WorldWideScience

Sample records for radon monitoring system

  1. Real Time and Multiple Location Radon (222Rn Monitoring System

    Directory of Open Access Journals (Sweden)

    MORARIU, G.

    2010-11-01

    Full Text Available The paper presents a Radon monitoring system. The system is designed for real time multiple location monitoring. The paper presents in the first part a method and an instrument for measuring radon concentration in air. Simulink simulations and implementation of the measurement principle are presented. Instrument position is determined by GPS and transmitted over GPRS along with the measurements results. Data management is accomplished by a software component of the system. The paper presents as an application, an investigation on nanomaterials to be used for Radon mitigation.

  2. Comparison of four types of passive and integrated and sensitive radon monitors

    CERN Document Server

    Zhao Gui Zhi

    2002-01-01

    In order to improve the sensitivity of radon measurement method, Fast and Multi-functional Radon Monitor with Electret, Sensitive Miner Radon Monitor, fast and Multifunctional Radon Monitor with High Voltage and PCMR-1 Passive and Continuous Radon Monitor were developed. Except Sensitive Miner Radon Monitor suits for radon concentration measurement only, the others can be used to measure both radon concentration and radon flux rate. Their measurement principles. specifications, quality assurance system, advantages and disadvantages are introduced. The simultaneous measurement results indicate that the errors among them are less than 5% and 10%, respectively, for the average radon concentration measurement and for the average radon flux rate measurement

  3. Development of a continuous radon concentration monitoring system in underground soil

    Science.gov (United States)

    Yamamoto, S.; Tarutani, K.; Yamasoto, K.; Iskandar, D.; Iida, T.

    2001-06-01

    A continuous radon (Rn-222) concentration monitoring system for use in underground soil was developed and tested. The system consists of a 19-mm-diameter, 1100-mm-long detector assembly and a microprocessor based data logger. A small volume chamber is installed at the tip of the detector assembly. A thin ZnS(Ag) scintillator film inside the chamber and a photomultiplier tube (PMT) detect alpha particles from radon and its daughters. When the system is in measurement, the detector part is buried into underground soil. An energy resolution of approximately 70% full width half maximum (FWHM) was obtained for 5.5 MeV alpha particles from Am-241. Both the rise time and fall time for the system were measured to be approximately 1-2 h. Temporal variations in underground radon concentration at different depths were investigated simultaneously using four sets of the developed system. The results confirmed that the developed system is useful for continuous measurement of radon concentration in underground soil.

  4. Radon surveys and monitoring at active volcanoes: an open window on deep hydrothermal systems and their dynamics

    Science.gov (United States)

    Cigolini, Corrado; Laiolo, Marco; Coppola, Diego

    2017-04-01

    The behavior of fluids in hydrothermal systems is critical in volcano monitoring and geothermal prospecting. Analyzing the time series of radon emissions on active volcanoes is strategic for detecting and interpreting precursory signals of changes in volcanic activity, eventually leading to eruptions. Radon is a radioactive gas generated from the decay of U bearing rocks, soils and magmas. Although radon has been regarded as a potential precursor of earthquakes, radon anomalies appear to be better suited to forecast volcanic eruptions since we know where paroxysms may occur and we can follow the evolution of volcanic activity. Radon mapping at active volcanoes is also a reliable tool to assess diffuse and concentrated degassing as well as efficiently detecting earthquake-volcano interactions. Systematic radon monitoring has been shown to be a key factor for evaluating the rise of volcanic and hydrothermal fluids. In fact, the decay properties of radon, the duration of radon anomalies together with sampling rates may be cross-checked with the chemistry of hydrothermal fluids (and their transport properties) to constrain fluids ascent rates and to infer the permeability and porosity of rocks in sectors surrounding the active conduits. We hereby further discuss the data of radon surveys and monitoring at Somma-Vesuvius, Stromboli and La Soufrière (Guadeloupe, Lesser Antilles). The integrated analysis of seismic and geochemical data, including radon emissions, may be successfully used in testing temperature distributions and variations of porosity and permeability in volcanic hydrothermal systems and can be used as a proxy to analyze geothermal reservoirs.

  5. Electronic radon monitoring with the CMOS System-on-Chip AlphaRad

    Energy Technology Data Exchange (ETDEWEB)

    Higueret, S. [Institut Pluridisciplinaire Hubert Curien (IPHC) UMR 7500 CNRS/IN2P3, 23 rue du Loess, BP 28, F-67037 Strasbourg Cedex 2 (France); Husson, D. [Institut Pluridisciplinaire Hubert Curien (IPHC) UMR 7500 CNRS/IN2P3, 23 rue du Loess, BP 28, F-67037 Strasbourg Cedex 2 (France)], E-mail: Daniel.Husson@ires.in2p3.fr; Le, T.D.; Nourreddine, A. [Institut Pluridisciplinaire Hubert Curien (IPHC) UMR 7500 CNRS/IN2P3, 23 rue du Loess, BP 28, F-67037 Strasbourg Cedex 2 (France); Michielsen, N. [Institut de Radioprotection et de Surete Nucleaire (IRSN, DSU-SERAC-LPMA), BP 68, 91192 Gif-sur-Yvette Cedex (France)

    2008-01-11

    The development of the integrated circuit AlphaRad as a new System-on-Chip for detection of {alpha}-particles has already been reported. This paper deals with electronic monitoring of atmospheric radon, which is one of the promising applications of the chip. The future electronic radon monitor (ERM) is designed to be compact, inexpensive, operating at low voltage and fully stand-alone. We present here the complete electronic board of the future ERM: it is made of three independent AlphaRad chips running in parallel, mounted on a small printed-circuit board which includes a numeric block for data treatment based on a Xilinx programmable gate array. The maximal counting rate of the AlphaRad chip has been pushed to at least 3x10{sup 6} {alpha}-particles cm{sup -2}. The complete system for detection of the solid aerosols will be published separately, and this paper will focus on the electronic board alone. Already 20 times faster than our first measurement with a CMOS pixel sensor, the system was tested at low and high activities, showing an excellent linearity for {sup 222}Rn levels up to 80 kBq m{sup -3}.

  6. A self-calibrating radon monitor with statistical discrimination

    CERN Document Server

    Valcov, N

    2002-01-01

    A radon monitor, able to perform the measurement of the radon and its progeny volumic activity, in a gamma-ray or natural radiation background field, was developed. The instrument consists of a 10 l ionization chamber, a high voltage source, an integrating preamplifier, a data acquisition system and a personal computer. A new method for self-calibration of Radon volumic activity measurements, based on the alpha counting with an ionization chamber is also presented.

  7. Radon monitoring and hazard prediction in Ireland

    Science.gov (United States)

    Elio, Javier; Crowley, Quentin; Scanlon, Ray; Hodgson, Jim; Cooper, Mark; Long, Stephanie

    2016-04-01

    Radon is a naturally occurring radioactive gas which forms as a decay product from uranium. It is the largest source of natural ionizing radiation affecting the global population. When radon is inhaled, its short-lived decay products can interact with lung tissue leading to DNA damage and development of lung cancer. Ireland has among the highest levels of radon in Europe and eighth highest of an OECD survey of 29 countries. Every year some two hundred and fifty cases of lung cancer in Ireland are linked to radon exposure. This new research project will build upon previous efforts of radon monitoring in Ireland to construct a high-resolution radon hazard map. This will be achieved using recently available high-resolution airborne gamma-ray spectrometry (radiometric) and soil geochemistry data (http://www.tellus.ie/), indoor radon concentrations (http://www.epa.ie/radiation), and new direct measurement of soil radon. In this regard, legacy indoor radon concentrations will be correlated with soil U and Th concentrations and other geogenic data. This is a new approach since the vast majority of countries with a national radon monitoring programme rely on indoor radon measurements, or have a spatially limited dataset of soil radon measurements. Careful attention will be given to areas where an indicative high radon hazard based on geogenic factors does not match high indoor radon concentrations. Where such areas exist, it may imply that some parameter(s) in the predictive model does not match that of the environment. These areas will be subjected to measurement of radon soil gas using a combination of time averaged (passive) and time dependant (active) measurements in order to better understand factors affecting production, transport and accumulation of radon in the natural environment. Such mapping of radon-prone areas will ultimately help to inform when prevention and remediation measures are necessary, reducing the radon exposure of the population. Therefore, given

  8. Comparison of radon doses based on different radon monitoring approaches.

    Science.gov (United States)

    Vaupotič, Janja; Smrekar, Nataša; Žunić, Zora S

    2017-04-01

    In 43 places (23 schools, 3 kindergartens, 16 offices and one dwelling), indoor radon has been monitored as an intercomparison experiment, using α-scintillation cells (SC - Jožef Stefan Institute, Slovenia), various kinds of solid state nuclear track detectors (KfK - Karlsruhe Institute of Technology, Germany; UFO - National Institute of Radiological Sciences, Chiba, Japan; RET - University College Dublin, Ireland) and active electronic devices (EQF, Sarad, Germany). At the same place, the radon levels and, consequently, the effective doses obtained with different radon devices differed substantially (by a factor of 2 or more), and no regularity was observed as regards which detector would show a higher or lower dose. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The NIST Primary Radon-222 Measurement System

    OpenAIRE

    Coll, R.; Hutchinson, J. M. R.; Unterweger, M. P.

    1990-01-01

    Within the United States, the national standard for radon measurements is embodied in a primary radon measurement system that has been maintained for over 50 years to accurately measure radon (222Rn) against international and national radium (226Ra) standards. In turn, all of the radon measurements made at the National Institute of Standards and Technology (NIST) and the radon transfer calibration standards and calibration services provided by NIST are directly related to this national radon ...

  10. The NIST Primary Radon-222 Measurement System.

    Science.gov (United States)

    Collé, R; Hutchinson, J M R; Unterweger, M P

    1990-01-01

    Within the United States, the national standard for radon measurements is embodied in a primary radon measurement system that has been maintained for over 50 years to accurately measure radon ((222)Rn) against international and national radium ((226)Ra) standards. In turn, all of the radon measurements made at the National Institute of Standards and Technology (NIST) and the radon transfer calibration standards and calibration services provided by NIST are directly related to this national radon standard. This primary radon measurement system consists of pulse ionization chambers and ancillary gas handling and gas purification equipment. The system is currently undergoing a significant upgrading and expansion which will replace the extant outdated system.

  11. Ambient Radon-222 Monitoring in Amargosa Valley, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    L.H. Karr; J.J. Tappen; D. Shafer; K.J. Gray

    2008-06-05

    As part of a program to characterize and baseline selected environmental parameters in the region around the proposed repository at Yucca Mountain, Nevada, ambient radon-222 monitoring was conducted in the rural community of Amargosa Valley, the community closest to the proposed repository site. Passive integrating radon monitors and a continuous radon monitoring instrument were deployed adjacent to the Community Environmental Monitoring Program (CEMP) (http://www.cemp.dri.edu/index.html) station located in the Amargosa Valley Community Center near the library. The CEMP station provided real-time ambient gamma exposure and meteorological data used to correct the integrated radon measurements as well as verify meteorological data collected by the continuous radon monitoring instrument. Additionally, different types of environmental enclosures that housed the monitors and instrument were used to determine if particular designs influenced the ambient radon measurements.

  12. Radon monitoring and early low background counting at the Sanford Underground Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, K.J.; Mei, D.M.; Heise, J.; Durben, D.; Salve, R.

    2010-09-01

    Radon detectors have been deployed underground at the Sanford Underground Laboratory at the site of the former Homestake Mine in Lead, SD. Currently, no radon mitigation measures are in place in the underground environment, and the continuing evolution of the facility ventilation systems has led to significant variations in early airborne radon concentrations. The average radon concentration measured near the primary ventilation intake for the 4850-ft level (Yates shaft) is 391 Bq/m{sup 3}, based on approximately 146 days of data. The corresponding average radon concentration near the other main ventilation intake for the 4850-ft level (Ross shaft) is 440 Bq/m{sup 3} based on approximately 350 days of data. Measurements have also been collected near the 1250-ft level Ross shaft, with average radon concentrations at 180 Bq/m{sup 3}. Secondary factors that may increase the baseline radon level underground include the presence of iron oxide and moisture, which are known to enhance radon emanation. The results of the current radon monitoring program will be used for the planning of future measurements and any potential optimization of ventilation parameters for the reduction of radon in relevant areas underground.

  13. Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia

    Energy Technology Data Exchange (ETDEWEB)

    Bartolo, D. de; Alberici, A.; Gallini, R.; Maggioni, T.; Mondini, A.; Zini, E. [A.R.P.A. della Lombardia, Milano (Italy); Arrigoni, S.; Cazzaniga, P.; Cugini, A.; Gallinari, G.; Olivieri, F.; Romanelli, M. [A.R.P.A. della Lombardia, Dipt. di Bergamo, Bergamo (Italy)

    2006-07-01

    Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The measurements were carried out using C.R. 39 trace detector technique. The detectors were contained in closed plastic canisters and they were positioned in situ for one year and measured each semester. The detectors were chemically treated and the traces counted using the automated optical system installed at the Radiometric Laboratory of the A.R.P.A. Department in Bergamo. The instrument accuracy and precision were evaluated using data obtained with different methods: using detectors exposed to radon known concentrations, participating to an international intercomparison as well as exposing the detector in a national calibration centre. Due to the large amount of detectors involved, a particular attention was taken for the detector homogeneity response and for the optimization of the analysis parameters. For further investigating the reliability of the measurements, two detectors were used in parallel in 10% of the tests. The results show higher values in the areas of Bergamo, Brescia

  14. Determination of recharge fraction of injection water in combined abstraction-injection wells using continuous radon monitoring.

    Science.gov (United States)

    Lee, Kil Yong; Kim, Yong-Chul; Cho, Soo Young; Kim, Seong Yun; Yoon, Yoon Yeol; Koh, Dong Chan; Ha, Kyucheol; Ko, Kyung-Seok

    2016-12-01

    The recharge fractions of injection water in combined abstraction-injection wells (AIW) were determined using continuous radon monitoring and radon mass balance model. The recharge system consists of three combined abstraction-injection wells, an observation well, a collection tank, an injection tank, and tubing for heating and transferring used groundwater. Groundwater was abstracted from an AIW and sprayed on the water-curtain heating facility and then the used groundwater was injected into the same AIW well by the recharge system. Radon concentrations of fresh groundwater in the AIWs and of used groundwater in the injection tank were measured continuously using a continuous radon monitoring system. Radon concentrations of fresh groundwater in the AIWs and used groundwater in the injection tank were in the ranges of 10,830-13,530 Bq/m3 and 1500-5600 Bq/m3, respectively. A simple radon mass balance model was developed to estimate the recharge fraction of used groundwater in the AIWs. The recharge fraction in the 3 AIWs was in the range of 0.595-0.798. The time series recharge fraction could be obtained using the continuous radon monitoring system with a simple radon mass balance model. The results revealed that the radon mass balance model using continuous radon monitoring was effective for determining the time series recharge fractions in AIWs as well as for characterizing the recharge system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Radon

    Science.gov (United States)

    ... or Measurement and Mitigation Professional Radon in Drinking Water Radon Hotlines and Resources ( En Español ) Radon Publications ( En Español ) En Español - Acerca del radón Home Buyers and Sellers Radon Protection: Buying a Home Radon Protection: Building a Home ...

  16. Novel Radon Sub-Slab Suctioning System

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    A new principle for radon protection is currently presented which makes use of a system of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground-floor slab. The function of this system is based on the principles of pressure reduction within...... the zone below the ground-floor construction. For this purpose a new system of prefabricated lightweight elements is introduced. The effectiveness of the system is demonstrated for the case of a ground-floor reinforced concrete slab situated on top of a rigid insulation layer (consisting of a thermal...... a grid of horizontal air ducts with low pressure which are able to remove air and radon from the ground. Results showed the system to be effective in preventing radon infiltrating from the ground through the ground-floor slab, avoiding high concentrations of radon being accumulated inside houses...

  17. On-line continuous monitoring of groundwater radon levels at L’Aquila fault, Italy

    Science.gov (United States)

    Tsabaris, C.; Lampousis, A.

    2009-12-01

    This work describes in situ radon progeny measurements in the Gran Sasso National Laboratory (LNGS) of L’Aquila region, located 60 miles north-east of Rome, Italy, conducted in December 2007. The marine radon progeny monitor KATERINA (i.e., Hellenic Centre for Marine Research patent July 2008) was submerged inside a tank filled with groundwater from the Gran Sasso Mountain. The measured spectra obtained through KATERINA exhibited photopeaks of the main gamma emitters (214Pb and 214Bi) of the primordial nucleus 238U (222Rn). High background levels of radionuclides (i.e., inside the mountain) emitting high energy gamma rays affected the measurement. In order to correct and deduce the final volumetric activities of radon progenies (214Pb and 214Bi) the system was calibrated using the simulation tool GEANT4. The first day of deployment an averaged value of radon progenies amounted to a value of (3.1 ± 0.3) Bq/l. The second day the averaged values of radon progenies were reduced by 30% due to the loss of noble gas radon from the tank. Additional spectra were recorded successfully after removing background airborne radon present in the LNGS laboratory. KATERINA operated reliably during its in situ radon monitoring. This was confirmed by further calibration using off line measurements performed in collaboration with the Marine Environmental Laboratory of the International Atomic Energy Agency (IAEA). Future work includes the development of a continuous radon monitoring tool to further study the L’Aquila fault. By implementing a continuous inflow and outflow system and by controlling the radon levels both inside and outside the water tank, radon variations will be correlated with other geophysical/geochemical parameters like microseismicity, slip rates, pH, H2S, CO2, and He. Additional contributions include an increased understanding of the correlations between radon levels in the proximity of active faults and regional seismic activity. If indeed this proves to be an

  18. Radon

    Science.gov (United States)

    ... forming a different element with different radioactive properties. Radium and then radon are formed midway through these ... the main source of health concerns. The main isotope of health concern is radon-222 ( 222 Rn). ...

  19. Long term continuous radon monitoring in a seismically active area

    CERN Document Server

    Piersanti, A; Galli, G

    2015-01-01

    We present the results of a long term, continuous radon monitoring experiment started in April 2010 in a seismically active area, affected during the 2010-2013 data acquisition time window by an intense micro seismic activity and by several small seismic events. We employed both correlation and cross-correlation analyses in order to investigate possible relationship existing between the collected radon data, seismic events and meteorological parameters. Our results do not support the feasibility of a robust one-to-one association between the small magnitude earthquakes characterizing the local seismic activity and single radon measurement anomalies, but evidence significant correlation patterns between the spatio-temporal variations of seismic moment release and soil radon emanations, the latter being anyway dominantly modulated by meteorological parameters variations.

  20. RADON MITIGATION IN SCHOOLS: CASE STUDIES OF RADON MITIGATION SYSTEMS INSTALLED BY EPA IN FOUR MARYLAND SCHOOLS ARE PRESENTED

    Science.gov (United States)

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air-conditioning -- HVAC-- system design and operation) that influence radon entry and mitigation system ...

  1. Artificial neural network model for earthquake prediction with radon monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kuelahci, Fatih [Science and Art Faculty, Physics Department, Firat University, Elazig 23169 (Turkey)], E-mail: fatihkulahci@firat.edu.tr; Inceoez, Murat [Engineering Faculty, Geology Department, Firat University, Elazig 23169 (Turkey); Dogru, Mahmut [Science and Art Faculty, Physics Department, Firat University, Elazig 23169 (Turkey)], E-mail: mdogru@firat.edu.tr; Aksoy, Ercan [Engineering Faculty, Geology Department, Firat University, Elazig 23169 (Turkey); Baykara, Oktay [Education Faculty, Science Education Division, Firat University, Elazig 23169 (Turkey)

    2009-01-15

    Apart from the linear monitoring studies concerning the relationship between radon and earthquake, an artificial neural networks (ANNs) model approach is presented starting out from non-linear changes of the eight different parameters during the earthquake occurrence. A three-layer Levenberg-Marquardt feedforward learning algorithm is used to model the earthquake prediction process in the East Anatolian Fault System (EAFS). The proposed ANN system employs individual training strategy with fixed-weight and supervised models leading to estimations. The average relative error between the magnitudes of the earthquakes acquired by ANN and measured data is about 2.3%. The relative error between the test and earthquake data varies between 0% and 12%. In addition, the factor analysis was applied on all data and the model output values to see the statistical variation. The total variance of 80.18% was explained with four factors by this analysis. Consequently, it can be concluded that ANN approach is a potential alternative to other models with complex mathematical operations.

  2. Radon continuous monitoring in Altamira Cave (northern Spain) to assess user's annual effective dose.

    Science.gov (United States)

    Lario, J; Sánchez-Moral, S; Cañaveras, J C; Cuezva, S; Soler, V

    2005-01-01

    In this work, we present the values of radon concentration, measured by continuous monitoring during a complete annual cycle in the Polychromes Hall of Altamira Cave in order to undertake more precise calculations of annual effective dose for guides and visitors in tourist caves. The (222)Rn levels monitored inside the cave ranges from 186 Bq m(-3) to 7120 Bq m(-3), with an annual average of 3562 Bq m(-3). In order to more accurately estimate effective dose we use three scenarios with different equilibrium factors (F=0.5, 0.7 and 1.0) together with different dose conversion factors proposed in the literature. Neither effective dose exceeds international recommendations. Moreover, with an automatic radon monitoring system the time remaining to reach the maximum annual dose recommended could be automatically updated.

  3. Radon isotope measurements as a monitoring tool for CO2 leakage in geological storage

    Science.gov (United States)

    Grandia, F.; Mazadiego, L. F.; de Elío, J.; Ortega, M.; Bruno, J.

    2011-12-01

    Early detection of the failure of the seal integrity is fundamental in the monitoring plan of a deep geological CO2 storage. A number of methods of leakage control are based on changes in fluid geochemistry (shallow water, soil gases) providing valuable indicators. Among them, the measurement of CO2 fluxes in the soil-atmosphere interface is commonly used since it can be easily done using portable infra-red analyzers (i.e., accumulation chambers). However, initial emission of CO2 from storage horizon could be masked by fluxes from biological activity, limiting its applicability as an early alarm system. The measurement of fluxes of trace gas (Rn, He, VOC) that are virtually absent in the pre-injection baseline turns out a promising complementary method. The measurement of radon isotopes has been long used for the observation of mass transport from deep reservoirs to surface despite the flux of 222Rn and 220Rn is usually very limited in sedimentary basins due to the short half-life of these isotopes. The enhanced transport of radon in CO2 fluxes has been reported from natural systems, resulting in concentration in air up to several thousands of Bq/m3. In the frame of the Compostilla pilot plant project in Spain, a number of methodologies to measure radon emission are being tested in natural systems to select of the most reliable and cost-effective method to be used in leakage control. These methods are (1) Scintillation detector EDA RD-200, (2) Track Etch °, (3) Ionization Chamber and (4) alpha spectroscopy SARAD RTM 200. Some of them are capable of measuring the isotopes separately (SARAD) whereas others just detect the bulk radon concentration. Also, these methods follow distinct procedures and acquisition times. The studied natural sites are located in central and NE Spain (Campo de Calatrava and La Selva basins), and in central Italy (Arezzo basin). Apparently, radon isotopes (up 200000 Bq/m3) are measured far from parent isotopes, and they are coupled to

  4. Radon monitoring in sites of economical importance in Jamaica.

    Science.gov (United States)

    Grant, C N; Lalor, G C; Balcázar, M

    2012-12-01

    The main task was to evaluate possible radon risk to the public and workers in four caves of economical importance. Green Grotto Cave is a large labyrinthine limestone cave, open to the tourism; kept Rn concentration in the range 30-40 Bq m(-3). Xtabil a coral limestone sea cave is part of a beach resort resulted in very low radon concentration of 10 Bq m(-3). Windsor is an intricate limestone cave system showed Rn concentration in the range 250-350 Bq m(-3). Whereas the Oxford caves, is situated in a region of high radioactivity in soil due to the bauxite mines, reached a maximum of 2592 Bq m(-3). Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Monitoring and descriptive analysis of radon in relation to seismic activity of Northern Pakistan.

    Science.gov (United States)

    Jilani, Zeeshan; Mehmood, Tahir; Alam, Aftab; Awais, Muhammad; Iqbal, Talat

    2017-06-01

    Earthquakes are one of the major causes of natural disasters and its forecasting is challenging task. Some precursory phenomenon exists in theory in relation to earthquakes occurrence. The emission of radioactive gas named 'radon' before the earthquakes is a potential earthquake precursory candidate. The study aims to monitor and to analyze the radon in relation to seismic activity in Northern Pakistan. For this purpose RTM-2200 has been used to monitor the changes in radon concentration from August 01, 2014 to January 31, 2015 in Northern Pakistan. Significant temporal variations has been observed in radon concentration. The bivariate analysis of radon with other variables manifests its positive relationship with air pressure and relative humidity and negative relationship with temperature. 2σ upper control limit on monthly basis are computed for detection of anomalous trends in the data. Overall increasing trend is detected in radon concentration. Five earthquakes from August 01, 2014 to January 31, 2015 have been selected from earthquake catalogue, depending upon their magnitude and distance from monitoring station and out of which radon concentration can be associated with only two earthquakes correlated with tectonic effect of radon concentration. Both of events have same magnitude 5.5 and occurred on September 13 and October 14, 2014 respectively. Very large variations have been observed in radon for the last two months of the study period, which may be occurred due to some other geological and environmental changes, but are not related to the earthquake activity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Radon and the system of radiological protection.

    Science.gov (United States)

    Lecomte, J F

    2012-01-01

    At its meeting in Porto, Portugal, in November 2009, the Main Commission of the International Commission on Radiological Protection (ICRP) approved the formation of a new Task Group, reporting to Committee 4, to develop guidance on radiological protection against radon exposure. This article describes the Task Group's draft report entitled "Radiological Protection against Radon Exposure" which has been posted on the ICRP website for public consultation between January and June 2012. In this report, the Commission provides updated guidance on radiological protection against radon exposure. The report was developed considering the recently consolidated ICRP general recommendations, the new scientific knowledge about radon risk, and the experience gained by many organisations and countries in the control of radon exposure. The report describes the characteristics of radon exposure, covering sources and transfer mechanisms, nature of the risk, exposure conditions, similarities with other existing exposure situations, and challenges to manage radon exposure. In order to control radon exposure, the Commission recommends an integrated approach that is focused as much as possible on the management of the building or location in which radon exposure occurs, regardless of the purpose of the building and the category of the occupants. This approach is based on the optimisation principle, and a graded approach according to the degree of responsibilities at stake, notably in workplaces, and the level of ambition of the national authorities. The report emphasises the importance of preventive actions, and provides recommendations on how to control radon exposure in workplaces when workers' exposure can reasonably be regarded as being the responsibility of the operating management. In such a case, workers' exposures are considered to be occupational, and are controlled using the corresponding requirements on the basis of the optimisation principle, and application, as appropriate

  7. Monitoring trends in civil engineering and their effect on indoor radon.

    Science.gov (United States)

    Ringer, W

    2014-07-01

    In this paper, the importance of monitoring new building concepts is discussed. The effect of energy-efficient construction technologies on indoor radon is presented in more detail. Comparing the radon levels of about 100 low-energy and passive houses in Austria with radon levels in conventional new houses show that, in energy-efficient new houses, the radon level is about one-third lower than in conventional new houses. Nevertheless, certain features or bad practice may cause high radon levels in energy-efficient new houses. Recommendations to avoid adverse effects were set up. Furthermore, the paper deals with the effect of thermal retrofitting on indoor radon. Results from a Swiss study where 163 dwellings were measured before and after thermal retrofit yield an increase of the radon level of 26% in average. Among the various retrofit measures, replacing windows has the greatest impact on the indoor radon level. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Radon Sub-slab Suctioning System Integrated in Insulating Layer

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    This poster presents a new radon sub-slab suctioning system. This system makes use of a grid of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground floor slab. For this purpose a new system of prefabricated lightweight elements is introduced...

  9. RADON MITIGATION IN SCHOOLS: HVAC SYTEMS IN SCHOOLS TEND TO HAVE A GREATER IMPACT ON RADON LEVELS THAN HVAC SYSTEMS IN HOMES

    Science.gov (United States)

    The first part of this two-part paper discusses radon entry into schools, radon mitigation approaches for schools, and school characteristics (e.g., heating, ventilation, and air conditioing -- HVAC-- system design and operationg) that influence radon entry and mitigation system ...

  10. Radon continuous monitoring in Altamira Cave (northern Spain) to assess user's annual effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Lario, J. [Departamento Ingenieria Geologica y Minera, Facultad de Ciencias del Medio Ambiente, Universidad de Castilla-La Mancha, 45071 Toledo (Spain)]. E-mail: javier.lario@uclm.es; Sanchez-Moral, S. [Museo Nacional de Ciencias Naturales - CSIC, c/ Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Canaveras, J.C. [Departamento CC. de la Tierra y del Medio Ambiente. Universidad de Alicante, 03080 Alicante (Spain); Cuezva, S. [Museo Nacional de Ciencias Naturales - CSIC, c/ Jose Gutierrez Abascal 2, 28006 Madrid (Spain); Soler, V. [Instituto de Productos Naturales y Agrobiologiaa, CSIC. Avda.Astrofisico Fco. Sanchez, 3, 38206 La Laguna, Tenerife (Spain)

    2005-07-01

    In this work, we present the values of radon concentration, measured by continuous monitoring during a complete annual cycle in the Polychromes Hall of Altamira Cave in order to undertake more precise calculations of annual effective dose for guides and visitors in tourist caves. The {sup 222}Rn levels monitored inside the cave ranges from 186 Bq m{sup -3} to 7120 Bq m{sup -3}, with an annual average of 3562 Bq m{sup -3}. In order to more accurately estimate effective dose we use three scenarios with different equilibrium factors (F=0.5, 0.7 and 1.0) together with different dose conversion factors proposed in the literature. Neither effective dose exceeds international recommendations. Moreover, with an automatic radon monitoring system the time remaining to reach the maximum annual dose recommended could be automatically updated.

  11. Consideration of tidal influences in determining measurement periods when monitoring built-environment radon levels

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, R.G.M.; Phillips, P.S. [Northampton Univ., School of Applied Sciences (United Kingdom); Gillmore, G.K. [Bradford Univ., School of Archaeological, Geographical and Environmental Sciences (United Kingdom); Denman, A.R.; Groves-Kirkby, C.J. [Northampton General Hospital, Medical Physics Dept. (United Kingdom)

    2006-07-01

    Using three hourly-sampling continuous radon monitors, deployed at separate locations in and around the town of Northampton, UK, during the period May 2002 to September 2005, evidence has been identified of tidal influences on built environment radon levels. The data-sets from these deployments, together with additional data-sets collected from a house in Devon, UK, over the period May 1994 to October 1996, and made available by the UK Building Research Establishment, have been analysed using a number of analytical techniques, including a novel cortion technique developed during the investigation. Radon concentration levels in all of the investigated sites exhibit cyclic variation with a period of approximately 14-15 days, equivalent to the spring-tide interval, and lag the corresponding new and full moons by varying periods. The tide/radon lag interval for the two public-sector buildings changes abruptly in September/October, indicating that a significant characteristic of these buildings changes at this time. For domestic properties, the lag is relatively unchanged during the year, but is greater in Devon, in the South-West of England, than in Northampton, in the English East Midlands. These differences are attributed to location relative to coastlines (the South-West experiences greater tidal-loading than the Midlands), underlying geology and rock/soil hydration. Depending on its position within the local 14 to 15-day tidally-induced radon cycle, an individual 7-day radon measurement may yield an erroneous estimate of longer term average levels, up to 46% higher or lower than the average level for one of the reported data-sets. Thus a building with a mean radon concentration below the local Action Level could appear to be unsafe if measured around a tidal-cyclic radon maximum: conversely, a building with a mean radon concentration above the Action Level could appear to be safe when measured around a tidal-cyclic radon minimum. A minimum radon-measurement period

  12. Radon Monitoring in Army Stand-Alone Housing Units

    Science.gov (United States)

    1990-04-01

    damage lung tissue and lead I to increased risk of developing lang cancer . Your risk of developing lung cancer from exposure to radon depends upon the...of developing lung cancer than exposure to a significantly elevated level for a short time. In general, your risk increases as the level of radon and...000mm 0Mmm *000 OOO 0 0w 0 0 000 -0-0 *4 0 880 mama 0 0000000000 000 000Eca ( el cN) 00 9 ’ qqO .00 1(10 0 -U M w co SEE wSS SEES NSEwESO m v MM O v mm

  13. Radon exposure and tumors of the central nervous system.

    Science.gov (United States)

    Ruano-Ravina, Alberto; Dacosta-Urbieta, Ana; Barros-Dios, Juan Miguel; Kelsey, Karl T

    2017-03-15

    To review the published evidence of links between radon exposure and central nervous system tumors through a systematic review of the scientific literature. We performed a thorough bibliographic search in Medline (PubMed) and EMBASE. We combined MeSH (Medical Subject Heading) terms and free text. We developed a purpose-designed scale to assess the quality of the included manuscripts. We have included 18 studies, 8 performed on miners, 3 on the general population and 7 on children, and the results have been structured using this classification. The results are inconclusive. An association between radon exposure and central nervous system tumors has been observed in some studies on miners, but not in others. The results observed in the general adult population and in children are also mixed, with some research evincing a statistically significant association and others showing no effect. We cannot conclude that there is a relationship between radon exposure and central nervous system tumors. The available studies are extremely heterogeneous in terms of design and populations studied. Further research is needed in this topic, particularly in the general population residing in areas with high levels of radon. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Measurement of 224Ra and 226Ra activities in natural waters using a radon-in-air monitor

    Science.gov (United States)

    Kim, G.; Burnett, W.C.; Dulaiova, H.; Swarzenski, P.W.; Moore, W.S.

    2001-01-01

    We report a simple new technique for measuring low-level radium isotopes (224Ra and 226Ra) in natural waters. The radium present in natural waters is first preconcentrated onto MnO2-coated acrylic fiber (Mn fiber) in a column mode. The radon produced from the adsorbed radium is then circulated through a closed air-loop connected to a commercial radon-in-air monitor. The monitor counts alpha decays of radon daughters (polonium isotopes) which are electrostatically collected onto a silicon semiconductor detector. Count data are collected in energy-specific windows, which eliminate interference and maintain very low backgrounds. Radium-224 is measured immediately after sampling via 220Rn (216Po), and 226Ra is measured via 222Rn (218Po) after a few days of ingrowth of 222Rn. This technique is rapid, simple, and accurate for measurements of low-level 224Ra and 226Ra activities without requiring any wet chemistry. Rapid measurements of short-lived 222Rn and 224Ra, along with long-lived 226Ra, may thus be made in natural waters using a single portable system for environmental monitoring of radioactivity as well as tracing of various geochemical and geophysical processes. The technique could be especially useful for the on-site rapid determination of 224Ra which has recently been found to occur at elevated activities in some groundwater wells.

  15. Radium and radon tracers in aquatic systems

    Science.gov (United States)

    Moran, S. B.

    2012-10-01

    Fourth International Ra-Rn Workshop;Narragansett, Rhode Island, 3-8 June 2012 Radium (Ra) and radon (Rn) are widely recognized as important geochemical tracers in the estimation of dispersion in aquatic environments, submarine groundwater discharge (SGD) to the coastal ocean, water mass residence times, and air-sea and water- sediment exchange. More than 50 scientists, including graduate students and early- career scientists from 10 countries, recently participated in a workshop on Ra and Rn in Narragansett, R. I. The workshop was hosted by the University of Rhode Island and sponsored by the U.S. National Science Foundation Chemical Oceanography Program, ORTEC, Eichrom, and Durridge Company. The workshop provided a forum for presentations and open discussions regarding the latest developments and new directions in the application and measurement of isotopes 223Ra, 224Ra, 226Ra, 228Ra, and 222Rn, as well as models used in the application of these tracers to a range of environmental problems.

  16. Construction and measurements of an improved vacuum-swing-adsorption radon-mitigation system

    Energy Technology Data Exchange (ETDEWEB)

    Street, J., E-mail: joseph.street@mines.sdsmt.edu; Bunker, R.; Dunagan, C.; Loose, X.; Schnee, R. W.; Stark, M.; Sundarnath, K.; Tronstad, D. [Department of Physics, South Dakota School of Mines & Technology, Rapid City, SD 57701 (United States)

    2015-08-17

    In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation system and cleanroom build upon a previous design implemented at Syracuse University that achieved radon levels of ∼0.2 Bq m{sup −3}. This improved system will employ a better pump and larger carbon beds feeding a redesigned cleanroom with an internal HVAC unit and aged water for humidification. With the rebuilt (original) radon mitigation system, the new low-radon cleanroom has already achieved a > 300× reduction from an input activity of 58.6 ± 0.7 Bq m{sup −3} to a cleanroom activity of 0.13 ± 0.06 Bq m{sup −3}.

  17. Remote online monitoring of radon wells used for therapy in bathtubs

    Science.gov (United States)

    von Philipsborn, Henning

    2017-04-01

    Sibyllenbad, in the community of Neualbenreuth, 140 km NNE of Regensburg, is well known for two radon wells and one containing carbon dioxide. The water is used pure or mixed for therapy in 200 L bathtubs for a number of indications. Since its beginning, 26 years ago, the author is active in measuring radon and radon decay products and their factor of equilibrium in air and in water for radiation protection of the personnel and for radon water quality assurance for the patients. For the special local operating conditions - high time resolution of measurements is asked - novel measuring methods and instruments were developed. These proved to be useful for several other applications, not foreseen at the beginning. Recently, a probe was installed for online monitoring of water entering the main water storage tank of 42 m3, at the Kurhaus, two km from the radon wells. The probe consists of a 51 mm x 76 mm NaI (Tl) scintillator with photomultiplier, immersed in continuously flowing water in an 8 L pot. The MCA registers the pulses between 200 and 650 keV of the Rn decay products Pb-214 and Bi-214. Specially developed software calculates the gross [cps] from the total counts for variable counting times. The background, determined separately, is subtracted and the net is multiplied with a calibration factor [Bq/L per net cps], determined separately. The activity concentration [Bq/L] of the radon decay products in water is plotted vs. real time (plot P). With Teamviewer, remote online monitoring is possible from the Radiometric Seminar. At the Rn wells, the flow rate [L/s] of the discontinuously working pumps and the lowering of the water level in [m] is measured online. The two quantities are directly correlated, and with a time lag to the demand of radon water from the Kurhaus. Several series of discrete measurements of water, both at the well and at the storage tank, fresh and after 1, 2 and 3 h after storage in full, closed bottles, reveal factors of equilibrium k

  18. Soil-gas radon monitoring in an active granite quarry from central Portugal

    Science.gov (United States)

    Pereira, A. J. S. C.; Barbosa, S. M.; Neves, L. J. P. F.; Aumento, F.

    2011-07-01

    Seven soil-gas radon monitoring stations were placed along the active front of a granite quarry in Canas de senhorim, Central Portugal, recording continuously for 81 days. Important differences in the radon concentration were found between stations, with average values comprised between 102 and 2982 Bq m-3, which can be explained by the local presence of uranium anomalies in the regional late-orogenic Hercynian granite, usually associated with faults. One of the boreholes exhibits large radon anomalies lasting for several days, and two, contrary to the others, show a clear daily periodic behaviour, with minima around 19:00 LT and maxima around 07:00 LT. The different patterns observed in stations placed at such a short distance (<100 m) has no clear explanation and deserves further investigation. Data analysis shows no evidence of soil-gas radon concentration changes during explosions carried out at the quarry. This is likely to result from the absence of a progressive stress field affecting the rock, as typically occurs before an earthquake.

  19. Soil-gas radon monitoring in an active granite quarry from central Portugal

    Directory of Open Access Journals (Sweden)

    A. J. S. C. Pereira

    2011-07-01

    Full Text Available Seven soil-gas radon monitoring stations were placed along the active front of a granite quarry in Canas de senhorim, Central Portugal, recording continuously for 81 days. Important differences in the radon concentration were found between stations, with average values comprised between 102 and 2982 Bq m−3, which can be explained by the local presence of uranium anomalies in the regional late-orogenic Hercynian granite, usually associated with faults. One of the boreholes exhibits large radon anomalies lasting for several days, and two, contrary to the others, show a clear daily periodic behaviour, with minima around 19:00 LT and maxima around 07:00 LT. The different patterns observed in stations placed at such a short distance (<100 m has no clear explanation and deserves further investigation. Data analysis shows no evidence of soil-gas radon concentration changes during explosions carried out at the quarry. This is likely to result from the absence of a progressive stress field affecting the rock, as typically occurs before an earthquake.

  20. Use of a geographic information system (GIS) for targeting radon screening programs in South Dakota.

    Science.gov (United States)

    Kearfott, Kimberlee J; Whetstone, Zachary D; Rafique Mir, Khwaja M

    2016-01-01

    Because (222)Rn is a progeny of (238)U, the relative abundance of uranium may be used to predict the areas that have the potential for high indoor radon concentration and therefore determine the best areas to conduct future surveys. Geographic Information System (GIS) mapping software was used to construct maps of South Dakota that included levels of uranium concentrations in soil and stream water and uranium deposits. Maps of existing populations and the types of land were also generated. Existing data about average indoor radon levels by county taken from a databank were included for consideration. Although the soil and stream data and existing recorded average indoor radon levels were sparse, it was determined that the most likely locations of elevated indoor radon would be in the northwest and southwest corners of the state. Indoor radon levels were only available for 9 out of 66 counties in South Dakota. This sparcity of data precluded a study of correlation of radon to geological features, but further motivates the need for more testing in the state. Only actual measurements should be used to determine levels of indoor radon because of the strong roles home construction and localized geology play in radon concentration. However, the data visualization method demonstrated here is potentially useful for directing resources relating to radon screening campaigns. © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  1. Monitoring of radon activity in natural sources of drinking water near Ekaterinburg city

    Energy Technology Data Exchange (ETDEWEB)

    Semenischev, Vladimir S.; Lezhnina, Marina Ju. [Ural federal university, 620002 Ekaterinburg (Russian Federation)

    2014-07-01

    Quality of water resources used as drinking and domestic water becomes lower because of constant increasing of anthropogenic pressure on environment including hydrosphere. Surface water (rivers, lakes, etc.) used in large cities as primary sources for centralized water supply is usually the most contaminated. Considerable part of citizens in most cities often use alternative sources of drinking water because of ver low quality of tap water. Underground water from boreholes and springs is one of popular alternative sources of drinking water, meanwhile such water may contain considerable amounts of natural toxic pollutants including natural radionuclides. Among natural radionuclides presenting in underground water the most contribution in radiation dose is connected with radionuclides of uranium and thorium families, mainly Rn-222 and in a less degree Ra-226. For example, contribution of radon in average annual radiation dose for population of Sverdlovsk region (Urals, Russia) is 75 - 80%, whereas contribution of anthropogenic sources (excluding medicine) is not more than 0.01%. Analysis of specific activity of radon in several most often used springs and boreholes in Ekaterinburg city west outskirts as well as in tap water was made in this work. Activity of Rn-222 in water samples were measured by low background germanium semiconductor gamma spectrometer 'G??50-?4' via equilibrium Bi-214 (608 keV) in standard Marinelli vessel (1 L). It was shown that specific activity of Rn-222 in tested sources vary within 15 up to 110 Bq/L. The highest specific activity of radon was observed in 'Memory spring' where it was 1.5 - 2 times higher than maximum permissible activity (in Russia maximum permissible activity of radon for drinking water is 60 Bq/L). Monitoring of variations of radon activities in this spring was exercised from January 2013 to November 2013. Water flow discharge in this spring strongly depends on season and is 8 - 9 L/min in winter up to

  2. Seismo-volcanic monitoring at Furnas Volcano (Azores): radon (222Rn) concentration in groundwater

    Science.gov (United States)

    Silva, Catarina; Virgílio Cruz, José; Ferreira, Teresa; Viveiros, Fátima; Freire, Pedro; Allard, Patrick

    2017-04-01

    environmental conditions as soil temperature, rainfall and soil water content, rather than by volcanic activity, with the exception of one spring where radon activity seems to change more closely relate to the seismic activity of Furnas Volcano. Because some of the surveyed waters are often drunk by the local population and tourists, our results are also useful in a public health perspective. We conclude that the measured radon activities do not pose any health problem, as they remain under the safety threshold (100 Bq/L) defined by the World Health Organization. The research performed allowed to define the radon background for each one of the groundwater discharges sampled and to identify the environmental parameters that can influence the radon concentration in the groundwater of Furnas Volcano, allowing more easily to identify a future reactivation of this volcanic system.

  3. Natural air ventilation in underground galleries as a tool to increase radon sampling volumes for geologic monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eff-Darwich, Antonio [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Instituto de Astrofisica de Canarias, c/Via Lactea s/n, 38205 La Laguna, Tenerife (Spain)], E-mail: adarwich@ull.es; Vinas, Ronaldo [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Soler, Vicente [Estacion Volcanologica de Canarias, IPNA-CSIC, Av. Astrofisico Francisco Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Nuez, Julio de la; Quesada, Maria L. [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain)

    2008-09-15

    A simple numerical model was implemented to infer airflow (natural ventilation) in underground tunnels from the differences in the temporal patterns of radon, {sup 222}Rn, concentration time-series that were measured at two distant points in the interior of the tunnels. The main purpose of this work was to demonstrate that the installation of radon monitoring stations closer to the entrance of the tunnels was sufficient to remotely analyse the distribution of radon concentration in their interiors. This could ease the monitoring of radon, since the effective sampling volume of a single monitoring station located closer to the entrance of a tunnel is approximately 30,000 times larger than the sampling volume of a sub-soil radon sensor. This methodology was applied to an underground gallery located in the volcanic island of Tenerife, Canary Islands. This island constitutes an ideal laboratory to study the geo-dynamical behaviour of radon because of the existence of a vast network of galleries that conforms the main water supply of the island.

  4. Radon control systems in existing and new construction: a review.

    Science.gov (United States)

    Rahman, Naureen Mahbub; Tracy, Bliss L

    2009-08-01

    In support of the implementation of the new Canadian radon guideline, a comprehensive review of radon mitigation techniques used in countries around the world was undertaken, with particular emphasis on North America and Europe that have climates and construction techniques similar to Canada. The results of this review are presented here as an aid to administrators of radon control programmes, companies offering radon testing and mitigation services and other concerned parties, both in Canada and elsewhere, who are facing issues of implementing a radon control strategy. A wide variety of radon mitigation strategies have been employed worldwide and all have achieved some success in reducing radon concentrations. Generally, active mitigation techniques involving physical alterations to a house (e.g. sub-slab depressurisation) are more effective in achieving a sustained and substantial radon reduction than passive techniques (e.g. improved ventilation or sealing of cracks). To a large extent, the choice of an optimal mitigation strategy will depend on the building type, soil conditions and climate. Radon levels should be measured at periodic intervals after remediation, perhaps once every 5 y, to ensure that concentrations continue to remain at acceptable levels.

  5. Construction and measurements of a vacuum-swing-adsorption radon-mitigation system

    Energy Technology Data Exchange (ETDEWEB)

    Schnee, R. W.; Bunker, R.; Ghulam, G.; Jardin, D.; Kos, M.; Tenney, A. S. [Department of Physics, Syracuse University, Syracuse, NY 13244 (United States)

    2013-08-08

    Long-lived alpha and beta emitters in the {sup 222}Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double beta decay, and in screening detectors. In order to reduce backgrounds from radon-daughter plate-out onto the wires of the Beta Cage during its assembly, an ultra-low-radon cleanroom is being commissioned at Syracuse University using a vacuum-swing-adsorption radon-mitigation system. The radon filter shows ∼20× reduction at its output, from 7.47±0.56 to 0.37±0.12 Bq/m{sup 3}, and the cleanroom radon activity meets project requirements, with a lowest achieved value consistent with that of the filter, and levels consistently < 2 Bq/m{sup 3}.

  6. Soil-gas radon concentration monitoring in an active granite quarry from Central Portugal

    Science.gov (United States)

    Neves, Luís.; Barbosa, Susana; Pereira, Alcides; Aumento, Fabrizio

    2010-05-01

    This study was carried out in an active quarry located nearby the town of Nelas (Central Portugal), with the primary objective of assessing the effect of regular explosions on soil-gas radon concentrations. Here, a late-orogenic Hercynian porphyritic biotite granite occurs and is exploited for the production of high quality aggregates for different building purposes. This granite is part of the Beiras batholiths, being a geochemically moderately evolved rock, slightly peraluminous, and widely known by the frequent occurrence of associated uranium mineralizations. In fact, more than 4000t of U3O8 was produced from 60 mines of the Beiras region in the last century, over a wide area of more than 10.000 km2, and thousands of anomalies related with the local accumulation of uranium in fault filling materials, metasedimentary enclaves and doleritic veins were recognized during prospecting works. The heterogeneity of uranium distribution in this rock is reflected at the test site; indeed, a gamma ray survey shows that some of the faults that occur in the quarry are slightly mineralized. A total of 7 radon monitoring stations were implemented in the quarry, at a typical depth comprised between 1 and 2 meters, in holes drilled for the purpose. Aware RM-70 pancake GM detectors were used, sensitive to alpha, beta and gamma/X-rays above 10 keV, connected to palmtop computers for data registration (1 minute interval) and power supplied by batteries. Monitoring was carried out during 6 months, in Spring/Summer conditions and the exact time of each explosion was registered manually. Several problems of data loss and power supply affected the stations during the experiment, leading to discontinuities in the records. Still the available data showed important differences in the soil-gas radon concentrations between stations, which can be explained by the heterogeneity of uranium distribution in the rock and increased local permeability. Furthermore, all stations showed a clear daily

  7. Design and construction of a system to determine Radon-222 through alpha spectroscopy; Diseno y construccion de un sistema para determinar Radon-222 mediante espectroscopia alfa

    Energy Technology Data Exchange (ETDEWEB)

    Bonifacio M, J. [Universidad Autonoma del Estado de Mexico. Facultad de Quimica. Toluca (Mexico)

    1991-12-31

    The purpose of this work consists in the design a radon-222 gas measurement system utilizing a surface barrier detector with the objective to obtain a more accurate measurement for this isotope through an alpha particle spectrum and so to address as to avoid the activity influence of the descendants of short half-life, which are too beta particles emitters, already other methods it must be correction series to obtain the real value of radon activity. Here are presented the general properties properties of radon, the experimental part description indicating the design to measure the radon-222 gas and its parts, as well as too the standard separation of radium-226 starting from carnotite mineral. Finally, it is presented the results obtained with a discussion about it. (Author) results obtained with a discussion about it. (Author)

  8. Description of the behavior of an aquifer by using continuous radon monitoring in a thermal spa

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Carlos, E-mail: sainzc@unican.es; Rábago, Daniel; Fuente, Ismael; Celaya, Santiago; Quindós, Luis Santiago

    2016-02-01

    Radon ({sup 222}Rn) levels in air and water have been analyzed continuously for almost a year in Las Caldas de Besaya thermal spa, north Spain. Radon is a naturally occurring noble gas from the decay of radium ({sup 226}Ra) both constituents of radioactive uranium 238 series. It has been recognized as a lung carcinogen by the World Health Organization (WHO) and International Agency for Research on Cancer (IARC). Furthermore the Royal Decree R.D 1439/2010 of November, 2010 establishes the obligation to study occupational activities where workers and, where appropriate, members of the public are exposed to inhalation of radon in workplaces such as spas. Together with radon measures several physico-chemical parameters were obtained such as pH, redox potential, electrical conductivity and air and water temperature. The devices used for the study of the temporal evolution of radon concentration have been the RTM 2100, the Radon Scout and gamma spectrometry was complementarily used to determine the transfer factor of the silicone tubes in the experimental device. Radon concentrations obtained in water and air of the spa are high, with an average of 660 Bq/l and 2900 Bq/m{sup 3} respectively, where water is the main source of radon in the air. Radiation dose for workers and public was estimated from these levels of radon. The data showed that the thermal processes can control the behavior of radon which can be also influenced by various physical and chemical parameters such as pH and redox potential. - Highlights: • Radon in water is the major source of indoor air radon concentration in thermal facilities. • Radon in water has been used to characterize the origin of water used for treatments in a spa. • Preliminary dose assessment from radon exposure has been performed.

  9. ASSESSMENT PROTOCOLS - DURABILITY OF PERFORMANCE OF A HOME RADON REDUCTION SYSTEM FOR SUB-SLAB DEPRESSURIZA- TION SYSTEMS

    Science.gov (United States)

    This handbook contains protocols that compare the immediate performance of subslab depressurization (SSD) mitigation system with performance months or years later. These protocols provide a methodology to test SSD radon mitigation systems in situ to determine long-term performanc...

  10. The radon; Le radon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-07-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings.

  11. Asphalt emulsion radon barrier systems for uranium mill tailings: an overview of the technology

    Energy Technology Data Exchange (ETDEWEB)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.; Gates, T.E.; Nelson, D.A.; Dunning, R.L.

    1984-03-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field tested at Grand Junction, Colorado. Results from laboratory and field tests indicate that this system is effective in reducing radon release to near-background levels (<2.5 pCi m/sup -2/s/sup -1/) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and analysis indicates that asphalt emulsion covers are cost-competitive with other cover systems. This report summarizes the technology for asphalt emulsion radon barrier systems. 59 references, 45 figures, 36 tables.

  12. Conversion of an Alpha CAM Monitor of Victoreen calibrated of factory for plutonium in a measurement monitor of radon in the atmosphere; Conversion de un monitor Alpha CAM de la Victoreen calibrado de fabrica para plutonio en un monitor para medicion de radon en la atmosfera

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico)

    2004-07-01

    It is presented in this work the conversion of a monitor ALPHA CAM of the monitor Victoreen gauged of it manufactures for plutonium in a monitor for radon mensuration in the atmosphere. Those units in that the radon measures are expressed are: peak curies/unit of volume of air to sampling. This way one has to gauge and to supplement the software and the parts that the old one monitor for plutonium. It requires. This task implies: a) To calibrate and to determine the efficiency of the detector of accustomed to state of 1700 mm{sup 2} for alpha particles coming from the radioactive series of the radon. b) to connect in series and to calibrate a flow measurer of air in it lines with the detector. Measures are presented of the ambient air and other places of the the historical area of the city of Puebla obtained with the team Converted ALPHA-CAM. (Author)

  13. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  14. Monitoring the radon flux from gold-mine dumps by gamma-ray mapping

    NARCIS (Netherlands)

    Lindsay, R; de Meijer, RJ; Maleka, PP; Newman, RT; Motlhabane, TGK; de Villiers, D

    The exhalation of radon from the large mine dumps at the gold mines in South Africa is a potential health hazard. Determination of radon fluxes from these dumpsites is problematic due to the scatter in the data in time and place and the cost involved in getting a representative sample. gamma-ray

  15. Radon in Groundwater of the Northeastern Gran Canaria Aquifer

    National Research Council Canada - National Science Library

    Hector Alonso; Tatiana Cruz-Fuentes; Jesús G Rubiano; Jonay Gonzalez-Guerra; María del Carmen Cabrera; Miguel A Arnedo; Alicia Tejera; Alejandro Rodríguez-Gonzalez; Francisco J Perez-Torrado; Pablo Martel

    2015-01-01

    ... (Canary Islands, Spain) utilizing a closed loop system consisting of an AlphaGUARD monitor that measures radon activity concentration in the air by means of an ionization chamber, and an AquaKIT set that transfers dissolved...

  16. Development of Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL in the Subsurface

    Energy Technology Data Exchange (ETDEWEB)

    Brian M. Davis; Lewis Semprini; Jonathan Istok

    2003-02-27

    Naturally occurring 222-radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and non-contaminated portions of an aquifer. During a push-pull test, a known volume of test solution (radon-free water containing a conservation tracer) is first injected (''pushed'') into a well; flow is then reversed and the test solution/groundwater mixture is extracted (''pulled'') from the same well. In the presence of NAPL radon transport is retarded relative to the conservative tracer. Assuming linear equilibrium partitioning, retardation factors for radon can be used to estimate NAPL saturations.The utility of this methodology was evaluated in laboratory and field settings.

  17. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  18. Description of the behavior of an aquifer by using continuous radon monitoring in a thermal spa.

    Science.gov (United States)

    Sainz, Carlos; Rábago, Daniel; Fuente, Ismael; Celaya, Santiago; Quindós, Luis Santiago

    2016-02-01

    Radon ((222)Rn) levels in air and water have been analyzed continuously for almost a year in Las Caldas de Besaya thermal spa, north Spain. Radon is a naturally occurring noble gas from the decay of radium ((226)Ra) both constituents of radioactive uranium 238 series. It has been recognized as a lung carcinogen by the World Health Organization (WHO) and International Agency for Research on Cancer (IARC). Furthermore the Royal Decree R.D 1439/2010 of November, 2010 establishes the obligation to study occupational activities where workers and, where appropriate, members of the public are exposed to inhalation of radon in workplaces such as spas. Together with radon measures several physico-chemical parameters were obtained such as pH, redox potential, electrical conductivity and air and water temperature. The devices used for the study of the temporal evolution of radon concentration have been the RTM 2100, the Radon Scout and gamma spectrometry was complementarily used to determine the transfer factor of the silicone tubes in the experimental device. Radon concentrations obtained in water and air of the spa are high, with an average of 660 Bq/l and 2900 Bq/m(3) respectively, where water is the main source of radon in the air. Radiation dose for workers and public was estimated from these levels of radon. The data showed that the thermal processes can control the behavior of radon which can be also influenced by various physical and chemical parameters such as pH and redox potential. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. RECOMMENDED SUB-SLAB DEPRESSURIZATION SYSTEMS DESIGN STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    Science.gov (United States)

    The report recommends sub-slab depressurization systems design criteria to the State of Florida's Department of Community Affairs for their building code for radon resistant houses. Numerous details are set forth in the full report. Primary criteria include: (1) the operating soi...

  20. Monitoring radon emission anomalies at Stromboli Island as a tracer of eruptive events and “near field” earthquakes

    Directory of Open Access Journals (Sweden)

    Cigolini C.

    2012-04-01

    Full Text Available Radon emission from soil at Stromboli Island has been monitored since 2002 utilizing a network of 25 stations and exposing two kinds of detectors: E-PERM and calibrated track-etches (LR115. We present and discuss the data from 2002 to 2007, thus including the last two major eruptive cycles. Earthquake-volcano interactions were detected providing evidence that radon emissions are somehow related to the occurrence of regional earthquakes. Single deep earthquakes related to active subduction, such as Salina event (ML = 5.1 of May 5, 2004, may be capable of increasing the ascent of geothermal fluids due to the passage of seismic waves. In addition, we observed major eruptions at Stromboli were preceded by anomalies that occurred at three summit stations that reached values above 20000 Bq m−3 : this is considered an anomalous value and could be regarded, under particular environmental conditions, as a potential precursory signal of a change in volcanic activity.

  1. Atmospheric radon: origin and transfer

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Tamez, E.; Pena, P.; Gaso, I. [Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico); Mireles, F.; Davila, I.; Quirino, L. [Universidad Autonoma de Zacatecas (Mexico). Centro Regional de Estudios Nucleares

    1994-12-31

    Atmospheric indoor and outdoor radon surveys have been performed in several locations of Mexico. In order to estimate the radon transfer from different origins to the atmosphere, soil and ground water, together with the exhalation rate from bare and coated building materials have also been studied. The radon detection was performed with SSNTD, an automatic silicon-based radon monitor and the liquid scintillation technique. The results from several years of monitoring indicate that the atmospheric radon behaviour is different for the countryside as compared with more complex inhabited regions; transfer from soil being inhibited by the specific structures of the cities. The effect of wall coatings reduced from 50% to 90% the radon exhalation from bare building materials. A low radon content was observed in the ground water samples studied. (Author).

  2. Geographical information system for radon gas from soil measurement; Il sistema informativo territoriale per la valutazione del potenziale di esalazione di radon dal suolo

    Energy Technology Data Exchange (ETDEWEB)

    Orlando, P.; Amici, M.; Altieri, A.; Massari, P.; Miccadei, E.; Onofri, A.; Orlando, C.; Paolelli, C.; Paron, P.; Perticaroli, P.; Piacentini, T.; Silvestri, C. [Milan Univ. Sacro Cuore, Milan (Italy). Servizio Centralizzato Radioisotopi; Belli, M.; Marchetti, A.; Petrocchi, A.; Rosamilia, S.; Serva, L.; Singh, G.; Tommasino, L. [Agenzia Nazionale per la Protezione dell' Ambiente, Rome (Italy); Minach, L.; Verdi, L. [Agenzia Provinciale per la Protezione dell' Ambiente, Bolzano (Italy); Bertolo, A.; Trotti, F. [Agenzia Regionale per la Protezione dell' Ambiente, Regione Veneto (Italy)

    2000-07-01

    The working program foresees the realization of an geographical information system for the check in field of the geological parameters and determination of uranium and radium contents in various type of rocks. It is here also pointed out a measuring method for radon concentration in soil. [Italian] In questo documento viene presentato il lavoro svolto fino ad oggi: dalla definizione dei parametri geologici ritenuti piu' significativi per la presenza di radon nel suolo e dalle misure in campo e in laboratorio, fino alla realizzazione del Sistema Informativo Territoriale (SIT) per la gestione dei suddetti parametri. Nel primo capitolo sono descritte le caratteristiche del radon, dal punto di vista chimico-fisico e geologico, per introdurre i criteri adottati nella scelta dei paramentri geologici e del loro peso per la valutazione del PERS (Potenziale di Esalazione Radon dal Suolo). Il secondo capitolo descrive il progetto in generale, mentre i successivi capitoli descrivono piu' in dettaglio la parte informatica e quella delle indagini sperimentali.

  3. LARGE BUILDING RADON MANUAL

    Science.gov (United States)

    The report summarizes information on how bilding systems -- especially the heating, ventilating, and air-conditioning (HVAC) system -- inclurence radon entry into large buildings and can be used to mitigate radon problems. It addresses the fundamentals of large building HVAC syst...

  4. Does balneotherapy with low radon concentration in water influence the endocrine system? A controlled non-randomized pilot study.

    Science.gov (United States)

    Nagy, Katalin; Berhés, István; Kovács, Tibor; Kávási, Norbert; Somlai, János; Bender, Tamás

    2009-08-01

    Radon bath is a well-established modality of balneotherapy for the management of degenerative musculoskeletal disorders. The present study was conducted to ascertain whether baths of relatively low (80 Bq/l) radon concentration have any influence on the functioning of the endocrine system. In the study, a non-randomized pilot study, 27 patients with degenerative musculoskeletal disorders received 30-min radon baths (of 31-32 degrees C temperature and 80 Bq/l average radon concentration) daily, for 15 days. Twenty-five patients with matching pathologies were subjected to balneotherapy according to the same protocol, using thermal water with negligible radon content (6 Bq/l). Serum thyroid stimulating hormone, prolactin, cortisol, adrenocorticotropic hormone, and dehydroepiandrosterone levels were measured before and after a balneotherapy course of 15 sessions. Comparison of the accumulated data using the Wilcoxon test did not reveal any significant difference between pre- and post-treatment values or between the two patient groups. It is noted that while the beneficial effects of balneotherapy with radon-containing water on degenerative disorders is widely known, only few data have been published in the literature on its effect on endocrine functions. The present study failed to demonstrate any substantial effect of thermal water with relatively low radon content on the functioning of the endocrine system.

  5. Development of a radon chamber and measurement of the radon solubility in tissues; Entwicklung einer Radonkammer und Messung der Radonloeslichkeit in Gewebe

    Energy Technology Data Exchange (ETDEWEB)

    Maier, Andreas

    2015-04-22

    Every year thousands of patients with inflammatory diseases of the musculoskeletal system undergo radon therapy, but the molecular mechanism and the risk of this therapy are not understood. To study the effects of radon exposure in vitro and in vivo we constructed a radon exposure chamber in the framework of the GREWIS project. With this device we are able to expose samples under controlled and reproducible conditions including the radon galleries in Austria and Germany. Adjustable parameters are radon activity-concentration, temperature, humidity and exposure time. These parameters are permanently monitored and controlled. During experiments with cell cultures it is also possible to adjust the CO{sub 2}-concentration. In addition, experiments with mice can be performed with this setup. To measure the radon kinetics in different types of tissue we exposed tissue samples like fat or muscle and mice in the radonchamber. Afterwards we measured the -spectra of the short living radon decay products lead-214 and bismuth-214 in the exposed samples with a HPGe-Detector. We recorded the spectra at different time points after exposure and calculated the initial amount of radon at the end of the exposure period in the sample and investigated the diffusion of the radon out of it. We compared the results from different types of tissue but also activated coal. In an activated coal sample the radon is bound to it via Van-der-Waals-force and the decay spectra are governed by the life time of the bound radon (3,8 days). In contrast in the biological samples the primary radon diffuses out of the samples in less than 20 minutes and the spectra follow the kinetics of the decay of the daughter products. These measurements where performed for the first time under therapy conditions like in radon galleries and also with higher radon concentration. In our experiments we could see an enhanced accumulation of radon and its decay products in fatty tissue compared to muscle tissue. Also in

  6. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector.

    Science.gov (United States)

    Rehman, Fazal-ur; Jamil, K; Zakaullah, M; Abu-Jarad, F; Mujahid, S A

    2003-01-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques have been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny (218Po and 214Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.

  7. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Fazal-ur- E-mail: fazalr@kfupm.edu.sa; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A

    2003-07-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ({sup 218}Po and {sup 214}Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.

  8. Radon 10 x 10 project: Implantation of geographic information systems in studies of radon in homes and geology catalans; Proyecto radon 10x10: aplicacion de los sistemas de informacion geografica en estudios de radon y geologia en viviendas catalanas

    Energy Technology Data Exchange (ETDEWEB)

    Amado Sanjuan, J. L.; Bach Plaza, J.; Baixeras divar, C.; Font Guiteras, L. L.; Moreno Balta, V.

    2013-07-01

    This methodology provides a useful tool to establish relationships between different data in order to identify areas in which to assess the radiological risk that represents radon in the Catalan population and gagging. (Author)

  9. Indoor radon monitoring in Northern Iran using passive and active measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hadad, Kamal [Department of Nuclear Engineering, Shiraz University, Shiraz 7134851154 (Iran, Islamic Republic of)]. E-mail: hadadk@shirazu.ac.ir; Doulatdar, R. [Shiraz University Nuclear Safety Research Center, Shiraz 7134851154 (Iran, Islamic Republic of); Mehdizadeh, S. [Department of Nuclear Engineering, Shiraz University, Shiraz 7134851154 (Iran, Islamic Republic of)

    2007-06-15

    In this work we present the results of a 2-year survey of indoor radon variations in four cities of Lahijan, Ardabil, Sar-Ein and Namin in North and Northwest Iran. We used both passive and active measurements by solid state nuclear track detectors (SSNTDs) with CR-39 polycarbonate and PRASSI Portable radon Gas Surveyor. A total of 1124 samplers in Lahijan, Ardabil, Sar-Ein and Namin were installed. Sampling frequency was seasonal and sampling locations were randomly chosen based on dwelling structures, floors, geological formations, elevation and temperature variation parameters. For quality assurance, 281 active measurements and double sampling were carried out. Based on our results and the results of previous surveys, Ardabil and Lahijan have the second and third highest radon concentration in Iran, respectively (Ramsar is first). The average radon concentration during the year in Lahijan, Ardabil, Sar-Ein and Namin were 163, 240, 160 and 144 Bq/m{sup 3} with medians of 160, 168, 124 and 133 Bq/m{sup 3}, respectively. These concentrations give rise to annual effective doses of 3.43 mSv/y for Lahijan and 5.00 mSv/y for Ardabil. The maximum recorded concentration was 2386 Bq/m{sup 3} during winter in Ardabil and the minimum concentration was 55 Bq/m{sup 3} during spring in Lahijan. Relationships between radon concentration and building materials and room ventilation were also studied. The dosimetry calculations showed that these four cities could be categorized as average natural radiation zones. The correlation coefficients relating warm and cold season radon variation data were obtained.

  10. Radon in Groundwater of the Northeastern Gran Canaria Aquifer

    OpenAIRE

    Héctor Alonso; Tatiana Cruz-Fuentes; Jesús G. Rubiano; Jonay González-Guerra; María del Carmen Cabrera; Miguel A. Arnedo; Alicia Tejera; Alejandro Rodríguez-Gonzalez; Francisco J. Pérez-Torrado; Pablo Martel

    2015-01-01

    222Rn has been detected in 28 groundwater samples from the northeast of Gran Canaria (Canary Islands, Spain) utilizing a closed loop system consisting of an AlphaGUARD monitor that measures radon activity concentration in the air by means of an ionization chamber, and an AquaKIT set that transfers dissolved radon in the water samples to the air within the circuit. Radon concentration in the water samples studied varies between 0.3 and 76.9 Bq/L. Spanish radiological protection regulations lim...

  11. High radon levels in subterranean environments: monitoring and technical criteria to ensure human safety (case of Castañar cave, Spain).

    Science.gov (United States)

    Alvarez-Gallego, Miriam; Garcia-Anton, Elena; Fernandez-Cortes, Angel; Cuezva, Soledad; Sanchez-Moral, Sergio

    2015-07-01

    Castañar cave contains the highest radon gas ((222)Rn) concentration in Spain with an annual average of 31.9 kBq m(-)(3). Seasonal variations with summer minimums and maximum values in fall were recorded. The reduction of air-filled porosity of soil and rock by condensation or rainfalls hides the radon exchange by gas diffusion, determining this seasonal stair-step pattern of the radon activity concentration in underground air. The effective total dose and the maximum hours permitted have been evaluated for the guides and public safety with a highly detailed radon measurement along 2011 and 2012. A network of 12 passive detectors (kodalphas) has been installed, as well as, two radon continuous monitoring in the most interesting geological sites of the subterranean environment. A follow up of the recommended time (max. 50 min) inside the underground environment has been analysed since the reopen to public visitors for not surpassing the legal maximum effective dose for tourists and guides. Results shown that public visitors would receive in fall a 12.1% of the total effective dose permitted per visit, whereas in summer it is reduced to 8.6%, while the cave guide received a total effective dose of 6.41 mSv in four months. The spatial radon maps allow defining the most suitable touristic paths according to the radon concentration distribution and therefore, appropriate fall and summer touristic paths are recommended. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Design and construction of a system for determining Radon-222 through Alpha spectroscopy; Diseno y construccion de un sistema para determinar Radon-222 mediante Espectroscopia alfa

    Energy Technology Data Exchange (ETDEWEB)

    Bonifacio, J.; Iturbe, J.L

    1992-02-15

    The study of the present work consists on designing a system to measure gas {sup 222} Rn, using a surface barrier detector, in order to obtaining a more accuracy measure of this isotope by means of an alpha particle spectra and thus to try to avoid the influence of the radioactivity of the isotope descendants of short half life, which are also emitting of alpha particles, since by other methods its should make a series of corrections to obtain the real value of the radon activity. (Author)

  13. The Assessment of the Integrated Antioxidant System of the Body in the Course of Radon Therapy: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Jadwiga Kuciel-Lewandowska

    2018-01-01

    Full Text Available Introduction. The sources of Reactive Oxidative Species (ROS in the organism are the respiratory processes occurring in cells catalyzed by different enzymes. Operation of ROS is balanced by antioxidants, the compounds; although present in low concentrations, they significantly inhibit the degree of oxidation of particular molecules. The Aim of the Study. The aim of this study was to assess the changes in the integrated antioxidant system under the influence of radon therapy in osteoarthritis patients. Material and Methods. Observation included 35 patients suffering from degenerative joints and disc disease (mean age 56.5 years undergoing radon water therapy and control group that consisted of 15 osteoarthritis patients (mean age 54.2 without contact with radon water. Before therapy and after 18 days of treatment, serum total antioxidant status (TAS was assessed with the use of standard colorimetric assay. Results. In the study group, we observed trends to increase TAS concentration, whereas, in the control group, TAS concentration was decreasing. Conclusions. (1 Radon waters treatment influenced the level of TAS of osteoarthritis patients treated with the radon water. (2 The change in TAS concentrations in the study group may be the result of low doses of ionizing radiation, but further studies on larger patient’s groups are demanded. This study is registered with number NCT03274128.

  14. Radon and thoron concentrations in public workplaces in Brisbane, Australia.

    Science.gov (United States)

    Alharbi, Sami H; Akber, Riaz A

    2015-06-01

    Radon and thoron are radioactive gases that can emanate from soil and building materials, and it can accumulate in indoor environments. The concentrations of radon and thoron in the air from various workplace categories in Brisbane, Australia were measured using an active method. The average radon and thoron concentrations for all workplace categories were 10.5 ± 11.3 and 8.2 ± 1.4 Bq m(-3), respectively. The highest radon concentration was detected in a confined area, 86.6 ± 6.0 Bq m(-3), while the maximum thoron level was found in a storage room, 78.1 ± 14.0 Bq m(-3). At each site, the concentrations of radon and thoron were measured at two heights, 5 cm and 120 cm above the floor. The effect of the measurement heights on the concentration level was significant in the case of thoron. The monitoring of radon and thoron concentrations showed a lower radon concentration during work hours than at other times of the day. This can be attributed to the ventilation systems, including the air conditioner and natural ventilation, which normally operate during work hours. The diurnal variation was less observed in the case of thoron, as the change in its concentration during and after the working hours was insignificant. The study also investigated the influence of the floor level and flooring type on indoor radon and thoron concentrations. The elevated levels of radon and thoron were largely found in basements and ground floor levels and in rooms with concrete flooring. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Performance analysis of a finite radon transform in OFDM system under different channel models

    Energy Technology Data Exchange (ETDEWEB)

    Dawood, Sameer A.; Anuar, M. S.; Fayadh, Rashid A. [School of Computer and Communication Engineering, Universiti Malaysia Perlis (UniMAP) Pauh Putra, 02000 Arau, Parlis (Malaysia); Malek, F.; Abdullah, Farrah Salwani [School of Electrical System Engineering, Universiti Malaysia Perlis (UniMAP) Pauh Putra, 02000 Arau, Parlis (Malaysia)

    2015-05-15

    In this paper, a class of discrete Radon transforms namely Finite Radon Transform (FRAT) was proposed as a modulation technique in the realization of Orthogonal Frequency Division Multiplexing (OFDM). The proposed FRAT operates as a data mapper in the OFDM transceiver instead of the conventional phase shift mapping and quadrature amplitude mapping that are usually used with the standard OFDM based on Fast Fourier Transform (FFT), by the way that ensure increasing the orthogonality of the system. The Fourier domain approach was found here to be the more suitable way for obtaining the forward and inverse FRAT. This structure resulted in a more suitable realization of conventional FFT- OFDM. It was shown that this application increases the orthogonality significantly in this case due to the use of Inverse Fast Fourier Transform (IFFT) twice, namely, in the data mapping and in the sub-carrier modulation also due to the use of an efficient algorithm in determining the FRAT coefficients called the optimal ordering method. The proposed approach was tested and compared with conventional OFDM, for additive white Gaussian noise (AWGN) channel, flat fading channel, and multi-path frequency selective fading channel. The obtained results showed that the proposed system has improved the bit error rate (BER) performance by reducing inter-symbol interference (ISI) and inter-carrier interference (ICI), comparing with conventional OFDM system.

  16. Flight Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase I project will develop the Flight System Monitor which will use non-intrusive electrical monitoring (NEMO). The electronic system health of...

  17. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  18. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Scopingsreport Radon

    NARCIS (Netherlands)

    Blaauboer RO; Vaas LH; Hesse JM; Slooff W

    1989-01-01

    Dit scopingsrapport vormt een onderdeel van de voorbereiding tot het opstellen van het basisdocument radon. Het doel van dit rapport is het algemene kennisniveau van de deelnemers aan de scopingsbijeenkomst aangaande radon op eenzelfde peil te brengen en discussie- en beslispunten inzake de

  20. Impact of radon and combinatory radon/carbon dioxide spa on pain and hypertension: Results from the explorative RAD-ON01 study.

    Science.gov (United States)

    Rühle, Paul F; Klein, Gerhart; Rung, Tatjana; Tiep Phan, Hong; Fournier, Claudia; Fietkau, Rainer; Gaipl, Udo S; Frey, Benjamin

    2018-02-16

    Therapies with low doses of radon have beneficial effects on patients suffering from chronic painful degenerative and inflammatory diseases. We already showed that this is accompanied by systemic immune modulations. We here focus on pain reducing effects of very low doses of radon by adding carbon dioxide water and its impact on heart rate variability (HRV), blood pressure and free radicals. 100 patients receiving radon spa (1.200 Bq/l at 34°C or 600 Bq/l, 1 g/l CO 2 at 34°C) were monitored before and at three different time points after therapy. Individual pain perception was analyzed and the capability to process radicals. At each time point the hypertensive patients (n = 46) were examined over 24h for blood pressure and HRV. Long term pain reduction was observed in the majority of patients. A modulation of superoxide dismutase was identified, presumably representing a priming effect for lowering radiation stress. Further, lowering of blood pressure, especially in those patients who additionally received carbon dioxide, was seen. Radon did in particular impact on HRV implying lasting relaxation effects. Radon/carbon dioxide spa efficiently reduces pain. In particular, patients simultaneously suffering from painful and cardiovascular diseases should be treated by combination of radon and CO 2 .

  1. ERRICCA radon model intercomparison exercise

    DEFF Research Database (Denmark)

    Andersen, C.E.; Albarracín, D.; Csige, I.

    1999-01-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to morefundamental studies of radon transport. To ascertain ......, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommendedthat additional exercises are carried out....

  2. Validation of a geographic information system for the evaluation of the soil radon exhalation potential in South-Tyrol and Veneto, Italy.

    Science.gov (United States)

    Bertolo, A; Verdi, L

    2001-01-01

    The PERS (soil radon exhalation potential) project was promoted by ANPA (Italian Environmental Protection Agency) together with the Università Cattolica del Sacro Cuore of Rome: the aim was to produce a geographic information system allowing the discovery of regions with different radon exhalation potential starting from some territorial knowledge. Some environmental measurements were carried out within this project in selected areas in South-Tyrol and Veneto. The measurement of radon in springwater and groundwater as well as in soil gas plays a decisive role for the validation of the algorithm for computing the PERS. Along with technical aspects, a possible use of the PERS method by the Regional Environmental Protection Agencies and by other agencies is discussed with the scope of identifying radon prone areas, as stated in the Italian 'Decreto Legislativo' 26 May 2000, n. 241. Moreover the forecasting power of PERS regarding indoor radon concentration is analysed.

  3. Validation of a geographic information system for the evaluation of the soil radon exhalation potential in South-Tyrol and Veneto (Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Bertolo, A.; Verdi, L

    2001-07-01

    The PERS (soil radon exhalation potential) project was promoted by ANPA (Italian Environmental Protection Agency) together with the Universita Cattolica del Sacro Cuore of Rome: the aim was to produce a geographic information system allowing the discovery of regions with different radon exhalation potential starting from some territorial knowledge. Some environmental measurements were carried out within this project in selected areas in South-Tyrol and Veneto. The measurement of radon in springwater and groundwater as well as in soil gas plays a decisive role for the validation of the algorithm for computing the PERS. Along with technical aspects, a possible use of the PERS method by the Regional Environmental Protection Agencies and by other agencies is discussed with the scope of identifying radon prone areas, as stated in the Italian 'Decreto Legislativo' 26 May 2000, n. 241. Moreover the forecasting power of PERS regarding indoor radon concentration is analysed. (author)

  4. Simplified Monitoring System

    CERN Document Server

    Jelinskas, Adomas

    2013-01-01

    This project can be considered as a model for a simplified grid monitoring. In particular, I was creating a specific monitoring instance, which can be easily set up on a machine and, depending on an input information, automatically start monitoring services using Nagios software application. I had to automate the set up process and configuration of the monitoring system in order for the user to use it easily. I developed a script which automatically sets up the monitoring system, configures it and starts monitoring. I put the script, files and instructions in the repository 'https://git.cern.ch/web/?p=cosmic.git;a=summary' under the sub-directory called SNCG.

  5. Evaluation of radon adsorption characteristics of a coconut shell-based activated charcoal system for radon and thoron removal applications.

    Science.gov (United States)

    Karunakara, N; Sudeep Kumara, K; Yashodhara, I; Sahoo, B K; Gaware, J J; Sapra, B K; Mayya, Y S

    2015-04-01

    Radon ((222)Rn), thoron ((220)Rn), and their decay products contribute a major fraction (more than 50%) of doses received from ionisation radiation in public domain indoor environments and occupation environments such as uranium mines, thorium plants, and underground facilities, and are recognised as important radiological hazardous materials, which need to be controlled. This paper presents studies on the removal of (222)Rn and (220)Rn from air using coconut shell-based granular activated charcoal cylindrical adsorber beds. Experiments were conducted to evaluate the (222)Rn and (220)Rn adsorption characteristics, and the mitigation efficiency of coconut-based activated charcoal available in India. The performance parameters evaluated include breakthrough time (τ) and adsorption coefficient (K), and degassing characteristics of the charcoal bed of varying dimensions at different flow rates. While the breakthrough for (222)Rn occurred depending on the dimension of the adsorber bed and flow rates, for (220)Rn, the breakthrough did not occur. The breakthrough curve exhibited a stretched S-shape response, instead of the theoretically predicted sharp step function. The experiments confirm that the breakthrough time individually satisfies the quadratic relationship with respect to the diameter of the bed, and the linear relationship with respect to the length, as predicted in the theory. The K value varied in the range of 2.3-4.12 m(3) kg(-1) with a mean value of 2.99 m(3) kg(-1). The K value was found to increase with the increase in flow rate. Heating the charcoal to ∼ 100 °C resulted in degassing of the adsorbed (222)Rn, and the K of the degassed charcoal and virgin charcoal were found to be similar with no deterioration in performance indicating the re-usability of the charcoal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Anomalous radon concentration in a nuclear research facility

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar, M.; Pena, P., E-mail: miguel.balcazar@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-08-15

    Radon monitoring in more than 60 selected points were part of surveillance radiation activities in the nuclear center of Mexico; three major facilities were inspected, the TRIGA Mark III research reactor, the Tandem Van de Graaff Accelerator and the Pelletron electron Accelerator. During a major maintenance activities in the research reactor, the air extraction system was not functioning for more than a month causing of a radon build up exhaled from the massive concrete of the building, reaching concentrations in some places up to 2.1 kb m{sup -3}. The irradiation room at the Tandem Accelerator presented high radon concentrations up to nearly 5 kb m{sup -3}, manly in the trenches were pipes and electric wires are located, the radon source was identified as originated from small caves under the floor. Low radon concentrations were found inside a similar building where a Pelletron accelerator is located. The reasons for the abnormal radon concentrations and the mitigation actions to remove any risk for the worker are discussed in detail in this paper. (author)

  7. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  8. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  9. Earthquake forecasting studies using radon time series data in Taiwan

    Science.gov (United States)

    Walia, Vivek; Kumar, Arvind; Fu, Ching-Chou; Lin, Shih-Jung; Chou, Kuang-Wu; Wen, Kuo-Liang; Chen, Cheng-Hong

    2017-04-01

    For few decades, growing number of studies have shown usefulness of data in the field of seismogeochemistry interpreted as geochemical precursory signals for impending earthquakes and radon is idendified to be as one of the most reliable geochemical precursor. Radon is recognized as short-term precursor and is being monitored in many countries. This study is aimed at developing an effective earthquake forecasting system by inspecting long term radon time series data. The data is obtained from a network of radon monitoring stations eastblished along different faults of Taiwan. The continuous time series radon data for earthquake studies have been recorded and some significant variations associated with strong earthquakes have been observed. The data is also examined to evaluate earthquake precursory signals against environmental factors. An automated real-time database operating system has been developed recently to improve the data processing for earthquake precursory studies. In addition, the study is aimed at the appraisal and filtrations of these environmental parameters, in order to create a real-time database that helps our earthquake precursory study. In recent years, automatic operating real-time database has been developed using R, an open source programming language, to carry out statistical computation on the data. To integrate our data with our working procedure, we use the popular and famous open source web application solution, AMP (Apache, MySQL, and PHP), creating a website that could effectively show and help us manage the real-time database.

  10. Determination of the relationship between radon anomalies and earthquakes in well waters on the Akşehir-Simav Fault System in Afyonkarahisar province, Turkey.

    Science.gov (United States)

    Ali Yalım, Hüseyin; Sandıkcıoğlu, Ayla; Ertuğrul, Oğuz; Yıldız, Ahmet

    2012-08-01

    Radon concentrations were measured in water of 4 wells on the Akşehir-Simav Fault System (ASFS) in Afyonkarahisar province from August 2009 to September 2010 and the relationship between radon anomalies and earthquake magnitudes was examined. Anomalous decreases in radon concentrations in the wells were observed to precede the earthquakes of magnitudes ranging from 2.6 M to 3.9 M. The correlation coefficients (R(2)) were 0.79, 0.93, 0.98 and 0.90 for the wells from 1 to 4, respectively, indicating that radon minima and earthquake magnitude were well correlated and suggesting that the groundwater radon, when observed at suitable sites, can be a sensitive tracer for strain changes in crust associated with earthquake occurrences. The relationship between the two parameters can be further improved as additional radon anomalies precursor to possible large earthquakes are recorded in the wells located on the ASFS in the future. This study strongly suggests that the continuous observations of radon concentrations in well water, especially at well 3, should be carried forward. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  12. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  13. Validation and application of the methodology for analysis of radon concentration in the air through the technique of solid state nuclear track detectors (SSNTD)

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Caroline de [Pontificia Universidade Catolica de Minas Gerais (PUC-Pocos), Pocos de Caldas, MG (Brazil); Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas; Silva, Nivaldo Carlos da, E-mail: ncsilva@cnen.gov.b [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas

    2011-07-01

    Radon is a radioactive noble gas that occurs naturally in soil and could enter into residential. The decay products of radon are radioactive metals which, when inhaled, can be retained in the respiratory system, leading to an internal dose of radiation. The monitoring of radon levels in residences and workplaces is extremely important, since high concentrations of this gas can cause serious public health problems. This study analyzed the concentration of radon in the air in 94 work environments at the Laboratory of Pocos de Caldas - LAPOC/CNEN, including laboratories, administrative rooms, workshop, warehouse and guardhouse. The method employed in the monitoring was the technique of solid state nuclear track detectors, known as SSNTD. For calibration and validation of this method, controlled experiments were conducted in laboratory with specific instrumentation. The monitoring results indicated that most environments present radon concentrations above 100 Bq m{sup -3}, which is the reference level recommended by the World Health Organization. (author)

  14. Spatio-temporal variations of soil radon patterns around the Sea of Marmara

    Science.gov (United States)

    Passarelli, Luigi; Seyis, Cemil; Woith, Heiko

    2016-04-01

    Typically, the noble gas radon displays cyclic daily (S1), semidiurnal (S2) as well as seasonal variations in geological environments like soil air, groundwater, rock, caves, and tunnels. But there are also cases where theses cycles are absent. We present examples from a radon monitoring network of 21 sites around the Sea of Marmara. The works were carried out in the frame of MARsite, a project related to the EU supersite initiative (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417). Alpha-meters from the Canadian company alpha-nuclear are used to measure the radon concentration in counts per 15 minutes at a depth of 80 cm. The long-term average radon concentrations at 21 sites vary between 35 and 1,000 counts per 15 minutes. Typical seasonal variations are absent at more than 6 sites. Sites with seasonal variations have radon minima usually during winter (December to April), radon maxima during summer months (June to October). We carefully investigated radon time series for all the monitoring stations. We find that at some sites the empirical distribution of radon counts is clearly bimodal and in other bimodality is absent. In those stations we analysed the time series in different time intervals in order to highlight seasonal periodicity in the radon emission. The empirical distributions obtained by time-windowing of the radon signals results to be statistically different one another after applying a Kolmogorov-Smirnov test at significance level of 0.1. Usually the maxima in radon emission occur in summer time but, interestingly enough, two sites are characterized by radon maxima in winter periods. We further investigate the radon signals seeking for smaller scale periodicity. We calculated Fourier spectra of all 21 sites. Daily cycles are absent at 6 sites which is an unusual phenomenon. Daily cycles may disappear, if the local system is heavily

  15. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  16. Aerospace Systems Monitor Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I STTR project will demonstrate the Aerospace System Monitor (ASM). This technology transforms the power distribution network in a spacecraft or aircraft...

  17. Determination of radon gas and respirable ore dust concentrations ...

    African Journals Online (AJOL)

    This study has estimated the concentrations of radon gas and respirable ore dust in the Merelani underground tanzanite mines. Two different portable monitors were used to measure the radon gas and respirable ore dust concentrations respectively. The mean radon gas concentration (disintegrations per second per cubic ...

  18. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  19. Field validation of radon monitoring as a screening methodology for NAPL-contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Gonzalez, J.E.; Ortega, M.F.; Chacon, E.; Mazadiego, L.F. [Grupo de Geoquimica Ambiental, Universidad Politecnica de Madrid, E.T.S. Ingenieros de Minas, Alenza 4, 28003 Madrid (Spain); Miguel, E. de [Grupo de Geoquimica Ambiental, Universidad Politecnica de Madrid, E.T.S. Ingenieros de Minas, Alenza 4, 28003 Madrid (Spain)], E-mail: eduardo.demiguel@upm.es

    2008-09-15

    Screening methodologies aim at improving knowledge about subsurface contamination processes before expensive intrusive operations, i.e. drilling and core-sampling, well installation and development, sampling of groundwater and free-phase product, are implemented. Blind field tests carried out at a hydrocarbon storage and distribution center in NE Spain suggest that Rn monitoring can be effectively used to locate the boundaries of subsurface accumulations of NAPLs. Sixty seven measurements of Rn in soil air were performed with a SARAD RTM 2100 current-ionization alpha-particle spectrometer following a 10 m square grid. Reductions of {sup 222}Rn concentration above a pool of LNAPL due to the preferential partition of Rn into the organic phase were spatially analyzed and resolved to yield the surface contour of the NAPL source zone. This surface trace of the source zone agreed well with the extent and situation inferred from measurements of free-phase thickness taken at eight monitoring wells at the site. Moreover, the good repeatability (as measured by replicate measurements at the same sampling point) and spatial resolution of the technique suggest that the boundaries of the plume can be delineated at the sub-decametre level.

  20. Measurement of radon concentration in super-Kamiokande's buffer gas

    Science.gov (United States)

    Nakano, Y.; Sekiya, H.; Tasaka, S.; Takeuchi, Y.; Wendell, R. A.; Matsubara, M.; Nakahata, M.

    2017-09-01

    To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33 ± 0.07 mBq /m3 . In this article, we discuss the construction and calibration of this detector as well as results of its application to the measurement and monitoring of the buffer gas layer above Super-Kamiokande. In March 2013, the chilled activated charcoal system used to remove radon in the input buffer gas was upgraded. After this improvement, a dramatic reduction in the radon concentration of the supply gas down to 0.08 ± 0.07 mBq /m3 . Additionally, the Rn concentration of the in-situ buffer gas has been measured 28.8 ± 1.7 mBq /m3 using the new radon detector. Based on these measurements we have determined that the dominant source of Rn in the buffer gas arises from contamination from the Super-Kamiokande tank itself.

  1. Relationships between indoor radon concentrations, thermal retrofit and dwelling characteristics.

    Science.gov (United States)

    Collignan, Bernard; Le Ponner, Eline; Mandin, Corinne

    2016-12-01

    A monitoring campaign was conducted on a sample of more than 3400 dwellings in Brittany, France from 2011 to 2014. The measurements were collected using one passive dosimeter per dwelling over two months during the heating season, according to the NF ISO 11665-8 (2013) standard. Moreover, building characteristics such as the period of construction, construction material, type of foundation, and thermal retrofit were determined using a questionnaire. The final data set consisted of 3233 houses with the measurement results and the questionnaire answers. Multivariate linear regression models were applied to explore the relationships between the indoor radon concentrations and building characteristics, particularly the thermal retrofit. The geometric mean of the indoor radon concentration was 155 Bq m(-3) (with a geometric standard deviation of 3). The houses that had undergone a thermal retrofit had a higher average radon concentration than those that had not, which may have been due to a decrease in air permeability of the building envelope following rehabilitation work that did not systematically include proper management of the ventilation. Other building characteristics, primarily the building material and the foundation type, were associated with the indoor radon concentration. The indoor radon concentrations were higher in older houses built with granite or other stone, with a slab-on-grade foundation and without any ventilation system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Radon in Groundwater of the Northeastern Gran Canaria Aquifer

    Directory of Open Access Journals (Sweden)

    Héctor Alonso

    2015-05-01

    Full Text Available 222Rn has been detected in 28 groundwater samples from the northeast of Gran Canaria (Canary Islands, Spain utilizing a closed loop system consisting of an AlphaGUARD monitor that measures radon activity concentration in the air by means of an ionization chamber, and an AquaKIT set that transfers dissolved radon in the water samples to the air within the circuit. Radon concentration in the water samples studied varies between 0.3 and 76.9 Bq/L. Spanish radiological protection regulations limit the concentration of 222Rn for drinking water to 100 Bq/L, therefore the values obtained for all the analyzed samples are below this threshold. The hydrogeological study reveals a significant correspondence between the radon activity concentration and the material characteristics of the aquifer. For a selected group of samples with high radon concentrations, gross alpha activity has been determined to have values higher than the prescriptive screening level (0.1 Bq/L.

  3. Indoor Radon in Micro-geological Setting of an Indigenous Community in Canada: A Pilot Study for Hazard Identification

    Directory of Open Access Journals (Sweden)

    Atanu Sarkar

    2017-04-01

    Full Text Available Background: Radon is the second leading cause of lung cancer after smoking. In Canada, the health authorities have no access to comprehensive profile of the communities built over uranium-rich micro-geological settings. The present indoor radon monitoring guideline is unable to provide an accurate identification of health hazards due to discounting several parameters of housing characteristics. Objective: To explore indoor radon levels in a micro-geological setting known for high uranium in bedrock and to develop a theoretical model for a revised radon testing protocol. Methods: We surveyed a remote Inuit community in Labrador, located in the midst of uranium belt. We selected 25 houses by convenience sampling and placed electret-ion-chamber radon monitoring devices in the lowest levels of the house (basement/crawl space. The standard radon study questionnaire developed and used by Health Canada was used. Results: 7 (28% houses had radon levels above the guideline value (range 249 to 574 Bq/m3. Housing characteristics, such as floors, sump holes, ventilation, and heating systems were suspected for high indoor radon levels and health consequences. Conclusion: There is a possibility of the existence of high-risk community in a low-risk region. The regional and provincial health authorities would be benefited by consulting geologists to identify potentially high-risk communities across the country. Placing testing devices in the lowest levels provides more accurate assessment of indoor radon level. The proposed protocol, based on synchronized testing of radon (at the lowest level of houses and in rooms of normal occupancy and thorough inspection of the houses will be a more effective lung cancer prevention strategy.

  4. Indoor Radon in Micro-geological Setting of an Indigenous Community in Canada: A Pilot Study for Hazard Identification.

    Science.gov (United States)

    Sarkar, Atanu; Wilton, Derek Hc; Fitzgerald, Erica

    2017-04-01

    Radon is the second leading cause of lung cancer after smoking. In Canada, the health authorities have no access to comprehensive profile of the communities built over uranium-rich micro-geological settings. The present indoor radon monitoring guideline is unable to provide an accurate identification of health hazards due to discounting several parameters of housing characteristics. To explore indoor radon levels in a micro-geological setting known for high uranium in bedrock and to develop a theoretical model for a revised radon testing protocol. We surveyed a remote Inuit community in Labrador, located in the midst of uranium belt. We selected 25 houses by convenience sampling and placed electret-ion-chamber radon monitoring devices in the lowest levels of the house (basement/crawl space). The standard radon study questionnaire developed and used by Health Canada was used. 7 (28%) houses had radon levels above the guideline value (range 249 to 574 Bq/m 3 ). Housing characteristics, such as floors, sump holes, ventilation, and heating systems were suspected for high indoor radon levels and health consequences. There is a possibility of the existence of high-risk community in a low-risk region. The regional and provincial health authorities would be benefited by consulting geologists to identify potentially high-risk communities across the country. Placing testing devices in the lowest levels provides more accurate assessment of indoor radon level. The proposed protocol, based on synchronized testing of radon (at the lowest level of houses and in rooms of normal occupancy) and thorough inspection of the houses will be a more effective lung cancer prevention strategy.

  5. Nekton Interaction Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    2017-03-15

    The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonar devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).

  6. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  7. Wearable Health Monitoring Systems

    Science.gov (United States)

    Bell, John

    2015-01-01

    The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

  8. HANDBOOK: SUB-SLAB DEPRESSURIZATION FOR LOW PERMEABILITY FILL MATERIAL DESIGN AND INSTALLATION OF A HOME RADON REDUCTION SYSTEM

    Science.gov (United States)

    Radon, a radioactive gas, comes from the natural decay of uranium. It moves to the earth's surface through tiny openings and cracks in soil and rocks. In outdoor air, radon is diluted to such low concentrations that it is usually nothing to worry about. However, radon can accumul...

  9. Alpha radioactivity monitoring related to Radon-222 in water from wells in metropolitan area of Curitiba (PR), Brazil; Monitoramento da radioatividade alfa relacionada ao radonio-222 em aguas de pocos da regiao metropolitana de Curitiba (PR)

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Janine Nicolosi; Paschuk, Sergei Anatolyevich; Kappke, Jaqueline; Claro, Flavia Del; Perna, Allan Felipe Nunes; Reque, Marilson, E-mail: janine_nicolosi@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Denyak, Valeriy; Schelin, Hugo Reuters [Instituto de Pesquisa Pele Pequeno Principe (IPPPP), Curitiba, PR (Brazil); Rocha, Zildete; Santos, Talita Oliveira [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-04-15

    This research objective was to assess the level of randon-222 concentration in well water of the metropolitan region of Curitiba, Parana. Current work presents the results of indoor {sup 222}Rn activity ground water samples from artesian wells from aquifers of the region. The studies of radon activity in water were performed using the radon detector AlphaGUARD. The calculations of initial radon activity in water were done considering the {sup 222}Rn decay correction as well as equilibrium level of {sup 222}Rn and {sup 226}Ra observed after 30 days of measurements. Obtained results show that about 70% of measured activity levels of {sup 222}Rn are higher than the recommended value of 11.1 Bq.L{sup -1}, which represent the risk for the human health associated with this radionuclide. The case study showed that previous measurements of radon are recommended for a construction project is implemented. In this case, it is observed that the radon concentrations decrease about 56% in the first water tank and 83% in the second water tank over the well. This fact shows that the actions for mitigation of radon are viable and do not require major modifications to the usual systems of construction. (author)

  10. A study on heavy radioactive pollution: Radon and Radium in streams and drinking water of Ramsar region by measured Prassi system

    Directory of Open Access Journals (Sweden)

    S Mohammadi

    2012-03-01

    Full Text Available  Inhalation of radon gas 222Rn, which is a decay product of 226Ra, and its decay products accounts for typically about half of the effective doses received by public from all natural sources of ionizing radiation. Radon alpha particles can initiate a series of molecular and cellular events that culminates in the development of lung and other cancers. Also, 226Ra in the environment is widely distributed, being present in various concentrations in waters, soils and rocks. When radium is ingested, the majority of material is rapidly excreted. However, since radium is chemically similar to calcium, a significant fraction is absorbed into the bloodstream and deposited mainly in the skeleton. So, presence of these radioactive contaminants in water is dangerous and many studies especially about radon have been done in this area. For these reasons and becauses some areas of Ramsar, a city in northern Iran in mazandaran province, have been among the highest known background radiation levels in the world we measured radon and radium concentrations in water sources of Ramsar region. In this study, Radon and radium concentrations of the 22 streams and 20 drinking water samples were measured by PRASSI system. According to the data, the arithmetic mean of radon concentration for all samples was 3.030 ± 1.122 Bq/l. Similarly, arithmetic mean of radium for all samples was 0.185 ± 0.055 Bq/l. Also 1 sample of streams and 1 sample of drinking water showed radon concentration higher than 10Bq/l as normal level. Radium-226 alone, in 11 samples of streams and 8 samples of drinking water had concentrations higher than 0.185Bq/l as normal level for the combined Radium-226 and Radium-228.

  11. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  12. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  13. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  14. The use of mechanical ventilation with heat recovery for controlling radon and radondaughter concentrations in houses

    Science.gov (United States)

    Nazaroff, W. W.; Boegel, M. L.; Hollowell, C. D.; Roseme, G. D.

    An energy research house in Maryland was found to have radon concentrations far in excess of recommended guidelines. A mechanical ventilation system with heat recovery was installed in this house to test its effectiveness as an energy-efficient control technique for indoor radon. Radon concentration was monitored continuously for 2 weeks under varying ventilation conditions [0.07-0.8 air changes per hour (ach)] and radondaughter concentrations were measured by grab-sample techniques about nine times daily during this period. At ventilation rates of 0.6 ach and higher, radon-daughter levels dropped below guidelines for indoor concentrations. Comparison with other studies indicates that indoor radon buildup may be a problem in a considerable portion of houses characterized by their low infiltration rates. The use of mechanical ventilation systems with air-to-air heat exchangers may offer a practical, cost-effective and energy-efficient means of alleviating not only the radon problem specifically but also the general deterioration of indoor air quality in many houses designed or retrofitted to achieve low infiltration.

  15. A European-wide 222radon and 222radon progeny comparison study

    Science.gov (United States)

    Schmithüsen, Dominik; Chambers, Scott; Fischer, Bernd; Gilge, Stefan; Hatakka, Juha; Kazan, Victor; Neubert, Rolf; Paatero, Jussi; Ramonet, Michel; Schlosser, Clemens; Schmid, Sabine; Vermeulen, Alex; Levin, Ingeborg

    2017-04-01

    Although atmospheric 222radon (222Rn) activity concentration measurements are currently performed worldwide, they are being made by many different laboratories and with fundamentally different measurement principles, so compatibility issues can limit their utility for regional-to-global applications. Consequently, we conducted a European-wide 222Rn / 222Rn progeny comparison study in order to evaluate the different measurement systems in use, determine potential systematic biases between them, and estimate correction factors that could be applied to harmonize data for their use as a tracer in atmospheric applications. Two compact portable Heidelberg radon monitors (HRM) were moved around to run for at least 1 month at each of the nine European measurement stations included in this comparison. Linear regressions between parallel data sets were calculated, yielding correction factors relative to the HRM ranging from 0.68 to 1.45. A calibration bias between ANSTO (Australian Nuclear Science and Technology Organisation) two-filter radon monitors and the HRM of ANSTO / HRM = 1.11 ± 0.05 was found. Moreover, for the continental stations using one-filter systems that derive atmospheric 222Rn activity concentrations from measured atmospheric progeny activity concentrations, preliminary 214Po / 222Rn disequilibrium values were also estimated. Mean station-specific disequilibrium values between 0.8 at mountain sites (e.g. Schauinsland) and 0.9 at non-mountain sites for sampling heights around 20 to 30 m above ground level were determined. The respective corrections for calibration biases and disequilibrium derived in this study need to be applied to obtain a compatible European atmospheric 222Rn data set for use in quantitative applications, such as regional model intercomparison and validation or trace gas flux estimates with the radon tracer method.

  16. Soil radon measurements as potential tracer of seismic and volcanic activity at Etna

    Science.gov (United States)

    Neri, Marco; Giammanco, Salvatore; Galli, Gianfranco; Ferrera, Elisabetta

    2014-05-01

    Radon is a radioactive noble gas present in all rocks of the Earth. It's used by the scientific community as a tracer of natural phenomena related to outgassing from the soil along faults, fractures and crustal discontinuity. Recently, radon has also been used on active volcanoes such as Etna, both as a precursor of volcanic phenomena as well as in the study of the dynamics of faults. The Istituto Nazionale di Geofisica e Vulcanologia (INGV) performs discrete and continuous measurements of radon from soil at Etna since 2002. First studies concerned measurements of radon and thoron emissions from soil carried out on the E and SW flanks of Etna, in zones characterized by the presence of numerous seismogenic and aseismic faults. The statistical treatment of the geochemical data allowed recognizing anomaly thresholds, producing distribution maps that highlighted a significant spatial correlation between soil gas anomalies and tectonic lineaments. These studies confirmed that mapping the distribution of radon and thoron in soil gas can reveal hidden faults buried by recent soil cover. INGV permanent radon monitoring network was installed in July 2005. First results were obtained during the July 2006 eruption. The radon signal recorded at Torre del Filosofo (TdF, ~2950 m asl) was compared with volcanic tremor and thermal radiance data. The onset of explosive activity and a lava fountaining episode were preceded by some hours with increases in radon activity and more gradual increases in volcanic tremor. After 2006, Etna produced dozens of paroxysmal episodes from a new vent opened on the eastern flank of the Southeast Crater (summit area), that have built up a new, huge pyroclastic cone. In many cases we observed increase in radon activity some hours before the eruptive events. These observations suggest that radon emissions from the TdF zone are sensitive to the local geodynamic pressure induced by magma dynamics in the conduit systems. Other promising results were

  17. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  18. Milliwave melter monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, William E [North Augusta, SC; Woskov, Paul P [Bedford, MA; Sundaram, Shanmugavelayutham K [Richland, WA

    2011-08-16

    A milliwave melter monitoring system is presented that has a waveguide with a portion capable of contacting a molten material in a melter for use in measuring one or more properties of the molten material in a furnace under extreme environments. A receiver is configured for use in obtaining signals from the melt/material transmitted to appropriate electronics through the waveguide. The receiver is configured for receiving signals from the waveguide when contacting the molten material for use in determining the viscosity of the molten material. Other embodiments exist in which the temperature, emissivity, viscosity and other properties of the molten material are measured.

  19. Storage monitoring system -- 1997

    Energy Technology Data Exchange (ETDEWEB)

    Mickelsen, B.; Nilsen, C.; Kinzel, R. [Sandia National Labs., Livermore, CA (United States); Davidson, B.; Pollock, R. [Sandia National Labs., Albuquerque, NM (United States)

    1997-11-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them.

  20. Indoor radon survey in dwellings of some regions in Yemen

    Energy Technology Data Exchange (ETDEWEB)

    Khayrat, A.H. E-mail: akhayrat@yahoo.com; Al-Jarallah, M.I.; Fazal-ur-Rehman, X.; Abu-Jarad, F

    2003-06-01

    Indoor radon survey in a total of 241 dwellings, distributed in some regions of Yemen was performed, using CR-39 based radon monitors. The objective of this radon survey is to get representative indoor radon data of three regions, namely Dhamar, Taiz and Hodeidah, situated at different altitudes above sea level. The radon concentrations varied from 3 to 270 Bq m{sup -3} with an average of 42 Bq m{sup -3}. It was found that the average radon concentration in the surveyed areas increases with altitudes. The highest average radon concentration of 59 Bq m{sup -3} was found in Dhamar city while the lowest average concentration of 8 Bq m{sup -3} was found in Hodeidah city.

  1. Inter-comparison of different direct and indirect methods to determine radon flux from soil

    Energy Technology Data Exchange (ETDEWEB)

    Grossi, C., E-mail: claudia.grossi@upc.ed [Institute of Energy (INTE), Technical University of Catalonia (UPC) (Spain); Vargas, A.; Camacho, A. [Institute of Energy (INTE), Technical University of Catalonia (UPC) (Spain); Lopez-Coto, I.; Bolivar, J.P. [University of Huelva (Spain); Xia Yu; Conen, F. [University of Basel (Switzerland)

    2011-01-15

    The physical and chemical characteristics of radon gas make it a good tracer for use in the application of atmospheric transport models. For this purpose the radon source needs to be known on a global scale and this is difficult to achieve by only direct experimental methods. However, indirect methods can provide radon flux maps on larger scales, but their reliability has to be carefully checked. It is the aim of this work to compare radon flux values obtained by direct and indirect methods in a measurement campaign performed in the summer of 2008. Different systems to directly measure radon flux from the soil surface and to measure the related parameters terrestrial {gamma} dose and {sup 226}Ra activity in soil, for indirect estimation of radon flux, were tested. Four eastern Spanish sites with different geological and soil characteristics were selected: Teruel, Los Pedrones, Quintanar de la Orden and Madrid. The study shows the usefulness of both direct and indirect methods for obtaining radon flux data. Direct radon flux measurements by continuous and integrated monitors showed a coefficient of variation between 10% and 23%. At the same time, indirect methods based on correlations between {sup 222}Rn and terrestrial {gamma} dose rate, or {sup 226}Ra activity in soil, provided results similar to the direct measurements, when these proxies were directly measured at the site. Larger discrepancies were found when proxy values were extracted from existing data bases. The participating members involved in the campaign study were the Institute of Energy Technology (INTE) of the Technical University of Catalonia (UPC), Huelva University (UHU), and Basel University (BASEL).

  2. Radon in the soil air of Estonia.

    Science.gov (United States)

    Petersell, Valter; Täht-Kok, Krista; Karimov, Mark; Milvek, Heli; Nirgi, Siim; Raha, Margus; Saarik, Krista

    2017-01-01

    Several investigations in Estonia during 1996¬-1999 have shown that permissible level (200 Bq/m3) of radon (222Rn) in indoor air is exceeded in 33% of the inspected dwellings. This makes Estonia one of the five countries with highest radon risk in Europe (Fig 1). Due to correlation between the soil radon risk level and radon concentration in houses, small scale radon risk mapping of soil air was carried out (one study point per 70-100 km2). It turned out that one-third of Estonian mainland has high radon risk potential, where radon concentration in soil air exceeds safe limit of 50 kBq/m3. In order to estimate radon content in soil air, two different methods developed in Sweden were used simultaneously. Besides measuring radon content from soil air at the depth of 80 cm with an emanometer (RnM), maximum potential content of radon in soil (RnG) was estimated based on the rate of eU (226Ra) concentration in soil, which was acquired by using gamma-ray spectrometer. Mapping and following studies revealed that simultaneously measured RnG and RnM in study points may often differ. To inspect the cause, several monitoring points were set up in places with different geological conditions. It appeared that unlike the RnG content, which remains close to average level in repeated measurements, the RnM content may differ more than three times periodically. After continuous observations it turned out that concentration of directly measured radon depended on various factors being mostly controlled by mineral composition of soil, properties of topsoil as well as different factors influencing aeration of soil. The results of Rn monitoring show that reliable level of radon risk in Estonian soils can only be acquired by using calculated Rn-concentration in soil air based on eU content and directly measured radon content of soil air in combination with interpreting specific geological and geochemical situations in the study points. Copyright © 2016 Elsevier Ltd. All rights

  3. AlphaGUARD, the new reference for continuous radon monitoring in air, soil, gas, water and material; AlphaGUARD, die neue Referenz fuer die kontinuierliche Messung der Radonkonzentration in Luft, Boden, Wasser und Baumaterial

    Energy Technology Data Exchange (ETDEWEB)

    Roessler, F.; Buerkin, W. [Saphymo GmbH, Frankfurt am Main (Germany); Villert, J. [Bertin Technologies, Montigny (France)

    2016-07-01

    The company Saphymo GmbH has more than 25 years of experience in the field of radon measurement. More than 20 years ago Saphymo developed the professional and robust radon monitor AlphaGUARD, quickly recognized as a standard for reliable and continuous measurements of the radon concentration. Today AlphaGUARD is internationally established as the reference in radon measurement. Following up on this success story the new generation of AlphaGUARD can now be presented. Based on the excellent measurement characteristics of its predecessor the new AlphaGUARD combines the well-proven principle of the pulse ionisation chamber with new and additional features. The robust housing is oriented on the well-proven design of the predecessor and includes now an integrated flow controlled and powerful pump. The instrument can be operated in flow as well as in diffusion mode (without pump). Via the new large display and the intuitive menu navigation all measurement data can be retrieved. The presentation of time series in charts is possible as well as the parametrisation of the instrument. A wide range of accessories, developed in cooperation with various radon experts of universities and laboratories, enables the user a varied and flexible application of the AlphaGUARD: Measurement of the radon concentration in air (radon, thoron, radon progenies), in water (sampling and time resolved measurements) and in soil (soil gas measurements, exhalation measurements), emanation measurements from material, multi spot measurement, online measurement with remote data transmission via Ethernet/DSL, Bluetooth, Wi-Fi, GPRS/3G or satellite. Due to its high sensitivity and its fast and linear response over a large measuring range the AlphaGUARD is excellently suited for calibration laboratories. Furthermore the AlphaGUARD enables ideal prerequisites for field applications: robust housing for operations under harsh conditions, long battery life for the measurement at any location, low

  4. Application of the can technique and radon gas analyzer for radon exhalation measurements.

    Science.gov (United States)

    Fazal-ur-Rehman; Al-Jarallah, M I; Musazay, M S; Abu-Jarad, F

    2003-01-01

    A passive "can technique" and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bqm(-2)h(-1) with an average of 1.35+/-1.40 Bqm(-2)h(-1). The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  5. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  6. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  7. Quantifying stability influences on air pollution in Lanzhou, China, using a radon-based "stability monitor": Seasonality and extreme events

    Science.gov (United States)

    Wang, Fenjuan; Chambers, Scott D.; Zhang, Zhenyi; Williams, Alastair G.; Deng, Xiaodong; Zhang, Hua; Lonati, Giovanni; Crawford, Jagoda; Griffiths, Alan D.; Ianniello, Antonietta; Allegrini, Ivo

    2016-11-01

    A recently-developed radon-based technique is modified to quantify the seasonal influences of atmospheric stability on urban emissions in Lanzhou, China, based on 11 months of observations at three sites with contrasting pollution characteristics. Near-surface concentrations of primary (CO, SO2, NOx) and secondary (O3) gas phase pollutants responded to changing atmospheric stability in markedly different ways in winter and summer, primarily because monsoonal fetch changes strongly influenced the distance between measurement sites and their nearest upwind pollutant sources, but also due to mean diurnal changes in mixing depth. Typically, morning peak primary pollution concentrations increased by a factor of 2-5 from the most well-mixed to stable conditions, whereas nocturnal ozone concentrations reduced with increasing stability due to surface loss processes and the progressively reduced coupling between the nocturnal boundary layer and overlying free atmosphere. The majority of pollution exceedance events (cf. China National Air Quality Standard guideline values) occurred in winter, when all measurement stations were downwind of the city's main pollution sources, and were directly attributed to morning periods and stable atmospheric conditions. In the sheltered valley region of Lanzhou, extremes of winter nocturnal stability states represented a change in mean nocturnal wind speed of only 0.25 m s-1 (from 0.6 to 0.85 m s-1). Daily-integrated PM10 concentrations increased by a factor of 2 in winter from the most well-mixed to stable conditions, and were usually above guideline values at the industrial and residential sites for all atmospheric stability conditions. In summer, however, daily mean PM10 exceedances usually only occurred at the industrial site, under stable conditions. Finally, a simple model - based on mean radon concentrations between 1900 and 0400 h - is proposed to predict haze conditions in the city prior to commencement of the peak morning

  8. Report on correlation between radon outgassing and aftershocks activity along the Bam Fault in Kerman province of Iran

    Energy Technology Data Exchange (ETDEWEB)

    Nabipour, Jamshid Soltani [Bio-Nuclear and Medical Radiation Engineering Department, Parand Branch, Islamic Azad University, Parand (Iran, Islamic Republic of); Khorshidi, Abdollah, E-mail: abkhorshidi@yahoo.com [Cellular and Molecular Gerash Research Center, Gerash University of Medical Sciences (Iran, Islamic Republic of)

    2017-09-01

    After the Earthquake in Bam in December 26, 2003, a team was dispatched to this area to monitor the relationship between Variation in the Radon ({sup 222}Rn) concentration and the magnitude of aftershocks. Meteorological parameters such as air pressure, temperature and humidity were measured. Radon concentration at depth of 90 cm of soil was also measured using AlphaGuard (Model 2000PRO) in 10 minutes periods. The measurement site was near the fault location and the radon concentration was systemically measured for a period of three months. A correlation between radon concentration and the available aftershocks data is discussed. More than 150 small to moderate aftershocks with a magnitude ranging from M=2.1 to 6.5 in scale of Richter occurred in the region during the period of this study at the various distances (below 20 km of epicenter) from the radon monitoring sites. When the magnitude of aftershocks increased, variations of radon concentration could be observed more clearly. (author)

  9. Radon in Saudi houses

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Al-Jarallah, M.I.

    1986-01-01

    A total of 637 passive radon dosemeters (CR-39 nuclear track detectors in a closed chamber) were used in a survey in 400 houses in Saudi Arabia. The radon concentration was found to vary from 5 to 36 Bq.m/sup -3/ (0.13 to 0.98 pCi.l/sup -1/) with a mean of 16 Bq.m/sup -3/ (0.43 pCi.l/sup -1/). The unoccupied houses showed a concentration of 29+-7 Bq.m/sup -3/ (0.78+-0.19 pCi.l/sup -1/) double that of the occupied houses, 14+-1 Bq.m/sup -3/ (0.39+-0.02 pCi.l/sup -1/), in the same area. The radon daughter concentration measured with a Working Level monitor in 17 unoccupied houses was found to vary from 1.35x10/sup -3/ to 24x10/sup -3/ WL with an average of 6.9+-1.4x10/sup -3/ WL. The average exhalation rate measured in 37 houses by 95 passive detectors in cans sealed to the walls ranged from 0.013 to 0.044 Bq.m/sup -2/.h/sup -1/(0.35 to 1.2 pCi.m/sup -2/.h/sup -1/) with an average of 0.021+-0.003 Bq.m/sup -2/.h/sup -1/(0.56+-0.09 pCi.m/sup -2/.h/sup -1/). This survey is the first in Saudi Arabia (a hot climate) and can usefully be compared with similar surveys in countries with cold climates.

  10. Radon Guide for Tenants

    Science.gov (United States)

    This guide is for people who rent their apartments or houses. The guide explains what radon is, and how to find out if there is a radon problem in your home. The guide also talks about what you can do if there are high radon levels in your home.

  11. Investigation of radon entry and effectiveness of mitigation measures in seven houses in New Jersey: Midproject report

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, T.G.; Dudney, C.S.; Monar, K.P.; Landguth, D.C.; Wilson, D.L.; Hawthorne, A.R.; Hubbard, L.M.; Gadsby, K.J.; Bohac, D.L.; Decker, C.A.

    1987-12-01

    A detailed radon mitigation study is in progress in 14 homes in the New Jersey Piedmont area. The principal goals are the refinement of diagnostic measurements for selection and implementation of mitigation systems, and the reduction of radon concentrations to acceptable levels inside the study houses. Monitoring stations were installed in each home in October, 1986. Instrumented measurements included: basement and upstairs radon; differential pressures across the basement/subslag, basement/upstairs and basement/outdoor interfaces; temperatures at basement, upstairs and outdoor locations; and central air handler usage. A weather station was located at one house, monitoring wind speed and direction; barometric pressure; precipitation; soil temperature; and outdoor temperature and relative humidity. A time-averaged value of all of the above parameters was recorded every 30 min. Several additional parameters were monitored on an intermittent basis in all or selected homes. These include multizone air infiltration rates which have been measured in all homes using passive perfluorocarbon tracers (PFT) and in two homes using a constant concentration tracer gas system (CCTG). Total radon progeny, soil gas radon concentration and permeability characteristics, and gamma radiation levels were also monitored periodically in all study homes. 10 refs., 53 figs.

  12. Radon Assessment of Occupational Facilities, Homestead ARB, FL

    Science.gov (United States)

    2013-11-21

    Consultative Letter 3. DATES COVERED (From – To) May 2013 – August 2013 4. TITLE AND SUBTITLE Radon Assessment of Occupational Facilities...unlimited. Case Number: 88ABW-2013-4919, 21 Nov 2013 13. SUPPLEMENTARY NOTES 14. ABSTRACT An assessment of indoor radon concentrations was...established in AFI 48-148 for long-term monitoring. Historical results indicate a radon risk characterization category of “medium,” requiring all

  13. Development and calibration of a high sensitive radon detector in air

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Machiko [Tokai Univ., Hiratsuka, Kanagawa (Japan). Faculty of Science; Tasaka, Shigeki; Hori, Hidemitsu; Okumura, Kimihiro; Kajita, Takaaki; Takeuchi, Yasuo; Okazawa, Hiroko

    1998-12-31

    A high sensitive radon detector was developed in order to measure radon concentration for Super-Kamiokande. Super-Kamiokande is a large water Cerenkov detector located 1000 m underground in the Kamioka mine in Gifu Prefecture. It consists of a cylindrical stainless steel tank (39-meter in diameter and 42-meter in height), 50000-ton of purified water, 11146 20-inch PMT, a water and air purification system, electronics systems, and so on. One of the main purposes of Super-Kamiokande is to observe solar neutrinos. The background events in the lower energy region are dominated by beta decay of radon daughters remaining in the water. The radon concentration in the water should be less than about 5 mBq/m{sup 3}. As a first step to monitor the radon concentration in water, a high sensitive detector for radon in air was developed. We adopted the electrostatic collection method and used a PIN photodiode to measure the energy of alpha particles from the daughter nuclei of {sup 222}Rn. To study the high voltage and absolute humidity dependence of the radon detector, a calibration system was also constructed. As a result of the calibration study, the absolute humidity dependence was clearly observed in the region less than 1.6 g/m{sup 3}. The calibration factors were 1.8{+-}0.1 (count/day)/(mBq/m{sup 3}) at 0.08 g/m{sup 3} and 0.75{+-}0.04 (count/day)/(mBq/m{sup 3}) at 11 g/m{sup 3}. As a result, the detection limit at 0.08 g/m{sup 3} is 13 mBq/m{sup 3}/day. (author)

  14. CERN Safety System Monitoring - SSM

    CERN Document Server

    Hakulinen, T; Valentini, F; Gonzalez, J; Salatko-Petryszcze, C

    2011-01-01

    CERN SSM (Safety System Monitoring) [1] is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs, servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix [2], on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from handheld devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems.

  15. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    precautionary measures), should have assured quality of the used measuring systems. In this respect the findings from this intercomparison exercise are used for an actual control, improvement of the calibration and optimization to ensure the correct application of the used radon measuring systems in Austria. (authors)

  16. An automated, semi-continuous system for measuring indoor radon progeny activity-weighted size distributions, d sub p : 0. 5--500 nm

    Energy Technology Data Exchange (ETDEWEB)

    Li, Chih-Shan; Hopke, P.K.; Ramamurthi, M.

    1990-05-01

    A system for the detection and measurement of indoor radon progeny activity-weighted size distributions (particle size, d{sub p} > 0.5 nm) and concentration levels has been developed. The system is microcomputer-controlled and involves a combination of multiple wire screen (Graded Screen Array) sampler-detector units operated in parallel. The radioactivity sampled in these units permits the estimation of the radon progeny activity-weighted size distributions and concentration levels on a semi-continuous basis. This paper presents details of the system and describes various stages in the development of the system. Results of field measurements in a residential environment are presented to illustrate the resolution, sensitivity and capabilities of the measurement system. 16 refs., 4 figs., 1 tab.

  17. Application of nuclear track detectors for radon related measurments

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.A. (King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia). Energy Resources Div.)

    1988-01-01

    The application of nuclear track detectors for radon related measurements is discussed. The ''Can Technique'', used for measuring radon emanation from building materials, walls and soil; the ''Working Level Monitor'', used for measuring short period working levels of radon daughters in houses; and ''Passive Radon Dosimeters'', used to measure radon levels in houses for long term (few months) periods are described. Application of nuclear track detectors for measuring the radon daughters plate-out on the surface of mixing fan blades and walls are discussed. The uranium content of some wall papers was found to be 6 ppm. The variation of radon progeny concentration in the same room was measured and supported by another study through Gas Chromatograph measurements. The independence of radon concentration on room level in high-rise buildings was established. The effect of sub-floor radon emanation on radon concentration in houses is dependent on whether there is sub-floor ventilation or not. (author).

  18. Radon Concentration in the Cataniapo-Autana River Basin, Amazonas State, Venezuela

    Science.gov (United States)

    Sajo-Bohus, L.; Greaves, E. D.; Alvarez, H.; Liendo, J.; Vásquez, G.

    2007-10-01

    Radon activity concentration is measured in rivers of the Autana-Cataniapo hydrologic basin. The region experiments mining and it is forecasted that the basin will be perturbed. Radon activity monitoring is one of the methods to measure environmental changes. Values of radon concentration in water range between 0.4 and 30 Bq L-1.

  19. The transfer of radon from potable water into house air

    Energy Technology Data Exchange (ETDEWEB)

    Hess, C.T.; Vietti, M.A.; Lachapelle, E.B.; Guillemette, J.F. (Univ. of Maine, Orono (USA))

    1988-09-01

    There have been very few comparisons of the radon in air due to use of potable water containing radon. To better determine the health risk due to radon in water in homes, 40 houses in southern and central Maine were measured for house characteristics such as building materials, volume and air exchange rate and for radon in water and air. The houses were all wood with basements and have wood, oil and solar heat. To increase the radon due to water use, a two hour water burst was used to simulate 24 hours of water use for the occupants. The water use was monitored along with the radon concentration in air for ten minute intervals.

  20. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  1. Indoor radon; Le radon dans les batiments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies.

  2. Evaluation of efficiency calibration parameters of the LR-115 radon detector.

    Science.gov (United States)

    Mireles, F; Dávila, J I; García, M L; Pinedo, J L; López, H

    2010-05-01

    Measurement of 222Rn is an important research concern because of the high-energy alpha emission of its 218Po and 214Po progeny. The LR-115 passive detector is the basis of a solid-state nuclear track detector (SSNTD) whose use for radon measurements has been well established. The usage of the SSNTD technique requires calibration by comparison. The aim of this work is to evaluate the efficiency calibration parameters for the radon measurement system that three steps: (1) irradiation conditions, (2) etching conditions, and (3) track counting. The following parameters were evaluated: breakdown and counting voltages for the spark counter, detector thickness, etching time, temperature and NaOH concentration as etching conditions for the LR-115 detector. Calibrating factors of 0.035 and 0.028 tracks cm-2 Bq-1 m3 d-1 for the open- and closed-chamber radon monitors, respectively, were determined considering the best efficiency calibration parameter values.

  3. Optimizing laboratory-based radon flux measurements for sediments.

    Science.gov (United States)

    Chanyotha, Supitcha; Kranrod, Chutima; Kritsananuwat, Rawiwan; Lane-Smith, Derek; Burnett, William C

    2016-07-01

    Radon flux via diffusion from sediments and other materials may be determined in the laboratory by circulating air through the sample and a radon detector in a closed loop. However, this approach is complicated by the necessity of having to determine the total air volume in the system and accounting for any small air leaks that can arise if using extended measurement periods. We designed a simple open-loop configuration that includes a measured mass of wet sediment and water inside a gas-tight reaction flask connected to a drying system and a radon-in-air analyzer. Ambient air flows through two charcoal columns before entering the reaction vessel to eliminate incoming radon. After traveling through the reaction flask, the air passes the drier and the radon analyzer and is then vented. After some time, the radon activity will reach a steady state depending upon the airflow rate. With this approach, the radon flux via diffusion is simply the product of the steady-state radon activity (Bq/m(3)) multiplied by the airflow rate (mL/min). We demonstrated that this setup could produce good results for materials that produce relatively high radon fluxes. We also show that a modified closed system approach, including radon removal of the incoming air by charcoal filtration in a bypass, can produce very good results including samples with very low emission rates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Consumer's Guide to Radon Reduction

    Science.gov (United States)

    ... Protection Agency Search Search Radon Contact Us Share Consumer's Guide to Radon Reduction: How to Fix Your ... See EPA’s About PDF page to learn more. Consumer's Guide to Radon Reduction: How to Fix Your ...

  5. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  6. Radiological risk assessment of environmental radon

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Norafatin; Majid, Amran Ab; Yahaya, Redzuwan; Yasir, Muhammad Samudi [Nuclear Science Programme, School of Applied Physics, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor Darul Ehsan (Malaysia)

    2013-11-27

    Measurements of radon gas ({sup 222}Rn) in the environmental are important to assess indoor air quality and to study the potential risk to human health. Generally known that exposure to radon is considered the second leading cause of lung cancer after smoking. The environmental radon concentration depends on the {sup 226}Ra concentration, indoor atmosphere, cracking on rocks and building materials. This study was carried out to determine the indoor radon concentration from selected samples of tin tailings (amang) and building materials in an airtight sealed homemade radon chamber. The radiological risk assessment for radon gas was also calculated based on the annual exposure dose, effective dose equivalent, radon exhalation rates and fatal cancer risk. The continuous radon monitor Sun Nuclear model 1029 was used to measure the radon concentration emanates from selected samples for 96 hours. Five types of tin tailings collected from Kampar, Perak and four samples of building materials commonly used in Malaysia dwellings or building constructions were analysed for radon concentration. The indoor radon concentration determined in ilmenite, monazite, struverite, xenotime and zircon samples varies from 219.6 ± 76.8 Bq m{sup −3} to 571.1 ± 251.4 Bq m{sup −3}, 101.0 ± 41.0 Bq m{sup −3} to 245.3 ± 100.2 Bq m{sup −3}, 53.1 ± 7.5 Bq m{sup −3} to 181.8 ± 9.7 Bq m{sup −3}, 256.1 ± 59.3 Bq m{sup −3} to 652.2 ± 222.2 Bq m{sup −3} and 164.5 ± 75.9 Bq m{sup −3} to 653.3 ± 240.0 Bq m{sup −3}, respectively. Whereas, in the building materials, the radon concentration from cement brick, red-clay brick, gravel aggregate and cement showed 396.3 ± 194.3 Bq m{sup −3}, 192.1 ± 75.4 Bq m{sup −3}, 176.1 ± 85.9 Bq m{sup −3} and 28.4 ± 5.7 Bq m{sup −3}, respectively. The radon concentration in tin tailings and building materials were found to be much higher in xenotime and cement brick samples than others. All samples in tin tailings were exceeded the

  7. An indoor radon survey of the X-ray rooms of Mexico City hospitals

    Energy Technology Data Exchange (ETDEWEB)

    Juarez, Faustino [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario No. 100. Estado de Mexico, 50000, Mexico. Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Circuito (Mexico); Reyes, Pedro G. [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario No. 100. Estado de Mexico, 50000 (Mexico); Espinosa, Guillermo [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito Exterior Ciudad Universitaria, Mexico D.F. Cp.04510 (Mexico)

    2013-07-03

    This paper presents the results of measurements of indoor radon concentrations in the X-ray rooms of a selection of hospitals in the metropolitan area of Mexico City. The metropolitan area of Mexico City is Mexico's largest metropolitan area by population; the number of patients requiring the use of X-rays is also the highest. An understanding of indoor radon concentrations in X-ray rooms is necessary for the estimation of the radiological risk to which patients, radiologists and medical technicians are exposed. The indoor radon concentrations were monitored for a period of six months using nuclear track detectors (NTD) consisting of a closed-end cup system with CR-39 (Lantrack Registered-Sign ) polycarbonate as detector material. The indoor radon concentrations were found to be between 75 and 170 Bq m{sup -3}, below the USEPA-recommended indoor radon action level for working places of 400 Bq m{sup -3}. It is hoped that the results of this study will contribute to the establishment of recommended action levels by the Mexican regulatory authorities responsible for nuclear safety.

  8. Engineering monitoring expert system's developer

    Science.gov (United States)

    Lo, Ching F.

    1991-01-01

    This research project is designed to apply artificial intelligence technology including expert systems, dynamic interface of neural networks, and hypertext to construct an expert system developer. The developer environment is specifically suited to building expert systems which monitor the performance of ground support equipment for propulsion systems and testing facilities. The expert system developer, through the use of a graphics interface and a rule network, will be transparent to the user during rule constructing and data scanning of the knowledge base. The project will result in a software system that allows its user to build specific monitoring type expert systems which monitor various equipments used for propulsion systems or ground testing facilities and accrues system performance information in a dynamic knowledge base.

  9. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  10. Occupational doses from radon in Spanish spas.

    Science.gov (United States)

    Soto, J; Gómez, J

    1999-04-01

    Recent international recommendations have included exposure to natural radiation as one of the sources to monitor in certain occupationally exposed groups. Among those mentioned are workers in thermal spas, who may be exposed to high radiation doses due to the high concentration of radon in the indoor air of the spa. This paper presents the methodology and the results of an evaluation of radiation doses to the staff in different thermal spas in Spain. Different series of samples were collected and measurements made for the radon concentrations in water in 54 spas and in air in 20 spas. In six of the latter group, the air radon concentration was studied in different working areas occupied by the employees. The radon concentrations in water were between radon concentrations in air were between radon concentration in their main working area. By means of an exposure-dose conversion factor of 1.43 Sv per J h m(-3), the estimated effective doses were found to lie between 1 and 44 mSv y(-1). This upper limit is higher than the recommended annual limit of 20 mSv y(-1) for an occupational dose.

  11. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  12. Radon Optical Processing in Radon Space.

    Science.gov (United States)

    1986-06-15

    and have been considered at length elsewhere (Rowland, 1979) (3arrett and Swindell , 1981) . Rather, we wish to investigate the use of the Radon... Swindell :1977, 1981) or Larrett (1984). We can also express the inverse Radon transform in operator notation (Barrett, 1984), expanding the operator PR...similar signal processing capability over a wide range of input frequencies ( Roberts , 1977). fe Linear FM, or chirp, SAW filters are easily made and have

  13. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  14. YAPILARDA RADON FENOMENY

    OpenAIRE

    OZAN, Sadik Sezgin; EKİNCİ, Cevdet Emin

    2011-01-01

    Bu çaly?mada, yapylarda Radon konusu irdelenmi?tir. Radon, günlük hayatta sürekli maruz kaldy?ymyz radyasyonun yakla?yk %50'sini olu?turan ve topraktaki Uranyum'un bozunma zincirinin bir halkasy olan renksiz, kokusuz ve duyu organlaryyla algylanamayan radyoaktif bir gazdyr. Kayaçlardaki Uranyumun bozunmasy sonucu ortaya çykan Radon gazy, difüzyon yoluyla topra?a, oradan da atmosfere veya ortama yayylmaktadyr. Gazyn birikmesiyle, Radon yo?unlu?u kapaly mekânlarda veya iyi havalandyrylmayan yer...

  15. YAPILARDA RADON FENOMENY

    OpenAIRE

    OZAN, Sadik Sezgin; EKİNCİ, Cevdet Emin

    2011-01-01

    Bu çaly?mada, yapylarda Radon konusu irdelenmi?tir. Radon, günlük hayatta sürekli maruz kaldy?ymyz radyasyonun yakla?yk %50'sini olu?turan ve topraktaki Uranyum'un bozunma zincirinin bir halkasy olan renksiz, kokusuz ve duyu organlaryyla algylanamayan radyoaktif bir gazdyr. Kayaçlardaki Uranyumun bozunmasy sonucu ortaya çykan Radon gazy, difüzyon yoluyla topra?a, oradan da atmosfere veya ortama yayylmaktadyr. Gazyn birikmesiyle, Radon yo?unlu?u kapaly mekânlarda veya iyi havalandyry...

  16. Wearable Health Monitoring Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  17. Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon

    Energy Technology Data Exchange (ETDEWEB)

    Chavez B, A.; Balcazar G, M

    1991-10-15

    To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic exchanger system of passive detectors of radon. The results of the new automatic exchanger system when it leave to flow the radon freely among the container and the automatic exchanger through a plastic membrane of 15 m. are shown. (Author)

  18. Bewegingsvolgsysteem = Monitor tracking system

    NARCIS (Netherlands)

    Slycke, P.; Veltink, Petrus H.; Roetenberg, D.

    2006-01-01

    A motion tracking system for tracking an object composed of object parts in a three-dimensional space. The system comprises a number of magnetic field transmitters; a number of field receivers for receiving the magnetic fields of the field transmitters; a number of inertial measurement units for

  19. Radon as geological tracer

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, T.; Anjos, R.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Fisica; Valladares, D.L.; Rizzotto, M.; Velasco, H.; Ayub, J. Juri [Universidad Nacional de San Luis (Argentina). Inst. de Matematica Aplicada San Luis (IMASL); Silva, A.A.R. da; Yoshimura, E.M. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica

    2012-07-01

    Full text: This work presents measurements of {sup 222}Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of {sup 40}K, {sup 232}Th and {sup 23}'8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using {sup 222}Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m{sup -3} recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  20. Risk Monitoring for Space Systems

    Science.gov (United States)

    Kafka, Peter

    2005-12-01

    The paper shows the idea, the drivers and some basics within the wide spread field of Risk Monitoring Systems (RMS) for nuclear power plants. Pros and cons are summarised and the status of last developments is touched. Based on these insights the adoption of RMS for space systems and installations is discussed with the aim to contribute to the advancement of space systems safety.

  1. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  2. Domestic Radon and Childhood Cancer in Denmark

    DEFF Research Database (Denmark)

    Raaschou-Nielsen, Ole; Andersen, Claus Erik; Andersen, Helle P.

    2008-01-01

    Background: Higher incidence rates of childhood cancer and particularly leukemia have been observed in regions with higher radon levels, but case-control studies have given inconsistent results. We tested the hypothesis that domestic radon exposure increases the risk for childhood cancer. Methods......: We identified 2400 incident cases of leukemia, central nervous system tumor, and malignant lymphoma diagnosed in children between 1968 and 1994 in the Danish Cancer Registry. Control children (n = 6697) were selected from the Danish Central Population Registry. Radon levels in residences of children...... and the cumulated exposure of each child were calculated as the product of exposure level and time, for each address occupied during childhood. Results: Cumulative radon exposure was associated with risk for acute lymphoblastic leukemia (ALL), with rate ratios of 1.21 (95% confidence interval = 0...

  3. Healthy Sport Monitoring System

    OpenAIRE

    ABBASOV, Parviz

    2014-01-01

    Every individual responses differently to physical activity. Working out more than body endures can cause serious health problems. Rapid developments in information and communication technologies affects the whole area of health. Recently developed wearable wireless non-invasive health sensors allow us to create healthcare application. This research aims to give an idea for implementation of healthcare systems in sports area. This system will improve healthy and social life and encourage peop...

  4. A grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin; /Fermilab; Nowack, Andreas; /Aachen, Tech. Hochsch.; Padhi, Sanjay; /UC, San Diego; Sarkar, Subir; /INFN, Pisa /Pisa, Scuola Normale Superiore

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  5. Assessment of radon equilibrium factor from distribution parameters of simultaneous radon and radon progeny measurements.

    Science.gov (United States)

    Chen, Jing; Marro, Leonora

    2011-11-01

    In Canada, a radon and radon progeny survey was carried out in the 1970s in 19 cities. To the authors' knowledge, this is the only large survey of simultaneous radon and radon progeny measurements up to the present time. However, the survey was carried out for the purpose of establishing geographic variation of radon and radon progeny; therefore, radon equilibrium factors, F, were not assessed at that time. From the summary results of this large simultaneous radon and radon progeny survey, the characteristics of radon equilibrium factor were assessed. The average F factor assessed from this survey in 12,576 houses is 0.54. The current assessment may indicate that the typical F value of 0.4 recommended by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), and the International Commission on Radiological Protection (ICRP) could lead to a downward bias in the estimation of radon doses to the lung.

  6. On the interaction between radon progeny and particles generated by electronic and traditional cigarettes

    Science.gov (United States)

    Vargas Trassierra, C.; Cardellini, F.; Buonanno, G.; De Felice, P.

    2015-04-01

    During their entire lives, people are exposed to the pollutants present in indoor air. Recently, Electronic Nicotine Delivery Systems, mainly known as electronic cigarettes, have been widely commercialized: they deliver particles into the lungs of the users but a "second-hand smoke" has yet to be associated to this indoor source. On the other hand, the naturally-occurring radioactive gas, i.e. radon, represents a significant risk for lung cancer, and the cumulative action of these two agents could be worse than the agents separately would. In order to deepen the interaction between radon progeny and second-hand aerosol from different types of cigarettes, a designed experimental study was carried out by generating aerosol from e-cigarette vaping as well as from second-hand traditional smoke inside a walk-in radon chamber at the National Institute of Ionizing Radiation Metrology (INMRI) of Italy. In this chamber, the radon present in air comes naturally from the floor and ambient conditions are controlled. To characterize the sidestream smoke emitted by cigarettes, condensation particle counters and scanning mobility particle sizer were used. Radon concentration in the air was measured through an Alphaguard ionization chamber, whereas the measurement of radon decay product in the air was performed with the Tracelab BWLM Plus-2S Radon daughter Monitor. It was found an increase of the Potential Alpha-Energy Concentration (PAEC) due to the radon decay products attached to aerosol for higher particle number concentrations. This varied from 7.47 ± 0.34 MeV L-1 to 12.6 ± 0.26 MeV L-1 (69%) for the e-cigarette. In the case of traditional cigarette and at the same radon concentration, the increase was from 14.1 ± 0.43 MeV L-1 to 18.6 ± 0.19 MeV L-1 (31%). The equilibrium factor increases, varying from 23.4% ± 1.11% to 29.5% ± 0.26% and from 30.9% ± 1.0% to 38.1 ± 0.88 for the e-cigarette and traditional cigarette, respectively. These growths still continue for long

  7. ELECTRONIC FILE MONITORING SYSTEM

    African Journals Online (AJOL)

    GBUBEMI

    2014-11-06

    Nov 6, 2014 ... integrated seamlessly in a global electronic business environment that includes centralized storage of all documents and related content, with the flexibility to distribute any document in the system electronically or to print, fax, or mail it as a hard copy. Things to be considered for this upgrade are Document ...

  8. Health Risk of Radon

    Science.gov (United States)

    ... encouraged by WHO’s attention to this important public health issue. "Radon poses an easily reducible health risk to ... and Toxics Environmental Information by Location Greener Living Health Land, Waste, and Cleanup Lead Mold Pesticides Radon Science Water A-Z Index Laws & ...

  9. MODEL RADIOACTIVE RADON DECAY

    Directory of Open Access Journals (Sweden)

    R.I. Parovik

    2012-06-01

    Full Text Available In a model of radioactive decay of radon in the sample (222Rn. The model assumes that the probability of the decay of radon and its half-life depends on the fractal properties of the geological environment. The dependencies of the decay parameters of the fractal dimension of the medium.

  10. Radon: Not so Noble

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 7. Radon: Not so Noble-Radon in the Environment and Associated Health Problems. Deepanjan Majumdar. General Article Volume 5 Issue 7 July 2000 pp 44-55. Fulltext. Click here to view fulltext PDF. Permanent link:

  11. Radon: Not so Noble

    Indian Academy of Sciences (India)

    electronic configuration. [ 5S25p65d106s26p6]. Deepanjan Majumdar. Radon is a radioactive noble gas that occurs naturally but becomes an environmental hazard when it remains con- centrated in enclosed places .... public water supplies. Rivers carry .... relationship between cancer incidence and radon exposure has.

  12. UAV Delivery Monitoring System

    Directory of Open Access Journals (Sweden)

    San Khin Thida

    2018-01-01

    Full Text Available UAV-based delivery systems are increasingly being used in the logistics field, particularly to achieve faster last-mile delivery. This study develops a UAV delivery system that manages delivery order assignments, autonomous flight operation, real time control for UAV flights, and delivery status tracking. To manage the delivery item assignments, we apply the concurrent scheduler approach with a genetic algorithm. The present paper describes real time flight data based on a micro air vehicle communication protocol (MAVLink. It also presents the detailed hardware components used for the field tests. Finally, we provide UAV component analysis to choose the suitable components for delivery in terms of battery capacity, flight time, payload weight and motor thrust ratio.

  13. Drought forecasting monitoring system

    Science.gov (United States)

    Mendicino, G.; Senatore, A.; Versace, P.

    2003-04-01

    The main characteristics of an integrated system aimed to predict space-time variations of water deficit occurring in southern Italy are described in this note. The system, running since the year 2000, has been developed within the European INTERREG IIC Programme. It is based on an embedded coupling of GIS and models connected with a Data Acquisition System aimed at storing real time data recorded by the Regional tele-metering hydro-meteorological network (Centro Funzionale Meteo Idrologico della Regione Calabria). This network has been strengthened with a great number of stations, most of which are aimed at measuring specific quantities (rainfall, water level, groundwater level, temperature, solar radiation, evaporation, wind speed and direction, soil moisture and soil water matric potential) to be directly used for the estimate of water balance on the southern Italy regions. Geographic information are stored within a GIS according to raster and vector data structures; spatially distributed hydrological quantities are elaborated, managed and stored using a raster data structure, characterised by a 250 m square grid spatial resolution equal to that utilised for the southern Italy Digital Terrain Model. Hydrological coverages are directly obtained by linking GIS with hydrological databases. Specifically, hydro-meteorological information is managed considering two different data types. The first is based on daily hydro-meteorological values recorded by all gauge stations (historic DB) starting from 1925. The latter is based on real time data recorded by tele-metering stations with a 20-minute time step (real time DB). The interaction with databases has been improved realising some Windows-based software applications capable of guaranteeing a more simple and flexible data query, and allowing the user to extract synthetic graphs and reports. These user-DB interfaces can work both autonomously and directly inside the GIS by simple graphical selections on the gauge

  14. Low-background gamma-ray spectrometry for the international monitoring system.

    Science.gov (United States)

    Greenwood, L R; Cantaloub, M G; Burnett, J L; Myers, A W; Overman, C T; Forrester, J B; Glasgow, B G; Miley, H S

    2017-08-01

    PNNL has developed two low-background gamma-ray spectrometers in a new shallow underground laboratory, thereby significantly improving its ability to detect low levels of gamma-ray emitting fission or activation products in airborne particulate in samples from the IMS (International Monitoring System). The combination of cosmic veto panels, dry nitrogen gas to reduce radon and low background shielding results in a reduction of the background count rate by about a factor of 100 compared to detectors operating above ground at our laboratory. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Residential Radon Exposure and Risk of Lung Cancer in Missouri

    Science.gov (United States)

    A case-control study of lung cancer and residential radon exposure in which investigators carried out both standard year-long air measurements and CR-39 alpha detector measurements (call surface monitors)

  16. Development of high sensitivity radon detectors

    CERN Document Server

    Takeuchi, Y; Kajita, T; Tasaka, S; Hori, H; Nemoto, M; Okazawa, H

    1999-01-01

    High sensitivity detectors for radon in air and in water have been developed. We use electrostatic collection and a PIN photodiode for these detectors. Calibration systems have been also constructed to obtain collection factors. As a result of the calibration study, the absolute humidity dependence of the radon detector for air is clearly observed in the region less than about 1.6 g/m sup 3. The calibration factors of the radon detector for air are 2.2+-0.2 (counts/day)/(mBq/m sup 3) at 0.08 g/m sup 3 and 0.86+-0.06 (counts/day)/(mBq/m sup 3) at 11 g/m sup 3. The calibration factor of the radon detector for water is 3.6+-0.5 (counts/day)/(mBq/m sup 3). The background level of the radon detector for air is 2.4+-1.3 counts/day. As a result, one standard deviation excess of the signal above the background of the radon detector for air should be possible for 1.4 mBq/m sup 3 in a one-day measurement at 0.08 g/m sup 3.

  17. Radon capture with silver exchanged zeolites

    Energy Technology Data Exchange (ETDEWEB)

    Hedstroem, H. [Chalmers Univ. of Technology, Goeteborg (Sweden). Nuclear Chemistry; Foreman, M.; Ekberg, C. [Chalmers Univ. of Technology, Goeteborg (Sweden). Nuclear Chemistry; Chalmers Univ. of Technology, Goeteborg (Sweden). Industrial Materials Recycling; Ramebaeck, H. [Chalmers Univ. of Technology, Goeteborg (Sweden). Nuclear Chemistry; Chalmers Univ. of Technology, Goeteborg (Sweden). Industrial Materials Recycling; Swedish Defence Research Agency (FOI), Division of CBRN Defence and Security, Umeaa (Sweden)

    2012-07-01

    To enable laboratory work with larger amounts of {sup 226}Ra and its decay products, e.g., {sup 222}Rn and its daughters, these need to be captured in order to avoid unnecessary alpha contamination of the laboratory work space and ventilation systems. In this study, radon gas was pumped through a column filled with the silver exchanged zeolite called 'silver exchanged molecular sieves 13X' (Ag{sub 84}Na{sub 2}[(AlO{sub 2}){sub 86}(SiO{sub 2}){sub 106}].xH{sub 2}O). After exposure to radon, the radioactivity of the zeolite was measured repeatedly using high resolution gamma spectrometry. It was shown that radon was captured and retained in the silver exchanged zeolite. The zeolites' ability to retain radon was decreased by formation of metallic silver, caused by ionizing radiation. However, the zeolite was regenerated by heating and its radon capture ability was restored. The daughters of radon are not in gas phase and will hence stay on the column. (orig.)

  18. Radon-222 signatures of natural ventilation regimes in an underground quarry.

    Science.gov (United States)

    Perrier, Frédéric; Richon, Patrick; Crouzeix, Catherine; Morat, Pierre; Le Mouël, Jean Louis

    2004-01-01

    Radon-222 activity concentration has been monitored since 1999 in an underground limestone quarry located in Vincennes, near Paris, France. It is homogeneous in summer, with an average value of 1700 Bq m(-3), and varies from 730 to 1450 Bq m(-3) in winter, indicating natural ventilation with a rate ranging from 0.5 to 2.4 x 10(-6) s(-1) (0.04-0.22 day(-1)). This hypothesis is supported by measurements in the vertical access pit where, in winter, a turbulent air current produces a stable radon profile, smoothly decreasing from 700 Bq m(-3) at 20 m depth to 300 Bq m(-3) at surface. In summer, a thermal stratification is maintained in the pit, but the radon-222 concentration jumps repeatedly between 100 and 2000 Bq m(-3). These jumps are due to atmospheric pressure pumping, which induces ventilation in the quarry at a rate of about 0.1 x 10(-6) s(-1) (0.009 day(-1)). Radon-222 monitoring thus provides a dynamical characterisation of ventilation regimes, which is important for the assessment of the long-term evolution of underground systems.

  19. The use of radon as tracer in environmental sciences

    Science.gov (United States)

    Quindos Poncela, Luis; Sainz Fernandez, Carlos; Fuente Merino, Ismael; Gutierrez Villanueva, Jose; Gonzalez Diez, Alberto

    2013-08-01

    Radon can be used as a naturally occurring tracer for environmental processes. By means of grab-sampling or continuous monitoring of radon concentration, it is possible to assess several types of dynamic phenomena in air and water. We present a review of the use of radon and its progeny at the University of Cantabria. Radon can be an atmospheric dynamics indicator related with air mass interchange near land-sea discontinuities as well as for the study of vertical variations of air parameters (average values of different types of stability: 131-580 Bq m-3). Concerning indoor gas, we present some results obtained at Altamira Cave (Spain): from 222 to 6549 Bq m-3 (Hall) and from 999 to 6697 Bq m-3 (Paintings Room). Finally, variations of radon concentration in soil (0.3 to 9.1 kBq m-3) and underground water (values up to 500 Bq l-1) provide relevant information about different geophysical phenomena.

  20. Radon soil-gas concentration and exhalation from mine tailings dams in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Ongori, J.; Lindsay, R. [University of the Western Cape, Department of Physics, Private Bag X17, Bellville 7535 (South Africa); Newman, R. [Stellenbosch University, Department of Physics, Private Bag X1 Matieland 7602 (South Africa); Maleka, P. [iThemba LABS, Department of Nuclear Physics, P. O. Box 722, Somerset West 7129 (South Africa)

    2014-07-01

    In Africa as well as in the world, South Africa plays an important role in the mining industry which dates back almost 120 years. Mining activities in South Africa mainly take place in Gauteng Province. Every year million of tons of rocks are taken from underground, milled and processed to extract gold. The uranium bearing tailings are disposed in dumpsites. These tailings dumps contain considerable amounts of radium ({sup 226}Ra) and have therefore been identified as large sources of radon ({sup 222}Rn). Radon is a noble gas formed by the decay of radium which in turn is derived from the radioactive decay of uranium ({sup 238}U). Radon release from these tailings dumps pose health concerns for the surrounding communities. Radon soil gas concentrations and exhalations from a non-operational mine dump (Kloof) which belongs to Carletonville Gold Field, Witwatersrand, South Africa have been investigated. The continuous radon monitor, the Durridge RAD7 was used to measure {sup 222}Rn soil gas concentration in the tailings dump at five different spots. The radon soil gas concentration levels were measured at depths starting from 30 cm below ground/air interface up to 110 cm at intervals of 20 cm. The concentrations recorded ranged from 26±1 to 472±23 kBq.m{sup -3}. Furthermore, thirty four soil samples were taken from the spots where radon soil gas measurements were measured for laboratory-based measurement using the low background Hyper Pure Germanium (HPGe) gamma-ray detector available at the Environmental Radioactivity Laboratory (ERL), iThemba LABS, Western Cape Province. The soil samples were collected in the depth range 0-30 cm. After analysis the weighted average activity concentrations in the soils samples were 308±7 Bq.kg{sup -1}, 255±5 Bq.kg{sup -1} and 18±1 Bq.kg{sup -1} for {sup 238}U, {sup 40}K and {sup 232}Th, respectively. A number of factors such as the radium activity concentration and its distribution in soil grains, soil grain size, soil porosity

  1. Determination of radon flux rates in a uranium mine, Cluff Lake, Saskatchewan. Report No. INFO-0347

    Energy Technology Data Exchange (ETDEWEB)

    1989-01-01

    In 1986, the Atomic Energy Control Board completed a project in which a computer model (VENTRAD) was developed to model underground mine ventilation systems. The accuracy of the radon/radon daughter concentration predictions by the computer model depend on the input parameters describing the radon source term. At present, there is a lack of reliable data on radon sources in general and in uranium mines in particular. This study determined the flux of radon emitted per unit surface area in selected locations of Amok Ltd.'s underground Cluff Lake uranium mine; measured parameters that can have an influence on radon flux; tested the VENTRAD computer program using the input parameters measured in the mine; and determined the total flux of radon per unit surface area from the total amount of radon exhausted from the mine and the total surface area of the mine openings.

  2. Phonocardiograph system monitors heart sounds

    Science.gov (United States)

    1966-01-01

    Phonocardiograph system monitors the mechanical activity of the heart in extreme environments. It uses a piezoelectric-crystal microphone with an integral preamplifier, and a signal conditioner having special frequency characteristics. The output signals can be recorded on tape, presented aurally, or transmitted telemetrically to a remote station.

  3. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  4. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  5. [Patients' exposure to electromagnetic fields and radon in radon spas].

    Science.gov (United States)

    Politański, Piotr; Olszewski, Jerzy; Mamrot, Paweł; Mariańska, Mlagda; Zmyślony, Marek

    2014-01-01

    Many patients of physiotherapeutic facilities using therapeutic radon are also referred to other treatments involving the use of electromagnetic field (EMF). However, in the light of the theory of EMF influence on free radicals, it is still an open question whether, application of EMF shortly after the radon treatment may alter the biological effects of radon or EMF. The aim of the study was to determine how large is the group of patients exposed to radon and EMF in Poland, and how high is the exposure of these patients to analyzed factors. The results of the study are to be used in the future assessment of the combined effects of radon and EMF in radon spas. Based on the statistical data and interviews held in the major Polish radon spas, the analysis of treatment structure was performed and exposure to radon and EMF was assessed by measuring radon concentrations and characteristic values of exposure to EMF. More than 8000 people per year are subjected to combined exposure to radon and EMF. Significant differences were found between measured radon concentrations (they ranged from approximately 61 kBq/m3 for inhalations with inhaler to only 290 Bq/m3 for graduation towers, p = 0.049) and EMF intensities corresponded to those observed in hazardous and dangerous zones for occupational exposure. The results of the study showed significant differences between radon concentrations during various radon treatments. There is a need to develop clear and universal procedures for the application of radon or radon combined with EMF in radon spas. The effects of patients' exposure to radon, especially combined with EMF need to be further studied.

  6. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  7. Radon i danske lejeboliger

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Skytte Clausen, Louise

    I denne undersøgelse kortlægges radonindholdet i indeluften og det undersøges, hvordan indholdet af radon i indeluften er fordelt og spredes i en ejendom, og om det er muligt at pege på en bygningsdel eller en bygningskomponent som en spredningsvej for radon i boliger. Boligerne er lejeboliger og...... ligger i etageejendomme, kæde- og rækkehuse tilhørende bygningstyper opført fra 1850 og frem. De udvalgte ejendomme ligger i områder af landet, hvor der ved tidligere undersøgelser har vist sig at være en stor andel af huse med et højt indhold af radon i indeluften. Koncentrationen af radon er målt over...

  8. Radon in Schools

    Science.gov (United States)

    ... that the problem can be solved. EPA's national survey of schools produced some alarming results about concentrations in our children's classrooms. Public awareness must be raised about the hazards of radon ...

  9. ROE Radon Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — The polygon dataset represents predicted indoor radon screening levels in counties across the United States. These data were provided by EPA’s Office of Radiation...

  10. 29 CFR 1954.2 - Monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Monitoring system. 1954.2 Section 1954.2 Labor Regulations...) PROCEDURES FOR THE EVALUATION AND MONITORING OF APPROVED STATE PLANS General § 1954.2 Monitoring system. (a... Act, the Assistant Secretary has established a State Program Performance Monitoring System. Evaluation...

  11. Slow Monitoring Systems for CUORE

    Science.gov (United States)

    Dutta, Suryabrata; Cuore Collaboration

    2016-09-01

    The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale neutrinoless double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS). The experiment is comprised of 988 TeO2 bolometric crystals arranged into 19 towers and operated at a temperature of 10 mK. We have developed slow monitoring systems to monitor the cryostat during detector installation, commissioning, data taking, and other crucial phases of the experiment. Our systems use responsive LabVIEW virtual instruments and video streams of the cryostat. We built a website using the Angular, Bootstrap, and MongoDB frameworks to display this data in real-time. The website can also display archival data and send alarms. I will present how we constructed these slow monitoring systems to be robust, accurate, and secure, while maintaining reliable access for the entire collaboration from any platform in order to ensure efficient communications and fast diagnoses of all CUORE systems.

  12. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  13. Measurement of Radon Concentration in Selected Houses in Ibadan, Nigeria

    Science.gov (United States)

    Usikalu, M. R.; Olatinwo, V.; Akpochafor, M.; Aweda, M. A.; Giannini, G.; Massimo, V.

    2017-05-01

    Radon is a natural radioactive gas without colour or odour and tasteless. The World Health Organization (WHO) grouped radon as a human lung carcinogen. For this reason, there has been a lot of interest on the effects of radon exposure to people all over the world and Nigeria is no exception. The aim of this study is to investigate the radon concentration in selected houses in three local government areas of Ibadan. The indoor radon was measured in both mud and brick houses. Fifty houses were considered from the three Local government areas. A calibrated portable continuous radon monitor type (RAD7) manufactured by Durridge company was used for the measurement. A distance of 100 to 200 m was maintained between houses in all the locations. The living room was kept closed during the measurements. The mean radon concentration measured in Egbeda is 10.54 ±1.30 Bqm -3; Lagelu is 16.90 ± 6.31 Bqm -3 and Ona-Ara is 17.95 ± 1.72 Bqm -3. The mean value of the annual absorbed dose and annual effective dose for the locations in the three local government areas was 0.19 mSvy-1 and 0.48 mSvy-1 respectively. The radon concentration for location 10 in Ono-Ara local government exceeded the recommended limit. However, the overall average indoor radon concentration of the three local governments was found to be lower than the world average value of 40 Bqm -3. Hence, there is need for proper awareness about the danger of radon accumulation in dwelling places.

  14. Radon og boligen

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    Radon er en radioaktiv og sundhedsskadelig luftart, som ved indånding øger risikoen for lungekræft. Der er ingen dokumenteret nedre grænse for, hvornår radon er ufarligt. Derfor anbefales det, at man tilstræber et så lavt radonindhold i indeluften som muligt. Man kan hverken lugte, se, høre eller...... smage radon, så vil du vide, om du har radon i din bolig, må du måle radonindholdet i indeluften. Radon forekommer naturligt i jorden og kan suges ind sammen med jordluft, hvis der inde er et undertryk, og hvis konstruktionerne mod jord er utætte. Jordluft trænger ind gennem revner og utætte samlinger......, fx omkring rør til kloak, vand og varmeforsyning. Koncentrationen af radon i jorden varierer meget fra sted til sted, også lokalt og gennem året. Tidligere undersøgelser har vist, at der kan forekomme høje koncentrationer i Sydgrønland, specielt i området syd for Narsalik ved Paamiut, 61°30’N....

  15. Radon diffusion through multilayer earthen covers: models and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, D.W.; Oster, C.A.; Nelson, R.W.; Gee, G.W.

    1981-09-01

    A capability to model and analyze the fundamental interactions that influence the diffusion of radon gas through uranium mill tailings and cover systems has been investigated. The purpose of this study is to develop the theoretical basis for modeling radon diffusion and to develop an understanding of the fundamental interactions that influence radon diffusion. This study develops the theoretical basis for modeling radon diffusion in one, two and three dimensions. The theory has been incorporated into three computer models that are used to analyze several tailings and cover configurations. This report contains a discussion of the theoretical basis for modeling radon diffusion, a discussion of the computer models used to analyze uranium mill tailings and multilayered cover systems, and presents the results that have been obtained.

  16. Calibration of scintillation cells for radon-222 measurements

    Science.gov (United States)

    Aakko, Kyllikki; Oksanen, Eero

    The calibration, of a radon-222 measurement system is described. The detector of the system is based on ZnS(Ag) coated scintillation cell. Evacuated cells are used for grab sample measurements of radon-222 in air. Three types of radioactive sources were used to evaluate the calibration coefficient. Standard activities were generated from commercially available solid and liquid radium-226 sources, and from a self-made radon-222 source whose activity was crosschecked by gamma spectrometric measurements. Radium-226 sources are traceable to US National Institute of Standards and Technology reference standards. Sources of error on calibration are discussed. Best accuracy was obtained by gamma spectrometrically crosschecked radon source. Considerable difficulties were encountered with the traditional method of emanating a known activity of radon-222 from a standard liquid radium-226 source. Three separate solid radium-226 sources gave results with rather large deviations. The final error weighted coefficients agree well with international intercalibration results.

  17. Quantile regression and Bayesian cluster detection to identify radon prone areas.

    Science.gov (United States)

    Sarra, Annalina; Fontanella, Lara; Valentini, Pasquale; Palermi, Sergio

    2016-11-01

    Albeit the dominant source of radon in indoor environments is the geology of the territory, many studies have demonstrated that indoor radon concentrations also depend on dwelling-specific characteristics. Following a stepwise analysis, in this study we propose a combined approach to delineate radon prone areas. We first investigate the impact of various building covariates on indoor radon concentrations. To achieve a more complete picture of this association, we exploit the flexible formulation of a Bayesian spatial quantile regression, which is also equipped with parameters that controls the spatial dependence across data. The quantitative knowledge of the influence of each significant building-specific factor on the measured radon levels is employed to predict the radon concentrations that would have been found if the sampled buildings had possessed standard characteristics. Those normalised radon measures should reflect the geogenic radon potential of the underlying ground, which is a quantity directly related to the geological environment. The second stage of the analysis is aimed at identifying radon prone areas, and to this end, we adopt a Bayesian model for spatial cluster detection using as reference unit the building with standard characteristics. The case study is based on a data set of more than 2000 indoor radon measures, available for the Abruzzo region (Central Italy) and collected by the Agency of Environmental Protection of Abruzzo, during several indoor radon monitoring surveys. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Radon background study in Super-Kamiokande

    Science.gov (United States)

    Nakano, Yuuki; Super-Kamiokande Collaboration

    2017-09-01

    Super-Kamiokande (SK), a 50 kton water Cherenkov detector in Japan, observes 8B solar neutrinos with neutrino-electron elastic scattering. SK searches for distortions of the solar neutrino energy spectrum caused by the edge of the MSW resonance in the core of the Sun. The installation of new front-end electronics in 2008 marks the beginning of the 4th phase of SK (SK-IV). With the improvement of the water circulation system, calibration methods, reduction cuts, this phase achieved the lowest energy threshold thus far (3.5 MeV kinetic energy). To improve the sensitivity to the MSW effect, it is required to achieve lower energy threshold. For this purpose, understanding the origin of background events and reducing them are important. Currently, the main background is known as a beta decay of 214Bi in a Radon decay chain. So far, SK collaboration has developed several techniques for studying Radon contamination in the SK water. In this proceedings, a measurement system which can measure Radon concentration in the SK water with the accuracy of 0.1 mBq/m3 level is presented. In addition, an evaluation of Radon background events in SK injecting Radon rich water into the SK tank, as well as future prospects are also presented.

  19. Radon in indoor air of primary schools: a systematic survey to evaluate factors affecting radon concentration levels and their variability.

    Science.gov (United States)

    Bochicchio, F; Žunić, Z S; Carpentieri, C; Antignani, S; Venoso, G; Carelli, V; Cordedda, C; Veselinović, N; Tollefsen, T; Bossew, P

    2014-06-01

    In order to optimize the design of a national survey aimed to evaluate radon exposure of children in schools in Serbia, a pilot study was carried out in all the 334 primary schools of 13 municipalities of Southern Serbia. Based on data from passive measurements, rooms with annual radon concentration >300 Bq/m(3) were found in 5% of schools. The mean annual radon concentration weighted with the number of pupils is 73 Bq/m(3), 39% lower than the unweighted 119 Bq/m(3) average concentration. The actual average concentration when children are in classrooms could be substantially lower. Variability between schools (CV = 65%), between floors (CV = 24%) and between rooms at the same floor (CV = 21%) was analyzed. The impact of school location, floor, and room usage on radon concentration was also assessed (with similar results) by univariate and multivariate analyses. On average, radon concentration in schools within towns is a factor of 0.60 lower than in villages and at higher floors is a factor of 0.68 lower than ground floor. Results can be useful for other countries with similar soil and building characteristics. On average, radon concentrations are substantially higher in schools in villages than in schools located in towns (double,on average). Annual radon concentrations exceeding 300 Bq/m3 were found in 5% of primary schools (generally on ground floors of schools in villages). The considerable variability of radon concentration observed between and within floors indicates a need to monitor concentrations in several rooms for each floor. A single radon detector for each room can be used provided that the measurement error is considerable lower than variability of radon concentration between rooms. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Radon as a natural geochemical tracer for study of groundwater discharge into lakes

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Axel

    2008-06-27

    In the presented work the suitability of the naturally occurring radioactive noble gas isotope radon-222 for qualitative and quantitative description of groundwater discharge into lakes was studied. Basis of these investigations was the development of two innovative techniques for the on-site determination of radon in water. In the ex-situ radon measurement procedure, water from the source concerned is taken up in an exchange cell used for this purpose. Inside this cell, the radon dissolved in water is transferred via diffusion into a closed counter-flow of air and subsequently detected by a radon-in-air monitor. Where the in-situ radon determination is concerned, a module composed of a semipermeable membrane is introduced into a water column. Subsequently, the radon dissolved in the water body diffuses through the membrane into the corresponding air flow, by means of which it is transferred into a radon-in-air monitor and is detected. Combination of the developed mobile radon extraction techniques with a suitable and portable radon monitor allow the detection of radon-222 with sufficient accuracy (smaller 20 %) in groundwater as well as in surface waters, i.e., within a broad range of concentrations. Radon-222 was subsequently used to characterize groundwater discharge into a meromictic and a dimictic lake, i.e. two types of lake basically distinct from each other with respect to their water circulation properties were investigated. The use of the noble gas isotope radon-222 as a geochemical tracer makes the application of on-site detection techniques possible and that this in turn permits a rapid, reliable, and cost-effective assessment of groundwater discharge rates into lake water bodies.

  1. Coastwide Reference Monitoring System (CRMS)

    Science.gov (United States)

    2010-01-01

    In 1990, the U.S. Congress enacted the Coastal Wetlands Planning, Protection and Restoration Act (CWPPRA) in response to growing awareness of a land loss crisis in Louisiana. Projects funded by CWPPRA require monitoring and evaluation of project effectiveness, and there is also a need to assess the cumulative effects of all projects to achieve a sustainable coastal environment. In 2003, the Louisiana Office of Coastal Protection and Restoration (OCPR) and the U.S. Geological Survey (USGS) received approval from the CWPPRA Task Force to implement the Coastwide Reference Monitoring System (CRMS) as a mechanism to monitor and evaluate the effectiveness of CWPPRA projects at the project, region, and coastwide levels. The CRMS design implements a multiple reference approach by using aspects of hydrogeomorphic functional assessments and probabilistic sampling. The CRMS program is as dynamic as the coastal habitats it monitors. The program is currently funded through CWPPRA and provides data for a variety of user groups, including resource managers, academics, landowners, and researchers.

  2. The dynamics of a double-cell hydrothermal system in triggering seismicity at Somma-Vesuvius: results from a high-resolution radon survey (revisited)

    Science.gov (United States)

    Cigolini, Corrado

    2010-08-01

    Data collected at Somma-Vesuvius during the 1998-1999 radon surveys have been revisited and reinterpreted in light of recent geophysical and geochemical information. The duration of selected radon anomalies, together with the decay properties of radon, have been used to estimate the permeability and porosity of rocks of the deep hydrothermal system. The current local cyclic seismicity is explained by means of a double convective-cell model. Convective cells are separated by a low-permeability horizon located at about 2-2.5 km below sea level. Fluids convecting within the upper cells show temperatures ranging 300-350°C. Rock permeabilities in this sector are estimated on the order of 10-12 m2, for porosities ( ϕ) of about 10-5 typical of a brittle environment where fluid velocities may reach ˜800 m/day. Fluid temperatures within the lower cells may be as high as 400-450°C, consistent with supercritical regimes. The hydrodynamic parameters for these cells are lower, with permeability k ˜ 10-15 m2, and porosity ranging from 10-6 to 10-7. Here, fluid motion toward the surface is controlled by the fracture network within a porous medium approaching brittle-ductile behaviour, and fluid velocities may reach ˜1,800 m/day. The low-permeability horizon is a layer where upper and lower convecting cells converge. In this region, fluids (convecting both at upper and lower levels) percolate through the wallrock and release their brines. Due to self-sealing processes, permeability within this horizon reaches critical values to keep the fluid pressure near lithostatic pressure (for k ˜ 10-18 m2). Deep fluid pressure buildups precede the onset of hydrothermally induced earthquakes. Permeability distribution and rock strength do not exclude that the next eruption at Somma-Vesuvius could be preceded by a seismic crisis, eventually leading to a precursory phreatic explosion. The coupling of these mechanisms has the potential of inducing pervasive failure within rocks of the

  3. Radon in land use planning; Radon i arealplanlegging

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-11-01

    Radon poses a health risk. Therefore, it is important that the municipality takes into account radon, in land use planning. This Radiation Info provides an overview of what makes an additional radon prone area and what tools are available to assess this. The background is the Planning and Building Act provisions on risk analysis (ROS) and zones. (eb)

  4. Radon measurements aboard the Kuiper Airborne Observatory

    Science.gov (United States)

    Kritz, Mark A.; Rosner, Stefan W.

    1995-01-01

    We have carried out three (piggyback) radon-related projects aboard the KAO. The first, which was limited to upper tropospheric measurements while in level flight, revealed the systematic occurrence of unexpectedly high radon concentrations in this region of the atmosphere. The second project was an instrument development project, which led to the installation of an automatic radon measurement system aboard the NASA ER-2 High Altitude Research Aircraft. In the third, we installed a new system capable of collecting samples during the normal climb and descent of the KAO. The results obtained in these projects have resulted in significant contributions to our knowledge of atmospheric transport processes, and are currently playing a key role in the validation of global circulation and transport models.

  5. Radon atlas of England and Wales

    Energy Technology Data Exchange (ETDEWEB)

    Green, B.M.R.; Miles, J.C.H.; Bradley, E.J.; Rees, D.M

    2002-07-01

    This new report brings together and updates the information in three earlier reports on radon levels in English and Welsh homes. In particular, data from measurements in over 400,000 homes in England and Wales are presented in tabular format. The tables give the data by various administrative divisions, down to electoral wards for Cornwall, Devon and Somerset and council areas elsewhere and to sector level of the postcode system. The radon probability maps are based on the national grid system and show significantly more locational detail than the previous publications, an extra division in the probability banding to coincide with current Government initiatives on radon in England and, in southwest England, more detailed probability mapping than before - by 1 km grid squares in place of the 5 km grid squares used in Wales and the rest of England. (author)

  6. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Directory of Open Access Journals (Sweden)

    Yun-Yun Wu

    2014-10-01

    Full Text Available 222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration.

  7. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Science.gov (United States)

    Wu, Yun-Yun; Ma, Yong-Zhong; Cui, Hong-Xing; Liu, Jian-Xiang; Sun, Ya-Ru; Shang, Bing; Su, Xu

    2014-01-01

    222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration. PMID:25350007

  8. Environmental Radon Gas and Degenerative Conditions An Overview

    Energy Technology Data Exchange (ETDEWEB)

    Groves-Kirkby, C.J. [Medical Physics Department, Northampton General Hospital, Northampton NN1 5BD (United Kingdom)]|[School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom); Denman, A.R. [Medical Physics Department, Northampton General Hospital, Northampton NN1 5BD (United Kingdom); Woolridge, A.C. [School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom)]|[School of Applied Sciences, University of Northampton, Northampton NN2 7AL (United Kingdom); Phillips, P.S. [School of Applied Sciences, University of Northampton, Northampton NN2 7AL (United Kingdom); Phillips, C. [School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom)

    2006-07-01

    Radon, a naturally occurring radioactive gas, has variable distribution in the environment as a decay product of uranium occurring in a wide range of rocks, soils and building materials. Although radon dissipates rapidly in outdoor air, it concentrates in the built environment, and inhalation of {sup 222}Rn and its progeny {sup 218}Po and {sup 214}Po is believed to provide the majority of the radioactive dose to the respiratory system. While the connection between radon and lung cancer has long been recognised and investigated, recent studies have highlighted potential links between radon and other conditions, among them Multiple Sclerosis, Alzheimer and Parkinson Diseases, and Paget Disease of Bone. A strong case exists for clarifying the relationship between radon and these other conditions, not least since radon remediation to reduce lung cancer may conceivably have additional benefits hitherto unrecognized. The present status of the postulated links between environmental radon gas and degenerative conditions is reviewed, and recommendations for further research into levering current anti-radon campaigns are made. (authors)

  9. Demonstration of radon removal from SF6 using molecular sieves

    Science.gov (United States)

    Ezeribe, A. C.; Lynch, W.; Gregorio, R. R. Marcelo; Mckeand, J.; Scarff, A.; Spooner, N. J. C.

    2017-09-01

    The gas SF6 has become of interest as a negative ion drift gas for use in directional dark matter searches. However, as for other targets in such searches, it is important that radon contamination can be removed as this provides a source of unwanted background events. In this work we demonstrate for the first time filtration of radon from SF6 gas by using a molecular sieve. Four types of sieves from Sigma-Aldrich were investigated, namely 3Å, 4Å, 5Å and 13X. A manufactured radon source was used for the tests. This was attached to a closed loop system in which gas was flowed through the filters and a specially adapted Durridge RAD7 radon detector. In these measurements, it was found that only the 5Å type was able to significantly reduce the radon concentration without absorbing the SF6 gas. The sieve was able to reduce the initial radon concentration of 3875 ± 13 Bqm-3 in SF6 gas by 87% when cooled with dry ice. The ability of the cooled 5Å molecular sieve filter to significantly reduce radon concentration from SF6 provides a promising foundation for the construction of a radon filtration setup for future ultra-sensitive SF6 gas rare-event physics experiments.

  10. Radon Mitigation Approach in a Laboratory Measurement Room

    Directory of Open Access Journals (Sweden)

    Patricia Blanco-Rodríguez

    2017-05-01

    Full Text Available Radon gas is the second leading cause of lung cancer, causing thousands of deaths annually. It can be a problem for people or animals in houses, workplaces, schools or any building. Therefore, its mitigation has become essential to avoid health problems and to prevent radon from interfering in radioactive measurements. This study describes the implementation of radon mitigation systems at a radioactivity laboratory in order to reduce interferences in the different works carried out. A large set of radon concentration samples is obtained from measurements at the laboratory. While several mitigation methods were taken into account, the final applied solution is explained in detail, obtaining thus very good results by reducing the radon concentration by 76%.

  11. Radon Mitigation Approach in a Laboratory Measurement Room.

    Science.gov (United States)

    Blanco-Rodríguez, Patricia; Fernández-Serantes, Luis Alfonso; Otero-Pazos, Alberto; Calvo-Rolle, José Luis; de Cos Juez, Francisco Javier

    2017-05-11

    Radon gas is the second leading cause of lung cancer, causing thousands of deaths annually. It can be a problem for people or animals in houses, workplaces, schools or any building. Therefore, its mitigation has become essential to avoid health problems and to prevent radon from interfering in radioactive measurements. This study describes the implementation of radon mitigation systems at a radioactivity laboratory in order to reduce interferences in the different works carried out. A large set of radon concentration samples is obtained from measurements at the laboratory. While several mitigation methods were taken into account, the final applied solution is explained in detail, obtaining thus very good results by reducing the radon concentration by 76%.

  12. Radon concentration levels in dwellings and mine atmospheres in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Pena, P. [Instituto Nacional de Investigaciones Nucleares, Mexico City (Mexico); Mireles, F.; Davila, I.; Quirino, L. [Universidad Autonoma de Zacatecas (Mexico). Centro Regional de Estudios Nucleares

    1993-12-31

    Atmospheric radon surveys have been conducted in dwellings and mine atmospheres from the city of Zacatecas and single family homes in Mexico City. The monitoring was performed with track detectors, LR115 type II. The radon concentration values in most of the atmospheres studied were less than 150 Bq/m{sup 3}; the maximum value at the top soil in mines reached 1200 Bq/m{sup 3}. (author).

  13. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-08-31

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed.

  14. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2004-10-13

    The deep hard rock drilling environment induces severe vibrations into the drillstring, which can cause reduced rates of penetration (ROP) and premature failure of the equipment. The only current means of controlling vibration under varying conditions is to change either the rotary speed or the weight-on-bit (WOB). These changes often reduce drilling efficiency. Conventional shock subs are useful in some situations, but often exacerbate the problems. The objective of this project is development of a unique system to monitor and control drilling vibrations in a ''smart'' drilling system. This system has two primary elements: (1) The first is an active vibration damper (AVD) to minimize harmful axial, lateral and torsional vibrations. The hardness of this damper will be continuously adjusted using a robust, fast-acting and reliable unique technology. (2) The second is a real-time system to monitor drillstring vibration, and related parameters. This monitor adjusts the damper according to local conditions. In some configurations, it may also send diagnostic information to the surface via real-time telemetry. The AVD is implemented in a configuration using magnetorheological (MR) fluid. By applying a current to the magnetic coils in the damper, the viscosity of the fluid can be changed rapidly, thereby altering the damping coefficient in response to the measured motion of the tool. Phase I of this program entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype. Phase I of the project was completed by the revised end date of May 31, 2004. The objectives of this phase were met, and all prerequisites for Phase II have been completed. The month of June, 2004 was primarily occupied with the writing of the Phase I Final Report, the sole deliverable of Phase I, which will be submitted in the next quarter. Redesign of the laboratory prototype and design of the downhole (Phase II) prototype was

  15. Order of the 22 July 2004 relative to the modalities of the management of the risk bond to radon in areas open to the public; Arrete du 22 juillet 2004 relatif aux modalites de gestion du risque lie au radon dans les lieux ouverts au public

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-08-15

    This text fixes the 17 articles concerning the attitudes and the risk management in the areas, presenting radon and open to the public. It concerns the monitoring and the procedure of radon management. (A.L.B.)

  16. {open_quotes}Radon{close_quotes} - the system of Soviet designed regional waste management facilities

    Energy Technology Data Exchange (ETDEWEB)

    Horak, W.C.; Reisman, A.; Purvis, E.E. III

    1997-07-01

    The Soviet Union established a system of specialized regional facilities to dispose of radioactive waste generated by sources other than the nuclear fuel cycle. The system had 16 facilities in Russia, 5 in Ukraine, one in each of the other CIS states, and one in each of the Baltic Republics. These facilities are still being used. The major generators of radioactive waste they process these are research and industrial organizations, medical and agricultural institution and other activities not related to nuclear power. Waste handled by these facilities is mainly beta- and gamma-emitting nuclides with half lives of less than 30 years. The long-lived and alpha-emitting isotopic content is insignificant. Most of the radwaste has low and medium radioactivity levels. The facilities also handle spent radiation sources, which are highly radioactive and contain 95-98 percent of the activity of all the radwaste buried at these facilities.

  17. Monitoring Systems for Hydropower Plants

    Directory of Open Access Journals (Sweden)

    Damaschin Pepa

    2015-07-01

    Full Text Available One of the most important issue in hydro power industry is to determine the necessary degree of automation in order to improve the operation security. Depending upon the complexity of the system (the power plant equipment the automation specialist will build a philosophy of control following some general principals of security and operation. Helped by the modern digital equipment, today is relative easy to design a complete monitoring and supervising system including all the subparts of a hydro aggregate. A series of sensors and transducers specific for each auxiliary installation of the turbine and generator will be provided, together with a PLC or an industrial PC that will run an application software for implementing the security and control algorithms. The purpose of this paper is to offer a general view of these issues, providing a view of designing an automation & control and security system for hydro power plants of small, medium and big power.

  18. Remote Environmental Monitoring System CRADA

    Energy Technology Data Exchange (ETDEWEB)

    Hensley, R.D.

    2000-03-30

    The goal of the project was to develop a wireless communications system, including communications, command, and control software, to remotely monitor the environmental state of a process or facility. Proof of performance would be tested and evaluated with a prototype demonstration in a functioning facility. AR Designs' participation provided access to software resources and products that enable network communications for real-time embedded systems to access remote workstation services such as Graphical User Interface (GUI), file I/O, Events, Video, Audio, etc. in a standardized manner. This industrial partner further provided knowledge and links with applications and current industry practices. FM and T's responsibility was primarily in hardware development in areas such as advanced sensors, wireless radios, communication interfaces, and monitoring and analysis of sensor data. This role included a capability to design, fabricate, and test prototypes and to provide a demonstration environment to test a proposed remote sensing system. A summary of technical accomplishments is given.

  19. In-soil radon anomalies as precursors of earthquakes: a case study in the SE slope of Mt. Etna in a period of quite stable weather conditions.

    Science.gov (United States)

    Vizzini, Fabio; Brai, Maria

    2012-11-01

    In-soil radon concentrations as well as climatic parameters (temperature, atmospheric pressure and relative humidity) were collected in St. Venerina (Eastern Sicily - Italy) from March 19th to May 22nd 2009, close to an active fault system called Timpe Fault System (TFS), which is strictly linked to the geodynamics of Mt. Etna. During the monitoring period no drastic climatic variations were observed and, on the other hand, important seismic events were recorded close to the monitoring site. A seismic swarm composed of 5 earthquakes was observed in the Milo area on March 25th (M(max) = 2.7) at just 5.1 km from the site, and on May 13th an earthquake of 3.6 magnitude was recorded in the territory of St. Venerina, at just 3.2 km from the site; the earthquake was felt by the population and reported by all local and regional media. The in-soil radon concentrations have shown anomalous increases possibly linked to the earthquakes recorded, but certainly not attributable to local meteorology. To verify this assumption the average radon concentration and the standard deviation (σ) have been calculated and the regions of ±1.5σ and ±2σ deviation from the average concentration have been investigated. Moreover, to further minimise the contribution of the meteorological parameters on the in-soil radon fluctuations, a multiple regressions method has been used. To distinguish those earthquakes which could generate in-soil radon anomalies as precursors, the Dobrovolsky radius has been applied. The results obtained suggests that a clear correlation between earthquakes and in-soil radon increases exist, and that the detection of the in-soil radon anomalies becomes surely simpler in particular favourable conditions: weather stability, earthquakes within the Dobrovolsky radius and close to the monitoring area. Moreover, the absence of large variations of the climatic parameters, which could generate incoherent noise components to the radon signal, has made the radon fluctuations

  20. Standardised Radon Index (SRI: a normalisation of radon data-sets in terms of standard normal variables

    Directory of Open Access Journals (Sweden)

    R. G. M. Crockett

    2011-07-01

    Full Text Available During the second half of 2002, from late June to mid December, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in the English East Midlands. This period included the Dudley earthquake (ML = 5, 22 September 2002 and also a smaller earthquake in the English Channel (ML = 3, 26 August 2002. Rolling/sliding windowed cross-correlation of the paired radon time-series revealed periods of simultaneous similar radon anomalies which occurred at the time of these earthquakes but at no other times during the overall radon monitoring period. Standardising the radon data in terms of probability of magnitude, analogous to the Standardised Precipitation Indices (SPIs used in drought modelling, which effectively equalises different non-linear responses, reveals that the dissimilar relative magnitudes of the anomalies are in fact closely equiprobabilistic. Such methods could help in identifying anomalous signals in radon – and other – time-series and in evaluating their statistical significance in terms of earthquake precursory behaviour.

  1. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  2. Radon: a bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given.

  3. Radon in Ingleborough / Clapham Cave, North Yorkshire, UK.

    Science.gov (United States)

    Gillmore, Gavin

    2015-04-01

    Atmospheric radon concentration was measured at Ingleborough Cave, North Yorkshire during the summer of 2004, and the autumn / winter of 2004/5. Significantly, Ingleborough Cave forms part of a larger system which includes the world famous Gaping Gill pothole. This plunges 105 m (334 ft), contains the tallest unbroken waterfall in England and one of the largest known underground chambers in the UK. Measurements were taken to assess the effects of seasonal and spatial variation, elevation and ventilation on radon concentration in Ingleborough. In this study personal dose exposures for three groups of cave user were identified, and the performance of a variety of radon detection systems evaluated. Summer radon concentrations inside the cave peaked at around 7,000 Bq m-3, although average concentrations were less than 5,000 Bq m-3. During the winter measurement period, average concentrations were around 100 Bq m-3, and a winter / summer ration therefore of 47,4. The average annual radon concentration exceeded the legislative limitations for the workplace of 400 Bq m-3 due in part to a failed fan in the ventilation system. When the fan was running we noted an 80% reduction in radon concentrations although reliability of the fan was problematic due to extensive but relatively rare flooding of the cave system. The radon dose experienced by cave workers and guides in this study exceeded the Ionisation Radiation Regulations limit of 5 mSv/annum, and highlighted that for health and safety reasons the ventilation system should be fully operational during the high radon concentration summer months. Keywords: Radon, Cave, Ingleborough, Detection methods

  4. Long-term radon variations at a hot spring in China

    Science.gov (United States)

    Yan, Rui; Woith, Heiko; Wang, Rongjiang; Wang, Guangcai

    2017-04-01

    Radon concentration is monitored continuously in mainland China by China Earthquake Administration (CEA) for the purpose of earthquake prediction. An almost gap-free radon record of nearly 40 years (from April 1976 to December 2015) of monitoring of water-dissolved radon at the hot spring site of BangLazhang (BLZ), Southwestern China is analysed. The length of the time series allows the investigation of long-term periodicities of radon. Ancillary observation data, i.e. water temperature, spring discharge rate, barometric pressure, combined with regional rainfall, galactic cosmic ray (as a proxy for solar activity) and regional seismicity are complemented for the same period to identify potentially influencing factors controlling the changes of radon. The long-term variations in radon concentration and ancillary observation data are studied by using the continuous Wavelet Power Spectrum (WPS), Wavelet Coherence (WTC), and Partial Wavelet Coherence (PWC) methods. The results of WPSs and WTCs show that the long-periodic radon concentration is characterized by a significant decadal cycle, matching well with the concurrent periodicity in water temperature, spring discharge rate, and galactic cosmic ray. The analysis of PWCs among radon, discharge rate, water temperature, and galactic cosmic ray reveals that the 11-year solar cycle might influence radon, water temperature, and spring discharge, though a direct physical link between the solar activity and the monitored parameters seems unlikely. Moreover, PWCs of radon, discharge rate and water temperature suggests that water temperature variations explain most of the coherent variability of radon and the discharge rate. Possible mechanisms are discussed. We tentatively propose that the multi-year periodic variations in radon concentration are mainly explained by variations of water temperature and/or spring discharge, which are modified and inter-modulated by earthquakes and decadal variations of unknown origin.

  5. Radon assay for SNO+

    Energy Technology Data Exchange (ETDEWEB)

    Rumleskie, Janet [Laurentian University, Greater Sudbury, Ontario (Canada)

    2015-12-31

    The SNO+ experiment will study neutrinos while located 6,800 feet below the surface of the earth at SNOLAB. Though shielded from surface backgrounds, emanation of radon radioisotopes from the surrounding rock leads to back-grounds. The characteristic decay of radon and its daughters allows for an alpha detection technique to count the amount of Rn-222 atoms collected. Traps can collect Rn-222 from various positions and materials, including an assay skid that will collect Rn-222 from the organic liquid scintillator used to detect interactions within SNO+.

  6. Evolutionary Autonomous Health Monitoring System (EAHMS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For supporting NASA's Robotics, Tele-Robotics and Autonomous Systems Roadmap, we are proposing the "Evolutionary Autonomous Health Monitoring System" (EAHMS) for...

  7. Radon as a natural tracer for underwater cave exploration.

    Science.gov (United States)

    Csondor, Katalin; Erőss, Anita; Horváth, Ákos; Szieberth, Dénes

    2017-07-01

    The Molnár János cave is one of the largest hypogenic caves of the Buda Thermal Karst (Budapest, Hungary) and mainly characterized by water-filled passages. The major outflow point of the waters of the cave system is the Boltív spring, which feeds the artificial Malom Lake. Previous radon measurements in the cave system and in the spring established the highest radon concentration (71 BqL(-1)) in the springwater. According to previous studies, the origin of radon was identified as iron-hydroxide containing biofilms, which form where there is mixing of cold and thermal waters, and these biofilms efficiently adsorb radium from the thermal water component. Since mixing of waters is responsible for the formation of the cave as well, these iron-hydroxide containing biofilms and the consequent high radon concentrations mark the active cave forming zones. Based on previous radon measurements, it is supposed that the active mixing and cave forming zone has to be close to the spring, since the highest radon concentration was measured there. Therefore radon mapping was carried out with the help of divers in order to get a spatial distribution of radon in the cave passages closest to the spring. Based on our measurements, the highest radon activity concentration (84 BqL(-1)) was found in the springwater. Based on the distribution of radon activity concentrations, direct connection was established between the spring and the István-room of the cave, which was verified by an artificial tracer. However, the distribution of radon in the cave passages shows lower concentrations (18-46 BqL(-1)) compared to the spring, therefore an additional deep inflow from hitherto unknown cave passages is assumed, from which waters with high radon content arrive to the spring. These passages are assumed to be in the active cave formation zone. This study proved that radon activity concentration distribution is a useful tool in underwater cave exploration. Copyright © 2016 Elsevier Ltd. All

  8. RADON CONCENTRATIONS IN UNDERGROUND DRINKING WATER IN PARTS OF CITIES, CHINA.

    Science.gov (United States)

    Wu, Yunyun; Cui, Hongxing; Liu, Jianxiang; Shang, Bing; Su, Xu

    2017-08-31

    222Rn concentrations in underground drinking water samples in 12 cities from seven provinces (municipalities), China were determined by using a continuous radon monitor with air-water exchanger. A total of 73 underground water samples were collected. The observed radon levels were in a range of 1.0-63.8 Bq l-1, with a mean of 11.8 Bq l-1. The annual effective dose from inhalation of water-borne radon for average radon content in underground water was 72.6 μSv and for maximal observed radon concentration in underground water the corresponding dose was 393.8 μSv. The dose contribution of inhalation dose from water-borne radon should be paid attention in some granitic area. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. The ingestible thermal monitoring system

    Science.gov (United States)

    Cutchis, Protagoras N.; Hogrefe, Arthur F.; Lesho, Jeffery C.

    1988-03-01

    A thermal monitoring system for measuring body core temperatures was developed that contains an ingestible pill which is both commandable and rechargeable, and which uses magnetic induction for command and telemetry as well as for recharging. The pill electronics consist of a battery power source, a crystal-controlled oscillator that drives a small air coil, and a command detection circuit. The resulting 262-kHz magnetilc field can be easily detected from a distance of 1 m. The pill oscillator functions at voltages less than 1 V, supplied by a single Ni-Cd battery, which must be recharged after 72 h of continuous transmission. The pill can be recalibrated periodically to compensate for long-term drift.

  10. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  11. Publications about Radon

    Science.gov (United States)

    There is no known safe level of exposure to radon. EPA strongly recommends that you fix your home if your test shows 4 picocuries (pCi/L) or more. These publications and resources will provide you with the information you need to fix your home.

  12. A brief overview on radon measurements in drinking water.

    Science.gov (United States)

    Jobbágy, Viktor; Altzitzoglou, Timotheos; Malo, Petya; Tanner, Vesa; Hult, Mikael

    2017-07-01

    The aim of this paper is to present information about currently used standard and routine methods for radon analysis in drinking waters. An overview is given about the current situation and the performance of different measurement methods based on literature data. The following parameters are compared and discussed: initial sample volume and sample preparation, detection systems, minimum detectable activity, counting efficiency, interferences, measurement uncertainty, sample capacity and overall turnaround time. Moreover, the parametric levels for radon in drinking water from the different legislations and directives/guidelines on radon are presented. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Basement radon entry and stack driven moisture infiltration reduced by active soil depressurization

    Science.gov (United States)

    C.R. Boardman; Samuel V. Glass

    2015-01-01

    This case study presents measurements of radon and moisture infiltration from soil gases into the basement of an unoccupied research house in Madison, Wisconsin, over two full years. The basement floor and exterior walls were constructed with preservative-treated lumber and plywood. In addition to continuous radon monitoring, measurements included building air...

  14. A Multiagent System for Monitoring Health

    NARCIS (Netherlands)

    van Moergestel, L.; van der Bijl, B.; Puik, E.; Telgen, D.H.|info:eu-repo/dai/nl/380243350; Meyer, J.J.C.|info:eu-repo/dai/nl/07139656X

    2016-01-01

    By using agent technology, a versatile and modular monitoring system can be built. In this paper, such a multiagent-based monitoring system will be described. The system can be trained to detect several conditions in combination and react accordingly. Because of the distributed nature of the system,

  15. Radon Resources for Home Buyers and Sellers

    Science.gov (United States)

    ... a Home Radon-Resistant New Construction Radon and Real Estate Resources Home Buyer's/Seller's Guide to Radon Consumer's ... Water A-Z Index Laws & Regulations By Business Sector By Topic Compliance Enforcement Laws and Executive Orders ...

  16. Spatial distribution of the radon concentration in soil and subterranean water in the Nuclear Center of Mexico and its surrounding using a geographical information system; Distribucion espacial de la concentracion de radon en suelo y agua subterranea en el Centro Nuclear de Mexico y sus alrededores utilizando un sistema de informacion geografica

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, S.; Pena, P.; Lopez, M.B.E.; Balcazar, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Madrigal, D. [UAEM, Facultad de Geografia, 50000 Toluca, estado de Mexico (Mexico)

    2003-07-01

    The radon concentration in soil of the Nuclear Center of Mexico using solid detectors of nuclear traces (LR 115, type ll) and in water of two aquifers of the Asuncion Tepexoyuca, by means of the liquid scintillation technique it was determined; both places located in the Ocoyoacac municipality, Estado de Mexico. The analysis of spatial distribution it was supported by means of a Geographic Information System. The results of the radon concentration in soil, they registered an average of 2. 64 kBq m{sup -3} in the study area, the more high average value it was of 5. 25 kBq m{sup -3} in the station 12-ZM (Military Area) and the minimum value was of 0. 54 kBq m{sup -3} in the point 7-CO (Dining room). In the radon concentration in water of La Perita it was observed an average value 0.52 Bq L{sup -1} and in El Tunel it was of 0.7 Bq L{sup -1}. (Author)

  17. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2006-01-17

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. Work during this quarter centered on the testing of the rebuilt laboratory prototype and its conversion into a version that will be operable in the drilling tests at TerraTek Laboratories. In addition, formations for use in these tests were designed and constructed, and a test protocol was developed. The change in scope and no-cost extension of Phase II to January, 2006, described in our last report, were approved. The tests are scheduled to be run during the week of January 23, and should be completed before the end of the month.

  18. Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    Science.gov (United States)

    Gross, Eliza L.

    2017-05-11

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont

  19. Monitored Geologic Repository Operations Monitoring and Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    E.F. Loros

    2000-06-29

    The Monitored Geologic Repository Operations Monitoring and Control System provides supervisory control, monitoring, and selected remote control of primary and secondary repository operations. Primary repository operations consist of both surface and subsurface activities relating to high-level waste receipt, preparation, and emplacement. Secondary repository operations consist of support operations for waste handling and treatment, utilities, subsurface construction, and other selected ancillary activities. Remote control of the subsurface emplacement operations, as well as, repository performance confirmation operations are the direct responsibility of the system. In addition, the system monitors parameters such as radiological data, air quality data, fire detection status, meteorological conditions, unauthorized access, and abnormal operating conditions, to ensure a safe workplace for personnel. Parameters are displayed in a real-time manner to human operators regarding surface and subsurface conditions. The system performs supervisory monitoring and control for both important to safety and non-safety systems. The system provides repository operational information, alarm capability, and human operator response messages during emergency response situations. The system also includes logic control to place equipment, systems, and utilities in a safe operational mode or complete shutdown during emergency response situations. The system initiates alarms and provides operational data to enable appropriate actions at the local level in support of emergency response, radiological protection response, evacuation, and underground rescue. The system provides data communications, data processing, managerial reports, data storage, and data analysis. This system's primary surface and subsurface operator consoles, for both supervisory and remote control activities, will be located in a Central Control Center (CCC) inside one of the surface facility buildings. The system

  20. Legal issues in radon affairs

    Energy Technology Data Exchange (ETDEWEB)

    Massuelle, M.H. [Inst. de Protection et de Surete Nucleaire, Fontenay aux Roses (France)

    1999-12-01

    In France, it was only recently that cases related to high radon concentrations in dwellings received substantial publicity. This irruption of radon as a public health issue came with the general progress of scientific knowledge and the availability of a research capacity in France able to develop expertise. We are interested here in the legal implications of issues that arise from the lag between the activity of expertsand the regulatory activity in the domain of radon. We use the term expertise very broadly, to cover the practical application of research findings, the relation of the researchers with the community, and finally the acts by which experts provide their knowledge to the community. We first examine the course by which science developed the radon issue and the way they organized to move from research to expertise; here we try to characterize the various needs for radon expertise. We then discuss the legal difficulties associated with radon expertise.

  1. Active system monitoring applied on wind turbines

    DEFF Research Database (Denmark)

    Niemann, Hans Henrik; Poulsen, Niels Kjølstad; Parbo, Henrik

    2009-01-01

    A concept for active system monitoring (ASM) applied on wind turbines is presented in this paper. The concept is based on an injection of a small periodic auxiliary signal in the system. An investigation of the signature from the auxiliary input in residual (error) signals can then be applied...... for an online monitoring of central parameters/elements of the system. Statistical tests are applied on the residual signals for obtaining a correct monitoring....

  2. Production monitoring system for understanding product robustness

    DEFF Research Database (Denmark)

    Boorla, Srinivasa Murthy; Howard, Thomas J.

    2016-01-01

    study is used to demonstrate how the monitoring system can be used to efficiently guide corrective action to improve product performance. It is claimed that the monitoring system can be used to dramatically cut the time taken to identify, planand execute corrective action related to typical quality...... to be seven days. Using the monitoring system for the PRECI‐IN case, similar corrective action would have been achieved almost immediately....

  3. Low-cost Radon Reduction Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rose, William B. [Univ. of Illinois, Urbana-Champaign, IL (United States); Francisco, Paul W. [Univ. of Illinois, Urbana-Champaign, IL (United States); Merrin, Zachary [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2015-09-01

    The U.S. Department of Energy's Building America research team Partnership for Advanced Residential Retrofits conducted a primary scoping study on the impact of air sealing between the foundation and the living space on radon transport reduction across the foundation and living space floor assembly. Fifteen homes in the Champaign, Illinois, area participated in the study. These homes were instrumented for hourly continuous radon measurements and simultaneous temperature and humidity measurements. Blower door and zone pressure diagnostics were conducted at each house. The treatments consisted of using air-sealing foams at the underside of the floor that separated the living space from the foundation and providing duct sealing on the ductwork that is situated in the foundation area. The hypothesis was that air sealing the floor system that separated the foundation from the living space should better isolate the living space from the foundation; this isolation should lead to less radon entering the living space from the foundation. If the hypothesis had been proven, retrofit energy-efficiency programs may have chosen to adopt these isolation methods for enhanced radon protection to the living space.

  4. The influence of thoron on measurement results of radon exhalation rate

    CERN Document Server

    Xiao De Tao; Ling Qiu; Leung, J K C

    2002-01-01

    Because of thoron exhalation, the measurement results of radon exhalation rate using a local still method is usually larger than the true value of radon flux rate of the monitored material surface. The influence of sup 2 sup 1 sup 6 Po(ThA) on radon exhalation rate can be eliminated for sensitive radon monitors. Theoretical evaluations of the influence of sup 2 sup 1 sup 2 Bi(ThC) and sup 2 sup 1 sup 2 Po(ThC')on radon exhalation rate are carried out in a sampler with diameter of 188 mm, and height of 125 mm, and supplied electrostatic field inside (generated by high voltage and electret) under following conditions: the sampling time are 1, 2, 3 h, respectively, thoron exhalation rate is 100 times of radon's. The calculation results indicate that the measurement results of radon flux rate are possibly 35.5% larger than true value due to the influence of thoron for fast and multifunctional radon monitors with electret, high voltage, respectively and using CR-39 SSNTD as detector, but this influence is negligib...

  5. Coma Patient Monitoring System Using Image Processing

    Science.gov (United States)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  6. DOWNHOLE VIBRATION MONITORING & CONTROL SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2005-04-27

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. The principal objectives of Phase II are: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in drilling laboratories and test wells. As a result of the lower than expected performance of the MR damper noted last quarter, several additional tests were conducted. These dealt with possible causes of the lack of dynamic range observed in the testing: additional damping from the oil in the Belleville springs; changes in properties of the MR fluid; and, residual magnetization of the valve components. Of these, only the last was found to be significant. By using a laboratory demagnetization apparatus between runs, a dynamic range of 10:1 was achieved for the damper, more than adequate to produce the needed improvements in drilling. Additional modeling was also performed to identify a method of increasing the magnetic field in the damper. As a result of the above, several changes were made in the design. Additional circuitry was added to demagnetize the valve as the field is lowered. The valve was located to above the Belleville springs to reduce the load placed upon it and offer a greater range of materials for its construction. In addition, to further increase the field strength, the coils were relocated from the mandrel to the outer housing. At the end of the quarter, the redesign was complete and new parts were on order. The project is approximately three months behind schedule at this time.

  7. Radon in soil concentration levels in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Tamez, E.; Mena, M

    1991-09-15

    Radon in soil surveys in Mexico have been carried out since 1974 both for uranium prospectus and to correlate mean values of the gas emanation with local telluric behaviour. The mapping includes the northern uranium mining region, the Mexican Neo volcanic Belt, the coastal areas adjacent to the zone of subduction of the Cocos Plate under the North American Plate, some of the active volcanoes of Southern Mexico and several sedimentary valleys in Central Mexico. Recording of {sup 222} Rn alpha decay is systematically performed with LR115 track detectors. Using mean values averaged over different observation periods at fixed monitoring stations, a radon in soil map covering one third of the Mexican territory is presented. The lowest mean values have been found in areas associated with active volcanoes. The highest levels are found in uranium ore zones. Intermediate values are obtained in regions with enhanced hydrothermal activity and stations associated with intrusive rocks. (Author)

  8. Design and Development of Patient Monitoring System

    Science.gov (United States)

    Hazwanie Azizulkarim, Azra; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    Patient monitoring system allows continuous monitoring of patient vital signs, support decision making among medical personnel and help enhance patient care. This system can consist of devices that measure, display and record human’s vital signs, including body temperature, heart rate, blood pressure and other health-related criteria. This paper proposes a system to monitor the patient’s conditions by monitoring the body temperature and pulse rate. The system consists of a pulse rate monitoring software and a wearable device that can measure a subject’s temperature and pulse rate only by using a fingertip. The device is able to record the measurement data and interface to PC via Arduino microcontroller. The recorded data can be viewed as a historical file or can be archived for further analysis. This work also describes the preliminary experimental results of the selected sensors to show the usefulness of the sensors for the proposed patient monitoring system.

  9. Comparative analysis of solar photovoltaic monitoring systems

    Science.gov (United States)

    Madeti, Siva Ramakrishna; Singh, S. N.

    2017-07-01

    This paper is focused on comparative analysis of photovoltaic (PV) monitoring system for observing the performance and stability of the system. The cost and complexity of existing PV monitoring systems restricted their use to large scale PV plants. Over the past decade, different aspects of the PV monitoring systems were reported in the wide range of literature. In this paper, a comparative analysis of various PV monitoring systems is presented for the first time. It is based on analyzing six main characteristics of PV monitoring system, such as data transfer mechanism, controller, monitoring parameters, sampling interval, program development software and monitoring methods. The comparison of methodologies and the description of implementation process are discussed in this context. The key findings of this study will contribute to the development of a new PV monitoring system. The acquaintance of all these aspects is crucial for the development of effective, low cost, and viable PV monitoring systems for the small and medium scale PV plants without compromising on the desired performance.

  10. Soil gas radon measurements around Mt. Etna volcano in terms of evaluation of geodynamic events

    Science.gov (United States)

    Immè, Giuseppina; Catalano, Roberto; Giammanco, Salvatore; Ichedef, Mutlu; Neri, Marco; Morelli, Daniela; Murè, Filippo; Giudice, Nunzio

    2017-04-01

    Soil gas radon measurements were performed continuously in the east flank of Mt. Etna since July 2015 volcano in order to correlate soil gas radon anomalies with local geodynamic processes. Both volcanic activity and seismic monitoring have been carried out by means of seismic stations and video-cameras located around the volcano, while the evaluation of radon data has been done using basic statistics and signal processing methods. Preliminary analysis of data seems to indicate a clear correlation between soil gas radon variations and volcanic activity of Mt. Etna, being the November 2015 and May 2016 eruptions preceded by marked anomalous variations (mainly decreases) of radon levels in all monitoring stations. Further anomalies have been recognized since November 2016, which may suggest new arrival of fresh magma into the volcano, possibly leading to future eruptions.

  11. Evaluation of the open vial method in the radon measurement; Evaluacion del metodo del vial abierto en la medicion de radon

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  12. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  13. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  14. PEM fuel cell monitoring system

    Science.gov (United States)

    Meltser, Mark Alexander; Grot, Stephen Andreas

    1998-01-01

    Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

  15. Infinite measure~preserving~transformations with Radon MSJ

    OpenAIRE

    Danilenko, Alexandre I.

    2015-01-01

    We introduce concepts of Radon MSJ and Radon disjointness for infinite Radon measure preserving homeomorphisms of the locally compact Cantor space. We construct an uncountable family of pairwise Radon disjoint infinite Chacon like transformations. Every such transformation is Radon strictly ergodic, totally ergodic, asymmetric (not isomorphic to its inverse), has Radon MSJ and possesses Radon joinings whose ergodic components are not joinings.

  16. Modernizing the monitoring of Mass Storage systems

    CERN Document Server

    Terrien, Alexandre

    2016-01-01

    The monitoring of a system is essential to ensure its efficiency. On a computer system, this monitoring is partly done via the analysis of log messages. The monitoring of CASTOR, a mass-storage system responsible for the storage of 150Pb of scientific data at CERN, was being done with tools developed by the IT-ST-FDO section. Those tools recently encountered some performance limitations due to the increase in the quantity of data produced by CERN's experiments. In this paper, I will describe how I managed to modernize CASTOR's monitoring tools by leveraging services centrally managed by CERN's IT department.

  17. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  18. Developing a system for AMB Monitoring

    CERN Document Server

    Hancock, Thomas

    2015-01-01

    A monitoring system for the Associative Memory Boards (AMBs) of the Fast Tracker (FTK) is developed and tested. This system is able to read out status register values from AMBs and publish them to the Information Service (IS). The system is designed so as to be easily extensible to other boards of FTK, and this is demonstrated through an extension of the systems to be able to monitor FTK Auxiliary cards. Future work will involve extensions to other FTK boards and providing a system to read from IS and present the user with the monitoring data.

  19. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  20. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G.; Golzarri, J. I.; Lopez, K.; Rickards, J., E-mail: espinosa@fisica.unam.m [UNAM, Instituto de Fisica, Apdo. Postal 20-364, 01000 Mexico D. F. (Mexico)

    2011-02-15

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Physics Institute 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as incidental users; and c) establish, if necessary, time limits for continuous permanence on the location for indoor radon exposure. Passive nuclear track detectors and dynamic systems were employed, covering six months (August, 2009 to January, 2010). For the calculation of internal dose the Radon Individual Dose Calculator was used. The results indicate that the indoor radon levels are below the US EPA recommended levels (400 Bq/m{sup 3}) in workplaces. The measurements help to establish levels for workplaces in Mexico. (Author)

  1. Modeling and experimental examination of water level effects on radon exhalation from fragmented uranium ore.

    Science.gov (United States)

    Ye, Yong-Jun; Dai, Xin-Tao; Ding, De-Xin; Zhao, Ya-Li

    2016-12-01

    In this study, a one-dimensional steady-state mathematical model of radon transport in fragmented uranium ore was established according to Fick's law and radon transfer theory in an air-water interface. The model was utilized to obtain an analytical solution for radon concentration in the air-water, two-phase system under steady state conditions, as well as a corresponding radon exhalation rate calculation formula. We also designed a one-dimensional experimental apparatus for simulating radon diffusion migration in the uranium ore with various water levels to verify the mathematical model. The predicted results were in close agreement with the measured results, suggesting that the proposed model can be readily used to determine radon concentrations and exhalation rates in fragmented uranium ore with varying water levels. Copyright © 2016. Published by Elsevier Ltd.

  2. Soil radon survey to assess NAPL contamination from an ancient spill. Do kerosene vapors affect radon partition ?

    Science.gov (United States)

    De Simone, Gabriele; Lucchetti, Carlo; Pompilj, Francesca; Galli, Gianfranco; Tuccimei, Paola; Curatolo, Pierpaolo; Giorgi, Riccardo

    2017-05-01

    A soil radon-deficit survey was carried out in a site polluted with kerosene (Rome, Italy) in winter 2016 to assess the contamination due to the NAPL residual component in the vadose zone and to investigate the role of the vapor plume. Radon is indeed more soluble in the residual NAPL than in air or water, but laboratory experiments demonstrated that it is also preferentially partitioned in the NAPL vapors that transport it and may influence soil radon distribution patterns. Specific experimental configurations were designed and applied to a 31-station grid to test this hypothesis; two RAD7 radon monitors were placed in-series and connected to the top of a hollow probe driven up to 80-cm depth; the first instrument was directly attached to the probe and received humid soil gas, which was counted and then conveyed to the second monitor through a desiccant (drierite) cylinder capturing moisture and eventually the NAPL volatile component plus the radon dissolved in vapors. The values from the two instruments were cross-calibrated through specifically designed laboratory experiments and compared. The results are in agreement within the error range, so the presence of significant NAPL vapors, eventually absorbed by drierite, was ruled out. This is in agreement with low concentrations of soil VOCs. Accordingly, the radon-deficit is ascribed to the residual NAPL in the soil pores, as shown very well also by the obtained maps. Preferential areas of radon-deficit were recognised, as in previous surveys. An average estimate of 21 L (17 Kg) of residual NAPL per cubic meter of terrain is provided on the basis of original calculations, developed from published equations. A comparison with direct determination of total hydrocarbon concentration (23 kg per cubic meter of terrain) is provided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Sport monitoring with smart wearable system.

    Science.gov (United States)

    Perego, Paolo; Moltani, Alessia; Andreoni, Giuseppe

    2012-01-01

    This work presents a new system for sport monitoring. The system was composed of a t-shirt with two textile electrodes and two devices for the acquisition, storage, processing and visualization of the signals. The systems allows monitoring both ECG signal (raw and processed heart-rate) and 3 axial acceleration (raw and step counter). The systems were tested in different conditions during some races; we report the results on three subjects during a skyrunning race.

  4. The design of remote temperature monitoring system

    Science.gov (United States)

    Li, Biqing; Li, Zhao; Wei, Liuren

    2017-08-01

    This design is made on the basis of the single-chip microcomputer remote temperature monitoring system. STC89C51RC is the main core part, this design use the sensor DHT11 of temperature or humidity and wireless transceiver NRF24L01 the temperature of the test site for long-range wireless measurement and monitoring. The design contains the main system and the small system, of which the main system can show the actual test site temperature and humidity values, voice broadcast, out of control and receive data alarm function; The small system has the function of temperature and humidity, temperature monitoring and sending data. After debugging, the user customizable alarm upper and lower temperature, when the temperature exceeds limit value, the main system of buzzer alarm immediately. The system has simple structure, complete functions and can alarm in time, it can be widely used remote temperature acquisition and monitoring of the site.

  5. Radon Infiltration in Rented Accommodation

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2017-01-01

    Indoor radon levels were measured in 221 homes located in 53 buildings, including 28 multi-occupant houses and 25 single-family terraced houses. The homes consisted of rented accommodation located in buildings recorded as being constructed before 2010 and after the year 1850. The radon level...

  6. Radon - The management of the risk related to radon; Le radon la gestion du risque lie au radon

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This leaflet briefly explains what radon is, where it comes from, and what it becomes. It indicates and briefly comments its concentrations in French departments, describes how radon can affect our health (lung cancer), describes how the risk can be reduced in buildings, and indicates the existing regulatory provisions

  7. Surveillance system for radiation monitoring in HTTR

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Takashi; Yasu, Katsuji; Yoshino, Toshiaki; Ashikagaya, Yoshinobu; Kikuchi, Toshiki; Minowa, Yuuji [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Sato, Kouichi; Nomura, Toshibumi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2001-03-01

    The High Temperature Engineering Test Reactor (HTTR: thermal output of 30 MW) went critical for the first time on November 10, 1998. Radiation monitoring in the HTTR Rise-to-Power Test was carried out using the surveillance system. This report will be used in radiation monitoring in Rise-to-Power Tests and also in periodic inspection work etc. in HTTR. This report describes the design and specification of the surveillance system for the radiation monitoring which consists of radiation monitors, radiation measuring instruments and personal computers in HTTR. The outline of HTTR is also described. (author)

  8. The CERN GSM monitoring system

    CERN Document Server

    Ghabrous, C

    2010-01-01

    This paper presents the way CERN has approached the problem of monitoring its own GSM infrastructure, especially in the Large Hadron Collider (LHC) accelerator tunnel and other underground facilities, where a leaky feeder cable carries mobile phone signals, and where this technology is the only means for inter-personnel communications

  9. Radon generation and transport in and around a gold mine tailings dam in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Speelman, W.J.; Lindsay, R. [Western Cape Univ., Dept. of Physics (South Africa); Newman, R.T. [IThemba LABS, Somerset West (South Africa); Meijer, R.J. de [Nuclear Geophysics Division (NGD), KVI, Rijksuniversiteit Groningen (Netherlands)

    2006-07-01

    Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements were performed at certain points on the mine tailings with a continuous radon monitor; R.A.D.7, and emanation coefficients were measured with electret technology. These parameters have been combined with the activity concentrations to obtain an average radon exhalation rate of about 0.1 Bq.m{sup -2}.s{sup -1} (with an uncertainty of about 20%) from the tailings dam. The purpose of the study is to also review and develop a mathematical model for radon activity concentration predictions in gold mine dumps. (authors)

  10. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  11. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  12. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  13. Determination of radon in the air of housings of the Aguascalientes municipality; Determinacion de radon en el aire en viviendas del municipio de Aguascalientes

    Energy Technology Data Exchange (ETDEWEB)

    Jasso G, M.R.; Lira P, M.G.; Bonilla P, A.; Ruvalcaba S, L.; Gutierrez S, K.M.; Sandoval A, G.E. [Instituto Tecnologico de Aguascalientes, Av. Lopez Mateos 1801, 20256 Aguascalientes (Mexico); Sanchez H, L. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. e-mail: jassogonzalezre@yahoo.com.mx

    2006-07-01

    This study reports the results of the first exploratory sampling of the radon concentration in the air in a group of housings of the Aguascalientes City, Mexico. The municipality of Aguascalientes was divided in 4 sampling areas considering a total of 179 housings. In these housings, the radon concentration in the air was monitored during a period of 10 days. The results obtained in this study indicate that the radon concentration in the air of 45% of the sampling housings overcomes the concentration limit of 250 Bq/m{sup 3} suggested by the EPA. (Author)

  14. Innovative radon detecting technique for locating underground heating areas

    Energy Technology Data Exchange (ETDEWEB)

    Sheng Xue; Jianming Wu; Rao Balusu; Rhys Worrall [CSIRO Exploration & Mining (Australia)

    2003-09-01

    In Australia there is currently no remote sensing technique to locate underground spontaneous combustion of coal remotely from the surface. The main objectives of the project were to investigate and demonstrate a surface-based radon technique developed by Taiyuan University of Technology and used in Chinese coal mines to detect the location of underground spontaneous combustion (sponcom). Radon-222 gas occurs naturally as a decay product of the long-lived uranium-238 that is a common rare element in rock/coal/soil strata. In the event that spontaneous combustion of coal occurs underground, the radon emanation ratio from coal, and its migration through the overlying coal/rock strata increase significantly. The elevated radon concentrations are detected and used to locate the underground area of spontaneous combustion of coal. Field demonstration of the radon technique was carried out in two separate areas at Dartbrook mine to locate the suspected sponcom of coal in these areas. Test results in the LW7 area indicated that there existed four zones of coal heating. Results also indicated that the area of heatings might have been quite extensive prior to the treatments of the sponcom. This implied that the treatments of sponcom in the LW7 goaf were effective. These results are consistent with those based on analysis of gas monitoring data. Test results in the CDH003 area indicated that there existed one zone of coal heating. Results indicated that the heating in this zone was of fairly low intensity. It appears that the identified zone is about 50m off the likely heating location in the area. This discrepancy poses a challenge to the radon technique, however it also provides an opportunity to undertake further study on the radon technique.

  15. Effect of indoor-generated airborne particles on radon progeny dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Trassierra, C. Vargas [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); Stabile, L., E-mail: l.stabile@unicas.it [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); Cardellini, F.; Morawska, L. [National Institute of Ionizing Radiation Metrology (INMRI-ENEA), Rome (Italy); Buonanno, G. [Department of Civil and Mechanical Engineering, University of Cassino and Southern Lazio, Cassino, FR (Italy); International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane (Australia)

    2016-08-15

    Highlights: • Investigation of the interaction between particles and radon progeny dynamics. • Measurements of particles emitted by different indoor sources. • Tests performed in a controlled radon chamber. • Particle size strongly influences the radon progeny dynamics. • Particle surface area concentration is the key parameter of the radon-particle interaction. - Abstract: In order to investigate the interaction between radon progeny and particles, an experimental campaign was carried out in a radon chamber at the Italian National Institute of Ionizing Radiation Metrology, quantifying the amount of attached and unattached radon daughters present in air, as well as the equilibrium factor in the presence of particles generated through indoor sources. A fixed radon concentration was maintained, while particles were generated using incense sticks, mosquito coils and gas combustion. Aerosols were characterized in terms of particle concentrations and size distributions. Simultaneously, radon concentration and attached/unattached potential alpha energy concentration in the air were continuously monitored by two different devices, based on alpha spectroscopy techniques. The presence of particles was found to affect the attached fraction of radon decay products, in such a way that the particles acted as a sink for radionuclides. In terms of sources which emit large particles (e.g. incense, mosquito coils), which greatly increase particle surface area concentrations, the Equilibrium Factor was found to double with respect to the background level before particle generation sessions. On the contrary, the radon decay product dynamics were not influenced by gas combustion processes, mainly due to the small surface area of the particles emitted.

  16. Image detection monitoring system (IDMS) for landslide monitoring

    Science.gov (United States)

    Lollino, Giorgio; Allasia, Paolo; Baldo, Marco; Giordan, Daniele

    2010-05-01

    In the field of topographic displacement monitoring systems, the CNR IRPI of Turin has developed and patented a new instrumentation, named Image Detection For Monitoring System (IDMS). The IDMS is constituted by a digital reflex camera that, according to different needs, can be combined to a long range reflectorless laser distantiometer . The resulting assembly is automatically moved by an high accuracy sophisticated positioning mechanism managed by a low-consumption pc. The principle of operation is based on the analysis of a time series of pictures of an area that, processed using particular algorithms, allow to obtain topographic displacements. If necessary, with the long range laser integration it is also possible to get the displacement values in three-dimensions. The system, initially experimented with the use of a cam, has been improved using a reflex camera, developing a special software that allowed to improve performances and to set algorithms to seek the monitored areas. These implementations, in addition to the freedom from the needs of reflecting targets, increase the system flexibility that can operate in dynamic contexts where the phenomenon morphology can quickly change. With this characteristics , the IDMS can preserve the topographic total station accuracy, but it hasn't the necessity to use expensive reflecting targets, often characterized by the difficulty of their installation and maintenance. These characteristics make the system most flexible allowing to modify the investigated areas without particular logistic difficulties and without further costs.

  17. A Framework for Remote Monitoring System

    Science.gov (United States)

    Crysdian, Cahyo

    2017-04-01

    Remote monitoring system becomes an important facility to support observation activities for various natural disasters. In many incidents of natural disaster such as volcano eruptions, the available monitoring systems installed closely to disaster area were damaged due to extreme condition raised by the event. The temperature of disaster site could suddenly increase to hundred degrees of Celsius, drowned in a water flood or even trapped in a toxic heating gas. Therefore, it is important to have observation facility that is installed far away from disaster area. This research is an exploratory study to develop the framework for remote monitoring system. It includes hardware requirement and algorithm definition that cover system lenses and a set of image processing algorithm. The framework delivers a promising preliminary result towards the effort for remote monitoring system development.

  18. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  19. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  20. Indoor Radon and Its Decay Products: Concentrations, Causes, and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-01-01

    This report is an introduction to the behavior of radon 222 and its decay products in indoor air. This includes review of basic characteristics of radon and its decay products and of features of the indoor environment itself, all of which factors affect behavior in indoor air. The experimental and theoretical evidence on behavior of radon and its decay products is examined, providing a basis for understanding the influence of geological, structural, and meteorological factors on indoor concentrations, as well as the effectiveness of control techniques. We go on to examine three important issues concerning indoor radon. We thus include (1) an appraisal of the concentration distribution in homes, (2) an examination of the utility and limitations of popular monitoring techniques and protocols, and (3) an assessment of the key elements of strategies for controlling radon levels in homes.

  1. Radon assay and radioactivity database in Kamioka

    Science.gov (United States)

    Takeuchi, Yasuo; Tasaka, Shigeki; Nakano, Yuuki

    2017-09-01

    A new cooperative program among underground experiments, theorists, and low-background researchers was started in 2014 in Japan. The purpose of this program is to achieve technical and scientific synergies among underground researchers. In this report, the R&D of radon assay technique as an activity in this program is shown. The current status of the radioactivity database system in Kamioka is also shown.

  2. Indoor radon survey in dwellings of nine cities in the Eastern and the Western provinces of Saudi Arabia.

    Science.gov (United States)

    Abu-Jarad, F; Fazal-ur-Rehman; Al-Jarallah, M I; Al-Shukri, A

    2003-01-01

    The results of a first phase of an indoor radon survey in a total of 1610 dwellings distributed in nine cities of the Eastern and the Western provinces of Saudi Arabia are presented. The objective of this radon survey was to obtain representative indoor radon data for seven cities in the Eastern province. Khafji, Hafr Al-Batin, Abqaiq, Qatif, Al-Ahsa, Dammam and Khobar and to compare this with two cities in the Western province, Madina and Taif. So far, detailed radon data is not available for Saudi Arabia: therefore, this radon survey provides a base line for Saudi Arabia in the Radon World Atlas. On average, 200 indoor radon dosemeters were distributed in each city and placed for a period of one year starting from May 2001 to May 2002. The total number of collected dosemeters was 847. A total of 724 houses and 98 schools were covered in this survey. The results of the survey in the cities showed that the overall minimum, maximum and average radon concentrations were 1, 137 and 22 Bq m(-3), respectively. Geometric mean and geometric standard deviations of the radon distribution were found to be 18 and 1.92, respectively. In one of the dwellings in Qatif city, radon concentration, measured by a passive system and then confirmed by an active system, was found to be 535 +/- 23 and 523 +/- 22 Bq m(-3), respectively. The result of a radon survey in 98 schools showed that the minimum, maximum and average radon concentrations were 1, 70 and 19 Bq m(-3), respectively. The average radon concentration for each city was also determined. The lowest average radon concentration (8 Bq m(-3)) was found in Al-Ahsa while the highest average concentration (40 Bq m(-3)) was found in Khafji.

  3. Residential radon remediation: performance over 17 years.

    Science.gov (United States)

    Harley, Naomi H; Chittaporn, Passaporn; Marsicano, Anthony

    2011-05-01

    An exploratory radon measurement in 1990 identified 190 Bq m(-3) in the basement of a newly built home in Central New Jersey. Subsequently, the owner had a sub-slab remediation system installed in the basement, i.e. PVC duct through the basement floor connecting to an exhaust fan venting to the house roof. Sequential radon measurements began in 1992 using the NYU alpha-track detector. The homeowner wanted to insure the long-term durability of this remedial system. Seventeen years of measurements show the system functioned properly and reduced an established baseline concentration of 370 ± 8, 56 ± 1 and 67 ± 1 Bq m(-3) for the basement, first and second floors, respectively, to an average of 19 ± 4, 13 ± 3 and 10 ± 0.1 Bq m(-3). The last measurement, 2007-2008, with a newer NYU detector measured both (222)Rn (radon) and (220)Rn (thoron). The basement thoron concentration was 1.5 ± 0.9 Bq m(-3) or about 8 % of the (222)Rn value.

  4. A plasma process monitor/control system

    Energy Technology Data Exchange (ETDEWEB)

    Stevenson, J.O.; Ward, P.P.; Smith, M.L. [Sandia National Labs., Albuquerque, NM (United States); Markle, R.J. [Advanced Micro Devices, Inc., Austin, TX (United States)

    1997-08-01

    Sandia National Laboratories has developed a system to monitor plasma processes for control of industrial applications. The system is designed to act as a fully automated, sand-alone process monitor during printed wiring board and semiconductor production runs. The monitor routinely performs data collection, analysis, process identification, and error detection/correction without the need for human intervention. The monitor can also be used in research mode to allow process engineers to gather additional information about plasma processes. The plasma monitor can perform real-time control of support systems known to influence plasma behavior. The monitor can also signal personnel to modify plasma parameters when the system is operating outside of desired specifications and requires human assistance. A notification protocol can be selected for conditions detected in the plasma process. The Plasma Process Monitor/Control System consists of a computer running software developed by Sandia National Laboratories, a commercially available spectrophotometer equipped with a charge-coupled device camera, an input/output device, and a fiber optic cable.

  5. Sleep Monitoring System Using Kinect Sensor

    National Research Council Canada - National Science Library

    Lee, Jaehoon; Hong, Min; Ryu, Sungyong

    2015-01-01

    .... In this paper, we proposed and implemented the sleep monitoring system which can detect the sleep movement and posture during sleep using a Microsoft Kinect v2 sensor without any body attached devices...

  6. Closed circuit TV system monitors welding operations

    Science.gov (United States)

    Gilman, M.

    1967-01-01

    TV camera system that has a special vidicon tube with a gradient density filter is used in remote monitoring of TIG welding of stainless steel. The welding operations involve complex assembly welding tools and skates in areas of limited accessibility.

  7. Radon survey related to construction materials and soils in Zacatecas, Mexico using LR-115

    Energy Technology Data Exchange (ETDEWEB)

    Mireles, F. [Unidad Academica de Estudios Nucleares, Universidad Autonoma de Zacatecas, Cipres 10, Frac. La penuela, Zacatecas, Zac., CP 98068 (Mexico)], E-mail: fmireles@uaz.edu.mx; Garcia, M.L.; Quirino, L.L.; Davila, J.I.; Pinedo, J.L.; Rios, C. [Unidad Academica de Estudios Nucleares, Universidad Autonoma de Zacatecas, Cipres 10, Frac. La penuela, Zacatecas, Zac., CP 98068 (Mexico); Montero, M.E. [Centro de Investigacion en Materiales Avanzados, S.C. Complejo Industrial Chihuahua, Miguel de Cervantes 120, Chihuahua, Chih., CP 31109 (Mexico); Colmenero, L. [Instituto Tecnologico de Chihuahua II, Ave de las Industrias 11101, Chihuahua, Chih. (Mexico); Villalba, L. [Facultad de Ingenieria, Universidad Autonoma de Chihuahua, Circuito No. 1, Nuevo Campus Universitario, Chihuahua, Chih. C.P. 31125 (Mexico)

    2007-09-15

    Indoor radon gas ({sup 222}Rn), present in the air inside buildings, is one of the most important sources of radiation exposure to the population. This gas originates in the {sup 238}U radioactive decay chain, which is contained in rock and solid soil particles. Radon accumulation in confined spaces, inside buildings, depends on several factors such as the type of soils, type of constructions, building materials, and ventilation. The aim of this work is to present indoor and outdoor radon concentrations for 202 dwellings and indoor concentrations for 148 public clinics; and the radon concentrations relate to the type of predominant soils, the construction years; and building materials used in the ceilings, walls and floors, for cities and towns of the 57 municipalities in the State of Zacatecas, Mexico. The {sup 222}Rn concentrations were measured with a passive-type radon monitor, with LR-115 as detector material; and the radon survey was made during four stages of three months each throughout Zacatecas from 2001 to 2002. The indoor and outdoor radon concentration averages in dwellings were 55.6{+-}4.9Bqm{sup -3} and 46.5{+-}5.3Bqm{sup -3}, respectively. The indoor radon concentration average in public clinics was 57.8{+-}5.4Bqm{sup -3}. These values were lower than the US EPA action limit of 148Bqm{sup -3}.

  8. Optimized Temporal Monitors for SystemC

    Science.gov (United States)

    Tabakov, Deian; Rozier, Kristin Y.; Vardi, Moshe Y.

    2012-01-01

    SystemC is a modeling language built as an extension of C++. Its growing popularity and the increasing complexity of designs have motivated research efforts aimed at the verification of SystemC models using assertion-based verification (ABV), where the designer asserts properties that capture the design intent in a formal language such as PSL or SVA. The model then can be verified against the properties using runtime or formal verification techniques. In this paper we focus on automated generation of runtime monitors from temporal properties. Our focus is on minimizing runtime overhead, rather than monitor size or monitor-generation time. We identify four issues in monitor generation: state minimization, alphabet representation, alphabet minimization, and monitor encoding. We conduct extensive experimentation and identify a combination of settings that offers the best performance in terms of runtime overhead.

  9. Class 3 Tracking and Monitoring System Report

    Energy Technology Data Exchange (ETDEWEB)

    Safely, Eugene; Salamy, S. Phillip

    1999-11-29

    The objective of Class 3 tracking system are to assist DOE in tracking and performance and progress of these projects and to capture the technical and financial information collected during the projects' monitoring phase. The captured information was used by DOE project managers and BDM-Oklahoma staff for project monitoring and evaluation, and technology transfer activities. The proposed tracking system used the Class Evaluation Executive Report (CLEVER), a relation database for storing and disseminating class project data; GeoGraphix, a geological and technical analysis and mapping software system; the Tertiary Oil Recovery Information System (TORIS) database; and MS-Project, a project management software system.

  10. Correlating precursory declines in groundwater radon with earthquake magnitude.

    Science.gov (United States)

    Kuo, T

    2014-01-01

    Both studies at the Antung hot spring in eastern Taiwan and at the Paihe spring in southern Taiwan confirm that groundwater radon can be a consistent tracer for strain changes in the crust preceding an earthquake when observed in a low-porosity fractured aquifer surrounded by a ductile formation. Recurrent anomalous declines in groundwater radon were observed at the Antung D1 monitoring well in eastern Taiwan prior to the five earthquakes of magnitude (Mw ): 6.8, 6.1, 5.9, 5.4, and 5.0 that occurred on December 10, 2003; April 1, 2006; April 15, 2006; February 17, 2008; and July 12, 2011, respectively. For earthquakes occurring on the longitudinal valley fault in eastern Taiwan, the observed radon minima decrease as the earthquake magnitude increases. The above correlation has been proven to be useful for early warning local large earthquakes. In southern Taiwan, radon anomalous declines prior to the 2010 Mw 6.3 Jiasian, 2012 Mw 5.9 Wutai, and 2012 ML 5.4 Kaohsiung earthquakes were also recorded at the Paihe spring. For earthquakes occurring on different faults in southern Taiwan, the correlation between the observed radon minima and the earthquake magnitude is not yet possible. © 2013, National Ground Water Association.

  11. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  12. The Italian national survey of indoor radon exposure.

    Science.gov (United States)

    Sciocchetti, G; Scacco, F; Baldassini, P G; Battella, C; Bovi, M; Monte, L

    1985-10-01

    An investigation is being developed by the Comitato Nazionale per la Ricerca e per lo Sviluppo dell'Energia Nucleare e delle Energie Alternative, ENEA, to assess the indoor exposure of the Italian population. The programme, which started in 1982, includes regional and local surveys in all the administrative districts and intensive investigations of factors which influence indoor radon levels. The survey is organized by statistical areas of sampling to obtain representative samples of houses. The definition of the areas takes into account basic parameters e.g. geolithological environments, radon soil gas from underlying soils and rocks, specific activities of local building materials, climatic and seasonal variations, building technology, types of houses and town planning. The collected data may also be used for the compilation of radon risk maps to plan special monitoring and remedial actions if needed. Preliminary results concerning the above items are discussed.

  13. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  14. Study of radon measurement instrumentation in extreme environmental conditions; Estudio de la instrumentacion de medida de radon en condiciones ambientales extremas

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, V.; Baixeras, C.; Amgarou, K.; Font, L.; Vargas, A.; Grossi, C.

    2011-07-01

    Within the framework of the scientific project of the Nuclear Safety Council ''Study of environmental monitoring instrumentation and measurement of radon in extreme environmental conditions' at the Universitat Autonoma de Barcelona has established a partnership with the Universitat Politecnica de Catalunya (UPC) to conduct a study to identify the most appropriate filters to minimize the influence of measurement conditions, particularly with respect to moisture on the response of continuous radon detectors and integrators. (Author)

  15. Monitoring the CMS data acquisition system

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, G [MIT, Cambridge (United States); Behrens, U; Hatton, D [DESY, Hamburg (Germany); Biery, K; Cheung, H [FNAL, Chicago (United States); Branson, J; Coarasa, J A; Dusinberre, E [UCSD, San Diego (United States); Cano, E; Ciganek, M; Cittolin, S; Deldicque, C; Erhan, S; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Laurens, J F; Perez, J A Lopez [CERN, Geneva (Switzerland); Rodrigues, F Fortes, E-mail: Luciano.Orsini@cern.c [CEFET/RJ (Brazil)

    2010-04-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of collections. An implementation following this scheme is deployed as the monitoring infrastructure of the CMS experiment at the Large Hadron Collider. All services in this distributed data acquisition system are providing standard web service interfaces via XML, SOAP and HTTP. Continuing on this path we adopted WS-* standards implementing a monitoring system layered on top of the W3C standards stack. We designed a load-balanced publisher/subscriber system with the ability to include high-speed protocols for efficient data transmission and serving data in multiple data formats.

  16. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...

  17. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...

  18. Monitoring systems for community water supplies

    Science.gov (United States)

    Taylor, R. E.; Brooks, R. R.; Jeffers, E. L.; Linton, A. T.; Poel, G. D.

    1978-01-01

    Water monitoring system includes equipment and techniques for waste water sampling sensors for determining levels of microorganisms, oxygen, chlorine, and many other important parameters. System includes data acquisition and display system that allows computation of water quality information for real time display.

  19. A proactive system for maritime environment monitoring.

    Science.gov (United States)

    Moroni, Davide; Pieri, Gabriele; Tampucci, Marco; Salvetti, Ovidio

    2016-01-30

    The ability to remotely detect and monitor oil spills is becoming increasingly important due to the high demand of oil-based products. Indeed, shipping routes are becoming very crowded and the likelihood of oil slick occurrence is increasing. In this frame, a fully integrated remote sensing system can be a valuable monitoring tool. We propose an integrated and interoperable system able to monitor ship traffic and marine operators, using sensing capabilities from a variety of electronic sensors, along with geo-positioning tools, and through a communication infrastructure. Our system is capable of transferring heterogeneous data, freely and seamlessly, between different elements of the information system (and their users) in a consistent and usable form. The system also integrates a collection of decision support services providing proactive functionalities. Such services demonstrate the potentiality of the system in facilitating dynamic links among different data, models and actors, as indicated by the performed field tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Guidance on Radon Resistant Construction and Radon Mitigation

    Science.gov (United States)

    This Unnumbered Letter regarding radon gas mitigation applies to all housing and community facilities, low-rise buildings and dwellings for the mentioned programs. Its intention is to guide staff to best serve our borrowers and protect their health.

  1. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  2. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  3. Development of a radon standard source

    Science.gov (United States)

    Sakamoto, Shigeyasu; Ishimori, Yuu; Maruo, Yoshihiro

    2005-06-01

    The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].

  4. A large-scale study of a measure against soil gas radon

    NARCIS (Netherlands)

    van der Graaf, E.R.; de Meijer, R.J.

    1999-01-01

    This paper presents the results of a large-scale study (50 single family houses with a crawl space) on the effectiveness of using a foil on the crawl space floor in combination with a Sub-Foil Air Removal (SFAR) system as a measure for reducing indoor radon concentrations. Radon measurements in both

  5. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  6. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, Gary L.; Meikrantz, David H.; Ely, Walter E.; Tuggle, Dale G.; Grafwallner, Ervin G.; Wickham, Keith L.; Maltrud, Herman R.; Baker, John D.

    1992-01-01

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter.

  7. 30 CFR 57.5046 - Protection against radon gas.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection against radon gas. 57.5046 Section... Protection against radon gas. Where radon daughter concentrations exceed 10 WL, respirator protection against radon gas shall be provided in addition to protection against radon daughters. Protection against radon...

  8. Radon risk in the house; Il rischio radon nelle abitazioni

    Energy Technology Data Exchange (ETDEWEB)

    Bressa, G. [Padua Univ., Padua (Italy). Dipt. di Farmacologia e Anestesiologia, Lab. di Tossicologia

    2001-04-01

    Radon was discovered in 1900, but its potential dangerousness for man was fully understood only in 1950. Being a radioactive natural gas - and therefore particularly dangerous - radon results from the long decay chain of radionuclides, such as thorium and radium. Some igneous rocks (granite, tufa and lava) as well as coal are considered to be the main sources of this radionuclide. A number of epidemiologic studies have shown the carcinogenicity of this element, particularly among miners and workers subjected to high level exposure in confined spaces such as basements, garages, cellars, etc. There are, however, some techniques to remove radon in order to reduce exposure to minimum values. [Italian] Il radon fu scoperto nel 1900, ma solo nel 1950 si comprese la sua potenziale pericolosita' per l'uomo. Il radon e' particolarmente pericoloso essendo un gas naturale radioattivo. Esso proviene dalla lunga catena di decadimento di radionuclidi come il torio e di radio. Sorgenti di tale radionuclide sono da considerarsi principalmente alcune rocce ignee (graniti, tufi e lave) e il carbone. Diversi studi epidemiologici hanno evidenziato la cancerogenicita' di tale elemento, specie tra i minatori e soggetti esposti ad alti livelli in ambienti confinati quali scantinati, garage sotterranei, ecc.. Esistono comunque tecniche di intervento per la rimozione del gas radon in modo tale da ridurre l'esposizione a valori minimi.

  9. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  10. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  11. A Physician's Guide to Radon

    Science.gov (United States)

    This booklet has been developed for physicians by the U.S. Environmental Protection Agency in consultation with the American Medical Association (AMA). Its purpose is to enlist physicians in the national effort to inform the American public about radon.

  12. Radon measurements along active faults in the Langadas Basin, northern Greece

    Directory of Open Access Journals (Sweden)

    C. Papastefanou

    2001-01-01

    Full Text Available A network of three radon stations has been established in the Langadas Basin, northern Greece for radon monitoring by various techniques in earthquake prediction studies. Specially made devices with plastic tubes including Alpha Tracketch Detectors (ATD were installed for registering alpha particles from radon and radon decay products exhaled from the ground, every 2 weeks, by using LR-115, type II, non-strippable Kodak films, starting from December 1996. Simultaneous measurements started using Lucas cells alpha spectrometer for instantaneous radon measurements in soil gas, before and after setting ATDs at the radon stations. Continuous monitoring of radon gas exhaling from the ground started from the middle of August 1999 by using silicon diode detectors, which simultaneously register meteorological parameters, such as rainfall, temperature and barometric pressure. The obtained data were studied together with the data of seismic events, such as the magnitude, ML, of earthquakes that occurred at the Langadas Basin during the period of measurements, as registered by the Laboratory of Geophysics, Aristotle University of Thessaloniki, in order to find out any association between them.

  13. Radon measurements in schools: an interim report

    Energy Technology Data Exchange (ETDEWEB)

    1989-03-01

    The report provides school officials, groups such as Parent-Teacher Associations, and other interested person with interim information on how to measure radon in schools and what to do if elevated levels are found. The first sections of the document contain facts about radon and the health risks associated with radon exposure. The next sections summarize what is known about radon in schools and provide guidance for conducting radon measurements. The last sections describe how to interpret the measurement results and suggest techniques that can be used to reduce radon concentrations if elevated levels are found.

  14. Well Monitoring System For EGS

    Energy Technology Data Exchange (ETDEWEB)

    Normann, Randy [Perma Works LLC, Pattonville, TX (United States); Glowka, Dave [Perma Works LLC, Pattonville, TX (United States); Normann, Charles [Perma Works LLC, Pattonville, TX (United States); Parker, James [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Josip [Electrochemical Systems Inc, Knoxville, TN (United States); Dustan, Don [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Mario [Electrochemical Systems Inc, Knoxville, TN (United States); Sariri, Kouros [Frequency Management Int. Inc., Huntington Beach, CA (United States); Beal, Craig [MajiQ Technologies Inc., Somerville, MA (United States)

    2017-02-26

    This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

  15. United role of radon decay products and nano-aerosols in radon dosimetry

    Science.gov (United States)

    Smerajec, M.; Vaupotič, J.

    2012-04-01

    The major part of human exposure to natural radiation originates from inhalation of radon (Rn) and radon short-lived decay products (RnDP: 218Po, 214Pb, 214Bi and 214Po). RnDP are formed as a result of α-transformation of radon. In the beginning they are positive ions which neutralize and form clusters with air molecules, and later partly attach to background aerosol particles in indoor air. Eventually, they appear as radioactive nano-aerosols with a bimodal size distribution in ranges of 1-10 nm (unattached RnDP) and of 200-800 nm (attached RnDP). When inhaled, they are deposited in the respiratory tract. Deposition is more efficient for smaller particles. Therefore, the fraction (fun) of the unattached RnDP, which appears to be influenced by the number concentration and size distribution of general (background) aerosols in the ambient air, has a crucial role in radon dosimetry. Radon, radon decay products and general aerosols have been monitored simultaneously in the kitchen of a typical rural house under real living conditions, also comprising four human activities generating particular matter: cooking and baking, as two typical activities in kitchen, and cigarette smoking and candle burning. In periods without any human activity, the total number concentration of general aerosol ranged from 1000 to 3000 cm-3,with the geometric mean of particle diameter in the range of 60-68 nm and with 0.1-1 % of particles smaller than 10 nm. Preparation of coffee changed the concentration to 193,000 cm-3, the geometric mean of diameter to 20 nm and fraction of particles smaller than 10 nm to 11 %. The respective changes were for baking cake: 503,000 cm-3, 17 nm and 19 %, for smoking:423,000 cm-3, 83 nm and 0.4 %, and forcandle burning: 945,000 cm-3, 8 nm and 85 %. While, as expected, a reduction of fun was observed during cooking, baking and smoking, when larger particles were emitted, fun did not increase during candle burning with mostly particles smaller than 10 nm

  16. Decision support system for structure synthesis of monitoring systems

    Directory of Open Access Journals (Sweden)

    Skatkov A. V.

    2008-04-01

    Full Text Available The paper is concerned with a structure synthesis of monitoring systems. In the article a decision support system for such synthesis was proposed and described. In the first phase of the process, the proposed classification of monitoring systems is used. Then adaptive algorithms, simulation and analytic modeling are used. The results of studies carried out by means of the proposed program are represented. The topicality of proposed approach was demonstrated. It should be mentioned, that algorithms were thoroughly described, the computing experiments were carried out. The authors believe that the proposed decision support system has many advantages and, consequently, is very useful in structure synthesis of monitoring systems.

  17. Indoor radon survey in dwellings of nine cities in the eastern and western provinces of Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Fazal-ur-Rehman; Al-Jarallah, M.I.; Al-Shukri, A

    2003-07-01

    The results of a first phase of an indoor survey in a total of 1610 dwellings distributed in nine cities of the Eastern and the Western provinces of Saudi Arabia are presented. The objective of this radon survey was to obtain representative indoor radon data for seven cities in the Eastern province, Khafji, Hafr Al-Batin, Abqaiq, Qatif, Al-Ahsa, Dammam and Khobar and to compare this with two cities in the Western province, Madina and Taif. So far, detailed radon data is not available for Saudi Arabia; therefore, this radon survey provides a base line for Saudi Arabia in the Radon World Atlas. On average, 200 indoor radon dosemeters were distributed in each city and placed for a period of one year starting from May 2001 to May 2002. The total number of collected dosemeters was 847. A total of 724 houses and 98 schools were covered in this survey. The results of the survey in the cities showed that the overall minimum, maximum and average radon concentrations were 1, 137 and 22 Bq m {sup -3}, respectively. Geometric mean and geometric standard deviations of the radon distribution were found to be 18 and 1.92, respectively. In one of the dwellings in Qatif city, radon concentration, measured by a passive system and then confirmed by an active system, was found to be 535 {+-} 23 and 523 {+-} 22 Bq m {sup -3}, respectively. The result of a radon survey in 98 schools showed that the minimum, maximum and average radon concentrations were 1, 70 and 19 Bq m{sup -3}, respectively. The average radon concentration for each city was also determined. The lowest average radon concentration (8 Bq m{sup -3}) was found in Al-Ahsa while the highest average concentration (40 Bq m {sup -3}) was found in Khafji. (author)

  18. National Antimicrobial Resistance Monitoring System (NARMS) Program

    Science.gov (United States)

    The National Antimicrobial Resistance Monitoring System (NARMS) – Enteric Bacteria is a national public health surveillance system in the United States that tracks changes in the susceptibility of certain enteric bacteria to antimicrobial agents of human and veterinary medical importance. The NARMS ...

  19. Phytosanitary monitoring and surveillance system for integrated ...

    African Journals Online (AJOL)

    This paper discusses a phytosanitary monitoring and surveillance system as a component of an integrated pest management strategy. The main stages of the system are alert, census and action. The education and training of farmers, plantation personnel, and extension workers to recognise the main pests, early damage ...

  20. instrumentation for power system disturbance monitoring, data ...

    African Journals Online (AJOL)

    Dr Obe

    1996-09-01

    Sep 1, 1996 ... acquisition and control in Nigerian Electric Power System; National Electric Power Authority. (NEPA) is presented. The need for ... feature of an adequate monitoring, data acquisition and control system is discussed. The state of the ... resulting data used to switch on adequate V. AR support. In this paper ...

  1. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  2. Association of School District Policies for Radon Testing and Radon-Resistant New Construction Practices with Indoor Radon Zones.

    Science.gov (United States)

    Foster, Stephanie; Everett Jones, Sherry

    2016-12-13

    Radon is a naturally occurring, colorless, odorless, and tasteless radioactive gas. Without testing, its presence is unknown. Using nationally representative data from the 2012 School Health Policies and Practices Study, we examined whether the prevalence of school district policies for radon testing and for radon-resistant new construction practices varied by district location in relation to the U.S. Environmental Protection Agency Map of Radon Zones. Among school districts located in counties with high predicted average indoor radon, 42.4% had policies for radon testing and 37.5% had policies for radon-resistant new construction practices. These findings suggest a critical need for improved awareness among policy makers regarding potential radon exposure for both students and school staff.

  3. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  4. Radon legislation and national guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Aakerblom, G

    1999-07-01

    The International Commission on Radiological Protection (ICRP) and The Council of the European Union have recommended the Member States to take action against radon in homes and at workplaces. Within the EU project European Research into Radon in Construction Concerted Action, ERRICCA, the Topic Group on Legal and Building Code Impact was designated to study the current radon legislation and give advice regarding future enactment of laws and recommendations. On behalf of the Group, a questionnaire on radon legislation was sent out to nearly all European states and a selection of non-European states. Questions were asked regarding reference levels for dwellings, workplaces and drinking water, and about regulations or recommendations for building materials and city planning. All 15 EU Member States, 17 non-EU European countries and 10 non-European countries responded to the questionnaire. Their answers are considered current as of the end of 1998. Most European States and many non-European countries have recommended reference levels for dwellings and workplaces, and some have guidelines for measures against radon incorporated in their building codes and guidelines for construction techniques. However, only a few countries have enforced reference levels or regulations for planning and construction. The reference levels for indoor radon concentration in existing and new dwellings or workplaces are within the range 150-1000 Bq/m{sup 3}. Sweden is the only country (Out of 15 EU member states) which has enforced limits for existing dwellings. Sweden and the UK have both enforced levels for new dwellings. 7 non-European countries (Out of 17 responding countries) have enforced levels for existing dwellings and 9 have them for new dwellings. At the end of 1998, only Finland, Sweden, the Czech Republic, Romania, Russia and the Slovak Republic had limits for radon in water, although 8 countries were planning to introduce such limits. The present limits are within the range for

  5. Effect of water vapour condensation on the radon content in subsurface air in a hypogeal inactive-volcanic environment in Galdar cave, Spain

    Science.gov (United States)

    Fernandez-Cortes, A.; Benavente, D.; Cuezva, S.; Cañaveras, J. C.; Alvarez-Gallego, M.; Garcia-Anton, E.; Soler, V.; Sanchez-Moral, S.

    2013-08-01

    Fluctuations of trace gas activity as a response to variations in weather and microclimate conditions were monitored over a year in a shallow volcanic cave (Painted Cave, Galdar, Canary Islands, Spain). 222Rn concentration was used due to its greater sensitivity to hygrothermal variations than CO2 concentration. Radon concentration in the cave increases as effective vapour condensation within the porous system of the rock surfaces inside the cave increases due to humidity levels of more than 70%. Condensed water content in pores was assessed and linked to a reduction in the direct passage of trace gases. Fluctuations in radon activity as a response to variations in weather and microclimate conditions were statistically identified by clustering entropy changes on the radon signal and parameterised to predict radon concentration anomalies. This raises important implications for other research fields, including the surveillance of shallow volcanic and seismic activity, preventive conservation of cultural heritage in indoor spaces, indoor air quality control and studies to improve understanding of the role of subterranean terrestrial ecosystems as reservoirs and/or temporary sources of trace gases.

  6. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  7. Association of School District Policies for Radon Testing and Radon-Resistant New Construction Practices with Indoor Radon Zones

    OpenAIRE

    Stephanie Foster; Sherry Everett Jones

    2016-01-01

    Radon is a naturally occurring, colorless, odorless, and tasteless radioactive gas. Without testing, its presence is unknown. Using nationally representative data from the 2012 School Health Policies and Practices Study, we examined whether the prevalence of school district policies for radon testing and for radon-resistant new construction practices varied by district location in relation to the U.S. Environmental Protection Agency Map of Radon Zones. Among school districts located in counti...

  8. Smart Sensor Network System For Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Javed Ali Baloch

    2012-07-01

    Full Text Available SSN (Smart Sensor Network systems could be used to monitor buildings with modern infrastructure, plant sites with chemical pollution, horticulture, natural habitat, wastewater management and modern transport system. To sense attributes of phenomena and make decisions on the basis of the sensed value is the primary goal of such systems. In this paper a Smart Spatially aware sensor system is presented. A smart system, which could continuously monitor the network to observe the functionality and trigger, alerts to the base station if a change in the system occurs and provide feedback periodically, on demand or even continuously depending on the nature of the application. The results of the simulation trials presented in this paper exhibit the performance of a Smart Spatially Aware Sensor Networks.

  9. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  10. Execution monitoring for a mobile robot system

    Science.gov (United States)

    Miller, David P.

    1990-01-01

    Due to sensor errors, uncertainty, incomplete knowledge, and a dynamic world, robot plans will not always be executed exactly as planned. This paper describes an implemented robot planning system that enhances the traditional sense-think-act cycle in ways that allow the robot system monitor its behavior and react in emergencies in real-time. A proposal on how robot systems can completely break away from the traditional three-step cycle is also made.

  11. Trends in monitoring of waste water systems.

    Science.gov (United States)

    Lynggaard-Jensen, A

    1999-11-15

    A review of the trends in monitoring of waste water systems is given - with the focus on the use of sensors for on-line real-time monitoring and control. The paper formed a basis for discussion at the workshop on Methodologies for Wastewater Quality Monitoring, Nimes, 29-30 October 1998, organised by the European Commission and Ecoles des Mines d'Alès. The basic structure of the typical organisation of monitoring and control based on sensors and the handling of the sensor data are discussed and the different types of sensors are classified according to the method used for their introduction into the structure. Existing and new sensor technologies are briefly described, and the possibilities of how standardisation of on-line in-situ sensors can encourage further developments and use of sensors are presented.

  12. The use of volunteer radon measurements for radon mapping purposes: an examination of sampling bias issues.

    Science.gov (United States)

    Burke, Orlaith; Murphy, Patrick

    2011-09-01

    National and regional radon surveys are used in many nations to produce maps detailing the spatial variation of indoor radon concentrations. National surveys which are designed to be representative use either a geographically-weighted or a population-weighted sampling scheme. Additionally, many countries collect a large number of data on indoor radon concentrations from volunteers who have chosen to have the indoor radon concentration measured in their own dwellings. This work examines the representativeness of volunteer-based samples in radon measurement and explores the effect of potential volunteer bias on radon mapping results. We also investigate the influence that media attention has on volunteer sampling of indoor radon concentrations. The result of our work indicates that volunteer measurements are biased due to over-sampling of high radon areas. Consequently such volunteer radon measurements should not be used for radon mapping purposes.

  13. Indoor radon, geogenic radon surrogates and geology - Investigations on their correlation.

    Science.gov (United States)

    Friedmann, H; Baumgartner, A; Bernreiter, M; Gräser, J; Gruber, V; Kabrt, F; Kaineder, H; Maringer, F J; Ringer, W; Seidel, C; Wurm, G

    2017-01-01

    The indoor radon concentration was measured in most houses in a couple of municipalities in Austria. At the same time the activity concentration of radium in soil, the soil gas radon concentration, the permeability of the ground and the ambient dose equivalent rate were also measured and the geological situations (geological units) were recorded too. From the indoor radon concentration and different house and living parameters a radon potential (Austrian radon potential) was derived which should represent the radon concentration in a standard room. Another radon potential (Neznal radon potential) was calculated from the soil gas radon concentration and the permeability. The aim of the investigation was to correlate all the different variables and to test if the use of surrogate data (e.g. geological information, ambient dose equivalent rate, etc.) can be used to judge the radon risk for an area without performing numerous indoor measurements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Remote System of Temperature Monitoring and Control

    Directory of Open Access Journals (Sweden)

    Vítor Carvalho

    2008-11-01

    Full Text Available This paper presents a system capable of monitoring and control remotely the temperature of a physical space. This work was part of a final year graduation of the Industrial Informatics Course at the Polytechnic Institute of Cávado and Ave. It was developed by an undergraduate student using a LabVIEW custom application with a methodology of on-off control. The local user can use a touch screen display to configure the system setpoint temperature and for overall monitoring. For remote access it can be used any device supporting LabVIEW environment.

  15. Design of Wind Turbine Vibration Monitoring System

    Directory of Open Access Journals (Sweden)

    Shoubin Wang

    2013-04-01

    Full Text Available In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed. In this paper, it analyses the enlargement of all the parts of the structure and the working mechanism, the research method of wind turbine operation vibration is introduced, with the focus being the use of the sensor principle. Finally the hardware design and software of this system is introduced and the main function of this system is described, which realizes condition monitoring of the work state of wind turbines.

  16. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  17. Integrated monitoring and surveillance system for SNM.

    Energy Technology Data Exchange (ETDEWEB)

    Aumeier, S.; Brush, B.; Ewing, T.; Gross, K.; Kotter, D.; Laurin-Kovitz, K.; Walters, G.; Wegerich, S.

    1999-08-04

    Complex special nuclear material (SNM) storage systems can benefit from automated monitoring and data integration systems that maximize safety and security and optimize system maintainability. Current methods of verification, which rely on physical access, are costly and labor intensive. A prototype data analysis. system for nuclear material monitoring is being developed through a joint effort by Argonne National Laboratory (ANL) and Lockheed Martin Idaho Technologies Company (LMITCO). The system synthesizes information from various sources and applies advanced data analysis to predict sensor faults and detect material instabilities and security/safeguards problems. The system makes use of Argonne's Multivariate State Estimation Technique, or MSET, to provide an early warning system for the performance of sensors and processes, The system is being implemented and tested at the Safeguard Technology Evaluation Laboratory (STEL) at ANL-W. The STEL was installed at a Fuel Manufacturing Facility (FMF) special nuclear materials vault at ANL-W in 1997 as part of a DOE Plutonium Focus Area Project. The STEL provides the infrastructure for the demonstration and integration of technologies for monitoring plutonium-bearing materials in various storage configurations. Real sensors located within the STEL are being used to ''calibrate'' and validate. software while simulated sensors are used to mockup larger-scale problems. Preliminary system design and testing results are discussed.

  18. Study of radon dispersion in typical dwelling using CFD modeling combined with passive-active measurements

    Science.gov (United States)

    Rabi, R.; Oufni, L.

    2017-10-01

    Inhalation of radon (222Rn) and its decay products are a major source of natural radiation exposure. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Indoor air conditions and ventilation systems strongly influence the indoor radon concentration. This study focuses on investigating both numerically and experimentally the influence of environmental conditions on the indoor radon concentration and spatial distribution. The numerical results showed that ventilation rate, temperature and humidity have significant impacts on both radon content and distribution. The variations of radon concentration with the ventilation, temperature and relative humidity are discussed. The measurement results show the diurnal variations of the indoor radon concentration are found to exhibit a positive correlation with relative humidity and negatively correlate with the air temperature. The analytic solution is used to validate the numeric results. The comparison amongst analytical, numerical and measurement results shows close agreement.

  19. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  20. Wireless remote monitoring system for sleep apnea

    Science.gov (United States)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2011-04-01

    Sleep plays the important role of rejuvenating the body, especially the central nervous system. However, more than thirty million people suffer from sleep disorders and sleep deprivation. That can cause serious health consequences by increasing the risk of hypertension, diabetes, heart attack and so on. Apart from the physical health risk, sleep disorders can lead to social problems when sleep disorders are not diagnosed and treated. Currently, sleep disorders are diagnosed through sleep study in a sleep laboratory overnight. This involves large expenses in addition to the inconvenience of overnight hospitalization and disruption of daily life activities. Although some systems provide home based diagnosis, most of systems record the sleep data in a memory card, the patient has to face the inconvenience of sending the memory card to a doctor for diagnosis. To solve the problem, we propose a wireless sensor system for sleep apnea, which enables remote monitoring while the patient is at home. The system has 5 channels to measure ECG, Nasal airflow, body position, abdominal/chest efforts and oxygen saturation. A wireless transmitter unit transmits signals with Zigbee and a receiver unit which has two RF modules, Zigbee and Wi-Fi, receives signals from the transmitter unit and retransmits signals to the remote monitoring system with Zigbee and Wi-Fi, respectively. By using both Zigbee and Wi-Fi, the wireless sensor system can achieve a low power consumption and wide range coverage. The system's features are presented, as well as continuous monitoring results of vital signals.

  1. Recent topics on radon. Radiation dose estimation using radon

    Energy Technology Data Exchange (ETDEWEB)

    Shimo, Michikuni [National Inst. of Radiological Sciences, Chiba (Japan)

    1998-05-01

    Today, as exposure of radon was collected a large interest in resident environment, it was brought by a fact that yearly radiation dose of radon was determined 1.0 mSv in the report of UN science committee in 1982. Since then, as this value was received generally and widely, this value was found some differences due to thereafter UN science committee reports and to some countings. As not only concentration of radon but also some factors relate to its cause, it is important to know its cause and variation width. In this paper, by using the newest data in Japan on radon concentration, balance factor, presence time, respiration volume, and so forth as much as possible, an effective radiation dose of an adult per year was estimated. As a result, it was found to be about 0.45 mSv, which was more than a half less than the value of the UN science committee and so on. And, this was nearly equal to that of workers at 3 prefectures of that Tokai District and counted by using radon concentration, respiration volume and presence coefficient for variants. On counting the whole variation width under considering width of each coefficient, it can be estimated to be ranged from -70 to +80%. (G.K.)

  2. Reducing Radon in Schools: A Team Approach.

    Science.gov (United States)

    Ligman, Bryan K.; Fisher, Eugene J.

    This document presents the process of radon diagnostics and mitigation in schools to help educators determine the best way to reduce elevated radon levels found in a school. The guidebook is designed to guide school leaders through the process of measuring radon levels, selecting the best mitigation strategy, and directing the efforts of a…

  3. Modelling of radon transport in porous media

    NARCIS (Netherlands)

    van der Graaf, E.R.; de Meijer, R.J.; Katase, A; Shimo, M

    1998-01-01

    This paper aims to describe the state of the art of modelling radon transport in soil on basis of multiphase radon transport equations. Emphasis is given to methods to obtain a consistent set of input parameters needed For such models. Model-measurement comparisons with the KVI radon transport

  4. Characterization of blowholes as radon and thoron sources in the volcanic region of La Garrotxa, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, V., E-mail: victoria.moreno@uab.ca [Grup de Fisica de les Radiacions, Departament de Fisica, Edifici Cc, Universitat Autonoma de Barcelona, 08193 Bellaterra, Barcelona (Spain); Bach, J. [Unitat de Geodinamica Externa i d' Hidrogeologia, Departament de Geologia, Edifici Cs, Universitat Autonoma de Barcelona, 08193 Bellaterra, Barcelona (Spain); Baixeras, C.; Font, Ll. [Grup de Fisica de les Radiacions, Departament de Fisica, Edifici Cc, Universitat Autonoma de Barcelona, 08193 Bellaterra, Barcelona (Spain)

    2009-10-15

    In the volcanic region of La Garrotxa there are natural holes in the soil from which a flow of air can reach the outdoor/indoor environment. In a previous study, these holes (called blowholes) have been found to have a big influence on indoor radon levels in a couple of houses. This finding triggered the interest to characterize these blowholes as radon/thoron sources. In this work, a total of 26 holes have been identified and characterized by geological field observations and by measuring their dimensions, air speed, temperature, humidity, and radon and thoron concentrations. Radon has been measured with passive (Makrofol) and active detectors (monitors PRASSI and RAD 7, being the latter used also to measure thoron). One of the indoor blowholes has been studied in detail and important temporal variations have been found, showing that radon levels are clearly correlated with the soil-outdoor temperature difference. There is not a significant radiological risk for the inhabitants and workers of the studied homes and workplaces with indoor blowholes. However, taking into account that in warm seasons buildings with blowholes in pyroclastic materials from volcanoes or in volcanic scoria under a compact lava flow may have high indoor radon levels (up to 1.5 kBq m{sup -3}) we conclude that volcanic regions with similar geological features and with presence of blowholes should be considered as areas with a potential radon/thoron radiological risk.

  5. Web Based Room Monitoring System Using Webcam

    Directory of Open Access Journals (Sweden)

    Tole Sutikno

    2008-04-01

    Full Text Available A security has become very important along with the increasing number of crime cases. If some security system fails, there is a need for a mechanism that capable in recording the criminal act. Therefore, it can be used for investigation purpose of the authorities. The objective of this research is to develop a security system using video streaming that able to monitor in real-time manner, display movies in a browser, and record a video as triggered by a sensor. This monitoring system comprises of two security level camera as a video recorder of special events based on infrared sensor that is connected to a microcontroller via serial communication and camera as a real-time room monitor. The hardware system consists of infrared sensor circuit to detect special events that is serially communicated to an AT89S51 microcontroller that controls the system to perform recording process, and the software system consists of a server that displaying video streaming in a webpage and a video recorder. The software for video recording and server camera uses Visual Basic 6.0 and for video streaming uses PHP 5.1.6. As the result, the system can be used to record special events that it is wanted, and can displayed video streaming in a webpage using LAN infrastructure.

  6. Microsensor Technologies for Plant Growth System Monitoring

    Science.gov (United States)

    Kim, Chang-Soo

    2004-01-01

    This document covered the following: a) demonstration of feasibility of microsensor for tube and particulate growth systems; b) Dissolved oxygen; c)Wetness; d) Flexible microfluidic substrate with microfluidic channels and microsensor arrays; e)Dynamic root zone control/monitoring in microgravity; f)Rapid prototyping of phytoremediation; and g) A new tool for root physiology and pathology.

  7. A hand-hygiene behaviour monitoring system

    NARCIS (Netherlands)

    Van Schie, M.; Wiesman, R.F.F.

    2008-01-01

    The invention relates to a hand-hygiene behaviour monitoring system, comprising: means for detecting the occurrence of an event specified in a hand-hygiene rule, wherein the event involves a person; means for updating behaviour data that is related to acts according to the hand-hygiene rule, wherein

  8. Mobile Patient Monitoring: The Mobihealth System

    NARCIS (Netherlands)

    van Halteren, Aart; Bults, Richard G.A.; Wac, K.E.; Konstantas, D.; Widya, I.A.; Dokovski, N.T.; Koprinkov, G.T.; Jones, Valerie M.; Herzog, Rainer

    2004-01-01

    The forthcoming wide availability of high bandwidth public wireless networks will give rise to new mobile healthcare services. To this end, the MobiHealth project has developed and trialed a highly customisable vital signs monitoring system based on a body area network (BAN) and a mobile-health

  9. Wireless battery management control and monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Zumstein, James M.; Chang, John T.; Farmer, Joseph C.; Kovotsky, Jack; Lavietes, Anthony; Trebes, James Edward

    2018-01-16

    A battery management system using a sensor inside of the battery that sensor enables monitoring and detection of various events in the battery and transmission of a signal from the sensor through the battery casing to a control and data acquisition module by wireless transmission. The detection of threshold events in the battery enables remedial action to be taken to avoid catastrophic events.

  10. Multipurpose ROV system for underwater monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Graczyk, T. [Technical Univ. of Szczecin (Poland)

    1995-12-31

    The paper presents achievements of the Underwater Team at the Faculty of Maritime Technology of the Szczecin Technical University in the field of designing the equipment destined for the underwater monitoring. The multipurpose remotely operated vehicle system is described. Technical specification, some laboratory tank test results, research techniques, operational range, experience and development trends have been discussed.

  11. Beam Loss Monitoring System for the LHC

    CERN Document Server

    Holzer, E B; Effinger, E; Emery, J; Ferioli, G; González, J L; Gschwendtner, E; Guaglio, G; Hodgson, M; Kramer, Daniel; Leitner, R; Ponce, L; Prieto, V; Stockner, M; Zamantzas, C

    2005-01-01

    One of the most critical elements for the protection of CERN's Large Hadron Collider (LHC) is its beam loss monitoring (BLM) system. It must prevent the superconducting magnets from quenching and protect the machine components from damages, as a result of critical beam losses. By measuring the loss pattern, the BLM system helps to identify the loss mechanism. Special monitors will be used for the setup and control of the collimators. The specification for the BLM system includes a very high reliability (tolerable failure rate of 10.-7 per hour) and a high dynamic range of 10.8 (10.13 at certain locations) of the particle fluencies to be measured. In addition, a wide range of integration times (40 micro/s to 84s) and a fast (one turn) trigger generation for the dump signal are required. This paper describes the complete design of the BLM system, including the monitor types (ionization chambers and secondary emission monitors), the design of the analogue and digital readout electronics as well as the data links...

  12. A monitoring system for gypsy moth management

    Science.gov (United States)

    F. William Ravlin; S. J. Fleischer; M. R. Carter; E. A. Roberts; M. L. McManus

    1991-01-01

    Within the last ten years considerable research has been directed toward the development of a gypsy moth monitoring system for project planning at a regional level and for making control decisions at a local level. Pheromones and pheromone-baited traps have been developed and widely used and several egg mass sampling techniques have also been developed. Recently these...

  13. REAL TIME WIRELESS AIR POLLUTION MONITORING SYSTEM

    Directory of Open Access Journals (Sweden)

    Raja Vara Prasad Y

    2011-06-01

    Full Text Available Air pollution has significant influence on the concentration of constituents in the atmosphere leading to effects like global warming and acid rains. To avoid such adverse imbalances in the nature, an air pollution monitoring system is utmost important. This paper attempts to develop an effective solution for pollution monitoring using wireless sensor networks (WSN on a real time basis namely real time wireless air pollution monitoring system. Commercially available discrete gas sensors for sensing concentration of gases like CO2, NO2, CO and O2 are calibrated using appropriate calibration technologies. These pre-calibrated gas sensors are then integrated with the wireless sensor motes for field deployment at the campus and the Hyderabad city using multi hop data aggregation algorithm. A light weight middleware and a web interface to view the live pollution data in the form of numbers and charts from the test beds was developed and made available from anywhere on the internet. Other parameters like temperature and humidity were also sensed along with gas concentrations to enable data analysis through data fusion techniques. Experimentation carried out using the developed wireless air pollution monitoring system under different physical conditions show that the system collects reliable source of real time fine-grain pollution data.

  14. System specification for the integrated monitoring and surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ``Integrated Monitoring and Surveillance System`` is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides.

  15. Factors influencing upstairs and downstairs radon levels in two-storey dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Denman, A.R.; Groves-Kirkby, C.J.; Groves-Kirkby, N.P. [Northampton General Hospital, Medical Physics Dept. (United Kingdom); Crockett, R.G.M.; Phillips, P.S.; Woolridge, A.C. [Northampton Univ., School of Applied Sciences (United Kingdom); Woolridge, A.C. [Northampton Univ., School of Health (United Kingdom)

    2006-07-01

    Environmental radon exposure of residents of two-storey domestic premises is generally estimated on the basis of the measured radon concentrations in, and the relative occupancies of, the principal living-room and bed-room, assuming 45% and 55% occupancy of these two locations respectively. In practice, however, significant case-to-case variability exists, both in the relative periods that individuals spend in the upstairs and downstairs rooms of storey homes, and in the relative radon levels in these two areas. Moreover, while it is assumed that radon levels in upper storeys of multi-storey homes will be intrinsically lower than at ground level, this is not always the case, since radon exhalation from the materials from which the house is constructed may contribute significantly to indoor levels. While studies on radon level variability in the individual units in apartment blocks have been reported, the situation in two-storey low-rise dwellings appears not to have been considered. To investigate this, detailed extended measurements of radon concentrations were made in a set of thirty-four homes situated in areas of Northamptonshire known to exhibit high radon levels and declared a radon Affected Area by the United Kingdom (UK) National Radiological Protection Board (NRPB) in 1992. All homes were of typical UK construction of brick/block/stone walls under a pitched tile/slate roof. Approximately 50% of the sample were detached houses, the remainder being semidetached (duplex) or terraced (row-house). Around 25% of the sample possessed cellars, while 12% were single-storey dwellings. In two-storey homes, all monitored bedrooms were on the upper floor. Distribution of the ratios of bedroom/living-room radon levels in individual properties was left-skewed (mean 0.67, median 0.73, range 0.05 to 1.05). The mean is consistent with the outcome of early NRPB studies in England, while the variability depends principally on the characteristics of the property, and not on

  16. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Cortes-Gonzalez, Arely; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two photomultiplier in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator based readout system. Combined information from all systems allows to monitor and equalise the calorimeter r...

  17. Advanced Virus Monitoring and Analysis System

    OpenAIRE

    Fauzi Adi Rafrastara; Faizal M. A.

    2011-01-01

    This research proposed an architecture and a system which able to monitor the virus behavior and classify them as a traditional or polymorphic virus. Preliminary research was conducted to get the current virus behavior and to find the certain parameters which usually used by virus to attack the computer target. Finally, “test bed environment” is used to test our system by releasing the virus in a real environment, and try to capture their behavior, and followed by generating the conclusion th...

  18. Development of high sensitive radon detector with electrostatic collection

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Machiko [Tokai Univ., Hiratsuka, Kanagawa (Japan). Faculty of Science; Tasaka, Shigeki; Hori, Hidemitsu; Okumura, Kimihiro; Kajita, Takaaki; Takeuchi, Yasuo

    1997-10-01

    One of the main purposes of Super-Kamiokande is the observation of solar neutrinos. The radon concentration in the detector water should be less than about 5 mBq/m{sup 3}, because low energy background events in this experiment are dominated by radon daughters. We developed a high sensitive radon detector with an electrostatic collection method and a PIN photodiode to measure the energy of {alpha} particles from the daughter nuclei of {sup 222}Rn. We constructed a calibration system to study high voltage dependence and absolute humidity dependence of the detector. As a result, the absolute humidity dependence was clearly observed at the region less than 1.6 g/m{sup 3}. The calibration factor at 0.08 g/m{sup 3} was 1.8{+-}0.1 (count/d)/(mBq/m{sup 3}). The detection limit was 13 mBq/m{sup 3} by the Curie`s method. (author)

  19. Distributed Monitoring System Based on ICINGA

    CERN Document Server

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure: it comprises more than 2000 servers and embedded systems and more than 200 network devices. Many of these equipments are critical in order to run the experiment, and it is important to have a monitoring solution performant enough so that the experts can diagnose and act quickly. While our previous system was based on a central Nagios server, our current system uses a distributed Icinga infrastructure. The LHCb installation schema will be presented here, as well some performance comparisons and custom tools.

  20. Weight monitoring system for newborn incubator application

    Science.gov (United States)

    Widianto, Arif; Nurfitri, Intan; Mahatidana, Pradipta; Abuzairi, Tomy; Poespawati, N. R.; Purnamaningsih., Retno W.

    2018-02-01

    We proposed weight monitoring system using load cell sensor for newborn incubator application. The weight sensing system consists of a load cell, conditioning signal circuit, and microcontroller Arduino Uno R3. The performance of the sensor was investigated by using the various weight from 0 up to 3000 g. Experiment results showed that this system has a small error of 4.313% and 12.5 g of threshold and resolution value. Compared to the typical baby scale available in local market, the proposed system has a lower error value and hysteresis.

  1. A Radon Progeny Deposition Model

    Science.gov (United States)

    Guiseppe, V. E.; Elliott, S. R.; Hime, A.; Rielage, K.; Westerdale, S.

    2011-04-01

    The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly 222Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of 210Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

  2. Infrared system for monitoring movement of objects

    Science.gov (United States)

    Valentine, Kenneth H.; Falter, Diedre D.; Falter, Kelly G.

    1991-01-01

    A system for monitoring moving objects, such as the flight of honeybees and other insects, using a pulsed laser light source. This system has a self-powered micro-miniaturized transmitting unit powered, in the preferred embodiment, with an array solar cells. This transmitting unit is attached to the object to be monitored. These solar cells provide current to a storage energy capacitor to produce, for example, five volts for the operation of the transmitter. In the simplest embodiment, the voltage on the capacitor operates a pulse generator to provide a pulsed energizing signal to one or more very small laser diodes. The pulsed light is then received at a receiving base station using substantially standard means which converts the light to an electrical signal for processing in a microprocessor to create the information as to the movement of the object. In the case of a unit for monitoring honeybees and other insects, the transmitting unit weighs less than 50 mg, and has a size no larger than 1.times.3.times.5 millimeters. Also, the preferred embodiment provides for the coding of the light to uniquely identify the particular transmitting unit that is being monitored. A "wake-up" circuit is provided in the preferred embodiment whereby there is no transmission until the voltage on the capacitor has exceeded a pre-set threshold. Various other uses of the motion-detection system are described.

  3. Networked Biomedical System for Ubiquitous Health Monitoring

    Directory of Open Access Journals (Sweden)

    Arjan Durresi

    2008-01-01

    Full Text Available We propose a distributed system that enables global and ubiquitous health monitoring of patients. The biomedical data will be collected by wearable health diagnostic devices, which will include various types of sensors and will be transmitted towards the corresponding Health Monitoring Centers. The permanent medical data of patients will be kept in the corresponding Home Data Bases, while the measured biomedical data will be sent to the Visitor Health Monitor Center and Visitor Data Base that serves the area of present location of the patient. By combining the measured biomedical data and the permanent medical data, Health Medical Centers will be able to coordinate the needed actions and help the local medical teams to make quickly the best decisions that could be crucial for the patient health, and that can reduce the cost of health service.

  4. Process query systems for network security monitoring

    Science.gov (United States)

    Berk, Vincent; Fox, Naomi

    2005-05-01

    In this paper we present the architecture of our network security monitoring infrastructure based on a Process Query System (PQS). PQS offers a new and powerful way of efficiently processing data streams, based on process descriptions that are submitted as queries. In this case the data streams are familiar network sensors, such as Snort, Netfilter, and Tripwire. The process queries describe the dynamics of network attacks and failures, such as worms, multistage attacks, and router failures. Using PQS the task of monitoring enterprise class networks is simplified, offering a priority-based GUI to the security administrator that clearly outlines events that require immediate attention. The PQS-Net system is deployed on an unsecured production network; the system has successfully detected many diverse attacks and failures.

  5. A Resilient Condition Assessment Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Humberto Garcia; Wen-Chiao Lin; Semyon M. Meerkov

    2012-08-01

    An architecture and supporting methods are presented for the implementation of a resilient condition assessment monitoring system that can adaptively accommodate both cyber and physical anomalies to a monitored system under observation. In particular, the architecture includes three layers: information, assessment, and sensor selection. The information layer estimates probability distributions of process variables based on sensor measurements and assessments of the quality of sensor data. Based on these estimates, the assessment layer then employs probabilistic reasoning methods to assess the plant health. The sensor selection layer selects sensors so that assessments of the plant condition can be made within desired time periods. Resilient features of the developed system are then illustrated by simulations of a simplified power plant model, where a large portion of the sensors are under attack.

  6. System for monitoring microclimate conditions in greenhouse

    Directory of Open Access Journals (Sweden)

    Marković Dušan B.

    2014-01-01

    Full Text Available Monitoring microclimate parameters in different kind of environments has significant contribution to many areas of human activity and production processes. One of them is vegetable production in greenhouses where measurement of its microclimate parameters may influence the decision on taking appropriate action and protect crops. It is also important to preserve optimal condition in greenhouses to facilitate the process of transpiration, plant mineral nutrition and prevent of a variety physiological damage caused by a deficit of some specific nutrients. Systems for monitoring have wide application in the last years thanks to development of modern computer technology. In this paper model of the monitoring system based on smart transducer concept was introduced. Within the system components are based on MSP430 ultra low power micro controllers. They are using wireless communication to exchange data within the system that was structured according to smart transducer concept. User applications from the network could access to system interface using HTTP protocol where web server could be running on the computer or it could be an embedded web server running on micro controller based device.

  7. Evaluation of radon levels in indoor gymnasia of Palermo (Sicily and Sassari (Sardinia

    Directory of Open Access Journals (Sweden)

    Alberto Firenze

    2009-12-01

    Full Text Available

    Background: In the last decades, there has been increased worldwide interest in the management of health risks from indoor radon.

    Methods: From 2006 to 2008, a survey on air radon levels was carried out in a total of 57 indoor gymnasia respectively located in the urban area of Palermo (Sicily and Sassari (Sardinia.

    Results: The indoor radon levels were generally low with different geometric means in the two geographic areas (14.3 Bq/m3 in Palermo and 36 Bq/m3 in Sassari, respectively. Overall, in both groups increasing values of radon were found during the night and the early morning, with radon concentrations significantly lower during working time than at other times. The analysis of structural parameters showed that direct contact with the soil significantly correlated with increased levels of radon in gymnasia located in Palermo’s area (p<0.05. Furthermore, higher radon levels in Sicilian structures were also associated, although not significantly, with lack of sumps (19.3 vs 12.9 Bq/m3, location below the ground level (18.8 vs 8.7 Bq/m3, lack of windows (25 vs 13.2 Bq/m3, presence of forced ventilation (15.5 vs 7.3 Bq/m3 and with cracks or moisture tracks (15.7 vs 13.2 Bq/m3.

    Conclusions: Radon tends to accumulate in indoor sites and it’s monitoring, especially in buildings with potentially overcrowded conditions, could be of public health interest. Mitigation measures and minimization of the number of structural and functional risk parameters should be strongly encouraged in order to limit radon accumulation especially in countries with higher radium concentration in the soil.

  8. Environmental gamma and radon dosimetry in Venezuela

    CERN Document Server

    Sajo-Bohus, L; Urbani, F; Castro, D D; Greaves, E D; Liendo, J A

    1999-01-01

    Environmental gamma exposure and radon concentration levels measured in Venezuelan regions are presented. A new generation image analyser was used for alpha particle track counting in CR-39 detectors. Mineral water wells from where water is supplied for massive consumption have an alpha activity around 0.450 Bq L sup - sup 1 and few of them have concentrations above 50 Bq L sup - sup 1. Coastal potable water activity is on the average around 5.3 +- 12% Bq L sup - sup 1. Indoor radon national average is 36 +- 5% Bq m sup - sup 3; in two of the 36 monitored sites, the measured average is above 400 +- 5% Bq m sup - sup 3. In air gamma dose values are between 100 and 144 nGy h sup - sup 1. In soil, sup 1 sup 3 sup 7 Cs concentration is around 0.5 and 10 Bq kg sup - sup 1 at the depth of down to 20 cm. Building materials were included in this study. sup 7 Be and sup 1 sup 3 sup 7 Cs were measured in low concentration in tropical plants on Tepuy-s (sacred mountains in the Amazonas State). Geological active faults w...

  9. CONSEQUENCES OF USING HOME-MADE RADON SOURCES FOR MEASURING THE RADON DIFFUSION COEFFICIENT.

    Science.gov (United States)

    Dobrovolný, T; Jiránek, M

    2017-11-01

    The applicability of home-made radon sources for determining the radon diffusion coefficient of waterproofing materials was studied for three representatives of materials with a high radium content: uraninite, slag concrete and filter sand. The results of our investigation confirmed that the radon production rate of home-made radon sources is significantly lower than the radon production rate of artificial sources. Consequently, home-made sources are usually unable to generate concentrations higher than 100 kBq/m3 in the source container. Therefore, they cannot be used for determining radon diffusion coefficients lower than 1 × 10-12 m2/s. In addition, when home-made radon sources are used, only time-dependent mathematical solutions of the non-stationary radon diffusion can be used for determining the radon diffusion coefficient from the measured data. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. RADON CONCENTRATION TIME SERIES MODELING AND APPLICATION DISCUSSION.

    Science.gov (United States)

    Stránský, V; Thinová, L

    2017-11-01

    In the year 2010 a continual radon measurement was established at Mladeč Caves in the Czech Republic using a continual radon monitor RADIM3A. In order to model radon time series in the years 2010-15, the Box-Jenkins Methodology, often used in econometrics, was applied. Because of the behavior of radon concentrations (RCs), a seasonal integrated, autoregressive moving averages model with exogenous variables (SARIMAX) has been chosen to model the measured time series. This model uses the time series seasonality, previously acquired values and delayed atmospheric parameters, to forecast RC. The developed model for RC time series is called regARIMA(5,1,3). Model residuals could be retrospectively compared with seismic evidence of local or global earthquakes, which occurred during the RCs measurement. This technique enables us to asses if continuously measured RC could serve an earthquake precursor. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Radon survey in caves from Mallorca Island, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Dumitru, Oana A. [Department of Geology, Babeș-Bolyai University, Kogălniceanu 1, 400084 Cluj-Napoca (Romania); School of Geosciences, University of South Florida, 4202 E. Fowler Ave., NES 107 Tampa (United States); Onac, Bogdan P. [School of Geosciences, University of South Florida, 4202 E. Fowler Ave., NES 107 Tampa (United States); Fornós, Joan J. [Departament de Ciències de la Terra, Universitat de les Illes Balears, Crta. Valldemossa km 7.5, 07122 Palma (Mallorca) (Spain); Cosma, Constantin [Environmental Radioactivity and Nuclear Dating Center, Babeș-Bolyai University, Fântânele 30, 400294 Cluj-Napoca (Romania); Ginés, Angel; Ginés, Joaquín [Departament de Ciències de la Terra, Universitat de les Illes Balears, Crta. Valldemossa km 7.5, 07122 Palma (Mallorca) (Spain); Merino, Antoni [Grup Espeleològic de Llubí, Federació Balear d' Espeleologia, c/Uruguai s/n, Palma Arena, 07010 Palma, Illes Balears (Spain)

    2015-09-01

    This study reports radon concentration in the most representative caves of Mallorca, identifying those in which the recommended action level is exceeded, thus posing health risks. Two show caves (Campanet and Artà) and three non-touristic caves (Font, Drac, Vallgornera) were investigated. Data were collected at several locations within each cave for three different periods, from March 2013 to March 2014. Except for Vallgornera, where only one monitoring period was possible, and Artà in which low values were recorded throughout the year, a clear seasonal variability, with higher values during the warm seasons and lower during winter time is prominent. Radon concentrations differed markedly from one cave to another, as well as within the same cave, ranging from below detection limit up to 3060 Bq·m{sup −3}. The results of this study have significant practical implications, making it possible to provide some recommendation to cave administrators and other agencies involved in granting access to the investigated caves. - Highlights: • A survey of radon was carried out in caves from Mallorca, Spain using CR 39 detectors. • Three different seasons are covered: spring, summer, and winter. • Radon level ranges from below detection limit up to 3060 Bq·m{sup −3}. • Seasonal variation is evident (higher values in summer and lower during winter). • Particular recommendations were made to each cave administration.

  12. Factors affecting yearly variations of indoor radon concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Steck, D.J.; Baynes, S.A. [John`s Univ., Collegeville, MN (United States)

    1996-06-01

    Since indoor radon exposures take place over many years while radon measurement periods are shorter, we are studying the yearly variation of indoor radon concentrations in approximately 100 houses located throughout Minnesota. Most houses were initially measured for one or more years in the late 1980`s and for 5 consecutive years starting in 1990. Two houses have been monitored for 12 y. Each year, two alpha track detectors were placed on the two lowest livable levels. The year-to-year variations averaged about 35% (corrected for instrumental uncertainties) in both basements and first floors. The minimum observed variation was 5% and the maximum was 130%. Some homes have shown substantial variation associated with Structural modifications. While most homes show no obvious systematic trends, a few houses have shown temporal trends that may be associated with aging or climate. We are studying possible correlation between year-to-year radon variation, climatic variables (yearly-average and seasonal such as heating/cooling degree days, precipitation, soil moisture), and structural changes.

  13. Modelling radon progeny concentration variations in thermal spas.

    Science.gov (United States)

    Nikolopoulos, Dimitrios; Vogiannis, Efstratios

    2007-02-01

    Radon and its short-lived progenies (218Po, 214Pb, 214Bi and 214Po) are well known radioactive indoor pollutants identified as the major radiation burden component of the thermal spa users. Monitoring of short-lived progeny concentration is of great importance for short-term dose estimations both for bathers and working personnel. A prediction model of the short-lived progeny concentration variations was developed and applied on published data of the thermal spas of Lesvos Island. The physical procedures involved were modeled in a set of differential equations describing radon progeny concentration variations on the basis of radon measurements. Published daughter data were fitted on model predictions adjusting non-measured parameters, e.g. attachment and deposition rate constants for attached and unattached progenies. Attachment rate constants were estimated between 50 and 200 h-1 while the deposition rate constants between 0.25 and 5 h-1 for attached progenies and 0.5 and 170 h-1 for the unattached ones. In addition, unattached 218Po, 214Pb and 214Bi progenies were found to be shifted forward in respect to radon approximately 0.001 h, 0.05 h and 0.40 h respectively, while attached 218Po, 214Pb and 214Bi progenies 0.05 h, 0.45 h and 0.65 h respectively.

  14. Radon activity in Saudi houses

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Al-Jarallah, M.I. (University of Petroleum and Minerals, Dhahran (Saudi Arabia). Dept. of Physics)

    1984-01-01

    Long term measurements of radon's concentrations inside Saudi houses being studied using CR-39 Plastic Track Detectors fixed inside sealed plastic cups. The cups were left for about 7 months in the houses. The measurements were done in different cities of different provinces in the country. The analysis of 636 cups showed that the radon concentration in different cities was ranging from 0.27 pCi/l (in Khobar) to 0.98 pCi/l (in Taif). In exceptional places in Eastern Province, it is found that the lowest concentration was in the University offices (0.13 pCi/l) and the highest was in the University unoccupied houses (0.81 pCi/l). It is found that the ventilation is the main factor affecting the radon concentration in houses.

  15. Knowledge based systems for condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, J.R.; Burt, G.M.; Moyes, A.

    1997-12-31

    A key issue in the operation of power system plant is deriving maximum financial benefit while staying within technical, contractual and regulatory constraints. Moreover, the capital investment required for much power system plant necessitates high levels of plant availability to make a reasonable rate-of-return. Thus, the minimisation of operational costs resulting from unplanned plant outages, unnecessary maintenance and under-utilisation of plant capabilities has become a core objective of power system plant operation. Rationalisation of power system control functions has resulted in the use of centralised control rooms from which large and complex power systems are operated. Extensive measurement, monitoring and control systems have been developed which provide operators with data from which power system plant behaviour can be evaluated. However, in the event of a serious operational incident, significant amounts of data are generated. Under such circumstances it has been found that operators are inhibited in assessing the situation, and hence the effectiveness of the subsequent operational response can be reduced. The role of knowledge based systems (KBSs) in condition monitoring is to support operational decision making through the provision of timely and focused information. (Author)

  16. Non Invasive Glucose Monitoring System Using Nanosensors

    Directory of Open Access Journals (Sweden)

    Rajasekaran C.

    2016-03-01

    Full Text Available The most existing future technology is an outcome of the fields of computer science, electronics and Biology. Health inequalities have become the focus of a number of descriptive and analytical studies. One of the health related problem is diabetes. Diabetes at its serious stage leads to blindness. Monitoring glucose level in blood is one preventive measure to check diabetes. Increase in Glucose is a common risk factor which leads to hyperglycemia, Hypoglycemia, heart attack, stokes and aneurysms. A glucose monitoring system continuously measures and monitors the glucose level in a patient’s blood. Normal blood glucose level of human is 70-110 milligram/deciliter. The level is maintained by using the secretion of insulin inside the body. When the insulin level gets increased it leads to hyperglycemia, and hypoglycemia when the level gets decreased. Hyperglycemia disease includes cataract,edema, hypertension, polyuria and polydipsia. Hypoglycemaia disease includes confusion, giddiness, unconsciousness, coma and death. The proposed system finds a new way for measuring the glucose level. The work uses Nanopellets which measure’s the glucose level, when the glucose level gets increased or decreased, it will be automatically get monitored and processed using microcontroller (MSP430G2553. The information is then send to the doctor through GSM.

  17. Thermo-diffusional radon waves in soils

    Energy Technology Data Exchange (ETDEWEB)

    Minkin, Leonid, E-mail: lminkin@pcc.edu [Portland Community College, 12000 SW 49th Ave, Portland, OR 97219 (United States); Shapovalov, Alexander S. [Saratov State University, 83 Astrakhanskay Street, Saratov 410012 (Russian Federation)

    2016-09-15

    A new theoretical framework for diurnal and seasonal oscillations of the concentration of radon in soil and open air is proposed. The theory is based on the existing temperature waves in soils and thermo-diffusional gas flux in porous media. As soil is a non-isothermal porous medium, usually possessing a large fraction of microscopic pores belonging to Knudsen's free molecular field, a thermo-diffusional gas flow in soil has to arise. The radon mass transfer equation in soil for sinusoidal temperature oscillations at the soil–atmosphere boundary is solved, which reveals that radon concentration behaves as a damped harmonic wave. The amplitude of radon concentration oscillations and phase shift between radon concentration oscillations and soil temperature depend on the radon diffusion coefficient in soil, rate of radon production, soil thermal conductivity, average soil temperature, decay constant, and heat of radon transfer. Primarily numerical calculations are presented and comparisons with experimental data are shown. - Highlights: • Temperature oscillations in atmosphere generate radon waves in soil. • Radon flux in atmosphere is a harmonic function of time. • Radon concentration waves in soil have the same frequency as the temperature waves.

  18. Valve Health Monitoring System Utilizing Smart Instrumentation

    Science.gov (United States)

    Jensen, Scott L.; Drouant, George J.

    2006-01-01

    The valve monitoring system is a stand alone unit with network capabilities for integration into a higher level health management system. The system is designed for aiding in failure predictions of high-geared ball valves and linearly actuated valves. It performs data tracking and archiving for identifying degraded performance. The data collection types are cryogenic cycles, total cycles, inlet temperature, body temperature torsional strain, linear bonnet strain, preload position, total travel and total directional changes. Events are recorded and time stamped in accordance with the IRIG B True Time. The monitoring system is designed for use in a Class 1 Division II explosive environment. The basic configuration consists of several instrumentation sensor units and a base station. The sensor units are self contained microprocessor controlled and remotely mountable in three by three by two inches. Each unit is potted in a fire retardant substance without any cavities and limited to low operating power for maintaining safe operation in a hydrogen environment. The units are temperature monitored to safeguard against operation outside temperature limitations. Each contains 902-928 MHz band digital transmitters which meet Federal Communication Commission's requirements and are limited to a 35 foot transmission radius for preserving data security. The base-station controller correlates data from the sensor units and generates data event logs on a compact flash memory module for database uploading. The entries are also broadcast over an Ethernet network. Nitrogen purged National Electrical Manufactures Association (NEMA) Class 4 enclosures are used to house the base-station

  19. Honey Bee Colonies Remote Monitoring System

    Directory of Open Access Journals (Sweden)

    Sergio Gil-Lebrero

    2016-12-01

    Full Text Available Bees are very important for terrestrial ecosystems and, above all, for the subsistence of many crops, due to their ability to pollinate flowers. Currently, the honey bee populations are decreasing due to colony collapse disorder (CCD. The reasons for CCD are not fully known, and as a result, it is essential to obtain all possible information on the environmental conditions surrounding the beehives. On the other hand, it is important to carry out such information gathering as non-intrusively as possible to avoid modifying the bees’ work conditions and to obtain more reliable data. We designed a wireless-sensor networks meet these requirements. We designed a remote monitoring system (called WBee based on a hierarchical three-level model formed by the wireless node, a local data server, and a cloud data server. WBee is a low-cost, fully scalable, easily deployable system with regard to the number and types of sensors and the number of hives and their geographical distribution. WBee saves the data in each of the levels if there are failures in communication. In addition, the nodes include a backup battery, which allows for further data acquisition and storage in the event of a power outage. Unlike other systems that monitor a single point of a hive, the system we present monitors and stores the temperature and relative humidity of the beehive in three different spots. Additionally, the hive is continuously weighed on a weighing scale. Real-time weight measurement is an innovation in wireless beehive—monitoring systems. We designed an adaptation board to facilitate the connection of the sensors to the node. Through the Internet, researchers and beekeepers can access the cloud data server to find out the condition of their hives in real time.

  20. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    Energy Technology Data Exchange (ETDEWEB)

    Mjoenes, L

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure.

  1. An integrated system for pipeline condition monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Strong, Andrew P.; Lees, Gareth; Hartog, Arthur; Twohig, Richard; Kader, Kamal; Hilton, Graeme; Mullens, Stephen; Khlybov, Artem [Schlumberger, Southampton (United Kingdom); Sanderson, Norman [BP Exploration, Sunbury (United Kingdom)

    2009-07-01

    In this paper we present the unique and innovative 'Integriti' pipeline and flow line integrity monitoring system developed by Schlumberger in collaboration with BP. The system uses optical fiber distributed sensors to provide simultaneous distributed measurements of temperature, strain and vibration for the detection, monitoring, and location of events including: Third Party Interference (TPI), including multiple simultaneous disturbances; geo-hazards and landslides; gas and oil leaks; permafrost protection. The Integriti technology also provides a unique means for tracking the progress of cleaning and instrumented pigs using existing optical telecom and data communications cables buried close to pipelines. The Integriti solution provides a unique and proactive approach to pipeline integrity management. It performs analysis of a combination of measurands to provide the pipeline operator with an event recognition and location capability, in effect providing a hazard warning system, and offering the operator the potential to take early action to prevent loss. Through the use of remote, optically powered amplification, an unprecedented detection range of 100 km is possible without the need for any electronics and therefore remote power in the field. A system can thus monitor 200 km of pipeline when configured to monitor 100 km upstream and downstream from a single location. As well as detecting conditions and events leading to leaks, this fully integrated system provides a means of detecting and locating small leaks in gas pipelines below the threshold of present online leak detection systems based on monitoring flow parameters. Other significant benefits include: potential reductions in construction costs; enhancement of the operator's existing integrity management program; potential reductions in surveillance costs and HSE risks. In addition to onshore pipeline systems this combination of functionality and range is available for practicable

  2. Fluctuations in indoor radon levels in dwellings in a volcanic area of a temperate tropical region

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Ruiz, W.; Pena, P. [ININ, Mexico D.F. (Mexico); Ponciano, G.; Morales, V. [Dr. Manuel Gea Gonzalez General Hospital, Secretaria de Salud and Dept. of Pharmacology - UNAM (Mexico); Godinez, L. [IG-UNAM, Ciudad Univ., Mexico D.F. (Mexico)

    2002-03-01

    Mexico City is located in the central section of the Neo-Volcanic Mexican Belt at an altitude of 2240 m. Air pollution is currently a huge environmental problem in the city. With the aim of determining any anomalous behavior patterns in relation to indoor radon, which could possibly have had an effect on patients with lung diseases who are smokers, a study was performed in indoor atmospheres over a period of several months. Radon was measured using both passive and continuous radon monitoring devices. The results of our investigations indicate that the dwellings of patients with lung diseases show no special characteristics as compared to homes included in a control group. However, in both cases, an enhancement in the indoor radon concentration levels during the night and early morning periods was observed, the periods in which most people are at home resting. (orig.)

  3. Radon og lungekreft i Norge

    OpenAIRE

    Enger, Ingvild-M.A

    2011-01-01

    Sammendrag Denne masteroppgaven ”Radon og lungekreft i Norge” inneholder to deler; den første delen inneholder en introduksjon til studien med utdypende empiri og teori i en større sammenheng. Den andre delen er artikkelen ” Sammenhengen mellom forekomst av lungekreft og radon målt i bolig hus – en økologisk studie”. Siste del skal sendes til Tidsskriftet for Den norske legeforening for publisering. Formålet med denne studien var å undersøke om det var høyere forekomst av lungekreft bla...

  4. THE NATIONAL RADON ARCHIVE AS A USEFUL TOOL FOR DEVELOPING AND UPDATING THE NATIONAL RADON ACTION PLAN.

    Science.gov (United States)

    Bochicchio, F; Antignani, S; Carpentieri, C; Ampollini, M; Caccia, B; Pozzi, S; Venoso, G

    2017-11-01

    International recommendations and regulations require developing of National Radon Action Plans (NRAPs) to effectively manage the protection of workers and population from radon exposure. In Italy, a NRAP was published in 2002 and several activities have been carried out in this framework. Information and data regarding these and previous activities have been collected in a National Radon Archive (NRA). Activities carried out by institutionally involved institutes and agencies include several national and regional surveys, involving more than 50 000 indoor environments (dwellings, schools and workplaces), and remedial actions performed in ~350 buildings, largely in schools. Data collected in the NRA allowed also to estimate that lung cancer deaths attributable to radon exposure in Italy are ~3400 per year. On-going developments of the Italian NRA finalized to effectively use it as tool for developing, monitoring and updating the NRAP are also described. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Chomont, Arthur Rene; The ATLAS collaboration

    2016-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs), located on the outside of the calorimeter. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser and charge injection elements and it allows to monitor and equalize the calorimeter response at each stage of the signal production, from scin...

  6. Thoron detection with an active Radon exposure meter—First results

    Energy Technology Data Exchange (ETDEWEB)

    Irlinger, J., E-mail: josef.irlinger@helmholtz-muenchen.de; Wielunski, M.; Rühm, W. [ISS, Helmholtz Center Munich, Research Center for Environment and Health, 85764 Neuherberg (Germany)

    2014-02-15

    For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11 Bq m{sup −3} Radon atmosphere or by a 15 Bq m{sup −3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

  7. PRODUCTION MONITORING SYSTEM WITH PREDICTIVE FUNCTIONALITY

    Directory of Open Access Journals (Sweden)

    TANEL EISKOP

    2017-09-01

    Full Text Available The main objective of the current study is to analyse and develop production monitoring system (PMS for small and medium enterprises (SME with predictive functionality. The development of planned PMS covers design of hardware architecture, building data analysis and prediction tools. New tool wear forecast model has been developed. The proposed model extends traditional widely used models by introducing the effects of working regimes and multiple passes on tool/component wear.

  8. Radon Reduction Techniques in Schools: Interim Technical Guidance.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    This technical document is intended to assist school facilities maintenance personnel in the selection, design, and operation of radon reduction systems in schools. The guidance contained in this document is based largely on research conducted in 1987 and 1988 in schools located in Maryland and Virginia. Researchers from the United States…

  9. Radon concentration: A tool for assessing the fracture network at ...

    African Journals Online (AJOL)

    drinie

    2003-01-01

    Jan 1, 2003 ... geothermal systems. In: Ivanovich M and Harmon RS(eds.) Uranium. Series Disequilibrium: Applications to Earth, Marine and Environ- mental Sciences. Clarendon Press, Oxford. 631-668. LEVIN M (2000 ) The radon emanation technique as a tool in ground water exploration. Borehole Water J. 46 22-26.

  10. 3M Personal Air Monitoring Systems

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    3M monitors are made to allow sample desorption directly in the monitor itself. The monitor comes with a snap-on elution cap that permits the desorbing solvent to be injected into the monitor. The solution is then poured into sample vials for analysis. 3M monitors use standard analytical methods: gas chromatography for the organic vapor monitor and ethylene oxide monitor, and colorimetry for the formaldehyde monitor.

  11. Transient radon signals driven by fluid pressure pulse, micro-crack closure, and failure during granite deformation experiments

    Science.gov (United States)

    Girault, Frédéric; Schubnel, Alexandre; Pili, Éric

    2017-09-01

    In seismically active fault zones, various crustal fluids including gases are released at the surface. Radon-222, a radioactive gas naturally produced in rocks, is used in volcanic and tectonic contexts to illuminate crustal deformation or earthquake mechanisms. At some locations, intriguing radon signals have been recorded before, during, or after tectonic events, but such observations remain controversial, mainly because physical characterization of potential radon anomalies from the upper crust is lacking. Here we conducted several month-long deformation experiments under controlled dry upper crustal conditions with a triaxial cell to continuously monitor radon emission from crustal rocks affected by three main effects: a fluid pressure pulse, micro-crack closure, and differential stress increase to macroscopic failure. We found that these effects are systematically associated with a variety of radon signals that can be explained using a first-order advective model of radon transport. First, connection to a source of deep fluid pressure (a fluid pressure pulse) is associated with a large transient radon emission increase (factor of 3-7) compared with the background level. We reason that peak amplitude is governed by the accumulation time and the radon source term, and that peak duration is controlled by radioactive decay, permeability, and advective losses of radon. Second, increasing isostatic compression is first accompanied by an increase in radon emission followed by a decrease beyond a critical pressure representing the depth below which crack closure hampers radon emission (150-250 MPa, ca. 5.5-9.5 km depth in our experiments). Third, the increase of differential stress, and associated shear and volumetric deformation, systematically triggers significant radon peaks (ca. 25-350% above background level) before macroscopic failure, by connecting isolated cracks, which dramatically enhances permeability. The detection of transient radon signals before rupture

  12. A system approach to nuclear facility monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Argo, P.E.; Doak, J.E.; Howse, J.W.

    1996-09-01

    Sensor technology for use in nuclear facility monitoring has reached and advanced stage of development. Research on where to place these sensors in a facility and how to combine their outputs in a meaningful fashion does not appear to be keeping pace. In this paper, we take a global view of the problem where sensor technology is viewed as only one piece of a large puzzle. Other pieces of this puzzle include the optimal location and type of sensors used in a specific facility, the rate at which sensors record information, and the risk associated with the materials/processes at a facility. If the data are analyzed off-site, how will they be transmitted? Is real-time analysis necessary? Are we monitoring only the facility itself, or might we also monitor the processing that occurs there? How are we going to combine the output from the various sensors to give us an accurate picture of the state of the facility? This paper will not try to answer all these questions, but rather it will attempt to stimulate thought in this area by formulating a systems approach to the problem demonstrated by a prototype system and a systems proposed for an actual facility. Our focus will be on the data analysis aspect of the problem.

  13. A remote drip infusion monitoring system employing Bluetooth.

    Science.gov (United States)

    Amano, Hikaru; Ogawa, Hidekuni; Maki, Hiromichi; Tsukamoto, Sosuke; Yonezawa, Yoshiharu; Caldwell, W Morton

    2012-01-01

    We have developed a remote drip infusion monitoring system for use in hospitals. The system consists of several infusion monitoring devices and a central monitor. The infusion monitoring device employing a Bluetooth module can detect the drip infusion rate and an empty infusion solution bag, and then these data are sent to the central monitor placed at the nurses' station via the Bluetooth. The central monitor receives the data from several infusion monitoring devices and then displays graphically them. Therefore, the developed system can monitor intensively the drip infusion situation of the several patients at the nurses' station.

  14. 76 FR 72006 - Draft Interim Staff Guidance: Evaluations of Uranium Recovery Facility Surveys of Radon and Radon...

    Science.gov (United States)

    2011-11-21

    ... COMMISSION Draft Interim Staff Guidance: Evaluations of Uranium Recovery Facility Surveys of Radon and Radon... Recovery Facility Surveys of Radon and Radon Progeny in Air and Demonstrations of Compliance with 10 CFR 20... that existing guidance does not sufficiently detail how the NRC staff reviews surveys of radon and...

  15. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  16. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  17. Monitoring system and methods for a distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  18. Development of a highly sensitive radon-222 amplifier (HiSRA) for low-level atmospheric measurements.

    Science.gov (United States)

    Topin, Sylvain; Richon, Patrick; Thomas, Vincent; Gréau, Claire; Pujos, Julie; Moulin, Julien; Hovesepian, Alexandre; Deliere, Ludovic

    2017-05-01

    Radon ((222)Rn), a radioactive gas with a half-life of 3.82 days, is continuously emanated from soil, rocks, and water by the radioactive decay of (226)Ra. Radon-222 is released from the ground into the atmosphere, where it is transported mainly by turbulent diffusion or convection. For precise measurement of radon-222 atoms in the atmosphere, the detectors typically used present a small volume or surface area and are therefore not very sensitive, especially for online measurements and short sample intervals (Radon Amplifier (HiSRA) consisting in an enrichment system placed prior to a classic radon-222 analyzer. This system uses permeation membranes that make it possible to treat large quantities of air online (30 m(3) h(-1)). The radon-222 concentration is increased instantaneously by at least a factor of 30 across the HiSRA system. Therefore, in this study, when coupling to an ionization chamber (AlphaGUARDTM) at the outlet of the HiSRA system, the detection limit of the overall system is multiplied by factor of 30 and induces a new LD for a radon 222 gas analyzer lower than 1 Bq m(-3) for an integrating time of 10 min and 0.1 Bq m(-3) for 1 h. We constructed one radon amplifier prototype that provided the preliminary results for amplification efficiency and the initial measurements presented herein. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Nutrient Film Technique (NFT Hydroponic Monitoring System

    Directory of Open Access Journals (Sweden)

    Helmy Helmy

    2016-10-01

    Full Text Available Plant cultivation using hydroponic is very popular today. Nutrient Film Technique (NFT hydroponic system is commonly used by people. It can be applied indoor or outdoor. Plants in this systemneed nutrient solution to grow well. pH, TDS and temperature of the nutrient solution must be check to ensure plant gets sufficient nutrients. This research aims todevelop monitoring system of NFT hydroponic. Farmer will be able to monitor pH, TDS and temperature online. It will ease farmer to decide which plant is suitable to be cultivated and time to boost growth.Delay of the system will be measured to know system performance. Result shows that pH is directly proportional with TDS. Temperature value has no correlation with pH and TDS. System has highest delay during daylight and afternoon but it will decline in the night and morning. Average of delay in the morning is 11 s, 28.5 s in daylight, 32 s in the afternoon and 17.5 s in the night.

  20. Residential radon in Galicia: a cross-sectional study in a radon-prone area.

    Science.gov (United States)

    Lorenzo-González, María; Ruano-Ravina, Alberto; Peón, Joaquín; Piñeiro, María; Barros-Dios, Juan Miguel

    2017-09-01

    Residential radon exposure is a major public health problem. It is the second greatest cause of lung cancer, after smoking, and the greatest in never-smokers. This study shows the indoor radon exposure distribution in Galicia and estimates the percentage of dwellings exceeding reference levels. It is based on 3245 residential radon measurements obtained from the Galician Radon Map project and from controls of two previous case-control studies on residential radon and lung cancer. Results show a high median residential radon concentration in Galicia (99 Bq m -3 ), with 49.3% of dwellings having a radon concentration above 100 Bq m -3 and 11.1% having a concentration above 300 Bq m -3 . Ourense and Pontevedra, located in South Galicia, are the provinces with the highest median indoor radon concentrations (137 Bq m -3 and 123.5 Bq m -3 , respectively). Results also show lower radon levels in progressively higher building storeys. These high residential radon concentrations confirm Galicia as a radon-prone area. A policy on radon should be developed and implemented in Galicia to minimize the residential radon exposure of the population.

  1. Downhole Vibration Monitoring and Control System

    Energy Technology Data Exchange (ETDEWEB)

    Martin E. Cobern

    2007-09-30

    The objective of this program is to develop a system to both monitor the vibration of a bottomhole assembly, and to adjust the properties of an active damper in response to these measured vibrations. The key feature of this system is its use of a magnetorheological fluid (MRF) to allow the damping coefficient to be changed extensively, rapidly and reversibly without the use of mechanical valves, but only by the application of a current. Phase I of this program, which entailed modeling and design of the necessary subsystems and design, manufacture and test of a full laboratory prototype, was completed on May 31, 2004. Much of the effort was devoted to the design and testing of the MRF damper, itself. The principal objectives of Phase II were: more extensive laboratory testing, including the evaluation of different feedback algorithms for control of the damper; design and manufacture of a field prototype system; and, testing of the field prototype in a drilling laboratory. Phase II concluded on January 31, 2006, and a final report was issued. Work on Phase III of the project began during the first quarter, 2006, with the objectives of building precommercial prototypes, testing them in a drilling laboratory and the field; developing and implementing a commercialization plan. All of these have been accomplished. The Downhole Vibration Monitoring & Control System (DVMCS) prototypes have been successfully proven in testing at the TerraTek drilling facility and at the Rocky Mountain Oilfield Test Center (RMOTC.) Based on the results of these tests, we have signed a definitive development and distribution agreement with Smith, and commercial deployment is underway. This current version of the DVMCS monitors and controls axial vibrations. Due to time and budget constraints of this program, it was not possible to complete a system that would also deal with lateral and torsional (stick-slip) vibrations as originally planned; however, this effort is continuing without DOE

  2. Radon and aerosol release from open-pit uranium mining

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, V.W.; Nielson, K.K.; Mauch, M.L.

    1982-08-01

    The quantity of /sup 222/Rn (hereafter called radon) released per unit of uranium produced from open pit mining has been determined. A secondary objective was to determine the nature and quantity of airborne particles resulting from mine operations. To accomplish these objectives, a comprehensive study of the release rates of radon and aerosol material to the atmosphere was made over a one-year period from April 1979 to May 1980 at the Morton Ranch Mine which was operated by United Nuclear Corporation (UNC) in partnership with Tennessee Valley Authority (TVA). The mine is now operated for TVA by Silver King Mines. Morton Ranch Mine was one of five open pit uranium mines studied in central Wyoming. Corroborative measurements were made of radon flux and /sup 226/Ra (hereafter called radium) concentrations of various surfaces at three of the other mines in October 1980 and again at these three mines plus a fourth in April of 1981. Three of these mines are located in the Powder River Basin, about 80 kilometers east by northeast of Casper. One is located in the Shirley Basin, about 60 km south of Casper, and the remaining one is located in the Gas Hills, approximately 100 km west of Casper. The one-year intensive study included simultaneous measurement of several parameters: continuous measurement of atmospheric radon concentration near the ground at three locations, monthly 24-hour radon flux measurements from various surfaces, radium analyses of soil samples collected under each of the flux monitoring devices, monthly integrations of aerosols on dichotomous aerosol samplers, analysis of aerosol samplers for total dust loading, aerosol elemental and radiochemical composition, aerosol elemental composition by particle size, wind speed, wind direction, temperature, barometric pressure, and rainfall.

  3. Global integrated drought monitoring and prediction system

    Science.gov (United States)

    Hao, Zengchao; AghaKouchak, Amir; Nakhjiri, Navid; Farahmand, Alireza

    2014-01-01

    Drought is by far the most costly natural disaster that can lead to widespread impacts, including water and food crises. Here we present data sets available from the Global Integrated Drought Monitoring and Prediction System (GIDMaPS), which provides drought information based on multiple drought indicators. The system provides meteorological and agricultural drought information based on multiple satellite-, and model-based precipitation and soil moisture data sets. GIDMaPS includes a near real-time monitoring component and a seasonal probabilistic prediction module. The data sets include historical drought severity data from the monitoring component, and probabilistic seasonal forecasts from the prediction module. The probabilistic forecasts provide essential information for early warning, taking preventive measures, and planning mitigation strategies. GIDMaPS data sets are a significant extension to current capabilities and data sets for global drought assessment and early warning. The presented data sets would be instrumental in reducing drought impacts especially in developing countries. Our results indicate that GIDMaPS data sets reliably captured several major droughts from across the globe. PMID:25977759

  4. Global integrated drought monitoring and prediction system.

    Science.gov (United States)

    Hao, Zengchao; AghaKouchak, Amir; Nakhjiri, Navid; Farahmand, Alireza

    2014-01-01

    Drought is by far the most costly natural disaster that can lead to widespread impacts, including water and food crises. Here we present data sets available from the Global Integrated Drought Monitoring and Prediction System (GIDMaPS), which provides drought information based on multiple drought indicators. The system provides meteorological and agricultural drought information based on multiple satellite-, and model-based precipitation and soil moisture data sets. GIDMaPS includes a near real-time monitoring component and a seasonal probabilistic prediction module. The data sets include historical drought severity data from the monitoring component, and probabilistic seasonal forecasts from the prediction module. The probabilistic forecasts provide essential information for early warning, taking preventive measures, and planning mitigation strategies. GIDMaPS data sets are a significant extension to current capabilities and data sets for global drought assessment and early warning. The presented data sets would be instrumental in reducing drought impacts especially in developing countries. Our results indicate that GIDMaPS data sets reliably captured several major droughts from across the globe.

  5. Modelling and experimental study of the behavior of radon and radon decay products in an enclosure. Application to houses; Modelisation et etude experimentale du comportement du radon et de ses descendants dans une enceinte confinee. Application a une habitation

    Energy Technology Data Exchange (ETDEWEB)

    Gouronnec, A.M.

    1995-02-03

    Since the eighties, more and more studies were performed about radon and its decay products in houses with one of the aim being the estimation of the dose received by their inhabitants. Then, the principal objective of this work is to describe the behaviour of radon and its decay products within a dwelling. In the first part to the report, a few definitions are given and data from literature give an idea of indoor radon and radon decay products activities and/or size distribution. Aspects of dosimetry are presented too. In the second part of the work, a mathematical model, called `PRADDO` of Physic of Radon and radon Decay products in Domestic environment is developed on the basis of the classical model written by Jacobi in 1972. On the one hand, it has to predict radon decay products activities in systems consisting in one or more enclosure(s), from radon activity and from ambient aerosol concentration and size distribution. On the other hand, one part of the model is assigned to study the influence of the entry model parameters variation on the calculated quantities. Then, in the third part of the work, two experimental studies are realised in order to compare measurements to modelization. The first experimentation is a laboratory work, made on the test bench ICARE from IPSN, and the second one consists in describing the basement of an occupied house from Brittany. In the two cases, the comparison between experiments and modelling shows a good agreement if particles are present in the air, but any conclusion is made when is no aerosol in the enclosure. (author). 158 refs., 81 figs., 42 tabs.

  6. Radiation portal monitor system and method

    Science.gov (United States)

    Morris, Christopher [Los Alamos, NM; Borozdin, Konstantin N [Los Alamos, NM; Green, J Andrew [Los Alamos, NM; Hogan, Gary E [Los Alamos, NM; Makela, Mark F [Los Alamos, NM; Priedhorsky, William C [Los Alamos, NM; Saunders, Alexander [Los Alamos, NM; Schultz, Larry J [Los Alamos, NM; Sossong, Michael J [Los Alamos, NM

    2009-12-15

    A portal monitoring system has a cosmic ray charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray muons, whilst also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  7. Cardiomed System for Medical Monitoring Onboard ISS

    Science.gov (United States)

    Lloret, J. C.; Aubry, P.; Nguyen, L.; Kozharinov, V.; Grachev, V.; Temnova, E.

    2008-06-01

    Cardiomed system was developed with two main objectives: (1) cardiovascular medical monitoring of cosmonauts onboard ISS together with LBNP countermeasure; (2) scientific study of the cardio-vascular system in micro-gravity. Cardiomed is an integrated end-to-end system, from the onboard segment operating different medical instruments, to the ground segment which provides real-time telemetry of on-board experiments and off-line analysis of physiological measurements. In the first part of the paper, Cardiomed is described from an architecture point of view together with some typical uses. In the second part, the most constraining requirements with respect to system design are introduced. Some requirements are generic; some are specific to medical follow-up, others to scientific objectives. In the last part, the main technical challenges which were addressed during the development and the qualification of Cardiomed and the lessons learnt are presented.

  8. Wireless Nde Sensor System for Continuous Monitoring

    Science.gov (United States)

    Dib, G.; Mhamdi, L.; Khan, T.; Udpa, L.; Lajnef, N.; Hong, J.-W.; Udpa, S.; Ramuhalli, P.; Balasubramaniam, K.

    2011-06-01

    For continuous monitoring of power-plant components, the use of in-situ sensors (i.e., sensors that are permanently mounted on the structure) is necessary. In-situ wired sensors require an unrealistic amount of cabling for power and data transfer, which can drive up costs of installation and maintenance. In addition, the use of cabling in hostile environments (high temperature/pressure environments) is not a viable option. This paper presents a wireless system for continuous monitoring, identification of anomalous events, NDE data acquisition and data transfer. NDE sensors are integrated with a wireless radio unit such as a MICA mote. Measurements from the sensors are typically acquired at prescribed intervals, encoded and compressed, and transmitted to a central processing server, where appropriate signal processing techniques may be used to filter out noise in the measurements, enhance the desired signal and quantify the damage in terms of severity.

  9. [Ecological monitoring in agro-ecological systems].

    Science.gov (United States)

    Baĭkov, B D

    1983-01-01

    The fundamental principles of the ecologic monitoring in the antropogenic ecosystems are dealt with. Analyzed are the structure and function of the agroecologic systems, and, on the basis of the particular aspects established a concept is developed of the ecologic control at autoecologic and biocoenologic level. An analysis is likewise made of the ecologic sequelae resulting from the chemical war launched by the American aggressors in Vietnam and the specific trends therefrom in the substantiation of the ecologic monitoring. Stated is the necessity of profound investigations to establish the bioaccumulation of dioxine, a poisonous agent which was contained in herbicides and defoliants used in the war, and which was distinguished by exclusively high toxicity, producing teratogenic and cancerogenic effects and possessing high resistance in the environment.

  10. Effects of bedrock type on the indoor radon concentrations at the office buildings in Gyeongju, Korea

    Directory of Open Access Journals (Sweden)

    Park Hee Chan

    2011-01-01

    Full Text Available This study measured the indoor radon concentrations at 23 administrative office buildings in Gyeongju, Korea, which consists of 23 administrative districts. Using the Korean geological information system, the type of bedrock under the administrative office buildings was identified and classified in 3 major types: granite, sedimentary rock, and sedimentary rock-based fault. The changes in the indoor concentrations at the 23 administrative office buildings were analyzed according to the type of bedrock. As a result, the radon concentration in the areas with the granite bedrock was generally higher than that in the region of two other types of bedrock. In addition, the radon concentration was evaluated according to surface area and construction timing of the building. The indoor radon concentration generally increased with decreasing surface area of the building, particularly in granite distributed areas. For a building aged more than 15 years, the radon concentration in the building in the granite area was much higher. For the building aged 1 or 2 years, the radon concentration was high regardless of the type of the bedrock due to radon emanation from the building material, such as concrete.

  11. 14 CFR 171.267 - Glide path automatic monitor system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Glide path automatic monitor system. 171... Landing System (ISMLS) § 171.267 Glide path automatic monitor system. (a) The ISMLS glide path equipment must provide an automatic monitor system that transmits a warning to designated local and remote...

  12. 14 CFR 171.263 - Localizer automatic monitor system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Localizer automatic monitor system. 171.263... System (ISMLS) § 171.263 Localizer automatic monitor system. (a) The ISMLS localizer equipment must provide an automatic monitor system that transmits a warning to designated local and remote control points...

  13. Applied Data Analysis in Energy Monitoring System

    Directory of Open Access Journals (Sweden)

    Kychkin А.V.

    2016-08-01

    Full Text Available Software and hardware system organization is presented as an example for building energy monitoring of multi-sectional lighting and climate control / conditioning needs. System key feature is applied office energy data analysis that allows to provide each type of hardware localized work mode recognition. It is based on general energy consumption profile with following energy consumption and workload evaluation. Applied data analysis includes primary data processing block, smoothing filter, time stamp identification block, clusterization and classification blocks, state change detection block, statistical data calculation block. Time slot consumed energy value and slot time stamp are taken as work mode classification main parameters. Energy data applied analysis with HIL and OpenJEVis visualization system usage experimental research results for chosen time period has been provided. Energy consumption, workload calculation and eight different states identification has been executed for two lighting sections and one climate control / conditioning emulating system by integral energy consumption profile. Research has been supported by university internal grant №2016/PI-2 «Methodology development of monitoring and heat flow utilization as low potential company energy sources».

  14. Modeling of lung cancer risk due to radon exhalation of granite stone in dwelling houses

    Directory of Open Access Journals (Sweden)

    Akbar Abbasi

    2017-01-01

    Conclusions: The estimated numbers of lung cancer deaths attributable to indoor radon due to granite stones in 2013 were 145 (3.33% and 103 (2.37% for poor and normal ventilation systems, respectively. According to our estimations, the values of 3.33% and 2.37% of lung cancer deaths in 2013 are attributed to radon exhalation of granite stones with poor and normal ventilation systems, respectively.

  15. Radon safety in terms of energy efficiency classification of buildings

    Science.gov (United States)

    Vasilyev, A.; Yarmoshenko, I.; Zhukovsky, M.

    2017-06-01

    According to the results of survey in Ekaterinburg, Russia, indoor radon concentrations above city average level have been found in each of the studied buildings with high energy efficiency class. Measures to increase energy efficiency were confirmed to decrease the air exchange rate and accumulation of high radon concentrations indoors. Despite of recommendations to use mechanical ventilation with heat recovery as the main scenario for reducing elevated radon concentrations in energy-efficient buildings, the use of such systems did not show an obvious advantage. In real situation, mechanical ventilation system is not used properly both in the automatic and manual mode, which does not give an obvious advantage over natural ventilation in the climate of the Middle Urals in Ekaterinburg. Significant number of buildings with a high class of energy efficiency and built using modern space-planning decisions contributes to an increase in the average radon concentration. Such situation contradicts to “as low as reasonable achievable” principle of the radiation protection.

  16. Evaluation of the uniformity of concentration of radon in a radon chamber.

    Science.gov (United States)

    Xiongjie, Zhang; Ye, Zhang; Yang, Liu; Bin, Tang

    2016-04-01

    In order to solve the problem that the evaluation results of the uniformity of concentration of radon in a radon chamber via various methods were difficult to compare, according to its statistical properties, a mathematical model was built to analyze the uniformity of concentration of radon; an evaluation method for the overall uniformity of concentration of radon was proposed on the basis of single-factor multi-group ANOVA, and a detection method for nonuniform points in a radon chamber was proposed on the basis of single-factor two-group t-test; an evaluation process of the uniformity of concentration of radon in a radon chamber was established. The proposed method was applied to evaluate the HD-6 small and medium-sized radon chambers and achieved good results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. General Services Administration Childcare Radon Results in the Federal Radon Action Plan

    Science.gov (United States)

    GSA made a commitment to support the FRAP’s radon risk goal by sampling for radon in its childcare centers. Over the past two years, the sampling has been performed by independent consultants using recommended standard methods and protocols.

  18. [Portable Epileptic Seizure Monitoring Intelligent System Based on Android System].

    Science.gov (United States)

    Liang, Zhenhu; Wu, Shufeng; Yang, Chunlin; Jiang, Zhenzhou; Yu, Tao; Lu, Chengbiao; Li, Xiaoli

    2016-02-01

    The clinical electroencephalogram (EEG) monitoring systems based on personal computer system can not meet the requirements of portability and home usage. The epilepsy patients have to be monitored in hospital for an extended period of time, which imposes a heavy burden on hospitals. In the present study, we designed a portable 16-lead networked monitoring system based on the Android smart phone. The system uses some technologies including the active electrode, the WiFi wireless transmission, the multi-scale permutation entropy (MPE) algorithm, the back-propagation (BP) neural network algorithm, etc. Moreover, the software of Android mobile application can realize the processing and analysis of EEG data, the display of EEG waveform and the alarm of epileptic seizure. The system has been tested on the mobile phones with Android 2. 3 operating system or higher version and the results showed that this software ran accurately and steadily in the detection of epileptic seizure. In conclusion, this paper provides a portable and reliable solution for epileptic seizure monitoring in clinical and home applications.

  19. Embedded multiparametric system for volcano monitoring

    Science.gov (United States)

    Moure, David; Torres, Pedro A.; Meletlidis, Stavros; Lopez, Carmen; José Blanco, María

    2014-05-01

    A low cost and low power consumption multiparametric system designed for volcano monitoring is presented. Once tested with various sensors, at present it is installed in two locations in Tenerife, Canary Islands, acquiring and transmitting data in real time. The system is based on a commercial board (Raspberry Pi®, RPi®) that uses an embedded ARMTM processor with a Debian (Wheezy-Raspbian) Linux Operating System. This configuration permits different standard communication systems between devices as USB and ETHERNET, and also communication with integrated circuits is possible. The whole system includes this platform and self-developed hardware and software. Analog signals are acquired at an expansion board with an ADC converter with three 16 bits channels. This board, which is powered directly from the RPi®, provides timing to the sampling data using a Real Time Clock (RTC). Two serial protocols (I2C and SPI) are responsible for communications. Due to the influence of atmospheric phenomena on the volcano monitoring data, the system is complemented by a self-developed meteorological station based on ArduinoCC and low cost commercial sensors (atmospheric pressure, humidity and rainfall). It is powered with the RPi® and it uses a serial protocol for communications. Self-developed software run under Linux OS and handles configuration, signal acquisition, data storage (USB storage or SD card) and data transmission (FTP, web server). Remote configuration, data plotting and downloading is available through a web interface tool. Nowadays, the system is used for gravimetric and oceanic tides data acquisition in Tenerife and soon it will be applied for clinometric data.

  20. Time variation of radon daughters concentration in snowfall.

    Science.gov (United States)

    Nishikawa, T; Aoki, M; Okabe, S

    1984-05-01

    Time variation of radon daughters concentration in snowfall was measured continuously. The relations of radon daughters concentration in snowfall to the precipitation and to atmospheric radon daughters concentration were investigated. It has become clear that when precipitation is small, radon daughters concentration in snowfall is distributed in a wide range, and that the quantity of radon daughters brought to ground surface by snowfall is proportional to precipitation. Washout effect of the snowfall on atmospheric radon daughters was also investigated.

  1. Smart Garbage Monitoring System for Waste Management

    Directory of Open Access Journals (Sweden)

    Mohd Yusof Norfadzlia

    2017-01-01

    Full Text Available Piles of rubbish are one of the major problems faced by most people in Malaysia, especially those who live in flats, as the number of bins is limited and shared among all residents. It may cause pollutions, which may lead to sanitary issues and diseases. This project presents the development of a smart garbage monitoring system in order to measure waste level in the garbage bin in real-time and to alert the municipality, in particular cases, via SMS. The proposed system is consisted by the ultrasonic sensor to measure the waste level, the GSM module to send the SMS, and an Arduino Uno which controls the system operation. It supposes to generate and send the warning messages to the municipality via SMS when the waste bin is full or almost full, so the garbage can be collected immediately. Furthermore, it is expected to contribute to improving the efficiency of the solid waste disposal management.

  2. Process monitoring using ultrasonic sensor systems.

    Science.gov (United States)

    Henning, Bernd; Rautenberg, Jens

    2006-12-22

    Continuous in-line measurement of substance concentration in liquid mixtures is valuable in improving industrial processes in terms of material properties, energy efficiency and process safety. Ultrasonic sensor systems meet the practical requirements of a chemical sensor quite well. Currently ultrasonic sensor systems are widely used as acoustic chemical sensors to measure concentration of selected substances or to monitor the course of polymerisation, crystallisation or fermentation processes. Useable acoustic properties for the characterisation of liquid mixtures are sound velocity, sound absorption and acoustic impedance. This contribution will give a short overview of the state of the art and several trends for the use of ultrasonic sensor systems in process applications. Novel investigations show the very promising possibility to analyse liquid multi-phase mixtures like suspensions, emulsions and dispersions.

  3. Development of a predictive methodology for identifying high radon exhalation potential areas; Mise au point d'une methodologie predictive des zones a fort potentiel d'exhalation du radon

    Energy Technology Data Exchange (ETDEWEB)

    Ielsch, G

    2001-07-01

    Radon 222 is a radioactive natural gas originating from the decay of radium 226 which itself originates from the decay of uranium 23 8 naturally present in rocks and soil. Inhalation of radon gas and its decay products is a potential health risk for man. Radon can accumulate in confined environments such as buildings, and is responsible for one third of the total radiological exposure of the general public to radiation. The problem of how to manage this risk then arises. The main difficulty encountered is due to the large variability of exposure to radon across the country. A prediction needs to be made of areas with the highest density of buildings with high radon levels. Exposure to radon varies depending on the degree of confinement of the habitat, the lifestyle of the occupants and particularly emission of radon from the surface of the soil on which the building is built. The purpose of this thesis is to elaborate a methodology for determining areas presenting a high potential for radon exhalation at the surface of the soil. The methodology adopted is based on quantification of radon exhalation at the surface, starting from a precise characterization of the main local geological and pedological parameters that control the radon source and its transport to the ground/atmosphere interface. The methodology proposed is innovative in that it combines a cartographic analysis, parameters integrated into a Geographic Information system, and a simplified model for vertical transport of radon by diffusion through pores in the soil. This methodology has been validated on two typical areas, in different geological contexts, and gives forecasts that generally agree with field observations. This makes it possible to identify areas with a high exhalation potential within a range of a few square kilometers. (author)

  4. 9th Saxonian radon day. 11th meeting on radon safe structural engineering; 9. Saechsischer Radontag. 11. Tagung radonsicheres Bauen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-07-01

    The proceedings of the meeting in radon-safe structural engineering covers contributions on the following issues: implementation of the EU standards, radon protection in underground cavities, radon protection at working places, reports on experiences.

  5. Monitoring the LHCb data quality system

    CERN Multimedia

    Baranov, Alexander

    2016-01-01

    Monitoring the quality of the data, DQM, is crucial in a high-energy physics experiment to ensure the correct functioning of the apparatus during the data taking. DQM at LHCb is carried out in two phase. The first one is performed on-site, in real time, using unprocessed data directly from the LHCb detector, while the second, also performed on-site, requires the reconstruction of the data selected by the LHCb trigger system and occurs with some delay. For the Run II data taking the LHCb collaboration has re-engineered the DQM protocols and the DQM graphical interface, moving the latter to a web-based monitoring system, called Monet, thus allowing researchers to perform the second phase off-site. In order to support the operator's task, Monet is also equipped with an automated, fully configurable, alarm system, thus allowing its use not only for DQM purposes, but also to track and assess the quality of LHCb software and simulation.

  6. Automatic outdoor monitoring system for photovoltaic panels.

    Science.gov (United States)

    Stefancich, Marco; Simpson, Lin; Chiesa, Matteo

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  7. Prometheus: a next-generation monitoring system

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Prometheus is an open eco-system that provides an end-to-end approach to infrastructure and application monitoring. It covers all levels beginning with easy instrumentation based on a flexible, multi-dimensional data model. The Prometheus server itself collects and stores time series while trying to maintain operational simplicity while being adaptable to varying scales and layouts of infrastructure. By integrating with a wide range of service discovery systems, it always stays in sync with the world it is monitoring. The powerful query language allows us to ask complex questions and can be applied seamlessly between ad-hoc investigation and static dashboarding. It is also directly applied in the eco-system's alerting layer, which favors a time-series based over and event driven approach. In this talk we will look at all aspects of Prometheus from the high-level philosophy behind its design to its practical concerns of implementation and operation. About the speaker Fabian Reinartz is a software eng...

  8. Automatic outdoor monitoring system for photovoltaic panels

    Energy Technology Data Exchange (ETDEWEB)

    Stefancich, Marco [Consiglio Nazionale delle Ricerce, Istituto dei Materiali per l’Elettronica ed il Magnetismo (CNR-IMEM), Parco Area delle Scienze 37/A, 43124 Parma, Italy; Simpson, Lin [National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA; Chiesa, Matteo [Masdar Institute of Science and Technology, P.O. Box 54224, Masdar City, Abu Dhabi, United Arab Emirates

    2016-05-01

    Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. The instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

  9. The Medusa Sea Floor Monitoring System

    Science.gov (United States)

    Flynn, F. T.; Schultz, A.; Gupta, M.; Powers, L.; Klinkhammer, G.

    2004-12-01

    The Medusa Sea Floor Monitoring System (MSMS) is a technology development project that is designed to enable fundamental research into understanding the potential for and limits to chemolithoautotrophic life. This is life within which inorganic carbon is converted to organic carbon and where only inorganic compounds serve as electron acceptors and electron donors. Such life forms are postulated to be capable of surviving in a Europan ocean. If we can prove that such life forms exist on Earth it would provide credence to the hypothesis that they might exist on other planets or moons in our Solar System. It has been hypothesized that one environment which might foster such life is associated with sub-seafloor hydrothermal vent structures. The goal of the MSMS project is to develop an instrument capable of testing this hypothesis. The MSMS instrument is an evolution of a sea floor monitoring system developed by Dr. Adam Schultz. Its design is the result of many generations of hardware and dive programs. Medusa provides the capability to measure and sample effluent and influent sea floor hydraulic flows associated with hydrothermal vent structures, active sea mounds, and sea floor bore holes. Through this proposal we are developing the next generation Medusa system and initiating the integration of several select chemical and biological sensors into the Medusa backbone. These sensors are an in situ flow-through spectral chemistry system, a cavity ringdown 12C/13C system, and an intrinsic fluorescence instrument. der way. This instrument can be used to target and discriminate between biological samples for automated sample collection

  10. Underwater Animal Monitoring Magnetic Sensor System

    KAUST Repository

    Kaidarova, Altynay

    2017-10-01

    Obtaining new insights into the behavior of free-living marine organisms is fundamental for conservation efforts and anticipating the impact of climate change on marine ecosystems. Despite the recent advances in biotelemetry, collecting physiological and behavioral parameters of underwater free-living animals remains technically challenging. In this thesis, we develop the first magnetic underwater animal monitoring system that utilizes Tunnel magnetoresistance (TMR) sensors, the most sensitive solid-state sensors today, coupled with flexible magnetic composites. The TMR sensors are composed of CoFeB free layers and MgO tunnel barriers, patterned using standard optical lithography and ion milling procedures. The short and long-term stability of the TMR sensors has been studied using statistical and Allan deviation analysis. Instrumentation noise has been reduced using optimized electrical interconnection schemes. We also develop flexible NdFeB-PDMS composite magnets optimized for applications in corrosive marine environments, and which can be attached to marine animals. The magnetic and mechanical properties are studied for different NdFeB powder concentrations and the performance of the magnetic composites for different exposure times to sea water is systematically investigated. Without protective layer, the composite magnets loose more than 50% of their magnetization after 51 days in seawater. The durability of the composite magnets can be considerably improved by using polymer coatings which are protecting the composite magnet, whereby Parylene C is found to be the most effective solution, providing simultaneously corrosion resistance, flexibility, and enhanced biocompatibility. A Parylene C film of 2μm thickness provides the sufficient protection of the magnetic composite in corrosive aqueous environments for more than 70 days. For the high level performance of the system, the theoretically optimal position of the composite magnets with respect to the sensing

  11. Locomotive monitoring system using wireless sensor networks

    CSIR Research Space (South Africa)

    Croucamp, PL

    2014-07-01

    Full Text Available Conference on Industrial Informatics (INDIN), 27-30 July 2014 Locomotive monitoring system using wireless sensor networks P. L. Croucamp1, S. Rimer1 and C. Kruger2 1Department of Electrical and Electronic Engineering University of Johannesburg... Johannesburg, South Africa Email: suvendic@uj.ac.za 2Advanced Sensor Networks, Meraka. CSIR Pretoria, South Africa Email: ckruger1@csir.co.za Abstract Theft of cables used for powering a locomotive not only stops the train from functioning but also...

  12. Determination of concentration of radon, volatile organic compounds (VOC) and water chemistry in springs near to Popocatepetl volcano; Determinacion de la concentracion de radon, VOCs y Quimica del agua en manantiales cercanos al volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez M, B.E.; Cisniega, G. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Valdes, C.; Armienta, M.A.; Mena, M. [Instituto de Geofisica, UNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    Popocatepetl volcano is a high-risk active volcano in Central Mexico where the highest population density in the country is settled. Radon in the soil and groundwater together with water chemistry from samples of nearby springs is analysed as a function of the 2002-2003 volcanic activity. Soil radon indicated fluctuations related both the meteorological parameters and sporadic explosive events. Groundwater radon showed essentially differences in concentration due to the specific characteristics of the studied springs. Water chemistry showed stability along the monitoring period indicating also differences between springs. No anthropogenic pollution from volatile organic compounds was observed. (Author)

  13. airborne data analysis/monitor system

    Science.gov (United States)

    Stephison, D. B.

    1981-01-01

    An Airborne Data Analysis/Monitor System (ADAMS), a ROLM 1666 computer based system installed onboard test airplanes used during experimental testing is evaluated. In addition to the 1666 computer, the ADAMS hardware includes a DDC System 90 fixed head disk and a Miltape DD400 floppy disk. Boeing designed a DMA interface to the data acquisition system and an intelligent terminal to reduce system overhead and simplify operator commands. The ADAMS software includes RMX/RTOS and both ROLM FORTRAN and assembly language are used. The ADAMS provides real time displays that enable onboard test engineers to make rapid decisions about test conduct thus reducing the cost and time required to certify new model airplanes, and improved the quality of data derived from the test, leading to more rapid development of improvements resulting in quieter, safer, and more efficient airplanes. The availability of airborne data processing removes most of the weather and geographical restrictions imposed by telemetered flight test data systems. A data base is maintained to describe the airplane, the data acquisition system, the type of testing, and the conditions under which the test is performed.

  14. The ORNL Indoor Air Quality Study: Re-cap, Context, and Assessment on Radon

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, Bruce Edward [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rose, Erin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ternes, Mark P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-01

    As part of the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program that was led by Oak Ridge National Laboratory (ORNL), an assessment of the impacts of weatherization on indoor air quality (IAQ) was conducted. This assessment included nearly 500 treatment and control homes across the country. Homes were monitored for carbon monoxide, radon, formaldehyde, temperature and humidity pre- and post-weatherization. This report focuses on the topic of radon and addresses issues not thoroughly discussed in the original IAQ report. The size, scope and rigor of the radon component of the IAQ study are compared to previous studies that assessed the impacts of weatherization on indoor radon levels. It is found that the ORNL study is by far the most extensive study conducted to date, though the ORNL results are consistent with the findings of the other studies. However, the study does have limitations related to its reliance on short-term measurements of radon and inability to attribute changes in radon levels in homes post-weatherization to specific weatherization measures individually or in combination.

  15. Search for radon sources in buildings--kindergartens.

    Science.gov (United States)

    Vaupotic, J

    2002-01-01

    In ten high radon level kindergartens, radon sources were sought by applying a combination of several radon measuring techniques: etched track detectors to obtain average indoor air radon concentration, continuous devices to record radon concentration and see its diurnal variation, and alpha scintillation cells to determine radon concentration in the air entering a room from cracks, holes and sinks in the floor and from under-floor channels. In three cases, a strong local radon source was identified while, in the others, the bad quality of the basic concrete slab was responsible for the high indoor radon concentration.

  16. The radon: evaluation and risk management; Le radon: evaluation et gestion du risque

    Energy Technology Data Exchange (ETDEWEB)

    Lacoste, A.C. [Direction Generale de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Masse, R. [Academie des Technologies, 75 - Paris (France); Aurengo, A. [Hopital Pitie-Salpetriere, Service de Medecine Nucleaire, 75 - Paris (France); Erich Wichmann, H. [Neuberberg Munich Univ. (Germany); Timarche, M.; Laurier, D.; Robe, M.Ch. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92 - Clamart (France); Baubron, J.C.; Bonijoly, D. [BRGM, 75 - Paris (France); Collignan, B. [Centre Scientifique et Technique du Batiment, (CSTB), 75 - Paris (France); Berrier, H. [Direction Gle de l' Urbanisme de l' Habitat et de la Construction, 75 - Paris (France); Jaouen, J. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Vienne (France); Caamano, D. [Direction Departementale des Affaires Sanitaires et Sociales de l' Essonne, 91 (France); Guiot, F. [Direction Departementale des Affaires Sanitaires et Sociales de la Haute-Marne (France); Grall, B. [Direction Departementale des Affaires Sanitaires et Sociales de Bretagne (France); Frutos Vasquez, B.; Olaya Adan, M. [Istituto de Ciencias de la Construction (Italy); Garcia Cadierno, J.P.; Martin Matarranz, J.L.; Serrano Renedo, J.; Suarez Mahou, E. [Consejo de Seguridad Nuclear, Madrid (Spain); Fernandez, J.A. [ENUSA Industrias Avanzadas (Spain); Mjones, L.; Pirard, P. [Institut de veille sanitaire, 94415 - Saint-Maurice (France); Godet, J.L.; Rougy, Ch. [Direction Gle de la Surete Nucleaire et de la Radioprotection, 75 - Paris (France)

    2003-06-15

    The radon exposure constitutes for the French population the first cause of natural irradiation among the different natural sources of irradiation. It is possible to have a significant action on it, either by making draught proof in order to avoid to radon to get inside houses, either by ventilating in order to dispel the radon and improve air quality. (N.C.)

  17. Unexpected Daily Peaks in a Laboratory Simulation Experiment of Radon Signals

    Science.gov (United States)

    Bezaly, Orr Rose; Steinitz, Gideon; Israelevich, Peter; Kotlarsky, Peter; Piatibratova, Oksana; Malik, Uri; Asperil, Tal; Marco, Shmuel

    2017-04-01

    Radon is a noble radioactive gas of special interest in earth sciences due to both its unique chemical and physical properties and its natural abundance. The most stable isotope of radon, 222Rn, has a half-life of 3.823 days and is the only gas-phase atom in the 238U decay series. Radon could be considered as a possible tracer for tectonic and volcanic processes, yet the physical mechanisms that influence radon emanation from rock and transport are unclear. Our team strives to observe and analyse radon signals in monitored environments. Simulation of radon signals and investigation of their characteristics in laboratory experiments are conducted using radon in an enclosed chamber, termed "Enhanced Confined Mode" (ECM). An ECM experiment will be described; its arrangement comprises of two 222Rn sources of activity ˜105Bq each. The sources are connected in parallel via tube to a horizontal stainless steel cylinder (˜570cm3) that contains air at atmospheric pressure. Direct count rate measurements were performed using a NaI (2x2") gamma-ray scintillation detector aligned along the cylinder's axis, at one minute resolution, for over 60 days. Radon is supplied into the ECM chamber by diffusion and it disintegrates as it undergoes radioactive decay. A priori, a steady state of diffusion and radioactive decay rates is expected. However, our results show evident deviations from this expected steady state, namely fluctuations that are significant relative to the uncertainty in measurements. Predominant daily peaks characterise the data. Signal processing and analysis of these daily peaks will be presented.

  18. Are seasonal correction factors useful in assessing the health risk from domestic radon

    Energy Technology Data Exchange (ETDEWEB)

    Denman, A.R.; Groves-Kirkby, C.J. [Northampton General Hospital, Medical Physics Dept. (United Kingdom); Crockett, R.G.M.; Phillips, P.S.; Woolridge, A.C. [Northampton Univ., School of Applied Sciences (United Kingdom); Gillmore, G.K. [Bradford Univ., School of Archaeological, Geographical and Environmental Sciences (United Kingdom)

    2006-07-01

    Following an intensive survey of domestic radon levels in the UK, the former National Radiological Protection Board (N.R.P.B.), now the Radiation Protection Division of the Health Protection Agency (H.P.A.-R.P.D.) established a measurement protocol and promulgated a set of Seasonal Correction Factors (S.C.F.) applicable to the United Kingdom as a whole. Radon levels are assumed to exhibit systematic repeatable annual variation, generally higher in winter than in summer, and the S.C.F. comprise numerical multipliers which convert a one-month oree-month radon measurement, commencing in any month of the year, to an effective annual mean radon concentration. In a recent project to assess the utility of short-term exposures in quantifying domestic radon levels, radon variability in a set of 34 houses on common radon-rich geology was found to depart significantly from that predicted by the H.P.A.-R.P.D. seasonal correction factors, with year-end discontinuities at both 1-month and 3- month measurement resolutions. Following this study, monitoring with electrets was continued in four properties, with weekly radon concentration data now available for a total duration of three years. Analysis of this data has permitted the derivation of reliable local seasonal correction factors. Overall, these are significantly lower than those recommended by H.P.A.-R.P.D., but are comparable with other results from the UK and from abroad, particularly those that recognise geological diversity and are consequently prepared on a regional rather than a national basis. The discussion calls into question the validity of using nationally aggregated factors, especially for shorter exposures. (authors)

  19. Investigation of radon level in air and tap water of workplaces at Thailand Institute of Nuclear Technology, Thailand

    Science.gov (United States)

    Sola, P.; Youngchuay, U.; Kongsri, S.; Kongtana, A.

    2017-06-01

    Thailand Institute of Nuclear Technology (TINT) has continuously monitored radiation exposure and radionuclide in workplaces specifically radon gas to estimate effective dose for workers. Radon exposure is the second leading cause of lung cancer in the world. In this study, radon in air and tap water at building no. 3, 7, 8, 9 and 18 on Ongkharak site of TINT have been measured for 5 years from 2012 to 2016. Radon level in air and tap water were investigated on 83 stations (workplaces) and 54 samples, respectively. Radon concentrations in air and tap water were measured by using the pulsed ionization chamber (ATMOS 12 DPX). Indoor radon concentrations in air were in the range of 12-138 Bq.m-3 with an average value of 30.13±17.05 Bq.m-3. Radon concentrations in tap water were in the range of 0.10 to 2.89 Bq.l-1 with an average value of 0.51±0.55 Bq.l-1. The results of radon concentrations at TINT were below the US Environmental Protection Agency (US EPA) safety limit of 148 Bq.m-3 and 150 Bq.l-1, for, air and tap water, respectively. The average effective dose for TINT’s workers due to indoor radon exposure was approximately 0.20±0.11 mSv.y-1. The value is 100 times less than the annual dose limit for limit occupational radiation worker defined by the International Commission on Radiological Protection (ICRP). As a result, the TINT’s workplaces are radiologically safe from radon content in air and tap water.

  20. 30 CFR 27.21 - Methane-monitoring system.

    Science.gov (United States)

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Construction and Design Requirements § 27.21 Methane-monitoring system. (a) A methane-monitoring system shall be so designed that any machine or equipment, which.... (d) An enclosure shall be equipped with a lock, seal, or acceptable equivalent when MSHA deems such...

  1. A perspective on risks from radon

    Energy Technology Data Exchange (ETDEWEB)

    Higson, D. J., E-mail: higsond@bigpond.net.a [Australasian Radiation Protection Society, PO Box 7108, Upper Ferntree Gully, Victoria 3156 (Australia)

    2010-10-15

    In its Statement on Radon (November 2009), the International Commission on Radiological Protection (ICRP) has reduced the upper reference level for radon gas in dwellings to 300 Bq m{sup -3}. The recommended level for workplaces is 1000 Bq m{sup -3}. A risk coefficient of 8 x 10{sup -10} per Bq h m{sup -3} is recommended without reference to smoking habits. On the basis of these figures: 1) The estimated risk of fatal cancer from exposure to radon at home and at work could be greater than the observed risk of accidental death from travelling by car, which would be surprising if true. 2) The estimated risk of lung cancer from radon could be greater than the observed risk of lung cancer from all causes, which is actually known to be dominated by smoking. The author is not aware of any direct evidence of risks from inhaling radon in Australian dwellings, 99% of which have radon levels below 50 Bq m{sup -3}. Evidence available from other countries shows that: 1) The effects of radon in the incidences of lung cancer are uncertain at levels less then about 50-100 Bq m{sup -3}. 2) The estimation of risks at levels below 200 Bq m{sup -3} depends on extrapolation from risks observed at higher levels. 3) Risks to non-smokers from radon are 25 times less than risks to smokers. Its concluded that the ICRP Statement on Radon and radon policies in the US and UK have the potential to cause unwarranted concern. Some people may be made to feel they need to spend money modifying their homes and workplaces to protect occupants from exposure to radon when there is no compelling reason to show that this is necessary. The vast majority of non-smokers do not need to be protected from radon. (Author)

  2. Beam Position Monitor System for PEP II

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Stephen R.; Aiello, G.Roberto; Hendrickson, Linda J.; Johnson, Ronald G.; Mills, Mark R.; Olsen, Jeff J.; /SLAC

    2011-09-12

    We describe the beam position monitor system built for PEP-II, the B-factory at SLAC. The system reports beam position for bunches of between 5 x 10{sup 8} and 8 x 10{sup 10} electron charges, either singly or as continuous streams of bunches every 4.2 ns. Resolution at full charge is to be better than 10 microns in a single turn. Higher resolution is available via on-board multi-turn averaging. The position signal is processed in a 20 MHz bandwidth around 952 MHz. This bandwidth, rather broader than that typical of RF position monitors, allows good resolution for low charge single bunches. Additional novel features include stringent control of return losses in order to minimize cross-talk between nearby bunches which may contain very different charges. The digitizing electronics is multiplexed between the two PEP-II storage rings. Design, construction, and installation experience, as well as first results with beam are presented.

  3. MST radar transmitter control and monitor system

    Science.gov (United States)

    Brosnahan, J. W.

    1983-01-01

    A generalized transmitter control and monitor card was developed using the Intel 8031 (8051 family) microprocessor. The design was generalized so that this card can be utilized for virtually any control application with only firmware changes. The block diagram appears in Figure 2. The card provides for local control using a 16 key keypad (up to 64 keys are supported). The local display is four digits of 7 segment LEDs. The display can indicate the status of all major system parameters and provide voltage readout for the analog signal inputs. The card can be populated with only the chips required for a given application. Fully populated, the card has two RS-232 serial ports for computer communications. It has a total of 48 TTL parallel lines that can define as either inputs or outputs in groups of four. A total of 32 analog inputs with a 0-5 volt range are supported. In addition, a real-time clock/calendar is available if required. A total of 16 k bytes of ROM and 16 k bytes of RAM is available for programming. This card can be the basis of virtually any monitor or control system with appropriate software.

  4. An Alpha spectrometer for measuring radon daughter individual activity concentration; Spettrometro Alfa per la misura delle concentrazioni individuali in attivita' della progenie del radon

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M.; Formignani, M. [ENEA, Div. Protezione dell' Uomo e degli Ecosistemi, Centro Ricerche E. Clementel, Bologna (Italy); Mariotti, F. [Bologna Univ., Bologna (Italy). Dipt. di Fisica

    2001-07-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of {sup 218}Po, {sup 214}Pb and {sup 214}Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated. [Italian] Presso l'Istituto per la Radioprotezione, nell'ambito del programma di valutazione di dose da radon e' stato progettato e realizzato uno spettrometro alfa per il monitoraggio continuo in aria (CAM) della progenie del radon e del toron. Le caratteristiche costruttive dello strumento permettono, tramite l'utilizzo di batterie a diffusione a reti, di determinare l'attivita' individuale della progenie per diverse dimensioni granulometriche in particolare per la frazione attaccata e non al particolato amosferico con un taglio granulometrico di qualche nanometro. E' stato inoltre applicato un metodo spettrometrico a tre conteggi per il calcolo delle concentrazioni individuali della progenie del radon, {sup 218}Po, {sup 214}Pb and {sup 214}Bi, effettuando un conteggio alfa di {sup 218}Po e due conteggi alfa di {sup 214}Po. Tale informazione consentira' una valutazione della dose di radon utilizzando il modello dosimetrico in alternativa a quello epidemiologico.

  5. Does the new EU-BSS improve radon protection in Austria?; Wird durch die neue EU-BSS der Radonschutz in Oesterreich verbessert?

    Energy Technology Data Exchange (ETDEWEB)

    Ringer, W. [AGES, Linz (Austria). Oesterreichische Fachstelle fuer Radon; Haider, W. [Bundesministerium fuer Land- und Forstwirtschaft, Umwelt und Wasserwirtschaft, Wien (Austria). Abt. Strahlenschutz

    2015-07-01

    The new Council Directive 2013/59/EURATOM regarding radiation protection (EU-BSS) contains comprehensive regulations regarding radon protection in dwellings, in public buildings, and at workplaces for the first time. Key elements are the specification of a reference level of maximum 300 Bq/m{sup 3}, the establishment of a national radon action plan, and a more comprehensive regulation of radon protection at workplaces and public buildings. The radon action plan shall contain strategies and measures regarding for example the estimation of the distribution of indoor radon concentrations, the mapping of radon, the radon risk communication strategy, the assignment of responsibilities, and regular reviews of the action plan. The new EU-BSS often requires only the establishment of strategies and the specification of measures, leaving the precise content of the strategies and measures to the member states. This gives the member states flexibility for the implementation of the EU-BSS into national legislation and allows to account for specific national experiences and circumstances. This contribution discusses and evaluates - based on the existing regulations concerning radon protection in Austria - the effectiveness of different new measures and regulations with respect to reducing the radon risk in Austria. Furthermore, their feasibility and practicability in terms of administrative and financial effort will be discussed. Thus, efficient new measures which lead to an improvement of the current radon control system will be identified.

  6. RHIC BEAM LOSS MONITOR SYSTEM INITIAL OPERATION.

    Energy Technology Data Exchange (ETDEWEB)

    WITKOVER,R.L.; MICHNOFF,R.J.; GELLER,J.M.

    1999-03-29

    The RHIC Beam Loss Monitor (BLM) System is designed to prevent beam loss quenching of the superconducting magnets, and acquire loss data. Four hundred ion chambers are located around the rings to detect losses. The required 8-decade range in signal current is compressed using an RC pre- integrator ahead of a low current amplifier. A beam abort may be triggered if fast or slow losses exceed programmable threshold levels. A micro-controller based VME module sets references and gains and reads trip status for up to 64 channels. Results obtained with the detectors in the RHIC Sextant Test and the prototype electronics in the AGS-to-RHIC (AtR) transfer line are presented along with the present status of the system.

  7. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Boumediene, Djamel Eddine; The ATLAS collaboration

    2017-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). PMT signals are then digitized at 40 MHz and stored on detector and are only transferred off detector once the first level trigger acceptance has been confirmed. The readout is segmented into about 5000 cells (longitudinally and transversally), each of them being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of each part of the readout chain, a set of calibration systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements and an integrator b...

  8. Radon in indoor air of primary schools: determinant factors, their variability and effective dose.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João; Moreira, André; de Oliveira Fernandes, Eduardo; Pereira, Alcides

    2016-04-01

    Radon is a radioactive gas, abundant in granitic areas, such as in the city of Porto at the north-east of Portugal. This gas is a recognized carcinogenic agent, being appointed by the World Health Organization as the leading cause of lung cancer after smoking. The aim of this preliminary survey was to determine indoor radon concentrations in public primary schools, to analyse the main factors influencing their indoor concentration levels and to estimate the effective dose in students and teachers in primary schools. Radon concentrations were measured in 45 classrooms from 13 public primary schools located in Porto, using CR-39 passive radon detectors for about 2-month period. In all schools, radon concentrations ranged from 56 to 889 Bq/m(3) (mean = 197 Bq/m(3)). The results showed that the limit of 100 Bq/m(3) established by WHO IAQ guidelines was exceeded in 92 % of the measurements, as well as 8 % of the measurements exceeded the limit of 400 Bq/m(3) established by the national legislation. Moreover, the mean annual effective dose was calculated as 1.25 mSv/y (ranging between 0.58 and 3.07 mSv/y), which is below the action level (3-10 mSv). The considerable variability of radon concentration observed between and within floors indicates a need to monitor concentrations in several rooms for each floor. A single radon detector for each room can be used, provided that the measurement error is considerably lower than variability of radon concentration between rooms. The results of the present survey will provide useful baseline data for adopting safety measures and dealing effectively with radiation emergencies. In particular, radon remediation techniques should be used in buildings located in the highest radon risk areas of Portugal. The results obtained in the current study concerning radon levels and their variations will be useful to optimize the design of future research surveys.

  9. Indoor radon seasonal variability at different floors of buildings

    Energy Technology Data Exchange (ETDEWEB)

    De Francesco, S. [Department of Environmental Sciences, Second University of Naples, Via Vivaldi, 43, 81100 Caserta (Italy); Tommasone, F. Pascale [Office of Civil Protection, Meteorology, Climatology and Natural Hazards, Piazza Municipio, 81051 Pietramelara, Caserta (Italy); Cuoco, E. [Department of Environmental Sciences, Second University of Naples, Via Vivaldi, 43, 81100 Caserta (Italy); Tedesco, D., E-mail: dtedesco@unina.i [Department of Environmental Sciences, Second University of Naples, Via Vivaldi, 43, 81100 Caserta (Italy); C.N.R. (Italian Council for Research), Institute of Environmental Geology and Geological Engineering, Piazzale Aldo Moro, 00100 Roma (Italy)

    2010-09-15

    Indoor radon concentrations have been measured with the {alpha} track etch integrated method in public buildings in the town of Pietramelara, north-western Campania, Southern Italy. In particular, our measurements were part of an environmental monitoring program originally aimed at assessing the range of seasonal fluctuations in indoor radon concentrations, at various floors of the studied buildings. However, subsequent analysis of the data and its comparison with the meteorological data recorded in the same period has shown an unexpected pattern at the different floors. In this report we present data suggesting that, besides the well-known medium and longterm periodicity, there could also be a differentiation in major meteorological controlling factors at the different floors of the buildings, a fact that does not appear to have been reported previously. While the lower floors proved to be markedly affected by rainfall, for the upper floors, instead, a different behaviour has been detected, which could possibly be related to global solar radiation.

  10. Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

    Science.gov (United States)

    Iverson, David L. (Inventor)

    2008-01-01

    The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

  11. Performance improvement clarification for refrigeration system using active system monitoring

    DEFF Research Database (Denmark)

    Green, Torben; Niemann, Hans Henrik; Izadi-Zamanabadi, Roozbeh

    2011-01-01

    This paper addresses the problem of determining whether a refrigeration plant has the possibility of delivering a better performance of the operation. The controllers are wellknown but detailed knowledge about the underlying dynamics of the refrigeration plant is not available. Thus, the question...... is if it is possible to achieve a better performance by changing the controller parameter. An approach to active system monitoring, based on active fault diagnosis techniques, is employed in order to evaluate changes in the system performance under operation....

  12. Radon in water of Shu river valley

    Directory of Open Access Journals (Sweden)

    Yelena Kuyanova

    2012-03-01

    Full Text Available The values of radon and its daughter products in water of Shu River valley have been received, using liquid scintillation spectrometry. The radon concentration naturally increases in investigated water samples downstream the Shu River, reaching the maximum value in the Tashutkolsky basin. The radon and its daughter products in a human body of 15 % are in soft tissues have been calculated by a mathematical modeling method. The annual dose from radon and its daughter products calculated by a mathematical modeling method received by the residents living in Shu river valley is 0,03 mSv/year.

  13. Low-Cost Radon Reduction Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Rose, William B. [Partnership for Advanced Residential Retrofit, Champaign, IL (United States); Francisco, Paul W. [Partnership for Advanced Residential Retrofit, Champaign, IL (United States); Merrin, Zachary [Partnership for Advanced Residential Retrofit, Champaign, IL (United States)

    2015-09-01

    The aim of the research was to conduct a primary scoping study on the impact of air sealing between the foundation and the living space on radon transport reduction across the foundation-living space floor assembly. Fifteen homes in the Champaign, Illinois area participated in the study. These homes were instrumented for hourly continuous radon measurements and simultaneous temperature and humidity the foundation was improved. However, this improved isolation did not lead to significant reductions in radon concentration in the living space. Other factors such as outdoor temperature were shown to have an impact on radon concentration.

  14. Interpreting the radon transform using Prolog

    Science.gov (United States)

    Batchelor, Bruce G.

    1992-03-01

    The Radon transform is an important method for identifying linear features in a digital image. However, the images which the Radon transform generates are complex and require intelligent interpretation, to identify lines in the input image correctly. This article describes how the images can be pre-processed to make the spots in the Radon transform image more easily identified and describes Prolog programs which can recognize constellations of points in the Radon transform image and thereby identify geometric figures within the input image.

  15. Indirect Tire Monitoring System - Machine Learning Approach

    Science.gov (United States)

    Svensson, O.; Thelin, S.; Byttner, S.; Fan, Y.

    2017-10-01

    The heavy vehicle industry has today no requirement to provide a tire pressure monitoring system by law. This has created issues surrounding unknown tire pressure and thread depth during active service. There is also no standardization for these kind of systems which means that different manufacturers and third party solutions work after their own principles and it can be hard to know what works for a given vehicle type. The objective is to create an indirect tire monitoring system that can generalize a method that detect both incorrect tire pressure and thread depth for different type of vehicles within a fleet without the need for additional physical sensors or vehicle specific parameters. The existing sensors that are connected communicate through CAN and are interpreted by the Drivec Bridge hardware that exist in the fleet. By using supervised machine learning a classifier was created for each axle where the main focus was the front axle which had the most issues. The classifier will classify the vehicles tires condition and will be implemented in Drivecs cloud service where it will receive its data. The resulting classifier is a random forest implemented in Python. The result from the front axle with a data set consisting of 9767 samples of buses with correct tire condition and 1909 samples of buses with incorrect tire condition it has an accuracy of 90.54% (0.96%). The data sets are created from 34 unique measurements from buses between January and May 2017. This classifier has been exported and is used inside a Node.js module created for Drivecs cloud service which is the result of the whole implementation. The developed solution is called Indirect Tire Monitoring System (ITMS) and is seen as a process. This process will predict bad classes in the cloud which will lead to warnings. The warnings are defined as incidents. They contain only the information needed and the bandwidth of the incidents are also controlled so incidents are created within an

  16. Novel OSNR Monitoring Technique in Dense WDM Systems using Inherently Generated CW Monitoring Channels

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal

    2007-01-01

    We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing.......We present a simple, yet effective OSNR monitoring technique based on an inherent effect in the optical modulator. Highly accurate OSNR monitoring is demonstrated in a 40 Gb/s dense WDM system with 50 GHz channel spacing....

  17. Condition monitoring system of wind turbine generators

    Science.gov (United States)

    Abdusamad, Khaled B.

    The development and implementation of the condition monitoring systems (CMS) play a significant role in overcoming the number of failures in the wind turbine generators that result from the harsh operation conditions, such as over temperature, particularly when turbines are deployed offshore. In order to increase the reliability of the wind energy industry, monitoring the operation conditions of wind generators is essential to detect the immediate faults rapidly and perform appropriate preventative maintenance. CMS helps to avoid failures, decrease the potential shutdowns while running, reduce the maintenance and operation costs and maintain wind turbines protected. The knowledge of wind turbine generators' faults, such as stator and rotor inter-turn faults, is indispensable to perform the condition monitoring accurately, and assist with maintenance decision making. Many techniques are utilized to avoid the occurrence of failures in wind turbine generators. The majority of the previous techniques that are applied to monitor the wind generator conditions are based on electrical and mechanical concepts and theories. An advanced CMS can be implemented by using a variety of different techniques and methods to confirm the validity of the obtained electrical and mechanical condition monitoring algorithms. This thesis is focused on applying CMS on wind generators due to high temperature by contributing the statistical, thermal, mathematical, and reliability analyses, and mechanical concepts with the electrical methodology, instead of analyzing the electrical signal and frequencies trends only. The newly developed algorithms can be compared with previous condition monitoring methods, which use the electrical approach in order to establish their advantages and limitations. For example, the hazard reliability techniques of wind generators based on CMS are applied to develop a proper maintenance strategy, which aims to extend the system life-time and reduce the potential

  18. Optical performance monitoring in coherent optical OFDM systems.

    Science.gov (United States)

    Shieh, William; Tucker, Rodney S; Chen, Wei; Yi, Xingwen; Pendock, Graeme

    2007-01-22

    Optical performance monitoring is an indispensable feature for optical systems and networks. In this paper, we propose the concept of optical performance monitoring through channel estimation by receiver signal processing. We show that in coherent-optical-orthogonal-frequency-division- multiplexed (CO-OFDM) systems, critical optical system parameters including fiber chromatic dispersion, Q value, and optical signal-to-noise ratio (OSNR) can be accurately monitored without resorting to separate monitoring devices.

  19. Molecular Imaging System for Monitoring Tumor Angiogenesis

    Science.gov (United States)

    Aytac, Esra; Burcin Unlu, Mehmet

    2012-02-01

    In cancer, non-invasive imaging techniques that monitor molecular processes associated with the tumor angiogenesis could have a central role in the evaluation of novel antiangiogenic and proangiogenic therapies as well as early detection of the disease. Matrix metalloproteinases (MMP) can serve as specific biological targets for imaging of angiogenesis since expression of MMPs is required for angiogenesis and has been found to be upregulated in every type of human cancer and correlates with stage, invasive, metastatic properties and poor prognosis. However, for most cancers it is still unknown when, where and how MMPs are involved in the tumor angiogenesis [1]. Development of high-resolution, high sensitivity imaging techniques in parallel with the tumor models could prove invaluable for assessing the physical location and the time frame of MMP enzymatic acitivity. The goal of this study is to understand where, when and how MMPs are involved in the tumor angiogenesis. We will accomplish this goal by following two objectives: to develop a high sensitivity, high resolution molecular imaging system, to develop a virtual tumor simulator that can predict the physical location and the time frame of the MMP activity. In order to achieve our objectives, we will first develop a PAM system and develop a mathematical tumor model in which the quantitative data obtained from the PAM can be integrated. So, this work will develop a virtual tumor simulator and a molecular imaging system for monitoring tumor angiogenesis. 1.Kessenbrock, K., V. Plaks, and Z. Werb, MMP:regulators of the tumor microenvironment. Cell, 2010. 141(1)

  20. Radon-222 and gamma ray levels associated with the collection, processing, transmission, and utilization of natural gas.

    Science.gov (United States)

    van Netten, C; Kan, K; Anderson, J; Morley, D

    1998-09-01

    The natural gas industry in British Columbia was investigated for exposure to radioactive contaminants such as radon-222 and lead-210. Radon activity associated with the gathering system ranged from 7-921 Bq/m3. The pipelines to the processing facility contained sludge that had a mean lead-210 activity of 0.494 Bq/g (0.379 standard deviation [SD]) and a mean radium-226 activity of 0.417 (0.398 SD). Within the processing facility the highest levels of radon were associated with propane production streams, and activities as high as 4958 Bq/m3 were found. Equipment handling these streams was also found to have a buildup of scale with lead-210, radium-224, and radium-226 activity. The transmission of salable gas to the consumer indicated a decrease in radon activity that was slightly lower than the estimated radon activity based on the half-life of radon, the distance from the production facility, and the speed of gas transmission. The risk of radon exposure to the worker was deemed well below the guidelines and would be controlled more than adequately by means of the occupational standards for the natural gas components. Gamma ray exposure was also well below the occupational standards. Radon exposure to the consumer was virtually nonexistent in the Vancouver region from both natural gas and propane. Although this might not be the case for consumers of propane closer to the production facilities, its contribution is likely to be minimal.

  1. IAA RAS Radio Telescope Monitoring System

    Science.gov (United States)

    Mikhailov, A.; Lavrov, A.

    2007-07-01

    Institute of Applied Astronomy of the Russian Academy of Sciences (IAA RAS) has three identical radio telescopes, the receiving complex of which consists of five two-channel receivers of different bands, six cryogen systems, and additional devices: four local oscillators, phase calibration generators and IF commutator. The design, hardware and data communication protocol are described. The most convenient way to join the devices of the receiving complex into the common monitoring system is to use the interface which allows to connect numerous devices to the data bus. For the purpose of data communication regulation and to exclude conflicts, a data communication protocol has been designed, which operates with complex formatted data sequences. Formation of such sequences requires considerable data processing capability. That is provided by a microcontroller chip in each slave device. The test version of the software for the central computer has been developed in IAA RAS. We are developing the Mark IV FS software extension modules, which will allow us to control the receiving complex of the radio telescope by special SNAP commands from both operator input and schedule files. We are also developing procedures of automatic measurements of SEFD, system noise temperature and other parameters, available both in VLBI and single-dish modes of operation. The system described has been installed on all IAA RAS radio telescopes at "Svetloe", "Zelenchukskaya" and "Badary" observatories. It has proved to be working quite reliably and to show the perfonmance expected.

  2. Wireless Remote Monitoring System for Cultural Heritage

    Directory of Open Access Journals (Sweden)

    Allan HUYNH

    2010-07-01

    Full Text Available Existing systems to collect temperature and relative humidity data at cultural heritage buildings require technical knowledge by people who are working with it, which is very seldom that they do have. The systems available today also require manual downloading of the collected data from the sensor to a computer for central storage and for further analysis. In this paper a wireless remote sensor network based on the ZigBee technology together with a simplified data collection system is presented. The system does not require any knowledge by the building administrator after the network is deployed. The wireless sensor device will automatically join available network when the user wants to expand the network. The collected data will be automatically and periodically synchronized to a remote main server via an Internet connection. The data can be used for centralized monitoring and other purpose. The power consumption of the sensor module is also minimized and the battery lifetime is estimated up to 10 years.

  3. Radon as an Anthropogenic Indoor Air Pollutant

    Science.gov (United States)

    Gillmore, Gavin; Crockett, Robin

    2016-04-01

    Radon is generally regarded as a naturally occurring radiological hazard but we report here measurements of significant, hazardous radon concentrations that arise from man-made sources, including granite ornaments/artefacts, uranium glass and glazed objects as well radium dial watches. This presentation concerns an examination and assessment of health risks from radium and uranium found in historical artefacts, many of which were once viewed as everyday items, and the radon that emanates from them. Such objects were very popular in industrialised countries such as the USA, UK and European countries) particularly between and including the two World Wars but are still readily available. A watch collection examined gave rise to a hazardous radon concentration of 13.24 kBq•m-3 approximately 67 times the Domestic Action Level of 200 Bq•m-3.The results for an aircraft altimeter are comparable to those of the watches, indicating radon activity equivalent to several watches, and also indicate an equilibrium concentration in the 16.3 m3 room ca. 33 times the UK domestic Action Level. Results from a granite block indicate a radon emanation of 19.7 Bq•kg-1, but the indicated equilibrium concentration in the 16.3 m3 room is only ca. 1.7% of the UK domestic Action Level. Uranium-glazed crockery and green uranium glass were scoped for radon activity. The former yielded a radon concentration of ca. 44 Bq•m-3 in a small (7 L) sealed container. The latter yielded a lower radon concentration in a larger (125 L) sealed container of ca. 6 Bq•m-3. This is barely above the background radon concentration in the laboratory, which was typically ca. 1-2 Bq•m-3. Individual items then are capable of giving rise to radon concentrations in excess of the UK Domestic Action Level in rooms in houses, particularly if poorly ventilated. We highlight the gap in the remediation protocols, which are focused on preventing radon entering buildings from outside, with regard to internally

  4. A Monte Carlo study of radon detection in cylindrical diffusion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Rickards, Jorge, E-mail: rickards@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico); Golzarri, Jose-Ignacio, E-mail: golzarri@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico); Espinosa, Guillermo, E-mail: espinosa@fisica.unam.m [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito de la Investigacion Cientifica, Ciudad Universitaria, Delegacion Coyoacan, 04520 Mexico, D.F. (Mexico)

    2010-05-15

    The functioning of radon diffusion chambers was studied using the Monte Carlo code RAMMX developed here. The alpha particles from radon are assumed randomly produced in the volume of the cylinder, and those from the progeny are assumed to originate randomly at the cylindrical surface. The energy spectrum, the distribution of incident angles, and the distribution of path lengths of the alpha particles on the detector were obtained. These quantities vary depending on input parameters such as initial alpha particle energy, radius and depth of the diffusion chamber, detector size and atmospheric pressure. The calculated energy spectrum for both {sup 222}Rn and {sup 220}Rn was compared with experiment, permitting the identification of each peak and its origin, and a better understanding of radon monitoring. Three aspects not considered in previous calculations are progeny alphas coming from surfaces of the monitor, taking into account the atmospheric pressure, and including the isotope {sup 220}Rn.

  5. In Quest of the Bottleneck - Monitoring Parallel Database Systems

    NARCIS (Netherlands)

    S. Manegold (Stefan); F. Waas; D. Gudlat

    1997-01-01

    textabstractMonitoring query processing has proven to be an effective technique to detect bottlenecks in sequential query execution systems' components. Monitoring distributed execution in parallel systems, however, is a difficult task. The monitoring data of all nodes must be collected at the same

  6. Network-Oriented Radiation Monitoring System (NORMS)

    Energy Technology Data Exchange (ETDEWEB)

    Rahmat Aryaeinejad; David F. Spencer

    2007-10-01

    We have developed a multi-functional pocket radiation monitoring system capable of detecting and storing gamma ray and neutron data and then sending the data through a wireless connection to a remote central facility upon request. The device has programmable alarm trigger levels that can be modified for specific applications. The device could be used as a stand-alone device or in conjunction with an array to cover a small or large area. The data is stored with a date/time stamp. The device may be remotely configured. Data can be transferred and viewed on a PDA via direct connection or wirelessly. Functional/bench tests have been completed successfully. The device detects low-level neutron and gamma sources within a shielded container in a radiation field of 10 uR/hr above the ambient background level.

  7. The Creation of Differential Correction Systems and the Systems of Global Navigation Satellite System Monitoring

    National Research Council Canada - National Science Library

    Polishchuk, G. M; Kozlov, V. I; Urlichich, Y. M; Dvorkin, V. V; Gvozdev, V. V

    2002-01-01

    ... for the Russian Federation and a system of global navigation satellite system monitoring. These projects are some of the basic ones in the Federal program "Global Navigation System," aimed at maintenance and development of the GLONASS system...

  8. System monitoring and diagnosis with qualitative models

    Science.gov (United States)

    Kuipers, Benjamin

    1991-01-01

    A substantial foundation of tools for model-based reasoning with incomplete knowledge was developed: QSIM (a qualitative simulation program) and its extensions for qualitative simulation; Q2, Q3 and their successors for quantitative reasoning on a qualitative framework; and the CC (component-connection) and QPC (Qualitative Process Theory) model compilers for building QSIM QDE (qualitative differential equation) models starting from different ontological assumptions. Other model-compilers for QDE's, e.g., using bond graphs or compartmental models, have been developed elsewhere. These model-building tools will support automatic construction of qualitative models from physical specifications, and further research into selection of appropriate modeling viewpoints. For monitoring and diagnosis, plausible hypotheses are unified against observations to strengthen or refute the predicted behaviors. In MIMIC (Model Integration via Mesh Interpolation Coefficients), multiple hypothesized models of the system are tracked in parallel in order to reduce the 'missing model' problem. Each model begins as a qualitative model, and is unified with a priori quantitative knowledge and with the stream of incoming observational data. When the model/data unification yields a contradiction, the model is refuted. When there is no contradiction, the predictions of the model are progressively strengthened, for use in procedure planning and differential diagnosis. Only under a qualitative level of description can a finite set of models guarantee the complete coverage necessary for this performance. The results of this research are presented in several publications. Abstracts of these published papers are presented along with abtracts of papers representing work that was synergistic with the NASA grant but funded otherwise. These 28 papers include but are not limited to: 'Combined qualitative and numerical simulation with Q3'; 'Comparative analysis and qualitative integral representations

  9. Test, Control and Monitor System maintenance plan

    Science.gov (United States)

    Buehler, David P.; Lougheed, M. J.

    1993-01-01

    The maintenance requirements for Test, Control, and Monitor System (TCMS) and the method for satisfying these requirements prior to First Need Date (FND) of the last TCMS set are described. The method for satisfying maintenance requirements following FND of the last TCMS set will be addressed by a revision to this plan. This maintenance plan serves as the basic planning document for maintenance of this equipment by the NASA Payloads Directorate (CM) and the Payload Ground Operations Contractor (PGOC) at KSC. The terms TCMS Operations and Maintenance (O&M), Payloads Logistics, TCMS Sustaining Engineering, Payload Communications, and Integrated Network Services refer to the appropriate NASA and PGOC organization. For the duration of their contract, the Core Electronic Contractor (CEC) will provide a Set Support Team (SST). One of the primary purposes of this team is to help NASA and PGOC operate and maintain TCMS. It is assumed that SST is an integral part of TCMS O&M. The purpose of this plan is to describe the maintenance concept for TCMS hardware and system software in order to facilitate activation, transition planning, and continuing operation. When software maintenance is mentioned in this plan, it refers to maintenance of TCMS system software.

  10. Beam position monitoring system at CESR

    Science.gov (United States)

    Billing, M. G.; Bergan, W. F.; Forster, M. J.; Meller, R. E.; Rendina, M. C.; Rider, N. T.; Sagan, D. C.; Shanks, J.; Sikora, J. P.; Stedinger, M. G.; Strohman, C. R.; Palmer, M. A.; Holtzapple, R. L.

    2017-09-01

    The Cornell Electron-positron Storage Ring (CESR) has been converted from a High Energy Physics electron-positron collider to operate as a dedicated synchrotron light source for the Cornell High Energy Synchrotron Source (CHESS) and to conduct accelerator physics research as a test accelerator, capable of studying topics relevant to future damping rings, colliders and light sources. Some of the specific topics that were targeted for the initial phase of operation of the storage ring in this mode, labeled CESRTA (CESR as a Test Accelerator), included 1) tuning techniques to produce low emittance beams, 2) the study of electron cloud development in a storage ring and 3) intra-beam scattering effects. The complete conversion of CESR to CESRTA occurred over a several year period and is described elsewhere. As a part of this conversion the CESR beam position monitoring (CBPM) system was completely upgraded to provide the needed instrumental capabilities for these studies. This paper describes the new CBPM system hardware, its function and representative measurements performed by the upgraded system.

  11. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Rabusov, Andrey

    2014-01-01

    During the LHCb running in 2011 and 2012 it was found that the precision of PMT gain monitoring with LED system is affected by radiation damage of the long light guides transporting LED light to calorimeter cells. It was decided to replace in 2014 the present light guides to new ones that should be made of radiation tolerant quartz fibers. After the replacement, the system requires full tuning. It includes adjustment of the LED flash agnitudes and delays, and, after that, adjustment of the PIN diode system. My work was the following: to adjust the PIN signal amplitudes. This included a rough equalization of the amplitudes of signal from the 4 or 2 LEDs served by each PIN diode (achieved by mechanical adjustment of positions of corresponding fibers with respect to the PIN), and then reducing the PIN signal amplitude to the middle of the ADC range when necessary (total of 40 resistive attenuators were produced for this); to find timing corrections for ADCs digitizing the PIN signals; perform a PMT gain measure...

  12. Assessment and management of residential radon health risks: a report from the health Canada radon workshop.

    Science.gov (United States)

    Tracy, Bliss L; Krewski, Daniel; Chen, Jing; Zielinski, Jan M; Brand, Kevin P; Meyerhof, Dorothy

    2006-04-01

    Epidemiologic studies of uranium miners and other underground miners have consistently shown miners exposed to high levels of radon to be at increased risk of lung cancer. More recently, concern has arisen about lung cancer risks among people exposed to lower levels of radon in homes. The current Canadian guideline for residential radon exposure was set in 1988 at 800 Bq/m(3). Because of the accumulation of a considerable body of new scientific evidence on radon lung cancer risks since that time, Health Canada sponsored a workshop to review the current state-of-the-science on radon health risks. The specific objectives of the workshop were (1) to collect and assess scientific information relevant to setting national radon policy in Canada, and (2) to gather information on social, political, and operational considerations in setting national policy. The workshop, held on 3-4 March 2004, was attended by 38 invited scientists, regulators, and other stakeholders from Canada and the United States. The presentations on the first day dealt primarily with scientific issues. The combined analysis of North American residential radon and lung cancer studies was reviewed. The analysis confirmed a small but detectable increase in lung cancer risk at residential exposure levels. Current estimates suggest that radon in homes is responsible for approximately 10% of all lung cancer deaths in Canada, making radon the second leading cause of lung cancer after tobacco smoking. This was followed by a perspective from an UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) working group on radon. There were two presentations on occupational exposures to radon and two presentations considered the possibility of radon as a causative factor for cardiovascular disease and for cancer in other organs besides the lung. The possible contribution of environmental tobacco smoke to lung cancers in nonsmokers was also considered. Areas for future research were identified

  13. Air Quality System (AQS) Monitoring Network, EPA OAR OAQPS

    Data.gov (United States)

    U.S. Environmental Protection Agency — This GIS dataset contains points which depict air quality monitors within EPA's Air Quality System (AQS) monitoring network. This dataset is updated weekly to...

  14. RadNet (Environmental Radiation Ambient Monitoring System)

    Data.gov (United States)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  15. Real-time remote monitoring system for aquaculture water quality

    National Research Council Canada - National Science Library

    Luo Hongpin; Li Guanglin; Peng Weifeng; Song Jie; Bai Qiuwei

    2015-01-01

      A multi-parameters monitoring system based on wireless network was set up to achieve remote real-time monitoring of aquaculture water quality, in order to improve the quality of aquaculture products...

  16. Development of a novel fiber-optic sensor to measure radon in the deep ocean

    Science.gov (United States)

    Monteiro, Catarina; Guimarães, Diana; Jorge, Pedro; Barbosa, Susana

    2017-04-01

    The radon concentration in the deep ocean has gained increasing interest in the last decades. The underwater monitoring of this natural radioactive gas can give important information about submarine groundwater discharges, groundwater migration and contamination. Radon concentration has also been studied as a possible indicator of earthquake events which can have devastating consequences when the epicenter is located at the sea. In contrast with radon monitoring studies in caves, mines, and underground soil, there is an utter lack of information about radon in deep-sea. These measurements are particularly difficult to attain due to the challenges that marine-like environments post to electronic sensing devices and their maintenance over time. Gamma rays emitted by radon's progeny can be easily detected when interacting with a scintillator material. Recently, optical fiber doped with scintillating material has emerged has an alternative for gamma ray detection. The lightweight, low transmission loss, immunity to electromagnetic interference and the cost effectiveness makes optical fiber a compelling solution for radiation detection when compared to conventional sensors. In this work a compact all-fiber optical sensor is developed for continuous gamma ray detection in the deep sea. This sensor is composed by a scintillating optical fiber coupled to a polymeric optical fiber that allows the detection of low levels of radiation.

  17. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  18. The distribution of indoor radon in Transylvania (Romania) - influence of the natural and anthropogenic factors

    Science.gov (United States)

    Cucos Dinu, Alexandra; Baciu, Calin; Dicu, Tiberius; Papp, Botond; Moldovan, Mircea; Bety Burghele, Denissa; Tenter, Ancuta; Szacsvai, Kinga

    2017-04-01

    Exposure to radon in homes and workplaces is now recognized as the most important natural factor in causing lung cancer. Radon activity is usually higher in buildings than in the outside atmosphere, as it may be released from building materials and soil beneath the constructions, and the concentration builds-up indoor, due to the low air renewal rates. Indoor radon levels can vary from one to multiple orders of magnitude over time and space, as it depends on several natural and anthropogenic factors, such us the radon concentration in soil under the construction, the weather conditions, the degree of containment in the areas where individuals are exposed, building materials, outside air, tap water and even city gas, the architecture, equipment (chimney, mechanical ventilation systems, etc.), the environmental parameters of the building (temperature, pressure, etc.), and on the occupants' lifestyle. The study presents the distribution of indoor radon in Transylvania, Romania, together with the measurements of radon in soil and soil water. Indoor radon measurements were performed by using CR-39 track detectors exposed for 3 months on ground-floor level of dwellings, according to the NRPB Measurement Protocol. Radon concentrations in soil and water were measured using the LUK3C device. A complete map was plotted at the date, based on 3300 indoor radon measurements, covering an area of about 42% of the Romanian territory. The indoor radon concentrations ranged from 5 to 3287 Bq m-3, with an updated preliminary arithmetic mean of 179 Bq m-3, and a geometric mean of 122 Bq m-3. In about 11% of the investigated grid cells the indoor radon concentrations exceed the threshold of 300 Bq m-3. The soil gas radon concentration varies from 0.8 to 169 kBq m-3, with a geometric mean of 26 kBq m-3. For water samples, the results show radon concentrations within the range of 0.3 - 352.2 kBq m-3, with a geometric mean of 7.7 Bq L-1. A weak correlation between the three sets of values

  19. Systematic radon survey over active volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, J.L.; Monnin, M.; Garcia Vindas, J.R. [Centre National de la Recherche Cientifique, Montpellier (France). Lab. GBE; Ricard, L.P.; Staudacher, T. [Observatoire Volcanologique Du Pitou de la Fournaise, La Plaine des Cafres (France)

    1999-08-01

    Data obtained since 1993 on Costa Rica volcanos are presented and radon anomalies recorded before the eruption of the Irazu volcano (December 8, 1994) are discussed. The Piton de la Fournaise volcano is inactive since mid 1992. The influence of the external parameters on the radon behaviour is studied and the type of perturbations induced on short-term measurements are individuate.

  20. Removal of Radon from Household Water.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Research and Development.

    By far, the greatest risk to health from radon occurs when the gas enters the house from underlying soil and is inhaled. The U.S. Environmental Protection Agency (EPA) is studying ways to reduce radon in houses, including methods to remove the gas from water to prevent its release in houses when the water is used. While this research has not…

  1. Radon Measurements in Schools: An Interim Report.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Radiation Programs.

    Radon-222 is a colorless, odorless, tasteless, radioactive gas that occurs naturally in soil, rocks, underground water, and air. The United States Environmental Protection Agency (EPA) and other scientific organizations have identified an increased risk of lung cancer associated with exposure to elevated levels of radon in homes. Schools in many…

  2. Radon Measurement in Schools. Revised Edition.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    The Environmental Protection Agency (EPA) and other major national and international scientific organizations have concluded that radon is a human carcinogen and a serious environmental health problem. The EPA has conducted extensive research on the presence and measurement of radon in schools. This report provides school administrators and…

  3. Radon Reduction Methods: A Homeowner's Guide.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC.

    The U.S. Environmental Protection Agency (EPA) is studying the effectiveness of various ways to reduce high concentrations of radon in houses. This booklet was produced to share what has been learned with those whose radon problems demand immediate action. The booklet describes nine methods that have been tested successfully--by EPA and/or other…

  4. Decadal radon cycles in a hot spring.

    Science.gov (United States)

    Yan, Rui; Woith, Heiko; Wang, Rongjiang; Wang, Guangcai

    2017-09-21

    A high-fidelity record covering nearly 40 years of water-dissolved radon from the hot spring site of BangLazhang (BLZ), Southwestern China is presented to study multi-year periodicities of radon. Ancillary observational data, i.e., water temperature, spring discharge rate, barometric pressure, combined with regional rainfall, galactic cosmic rays (GCR flux is modulated by solar wind and thus a proxy for solar activity) and regional seismicity from the same period are considered to identify potentially influencing factors controlling the changes in radon. Variations in radon concentration and ancillary observational data are studied using continuous Wavelet Power Spectrum (WPS), Wavelet Coherence (WTC), and Partial Wavelet Coherence (PWC). The results show that the long-period radon concentration is characterized by a quasi-decadal (8-11 years) cycle, matching well with the concurrent periodicity in water temperature, spring discharge rates and GCR. PWCs of radon, discharge rate and water temperature suggest that water temperature variations explain most of the coherent variability of radon and the discharge rate. We tentatively conclude that radon variations are mainly explained by variations in water temperature and spring discharge, which are modified and modulated by earthquakes and quasi-decadal variations of an unidentified process. The influence of solar activity on the decadal periodicity is discussed.

  5. Estimation of Indoor Radon from Concrete Blocks Used In ...

    African Journals Online (AJOL)

    Radon gas is the most important source of natural radiation. Indoor radon concentration is the main path of human exposure to high radon concentration. Radon contribution from concrete block walls of typical Nigerian dwellings has been estimated from gamma ray spectroscopy measurements of radium concentration ...

  6. Find a Radon Test Kit or Measurement and Mitigation Professional

    Science.gov (United States)

    Find a qualified radon service professional to fix or mitigate your home. If you have questions about a radon, you should contact your state radon contact and/or contact one or both of the two privately-run National Radon Proficiency Programs

  7. Current status of technology development on remote monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  8. Survey of remote data monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Logee, T.L.; Kendall, P.W.; Pollock, E.O.; Raymond, M.G.; Knapp, R.C. Jr.

    1984-09-01

    A self-contained data-logger device called an SDAS (Site Data Acquisition Subsystem) was built for the National Solar Data Network (NSDN) which could collect analog data from 96 channels, store the data for up to three days, and then transmit the stored data on request to a central facility by voice-grade telephone lines. This system has worked fairly well for the eight years that it has been in service. However, the design and components are getting old and newer dataloggers may be more reliable and accurate and less expensive. This report discusses the results of an extensive search for an SDAS replacement. The survey covered 62 models from 36 manufacturers. These numbers are not indicative of all the dataloggers or manufacturers available, but only those which appeared to have some qualifications for the NSDN datalogger replacement. This report views the datalogger as a system which is made up of sensors, a data acquisition and storage unit, a telecommunications subsystem, and a data processing subsystem. Therefore, there is a section on sensors used in the NSDN, telecommunications technology, and data processing requirements. These four components or subsystems are all necessary in order to have an integrated, successful remote data monitoring network.

  9. Design of CMS Beam Halo Monitor system

    CERN Document Server

    AUTHOR|(CDS)2078842

    2015-01-01

    A fast and directional monitoring system for the CMS experiment is designed to provide an online, bunch-by-bunch measurement of beam background induced by beam halo interactions, separately for each beam. The background detection is based on Cherenkov radiation produced in synthetic fused silica read out by a fast, UV sensitive photomultiplier tube. Twenty detector units per end will be azimuthally distributed around the rotating shielding of CMS, covering ~408 cm2 at 20.6m from the interaction point, at a radius of ~180 cm. The directional and fast response of the system allows the discrimination of the background particles from the dominant flux in the cavern induced by pp collision debris, produced within the 25 ns bunch spacing. A robust multi-layered shielding will enclose each detector unit to protect the photomultiplier tube from the magnetic field and to eliminate the occupancy from low energy particles. The design of the front-end units is validated by experimental results. An overview of the new sy...

  10. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  11. Indoor radon concentration data: Its geographic and geologic distribution, an example from the Capital District, NY

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J.J. [Skidmore College, Saratoga Springs, NY (United States); Overeynder, H.M. [C.E.S., Gabon (Central African Republic); Thomas, B.R. [CMT Independent Laboratories, Clifton Park, NY (United States)

    1995-09-01

    Most studies of the geographic distribution of indoor radon levels are plotted by county or ZIP code. This method is used for the radon potential maps produced by the U.S. Environmental Protection Agency (EPA) and the New York State Department of Health (NYSDOH). The basis for the mapping is the mean or median indoor radon count for all the data provided by NYSDOH within each geographic area. While testing the indoor radon analyses provided to the authors by CMT Independent Laboratories, we discovered data that deviated markedly from the EPA and NYSDOH means for the Capital District of New York (Albany and surrounding counties). Their screening indoor radon average concentrations in pCi/L, indicate low potential for Schenectady (3.0), Saratoga (3.2), and Albany (3.7) counties; and moderate potential for Rensselaer (6.4) and Columbia (7.0) counties. Our database of over 3,000 analyses contains over 800 records of indoor radon counts above 4 pCi/L (14-47% of each county`s analyses), many high enough to be rated as a serious health hazard. In order to obtain greater precision of information, the authors plotted their indoor radon data by street address using MapInfo, a geographic Information System (GIS), and StreetInfo, MapInfo`s TIGER address database. We compared the geographic distribution of our data to both the Bedrock Geology and Surficial Geology Maps of New York State. The results show a striking relationship of radon concentrations to bedrock, faults and permeability of surficial material. Data being compiled and mapped by street address by the NYSDOH in Erie County in western New York, confirm our results.

  12. Novel method of measurement of radon exhalation from building materials.

    Science.gov (United States)

    Awhida, A; Ujić, P; Vukanac, I; Đurašević, M; Kandić, A; Čeliković, I; Lončar, B; Kolarž, P

    2016-11-01

    In the era of the energy saving policy (i.e. more air tight doors and windows), the radon exhaled from building materials tends to increase its concentration in indoor air, which increases the importance of the measurement of radon exhalation from building materials. This manuscript presents a novel method of the radon exhalation measurement using only a HPGe detector or any other gamma spectrometer. Comparing it with the already used methods of radon exhalation measurements, this method provides the measurement of the emanation coefficient, the radon diffusion length and the radon exhalation rate, all within the same measurement, which additionally defines material's radon protective properties. Furthermore it does not necessitate additional equipment for radon or radon exhalation measurement, which simplifies measurement technique, and thus potentially facilitates introduction of legal obligation for radon exhalation determination in building materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Continuous remote unattended monitoring for safeguards data collection systems

    Energy Technology Data Exchange (ETDEWEB)

    Klosterbuer, S.F.; Halbig, J.K.; Harker, W.C.; Menlove, H.O.; Painter, J.A.; Stewart, J.E.

    1994-02-01

    To meet increased inspection requirements, unattended and remote monitoring systems have been developed and installed in several large facilities to perform safeguards functions. These unattended monitoring systems are based on instruments originally developed for traditional safeguards and the domestic nuclear industry to nondestructively assay nuclear materials. Through specialized measurement procedures, these instruments have been adapted to be unattended monitors. This paper defines the parts of these unattended monitoring systems, describes the systems that have been installed in the field and their status, and discusses future trends for unattended systems.

  14. Domestic Radon Exposure and Risk of Childhood Cancer: A Prospective Census-Based Cohort Study

    Science.gov (United States)

    Hauri, Dimitri; Spycher, Ben; Huss, Anke; Zimmermann, Frank; Grotzer, Michael; von der Weid, Nicolas; Weber, Damien; Spoerri, Adrian; Kuehni, Claudia E.

    2013-01-01

    Background: In contrast with established evidence linking high doses of ionizing radiation with childhood cancer, research on low-dose ionizing radiation and childhood cancer has produced inconsistent results. Objective: We investigated the association between domestic radon exposure and childhood cancers, particularly leukemia and central nervous system (CNS) tumors. Methods: We conducted a nationwide census-based cohort study including all children radon levels were estimated for each individual home address using a model developed and validated based on approximately 45,000 measurements taken throughout Switzerland. Data were analyzed with Cox proportional hazard models adjusted for child age, child sex, birth order, parents’ socioeconomic status, environmental gamma radiation, and period effects. Results: In total, 997 childhood cancer cases were included in the study. Compared with children exposed to a radon concentration below the median (radon exposure is associated with childhood cancer, despite relatively high radon levels in Switzerland. Citation: Hauri D, Spycher B, Huss A, Zimmermann F, Grotzer M, von der Weid N, Weber D, Spoerri A, Kuehni C, Röösli M, for the Swiss National Cohort and the Swiss Paediatric Oncology Group (SPOG). 2013. Domestic radon exposure and risk of childhood cancer: a prospective census-based cohort study. Environ Health Perspect 121:1239–1244; http://dx.doi.org/10.1289/ehp.1306500 PMID:23942326

  15. Use of simulink to address key factors for radon mitigation in a Fairbanks home.

    Science.gov (United States)

    Marsik, Tom; Johnson, Ron

    2008-05-01

    Hilly areas around Fairbanks, Alaska, are known to have elevated soil radon concentrations. Due to geological conditions, cold winters, and the resulting stack effect, houses in these areas are prone to higher indoor radon concentrations. Key variables with respect to radon mitigation were addressed in this paper by using a dynamic model implemented in MATLAB Simulink. These variables included the ventilation rate; the foundation flow resistance, which can be affected by sealing the foundation during the construction of a house; and the differential pressure between the subslab and the house interior, which can be affected by using a subslab depressurization system. The model was used for the scenario of a varying differential pressure and then for the scenario of a varying ventilation rate at a Fairbanks home where real-time radon concentrations were measured. The correlation coefficients between the model-predicted and measured radon concentrations were 0.96 and 0.94, for both scenarios respectively, which verified the feasibility of the model for predicting indoor radon concentrations.

  16. Prediction of lung cells oncogenic transformation for induced radon progeny alpha particles using sugarscape cellular automata.

    Science.gov (United States)

    Baradaran, Samaneh; Maleknasr, Niaz; Setayeshi, Saeed; Akbari, Mohammad Esmaeil

    2014-01-01

    Alpha particle irradiation from radon progeny is one of the major natural sources of effective dose in the public population. Oncogenic transformation is a biological effectiveness of radon progeny alpha particle hits. The biological effects which has caused by exposure to radon, were the main result of a complex series of physical, chemical, biological and physiological interactions. The cellular and molecular mechanisms for radon-induced carcinogenesis have not been clear yet. Various biological models, including cultured cells and animals, have been found useful for studying the carcinogenesis effects of radon progeny alpha particles. In this paper, sugars cape cellular automata have been presented for computational study of complex biological effect of radon progeny alpha particles in lung bronchial airways. The model has included mechanism of DNA damage, which has been induced alpha particles hits, and then formation of transformation in the lung cells. Biomarkers were an objective measure or evaluation of normal or abnormal biological processes. In the model, the metabolism rate of infected cell has been induced alpha particles traversals, as a biomarker, has been followed to reach oncogenic transformation. The model results have successfully validated in comparison with "in vitro oncogenic transformation data" for C3H 10T1/2 cells. This model has provided an opportunity to study the cellular and molecular changes, at the various stages in radiation carcinogenesis, involving human cells. It has become well known that simulation could be used to investigate complex biomedical systems, in situations where traditional methodologies were difficult or too costly to employ.

  17. Radon and radium concentration in water from North-West of Romania and the estimated doses.

    Science.gov (United States)

    Moldovan, M; Benea, V; Niţă, D C; Papp, B; Burghele, B D; Bican-Brişan, N; Cosma, C

    2014-11-01

    In the present study, the measurements of radon were carried out using the LUK-VR system based on radon gas measurements with Lucas cells. The radium concentration in water was determined, with the same device, immediately after was established the radon equilibrium with radium. The results presented here are from a survey carried out in the N-W region of Transylvania (Romania) in which were investigated the radon concentrations in natural (spring, well and surface) and drinking (tap) waters. The results showed radon concentrations within the range of 0.4-187.3 Bq l(-1) with an average value of 15.9 Bq l(-1) whereas radium concentration varied between 0.05 and 0.825 Bq l(-1) with an average value of 0.087 Bq l(-1) for all types of water covered within this survey. The corresponding annual effective ingestion dose due to radon and radium from water was determined from drinking water used by the population inhabiting the area. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Passive and active measurements of radon-related parameters inside ancient Egyptian tombs in Luxor

    Energy Technology Data Exchange (ETDEWEB)

    Abo-Elmagd, M. [Radiation Measurements Department, National Institute for Standard, Giza (Egypt)]. E-mail: abo_elmgd@hotmail.com; Metwally, S.M. [Faculty of Science, Department of Physics, Ain Shams University, Cairo (Egypt); El-Fiki, S.A. [Faculty of Science, Department of Physics, Ain Shams University, Cairo (Egypt); Eissa, H.M. [Radiation Measurements Department, National Institute for Standard, Giza (Egypt); Salama, E. [Faculty of Science, Department of Physics, Ain Shams University, Cairo (Egypt)

    2007-01-15

    Radon and its related parameters were measured using passive (CR-39) and active (Alpha-Guard analyzer) techniques inside seven ancient Egyptian tombs of the Valley of the Kings in Luxor. The measurements were performed throughout the winter and summer seasons. The average radon concentration inside the tombs ranges from 96.9+/-10.8 to 415+/-43Bqm{sup -3} in winter and from 86.4+/-13.8 to 6102.8+/-573.6 in summer. Because of the variations of tombs dimensions and their ventilation systems, the equilibrium factor between radon and its progeny ranges from 0.228+/-0.02 to 0.95+/-0.05. The effective doses for the tomb workers, the tour guide and visitors were calculated. Active measurements show that radon exhalation rates range from 0.68+/-0.30 to 1.47+/-0.27Bqm{sup -2}h{sup -1} and from 0.60+/-0.03 to 1.42+/-0.05Bqm{sup -2}h{sup -1} for passive measurements. The real radium content was determined for all examined tombs by HPGe detector, while the effective radium content was obtained by Alpha-Guard and sealed cup techniques. Radon exhalation rates were correlated with the real radium content. A good correlation was found between active and passive measurements of radon exhalation rate.

  19. Diffusion of radon through concrete block walls: A significant source of indoor radon

    Science.gov (United States)

    Lively, R.S.; Goldberg, L.F.

    1999-01-01

    Basement modules located in southern Minnesota have been the site of continuous radon and environmental measurements during heating seasons since 1993. Concentrations of radon within the basement modules ranged from 70 Bq.m-3 to over 4000 Bq.m-3 between November to April during the three measurement periods. In the soil gas for the same times, concentrations of radon ranged between 25,000 and 70,000 Bq.m-3. Levels of radon within the basement modules changed by factors of five or more within 24 h, in concert with pressure gradients of 4 to 20 Pa that developed between the basement modules and their surroundings. Diffusion is identified as the principal method by which radon is transferred into and out of the basement modules, and appears to be relatively independent of insulating materials and vapour retarders. The variability of radon and correlations with differential pressure gradients may be related to air currents in the block walls and soil that interrupt radon diffusing inward. This yields a net decrease of radon in the basement modules by decay and outward diffusion. Levels of radon within the basement modules increase when the pressure differential is zero and air flow ceases, allowing diffusion gradients to be re-established. Radon levels in both the soil and the basement modules then increase until an equilibrium is achieved.

  20. Structural health monitoring system using internet and database technologies

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chi Yeop; Choi, Man Yong; Kwon, Il Bum; Lee, Seung Seok [Nonstructive Measurment Lab., KRISS, Daejeon (Korea, Republic of)

    2003-07-01

    Structure health monitoring system should develope to be based on internet and database technology in order to manage efficiency large structures. This system is operated by internet connected with the side of structures. The monitoring system has some functions: self monitoring, self diagnosis, and self control etc. Self monitoring is the function of sensor fault detection. If some sensors are not normally worked, then this system can detect the fault sensors. Also Self diagnosis function repair the abnormal condition of sensors. And self control is the repair function of the monitoring system. Especially, the monitoring system can identify the replacement of sensors. For further study, the real application test will be performed to check some unconviniences.