nor a transient phenomenon.

  3. Nuclear magnetic resonance in Kondo lattice systems

    Science.gov (United States)

    Curro, Nicholas J.

    2016-06-01

    Nuclear magnetic resonance has emerged as a vital tool to explore the fundamental physics of Kondo lattice systems. Because nuclear spins experience two different hyperfine couplings to the itinerant conduction electrons and to the local f moments, the Knight shift can probe multiple types of spin correlations that are not accessible via other techniques. The Knight shift provides direct information about the onset of heavy electron coherence and the emergence of the heavy electron fluid.

  4. Superconducting magnetic system with variable winding inductance

    Energy Technology Data Exchange (ETDEWEB)

    Baev, V.P.; Berezin, G.L.; Buyanov, Yu.L.; Kir`enin, I.A.; Trifonov, E.S.; Sheinkman, V.S. [Institute of High Temperature, Moscow (Russian Federation)

    1994-10-01

    An experimental magnetic system with an energy capacity of 0.5 MJ is described. The discharge current to a high-resistance load can be controlled by varying the winding inductance. The voltage across the load during a controlled discharge can reach 45 kV at a current of 1100 A with a coupling efficiency of 0.76 and a current multiplier of 1.3.

  5. Transport properties of a two-dimensional electron gas due to a spatially random magnetic field

    Science.gov (United States)

    Rushforth, A. W.; Gallagher, B. L.; Main, P. C.; Neumann, A. C.; Marrows, C. H.; Zoller, I.; Howson, M. A.; Hickey, B. J.; Henini, M.

    2000-02-01

    We have studied the magnetoresistance of a near-surface two-dimensional electron gas (2DEG) in the presence of a random magnetic field produced by CoPd multilayers deposited onto the surface of the heterostructure. This novel method allows us to switch the random field on and off by applying an external magnetic field and also to control the amplitude and correlation length of the random field by varying the growth parameters of the multilayers. The presence of the random field is confirmed by quenching of the Shubnikov-de Haas oscillations and we see an enhanced magnetoresistance which can be interpreted semi-classically. We also observe other unusual features which may be quantum in origin.

  6. Energy-Based Controller Design of Stochastic Magnetic Levitation System

    OpenAIRE

    Sun, Weiwei; Wang, Kaili; Nie, Congcong; Xie, Xuejun

    2017-01-01

    This paper investigates the control problem of magnetic levitation system, in which velocity feedback signal is influenced by stochastic disturbance. Firstly, single-degree-freedom magnetic levitation is regarded as an energy-transform action device. From the view of energy-balance relation, the magnetic levitation system is transformed into port-controlled Hamiltonian system model. Next, based on the Hamiltonian structure, the control law of magnetic levitation system is designed by applying...

  7. Failure Analysis of Storage Data Magnetic Systems

    Directory of Open Access Journals (Sweden)

    Ortiz–Prado A.

    2010-10-01

    Full Text Available This paper shows the conclusions about the corrosion mechanics in storage data magnetic systems (hard disk. It was done from the inspection of 198 units that were in service in nine different climatic regions characteristic for Mexico. The results allow to define trends about the failure forms and the factors that affect them. In turn, this study has analyzed the causes that led to mechanical failure and those due to deterioration by atmospheric corrosion. On the basis of the results obtained from the field sampling, demonstrates that the hard disk failure is fundamentally by mechanical effects. The deterioration by environmental effects were found in read-write heads, integrated circuits, printed circuit boards and in some of the electronic components of the controller card of the device, but not in magnetic storage surfaces. There fore, you can discard corrosion on the surface of the disk as the main kind of failure due to environmental deterioration. To avoid any inconvenience in the magnetic data storage system it is necessary to ensure sealing of the system.

  8. Novel Approach to Linear Accelerator Superconducting Magnet System

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, Vladimir; /Fermilab

    2011-11-28

    Superconducting Linear Accelerators include a superconducting magnet system for particle beam transportation that provides the beam focusing and steering. This system consists of a large number of quadrupole magnets and dipole correctors mounted inside or between cryomodules with SCRF cavities. Each magnet has current leads and powered from its own power supply. The paper proposes a novel approach to magnet powering based on using superconducting persistent current switches. A group of magnets is powered from the same power supply through the common, for the group of cryomodules, electrical bus and pair of current leads. Superconducting switches direct the current to the chosen magnet and close the circuit providing the magnet operation in a persistent current mode. Two persistent current switches were fabricated and tested. In the paper also presented the results of magnetic field simulations, decay time constants analysis, and a way of improving quadrupole magnetic center stability. Such approach substantially reduces the magnet system cost and increases the reliability.

  9. Magnetic field measuring system for remapping the ORIC magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Mosko, S.W.; Hudson, E.D.; Lord, R.S.; Hensley, D.C.; Biggerstaff, J.A.

    1977-01-01

    The Holifield Heavy Ion Research Facility will integrate a new 25 MV tandem electrostatic acccelerator into the existing cyclotron laboratory which includes the Oak Ridge Isochronous Cyclotron (ORIC). Computations of ion paths for beam injection from the new tandem into ORIC require field mapping in the regions traversed by the beam. Additional field data is also desired for the higher levels (approx.19 kG) now used for most heavy ion beams. The magnetic field measurement system uses 39 flip coil/current integrator sets with computer controlled data scanning. The coils are spaced radially at 1 inch intervals in an arm which can be rotated azimuthally in 2 degree increments. The entire flip coil assembly can be shifted to larger radii to measure fields beyond the pole boundary. Temperature stabilization of electronic circuitry permits a measurement resolution of +-1 gauss over a dynamic range of +-25,000 gauss. The system will process a scan of 8000 points in about one hour.

  10. Permanent magnet system to guide superparamagnetic particles

    Science.gov (United States)

    Baun, Olga; Blümler, Peter

    2017-10-01

    A new concept of using permanent magnet systems for guiding superparamagnetic nano-particles on arbitrary trajectories over a large volume is proposed. The basic idea is to use one magnet system which provides a strong, homogeneous, dipolar magnetic field to magnetize and orient the particles, and a second constantly graded, quadrupolar field, superimposed on the first, to generate a force on the oriented particles. In this configuration the motion of the particles is driven predominantly by the component of the gradient field which is parallel to the direction of the homogeneous field. As a result, particles are guided with constant force and in a single direction over the entire volume. The direction is simply adjusted by varying the angle between quadrupole and dipole. Since a single gradient is impossible due to Gauß' law, the other gradient component of the quadrupole determines the angular deviation of the force. However, the latter can be neglected if the homogeneous field is stronger than the local contribution of the quadrupole field. A possible realization of this idea is a coaxial arrangement of two Halbach cylinders. A dipole to evenly magnetize and orient the particles, and a quadrupole to generate the force. The local force was calculated analytically for this particular geometry and the directional limits were analyzed and discussed. A simple prototype was constructed to demonstrate the principle in two dimensions on several nano-particles of different size, which were moved along a rough square by manual adjustment of the force angle. The observed velocities of superparamagnetic particles in this prototype were always several orders of magnitude higher than the theoretically expected value. This discrepancy is attributed to the observed formation of long particle chains as a result of their polarization by the homogeneous field. The magnetic moment of such a chain is then the combination of that of its constituents, while its hydrodynamic radius

  11. The rate of separation of magnetic lines of force in a random magnetic field.

    Science.gov (United States)

    Jokipii, J. R.

    1973-01-01

    The mixing of magnetic lines of force, as represented by their rate of separation, as a function of distance along the magnetic field, is considered with emphasis on neighboring lines of force. This effect is particularly important in understanding the transport of charged particles perpendicular to the average magnetic field. The calculation is carried out in the approximation that the separation changes by an amount small compared with the correlation scale normal to the field, in a distance along the field of a few correlation scales. It is found that the rate of separation is very sensitive to the precise form of the power spectrum. Application to the interplanetary and interstellar magnetic fields is discussed, and it is shown that in some cases field lines, much closer together than the correlation scale, separate at a rate which is effectively as rapid as if they were many correlation lengths apart.

  12. Anharmonic Oscillations of a Spring-Magnet System inside a Magnetic Coil

    Science.gov (United States)

    Ladera, Celso L.; Donoso, Guillermo

    2012-01-01

    We consider the nonlinear oscillations of a simple spring-magnet system that oscillates in the magnetic field of an inductive coil excited with a dc current. Using the relations for the interaction of a coil and a magnet we obtain the motion equation of the system. The relative strengths of the terms of this equation can be adjusted easily by…

  13. Chiral magnetic effect in condensed matter systems

    Science.gov (United States)

    Li, Qiang; Kharzeev, Dmitri E.

    2016-12-01

    The chiral magnetic effect (CME) is the generation of electrical current induced by chirality imbalance in the presence of magnetic field. It is a macroscopic manifestation of the quantum chiral anomaly [S. L. Adler. Axial-vector vertex in spinor electrodynamics. Physical Review, 177, 2426 (1969), J. S. Bell and R. Jackiw. A PCAC puzzle: π 0 γγin the σ-model. Il Nuovo Cimento A, 60, 47-61 (1969)] in systems possessing charged chiral fermions. In quark-gluon plasma containing nearly massless quarks, the chirality imbalance is sourced by the topological transitions. In condensed matter systems, the chiral quasiparticles emerge in gapless semiconductors with two energy bands having pointlike degeneracies opening the path to the study of chiral anomaly [H. B. Nielsen and M. Ninomiya. The Adler-Bell-Jackiw anomaly and Weyl fermions in a crystal. Physics Letters B, 130, 389-396 (1983)]. Recently, these novel materials - so-called Dirac and Weyl semimetals have been discovered experimentally, are suitable for the investigation of the CME in condensed matter experiments. Here we report on the first experimental observation of the CME in a 3D Dirac semimetal ZrTe5 [Q. Li, D. E. Kharzeev, C. Zhang, Y. Huang, I. Pletikosić, A. V. Fedorov, R. D. Zhong, J. A. Schneeloch, G. D. Gu, and T. Valla. Chiral magnetic effect in ZrTe5. Nature Physics (2016) doi:10.1038/nphys3648].

  14. Magnetoresistance of a two-dimensional electron gas in a random magnetic field

    DEFF Research Database (Denmark)

    Smith, Anders; Taboryski, Rafael Jozef; Hansen, Luise Theil

    1994-01-01

    We report magnetoresistance measurements on a two-dimensional electron gas made from a high-mobility GaAs/AlxGa1-xAs heterostructure, where the externally applied magnetic field was expelled from regions of the semiconductor by means of superconducting lead grains randomly distributed...

  15. Magnetic Flux Density of Different Types of New Generation Magnetic Attachment Systems.

    Science.gov (United States)

    Akin, Hakan

    2015-07-01

    The purpose of this study was to analyze the static magnetic flux density of different types of new generation laser-welded magnetic attachments in the single position and the attractive position and to determine the effect of different corrosive environments on magnetic flux density. Magnetic flux densities of four magnetic attachment systems (Hyper slim, Hicorex slim, Dyna, and Steco) were measured with a gaussmeter. Then magnetic attachment systems were immersed in two different media, namely 1% lactic acid solution (pH 2.3), and 0.9% NaCl solution (pH 7.3). Magnetic flux densities of the attachment systems were measured with a gaussmeter after immersion to compare with measurements before immersion (α = 0.05). The data were statistically evaluated with one-way ANOVA, paired-samples t-test, and post hoc Tukey-Kramer multiple comparisons tests (α = 0.05). The highest magnetic flux density was found in Dyna magnets for both single and attractive positions. In addition, after the magnets were in the corrosive environments for 2 weeks, they had a significant decrease in magnetic flux density (p 0.05). The leakage flux of all the magnetic attachments did not exceed the WHO's guideline of 40 mT. The magnets exhibited a significant decrease in magnetic flux density after aging in corrosive environments including lactic acid and NaCl. © 2014 by the American College of Prosthodontists.

  16. Dipole magnet of the injection system for the SALO recirculator

    Science.gov (United States)

    Guk, I. S.; Dovbnya, A. N.; Kononenko, S. G.; Lyashchenko, V. N.; Mytsykov, A. Yu.; Romas'ko, V. P.; Tarasenko, A. S.; Shcherbinin, V. A.

    2012-07-01

    A design of a dipole magnet was developed for the injection system of the SALO recirculator. The constructed prototype magnet has a C-shaped structure with rectangular sections. The pole section is 100 × 100 mm; the aperture is 25 mm. Field distributions in the magnet at a gap induction of 0.05 and 0.2 T were measured. The effective length of the magnet and multipole components of the magnetic field were calculated.

  17. A portable magnetic induction measurement system (PIMS).

    Science.gov (United States)

    Cordes, Axel; Foussier, Jérôme; Pollig, Daniel; Leonhardt, Steffen

    2012-02-22

    For contactless monitoring of ventilation and heart activity, magnetic induction measurements are applicable. As the technique is harmless for the human body, it is well suited for long-term monitoring solutions, e.g., bedside monitoring, monitoring of home care patients, and the monitoring of persons in critical occupations. For such settings, a two-channel portable magnetic induction system has been developed, which is small and light enough to be fitted in a chair or bed. Because demodulation, control, and filtering are implemented on a front-end digital signal processor, a PC is not required (except for visualization/data storage during research and development). The system can be connected to a local area network (LAN) or wireless network (WiFi), allowing to connect several devices to a large monitoring system, e.g., for a residential home for the elderly or a hospital with low-risk patients not requiring standard ECG monitoring. To visualize data streams, a Qt-based (Qt-framework by Nokia, Espoo, Finland) monitoring application has been developed, which runs on Netbook computers, laptops, or standard PCs. To induce and measure the magnetic fields, external coils and amplifiers are required. This article describes the system and presents results for monitoring respiration and heart activity in a (divan) bed and for respiration monitoring in a chair. Planar configurations and orthogonal coil setups were examined during the measurement procedures. The measurement data were streamed over a LAN to a monitoring PC running Matlab (The MathWorks Inc, Natick, MA, USA).

  18. Glassy dynamics in randomly pinned particle systems

    Science.gov (United States)

    Phan, Anh; Schweizer, Kenneth

    We generalize the force-level, microscopic Elastically Collective Nonlinear Langevin Equation theory of activated relaxation in bulk hard sphere and thermal liquids to address the role of internal quenched disorder. So-called neutral confinement is considered where a subset of particles are randomly pinned and there is no change of equilibrium pair structure. As the pinned fraction grows, the cage scale dynamical constraints are intensified, resulting in the mobile particles becoming more localized, a larger glassy shear modulus, and an enhanced cage scale barrier. However, based on an approximate analysis of how quenched disorder modifies collective elastic field fluctuations, random pinning is predicted to effectively screen or localize the strain field associated with the longer range elastic component of the activation barrier, leading to an overall reduction of it with pinning fraction. The different response of the cage and elastic barriers to quenched disorder results in subtle predictions for how the alpha relaxation time varies with pinning fraction and system volume fraction. A semi-quantitative comparison with recent simulations of a pinned-mobile water model are consistent with the theory. Predictions are made for thermal molecular liquids.

  19. Development of superconducting magnet systems for HIFExperiments

    Energy Technology Data Exchange (ETDEWEB)

    Sabbi, Gian Luca; Faltens, A.; Leitzke, A.; Seidl, P.; Lund, S.; Martovets ky, N.; Chiesa, L.; Gung, C.; Minervini, J.; Schultz, J.; Goodzeit, C.; Hwang, P.; Hinson, W.; Meinke, R.

    2004-07-27

    The U.S. Heavy Ion Fusion program is developing superconducting focusing quadrupoles for near-term experiments and future driver accelerators. Following the fabrication and testing of several models, a baseline quadrupole design was selected and further optimized. The first prototype of the optimized design achieved a conductor-limited gradient of 132 T/m in a 70 mm bore, with measured field harmonics within 10 parts in 10{sup 4}. In parallel, a compact focusing doublet was fabricated and tested using two of the first-generation quadrupoles. After assembly in the cryostat, both magnets reached their conductor-limited quench current. Further optimization steps are currently underway to improve the performance of the magnet system and reduce its cost. They include the fabrication and testing of a new prototype quadrupole with reduced field errors as well as improvements of the cryostat design for the focusing doublet. The prototype units will be installed in the HCX beamline at LBNL, to perform accelerator physics experiments and gain operational experience. Successful results in the present phase will make superconducting magnets a viable option for the next generation of integrated beam experiments.

  20. Perturbation Solutions for Random Linear Structural Systems subject to Random Excitation using Stochastic Differential Equations

    DEFF Research Database (Denmark)

    Köyluoglu, H.U.; Nielsen, Søren R.K.; Cakmak, A.S.

    1994-01-01

    The paper deals with the first and second order statistical moments of the response of linear systems with random parameters subject to random excitation modelled as white-noise multiplied by an envelope function with random parameters. The method of analysis is basically a second order perturbat......The paper deals with the first and second order statistical moments of the response of linear systems with random parameters subject to random excitation modelled as white-noise multiplied by an envelope function with random parameters. The method of analysis is basically a second order...... for multi-degree-of-freedom (MDOF) systems and the method is illustrated for a single-degree-of-freedom (SDOF) oscillator. The results are compared to those of exact results for a random oscillator subject to white noise excitation with random intensity....

  1. Touchdown Ball-Bearing System for Magnetic Bearings

    Science.gov (United States)

    Kingsbury, Edward P.; Price, Robert; Gelotte, Erik; Singer, Herbert B.

    2003-01-01

    The torque-limited touchdown bearing system (TLTBS) is a backup mechanical-bearing system for a high-speed rotary machine in which the rotor shaft is supported by magnetic bearings in steady-state normal operation. The TLTBS provides ball-bearing support to augment or supplant the magnetic bearings during startup, shutdown, or failure of the magnetic bearings. The TLTBS also provides support in the presence of conditions (in particular, rotational acceleration) that make it difficult or impossible to control the magnetic bearings or in which the magnetic bearings are not strong enough (e.g., when the side load against the rotor exceeds the available lateral magnetic force).

  2. Random matrix theory, interacting particle systems and integrable systems

    CERN Document Server

    Forrester, Peter

    2014-01-01

    Random matrix theory is at the intersection of linear algebra, probability theory and integrable systems, and has a wide range of applications in physics, engineering, multivariate statistics and beyond. This volume is based on a Fall 2010 MSRI program which generated the solution of long-standing questions on universalities of Wigner matrices and beta-ensembles and opened new research directions especially in relation to the KPZ universality class of interacting particle systems and low-rank perturbations. The book contains review articles and research contributions on all these topics, in addition to other core aspects of random matrix theory such as integrability and free probability theory. It will give both established and new researchers insights into the most recent advances in the field and the connections among many subfields.

  3. Reduction of claustrophobia during magnetic resonance imaging: methods and design of the "CLAUSTRO" randomized controlled trial.

    Science.gov (United States)

    Enders, Judith; Zimmermann, Elke; Rief, Matthias; Martus, Peter; Klingebiel, Randolf; Asbach, Patrick; Klessen, Christian; Diederichs, Gerd; Bengner, Thomas; Teichgräber, Ulf; Hamm, Bernd; Dewey, Marc

    2011-02-10

    Magnetic resonance (MR) imaging has been described as the most important medical innovation in the last 25 years. Over 80 million MR procedures are now performed each year and on average 2.3% (95% confidence interval: 2.0 to 2.5%) of all patients scheduled for MR imaging suffer from claustrophobia. Thus, prevention of MR imaging by claustrophobia is a common problem and approximately 2,000,000 MR procedures worldwide cannot be completed due to this situation. Patients with claustrophobic anxiety are more likely to be frightened and experience a feeling of confinement or being closed in during MR imaging. In these patients, conscious sedation and additional sequences (after sedation) may be necessary to complete the examinations. Further improvements in MR design appear to be essential to alleviate this situation and broaden the applicability of MR imaging. A more open scanner configuration might help reduce claustrophobic reactions while maintaining image quality and diagnostic accuracy. We propose to analyze the rate of claustrophobic reactions, clinical utility, image quality, patient acceptance, and cost-effectiveness of an open MR scanner in a randomized comparison with a recently designed short-bore but closed scanner with 97% noise reduction. The primary aim of this study is thus to determine whether an open MR scanner can reduce claustrophobic reactions, thereby enabling more examinations of claustrophobic patients without incurring the safety issues associated with conscious sedation. In this manuscript we detail the methods and design of the prospective "CLAUSTRO" trial. This randomized controlled trial will be the first direct comparison of open vertical and closed short-bore MR systems in regards to claustrophobia and image quality as well as diagnostic utility. ClinicalTrials.gov: NCT00715806.

  4. Reduction of claustrophobia during magnetic resonance imaging: methods and design of the "CLAUSTRO" randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Teichgräber Ulf

    2011-02-01

    Full Text Available Abstract Background Magnetic resonance (MR imaging has been described as the most important medical innovation in the last 25 years. Over 80 million MR procedures are now performed each year and on average 2.3% (95% confidence interval: 2.0 to 2.5% of all patients scheduled for MR imaging suffer from claustrophobia. Thus, prevention of MR imaging by claustrophobia is a common problem and approximately 2,000,000 MR procedures worldwide cannot be completed due to this situation. Patients with claustrophobic anxiety are more likely to be frightened and experience a feeling of confinement or being closed in during MR imaging. In these patients, conscious sedation and additional sequences (after sedation may be necessary to complete the examinations. Further improvements in MR design appear to be essential to alleviate this situation and broaden the applicability of MR imaging. A more open scanner configuration might help reduce claustrophobic reactions while maintaining image quality and diagnostic accuracy. Methods/Design We propose to analyze the rate of claustrophobic reactions, clinical utility, image quality, patient acceptance, and cost-effectiveness of an open MR scanner in a randomized comparison with a recently designed short-bore but closed scanner with 97% noise reduction. The primary aim of this study is thus to determine whether an open MR scanner can reduce claustrophobic reactions, thereby enabling more examinations of claustrophobic patients without incurring the safety issues associated with conscious sedation. In this manuscript we detail the methods and design of the prospective "CLAUSTRO" trial. Discussion This randomized controlled trial will be the first direct comparison of open vertical and closed short-bore MR systems in regards to claustrophobia and image quality as well as diagnostic utility. Trial Registration ClinicalTrials.gov: NCT00715806

  5. A Two-Magnet System to Push Therapeutic Nanoparticles

    Science.gov (United States)

    Shapiro, Benjamin; Dormer, Kenneth; Rutel, Isaac B.

    2010-12-01

    Magnetic fields can be used to direct magnetically susceptible nanoparticles to disease locations: to infections, blood clots, or tumors. Any single magnet always attracts (pulls) ferro- or para-magnetic particles towards it. External magnets have been used to pull therapeutics into tumors near the skin in animals and human clinical trials. Implanting magnetic materials into patients (a feasible approach in some cases) has been envisioned as a means of reaching deeper targets. Yet there are a number of clinical needs, ranging from treatments of the inner ear, to antibiotic-resistant skin infections and cardiac arrhythmias, which would benefit from an ability to magnetically "inject", or push in, nanomedicines. We develop, analyze, and experimentally demonstrate a novel, simple, and effective arrangement of just two permanent magnets that can magnetically push particles. Such a system might treat diseases of the inner ear; diseases which intravenously injected or orally administered treatments cannot reach due to the blood-brain barrier.

  6. A permanent magnet system for Kibble balances

    Science.gov (United States)

    Li, Shisong; Bielsa, Franck; Stock, Michael; Kiss, Adrien; Fang, Hao

    2017-10-01

    The magnet is one of the fundamental elements in Kibble balances. The Kibble balance group at the Bureau International des Poids et Mesures (BIPM) proposed a permanent magnet with a radial field, which has been widely employed in other Kibble balance experiments. In this paper, we discuss a different method of operation for the BIPM-type magnet, i.e. only the lower half of the magnetic circuit is closed. The merit of such a magnet is its convenience for opening the air gap and adjusting the coil. A disadvantage is that it can yield a lower and sloped magnetic field profile with less shielding. In the approach described, high permeability yokes are used to flatten the magnetic profile, which has proven to be a novel and convenient approach for removing the nonuniformity of the magnetic profile due to magnet magnetization asymmetries. The performance of the half-closed BIPM magnet is evaluated using experimental measurements. The results show that the half-closed magnetic circuit retains most of the main features of the fully-closed magnet and is a good option for the early stages of Kibble balance operations. In addition, the profile change due to the coil current is predicted and experimentally verified with a bifilar coil. Related systematic effects are discussed for the Planck constant measurement.

  7. Superconducting magnet system for an experimental disk MHD facility

    NARCIS (Netherlands)

    Knoopers, H.G.; ten Kate, Herman H.J.; van de Klundert, L.J.M.; van de Klundert, L.J.M.

    1991-01-01

    A predesign of a split-pair magnet for a magnetohydrodynamic (MHD) facility for testing a 10-MW open-cycle disk or a 5-MW closed-cycle disk generator is presented. The magnet system consists of a NbTi and a Nb 3Sn section, which provide a magnetic field of 9 T in the active area of the MHD channel.

  8. Loss of long-range magnetic order in a nanoparticle assembly due to random anisotropy

    Science.gov (United States)

    Binns, C.; Howes, P. B.; Baker, S. H.; Marchetto, H.; Potenza, A.; Steadman, P.; Dhesi, S. S.; Roy, M.; Everard, M. J.; Rushforth, A.

    2008-02-01

    We have used soft x-ray photoemission electron microscopy (XPEEM) combined with x-ray magnetic circular dichroism (XMCD) and DC SQUID (superconducting quantum interference device) magnetometry to probe the magnetic ground state in Fe thin films produced by depositing size-selected gas-phase Fe nanoparticles with a diameter of 1.7 nm (~200 atoms) onto Si substrates. The depositions were carried out in ultrahigh vacuum conditions and thicknesses of the deposited film in the range 5-50 nm were studied. The magnetometry data are consistent with the film forming a correlated super-spin glass with a magnetic correlation length ~5 nm. The XPEEM magnetic maps from the cluster-assembled films were compared to those for a conventional thin Fe film with a thickness of 20 nm produced by a molecular beam epitaxy (MBE) source. Whereas a normal magnetic domain structure is observed in the conventional MBE thin film, no domain structure could be observed in any of the nanoparticle films down to the resolution limit of the XMCD based XPEEM (100 nm) confirming the ground state indicated by the magnetometry measurements. This observation is consistent with the theoretical prediction that an arbitrarily weak random anisotropy field will destroy long-range magnetic order.

  9. Loss of long-range magnetic order in a nanoparticle assembly due to random anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Binns, C [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Howes, P B [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Baker, S H [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Marchetto, H [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Diamond House, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Potenza, A [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Diamond House, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Steadman, P [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Diamond House, Chilton, Didcot, Oxfordshire OX11 0DE (United Kingdom); Dhesi, S S [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Roy, M [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Everard, M J [Department of Physics and Astronomy, University of Leicester, Leicester LE1 7RH (United Kingdom); Rushforth, A [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

    2008-02-06

    We have used soft x-ray photoemission electron microscopy (XPEEM) combined with x-ray magnetic circular dichroism (XMCD) and DC SQUID (superconducting quantum interference device) magnetometry to probe the magnetic ground state in Fe thin films produced by depositing size-selected gas-phase Fe nanoparticles with a diameter of 1.7 nm ({approx}200 atoms) onto Si substrates. The depositions were carried out in ultrahigh vacuum conditions and thicknesses of the deposited film in the range 5-50 nm were studied. The magnetometry data are consistent with the film forming a correlated super-spin glass with a magnetic correlation length {approx}5 nm. The XPEEM magnetic maps from the cluster-assembled films were compared to those for a conventional thin Fe film with a thickness of 20 nm produced by a molecular beam epitaxy (MBE) source. Whereas a normal magnetic domain structure is observed in the conventional MBE thin film, no domain structure could be observed in any of the nanoparticle films down to the resolution limit of the XMCD based XPEEM (100 nm) confirming the ground state indicated by the magnetometry measurements. This observation is consistent with the theoretical prediction that an arbitrarily weak random anisotropy field will destroy long-range magnetic order.

  10. Consolidation of the 45-Year Old PS Main Magnet System

    CERN Document Server

    Zickler, Thomas; Kalbreier, Wilhelm; Mess, Karl Hubert; Newborough, Antony

    2006-01-01

    After a major coil insulation breakdown on two of the 47-year-old CERN PS main magnets in 2003, an extensive magnet consolidation program has been launched. This article reviews the analysis of the magnet state be-fore the repair and the applied major improvements. An overview is given of the production of the new compo-nents, the actual refurbishment and the commissioning of the main magnet system after 18 months shutdown.

  11. Electron density studies on magnetic systems

    NARCIS (Netherlands)

    Boeije, M.F.J.

    2017-01-01

    In this thesis, the boundary conditions for the development of giant magnetocaloric materials
    are investigated. The magnetocaloric effect is found in magnetic materials, when
    they are subjected to an external magnetic field. This leads to abrupt magnetization
    changes that cause a

  12. Distortion of the Stoner-Wohlfarth Astroid by Perpendicular Polarizer in Magnetic Random Access Memory

    Science.gov (United States)

    Chang, Jui-Hang; Chang, Ching-Ray

    2012-02-01

    For a spin-transfer-torque (STT) magnetic random access memory (MRAM) with a perpendicular polarizer under an external in-plane magnetic field, a distorted astroid of critical strength of STT and field is derived from an one-dimensional effective free energy. The modified astroid not only separates the multiple stable states from the monostable state, but also delimit the region of dynamical stable state as the STT achieving a critical magnitude. Taking into account of the STT, multiple-step magnetization switching of the STT-MRAM has been investigated. We gave a phase diagram for the single-step, double-step, and triple-step switchings, which are observed at a certain range of the external field angle and of the current density.

  13. Magnetically assisted delivery of cells using a magnetic resonance imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Riegler, J [Centre for Advanced Biomedical Imaging (CABI), Department of Medicine and Institute of Child Health, University College London (UCL), London WC1E 6DD (United Kingdom); Allain, B [Centre for Medical Image Computing (CMIC) UCL, London WC1E 6BT (United Kingdom); Cook, R J [KCL Dental Institute, Biomaterials, Biomimetics and Biophotonics Group, C/O Floor 17 Tower Wing, Guy' s Hospital Campus, Great Maze Pond, London SE1 9RT (United Kingdom); Lythgoe, M F [Centre for Mathematics and Physics in the Life Sciences and Experimental Biology (CoMPLEX), UCL, London WC1E 6BT (United Kingdom); Pankhurst, Q A, E-mail: j.riegler@ucl.ac.uk [Davy-Faraday Research Laboratory, The Royal Institution of Great Britain, 21 Albemarle Street, London W1S 4BS (United Kingdom)

    2011-02-09

    A simple analytical model is presented which enables rapid interactive prediction and control of magnetically labelled cells in an arterial bifurcation using magnetic field gradients produced by a magnetic resonance imaging (MRI) system. This model is compared against experimental results for human mononuclear cells labelled with micrometre sized superparamagnetic iron oxide particles. Experimental and theoretical results highlight the importance of cell aggregation for magnetic targeting in a strong magnetic field. These predicted aggregates are confirmed via confocal endoscopy which allows the visualization of cell aggregates and their movement inside a vascular flow model in a 9.4 T preclinical MRI scanner.

  14. Dynamic Output Feedback Control for Nonlinear Networked Control Systems with Random Packet Dropout and Random Delay

    Directory of Open Access Journals (Sweden)

    Shuiqing Yu

    2013-01-01

    Full Text Available This paper investigates the dynamic output feedback control for nonlinear networked control systems with both random packet dropout and random delay. Random packet dropout and random delay are modeled as two independent random variables. An observer-based dynamic output feedback controller is designed based upon the Lyapunov theory. The quantitative relationship of the dropout rate, transition probability matrix, and nonlinear level is derived by solving a set of linear matrix inequalities. Finally, an example is presented to illustrate the effectiveness of the proposed method.

  15. Energy-Based Controller Design of Stochastic Magnetic Levitation System

    Directory of Open Access Journals (Sweden)

    Weiwei Sun

    2017-01-01

    Full Text Available This paper investigates the control problem of magnetic levitation system, in which velocity feedback signal is influenced by stochastic disturbance. Firstly, single-degree-freedom magnetic levitation is regarded as an energy-transform action device. From the view of energy-balance relation, the magnetic levitation system is transformed into port-controlled Hamiltonian system model. Next, based on the Hamiltonian structure, the control law of magnetic levitation system is designed by applying Lyapunov theory. Finally, the simulation verifies the correctness of the proposed results.

  16. Magnetic biosensor system to detect biological targets

    KAUST Repository

    Li, Fuquan

    2012-09-01

    Magneto-resistive sensors in combination with magnetic beads provide sensing platforms, which are small in size and highly sensitive. These platforms can be fully integrated with microchannels and electronics to enable devices capable of performing complex tasks. Commonly, a sandwich method is used that requires a specific coating of the sensor\\'s surface to immobilize magnetic beads and biological targets on top of the sensor. This paper concerns a micro device to detect biological targets using magnetic concentration, magnetic as well as mechanical trapping and magnetic sensing. Target detection is based on the size difference between bare magnetic beads and magnetic beads with targets attached. This method remedies the need for a coating layer and reduces the number of steps required to run an experiment. © 2012 IEEE.

  17. Magnetic Flux Density Feedback Control for Permanent Magnetic-Electromagnetic Hybrid Suspension System

    Directory of Open Access Journals (Sweden)

    Chen Qiang

    2017-01-01

    Full Text Available Permanent magnetic-electromagnetic hybrid suspension system can effectively reduce energy consumption and heat release of the system, but also increase the difficulty of suspension control because of the existence of permanent magnets. The traditional current feedback control method is not conducive to the stability of the system and is difficult to debug. In this paper, the models of permanent magnetic-electromagnetic hybrid suspension system based on current feedback and magnetic flux density feedback are established. The effects of current feedback and magnetic flux density feedback on the stability of the system are analyzed in theory and the advantages of flux density feedback are pointed out. The model of magnet flux feedback is simple and it can overcome the disadvantages of current feedback, which is beneficial to the stability of the system. The magnetic flux density feedback control of permanent magnetic-electromagnetic hybrid suspension system is realized by simulation and experiment. Control system performs well and is easy to debug.

  18. Magnetic force analysis and performance of a tri-stable piezoelectric energy harvester under random excitation

    Science.gov (United States)

    Leng, Yonggang; Tan, Dan; Liu, Jinjun; Zhang, Yuyang; Fan, Shengbo

    2017-10-01

    Recently, harvesting energy from environment has attracted lots of researchers' interests. Ambient vibrations are deemed as a promising power supply since it can be found almost everywhere. Piezoelectric effect has been exploited to convert mechanical energy to electricity. Nonlinearity techniques are favorable for improving the performance of piezoelectric energy harvesters. This paper focuses on a tri-stable piezoelectric energy harvester (TPEH) with two fixed external magnets. The lumped-parameter method is used to investigate the large-amplitude and broadband voltage response. A method based on equivalent magnetizing current theory is first applied to calculate the magnetic force and the potential function with triple wells. We find that this calculation method for magnetic force is more applicable for different magnet intervals compared with the magnetic dipoles method used before. Once the system parameters are chosen appropriately, large-amplitude interwell motion among three wells can be achieved. In our study, a filtered Gaussian noise within the frequency of 0-120 Hz is selected as harvester's excitation, which is similar with the realistic low-frequency vibration in environment. Simulation and experimental results demonstrate that the TPEH enhances the output voltage significantly compared to the conventional bi-stable piezoelectric energy harvester (BPEH). Also, the TPEH's frequency bandwidth is further broadened. Besides, it has been proved that the corresponding optimum magnet interval only changes slightly when the excitation intensity varies, therefore there is no need of adjusting the system parameters to meet practical conditions.

  19. Magnetic Correlations in Cold Atomic Systems

    Science.gov (United States)

    Pollet, Lode

    2017-04-01

    Magnetic correlations have recently been measured experimentally in cold atomic systems. These stretch over the entire system size fitting under the fermionic microscope realizing Heisenberg antiferromagnetism and constitute one of the greatest developments in recent years in this field. In the first part of the talk I review the experiment performed in the Bloch/Gross group by M. Boll et al. on Hubbard chains, demonstrating a simultaneous measurement of spin and charge. Correlations up to three sites have been discerned, allowing to extract an entropy density not greater than 0.5. I briefly comment on recent developments by this team. In the second part I move on to the two-dimensional case. The establishment of an antiferromagnetic Heisenberg phase in the Greiner lab paves the way to study open questions in the doped regime. Finally, I discuss the challenges to study FFLO instabilities for Hubbard systems with population imbalance as well as p-wave superfluidity by spin-nematic Fermi surface deformations and Ising antiferromagnetic transitions in explicitly SU(2) broken Hubbard models.

  20. Electromagnetically induced grating in a crystal of molecular magnets system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jibing, E-mail: liu0328@foxmail.com [College of Physics and Electronic Science and Institute for Advanced Materials, Hubei Normal University, Huangshi 435002 (China); Liu, Na; Shan, Chuanjia; Liu, Tangkun; Li, Hong [College of Physics and Electronic Science and Institute for Advanced Materials, Hubei Normal University, Huangshi 435002 (China); Zheng, Anshou, E-mail: zhengas-78@163.com [School of Mathematics and Physics, China University of Geosciences, Wuhan 430074 (China); Xie, Xiao-Tao, E-mail: xtxie1@gmail.com [School of Physics and Information Technology, Shaanxi Normal University, Xi' an 710119 (China)

    2016-07-15

    We investigate the response of the molecular system to the magnetic field modulation. Molecular magnets are subjected to a strong standing ac magnetic field and a weak probe magnetic field. The transmission and absorption of the weak probe magnetic field can be changed due to quantum coherence and the spatially modulating of the standing field. And a electromagnetically induced grating is formed in the crystal of molecular magnets via electromagnetically induced transparency (EIT). The diffraction efficiency of the grating can be adjusted efficiently by tuning the intensity of the standing wave field and the single photon detuning. - Highlights: • We provide a scheme to generate electromagnetically induced grating in a crystal of molecular magnets. • The transmission and absorption of the probe magnetic field can be changed by the standing field. • The efficiency of diffraction is depended on the intensity of coupling and the single photon detuning.

  1. Performance of Power Systems under Sustained Random Perturbations

    Directory of Open Access Journals (Sweden)

    Humberto Verdejo

    2014-01-01

    Full Text Available This paper studies linear systems under sustained additive random perturbations. The stable operating point of an electric power system is replaced by an attracting stationary solution if the system is subjected to (small random additive perturbations. The invariant distribution of this stationary solution gives rise to several performance indices that measure how well the system copes with the randomness. These indices are introduced, showing how they can be used for the optimal tuning of system parameters in the presence of noise. Results on a four-generator two-area system are presented and discussed.

  2. The Proximity Cryogenic System for the ATLAS Toroidal Magnets

    CERN Document Server

    Baynham, D Elwyn; Brown, G; Cragg, D; Crook, M; Haug, F; Mayri, C; Orlowska, A H; Passardi, Giorgio; Pengo, R; ten Kate, H H J; Rochford, J; Sole, D

    2002-01-01

    ATLAS is a very high-energy detector for the Large Hadron Collider (LHC) at CERN. The superconducting magnet used to provide the required magnetic field consists of four sub-systems: a central solenoid and a very large toroidal magnet comprising two end-cap magnets and the barrel toroid magnet. The associated cryogenic system, currently in the final specification and procurement phase has been sub-divided into three parts: internal, proximity and external. The internal cryogenics minimizes and extracts the heat loads to/from the 4.5 K cold mass and its thermal shields, while the proximity cryogenics takes the cooling capacity generated by the external common system and distributes it to the four magnets according to the various operating scenarios. Two independent proximity cryogenic systems have been designed taking into account the difference in cooling principle of the solenoid and the three toroids, respectively.

  3. The proximity cryogenic system for the ATLAS toroidal magnets

    Science.gov (United States)

    Haug, F.; Passardi, G.; Pengo, R.; ten Kate, H.; Baynham, E.; Bradshaw, T.; Brown, G.; Cragg, D.; Crook, M.; Orlowska, A. H.; Rochford, J.; Sole, D.; Mayri, C.

    2002-05-01

    ATLAS is a very high-energy detector for the Large Hadron Collider (LHC) at CERN. The superconducting magnet used to provide the required magnetic field consists of four sub-systems: a central solenoid and a very large toroidal magnet comprising two end-cap magnets and the barrel toroid magnet. The associated cryogenic system, currently in the final specification and procurement phase has been sub-divided into three parts: internal, proximity and external. The internal cryogenics minimizes and extracts the heat loads to/from the 4.5 K cold mass and its thermal shields, while the proximity cryogenics takes the cooling capacity generated by the external common system and distributes it to the four magnets according to the various operating scenarios. Two independent proximity cryogenic systems have been designed taking into account the difference in cooling principle of the solenoid and the three toroids, respectively.

  4. Empirical magnetic structure solution of frustrated spin systems.

    Science.gov (United States)

    Paddison, Joseph A M; Goodwin, Andrew L

    2012-01-06

    Frustrated magnetism plays a central role in the phenomenology of exotic quantum states. However, since the magnetic structures of frustrated systems are often aperiodic, there has been the problem that they cannot be determined by using traditional crystallographic techniques. Here we show that the magnetic component of powder neutron scattering data is actually sufficiently information-rich to drive magnetic structure solution for frustrated systems, including spin ices, spin liquids, and molecular magnets. Our methodology employs ab initio reverse Monte Carlo refinement, making informed use of an additional constraint that minimizes variance in local spin environments. The atomistic spin configurations obtained in this way not only reflect a magnetic structure "solution" but also reproduce the full three-dimensional magnetic scattering pattern.

  5. Accretion and magnetic field structure in AM Herculis systems

    Science.gov (United States)

    Wickramasinghe, D. T.; Ferrario, Lilia

    2000-04-01

    Detailed spectroscopic studies of the magnetic white dwarfs in the AM Herculis type systems have shown that in most systems the magnetic white dwarf has two dominant poles with field strengths that differ by a factor ˜1.5-2 indicating non dipolar field structures. In all but the highest field system AR UMa, phase locking appears to be maintained through magneto-static interactions between the magnetic field of the white dwarf and the dynamo generated magnetic field of the secondary star.

  6. A Magnetic Sensor System for Biological Detection

    KAUST Repository

    Li, Fuquan

    2015-05-01

    Magnetic biosensors detect biological targets through sensing the stray field of magnetic beads which label the targets. Commonly, magnetic biosensors employ the “sandwich” method to immobilize biological targets, i.e., the targets are sandwiched between a bio-functionalized sensor surface and bio-functionalized magnetic beads. This method has been used very successfully in different application, but its execution requires a rather elaborate procedure including several washing and incubation steps. This dissertation investigates a new magnetic biosensor concept, which enables a simple and effective detection of biological targets. The biosensor takes advantage of the size difference between bare magnetic beads and compounds of magnetic beads and biological targets. First, the detection of super-paramagnetic beads via magnetic tunnel junction (MTJ) sensors is implemented. Frequency modulation is used to enhance the signal-to-noise ratio, enabling the detection of a single magnetic bead. Second, the concept of the magnetic biosensor is investigated theoretically. The biosensor consists of an MTJ sensor, which detects the stray field of magnetic beads inside of a trap on top of the MTJ. A microwire between the trap and the MTJ is used to attract magnetic beads to the trapping well by applying a current to it. The MTJ sensor’s output depends on the number of beads inside the trap. If biological targets are in the sample solution, the beads will form bead compounds consisting of beads linked to the biological targets. Since bead compounds are larger than bare beads, the number of beads inside the trapping well will depend on the presence of biological targets. Hence, the output of the MTJ sensor will depend on the biological targets. The dependences of sensor signals on the sizes of the MTJ sensor, magnetic beads and biological targets are studied to find the optimum constellations for the detection of specific biological targets. The optimization is demonstrated

  7. A random dynamical systems perspective on stochastic resonance

    Science.gov (United States)

    Cherubini, Anna Maria; Lamb, Jeroen S. W.; Rasmussen, Martin; Sato, Yuzuru

    2017-07-01

    We study stochastic resonance in an over-damped approximation of the stochastic Duffing oscillator from a random dynamical systems point of view. We analyse this problem in the general framework of random dynamical systems with a nonautonomous forcing. We prove the existence of a unique global attracting random periodic orbit and a stationary periodic measure. We use the stationary periodic measure to define an indicator for the stochastic resonance.

  8. A random dynamical systems perspective on stochastic resonance

    OpenAIRE

    Cherubini, Anna Maria; Lamb, Jeroen S. W.; Rasmussen, Martin; Sato, Yuzuru

    2015-01-01

    We study stochastic resonance in an over-damped approximation of the stochastic Duffing oscillator from a random dynamical systems point of view. We analyse this problem in the general framework of random dynamical systems with a nonautonomous forcing. We prove the existence of a unique global attracting random periodic orbit and a stationary periodic measure. We use the stationary periodic measure to define an indicator for the stochastic resonance.

  9. Analytic Theory and Numerical Study of the Magnetic Field Line Random Walk in Reduced Magnetohydrodynamic Turbulence

    Science.gov (United States)

    Ruffolo, D. J.; Snodin, A. P.; Oughton, S.; Servidio, S.; Matthaeus, W. H.

    2013-12-01

    The random walk of magnetic field lines is examined analytically and numerically in the context of reduced magnetohydrodynamic (RMHD) turbulence, which provides a useful description of plasmas dominated by a strong mean field, such as in the solar corona. A nonperturbative theory of magnetic field line diffusion [1] is compared with the diffusion coefficients obtained by accurate numerical tracing of magnetic field lines for both synthetic models and direct numerical simulations of RMHD. Statistical analysis of an ensemble of trajectories confirms the applicability of the theory, which very closely matches the numerical field line diffusion coefficient as a function of distance z along the mean magnetic field for a wide range of the Kubo number R. The theory employs Corrsin's independence hypothesis, sometimes thought to be valid only at low R. However, the results demonstrate that it works well up to R=10, both for a synthetic RMHD model and an RMHD simulation. The numerical results from RMHD simulation are compared with and without phase randomization, demonstrating an effect of coherent structures on the field line random walk for low Kubo number. Partially supported by a postdoctoral fellowship from Mahidol University, the Thailand Research Fund, POR Calabria FSE-2007/2013, the US NSF (AGS-1063439 and SHINE AGS-1156094), NASA (Heliophysics Theory NNX08AI47G & NNX11AJ44G), by the Solar Probe Plus Project through the ISIS Theory team, by the MMS Theory and Modeling team, and by EU Marie Curie Project FP7 PIRSES-2010-269297 'Turboplasmas' at Università della Calabria. [1] D. Ruffolo and W. H. Matthaeus, Phys. Plasmas, 20, 012308 (2013).

  10. On potential kernels associated with random dynamical systems

    Directory of Open Access Journals (Sweden)

    Mohamed Hmissi

    2015-01-01

    In particular, we provide a constructive method for global Lyapunov functions for gradient-like random dynamical systems. This result generalizes an analogous theorem known for deterministic dynamical systems.

  11. AN INVESTIGATION OF MAGNETIC BEARING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Gürcan SAMTAŞ

    2007-02-01

    Full Text Available The magnetic bearing consists of levitating a shaft so that it is free to rotate about its axis. The magnetic bearing has the advantages of being very quiet work and very cleanliness because there is no mechanical friction or lubricants. The shaft has two permanent magnets attached to it. These two magnets determine a straight line rotation axis of the rotor shaft. The magnets are radially levitated and centered within a cavity by a passive permanent magnetic field in the adding stator housing assembly. The levitation and centering of the shaft axially is stabilized by a closed loop electronic servo circuit that regulates an electromagnetic field in the stator housing that pushes and pulls on the shaft magnets. The rotor weight can be between one gram and forty five thousand, four hundred grams. In 1985, the first magnetic bearing was developed that it had used to applications of gas turbines and other compressors. In these days, they can be used by many applications which are Medical, Transportation, Machine and Tools Industry, Aerospace, Vacuum and Clean room Environments... etc.

  12. A randomized model for communicating embedded systems

    NARCIS (Netherlands)

    Bujorianu, M.C.; Bujorianu, L.M.

    2008-01-01

    Nowadays, there is an intense research activity in designing systems that operate in real life, physical environments. This research is spanned by various areas in computer science and engineering: embedded systems, reactive systems, wireless communications, hybrid systems, stochastic processes,

  13. Final prototype of magnetically suspended flywheel energy storage system

    Science.gov (United States)

    Anand, D. K.; Kirk, J. A.; Zmood, R. B.; Pang, D.; Lashley, C.

    1991-01-01

    A prototype of a 500 Wh magnetically suspended flywheel energy storage system was designed, built, and tested. The authors present the work done and include the following: (1) a final design of the magnetic bearing, control system, and motor/generator, (2) construction of a prototype system consisting of the magnetic bearing stack, flywheel, motor, container, and display module, and (3) experimental results for the magnetic bearings, motor, and the entire system. The successful completion of the prototype system has achieved: (1) manufacture of tight tolerance bearings, (2) stability and spin above the first critical frequency, (3) use of inside sensors to eliminate runout problems, and (4) integration of the motor and magnetic bearings.

  14. Magnetic levitation system for moving objects

    Science.gov (United States)

    Post, Richard F.

    1998-01-01

    Repelling magnetic forces are produced by the interaction of a flux-concentrated magnetic field (produced by permanent magnets or electromagnets) with an inductively loaded closed electric circuit. When one such element moves with respect to the other, a current is induced in the circuit. This current then interacts back on the field to produce a repelling force. These repelling magnetic forces are applied to magnetically levitate a moving object such as a train car. The power required to levitate a train of such cars is drawn from the motional energy of the train itself, and typically represents only a percent or two of the several megawatts of power required to overcome aerodynamic drag at high speeds.

  15. Fusion magnet safety studies program: superconducting magnet protection system and failure. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Allinger, J.; Danby, G.; Hsieh, S.Y.; Keane, J.; Powell, J.; Prodell, A.

    1975-11-01

    This report includes the first two quarters study of available information on schemes for protecting superconducting magnets. These schemes can be divided into two different categories. The first category deals with the detection of faulty regions (or normal regions) in the magnet. The second category relates to the protection of the magnet when a fault is detected, and the derived signal which can be used to activate a safety system (or energy removal system). The general detection and protection methods are first described briefly and then followed by a survey of the protection systems used by different laboratories for various magnets. A survey of the cause of the magnet difficulties or failures is also included. A preliminary discussion of these protection schemes and the experimental development of this program is given.

  16. Magnetically guided micro-droplet using biological magnetic material for smart drug delivery system.

    Science.gov (United States)

    Oh, Darong; Lee, Suwon; Kim, Jinhyuk; Choi, Hongsoo; Seo, Jongmo; Koo, Kyo-in

    2014-01-01

    Biodegradable polymer droplet containing magnetosome demonstrates active propulsion by magnetic field. Magnetosome is extracted from magnetotactic bacteria, AMB-1. Mixture of magnetosome and sodium alginate composes into droplet using the microfluidic device applied Plateau-Rayleigh instability principle. The magnetosome-contained droplet selects its route at the bifurcate microchannels by magnetic field. This shows tissue targeting potential of the proposed drug delivery system.

  17. Open-ended magnetic confinement systems for fusion

    Energy Technology Data Exchange (ETDEWEB)

    Post, R.F.; Ryutov, D.D.

    1995-05-01

    Magnetic confinement systems that use externally generated magnetic fields can be divided topologically into two classes: ``closed`` and `open``. The tokamak, the stellarator, and the reversed-field-pinch approaches are representatives of the first category, while mirror-based systems and their variants are of the second category. While the recent thrust of magnetic fusion research, with its emphasis on the tokamak, has been concentrated on closed geometry, there are significant reasons for the continued pursuit of research into open-ended systems. The paper discusses these reasons, reviews the history and the present status of open-ended systems, and suggests some future directions for the research.

  18. SLC Arc transport system: AG-magnet measurement and performance

    Energy Technology Data Exchange (ETDEWEB)

    Weng, W.T.; Anderson, M.; Byers, R.; Cobb, J.; Fischer, G.; Hamilton, V.

    1985-03-01

    This paper describes the design, construction, and operation of devices used to rapidly measure the mechanical and magnetic properties of some 950 Alternate gradient magnets used in the arc system of the Stanford Linear Collider. The problems of dealing with the measurement of the transverse dimensions to within minute (0.0001 in.) resolution of objects that are 8 ft long are discussed. Early results from the production runs of these magnets are presented. 7 refs., 6 figs.

  19. Design of Magnetic Levitation System Based on Inverse Control Techniqueusing Adaptive Neuro-Fuzzy Inference System

    Directory of Open Access Journals (Sweden)

    Mithaq Nama Raheema

    2017-07-01

    Full Text Available The design of ANFIS network based inverse control technique is proposed in this paperfor this system. Simulation is implemented in MATLAB after the ANFIS is trained and it is shown that results are applicable in process industry and acceptable for reference control applications. The effectiveness of the proposed ANFIS in inverse controller it has been tested by entering random selected points which represent the values of input voltage from the system under control as a reference input to inverse modelling, after that entering the results of inverse modelling to the modelling of magnet levitation system to form the desired output. The result is acceptable with small errors about 0.0011

  20. Two simple modifications to improve the magnetic field profile in radial magnetic systems

    Science.gov (United States)

    Li, Shisong; Schlamminger, Stephan

    2017-10-01

    All present watt balances employ permanent magnet systems using a yoke with high permeability as flux return. Very often these systems are built with vertical and azimuthal symmetries. In its simplest form, the air gap is defined as the radial distance between an inner and outer yoke with the same height. This design leads to sloped field lines away from the plane of vertical symmetry. In order to suppress this vertical magnetic field, we propose two modified magnet constructions: (1) adding a permanent magnet in the outer yoke, and (2) decreasing the height of the outer yoke. Finite element method simulations show that, with reasonable optimization, either proposal can lower the vertical magnetic field by about one order of magnitude.

  1. Theory of Magnetization in Bloch Electron Systems

    Science.gov (United States)

    Ogata, Masao

    2017-04-01

    The exact formulas for magnetization and magnetic susceptibility are derived for Bloch electrons in terms of Bloch wave functions. They are extensions of the previous work to general cases where the spin-orbit interaction as well as the Zeeman term is included, the potential is noncentrosymmetric, and the time-reversal symmetry is broken. The obtained magnetization for Bloch electrons is a natural generalization of the free-electron magnetic moment including the effect of the spin-orbit interaction. The obtained susceptibility has six contributions and the physical meaning of each term is clarified. The new formula contains the Landau-Peierls, Pauli, and Van Vleck susceptibilities, the atomic diamagnetism, and contributions from the "Berry curvature". In the atomic limit, the obtained formula reduces to two contributions: the atomic diamagnetism and a generalized form of the Van Vleck susceptibility modified by the spin-orbit interaction. It is also found that, in general cases, the Pauli, Van Vleck (interband), and Berry curvature susceptibilities are closely related to common magnetization matrix elements, which is in sharp contrast to previous studies. A general form of the off-diagonal magnetic susceptibility is also derived.

  2. Parsimonious Continuous Time Random Walk Models and Kurtosis for Diffusion in Magnetic Resonance of Biological Tissue

    Directory of Open Access Journals (Sweden)

    Carson eIngo

    2015-03-01

    Full Text Available In this paper, we provide a context for the modeling approaches that have been developed to describe non-Gaussian diffusion behavior, which is ubiquitous in diffusion weighted magnetic resonance imaging of water in biological tissue. Subsequently, we focus on the formalism of the continuous time random walk theory to extract properties of subdiffusion and superdiffusionthrough novel simplifications of the Mittag-Leffler function. For the case of time-fractional subdiffusion, we compute the kurtosis for the Mittag-Leffler function, which provides both a connection and physical context to the much-used approach of diffusional kurtosis imaging. We provide Monte Carlo simulations to illustrate the concepts of anomalous diffusion as stochastic processes of the random walk. Finally, we demonstrate the clinical utility of the Mittag-Leffler function as a model to describe tissue microstructure through estimations of subdiffusion and kurtosis with diffusion MRI measurements in the brain of a chronic ischemic stroke patient.

  3. Parsimonious continuous time random walk models and kurtosis for diffusion in magnetic resonance of biological tissue.

    Science.gov (United States)

    Ingo, Carson; Sui, Yi; Chen, Yufen; Parrish, Todd B; Webb, Andrew G; Ronen, Itamar

    2015-03-01

    In this paper, we provide a context for the modeling approaches that have been developed to describe non-Gaussian diffusion behavior, which is ubiquitous in diffusion weighted magnetic resonance imaging of water in biological tissue. Subsequently, we focus on the formalism of the continuous time random walk theory to extract properties of subdiffusion and superdiffusion through novel simplifications of the Mittag-Leffler function. For the case of time-fractional subdiffusion, we compute the kurtosis for the Mittag-Leffler function, which provides both a connection and physical context to the much-used approach of diffusional kurtosis imaging. We provide Monte Carlo simulations to illustrate the concepts of anomalous diffusion as stochastic processes of the random walk. Finally, we demonstrate the clinical utility of the Mittag-Leffler function as a model to describe tissue microstructure through estimations of subdiffusion and kurtosis with diffusion MRI measurements in the brain of a chronic ischemic stroke patient.

  4. Parsimonious Continuous Time Random Walk Models and Kurtosis for Diffusion in Magnetic Resonance of Biological Tissue

    Science.gov (United States)

    Ingo, Carson; Sui, Yi; Chen, Yufen; Parrish, Todd; Webb, Andrew; Ronen, Itamar

    2015-03-01

    In this paper, we provide a context for the modeling approaches that have been developed to describe non-Gaussian diffusion behavior, which is ubiquitous in diffusion weighted magnetic resonance imaging of water in biological tissue. Subsequently, we focus on the formalism of the continuous time random walk theory to extract properties of subdiffusion and superdiffusion through novel simplifications of the Mittag-Leffler function. For the case of time-fractional subdiffusion, we compute the kurtosis for the Mittag-Leffler function, which provides both a connection and physical context to the much-used approach of diffusional kurtosis imaging. We provide Monte Carlo simulations to illustrate the concepts of anomalous diffusion as stochastic processes of the random walk. Finally, we demonstrate the clinical utility of the Mittag-Leffler function as a model to describe tissue microstructure through estimations of subdiffusion and kurtosis with diffusion MRI measurements in the brain of a chronic ischemic stroke patient.

  5. Overview of Magnetic Levitation Systems with Emphasis on Electrodynamic Suspension

    Directory of Open Access Journals (Sweden)

    Abbas Najjar-Khodabakhsh

    2011-07-01

    Full Text Available Nowadays, the use of magnetic levitation systems has made attention in transportation. Suspension is caused by two magnetic fields in the near distance and thus the repulsion and attraction induced between them. In Iran, different types of magnetic systems and their applications, especially in the transportation system were not considered deeply and the features and specifications of each of these systems is not discussed yet. In this article we want to review past research and studies on the applications and the characteristics of these systems to fully express and we do compare them with each other. We also offer the laboratory equipment for study the behavior of magnetic suspension systems with emphasis on electrodynamic suspension.

  6. Applications of Random Matrix Ensembles in Nuclear Systems

    OpenAIRE

    Duras, Maciej M.

    2003-01-01

    The random matrix ensembles (RME), especially Gaussian RME and Ginibre RME, are applied to nuclear systems, molecular systems, and two-dimensional electron systems (Wigner-Dyson electrostatic analogy). Measures of quantum chaos and quantum integrability with respect to eigenergies of quantum systems are defined and calculated.

  7. Random matrix theory for pseudo-Hermitian systems: Cyclic blocks

    Indian Academy of Sciences (India)

    We discuss the relevance of random matrix theory for pseudo-Hermitian systems, and, for Hamiltonians that break parity and time-reversal invariance . In an attempt to understand the random Ising model, we present the treatment of cyclic asymmetric matrices with blocks and show that the nearest-neighbour spacing ...

  8. Permanent magnet electron beam ion source/trap systems with bakeable magnets for improved operation conditions.

    Science.gov (United States)

    Schmidt, M; Zschornack, G; Kentsch, U; Ritter, E

    2014-02-01

    The magnetic system of a Dresden electron beam ion source (EBIS) generating the necessary magnetic field with a new type of permanent magnet made of high energy density NdFeB-type material operable at temperatures above 100 °C has been investigated and tested. The employment of such kind of magnets provides simplified operation without the time-consuming installation and de-installation procedures of the magnets for the necessary baking of the ion source after commissioning and maintenance work. Furthermore, with the use of a new magnetization technique the geometrical filling factor of the magnetic Dresden EBIS design could be increased to a filling factor of 100% leading to an axial magnetic field strength of approximately 0.5 T exceeding the old design by 20%. Simulations using the finite element method software Field Precision and their results compared with measurements are presented as well. It could be shown that several baking cycles at temperatures higher than 100 °C did not change the magnetic properties of the setup.

  9. Focus on hybrid magnetic/superconducting systems Focus on hybrid magnetic/superconducting systems

    Science.gov (United States)

    Cooley, Lance; Moshchalkov, Victor; Li, Qiang

    2011-02-01

    Like antagonistic cousins from a common heritage, the competition between superconductivity and magnetism for correlated electron states, and coexistence in some rare cases, produces a rich variety of physical behavior, useful materials, and technologically important properties. Many pages of Superconductor Science and Technology are devoted to cuprates, pnictides, and other compounds where the mechanism of superconductivity itself is intertwined with magnetism. This focus issue explores another area, in which superconductivity and magnetism are combined as a hybrid system to create new properties not possible with either system alone, or to improve upon the properties of either system in dramatic ways. In recent years, great progress has been made in this exciting, relatively new field, followed by many workshops and special sessions in major international conferences. A concise and up-to-date focus issue of Superconductor Science and Technology is timely to summarize the latest developments. We, the Guest Editors, would like to thank those colleagues who contributed their most recent and interesting findings to this focus issue: Silhanek and co-workers reported both theoretical and experimental investigations of the dynamics of vortex chains for different arrangements of magnetic moments. Their approach of time-dependent Ginzburg-Landau formalism now replaces the previously proposed empirical models to explain the most relevant properties of the dynamics of these S/F hybrid systems. Hikino and co-workers presented a new route to observe the spin-wave excitation by the Josephson effect, through a theoretical investigation of the resistively shunted junction model, extended by considering the gauge invariance including magnetization. When the magnetization is driven by the microwave adjusted to the ferromagnetic resonance frequency, the dc supercurrent is induced in the junction, and the current-voltage curve shows step structures as a function of applied voltage

  10. Magnetic microspheres as magical novel drug delivery system: A review

    Directory of Open Access Journals (Sweden)

    Satinder Kakar

    2013-01-01

    Full Text Available Magnetic microspheres hold great promise for reaching the goal of controlled and site specific drug delivery. Magnetic microspheres as an alternative to traditional radiation methods which uses highly penetrating radiations that is absorbed throughout the body. Its use is limited by toxicity and side effects. Now days, several targeted treatment systems including magnetic field, electric field, ultrasound, temperature, UV light and mechanical force are being used in many disease treatments (e.g. cancer, nerve damage, heart and artery, anti-diabetic, eye and other medical treatments. Among them, the magnetic targeted drug delivery system is one of the most attractive and promising strategy for delivering the drug to the specified site. Magnetically controlled drug targeting is one of the various possible ways of drug targeting. This technology is based on binding establish anticancer drug with ferrofluid that concentrate the drug in the area of interest (tumor site by means of magnetic fields. There has been keen interest in the development of a magnetically target drug delivery system. These drug delivery systems aim to deliver the drug at a rate directed by the needs of the body during the period of treatment, and target the activity entity to the site of action. Magnetic microspheres were developed to overcome two major problems encountered in drug targeting namely: RES clearance and target site specificity.

  11. Interplay of magnetism and valence instabilities in lanthanide systems

    Directory of Open Access Journals (Sweden)

    José Luiz Ferreira

    2016-06-01

    Full Text Available The valence instability in lanthanide systems is described within an extended periodic Anderson Hamiltonian (EPAM which includes Coulomb repulsion between f- and conduction- electrons, allowing to describe both discontinuous and continuous valence variations. We investigate the connection between valence and magnetism in this model and show that it can be applied to several lanthanide compounds showing both magnetic and valence instabilities.

  12. Magnetization Plateaus and Thermal Entanglement of Spin Systems

    Science.gov (United States)

    Ananikian, N.; Burdík, Č.; Ananikyan, L.; Poghosyan, H.

    2017-01-01

    The geometrically magnetic frustrations and quantum thermal entanglement of antiferromagnetic metal-containing compounds are considered on a diamond chain. We researched the magnetic and thermal properties of the symmetric Hubbard dimers with delocalized interstitial spins and the quantum entanglement states. It is presented magnetization plateaus and negativity in spin-1 Ising-Heisenberg model using transfer matrix technique. Applying the dynamic system approach we study the magnetic curves, Lyapunov exponents and superstable point in the two-dimensional mapping for the partition function of spin-1 classical and Ising-Heisenberg models at T → 0 on a diamond chain.

  13. Self-assembly in the systems of magnetic anisotropic nanoparticles

    Science.gov (United States)

    Gudkova, A. V.; Pyanzina, E. S.

    2017-11-01

    This paper presents the complex investigation of the system of magnetic anisotropic nanoparticles using computer simulations in a wide range of the system's parameters. The cluster analysis was made, various average characteristics of the formed clusters were calculated and the initial magnetic susceptibility and the radial distribution function were computed. It was shown that via changing the nanoparticles characteristics (their shape and the values of the magnetic moments) it's possible to change macroscopic response of the system, that implements the idea of tuning and design new materials with controllable properties.

  14. Magnetic Measurement Systems for the LHC Dipole Assembly Companies

    CERN Document Server

    Billan, J; Giloteaux, D; Raimondo, A; Remondino, Vittorio; Reymond, H; Rijllart, A

    2004-01-01

    The LHC superconducting lattice dipole magnets are presently under construction in three European industries. Due to the stringent magnet performance required for the LHC, these magnets have to be built with high accuracy during all the steps of their assembly. In order to detect defects in the earliest industrial production phases and to ensure the quality of the magnetic field as specified by the CERN contracts, dedicated measurement benches have been built and installed in each assembly company to validate the magnetic field quality at two important production stages: the collared coils and the final cold mass. This paper describes the initial requirements and the implementation of the magnetic measurement systems. Details on the technical solutions, the present status and measurement results are presented.

  15. A portable, low-cost, 3D-printed main magnetic field system for magnetic imaging.

    Science.gov (United States)

    Iksung Kang

    2017-07-01

    In this paper, a portable, low-cost, 3D-printed system for main magnetic field is proposed to suggest a solution for accessibility problems of current magnetic imaging systems, e.g. MRI scanner, their size and cost. The system consists of twelve pairs of NdFeB N35 permanent magnets arranged in a Halbach array in a 3D-printed, cylindrical container based on FEM simulation results by COMSOL Multiphysics 4.4b. Its magnetic field homogeneity and field strength were measured by Hall sensors, WSH-135 XPAN2 by Wilson Semiconductor, and the container was printed by 3DISON H700 by Rokit. The system generated a 5-mm imaging quality FOV and main magnetic field of 120 mT with a 12 % error in the field strength. Also, a hundred dollar was enough for the manufacture of the system with a radius of 6 cm and height of 10 cm. Given the results, I believe the system will be useful for some magnetic imaging applications, e.g. EPRI and low-field MRI.

  16. Failure modes and effects analysis of fusion magnet systems

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, M; Kazimi, M S; Siu, N O; Thome, R J

    1988-12-01

    A failure modes and consequence analysis of fusion magnet system is an important contributor towards enhancing the design by improving the reliability and reducing the risk associated with the operation of magnet systems. In the first part of this study, a failure mode analysis of a superconducting magnet system is performed. Building on the functional breakdown and the fault tree analysis of the Toroidal Field (TF) coils of the Next European Torus (NET), several subsystem levels are added and an overview of potential sources of failures in a magnet system is provided. The failure analysis is extended to the Poloidal Field (PF) magnet system. Furthermore, an extensive analysis of interactions within the fusion device caused by the operation of the PF magnets is presented in the form of an Interaction Matrix. A number of these interactions may have significant consequences for the TF magnet system particularly interactions triggered by electrical failures in the PF magnet system. In the second part of this study, two basic categories of electrical failures in the PF magnet system are examined: short circuits between the terminals of external PF coils, and faults with a constant voltage applied at external PF coil terminals. An electromagnetic model of the Compact Ignition Tokamak (CIT) is used to examine the mechanical load conditions for the PF and the TF coils resulting from these fault scenarios. It is found that shorts do not pose large threats to the PF coils. Also, the type of plasma disruption has little impact on the net forces on the PF and the TF coils. 39 refs., 30 figs., 12 tabs.

  17. Multipole Analysis of Circular Cylindircal Magnetic Systems

    Energy Technology Data Exchange (ETDEWEB)

    Selvaggi, Jerry P. [Rensselaer Polytechnic Inst., Troy, NY (United States)

    2005-12-01

    This thesis deals with an alternate method for computing the external magnetic field from a circular cylindrical magnetic source. The primary objective is to characterize the magnetic source in terms of its equivalent multipole distribution. This multipole distribution must be valid at points close to the cylindrical source and a spherical multipole expansion is ill-equipped to handle this problem; therefore a new method must be introduced. This method, based upon the free-space Green's function in cylindrical coordinates, is developed as an alternative to the more familiar spherical harmonic expansion. A family of special functions, called the toroidal functions or Q-functions, are found to exhibit the necessary properties for analyzing circular cylindrical geometries. In particular, the toroidal function of zeroth order, which comes from the integral formulation of the free-space Green's function in cylindrical coordinates, is employed to handle magnetic sources which exhibit circular cylindrical symmetry. The toroidal functions, also called Q-functions, are the weighting coefficients in a ''Fourier series-like'' expansion which represents the free-space Green's function. It is also called a toroidal expansion. This expansion can be directly employed in electrostatic, magnetostatic, and electrodynamic problems which exhibit cylindrical symmetry. Also, it is shown that they can be used as an alternative to the Elliptic integral formulation. In fact, anywhere that an Elliptic integral appears, one can replace it with its corresponding Q-function representation. A number of problems, using the toroidal expansion formulation, are analyzed and compared to existing known methods in order to validate the results. Also, the equivalent multipole distribution is found for most of the solved problems along with its corresponding physical interpretation. The main application is to characterize the external magnetic field due to a six

  18. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  19. Bionanocomposites containing magnetic graphite as potential systems for drug delivery.

    Science.gov (United States)

    Ribeiro, Lígia N M; Alcântara, Ana C S; Darder, Margarita; Aranda, Pilar; Herrmann, Paulo S P; Araújo-Moreira, Fernando M; García-Hernández, Mar; Ruiz-Hitzky, Eduardo

    2014-12-30

    New magnetic bio-hybrid matrices for potential application in drug delivery are developed from the assembly of the biopolymer alginate and magnetic graphite nanoparticles. Ibuprofen (IBU) intercalated in a Mg-Al layered double hydroxide (LDH) was chosen as a model drug delivery system (DDS) to be incorporated as third component of the magnetic bionanocomposite DDS. For comparative purposes DDS based on the incorporation of pure IBU in the magnetic bio-hybrid matrices were also studied. All the resulting magnetic bionanocomposites were processed as beads and films and characterized by different techniques with the aim to elucidate the role of the magnetic graphite on the systems, as well as that of the inorganic brucite-like layers in the drug-loaded LDH. In this way, the influence of both inorganic components on the mechanical properties, the water uptake ability, and the kinetics of the drug release from these magnetic systems were determined. In addition, the possibility of modulating the levels of IBU release by stimulating the bionanocomposites with an external magnetic field was also evaluated in in vitro assays. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Augmented reality system for freehand guide of magnetic endovascular devices.

    Science.gov (United States)

    Parrini, S; Cutolo, F; Freschi, C; Ferrari, M; Ferrari, V

    2014-01-01

    Magnetic guide of endovascular devices or magnetized therapeutic microparticles to the specific target in the arterial tree is increasingly studied, since it could improve treatment efficacy and reduce side effects. Most proposed systems use external permanent magnets attached to robotic manipulators or magnetic resonance imaging (MRI) systems to guide internal carriers to the region of treatment. We aim to simplify this type of procedures, avoiding or reducing the need of robotic arms and MRI systems in the surgical scenario. On account of this we investigated the use of a wearable stereoscopic video see-through augmented reality system to show the hidden vessel to the surgeon; in this way, the surgeon is able to freely move the external magnet, following the showed path, to lead the endovascular magnetic device towards the desired position. In this preliminary study, we investigated the feasibility of such an approach trying to guide a magnetic capsule inside a vascular mannequin. The high rate of success and the positive evaluation provided by the operators represent a good starting point for further developments of the system.

  1. TWO DIMENTIONAL STATIC MAGNETIC ANALYSIS OF RADIAL MAGNETIC BEARING SYSTEMS WITH DIFFERENT STRUCTURES

    Directory of Open Access Journals (Sweden)

    Yusuf ÖNER

    2005-03-01

    Full Text Available The friction loss of electrical machines is an important problem as like in other rotary machines. In addition, the bearings, where the friction losses occur, also require lubrication at periodic intervals and need to be maintained. In this study, to minimize the friction loss of electrical motor, two dimentional static magnetic analysis of radial magnetic bearing systems with different structures are performed and compared with each other; also, magnetic bearing system with four-pole is realized and applied to an induction motor. In simulation, the forces applied to the rotor of induction motor from designed magnetic bearing system are calculated in a computer by using FEMM software package. In application, when comparing designed magnetic bearing system with mechanical bearings up to the revolution of 350 rpm, it was observed that the loss of no-load operating condition of induction motor is decreased about 15 % with magnetic bearing system. In addition to this, mechanical noisy of the motor is also decreased considerably.

  2. Signal processing in a randomly time varying system.

    Science.gov (United States)

    Adomian, G.

    1972-01-01

    Stochastic operators are applied to an analysis of some deterministic systems of signal transformation. The distribution of a random process at the output of a system is given through its distribution at the input and through a stochastic Green's function. A two-point correlation function is derived to obtain a solution to differential equations which contain coefficients, boundary conditions, or right-hand terms representing random processes.

  3. Randomized Algorithms for Systems and Control: Theory and Applications

    Science.gov (United States)

    2008-05-01

    IEIIT-CNR Randomized Algorithms for Systems and Control: Theory and Applications NATO LS Glasgow, Pamplona , Cleveland @RT 2008 Roberto Tempo IEIIT...Glasgow, Pamplona , Cleveland @RT 2008 roberto.tempo@polito.it IEIIT-CNR References R. Tempo, G. Calafiore and F. Dabbene, “Randomized Algorithms for...Analysis and Control of Uncertain Systems,” Springer-Verlag, London, 2005 R Tempo and H Ishii “Monte Carlo and Las Vegas NATO LS Glasgow, Pamplona , Cleveland

  4. Magnetic field effects in electron systems with imperfect nesting

    Science.gov (United States)

    Sboychakov, A. O.; Rakhmanov, A. L.; Kugel, K. I.; Rozhkov, A. V.; Nori, Franco

    2017-01-01

    We analyze the effects of an applied magnetic field on the phase diagram of a weakly correlated electron system with imperfect nesting. The Hamiltonian under study describes two bands: electron and hole ones. Both bands have spherical Fermi surfaces, whose radii are slightly mismatched due to doping. These types of models are often used in the analysis of magnetic states in chromium and its alloys, superconducting iron pnictides, AA-type bilayer graphene, borides, etc. At zero magnetic field, the uniform ground state of the system turns out to be unstable against electronic phase separation. The applied magnetic field affects the phase diagram in several ways. In particular, the Zeeman term stabilizes new antiferromagnetic phases. It also significantly shifts the boundaries of inhomogeneous (phase-separated) states. At sufficiently high fields, the Landau quantization gives rise to oscillations of the order parameters and of the Néel temperature as a function of the magnetic field.

  5. The LHC magnet system and its status of development

    Science.gov (United States)

    Bona, Maurizio; Perin, Romeo; Vlogaert, Jos

    1995-01-01

    CERN is preparing for the construction of a new high energy accelerator/collider, the Large Hadron Collider (LHC). This new facility will mainly consist of two superconducting magnetic beam channels, 27 km long, to be installed in the existing LEP tunnel. The magnetic system comprises about 1200 twin-aperture dipoles, 13.145 m long, with an operational field of 8.65 T, about 600 quadrupoles, 3 m long, and a very large number of other superconducting magnetic components. A general description of the system is given together with the main features of the design of the regular lattice magnets. The paper also describes the present state of the magnet R & D program. Results from short model work, as well as from full scale prototypes will be presented, including the recently tested 10 m long full-scale prototype dipole manufactured in industry.

  6. Interaction effects in magnetic oxide nanoparticle systems

    Indian Academy of Sciences (India)

    Hysteresis measurements performed on the thin films coated on silicon do not give evidence of the superparamagnetic transition up to room temperature and the .... for the different pyrrole concentrations and a very slight decrease in the saturation magnetization is seen with increasing monomer concentrations, which is.

  7. Magnetoresistance in magnetic domain wall systems

    NARCIS (Netherlands)

    Jonkers, PAE

    The contribution to the magneto resistance (MR) was calculated for a single magnetic domain wall present in a small 2D impure ferromagnetic wire. On assuming low-temperatures and spin-independent impurity scattering the mechanism responsible for a positive contribution to MR is quantum interference.

  8. Open quantum systems and random matrix theory

    Energy Technology Data Exchange (ETDEWEB)

    Mulhall, Declan [Department of Physics/Engineering, University of Scranton, Scranton, Pennsylvania 18510-4642 (United States)

    2014-10-15

    A simple model for open quantum systems is analyzed with RMT. The system is coupled to the continuum in a minimal way. In this paper we see the effect of opening the system on the level statistics, in particular the level spacing, width distribution and Δ{sub 3}(L) statistic are examined as a function of the strength of this coupling. The usual super-radiant state is observed, and it is seen that as it is formed, the level spacing and Δ{sub 3}(L) statistic exhibit the signatures of missed levels.

  9. Two connections between random systems and non-Gibbsian measures

    NARCIS (Netherlands)

    van Enter, A.C.D.; Kulske, C.

    2007-01-01

    In this contribution we discuss the role disordered (or random) systems have played in the study of non-Gibbsian measures. This role has two main aspects, the distinction between which has not always been fully clear: 1) From disordered systems: Disordered systems can be used as a tool; analogies

  10. Reliability Analysis of Random Vibration Transmission Path Systems

    Directory of Open Access Journals (Sweden)

    Wei Zhao

    2017-01-01

    Full Text Available The vibration transmission path systems are generally composed of the vibration source, the vibration transfer path, and the vibration receiving structure. The transfer path is the medium of the vibration transmission. Moreover, the randomness of transfer path influences the transfer reliability greatly. In this paper, based on the matrix calculus, the generalized second moment technique, and the stochastic finite element theory, the effective approach for the transfer reliability of vibration transfer path systems was provided. The transfer reliability of vibration transfer path system with uncertain path parameters including path mass and path stiffness was analyzed theoretically and computed numerically, and the correlated mathematical expressions were derived. Thus, it provides the theoretical foundation for the dynamic design of vibration systems in practical project, so that most random path parameters can be considered to solve the random problems for vibration transfer path systems, which can avoid the system resonance failure.

  11. Stability of magnetic tip/superconductor levitation systems

    Science.gov (United States)

    K. Alqadi, M.

    2015-11-01

    The vertical stability of a magnetic tip over a superconducting material is investigated by using the critical state and the frozen image models. The analytical expressions of the stiffness and the vibration frequency about the equilibrium position are derived in term of the geometrical parameters of the magnet/superconductor system. It is found that the stability of the system depends on the shape of the superconductor as well as its thickness.

  12. A magnetic suspension system for measuring liquid density

    Directory of Open Access Journals (Sweden)

    Luz María Centeno González

    2013-04-01

    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  13. Active magnetic bearing system based on sliding mode control

    Science.gov (United States)

    Zhang, Yanhong

    2017-07-01

    A new sliding mode variable structure control algorithm suitable for active magnetic bearing is proposed, which is widely used for nonlinear control system. The model and controller is designed, simulation and experimental parts are also made, according to the switching function and the sliding mode control law. The current of electromagnet is adjusted to realize stable levitation of the rotor. The experimental result shows that the sliding mode variable structure controller is an effective way for magnetic bearing control, and the active magnetic bearing system is a highly nonlinear and advanced control method that can reduce the setting time and the cost.

  14. Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory

    Directory of Open Access Journals (Sweden)

    Austin Deschenes

    2016-11-01

    Full Text Available Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM. Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. In this work we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We compare self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. The highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ, most of the heat is dissipated on the lower potential side of the magnetic junction. This asymmetry in heating, which has also been observed experimentally, is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.

  15. A type of 2D magnetic equivalent circuit framework of permanent magnet for magnetic system in AEMR

    Directory of Open Access Journals (Sweden)

    Huimin Liang

    2015-02-01

    Full Text Available Modeling of permanent magnet (PM is very important in the process of electromagnetic system calculation of aerospace electromagnetic relay (AEMR. In traditional analytical calculation, PM is often equivalent to a lumped parameter model of one magnetic resistance and one magnetic potential, but great error is often caused for the inner differences of PM; based on the conception of flux tube, a type of 2D magnetic equivalent circuit framework of permanent magnet model (2D MECF is established; the element is defined, the relationship between elements is deduced, and solution procedure as well as verification condition of this model is given; by a case study of the electromagnetic system of a certain type of AEMR, the electromagnetic system calculation model is established based on 2D MECF and the attractive force at different rotation angles is calculated; the proposed method is compared with the traditional lumped parameter model and finite element method (FEM; for some types of electromagnetic systems with symmetrical structure, 2D MECF proves to be of acceptable accuracy and high calculation speed which fit the requirement of robust design for AEMR.

  16. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  17. Preoperative Magnetic Resonance Imaging in Patients With Stage I Invasive Ductal Breast Cancer: A Prospective Randomized Study.

    Science.gov (United States)

    Brück, N; Koskivuo, I; Boström, P; Saunavaara, J; Aaltonen, R; Parkkola, R

    2018-03-01

    Preoperative magnetic resonance imaging has become an important complementary imaging technique in patients with breast cancer, providing additional information for preoperative local staging. Magnetic resonance imaging is recommended selectively in lobular breast cancer and in patients with dense breast tissue in the case when mammography and ultrasound fail to fully evaluate the lesion, but the routine use of magnetic resonance imaging in all patients with invasive ductal carcinoma is controversial. The purpose of this randomized study was to investigate the diagnostic value of preoperative magnetic resonance imaging and its impact on short-term surgical outcome in newly diagnosed unifocal stage I invasive ductal carcinoma. A total of 100 patients were randomized to either receive preoperative breast magnetic resonance imaging or to be scheduled directly to operation without magnetic resonance imaging on a 1:1 basis. There were 50 patients in both study arms. In 14 patients (28%), breast magnetic resonance imaging detected an additional finding and seven of them were found to be malignant. Six additional cancer foci were found in the ipsilateral breast and one in the contralateral breast. Magnetic resonance imaging findings caused a change in planned surgical management in 10 patients (20%). Mastectomy was performed in six patients (12%) in the magnetic resonance imaging group and in two patients (4%) in the control group ( p = 0.140). The breast reoperation rate was 14% in the magnetic resonance imaging group and 24% in the control group ( p = 0.202). The mean interval between referral and first surgical procedure was 34 days in the magnetic resonance imaging group and 21 days in the control group ( p magnetic resonance imaging may be beneficial for some patients with early-stage invasive ductal carcinoma, but its routine use is not recommended without specific indications.

  18. Indoor Positioning System Using Magnetic Field Map Navigation and an Encoder System.

    Science.gov (United States)

    Kim, Han-Sol; Seo, Woojin; Baek, Kwang-Ryul

    2017-03-22

    In the indoor environment, variation of the magnetic field is caused by building structures, and magnetic field map navigation is based on this feature. In order to estimate position using this navigation, a three-axis magnetic field must be measured at every point to build a magnetic field map. After the magnetic field map is obtained, the position of the mobile robot can be estimated with a likelihood function whereby the measured magnetic field data and the magnetic field map are used. However, if only magnetic field map navigation is used, the estimated position can have large errors. In order to improve performance, we propose a particle filter system that integrates magnetic field map navigation and an encoder system. In this paper, multiple magnetic sensors and three magnetic field maps (a horizontal intensity map, a vertical intensity map, and a direction information map) are used to update the weights of particles. As a result, the proposed system estimates the position and orientation of a mobile robot more accurately than previous systems. Also, when the number of magnetic sensors increases, this paper shows that system performance improves. Finally, experiment results are shown from the proposed system that was implemented and evaluated.

  19. Magnetic stability in exchange-spring and exchange bias systems after multiple switching cycles.

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, J. S.; Inomata, A.; You, C.-Y.; Pearson, J. E.; Bader, S. D.

    2001-06-01

    We have studied the magnetic stability in exchange bias and exchange spring systems prepared via epitaxial sputter deposition. The two interfacial exchange coupled systems, Fe/Cr(211) double superlattices consisting of a ferromagnetic and an antiferromagnetic Fe/Cr superlattice that are exchange coupled through a Cr spacer, and Sin-Co/Fe exchange-spring bilayer structures with ferromagnetically coupled hard Sin-Co layer and soft Fe layer, were epitaxially grown on suitably prepared Cr buffer layers to give rise to different microstructure and magnetic anisotropy. The magnetic stability was investigated using the magneto-optic Kerr effect during repeated reversal of the soft layer magnetization by field cycling up to 10{sup 7} times. For uniaxial Fe/Cr exchange biased double superlattices and exchange spring bilayers with uniaxial Sin-Co, small but rapid initial decay in the exchange bias field HE and in the remanent magnetization is observed. However, the exchange spring bilayers with biaxial and random in-plane anisotropy in the Sin-Co layer shows gradual decay in H{sub E} and without large reduction of the magnetization. The different decay behaviors are attributed to the different microstructure and spin configuration of the pinning layers.

  20. ATLAS magnet common cryogenic, vacuum, electrical and control systems

    CERN Document Server

    Miele, P; Delruelle, N; Geich-Gimbel, C; Haug, F; Olesen, G; Pengo, R; Sbrissa, E; Tyrvainen, H; ten Kate, H H J

    2004-01-01

    The superconducting Magnet System for the ATLAS detector at the LHC at CERN comprises a Barrel Toroid, two End Cap Toroids and a Central Solenoid with overall dimensions of 20 m diameter by 26 m length and a stored energy of 1.6 GJ. Common proximity cryogenic and electrical systems for the toroids are implemented. The Cryogenic System provides the cooling power for the 3 toroid magnets considered as a single cold mass (600 tons) and for the CS. The 21 kA toroid and the 8 kA solenoid electrical circuits comprise both a switch-mode power supply, two circuit breakers, water cooled bus bars, He cooled current leads and the diode resistor ramp-down unit. The Vacuum System consists of a group of primary rotary pumps and sets of high vacuum diffusion pumps connected to each individual cryostat. The Magnet Safety System guarantees the magnet protection and human safety through slow and fast dump treatment. The Magnet Control System ensures control, regulation and monitoring of the operation of the magnets. The update...

  1. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  2. Magnetic field lines, Hamiltonian dynamics, and nontwist systems

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, P. J. [Department of Physics and Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States)

    2000-06-01

    Magnetic field lines typically do not behave as described in the symmetrical situations treated in conventional physics textbooks. Instead, they behave in a chaotic manner; in fact, magnetic field lines are trajectories of Hamiltonian systems. Consequently the quest for fusion energy has interwoven, for 50 years, the study of magnetic field configurations and Hamiltonian systems theory. The manner in which invariant tori breakup in symplectic twist maps, maps that embody one and a half degree-of-freedom Hamiltonian systems in general and describe magnetic field lines in tokamaks in particular, will be reviewed, including symmetry methods for finding periodic orbits and Greene's residue criterion. In nontwist maps, which describe, e.g., reverse shear tokamaks and zonal flows in geophysical fluid dynamics, a new theory is required for describing tori breakup. The new theory is discussed and comments about renormalization are made. (c) 2000 American Institute of Physics.

  3. Probing Gravitational Sensitivity in Biological Systems Using Magnetic Body Forces

    Science.gov (United States)

    Guevorkian, Karine; Wurzel, Sam; Mihalusova, Mariana; Valles, Jim

    2003-01-01

    At Brown University, we are developing the use of magnetic body forces as a means to simulate variable gravity body forces on biological systems. This tool promises new means to probe gravi-sensing and the gravi-response of biological systems. It also has the potential as a technique for screening future systems for space flight experiments.

  4. Network Randomization and Dynamic Defense for Critical Infrastructure Systems

    Energy Technology Data Exchange (ETDEWEB)

    Chavez, Adrian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Martin, Mitchell Tyler [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hamlet, Jason [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stout, William M.S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lee, Erik [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    Critical Infrastructure control systems continue to foster predictable communication paths, static configurations, and unpatched systems that allow easy access to our nation's most critical assets. This makes them attractive targets for cyber intrusion. We seek to address these attack vectors by automatically randomizing network settings, randomizing applications on the end devices themselves, and dynamically defending these systems against active attacks. Applying these protective measures will convert control systems into moving targets that proactively defend themselves against attack. Sandia National Laboratories has led this effort by gathering operational and technical requirements from Tennessee Valley Authority (TVA) and performing research and development to create a proof-of-concept solution. Our proof-of-concept has been tested in a laboratory environment with over 300 nodes. The vision of this project is to enhance control system security by converting existing control systems into moving targets and building these security measures into future systems while meeting the unique constraints that control systems face.

  5. Force Measurements in Magnetic Suspension and Balance System

    Science.gov (United States)

    Kuzin, Alexander; Shapovalov, George; Prohorov, Nikolay

    1996-01-01

    The description of an infrared telemetry system for measurement of drag forces in Magnetic Suspension and Balance Systems (MSBS) is presented. This system includes a drag force sensor, electronic pack and transmitter placed in the model which is of special construction, and receiver with a microprocessor-based measuring device, placed outside of the test section. Piezosensitive resonators as sensitive elements and non-magnetic steel as the material for the force sensor are used. The main features of the proposed system for load measurements are discussed and the main characteristics are presented.

  6. Fundamental study on the magnetic field control method using multiple HTS coils for Magnetic Drug Delivery System

    Science.gov (United States)

    Hirano, R.; Kim, S. B.; Nakagawa, T.; Tomisaka, Y.; Ueda, H.

    2017-07-01

    The magnetic drug delivery system (MDDS) is a key technology to reduce the side effects in the medical applications, and the magnetic force control is very important issue in MDDS. In this application, the strength of magnetic field and gradient required to MDDS devices are 54 mT and 5.5 T/m, respectively. We proposed the new magnetic force control system that consists of the multiple racetrack HTS magnets. We can control the magnetic field gradient along the longitudinal direction by the arrangement of the multiple racetrack HTS magnets and operating current of each magnet. When the racetrack HTS magnets were used, the critical current was reduced by the self-magnetic field. Therefore, the shape design of HTS magnet to reduce the magnet field into the surface of HTS tapes was required. Therefore, the electromagnetic analysis based on finite element method (FEM) was carried out to design and optimize the shape of multiple racetrack HTS magnet. We were able to suppress the reduction of critical current by placing the magnetic substance at upper and lower side of the HTS magnets. It was confirmed that obtained maximum values of magnetic field strength and field gradient were 33 mT and 0.18 T/m, respectively.

  7. The superconducting magnet system for the ATLAS Detector at CERN

    CERN Document Server

    ten Kate, H H J

    2000-01-01

    The superconducting magnet system for the ATLAS Detector for the Large Hadron Collider at CERN is under construction since 1997. The magnet system is a hybrid of 4 superconducting magnets, a 2.5 m bore, 5.3 m long 2 T central solenoid servicing the inner detector and three 4 T toroids with global dimensions of 20 m diameter, 25 m long providing the magnetic field of about 1 T for the muon detectors. The operating currents of the solenoid and toroids are 8 and 20 kA respectively with a total stored energy of 1.6 GJ. The realization of the system is challenging due to its unusual size and complexity. Last year the construction of the coils and cryostats commenced in industry. The manufacture of the solenoid cold mass is already finished and the delivery of the individual toroid coils will commence in 2001. An on-surface test of all magnets will occur. After installation in a new cavern 100 m underground this will start in 2003 leading to commissioning of the entire magnet system in early 2005. In the paper vari...

  8. Experimental Study on Position Control System Using Encoderless Magnetic Motion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Youn; Heo, Hoon [Korea Univ., Seoul (Korea, Republic of); Yun, Young Min; Shim, Ho Keun; Kwon, Young Mok [TPC Mechatronics, Daejeon (Korea, Republic of)

    2016-01-15

    A position control system composed of the PMLSM(Permanent Magnet Linear Synchronous Motor), unlike conventional linear permanent magnet synchronous motor is fixed to the permanent magnet moving coil rails (permanent magnet = stator, coil = mover), the coil is fixed, moving the permanent magnet, we propose a position control system (permanent magnet = mover, coil = stator) structure. Position is measured not using conventional encoder or resolver but by adopting vector control method using 2 hall sensors generating rectangular signal. This method estimate the velocity and position of mover by using the quadruple of two hall sensor signal instead of encoder signal. Vector control of PMLSM using 2 hall sensor generating rectangular wave is proved to control the system stable and efficiently through simulation. Also hardware experiment reveals that the position control performance is measured within the range of 30-50μ in the accuracy of 10-20μ, which is improved twice to the conventional method. The proposed method exhibits its economical efficiency and practical usefulness. The vector control technique using two hall sensors can be installed in narrow place, accordingly it can be implemented on the system where the conventional encoder or resolver cannot operate.

  9. A motionless actuation system for magnetic shape memory devices

    Science.gov (United States)

    Armstrong, Andrew; Finn, Kevin; Hobza, Anthony; Lindquist, Paul; Rafla, Nader; Müllner, Peter

    2017-10-01

    Ni-Mn-Ga is a Magnetic Shape Memory (MSM) alloy that changes shape in response to a variable magnetic field. We can intentionally manipulate the shape of the material to function as an actuator, and the material can thus replace complicated small electromechanical systems. In previous work, a very simple and precise solid-state micropump was developed, but a mechanical rotation was required to translate the position of the magnetic field. This mechanical rotation defeats the purpose of the motionless solid-state device. Here we present a solid-state electromagnetic driver to linearly progress the position of the applied magnetic field and the associated shrinkage. The generated magnetic field was focused at either of two pole pieces, providing a mechanism for moving the localized shrinkage in the MSM element. We confirmed that our driver has sufficient strength to actuate the MSM element using optical microscopy. We validated the whole design by comparing results obtained with finite element analysis with the experimentally measured flux density. This drive system serves as a possible replacement to the mechanical rotation of the magnetic field by using a multi-pole electromagnet that sweeps the magnetic field across the MSM micropump element, solid-state switching the current to each pole piece in the multi-pole electromagnet.

  10. Superconducting magnet system(relating to accelerator); Chodendo magunetto shisutemu (kasokuki kanren)

    Energy Technology Data Exchange (ETDEWEB)

    Ouchi, Norihito [National Laboratory for High Energy Physis, Tsukuba (Japan)

    1999-09-25

    Presentations relating to superconducting magnet system are outlined, which include the studies on C-type magnet which is used for experiments of nuclear physics at Michigan Univ., on superconducting magnet system cooled by conduction used to grow crystals in strong magnetic field at Victoria Univ., on superconducting bent solenoid system of LBNL, on magnet system relating to accelerator and on transient phenomina of superconducting magnet. There were small audience at this session, and half of the programmed presentations were cancelled. (NEDO)

  11. Magnetic resonance therapy for knee osteoarthritis: a randomized, double blind placebo controlled trial.

    Science.gov (United States)

    Gökşen, Nurgül; Çaliş, Mustafa; Doğan, Serap; Çaliş, Havva T; Özgöçmen, Salih

    2016-08-01

    Therapeutic nuclear magnetic resonance therapy (MRT) works based on the electromagnetic fields. To investigate efficacy of MRT in knee osteoarthritis (OA). Prospective, randomized, double-blind, placebo controlled trial. Outpatient clinic, university hospital. Patients who had mild to moderate knee OA at a single knee joint and between 30-75-years-old were randomized by blinded chip cards (1:1). The treatment group received ten sessions of one hour daily MRT, controls received placebo MRT. All patients underwent clinical examination at baseline, after 2 weeks, and 12 weeks. Imaging included blindly assessed ultrasonography and magnetic resonance (MR) of the knee. Ninety-seven patients completed the study. Both groups improved significantly but the average change from baseline in outcome parameters was similar in MRT group (on VAS-pain,-2.6; WOMAC-pain, -2.09; WOMAC-stiffness, -1.81; WOMAC-physical, -1.96) compared to placebo after two weeks (VAS-pain,-1.6; WOMAC-pain, -1.91; WOMAC-stiffness, -1.27; WOMAC-physical, -1.54). Also changes were quite similar at the 12th week after the treatment. SF-36 components at 12th week improved but changes were not significant. Imaging arm also failed to show significant differences between groups in terms of cartilage thickness on US and MR scores. No adverse events were recorded. MRT is safe, but not superior to placebo in terms of improvement in clinical or imaging parameters after a 10-day course of treatment in mild to moderate knee OA. The present study does not promote use of a 10-day course of MRT in mild to moderate knee OA.

  12. Analysis of entropy extraction efficiencies in random number generation systems

    Science.gov (United States)

    Wang, Chao; Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Han, Zheng-Fu

    2016-05-01

    Random numbers (RNs) have applications in many areas: lottery games, gambling, computer simulation, and, most importantly, cryptography [N. Gisin et al., Rev. Mod. Phys. 74 (2002) 145]. In cryptography theory, the theoretical security of the system calls for high quality RNs. Therefore, developing methods for producing unpredictable RNs with adequate speed is an attractive topic. Early on, despite the lack of theoretical support, pseudo RNs generated by algorithmic methods performed well and satisfied reasonable statistical requirements. However, as implemented, those pseudorandom sequences were completely determined by mathematical formulas and initial seeds, which cannot introduce extra entropy or information. In these cases, “random” bits are generated that are not at all random. Physical random number generators (RNGs), which, in contrast to algorithmic methods, are based on unpredictable physical random phenomena, have attracted considerable research interest. However, the way that we extract random bits from those physical entropy sources has a large influence on the efficiency and performance of the system. In this manuscript, we will review and discuss several randomness extraction schemes that are based on radiation or photon arrival times. We analyze the robustness, post-processing requirements and, in particular, the extraction efficiency of those methods to aid in the construction of efficient, compact and robust physical RNG systems.

  13. Random Noise Monopulse Radar System for Covert Tracking of Targets

    Science.gov (United States)

    Narayanan, Ram M.

    2002-07-01

    The University of Nebraska is currently developing a unique monopulse radar concept based on the use of random noise signal for covert tracking applications. This project is funded by the Missile Defense Agency (MDA). The advantage of this system over conventional frequency-modulated continuous wave (FMCW) or short pulse systems is its covertness resulting from the random waveform's immunity from interception and jamming. The system integrates a novel heterodyne correlation receiver with conventional monopulse architecture. Based on the previous work such as random noise interferometry, a series of theoretical analysis and simulations were conducted to examine the potential performance of this monopulse system. Furthermore, a prototype system is under development to exploit practical design aspects of phase comparison angle measurement. It is revealed that random noise monopulse radar can provide the same function as traditional monopulse radar, i.e., implement range and angular estimation and tracking in real time. The bandwidth of random noise signal can be optimized to achieve the best range resolution as well as the angular accuracy.

  14. Complex Magnetic Systems Studied with Neutron Scattering

    DEFF Research Database (Denmark)

    Jacobsen, Henrik

    the spins in the nanoparticle move coherently. One part of the thesis explores the structure and dynamic of magnetic nanoparticles, with emphasis being placed on hematite. Hematite has easy-axis and in-plane anisotropy, as well as being strongly antiferromagnetic. The excitation energies have been derived...... of the lack of conventional long range order in GGG. Several members of the La2􀀀xSrxCuO4+y cuprate family of high-temperature superconductors were investigated using neutron scattering. In La2􀀀xSrxCuO4 with x = 0:12 the correlations along the c-axis were investigated. It was found...

  15. MAX-IV lattice, dynamic properties and magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Tarawneh, H. E-mail: hamed.tarawneh@maxlab.lu.se; Eriksson, M.; Lindgren, L-J.; Anderberg, B

    2003-08-11

    At MAX-LAB the next synchrotron light source MAX-IV is currently studied (Proceedings of the seventh European Particle Accelerator Conference, EPAC 02, Paris, France, 2002). In this paper, we present a possible lattice with horizontal emittance of 1.2 nm rad at an energy of 3 GeV. The possibilities to realise the main magnetic system with high gradient integrated magnets are studied with 2D and 3D magnetic field programs. The dynamic properties for the lattice are also studied and some higher order corrections are discussed.

  16. Coding and signal processing for magnetic recording systems

    CERN Document Server

    Vasic, Bane

    2004-01-01

    RECORDING SYSTEMSA BriefHistory of Magnetic Storage, Dean PalmerPhysics of Longitudinal and Perpendicular Recording, Hong Zhou, Tom Roscamp, Roy Gustafson, Eric Boernern, and Roy ChantrellThe Physics of Optical Recording, William A. Challener and Terry W. McDanielHead Design Techniques for Recording Devices, Robert E. RottmayerCOMMUNICATION AND INFORMATION THEORY OF MAGNETIC RECORDING CHANNELSModeling the Recording Channel, Jaekyun MoonSignal and Noise Generation for Magnetic Recording Channel Simulations, Xueshi Yang and Erozan M. KurtasStatistical Analysis of Digital Signals and Systems, Dra

  17. A magnetic biosensor system for detection of E. coli

    KAUST Repository

    Li, Fuquan

    2013-07-01

    This work describes a device for detecting E. coli bacteria by manipulating superparamagnetic beads to a sensing area and immobilizing them in a trapping well. The trapping well replaces the biochemical immobilization layer, which is commonly used in magnetic biosensor systems. A concept exploiting the volume difference between bare magnetic beads and magnetic bead-bioanalyte compounds is utilized to detect E. coli bacteria. Trapped beads are detected by the help of a tunnel magneto-resistive sensor. Frequency modulation is employed, in order to increase the signal-to-noise ratio, enabling the detection of individual superparamagnetic beads of 2.8 μm in diameter. Replacing the biochemical immobilization layer by the trapping well greatly simplifies the detection process. After applying the mixture of E. coli and magnetic beads to the biosensor system, bacteria detection is achieved in a single step, within a few minutes. © 2013 IEEE.

  18. Local probing spinel and perovskite complex magnetic systems

    CERN Document Server

    De Pinho Oliveira, Goncalo; Lima Lopes, Armandina Maria

    Materials with multifunctional physical properties are crucial for the modern society, especially those which display a strong coupling between magnetic, lattice and polar degrees of freedom. This by far unexploited capability promises new paradigm-shift technologies for cooling technologies, magnetic data storage, high-frequency magnetic devices, spintronics, and micro-electromechanical systems. Alongside with the understanding of the properties of these materials, the need to improve them and to make them smaller and more efficient is a current goal. Device miniaturization towards very high-density data storage stands also as a trend in modern science and technology. Here, the integration of several functions into one material system has become highly desirable. Research in this area has already highlighted complex magnetic materials with po- tential for multifunctional applications based on spinel type structures like CdMn2O4 or multiferroic CdCr2S4 or even RCrO3 with orthorhombically distorted perovskite ...

  19. Passive magnetic bearing systems stabilizer/bearing utilizing time-averaging of a periodic magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Post, Richard F.

    2017-10-03

    A high-stiffness stabilizer/bearings for passive magnetic bearing systems is provide where the key to its operation resides in the fact that when the frequency of variation of the repelling forces of the periodic magnet array is large compared to the reciprocal of the growth time of the unstable motion, the rotating system will feel only the time-averaged value of the force. When the time-averaged value of the force is radially repelling by the choice of the geometry of the periodic magnet array, the Earnshaw-related unstable hit motion that would occur at zero rotational speed is suppressed when the system is rotating at operating speeds.

  20. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  1. ADC's Insertion Devices and Magnetic Measurement Systems Capabilities

    Science.gov (United States)

    Deyhim, A.; Kulesza, J.

    2013-03-01

    In this paper Advance Design Consulting USA, Inc. (ADC) will discuss ADC's major improved capabilities for building Wiggler Insertion Devices, Undulator Planar Devices, Elliptical Polarizing Undulators (EPU), In-Vacuum Undulators (IVU), Cryogenically Cooled in-vacuum Undulators (CPMU), Super Conductive Undulator, and Insertion Device Magnetic Measurement Systems. ADC has designed, built and delivered Insertion Devices and Magnetic Measurement Systems to such facilities as MAX-lab (two EPUs, a Planar, and Measurement System), ALBA and ASP (Wigglers), BNL (CPMU), SSRF (two IVUs and a Measurement System), PAL (one IVU and Measurement System), NSRRC (one 4m EPU), and SRC (Planar and EPU). ADC's magnetic field measurement system is a sophisticated and sensitive machine for the measurement of magnetic fields in undulators (Planar and EPU), wigglers and in-vacuum ID units. The magnetic fields are measured using 3 axis hall-effect probes, mounted orthogonally, to a thin wand. The wand is mounted to a carriage that rides on vacuum air bearings. The base is granite. A flip coil is provided on two vertical towers with X, Y and Theta axes. Special software is provided to assist in homing, movement, and data collection and analysis.

  2. Status of the ALICE magnet system

    CERN Document Server

    Swoboda, Detlef; Pigni, L; Cacaut, D E; Kochournikov, E; Vodopyanov, A S

    2002-01-01

    ALICE is the LHC experiment dedicated to heavy ion (Pb, Ca) physics. ALICE will be installed in point 2 of LHC, the former point 2 of LEP. The luminosity at the interaction point will be in the order of 10 /sup 27/ (10/sup 31/ for p-p). Consequently, the radiation level in ALICE will be comparatively low. We will use the existing infrastructure. Therefore, no noticeable civil engineering work will be necessary. Minor modifications will be made to gain a second access to the experiment cavern-mainly for the union arm spectrometer. ALICE will reuse the L3 solenoid, which is already installed and has been used in LEP as spectrometer magnet. A dipole magnet with a very large aperture is in addition required for the Dimuon Arm spectrometer and will be installed next to the L3 solenoid. The detectors in ALICE are concentrated around the IP inside L3 (Barrel) and along the muon arm. Some small forward detectors will be located toward the injection area at a larger distance from IP (~100 m). After a review of the pre...

  3. Magnetic alignment and the Poisson alignment reference system

    Science.gov (United States)

    Griffith, L. V.; Schenz, R. F.; Sommargren, G. E.

    1990-08-01

    Three distinct metrological operations are necessary to align a free-electron laser (FEL): the magnetic axis must be located, a straight line reference (SLR) must be generated, and the magnetic axis must be related to the SLR. This article begins with a review of the motivation for developing an alignment system that will assure better than 100-μm accuracy in the alignment of the magnetic axis throughout an FEL. The 100-μm accuracy is an error circle about an ideal axis for 300 m or more. The article describes techniques for identifying the magnetic axes of solenoids, quadrupoles, and wiggler poles. Propagation of a laser beam is described to the extent of revealing sources of nonlinearity in the beam. Development of a straight-line reference based on the Poisson line, a diffraction effect, is described in detail. Spheres in a large-diameter laser beam create Poisson lines and thus provide a necessary mechanism for gauging between the magnetic axis and the SLR. Procedures for installing FEL components and calibrating alignment fiducials to the magnetic axes of the components are also described. The Poisson alignment reference system should be accurate to 25 μm over 300 m, which is believed to be a factor-of-4 improvement over earlier techniques. An error budget shows that only 25% of the total budgeted tolerance is used for the alignment reference system, so the remaining tolerances should fall within the allowable range for FEL alignment.

  4. Design of high-throughput and low-power true random number generator utilizing perpendicularly magnetized voltage-controlled magnetic tunnel junction

    Directory of Open Access Journals (Sweden)

    Hochul Lee

    2017-05-01

    Full Text Available A true random number generator based on perpendicularly magnetized voltage-controlled magnetic tunnel junction devices (MRNG is presented. Unlike MTJs used in memory applications where a stable bit is needed to store information, in this work, the MTJ is intentionally designed with small perpendicular magnetic anisotropy (PMA. This allows one to take advantage of the thermally activated fluctuations of its free layer as a stochastic noise source. Furthermore, we take advantage of the voltage dependence of anisotropy to temporarily change the MTJ state into an unstable state when a voltage is applied. Since the MTJ has two energetically stable states, the final state is randomly chosen by thermal fluctuation. The voltage controlled magnetic anisotropy (VCMA effect is used to generate the metastable state of the MTJ by lowering its energy barrier. The proposed MRNG achieves a high throughput (32 Gbps by implementing a 64×64 MTJ array into CMOS circuits and executing operations in a parallel manner. Furthermore, the circuit consumes very low energy to generate a random bit (31.5 fJ/bit due to the high energy efficiency of the voltage-controlled MTJ switching.

  5. Design of high-throughput and low-power true random number generator utilizing perpendicularly magnetized voltage-controlled magnetic tunnel junction

    Science.gov (United States)

    Lee, Hochul; Ebrahimi, Farbod; Amiri, Pedram Khalili; Wang, Kang L.

    2017-05-01

    A true random number generator based on perpendicularly magnetized voltage-controlled magnetic tunnel junction devices (MRNG) is presented. Unlike MTJs used in memory applications where a stable bit is needed to store information, in this work, the MTJ is intentionally designed with small perpendicular magnetic anisotropy (PMA). This allows one to take advantage of the thermally activated fluctuations of its free layer as a stochastic noise source. Furthermore, we take advantage of the voltage dependence of anisotropy to temporarily change the MTJ state into an unstable state when a voltage is applied. Since the MTJ has two energetically stable states, the final state is randomly chosen by thermal fluctuation. The voltage controlled magnetic anisotropy (VCMA) effect is used to generate the metastable state of the MTJ by lowering its energy barrier. The proposed MRNG achieves a high throughput (32 Gbps) by implementing a 64 ×64 MTJ array into CMOS circuits and executing operations in a parallel manner. Furthermore, the circuit consumes very low energy to generate a random bit (31.5 fJ/bit) due to the high energy efficiency of the voltage-controlled MTJ switching.

  6. Transcranial Magnetic Stimulation to Address Mild Cognitive Impairment in the Elderly: A Randomized Controlled Study

    Directory of Open Access Journals (Sweden)

    Hellen Livia Drumond Marra

    2015-01-01

    Full Text Available Transcranial magnetic stimulation (TMS is a noninvasive brain stimulation technique with potential to improve memory. Mild cognitive impairment (MCI, which still lacks a specific therapy, is a clinical syndrome associated with increased risk of dementia. This study aims to assess the effects of high-frequency repetitive TMS (HF rTMS on everyday memory of the elderly with MCI. We conducted a double-blinded randomized sham-controlled trial using rTMS over the left dorsolateral prefrontal cortex (DLPFC. Thirty-four elderly outpatients meeting Petersen’s MCI criteria were randomly assigned to receive 10 sessions of either active TMS or sham, 10 Hz rTMS at 110% of motor threshold, 2,000 pulses per session. Neuropsychological assessment at baseline, after the last session (10th and at one-month follow-up, was applied. ANOVA on the primary efficacy measure, the Rivermead Behavioural Memory Test, revealed a significant group-by-time interaction p=0.05, favoring the active group. The improvement was kept after one month. Other neuropsychological tests were heterogeneous. rTMS at 10 Hz enhanced everyday memory in elderly with MCI after 10 sessions. These findings suggest that rTMS might be effective as a therapy for MCI and probably a tool to delay deterioration.

  7. Gradual stiffness versus magnetic imaging-guided variable stiffness colonoscopes: A randomized noninferiority trial.

    Science.gov (United States)

    Garborg, Kjetil; Wiig, Håvard; Hasund, Audun; Matre, Jon; Holme, Øyvind; Noraberg, Geir; Løberg, Magnus; Kalager, Mette; Adami, Hans-Olov; Bretthauer, Michael

    2017-02-01

    Colonoscopes with gradual stiffness have recently been developed to enhance cecal intubation. We aimed to determine if the performance of gradual stiffness colonoscopes is noninferior to that of magnetic endoscopic imaging (MEI)-guided variable stiffness colonoscopes. Consecutive patients were randomized to screening colonoscopy with Fujifilm gradual stiffness or Olympus MEI-guided variable stiffness colonoscopes. The primary endpoint was cecal intubation rate (noninferiority limit 5%). Secondary endpoints included cecal intubation time. We estimated absolute risk differences with 95% confidence intervals (CIs). We enrolled 475 patients: 222 randomized to the gradual stiffness instrument, and 253 to the MEI-guided variable stiffness instrument. Cecal intubation rate was 91.7% in the gradual stiffness group versus 95.6% in the variable stiffness group. The adjusted absolute risk for cecal intubation failure was 4.3% higher in the gradual stiffness group than in the variable stiffness group (upper CI border 8.1%). Median cecal intubation time was 13 minutes in the gradual stiffness group and 10 minutes in the variable stiffness group (p < 0.001). The study is inconclusive with regard to noninferiority because the 95% CI for the difference in cecal intubation rate between the groups crosses the noninferiority margin. (ClinicalTrials.gov identifier: NCT01895504).

  8. Simulation and properties of randomly switched control systems

    Science.gov (United States)

    Allison, Andrew G.; Abbott, Derek

    1999-10-01

    Power electronics has made great advances since the introduction of the thyristor in 1958. Even a casual study of consumer electronics have steadily replaced passive circuits. Switched mode circuits can accommodate higher power densities, they are lighter, cheaper and easier to control. The use of microprocessors and microcontrollers can make switched mode circuits even more versatile. Unfortunately, there are some problems with switched mode circuits. The higher power densities handled by these circuits can cause catastrophic failure. Periodic switching can give rise to acoustic noise or undesirable electromagnetic radiation. These problems can be reduced through the use of random switching policies. One theoretical disadvantage of random switching policies is that the time averaged switched system is not strictly equivalent to the classical system with the same average parameters. The stability limits for the randomly switched and classical system are different. This is a possible area for concern, given the high power densities and the possibility of catastrophic failure. In this paper we examine the stability of randomly switched control systems. We provide simulations, some analysis and derive some practical rules for stability. We show that some randomness can be beneficial from the point of view of minimizing power spectral density of the noise waveforms in the output current.

  9. submitter Thermal, Hydraulic, and Electromagnetic Modeling of Superconducting Magnet Systems

    CERN Document Server

    Bottura, L

    2016-01-01

    Modeling techniques and tailored computational tools are becoming increasingly relevant to the design and analysis of large-scale superconducting magnet systems. Efficient and reliable tools are useful to provide an optimal forecast of the envelope of operating conditions and margins, which are difficult to test even when a prototype is available. This knowledge can be used to considerably reduce the design margins of the system, and thus the overall cost, or increase reliability during operation. An integrated analysis of a superconducting magnet system is, however, a complex matter, governed by very diverse physics. This paper reviews the wide spectrum of phenomena and provides an estimate of the time scales of thermal, hydraulic, and electromagnetic mechanisms affecting the performance of superconducting magnet systems. The analysis is useful to provide guidelines on how to divide the complex problem into building blocks that can be integrated in a design and analysis framework for a consistent multiphysic...

  10. Efficient fuzzy logic controller for magnetic levitation systems | Shu ...

    African Journals Online (AJOL)

    In this paper magnetic levitation controller using fuzzy logic is proposed. The proposed Fuzzy logic controller (FLC) is designed, and developed using triangular membership function with 7×7 rules. The system model was implemented in MATLAB/SIMULINK and the system responses to Fuzzy controller with different input ...

  11. Technical background for a demonstration magnetic levitation system

    Science.gov (United States)

    Britcher, Colin P.

    1987-01-01

    A preliminary technical assessment of the feasibility of a demonstration Magnetic Levitation system, required to support aerodynamic models with a specified clear air volume around them, is presented. Preliminary calculations of required sizes of electromagnets and power supplies are made, indicating that the system is practical. Other aspects, including model position sensing and controller design, are briefly addressed.

  12. Exploring planetary magnetic environments using magnetically unclean spacecraft: a systems approach to VEX MAG data analysis

    Directory of Open Access Journals (Sweden)

    S. A. Pope

    2011-04-01

    Full Text Available In situ measurements of the magnetic field are vital to the study of many fundamental problems in planetary research. Therefore the magnetometer experiment is a key element of the payload of Venus Express. In addition to the interaction of the solar wind with Venus, these measurements are crucial for the study of atmospheric escape and detection of lightning. However, the methodology for the magnetic field measurements had to be different to the traditional approach, because Venus Express is not a magnetically clean spacecraft. A technique based on two-point simultaneous measurements of the magnetic field and systems identification software is used to separate the natural magnetic field from the spacecraft generated interference. In this paper an overview of the techniques developed to separate these two field types and the results achieved for 1 Hz Venus Express data are presented. Previous publications suggest that the resulting Venus Express cleaned data is of comparable quality to measurements made from onboard magnetically clean spacecraft (Zhang et al., 2008a, b; Slavin et al., 2009.

  13. Magnetic axis alignment and the Poisson alignment reference system

    Science.gov (United States)

    Griffith, Lee V.; Schenz, Richard F.; Sommargren, Gary E.

    1989-01-01

    Three distinct metrological operations are necessary to align a free-electron laser (FEL): the magnetic axis must be located, a straight line reference (SLR) must be generated, and the magnetic axis must be related to the SLR. This paper begins with a review of the motivation for developing an alignment system that will assure better than 100 micrometer accuracy in the alignment of the magnetic axis throughout an FEL. The paper describes techniques for identifying the magnetic axis of solenoids, quadrupoles, and wiggler poles. Propagation of a laser beam is described to the extent of revealing sources of nonlinearity in the beam. Development and use of the Poisson line, a diffraction effect, is described in detail. Spheres in a large-diameter laser beam create Poisson lines and thus provide a necessary mechanism for gauging between the magnetic axis and the SLR. Procedures for installing FEL components and calibrating alignment fiducials to the magnetic axes of the components are also described. An error budget shows that the Poisson alignment reference system will make it possible to meet the alignment tolerances for an FEL.

  14. Wide Band Low Noise Love Wave Magnetic Field Sensor System.

    Science.gov (United States)

    Kittmann, Anne; Durdaut, Phillip; Zabel, Sebastian; Reermann, Jens; Schmalz, Julius; Spetzler, Benjamin; Meyners, Dirk; Sun, Nian X; McCord, Jeffrey; Gerken, Martina; Schmidt, Gerhard; Höft, Michael; Knöchel, Reinhard; Faupel, Franz; Quandt, Eckhard

    2018-01-10

    We present a comprehensive study of a magnetic sensor system that benefits from a new technique to substantially increase the magnetoelastic coupling of surface acoustic waves (SAW). The device uses shear horizontal acoustic surface waves that are guided by a fused silica layer with an amorphous magnetostrictive FeCoSiB thin film on top. The velocity of these so-called Love waves follows the magnetoelastically-induced changes of the shear modulus according to the magnetic field present. The SAW sensor is operated in a delay line configuration at approximately 150 MHz and translates the magnetic field to a time delay and a related phase shift. The fundamentals of this sensor concept are motivated by magnetic and mechanical simulations. They are experimentally verified using customized low-noise readout electronics. With an extremely low magnetic noise level of ≈100 pT/[Formula: see text], a bandwidth of 50 kHz and a dynamic range of 120 dB, this magnetic field sensor system shows outstanding characteristics. A range of additional measures to further increase the sensitivity are investigated with simulations.

  15. Permanent Magnetic System Design for the Wall-Climbing Robot

    Directory of Open Access Journals (Sweden)

    W. Shen

    2006-01-01

    Full Text Available This paper presents the design and analysis of the permanent magnetic system for a wall-climbing robot with permanent magnetic tracks. Based on the behaviour of gecko lizards, the architecture of the robot was designed and built, including the structure of the adhesion mechanism, the mechanical architecture and the anti-toppling mechanism. The permanent magnetic adhesion mechanism and the tracked locomotion mechanism were employed in this kind of wall-climbing robot. Through static and dynamic force analysis of the robot under different situations, design requirements for the adhesion mechanism were derived. Two different types of structures were put forward for the permanent magnetic units and are further discussed in this paper. These two types of structures are also analysed in detail. In addition, a finite-element method was used to verify the results of magnetic units. Finally, two wall-climbing robots, equipped with different magnetic systems described previously, are explained and their applications are discussed in this paper.

  16. Research on Wireless Power Transfer System via Magnetically Coupled Resonance

    Directory of Open Access Journals (Sweden)

    ZHU Meng

    2017-04-01

    Full Text Available In order to extend the transmission distance and improve the transmission efficiency of the traditional wireless power transmission(WPTsystem composed with the transmitting and receiving coil resonators based on magnetic resonance coupling,we proposed an effective method to add a magnetic core between repeating coil and receiving coil based on the single repeating three coils mode. This paper deduced a mathematical expression of the transmission efficiency,and built a model by the circuit theory,and also simulated the transmission system added with the magnetic core between repeating and receiving coil. Then we selected the flat magnetic core for test. At last,we verified the feasibility of the proposal by actual experiment.

  17. Large Kerr nonlinearity in a crystal of molecular magnets system

    Science.gov (United States)

    Feili, Sahar; Hamedi, Hamid Reza

    2014-03-01

    A novel scheme is proposed to investigate the possible giant Kerr nonlinearity in a crystal of molecular magnets. The crystal is subjected to one dc magnetic field and two probe and coupling ac magnetic fields. By studying the steady-state behavior of the medium, we show that an enhanced Kerr nonlinearity with negligible absorption can be achieved under condition of slow light levels, just by properly adjusting the coupling field. Also, the transient evolution of nonlinear dispersion is proposed. It is found that the frequency detunings of probe and coupling fields, as well as the intensity of coupling field, lead to the large Kerr nonlinearity. Our results can be used as a guideline for optimizing and controlling the switching process in the crystal of molecular magnets, which is much more practical than that in the atomic system because of its flexible design and the long relaxation times.

  18. Identification of System Parameters by the Random Decrement Technique

    DEFF Research Database (Denmark)

    Brincker, Rune; Kirkegaard, Poul Henning; Rytter, Anders

    1991-01-01

    The aim of this paper is to investigate and illustrate the possibilities of using correlation functions estimated by the Random Decrement Technique as a basis for parameter identification. A two-stage system identification system is used: first, the correlation functions are estimated by the Random...... Decrement Technique, and then the system parameters are identified from the correlation function estimates. Three different techniques are used in the parameter identification process: a simple non-parametric method, estimation of an Auto Regressive (AR) model by solving an overdetermined set of Yule......-Walker equations and finally, least-square fitting of the theoretical correlation function. The results are compared to the results of fitting an Auto Regressive Moving Average (ARMA) model directly to the system output from a single-degree-of-freedom system loaded by white noise....

  19. Recoverable Random Numbers in an Internet of Things Operating System

    Directory of Open Access Journals (Sweden)

    Taeill Yoo

    2017-03-01

    Full Text Available Over the past decade, several security issues with Linux Random Number Generator (LRNG on PCs and Androids have emerged. The main problem involves the process of entropy harvesting, particularly at boot time. An entropy source in the input pool of LRNG is not transferred into the non-blocking output pool if the entropy counter of the input pool is less than 192 bits out of 4098 bits. Because the entropy estimation of LRNG is highly conservative, the process may require more than one minute for starting the transfer. Furthermore, the design principle of the estimation algorithm is not only heuristic but also unclear. Recently, Google released an Internet of Things (IoT operating system called Brillo based on the Linux kernel. We analyze the behavior of the random number generator in Brillo, which inherits that of LRNG. In the results, we identify two features that enable recovery of random numbers. With these features, we demonstrate that random numbers of 700 bytes at boot time can be recovered with the success probability of 90% by using time complexity for 5.20 × 2 40 trials. Therefore, the entropy of random numbers of 700 bytes is merely about 43 bits. Since the initial random numbers are supposed to be used for sensitive security parameters, such as stack canary and key derivation, our observation can be applied to practical attacks against cryptosystem.

  20. Latest news from the Magnet System

    CERN Multimedia

    Delruelle, N; Ruber, R; Zaitsev, I

    The Last Barrel Toroid Coil Successfully Tested From June 6th to the 14th the last of the eight Barrel Toroid coils was tested on-surface (i.e. before being lowered into the ATLAS cavern). In the very early morning of June 7th, the coil reached the nominal operation current, 20.5 kA, and the maximum test current, 22 kA, without any problem. The electrical, thermal and mechanical behaviour of the coil was as expected and no 'strange' or abnormal phenomena were observed. Directly after a slow dump of the current, a second ramp to maximum current was performed, followed by a provoked quench (fast dump). The figure below shows the magnet current during these two ramps versus time. Several additional quenches and a steady state test were performed to complete the test. Presently the coil is at room temperature again and is being prepared for transport to point 1 (the ATLAS site) on 14 July. With the successful test of the eighth coil, the on-surface test program for the Barrel Toroid coils is finished. Within on...

  1. Axicell MFTF-B superconducting-magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.T.; Bulmer, R.; Hanson, C.; Hinkle, R.; Kozman, T.; Shimer, D.; Tatro, R.; VanSant, J.; Wohlwend, J.

    1982-05-05

    The Axicell MFTF-B magnet system will provide the field environment necessary for tandem mirror plasma physics investigation with thermal barriers. The performance of the device will stimulate DT to achieve energy break-even plasma conditions. Operation will be with deuterium only. There will be 24 superconducting coils consisting of 2 sets of yin-yang pairs, 14 central-cell solenoids, 2 sets of axicell mirror-coil pairs, and 2 transition coils between the axicell mirror coil-pairs and the yin-yang coils. This paper describes the progress in the design and construction of MFTF-B Superconducting-Magnet System.

  2. Identification of Curie temperature distributions in magnetic particulate systems

    Science.gov (United States)

    Waters, J.; Berger, A.; Kramer, D.; Fangohr, H.; Hovorka, O.

    2017-09-01

    This paper develops a methodology for extracting the Curie temperature distribution from magnetisation versus temperature measurements which are realizable by standard laboratory magnetometry. The method is integral in nature, robust against various sources of measurement noise, and can be adopted to a wide range of granular magnetic materials and magnetic particle systems. The validity and practicality of the method is demonstrated using large-scale Monte-Carlo simulations of an Ising-like model as a proof of concept, and general conclusions are drawn about its applicability to different classes of systems and experimental conditions.

  3. Magnetic system for small betatron with constant guide field

    Energy Technology Data Exchange (ETDEWEB)

    Chakhlov, V.L.; Zvontsov, A.A.; Simukhin, N.F.

    1975-07-01

    It is known that the use of guide fields that are constant in time in cyclic accelerators leads to an increase of the average intensity, owing to the relative long time of injection of the particles into the acceleration regime. In the design of induction accelerators with time-constant control fields, preference is given to radial-sector magnetic systems, but for similar accelerators designed for low and medium energies it is also convenient to use a spiral-sector design. A model of a magnetic system for a betatron with constant field is described.

  4. Magnetic coupling mechanisms in particle/thin film composite systems

    Directory of Open Access Journals (Sweden)

    Giovanni A. Badini Confalonieri

    2010-12-01

    Full Text Available Magnetic γ-Fe2O3 nanoparticles with a mean diameter of 20 nm and size distribution of 7% were chemically synthesized and spin-coated on top of a Si-substrate. As a result, the particles self-assembled into a monolayer with hexagonal close-packed order. Subsequently, the nanoparticle array was coated with a Co layer of 20 nm thickness. The magnetic properties of this composite nanoparticle/thin film system were investigated by magnetometry and related to high-resolution transmission electron microscopy studies. Herein three systems were compared: i.e. a reference sample with only the particle monolayer, a composite system where the particle array was ion-milled prior to the deposition of a thin Co film on top, and a similar composite system but without ion-milling. The nanoparticle array showed a collective super-spin behavior due to dipolar interparticle coupling. In the composite system, we observed a decoupling into two nanoparticle subsystems. In the ion-milled system, the nanoparticle layer served as a magnetic flux guide as observed by magnetic force microscopy. Moreover, an exchange bias effect was found, which is likely to be due to oxygen exchange between the iron oxide and the Co layer, and thus forming of an antiferromagnetic CoO layer at the γ-Fe2O3/Co interface.

  5. A quantum spin system with random interactions I

    Indian Academy of Sciences (India)

    Е3ЖY Ж-. KMS states f&Е3Жg, the spectrum of the generator of the group of unitaries which implement (Е3Ж in the GNS representation is also almost surely independent of 3. Keywords. Spin; system; quasi-local; random; dynamics; evolution; ...

  6. Random matrix theory for pseudo-Hermitian systems: Cyclic blocks

    Indian Academy of Sciences (India)

    tems, and, for Hamiltonians that break parity P and time-reversal invariance T. In an attempt to understand the ... Keywords. Random matrices; circulants; quantum chaos; PT symmetry; pseudo-. Hermiticity. ... local fluctuation properties of complex quantum systems have universal properties, independent of the details of the ...

  7. USER S GUIDE FOR THE RANDOM DRUG SCREENING SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    McNeany, Karen I [ORNL

    2013-12-01

    The Random Drug Screening System (RDSS) is a desktop computing application designed to assign nongameable drug testing dates to each member in a population of employees, within a specific time line. The program includes reporting capabilities, test form generation, unique test ID number assignment, and the ability to flag high-risk employees for a higher frequency of drug testing than the general population.

  8. A quantum spin system with random interactions I

    Indian Academy of Sciences (India)

    Keywords. Spin; system; quasi-local; random; dynamics; evolution; independent; Arveson; KMS. ... The notion of ergodicity of a measure preserving group of automorphisms of the probability space , is used to prove the almost sure independence of the Arveson spectrum S p ( T ( ) ) of T t ( ) . As a consequence, for any ...

  9. Computational Models for Creating Homogeneous Magnetic Field Generation Systems

    Directory of Open Access Journals (Sweden)

    Gerlys M. Villalobos-Fontalvo

    2013-11-01

    Full Text Available It is increasingly common to use magnetic fields at the cellular level to assess their interaction with biological tissues. The stimulation is usually done with Helmholtz coils which generate a uniform magnetic field in the center of the system. However, assessing cellular behavior with different magnetic field characteristics can be a long and expensive process. For this, it can be used computational models to previously estimate the cellular behavior due to variety of field characteristics prior to in-vitro stimulation in a laboratory. In this paper, we present a methodology for the development of three computational models of homogeneous magnetic field generation systems for possible application in cell stimulation. The models were developed in the Ansys Workbench environment and it was evaluated the magnetic flux density behavior at different configurations. The results were validated with theoretical calculations from the Biot-Savart law. Validated models will be coupled to Ansys APDL environment in order to assess the harmonic response of the system.

  10. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  11. Can repetitive magnetic stimulation improve cognition in schizophrenia? Pilot data from a randomized controlled trial.

    Science.gov (United States)

    Barr, Mera S; Farzan, Faranak; Rajji, Tarek K; Voineskos, Aristotle N; Blumberger, Daniel M; Arenovich, Tamara; Fitzgerald, Paul B; Daskalakis, Zafiris J

    2013-03-15

    Working memory represents a core cognitive domain that is impaired in schizophrenia for which there are currently no satisfactory treatments. Repetitive transcranial magnetic stimulation (rTMS) targeted over the dorsolateral prefrontal cortex has been shown to modulate neurophysiological mechanisms linked to working memory in schizophrenia and improves working memory performance in healthy subjects and might therefore represent a treatment modality for schizophrenia patients. The objectives were to evaluate the effects of rTMS on working memory performance in schizophrenia patients and evaluate whether rTMS normalizes performance to healthy subject levels. In a 4-week randomized double-blind sham-controlled pilot study design, 27 medicated schizophrenia patients were tested at the Centre for Addiction and Mental Health (a university teaching hospital that provides psychiatric care to a large urban catchment area and serves as a tertiary referral center for the province of Ontario). Patients performed the verbal working memory n-back task before and after rTMS magnetic resonance image targeted bilaterally sequentially to left and right dorsolateral prefrontal cortex 750 pulses/side at 20 Hz for 20 treatments. The main outcome measure was mean magnitude of change in the n-back accuracy for target responses with active (n = 13) or sham (n = 12) rTMS treatment course. The rTMS significantly improved 3-back accuracy for targets compared with placebo sham (Cohen's d = .92). The improvement in 3-back accuracy was also found to be at a level comparable to healthy subjects. These pilot data suggest that bilateral rTMS might be a novel, efficacious, and safe treatment for working memory deficits in patients with schizophrenia. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  12. Identification of System Parameters by the Random Decrement Technique

    DEFF Research Database (Denmark)

    Brincker, Rune; Kirkegaard, Poul Henning; Rytter, Anders

    The aim of this paper is to investigate and illustrate the possibilities of using correlation functions estimated by the Random Decrement Technique as a basis for parameter identification. A two-stage system identification method is used: first the correlation functions are estimated by the Random...... Decrement technique and then the system parameters are identified from the correlation function estimates. Three different techniques are used in the parameters identification process: a simple non-paramatic method, estimation of an Auto Regressive(AR) model by solving an overdetermined set of Yule......-Walker equations and finally least square fitting of the theoretical correlation function. The results are compared to the results of fitting an Auto Regressive Moving Average(ARMA) model directly to the system output. All investigations are performed on the simulated output from a single degree-off-freedom system...

  13. Low-cost auxiliary system for broadband NMR on strongly magnetic systems

    DEFF Research Database (Denmark)

    Nevald, Rolf; Hansen, Poul Erik

    1978-01-01

    A low cost auxiliary system consisting of He cryostat, superconducting magnet, and sample holder assembly with field probe has been constructed. The system meets the requirements of NMR on strongly paramagnetic or ordered magnetic materials, which are accurate temperature settings over a wide range...

  14. Sliding mode control of a magnetic levitation system

    Directory of Open Access Journals (Sweden)

    Al-Muthairi N. F.

    2004-01-01

    Full Text Available Sliding mode control schemes of the static and dynamic types are proposed for the control of a magnetic levitation system. The proposed controllers guarantee the asymptotic regulation of the statesof the system to their desired values. Simulation results of the proposed controllers are given to illustrate the effectiveness of them. Robustness of the control schemes to changes in the parameters of the system is also investigated.

  15. Mechanisms of magnetic stimulation of central nervous system neurons.

    Directory of Open Access Journals (Sweden)

    Tamar Pashut

    2011-03-01

    Full Text Available Transcranial magnetic stimulation (TMS is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.

  16. A New Torque Control System of Permanent Magnet Synchronous Motor

    Directory of Open Access Journals (Sweden)

    Evstratov Andrey

    2017-01-01

    Full Text Available The article describes a new approach to control of permanent magnet synchronous motor drive based on the analysis of the electromechanical transformation. The proposed control system provides quick response and low ripple of the motor torque and flux. To synthesis this control system, the authors put the electromagnetic torque and the modulus of stator flux vector as controlled values and use the Lyapunov’s second method. In addition, the stator voltage constriction and ability of low-pass filtration are taken into account. The investigation of the proposed control system has carried out with the simulation and the experimental research which have confirmed that the proposed control system correspond to all above-mentioned control tasks and the permanent magnet synchronous motor controlled under this system may be recommended to use in robotics.

  17. System architecture for a magnetically guided endovascular microcatheter.

    Science.gov (United States)

    Sincic, Ryan S; Caton, Curtis J; Lillaney, Prasheel; Goodfriend, Scott; Ni, Jason; Martin, Alastair J; Losey, Aaron D; Shah, Neel; Yee, Erin J; Evans, Lee; Malba, Vincent; Bernhardt, Anthony F; Settecase, Fabio; Cooke, Daniel L; Saeed, Maythem; Wilson, Mark W; Hetts, Steven W

    2014-02-01

    Magnetic resonance imaging (MRI) guided minimally invasive interventions are an emerging technology. We developed a microcatheter that utilizes micro-electromagnets manufactured on the distal tip, in combination with the magnetic field of a MRI scanner, to perform microcatheter steering during endovascular surgery. The aim of this study was to evaluate a user control system for operating, steering and monitoring this magnetically guided microcatheter. The magnetically-assisted remote control (MARC) microcatheter was magnetically steered within a phantom in the bore of a 1.5 T MRI scanner. Controls mounted in an interventional MRI suite, along with a graphical user interface at the MRI console, were developed with communication enabled via MRI compatible hardware modules. Microcatheter tip deflection measurements were performed by evaluating MRI steady-state free precession (SSFP) images and compared to models derived from magnetic moment interactions and composite beam mechanics. The magnitude and direction of microcatheter deflections were controlled with user hand, foot, and software controls. Data from two different techniques for measuring the microcatheter tip location within a 1.5 T MRI scanner showed correlation of magnetic deflections to our model (R(2): 0.88) with a region of linear response (R(2): 0.98). Image processing tools were successful in autolocating the in vivo microcatheter tip within MRI SSFP images. Our system showed good correlation to response curves and introduced low amounts of MRI noise artifact. The center of the artifact created by the energized microcatheter solenoid was a reliable marker for determining the degree of microcatheter deflection and auto-locating the in vivo microcatheter tip.

  18. Magnetism in a graphene-4 f -3 d hybrid system

    Science.gov (United States)

    Huttmann, Felix; Klar, David; Atodiresei, Nicolae; Schmitz-Antoniak, Carolin; Smekhova, Alevtina; Martínez-Galera, Antonio J.; Caciuc, Vasile; Bihlmayer, Gustav; Blügel, Stefan; Michely, Thomas; Wende, Heiko

    2017-02-01

    We create an interface of graphene with a metallic and magnetic support that leaves its electronic structure largely intact. This is achieved by exposing epitaxial graphene on ferromagnetic thin films of Co and Ni to vapor of the rare earth metal Eu at elevated temperatures, resulting in the intercalation of an Eu monolayer in between graphene and its substrate. The system is atomically well defined, with the Eu monolayer forming a (√{3 }×√{3 }) R 30∘ superstructure with respect to the graphene lattice. Thereby, we avoid the strong hybridization with the (Ni,Co) substrate 3 d states that otherwise drastically modify the electronic structure of graphene. This picture is suggested by our x-ray absorption spectroscopy measurements which show that after Eu intercalation the empty 2 p states of C atoms resemble more the ones measured for graphite in contrast to graphene directly bound to 3 d ferromagnetic substrates. We use x-ray magnetic circular dichroism at the Co and Ni L2 ,3 and Eu M4 ,5 as an element-specific probe to investigate magnetism in these systems. An antiferromagnetic coupling between Eu and Co/Ni moments is found, which is so strong that a magnetic moment of the Eu layer can be detected at room temperature. Density functional theory calculations confirm the antiferromagnetic coupling and provide an atomic insight into the magnetic coupling mechanism.

  19. Latest News from the Magnet System

    CERN Multimedia

    R. Ruber; R. Pengo; J. Metselaar; J. Buskop; J.J. Rabbers

    2006-01-01

    Final Connections of the Central Solenoid In the days before Christmas 2005 the highest point of ATLAS was reached as the solenoid's control dewar was put in place on top of the supporting arch structure (HS) surrounding the Barrel Toroid. From the control dewar the solenoid is connected to the cryogenic and control systems as well as to the power supply. In January 2006 the joint work was completed between dewar and chimney, containing the cryogenic and superconducting connections to the solenoid. Meanwhile the commissioning of the cryogenic distribution system in the main ATLAS cavern (UX15) was completed, after which the final connections between the solenoid and its cryogenics and control system could be started. First the huge cryogenic transfer line was put in place between the cryogenic distribution system and control dewar. A team of specialized welders worked full speed to join all the liquid and gas helium lines according to the highest quality standards. After completion the same teams then install...

  20. Control of flexible rotor systems with active magnetic bearings

    Science.gov (United States)

    Lei, Shuliang; Palazzolo, Alan

    2008-07-01

    An approach is presented for the analysis and design of magnetic suspension systems with large flexible rotordynamics models including dynamics, control, and simulation. The objective is to formulate and synthesize a large-order, flexible shaft rotordynamics model for a flywheel supported with magnetic bearings. A finite element model of the rotor system is assembled and then employed to develop a magnetic suspension compensator to provide good reliability and disturbance rejection. Stable operation over the complete speed range and optimization of the closed-loop rotordynamic properties are obtained via synthesis of eigenvalue analysis, Campbell plots, waterfall plots, and mode shapes. The large order of the rotor model and high spin speed of the rotor present a challenge for magnetic suspension control. A flywheel system is studied as an example for realizing a physical controller that provides stable rotor suspension and good disturbance rejection in all operating states. The baseline flywheel system control is determined from extensive rotordynamics synthesis and analysis for rotor critical speeds, mode shapes, frequency responses, and time responses.

  1. Spin currents and magnetization dynamics in multilayer systems

    NARCIS (Netherlands)

    van der Bijl, E.

    2014-01-01

    In this Thesis the interplay between spin currents and magnetization dynamics is investigated theoretically. With the help of a simple model the relevant physical phenomena are introduced. From this model it can be deduced that in systems with small spin-orbit coupling, current-induced torques on

  2. Optimization of Multibrid Permanent-Magnet Wind Generator Systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Li, H.; Polinder, H.

    2009-01-01

    This paper investigates the cost-effective ranges of gearbox ratios and power ratings of multibrid permanent-magnet (PM) wind generator systems by using a design optimization method. First, the analytical model of a multibrid wind turbine concept consisting of a single-stage gearbox and a three...

  3. Identification of Parameters in Active Magnetic Bearing Systems

    DEFF Research Database (Denmark)

    Lauridsen, Jonas Skjødt; Voigt, Andreas Jauernik; Mandrup-Poulsen, Christian

    2016-01-01

    A method for identifying uncertain parameters in Active Magnetic Bearing (AMB) based rotordynamic systems is introduced and adapted for experimental application. The Closed Loop Identification (CLI) method is utilised to estimate the current/force factors Ki and the displacement/force factors Ks...

  4. Crystalline structure and magnetic properties of Fe2CrSi Heusler alloy films: New ferromagnetic material for high-performance magnetic random access memory

    Science.gov (United States)

    Yoshimura, S.; Asano, H.; Nakamura, Y.; Yamaji, K.; Takeda, Y.; Matsui, M.; Ishida, S.; Nozaki, Y.; Matsuyama, K.

    2008-04-01

    A new Heusler alloy, Fe2CrSi, which has high spin polarization (P), low saturation magnetization (Ms), and a low Curie temperature (TC), was investigated in order to fabricate high-performance magnetic tunnel junctions (MTJs) with a high tunnel magnetoresistance ratio and with low critical current for the spin-transfer switching method, or a low switching field for the thermally assisted magnetization reversal technique. The main results are as follows: (1) P and the magnetic moment of Fe2CrSi with an L21 structure were 0.98 and 1.98μB/f.u., respectively, according to density of states calculations. (2) Fe2CrSi films show the (100) orientation with a B2 structure on a MgO substrate upon a thermal treatment with optimum temperature and duration. (3) Fe2CrSi films have Ms and TC values of 385emu /cm3 and 630K, respectively. (4) The (100) oriented epitaxial MTJs are produced with Fe2CrSi films fabricated with the optimized thermal treatment condition. It is found that the Fe2CrSi Heusler alloy films are a suitable ferromagnetic material for high-performance magnetic random access memory.

  5. Efficient Fuzzy Logic Controller for Magnetic Levitation Systems

    Directory of Open Access Journals (Sweden)

    D. S. Shu’aibu

    2016-12-01

    Full Text Available Magnetic levitation is a system of suspending a body or a complete system against gravity. Suspending a system in air against gravity without using fixed structure for supporting is highly unstable and complex. In the previous research many techniques of stabilizing magnetic levitation systems were discussed. In this paper magnetic levitation controller using fuzzy logic is proposed. The proposed Fuzzy logic controller (FLC is designed, and developed using triangular membership function with 7×7 rules. The system model was implemented in MATLAB/SIMULINK and the system responses to Fuzzy controller with different input signals were investigated. Using unit step input signal, the proposed controller has a settling time of 0.35 secs, percentage overshoot of 0% and there is no oscillation. The proposed controller is validated with a model of an existing practical conventional proportional plus derivatives (PD controller. The PD controller has a settling time of 0.45 secs, percentage overshoot of 7% and with oscillation. Similarly, with sinusoidal input, the FLC has a phase shift and peak response of 0^0 and 0.9967 respectively, while PD controller has a phase shift and peak response of 24.48o and 0.9616 respectively. A disturbance signal was applied to the input of the control system. Fuzzy controller succeeded in rejecting the disturbance signal without further turning of the parameters whereby PD controller failed.

  6. Design of a Magnet System for a Muon Cooling Ring

    CERN Document Server

    Kahn, Stephen A; Garren, Albert A; Kirk, Harold G; Mills, Frederick E

    2005-01-01

    A hydrogen gas filled muon cooling ring appears to be a promising approach to reducing the emittance of a muon beam for use in a neutrino factory or a muon collider. A small muon cooling ring is being studied to test the feasibility of cooling by this method. This paper describes the magnet system to circulate the muons. The magnet design is optimized to produce a large dynamic aperture to contain the muon beam with minimum losses. Muons are tracked through the field to verify the design.

  7. Photovoltaic-wind hybrid system for permanent magnet DC motor

    Science.gov (United States)

    Nasir, M. N. M.; Lada, M. Y.; Baharom, M. F.; Jaafar, H. I.; Ramani, A. N.; Sulaima, M. F.

    2015-05-01

    Hybrid system of Photovoltaic (PV) - Wind turbine (WT) generation has more advantages and reliable compared to PV or wind turbine system alone. The aim of this paper is to model and design hybrid system of PV-WT supplying 100W permanent-magnet dc motor. To achieve the objective, both of PV and WT are connected to converter in order to get the same source of DC supply. Then both sources were combined and straightly connected to 100W permanent magnet dc motor. All the works in this paper is only applied in circuit simulator by using Matlab Simulink. The output produced from each converter is expected to be suit to the motor specification. The output produced from each renewable energy system is as expected to be high as it can support the motor if one of them is breakdown

  8. Magnetic confinement system using charged ammonia targets

    Science.gov (United States)

    Porter, Gary D.; Bogdanoff, Anatoly

    1979-01-01

    A system for guiding charged laser targets to a predetermined focal spot of a laser along generally arbitrary, and especially horizontal, directions which comprises a series of electrostatic sensors which provide inputs to a computer for real time calculation of position, velocity, and direction of the target along an initial injection trajectory, and a set of electrostatic deflection means, energized according to a calculated output of said computer, to change the target trajectory to intercept the focal spot of the laser which is triggered so as to illuminate the target of the focal spot.

  9. Non-contacting "snubber bearing" for passive magnetic bearing systems

    Science.gov (United States)

    Post, Richard F

    2017-08-22

    A new non-contacting magnetic "snubber" bearing is provided for application to rotating systems such as vehicular electromechanical battery systems subject to frequent accelerations. The design is such that in the equilibrium position the drag force of the snubber is very small (milliwatts). However in a typical case, if the rotor is displaced by as little as 2 millimeters a large restoring force is generated without any physical contact between the stationary and rotating parts of the snubber bearing.

  10. Pattern formation in diffusive excitable systems under magnetic flow effects

    Science.gov (United States)

    Mvogo, Alain; Takembo, Clovis N.; Ekobena Fouda, H. P.; Kofané, Timoléon C.

    2017-07-01

    We study the spatiotemporal formation of patterns in a diffusive FitzHugh-Nagumo network where the effect of electromagnetic induction has been introduced in the standard mathematical model by using magnetic flux, and the modulation of magnetic flux on membrane potential is realized by using memristor coupling. We use the multi-scale expansion to show that the system equations can be reduced to a single differential-difference nonlinear equation. The linear stability analysis is performed and discussed with emphasis on the impact of magnetic flux. It is observed that the effect of memristor coupling importantly modifies the features of modulational instability. Our analytical results are supported by the numerical experiments, which reveal that the improved model can lead to nonlinear quasi-periodic spatiotemporal patterns with some features of synchronization. It is observed also the generation of pulses and rhythmics behaviors like breathing or swimming which are important in brain researches.

  11. Magnetic resonance imaging of living systems by remote detection

    Science.gov (United States)

    Wemmer, David; Pines, Alexander; Bouchard, Louis; Xu, Shoujun; Harel, Elad; Budker, Dmitry; Lowery, Thomas; Ledbetter, Micah

    2013-10-29

    A novel approach to magnetic resonance imaging is disclosed. Blood flowing through a living system is prepolarized, and then encoded. The polarization can be achieved using permanent or superconducting magnets. The polarization may be carried out upstream of the region to be encoded or at the place of encoding. In the case of an MRI of a brain, polarization of flowing blood can be effected by placing a magnet over a section of the body such as the heart upstream of the head. Alternatively, polarization and encoding can be effected at the same location. Detection occurs at a remote location, using a separate detection device such as an optical atomic magnetometer, or an inductive Faraday coil. The detector may be placed on the surface of the skin next to a blood vessel such as a jugular vein carrying blood away from the encoded region.

  12. The Monitor online system of the OPERA muon magnetic spectrometer

    CERN Document Server

    Ugolino, U.; Acquafredda, R.; Masone, v.

    2008-01-01

    The OPERA muon magnetic spectrometer has been designed for muon detection, tracking and timing. The 44 bakelite Resistive Chambers (RPC) planes, imbibed inside the magnet iron slabs, must provide the tracking of the muon curved in the magnetic field to ease the momentum and charge measurement provided by the HPT. Furthermore, it provides the momentum for muons stopping in the iron. RPC signals will be also used as start of drift tube acquisition thanks to the very good time resolution of RPC detectors. Due to the required performances the tracking detector must be fully efficient and stable. In this conditions an online monitor is mandatory to continuously control stability of run conditions. We report the main characteristics and performances of the monitor system for the OPERA spectrometer and capabilities of the software developed for settings and data acquisition.

  13. Evolution of a magnetic-based biomolecular detection system.

    Science.gov (United States)

    Tamanaha, Cy R; Mulvaney, Shawn P; Rife, Jack C

    2009-01-01

    Amongst the plethora of affinity biosensor systems based on biomolecular recognition and labeling assays, magnetic labeling and detection has emerged as a promising approach. Magnetic labels can be detected by a wide range of non-invasive methods, are physically and chemically stable, relatively inexpensive to produce, and can be easily made biocompatible. Over a decade ago, the U. S. Naval Research Laboratory pioneered the use of giant magnetoresistive (GMR) sensors to detect biomolecules labeled with paramagnetic microbeads. Since then, our various investigations and engineering efforts have resulted in significant improvements in both the magnetoelectronic instrumentation and the assays associated with these magnetic labels. This paper and subsequent presentation provides a synopsis of the development of our technology which has evolved into a highly sensitive detection method.

  14. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  15. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  16. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  17. Development of REBCO HTS Magnet of Magnetic Bearing for Large Capacity Flywheel Energy Storage System

    Science.gov (United States)

    Mukoyama, Shinichi; Matsuoka, Taro; Furukawa, Makoto; Nakao, Kengo; Nagashima, Ken; Ogata, Masafumi; Yamashita, Tomohisa; Hasegawa, Hitoshi; Yoshizawa, Kazuhiro; Arai, Yuuki; Miyazaki, Kazuki; Horiuchi, Shinichi; Maeda, Tadakazu; Shimizu, Hideki

    A flywheel energy storage system (FESS) is a promising electrical storage system that moderates fluctuation of electrical power from renewable energy sources. The FESS can charge and discharge the surplus electrical power repetitively with the rotating energy. Particularly, the FESS that utilizes a high temperature superconducting magnetic bearing (HTS bearing) is lower loss than conventional FESS that has mechanical bearing, and has property of longer life operation than secondary batteries. The HTS bearing consists of a HTS bulk and double-pancake coils used 2nd generation REBCO wires. In the development, the HTS double-pancake coils were fabricated and were provided for a levitation test to verify the possibility of the HTS bearing. We successfully confirmed the magnetic field was achieved to design value, and levitation force in the configuration of one YBCO bulk and five double pan-cake coils was obtained to a satisfactory force of 39.2 kN (4 tons).

  18. Power Delivered to Mechanical Systems by Random Vibrations

    Directory of Open Access Journals (Sweden)

    Timothy S. Edwards

    2009-01-01

    Full Text Available This paper develops deformational response power descriptions of multiple degree-of-freedom systems due to stationary random vibration excitation. Two new concepts are developed. The deformational response power density (DRPD can be computed when a structure's natural frequencies and modal masses are available. The DRPD shows the spectral content of the deformational power delivered to a specific structure by the stationary, random excitation. This function can be found through a weighted windowing of the power spectrum of the input acceleration excitation. Deformational response input power spectra (DRIPS, similar to the input energy spectrum and shock response spectrum, give the power delivered to single-degree-of-freedom systems as a function of natural frequency. It is shown that the DRIPS is simply a smoothed version of the power spectrum of the input acceleration excitation. The DRIPS gives rise to a useful power-based data smoothing operation.

  19. May-Wigner transition in large random dynamical systems

    Science.gov (United States)

    Ipsen, J. R.

    2017-09-01

    We consider stability in a class of random non-linear dynamical systems characterised by a relaxation rate together with a Gaussian random vector field which is white-in-time and spatial homogeneous and isotropic. We will show that in the limit of large dimension there is a stability-complexity phase transition analogue to the so-called May-Wigner transition known from linear models. Our approach uses an explicit derivation of a stochastic description of the finite-time Lyapunov exponents. These exponents are given as a system of coupled Brownian motions with hyperbolic repulsion called geometric Dyson Brownian motions. We compare our results with known models from the literature.

  20. Warm magnetic measurements of MCBCs: comparison between the results obtained with the Quadrupole Industrial Magnetic Measurement and the Corrector Industrial Magnetic Measurement systems

    CERN Document Server

    Remondino, Vittorio; Catalan-Lasheras, N

    2005-01-01

    MCBCs modules are first magnetically measured at Tesla using a second-generation Corrector Industrial Magnetic Measurement (CIMM). After assembly into the SSS quadrupoles, measurements are repeated at CERN using the Quadrupole Industrial Magnetic Measurement (QIMM) system. In this note, we compare the measurements provided by the two systems. In all the 18 cases examined, the correlation found is excellent. The consistency of the results obtained indicates that both systems are effective, that modules are correctly measured by the firm personnel and that magnetic characteristics of the modules do not change during their assembly in cold masses.

  1. Magnetically switched power supply system for lasers

    Science.gov (United States)

    Pacala, Thomas J. (Inventor)

    1987-01-01

    A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

  2. Reliability Analysis of Random Vibration Transmission Path Systems

    OpenAIRE

    Wei Zhao; Yi-Min Zhang

    2017-01-01

    The vibration transmission path systems are generally composed of the vibration source, the vibration transfer path, and the vibration receiving structure. The transfer path is the medium of the vibration transmission. Moreover, the randomness of transfer path influences the transfer reliability greatly. In this paper, based on the matrix calculus, the generalized second moment technique, and the stochastic finite element theory, the effective approach for the transfer reliability of vibratio...

  3. Magnetic transition in double perovskite systems

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, O., E-mail: navarro@servidor.unam.m [Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Apdo. Postal 70-360, 04510 Mexico DF (Mexico); Aguilar, B. [Laboratorio Interinstitucional de Magnetismo Natural, Instituto de Geofisica, Sede Michoacan, Universidad Nacional Autonoma de Mexico, Morelia (Mexico); Avignon, M. [Institut Neel, CNRS and Universite Joseph Fourier, BP 166, 38042 Grenoble Cedex 9 (France)

    2010-05-15

    The search for materials having complete spin polarization and high Curie temperature have received a lot of attention in view of spintronics applications, especially the ferromagnetic (F) Sr{sub 2}FeMoO{sub 6}, because of its fairly high Curie temperature (T{sub C}= 450 K), half-metallic character, large magnetoresistance and potential applications. On the other hand, Sr{sub 2}FeWO{sub 6} is insulating and antiferromagnetic (AF) with T{sub N}=37K. With a double exchange type model it has been shown that F-AF transition can be driven by super-exchange interactions with increasing Fe-M (M=Mo, W) charge transfer energy. So, the charge transfer energy is expected to be larger in FeW than in FeMo compounds. Using a tight-binding model with the renormalized perturbation expansion technique, we determine the density of states for the AF phase and the electronic energy difference for the F- and AF-phases as a function of the Fe-M charge transfer energy. The F-AF transition in the ordered system Sr{sub 2}FeMo{sub x}W{sub 1-x}O{sub 6} occurs for xapprox0.3, in good agreement with the experimental value. We also studied the effect of the diagonal disorder in the variation of the number of conduction electrons on Fe and M sites. Finally, the behavior of the Curie temperature as a function of the Mo/W concentration is determined.

  4. MAGNETIC VT study: a prospective, multicenter, post-market randomized controlled trial comparing VT ablation outcomes using remote magnetic navigation-guided substrate mapping and ablation versus manual approach in a low LVEF population.

    Science.gov (United States)

    Di Biase, Luigi; Tung, Roderick; Szili-Torok, Tamás; Burkhardt, J David; Weiss, Peter; Tavernier, Rene; Berman, Adam E; Wissner, Erik; Spear, William; Chen, Xu; Neužil, Petr; Skoda, Jan; Lakkireddy, Dhanunjaya; Schwagten, Bruno; Lock, Ken; Natale, Andrea

    2017-04-01

    Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. Clinicaltrials.gov identifier: NCT02637947.

  5. Coarse-fine residual gravity cancellation system with magnetic levitation

    Science.gov (United States)

    Salcudean, S. E.; Davis, H.; Chen, C. T.; Goertz, D. E.; Tryggvason, B. V.

    1992-01-01

    Aircraft flight along parabolic trajectories have been proposed and executed in order to achieve low cost, near free fall conditions of moderate duration. This paper describes a six degree of freedom experiment isolation system designed to cancel out residual accelerations due to mechanical vibrations and errors in aircraft trajectory. The isolation system consists of a fine motion magnetic levitator whose stator is transported by a conventional coarse motion stage. The levitator uses wide gap voice coil actuators and has the dual purpose of isolating the experiment platform from aircraft vibrations and actively cancelling residual accelerations through feedback control. The course motion stage tracks the levitated platform in order to keep the levitator's coils centered within their matching magnetic gaps. Aspects of system design, an analysis of the proposed control strategy and simulation results are presented. Feasibility experiments are also discussed.

  6. Stability and Bifurcation in Magnetic Flux Feedback Maglev Control System

    Directory of Open Access Journals (Sweden)

    Wen-Qing Zhang

    2013-01-01

    Full Text Available Nonlinear properties of magnetic flux feedback control system have been investigated mainly in this paper. We analyzed the influence of magnetic flux feedback control system on control property by time delay and interfering signal of acceleration. First of all, we have established maglev nonlinear model based on magnetic flux feedback and then discussed hopf bifurcation’s condition caused by the acceleration’s time delay. The critical value of delayed time is obtained. It is proved that the period solution exists in maglev control system and the stable condition has been got. We obtained the characteristic values by employing center manifold reduction theory and normal form method, which represent separately the direction of hopf bifurcation, the stability of the period solution, and the period of the period motion. Subsequently, we discussed the influence maglev system on stability of by acceleration’s interfering signal and obtained the stable domain of interfering signal. Some experiments have been done on CMS04 maglev vehicle of National University of Defense Technology (NUDT in Tangshan city. The results of experiments demonstrate that viewpoints of this paper are correct and scientific. When time lag reaches the critical value, maglev system will produce a supercritical hopf bifurcation which may cause unstable period motion.

  7. Magnetic anchoring guidance system in video-assisted thoracic surgery.

    Science.gov (United States)

    Giaccone, Agnese; Solli, Piergiorgio; Bertolaccini, Luca

    2017-01-01

    The magnetic anchoring guidance system (MAGS) is one of the most promising technological innovations in minimally invasive surgery and consists in two magnetic elements matched through the abdominal or thoracic wall. The internal magnet can be inserted into the abdominal or chest cavity through a small single incision and then moved into position by manipulating the external component. In addition to a video camera system, the inner magnetic platform can house remotely controlled surgical tools thus reducing instruments fencing, a serious inconvenience of the uniportal access. The latest prototypes are equipped with self-light-emitting diode (LED) illumination and a wireless antenna for signal transmission and device controlling, which allows bypassing the obstacle of wires crossing the field of view (FOV). Despite being originally designed for laparoscopic surgery, the MAGS seems to suit optimally the characteristics of the chest wall and might meet the specific demands of video-assisted thoracic surgery (VATS) surgery in terms of ergonomics, visualization and surgical performance; moreover, it involves less risks for the patients and an improved aesthetic outcome.

  8. Simulation of random events for adaptive control systems calibration

    Directory of Open Access Journals (Sweden)

    Drăgoi Mircea Viorel

    2017-01-01

    Full Text Available The paper deals with a mathematical model that simulates the random occurrence of events during cutting processes by milling. The evolution of certain parameters that typify the cutting processes depends on predictable and non-predictable variables. In this context, either the material hardness that varies in different sides of billet, or cutting depth, can act as non-predictable variables. In order to design a response in terms of cutting parameters to non-predictable variations of inputs, a simulation of such phenomena is very useful. A mathematical model that generates random events, both in terms of non-uniform frequency and intensity is here described. A virtual instrument built in LabVIEW generates (pseudo random events based on a combination of random numbers, as the evolution of the simulated process to be much like a real one. Furthermore the user of virtual instrument can generate himself events at certain moments and of certain intensity. This can be a useful tool to study the algorithms of designing the response which should re-balance the process within adaptive control systems.

  9. Predicting Solar Flares Using SDO/HMI Vector Magnetic Data Product and Random Forest Algorithm

    Science.gov (United States)

    Liu, Chang; Deng, Na; Wang, Jason; Wang, Haimin

    2017-08-01

    Adverse space weather effects can often be traced to solar flares, prediction of which has drawn significant research interests. Many previous forecasting studies used physical parameters derived from photospheric line-of-sight field or ground-based vector field observations. The Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory produces full-disk vector magnetograms with continuous high-cadence, while flare prediction efforts utilizing this unprecedented data source are still limited. Here we report results of flare prediction using physical parameters provided by the Space-weather HMI Active Region Patches (SHARP) and related data products. We survey X-ray flares occurred from 2010 May to 2016 December, and categorize their source regions into four classes (B, C, M, and X) according to the maximum GOES magnitude of flares they generated. We then retrieve SHARP related parameters for each selected region at the beginning of its flare date to build a database. Finally, we train a machine-learning algorithm, called random forest (RF), to predict the occurrence of a certain class of flares in a given active region within 24 hours, evaluate the classifier performance using the 10-fold cross validation scheme, and characterize the results using standard performace metrics. Compared to previous works, our experiments indicate that using the HMI parameters and RF is a valid method for flare forecasting with fairly reasonable prediction performance. We also find that the total unsigned quantities of vertical current, current helicity, and flux near polarity inversion line are among the most important parameters for classifying flaring regions into different classes.

  10. Predicting Solar Flares Using SDO/HMI Vector Magnetic Data Products and the Random Forest Algorithm

    Science.gov (United States)

    Liu, Chang; Deng, Na; Wang, Jason T. L.; Wang, Haimin

    2017-07-01

    Adverse space-weather effects can often be traced to solar flares, the prediction of which has drawn significant research interests. The Helioseismic and Magnetic Imager (HMI) produces full-disk vector magnetograms with continuous high cadence, while flare prediction efforts utilizing this unprecedented data source are still limited. Here we report results of flare prediction using physical parameters provided by the Space-weather HMI Active Region Patches (SHARP) and related data products. We survey X-ray flares that occurred from 2010 May to 2016 December and categorize their source regions into four classes (B, C, M, and X) according to the maximum GOES magnitude of flares they generated. We then retrieve SHARP-related parameters for each selected region at the beginning of its flare date to build a database. Finally, we train a machine-learning algorithm, called random forest (RF), to predict the occurrence of a certain class of flares in a given active region within 24 hr, evaluate the classifier performance using the 10-fold cross-validation scheme, and characterize the results using standard performance metrics. Compared to previous works, our experiments indicate that using the HMI parameters and RF is a valid method for flare forecasting with fairly reasonable prediction performance. To our knowledge, this is the first time that RF has been used to make multiclass predictions of solar flares. We also find that the total unsigned quantities of vertical current, current helicity, and flux near the polarity inversion line are among the most important parameters for classifying flaring regions into different classes.

  11. Skew-orthogonal polynomials, differential systems and random matrix theory

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Saugata [Abdus Salam ICTP, Strada Costiera 11, 34100, Trieste (Italy)

    2007-01-26

    We study skew-orthogonal polynomials with respect to the weight function exp [ - 2V(x)], with V(x) = {sigma}{sup 2d}{sub K=1}(u{sub K}/K)x{sup K}, u{sub 2d} > 0, d > 0. A finite subsequence of such skew-orthogonal polynomials arising in the study of orthogonal and symplectic ensembles of random matrices satisfies a system of differential-difference-deformation equation. The vectors formed by such subsequence have the rank equal to the degree of the potential in the quaternion sense. These solutions satisfy certain compatibility condition and hence admit a simultaneous fundamental system of solutions.

  12. Random Vibration of Space Shuttle Weather Protection Systems

    Directory of Open Access Journals (Sweden)

    Isaac Elishakoff

    1995-01-01

    Full Text Available The article deals with random vibrations of the space shuttle weather protection systems. The excitation model represents a fit to the measured experimental data. The cross-spectral density is given as a convex combination of three exponential functions. It is shown that for the type of loading considered, the Bernoulli-Euler theory cannot be used as a simplified approach, and the structure will be more properly modeled as a Timoshenko beam. Use of the simple Bernoulli-Euler theory may result in an error of about 50% in determining the mean-square value of the bending moment in the weather protection system.

  13. Progress on PEP-II magnet power conversion system

    Energy Technology Data Exchange (ETDEWEB)

    Bellomo, P.; Genova, L. [Stanford Linear Accelerator Center, Menlo Park, CA (United States); Jackson, T. [Lawrence Berkeley National Lab., CA (United States); Shimer, D. [Lawrence Livermore National Lab., CA (United States)

    1996-06-04

    The various power systems for supplying the PEP-II DC magnets rely exclusively on switchmode conversion, utilizing a variety of means depending on the requirements. All of the larger power supplies, ranging from 10 to 200 kW, are powered from DC sources utilizing rectified 480 V AC. Choppers can be used for the series connected strings, but for smaller groups and individual magnets, inverters driving high-frequency transformers with rectifiers comprise the best approach. All of the various systems use a ``building block`` approach of multiple standard-size units connected in series or parallel to most cost-effectively deal with a great range of voltage and current requirements. Utilization of existing infrastructure from PEP-I has been a cost-effective determinant. Equipment is being purchased either off-the-shelf, through performance specification, or by hardware purchase based on design-through-prototype. The corrector magnet power system, utilizing inexpensive, off-the-shelf, four-quadrant switching motor-controllers, has already proven very reliable: 120 of the total of 900 units have been running on the injection system for four months with no failures.

  14. Random-Profiles-Based 3D Face Recognition System

    Directory of Open Access Journals (Sweden)

    Joongrock Kim

    2014-03-01

    Full Text Available In this paper, a noble nonintrusive three-dimensional (3D face modeling system for random-profile-based 3D face recognition is presented. Although recent two-dimensional (2D face recognition systems can achieve a reliable recognition rate under certain conditions, their performance is limited by internal and external changes, such as illumination and pose variation. To address these issues, 3D face recognition, which uses 3D face data, has recently received much attention. However, the performance of 3D face recognition highly depends on the precision of acquired 3D face data, while also requiring more computational power and storage capacity than 2D face recognition systems. In this paper, we present a developed nonintrusive 3D face modeling system composed of a stereo vision system and an invisible near-infrared line laser, which can be directly applied to profile-based 3D face recognition. We further propose a novel random-profile-based 3D face recognition method that is memory-efficient and pose-invariant. The experimental results demonstrate that the reconstructed 3D face data consists of more than 50 k 3D point clouds and a reliable recognition rate against pose variation.

  15. Superconducting magnetic control system for manipulation of particulate matter and magnetic probes in medical and industrial applications

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yung Sheng; Hull, John R.; Askew, Thomas R.

    2006-07-11

    A system and method of controlling movement of magnetic material with at least first and second high temperature superconductors at spaced locations. A plurality of solenoids are associated with the superconductors to induce a persistent currents in preselected high temperature superconductors establishing a plurality of magnetic fields in response to pulsed currents introduced to one or more of the solenoids. Control mechanism in communication with said solenoids and/or said high temperature superconductors are used to demagnetize selected ones of the high temperature superconductors to reduce the magnetic fields substantially to zero. Magnetic material is moved between magnetic fields by establishing the presence thereof and thereafter reducing magnetic fields substantially to zero and establishing magnetic fields in other superconductors arranged in a predetermined configuration.

  16. Interference-aware random beam selection for spectrum sharing systems

    KAUST Repository

    Abdallah, Mohamed M.

    2012-09-01

    Spectrum sharing systems have been introduced to alleviate the problem of spectrum scarcity by allowing secondary unlicensed networks to share the spectrum with primary licensed networks under acceptable interference levels to the primary users. In this paper, we develop interference-aware random beam selection schemes that provide enhanced throughput for the secondary link under the condition that the interference observed at the primary link is within a predetermined acceptable value. For a secondary transmitter equipped with multiple antennas, our schemes select a random beam, among a set of power- optimized orthogonal random beams, that maximizes the capacity of the secondary link while satisfying the interference constraint at the primary receiver for different levels of feedback information describing the interference level at the primary receiver. For the proposed schemes, we develop a statistical analysis for the signal-to-noise and interference ratio (SINR) statistics as well as the capacity of the secondary link. Finally, we present numerical results that study the effect of system parameters including number of beams and the maximum transmission power on the capacity of the secondary link attained using the proposed schemes. © 2012 IEEE.

  17. Designing Flexible Neuro-Fuzzy System Based on Sliding Mode Controller for Magnetic Levitation Systems

    OpenAIRE

    Zahra Mohammadi; Mohammad Teshnehlab; Mahdi Aliyari Shoorehdeli

    2011-01-01

    This study presents a novel controller of magnetic levitation system by using new neuro-fuzzy structures which called flexible neuro-fuzzy systems. In this type of controller we use sliding mode control with neuro-fuzzy to eliminate the Jacobian of plant. At first, we control magnetic levitation system with Mamdanitype neuro-fuzzy systems and logical-type neuro-fuzzy systems separately and then we use two types of flexible neuro-fuzzy systems as controllers. Basic flexible OR-type neuro-fuzzy...

  18. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  19. Thermal Simulation of a Contactor with Feedback Controlled Magnet System

    Science.gov (United States)

    Ji, Liang; Chen, Degui; Liu, Yingyi; Li, Xingwen

    Similarities and differences of the thermal analysis issues between the intelligent and general AC contactors are analyzed. Heat source model of the magnet system is established according to the unique control mode of the intelligent AC contactor. Linking with the features common of the two kinds of contactors, the extension of the thermal analysis method of the general AC contactor to the intelligent AC contactor is demonstrated. Consequently, a comprehensive thermal analysis model considering heat sources of both main circuit and magnet system is constructed for the intelligent AC contactor. With this model, the steady-state temperature rise of the intelligent AC contactor is calculated and compared with the measurements of an actual intelligent AC contactor.

  20. Optimization of MIMO Systems Capacity Using Large Random Matrix Methods

    Directory of Open Access Journals (Sweden)

    Philippe Loubaton

    2012-11-01

    Full Text Available This paper provides a comprehensive introduction of large random matrix methods for input covariance matrix optimization of mutual information of MIMO systems. It is first recalled informally how large system approximations of mutual information can be derived. Then, the optimization of the approximations is discussed, and important methodological points that are not necessarily covered by the existing literature are addressed, including the strict concavity of the approximation, the structure of the argument of its maximum, the accuracy of the large system approach with regard to the number of antennas, or the justification of iterative water-filling optimization algorithms. While the existing papers have developed methods adapted to a specific model, this contribution tries to provide a unified view of the large system approximation approach.

  1. Functionally interpretable local coordinate systems for the upper extremity using inertial & magnetic measurement systems

    NARCIS (Netherlands)

    de Vries, W.H.; Veeger, H.E.J.; Cutti, A.G.; Baten, C.; Helm, F.C.

    2010-01-01

    Background: Inertial Magnetic Measurement Systems (IMMS) are becoming increasingly popular by allowing for measurements outside the motion laboratory. The latest models enable long term, accurate measurement of segment motion in terms of joint angles, if initial segment orientations can accurately

  2. Application of advanced composites in tokamak magnet systems

    Energy Technology Data Exchange (ETDEWEB)

    Long, C. J.

    1977-11-01

    The use of advanced (high-modulus) composites in superconducting magnets for tokamak fusion reactors is discussed. The most prominent potential application is as the structure in the pulsed poloidal-field coil system, where a significant reduction in eddy currents could be achieved. Present low-temperature data on the advanced composites are reviewed briefly; they are too meager to do more than suggest a broad class of composites for a particular application.

  3. Commissioning of the Cryogenic System for the ATLAS Superconducting Magnets

    CERN Document Server

    Delruelle, N; Bradshaw, T; Haug, F; ten Kate, H H J; Passardi, Giorgio; Pengo, R; Pezzetti, M; Pirotte, O; Rochford, J

    2006-01-01

    The paper describes the test results of the helium cryoplant for the superconducting magnets of the ATLAS particle detector at CERN. It consists of two refrigerators used in common by all the magnets and of two proximity cryogenic systems (PCS) interfacing respectively the toroids and the central solenoid. Emphasis is given to the commissioning of the refrigerators: the main unit of 6 kW equivalent capacity at 4.5 K and the thermal shield refrigerator providing 20 kW between 40 K and 80 K. The first unit is used for refrigeration at 4.5 K and for the cooling of three sets of 20 kA current leads, while the second one provides, in addition to the 20 kW refrigeration of the thermal shields, 60 kW for the cool-down to 100 K of the 660 ton cold mass of the magnets. The tests, carried out with the equipment in the final underground configuration, are extended to the PCS that includes the large liquid helium centrifugal pumps (each providing 1.2 kg/s) for forced-flow cooling of the magnets and the complex distributi...

  4. Identification of dominant modes in random dynamical and aeroelastic systems

    Science.gov (United States)

    Hossain, Md. Nurtaj; Sarkar, Soumyadipta; Ghosh, Debraj

    2015-11-01

    Identification of dominant modes is an important step in studying linearly vibrating systems, including flow-induced vibrations. In the presence of uncertainty, when some of the system parameters and the external excitation are modeled as random quantities, this step becomes more difficult. This work is aimed at giving a systematic treatment to this end. The ability to capture the time-averaged kinetic energy is chosen as the primary criterion for selection of modes. Accordingly, a methodology is proposed based on the overlap of probability density functions (pdf) of the natural and excitation frequencies, proximity of the natural frequencies of the mean or baseline system, modal participation factor, and stochastic variation of mode shapes in terms of the modes of the baseline system - termed here as statistical modal overlapping. The probabilistic descriptors of the natural frequencies and mode shapes are found by solving a random eigenvalue problem. Three distinct vibration scenarios are considered: (i) undamped and damped free vibrations of a bladed disk assembly, (ii) forced vibration of a building, and (iii) flutter of a bridge model. Through numerical studies, it is observed that the proposed methodology gives an accurate selection of modes.

  5. New magnet transport system for the LHC beam transfer lines

    CERN Multimedia

    Patrice Loïez

    2003-01-01

    The first of 700 magnets has been installed in one of the two transfer tunnels built to transfer the SPS beam into the LHC. The start of this first installation phase of the LHC transfer lines provides the opportunity to launch a new and highly original modular system for transporting and installing all kinds of magnets in very narrow tunnels. The system (pictured here in one of the tunnels) is based on very compact bogies, up to four of which can be coupled together to form a convoy. The wheels are fitted with individual motors enabling them to swivel through an angle of 90° and the convoy to move laterally. The lead vehicle is powered by an electric rail set into the roof of the tunnel. The system is backed up by electrical batteries that enable it to operate in the absence of an outside power source or in the event of power failure. Last but not least, for the long-distance transport of magnets, it can be optically guided by a line traced on the tunnel floor. The convoy moves through the particularly narr...

  6. Analysis of magnetic random telegraph noise in individual arrangements of a small number of coupled MnAs nanoclusters

    Science.gov (United States)

    Fischer, Martin; Elm, Matthias T.; Kato, Hiroaki; Sakita, Shinya; Hara, Shinjiro; Klar, Peter J.

    2015-10-01

    The temporal dependence of the resistance of MnAs nanocluster arrangements grown by selective-area metal-organic vapor-phase epitaxy is investigated at different temperatures. The resistance of such arrangements exhibits random telegraph noise with jumps between discrete resistance levels. The effect is attributed to thermally activated switching of the magnetic domain structure resulting in alterations of spin-dependent scattering between the MnAs clusters of the arrangements. The behavior can be qualitatively understood by a simple model in which it is assumed that the nanocluster arrangement consists of three domains in accordance with investigations by magnetic force microscopy. The magnetizations of the outer larger domains remain fixed, whereas the magnetization of a smaller intermediate domain (or domain wall) exhibits thermally activated switching between local minima of its energy landscape. The results of the model indicate that the time scale of an actual switching event of the entire intermediate domain comprises the nucleation of a seed domain consisting of a few thousand Mn spins followed by the transformation of the entire domain by domain-wall motion in order to reorient its magnetization.

  7. Output feedback control of a mechanical system using magnetic levitation.

    Science.gov (United States)

    Beltran-Carbajal, F; Valderrabano-Gonzalez, A; Rosas-Caro, J C; Favela-Contreras, A

    2015-07-01

    This paper presents an application of a nonlinear magnetic levitation system to the problem of efficient active control of mass-spring-damper mechanical systems. An output feedback control scheme is proposed for reference position trajectory tracking tasks on the flexible mechanical system. The electromagnetically actuated system is shown to be a differentially flat nonlinear system. An extended state estimation approach is also proposed to obtain estimates of velocity, acceleration and disturbance signals. The differential flatness structural property of the system is then employed for the synthesis of the controller and the signal estimation approach presented in this work. Some experimental and simulation results are included to show the efficient performance of the control approach and the effective estimation of the unknown signals. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Protection of Hardware: Powering Systems (Power Converter, Normal Conducting, and Superconducting Magnets)

    CERN Document Server

    Pfeffer, H.; Wolff, D.

    2016-01-01

    Along with the protection of magnets and power converters, we have added a section on personnel protection because this is our highest priority in the design and operation of power systems. Thus, our topics are the protection of people, power converters, and magnet loads (protected from the powering equipment), including normal conducting magnets and superconducting magnets.

  9. MAGNETIC MICROSPHERES AS A TARGETED DRUG DELIVERY SYSTEM : A REVIEW

    OpenAIRE

    TARUN PATEL; SHAILESH SONI; BHAUMIK THAKAR; VIKRAM PANDYA; PRAFUL BHARADIA

    2012-01-01

    The in-vivo targeting of tumors with magnetic microspheres is currently realized through the applicationof external non-uniform magnetic fields generated by rare-earth permanent magnets or electromagnets.This technique can be applied to magnetically targeted cancer therapy, magnetic embolization therapywith magnetic particles that contain anticancer agent, such as chemotherapeutic drugs or therapeuticradioisotopes. Drug targeting is one way of local or regional antitumor treatment. Magnetical...

  10. Remote tactile sensing system integrated with magnetic synapse.

    Science.gov (United States)

    Oh, Sunjong; Jung, Youngdo; Kim, Seonggi; Kim, SungJoon; Hu, Xinghao; Lim, Hyuneui; Kim, CheolGi

    2017-12-05

    Mechanoreceptors in a fingertip convert external tactile stimulations into electrical signals, which are transmitted by the nervous system through synaptic transmitters and then perceived by the brain with high accuracy and reliability. Inspired by the human synapse system, this paper reports a robust tactile sensing system consisting of a remote touch tip and a magnetic synapse. External pressure on the remote touch tip is transferred in the form of air pressure to the magnetic synapse, where its variation is converted into electrical signals. The developed system has high sensitivity and a wide dynamic range. The remote sensing system demonstrated tactile capabilities over wide pressure range with a minimum detectable pressure of 6 Pa. In addition, it could measure tactile stimulation up to 1,000 Hz without distortion and hysteresis, owing to the separation of the touching and sensing parts. The excellent performance of the system in terms of surface texture discrimination, heartbeat measurement from the human wrist, and satisfactory detection quality in water indicates that it has considerable potential for various mechanosensory applications in different environments.

  11. Fusing Markov random fields with anatomical knowledge and shape-based analysis to segment multiple sclerosis white matter lesions in magnetic resonance images of the brain

    Science.gov (United States)

    AlZubi, Stephan; Toennies, Klaus D.; Bodammer, N.; Hinrichs, Herman

    2002-05-01

    This paper proposes an image analysis system to segment multiple sclerosis lesions of magnetic resonance (MR) brain volumes consisting of 3 mm thick slices using three channels (images showing T1-, T2- and PD -weighted contrast). The method uses the statistical model of Markov Random Fields (MRF) both at low and high levels. The neighborhood system used in this MRF is defined in three types: (1) Voxel to voxel: a low-level heterogeneous neighborhood system is used to restore noisy images. (2) Voxel to segment: a fuzzy atlas, which indicates the probability distribution of each tissue type in the brain, is registered elastically with the MRF. It is used by the MRF as a-priori knowledge to correct miss-classified voxels. (3) Segment to segment: Remaining lesion candidates are processed by a feature based classifier that looks at unary and neighborhood information to eliminate more false positives. An expert's manual segmentation was compared with the algorithm.

  12. Intensity approximation of random fluctuation in complex systems

    Science.gov (United States)

    Yulmetyev, R. M.; Gafarov, F. M.; Yulmetyeva, D. G.; Emeljanova, N. A.

    2002-01-01

    The Markov and non-Markov processes in complex systems are examined with the help of dynamical information Shannon entropy method. Here we consider the essential role of two mutually independent channels of entropy involving creation of correlation and annihilation of correlation. The developed method has been used to analyze the intensity fluctuation of the complex systems of various nature: in psychology (to analyze numerical and pattern short-time human memory, to study the effect of stress on the parameters of the dynamical taping-test) and in cardiology (to analyze the random dynamics of RR-intervals in human ECG's and to diagnose various diseases of human cardiovascular systems). The received results show that the application of intensity approximation allows to improve essentially the diagnostics of parameters in the evolution of human dynamic states.

  13. Magnetic field alignment of randomly oriented, high aspect ratio silicon microwires into vertically oriented arrays.

    Science.gov (United States)

    Beardslee, Joseph A; Sadtler, Bryce; Lewis, Nathan S

    2012-11-27

    External magnetic fields have been used to vertically align ensembles of silicon microwires coated with ferromagnetic nickel films. X-ray diffraction and image analysis techniques were used to quantify the degree of vertical orientation of the microwires. The degree of vertical alignment and the minimum field strength required for alignment were evaluated as a function of the wire length, coating thickness, magnetic history, and substrate surface properties. Nearly 100% of 100 μm long, 2 μm diameter, Si microwires that had been coated with 300 nm of Ni could be vertically aligned by a 300 G magnetic field. For wires ranging from 40 to 60 μm in length, as the length of the wire increased, a higher degree of alignment was observed at lower field strengths, consistent with an increase in the available magnetic torque. Microwires that had been exposed to a magnetic sweep up to 300 G remained magnetized and, therefore, aligned more readily during subsequent magnetic field alignment sweeps. Alignment of the Ni-coated Si microwires occurred at lower field strengths on hydrophilic Si substrates than on hydrophobic Si substrates. The magnetic field alignment approach provides a pathway for the directed assembly of solution-grown semiconductor wires into vertical arrays, with potential applications in solar cells as well as in other electronic devices that utilize nano- and microscale components as active elements.

  14. A PERISHABLE PRODUCT INVENTORY SYSTEM OPERATING IN A RANDOM ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    V.S.S. Yadavalli

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: A model of a perishable product inventory system operating in a random environment is studied. For the sake of simplicity, the stochastic environment is considered to alternate randomly over time between two states 0 and 1 according to an alternating renewal process. When the environment is in state k , the items in the inventory have a perishing rate k μ , the demand rate is k λ and the replenishment cost is k CR . Assuming instantaneous replenishment at the epoch of the first demand after the stock-out and associating a Markov renewal process with the inventory system, the stationary distribution of the inventory level and the performance of various measures of the system evolution are obtained. Numerical examples illustrate the results obtained.

    AFRIKAANSE OPSOMMING: ‘n Model van ‘n voorraadsisteem van ‘n bederfbare produk wat aangehou word in ‘n toevalsomgewing word voorgehou. Die stogastiese omgewing word vir doeleindes van vereenvoudiging beskryf deur twee toestande, nul en een, wat op toevalswyse die wisselende hernuwingsproses behandel. Wanneer die omgewing in toestand k is, is die bederftempo k μ , die vraagtempo k λ , en die aanvullingskoste k CR . As aanvulling oombliklik plaasvind na vooraaduitputting en Markov-hernuwings geassosieer word met die voorraadsisteem, word die stasionêre verdeling van voorraadvlak en ander prestasiemaatstawe van die sisteem verkry. ‘n Numeriese voorbeeld ondersteun die resultate wat verkry is.

  15. Markov random fields for static foreground classification in surveillance systems

    Science.gov (United States)

    Fitzsimons, Jack K.; Lu, Thomas T.

    2014-09-01

    We present a novel technique for classifying static foreground in automated airport surveillance systems between abandoned and removed objects by representing the image as a Markov Random Field. The proposed algorithm computes and compares the net probability of the region of interest before and after the event occurs, hence finding which fits more naturally with their respective backgrounds. Having tested on a dataset from the PETS 2006, PETS 2007, AVSS20074, CVSG, VISOR, CANDELA and WCAM datasets, the algorithm has shown capable of matching the results of the state-of-the-art, is highly parallel and has a degree of robustness to noise and illumination changes.

  16. Reduction of claustrophobia with short-bore versus open magnetic resonance imaging: a randomized controlled trial.

    Directory of Open Access Journals (Sweden)

    Judith Enders

    Full Text Available Claustrophobia is a common problem precluding MR imaging. The purpose of the present study was to assess whether a short-bore or an open magnetic resonance (MR scanner is superior in alleviating claustrophobia.Institutional review board approval and patient informed consent were obtained to compare short-bore versus open MR. From June 2008 to August 2009, 174 patients (139 women; mean age = 53.1 [SD 12.8] with an overall mean score of 2.4 (SD 0.7, range 0 to 4 on the Claustrophobia Questionnaire (CLQ and a clinical indication for imaging, were randomly assigned to receive evaluation by open or by short-bore MR. The primary outcomes were incomplete MR examinations due to a claustrophobic event. Follow-up was conducted 7 months after MR imaging. The primary analysis was performed according to the intention-to-treat strategy.With 33 claustrophobic events in the short-bore group (39% [95% confidence interval [CI] 28% to 50% versus 23 in the open scanner group (26% [95% CI 18% to 37%]; P = 0.08 the difference was not significant. Patients with an event were in the examination room for 3.8 min (SD 4.4 in the short-bore and for 8.5 min (SD 7 in the open group (P = 0.004. This was due to an earlier occurrence of events in the short-bore group. The CLQ suffocation subscale was significantly associated with the occurrence of claustrophobic events (P = 0.003. New findings that explained symptoms were found in 69% of MR examinations and led to changes in medical treatment in 47% and surgery in 10% of patients. After 7 months, perceived claustrophobia increased in 32% of patients with events versus in only 11% of patients without events (P = 0.004.Even recent MR cannot prevent claustrophobia suggesting that further developments to create a more patient-centered MR scanner environment are needed.ClinicalTrials.gov NCT00715806.

  17. Reduction of claustrophobia with short-bore versus open magnetic resonance imaging: a randomized controlled trial.

    Science.gov (United States)

    Enders, Judith; Zimmermann, Elke; Rief, Matthias; Martus, Peter; Klingebiel, Randolf; Asbach, Patrick; Klessen, Christian; Diederichs, Gerd; Wagner, Moritz; Teichgräber, Ulf; Bengner, Thomas; Hamm, Bernd; Dewey, Marc

    2011-01-01

    Claustrophobia is a common problem precluding MR imaging. The purpose of the present study was to assess whether a short-bore or an open magnetic resonance (MR) scanner is superior in alleviating claustrophobia. Institutional review board approval and patient informed consent were obtained to compare short-bore versus open MR. From June 2008 to August 2009, 174 patients (139 women; mean age = 53.1 [SD 12.8]) with an overall mean score of 2.4 (SD 0.7, range 0 to 4) on the Claustrophobia Questionnaire (CLQ) and a clinical indication for imaging, were randomly assigned to receive evaluation by open or by short-bore MR. The primary outcomes were incomplete MR examinations due to a claustrophobic event. Follow-up was conducted 7 months after MR imaging. The primary analysis was performed according to the intention-to-treat strategy. With 33 claustrophobic events in the short-bore group (39% [95% confidence interval [CI] 28% to 50%) versus 23 in the open scanner group (26% [95% CI 18% to 37%]; P = 0.08) the difference was not significant. Patients with an event were in the examination room for 3.8 min (SD 4.4) in the short-bore and for 8.5 min (SD 7) in the open group (P = 0.004). This was due to an earlier occurrence of events in the short-bore group. The CLQ suffocation subscale was significantly associated with the occurrence of claustrophobic events (P = 0.003). New findings that explained symptoms were found in 69% of MR examinations and led to changes in medical treatment in 47% and surgery in 10% of patients. After 7 months, perceived claustrophobia increased in 32% of patients with events versus in only 11% of patients without events (P = 0.004). Even recent MR cannot prevent claustrophobia suggesting that further developments to create a more patient-centered MR scanner environment are needed. ClinicalTrials.gov NCT00715806.

  18. Dark field imaging system for size characterization of magnetic micromarkers

    Science.gov (United States)

    Malec, A.; Haiden, C.; Kokkinis, G.; Keplinger, F.; Giouroudi, I.

    2017-05-01

    In this paper we demonstrate a dark field video imaging system for the detection and size characterization of individual magnetic micromarkers suspended in liquid and the detection of pathogens utilizing magnetically labelled E.coli. The system follows dynamic processes and interactions of moving micro/nano objects close to or below the optical resolution limit, and is especially suitable for small sample volumes ( 10 μl). The developed detection method can be used to obtain clinical information about liquid contents when an additional biological protocol is provided, i.e., binding of microorganisms (e.g. E.coli) to specific magnetic markers. Some of the major advantages of our method are the increased sizing precision in the micro- and nano-range as well as the setup's simplicity making it a perfect candidate for miniaturized devices. Measurements can thus be carried out in a quick, inexpensive, and compact manner. A minor limitation is that the concentration range of micromarkers in a liquid sample needs to be adjusted in such a manner that the number of individual particles in the microscope's field of view is sufficient.

  19. Retrospective assessment of exposure to static magnetic fields during production and development of magnetic resonance imaging systems

    NARCIS (Netherlands)

    Bongers, Suzan; Christopher, Yvette; Engels, Hans; Slottje, Pauline; Kromhout, Hans

    2014-01-01

    At present, the relationship between chronic exposure to static magnetic fields (SMF) and health effects is unclear. We developed a task-based deterministic model for estimating historical electromagnetic field exposure from the static B-field (B0) of magnetic resonance imaging (MRI) systems, for a

  20. The polar coordinate magnetic measuring system for the axial field spectrometer magnet at the ISR-CERN

    CERN Document Server

    Swoboda, Detlef

    1981-01-01

    A system for the measurement of three-dimensional magnetic fields with nearly axial symmetry is described. The apparatus, which was used for the mapping of the field volume in the axial field spectrometer magnet of the ISR, measures in polar coordinates. The choice of the co- ordinate system and its advantages over other possible configurations is explained with particular reference to the measured magnet. The design and operation of the measuring system is described in detail, and its performance is discussed. (4 refs).

  1. Double-negative multilayer containing an extrinsic random layer thickness magnetized cold plasma photonic quantum-well defect

    Science.gov (United States)

    Nayak, Chittaranjan; Aghajamali, Alireza; Saha, Ardhendu

    2017-11-01

    Theoretically, the transmission properties of a symmetric double-negative metamaterial one-dimensional photonic crystal containing an extrinsic random layer thickness magnetized cold plasma photonic quantum-well defect structure have been investigated. From the numerical results performed by characteristics matrix method, it is found that, such type of structure possesses a transmission peak within the zero-nbar gap. To design a tunable microwave filter, the effects of many parameters such as randomness of layer thickness of the multilayer defect in terms of standard deviation (σ), strength of external magnetic field (B) and electron density of magnetized cold plasma (ne) on transmission peak is discussed. Our findings show that the histogram for the central frequency of the transmission peaks becomes wider with respect to smaller values of σ. In addition, in the case of B, our investigations also reveal that the histogram shifts to the higher frequency range and vice versa while considering the case of ne . These findings help to design a tunable filter for different microwave applications.

  2. Theoretical investigations on magnetic entropy change in amorphous and crystalline systems: Applications to RAg (R=Tb, Dy, Ho) and GdCuAl

    Energy Technology Data Exchange (ETDEWEB)

    Ranke, P.J. von, E-mail: von.ranke@uol.com.br [Instituto de Física, Universidade do Estado do Rio de Janeiro – UERJ, Rua São Francisco Xavier, 524, 20550-013 RJ (Brazil); Nóbrega, E.P. [Instituto de Física, Universidade do Estado do Rio de Janeiro – UERJ, Rua São Francisco Xavier, 524, 20550-013 RJ (Brazil); Caldas, A. [Sociedade Unificada de Ensino Superior e Cultura, SUESC, 20211-351 Rio de Janeiro, RJ (Brazil); Alho, B.P. [Instituto de Aplicação Fernando Rodrigues da Silveira, Universidade do Estado do Rio de Janeiro, Rua Santa Alexandrina, 288, 20260-232 RJ (Brazil); Ribeiro, P.O.; Alvarenga, T.S.T.; Lopes, P.H.O.; Sousa, V.S.R. de [Instituto de Física, Universidade do Estado do Rio de Janeiro – UERJ, Rua São Francisco Xavier, 524, 20550-013 RJ (Brazil); Carvalho, A. Magnus G. [Laboratório Nacional de Luz Síncrotron, CNPEM, 13083-970 Campinas, SP (Brazil); Oliveira, N.A. de [Instituto de Física, Universidade do Estado do Rio de Janeiro – UERJ, Rua São Francisco Xavier, 524, 20550-013 RJ (Brazil)

    2014-11-15

    We report theoretical investigations on the magnetic entropy changes in amorphous systems through two different assumptions. In the first assumption, the HPZ-anisotropic model is considered to deal with the random direction of magnetic moments, where the amorphous RAg (R=Tb, Dy and Ho) were used as prototypes systems. In the second assumption, the amorphisation is parameterized through the exchange interaction distribution and GdCuAl, in amorphous and crystalline structures, were considered as prototypes systems. Comparisons between the magnetic entropy changes under amorphisation and under the usual magnetic field variation were performed. The model reveals the dependence of refrigerant capacity on the amorphisation parameter, and an optimum amorphisation parameter was calculated. - Highlights: • Theoretical investigation on RAg (R=Tb, Dy and Ho) and GdCuAl amorphous alloys. • Magnetic entropy changes in GdCuAl in both amorphous and crystalline structures. • The refrigerant capacity was compared in both amorphous and crystalline phases.

  3. MX magnet system. [Electrical and engineering design characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Bulmer, R.H.; Calderon, M.O.; Cornish, D.N.; Kozman, T.A.; Sackett, S.J.

    1976-06-24

    A conceptual drawing of the MX experiment is given. The central feature of the MX is a large superconducting magnet. The magnet parameters and conductor parameters are listed. The electrical and engineering design of the magnet is given.

  4. Generation of Aptamers from A Primer-Free Randomized ssDNA Library Using Magnetic-Assisted Rapid Aptamer Selection

    Science.gov (United States)

    Tsao, Shih-Ming; Lai, Ji-Ching; Horng, Horng-Er; Liu, Tu-Chen; Hong, Chin-Yih

    2017-04-01

    Aptamers are oligonucleotides that can bind to specific target molecules. Most aptamers are generated using random libraries in the standard systematic evolution of ligands by exponential enrichment (SELEX). Each random library contains oligonucleotides with a randomized central region and two fixed primer regions at both ends. The fixed primer regions are necessary for amplifying target-bound sequences by PCR. However, these extra-sequences may cause non-specific bindings, which potentially interfere with good binding for random sequences. The Magnetic-Assisted Rapid Aptamer Selection (MARAS) is a newly developed protocol for generating single-strand DNA aptamers. No repeat selection cycle is required in the protocol. This study proposes and demonstrates a method to isolate aptamers for C-reactive proteins (CRP) from a randomized ssDNA library containing no fixed sequences at 5‧ and 3‧ termini using the MARAS platform. Furthermore, the isolated primer-free aptamer was sequenced and binding affinity for CRP was analyzed. The specificity of the obtained aptamer was validated using blind serum samples. The result was consistent with monoclonal antibody-based nephelometry analysis, which indicated that a primer-free aptamer has high specificity toward targets. MARAS is a feasible platform for efficiently generating primer-free aptamers for clinical diagnoses.

  5. Repetitive transcranial magnetic stimulation in cervical dystonia: effect of site and repetition in a randomized pilot trial.

    Directory of Open Access Journals (Sweden)

    Sarah Pirio Richardson

    Full Text Available Dystonia is characterized by abnormal posturing due to sustained muscle contraction, which leads to pain and significant disability. New therapeutic targets are needed in this disorder. The objective of this randomized, sham-controlled, blinded exploratory study is to identify a specific motor system target for non-invasive neuromodulation and to evaluate this target in terms of safety and tolerability in the cervical dystonia (CD population. Eight CD subjects were given 15-minute sessions of low-frequency (0.2 Hz repetitive transcranial magnetic stimulation (rTMS over the primary motor cortex (MC, dorsal premotor cortex (dPM, supplementary motor area (SMA, anterior cingulate cortex (ACC and a sham condition with each session separated by at least two days. The Toronto Western Spasmodic Torticollis Rating Scale (TWSTRS score was rated in a blinded fashion immediately pre- and post-intervention. Secondary outcomes included physiology and tolerability ratings. The mean change in TWSTRS severity score by site was 0.25 ± 1.7 (ACC, -2.9 ± 3.4 (dPM, -3.0 ± 4.8 (MC, -0.5 ± 1.1 (SHAM, and -1.5 ± 3.2 (SMA with negative numbers indicating improvement in symptom control. TWSTRS scores decreased from Session 1 (15.1 ± 5.1 to Session 5 (11.0 ± 7.6. The treatment was tolerable and safe. Physiology data were acquired on 6 of 8 subjects and showed no change over time. These results suggest rTMS can modulate CD symptoms. Both dPM and MC are areas to be targeted in further rTMS studies. The improvement in TWSTRS scores over time with multiple rTMS sessions deserves further evaluation.

  6. On a complex Duffing system with random excitation

    Energy Technology Data Exchange (ETDEWEB)

    Xu Yong [Department of Applied Mathematics, Northwestern Polytechnical University, Xi' an 710072 (China)], E-mail: hsux3@263.net; Xu Wei [Department of Applied Mathematics, Northwestern Polytechnical University, Xi' an 710072 (China)], E-mail: weixu@nwpu.edu.cn; Mahmoud, Gamal M. [Department of Mathematics, Faculty of Science, University of Assiut, 71516 Assiut (Egypt)], E-mail: gmahmoud@aun.edu.eg

    2008-01-15

    In this paper, we consider a complex Duffing system subjected to nonstationary random excitation of the form, z(t)+2{omega}{xi}z{sup .}(t)+{omega}{sup 2}z+{epsilon}z(t)|z(t)|{sup 2}={alpha}F(t), where z(t) is a complex function, {alpha} = 1 + i, i denotes the imaginary unit, {omega}, {xi} represent natural frequency and damping coefficient respectively, {epsilon} is the small perturbation parameter and nonlinearity strength, and F(t) is a random function. This equation with F(t) = 0 has connection to the complex nonlinear Schroedinger equation which appears in many important fields of physics. The truncated Wiener-Hermite expansion is applied to derive the deterministic integro-differential equations. These equations have been solved by the small parameter perturbation approach to describe the root mean square response. The approximate solution moments for the original systems has been obtained analytically. Figures are presented to show the effect of the nonlinearity strength and the damping coefficients, respectively.

  7. Analyze and experiment on AC magnetic field's effect to fiber optic gyroscopes in compact stabilization control systems

    Science.gov (United States)

    Zhang, Chao; Mao, Yao; Tian, Jing; Li, Zhijun

    2015-10-01

    Fiber optic gyroscopes (FOG) are getting more and more attention in areas such as stabilization control systems as they are all solid state and have a wide bandwidth. In stabilization systems that require wide bandwidth control, motors are usually used as actuating mechanism for active disturbance restrain. Voice coil motors (VCMs) are usually used in compact stabilization systems that require large torque and fast response. However, AC magnetic field, which can affect the output of FOG due to Faraday effect, will be generated during operation of VCMs. The frequency range affected by the AC magnetic field to the FOG's output is the same as VCMs drive signal frequency range, which is also exactly the stabilization system's working range. Therefore the effect of the AC magnetic field to FOGs must be evaluated to verify the feasibility of a stable system design that uses both FOGs and VCMs. In this article, the basic structure and operating principle of stabilization system is introduced. The influence of AC magnetic field to FOG is theoretically analyzed. The magnetic field generated by VCMs is numerically simulated based on the theory deduction of the magnetic field near energized wires. To verify the influence of the VCM generated magnetic field to the FOGs in practical designs, a simplified random fiber coil model is built for it's hard to accurately test the exact polarize axis's twisting rate in a fiber coil. The influence to the FOG's output of different random coil model is simulated and the result shows a same trend that the influence of the VCM's magnetic field to the FOG is reduced as the distance between the VCM and the FOG increasing. The influence of a VCM to a FOG with the same parameters is experimentally tested. In the Fourier transformed FOG data the same frequency point as the VCM drive signal frequency can be read. The result fit simulated result that as the distance increases, the influence decreases. The amplitude of the frequency point is just

  8. Evidence for consciousness-related anomalies in random physical systems

    Science.gov (United States)

    Radin, Dean I.; Nelson, Roger D.

    1989-12-01

    Speculations about the role of consciousness in physical systems are frequently observed in the literature concerned with the interpretation of quantum mechanics. While only three experimental investigations can be found on this topic in physics journals, more than 800 relevant experiments have been reported in the literature of parapsychology. A well-defined body of empirical evidence from this domain was reviewed using meta-analytic techniques to assess methodological quality and overall effect size. Results showed effects conforming to chance expectation in control conditions and unequivocal non-chance effects in experimental conditions. This quantitative literature review agrees with the findings of two earlier reviews, suggesting the existence of some form of consciousness-related anomaly in random physical systems.

  9. Novel High Temperature Magnetic Bearings for Space Vehicle Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Previous high temperature magnetic bearings employed only electromagnets. The work proposed in this SBIR program seeks to utilize High Temperature Permanent Magnets...

  10. Novel High Temperature Magnetic Bearings for Space Vehicle Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Previous high temperature magnetic bearings employed electromagnets only. The work proposed in this SBIR program seeks to utilize High Temperature Permanent Magnets...

  11. Arbitrary Finite-time Tracking Control for Magnetic Levitation Systems

    Directory of Open Access Journals (Sweden)

    Xuan-Toa Tran

    2014-10-01

    Full Text Available In this paper, an arbitrary finite-time tracking control (AFTC method is developed for magnetic levitation systems with uncertain dynamics and external disturbances. By introducing a novel augmented sliding-mode manifold function, the proposed method can eliminate the singular problem in traditional terminal sliding-mode control, as well as the reaching-phase problem. Moreover, the tracking errors can reach the reference value with faster convergence and better tracking precision in arbitrarily determined finite time. In addition, a fuzzy-arbitrary finite-time tracking control (F-AFTC scheme that combines a fuzzy technique with AFTC to enhance the robustness and sliding performance is also proposed. A fuzzy logic system is used to replace the discontinuous control term. Thus, the chattering phenomenon is resolved without degrading the tracking performance. The stability of the closed-loop system is guaranteed by the Lyapunov theory. Finally, the effectiveness of the proposed methods is illustrated by simulation and experimental study in a real magnetic levitation system.

  12. Deep brain transcranial magnetic stimulation using variable "Halo coil" system

    Science.gov (United States)

    Meng, Y.; Hadimani, R. L.; Crowther, L. J.; Xu, Z.; Qu, J.; Jiles, D. C.

    2015-05-01

    Transcranial Magnetic Stimulation has the potential to treat various neurological disorders non-invasively and safely. The "Halo coil" configuration can stimulate deeper regions of the brain with lower surface to deep-brain field ratio compared to other coil configurations. The existing "Halo coil" configuration is fixed and is limited in varying the site of stimulation in the brain. We have developed a new system based on the current "Halo coil" design along with a graphical user interface system that enables the larger coil to rotate along the transverse plane. The new system can also enable vertical movement of larger coil. Thus, this adjustable "Halo coil" configuration can stimulate different regions of the brain by adjusting the position and orientation of the larger coil on the head. We have calculated magnetic and electric fields inside a MRI-derived heterogeneous head model for various positions and orientations of the coil. We have also investigated the mechanical and thermal stability of the adjustable "Halo coil" configuration for various positions and orientations of the coil to ensure safe operation of the system.

  13. A compact permanent-magnet system for measuring magnetic circular dichroism in resonant inelastic soft X-ray scattering.

    Science.gov (United States)

    Miyawaki, Jun; Suga, Shigemasa; Fujiwara, Hidenori; Niwa, Hideharu; Kiuchi, Hisao; Harada, Yoshihisa

    2017-03-01

    A compact and portable magnet system for measuring magnetic dichroism in resonant inelastic soft X-ray scattering (SX-RIXS) has been developed at the beamline BL07LSU in SPring-8. A magnetic circuit composed of Nd-Fe-B permanent magnets, which realised ∼0.25 T at the center of an 11 mm gap, was rotatable around the axis perpendicular to the X-ray scattering plane. Using the system, a SX-RIXS spectrum was obtained under the application of the magnetic field at an angle parallel, nearly 45° or perpendicular to the incident X-rays. A dedicated sample stage was also designed to be as compact as possible, making it possible to perform SX-RIXS measurements at arbitrary incident angles by rotating the sample stage in the gap between the magnetic poles. This system enables facile studies of magnetic dichroism in SX-RIXS for various experimental geometries of the sample and the magnetic field. A brief demonstration of the application is presented.

  14. Automated Permanent Magnet Magnetization System for 8 GeV Transfer Line and Recycler Ring Production at Fermilab

    Science.gov (United States)

    Haggard, J. Eric

    1997-05-01

    The 8 GeV beam transfer line between the Fermilab Booster and the Main Injector and the Recycler antiproton storage ring are constructed using permanent magnet ferrite bricks surrounding a steel pole and housed inside a steel flux return shell. The transfer line consists of 51 dipoles, 67 gradient magnets, and 8 quadrupoles. The Recycler ring consists of approximately 350 gradient magnets and 60 quadrupoles. These magnet assemblies are being produced at Fermilab currently and as a part of the tooling required to produce these assemblies we have designed, built and put into production an automated permanent magnet magnetization system. The system includes a conventional B-2 type dipole, a Programmable Logic Controller (PLC) controlled brick mover, a hall-probe measurement station and a IBM Compatible P.C. for data acquisition. The system has been used in the production of the 8 GeV beam transfer line magnet assemblies each requiring several hundred individual permanent ma! gnets. This paper describes and i llustrates the design of the automated system, the data acquisition, use of FEA analysis in the design, and the experience we have had using this production system.

  15. Development of a micro nuclear magnetic resonance system

    Science.gov (United States)

    Goloshevsky, Artem

    Application of Nuclear Magnetic Resonance (NMR) to on-line/in-line control of industrial processes is currently limited by equipment costs and requirements for installation. A superconducting magnet generating strong fields is the most expensive part of a typical NMR instrument. In industrial environments, fringe magnetic fields make accommodation of NMR instruments difficult. However, a portable, low-cost and low-field magnetic resonance system can be used in virtually any environment. Development of a number of hardware components for a portable, low-cost NMR instrument is reported in this dissertation. Chapter one provides a discussion on a miniaturized Helmholtz spiral radio-frequency (RF) coil (average diameter equal to 3.5 mm) and an NMR probe built around a capillary (outer diameter = 1.59 mm and inner diameter = 1.02 mm) for flow imaging. Experiments of NMR spectroscopy, static and dynamic (flow) imaging, conducted with the use of the miniaturized coil, are described. Chapter two presents a microfabricated package of two biaxial gradient coils and a Helmholtz RF coil. Planar configuration of discrete wires was used to create magnetic field gradients. Performance of the microfabricated gradient coils while imaging water flow compared well with a commercial gradient set of much larger size. Chapter three reports on flow imaging experiments with power law fluids (aqueous solutions of sodium salt of carboxymethyl cellulose (CMC)) of different viscosities, carried out in the NMR probe with the miniaturized RF coil and capillary. Viscosities of the CMC solutions were determined based on the curve fits of the velocity profiles and simultaneous measurements of the flow rates. The curve fits were carried out according to the power law model equations. The NMR viscosity measurements compared well with measurements of the same CMC samples, performed on a conventional rotational rheometer. A portable, home-built transceiver, designed for NMR applications utilizing a

  16. Interplay between electric and magnetic effect in adiabatic polaritonic systems

    KAUST Repository

    Alabastri, Alessandro

    2013-01-01

    We report on the possibility of realizing adiabatic compression of polaritonic wave on a metallic conical nano-structure through an oscillating electric potential (quasi dynamic regime). By comparing this result with an electromagnetic wave excitation, we were able to relate the classical lighting-rod effect to adiabatic compression. Furthermore, we show that while the magnetic contribution plays a marginal role in the formation of adiabatic compression, it provides a blue shift in the spectral region. In particular, magnetic permeability can be used as a free parameter for tuning the polaritonic resonances. The peculiar form of adiabatic compression is instead dictated by both the source and the metal permittivity. The analysis is performed by starting from a simple electrostatic system to end with the complete electromagnetic one through intermediate situations such as the quasi-electrostatic and quasi-dynamic regimes. Each configuration is defined by a particular set of equations which allows to clearly determine the individual role played by the electric and magnetic contribution in the generation of adiabatic compression. We notice that these findings can be applied for the realization of a THz nano-metric generator. © 2013 Optical Society of America.

  17. The hobbyhorse of magnetic systems: the Ising model

    Science.gov (United States)

    Ibarra-García-Padilla, Eduardo; Gerardo Malanche-Flores, Carlos; Poveda-Cuevas, Freddy Jackson

    2016-11-01

    In undergraduate statistical mechanics courses the Ising model always plays an important role because it is the simplest non-trivial model used to describe magnetic systems. The one-dimensional model is easily solved analytically, while the two-dimensional one can be solved exactly by the Onsager solution. For this reason, numerical simulations are usually used to solve the two-dimensional model. Keeping in mind that the two-dimensional model is the platform for studying phase transitions, it is usually an exercise in computational undergraduate courses because its numerical solution is relatively simple to implement and its critical exponents are perfectly known. The purpose of this article is to present a detailed numerical study of the second-order phase transition in the two-dimensional Ising model at an undergraduate level, allowing readers not only to compare the mean-field solution, the exact solution and the numerical one through a complete study of the order parameter, the correlation function and finite-size scaling, but to present the techniques, along with hints and tips, for solving it themselves. We present the elementary theory of phase transitions and explain how to implement Markov chain Monte Carlo simulations and perform them for different lattice sizes with periodic boundary conditions. Energy, magnetization, specific heat, magnetic susceptibility and the correlation function are calculated and the critical exponents determined by finite-size scaling techniques. The importance of the correlation length as the relevant parameter in phase transitions is emphasized.

  18. Magnetism, planetary rotation and convection in the solar system

    CERN Document Server

    1985-01-01

    On the 6th, 7th' and 8th April 1983, a conference entitled "Magnetism, planetary rotation and convection in the Solar System" was held in the School of Physics at the University of Newcastle upon Tyne. The purpose of the meeting was to celebrate the 60th birthday of Prof. Stanley Keith Runcorn and his, and his students' and associates', several decades of scientific achievement. The social programme, which consisted of excursions in Northumberland and Durham with visits to ancient castles and churches, to Hexham Abbey and Durham Cathedral, and dinners in Newcastle and Durham, was greatly enjoyed by those attending the meeting and by their guests. The success ofthe scientific programme can be judged by this special edition of Geophysical Surveys which is derived mainly from the papers given at the meeting. The story starts in the late 1940s when the question of the origin of the magnetic field of the Earth and such other heavenly bodies as had at that time been discovered as having a magnetic field, was exerci...

  19. Interplay between electric and magnetic effect in adiabatic polaritonic systems.

    Science.gov (United States)

    Alabastri, Alessandro; Toma, Andrea; Liberale, Carlo; Chirumamilla, Manohar; Giugni, Andrea; De Angelis, Francesco; Das, Gobind; Di Fabrizio, Enzo; Zaccaria, Remo Proietti

    2013-03-25

    We report on the possibility of realizing adiabatic compression of polaritonic wave on a metallic conical nano-structure through an oscillating electric potential (quasi dynamic regime). By comparing this result with an electromagnetic wave excitation, we were able to relate the classical lighting-rod effect to adiabatic compression. Furthermore, we show that while the magnetic contribution plays a marginal role in the formation of adiabatic compression, it provides a blue shift in the spectral region. In particular, magnetic permeability can be used as a free parameter for tuning the polaritonic resonances. The peculiar form of adiabatic compression is instead dictated by both the source and the metal permittivity. The analysis is performed by starting from a simple electrostatic system to end with the complete electromagnetic one through intermediate situations such as the quasi-electrostatic and quasi-dynamic regimes. Each configuration is defined by a particular set of equations which allows to clearly determine the individual role played by the electric and magnetic contribution in the generation of adiabatic compression. We notice that these findings can be applied for the realization of a THz nano-metric generator.

  20. 13th International Conference on Magnetically Levitated Systems and Linear Drives

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    This report contains short papers on research being conducted throughout the world on magnetically levitated systems, mainly consisting of trains, and magnetic linear drives. These papers have been index separately elsewhere on the data base.

  1. Cluster analysis in systems of magnetic spheres and cubes

    Science.gov (United States)

    Pyanzina, E. S.; Gudkova, A. V.; Donaldson, J. G.; Kantorovich, S. S.

    2017-06-01

    In the present work we use molecular dynamics simulations and graph-theory based cluster analysis to compare self-assembly in systems of magnetic spheres, and cubes where the dipole moment is oriented along the side of the cube in the [001] crystallographic direction. We show that under the same conditions cubes aggregate far less than their spherical counterparts. This difference can be explained in terms of the volume of phase space in which the formation of the bond is thermodynamically advantageous. It follows that this volume is much larger for a dipolar sphere than for a dipolar cube.

  2. An Air Bearing Rotating Coil Magnetic Measurement System

    CERN Document Server

    Gottschalk, Stephen C; Taylor, David J; Thayer, William

    2005-01-01

    This paper describes a rotating coil magnetic measurement system supported on air bearings. The design is optimized for measurements of 0.1micron magnetic centerline changes on long, small aperture quadrupoles. Graphite impregnated epoxy resin is used for the coil holder and coil winding forms. Coil holder diameter is 11 mm with a length between supports of 750mm. A pair of coils is used to permit quadrupole bucking during centerline measurements. Coil length is 616mm, inner radius 1.82mm, outer radius 4.74mm. The key features of the mechanical system are simplicity; air bearings for accurate, repeatable measurements without needing warm up time and a vibration isolated stand that uses a steel-topped Newport optical table with air suspension. Coil rotation is achieved by a low noise servo motor controlled by a standalone Ethernet servo board running custom servo software. Coil calibration procedures that correct wire placement errors, tests for mechanical resonances, and other system checks will also be discu...

  3. Magnetic resonance imaging and nuclear magnetic resonance investigations of bentonite systems

    Energy Technology Data Exchange (ETDEWEB)

    Dvinskikh, Sergey V.; Furo, Istvan (Industrial NMR Centre and Div. of Physical Chemistry, Dept. of Chemistry, Royal Institute of Technology, Stockholm (Sweden))

    2009-09-15

    This report summarizes results from a set of magnetic resonance imaging (MRI) and nuclear magnetic resonance (NMR) experiments performed on Ca and Na montmorillonite samples interacting with water. The primary goal with these studies was to provide, in a non-invasive manner, a quantitative measure of bentonite distribution in extended samples during and after different physical processes such as swelling and sedimentation and on the time scale from minutes to years. Additionally, we also studied the distribution of foreign particles (such as native minerals as well as magnetic model particles) within bentonite systems and performed some diffusion NMR experiments with the aim of characterizing the state of colloids that form after clay dissolution. Both natural montmorillonites and purified and ion-exchanged montmorillonite clays were investigated. The primary variables were clay composition and water ionic strength. Bulk samples confined in a vertical tube and in a horizontal channel were investigated. A critical issue for the stability of clay buffer layer in deep underground repository is to prevent or minimize the release of clay particles into the water phase. In our experiments, the most significant particle losses were found for Na-MX80 clay exposed to water with low ionic strength. With increasing the concentration of CaCl{sub 2} in the water phase both swelling and particle release are slowed down but not completely eliminated due probably to gradual change of water ion content via ion exchange with the clay itself. For natural MX80 samples, in spite of significant swelling expansion, no clay particle release above the sensitivity limit of 0.001 volume% was observed. Ca-MX80 exhibited the smallest expansion and no trace of clay particle released into the aqueous phase

  4. A polarised SUSANS facility to study magnetic systems

    Indian Academy of Sciences (India)

    magnet, at a small angle to the diagonal of the rectangle. Neutrons were thus de- flected by the 'magnetic air prism' [5] of 90◦ apex angle. The magnet was fabricated by attaching eight rare earth permanent magnet slabs (2 cm wide, 5 cm long and. 1.25 cm high, maximum energy product BHmax > 30 MGOe) each, just ...

  5. Robotic telementoring/telesurgical system and randomized evaluation study.

    Science.gov (United States)

    Patriciu, Alexandru; Challacombe, Benjamin; Dasgupta, Prokar; Kavoussi, Louis; Stoianovici, Dan

    2005-01-01

    The paper presents a new telementoring system incorporating audio-video communication and remote robotic control. The system was developed around an off the shelf ISDN video conferencing system enhanced with video annotation and remote robot control features. The user can remotely control a robot of perform needle alignment and insertion in a Percutaneous access procedure. Particular attention was devoted to ensure the safety of the procedure. The data connection is continuously monitored and in the event of a failure the robot control is switched to the local operator. Two series of randomized trials were performed between Baltimore and London. The accuracy and procedure time were evaluated for manual needle placement, local robotic needle placement and remotely controlled robotic needle placement. The test showed that while the procedure time is not improved by the robotic approach there is an improvement in the accuracy of the procedure. The study showed also that there is no significant difference between the locally controlled robotic needled placement and the remotely controlled robotic needle placement. Thus, the proposed system can be safely used for remote robotic percutaneous access procedures.

  6. Preemptive queueing system with randomized push-out mechanism

    Science.gov (United States)

    Muliukha, Vladimir; Ilyashenko, Alexander; Zayats, Oleg; Zaborovsky, Vladimir

    2015-04-01

    In this article considered a queueing theory model with limited buffer size, one service channel, and two incoming flows. In this model one of the flows has a power to preempt other tasks. We call it a high-priority flow. Another one is low-priority. This priority mechanism is realized in a two different ways. The first one is a preemptive priority, which allows high-priority packets to interrupt low-priority packets in service channel and push them out. The second one is a randomized push-out mechanism with probability α, which allows us to choose what type of packets should be pushed out of the system when it is full. In this article we provide an algorithm for computing statistical characteristics of the model for all values of push-out probability α. We have used generating functions method to simplify the system of linear equations. This method allows us to reduce the order of linear equations system from k(k + 1)/2 to (k + 1). As the result we have got two effects in this model. The first one is a linear behavior of loss probabilities in the model with low overload. The second one is a "closing" of a system for low-priority packets with high overload.

  7. Ezetimibe for the treatment of nonalcoholic steatohepatitis: assessment by novel magnetic resonance imaging and magnetic resonance elastography in a randomized trial (MOZART trial).

    Science.gov (United States)

    Loomba, Rohit; Sirlin, Claude B; Ang, Brandon; Bettencourt, Ricki; Jain, Rashmi; Salotti, Joanie; Soaft, Linda; Hooker, Jonathan; Kono, Yuko; Bhatt, Archana; Hernandez, Laura; Nguyen, Phirum; Noureddin, Mazen; Haufe, William; Hooker, Catherine; Yin, Meng; Ehman, Richard; Lin, Grace Y; Valasek, Mark A; Brenner, David A; Richards, Lisa

    2015-04-01

    Ezetimibe inhibits intestinal cholesterol absorption and lowers low-density lipoprotein cholesterol. Uncontrolled studies have suggested that it reduces liver fat as estimated by ultrasound in nonalcoholic steatohepatitis (NASH). Therefore, we aimed to examine the efficacy of ezetimibe versus placebo in reducing liver fat by the magnetic resonance imaging-derived proton density-fat fraction (MRI-PDFF) and liver histology in patients with biopsy-proven NASH. In this randomized, double-blind, placebo-controlled trial, 50 patients with biopsy-proven NASH were randomized to either ezetimibe 10 mg orally daily or placebo for 24 weeks. The primary outcome was a change in liver fat as measured by MRI-PDFF in colocalized regions of interest within each of the nine liver segments. Novel assessment by two-dimensional and three-dimensional magnetic resonance elastography was also performed. Ezetimibe was not significantly better than placebo at reducing liver fat as measured by MRI-PDFF (mean difference between the ezetimibe and placebo arms -1.3%, P = 0.4). Compared to baseline, however, end-of-treatment MRI-PDFF was significantly lower in the ezetimibe arm (15%-11.6%, P < 0.016) but not in the placebo arm (18.5%-16.4%, P = 0.15). There were no significant differences in histologic response rates, serum alanine aminotransferase and aspartate aminotransferase levels, or longitudinal changes in two-dimensional and three-dimensional magnetic resonance elastography-derived liver stiffness between the ezetimibe and placebo arms. Compared to histologic nonresponders (25/35), histologic responders (10/35) had a significantly greater reduction in MRI-PDFF (-4.35 ± 4.9% versus -0.30 ± 4.1%, P < 0.019). Ezetimibe did not significantly reduce liver fat in NASH. This trial demonstrates the application of colocalization of MRI-PDFF-derived fat maps and magnetic resonance elastography-derived stiffness maps of the liver before and after treatment to noninvasively assess treatment

  8. CMOS Interface Circuits for Spin Tunneling Junction Based Magnetic Random Access Memories

    Energy Technology Data Exchange (ETDEWEB)

    Saripalli, Ganesh [Iowa State Univ., Ames, IA (United States)

    2002-01-01

    Magneto resistive memories (MRAM) are non-volatile memories which use magnetic instead of electrical structures to store data. These memories, apart from being non-volatile, offer a possibility to achieve densities better than DRAMs and speeds faster than SRAMs. MRAMs could potentially replace all computer memory RAM technologies in use today, leading to future applications like instan-on computers and longer battery life for pervasive devices. Such rapid development was made possible due to the recent discovery of large magnetoresistance in Spin tunneling junction devices. Spin tunneling junctions (STJ) are composite structures consisting of a thin insulating layer sandwiched between two magnetic layers. This thesis research is targeted towards these spin tunneling junction based Magnetic memories. In any memory, some kind of an interface circuit is needed to read the logic states. In this thesis, four such circuits are proposed and designed for Magnetic memories (MRAM). These circuits interface to the Spin tunneling junctions and act as sense amplifiers to read their magnetic states. The physical structure and functional characteristics of these circuits are discussed in this thesis. Mismatch effects on the circuits and proper design techniques are also presented. To demonstrate the functionality of these interface structures, test circuits were designed and fabricated in TSMC 0.35μ CMOS process. Also circuits to characterize the process mismatches were fabricated and tested. These results were then used in Matlab programs to aid in design process and to predict interface circuit's yields.

  9. Experimental gingivitis, bacteremia and systemic biomarkers: a randomized clinical trial.

    Science.gov (United States)

    Kinane, D F; Zhang, P; Benakanakere, M; Singleton, J; Biesbrock, A; Nonnenmacher, C; He, T

    2015-12-01

    Bacteremia and systemic inflammatory markers are associated with periodontal and systemic diseases and may be linking mechanisms between these conditions. We hypothesized that in the development of gingival inflammation, systemic markers of inflammation and bacteremia would increase. To study the effect of bacteremia on systemic inflammatory markers, we recruited 80 subjects to participate in an experimental gingivitis study. Subjects were stratified based on gender, smoking and the number of bleeding sites and then randomized to one of two groups: control group (n = 40) or experimental gingivitis group (n = 40). Subjects in the control group conducted an oral hygiene regimen: brushing twice daily with a regular sodium fluoride cavity protection dentifrice and a standard manual toothbrush, flossing twice daily, and mouth rinsing with an anti-cavity fluoride rinse once daily. The experimental group stopped brushing and flossing, and used only the fluoride anti-cavity mouth rinse for 21 d. Seventy-nine of 80 subjects were evaluable. One subject in the control group was excluded from the results due to antibiotic use during the study. Our data showed the experimental gingivitis group exhibited a significant (p gingival inflammatory indices relative to baseline and the control group but a decrease in bacteremia and soluble intercellular adhesion molecule-1 levels vs. baseline. Bacteremia was negatively correlated with gingival inflammatory indices and soluble intercellular adhesion molecule-1 levels in the experimental gingivitis group, thus negating our hypothesis. We conclude that there are marked differences in systemic cytokine levels over the course of short-term experimentally induced gingivitis and further conclude that a long-term periodontitis study must be considered to address mechanisms whereby oral diseases may affect systemic diseases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Geographic Information Systems to Assess External Validity in Randomized Trials.

    Science.gov (United States)

    Savoca, Margaret R; Ludwig, David A; Jones, Stedman T; Jason Clodfelter, K; Sloop, Joseph B; Bollhalter, Linda Y; Bertoni, Alain G

    2017-08-01

    To support claims that RCTs can reduce health disparities (i.e., are translational), it is imperative that methodologies exist to evaluate the tenability of external validity in RCTs when probabilistic sampling of participants is not employed. Typically, attempts at establishing post hoc external validity are limited to a few comparisons across convenience variables, which must be available in both sample and population. A Type 2 diabetes RCT was used as an example of a method that uses a geographic information system to assess external validity in the absence of a priori probabilistic community-wide diabetes risk sampling strategy. A geographic information system, 2009-2013 county death certificate records, and 2013-2014 electronic medical records were used to identify community-wide diabetes prevalence. Color-coded diabetes density maps provided visual representation of these densities. Chi-square goodness of fit statistic/analysis tested the degree to which distribution of RCT participants varied across density classes compared to what would be expected, given simple random sampling of the county population. Analyses were conducted in 2016. Diabetes prevalence areas as represented by death certificate and electronic medical records were distributed similarly. The simple random sample model was not a good fit for death certificate record (chi-square, 17.63; p=0.0001) and electronic medical record data (chi-square, 28.92; p<0.0001). Generally, RCT participants were oversampled in high-diabetes density areas. Location is a highly reliable "principal variable" associated with health disparities. It serves as a directly measurable proxy for high-risk underserved communities, thus offering an effective and practical approach for examining external validity of RCTs. Copyright © 2017 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Integration of Radiation-Hard Magnetic Random Access Memory with CMOS ICs

    CERN Document Server

    Cerjan, C J

    2000-01-01

    The research undertaken in this LDRD-funded project addressed the joint development of magnetic material-based nonvolatile, radiation-hard memory cells with Sandia National Laboratory. Specifically, the goal of this project was to demonstrate the intrinsic radiation-hardness of Giant Magneto-Resistive (GMR) materials by depositing representative alloy combinations upon radiation-hardened silicon-based integrated circuits. All of the stated goals of the project were achieved successfully. The necessary films were successfully deposited upon typical integrated circuits; the materials retained their magnetic field response at the highest radiation doses; and a patterning approach was developed that did not degrade the as-fabricated properties of the underlying circuitry. These results establish the feasibility of building radiation-hard magnetic memory cells.

  12. Random countable alphabet conformal iterated function systems satisfying the transversality condition

    Science.gov (United States)

    Urbański, Mariusz

    2016-03-01

    Dealing with with countable (finite and infinite alike) alphabet random conformal iterated function systems with overlaps, we formulate appropriate transversality conditions and then prove the relevant, in such a context, the Moran-Bowen formula which determines the Hausdorff dimension of random limit sets in dynamical terms. We also provide large classes of examples of such random systems satisfying the transversality condition.

  13. Heating of magnetic fluid systems driven by circularly polarized magnetic field

    Science.gov (United States)

    Ahsen, Osman O.; Yilmaz, Ugur; Deniz Aksoy, M.; Ertas, Gulay; Atalar, Ergin

    2010-10-01

    A theory is presented to calculate the heat dissipation of a magnetic suspension, a ferrofluid, driven by circularly polarized magnetic field. Theory is tested by in vitro experiments and it is shown that, regardless of the character of the relaxation process, linearly and circularly polarized magnetic field excitations, having the same root-mean-square magnitude, are equivalent in terms of heating efficiency.

  14. Of magnetic imaging system experiments and micro electro-mechanical systems "of mise and MEMS"

    Science.gov (United States)

    Patterson, William C.

    Magnetic fields can occur over an extremely broad range of amplitudes, and spatial and temporal scales. Practical scientific and engineering systems have fields ranging in strength from pico-tesla to hundreds of tesla. Furthermore, spatial variations can range in scale from nanometers to tens of meters, and temporal variations can range from picoseconds to hours. Due to these large variations, many different devices and methods have been previously designed for measuring and mapping magnetic fields. The primary application area for the systems developed here is magnetic microsystems. Such systems make use of one or more microscale electromagnets, soft magnets, and/or permanent magnets for sensors, actuators, inductors, electronics, biomedical devices, etc. A single magnet dimension may range from one mum to hundreds of mum, and the overall area of interest may span over distances of millimeters to centimeters. To map the stray fields from such structures, a field measurement tool must be capable of measuring fields ranging from mT to T, while mapping over distances of millimeters with a spatial resolution of approximately one mum. This current study is focused only on static fields, but time-varying fields are of great interest and could be addressed in further research. This research focuses on the development of two tools that meet the requirements of microscale magnetic measurements. The first tool is based on an optical method and excels at extremely rapid measurements of large spatial regions. The second tool is a raster based system that focuses on high magnetic and spatial accuracy. The optical system quantitatively maps the stray magnetic fields of microscale magnetic structures with field resolution down to 50 muT and spatial resolution down to 4 mum. The system uses a magneto-optical indicator film (MOIF) in conjunction with an upright reflective polarizing light microscope to generate optical images of the magnetic field perpendicular to the image plane

  15. Electrodeless plasma acceleration system using rotating magnetic field method

    Directory of Open Access Journals (Sweden)

    T. Furukawa

    2017-11-01

    Full Text Available We have proposed Rotating Magnetic Field (RMF acceleration method as one of electrodeless plasma accelerations. In our experimental scheme, plasma generated by an rf (radio frequency antenna, is accelerated by RMF antennas, which consist of two-pair, opposed, facing coils, and these antennas are outside of a discharge tube. Therefore, there is no wear of electrodes, degrading the propulsion performance. Here, we will introduce our RMF acceleration system developed, including the experimental device, e.g., external antennas, a tapered quartz tube, a vacuum chamber, external magnets, and a pumping system. In addition, we can change RMF operation parameters (RMF applied current IRMF and RMF current phase difference ϕ, focusing on RMF current frequency fRMF by adjusting matching conditions of RMF, and investigate the dependencies on plasma parameters (electron density ne and ion velocity vi; e.g., higher increases of ne and vi (∼360 % and 55 %, respectively than previous experimental results were obtained by decreasing fRMF from 5 MHz to 0.7 MHz, whose RMF penetration condition was better according to Milroy’s expression. Moreover, time-varying component of RMF has been measured directly to survey the penetration condition experimentally.

  16. Electrodeless plasma acceleration system using rotating magnetic field method

    Science.gov (United States)

    Furukawa, T.; Takizawa, K.; Kuwahara, D.; Shinohara, S.

    2017-11-01

    We have proposed Rotating Magnetic Field (RMF) acceleration method as one of electrodeless plasma accelerations. In our experimental scheme, plasma generated by an rf (radio frequency) antenna, is accelerated by RMF antennas, which consist of two-pair, opposed, facing coils, and these antennas are outside of a discharge tube. Therefore, there is no wear of electrodes, degrading the propulsion performance. Here, we will introduce our RMF acceleration system developed, including the experimental device, e.g., external antennas, a tapered quartz tube, a vacuum chamber, external magnets, and a pumping system. In addition, we can change RMF operation parameters (RMF applied current IRMF and RMF current phase difference ϕ, focusing on RMF current frequency fRMF) by adjusting matching conditions of RMF, and investigate the dependencies on plasma parameters (electron density ne and ion velocity vi); e.g., higher increases of ne and vi (˜360 % and 55 %, respectively) than previous experimental results were obtained by decreasing fRMF from 5 MHz to 0.7 MHz, whose RMF penetration condition was better according to Milroy's expression. Moreover, time-varying component of RMF has been measured directly to survey the penetration condition experimentally.

  17. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  18. Nanoscale magnetic stirring bars for heterogeneous catalysis in microscopic systems.

    Science.gov (United States)

    Yang, Shuliang; Cao, Changyan; Sun, Yongbin; Huang, Peipei; Wei, Fangfang; Song, Weiguo

    2015-02-23

    Nanometer-sized magnetic stirring bars containing Pd nanoparticles (denoted as Fe3 O4 -NC-PZS-Pd) for heterogeneous catalysis in microscopic system were prepared through a facile two-step process. In the hydrogenation of styrene, Fe3 O4 -NC-PZS-Pd showed an activity similar to that of the commercial Pd/C catalyst, but much better stability. In microscopic catalytic systems, Fe3 O4 -NC-PZS-Pd can effectively stir the reaction solution within microdrops to accelerate mass transfer, and displays far better catalytic activity than the commercial Pd/C for the hydrogenation of methylene blue in an array of microdroplets. These results suggested that the Fe3 O4 -NC-PZS-Pd could be used as nanoscale stirring bars in nanoreactors. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The OMERACT rheumatoid arthritis magnetic resonance imaging (MRI) scoring system

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Peterfy, Charles G.; Bird, Paul

    2017-01-01

    Objective: The Outcome Measures in Rheumatology (OMERACT) Rheumatoid Arthritis (RA) Magnetic Resonance Imaging (MRI) scoring system (RAMRIS), evaluating bone erosion, bone marrow edema/osteitis, and synovitis, was introduced in 2002, and is now the standard method of objectively quantifying...... Group, which used these data to provide updated considerations on image acquisition, RAMRIS definitions, and scoring systems for the original and new RA pathologies. Further, a research agenda was outlined. Results: Since 2002, longitudinal studies and clinical trials have documented RAMRIS variables...... with conventional radiography. Technical improvements, including higher field strengths and improved pulse sequences, allow higher image resolution and contrast-to-noise ratio. These have facilitated development and validation of scoring methods of new pathologies: joint space narrowing and tenosynovitis...

  20. Comparison of Excitation Signals in Active Magnetic Bearing System Identification

    Directory of Open Access Journals (Sweden)

    Jouni Vuojolainen

    2017-07-01

    Full Text Available Active magnetic bearings (AMBs offer frictionless suspension, vibration insulation, programmable stiffness, and damping, among other advantages, in levitated rotor applications. However, AMBs are inherently unstable and require accurate system models for the high-performance model-based multi-input multi-output control of rotor position. Control electronics with high calculation capacity and accurate sensors of AMBs provide an opportunity to implement various identification schemes. A variety of artificial excitation signal-based identification methods can thus be achieved with no additional hardware. In this paper, a selection of excitation signals, namely the pseudorandom binary sequence (PRBS, chirp signal, multisine, and stepped sine are presented, applied, and compared with the AMB system identification. From the identification experiments, the rotor-bearing system, the inner current control loop, and values of position and current stiffness are identified. Unlike recently published works considering excitation-based identification of AMB rotor systems, it is demonstrated that identification of the rotor system dynamics can be carried out using various well-established excitation signals. Application and feasibility of these excitation signals in AMB rotor systems are analyzed based on experimental results.

  1. Magnetic manipulation of superparamagnetic nanoparticles in a microfluidic system for drug delivery applications

    Energy Technology Data Exchange (ETDEWEB)

    Agiotis, L.; Theodorakos, I.; Samothrakitis, S.; Papazoglou, S.; Zergioti, I.; Raptis, Y.S.

    2016-03-01

    Magnetic nanoparticles (MNPs), such as superparamagnetic iron oxide nanoparticles (SPIONS), have attracted major interest, due to their small size and unique magnetic properties, for drug delivery applications. In this context, iron oxide nanoparticles of magnetite (Fe{sub 3}O{sub 4}) (150 nm magnetic core diameter), were used as drug carriers, aiming to form a magnetically controlled nano-platform. The navigation capabilities of the iron oxide nanoparticles in a microfluidic channel were investigated by simulating the magnetic field and the magnetic force applied on the magnetic nanoparticles inside a microfluidic chip. The simulations have been performed using finite element method (ANSY’S software). The optimum setup which intends to simulate the magnetic navigation of the nanoparticles, by the use of MRI-type fields, in the human circulatory system, consists of two parallel permanent magnets to produce a homogeneous magnetic field, in order to ensure the maximum magnetization of the magnetic nanoparticles, an electromagnet for the induction of the magnetic gradients and the creation of the magnetic force and a microfluidic setup so as to simulate the blood flow inside the human blood vessels. The magnetization of the superparamagnetic nanoparticles and the consequent magnetic torque developed by the two permanent magnets, together with the mutual interactions between the magnetized nanoparticles lead to the creation of rhabdoid aggregates in the direction of the homogeneous field. Additionally, the magnetic gradients introduced by the operation of the electromagnet are capable of directing the aggregates, as a whole, to the desired direction. By removing the magnetic fields, the aggregates are disrupted, due to the super paramagnetic nature of the nanoparticles, avoiding thus the formation of undesired thrombosis. - Highlights: • Homogeneous field yields an aggregation of particles along the lines of the field. • Additional electromagnet field rotates the

  2. Magnetically-induced solid-phase microextraction fiber actuation system for quantitative headspace and liquid sampling

    Science.gov (United States)

    Harvey, Chris; Carter, Jerry; Chambers, David M.

    2017-05-23

    A magnetically-induced SPME fiber actuation system includes a SPME fiber holder and a SPME fiber holder actuator, for holding and magnetically actuating a SPME fiber assembly. The SPME fiber holder has a plunger with a magnetic material to which the SPME fiber assembly is connected, and the magnetic SPME fiber holder actuator has an elongated barrel with a loading chamber for receiving the SPME fiber assembly-connected SPME fiber holder, and an external magnet which induces axial motion of the magnetic material of the plunger to extend/retract the SPME fiber from/into the protective needle of the SPME fiber assembly.

  3. High Field In Vivo 13C Magnetic Resonance Spectroscopy of Brain by Random Radiofrequency Heteronuclear Decoupling and Data Sampling

    Science.gov (United States)

    Li, Ningzhi; Li, Shizhe; Shen, Jun

    2017-06-01

    In vivo 13C magnetic resonance spectroscopy (MRS) is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo 13C-MRS is the high radio frequency (RF) power necessary for heteronuclear decoupling. In the common practice of in vivo 13C-MRS, alkanyl carbons are detected in the spectra range of 10-65ppm. The amplitude of decoupling pulses has to be significantly greater than the large one-bond 1H-13C scalar coupling (1JCH=125-145 Hz). Two main proton decoupling methods have been developed: broadband stochastic decoupling and coherent composite or adiabatic pulse decoupling (e.g., WALTZ); the latter is widely used because of its efficiency and superb performance under inhomogeneous B1 field. Because the RF power required for proton decoupling increases quadratically with field strength, in vivo 13C-MRS using coherent decoupling is often limited to low magnetic fields (Drug Administration (FDA). Alternately, carboxylic/amide carbons are coupled to protons via weak long-range 1H-13C scalar couplings, which can be decoupled using low RF power broadband stochastic decoupling. Recently, the carboxylic/amide 13C-MRS technique using low power random RF heteronuclear decoupling was safely applied to human brain studies at 7T. Here, we review the two major decoupling methods and the carboxylic/amide 13C-MRS with low power decoupling strategy. Further decreases in RF power deposition by frequency-domain windowing and time-domain random under-sampling are also discussed. Low RF power decoupling opens the possibility of performing in vivo 13C experiments of human brain at very high magnetic fields (such as 11.7T), where signal-to-noise ratio as well as spatial and temporal spectral resolution are more favorable than lower fields.

  4. A system identification technique based on the random decrement signatures. Part 1: Theory and simulation

    Science.gov (United States)

    Bedewi, Nabih E.; Yang, Jackson C. S.

    1987-01-01

    Identification of the system parameters of a randomly excited structure may be treated using a variety of statistical techniques. Of all these techniques, the Random Decrement is unique in that it provides the homogeneous component of the system response. Using this quality, a system identification technique was developed based on a least-squares fit of the signatures to estimate the mass, damping, and stiffness matrices of a linear randomly excited system. The mathematics of the technique is presented in addition to the results of computer simulations conducted to demonstrate the prediction of the response of the system and the random forcing function initially introduced to excite the system.

  5. System and method for heating ferrite magnet motors for low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Reddy, Patel Bhageerath; El-Refaie, Ayman Mohamed Fawzi; Huh, Kum-Kang

    2017-07-04

    A system and method for heating ferrite permanent magnets in an electrical machine is disclosed. The permanent magnet machine includes a stator assembly and a rotor assembly, with a plurality of ferrite permanent magnets disposed within the stator assembly or the rotor assembly to generate a magnetic field that interacts with a stator magnetic field to produce a torque. A controller of the electrical machine is programmed to cause a primary field current to be applied to the stator windings to generate the stator magnetic field, so as to cause the rotor assembly to rotate relative to the stator assembly. The controller is further programmed to cause a secondary current to be applied to the stator windings to selectively generate a secondary magnetic field, the secondary magnetic field inducing eddy currents in at least one of the stator assembly and the rotor assembly to heat the ferrite permanent magnets.

  6. Polymerase chain reaction system using magnetic beads for analyzing a sample that includes nucleic acid

    Science.gov (United States)

    Nasarabadi, Shanavaz [Livermore, CA

    2011-01-11

    A polymerase chain reaction system for analyzing a sample containing nucleic acid includes providing magnetic beads; providing a flow channel having a polymerase chain reaction chamber, a pre polymerase chain reaction magnet position adjacent the polymerase chain reaction chamber, and a post pre polymerase magnet position adjacent the polymerase chain reaction chamber. The nucleic acid is bound to the magnetic beads. The magnetic beads with the nucleic acid flow to the pre polymerase chain reaction magnet position in the flow channel. The magnetic beads and the nucleic acid are washed with ethanol. The nucleic acid in the polymerase chain reaction chamber is amplified. The magnetic beads and the nucleic acid are separated into a waste stream containing the magnetic beads and a post polymerase chain reaction mix containing the nucleic acid. The reaction mix containing the nucleic acid flows to an analysis unit in the channel for analysis.

  7. Efficient randomized methods for stability analysis of fluids systems

    Science.gov (United States)

    Dawson, Scott; Rowley, Clarence

    2016-11-01

    We show that probabilistic algorithms that have recently been developed for the approximation of large matrices can be utilized to numerically evaluate the properties of linear operators in fluids systems. In particular, we present an algorithm that is well suited for optimal transient growth (i.e., nonmodal stability) analysis. For non-normal systems, such analysis can be important for analyzing local regions of convective instability, and in identifying high-amplitude transients that can trigger nonlinear instabilities. Our proposed algorithms are easy to wrap around pre-existing timesteppers for linearized forward and adjoint equations, are highly parallelizable, and come with known error bounds. Furthermore, they allow for efficient computation of optimal growth modes for numerous time horizons simultaneously. We compare the proposed algorithm to both direct matrix-forming and Krylov subspace approaches on a number of test problems. We will additionally discuss the potential for randomized methods to assist more broadly in the speed-up of algorithms for analyzing both fluids data and operators. Supported by AFOSR Grant FA9550-14-1-0289.

  8. Methods, systems and devices for detecting threatening objects and for classifying magnetic data

    Energy Technology Data Exchange (ETDEWEB)

    Kotter, Dale K [Shelley, ID; Roybal, Lyle G [Idaho Falls, ID; Rohrbaugh, David T [Idaho Falls, ID; Spencer, David F [Idaho Falls, ID

    2012-01-24

    A method for detecting threatening objects in a security screening system. The method includes a step of classifying unique features of magnetic data as representing a threatening object. Another step includes acquiring magnetic data. Another step includes determining if the acquired magnetic data comprises a unique feature.

  9. Digital Control Analysis and Design of a Field-Sensed Magnetic Suspension System

    Directory of Open Access Journals (Sweden)

    Jen-Hsing Li

    2015-03-01

    Full Text Available Magnetic suspension systems are mechatronic systems and crucial in several engineering applications, such as the levitation of high-speed trains, frictionless bearings, and wind tunnels. Magnetic suspension systems are nonlinear and unstable systems; therefore, they are suitable educational benchmarks for testing various modeling and control methods. This paper presents the digital modeling and control of magnetic suspension systems. First, the magnetic suspension system is stabilized using a digital proportional-derivative controller. Subsequently, the digital model is identified using recursive algorithms. Finally, a digital mixed linear quadratic regulator (LQR/H∞ control is adopted to stabilize the magnetic suspension system robustly. Simulation examples and a real-world example are provided to demonstrate the practicality of the study results. In this study, a digital magnetic suspension system model was developed and reviewed. In addition, equivalent state and output feedback controls for magnetic suspension systems were developed. Using this method, the controller design for magnetic suspension systems was simplified, which is the novel contribution of this study. In addition, this paper proposes a complete digital controller design procedure for magnetic suspension systems.

  10. Digital control analysis and design of a field-sensed magnetic suspension system.

    Science.gov (United States)

    Li, Jen-Hsing; Chiou, Juing-Shian

    2015-03-13

    Magnetic suspension systems are mechatronic systems and crucial in several engineering applications, such as the levitation of high-speed trains, frictionless bearings, and wind tunnels. Magnetic suspension systems are nonlinear and unstable systems; therefore, they are suitable educational benchmarks for testing various modeling and control methods. This paper presents the digital modeling and control of magnetic suspension systems. First, the magnetic suspension system is stabilized using a digital proportional-derivative controller. Subsequently, the digital model is identified using recursive algorithms. Finally, a digital mixed linear quadratic regulator (LQR)/H∞ control is adopted to stabilize the magnetic suspension system robustly. Simulation examples and a real-world example are provided to demonstrate the practicality of the study results. In this study, a digital magnetic suspension system model was developed and reviewed. In addition, equivalent state and output feedback controls for magnetic suspension systems were developed. Using this method, the controller design for magnetic suspension systems was simplified, which is the novel contribution of this study. In addition, this paper proposes a complete digital controller design procedure for magnetic suspension systems.

  11. Characterization of the ELIMED prototype permanent magnet quadrupole system

    Science.gov (United States)

    Russo, A. D.; Schillaci, F.; Pommarel, L.; Romano, F.; Amato, A.; Amico, A. G.; Calanna, A.; Cirrone, G. A. P.; Costa, M.; Cuttone, G.; Amato, C.; De Luca, G.; Flacco, F. A.; Gallo, G.; Giove, D.; Grmek, A.; La Rosa, G.; Leanza, R.; Maggiore, M.; Malka, V.; Milluzzo, G.; Petringa, G.; Pipek, J.; Scuderi, V.; Vauzour, B.; Zappalà, E.

    2017-01-01

    The system described in this work is meant to be a prototype of a more performing one that will be installed at ELI-Beamlines in Prague for the collection of ions produced after the interaction Laser-target, [1]. It has been realized by the researchers of INFN-LNS (Laboratori Nazionali del Sud of the Instituto Nazionale di Fisica Nucleare) and SIGMAPHI, a French company, using a system of Permanent Magnet Quadrupoles (PMQs), [2]. The final system that will be installed in Prague is designed for protons and carbons up to 60 MeV/u, around 10 times more than the energies involved in the present work. The prototype, shown in this work, has been tested in collaboration with the SAPHIR experimental facility group at LOA (Laboratoire d'Optique Appliqueé) in Paris using a 200 TW Ti:Sapphire laser system. The purpose of this work is to validate the design and the performances of this large and compact bore system and to characterize the beam produced after the interaction laser-target and its features. Moreover, the optics simulations have been compared with a real beam shape on a GAFChromic film. The procedure used during the experimental campaign and the most relevant results are reported here demonstrating a good agreement with the simulations and a good control on the beam optics.

  12. Hybrid system calibration for multidimensional magnetic particle imaging

    Science.gov (United States)

    von Gladiss, A.; Graeser, M.; Szwargulski, P.; Knopp, T.; Buzug, T. M.

    2017-05-01

    Magnetic particle imaging visualizes the spatial distribution of superparamagnetic nanoparticles. Because of its key features of excellent sensitivity, high temporal and spatial resolution and biocompatibility of the tracer material it can be used in multiple medical imaging applications. The common reconstruction technique for Lissajous-type trajectories uses a system matrix that has to be previously acquired in a time-consuming calibration scan, leading to long downtimes of the scanning device. In this work, the system matrix is determined by a hybrid approach. Using the hybrid system matrix for reconstruction, the calibration downtime of the scanning device can be neglected. Furthermore, the signal to noise ratio of the hybrid system matrix is much higher, since the size of the required nanoparticle sample can be chosen independently of the desired voxel size. As the signal to noise ratio influences the reconstruction process, the resulting images have better resolution and are less affected by artefacts. Additionally, a new approach is introduced to address the background signal in image reconstruction. The common technique of subtraction of the background signal is replaced by extending the system matrix with an entry that represents the background. It is shown that this approach reduces artefacts in the reconstructed images.

  13. Feasible utility scale superconducting magnetic energy storage system

    Science.gov (United States)

    Loyd, R. J.; Schoenung, S. M.; Nakamura, T.; Lieurance, D. W.; Hilal, M. A.; Rogers, J. D.; Purcell, J. R.; Hassenzahl, W. V.

    This paper presents the latest design features and estimated costs of a 5000 MWh/1000 MW Superconducting Magnetic Energy Storage (SMES) plant. SMES is proposed as a commercially viable technology for electric utility load leveling. The primary advantage of SMES over other electrical energy storage technologies is its high net roundtrip efficiency. Other features include rapid availability and low maintenance and operating costs. Economic comparisons are made with other energy storage options and with gas turbines. In a diurnal load leveling application, a superconducting coil can be charged from the utility grid during off-peak hours. The ac grid is connected to the dc magnetic coil through a power conversion system that includes an inverter/rectifier. Once charged, the superconducting coil conducts current, which supports an electromagnetic field, with virtually no losses. During hours of peak load, the stored energy is discharged to the grid by reversing the charging process. The principle of operation of a SMES unit is shown. For operation in the superconducting mode, the coil is maintained at extremely low temperature by immersion in a bath of liquid helium.

  14. Magnetic

    National Research Council Canada - National Science Library

    Essam Aboud; Nabil El-Masry; Atef Qaddah; Faisal Alqahtani; Mohammed R.H. Moufti

    2015-01-01

    .... A joint interpretation and inversion of gravity and magnetic data were used to estimate the thickness of the lava flows, delineate the subsurface structures of the study area, and estimate the depth...

  15. Expanded Equations for Torque and Force on a Cylindrical Permanent Magnet Core in a Large-Gap Magnetic Suspension System

    Science.gov (United States)

    Groom, Nelson J.

    1997-01-01

    The expanded equations for torque and force on a cylindrical permanent magnet core in a large-gap magnetic suspension system are presented. The core is assumed to be uniformly magnetized, and equations are developed for two orientations of the magnetization vector. One orientation is parallel to the axis of symmetry, and the other is perpendicular to this axis. Fields and gradients produced by suspension system electromagnets are assumed to be calculated at a point in inertial space which coincides with the origin of the core axis system in its initial alignment. Fields at a given point in the core are defined by expanding the fields produced at the origin as a Taylor series. The assumption is made that the fields can be adequately defined by expansion up to second-order terms. Examination of the expanded equations for the case where the magnetization vector is perpendicular to the axis of symmetry reveals that some of the second-order gradient terms provide a method of generating torque about the axis of magnetization and therefore provide the ability to produce six-degree-of-freedom control.

  16. Asymmetry of the Hall Conductance Fluctuations in a Random Magnetic Field

    Science.gov (United States)

    1998-06-01

    and CNRS-LCMI, F-38042, Grenoble, France § Paul Scherrer Institute, CH-5232 Villigen-PSI, Switzerland ¶ Instituto de Fisica de Sao Carlos, 13560-970...samples (2 × 2 /•m×/zm) with a dimpled 2 DEG. This type of structures provides an experimental alternative for studying a spatially varying magnetic field...height of the dimples 0.1 Itm, which agrees well the experimental observations. The Hall resistance together with B-linear background reveals

  17. A Solution Method for Linear and Geometrically Nonlinear MDOF Systems with Random Properties subject to Random Excitation

    DEFF Research Database (Denmark)

    Micaletti, R. C.; Cakmak, A. S.; Nielsen, Søren R. K.

    structural properties. The resulting state-space formulation is a system of ordinary stochastic differential equations with random coefficient and deterministic initial conditions which are subsequently transformed into ordinary stochastic differential equations with deterministic coefficients and random...... initial conditions. This transformation facilitates the derivation of differential equations which govern the evolution of the unconditional statistical moments of response. Primary consideration is given to linear systems and systems with odd polynomial nonlinearities, for in these cases...... there is a significant reduction in the number of equations to be solved. The method is illustrated for a five-story shear-frame structure with nonlinear interstory restoring forces and random damping and stiffness properties. The results of the proposed method are compared to those estimated by extensive Monte Carlo...

  18. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  19. The Conceptual Design of a Magnetic Tape Seal System.

    Science.gov (United States)

    1981-01-22

    for fuel trmns- channel, pipe, *et. smitors; port; flow indics- portal mni- tors for on-load tors reactors, repro- cesing plants Integral Observe...A group of n succesive random digits forms what is known as an n-digit random number( 38 ) . Pseudo-random numbers (PRN) are random numbers generated

  20. Tunable biasing magnetic field design of ferrite tuner for ICRF heating system in EAST

    Science.gov (United States)

    Manman, XU; Yuntao, SONG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Guang, LIU; Zhen, PENG

    2017-11-01

    Ion cyclotron range of frequency (ICRF) heating has been used in tokamaks as one of the most successful auxiliary heating tools and has been adopted in the EAST. However, the antenna load will fluctuate with the change of plasma parameters in the ICRF heating process. To ensure the steady operation of the ICRF heating system in the EAST, fast ferrite tuner (FFT) has been carried out to achieve real-time impedance matching. For the requirements of the FFT impedance matching system, the magnet system of the ferrite tuner (FT) was designed by numerical simulations and experimental analysis, where the biasing magnetic circuit and alternating magnetic circuit were the key researched parts of the ferrite magnet. The integral design goal of the FT magnetic circuit is that DC bias magnetic field is 2000 Gs and alternating magnetic field is ±400 Gs. In the FTT, E-type magnetic circuit was adopted. Ferrite material is NdFeB with a thickness of 30 mm by setting the working point of NdFeB, and the ampere turn of excitation coil is 25 through the theoretical calculation and simulation analysis. The coil inductance to generate alternating magnetic field is about 7 mH. Eddy-current effect has been analyzed, while the magnetic field distribution has been measured by a Hall probe in the medium plane of the biasing magnet. Finally, the test results show the good performance of the biasing magnet satisfying the design and operating requirements of the FFT.

  1. Using fiberglass volumes for VPI of superconductive magnetic systems' insulation

    Science.gov (United States)

    Andreev, I. S.; Bezrukov, A. A.; Bursikov, A. S.; Klimchenko, Y. A.; Marushin, E. L.; Mednikov, A. A.; Pischugin, A. B.; Rodin, I. Y.; Stepanov, D. B.

    2014-01-01

    The paper describes the method of manufacturing fiberglass molds for vacuum pressure impregnation (VPI) of high-voltage insulation of superconductive magnetic systems (SMS) with epoxidian hot-setting compounds. The basic advantages of using such vacuum volumes are improved quality of insulation impregnation in complex-shaped areas, and considerable cost-saving of preparing VPI of large-sized components due to dispensing with the stage of fabricating a metal impregnating volume. Such fiberglass vacuum molds were used for VPI of high-voltage insulation samples of an ITER reactor's PF1 poloidal coil. Electric insulation of these samples has successfully undergone a wide range of high-voltage and mechanical tests at room and cryogenic temperatures. Some results of the tests are also given in this paper.

  2. A LabVIEW based cyclotron magnetic field mapping system

    Energy Technology Data Exchange (ETDEWEB)

    Marti, F.; Johnson, P. [NSCL, Michigan State University, East Lansing, MI (United States)

    1999-07-01

    This paper describes the application of National Instruments LabVIEW to the NSCL K500 magnet mapping, as part of the Coupled Cyclotron Upgrade. LabVIEW provides a fast development environment for hardware control from a PC running Windows NT. The PC and LabVIEW environment allow non-professional computer programmers to obtain a reliable and flexible system where modifications can be quickly implemented. This program supports the use of motor controllers, data acquisition cards, digital I/O modules and GPIB instruments. A complete map of 360 degrees is obtained in approximately 90 minutes, measuring 185000 field values with a spacing of 1.6 mm in radius every degree. (author)

  3. Central nervous system lymphoma: magnetic resonance imaging features at presentation

    Directory of Open Access Journals (Sweden)

    Ricardo Schwingel

    2012-02-01

    Full Text Available OBJECTIVE: This paper aimed at studying presentations of the central nervous system (CNS lymphoma using structural images obtained by magnetic resonance imaging (MRI. METHODS: The MRI features at presentation of 15 patients diagnosed with CNS lymphoma in a university hospital, between January 1999 and March 2011, were analyzed by frequency and cross tabulation. RESULTS: All patients had supratentorial lesions; and four had infra- and supratentorial lesions. The signal intensity on T1 and T2 weighted images was predominantly hypo- or isointense. In the T2 weighted images, single lesions were associated with a hypointense signal component. Six patients presented necrosis, all of them showed perilesional abnormal white matter, nine had meningeal involvement, and five had subependymal spread. Subependymal spread and meningeal involvement tended to occur in younger patients. CONCLUSION: Presentations of lymphoma are very pleomorphic, but some of them should point to this diagnostic possibility.

  4. SPIN POLARIZED PHOTOELECTRON SPECTROSCOPY AS A PROBE OF MAGNETIC SYSTEMS.

    Energy Technology Data Exchange (ETDEWEB)

    JOHNSON, P.D.; GUNTHERODT, G.

    2006-11-01

    Spin-polarized photoelectron spectroscopy has developed into a versatile tool for the study of surface and thin film magnetism. In this chapter, we examine the methodology of the technique and its recent application to a number of different problems. We first examine the photoemission process itself followed by a detailed review of spin-polarization measurement techniques and the related experimental requirements. We review studies of spin polarized surface states, interface states and quantum well states followed by studies of the technologically important oxide systems including half-metallic transition metal oxides, ferromagnet/oxide interfaces and the antiferromagnetic cuprates that exhibit high Tc Superconductivity. We also discuss the application of high-resolution photoemission with spin resolving capabilities to the study of spin dependent self energy effects.

  5. Nanometer-size magnetic domains and coherent magnetization reversal in a giant exchange-bias system

    DEFF Research Database (Denmark)

    Dufour, C.; Fitzsimmons, M. R.; Borchers, J. A.

    2011-01-01

    The role of magnetic domains and domain walls in exchange bias has stimulated much contemporary deliberation. Here we present compelling evidence obtained with small-angle scattering of unpolarized- and polarized-neutron beams that magnetization reversal occurs via formation of 10-100s nm......-sized magnetic domains in an exchange-biased DyFe2/YFe2 superlattice. The reversal mechanism is observed to involve rotation of magnetization in and out of the sample plane. Remarkably, the domains are arranged in a quasiperiodic manner in the plane of the sample. The length scale of domain formation is similar...

  6. Development of a triplet magnetic lens system to focus a pulsed neutron beam

    Energy Technology Data Exchange (ETDEWEB)

    Oku, Takayuki; Kira, Hiroshi; Shinohara, Takenao; Takata, Shin-ichi; Arai, Masatoshi; Suzuki, Jun-ichi; Shimizu, Hirohiko M, E-mail: oku.takayuki@jaea.go.jp

    2010-11-01

    A triplet magnetic lens system composed of three sextupole-magnets and two spin flippers was constructed to focus pulsed neutrons in a wide wavelength range with same focal lengths. In this study, we performed a pulsed neutron beam focusing experiment with the system. The design of the system and the experimental results are shown and discussed.

  7. Randomly Sampled-Data Control Systems. Ph.D. Thesis

    Science.gov (United States)

    Han, Kuoruey

    1990-01-01

    The purpose is to solve the Linear Quadratic Regulator (LQR) problem with random time sampling. Such a sampling scheme may arise from imperfect instrumentation as in the case of sampling jitter. It can also model the stochastic information exchange among decentralized controllers to name just a few. A practical suboptimal controller is proposed with the nice property of mean square stability. The proposed controller is suboptimal in the sense that the control structure is limited to be linear. Because of i. i. d. assumption, this does not seem unreasonable. Once the control structure is fixed, the stochastic discrete optimal control problem is transformed into an equivalent deterministic optimal control problem with dynamics described by the matrix difference equation. The N-horizon control problem is solved using the Lagrange's multiplier method. The infinite horizon control problem is formulated as a classical minimization problem. Assuming existence of solution to the minimization problem, the total system is shown to be mean square stable under certain observability conditions. Computer simulations are performed to illustrate these conditions.

  8. Low temperature superconductor and aligned high temperature superconductor magnetic dipole system and method for producing high magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Ramesh; Scanlan, Ronald; Ghosh, Arup K.; Weggel, Robert J.; Palmer, Robert; Anerella, Michael D.; Schmalzle, Jesse

    2017-10-17

    A dipole-magnet system and method for producing high-magnetic-fields, including an open-region located in a radially-central-region to allow particle-beam transport and other uses, low-temperature-superconducting-coils comprised of low-temperature-superconducting-wire located in radially-outward-regions to generate high magnetic-fields, high-temperature-superconducting-coils comprised of high-temperature-superconducting-tape located in radially-inward-regions to generate even higher magnetic-fields and to reduce erroneous fields, support-structures to support the coils against large Lorentz-forces, a liquid-helium-system to cool the coils, and electrical-contacts to allow electric-current into and out of the coils. The high-temperature-superconducting-tape may be comprised of bismuth-strontium-calcium-copper-oxide or rare-earth-metal, barium-copper-oxide (ReBCO) where the rare-earth-metal may be yttrium, samarium, neodymium, or gadolinium. Advantageously, alignment of the large-dimension of the rectangular-cross-section or curved-cross-section of the high-temperature-superconducting-tape with the high-magnetic-field minimizes unwanted erroneous magnetic fields. Alignment may be accomplished by proper positioning, tilting the high-temperature-superconducting-coils, forming the high-temperature-superconducting-coils into a curved-cross-section, placing nonconducting wedge-shaped-material between windings, placing nonconducting curved-and-wedge-shaped-material between windings, or by a combination of these techniques.

  9. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  10. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  11. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  12. Development of a hybrid magnetic resonance and ultrasound imaging system.

    Science.gov (United States)

    Sherwood, Victoria; Civale, John; Rivens, Ian; Collins, David J; Leach, Martin O; ter Haar, Gail R

    2014-01-01

    A system which allows magnetic resonance (MR) and ultrasound (US) image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1-4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR) as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

  13. Development of a Hybrid Magnetic Resonance and Ultrasound Imaging System

    Directory of Open Access Journals (Sweden)

    Victoria Sherwood

    2014-01-01

    Full Text Available A system which allows magnetic resonance (MR and ultrasound (US image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1–4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

  14. Magnetocardiography System in Open-door Magnetically-shielded Room

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. M.; Lee, Y. H.; Kwon, H.; Yu, K. K.; Kim, K.; Park, Y. K. [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Sasada, I. [Kyushu University, Fukuoka (Japan)

    2007-10-15

    We have installed a 61-channel magnetocardiography (MCG) system inside a magnetically shielded room (MSR) with a size of 24 m x 24 m x 24 m. The MCG system consists of 1st-order axial gradiometers containing double relaxation oscillation SQUIDs (DROSs) with pick-up coils of a base line of 70 mm. The MSR holds a shielding factor of 50 at 0.1 Hz and 10000 at 100 Hz, when its door in the middle on a front wall is closed. On opening the MSR door, we have obtained the characteristics of the MCG system with a 2.9 Hz noise generated from an air conditioning unit at 13 m distance off the MSR. In an open-door MSR (140 degrees opening), a noise at the center channel increases up to 700 fT/Hz{sup 1/2} at 2.9 Hz and 1.7fT/Hz{sup 1/2} at 60 Hz. MCG signals for a healthy human do not show distortion until the door opens to 45 degrees, but show the effect of noise when the door opens further at 90 degrees and 140 degrees. With the door opens to 45 degrees, MCG measurement can be performed with ease of door operation and without creating claustrophobia for the patient.

  15. Commissioning of the LHC Magnet Powering System in 2009

    CERN Document Server

    Solfaroli Camillocci, Matteo; Bellesia, Boris; Coupard, Julie; Dahlerup-Petersen, Knud; Koratzinos, Michael; Pojer, Mirko; Schmidt, Ruediger; Siemko, Andrzej; Thiesen, Hugues; Vergara-Fernandez, Antonio; Zanetti, Marco; Zerlauth, Markus

    2010-01-01

    On 19th September 2008 the Large Hadron Collider (LHC) experienced a serious incident, caused by a defective electrical joint, which stopped beam operation just a few days after its beginning. During the following 14 months the damage was repaired, additional protection systems were installed and the measures to avoid a similar incident were taken, i.e. new layer of the Magnet Quench Protection System (nQPS) and more efficient He release valves. As a consequence, a large number of powering tests had to be repeated or carried out for the first time. The re-commissioning of the already existing systems as well as the commissioning of the new ones was carefully studied, then performed taking into account the history of each of the eight LHC sectors (either warmed-up or left at floating temperature). Moreover, a campaign of measurements of the bus-bar splice resistances as well as the ones internal to the cold masses was carried out with the original and the nQPS in order to spot out non conformities, thus assess...

  16. Reduction of Claustrophobia with Short-Bore versus Open Magnetic Resonance Imaging: A Randomized Controlled Trial

    OpenAIRE

    Enders, Judith; Zimmermann, Elke; Rief, Matthias; Martus, Peter; Klingebiel, Randolf; Asbach, Patrick; Klessen, Christian; Diederichs, Gerd; Wagner, Moritz; Teichgräber, Ulf; Bengner, Thomas; Hamm, Bernd; Dewey, Marc

    2011-01-01

    Background Claustrophobia is a common problem precluding MR imaging. The purpose of the present study was to assess whether a short-bore or an open magnetic resonance (MR) scanner is superior in alleviating claustrophobia. Methods Institutional review board approval and patient informed consent were obtained to compare short-bore versus open MR. From June 2008 to August 2009, 174 patients (139 women; mean age = 53.1 [SD 12.8]) with an overall mean score of 2.4 (SD 0.7, range 0 to 4) on the Cl...

  17. The magnetostriction in a superconductor-magnet system under non-uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xueyi; Jiang, Lang; Wu, Hao [Key Laboratory of Mechanics on Disaster and Environment in Western China attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000 (China); Gao, Zhiwen, E-mail: gaozhw@lzu.edu.cn [Department of Mechanics and Engineering Science, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2017-03-15

    Highlights: • We studied firstly magnetostriction in HTS under non-uniform magnetic field. • The superconductors may be homogeneous and nonhomogeneous. • The magnetostrictions response of the HTS is sensitive to the critical current density and amplitude of the applied magnetic field. • The magnetostriction of nonhomogeneous HTS is larger than that of homogeneous HTS. - Abstract: This paper describes a numerical model to examine the magnetostriction of bulk high-temperature superconductor (HTS) under non-uniform magnetic field in conjunction with finite element analysis. Through this model, the magnetostriction of homogeneous and nonhomogeneous HTS can be implemented under non-uniform magnetic field. Further, the effects of critical current density, applied field frequency and amplitude are also considered. The computational study can provide a fundamental mechanistic understanding the effects of non-uniform magnetic field on magnetostriction of HTS.

  18. Complete Many-Body Localization in the t-J Model Caused by a Random Magnetic Field.

    Science.gov (United States)

    Lemut, Gal; Mierzejewski, Marcin; Bonča, Janez

    2017-12-15

    The many body localization (MBL) of spin-1/2 fermions poses a challenging problem. It is known that the disorder in the charge sector may be insufficient to cause full MBL. Here, we study dynamics of a single hole in one dimensional t-J model subject to a random magnetic field. We show that strong disorder that couples only to the spin sector localizes both spin and charge degrees of freedom. Charge localization is confirmed also for a finite concentration of holes. While we cannot precisely pinpoint the threshold disorder, we conjecture that there are two distinct transitions. Weaker disorder first causes localization in the spin sector. Carriers become localized for somewhat stronger disorder, when the spin localization length is of the order of a single lattice spacing.

  19. Computed tomography synthesis from magnetic resonance images in the pelvis using multiple random forests and auto-context features

    DEFF Research Database (Denmark)

    Andreasen, Daniel; Morgenthaler Edmund, Jens; Zografos, Vasileios

    2016-01-01

    In radiotherapy treatment planning that is only based on magnetic resonance imaging (MRI), the electron density information usually obtained from computed tomography (CT) must be derived from the MRI by synthesizing a so-called pseudo CT (pCT). This is a non-trivial task since MRI intensities...... are neither uniquely nor quantitatively related to electron density. Typical approaches involve either a classification or regression model requiring specialized MRI sequences to solve intensity ambiguities, or an atlas-based model necessitating multiple registrations between atlases and subject scans....... In this work, we explore a machine learning approach for creating a pCT of the pelvic region from conventional MRI sequences without using atlases. We use a random forest provided with information about local texture, edges and spatial features derived from the MRI. This helps to solve intensity ambiguities...

  20. Dissipative random quantum spin chain with boundary-driving and bulk-dephasing: magnetization and current statistics in the non-equilibrium-steady-state

    Science.gov (United States)

    Monthus, Cécile

    2017-04-01

    The Lindblad dynamics with dephasing in the bulk and magnetization-driving at the two boundaries is studied for the quantum spin chain with random fields h j and couplings J j (that can be either uniform or random). In the regime of strong disorder in the random fields, or in the regime of strong bulk-dephasing, the effective dynamics can be mapped onto a classical simple symmetric exclusion process with quenched disorder in the diffusion coefficient associated to each bond. The properties of the corresponding non-equilibrium-steady-state in each disordered sample between the two reservoirs are studied in detail by extending the methods that have been previously developed for the symmetric exclusion process without disorder. Explicit results are given for the magnetization profile, for the two-point correlations, for the mean current and for the current fluctuations, in terms of the random fields and couplings defining the disordered sample.

  1. Ordering and phase transitions in random-field Ising systems

    Science.gov (United States)

    Maritan, Amos; Swift, Michael R.; Cieplak, Marek; Chan, Moses H. W.; Cole, Milton W.; Banavar, Jayanth R.

    1991-01-01

    An exact analysis of the Ising model with infinite-range interactions in a random field and a local mean-field theory in three dimensions is carried out leading to a phase diagram with several coexistence surfaces and lines of critical points. The results show that the phase diagram depends crucially on whether the distribution of random fields is symmetric or not. Thus, Ising-like phase transitions in a porous medium (the asymmetric case) are in a different universality class from the conventional random-field model (symmetric case).

  2. Realization of the thermal equilibrium in inhomogeneous magnetic systems by the Landau-Lifshitz-Gilbert equation with stochastic noise, and its dynamical aspects

    Science.gov (United States)

    Nishino, Masamichi; Miyashita, Seiji

    2015-04-01

    It is crucially important to investigate the effects of temperature on magnetic properties such as critical phenomena, nucleation, pinning, domain wall motion, and coercivity. The Landau-Lifshitz-Gilbert (LLG) equation has been applied extensively to study dynamics of magnetic properties. Approaches of Langevin noises have been developed to introduce the temperature effect into the LLG equation. To have the thermal equilibrium state (canonical distribution) as the steady state, the system parameters must satisfy some condition known as the fluctuation-dissipation relation. In inhomogeneous magnetic systems in which spin magnitudes are different at sites, the condition requires that the ratio between the amplitude of the random noise and the damping parameter depend on the magnitude of the magnetic moment at each site. Focused on inhomogeneous magnetic systems, we systematically showed agreement between the stationary state of the stochastic LLG equation and the corresponding equilibrium state obtained by Monte Carlo simulations in various magnetic systems including dipole-dipole interactions. We demonstrated how violations of the condition result in deviations from the true equilibrium state. We also studied the characteristic features of the dynamics depending on the choice of the parameter set. All the parameter sets satisfying the condition realize the same stationary state (equilibrium state). In contrast, different choices of parameter set cause seriously different relaxation processes. We show two relaxation types, i.e., magnetization reversals with uniform rotation and with nucleation.

  3. Direct measurement of the impulse in a magnetic thrust chamber system for laser fusion rocket

    Energy Technology Data Exchange (ETDEWEB)

    Maeno, Akihiro; Yamamoto, Naoji; Nakashima, Hideki [Interdisciplinary Graduate School of Engineering Science, Kyushu University, 6-1 Kasuga-kouen, Kasuga, Fukuoka 816-8580 (Japan); Fujioka, Shinsuke; Johzaki, Tomoyuki [Institute of Laser Engineering, Osaka University, Suita, Osaka 565-087 (Japan); Mori, Yoshitaka [Graduate School for the Creation of New Photonics Industries, Hamamatsu, Shizuoka 431-1202 (Japan); Sunahara, Atsushi [Institute for Laser Technology, Suita, Osaka 565-087 (Japan)

    2011-08-15

    An experiment is conducted to measure an impulse for demonstrating a magnetic thrust chamber system for laser fusion rocket. The impulse is produced by the interaction between plasma and magnetic field. In the experiment, the system consists of plasma and neodymium permanent magnets. The plasma is created by a single-beam laser aiming at a polystyrene spherical target. The impulse is 1.5 to 2.2 {mu}Ns by means of a pendulum thrust stand, when the laser energy is 0.7 J. Without magnetic field, the measured impulse is found to be zero. These results indicate that the system for generating impulse is working.

  4. System Cost Analysis for an Interior Permanent Magnet Motor

    Energy Technology Data Exchange (ETDEWEB)

    Peter Campbell

    2008-08-01

    The objective of this program is to provide an assessment of the cost structure for an interior permanent magnet ('IPM') motor which is designed to meet the 2010 FreedomCAR specification. The program is to evaluate the range of viable permanent magnet materials for an IPM motor, including sintered and bonded grades of rare earth magnets. The study considers the benefits of key processing steps, alternative magnet shapes and their assembly methods into the rotor (including magnetization), and any mechanical stress or temperature limits. The motor's costs are estimated for an annual production quantity of 200,000 units, and are broken out into such major components as magnetic raw materials, processing and manufacturing. But this is essentially a feasibility study of the motor's electromagnetic design, and is not intended to include mechanical or thermal studies as would be done to work up a selected design for production.

  5. Large deviations of the finite-time magnetization of the Curie-Weiss random-field Ising model.

    Science.gov (United States)

    Paga, Pierre; Kühn, Reimer

    2017-08-01

    We study the large deviations of the magnetization at some finite time in the Curie-Weiss random field Ising model with parallel updating. While relaxation dynamics in an infinite-time horizon gives rise to unique dynamical trajectories [specified by initial conditions and governed by first-order dynamics of the form m_{t+1}=f(m_{t})], we observe that the introduction of a finite-time horizon and the specification of terminal conditions can generate a host of metastable solutions obeying second-order dynamics. We show that these solutions are governed by a Newtonian-like dynamics in discrete time which permits solutions in terms of both the first-order relaxation ("forward") dynamics and the backward dynamics m_{t+1}=f^{-1}(m_{t}). Our approach allows us to classify trajectories for a given final magnetization as stable or metastable according to the value of the rate function associated with them. We find that in analogy to the Freidlin-Wentzell description of the stochastic dynamics of escape from metastable states, the dominant trajectories may switch between the two types (forward and backward) of first-order dynamics. Additionally, we show how to compute rate functions when uncertainty in the quenched disorder is introduced.

  6. Comparison between intranasal dexmedetomidine and intranasal midazolam as premedication for brain magnetic resonance imaging in pediatric patients: A prospective randomized double blind trial

    OpenAIRE

    Ayushi Gupta,; Naina Parag Dalvi; Bharati Anil Tendolkar

    2017-01-01

    Background and Aims: Preprocedural preparation of children scheduled for magnetic resonance imaging (MRI) is challenging. This prospective, randomized trial compared intranasal midazolam with intranasal dexmedetomidine as premedication for children scheduled for brain MRI. Material and Methods: In total, 60 children, aged 1?8 years, scheduled for elective brain MRI, were randomly assigned to the intranasal dexmedetomidine (1 ?g/kg; Group D) or intranasal midazolam (0.2 mg/kg; Group M) group. ...

  7. Static magnetic field reduced exogenous oligonucleotide uptake by spermatozoa using magnetic nanoparticle gene delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Katebi, Samira; Esmaeili, Abolghasem, E-mail: aesmaeili@sci.ui.ac.ir; Ghaedi, Kamran

    2016-03-15

    Spermatozoa could introduce exogenous oligonucleotides of interest to the oocyte. The most important reason of low efficiency of sperm mediated gene transfer (SMGT) is low uptake of exogenous DNA by spermatozoa. The aim of this study was to evaluate the effects of static magnetic field on exogenous oligonucleotide uptake of spermatozoa using magnetofection method. Magnetic nanoparticles (MNPs) associated with the labeled oligonucleotides were used to increase the efficiency of exogenous oligonucleotide uptake by rooster spermatozoa. We used high-field/high-gradient magnet (NdFeB) to enhance and accelerate exogenous DNA sedimentation at the spermatozoa surface. Flow cytometry analysis was performed to measure viability and percentage of exogenous oligonucleotide uptake by sperm. Flow cytometry analysis showed a significant increase in exogenous oligonucleotide uptake by rooster spermatozoa (P<0.001) when spermatozoa were incubated in exogenous oligonucleotide solution and MNPs. However, by applying static magnetic field during magnetofection method, a significant decrease in exogenous oligonucleotide uptake was observed (P<0.05). Findings of this study showed that MNPs were effective to increase exogenous oligonucleotide uptake by rooster spermatozoa; however unlike others studies, static magnetic field, was not only ineffective to enhance exogenous oligonucleotide uptake by rooster spermatozoa but also led to reduction in efficiency of magnetic nanoparticles in gene transfer. - Highlights: • Core/shell type Iron oxide nanoparticles were used as a novel and efficient method. • This method increases exogenous DNA uptake by rooster spermatozoa. • Static magnetic field decreased DNA uptake by rooster spermatozoa.

  8. Finitely connected vector spin systems with random matrix interactions

    Energy Technology Data Exchange (ETDEWEB)

    Coolen, A C C [Department of Mathematics, King' s College London, The Strand, London WC2R 2LS (United Kingdom); Skantzos, N S [Institute for Theoretical Physics, Celestijnenlaan 200D, Katholieke Universiteit Leuven, B-3001 (Belgium); Castillo, I Perez [Rudolf Peierls Center for Theoretical Physics, University of Oxford, 1 Keble Road, Oxford, OX1 3NP (United Kingdom); Vicente, C J Perez [Departament de FIsica Fonamental, Facultat de FIsica, Universitat de Barcelona, 08028 Barcelona (Spain); Hatchett, J P L [Laboratory for Mathematical Neuroscience, RIKEN Brain Science Institute, Hirosawa 2-1, Wako-Shi, Saitama 351-0198 (Japan); Wemmenhove, B [Department of Medical Physics and Biophysics, Radboud University Nijmegen, Geert Grooteplein 21, NL 6525 EZ Nijmegen (Netherlands); Nikoletopoulos, T [Department of Mathematics, King' s College London, The Strand, London WC2R 2LS (United Kingdom)

    2005-09-30

    We use finite connectivity equilibrium replica theory to solve models of finitely connected unit-length vectorial spins, with random pair-interactions which are of the orthogonal matrix type. Finitely connected spin models, although still of a mean-field nature, can be regarded as a convenient level of description in between fully connected and finite-dimensional ones. Since the spins are continuous and the connectivity c remains finite in the thermodynamic limit, the replica-symmetric order parameter is a functional. The general theory is developed for arbitrary values of the dimension d of the spins, and arbitrary choices of the ensemble of random orthogonal matrices. We calculate phase diagrams and the values of moments of the order parameter explicitly for d = 2 (finitely connected XY spins with random chiral interactions) and for d = 3 (finitely connected classical Heisenberg spins with random chiral interactions). Numerical simulations are shown to support our predictions quite satisfactorily.

  9. Analytical and computational study of magnetization switching in kinetic Ising systems with demagnetizing fields

    DEFF Research Database (Denmark)

    Richards, H.L.; Rikvold, P.A.

    1996-01-01

    . For systems in the weak-field ''stochastic region,'' where magnetization switching is on average effected by the nucleation and growth of a single droplet, the simulation results can be explained by a simple model in which the free energy is a function only of magnetization. In the intermediate......-field ''multidroplet region,'' a generalization of Avrami's law involving a magnetization-dependent effective magnetic field gives good agreement with the simulations. The effects of the demagnetizing field do not qualitatively change the droplet-theoretical picture of magnetization switching in highly anisotropic...

  10. Globally Optimal Segmentation of Permanent-Magnet Systems

    DEFF Research Database (Denmark)

    Insinga, Andrea Roberto; Bjørk, Rasmus; Smith, Anders

    2016-01-01

    functional that is linear in the magnetic field. This approach, however, yields a continuously varying remanent flux density, while in practical applications, magnetic assemblies are realized by combining uniformly magnetized segments. The problem of determining the optimal shape of each of these segments...... remains unsolved. We show that the problem of optimal segmentation of a two-dimensional permanent-magnet assembly with respect to a linear objective functional can be reduced to the problem of piecewise linear approximation of a plane curve by perimeter maximization. Once the problem has been cast...

  11. Magnetic nanoparticles as targeted delivery systems in oncology

    National Research Council Canada - National Science Library

    Prijic, Sara; Sersa, Gregor

    2011-01-01

    Background. Many different types of nanoparticles, magnetic nanoparticles being just a category among them, offer exciting opportunities for technologies at the interfaces between chemistry, physics and biology...

  12. Magnetically-Actuated Escherichia coli System for Micro Lithography

    Science.gov (United States)

    Lauback, S.; Brown, E.; Pérez-Guzman, L.; Peace, C.; Pierce, C.; Lower, B. H.; Lower, S. K.; Sooryakumar, R.

    2015-03-01

    Technologies that control matter at the nano- and micro-scale are crucial for developing new engineered materials and devices. While the more traditional approaches for such manipulations often depend on lithographic fabrication, they can be expanded upon by taking advantage of the biological systems within a living cell which also operate on the nano- and micro- scale. In this study, a system is being developed to functionalize a targeted location on the surface of a chip with the protein AmCyan from transformed Escherichia coli cells. Using established methods in molecular biology where a plasmid with the amcyan gene sequence is inserted into the cell, E. coli are engineered to express the AmCyan protein on their outer surface. In order to transport the cells to the targeted location, the transformed E. coli are labeled with superparamagnetic micro-beads which exert directed forces on the cells in an external field. Preliminary results of the protein expression on E. coli, the transport of the cell through weak magnetic fields to targeted locations and the potential to transfer protein from the cell to the chip surface will be presented.

  13. Annual Conference on Magnetism and Magnetic Materials, 29th, Pittsburgh, PA, November 8-11, 1983, Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, R.; Koon, N.C.; Cooper, B.R.

    1984-03-15

    Various topics on magnetism and magnetic materials are addressed. The subjects considered include: spin glasses, amorphous magnetism, actinide and rare earth intermetallics, magnetic excitation, itinerant magnetism and magnetic structure, valence instabilities, Kondo effect, transport and Hall effects, mixed valence and Kondo compounds, superconductivity and magnetism, d and f electron magnetism and superconductivity, Fe-based microcrystalline and permanent magnetic alloys, hard and soft magnetic materials, and magnetooptics. Also discussed are: numerical methods for magnetic field computation, recording theory and experiments, recording heads and media, magnetic studies via hyperfine interactions, magnetic semiconductors, magnet insulators, transition metal systems, random fields, critical phenomena and magnetoelastic effects and resonance, surfaces and interfaces, magnetostatic waves and resonance, bubble materials and implantation, bubble devices and physics, magnetic separation, ferrofluids, magnetochemistry, new techniques and materials, and new applications.

  14. Annual Conference on Magnetism and Magnetic Materials, 29th, Pittsburgh, PA, November 8-11, 1983, Proceedings

    Science.gov (United States)

    Hasegawa, R.; Koon, N. C.; Cooper, B. R.

    1984-03-01

    Various topics on magnetism and magnetic materials are addressed. The subjects considered include: spin glasses, amorphous magnetism, actinide and rare earth intermetallics, magnetic excitation, itinerant magnetism and magnetic structure, valence instabilities, Kondo effect, transport and Hall effects, mixed valence and Kondo compounds, superconductivity and magnetism, d and f electron magnetism and superconductivity, Fe-based microcrystalline and permanent magnetic alloys, hard and soft magnetic materials, and magnetooptics. Also discussed are: numerical methods for magnetic field computation, recording theory and experiments, recording heads and media, magnetic studies via hyperfine interactions, magnetic semiconductors, magnet insulators, transition metal systems, random fields, critical phenomena and magnetoelastic effects and resonance, surfaces and interfaces, magnetostatic waves and resonance, bubble materials and implantation, bubble devices and physics, magnetic separation, ferrofluids, magnetochemistry, new techniques and materials, and new applications. For individual items see A84-27016 to A84-27043

  15. High Field In vivo13C Magnetic Resonance Spectroscopy of Brain by Random Radiofrequency Heteronuclear Decoupling and Data Undersampling

    Directory of Open Access Journals (Sweden)

    Ningzhi Li

    2017-06-01

    Full Text Available In vivo13C magnetic resonance spectroscopy (MRS is a unique and effective tool for studying dynamic human brain metabolism and the cycling of neurotransmitters. One of the major technical challenges for in vivo13C-MRS is the high radio frequency (RF power necessary for heteronuclear decoupling. In the common practice of in vivo13C-MRS, alkanyl carbons are detected in the spectra range of 10–65 ppm. The amplitude of decoupling pulses has to be significantly greater than the large one-bond 1H-13C scalar coupling (1JCH = 125–145 Hz. Two main proton decoupling methods have been developed: broadband stochastic decoupling and coherent composite or adiabatic pulse decoupling (e.g., WALTZ; the latter is widely used because of its efficiency and superb performance under inhomogeneous B1 field. Because the RF power required for proton decoupling increases quadratically with field strength, in vivo13C-MRS using coherent decoupling is often limited to low magnetic fields [<=4 Tesla (T] to keep the local and averaged specific absorption rate (SAR under the safety guidelines established by the International Electrotechnical Commission (IEC and the US Food and Drug Administration (FDA. Alternately, carboxylic/amide carbons are coupled to protons via weak long-range 1H-13C scalar couplings, which can be decoupled using low RF power broadband stochastic decoupling. Recently, the carboxylic/amide 13C-MRS technique using low power random RF heteronuclear decoupling was safely applied to human brain studies at 7T. Here, we review the two major decoupling methods and the carboxylic/amide 13C-MRS with low power decoupling strategy. Further decreases in RF power deposition by frequency-domain windowing and time-domain random under-sampling are also discussed. Low RF power decoupling opens the possibility of performing in vivo13C experiments of human brain at very high magnetic fields (such as 11.7T, where signal-to-noise ratio as well as spatial and temporal

  16. Magnetic control of potential microrobotic drug delivery systems: nanoparticles, magnetotactic bacteria and self-propelled microjets

    NARCIS (Netherlands)

    Khalil, I.S.M.; Magdanz, V.; Sanchez, Stefan; Sanchez, S.; Schmidt, O.G.; Abelmann, Leon; Misra, Sarthak

    2013-01-01

    Development of targeted drug delivery systems using magnetic microrobots increases the therapeutic indices of drugs. These systems have to be incorporated with precise motion controllers. We demonstrate closed-loop motion control of microrobots under the influence of controlled magnetic fields.

  17. Finite-Time Chaos Control of a Complex Permanent Magnet Synchronous Motor System

    OpenAIRE

    Zhou, Xiaobing; Jiang, Murong; Cai, Xiaomei

    2014-01-01

    This paper investigates the finite-time chaos control of a permanent magnet synchronous motor system with complex variables. Based on the finite-time stability theory, two control strategies are proposed to realize stabilization of the complex permanent magnet synchronous motor system in a finite time. Two numerical simulations have been conducted to demonstrate the validity and feasibility of the theoretical analysis.

  18. Case study of a magnetic system for low-energy machines

    Directory of Open Access Journals (Sweden)

    Daniel Schoerling

    2016-08-01

    Full Text Available The extra low-energy antiproton ring (ELENA is a CERN particle decelerator with the purpose to deliver antiprotons at lowest energies aiming to enhance the study of antimatter. The hexagonal shaped ring with a circumference of about 30 m will decelerate antiprotons from momenta of 100 to 13.7  MeV/c. In this paper, the design approach for a magnet system for such a machine is presented. Due to the extra-low beam rigidity, the design of the magnet system is especially challenging because even small fields, arising for example from residual magnetization and hysteresis, have a major impact on beam dynamics. In total, seven prototype magnets of three different magnet types have been built and tested. This paper outlines challenges, describes solutions for the design of the magnet system and discusses the results of the prototypes.

  19. Public magnetic field exposure based on internal current density for electric low voltage systems.

    Science.gov (United States)

    Keikko, Tommi; Seesvuori, Reino; Hyvönen, Martti; Valkealahti, Seppo

    2009-04-01

    A measurement concept utilizing a new magnetic field exposure metering system has been developed for indoor substations where voltage is transformed from a medium voltage of 10 or 20 kV to a low voltage of 400 V. The new metering system follows the guidelines published by the International Commission on Non-Ionizing Radiation Protection. It can be used to measure magnetic field values, total harmonic distortion of the magnetic field, magnetic field exposure ratios for public and workers, load current values, and total harmonic distortion of the load current. This paper demonstrates how exposure to non-sinusoidal magnetic fields and magnetic flux density exposure values can be compared directly with limit values for internal current densities in a human body. Further, we present how the magnetic field and magnetic field exposure behaves in the vicinity of magnetic field sources within the indoor substation and in the neighborhood. Measured magnetic fields around the substation components have been used to develop a measurement concept by which long-term measurements in the substations were performed. Long-term measurements revealed interesting and partly unexpected dependencies between the measured quantities, which have been further analyzed. The principle of this paper is to substitute a demanding exposure measurement with measurements of the basic quantities like the 50 Hz fundamental magnetic field component, which can be estimated based on the load currents for certain classes of substation lay-out.

  20. Magnetic Materials: Novel Monitors of Long-Term Evolution of Engineered Barrier Systems

    Directory of Open Access Journals (Sweden)

    Simon L. Harley

    2016-12-01

    Full Text Available Most safety cases for the deep geological disposal of radioactive waste are reliant on the swelling of bentonite in the engineered barrier system as it saturates with groundwater. Assurance of safety therefore requires effective monitoring of bentonite saturation. The time- and fluid-dependent corrosion of synthetic magnets embedded in bentonite is demonstrated here to provide a novel and passive means of monitoring saturation. Experiments have been conducted at 70 °C in which neo magnets, AlNiCo magnets, and ferrite magnets have been reacted with saline (NaCl, KCl, CaCl2 solutions and alkaline fluids (NaOH, KOH, Ca(OH2 solutions; pH = 12 in the presence of bentonite. Nd-Fe-B magnets undergo extensive corrosion that results in a dramatic change from ferromagnetic to superparamagnetic behaviour concomitant with bentonite saturation. AlNiCo magnets in saline solutions show corrosion but only limited decreases in their magnetic intensities, and ferrite magnets are essentially unreactive on the experimental timescales, retaining their initial magnetic properties. For all magnets the impact of their corrosion on bentonite swelling is negligible; alteration of bentonite is essentially governed by the applied fluid composition. In principle, synthetic magnet arrays can, with further development, be designed and embedded in bentonite to monitor its fluid saturation without compromising the integrity of the engineered barrier system itself.

  1. Amplification of large scale magnetic fields in a decaying MHD system

    Science.gov (United States)

    Park, Kiwan

    2017-10-01

    Dynamo theory explains the amplification of magnetic fields in the conducting fluids (plasmas) driven by the continuous external energy. It is known that the nonhelical continuous kinetic or magnetic energy amplifies the small scale magnetic field; and the helical energy, the instability, or the shear with rotation effect amplifies the large scale magnetic field. However, recently it was reported that the decaying magnetic energy independent of helicity or instability could generate the large scale magnetic field. This phenomenon may look somewhat contradictory to the conventional dynamo theory. But it gives us some clues to the fundamental mechanism of energy transfer in the magnetized conducting fluids. It also implies that an ephemeral astrophysical event emitting the magnetic and kinetic energy can be a direct cause of the large scale magnetic field observed in space. As of now the exact physical mechanism is not yet understood in spite of several numerical results. The plasma motion coupled with a nearly conserved vector potential in the magnetohydrodynamic (MHD) system may transfer magnetic energy to the large scale. Also the intrinsic property of the scaling invariant MHD equation may decide the direction of energy transfer. In this paper we present the simulation results of inversely transferred helical and nonhelical energy in a decaying MHD system. We introduce a field structure model based on the MHD equation to show that the transfer of magnetic energy is essentially bidirectional depending on the plasma motion and initial energy distribution. And then we derive α coefficient algebraically in line with the field structure model to explain how the large scale magnetic field is induced by the helical energy in the system regardless of an external forcing source. And for the algebraic analysis of nonhelical magnetic energy, we use the eddy damped quasinormalized Markovian approximation to show the inverse transfer of magnetic energy.

  2. Magnetic resonance imaging in neuropsychiatric systemic lupus erythematosus: current state of the art and novel approaches.

    Science.gov (United States)

    Postal, M; Lapa, A Tamires; Reis, F; Rittner, L; Appenzeller, S

    2017-04-01

    Systemic lupus erythematosus is a chronic, inflammatory, immune-mediated disease affecting 0.1% of the general population. Neuropsychiatric manifestations in systemic lupus erythematosus have been more frequently recognized and reported in recent years, occurring in up to 75% of patients during the disease course. Magnetic resonance imaging is known to be a useful tool for the detection of structural brain abnormalities in neuropsychiatric systemic lupus erythematosus patients because of the excellent soft-tissue contrast observed with MRI and the ability to acquire multiplanar images. In addition to conventional magnetic resonance imaging techniques to evaluate the presence of atrophy and white matter lesions, several different magnetic resonance imaging techniques have been used to identify microstructural or functional abnormalities. This review will highlight different magnetic resonance imaging techniques, including the advanced magnetic resonance imaging methods used to determine central nervous system involvement in systemic lupus erythematosus.

  3. The standard Instrumentation Feedthrough System for the LHC cryo-magnets

    CERN Document Server

    Bozzini, D

    2002-01-01

    For the LHC, 1232 dipole magnets and about 400 quadrupole magnets operating at 1.9 K are installed in arcs and dispersion suppressors. Each cryo-magnet assembly comprises the main magnet and several small corrector magnets. Each assembly is equipped with voltage taps, quench heaters and cryogenic instrumentation. The number of instrumentation wires serving each magnet assembly and passing from cold to ambient is between 36 and 40. An Instrumentation Feedthrough System (IFS) will electrically and mechanically connect the instrument wires to the outside of the vacuum vessel. The IFS has to satisfy several requirements: simplicity of integration, optimal access during tests and commissioning, voltage withstand and reliability during the lifetime of the machine. The heat load to superfluid helium must be minimized, and the long-term stability of the insulation vacuum should be preserved. The solution foresees an open stainless steel tube housing the wires connected between the magnet and the outside of the vacuum...

  4. Development of rotating magnetic field system for the {beta}-NMR method

    Energy Technology Data Exchange (ETDEWEB)

    Nagae, D., E-mail: nagae@tac.tsukuba.ac.jp; Niwa, T.; Ishibashi, Y.; Abe, Y.; Fukuoka, S.; Nishikiori, R.; Okada, S.; Saito, Y.; Inaba, N.; Ozawa, A. [University of Tsukuba, Institute of Physics (Japan); Aoki, Y. [RIKEN Nishina Center, RIKEN (Japan)

    2013-05-15

    A rotating magnetic field system has been developed to determine the sign of magnetic ({mu}) and quadrupole (Q) moments by means of the {beta}-ray-detected nuclear magnetic resonance ({beta}-NMR) method. The rotating magnetic field is obtained using two crossed Helmholtz-like coils at right angles. The phase angles of the alternating currents for the two coils are shifted by 90 Degree-Sign . Thus the resulting magnetic field is circularly polarized. By the adjustment of the phase-angle difference, a right- or left-circularly polarized magnetic field is produced. Productions of right- or left-rotating magnetic fields including a linear component were confirmed using pickup-coils.

  5. Memory effects and magnetic interactions in a γ-Fe2O3 nanoparticle system

    Science.gov (United States)

    Tsoi, G. M.; Senaratne, U.; Tackett, R. J.; Buc, E. C.; Naik, R.; Vaishnava, P. P.; Naik, V. M.; Wenger, L. E.

    2005-05-01

    The low-temperature dynamics of a magnetic nanoparticle system (γ-Fe2O3—alginate nanocomposite with average particle size around 4nm) have been studied by superconducting quantum interference device measurements. Using different temperature and field protocols, memory phenomena in the dc magnetization and magnetic relaxation have been observed at temperatures below its blocking temperature TB=37K. However, aging experiments show an absence of any waiting time dependence in the magnetization relaxation. These observations indicate that the dynamics of this nanoparticle system are governed by a wide distribution of particle relaxation times which arise from the distribution of particle sizes and weak interparticle interactions.

  6. Magnetic ordering in a Zn substituted CoTiFeO ferrite system

    Science.gov (United States)

    Upadhyay, R. V.; Jotania, R. B.; Kulkarni, R. G.

    1993-07-01

    The magnetic properties of a Zn substituted Co 12- xZn xTi 0.2Fe 1.6O 4 ferrite system is studied using AC susceptibility, magnetization and Mössbauer techniques. The X-ray result confirms the single phase spinel structure for all concentrations. The results suggest that the present system exhibits a para-ferri-cluster spin glass type of magnetic ordering for x ⩽ 0.4 while a for x>0.4 it shows only a cluster spin glass type of magnetic ordering.

  7. Development of an Anti-Vibration Controller for Magnetic Bearing Cooling Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a program to develop a vibration-free reverse-Brayton cycle cooling system using specially-tuned magnetic bearings. Such a system is critical...

  8. Design of Surface Permanent Magnet Synchronous Motor Using Design Assist System for PMSM

    National Research Council Canada - National Science Library

    Yamano, Kenta; Morimoto, Shigeo; Sanada, Masayuki; Inoue, Yukinori

    2017-01-01

    .... In this study, a design assist system is proposed for PMSMs. This system uses motor parameters and a magnetic equivalent circuit to design a PMSM that satisfies the demanded output characteristics...

  9. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  10. Two-dimensional nuclear magnetic resonance of quadrupolar systems

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shuanhu [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    This dissertation describes two-dimensional nuclear magnetic resonance theory and experiments which have been developed to study quadruples in the solid state. The technique of multiple-quantum magic-angle spinning (MQMAS) is extensively reviewed and expanded upon in this thesis. Specifically, MQMAS is first compared with another technique, dynamic-angle spinning (DAS). The similarity between the two techniques allows us to extend much of the DAS work to the MQMAS case. Application of MQMAS to a series of aluminum containing materials is then presented. The superior resolution enhancement through MQMAS is exploited to detect the five- and six-coordinated aluminum in many aluminosilicate glasses. Combining the MQMAS method with other experiments, such as HETCOR, greatly expands the possibility of the use of MQMAS to study a large range of problems and is demonstrated in Chapter 5. Finally, the technique switching-angle spinning (SAS) is applied to quadrupolar nuclei to fully characterize a quadrupolar spin system in which all of the 8 NMR parameters are accurately determined. This dissertation is meant to demonstrate that with the combination of two-dimensional NMR concepts and new advanced spinning technologies, a series of multiple-dimensional NMR techniques can be designed to allow a detailed study of quadrupolar nuclei in the solid state.

  11. Aspects of safety and reliability for fusion magnet systems first annual report

    Energy Technology Data Exchange (ETDEWEB)

    Powell, J. (ed.)

    1976-01-15

    General systems aspects of fusion magnet safety are examined first, followed by specific detailed analyses covering structural, thermal, electrical, and other aspects of fusion magnet safety. The design examples chosen for analysis are illustrative and are not intended to be definitive, since fusion magnet designs are rapidly evolving. Included is a comprehensive collection of design and operating data relating to the safety of existing superconducting magnet systems. The remainder of the overview lists the main conclusions developed from the work to date. These should be regarded as initial steps. Since this study has concentrated on examining potential safety concerns, it may tend to overemphasize the problems of fusion magnets. In fact, many aspects of fusion magnets are well developed and are consistent with good safety practice. A short summary of the findings of this study is given.

  12. Magnetic fields in mixed neutron-star-plus-wormhole systems

    Energy Technology Data Exchange (ETDEWEB)

    Aringazin, Ascar [Institute for Basic Research, Eurasian National University, 5, Munaitpasov Street, Astana, 010008 (Kazakhstan); Dzhunushaliev, Vladimir; Folomeev, Vladimir; Kleihaus, Burkhard; Kunz, Jutta, E-mail: aringazin@gmail.com, E-mail: v.dzhunushaliev@gmail.com, E-mail: vfolomeev@mail.ru, E-mail: b.kleihaus@uni-oldenburg.de, E-mail: jutta.kunz@uni-oldenburg.de [Institut für Physik, Universität Oldenburg, 114-118, Ammerländer Heerstraße, D-26111 Oldenburg (Germany)

    2015-04-01

    We consider mixed configurations consisting of a wormhole filled by a strongly magnetized isotropic or anisotropic neutron fluid. The nontrivial topology of the spacetime is allowed by the presence of exotic matter. By comparing these configurations with ordinary magnetized neutron stars, we clarify the question of how the presence of the nontrivial topology influences the magnetic field distribution inside the fluid. In the case of an anisotropic fluid, we find new solutions describing configurations, where the maximum of the fluid density is shifted from the center. A linear stability analysis shows that these mixed configurations are unstable.

  13. Bead Capture on Magnetic Sensors in a Microfluidic System

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad

    2009-01-01

    The accumulation of magnetic beads by gravitational sedimentation and magnetic capture on a planar Hall-effect sensor integrated in a microfluidic channel is studied systematically as a function of the bead concentration, the fluid flow rate, and the sensor bias current. It is demonstrated...... the fluid flow is defined by the localized magnetic fields from the sensor....... that the sedimentation flux is proportional to the bead concentration and has a power law relation to the fluid flow rate. The mechanisms for the bead accumulation are investigated and it is found that gravitational sedimentation dominates the bead accumulation, whereas the stability of the sedimented beads against...

  14. Probing Gravitational Sensitivity in Biological Systems Using Magnetic Body Forces

    Science.gov (United States)

    Valles, James; Guevorkian, Karine; Wurzel, Samuel; Mihalusova, Mariana

    2003-03-01

    We have commissioned a superconducting solenoid based apparatus designed to exert strong magnetic body forces on biological specimens and other organic materials in ambient environmental conditions for extended periods. In its room temperature bore, it can produce a maximum magnetic field-field gradient product of 16 T^2-cm-1 which is sufficient to levitate frog embryos Xenopus Laevis[1]. We will discuss how we are applying these magnetic body forces to probe the known influences of gravitational forces on frog embryos and the swimming behavior of Paramecium Caudatum. In the process, we will describe a novel method for measuring the diamagnetic susceptibilities of specimens such as paramecia.

  15. Randomized Algorithms for Systems and Control: Theory and Applications

    Science.gov (United States)

    2008-05-01

    Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware...such as Fibonacci , feedback shift register, BBS, MT, … Non-uniform univariate random variables: Suitable functional transformations (e.g., the

  16. PERIPHERAL APPLICATION OF REPETITIVE PULSE MAGNETIC STIMULATION ON JOINT CONTRACTURE FOR MOBILITY RESTORATION: CONTROLLED RANDOMIZED STUDY

    Directory of Open Access Journals (Sweden)

    Efthimios J. Kouloulas

    2016-10-01

    Full Text Available Background: Joint contracture is a limitation in the passive or active range of motion (ROM of a joint, where in addition to the mobility limiting factor the pain is also present. Repetitive pulsed Magnetic Stimulation (rPMS appears to be an effective, non-invasive and safety solution for treating this condition. Therefore aim of this study was to evaluate the effect of rPMS in treating joint contracture. Methods: 30 subjects with joint contracture in the knee were enrolled in this study and divided respectively into Treatment and Control group. The treatment group were delivered with rPMS therapy. The control group was delivered with conventional physiotherapy method (ultrasound. The primary outcome measurements were: 1. Mobility evaluation by goniometry (ROM in degrees while performing flexion and Patient Functional Assessment Questionnaire (PFAQ for ability to perform Activities of Daily Living (ADL and 2. Pain evaluation by 10-point Visual Analog Scale (VAS for pain perception. Absence of adverse events was set as a secondary measure. Results: The results of the study show statistical difference (p<0.05 between the levels of improvement of all studied parameters while comparing between both groups. The results suggest greater immobility restoration and pain relieving effect of the rPMS in comparison to conventional physiotherapy method. Conclusion: rPMS an effective and safe non-invasive method for mobility restoration and pain relief in case of joint contractures. This study suggests the method as beneficial and quality of life ameliorating among patients suffering from immobilized joints accompanied by pain.

  17. On random walks and entropy in diffusion-weighted magnetic resonance imaging studies of neural tissue.

    Science.gov (United States)

    Ingo, Carson; Magin, Richard L; Colon-Perez, Luis; Triplett, William; Mareci, Thomas H

    2014-02-01

    In diffusion-weighted MRI studies of neural tissue, the classical model assumes the statistical mechanics of Brownian motion and predicts a monoexponential signal decay. However, there have been numerous reports of signal decays that are not monoexponential, particularly in the white matter. We modeled diffusion in neural tissue from the perspective of the continuous time random walk. The characteristic diffusion decay is represented by the Mittag-Leffler function, which relaxes a priori assumptions about the governing statistics. We then used entropy as a measure of the anomalous features for the characteristic function. Diffusion-weighted MRI experiments were performed on a fixed rat brain using an imaging spectrometer at 17.6 T with b-values arrayed up to 25,000 s/mm(2). Additionally, we examined the impact of varying either the gradient strength, q, or mixing time, Δ, on the observed diffusion dynamics. In white and gray matter regions, the Mittag-Leffler and entropy parameters demonstrated new information regarding subdiffusion and produced different image contrast from that of the classical diffusion coefficient. The choice of weighting on q and Δ produced different image contrast within the regions of interest. We propose these parameters have the potential as biomarkers for morphology in neural tissue. Copyright © 2013 Wiley Periodicals, Inc.

  18. Bead Capture and Release on a Magnetic Sensor in a Microfluidic System

    DEFF Research Database (Denmark)

    Dalslet, Bjarke Thomas; Damsgaard, Christian Danvad; Freitas, S.C.

    Planar Hall effect magnetic sensors for detection of biological agents using surface treated magnetic beads are integrated with a fluid injection system. The response of the sensors is used to evaluate bead capture rates for different bead concentrations c and fluid flow rates Q, and to monitor...... to capture of beads by the magnetic fields near the sensor. It is shown that beads can be washed off the sensor surface....

  19. A decoupled control approach for magnetic suspension systems using electromagnets mounted in a planar array

    Science.gov (United States)

    Groom, Nelson J.

    1993-01-01

    A decoupled control approach for a Large Gap Magnetic Suspension System (LGMSS) is presented. The control approach is developed for an LGMSS which provides five degree-of-freedom control of a cylindrical suspended element that contains a core composed of permanent magnet material. The suspended element is levitated above five electromagnets mounted in a planar array. Numerical results are obtained by using the parameters of the Large Angle Magnetic Suspension Test Fixture (LAMSTF) which is a small scale laboratory model LGMSS.

  20. ELECTROMAGNETIC SAFETY OF ELECTRIC TRANSPORT SYSTEMS: MAIN SOURCES AND PARAMETERS OF MAGNETIC FIELDS

    Directory of Open Access Journals (Sweden)

    N. G. Ptitsyna

    2013-03-01

    Full Text Available Magnetic fields produced by electric drive vehicles may break electromagnetic safety. For electromagnetic safety and electromagnetic compatibility knowledge about characteristics and sources of magnetic fields in the electric transport is necessary. The article deals with analysis of available data about magnetic fields in electric cars and comparison with results of our measurements carried out in the other types of electrified transport systems.

  1. Doxorubicin-modified magnetic nanoparticles as a drug delivery system for magnetic resonance imaging-monitoring magnet-enhancing tumor chemotherapy.

    Science.gov (United States)

    Liang, Po-Chin; Chen, Yung-Chu; Chiang, Chi-Feng; Mo, Lein-Ray; Wei, Shwu-Yuan; Hsieh, Wen-Yuan; Lin, Win-Li

    2016-01-01

    In this study, we developed functionalized superparamagnetic iron oxide (SPIO) nanoparticles consisting of a magnetic Fe3O4 core and a shell of aqueous stable polyethylene glycol (PEG) conjugated with doxorubicin (Dox) (SPIO-PEG-D) for tumor magnetic resonance imaging (MRI) enhancement and chemotherapy. The size of SPIO nanoparticles was ~10 nm, which was visualized by transmission electron microscope. The hysteresis curve, generated with vibrating-sample magnetometer, showed that SPIO-PEG-D was superparamagnetic with an insignificant hysteresis. The transverse relaxivity (r 2) for SPIO-PEG-D was significantly higher than the longitudinal relaxivity (r 1) (r 2/r 1 >10). The half-life of Dox in blood circulation was prolonged by conjugating Dox on the surface of SPIO with PEG to reduce its degradation. The in vitro experiment showed that SPIO-PEG-D could cause DNA crosslink more serious, resulting in a lower DNA expression and a higher cell apoptosis for HT-29 cancer cells. The Prussian blue staining study showed that the tumors treated with SPIO-PEG-D under a magnetic field had a much higher intratumoral iron density than the tumors treated with SPIO-PEG-D alone. The in vivo MRI study showed that the T2-weighted signal enhancement was stronger for the group under a magnetic field, indicating that it had a better accumulation of SPIO-PEG-D in tumor tissues. In the anticancer efficiency study for SPIO-PEG-D, the results showed that there was a significantly smaller tumor size for the group with a magnetic field than the group without. The in vivo experiments also showed that this drug delivery system combined with a local magnetic field could reduce the side effects of cardiotoxicity and hepatotoxicity. The results showed that the developed SPIO-PEG-D nanoparticles own a great potential for MRI-monitoring magnet-enhancing tumor chemotherapy.

  2. Real-time visualization of magnetic flux densities for transcranial magnetic stimulation on commodity and fully immersive VR systems

    Science.gov (United States)

    Kalivarapu, Vijay K.; Serrate, Ciro; Hadimani, Ravi L.

    2017-05-01

    Transcranial Magnetic Stimulation (TMS) is a non-invasive procedure that uses time varying short pulses of magnetic fields to stimulate nerve cells in the brain. In this method, a magnetic field generator ("TMS coil") produces small electric fields in the region of the brain via electromagnetic induction. This technique can be used to excite or inhibit firing of neurons, which can then be used for treatment of various neurological disorders such as Parkinson's disease, stroke, migraine, and depression. It is however challenging to focus the induced electric field from TMS coils to smaller regions of the brain. Since electric and magnetic fields are governed by laws of electromagnetism, it is possible to numerically simulate and visualize these fields to accurately determine the site of maximum stimulation and also to develop TMS coils that can focus the fields on the targeted regions. However, current software to compute and visualize these fields are not real-time and can work for only one position/orientation of TMS coil, severely limiting their usage. This paper describes the development of an application that computes magnetic flux densities (h-fields) and visualizes their distribution for different TMS coil position/orientations in real-time using GPU shaders. The application is developed for desktop, commodity VR (HTC Vive), and fully immersive VR CAVETM systems, for use by researchers, scientists, and medical professionals to quickly and effectively view the distribution of h-fields from MRI brain scans.

  3. Azido-mediated systems showing different magnetic behaviors.

    Science.gov (United States)

    Zeng, Yong-Fei; Hu, Xin; Liu, Fu-Chen; Bu, Xian-He

    2009-02-01

    Azido has been one of the well used bridging ligands in the construction of magnetic molecule materials, which has stimulated considerable interest in magnetochemistry. This tutorial review is concentrated on the study of azido metal compounds with their magnetochemistry and consists of eight main sections. The first section offers an introduction to azido complexes and some important results obtained from magneto-structural correlation in azido complexes which will be referred to in the following sections. The next six sections give overviews of azido-mediated ferromagnets, ferrimagnets, canted (weak) ferromagnets, antiferromagnets, single molecule magnets (SMMs) and single chain magnets (SCMs), and metamagnets. The last section is the conclusion and gives a perspective of azido-mediated magnets.

  4. Mechanisms of magnetic stimulation of central nervous system neurons

    National Research Council Canada - National Science Library

    Pashut, Tamar; Wolfus, Shuki; Friedman, Alex; Lavidor, Michal; Bar-Gad, Izhar; Yeshurun, Yosef; Korngreen, Alon

    2011-01-01

    .... This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain...

  5. Magnetic resonance urography in children: evaluation of suspected ureteral ectopia in duplex systems.

    Science.gov (United States)

    Staatz, G; Rohrmann, D; Nolte-Ernsting, C C; Stollbrink, C; Haage, P; Schmidt, T; Günther, R W

    2001-12-01

    We evaluate the diagnostic accuracy of magnetic resonance urography in children with suspected ectopic ureters and ureteroceles in duplex systems. A total of 14 children 4 weeks to 8 years old with a total of 18 duplex systems underwent magnetic resonance urography using a 1.5 tesla scanner. After injection of low dose furosemide, half-Fourier rapid acquisition with relaxation enhancement images were obtained for T2-weighted static fluid magnetic resonance urography. Respiratory gated 3-dimensional gradient echo images were acquired for T1-weighted excretory magnetic resonance urography 5 to 30 minutes after intravenously administered gadolinium. All magnetic resonance examinations were successfully performed without sedation. The diagnostic accuracy of T1-weighted excretory magnetic resonance urography depended on the renal function. Twelve duplex systems with a normal excretory function, including 6 bifid ureters and 6 upper moieties with inferomedial ectopic ureters, were analyzed correctly with the exception of a 6 mm. ureterocele in 1 case. In 6 duplex systems with poor or nonfunctioning upper moieties ectopic ureters were only demonstrated on T2-weighted magnetic resonance urograms. Respiratory gated excretory and static fluid magnetic resonance urography complement each other in the evaluation of duplex systems in children and provide high accuracy in the evaluation of suspected ectopic ureters and ureteroceles.

  6. Detection system of magnetic nanoparticles in biological tissues by Magnetoencephalography

    OpenAIRE

    Javorsky, A.; Sanz Lluch, M. del Mar; Maestú, Fernando; Gaztelu, J. M.; Maicas Ramos, Marco Cesar; García-Pacios, J.; Romero-Vives, M.; Barios, J.A.; Pozo Guerrero, Francisco del; Aroca Hernández-Ros, Claudio

    2010-01-01

    Magnetic nanoparticles are useful for a wide range of applications from data storage to medical imaging. Their unique features (controllable size in the nanoscale range, possibility to be coated with biological molecules, response to the application of a magnetic field...) make the development of a variety of medical applications possible, both for diagnosis and therapy [1-3]. On the other hand, Magnetoencephalography (MEG) is a non-invasive functional imaging technique that enables the descr...

  7. GASTRIC RESIDUAL VOLUME BY MAGNETIC RESSONANCE AFTER INTAKE OF MALTODEXTRIN AND GLUTAMINE: a randomized double-blind, crossover study

    Directory of Open Access Journals (Sweden)

    Luigi R BRIANEZ

    2014-06-01

    Full Text Available ContextThe addition of glutamine in preoperative drinks may enhance the benefits of carbohydrate alone.ObjectivesTo evaluate the gastric residual volume after the intake of a beverage containing carbohydrate plus glutamine.MethodsEleven healthy volunteers (24-30 years-old were randomized in a crossover fashion to intake 400 mL (4h before and 200 mL (2h before of a beverage containing either 12.5% maltodextrin (carbohydrate group or 12.5% maltodextrin plus 15 g of glutamine (glutamine group in two different moments 7 days apart. Magnetic ressonance was performed to measure the gastric residual volume (mL 120 and 180 minutes after the last ingestion.ResultsGastric residual volume similar to basal condition was found after 2h and 3h of the intake of beverages. There was no difference in the mean ±SD GRV (mL found at 120 minutes (carbohydrate group: 22.9±16.6 and glutamine group: 19.7±10.7 and at 180 minutes (carbohydrate group: 21.5±24.1 and glutamine group: 15.1±10.1 between the two drinks.ConclusionsGastric emptying is efficient, and occurs in up to two hours after the intake of a beverage containing either carbohydrate alone or carbohydrate associated with glutamine. The addition of glutamine to carbohydrate-enriched drink seems to be safe for the use up to 2h before an operation. HEADINGS - Gastric emptying. Preoperative care. Carbohydrates. Glutamine. Magnetic resonance imaging.

  8. Effects of intranasal oxytocin on thermal pain in healthy men: a randomized functional magnetic resonance imaging study.

    Science.gov (United States)

    Zunhammer, Matthias; Geis, Sandra; Busch, Volker; Greenlee, Mark W; Eichhammer, Peter

    2015-01-01

    Intranasal oxytocin has been shown to affect human social and emotional processing, but its potential to affect pain remains elusive. This randomized, placebo-controlled, double-blind, crossover trial investigated the effect of intranasal oxytocin on the perception and processing of noxious experimental heat in 36 healthy male volunteers. Thermal thresholds were determined according to the Quantitative Sensory Testing protocol. A functional magnetic resonance imaging experiment including intensity and unpleasantness ratings of tonic heat was used to investigate the effects of oxytocin within the brain. Thirty men (aged 18-50 years) were included in the study. Intranasal oxytocin had no significant effect on thermal thresholds, but significantly (t = -2.06, p = .046) reduced heat intensity ratings during functional magnetic resonance imaging. The effect on intensity ratings was small (-3.46 points on a 100-point visual analog scale [95% confidence interval {CI} = -6.86 to -0.07] and independent of temperature. No effects of oxytocin on stimulus- or temperature-related processing were found at the whole-brain level at a robust statistical threshold. A region of interest analysis indicated that oxytocin caused small but significant decreases in left (-0.045%, 95% CI = -0.087 to -0.003, t = -2.19, p = .037) and right (-0.051%, 95% CI = -0.088 to -0.014], t = -2.82, p = .008) amygdala activity across all temperatures. The present study provides evidence for a significant but subtle inhibitory effect of oxytocin on thermal stimulus ratings and concurrent amygdala activity. Neither of the two effects significantly depended of temperature; therefore, the hypothesis of a pain-specific effect of oxytocin could not be confirmed. EUDRA-CT 2009-015115-40.

  9. A randomized comparison of laparoscopic, flexible endoscopic, and wired and wireless magnetic cameras on ex vivo and in vivo NOTES surgical performance.

    Science.gov (United States)

    Chang, Victoria C; Tang, Shou-Jiang; Swain, C Paul; Bergs, Richard; Paramo, Juan; Hogg, Deborah C; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J

    2013-08-01

    The influence of endoscopic video camera (VC) image quality on surgical performance has not been studied. Flexible endoscopes are used as substitutes for laparoscopes in natural orifice translumenal endoscopic surgery (NOTES), but their optics are originally designed for intralumenal use. Manipulable wired or wireless independent VCs might offer advantages for NOTES but are still under development. To measure the optical characteristics of 4 VC systems and to compare their impact on the performance of surgical suturing tasks. VC systems included a laparoscope (Storz 10 mm), a flexible endoscope (Olympus GIF 160), and 2 prototype deployable cameras (magnetic anchoring and guidance system [MAGS] Camera and PillCam). In a randomized fashion, the 4 systems were evaluated regarding standardized optical characteristics and surgical manipulations of previously validated ex vivo (fundamentals of laparoscopic surgery model) and in vivo (live porcine Nissen model) tasks; objective metrics (time and errors/precision) and combined surgeon (n = 2) performance were recorded. Subtle differences were detected for color tests, and field of view was variable (65°-115°). Suitable resolution was detected up to 10 cm for the laparoscope and MAGS camera but only at closer distances for the endoscope and PillCam. Compared with the laparoscope, surgical suturing performances were modestly lower for the MAGS camera and significantly lower for the endoscope (ex vivo) and PillCam (ex vivo and in vivo). This study documented distinct differences in VC systems that may be used for NOTES in terms of both optical characteristics and surgical performance. Additional work is warranted to optimize cameras for NOTES. Deployable systems may be especially well suited for this purpose.

  10. Design of a Compact Dump Resistor System for LCD Magnet

    CERN Document Server

    Gaddi, A

    2010-01-01

    In this technical note we suggest a possible solution for the choice of the detector magnet dump resistor. The push-pull scenario for Linear Collider Detectors imposes new solutions for magnet powering and protection lines, else than what developed for LHC detectors. The magnet dump resistor is the protecting equipment that has the function of extracting a significant amount of magnetic stored energy, from the coil winding to a dump. The LCD magnet has to move with the experiment from the garage to the beam position, so it has to be compact and reliable at the same time. We make here a proposal for a passive water-cooled dumper, we calculate the minimum amount of water required, the resistor hot-spot temperature, the overall mechanical design. The electrical part is not covered by this note, as it can be assumed that the solutions adopted by LHC detector magnets, in terms of quench instrumentation, energy extraction and maximum voltage, are not significantly affected by the push-pull scenario.

  11. An FPGA-based quench detection and protection system for superconducting accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Carcagno, R.H.; Feher, S.; Lamm, M.; Makulski, A.; Nehring, R.; Orris, D.F.; Pischalnikov, Y.; Tartaglia, M.; /Fermilab

    2005-05-01

    A new quench detection and protection system for superconducting accelerator magnets was developed for the Fermilab's Magnet Test Facility (MTF). This system is based on a Field-Programmable Gate Array (FPGA) module, and it is made of mostly commercially available, integrated hardware and software components. It provides all the functions of our existing VME-based quench detection and protection system, but in addition the new system is easily scalable to protect multiple magnets powered independently and a more powerful user interface and analysis tools. The new system has been used successfully for testing LHC Interaction Region Quadrupoles correctors and High Field Magnet HFDM04. In this paper we describe the system and present results.

  12. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  13. SPIN POLARIZATION AND MAGNETIC DICHROISM IN PHOTOEMISSION FROM CORE AND VALENCE STATES IN LOCALIZED MAGNETIC SYSTEMS

    NARCIS (Netherlands)

    THOLE, BT; VANDERLAAN, G

    1991-01-01

    Using group theory we derive a general model for spin polarization and magnetic dichroism in photo-emission in the presence of atomic interactions between the hole created and the valence holes. We predict strong effects in the photoemission from core levels and localized valence levels of

  14. Randomized trial for superiority of high field strength intra-operative magnetic resonance imaging guided resection in pituitary surgery.

    Science.gov (United States)

    Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S

    2017-03-01

    Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Magnetic suspension motorized spindle-cutting system dynamics analysis and vibration control review

    Directory of Open Access Journals (Sweden)

    Xiaoli QIAO

    2016-10-01

    Full Text Available The performance of high-speed spindle directly determines the development of high-end machine tools. The cutting system's dynamic characteristics and vibration control effect are inseparable with the performance of the spindle,which influence each other, synergistic effect together the cutting efficiency, the surface quality of the workpiece and tool life in machining process. So, the review status on magnetic suspension motorized spindle, magnetic suspension bearing-flexible rotor system dynamics modeling theory and status of active control technology of flexible magnetic suspension motorized spindle rotor vibration are studied, and the problems which present in the magnetic suspension flexible motorized spindle rotor systems are refined, and the development trend of magnetic levitation motorized spindle and the application prospect is forecasted.

  16. Dynamics of colloidal systems of magnetic nanoparticles under influence of magnetic fields investigated by XPCS

    Energy Technology Data Exchange (ETDEWEB)

    Schavkan, Alexander

    2017-05-15

    This thesis investigates structural properties and the underlying microscopic dynamics of suspensions of α-FeOOH goethite platelets in water under the influence of magnetic fields. Goethite particles show unusual physical properties and a rich phase diagram, which makes their suspensions an object of high interest for research in the area of ''smart nanoparticles''. Five nanoparticle concentrations were chosen such that different liquid crystal phases could be studied. The suspensions of platelets of these chosen concentrations were exposed to magnetic fields of varying strength. Small angle X-ray scattering and X-ray photon correlation spectroscopy data were taken and evaluated. The appearing phases and phase transitions were studied as a function of concentration and applied magnetic field. For this purpose, order parameters, ellipticity, radial and azimuthal peak positions and widths of scattering features were investigated to clarify the structural properties in detail. For the analysis of the underlying dynamics, the relaxation rates and the shape of measured time correlation functions were evaluated. The results show that with increasing magnetic field a partial realignment of the platelets occurs. This realignment is connected to the magnetic properties of the particles. The dynamics of the corresponding phases revealed a dependence on the concentration of nanoparticles in the suspension. At a concentration of c=20 vol% the transition from the nematic to the anti-nematic phase traverses a mixed state. The nematic and anti-nematic phases show ballistic motion and very similar properties, even though a realignment of the particles from an orientation with the long axis parallel to the applied magnetic field in the nematic phase to an orientation with the long axis perpendicular to the magnetic field in the anti-nematic phase occurs. The mixed state of 20 vol%-suspension exhibits a diffusive motion of the particles and different

  17. RF Head Coil Design with Improved RF Magnetic Near-Fields Uniformity for Magnetic Resonance Imaging (MRI) Systems.

    Science.gov (United States)

    Sohn, Sung-Min; DelaBarre, Lance; Gopinath, Anand; Vaughan, John Thomas

    2014-08-01

    Higher magnetic field strength in magnetic resonance imaging (MRI) systems offers higher signal-to-noise ratio (SNR), contrast, and spatial resolution in MR images. However, the wavelength in ultra-high fields (7 tesla and beyond) becomes shorter than the human body at the Larmor frequency with increasing static magnetic field (B0) of MRI system. At short wavelengths, interference effect appears resulting in non- uniformity of the RF magnetic near-field (B1) over the subject and MR images may have spatially anomalous contrast. The B1 near-field generated by the transverse electromagnetic (TEM) RF coil's microstrip line element has a maximum near the center of its length and falls off towards both ends. In this study, a double trapezoidal shaped microstrip transmission line element is proposed to obtain uniform B1 field distribution by gradual impedance variation. Two multi-channel RF head coils with uniform and trapezoidal shape elements were built and tested with a phantom at 7T MRI scanner for comparison. The simulation and experimental results show stronger and more uniform B1+ near-field with the trapezoidal shape.

  18. A Conduction-Cooled Superconducting Magnet System-Design, Fabrication and Thermal Tests

    DEFF Research Database (Denmark)

    Song, Xiaowei (Andy); Holbøll, Joachim; Wang, Qiuliang

    2015-01-01

    A conduction-cooled superconducting magnet system with an operating current of 105.5 A was designed, fabricated and tested for material processing applications. The magnet consists of two coaxial NbTi solenoid coils with an identical vertical height of 300 mm and is installed in a high...

  19. Modeling of a compliant joint in a Magnetic Levitation System for an endoscopic camera

    NARCIS (Netherlands)

    Simi, M.; Tolou, N.; Valdastri, P.; Herder, J.L.; Menciassi, A.; Dario, P.

    2012-01-01

    A novel compliant Magnetic Levitation System (MLS) for a wired miniature surgical camera robot was designed, modeled and fabricated. The robot is composed of two main parts, head and tail, linked by a compliant beam. The tail module embeds two magnets for anchoring and manual rough translation. The

  20. Construction of Superconducting Magnet System for the J-PARC Neutrino Beam Line

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, T.; Wanderer, P.; Sasaki, K.; Ajima, Y.; Araoka, O.; Fujii, Y.; Hastings, N.; Higashi, N.; Iida, M.; Ishii, T.; Kimura, N.; Kobayashi, T.; Makida, Y.; Nakadaira, T.; Ogitsu, T.; Ohhata, H.; Okamura, T.; Sakashita, K.; Sugawara, S.; Suzuki, S.; Tanaka, K.; Tomaru, T.; Terashima, A.; Yamamoto, A.; Ichikawa, A.; Kakuno, H.; Anerella, M.; Escallier, J.; Ganetis, G.; gupta, R.; Jain, A.; Muratore, J.; Parker, B.; Boussuge, T.; Charrier, J.-P.; Arakawa, M.; Ichihara, T.; Minato, T.; Okada, Y.; Itou, A.; Kumaki, T.; Nagami, M.; Takahashi, T.

    2009-10-18

    Following success of a prototype R&D, construction of a superconducting magnet system for J-PARC neutrino beam line has been carried out since 2005. A new conceptual beam line with the superconducting combined function magnets demonstrated the successful beam transport to the neutrino production target.

  1. Construction and characterisation of a modular microfluidic system: coupling magnetic capture and electrochemical detection

    DEFF Research Database (Denmark)

    Godino, N.; Snakenborg, Detlef; Kutter, Jörg Peter

    2010-01-01

    , and a polycarbonate base where permanent magnets are hosted; these parts are designed to fit so that wire bonding and encapsulation are avoided. This system can perform bioassays over the surface of magnetic beads and uses only 50 mu L of bead suspension per assay. Following detection, captured beads are released...

  2. Magnetic microstructure of nanocrystalline ferromagnets and nanocrystalline systems combining ferromagnetic and antiferromagnetic phases

    Energy Technology Data Exchange (ETDEWEB)

    Loeffler, J.; Wagner, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Kostorz, G. [Eidgenoessische Technische Hochschule, Zurich (Switzerland); Wiedenmann, A. [HMI Berlin (Germany)

    1997-09-01

    Magnetic small-angle neutron scattering measurements were performed on nanostructured ferromagnetic materials on the basis of Fe, Ni and Co, produced preferentially by the inert-gas condensation technique, with the aim to determine the magnetic microstructure of mesoscopic small-particle systems. (author) 1 fig., 3 refs.

  3. A new hybrid protection system for high-field superconducting magnets

    NARCIS (Netherlands)

    Ravaioli, Emanuele; Datskov, V.I.; Kirby, G.; ten Kate, Herman H.J.; Verweij, A.P.

    2014-01-01

    The new generation of high-field superconducting accelerator magnets poses a challenge concerning the protection of the magnet coil in the case of a quench. The very high stored energy per unit volume requires a fast and efficient quench heating system in order to avoid damage due to overheating. A

  4. Finite-momentum condensate of magnetic excitons in a bilayer quantum Hall system

    NARCIS (Netherlands)

    Doretto, R.L.; de Morais Smith, C.; Caldeira, A.O.

    2012-01-01

    We study the bilayer quantum Hall system at total filling factor νT=1 within a bosonization formalism which allows us to approximately treat the magnetic exciton as a boson. We show that in the region where the distance between the two layers is comparable to the magnetic length, the ground state of

  5. Demagnetization harmonic effects on the magnetization of granular systems on a macroscopic scale: the superconducting case

    Science.gov (United States)

    Mancusi, D.; Galluzzi, A.; Pace, S.; Polichetti, M.

    2017-10-01

    A model has been developed to determine the effective ac magnetic response of magnetic systems, taking into account the demagnetization effects arising from the sample geometry which determine the out-of-phase components of the applied fundamental frequency and higher harmonic components. Indeed, demagnetization fields and their intermodulation can significantly affect the ac magnetic response. This approach provides a system of self-consistent linear equations relating the magnetic response to the external magnetic field by means of nonlinear magnetic susceptibility. The model is extended to the magnetic response of granular systems in terms of the contributions of the individual grains and of the whole sample in the presence of demagnetization effects of the whole sample and of the grains on a macroscopic scale. In particular, our model is applied to a granular superconducting system. The comparison between the performed numerical simulations and the experimental data shows that the demagnetization fields of the single grains and of the whole sample, and their intermodulation, are relevant if magnetic measurements are used to extract detailed information about the analyzed material.

  6. Effects of AMM on the EoS of Magnetized Dense Systems

    OpenAIRE

    Paret, D. Manreza; Martinez, A. Perez; Ferrer, E. J.; de la Incera, V

    2014-01-01

    We investigate the effects of the anomalous magnetic moment (AMM) in the EoS of a fermion system in the presence of a magnetic field. In the region of strong magnetic fields ($B>m^2$) the AMM is found from the one-loop fermion self-energy. In contrast to the weak-field AMM found by Schwinger, in the strong magnetic field case, the AMM depends on the Landau level (LL) and decreases with it. The effects of the AMM in the EoS at intermediate-to-large fields can be found introducing the one-loop,...

  7. Repeating pulsed magnet system for axion-like particle searches and vacuum birefringence experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, T., E-mail: yamazaki@icepp.s.u-tokyo.ac.jp [International Center for Elementary Particle Physics, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Inada, T.; Namba, T. [International Center for Elementary Particle Physics, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Asai, S. [Department of Physics, Graduate School of Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Kobayashi, T. [International Center for Elementary Particle Physics, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Matsuo, A.; Kindo, K. [The Institute for Solid State Physics, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-shi, Chiba 277-8581 (Japan); Nojiri, H. [Institute for Materials Research, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan)

    2016-10-11

    We have developed a repeating pulsed magnet system which generates magnetic fields of about 10 T in a direction transverse to an incident beam over a length of 0.8 m with a repetition rate of 0.2 Hz. Its repetition rate is by two orders of magnitude higher than usual pulsed magnets. It is composed of four low resistance racetrack coils and a 30 kJ transportable capacitor bank as a power supply. The system aims at axion-like particle searches with a pulsed light source and vacuum birefringence measurements. We report on the details of the system and its performances.

  8. Measuring system for magnetic field and temperature with digital signal processing

    Directory of Open Access Journals (Sweden)

    Druzhinin A. A.

    2013-10-01

    Full Text Available The measuring system for the magnetic field and temperature using silicon whiskers p-type conductivity as a primary device has been developed. The developed system allows the measurement of the magnetic field and temperature in the temperature range 4,2—77 K, as well as to measure the temperature under the influence of magnetic fields in the range of 100—300 K. It is shown that this system is suitable for the conversion of small signals using a programmable gain amplifier and analog-to-digital converter with high resolution.

  9. Energy extraction system using dual-capacitor switching for quench protection of HTS magnet

    Energy Technology Data Exchange (ETDEWEB)

    Chi, Yo Jong; Song, Seung Hyun; Jeon, Hae Ryong; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Lee, Woo Seung [JH ENGINEERING CO., LTD., Anyang (Korea, Republic of); Kang, Hyoung Ku [Korea National University of Transportation, Chungju (Korea, Republic of)

    2017-09-15

    The superconducting magnets have a large inductance as well as high operating current. Therefore, mega-joule scale energy can be stored in the magnet. The energy stored in the magnet is sufficient to damage the magnet when a quench occurs. Quench heater and dump resistor can be used to protect the magnet. However, using quench heater to create quench resistors through heat transfer can be slower than instantly switching resistors. Also, electrical short, overheating and breakdown can occur due to quench heater. Moreover, the number of dump resistor should be limited to avoid large terminal voltage. Therefore, in this paper, we propose a quench protection method for extracting the energy stored in a magnet by charging and discharging energy through a capacitor switching without increasing resistance. The simulation results show that the proposed system has a faster current decay within the allowable voltage level.

  10. Hemophilic arthropathy. A scoring system for magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soler, R.; Rodriguez, E.; Marini, M. [Department of Radiology, Hospital Juan Canalejo, Coruna (Spain); Lopez-Fernandez, F. [Department of Hematology, Hospital Juan Canalejo, Coruna (Spain)

    2002-04-01

    The aim of this study was to define a system for scoring hemophilic arthropathy (HA) based on MR findings, providing for objective evaluation of the degree of joint involvement and evolution after on-demand administration of FVIII substitutional therapy or prophylactic treatment. A total of 133 MR examinations (89 basal and 44 during follow-up) were performed in 25 patients. Patients were divided in two groups depending on the therapy received and the length of time that the disease had been evolving at the start of the study. Group I was composed of 10 patients with secondary prophylaxis and group II was composed by 15 treated on demand. T1-weighted and T2*-weighted images performed on a 0.5-T unit were prospectively evaluated. The joint involvement was established on a scale of 0 (no abnormalities), I (minimal amount of hemosiderin), II (large amount of hemosiderin and isolated cartilaginous erosion), III (cartilage destruction, bone erosions, and subchondral cysts) to IV (large internal joint derangement, secondary osteoarthritis and/or ankylosis). At basal MR examination, patients of group I showed no abnormalities (n=28, 75.6%), grade I (n=3), and grade II (n=6) of HA. Patients of group II corresponded to MR grades III (n=21) and IV (n=11) of HA. The MR follow-up showed improvement in three joints of group I and worsening in 5 joints in group I and 2 joints in group II. Early signs of HA were detected in 10 joints with MR imaging but were underestimated on plain radiographs. Advanced degrees of HA were classified as severe under both imaging techniques. Magnetic resonance is the preferred imaging technique to assess HA. The earliest signs of joint damage, detected by MR, are overlooked by plain radiography. The MR scoring system can be used for evaluating HA. Follow-up MR should be performed to evaluate regression or worsening of the abnormalities, primarily in the case of patients with prophylaxis who usually suffer normal or early joint involvement not

  11. Towards an improved magnetic diagnostic system for LISA

    Energy Technology Data Exchange (ETDEWEB)

    Mateos, I; Lobo, A; Sanjuan, J [Institut de Ciencies de l' Espai (CSIC-IEEC), Edifici Nexus, Gran Capita 2-4, 08034 Barcelona (Spain); Ramos-Castro, J [Departament d' Enginyeria Electronica, Universitat Politecnica de Catalunya (UPC), Campus Nord, Edifici C4, Jordi Girona 1-3, 08034 Barcelona (Spain); Nofrarias, M, E-mail: mateos@ice.csic.e [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institute), Callinstrasse 38, D-30167 Hannover (Germany)

    2009-03-01

    The current design, and material implementation of the magnetic field sensing in the LISA Technology Package (LTP) on board LISA Pathfinder (LPF), is based on a set of 4 high-precision 3-axis fluxgate magnetometers. In order to avoid magnetic disturbances on the LTP proof masses (TM 's), originated by the sensors themselves, these are placed somewhat far from the TM's, which results in partial field information losses. We are currently investigating alternative magnetic sensing techniques, based on AMR (Anisotropic Magnetoresistive) devices. These are much smaller in size than fluxgates, therefore a more numerous array can be thought of for flight. In addition, there is a chance that they may be attached closer to the TM's, thereby enhancing magnetic field sensing spacial resolution. Several issues need to be addressed, such as real sensitivity (including electronics noise) and set/reset trigger procedures. A brief overview about the stability of the magnetic fields and gradients generated in the LTP by means of the coil will also be given. This paper show the latest results of our research.

  12. System Efficiency Improvement for Electric Vehicles Adopting a Permanent Magnet Synchronous Motor Direct Drive System

    Directory of Open Access Journals (Sweden)

    Chengming Zhang

    2017-12-01

    Full Text Available To improve the endurance mileage of electric vehicles (EVs, it is important to decrease the energy consumption of the Permanent Magnet Synchronous Motor (PMSM drive system. This paper proposes a novel loss optimization control strategy named system efficiency improvement control which can optimize both inverter and motor losses. A nonlinear power converter loss model is built to fit the nonlinear characteristics of power devices. This paper uses double Fourier integral analysis to analytically calculate the fundamental and harmonic components of motor current by which the fundamental motor loss and harmonic motor loss can be accurately analyzed. From these loss models, a whole-frequency-domain system loss model is derived and presented. Based on the system loss model, the system efficiency improvement control method applies the genetic algorithm to adjust the motor current and PWM frequency together to optimize the inverter and motor losses by which the system efficiency can be significantly improved without seriously influence on the system stability over the whole operation range of EVs. The optimal effects of system efficiency is verified by the experimental results in both Si-IGBT-based PMSM system and SiC-MOSFET-based system.

  13. Power supply system for the superconducting outsert of the CHMFL hybrid magnet

    Science.gov (United States)

    Fang, Z.; Zhu, J.; Chen, W.; Jiang, D.; Huang, P.; Chen, Z.; Tan, Y.; Kuang, G.

    2017-12-01

    The construction of a new hybrid magnet, consisting of a 11 T superconducting outsert and a 34 T resistive insert magnet, has been finished at the Chinese High Magnetic Field Laboratory (CHMFL) in Hefei. With a room temperature bore of 800 mm in diameter, the hybrid magnet superconducting outsert is composed of four separate Nb3Sn-based Cable-in-Conduit Conductor (CICC) coils electrically connected in series and powered by a single power supply system. The power supply system for the superconducting outsert consists of a 16 kA DC power supply, a quench protection system, a pair of 16 kA High Temperature Superconducting (HTS) current leads, and two Low Temperature Superconducting bus-lines. The design and manufacturing of the power supply system have been completed at the CHMFL. This paper describes the design features of the power supply system as well as the current fabrication condition of its main components.

  14. Gastric residual volume by magnetic ressonance after intake of maltodextrin and glutamine: a randomized double-blind, crossover study.

    Science.gov (United States)

    Brianez, Luigi R; Caporossi, Cervantes; de Moura, Yure W; Dias, Lorena A; Leal, Regis V; de Aguilar-Nascimento, José E

    2014-01-01

    The addition of glutamine in preoperative drinks may enhance the benefits of carbohydrate alone. To evaluate the gastric residual volume after the intake of a beverage containing carbohydrate plus glutamine. Eleven healthy volunteers (24-30 years-old) were randomized in a crossover fashion to intake 400 mL (4h before) and 200 mL (2h before) of a beverage containing either 12.5% maltodextrin (carbohydrate group) or 12.5% maltodextrin plus 15 g of glutamine (glutamine group) in two different moments 7 days apart. Magnetic ressonance was performed to measure the gastric residual volume (mL) 120 and 180 minutes after the last ingestion. Gastric residual volume similar to basal condition was found after 2h and 3h of the intake of beverages. There was no difference in the mean ±SD GRV (mL) found at 120 minutes (carbohydrate group: 22.9±16.6 and glutamine group: 19.7±10.7) and at 180 minutes (carbohydrate group: 21.5±24.1 and glutamine group: 15.1±10.1) between the two drinks. Gastric emptying is efficient, and occurs in up to two hours after the intake of a beverage containing either carbohydrate alone or carbohydrate associated with glutamine. The addition of glutamine to carbohydrate-enriched drink seems to be safe for the use up to 2h before an operation.

  15. Impact of Magnetic Resonance Imaging on Treatment-Related Decision Making for Osteoporotic Vertebral Compression Fracture: A Prospective Randomized Trial.

    Science.gov (United States)

    Jin, Cong; Xu, Guojian; Weng, Dong; Xie, Minghua; Qian, Yu

    2018-01-03

    BACKGROUND The aim of this study was to analyze the impact and usefulness of characteristic signal change of a linear black signal on magnetic resonance imaging (MRI) on treatment-related decision making. MATERIAL AND METHODS Forty-one patients with a linear black signal on MRI were enrolled in this prospective study. They were randomly divided into the percutaneous kyphoplasty (PKP) group (n=24) and the conservative treatment group (n=17). Clinical measures, including visual analog scale (VAS) and short-form 36 (SF-36) questionnaire, were analyzed. Radiographic measures, including anterior vertebral body height, kyphosis angle and rate of bone-union, were evaluated. RESULTS VAS scores were significantly lower in the PKP group than in the conservative treatment group post-treatment and at one-year follow-up. After one year of treatment, the values for physical functioning, physical health, and body pain were significantly higher in the PKP group than in the conservative treatment group (p<0.05). The PKP group had a significantly higher anterior vertebral body height, rate of bone-union, and lower kyphosis angle than the conservative treatment group at one-year follow-up (p<0.05). CONCLUSIONS In patients with a linear black signal detected on MRI, the first-choice treatment should be PKP rather than conservative treatment.

  16. Perpendicular spin transfer torque magnetic random access memories with high spin torque efficiency and thermal stability for embedded applications (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Luc, E-mail: luc.thomas@headway.com; Jan, Guenole; Zhu, Jian; Liu, Huanlong; Lee, Yuan-Jen; Le, Son; Tong, Ru-Ying; Pi, Keyu; Wang, Yu-Jen; Shen, Dongna; He, Renren; Haq, Jesmin; Teng, Jeffrey; Lam, Vinh; Huang, Kenlin; Zhong, Tom; Torng, Terry; Wang, Po-Kang [TDK-Headway Technologies, Inc., Milpitas, California 95035 (United States)

    2014-05-07

    Magnetic random access memories based on the spin transfer torque phenomenon (STT-MRAMs) have become one of the leading candidates for next generation memory applications. Among the many attractive features of this technology are its potential for high speed and endurance, read signal margin, low power consumption, scalability, and non-volatility. In this paper, we discuss our recent results on perpendicular STT-MRAM stack designs that show STT efficiency higher than 5 k{sub B}T/μA, energy barriers higher than 100 k{sub B}T at room temperature for sub-40 nm diameter devices, and tunnel magnetoresistance higher than 150%. We use both single device data and results from 8 Mb array to demonstrate data retention sufficient for automotive applications. Moreover, we also demonstrate for the first time thermal stability up to 400 °C exceeding the requirement of Si CMOS back-end processing, thus opening the realm of non-volatile embedded memory to STT-MRAM technology.

  17. Research on the reliability of friction system under combined additive and multiplicative random excitations

    Science.gov (United States)

    Sun, Jiaojiao; Xu, Wei; Lin, Zifei

    2018-01-01

    In this paper, the reliability of a non-linearly damped friction oscillator under combined additive and multiplicative Gaussian white noise excitations is investigated. The stochastic averaging method, which is usually applied to the research of smooth system, has been extended to the study of the reliability of non-smooth friction system. The results indicate that the reliability of friction system can be improved by Coulomb friction and reduced by random excitations. In particular, the effect of the external random excitation on the reliability is larger than the effect of the parametric random excitation. The validity of the analytical results is verified by the numerical results.

  18. Acoustic field characterization of a clinical magnetic resonance-guided high-intensity focused ultrasound system inside the magnet bore.

    Science.gov (United States)

    Kothapalli, Satya V V N; Altman, Michael B; Partanen, Ari; Wan, Leighton; Gach, H Michael; Straube, William; Hallahan, Dennis E; Chen, Hong

    2017-09-01

    With the expanding clinical application of magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU), acoustic field characterization of MR-HIFU systems is needed for facilitating regulatory approval and ensuring consistent and safe power output of HIFU transducers. However, the established acoustic field measurement techniques typically use equipment that cannot be used in a magnetic resonance imaging (MRI) suite, thus posing a challenge to the development and execution of HIFU acoustic field characterization techniques. In this study, we developed and characterized a technique for HIFU acoustic field calibration within the MRI magnet bore, and validated the technique with standard hydrophone measurements outside of the MRI suite. A clinical Philips MR-HIFU system (Sonalleve V2, Philips, Vantaa, Finland) was used to assess the proposed technique. A fiber-optic hydrophone with a long fiber was inserted through a 24-gauge angiocatheter and fixed inside a water tank that was placed on the HIFU patient table above the acoustic window. The long fiber allowed the hydrophone control unit to be placed outside of the magnet room. The location of the fiber tip was traced on MR images, and the HIFU focal point was positioned at the fiber tip using the MR-HIFU therapy planning software. To perform acoustic field mapping inside the magnet, the HIFU focus was positioned relative to the fiber tip using an MRI-compatible 5-axis robotic transducer positioning system embedded in the HIFU patient table. To perform validation measurements of the acoustic fields, the HIFU table was moved out of the MRI suite, and a standard laboratory hydrophone measurement setup was used to perform acoustic field measurements outside the magnetic field. The pressure field scans along and across the acoustic beam path obtained inside the MRI bore were in good agreement with those obtained outside of the MRI suite. At the HIFU focus with varying nominal acoustic powers of 10-500 W, the

  19. Induced magnetism in transition metal intercalated graphitic systems

    KAUST Repository

    Kaloni, Thaneshwor P.

    2011-10-26

    We investigate the structure, chemical bonding, electronic properties, and magnetic behavior of a three-dimensional graphitic network in aba and aaa stacking with intercalated transition metal atoms (Mn, Fe, Co, Ni, and Cu). Using density functional theory, we find induced spin-polarization of the C atoms both when the graphene sheets are aba stacked (forming graphite) and aaa stacked (resembling bi-layer graphene). The magnetic moment induced by Mn, Fe, and Co turns out to vary from 1.38 μB to 4.10 μB, whereas intercalation of Ni and Cu does not lead to a magnetic state. The selective induction of spin-polarization can be utilized in spintronic and nanoelectronic applications.

  20. Magnetic field induced order in quasi-one-dimensional systems

    Energy Technology Data Exchange (ETDEWEB)

    Dzyaloshinskii, I.E. [Physics Department, University of California, Irvine, UCI, CA 92697 (United States); Kats, E.I., E-mail: efim.i.kats@gmail.com [Laue-Langevin Institute, F-38042, Grenoble (France); L.D. Landau Institute for Theoretical Physics, RAS, 117940 GSP-1, Moscow (Russian Federation)

    2012-06-25

    We investigate possible ordered phases in a magnetic field in quasi-one-dimensional conductors (Q1D). Long ago [I.E. Dzyaloshinskii, E.I. Kats, JETP 28 (1969) 178] we found that sufficiently strong external magnetic field leads to instability of the Fermi state with an arbitrarily weak repulsion between the particles. In the present communication we generalize this idea and provide more details to assign a physical meaning to such a state. We show that without umklapp processes the found instability corresponds to antiferromagnetic (spin density wave) order, whereas umklapp processes favor to Cooper pairing. -- Highlights: ► Strong magnetic field leads to instability. ► Interparticle repulsion with umklapp processes favor to Cooper pairing. ► Without umklapp processes the instability corresponds to antiferromagnetic order.

  1. Free-energy landscapes in magnetic systems from metadynamics

    Science.gov (United States)

    Tóbik, Jaroslav; MartoÅák, Roman; Cambel, Vladimír

    2017-10-01

    The knowledge of the free-energy barriers separating different states is critically important for the assessment of the long-term stability of information stored in magnetic devices. This information, however, is not directly accessible by standard simulations of microscopic models because of the ubiquitous time-scale problem, related to the fact that the transitions among different free-energy minima are characteristic of rare events. Here, we show that by employing the metadynamics algorithm based on suitably chosen collective variables, namely, helicity and circulation, it is possible to reliably recover the free-energy landscape. We demonstrate the effectiveness of this approach on an example of a vortex nucleation process in a magnetic nanodot with lowered spatial symmetry. With the help of reconstructed free-energy surfaces, we show the origin of symmetry broken vortex nucleation, where one polarity of the nucleated vortex core is preferred, even though only an in-plane magnetic field is present.

  2. Visualization and quantification of magnetic nanoparticles into vesicular systems by combined atomic and magnetic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dong, C. [Department of Basic and Applied Sciences for Engineering, SAPIENZA University of Rome, Via A. Scarpa 16, 00161, Rome (Italy); Department of Physics, SAPIENZA University of Rome, Piazzale A. Moro 5, 00185, Rome (Italy); Corsetti, S.; Passeri, D. [Department of Basic and Applied Sciences for Engineering, SAPIENZA University of Rome, Via A. Scarpa 16, 00161, Rome (Italy); Rossi, M. [Department of Basic and Applied Sciences for Engineering, SAPIENZA University of Rome, Via A. Scarpa 16, 00161, Rome (Italy); Research Center for Nanotechnology applied to Engineering of SAPIENZA University of Rome (CNIS), Piazzale A. Moro 5, 00185, Rome (Italy); Carafa, M.; Marianecci, C., E-mail: carlotta.marianecci@uniroma1.it [Department of Drug Chemistry and Technologies, SAPIENZA University of Rome, Piazzale A. Moro 5, 00185, Rome (Italy); Pantanella, F. [Department of Public Health and Infectious Diseases, SAPIENZA University of Rome, Piazzale A. Moro 5, 00185, Rome (Italy); Research Center for Nanotechnology applied to Engineering of SAPIENZA University of Rome (CNIS), Piazzale A. Moro 5, 00185, Rome (Italy); Rinaldi, F.; Ingallina, C. [Center for Life Nano Science @ Sapienza, Istituto Italiano di Tecnologia, Viale Regina Elena 291, 00161, Rome (Italy); Sorbo, A. [Department of Food Safety and Veterinary Public Health, Istituto Superiore di Sanità (ISS), Viale Regina Elena 299, 00161, Rome (Italy)

    2015-06-23

    We report a phenomenological approach for the quantification of the diameter of magnetic nanoparticles (MNPs) incorporated in non-ionic surfactant vesicles (niosomes) using magnetic force microscopy (MFM). After a simple specimen preparation, i.e., by putting a drop of solution containing MNPs-loaded niosomes on flat substrates, topography and MFM phase images are collected. To attempt the quantification of the diameter of entrapped MNPs, the method is calibrated on the sole MNPs deposited on the same substrates by analyzing the MFM signal as a function of the MNP diameter (at fixed tip-sample distance) and of the tip-sample distance (for selected MNPs). After calibration, the effective diameter of the MNPs entrapped in some niosomes is quantitatively deduced from MFM images.

  3. Performance evaluation of permanent magnet synchronous motor/generator for superconductor flywheel energy storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.P.; Sung, T.H.; Jung, S.V.; Han, Y.H. [Korea Electric Power Energy Research Inst., Daejeon (Korea, Republic of); You, D.J.; Jang, S.M. [Chung Nam National Univ., Daejeon (Korea, Republic of)

    2007-07-01

    Superconductor flywheel energy storage (SFES) systems are used to supply energy when needed during periods of peak electrical use. Stored energy decreases when the rotational speed of the flywheel decreases. Rotational losses occur as a result of induced currents in the superconductors caused by inhomogeneous fields of the permanent magnet (PM) rotor and the eddy current in the rotor induced by the magnetic field of the superconductor. The aim of this modelling study was to improve the storage efficiency of the SFES by reducing rotational losses. A permanent magnet synchronous motor (PMSM) for a SFES system was designed using magnetic field and dynamic modelling. The model consisted of a surface-mounted permanent magnet (PM) rotor with diametrical magnetization and a slotless iron-cored stator. Rotor and stator performance were evaluated in both operational and idling modes. Electromagnetic analyses were conducted to determine PM volume and winding rotations. A 2-D analytical solution was used to characterize the distribution of magnetized materials. Ampere's law was used to solve the field quantities and boundary conditions of the PM. The electrical dynamic equation was characterized as a 3-phase winding in a rotating time domain. Results of the study showed that the PMSM design provided the correct amount of power. It was concluded that magnetic field analyses can be used to accurately calculate core losses for PMSM systems. 6 refs., 1 tab., 12 figs.

  4. Dynamic magnetic susceptibility of systems with long-range magnetic order

    Energy Technology Data Exchange (ETDEWEB)

    Vannette, Matthew Dano [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    The utility of the TDR as an instrument in the study of magnetically ordered materials has been expanded beyond the simple demonstration purposes. Results of static applied magnetic field dependent measurements of the dynamic magnetic susceptibility, χ, of various ferromagnetic (FM) and antiferromagnetic (AFM) materials showing a range of transition temperatures (1-800 K) are presented. Data was collected primarily with a tunnel diode resonator (TDR) at different radio-frequencies (~10-30 MHz). In the vicinity of TC local moment ferromagnets show a very sharp, narrow peak in χ which is suppressed in amplitude and shifted to higher temperatures as the static bias field is increased. Unexpectedly, critical scaling analysis fails for these data. It is seen that these data are frequency dependent, however there is no simple method whereby measurement frequency can be changed in a controllable fashion. In contrast, itinerant ferromagnets show a broad maximum in χ well below TC which is suppressed and shifts to lower temperatures as the dc bias field is increased. The data on itinerant ferromagnets is fitted to a semi-phenomenological model that suggests the sample response is dominated by the uncompensated minority spins in the conduction band. Concluding remarks suggest possible scenarios to achieve frequency resolved data using the TDR as well as other fields in which the apparatus may be exploited.

  5. The choice of the principle of functioning of the system of magnetic levitation for the device of high-performance testing of powder permanent magnets

    Science.gov (United States)

    Shaykhutdinov, D. V.; Gorbatenko, N. I.; Narakidze, N. D.; Vlasov, A. S.; Stetsenko, I. A.

    2017-02-01

    The present article focuses on permanent magnets quality control problems. High-performance direct-flow type systems for the mechanical engineering production processes are considered. The main lack of the existing high-performance direct-flow type systems is a completing phase of movement of a tested product when the movement is oscillatory and abrupt braking may be harmful for high fragility samples. A special system for permanent magnets control is offered. The system realizes the magnetic levitation of a test sample. Active correction of the electric current in magnetizing coils as the basic functioning principle of this system is offered. The system provides the required parameters of the movement of the test sample by using opposite connection of magnetizing coils. This new technique provides aperiodic nature of the movement and limited acceleration with saving of high accuracy and required timeframe of the installation in the measuring position.

  6. CLIQ – Coupling-Loss Induced Quench System for Protecting Superconducting Magnets

    CERN Multimedia

    Ravaioli, E; Kirby, G; ten Kate, H H J; Verweij, A P

    2014-01-01

    The recently developed Coupling-Loss-Induced Quench (CLIQ) protection system is a new method for initiating a fast and voluminous transition to the normal state for protecting high energy density superconducting magnets. Upon quench detection, CLIQ is triggered to generate an oscillating current in the magnet coil by means of a capacitive discharge. This in turn introduces a high coupling loss in the superconductor which provokes a quick transition to the normal state of the coil windings. The system is now implemented for the protection of a two meter long superconducting quadrupole magnet and characterized in the CERN magnet test facility. Various CLIQ configurations with different current injection points are tested and the results compared to similar transients lately measured with a not optimized configuration. Test results convincingly show that the newly tested design allows for a more global quench initiation and thus a faster discharge of the magnet energy. Moreover, the performance of CLIQ for reduc...

  7. CLIC project R&D studies: the magnet system for the 3 TEV

    CERN Document Server

    Modena, Michele

    2017-01-01

    This Note presents the R&D activities done and coordinated by TE-MSC Group on the magnetic system for the CLIC (Compact Linear Collider) project. The main aspects investigated are: the magnetic system definition, basic design for all magnets (i.e. a CLIC Magnet Catalogue), powering and cost evaluation, advanced design and prototyping for the most critical magnet variants. The CLIC layout here considered is the one for the highest collision energy of 3 TeV. This layout was the one studied in detail as baseline for the CLIC Conceptual Design Report that was released in 2012. This Note summarize the activities of about 6 years (2010-2016) done with the contribution of CERN staff (part-time), the contribution of some CERN Project Associates sponsored by the CLIC Project and in collaboration with STCF Daresbury Laboratory (UK).

  8. Magnetic interactions in martensitic Ni-Mn based Heusler systems

    Energy Technology Data Exchange (ETDEWEB)

    Aksoy, Seda

    2010-04-22

    In this work, magnetic, magnetocaloric and structural properties are investigated in Ni-Mn-based martensitic Heusler alloys with the aim to tailor these properties as well as to understand in detail the magnetic interactions in the various crystallographic states of these alloys. We choose Ni{sub 50}Mn{sub 34}In{sub 16} as a prototype which undergoes a martensitic transformation and exhibits field-induced strain and the inverse magnetocaloric effect. Using the structural phase diagram of martensitic Ni-Mn-based Heusler alloys, we substitute gallium and tin for indium to carry these effects systematically closer to room temperature by shifting the martensitic transformation. A magneto-calorimeter is designed and built to measure adiabatically the magnetocaloric effect in these alloys. The temperature dependence of strain under an external magnetic field is studied in Ni{sub 50}Mn{sub 50-x}Z{sub x} (Z: Ga, Sn, In and Sb) and Ni{sub 50}Mn{sub 34}In{sub 16-x}Z{sub x} (Z: Ga and Sn). An argument based on the effect of the applied magnetic field on martensite nucleation is adopted to extract information on the direction of the magnetization easy axis in the martensitic unit cell in Heusler alloys. Parallel to these studies, the structure in the presence of an external field is also studied by powder neutron diffraction. It is demonstrated that martensite nucleation is influenced by cooling the sample under a magnetic field such that the austenite phase is arrested within the martensitic state. The magnetic interactions in Ni{sub 50}Mn{sub 37}Sn{sub 13} and Ni{sub 50}Mn{sub 40}Sb{sub 10} are characterized by using neutron polarization analysis. Below the martensitic transformation temperature, M{sub s}, an antiferromagnetically correlated state is found. Ferromagnetic resonance experiments are carried out on Ni{sub 50}Mn{sub 37}Sn{sub 13} and Ni{sub 50}Mn{sub 34}In{sub 16} to gain more detailed information on the nature of the magnetic interactions. The experimental

  9. [Magnetic resonance angiography in the diagnosis of cerebrovascular diseases in systemic lupus erythematosus].

    Science.gov (United States)

    Pizova, N V; Spirin, N N; Maksimov, G A; Bakhtin, A L

    2004-01-01

    Fifty one patients with systemic lupus erythematous were examined using magnetic resonance angiography (MRA) to determine cerebral hemodynamic features. A comprehensive study revealed different cerebral circulatory changes in this abnormality.

  10. A new hybrid protection system for high-field superconducting magnets

    CERN Document Server

    Ravaioli, E; Kirby, G; ten Kate, H H J; Verweij, A P

    2014-01-01

    The new generation of high-field superconducting accelerator magnets poses a challenge concerning the protection of the magnet coil in the case of a quench. The very high stored energy per unit volume requires a fast and efficient quench heating system in order to avoid damage due to overheating. A new protection system for superconducting magnets is presented, comprising a combination of a novel coupling-loss induced quench (CLIQ) system and conventional quench heaters. CLIQ can provoke a very fast transition to the normal state in coil windings by introducing coupling loss and thus heat in the coil's conductor. The advantage of the hybrid protection system is a global transition, resulting in a much faster current decay, a significantly lower hot-spot temperature, and a more homogeneous temperature distribution in the magnet's coil.

  11. Simple quadratic magneto-optic Kerr effect measurement system using permanent magnets

    Science.gov (United States)

    Pradeep, A. V.; Ghosh, Sayak; Anil Kumar, P. S.

    2017-01-01

    In recent times, quadratic magneto-optic Kerr effect (QMOKE) is emerging as an important experimental tool to investigate higher-order spin-orbit interactions in magnetic thin films and heterostructures. We have designed and constructed a simple, cost-effective QMOKE measurement system using permanent magnets. The permanent magnets are mounted on the inner surface of a cylindrical ferromagnetic yoke which can be rotated about its axis. Our system is sensitive to both the quadratic and linear MOKE signals. We use rotating field method to extract the QMOKE components in saturation. This system is capable of extracting the QMOKE signal from single crystals and thin film samples. Here we present the construction and working of the QMOKE measurement system using permanent magnets and report, for the first time, the QMOKE signal from Fe3O4 single crystal.

  12. A polarised SUSANS facility to study magnetic systems

    Indian Academy of Sciences (India)

    Spatial pair-distribution functions for the up- and down-spins as well as the nuclear and magnetic scattering length density distributions in the micrometer domain, have ... Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400 085, India; Berlin Neutron Scattering Center, Hahn-Meitner-Institut, Glienicker ...

  13. Critical dynamics of an interacting magnetic nanoparticle system

    DEFF Research Database (Denmark)

    Hansen, Mikkel Fougt; Jonsson, P.E.; Nordblad, P.

    2002-01-01

    Effects of dipole-dipole interactions on the magnetic relaxation have been investigated for three Fe-C nanoparticle samples with volume concentrations of 0.06, 5 and 17 vol%. While both the 5 and 17 vol% samples exhibit collective behaviour due to dipolar interactions, only the 17 vol% sample...

  14. Simple System to Measure the Earth's Magnetic Field

    Science.gov (United States)

    Akoglu, R.; Halilsoy, M.; Mazharimousavi, S. Habib

    2010-01-01

    Our aim in this proposal is to use Faraday's law of induction as a simple lecture demonstration to measure the Earths magnetic field (B). This will also enable the students to learn about how electric power is generated from rotational motion. Obviously the idea is not original, yet it may be attractive in the sense that no sophisticated devices…

  15. Observed Faraday Effects in Damped Lyα Absorbers and Lyman Limit Systems: The Magnetized Environment of Galactic Building Blocks at Redshift = 2

    Science.gov (United States)

    Farnes, J. S.; Rudnick, L.; Gaensler, B. M.; Haverkorn, M.; O'Sullivan, S. P.; Curran, S. J.

    2017-06-01

    Protogalactic environments are typically identified using quasar absorption lines and can manifest as Damped Lyman-alpha Absorbers (DLAs) and Lyman Limit Systems (LLSs). We use radio observations of Faraday effects to test whether these galactic building blocks host a magnetized medium, by combining DLA and LLS detections with 1.4 GHz polarization data from the NRAO VLA Sky Survey (NVSS). We obtain a control, a DLA, and an LLS sample consisting of 114, 19, and 27 lines of sight, respectively. Using a Bayesian framework and weakly informative priors, we are unable to detect either coherent or random magnetic fields in DLAs: the regular coherent fields must be ≤slant 2.8 μG, and the lack of depolarization suggests the weakly magnetized gas in DLAs is non-turbulent and quiescent. However, we find a mild suggestive indication that LLSs have coherent magnetic fields, with a 71.5% probability that LLSs have higher | {RM}| than a control, although this is sensitive to the redshift distribution. We also find a strong indication that LLSs host random magnetic fields, with a 95.5% probability that LLS lines of sight have lower polarized fractions than a control. The regular coherent fields within the LLSs must be ≤slant 2.4 μG, and the magnetized gas must be highly turbulent with a typical turbulent length scale on the order of ≈5-20 pc. Our results are consistent with the standard dynamo paradigm, whereby magnetism in protogalaxies increases in coherence over cosmic time, and with a hierarchical galaxy formation scenario, with the DLAs and LLSs exploring different stages of magnetic field evolution in galaxies.

  16. MAGNET

    CERN Multimedia

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  17. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  18. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  19. Stability and dynamical properties of material flow systems on random networks

    Science.gov (United States)

    Anand, K.; Galla, T.

    2009-04-01

    The theory of complex networks and of disordered systems is used to study the stability and dynamical properties of a simple model of material flow networks defined on random graphs. In particular we address instabilities that are characteristic of flow networks in economic, ecological and biological systems. Based on results from random matrix theory, we work out the phase diagram of such systems defined on extensively connected random graphs, and study in detail how the choice of control policies and the network structure affects stability. We also present results for more complex topologies of the underlying graph, focussing on finitely connected Erdös-Réyni graphs, Small-World Networks and Barabási-Albert scale-free networks. Results indicate that variability of input-output matrix elements, and random structures of the underlying graph tend to make the system less stable, while fast price dynamics or strong responsiveness to stock accumulation promote stability.

  20. Optimal strategy analysis based on robust predictive control for inventory system with random demand

    Science.gov (United States)

    Saputra, Aditya; Widowati, Sutrisno

    2017-12-01

    In this paper, the optimal strategy for a single product single supplier inventory system with random demand is analyzed by using robust predictive control with additive random parameter. We formulate the dynamical system of this system as a linear state space with additive random parameter. To determine and analyze the optimal strategy for the given inventory system, we use robust predictive control approach which gives the optimal strategy i.e. the optimal product volume that should be purchased from the supplier for each time period so that the expected cost is minimal. A numerical simulation is performed with some generated random inventory data. We simulate in MATLAB software where the inventory level must be controlled as close as possible to a set point decided by us. From the results, robust predictive control model provides the optimal strategy i.e. the optimal product volume that should be purchased and the inventory level was followed the given set point.

  1. Systemic corticosteroid monotherapy for clinically diagnosed acute rhinosinusitis: a randomized controlled trial

    NARCIS (Netherlands)

    Venekamp, R.P.; Bonten, M.J.; Rovers, M.M.; Verheij, T.J.; Sachs, A.P.

    2012-01-01

    BACKGROUND: Patients with acute rhinosinusitis are frequently encountered in primary care. Although corticosteroids are being increasingly used for symptom control, evidence supporting their use is inconclusive. We conducted a randomized controlled trial to examine the effectiveness of systemic

  2. Mindfulness meditation and the immune system: a systematic review of randomized controlled trials

    National Research Council Canada - National Science Library

    Black, David S; Slavich, George M

    2016-01-01

    .... To address this issue, we conducted the first comprehensive review of randomized controlled trials examining the effects of mindfulness meditation on immune system parameters, with a specific focus on five outcomes: (1...

  3. Instability in time-delayed switched systems induced by fast and random switching

    Science.gov (United States)

    Guo, Yao; Lin, Wei; Chen, Yuming; Wu, Jianhong

    2017-07-01

    In this paper, we consider a switched system comprising finitely or infinitely many subsystems described by linear time-delayed differential equations and a rule that orchestrates the system switching randomly among these subsystems, where the switching times are also randomly chosen. We first construct a counterintuitive example where even though all the time-delayed subsystems are exponentially stable, the behaviors of the randomly switched system change from stable dynamics to unstable dynamics with a decrease of the dwell time. Then by using the theories of stochastic processes and delay differential equations, we present a general result on when this fast and random switching induced instability should occur and we extend this to the case of nonlinear time-delayed switched systems as well.

  4. Robotic vision system for random bin picking with dual-arm robots

    Directory of Open Access Journals (Sweden)

    Kang Sangseung

    2016-01-01

    Full Text Available Random bin picking is one of the most challenging industrial robotics applications available. It constitutes a complicated interaction between the vision system, robot, and control system. For a packaging operation requiring a pick-and-place task, the robot system utilized should be able to perform certain functions for recognizing the applicable target object from randomized objects in a bin. In this paper, we introduce a robotic vision system for bin picking using industrial dual-arm robots. The proposed system recognizes the best object from randomized target candidates based on stereo vision, and estimates the position and orientation of the object. It then sends the result to the robot control system. The system was developed for use in the packaging process of cell phone accessories using dual-arm robots.

  5. Study on MAX-MIN Ant System with Random Selection in Quadratic Assignment Problem

    Science.gov (United States)

    Iimura, Ichiro; Yoshida, Kenji; Ishibashi, Ken; Nakayama, Shigeru

    Ant Colony Optimization (ACO), which is a type of swarm intelligence inspired by ants' foraging behavior, has been studied extensively and its effectiveness has been shown by many researchers. The previous studies have reported that MAX-MIN Ant System (MMAS) is one of effective ACO algorithms. The MMAS maintains the balance of intensification and diversification concerning pheromone by limiting the quantity of pheromone to the range of minimum and maximum values. In this paper, we propose MAX-MIN Ant System with Random Selection (MMASRS) for improving the search performance even further. The MMASRS is a new ACO algorithm that is MMAS into which random selection was newly introduced. The random selection is one of the edgechoosing methods by agents (ants). In our experimental evaluation using ten quadratic assignment problems, we have proved that the proposed MMASRS with the random selection is superior to the conventional MMAS without the random selection in the viewpoint of the search performance.

  6. Protein encapsulated magnetic carriers for micro/nanoscale drug delivery systems.

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Y.; Kaminski, M. D.; Mertz, C. J.; Finck, M. R.; Guy, S. G.; Chen, H.; Rosengart, A. J.; Chemical Engineering; Univ. of Chicago, Pritzker School of Medicine

    2005-01-01

    Novel methods for drug delivery may be based on nanotechnology using non-invasive magnetic guidance of drug loaded magnetic carriers to the targeted site and thereafter released by external ultrasound energy. The key building block of this system is to successfully synthesize biodegradable, magnetic drug carriers. Magnetic carriers using poly(D,L-lactide-co-glycolide) (PLGA) or poly(lactic acid)-poly(ethylene glycol) (PLA-PEG) as matrix materials were loaded with bovine serum albumin (BSA) by a double-emulsion technique. BSA-loaded magnetic microspheres were characterized for size, morphology, surface charge, and magnetization. The BSA encapsulation efficiency was determined by recovering albumin from the microspheres using dimethyl sulfoxide and 0.05N NaOH/0.5% SDS then quantifying with the Micro-BCA protein assay. BSA release profiles were also determined by the Micro-BCA protein assay. The microspheres had drug encapsulation efficiencies up to 90% depending on synthesis parameters. Particles were spherical with a smooth or porous surface having a size range less than 5 {mu}m. The surface charge (expressed as zeta potential) was near neutral, optimal for prolonged intravascular survival. The magnetization of these BSA loaded magnetic carriers was 2 to 6 emu/g, depending on the specific magnetic materials used during synthesis.

  7. Design, Modeling and Control of Magnetic Bearings for a Ring-Type Flywheel Energy Storage System

    Directory of Open Access Journals (Sweden)

    Chow-Shing Toh

    2016-12-01

    Full Text Available This study is concerned with the magnetic force models of magnetic bearing in a flywheel energy storage system (FESS. The magnetic bearing is of hybrid type, with axial passive magnetic bearing (PMB and radial hybrid magnetic bearing (HMB. For the PMB, a pair of ring-type Halbach arrays of permanent magnets are arranged vertically to support the rotor weight. For the HMB, a set of ring-type Halbach array is placed on the rotor side, which corresponds to coil sets on the stator side. The HMB can produce both attraction and repulsion forces on the radial direction, depending on the direction of the coil currents. It is found that the ring-type configuration and the differential winding scheme for coil sets can yield linear magnetic force models for both PMB and HMB. Based on the obtained magnetic force model, an integral sliding mode controller is designed for the stable rotor levitation in the radial direction. The experimental results show that the rotor can be stabilized to the bearing center, verifying the accuracy of the magnetic force models and effectiveness of the levitation controller.

  8. Theoretical investigation on the magnetization enhancement of Fe3O4-reduced graphene oxide nanoparticle system

    Science.gov (United States)

    Majidi, M. A.; Wicaksono, Y.; Fauzi, A. D.; Taufik, A.; Saleh, R.; Rusydi, A.

    2017-04-01

    We present a theoretical study on the enhancement of magnetization of Fe3O4 nanoparticle system upon addition of reduced graphene oxide (rGO). Experimental data have shown that the magnetization of Fe3O4-rGO nanoparticle system increases with increasing rGO content up to about 5 wt%, but decreases back as the rGO content increases further. We propose that the enhancement is due to spin-flipping of Fe ions at the tetrahedral sites assisted by oxygen vacancies at the Fe3O4 particle boundaries. These oxygen vacancies are induced by the presence of rGO flakes that adsorb oxygen atoms from Fe3O4 particles around them. To understand the enhancement of the magnetization, we construct a tight-binding based model Hamiltonian for the Fe3O4 nanoparticle system with the concentration of oxygen vacancies being controlled by the rGO content. We calculate the magnetization as a function of the applied magnetic field for various values of rGO wt%. We use the method of dynamical mean-field theory and perform the calculations for a room temperature. Our result for rGO wt% dependence of the saturated magnetization shows a very good agreement with the existing experimental data of the Fe3O4-rGO nanoparticle system. This result may confirm that our model already carries the most essential idea needed to explain the above phenomenon of magnetization enhancement.

  9. Mobile refrigeration system for precool and warm up of superconducting magnets

    Science.gov (United States)

    Gandla, S. K.; Longsworth, R. C.

    2017-12-01

    Conservation of helium has become more important in recent years due to global shortages in supply. Magnetic resonance imaging (MRI) superconducting magnets use approximately 20% of the world’s helium reserves in liquid form to cool down and maintain operating temperatures at 4 K. This paper describes a mobile cryogenic refrigeration system, which has been developed by Sumitomo (SHI) Cryogenics of America, Inc. to conserve helium by shipping MRI magnets warm and cooling them down or servicing them on site at a medical facility. The system can cool a typical magnet from room temperature to below 40K in less than a week. The system consists of four single stage Displex®-type Gifford-McMahon (GM) expanders in a cryostat with heat exchangers integrated on the cold ends that cool the helium gas, which is circulated in a closed-loop system through the magnet by a cryogenic fan. The system is configured with heaters on the heat exchangers to effectively warm up a magnet. The system includes a scroll vacuum pump, which is used to evacuate the helium circuit with or without the magnet and turbo pump to evacuate the cryostat. Vacuum-jacketed transfer lines connect the cryostat to the magnet. The system is designed with its own controller for continuous operation of precool, warm up and evacuation processes with automatic and manual controls. The cryostat, pumps and gas controls are mounted on a dewar cart. One compressor and the system controller are mounted on a compressor and control cart, and the other three compressors are mounted on separate carts.

  10. Is A Magnetic Sensor Capable of Evaluating A Vision-Based Face Tracking System?

    OpenAIRE

    Yao, Zhengrong; Li, Haibo

    2003-01-01

    This paper addresses an important issue, how to evaluate a vision-based face tracking system? Although nowadays it is getting popular to employ a magnetic sensor to evaluate the performance of such systems. The related issues such as condition and limitation of usage are often omitted. In this paper we studied this accepted evaluation methodology together with another evaluation method, Peak Signal to Noise (PSNR) commonly used inimage coding community. The condition of proper usage of magnet...

  11. Preliminary investigations of design philosophies and features applicable to large magnetic suspension and balance systems

    Science.gov (United States)

    Britcher, C. P.; Fortescue, P. W.; Allcock, G. A.; Goodyer, M. J.

    1979-01-01

    The technology which is required to allow the principles of magnetic suspension and balance systems (MSBS) to be applied to the high Reynolds number transonic testing of aircraft models is examined. A test facility is presented as comprising a pressurized transonic cryogenic wind tunnel, with the MSBS providing full six degree of freedom control. The electro-magnets which are superconducting and fed from quiet, bipolar power supplies are examined. A model control system having some self adaptive characteristics is discussed.

  12. Medical Devices; General and Plastic Surgery Devices; Classification of the Magnetic Surgical Instrument System. Final order.

    Science.gov (United States)

    2016-09-21

    The Food and Drug Administration (FDA) is classifying the Magnetic Surgical Instrument System into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the magnetic surgical instrument system's classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  13. Validation of the OMERACT Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) for the Hand and Foot in a Randomized Placebo-controlled Trial

    DEFF Research Database (Denmark)

    Glinatsi, Daniel; Bird, Paul; Gandjbakhch, Frederique

    2015-01-01

    Objective. To assess changes following treatment and the reliability and responsiveness to change of the Outcome Measures in Rheumatology (OMERACT) Psoriatic Arthritis Magnetic Resonance Imaging Score (PsAMRIS) in a randomized controlled trial. Methods. Forty patients with PsA randomized to either......). Results. Inflammatory features improved numerically but statistically nonsignificantly in the ABA group but not the placebo group. Baseline intrareader intraclass correlation coefficients (ICC) were good (≥ 0.50) to very good (≥ 0.80) for all features in both hand and foot. Baseline interreader ICC were......AMRIS may be a valid tool for MRI assessment of hands and feet in PsA clinical trials....

  14. Stochastic analysis model for vehicle-track coupled systems subject to earthquakes and track random irregularities

    Science.gov (United States)

    Xu, Lei; Zhai, Wanming

    2017-10-01

    This paper devotes to develop a computational model for stochastic analysis and reliability assessment of vehicle-track systems subject to earthquakes and track random irregularities. In this model, the earthquake is expressed as non-stationary random process simulated by spectral representation and random function, and the track random irregularities with ergodic properties on amplitudes, wavelengths and probabilities are characterized by a track irregularity probabilistic model, and then the number theoretical method (NTM) is applied to effectively select representative samples of earthquakes and track random irregularities. Furthermore, a vehicle-track coupled model is presented to obtain the dynamic responses of vehicle-track systems due to the earthquakes and track random irregularities at time-domain, and the probability density evolution method (PDEM) is introduced to describe the evolutionary process of probability from excitation input to response output by assuming the vehicle-track system as a probabilistic conservative system, which lays the foundation on reliability assessment of vehicle-track systems. The effectiveness of the proposed model is validated by comparing to the results of Monte-Carlo method from statistical viewpoint. As an illustrative example, the random vibrations of a high-speed railway vehicle running on the track slabs excited by lateral seismic waves and track random irregularities are analyzed, from which some significant conclusions can be drawn, e.g., track irregularities will additionally promote the dynamic influence of earthquakes especially on maximum values and dispersion degree of responses; the characteristic frequencies or frequency ranges respectively governed by earthquakes and track random irregularities are greatly different, moreover, the lateral seismic waves will dominate or even change the characteristic frequencies of system responses of some lateral dynamic indices at low frequency.

  15. Deep Learning the Quantum Phase Transitions in Random Two-Dimensional Electron Systems

    Science.gov (United States)

    Ohtsuki, Tomoki; Ohtsuki, Tomi

    2016-12-01

    Random electron systems show rich phases such as Anderson insulator, diffusive metal, quantum Hall and quantum anomalous Hall insulators, Weyl semimetal, as well as strong/weak topological insulators. Eigenfunctions of each matter phase have specific features, but owing to the random nature of systems, determining the matter phase from eigenfunctions is difficult. Here, we propose the deep learning algorithm to capture the features of eigenfunctions. Localization-delocalization transition, as well as disordered Chern insulator-Anderson insulator transition, is discussed.

  16. Magnetic links among lava flows, tuffs and the underground plumbing system in a monogenetic volcano, derived from magnetics and paleomagnetic studies

    Science.gov (United States)

    Urrutia-Fucugauchi, Jaime; Trigo-Huesca, Alfonso; Pérez-Cruz, Ligia

    2012-12-01

    A combined study using magnetics and paleomagnetism of the Toluquilla monogenetic volcano and associated lavas and tuffs from Valsequillo basin in Central Mexico provides evidence on a 'magnetic' link between the lavas, ash tuffs and the underground volcanic conduit system. Paleomagnetic analyses show that the lava and ash tuff carry reverse polarity magnetizations, which correlate with the inversely polarized dipolar magnetic anomaly over the volcano. The magnetizations in the lava and tuff show similar southward declinations and upward inclinations, supporting petrological inferences that the tuff was emplaced while still hot and indicating a temporal correlation for lava and tuff emplacement. Modeling of the dipolar anomaly gives a reverse polarity source magnetization associated with a vertical prismatic body with southward declination and upward inclination, which correlates with the reverse polarity magnetizations in the lava and tuff. The study documents a direct correlation of the paleomagnetic records with the underground magmatic conduit system of the monogenetic volcano. Time scale for cooling of the volcanic plumbing system involves a longer period than the one for the tuff and lava, suggesting that magnetization for the source of dipolar anomaly may represent a long time average as compared to the spot readings in the lava and tuff. The reverse polarity magnetizations in lava and tuff and in the underground source body for the magnetic anomaly are interpreted in terms of eruptive activity of Toluquilla volcano at about 1.3 Ma during the Matuyama reverse polarity C1r.2r chron.

  17. DESIGN AND TESTING OF A DIGITAL REGULATOR FOR FERMILAB MAGNET POWER SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Li Vigni, Vincenzo [Palermo U.

    2012-01-01

    In this thesis, the design of a digitally controlled DC power system for testing conventional and superconducting magnets is proposed. The designed PID controller performances have been tested by the 30kA test stand for superconducting magnets, Vertical Magnet Test Facility (VMTF), which is hosted at the Fermilab Magnet Test Facility (MTF). The system is implemented on a National Instruments CompactRIO and both real-time and FPGA targets are programmed. A full 24-bit PID algorithm is coded and successfully tested by a manual tuning approach. An automated tuning algorithm is then introduced. As it will be shown by simulation and experimental results, the proposed system meets all design specifications. The current loop stability is up to 14 times better than the existing regulator and a control accuracy less than 4 ppm is achieved. Shorted-bus tests of the PID regulator have been successfully performed on the VMTF power system. In order to test the generalization capability of the designed system towards different types of magnets, the system has been easily adapted to and tested on the 10kA conventional magnet test stand (Stand C at Fermilab). As shown by experimental results, the designed PID controller features really high performancesin terms of steady-state accuracy and effectiveness of the tuning algorithm.

  18. Some Open Problems in Random Matrix Theory and the Theory of Integrable Systems. II

    Science.gov (United States)

    Deift, Percy

    2017-03-01

    We describe a list of open problems in random matrix theory and the theory of integrable systems that was presented at the conference Asymptotics in Integrable Systems, Random Matrices and Random Processes and Universality, Centre de Recherches Mathématiques, Montréal, June 7-11, 2015. We also describe progress that has been made on problems in an earlier list presented by the author on the occasion of his 60^{th} birthday in 2005 (see [Deift P., Contemp. Math., Vol. 458, Amer. Math. Soc., Providence, RI, 2008, 419-430, arXiv:0712.0849]).

  19. Magnetic field induced tunneling and relaxation between orthogonal configurations in solids and molecular systems

    Science.gov (United States)

    Averkiev, N. S.; Bersuker, I. B.; Gudkov, V. V.; Zhevstovskikh, I. V.; Baryshnikov, K. A.; Sarychev, M. N.; Zherlitsyn, S.; Yasin, S.; Korostelin, Yu. V.

    2017-09-01

    We report the effect of magnetic field induced quantum tunneling and relaxation transitions between orthogonal configurations in polyatomic systems where no tunneling is expected. Typical situations of this kind occur in molecular systems and local centers in crystals in ground and excited electronic T states, subject to the T ⊗e problem of the Jahn-Teller effect, where the wave functions of the three tetragonally distorted configurations are orthogonal. A detailed microscopic theory of this effect shows how the magnetic field violates the orthogonality between the latter allowing for tunneling and relaxations, which decrease in strong fields due to the induced decoherence. The novel effect is demonstrated experimentally as a big, sharp peak in ultrasound attenuation by Cr2 + centers in ZnSe:Cr2 + in the magnetic field B =0.15 T at the temperature below 8 K. It may influence a variety of magnetic, electronic, and photonic properties of any system in an electronic T state.

  20. Novel magnet-retained prosthetic system for facial reconstruction.

    Science.gov (United States)

    Ahmed, Mostafa M; Piper, James M; Hansen, Nancy A; Sutton, Alan J; Schmalbach, Cecelia E

    2014-01-01

    Traumatic facial defects negatively impact speech, mastication, deglutition, dental hygiene, and psychosocial well-being. Reconstruction must address restoration of function and aesthetics to provide quality of life. This report describes soft-tissue reconstruction using a novel magnet-retained facial prosthesis without osseointegrated abutments, performed in a patient after traumatic loss of the entire left lower part of the face, including lips, commissure, and mentum. This reconstructive technique successfully addressed the cosmetic defect while also restoring function with respect to speech and oral nutrition. For this reason, magnet-retained facial prosthesis should be added to free tissue transfer and regional flaps as a reasonable option in the reconstructive algorithm for complex soft-tissue defects of the lower face.