WorldWideScience

Sample records for radiotracer rotation angles

  1. Regional wall thickening in gated myocardial perfusion SPECT in a Japanese population: effect of sex, radiotracer, rotation angles and frame rates

    Energy Technology Data Exchange (ETDEWEB)

    Akhter, Nasima; Nakajima, Kenichi; Okuda, Koichi; Matsuo, Shinro; Yoneyama, Tatsuya; Taki, Junichi; Kinuya, Seigo [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa, Ishikawa (Japan)

    2008-09-15

    Gated single-photon emission computed tomography (SPECT) imaging of myocardium by {sup 99m}Tc and {sup 201}Tl is used extensively to measure quantitative cardiac functional parameters. However, factors affecting normal values for myocardial functional parameters and population-specific standards have not yet been established. The aim of the study was to determine the effect of sex, radiotracer, rotation angles and frame rates on resting myocardial wall thickening (WT) and to develop a Japanese standard of normal values for WT. Data from a total of 202 patients with low possibility of having cardiac problems were collected from nine hospitals throughout Japan. Patients were divided into five groups according to study protocol, and WT was evaluated according to the 17-segment and four-region (basal, mid and apical regions and the apex) polar map distribution. WT was generally higher in women than in men irrespective of the use of radiotracers, rotation angles or frame rates, and the difference was highly significant in the mid and apical regions. In any protocol used, resting myocardial thickening in the apex was higher than in the mid and apical regions, and thickening was lowest in the basal region, suggesting heterogeneous regional myocardial thickening (%) in normal subjects. Different rotation angles showed no significant change on WT, but different frame rates and tracers showed significant WT change in both sexes. Percent thickening of the myocardium was significantly higher in imaging by {sup 99m}Tc-labelled tracers than in {sup 201}Tl. Sex, radiotracers and frame rates had a significant effect on myocardial thickening, and the importance of population-specific standards should be emphasized. A normal database can serve as a standard for gated SPECT evaluation of myocardial thickening in a Japanese population and might be applicable to Asian populations having a similar physique. (orig.)

  2. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    OpenAIRE

    Luo Jun; Wang Zhiqian; Shen Chengwu; Wen Zhuoman; Liu Shaojin; Cai Sheng; Li Jianrong

    2015-01-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendic...

  3. Non-contact measurement of rotation angle with solo camera

    Science.gov (United States)

    Gan, Xiaochuan; Sun, Anbin; Ye, Xin; Ma, Liqun

    2015-02-01

    For the purpose to measure a rotation angle around the axis of an object, a non-contact rotation angle measurement method based on solo camera was promoted. The intrinsic parameters of camera were calibrated using chessboard on principle of plane calibration theory. The translation matrix and rotation matrix between the object coordinate and the camera coordinate were calculated according to the relationship between the corners' position on object and their coordinates on image. Then the rotation angle between the measured object and the camera could be resolved from the rotation matrix. A precise angle dividing table (PADT) was chosen as the reference to verify the angle measurement error of this method. Test results indicated that the rotation angle measurement error of this method did not exceed +/- 0.01 degree.

  4. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Wen, Zhuoman; Liu, Shaojin; Cai, Sheng; Li, Jianrong

    2015-10-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  5. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Directory of Open Access Journals (Sweden)

    Luo Jun

    2015-10-01

    Full Text Available This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  6. Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Sen; Li, Guangjun; Wang, Maojie; Jiang, Qinfeng; Zhang, Yingjie [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China); Wei, Yuquan, E-mail: yuquawei@vip.sina.com [State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, Chengdu, Sichuan (China)

    2013-07-01

    The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

  7. A novel method of measuring spatial rotation angle using MEMS tilt sensors

    International Nuclear Information System (INIS)

    Cao, Jian’an; Zhu, Xin; Zhang, Leping; Wu, Hao

    2017-01-01

    This paper presents a novel method of measuring spatial rotation angle with a dual-axis micro-electro-mechanical systems tilt sensor. When the sensor is randomly mounted on the surface of the rotating object, there are three unpredictable and unknown mounting position parameters: α , the sensor’s swing angle on the measuring plane; β , the angle between the rotation axis and the horizontal plane; and γ , the angle between the measuring plane and the rotation axis. Thus, the sensor’s spatial rotation model is established to describe the relationship between the measuring axis, rotation axis, and horizontal plane, and the corresponding analytical equations are derived. Furthermore, to eliminate the deviation caused by the uncertain direction of the rotation axis, an extra perpendicularly mounted, single-axis tilt sensor is combined with the dual-axis tilt sensor, forming a three-axis tilt sensor. Then, by measuring the sensors’ three tilts and solving the model’s equations, the object’s spatial rotation angle is obtained. Finally, experimental results show that the developed tilt sensor is capable of measuring spatial rotation angle in the range of  ±180° with an accuracy of 0.2° if the angle between the rotation axis and the horizontal plane is less than 75°. (paper)

  8. Transperineal ultrasonography in stress urinary incontinence: The significance of urethral rotation angles.

    Science.gov (United States)

    Al-Saadi, Wasan Ismail

    2016-03-01

    To assess, using transperineal ultrasonography (TPUS), the numerical value of the rotation of the bladder neck [represented by the difference in the anterior (α angle) and posterior urethral anglesangle)] at rest and straining, in continent women and women with stress urinary incontinence (SUI), to ascertain if there are significant differences in the angles of rotation (Rα and Rβ) between the groups. In all, 30 women with SUI (SUI group) and 30 continent women (control group) were included. TPUS was performed at rest and straining (Valsalva manoeuver), and the threshold value for the urethral angles (α and β angles) for each group were estimated. The degree of rotation for each angle was calculated and was considered as the angle of rotation. Both the α and β angles were significantly different between the groups at rest and straining, and there was a significant difference in the mean increment in the value of each angle. Higher values of increment (higher rotation angles) were reported in the SUI group for both the α and β angles compared with those of the control group [mean (SD) Rα SUI group 19.43 (12.76) vs controls 10.53 (2.98) °; Rβ SUI group 28.30 (12.96) vs controls 16.33 (10.8) °; P < 0.001]. Urethral rotation angles may assist in the assessment and diagnosis of patients with SUI, which may in turn reduce the need for more sophisticated urodynamic studies.

  9. Emission-angle and polarization-rotation effects in the lensed CMB

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Antony [Department of Physics and Astronomy, University of Sussex, Brighton BN1 9QH (United Kingdom); Hall, Alex [Institute for Astronomy, University of Edinburgh, Royal Observatory, Blackford Hill, Edinburgh, EH9 3HJ (United Kingdom); Challinor, Anthony, E-mail: antony@cosmologist.info, E-mail: ahall@roe.ac.uk, E-mail: a.d.challinor@ast.cam.ac.uk [Institute of Astronomy and Kavli Institute for Cosmology, Madingley Road, Cambridge, CB3 0HA (United Kingdom)

    2017-08-01

    Lensing of the CMB is an important effect, and is usually modelled by remapping the unlensed CMB fields by a lensing deflection. However the lensing deflections also change the photon path so that the emission angle is no longer orthogonal to the background last-scattering surface. We give the first calculation of the emission-angle corrections to the standard lensing approximation from dipole (Doppler) sources for temperature and quadrupole sources for temperature and polarization. We show that while the corrections are negligible for the temperature and E-mode polarization, additional large-scale B-modes are produced with a white spectrum that dominates those from post-Born field rotation (curl lensing). On large scales about one percent of the total lensing-induced B-mode amplitude is expected to be due to this effect. However, the photon emission angle does remain orthogonal to the perturbed last-scattering surface due to time delay, and half of the large-scale emission-angle B modes cancel with B modes from time delay to give a total contribution of about half a percent. While not important for planned observations, the signal could ultimately limit the ability of delensing to reveal low amplitudes of primordial gravitational waves. We also derive the rotation of polarization due to multiple deflections between emission and observation. The rotation angle is of quadratic order in the deflection angle, and hence negligibly small: polarization typically rotates by less than an arcsecond, orders of magnitude less than a small-scale image rotates due to post-Born field rotation (which is quadratic in the shear). The field-rotation B modes dominate the other effects on small scales.

  10. Path integral of the angular momentum eigenstates evolving with the parameter linked with rotation angle under the space rotation transformation

    International Nuclear Information System (INIS)

    Zhang Zhongcan; Hu Chenguo; Fang Zhenyun

    1998-01-01

    The authors study the method which directly adopts the azimuthal angles and the rotation angle of the axis to describe the evolving process of the angular momentum eigenstates under the space rotation transformation. The authors obtain the angular momentum rotation and multi-rotation matrix elements' path integral which evolves with the parameter λ(0→θ,θ the rotation angle), and establish the general method of treating the functional (path) integral as a normal multi-integrals

  11. The new INRIM rotating encoder angle comparator (REAC)

    International Nuclear Information System (INIS)

    Pisani, Marco; Astrua, Milena

    2017-01-01

    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of  ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given. (paper)

  12. Kinoform design with an optimal-rotation-angle method.

    Science.gov (United States)

    Bengtsson, J

    1994-10-10

    Kinoforms (i.e., computer-generated phase holograms) are designed with a new algorithm, the optimalrotation- angle method, in the paraxial domain. This is a direct Fourier method (i.e., no inverse transform is performed) in which the height of the kinoform relief in each discrete point is chosen so that the diffraction efficiency is increased. The optimal-rotation-angle algorithm has a straightforward geometrical interpretation. It yields excellent results close to, or better than, those obtained with other state-of-the-art methods. The optimal-rotation-angle algorithm can easily be modified to take different restraints into account; as an example, phase-swing-restricted kinoforms, which distribute the light into a number of equally bright spots (so called fan-outs), were designed. The phase-swing restriction lowers the efficiency, but the uniformity can still be made almost perfect.

  13. A Vision-Based Dynamic Rotational Angle Measurement System for Large Civil Structures

    Science.gov (United States)

    Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han

    2012-01-01

    In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system. PMID:22969348

  14. 3. Radiotracers

    International Nuclear Information System (INIS)

    Musilek, L.

    1992-01-01

    The chapter deals with basic characteristics of radiotracer methods, with demands placed on radiotracers, their assets and drawbacks, the applicability of the method to the study of laminar flows, and examples of radiotracer applications in biochemistry, metallurgy, in the investigation of the permeation and passage of gases and liquids, in the examination of wear of machine components, and in criminological practice. An overview of the major radionuclides and of radiotracer applications is given. (Z.S.). 3 tabs., 5 figs., 25 refs

  15. Heat transfer from rotating finned heat exchangers with different orientation angles

    Energy Technology Data Exchange (ETDEWEB)

    Tawfik, Adel Abdalla [Suez Canal University, Marine Engineering and Naval Architecture Department, Faculty of Engineering, Port Said (Egypt)

    2010-03-15

    The local and average heat transfer characteristics of spoke like fins that extend outward from a rotating shaft have been determined experimentally. The experiments encompassed a number of geometrical parameters, including the length and chord of the fins, the number of fins deployed around the circumference of the shaft and the orientation angles of the fin. The experiments cover a wider range of rotational speeds, which varies from 25 up to 2,000 rpm. Three wire heat flux sensors have been used in conjunction with a slip ring apparatus to evaluate the local and average heat transfer coefficients. The output results indicated that, the heat transfer transition on rotating fins occurs at Reynolds number lower than encountered on the stationary rectangular fins in crossflow. In general, with non zero incidence angle, the rotating system acts as a fan and creates axial air motion, which enhance the heat transfer rate. However, the effect of orientation angle reduces with increasing the rotational speed. The Nusselt number data are independent of the number of fins in the circumferential array at high rotational speed and are weakly dependent at low Reynolds numbers. To facilitate the use of the results for design, correlations were developed which represent the fin heat transfer coefficient as a continuous function of the investigated independent parameters. (orig.)

  16. Radiotracer methodology

    International Nuclear Information System (INIS)

    Eng, R.R.

    1988-01-01

    In 1923, George Hevesy demonstrated the distribution of radioactive lead in the horsebean plant. This early demonstration of the potential use of radiotracers in biology was reinforced when J.G. Hamilton and colleagues used iodine-131 for diagnostic purposes in patients. Then in 1950 Cassen et al. designed the first scintillation counter for measuring radioiodine in the body, using calcium tungstate crystals coupled to a photomultiplier tube. This was followed by the development of the Anger camera, which permitted visualization of radiotracer distribution in biological systems. From these significant early discoveries to the present, many advances have been made. They include the discovery and production of many useful radioisotopes; the formulation of these radioisotopes into useful radiotracers; the advent of first- , and second-, and third-generation instrumentation for monitoring in vitro and in vivo distributions of new radiotracers; and the application of this knowledge to allow us to better understand physiological processes and treat disease states. Radiotracer techniques are integral to numerous techniques described in this volume. Autoradiography, nuclear scintigraphy, positron emission tomography, and single-photon emission computed tomography (SPECT) are all dependent on an understanding of radiotracer techniques to properly utilize these probe devices

  17. Improving Zernike moments comparison for optimal similarity and rotation angle retrieval.

    Science.gov (United States)

    Revaud, Jérôme; Lavoué, Guillaume; Baskurt, Atilla

    2009-04-01

    Zernike moments constitute a powerful shape descriptor in terms of robustness and description capability. However the classical way of comparing two Zernike descriptors only takes into account the magnitude of the moments and loses the phase information. The novelty of our approach is to take advantage of the phase information in the comparison process while still preserving the invariance to rotation. This new Zernike comparator provides a more accurate similarity measure together with the optimal rotation angle between the patterns, while keeping the same complexity as the classical approach. This angle information is particularly of interest for many applications, including 3D scene understanding through images. Experiments demonstrate that our comparator outperforms the classical one in terms of similarity measure. In particular the robustness of the retrieval against noise and geometric deformation is greatly improved. Moreover, the rotation angle estimation is also more accurate than state-of-the-art algorithms.

  18. Radiotracer in industry

    International Nuclear Information System (INIS)

    Jaafar Abdullah

    2005-01-01

    The use of radiotracers for troubleshooting and to investigate process phenomena in industrial plant equipment has specific advantages over conventional tracers. The main advantages of radiotracers owes to its physico-chemical compatibility, high detection sensitivity, ability of number of radiotracers for different phases, stability in harsh industrial environment and limited memory effects. This chapter covers the methodology which includes the selection of radiotracer, radioisotope generators, estimation of amount of radiotracer, injection systems, detection system and safety procedure. Leak detection, this topic discussed the detection by flowrate measurement, detection of RTD measurement, detection by direct tracer, detection in underground pipes using the static method and dynamic method. The topic namely Radiotracers for flowrate measurement discussed the following subjects: flowrate measurement, transit time methods, dilution methods, standards for flow measurement, multi-phase flow measurement. RTD measurement, this topic covers the basic flow concepts, the mathematical modelling, RTD software, bypassing or channelling, recirculation, trickle bed reactors studies, process diagnosis and analysis. Lastly, the topic cover other application of radiotracers in industry discussed the following subtopics: mixing and blending studies, measurement of volume, ventilation studies, oil field investigation, corrosion and wear studies, validation of CFD models

  19. A correlative study of aortic valve rotation angle and thoracic aortic sizes using ECG gated CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saremi, Farhood, E-mail: fsaremi@usc.edu; Cen, Steven; Tayari, Nazila; Alizadeh, Houman; Emami, Amir; Lin, Leah; Fleischman, Fernando

    2017-04-15

    Objective: Various degrees of aortic valve rotation may be seen in individuals with no history of congenital cardiovascular malformations, but its association with aortic sizes has not been studied. Methods: Gated computed tomographic (CT angiograms in 217 patients were studied (66.7 ± 15; 22–97 years old)). Aortic diameters were determined at 5 anatomic locations. The length of the aorta from sinus to left subclavian artery was measured. The angle of valve rotation was recorded by measuring the angle between a line connecting the midpoint of the non-coronary sinus to the anterior commissure and another line along the interatrial septum. Rotation angles were correlated with aortic measurements. Patients were separated into two groups based on aortic sizes and into three groups based on age. The threshold for aortic dilatation was set at maximum ascending aorta diameter ≥40 mm (≥21 mm body surface area [BSA] indexed). Results: No significant difference in rotation angles was seen between the three age groups or between genders. Rotation angles were significantly correlated with maximal, average, and BSA adjustment of the aortic root and ascending aortic measurements. The aortic root angles were significantly different between the dilated versus nondilated aortas. There was no significant association between the rotation angles and age, length of ascending aorta, or diameters of descending aorta. Multivariate adaptive regression splines showed 25° of aortic root rotation as the diagnostic cut off for ascending aorta dilation. Above the 25° rotation, every 10° of increasing rotation was associated with a 3.78 ± 0.87 mm increase in aortic diameter (p < 0.01) and a 1.73 ± 0.25 times increased risk for having a dilated aorta (p < 0.01). Conclusion: Rotation angles of the aortic valve may be an independent non-invasive imaging marker for dilatation of the ascending aorta. Patients with increased rotation angle of the aortic valve may have higher risk for

  20. Rotational error in path integration: encoding and execution errors in angle reproduction.

    Science.gov (United States)

    Chrastil, Elizabeth R; Warren, William H

    2017-06-01

    Path integration is fundamental to human navigation. When a navigator leaves home on a complex outbound path, they are able to keep track of their approximate position and orientation and return to their starting location on a direct homebound path. However, there are several sources of error during path integration. Previous research has focused almost exclusively on encoding error-the error in registering the outbound path in memory. Here, we also consider execution error-the error in the response, such as turning and walking a homebound trajectory. In two experiments conducted in ambulatory virtual environments, we examined the contribution of execution error to the rotational component of path integration using angle reproduction tasks. In the reproduction tasks, participants rotated once and then rotated again to face the original direction, either reproducing the initial turn or turning through the supplementary angle. One outstanding difficulty in disentangling encoding and execution error during a typical angle reproduction task is that as the encoding angle increases, so does the required response angle. In Experiment 1, we dissociated these two variables by asking participants to report each encoding angle using two different responses: by turning to walk on a path parallel to the initial facing direction in the same (reproduction) or opposite (supplementary angle) direction. In Experiment 2, participants reported the encoding angle by turning both rightward and leftward onto a path parallel to the initial facing direction, over a larger range of angles. The results suggest that execution error, not encoding error, is the predominant source of error in angular path integration. These findings also imply that the path integrator uses an intrinsic (action-scaled) rather than an extrinsic (objective) metric.

  1. Radiotracer aided optimization of batch mixing of solids

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Bergh, W.J.B. van den; Scarlett, B.

    1989-01-01

    A method for the determination of mixing times has been developed and tested in a model Nauta mixer filled with sand. 128 I-labelled sand particles were used as radiotracer and the progress of mixing was monitored with two radiation detectors located externally. The variance of the radiation intensity decreases with time until a constant value is reached indicating an equilibrium mixture of tracer and sand. The time necessary to achieve this condition (mixing time) appears to be dependent on the rotational speed of the hopper as well as the screw of the mixer. Optimal mixing performance (shortest mixing time) corresponds to the maximal rotational speeds of both rotating parts of the mixer. (author)

  2. Effect of the cosmological constant on the deflection angle by a rotating cosmic string

    Science.gov (United States)

    Jusufi, Kimet; Övgün, Ali

    2018-03-01

    We report the effect of the cosmological constant and the internal energy density of a cosmic string on the deflection angle of light in the spacetime of a rotating cosmic string with internal structure. We first revisit the deflection angle by a rotating cosmic string and then provide a generalization using the geodesic equations and the Gauss-Bonnet theorem. We show there is an agreement between the two methods when employing higher-order terms of the linear mass density of the cosmic string. By modifying the integration domain for the global conical topology, we resolve the inconsistency between these two methods previously reported in the literature. We show that the deflection angle is not affected by the rotation of the cosmic string; however, the cosmological constant Λ strongly affects the deflection angle, which generalizes the well-known result.

  3. Full-Angle Quaternions for Robustly Matching Vectors of 3D Rotations

    NARCIS (Netherlands)

    Liwicki, Stephan; Pham, Minh-Tri; Zafeiriou, Stefanos; Pantic, Maja; Stenger, Björn

    In this paper we introduce a new distance for robustly matching vectors of 3D rotations. A special representation of 3D rotations, which we coin full-angle quaternion (FAQ), allows us to express this distance as Euclidean. We apply the distance to the problems of 3D shape recognition from point

  4. The greater tuberosity angle: a new predictor for rotator cuff tear.

    Science.gov (United States)

    Cunningham, Gregory; Nicodème-Paulin, Emilie; Smith, Margaret M; Holzer, Nicolas; Cass, Benjamin; Young, Allan A

    2018-04-24

    The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P rotator cuff tear (P rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  5. Signature of non-isotropic distribution of stellar rotation inclination angles in the Praesepe cluster

    Science.gov (United States)

    Kovacs, Geza

    2018-04-01

    The distribution of the stellar rotation axes of 113 main sequence stars in the open cluster Praesepe are examined by using current photometric rotation periods, spectroscopic rotation velocities, and estimated stellar radii. Three different samples of stellar rotation data on spotted stars from the Galactic field and two independent samples of planetary hosts are used as control samples to support the consistency of the analysis. Considering the high completeness of the Praesepe sample and the behavior of the control samples, we find that the main sequence F - K stars in this cluster are susceptible to rotational axis alignment. Using a cone model, the most likely inclination angle is 76° ± 14° with a half opening angle of 47° ± 24°. Non-isotropic distribution of the inclination angles is preferred over the isotropic distribution, except if the rotation velocities used in this work are systematically overestimated. We found no indication of this being the case on the basis of the currently available data. Data are only available at the CDS, together with the other two compiled datasets used in this paper, via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/612/L2

  6. Femoral rotation unpredictably affects radiographic anatomical lateral distal femoral angle measurements

    DEFF Research Database (Denmark)

    Miles, James Edward

    2016-01-01

    Objective: To describe the effects of internal and external femoral rotation on radiographic measurements of the anatomical lateral distal femoral angle (a-LDFA) using two methods for defining the anatomical proximal femoral axis (a-PFA). Methods: Digital radiographs were obtained of 14 right...... femora at five degree intervals from 10° external rotation to 10° internal rotation. Using freely available software, a-LDFA measurements were made using two different a-PFA by a single observer on one occasion. Results: Mean a-LDFA was significantly greater at 10° external rotation than at any other...... rotation. The response of individual femora to rotation was unpredictable, although fairly stable within ±5° of zero rotation. Mean a-LDFA for the two a-PFA methods differed by 1.5°, but were otherwise similarly affected by femoral rotation. Clinical significance: If zero femoral elevation can be achieved...

  7. Rotation Estimation for Wide-Angle Inverse Synthetic Aperture Radar Imaging

    Directory of Open Access Journals (Sweden)

    Wei Zhou

    2016-01-01

    Full Text Available To present focused ISAR imaging results in the homogenous range and cross-range domain, an integrated scheme is proposed to estimate both the targets equivalent rotational velocity (RV and rotational center (RC. The RV estimation is improved by radial projection combined with keystone processing, and then the RC is estimated through image entropy minimization. Finally, delicate imaging results may be obtained for wide-angle scenarios. Experiment results are provided to demonstrate the effectiveness of the proposed method.

  8. Synthesis of new radiotracers

    International Nuclear Information System (INIS)

    Chahed, Ahlem

    2008-01-01

    The brain's sensibility besides to the rigorous selectivity of changes taking place on brain's barriers leads us to synthesis specifics radiotracers based on diamine ethylene and marked with technetium radioisotope to form a radiotracer able to pass these barriers and diagnose illnesses in an early stage. These radiotracers are tested by a biodistribution on a small animal to be ratified. (Author)

  9. The effects of transverse rotation angle on compression and effective lever arm of prosthetic feet during simulated stance.

    Science.gov (United States)

    Major, Matthew J; Howard, David; Jones, Rebecca; Twiste, Martin

    2012-06-01

    Unlike sagittal plane prosthesis alignment, few studies have observed the effects of transverse plane alignment on gait and prosthesis behaviour. Changes in transverse plane rotation angle will rotate the points of loading on the prosthesis during stance and may alter its mechanical behaviour. This study observed the effects of increasing the external transverse plane rotation angle, or toe-out, on foot compression and effective lever arm of three commonly prescribed prosthetic feet. The roll-over shape of a SACH, Flex and single-axis foot was measured at four external rotation angle conditions (0°, 5°, 7° and 12° relative to neutral). Differences in foot compression between conditions were measured as average distance between roll-over shapes. Increasing the transverse plane rotation angle did not affect foot compression. However, it did affect the effective lever arm, which was maximized with the 5° condition, although differences between conditions were small. Increasing the transverse plane rotation angle of prosthetic feet by up to 12° beyond neutral has minimal effects on their mechanical behaviour in the plane of walking progression during weight-bearing.

  10. Increasing FSW join strength by optimizing feed rate, rotating speed and pin angle

    Science.gov (United States)

    Darmadi, Djarot B.; Purnowidodo, Anindito; Siswanto, Eko

    2017-10-01

    Principally the join in Friction Stir Welding (FSW) is formed due to mechanical bonding. At least there are two factors determines the quality of this join, first is the temperature in the area around the interface and secondly the intense of mixing forces in nugget zone to create the mechanical bonding. The adequate temperature creates good flowability of the nugget zone and an intensive mixing force produces homogeneous strong bonding. Based on those two factors in this research the effects of feed rate, rotating speed and pin angle of the FSW process to the tensile strength of resulted join are studied. The true experimental method was used. Feed rate was varied at 24, 42, 55 and 74 mm/minutes and from the experimental results, it can be concluded that the higher feed rate decreases the tensile strength of weld join and it is believed due to the lower heat embedded in the material. Inversely, the higher rotating speed increases the join’s tensile strength as a result of higher heat embedded in base metal and higher mixing force in the nugget zone. The rotating speed were 1842, 2257 and 2904 RPMs. The pin angle determines the direction of mixing force. With variation of pin angle: 0°, 4°, 8° and 12° the higher pin angle generally increases the tensile strength because of more intensive mixing force. For 12° pin angle the lower tensile strength is found since the force tends to push out the nugget area from the joint gap.

  11. Radiotracers for medical applications

    International Nuclear Information System (INIS)

    Rayudu, G.A.S.

    1983-01-01

    This book discusses the medical applications of radiotracers. Diagnostic uses and pharmacokinetics of isotopes and radiopharmaceuticals is emphasized. The volume one covers the following topics: Radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; /sup 11/C, /sup 13/N, /sup 15/O, /sup 67/Ga. /sup 111/In, /sup 75/Se, /sup 123m/Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented. 272 pp., 7 x 10, 1983, ISBN-0-8493-6016-1

  12. Improper trunk rotation sequence is associated with increased maximal shoulder external rotation angle and shoulder joint force in high school baseball pitchers.

    Science.gov (United States)

    Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B

    2014-09-01

    In a properly coordinated throwing motion, peak pelvic rotation velocity is reached before peak upper torso rotation velocity, so that angular momentum can be transferred effectively from the proximal (pelvis) to distal (upper torso) segment. However, the effects of trunk rotation sequence on pitching biomechanics and performance have not been investigated. The aim of this study was to investigate the effects of trunk rotation sequence on ball speed and on upper extremity biomechanics that are linked to injuries in high school baseball pitchers. The hypothesis was that pitchers with improper trunk rotation sequence would demonstrate lower ball velocity and greater stress to the joint. Descriptive laboratory study. Three-dimensional pitching kinematics data were captured from 72 high school pitchers. Subjects were considered to have proper or improper trunk rotation sequences when the peak pelvic rotation velocity was reached either before or after the peak upper torso rotation velocity beyond the margin of error (±3.7% of the time from stride-foot contact to ball release). Maximal shoulder external rotation angle, elbow extension angle at ball release, peak shoulder proximal force, shoulder internal rotation moment, and elbow varus moment were compared between groups using independent t tests (α ways that may influence injury risk. As such, exercises that reinforce the use of a proper trunk rotation sequence during the pitching motion may reduce the stress placed on the structures around the shoulder joint and lead to the prevention of injuries. © 2014 The Author(s).

  13. Radiotracer properties determined by high performance liquid chromatography: a potential tool for brain radiotracer discovery

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Lewsey, James; Dewar, Deborah; Pimlott, Sally L.

    2012-01-01

    Introduction: Previously, development of novel brain radiotracers has largely relied on simple screening tools. Improved selection methods at the early stages of radiotracer discovery and an increased understanding of the relationships between in vitro physicochemical and in vivo radiotracer properties are needed. We investigated if high performance liquid chromatography (HPLC) methodologies could provide criteria for lead candidate selection by comparing HPLC measurements with radiotracer properties in humans. Methods: Ten molecules, previously used as radiotracers in humans, were analysed to obtain the following measures: partition coefficient (Log P); permeability (P m ); percentage of plasma protein binding (%PPB); and membrane partition coefficient (K m ). Relationships between brain entry measurements (Log P, P m and %PPB) and in vivo brain percentage injected dose (%ID); and K m and specific binding in vivo (BP ND ) were investigated. Log P values obtained using in silico packages and flask methods were compared with Log P values obtained using HPLC. Results: The modelled associations with %ID were stronger for %PPB (r 2 =0.65) and P m (r 2 =0.77) than for Log P (r 2 =0.47) while 86% of BP ND variance was explained by K m . Log P values were variable dependant on the methodology used. Conclusions: Log P should not be relied upon as a predictor of blood-brain barrier penetration during brain radiotracer discovery. HPLC measurements of permeability, %PPB and membrane interactions may be potentially useful in predicting in vivo performance and hence allow evaluation and ranking of compound libraries for the selection of lead radiotracer candidates at early stages of radiotracer discovery.

  14. Role of radiotracer in animal science

    International Nuclear Information System (INIS)

    Sivaprasad, N.

    2015-01-01

    Radiotracers have been used as radiopharmaceuticals for diagnosis and treatment of animal diseases in cattle and pet animals. In fact the veterinary nuclear medicine based on radiotracer as radiopharmaceuticals is established medical technique for functional studies and imaging of vital organs such as heart, lung, brain, spleen, liver, kidney etc for diagnosis as well as treatment of diseases such as cancers in animal. Besides, radiation from radioisotopes has been in use for radiation therapy of cancers in animals. The nuclear imaging using positron emitting radiotracer is gaining importance in the evolution of drug in small animals. In this respect, small animals have also contributed significantly in the development of radiopharmaceuticals particularly for biodistribution and bioscan studies. In fact, the quality control of radiopharmaceuticals in animals to test the safety is a mandatory requirement in the production of radiopharmaceuticals. In brief the animal science has contributed in various areas and facets of radiotracer techniques and its application vice versa the radiotracer techniques have contributed towards the progress of animal science. The animal science in combination with radiotracer has also contributed to the progress of other basic and applied sciences. Thus there exists a bond between radiotracer techniques and animal science. Some aspects of mutual dependence of animal science and radiotracer are elaborated

  15. Development of Radiotracer Techniques in Industry

    International Nuclear Information System (INIS)

    Wardono

    2000-01-01

    Contribution of radiotracer techniques to solve problems in industrial process plants have been recognized since a long time. Radiotracer application was governed by three main components, namely radioisotopes, radiation detection and data interpretation of an experiment. The three main components mentioned above have been continually developed to overcome problems relating to the operation of industrial process plants. The availability of isotope generator is one of the development aspect in radiotracer technique. Radiation hazard in radiotracer experiment may be reduced by applying isotope generator and on the other hand the delivery of radiotracer to the plant site from the radioisotopes producer was made easier. The development of microprocessor in computer system has facilitated data recording, storing and retrieving. Development in mathematical model supported by radiotracer experiment enhance data interpretation and shed light on various phenomena of flow process. Generally a flow dynamic in a process plant in all kind of industries can be studied using radiotracer technique. However the main challenge coming from petroleum, petrochemical and mineral processing industries

  16. A philosophy for CNS radiotracer design.

    Science.gov (United States)

    Van de Bittner, Genevieve C; Ricq, Emily L; Hooker, Jacob M

    2014-10-21

    Decades after its discovery, positron emission tomography (PET) remains the premier tool for imaging neurochemistry in living humans. Technological improvements in radiolabeling methods, camera design, and image analysis have kept PET in the forefront. In addition, the use of PET imaging has expanded because researchers have developed new radiotracers that visualize receptors, transporters, enzymes, and other molecular targets within the human brain. However, of the thousands of proteins in the central nervous system (CNS), researchers have successfully imaged fewer than 40 human proteins. To address the critical need for new radiotracers, this Account expounds on the decisions, strategies, and pitfalls of CNS radiotracer development based on our current experience in this area. We discuss the five key components of radiotracer development for human imaging: choosing a biomedical question, selection of a biological target, design of the radiotracer chemical structure, evaluation of candidate radiotracers, and analysis of preclinical imaging. It is particularly important to analyze the market of scientists or companies who might use a new radiotracer and carefully select a relevant biomedical question(s) for that audience. In the selection of a specific biological target, we emphasize how target localization and identity can constrain this process and discuss the optimal target density and affinity ratios needed for binding-based radiotracers. In addition, we discuss various PET test-retest variability requirements for monitoring changes in density, occupancy, or functionality for new radiotracers. In the synthesis of new radiotracer structures, high-throughput, modular syntheses have proved valuable, and these processes provide compounds with sites for late-stage radioisotope installation. As a result, researchers can manage the time constraints associated with the limited half-lives of isotopes. In order to evaluate brain uptake, a number of methods are available

  17. Knee rotation influences the femoral tunnel angle measurement after anterior cruciate ligament reconstruction: a 3-dimensional computed tomography model study

    Science.gov (United States)

    Tang, Jing; Thorhauer, Eric; Marsh, Chelsea; Fu, Freddie H.

    2013-01-01

    Purpose Femoral tunnel angle (FTA) has been proposed as a metric for evaluating whether ACL reconstruction was performed anatomically. In clinic, radiographic images are typically acquired with an uncertain amount of internal/external knee rotation. The extent to which knee rotation will influence FTA measurement is unclear. Furthermore, differences in FTA measurement between the two common positions (0° and 45° knee flexion) have not been established. The purpose of this study was to investigate the influence of knee rotation on FTA measurement after ACL reconstruction. Methods Knee CT data from 16 subjects were segmented to produce 3D bone models. Central axes of tunnels were identified. The 0° and 45° flexion angles were simulated. Knee internal/external rotations were simulated in a range of ±20°. FTA was defined as the angle between the tunnel axis and femoral shaft axis, orthogonally projected into the coronal plane. Results Femoral tunnel angle was positively/negatively correlated with knee rotation angle at 0°/45° knee flexion. At 0° knee flexion, FTA for anterio-medial (AM) tunnels was significantly decreased at 20° of external knee rotation. At 45° knee flexion, more than 16° external or 19° internal rotation significantly altered FTA measurements for single-bundle tunnels; smaller rotations (±9° for AM, ±5° for PL) created significant errors in FTA measurements after double-bundle reconstruction. Conclusion Femoral tunnel angle measurements were correlated with knee rotation. Relatively small imaging malalignment introduced significant errors with knee flexed 45°. This study supports using the 0° flexion position for knee radiographs to reduce errors in FTA measurement due to knee internal/external rotation. Level of evidence Case–control study, Level III. PMID:23589127

  18. Effect of forearm axially rotated posture on shoulder load and shoulder abduction / flexion angles in one-armed arrest of forward falls.

    Science.gov (United States)

    Hsu, Hsiu-Hao; Chou, You-Li; Lou, Shu-Zon; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2011-03-01

    Falling onto the outstretched hand is the most common cause of upper extremity injury. This study develops an experimental model for evaluating the shoulder load during a simulated forward fall onto one hand with three different forearm axially rotated postures, and examines the shoulder abduction angle and shoulder flexion angle in each case. Fifteen healthy young male subjects with an average age of 23.7 years performed a series of one-armed arrests from a height of 5 cm onto a force plate. The kinematics and kinetics of the upper extremity were analyzed for three different forearm postures, namely 45° externally rotated, non-rotated, and 45° internally rotated. The shoulder joint load and shoulder abduction/flexion angles were significantly dependent on the rotational posture of the forearm. The shoulder medio-lateral shear forces in the externally rotated group were found to be 1.61 and 2.94 times higher than those in the non-rotated and internally rotated groups, respectively. The shoulder flexion angles in the externally rotated, non-rotated and internally rotated groups were 0.6°, 8.0° and 19.2°, respectively, while the corresponding shoulder abduction angles were 6.1°, 34.1° and 46.3°, respectively. In falls onto the outstretched hand, an externally rotated forearm posture should be avoided in order to reduce the medio-lateral shear force acting on the shoulder joint. In falls of this type, a 45° internally rotated forearm posture represents the most effective fall strategy in terms of minimizing the risk of upper extremity injuries. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Anomalous incident-angle and elliptical-polarization rotation of an elastically refracted P-wave

    Science.gov (United States)

    Fa, Lin; Fa, Yuxiao; Zhang, Yandong; Ding, Pengfei; Gong, Jiamin; Li, Guohui; Li, Lijun; Tang, Shaojie; Zhao, Meishan

    2015-08-01

    We report a newly discovered anomalous incident-angle of an elastically refracted P-wave, arising from a P-wave impinging on an interface between two VTI media with strong anisotropy. This anomalous incident-angle is found to be located in the post-critical incident-angle region corresponding to a refracted P-wave. Invoking Snell’s law for a refracted P-wave provides two distinctive solutions before and after the anomalous incident-angle. For an inhomogeneously refracted and elliptically polarized P-wave at the anomalous incident-angle, its rotational direction experiences an acute variation, from left-hand elliptical to right-hand elliptical polarization. The new findings provide us an enhanced understanding of acoustical-wave scattering and lead potentially to widespread and novel applications.

  20. Radiotracer Generators for Industrial Applications

    International Nuclear Information System (INIS)

    2013-01-01

    Radiotracers have been widely used throughout industry to optimize processes, solve problems, improve product quality, save energy and reduce pollution. Their technical, economic and environmental benefits have been recognized by both the industrial and the environmental sectors. The most important radiotracer techniques have been transferred to many developing Member States through IAEA Technical Cooperation projects. However, in spite of their manifest benefits, radiotracer techniques continue to be underutilized, not only by developing countries but also by more industrialized nations. There are a number of factors that restrict the usage of the radioisotope techniques, but chief among them is the timely availability of suitable radiotracers. Ensuring timely availability of suitable radionuclides is a main hurdle to the use of radiotracer techniques in industry. For developing countries that do not possess radioisotope production facilities, the long time required for import of radionuclides not only completely rules out the use of short half-life nuclides, but also makes it impossible for the radioisotope applications teams to respond to problems of an urgent nature. Many possible radiotracer investigations are not being carried out in developing countries because of this problem. Even in industrialized countries, radionuclide supply is often a problem, as many of the former suppliers of industrial radionuclides have switched their production facilities to serve the more lucrative radiopharmaceuticals market. Obtaining continuity of supply of radionuclides with which to carry out extended studies in difficult-to-access locations, such as offshore oil platforms, is also a significant challenge. Making use of tracers from radionuclide generators can alleviate the difficulties associated with radioisotope supply. Two commercially available medical radionuclide generators, 99 Mo/ 99 mTc and 113 Sn/ 113 mIn, have been used for this purpose, but their use has been

  1. Rapid emission angle selection for rotating-shield brachytherapy

    International Nuclear Information System (INIS)

    Liu, Yunlong; Flynn, Ryan T.; Kim, Yusung; Bhatia, Sudershan K.; Sun, Wenqing; Yang Wenjun; Wu Xiaodong

    2013-01-01

    Purpose: The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent TM electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose-volume optimization, with azimuthal shield emission angles of 90°, 180°, and 270°. The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose-volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell-time scaling was applied to all plans such that that high-risk clinical target volume D 90 was maximized without violating the D 2cc tolerances of the rectum, bladder, and sigmoid colon. Results: By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D 90 to 85–100 Gy 10 , the delivery times used by REAS generated plans are 21.0% and 19.5% less than exhaustive surface optimized plans used by the two clinical cases. By setting the delivery time budget to 5–25 and 10–30 min/fx, respectively, for two the cases, the D 90 contributions for REAS are improved by 5.8% and 5.1% compared to the ERSO plans. The ranges used in this comparison were selected in order to keep both D 90 and the delivery time within acceptable limits. Conclusions: The REAS method enables efficient RSBT

  2. The heritage of radiotracers for PET

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1988-01-01

    The history of PET research clearly demonstrates that it is advances in chemistry coupled with a detailed examination of the biochemistry of new radiotracers which has allowed the PET method to be applied to new areas of biology and medicine. Radiotracers whose regional distribution reflects glucose metabolism, neutrotransmitter activity and enzyme activity have all required the development of rapid synthetic methods for the radiotracers themselves and the characterization of their biochemical behavior. This article traces some of the advances in the production of labeled precursors and in radiotracer synthesis and evaluation which have shaped the rapidly expanding application of PET to problems in the neurosciences, in cardiology and in oncology. 54 refs

  3. Leak Detection in Heat Exchangers and Underground Pipelines Using Radiotracers. Material for Education and On-The-Job Training for Practitioners of Radiotracer Technology

    International Nuclear Information System (INIS)

    2009-01-01

    The International Atomic Energy Agency plays a major role in facilitating the transfer of radiotracer technology to developing Member States. The use of radiotracer techniques is well established in many Member States; some hundred radiotracer and end user specialists have been trained in radiotracer techniques and their applications; nearly 50 radiotracer laboratories have been working in this field. The training of radiotracer practitioners is vital for the provision of quality services to industry. Leak detection using radiotracer techniques is probably one of the most widespread applications of radiotracers in industrial troubleshooting. Radiotracer techniques are the most competitive for online leak inspection of heat exchangers and buried pipelines. Radiotracers help in early detection of leaks in heat exchangers and underground transporting pipelines, thus saving money, reducing shutdown time, ensuring safe operation and protecting the environment from pollution. The training course series on leak detection in heat exchangers and underground pipelines using radiotracers addresses the needs of the radiotracer groups and their end users. Besides training purposes, this material will assist radiotracer groups in establishing their quality control and accreditation systems. This training course material is based on lecture notes and practical work delivered by many experts in IAEA-supported activities. In particular, the Technical Cooperation Projects implemented under the Regional Cooperative Agreement (RCA) of the IAEA Member States in the Asia and the Pacific Region have been successful in transferring and implementing radiotracer techniques for leak detection to many end users from oil and gas production, oil refineries and the petrochemical industry. The experience obtained in the RCA Region is presented in the training material illustrated with many case studies carried out in several RCA Member States. Lectures and case studies were reviewed by a number

  4. Comparing non-invasive scapular tracking methods across elevation angles, planes of elevation and humeral axial rotations.

    Science.gov (United States)

    Grewal, T-J; Cudlip, A C; Dickerson, C R

    2017-12-01

    Altered scapular motions premeditate shoulder impingement and other musculoskeletal disorders. Divergent experimental conditions in previous research precludes rigorous comparisons of non-invasive scapular tracking techniques. This study evaluated scapular orientation measurement methods across an expanded range of humeral postures. Scapular medial/lateral rotation, anterior/posterior tilt and protraction/retraction was measured using an acromion marker cluster (AMC), a scapular locator, and a reference stylus. Motion was captured using reflective markers on the upper body, as well as on the AMC, locator and stylus. A combination of 5 arm elevation angles, 3 arm elevation planes and 3 arm axial rotations was examined. Measurement method interacted with elevation angle and plane of elevation for all three scapular orientation directions (p planes and axial rotations. The AMC underestimated lateral rotation, with the largest difference of ∼2° at 0° elevation. Both the locator and AMC overestimated posterior tilt at high arm elevation by up to 7.4°. Misestimations from using the locator could be enough to potentially obscure meaningful differences in scapular rotations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Radiotracer injector: An Industrial Application (RIIA)

    International Nuclear Information System (INIS)

    Noraishah Othman; Mohd Arif Hamzah; Fadil Ismail; Nurliyana Abdullah

    2011-01-01

    The radiotracer injector is meant for transferring liquid radiotracer in the system for industrial radiotracer application with minimal radiation exposure to the operator. The motivation of its invention is coming from the experience of the workers who are very concern about the radiation safety while handling with the radioactive source. The idea ensuring the operation while handling the radioactive source is fast and safe without interrupting the efficiency and efficacy of the process. Thus, semi automated device assisting with pneumatic technology is applied for its invention. (author)

  6. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  7. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  8. Lumbar lordosis angle and trunk and lower-limb electromyographic activity comparison in hip neutral position and external rotation during back squats.

    Science.gov (United States)

    Oshikawa, Tomoki; Morimoto, Yasuhiro; Kaneoka, Koji

    2018-03-01

    [Purpose] To compare the lumbar lordosis angle and electromyographic activities of the trunk and lower-limb muscles in the hip neutral position and external rotation during back squats. [Subjects and Methods] Ten healthy males without severe low back pain or lower-limb injury participated in this study. The lumbar lordosis angle and electromyographic activities were measured using three-dimensional motion-capture systems and surface electrodes during four back squats: parallel back squats in the hip neutral position and external rotation and full back squats in the hip neutral position and external rotation. A paired t-test was used to compare parallel and full back squats measurements in the hip neutral position and external rotation, respectively. [Results] During parallel back squats, the average lumbar lordosis angle was significantly larger in hip external rotation than in the hip neutral position. During full back squats, lumbar erector spinae and multifidus activities were significantly lower in hip external rotation than in the hip neutral position, whereas gluteus maximus activity was significantly higher in hip external rotation than in the hip neutral position. [Conclusion] The back squat in hip external rotation induced improvement of lumbar kyphosis, an increasing of the gluteus maximus activity and a decrease of both lumbar erector spinae and multifidus activities.

  9. Radiotracers in medical applications, vols 1-2

    International Nuclear Information System (INIS)

    Rayudu, G.V.S.

    1983-01-01

    These volumes will serve as a basis for instruction and reference for professionals such as radiopharmaceutical chemists, radiopharmacologists, radiopharmacists, radiobiochemists, and others involved in the medical applications of radiotracers. Vol. I: Topics include radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; 11 C, 13 N, 15 O, 67 Ga. 111 In, 75 Se, /SUP 123m/ Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented

  10. Analytical calculations of the rotational transform angles in the torsatron systems with different plasma pressure profiles

    International Nuclear Information System (INIS)

    Kuznetsov, Yu.K.; Pinos, I.B.; Tyupa, V.I.

    1999-01-01

    With formulas for averaging over magnetic surfaces general analytical expressions are here deduced to determine the rotational transform angles in stellarator systems having different plasma pressure profiles

  11. Effects of pelvic rotation and needle angle on pubic arch interference during transperineal prostate implants

    International Nuclear Information System (INIS)

    Tincher, Sandra A.; Kim, Robert Y.; Ezekiel, Mark P.; Zinsli, Tom; Fiveash, John B.; Raben, David A.; Bueschen, Anton J.; Urban, Donald A.

    2000-01-01

    Purpose: Pubic arch interference due to an enlarged prostate gland or a narrow pubic arch is often a limiting factor in adequate prostate coverage during transperineal brachytherapy. The purpose of this study was to evaluate the effects of both pelvic rotation and needle angles on pubic arch interference using CT-based 3-D information. Methods and Materials: Seven patients had CT imaging in both supine and lithotomy positions and 3-D treatment planning was performed with three needle angles (20 downward, 0, 20 upward). The pubic arch interference was then measured and comparisons were made for each needle trajectory and pelvic position. Results: Increasing pelvic rotation from supine to lithotomy position shows less pubic arch interference. Directing the needle tip upward shows less pubic arch interference in both supine and lithotomy positions when compared to needle tips directed downward. Conclusions: Both pelvic position and needle angles are important factors influencing pubic arch interference. Preplanning CT-based 3-D information may assist for individualized treatment planning in patients with a significant bony interference, thus avoiding pubic arch interference during implantation

  12. Effect of shoulder abduction angle on biomechanical properties of the repaired rotator cuff tendons with 3 types of double-row technique.

    Science.gov (United States)

    Mihata, Teruhisa; Fukuhara, Tetsutaro; Jun, Bong Jae; Watanabe, Chisato; Kinoshita, Mitsuo

    2011-03-01

    After rotator cuff repair, the shoulder is immobilized in various abduction positions. However, there is no consensus on the proper abduction angle. To assess the effect of shoulder abduction angle on the biomechanical properties of the repaired rotator cuff tendons among 3 types of double-row techniques. Controlled laboratory study. Thirty-two fresh-frozen porcine shoulders were used. A simulated rotator cuff tear was repaired by 1 of 3 double-row techniques: conventional double-row repair, transosseous-equivalent repair, and a combination of conventional double-row and bridging sutures (compression double-row repair). Each specimen underwent cyclic testing followed by tensile testing to failure at a simulated shoulder abduction angle of 0° or 40° on a material testing machine. Gap formation and failure loads were measured. Gap formation in conventional double-row repair at 0° (1.2 ± 0.5 mm) was significantly greater than that at 40° (0.5 ± 0.3mm, P = .01). The yield and ultimate failure loads for conventional double-row repair at 40° were significantly larger than those at 0° (P row repair (P row repair was the greatest among the 3 double-row techniques at both 0° and 40° of abduction. Bridging sutures have a greater effect on the biomechanical properties of the repaired rotator cuff tendon at a low abduction angle, and the conventional double-row technique has a greater effect at a high abduction angle. Proper abduction position after rotator cuff repair differs between conventional double-row repair and transosseous-equivalent repair. The authors recommend the use of the combined technique of conventional double-row and bridging sutures to obtain better biomechanical properties at both low and high abduction angles.

  13. Dynamic-angle spinning and double rotation of quadrupolar nuclei

    International Nuclear Information System (INIS)

    Mueller, K.T.; California Univ., Berkeley, CA

    1991-07-01

    Nuclear magnetic resonance (NMR) spectroscopy of quadrupolar nuclei is complicated by the coupling of the electric quadrupole moment of the nucleus to local variations in the electric field. The quadrupolar interaction is a useful source of information about local molecular structure in solids, but it tends to broaden resonance lines causing crowding and overlap in NMR spectra. Magic- angle spinning, which is routinely used to produce high resolution spectra of spin-1/2 nuclei like carbon-13 and silicon-29, is incapable of fully narrowing resonances from quadrupolar nuclei when anisotropic second-order quadrupolar interactions are present. Two new sample-spinning techniques are introduced here that completely average the second-order quadrupolar coupling. Narrow resonance lines are obtained and individual resonances from distinct nuclear sites are identified. In dynamic-angle spinning (DAS) a rotor containing a powdered sample is reoriented between discrete angles with respect to high magnetic field. Evolution under anisotropic interactions at the different angles cancels, leaving only the isotropic evolution of the spin system. In the second technique, double rotation (DOR), a small rotor spins within a larger rotor so that the sample traces out a complicated trajectory in space. The relative orientation of the rotors and the orientation of the larger rotor within the magnetic field are selected to average both first- and second-order anisotropic broadening. The theory of quadrupolar interactions, coherent averaging theory, and motional narrowing by sample reorientation are reviewed with emphasis on the chemical shift anisotropy and second-order quadrupolar interactions experienced by half-odd integer spin quadrupolar nuclei. The DAS and DOR techniques are introduced and illustrated with application to common quadrupolar systems such as sodium-23 and oxygen-17 nuclei in solids

  14. Dynamic-angle spinning and double rotation of quadrupolar nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, K.T. (Lawrence Berkeley Lab., CA (United States) California Univ., Berkeley, CA (United States). Dept. of Chemistry)

    1991-07-01

    Nuclear magnetic resonance (NMR) spectroscopy of quadrupolar nuclei is complicated by the coupling of the electric quadrupole moment of the nucleus to local variations in the electric field. The quadrupolar interaction is a useful source of information about local molecular structure in solids, but it tends to broaden resonance lines causing crowding and overlap in NMR spectra. Magic- angle spinning, which is routinely used to produce high resolution spectra of spin-{1/2} nuclei like carbon-13 and silicon-29, is incapable of fully narrowing resonances from quadrupolar nuclei when anisotropic second-order quadrupolar interactions are present. Two new sample-spinning techniques are introduced here that completely average the second-order quadrupolar coupling. Narrow resonance lines are obtained and individual resonances from distinct nuclear sites are identified. In dynamic-angle spinning (DAS) a rotor containing a powdered sample is reoriented between discrete angles with respect to high magnetic field. Evolution under anisotropic interactions at the different angles cancels, leaving only the isotropic evolution of the spin system. In the second technique, double rotation (DOR), a small rotor spins within a larger rotor so that the sample traces out a complicated trajectory in space. The relative orientation of the rotors and the orientation of the larger rotor within the magnetic field are selected to average both first- and second-order anisotropic broadening. The theory of quadrupolar interactions, coherent averaging theory, and motional narrowing by sample reorientation are reviewed with emphasis on the chemical shift anisotropy and second-order quadrupolar interactions experienced by half-odd integer spin quadrupolar nuclei. The DAS and DOR techniques are introduced and illustrated with application to common quadrupolar systems such as sodium-23 and oxygen-17 nuclei in solids.

  15. Radiotracer Applications in Wastewater Treatment Plants

    International Nuclear Information System (INIS)

    2011-01-01

    Wastewater containing pollutants resulting from municipal and industrial activities are normally collected in wastewater treatment plants (WWTPs) for processing before discharge to the environment. The WWTPs are the last barrier against contamination of downstream surface waters such as rivers, lakes and sea. Treated wastewater is reused for irrigation, particularly in arid and semi-arid countries. Therefore, it is very important to maintain optimal operating conditions of WWTPs to eliminate or reduce environmental pollution. Wastewater treatment plants are complicated systems, where the processes of mixing, separation, aeration, biological and chemical reactions occur. A WWTP is basically a multiphase system, and the efficiency of an installation strongly depends on liquid, solid and gas phase flow structures and their residence time distributions (RTDs). However, the fluid dynamic properties of such systems are not yet completely understood, rendering difficult the theoretical prediction of important process parameters such as flow rates, phase distributions, mixing and sediment characteristics. Tracer techniques are very useful tools to investigate the efficiency of purification in WWTPs, aiding both their design and performance optimization. There are many kinds of tracers. Radioactive tracers are the most sensitive and are largely used for on-line diagnosis of various operations in WWTPs. The success of radiotracer applications rests upon their extremely high detection sensitivity, and the strong resistance against severe process conditions. During the last few decades, many radiotracer studies have been conducted worldwide for investigation of various installations for wastewater treatment, such as mixer, aeration tank, clarifiers, digester, filter, wetland and oxidation units. Various radiotracer methods and techniques have been developed by individual tracer groups. However, the information necessary for the preservation of knowledge and transfer of

  16. Quality control and analysis of radiotracer compounds

    International Nuclear Information System (INIS)

    Sheppard, G.; Thomson, R.

    1977-01-01

    Special emphasis was on the problems and errors possible in quality control and analysis. The principles underlying quality control were outlined, and analytical techniques applicable to radiotracers were described. Chapter concluded with a selection of examples showing the effects of impurities on the use of radiotracers. The subject of quality control and analysis was treated from the viewpoint of the user and those research workers who need to synthesize and analyze their own radiochemicals. The quality characteristics for radiotracers are of two kinds, valuable or attributive. These were discussed in the chapter. For counting low radioactive concentration, scintillation techniques are in general use, whereas ionization techniques are now used mainly for the measurement of high radioactive concentrations or large quantities of radioactivity, for scanning chromatograms, and a number of very specific purposes. Determination of radionuclidic purity was discussed. Use of radiotracers in pharmaceuticals were presented. 4 figures, 6 tables

  17. Modified small angle magnetization rotation method in multilayer magnetic microwires

    International Nuclear Information System (INIS)

    Torrejon, J.; Badini, G.; Pirota, K.; Vazquez, M.

    2007-01-01

    The small angle magnetization rotation (SAMR) technique is a widely used method to quantify magnetostriction in elongated ultrasoft magnetic materials. In the present work, we introduce significant optimization of the method, particularly simplification of the required equipment, profiting of the very peculiar characteristics of a recently introduced family of multilayer magnetic microwires consisting of a soft magnetic core, insulating intermediate layer and a hard magnetic outer layer. The introduced modified SAMR method is used not only to determine the saturation magnetostriction constant of the soft magnetic nucleus but also the magnetoelastic and magnetostatic coupling. This new method has a great potential in multifunctional sensor applications

  18. Radiotracer injections through microfilters

    International Nuclear Information System (INIS)

    Huber, H.; Maschek, G.; Pichler, R.; Giesen, I.; Hatzl-Griesenhofer, M.; Maschek, W.

    2002-01-01

    Full text: Problems with the injection of radiotracers ( 99m Tc-HAMS, 99m Tc-DPD) to infants when administered through polar-filter-protected venous pathways caused us to get a closer look of what happens to a tracer in such a system. We simulated injections of the tracers mainly used at our institution in an in-vitro array and measured full and empty tracer syringes, filters (0.2 μm micropores) and the post-filter receptacle of the radioactivity. We calculated the percentage of filter-trapped activity and of activity in the receptacle. For several tracers we repeated this process with a neutral filter of the same pore size to get a comparison between the behavior in polarized and electrically inert filters. In general injection of a soluble radiotracer through a polar filter system means a dose loss in the filter of about 10 %, up to the tracer molecule size of IgG-antibodies. Suspended tracers, which consist of comparatively large particles, like RES- or pulmonary perfusion markers, are blocked by the filter, as can be foreseen with a particle size of >> 0.2 μm. DMSA and DPD (a biphosphonate), although both being soluble and rather small molecules, were blocked by the polar filter to a high extent, and by the neutral filter to a much lower, almost neglectable degree. The conclusions are: if possible avoid any use of a filter in your tracer injection pathway. Never use a filter with bone scan or DMSA applications. When doing uptake calculations you have to add the filter counts to the empty syringe value in the formula. If you cannot avoid to inject the radiotracer through a filter you have to replace the filter afterwards and treat the used filter as radioactive waste. The polarity of the filter material might severely affect retention of radiotracer in the filter. (author)

  19. Research reactors serving the radiotracer technique: An overlooked opportunity?

    International Nuclear Information System (INIS)

    Bode, P.

    2010-01-01

    The unique features of using radiotracers are not always fully explored at nuclear research reactor centers. The radiotracer method is a versatile and powerful tool in the study of a wide variety of applications in e.g. chemistry, biology, agriculture, medicine and (industrial) technology. The big advantage of radiotracers above e.g. stable isotope tracers, commonly applied in e.g. nutritional studies, is that radiotracers allow for non-invasive studies of both steady-state and dynamic systems, in equilibrium situations and for transport and exchange phenomena and thus provide information on the chemical and/or physical status of elements. The radiotracer method does not imply huge equipment investments but rather requires that the four interrelated aspects: experimental designs, data treatment including tracer kinetic analysis and data interpretation are careful considered. Radiotracer production with reactors often implies additional fundamental research to use smart nuclear reactions and chemical separations so as to obtain an almost no-carrier added tracer. Nuclear analytical groups, already equipped with gamma-ray spectrometers, can thus extend their research program. Using Ge-spectrometers, multi-labeling experiments are possible which allow for unique applications if different radionuclides exist for the same element, such as 65 Zn and 69m Zn or 64 Cu and 67 Cu. The developments in novel scintillation detectors, room-temperature semiconductor detectors (like CdZnTe) and position-sensitive detectors open the door for an entire new scope of radiotracer applications, such as SPECT. Once applied to in-vitro studies with cell cultures, the nuclear analytical group may position itself into the worlds of medical research, biochemistry and biotechnology. Radiotracers can be used to study the properties of drug-delivering compounds as used in e.g, cancer therapy. Radiotracers can be added as a label to solid particles, to liquids but may also be applied in the

  20. Radiological protection in the use of radiotracers in industrial process

    International Nuclear Information System (INIS)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Thomé, Z.D.

    2017-01-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  1. Radiological protection in the use of radiotracers in industrial process

    Energy Technology Data Exchange (ETDEWEB)

    Costa, M.L L.; Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C., E-mail: mara@cnen.gov.br, E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The use of radiotracers plays an important role to provide methods to optimize industrial process and improve product quality. An increase in the use of radiotracers investigations has been observed in Brazil, however, as there is no specific standard for the licensing of these facilities, generic radiation protection regulations have been used, but these are not comprehensive or technically suitable for this purpose. Regulatory inspections in radiotracer facilities have reported failures in disagreement with best practices for radiological safety, mainly in radioactive waste management and in the control of workplaces during radiotracer injections. In this work, an assessment of radiological protection aspects of radioactive tracers is performed, based on the licensing process of radiotracers facilities, as well as the experience of regulatory inspections and a review of international standards, pointing out relevant radiation safety aspects for working practices, procedures and protective measures before, during and after injections of radioactive tracers, in order to contribute to the future development of specific safety regulations on radiotracers in Brazil. (author)

  2. Synthesis of new technetium brain radiotracers

    International Nuclear Information System (INIS)

    Ben Dhieb, Fatma

    2012-01-01

    The scintigraphic diagnosis is a major mean for detecting neuro degenerative diseases at early stage; this requires specific radiotracers to a particular class of brain receptors. Our goal was the synthesis of radiotracers, cytectrenes derivatives, which are specific to the 5-HT1A receptor, whose dysfunction is an indicator of neuro degeneration. The study of their biodistribution revealed for only one of them, a good brain retention and a retrieval adequate for diagnosis.

  3. Radiotracers inside the system

    International Nuclear Information System (INIS)

    Savio, Eduardo

    2000-01-01

    The radioactive use of a tracer that you incorporated in a biological, physical or chemicals system can be an indicator of some of the following situations: of the system in general, of a property that is wanted to evaluate, of a biochemical, physiological or pathophysiological. One the radiotracers use inside the system presents the following advantages: 1. it is possible to detect them and to measure them with high precision and sensibility, 2. the radioactivity is independent of the pressure, the temperature, the physical or chemical state 3. the radiotracers do affect the system and they can be used as non destructive methods 4. In most of the cases they can be measured in independent form of the matrix, without necessity of a calibration curve

  4. Increase of rotation angle of soil layers during plow operation

    Science.gov (United States)

    Vasilenko, VV; Afonichev, D. N.; Vasilenko, S. V.; Khakhulin, A. N.

    2018-03-01

    One of the advantages of plowing is the ability of the plow to hide the weed seeds deep into the soil. The depth of the embankment exceeds 10-12 cm, from there the weeds can not rise to the surface of the soil. They perish halfway. But for this, it is necessary to wrap the soil layers at an angle close to 180 °. Modern ploughs can not turn the layers of soil at an angle of more than 135 °, therefore the plow is required to be equipped with additional working elements. The aim of the study is to create an adaptation to the plow to expand the furrow before laying the next soil layer. In a wide furrow, the formation will completely tip, the previous layer will not interfere with it. The device is a set of vertical shields. Each shield is fixed behind the working body of the plow. It is installed with an angle of attack of 20-25 ° to move the previous layer to expand the furrow by 10-12 cm. The model and industrial samples of the plow have shown improved agrotechnical indicators. The average angle of the formation rotation was 177 °, the burial of plant residues in the soil increased from 61 to 99%. The field surface with blocks more than 5 cm decreased from 36.3 to 13.4%, the height of the ridges decreased from 7 to 4 cm. The force of soil pressure on the shield was measured by a strain gage. It is 130-330 N depending on the depth of processing and the speed of movement. The increase in power costs for the four-hull plow was 190-750 W. The coulters on the plow are unnecessary, and this saves energy more than its increase for shields.

  5. Rotating-coil calibration in a reference quadrupole, considering roll-angle misalignment and higher-order harmonics

    CERN Document Server

    AUTHOR|(CDS)2075492; Buzio, Marco; Köster, Oliver; Russenschuck, Stephan; Severino, Giordana

    2016-01-01

    A method is proposed for calibrating the radius of a rotating coil sensor by relaxing the metrological constraints on alignment and field errors of the reference quadrupole. A coil radius calibration considering a roll-angle misalignment of the measurement bench, the magnet, and the motor-drive unit is analyzed. Then, the error arising from higher-order harmonic field imperfections in the reference quadrupole is assessed. The method is validated by numerical field computation for both the higher-order harmonic errors and the roll-angle misalignment. Finally, an experimental proof-of-principle demonstration is car-ried out in a calibration magnet with sextupole harmonic.

  6. Principles of radiotracer methodology

    Energy Technology Data Exchange (ETDEWEB)

    Kisieleski, W.E.

    1975-06-01

    Information is presented on the properties of radioisotopes and radiations, methods and equipment for radiation detection, safety in handling radioactive materials, the biological effects of radiation, and the design of radiotracer studies. (LCL)

  7. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    Science.gov (United States)

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  8. The critical shoulder angle is associated with osteoarthritis in the shoulder but not rotator cuff tears

    DEFF Research Database (Denmark)

    Bjarnison, Arnar O; Sørensen, Thomas J; Kallemose, Thomas

    2017-01-01

    BACKGROUND: In 2013 Moor et al introduced the concept of the critical shoulder angle (CSA) and suggested that an abnormal CSA was a leading factor in development of rotator cuff tear (RCT) and osteoarthritis (OA) of the shoulder. This study assessed whether the CSA was associated with RCT and OA...

  9. Radiotracer residence time distribution method for industrial and environmental applications. Material for education and on-the-job training for practitioners of radiotracer technology

    International Nuclear Information System (INIS)

    2008-01-01

    The International Atomic Energy Agency (IAEA) plays a major role in facilitating the transfer of the radiotracer technology to developing Member States. The major radiotracer techniques have been implemented through IAEA technical cooperation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for the education of specialists in different fields of nuclear technologies. This training course material is intended for the cultivation of radiotracer specialists and for continuing technical education of radiotracer practitioners worldwide. The wide interest in radiotracer technology has created the need for high level professional education and training in this field, which are not necessarily covered by traditional university courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Besides educational purposes, this publication will assist developing Member States in establishing their quality control and accreditation systems. This publication is based on lecture notes and practical works delivered by many experts in IAEA-supported activities. Lectures, papers, case studies and software were reviewed by a number of specialists in several meetings

  10. Utility of radiotracer methodology in scientific research of industrial relevancy

    International Nuclear Information System (INIS)

    Kolar, Z.I.

    1990-01-01

    Utilization of radiotracer methodology in industrial research provides substantial scientific rather than directly demonstrable economic benefits. These benefits include better understanding of industrial processes and subsequently the development of new ones. Examples are given of the use of radiotracers in technological studies and the significance of the obtained results is put down. Creative application of radiotracer methodology may contribute to the economic development and technological advancement of all countries including the developing ones. (orig.) [de

  11. Creation of the {pi} angle standard for the flat angle measurements

    Energy Technology Data Exchange (ETDEWEB)

    Giniotis, V; Rybokas, M, E-mail: gi@ap.vtu.l, E-mail: MRybokas@gama.l [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40 (Lithuania)

    2010-07-01

    Angle measurements are based mainly on multiangle prisms - polygons with autocollimators, rotary encoders for high accuracy and circular scales as the standards of the flat angle. Traceability of angle measurements is based on the standard of the plane angle - prism (polygon) calibrated at an appropriate accuracy. Some metrological institutions have established their special test benches (comparators) equipped with circular scales or rotary encoders of high accuracy and polygons with autocollimators for angle calibration purposes. Nevertheless, the standard (etalon) of plane angle - polygon has many restrictions for the transfer of angle unit - radian (rad) and other units of angle. It depends on the number of angles formed by the flat sides of the polygon that is restricted by technological and metrological difficulties related to the production and accuracy determination of the polygon. A possibility to create the standard of the angle equal to {pi} rad or half the circle or the full angle is proposed. It can be created by the circular scale with the rotation axis of very high accuracy and two precision reading instruments, usually, photoelectric microscopes (PM), placed on the opposite sides of the circular scale using the special alignment steps. A great variety of angle units and values can be measured and its traceability ensured by applying the third PM on the scale. Calibration of the circular scale itself and other scale or rotary encoder as well is possible using the proposed method with an implementation of {pi} rad as the primary standard angle. The method proposed enables to assure a traceability of angle measurements at every laboratory having appropriate environment and reading instruments of appropriate accuracy together with a rotary table with the rotation axis of high accuracy - rotation trajectory (runout) being in the range of 0.05 {mu}m. Short information about the multipurpose angle measurement test bench developed is presented.

  12. Large Critical Shoulder Angle Has Higher Risk of Tendon Retear After Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Li, Hong; Chen, Yuzhou; Chen, Jiwu; Hua, Yinghui; Chen, Shiyi

    2018-05-01

    The critical shoulder angle (CSA) is the angle created between the superior and inferior bone margins of the glenoid and the most lateral border of the acromion. A few studies recently investigated the relation between CSA and functional outcomes after rotator cuff repair. However, there is a lack of research investigating the effect of CSA on postoperative tendon integrity after rotator cuff repair. To assess the effects of the CSA on postoperative tendon integrity after rotator cuff repair. Cohort study; Level of evidence, 3. All patients who underwent rotator cuff repair for full-thickness supraspinatus tears by 1 senior surgeon between January 2010 and January 2014 were included in this study. All patients had standardized anteroposterior shoulder radiographs the day before surgery. CSA and acromial index (AI) were measured. AI was derived by measuring the distance from the glenoid plane to the lateral border of the acromion and dividing it by the distance from the glenoid plane to the lateral aspect of the humeral head. Functional scores-including American Shoulder and Elbow Surgeons shoulder evaluation form, modified University of California at Los Angeles score, Constant-Murley score, and visual analog scale for pain-were used to evaluate shoulder function at a minimum follow-up of 2 years. Meanwhile, magnetic resonance imaging examinations were performed to evaluate rotator cuff integrity according to the Sugaya method and the signal/noise quotient (SNQ) of the rotator cuff tendon. A total of 90 patients were included in this study: 42 patients with a single-row repair and 48 with a double-row repair. There was a significant positive correlation between CSA or AI and tendon SNQ. On the basis of CSA, the patients were divided into 2 groups: large CSA (>38°) and control (CSA ≤38°). At final follow-up, the large CSA group and the control CSA group demonstrated no significant differences in American Shoulder and Elbow Surgeons, University of California at

  13. Industrial applications of radiotracers in Indonesia

    International Nuclear Information System (INIS)

    Wandowo

    1994-01-01

    Applications of isotopes and radiation have been developed since 1970 at the Centre for Application of Isotopes and Radiation, National Atomic Energy Agency or BATAN. The scope of applications cover various fields, namely, agriculture, medicine, hydrology, sedimentology and industry. The use of radiotracers prove to be very beneficial for problem solving in industrial process plants and this technique will continuously be promoted by BATAN to industries in Indonesia. Several examples of radiotracer applications in industries which have been carried out by the Group of Industry of the Centre for Application of Isotopes and Radiation are presented. (author). 7 refs., 4 figs., 1 tab

  14. Use of Radiotracers to Study Surface Water Processes

    International Nuclear Information System (INIS)

    2015-03-01

    This publication represents a sound knowledge base for the conduct of radiotracer studies in the environment, with papers on radiotracer methodology, radiation protection and regulation, data analysis and modelling. Environmental case histories from five Member States - Australia, Brazil, France, the Republic of Korea and Sweden - provide information on conducting studies involving he use of radioactive tracers. These case histories are not meant as guidelines for preparing a field study but can rather serve as examples of the type, caution and extent of work involved in environmental studies using radiotracers. This publication can provide guidance for conducting potential future training events in the use of radioactive traces in the environment and can serve as a key reference to all concerned directly with surface water processes

  15. Radiotracer investigations for sediment transport in ports of India

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Goswami, Sunil; Singh, Gursharan

    2013-01-01

    The knowledge of mixing and transport of sediments in coastal region is of vital importance for evaluating suitability of dumping site for dredged sediments produced during maintenance of shipping channels, expansion of existing projects and construction of new projects. Gamma-emitting radiotracers are commonly used for investigation of movement of sediments on seabed using Scandium-46 (scandium glass powder) as radiotracer. The radiotracer is injected on seabed at a desired location and its movement followed over a period of time using waterproof NaI(Tl) scintillation detectors. The recorded data is analyzed to obtain transport parameters and utilized for assessing the suitability of the dumping sites and optimization of the dredging operations. About 70 large-scale investigations have been carried out in different ports in India leading to significant economical benefits to the Ports. Present paper discusses various aspects of the radiotracer technique for sediment transport, methodology of data analysis and a specific case study. (author)

  16. Fostering the local production and application of industrial radiotracers in developing countries - IAEA's role

    International Nuclear Information System (INIS)

    Mohammad Haji-Saeid, S.; Jin, Joon-Ha; Ramamoorthy, Natesan; )

    2006-01-01

    Radiotracer techniques provide fast and accurate information for solving various process problems in industrial plants. The IAEA is playing an important role in supporting the development and transfer of radiotracer techniques to developing countries. The IAEA has implemented 5 coordinated research projects (CRP), including two on-going projects, in the field of radiotracer and sealed source applications in industry. The CRPs facilitated the acquisition and dissemination of know-how and technology for wear/corrosion measurement, residence time: distribution (RTD) study, validation of computed fluid dynamics data, industrial process tomography and inter-well connectivity study. A number of technical cooperation projects have been executed to strengthen the capability of radiotracer groups in developing Member States and to create awareness in the industries about the technical and economical benefits of radiotracer technology. The IAEA's regional projects have strongly impacted the transfer and adoption of the techniques. The status of radiotracer use in developing countries reveals that the lack of timely availability of radiotracers as one of the major problems. Development of some radionuclide generators is a possible solution. Cooperation among the international radiotracer communities is necessary to enhance the availability and use of radiotracers in developing countries. (author)

  17. Biodistribution of gyroxin using 125I as radiotracer

    International Nuclear Information System (INIS)

    Alves da Silva, J.A.; Ribela, M.T.C.P.; Rogero, J.R.; Camillo, M.A.P.; Muramoto, E.

    2006-01-01

    The use of radiotracers in the research of animal venom has been scarce, although it allows an excellent approach to follow the process of bioavailability, biodistribution and kinetics of toxins. The purpose of this study was to assess gyroxin action mechanism, transport, compartments and action sites. This toxin is a thrombin-like and causes the barrel rotation syndrome. The gyroxin was labeled with 125 I and used as a tracer for the in vivo assay in mice. Blood samples and organs were collected at different time intervals, weighed and analyzed in a gamma-counter. The data was related with tissues distribution of protease activated receptor (PAR). Biodistribution assay allowed dividing the organs into three groups. The first one with the organs that followed the blood kinetics, the second with the organs related to metabolisms and elimination, and the third with the organs in which the gyroxin concentration increased during the observation period. (author)

  18. Flow Rate Measurement in Multiphase Flow Rig: Radiotracer and Conventional

    International Nuclear Information System (INIS)

    Nazrul Hizam Yusoff; Noraishah Othman; Nurliyana Abdullah; Amirul Syafiq Mohd Yunos; Rasif Mohd Zain; Roslan Yahya

    2015-01-01

    Applications of radiotracer technology are prevalent throughout oil refineries worldwide, and this industry is one of the main users and beneficiaries of the technology. Radioactive tracers have been used to a great extent in many applications i.e. flow rate measurement, RTD, plant integrity evaluation and enhancing oil production in oil fields. Chemical and petrochemical plants are generally continuously operating and technically complex where the radiotracer techniques are very competitive and largely applied for troubleshooting inspection and process analysis. Flow rate measurement is a typical application of radiotracers. For flow measurements, tracer data are important, rather than the RTD models. Research is going on in refining the existing methods for single phase flow measurement, and in developing new methods for multiphase flow without sampling. The tracer techniques for single phase flow measurements are recognized as ISO standards. This paper presents technical aspect of laboratory experiments, which have been carried out using Molybdenum-99 - Mo99 (radiotracer) to study and determine the flow rate of liquid in multiphase flow rig. The multiphase flow rig consists of 58.7 m long and 20 cm diameter pipeline that can accommodate about 0.296 m 3 of liquid. Tap water was used as liquid flow in pipeline and conventional flow meters were also installed at the flow rig. The flow rate results; radiotracer and conventional flow meter were compared. The total count method was applied for radiotracer technique and showed the comparable results with conventional flow meter. (author)

  19. A built-in radiotracer (24Na) for measuring circulation catalyst rates

    International Nuclear Information System (INIS)

    Domondon, D.B; Berbano, M.C.

    1975-01-01

    A local petroleum refinery intended to calibrate its catalyst flow measuring instrument (propeller blade) using the radioactive tracer technique (RTT). For this purpose, a method of incorporating a suitable radiotracer in commercial catalyst beads had to be found. Two methods of labelling are described. One method involved the incorporation of the radiotracer in a gel of the same composition as the commercial catalyst and subsequent conversion of the gel into a from like that of the commercial catalyst beads. Another method utilized the strong adsorptive properties of the commercial catalyst beads for the chosen isotopes, e.g., 144 Cs, 46 Sc. To effect quantitative adsorption, commercial catalyst beads were simply stirred in a slightly acidic (pH4) chloride solution of the radiotracers for some time. The radiotracers were found to distribute almost uniformly over the entire catalyst surface and no evidence of volatilization of the isotopes from the catalyst surface under condition of use in commercial units was observed. Another probable method was suggested by the Research and Development Division, Philippine Atomic Energy Commission. Aluminium is a major component of the ceramic catalyst beads and sodium is present as impurity. Hence, a radiotracer ( 24 Na) can be formed in the beads by the reaction 23 Na (n,gamma) 24 Na, 27 Al (n,alpha) 24 Na. This possible method of simply irradiating the commercial catalyst beads in the reactor thereby inducing the radiotracer. 24 Na in situ fulfils all the criteria for the selection of an appropriate radiotracer. The method is very simple but reliable

  20. Development and applications of radiotracers technologies and gamma scanning

    International Nuclear Information System (INIS)

    Conejo, Mario; Chaverri, Oscar; Chine, Bruno; Vargas, Celso

    2008-01-01

    The radiotracers and gamma scanning technologies are very consolidated tools for studying, analyzing and evaluating of industrial processes. The development and the results of radiotracers and gamma scanning technologies applied in laboratory and more complex systems, are reported. The radiotracers technology was used to study boron diffusion during the curing process of the wood, to evaluate a lagoon of sewage treatment with aquatic iris plants and to carry out experimental work with controlled variables in a laboratory hydraulic circuit (flow rig). The gamma scanning technique was used to analyze a pilot tower in the laboratories. The main results achieved with the experiments were the following: 1) the boron absorption as a wood curing agent depends on the section of wood exposed to the curing solution; 2) during the tests effectuated with Iodine 131, the aquatic iris plants situated in the water treatment lagoon absorb part of the radiotracer, making difficult the residence time determination; 3) the sensibility of the system Cesium 137 source and detector is sufficiently high and can detect low radioactive absorption materials, situated inside columns with steel walls. (author) [es

  1. Determination of 2D equivalent angles of attack for a non-rotating wind turbine rotor blade

    Energy Technology Data Exchange (ETDEWEB)

    Maassen, W.H.

    1993-11-01

    For the investigation into models to compute the title subject use has been made of the Lanchester-Prandtl lifting line model. The inflow conditions are given by a uniform inflow velocity and the geometrical angles of attack at every spanwise position. A model using pressure measurements at the instrumented sections and a model using 2-dimensional C{sub L}-{alpha} data at certain spanwise positions were investigated. In section two the experimental setups of the experiments at ECN (Netherlands Energy Research Foundation) and FFA (the Aeronautical Research Institute of Sweden) are presented. In section three the theoretical background and the different methods to compute the 2D equivalent angles of attack are outlined. In section four the results of the computations of the downwash and the 2D equivalent angles of attack for the considered FFA wind tunnel experiment is presented. Finally, in section five the most important conclusions are summarized and a recommendation for the computation of the 2D equivalent angles of attack for the non-rotating blade experiments at ECN is formulated. 59 figs., 2 tabs., 3 appendices, 30 refs.

  2. The use of radiotracers in natural rubber research in Malaysia

    International Nuclear Information System (INIS)

    Lai, P.F.; Singh, M.M.

    1981-01-01

    Five main areas where radiotracers have been used in research on natural rubber are on studies on the uptake of plant nutrients by Hevea brasiliensis using 32 P, 86 Rb and 45 Ca as tracers; biosynthesis of Hevea rubber using 14 C or 3 H labelled intermediates; translocation and metabolism of 14 C. Ethephon in Hevea brasiliensis; use of radiotracers as analytical tools and adsorption of labelled fatty acid soaps on natural rubber lattices. These studies are discussed to show the powerful tool that radiotracers provide in agricultural, biochemical and chemical research on natural rubber. (author)

  3. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  4. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    Science.gov (United States)

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  5. Application of radiotracer methods in streamflow measurements

    International Nuclear Information System (INIS)

    Dincer, T.

    1967-01-01

    An attempt is made to evaluate methods using radiotracers in streamflow measurements. The basic principles of the tracer method are explained and background information given. Radiotracers used in stream discharge measurements are discussed and measurements made by different research workers are described. Problems such as adsorption of the tracer and the mixing length are discussed and the potential use of the radioisotopes as tracer in the routine stream-gauging work is evaluated. It is concluded that, at the present stage of development, radiotracer methods do not seem to be ready for routine use in stream-gauging work, and can only be used in some special cases. For gamma-emitting radioisotopes there are problems related to safety, transport and injection which should be solved. Tritium, though a very attractive tracer in some respects, has the disadvantages of having a relatively long half-life and of disturbing the natural tritium levels in the region. Finally, an attempt is made to define the objectives of the research in the field of application of radioisotopes in hydrometry. (author)

  6. Synthesis of new radiotracers based on aniline

    International Nuclear Information System (INIS)

    Ayari, Issra

    2008-01-01

    There are several possible applications of radioactivity, we cite: the study of the functional and neurochirnical aspects related to the brain. This study requires the synthesis of specific radiotracers able to cross their target tissue. The synthesis methods need to be constantly updated to respond to the big demand of this domain. The development of the chemistry of metal complexes helped us to find a stable radiotracer based on aniline and marked with technetium. This stability aI 10wed us to realize a possible biodistribution and to envisage to count the radioactivity and to valid the radiopharmaceutical. (Author)

  7. Synthesis of new radiotracers for tuberculosis diagnosis

    International Nuclear Information System (INIS)

    Keskes, Badis

    2009-01-01

    Tuberculosis remains a worldwide health problem and its diagnosis presents a major challenge. The examinations currently employed are little appreciable and so far there is no reliable diagnosis test. These last years, the development of the new radiopharmaceuticals, referred to diagnosis, has revived interest in the search for new molecules with a tropism to a particular disease. Thanks to this field, which lies at the interface of organic and organometallic chemistry, nuclear medicine and biology, we have been led to synthesize a technetium radiotracer linked to isoniazid. For the identification of this radiotracer, we used its similar rhenium model. (Author)

  8. Synthesis of new radiotracers based of Ethyl Ester

    International Nuclear Information System (INIS)

    Trabelsi, Donia

    2008-01-01

    The in vivo study of a biochemical or physiological process requires the synthesis of specific radiotracers but also the targeting of these compounds so that they can reach their target tissue. Methodologies original synthesis associated with radioisotopes used, the quantities and chemical forms often have to be available developed. The chemistry of metal complexes booming, we were able to use the ethyl ester combined with technetium, forming a stable radiotracer. Finally, a counting of radioactivity in different rat's organs completed our study. (Author)

  9. Radiotracer techniques in hydrological studies

    International Nuclear Information System (INIS)

    Oladipo, M.O.A.; Funtua, I.I.

    2000-07-01

    The use of radioactive tracers particularly short-lived radioisotopes frequently offers advantages over conventional methods of analyses. Applications of nuclear techniques in the field of hydrology constitute important and sometimes unique tools for obtaining critical information needed for water resources management. Essentially, radiotracer techniques offer a safe, cost effective and powerful tool in the assessment, management and protection of water resources. The Centre for Energy Research and Training, Ahmadu Bello University, Zaria of late has been offering consultancy services to some industries in the area of radiotracer technique. The first nuclear reactor in Nigeria, the MNSR, is expected to be commissioned in the Centre very soon. Many short-lived radioisotopes such as Cu-64, Ga-72, Br-82, Hg-197 etc which are very important in hydrological studies can be produced by the MNSR facility. This article reports on the basic principles of the technique and its roles in hydrology

  10. Radiotracer studies for coastal zone management

    International Nuclear Information System (INIS)

    Hughes, C.; Kluss, T.; Airey, P.

    2001-01-01

    Coastal engineers and coastal zone managers increasingly rely on numerical models of fluid, sediment and contaminant dynamics. These are used to underpin coastal structure design and to predict environmental response to specific events such as storms or pollutant spills, and gradual changes such as sea-level rise or changes in bathymetry. Radiotracer techniques can be used to provide dynamic data on the movement of a specific patch of water, sediment or pollutant over time, which can be compared with model predictions. Two case studies are presented where radiotracer studies were used to improve confidence in numerical models of: (1) 2D hydrodynamics and sediment transport at the Port of Songkhla, Thailand; and (2) 3D hydrodynamics and algal bloom transport in Manila Bay, Philippines

  11. A computational procedure to define the incidence angle on airfoils rotating around an axis orthogonal to flow direction

    International Nuclear Information System (INIS)

    Bianchini, Alessandro; Balduzzi, Francesco; Ferrara, Giovanni; Ferrari, Lorenzo

    2016-01-01

    Highlights: • New method to calculate the incidence angle from a computed CFD flow field. • Applicable to each airfoil rotating around an axis orthogonal to flow direction. • Composed by four, easily automatable steps explained in details. • Robustness of the model assessed on two Darrieus turbine study cases. - Abstract: Numerical simulations provided in the last few years a significant contribution for a better understanding of many phenomena connected to the flow past rotating blades. In case of airfoils rotating around an axis orthogonal to flow direction, one of the most critical issues is represented by the definition of the incidence angle on the airfoil from the computed flow field. Incidence indeed changes continuously as a function of the azimuthal position of the blade and a distribution of peripheral speed is experienced along the airfoil’s thickness due to radius variation. The possibility of reducing the flow to lumped parameters (relative speed modulus and direction), however, would be of capital relevance to transpose accurate CFD numerical results into effective inputs to low-order models that are often exploited for preliminary design analyses. If several techniques are available for this scope in the case of blades rotating around an axis parallel to flow direction (e.g., horizontal-axis wind turbines), the definition of a robust procedure in case the revolution axis is orthogonal to the flow is still missing. In the study, a novel technique has been developed using data from Darrieus-like rotating airfoils. The method makes use of the virtual camber theory to define a virtual airfoil whose pressure coefficient distributions in straight flow are used to match those of the real airfoil in curved flow. Even if developed originally for vertical-axis wind turbines, the method is of general validity and is thought to represent in the near future a valuable tool for researchers to get a new insight on many complex phenomena connected to flow

  12. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.; Sabry, Hanan M.; Gadelhak, Mahmoud I.

    2012-01-01

    usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space

  13. CFD simulation of homogenisation time measured by radiotracers

    International Nuclear Information System (INIS)

    Thyn, J.; Novy, M.; Zitny, R.; Mostik, M.; Jahoda, M.

    2004-01-01

    A methodology for CFD (Computational Fluid Dynamics) simulation of radiotracer experiments was suggested. The most important parts of the methodology for validation of CFD results by radiotracers are: a) successful simulation of tracer experiment by CFD code (numerical solution of tracer dispersion in a stirred tank), which results in tracer concentration field at several time intervals; b) post-process data treatment, which uses detection chain description and which enables to simulate the detector measurement of homogenisation time from the tracer concentration field evaluated by CFD code. (author)

  14. Production of 41Ar and 79Kr gaseous radiotracers for industrial applications

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Jagadeesan, K.C.; Shivarudrappa, V.; Sharma, V.K.; Chitra, S.

    2007-01-01

    Radiotracers are extensively used in many industries for trouble shooting and optimization of process parameters leading to considerable savings in time and huge economic benefits. In chemical and petrochemical industries different gases and vapours flowing in the conversion reactors play a major role in the final production. Gaseous radiotracers are ideal to study hydrodynamics of gas phases in process vessels. 41 Ar and 79 Kr are the preferred gaseous radiotracers for such studies. Owing to the increase in demand from Indian industries for gas phase radiotracers, efforts have been made to produce 41 Ar and 79 Kr indigenously by irradiation of 40 Ar and enriched 78 Kr gaseous targets in research reactors. Prequalification of the containers used, safety aspects concerning accidental rupture and mandatory tests necessary for irradiation of gaseous targets in the reactors have been studied. The paper describes some of the important safety aspects involved and the results of trial irradiations on the production of 41 Ar and 79 Kr radiotracers. Standardization of suitable assay protocols for their regular production and supply for applications in industries is also described. (author)

  15. Reliability of the Phi angle to assess rotational alignment of the talar component in total ankle replacement.

    Science.gov (United States)

    Manzi, Luigi; Villafañe, Jorge Hugo; Indino, Cristian; Tamini, Jacopo; Berjano, Pedro; Usuelli, Federico Giuseppe

    2017-11-08

    The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component. Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated. Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; pPhi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05). Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane. Level II, cross sectional study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  16. Use of radiotracers for studies of metal sorption behaviour

    International Nuclear Information System (INIS)

    McCubbin, D.; Leonard, K.S.

    1995-01-01

    Radiotracers provide a convenient tool to study the behaviour of metal ions and other contaminants in natural waters. Furthermore, the use of radiotracers in controlled laboratory experiments provides an ideal approach for investigating, in a systematic manner, the role of individual parameters on processes, at mass concentrations found in the environment. A simplistic procedure has been developed to produce a thorium radiotracer ( 234 Th), in a similar chemical form (non-acidic) to that of the aquatic medium under investigation, to determine the kinetics of sorption to marine particulate material. The benefit of this procedure is that the system is likely to be perturbed to a lesser extent by changes in pH and dissolved Th species following tracer addition. Results from filtering different tracer batches through membranes, to determine the sorption characteristics prior to use, indicate that the physico-chemical behaviour of individual batches was extremely variable. Not surprisingly, the amount of uptake immediately following tracer additions to solutions containing marine particulate material was also variable. It is suggested that the role of tracer may be underestimated if added in acid form. Nevertheless, having accounted for the initial sorption, the subsequent uptake between different batches was reasonably reproducible. The usefulness of radiotracers is discussed in the context of these observations

  17. Radiotracer technique for leakage detection under simulated conditions

    International Nuclear Information System (INIS)

    Yelgaonkar, V.N.; Sharma, V.K.; Tapase, A.S.

    2001-01-01

    Radiotracer techniques are often used to locate leaks in underground pipelines. An attempt was made to standardize radiotracer pulse migration in terms of minimum detectable limit. For this purpose a 6 inch diameter 1200 long steel pipe was used. Two leak rates viz. 10 litres per minute and 1 litre per minute with an accuracy of ± 10% were simulated. The experiments on this pipeline showed that this method could be used to locate a leak of the order of 1 litre per minute in a 6 inch diameter isolated underground pipeline. (author)

  18. Determination of the structural phase and octahedral rotation angle in halide perovskites

    Science.gov (United States)

    dos Reis, Roberto; Yang, Hao; Ophus, Colin; Ercius, Peter; Bizarri, Gregory; Perrodin, Didier; Shalapska, Tetiana; Bourret, Edith; Ciston, Jim; Dahmen, Ulrich

    2018-02-01

    A key to the unique combination of electronic and optical properties in halide perovskite materials lies in their rich structural complexity. However, their radiation sensitive nature limits nanoscale structural characterization requiring dose efficient microscopic techniques in order to determine their structures precisely. In this work, we determine the space-group and directly image the Br halide sites of CsPbBr3, a promising material for optoelectronic applications. Based on the symmetry of high-order Laue zone reflections of convergent-beam electron diffraction, we identify the tetragonal (I4/mcm) structural phase of CsPbBr3 at cryogenic temperature. Electron ptychography provides a highly sensitive phase contrast measurement of the halide positions under low electron-dose conditions, enabling imaging of the elongated Br sites originating from the out-of-phase octahedral rotation viewed along the [001] direction of I4/mcm persisting at room temperature. The measurement of these features and comparison with simulations yield an octahedral rotation angle of 6.5°(±1.5°). The approach demonstrated here opens up opportunities for understanding the atomic scale structural phenomena applying advanced characterization tools on a wide range of radiation sensitive halide-based all-inorganic and hybrid organic-inorganic perovskites.

  19. Current status and trends of cooperation on radiotracer and NCS technologies

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency, Vienna (Austria). Industrial Applications and Chemistry Section

    1997-10-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on `Radiotracer technology for engineering unit operations studies and unit process optimisation` aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on `Multibeam radiogauging for multi-phase systems studies` to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  20. Current status and trends of cooperation on radiotracer and NCS technologies

    International Nuclear Information System (INIS)

    Thereska, J.

    1997-01-01

    Relevant target areas for radiotracer and neutronic control system (NCS) applications are defined. The petroleum and petrochemical industries, mineral processing and waste-water treatment sectors are identified as the most appropriate beneficiaries. The new CRP on 'Radiotracer technology for engineering unit operations studies and unit process optimisation' aims to improve the radiotracer methodology, including new radiotracers, development of expert systems, new software for data processing with finite element techniques for flow structure visualisation, as well as to formulate guidelines for problem solving of complex processes. The organisation of a CRP on 'Multibeam radiogauging for multi-phase systems studies' to further develop and refine nucleonic gauge methodology and technology, including development of expert systems for optimal design and calibration, quality control according to ISO standards, emerging new applications, and formulation of guidelines and software for on line measurement of multi-phase system parameters of complex processes will be discussed in the near future

  1. Simultaneous Detection of Displacement, Rotation Angle, and Contact Pressure Using Sandpaper Molded Elastomer Based Triple Electrode Sensor.

    Science.gov (United States)

    Choi, Eunsuk; Sul, Onejae; Lee, Seung-Beck

    2017-09-06

    In this article, we report on a flexible sensor based on a sandpaper molded elastomer that simultaneously detects planar displacement, rotation angle, and vertical contact pressure. When displacement, rotation, and contact pressure are applied, the contact area between the translating top elastomer electrode and the stationary three bottom electrodes change characteristically depending on the movement, making it possible to distinguish between them. The sandpaper molded undulating surface of the elastomer reduces friction at the contact allowing the sensor not to affect the movement during measurement. The sensor showed a 0.25 mm −1 displacement sensitivity with a ±33 μm accuracy, a 0.027 degree −1 of rotation sensitivity with ~0.95 degree accuracy, and a 4.96 kP −1 of pressure sensitivity. For possible application to joint movement detection, we demonstrated that our sensor effectively detected the up-and-down motion of a human forefinger and the bending and straightening motion of a human arm.

  2. Photoelectron spectra of N2+: Rotational line profiles studied with HeI-excited angle-resolved spectroscopy and with synchrotron radiation

    International Nuclear Information System (INIS)

    Ohrwall, G.; Baltzer, P.; Bozek, J.

    2004-01-01

    We have recorded angle-resolved He I photoelectron spectra of the three outer most valence states in N+2, with high enough resolution to observe rotational line profiles. For the two Sigma states, the X 2 Sigma +g and the B 2 Sigma +u, we found that the rotational branches corresponding to different changes in rotational quantum number can differ dramatically in beta value. The well-known difference in beta value for the nu=0 and nu =1 vibrations of the X 2 Sigma +g state was found to be due to different rotational branching ratios and also different beta values of the rotational branches. For the nu=0-2 vibrations of the A 2 Pi u state, the beta value difference between rotational branches is much less pronounced than in the X and B states. We have also recorded synchrotron-radiation-excited photoelectron spectra of the nu=0 vibrational peaks of the X 2 Sigma +g and B 2 Sigma +u states where rotational line profiles are resolved. The intensities of the rotational branches were studied as function of photon energy, the X state between 23 and 65 eV, and We have recorded angle-resolved He I photoelectron spectra of the three outermost valence states in N+2, with high enough resolution to observe rotational line profiles. For the two Sigma states, the X 2 Sigma +g and the B 2 Sigma +u, we found that the rotational branches corresponding to different changes in rotational quantum number can differ dramatically in beta value. The well-known difference in beta value for the nu=0 and nu=1 vibrations of the X 2 Sigma +g state was found to be due to different rotational branching ratios and also different beta values of the rotational branches. For the nu=0-2 vibrations of the A 2 Pi u state, the beta value difference between rotational branches is much less pronounced than in the X and B states. We have also recorded synchrotron-radiation-excited photoelectron spectra of the nu=0 vibrational peaks of the X 2 Sigma +g and B 2 Sigma +u states where rotational line profiles a

  3. Radiotracer investigations in oil production and water injection wells

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1977-01-01

    Injection of gamma emitting radiotracers into oil wells followed by logging provides information on several aspects such as the identification of zones of seepage of water in the water injection wells and also the location of source of water entering oil producting wells. The experience gained in the application of bromine-82 and rubidium-86 as radiotracers in such studies at the Ankleshwar and Kalol oil fields in Gujarat and Nazira in Assam has been briefly reported. (author)

  4. Preliminary study of the use of radiotracers for leak detection in industrial applications

    International Nuclear Information System (INIS)

    Wetchagarun, S; Petchrak, A; Tippayakul, C

    2015-01-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH 4 Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system. (paper)

  5. Preliminary study of the use of radiotracers for leak detection in industrial applications

    Science.gov (United States)

    Wetchagarun, S.; Petchrak, A.; Tippayakul, C.

    2015-05-01

    One of the most widespread uses of radiotracers in the industrial applications is the leak detection of the systems. This technique can be applied, for example, to detect leak in heat exchangers or along buried industrial pipelines. The ability to perform online investigation is one of the most important advantages of the radiotracer technique over other non-radioactive leak detection methods. In this paper, a preliminary study of the leak detection using radiotracer in the laboratory scale was presented. Br-82 was selected for this work due to its chemical property, its suitable half-life and its on-site availability. The NH4Br in the form of aqueous solution was injected into the experimental system as the radiotracer. Three NaI detectors were placed along the pipelines to measure system flow rate and to detect the leakage from the piping system. The results obtained from the radiotracer technique were compared to those measured by other methods. It is found that the flow rate obtained from the radiotracer technique agreed well with the one obtained from the flow meter. The leak rate result, however, showed discrepancy between results obtained from two different measuring methods indicating further study on leak detection was required before applying this technique in the industrial system.

  6. Sex differences in mental rotation and line angle judgments are positively associated with gender equality and economic development across 53 nations.

    Science.gov (United States)

    Lippa, Richard A; Collaer, Marcia L; Peters, Michael

    2010-08-01

    Mental rotation and line angle judgment performance were assessed in more than 90,000 women and 111,000 men from 53 nations. In all nations, men's mean performance exceeded women's on these two visuospatial tasks. Gender equality (as assessed by United Nations indices) and economic development (as assessed by per capita income and life expectancy) were significantly associated, across nations, with larger sex differences, contrary to the predictions of social role theory. For both men and women, across nations, gender equality and economic development were significantly associated with better performance on the two visuospatial tasks. However, these associations were stronger for the mental rotation task than for the line angle judgment task, and they were stronger for men than for women. Results were discussed in terms of evolutionary, social role, and stereotype threat theories of sex differences.

  7. History and present status of field application of radiotracers, (2)

    International Nuclear Information System (INIS)

    Koyama, Takeo; Shimizu, Makoto.

    1988-01-01

    In the field of agriculture, radiotracers were first used in 1957 in studies for improvement in fertilizing techniques. Techniques were established for accurate measurement of extremely low radioactivity in crops and for the separate determination of the phosphorus in crops of the fertilizer origin and soil origin. Then, RI or stable isotope tracing test methods were developed using 32 P or 15 N to determine the flow and absorption of fertilizers. Other techniques using radiotracers developed in this period served for the construction of maps of the root activity of crops, investigation of the effects of different fertilizers in farms where double-cropping was practised, identification of suitable fertilizers for orange cultivation, development of new fertilizing techniques for Japanese persimmon cultivation, etc. Practically, no field use of radiotracers has been found since 1970. At present, it is prohibited and replaced by other techniques using stable isotopes, etc. In the field fishery, radiotracers have been used for studies of various dynamic phenomena including the flow of water and deposits in the sea, behaviors of fish, food, chain, circulation of chemical substances in the ecological system, etc. (Nogami, K.)

  8. Bundle Block Adjustment of Airborne Three-Line Array Imagery Based on Rotation Angles

    Directory of Open Access Journals (Sweden)

    Yongjun Zhang

    2014-05-01

    Full Text Available In the midst of the rapid developments in electronic instruments and remote sensing technologies, airborne three-line array sensors and their applications are being widely promoted and plentiful research related to data processing and high precision geo-referencing technologies is under way. The exterior orientation parameters (EOPs, which are measured by the integrated positioning and orientation system (POS of airborne three-line sensors, however, have inevitable systematic errors, so the level of precision of direct geo-referencing is not sufficiently accurate for surveying and mapping applications. Consequently, a few ground control points are necessary to refine the exterior orientation parameters, and this paper will discuss bundle block adjustment models based on the systematic error compensation and the orientation image, considering the principle of an image sensor and the characteristics of the integrated POS. Unlike the models available in the literature, which mainly use a quaternion to represent the rotation matrix of exterior orientation, three rotation angles are directly used in order to effectively model and eliminate the systematic errors of the POS observations. Very good experimental results have been achieved with several real datasets that verify the correctness and effectiveness of the proposed adjustment models.

  9. Application of radiotracers in environmental studies

    International Nuclear Information System (INIS)

    Rathore, V.S.

    1994-01-01

    An attempt has been made to present recently emerging trends in the applicability of radiotracers in environmental studies. Since the topic is of general interest and still in the infancy, basic aspects of sampling, instrumentation and methodology are also covered

  10. Critical shoulder angle in an East Asian population: correlation to the incidence of rotator cuff tear and glenohumeral osteoarthritis.

    Science.gov (United States)

    Shinagawa, Kiyotsugu; Hatta, Taku; Yamamoto, Nobuyuki; Kawakami, Jun; Shiota, Yuki; Mineta, Mitsuyoshi; Itoi, Eiji

    2018-05-03

    Focus has recently been on the critical shoulder angle (CSA) as a factor related to rotator cuff tear and osteoarthritis (OA) in the European population. However, whether this relationship is observed in the Asian population is unclear. The correlation between the CSAs measured on anteroposterior radiographs and the presence or absence of rotator cuff tears or OA changes was assessed in 295 patients. Rotator cuff tears were diagnosed with magnetic resonance imaging or ultrasonography. OA findings were classified using the Samilson-Prieto classification. The CSAs among the patients with rotator cuff tears, OA changes, and those without pathologies were compared. Multivariable analyses were used to clarify the potential risks for these pathologies. The mean CSA with rotator cuff tear (33.9° ± 4.1°) was significantly greater than that without a rotator cuff tear (32.3° ± 4.5°; P = .002). Multivariable analysis also showed that a greater CSA had a significantly increased risk of rotator cuff tears, with the odds ratio of 1.08 per degree. OA findings showed no significant correlation to the CSAs. Our study demonstrates that the CSA is greater in those with a rotator cuff tear than in those without a tear or OA changes, which may be an independent risk factor for the incidence of rotator cuff tears in the Japanese population. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. CENTRAL ROTATIONS OF MILKY WAY GLOBULAR CLUSTERS

    International Nuclear Information System (INIS)

    Fabricius, Maximilian H.; Rukdee, Surangkhana; Saglia, Roberto P.; Bender, Ralf; Hopp, Ulrich; Thomas, Jens; Williams, Michael J.; Noyola, Eva; Opitsch, Michael

    2014-01-01

    Most Milky Way globular clusters (GCs) exhibit measurable flattening, even if on a very low level. Both cluster rotation and tidal fields are thought to cause this flattening. Nevertheless, rotation has only been confirmed in a handful of GCs, based mostly on individual radial velocities at large radii. We are conducting a survey of the central kinematics of Galactic GCs using the new Integral Field Unit instrument VIRUS-W. We detect rotation in all 11 GCs that we have observed so far, rendering it likely that a large majority of the Milky Way GCs rotate. We use published catalogs of GCs to derive central ellipticities and position angles. We show that in all cases where the central ellipticity permits an accurate measurement of the position angle, those angles are in excellent agreement with the kinematic position angles that we derive from the VIRUS-W velocity fields. We find an unexpected tight correlation between central rotation and outer ellipticity, indicating that rotation drives flattening for the objects in our sample. We also find a tight correlation between central rotation and published values for the central velocity dispersion, most likely due to rotation impacting the old dispersion measurements

  12. Estimation of tritium radiotracer activity for interconnection study in geothermal field

    International Nuclear Information System (INIS)

    Rasi Prasetio; Satrio

    2016-01-01

    Tritium radiotracer (3H) has been applied widely in many geothermal fields around the world. This application was done by injecting radiotracer with certain amount of activity into reinjection well in order to investigate interconnection between reinjection well with surrounding production wells. The activity of injected radiotracer must meets the field condition and the volume of reservoir, detection limit of instrument, as well as safety aspect for the workers and environment from radioactive hazard. The planning of injection process must consider the maximum permissible concentration (MPC) and minimum detection limit (MDL). Based on calculation, tritium radiotracer injection in Kamojang geothermal field can be done with minimal activity of 0.15 Ci and maximum 22100 Ci, while in Lahendong field minimum activity of 0.65 Ci and maximum 7230 Ci. In these two injection studies, tritium was detected in monitoring wells between MDL and MPC limit. By using this estimation calculation, the activity of tritium that released into the environment within safety limit, thus monitoring wells with undetectable tritium infer no connectivity between those wells with reinjection well. (author)

  13. Variable angle asymmetric cut monochromator

    International Nuclear Information System (INIS)

    Smither, R.K.; Fernandez, P.B.

    1993-09-01

    A variable incident angle, asymmetric cut, double crystal monochromator was tested for use on beamlines at the Advanced Photon Source (APS). For both undulator and wiggler beams the monochromator can expand area of footprint of beam on surface of the crystals to 50 times the area of incident beam; this will reduce the slope errors by a factor of 2500. The asymmetric cut allows one to increase the acceptance angle for incident radiation and obtain a better match to the opening angle of the incident beam. This can increase intensity of the diffracted beam by a factor of 2 to 5 and can make the beam more monochromatic, as well. The monochromator consists of two matched, asymmetric cut (18 degrees), silicon crystals mounted so that they can be rotated about three independent axes. Rotation around the first axis controls the Bragg angle. The second rotation axis is perpendicular to the diffraction planes and controls the increase of the area of the footprint of the beam on the crystal surface. Rotation around the third axis controls the angle between the surface of the crystal and the wider, horizontal axis for the beam and can make the footprint a rectangle with a minimum. length for this area. The asymmetric cut is 18 degrees for the matched pair of crystals, which allows one to expand the footprint area by a factor of 50 for Bragg angles up to 19.15 degrees (6 keV for Si[111] planes). This monochromator, with proper cooling, will be useful for analyzing the high intensity x-ray beams produced by both undulators and wigglers at the APS

  14. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    International Nuclear Information System (INIS)

    Wiebe, L.I.

    1984-01-01

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use. (author)

  15. Radionuclides, radiotracers and radiopharmaceuticals for in vivo diagnosis

    Science.gov (United States)

    Wiebe, Leonard I.

    Radioactive tracers for in vivo clinical diagnosis fall within a narrow, strictly-defined set of specifications in respect of their physical properties, chemical and biochemical characteristics, and (approved) medical applications. The type of radioactive decay and physical half-life of the radionuclide are immutable properties which, along with the demands of production and supply, limit the choice of radionuclides used in medicine to only a small fraction of those known to exist. In use, the biochemical and physiological properties of a radiotracer are dictated by the chemical form of the radionuclide. This chemical form may range from elemental, molecular or ionic, to complex compounds formed by coordinate or covalent bonding of the radionuclide to either simple organic or inorganic molecules, or complex macromolecules. Few of the radiotracers which are tested in model systems ever become radiopharmaceuticals in the strictest sense. Radionuclides, radiotracers and radiopharmaceuticals in use are reviewed. Drug legislation and regulations concerning drug manufacture, as well as hospital ethical constraints and legislation concerning unsealed sources of radiation must all be satisfied in order to translate a radiopharmaceutical from the laboratory to clinical use.

  16. VMAT optimization with dynamic collimator rotation.

    Science.gov (United States)

    Lyu, Qihui; O'Connor, Daniel; Ruan, Dan; Yu, Victoria; Nguyen, Dan; Sheng, Ke

    2018-04-16

    Although collimator rotation is an optimization variable that can be exploited for dosimetric advantages, existing Volumetric Modulated Arc Therapy (VMAT) optimization uses a fixed collimator angle in each arc and only rotates the collimator between arcs. In this study, we develop a novel integrated optimization method for VMAT, accounting for dynamic collimator angles during the arc motion. Direct Aperture Optimization (DAO) for Dynamic Collimator in VMAT (DC-VMAT) was achieved by adding to the existing dose fidelity objective an anisotropic total variation term for regulating the fluence smoothness, a binary variable for forming simple apertures, and a group sparsity term for controlling collimator rotation. The optimal collimator angle for each beam angle was selected using the Dijkstra's algorithm, where the node costs depend on the estimated fluence map at the current iteration and the edge costs account for the mechanical constraints of multi-leaf collimator (MLC). An alternating optimization strategy was implemented to solve the DAO and collimator angle selection (CAS). Feasibility of DC-VMAT using one full-arc with dynamic collimator rotation was tested on a phantom with two small spherical targets, a brain, a lung and a prostate cancer patient. The plan was compared against a static collimator VMAT (SC-VMAT) plan using three full arcs with 60 degrees of collimator angle separation in patient studies. With the same target coverage, DC-VMAT achieved 20.3% reduction of R50 in the phantom study, and reduced the average max and mean OAR dose by 4.49% and 2.53% of the prescription dose in patient studies, as compared with SC-VMAT. The collimator rotation co-ordinated with the gantry rotation in DC-VMAT plans for deliverability. There were 13 beam angles in the single-arc DC-VMAT plan in patient studies that requires slower gantry rotation to accommodate multiple collimator angles. The novel DC-VMAT approach utilizes the dynamic collimator rotation during arc

  17. Panel discussion: Chemistry aspects of pet radiotracers

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    A panel discussion on the radiotracer development process opened with a question regarding the role of toxicological studies in the process of obtaining a physician-sponsored Investigational New Drug (IND) for a new radiopharmaceutical. Panel members were uniformly supportive of new radiotracer development, expressing their opinions that the regulatory hurdles were there but could be overcome. Several institutions are actively working with regulatory agencies to determine just what toxicology data are relevant to new radiopharmaceutical development in the PET field. The FDA is beginning to understand that the pharmacology of PET tracer doses may be completely different from what is usually important in drug trials. The second part of the panel discussion centered on the role, if any, of the pharmaceutical companies in new radiotracer development. It was pointed out that what the radiochemist is looking for in a radiopharmaceutical is different from what these companies are searching for in a therapeutic drug. Panel and audience members responded to the question: What would a pharmaceutical company gain from collaboration with radiopharmaceutical research laboratories? Several examples were given such as providing crucial data from humans rather than animals; determining individualized drug doses to maximize the therapeutic index of a new drug regimen; and replacing the large amounts of time and money currently invested by drug companies in the radiolabeling and evaluation of metabolites of new drugs

  18. INFORMATIONAL MODEL OF MENTAL ROTATION OF FIGURES

    Directory of Open Access Journals (Sweden)

    V. A. Lyakhovetskiy

    2016-01-01

    Full Text Available Subject of Study.The subject of research is the information structure of objects internal representations and operations over them, used by man to solve the problem of mental rotation of figures. To analyze this informational structure we considered not only classical dependencies of the correct answers on the angle of rotation, but also the other dependencies obtained recently in cognitive psychology. Method.The language of technical computing Matlab R2010b was used for developing information model of the mental rotation of figures. Such model parameters as the number of bits in the internal representation, an error probability in a single bit, discrete rotation angle, comparison threshold, and the degree of difference during rotation can be changed. Main Results.The model reproduces qualitatively such psychological dependencies as the linear increase of time of correct answers and the number of errors on the angle of rotation for identical figures, "flat" dependence of the time of correct answers and the number of errors on the angle of rotation for mirror-like figures. The simulation results suggest that mental rotation is an iterative process of finding a match between the two figures, each step of which can lead to a significant distortion of the internal representation of the stored objects. Matching is carried out within the internal representations that have no high invariance to rotation angle. Practical Significance.The results may be useful for understanding the role of learning (including the learning with a teacher in the development of effective information representation and operations on them in artificial intelligence systems.

  19. Radiotracer study of phosphate exchange between whey and casein micelles in cow's milk

    International Nuclear Information System (INIS)

    Kolar, Z.I.; Verburg, T.G.; Dijk, H.J.M. van

    1998-01-01

    Radiotracer method has been applied to study exchange of calcium ions between the whey calcium salts and micellar calcium phosphate (MCP). The present paper deals with a similar study pertaining to phosphate ions. 32 P-labelled Na 2 HPO 4 was used as the radiotracer for inorganic phosphates of milk. After addition of the radiotracer to skimmed-milk, samples were taken regularly for 700 hours. In the samples casein micelles were separated from whey by ultracentrifugation and finally the radiotracer quantity i.e. 32 P-concentration in the whey samples was measured using a Liquid Scintillation Counter. Compartmental analysis and modelling were used to evaluate the thus obtained time curves for radiotracer quantity in whey. This analysis revealed the presence of three phosphate compartments i.e. exchangeable phosphate entities; one being the whey phosphate. The other two are associated with the exchangeable phosphates of MCP. The mean residence times of phosphate in the latter two compartment differ considerably pointing at two distinctly different embeddings of phosphate groups in the structure of the micellar calcium phosphate of the cow's milk casein. The obtained results are in fair agreement with the mentioned model of MCP

  20. Central Rotations of Milky Way Globular Clusters

    Science.gov (United States)

    Fabricius, Maximilian H.; Noyola, Eva; Rukdee, Surangkhana; Saglia, Roberto P.; Bender, Ralf; Hopp, Ulrich; Thomas, Jens; Opitsch, Michael; Williams, Michael J.

    2014-06-01

    Most Milky Way globular clusters (GCs) exhibit measurable flattening, even if on a very low level. Both cluster rotation and tidal fields are thought to cause this flattening. Nevertheless, rotation has only been confirmed in a handful of GCs, based mostly on individual radial velocities at large radii. We are conducting a survey of the central kinematics of Galactic GCs using the new Integral Field Unit instrument VIRUS-W. We detect rotation in all 11 GCs that we have observed so far, rendering it likely that a large majority of the Milky Way GCs rotate. We use published catalogs of GCs to derive central ellipticities and position angles. We show that in all cases where the central ellipticity permits an accurate measurement of the position angle, those angles are in excellent agreement with the kinematic position angles that we derive from the VIRUS-W velocity fields. We find an unexpected tight correlation between central rotation and outer ellipticity, indicating that rotation drives flattening for the objects in our sample. We also find a tight correlation between central rotation and published values for the central velocity dispersion, most likely due to rotation impacting the old dispersion measurements. This Letter includes data taken at The McDonald Observatory of The University of Texas at Austin.

  1. Status and perspective on radiotracer technology and development of its equipment in Korea

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee; Jin, Joon Ha

    2003-01-01

    The Korean tracer team was organized under the regular research project in the middle of 1990s. The objective of the project is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems. The Korean tracer team started with basic tracer technologies and basic tools for radiotracer experiment. Under the research project, various equipments and skills for radiotracer have been developed. With these skill and equipment, there have been several demonstration experiments in petrochemical industry and waste water treatment facilities. The direction of research using radiotracer technology is highly reflected by each country's industrial situation. There is overview on how the tracer technology has applied to the industries in Korea in this paper. And the case on the application of radiotracer technology and the development of its equipment in Korea are also introduced in this paper

  2. Relationship of frontal plane rotation of first metatarsal to proximal articular set angle and hallux alignment in patients undergoing tarsometatarsal arthrodesis for hallux abducto valgus: a case series and critical review of the literature.

    Science.gov (United States)

    Dayton, Paul; Feilmeier, Mindi; Kauwe, Merrell; Hirschi, Jordan

    2013-01-01

    Rotation of the first metatarsal, as a component of hallux abducto valgus, is rarely discussed and is not addressed as a component of most hallux valgus corrective procedures. We believe frontal plane rotation of the first metatarsal to be an integral component of hallux abducto valgus deformity (the "third plane of deformity") and believe de-rotation is necessary for complete deformity correction. We observed the change in angular measurements commonly used in the evaluation of hallux valgus deformity in patients who underwent a modified lapidus procedure. We measured the intermetatarsal angle, hallux abductus angle, proximal articular set angle, and tibial sesamoid position on weightbearing radiographs of 25 feet in 24 patients who had undergone tarsal metatarsal corrective arthrodesis and lateral capsular release. Specific attention was given to reduction of the frontal plane rotation of the first metatarsal during correction. Our results showed a change in the angular measurements observed by 4 investigators as follows. The mean change in the intermetatarsal angle was 10.1° (p hallux abductus angle was 17.8° (p valgus, or everted position of the first metatarsal, was noted as a component of the hallux abducto valgus deformity in our patient population and was corrected by varus rotation or inversion of the metatarsal. We also reviewed the current literature related to anatomic changes in the first ray in the patient with hallux valgus deformity and reviewed our hypothesis regarding the reduction in the proximal articular set angle, which we believe to be related to frontal plane rotation of the first metatarsal, resulting in a radiographic artifact. Copyright © 2013. Published by Elsevier Inc.

  3. New-generation radiotracers for nAChR and NET

    Energy Technology Data Exchange (ETDEWEB)

    Ding Yushin [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)]. E-mail: ding@bnl.gov; Fowler, Joanna [Chemistry Department, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2005-10-01

    Advances in radiotracer chemistry and instrumentation have merged to make positron emission tomography (PET) a powerful tool in the biomedical sciences. Positron emission tomography has found increased application in the study of drugs affecting the brain and whole body, including the measurement of drug pharmacokinetics (using a positron-emitter-labeled drug) and drug pharmacodynamics (using a labeled tracer). Thus, radiotracers are major scientific tools enabling investigations of molecular phenomena, which are at the heart of understanding human disease and developing effective treatments; however, there is evidently a bottleneck in translating basic research to clinical practice. In the meantime, the poor ability to predict the in vivo behavior of chemical compounds based on their log P's and affinities emphasizes the need for more knowledge in this area. In this article, we focus on the development and translation of radiotracers for PET studies of the nicotinic acetylcholine receptor (nAChR) and the norepinephrine transporter (NET), two molecular systems that urgently need such an important tool to better understand their functional significance in the living human brain.

  4. Regulatory requirements for fluorine 18-labelled radiotracers

    International Nuclear Information System (INIS)

    Prigent, A.

    2005-01-01

    Although European and French regulations define radiopharmaceuticals and their different conditions for use, there is no legal status of the radiotracer. Radiotracer is commonly known as a molecular entity administered in tracer doses, that means at very low masses (e.g., nano-mol amounts) and, consequently, without any pharmacological effect. A radiotracer can meet the specifications of either a radiochemical (usually restricted to research in animal models) or a radiopharmaceutical (human use for diagnostic imaging or research projects). Besides the 'proprietary medicinal product', different status have been defined to allow other uses in humans, referring to 'magistral formula' preparation, 'officinal formula' preparation, investigational medicinal product for clinical trials, or to a radiopharmaceutical with a 'patient named authorization'. However, because of the short half-life of fluorine 18 and expanding development of molecular imaging techniques using positron emission tomography (PET), the current regulation is sometimes considered as inappropriate with regard to the small-size production required for such on-site manufactured radiopharmaceuticals. It is often claimed that it could be very difficult to comply with the current Good Manufactured Practice (cGMP). As previously done for radiopharmaceuticals based on monoclonal antibodies, specific adjustments for PET radiopharmaceuticals are under discussion and the 'note for guidance on radiopharmaceuticals' will be soon revised by the Committee for Medicinal Products for Human Use (CHMP) of the European Medicines Agency (EMEA). In many cases, a status of 'magistral' product might be attributed to a PET radiopharmaceutical manufactured according with European Pharmacopoeia monographs. (author)

  5. Adsorption on smooth electrodes: A radiotracer study

    International Nuclear Information System (INIS)

    Rice-Jackson, L.M.

    1990-01-01

    Adsorption on solids is a complicated process and in most cases, occurs as the early stage of other more complicated processes, i.e. chemical reactions, electrooxidation, electroreduction. The research reported here combines the electroanalytical method, cyclic voltammetry, and the use of radio-labeled isotopes, soft beta emitters, to study adsorption processes at smooth electrodes. The in-situ radiotracer method is highly anion (molecule) specific and provides information on the structure and composition of the electric double layer. The emphasis of this research was on studying adsorption processes at smooth electrodes of copper, gold, and platinum. The application of the radiotracer method to these smooth surfaces have led to direct in-situ measurements from which surface coverage was determined; anions and molecules were identified; and weak interactions of adsorbates with the surface of the electrodes were readily monitored. 179 refs

  6. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    International Nuclear Information System (INIS)

    Ritschl, Ludwig; Fleischmann, Christof; Kuntz, Jan; Kachelrieß, Marc

    2016-01-01

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation

  7. The rotate-plus-shift C-arm trajectory. Part I. Complete data with less than 180° rotation

    Energy Technology Data Exchange (ETDEWEB)

    Ritschl, Ludwig; Fleischmann, Christof [Ziehm Imaging GmbH, Donaustraße 31, Nürnberg 90451 (Germany); Kuntz, Jan, E-mail: j.kuntz@dkfz.de; Kachelrieß, Marc [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120 (Germany)

    2016-05-15

    Purpose: In the last decade, C-arm-based cone-beam CT became a widely used modality for intraoperative imaging. Typically a C-arm CT scan is performed using a circular or elliptical trajectory around a region of interest. Therefore, an angular range of at least 180° plus fan angle must be covered to ensure a completely sampled data set. However, mobile C-arms designed with a focus on classical 2D applications like fluoroscopy may be limited to a mechanical rotation range of less than 180° to improve handling and usability. The method proposed in this paper allows for the acquisition of a fully sampled data set with a system limited to a mechanical rotation range of at least 180° minus fan angle using a new trajectory design. This enables CT like 3D imaging with a wide range of C-arm devices which are mainly designed for 2D imaging. Methods: The proposed trajectory extends the mechanical rotation range of the C-arm system with two additional linear shifts. Due to the divergent character of the fan-beam geometry, these two shifts lead to an additional angular range of half of the fan angle. Combining one shift at the beginning of the scan followed by a rotation and a second shift, the resulting rotate-plus-shift trajectory enables the acquisition of a completely sampled data set using only 180° minus fan angle of rotation. The shifts can be performed using, e.g., the two orthogonal positioning axes of a fully motorized C-arm system. The trajectory was evaluated in phantom and cadaver examinations using two prototype C-arm systems. Results: The proposed trajectory leads to reconstructions without limited angle artifacts. Compared to the limited angle reconstructions of 180° minus fan angle, image quality increased dramatically. Details in the rotate-plus-shift reconstructions were clearly depicted, whereas they are dominated by artifacts in the limited angle scan. Conclusions: The method proposed here employs 3D imaging using C-arms with less than 180° rotation

  8. Radioimmunoassay kit formulation and its validation for serum progesterone using progesterone radiotracer purified by gel filtration

    International Nuclear Information System (INIS)

    Karir, T.; Pal, N.; Sivaprasad, N.

    2003-01-01

    Purification of the radioiodinated progesterone tyrosine methyl ester conjugate by gel filtration and the development, optimization and clinical validation of a direct radioimmunoassay (RIA) of progesterone using this radiotracer are described. High purity radiotracer is essential for the error free performance of any RIA. Progesterone 11α hemisuccinate was conjugated to tyrosine methyl ester (TME) by the mixed anhydride method and this conjugate was then radioiodinated by the chloramine-T method. Purification of the radioiodinated product was carried out by gel filtration. About 12 batches of the radiotracer were prepared and purified. The purification by gel filtration gave reproducible elution pattern and purity. The radiotracer thus purified was found to have consistent quality as compared to that of any other purification methods. Non-specific binding of the radiotracer was found to be 95% as checked by paper electrophoresis. The stability (retention of the immunoreactivity) of the radiotracer was two to three months. No appreciable changes in the assay characteristics were observed during this period. The assay involved 3 hours incubation of progesterone antibody with individual standards or sample and radiotracer at room temperature. The optimized assay was then validated for internal and external quality control parameters. A RIA kit was then formulated with this radiotracer for estimation of progesterone in serum. The assay kit consisted of lyophilized individual standards ranging from 0.25 to 50 ng/ml. The clinical performance of the developed kit was compared with that of a commercial ELISA kit and a correlation of 0.94 was observed. (author)

  9. Asymmetric-cut variable-incident-angle monochromator.

    Science.gov (United States)

    Smither, R K; Graber, T J; Fernandez, P B; Mills, D M

    2012-03-01

    A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18° asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage (Φ) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation (Ψ) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation (Θ) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

  10. Leak detection in a high-pressure heat exchanger system in a refinery using radiotracer technique

    International Nuclear Information System (INIS)

    Samantray, J.S.; Sunil Goswami; Sharma, V.K.; Jayashree Biswal; Pant, H.J.

    2014-01-01

    A radiotracer investigation was carried out in a diesel hydrotreater (DHDT) unit in a refinery for leak detection in a breech-lock heat exchanger system. The main objectives of the study were to identify the leaking heat exchanger in a system with six heat exchangers and estimate the leak rate. Bromine-82 as dibromobiphenyl was selected and used as radiotracer for the investigation. The radiotracer was instantaneously injected into the suction end of the feed pump line to the heat exchanger of the DHDT unit. The movement of the tracer was measured at strategically selected locations using NaI(Tl) scintillation detectors. Based upon the results of the radiotracer investigation, it was found that out of six heat exchangers, exchanger E-1F was leaking. (author)

  11. Transformation of Real Spherical Harmonics under Rotations

    Science.gov (United States)

    Romanowski, Z.; Krukowski, St.; Jalbout, A. F.

    2008-08-01

    The algorithm rotating the real spherical harmonics is presented. The convenient and ready to use formulae for l = 0, 1, 2, 3 are listed. The rotation in R3 space is determined by the rotation axis and the rotation angle; the Euler angles are not used. The proposed algorithm consists of three steps. (i) Express the real spherical harmonics as the linear combination of canonical polynomials. (ii) Rotate the canonical polynomials. (iii) Express the rotated canonical polynomials as the linear combination of real spherical harmonics. Since the three step procedure can be treated as a superposition of rotations, the searched rotation matrix for real spherical harmonics is a product of three matrices. The explicit formulae of matrix elements are given for l = 0, 1, 2, 3, what corresponds to s, p, d, f atomic orbitals.

  12. Frequency-dependent squeeze-amplitude attenuation and squeeze-angle rotation by electromagnetically induced transparency for gravitational-wave interferometers

    International Nuclear Information System (INIS)

    Mikhailov, Eugeniy E.; Goda, Keisuke; Corbitt, Thomas; Mavalvala, Nergis

    2006-01-01

    We study the effects of frequency-dependent squeeze-amplitude attenuation and squeeze-angle rotation by electromagnetically induced transparency (EIT) on gravitational-wave (GW) interferometers. We propose the use of low-pass, bandpass, and high-pass EIT filters, an S-shaped EIT filter, and an intracavity EIT filter to generate frequency-dependent squeezing for injection into the antisymmetric port of GW interferometers. We find that the EIT filters have several advantages over the previous filter designs with regard to optical losses, compactness, and the tunability of the filter linewidth

  13. Assessing of bulk materials mixing and sorting by radiotracer methods

    International Nuclear Information System (INIS)

    Thyn, J.

    1983-01-01

    Various applications are indicated of tracer techniques for the evaluation of mixing and sorting of mixtures of solid particles. The evaluation of the process of mixing, i.e., the determination of the homogenization time is done by labelling of the entire volume of the monitored component of the mixture and continuous detection of radiation through the walls of the mixer using one or several detectors. The evaluation of the character of the flow and the evacuation of solid particles from the bin is done by labelling with a radiotracer the material which is spread out on the top along the whole cross-section of the bin, and the concentration is monitored of the tracer in the material outflow. The evaluation of material sorting in bins which takes place during the filling and emptying is done on the basis of significance tests or using self-correlation functions and frequency characteristics. Also monitored was the dependence of the equalizing ability of the continuous gravity mixer at the vertex angle of the tip. (M.D.)

  14. Application of Radiotracer Technology on Solving the Unsolved Leak in Lift Pit

    International Nuclear Information System (INIS)

    Mohd Fitri Abdul Rahman; Jaafar Abdullah; Hearie Hassan

    2016-01-01

    Radiotracers have been used in many fields to optimize processes, solve problems, improve product quality, save energy and reduce pollution. The radiotracer technology is a proven reliable technique and recognized by many sectors such as medical, industrial and environmental. In this work, an unsolved leak problem was present in lift pit within a building in Malaysia. Many techniques have applied such as dye techniques, chemical analyses and engineering plaster to overcome the problem. Unfortunately, none of the techniques solve the problem. Radiotracer was used to find the unidentified source of leak. Basically, Technetium (Tc-99m) has been injected to the several injection points and flow of the tracer was monitored with radiation detectors that have been placed at various locations. The results were successful and pinpoint the problems. (author)

  15. Radiographic femoral varus measurement is affected unpredictably by femoral rotation

    DEFF Research Database (Denmark)

    Miles, James Edward

    Radiographic measurements of femoral varus are used to determine if intervention to correct femoral deformity is required, and to calculate the required correction. The varus angle is defined as the angle between the proximal femoral long axis (PFLA) and an axis tangential to the distal femoral...... and externally by 5° and 10° using plastic wedges. Accuracy of rotation was within +1°. Digital radiographs were obtained at each position. Varus angles were measured using ImageJ, employing two definitions of PFLA. Mean varus angles increased with 10° of either internal or external rotation with both PFLA...... rotation angles. The effect of rotation on varus angle measurements in these femoral specimens contradicts a previous report using CT. The most probable explanation is the difference in femoral positioning: the CT study used a slightly elevated position compared to that in this study, resulting in better...

  16. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    Science.gov (United States)

    Sugiharto, Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-06-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  17. Radiotracer Dilution Method for Mercury Inventory Study in Electrolytic Cells

    International Nuclear Information System (INIS)

    Sugiharto; Su'ud, Zaki; Kurniadi, Rizal; Waris, Abdul; Santoso, Sigit Budi; Abidin, Zainal; Santoso, Gatot Budi

    2010-01-01

    Purpose of the experiment is to demonstrate feasibility the use of radiotracer to measure weight of mercury in electrolytic cells of soda industry. The weight of mercury in each cell of the plant is designed approximately 1700 kg. Radiotracer is prepared by mixing 203 Hg radioactive mercury with 2400 g of inactive mercury in a bath. The respective precisely weighted mercury aliquots to be injected into the cells are prepared by pouring approximately 130 g of radioactive mercury taken from the bath into 13 standard vials, in accordance with the number of the cells tested. Four standard references prepared by further dilution of ±2 g active mercury taken from the bath to obtain the dilution factors range of 12,000 to 20,000 from which the calibration graph is constructed. The injection process is conducting by pouring the radioactive mercury from aliquots into the flowing mercury at the inlet side of the cell and allows them to mix thoroughly. It is assumed that the mass of the radiotracer injected into a closed system remains constant, at least during the period of the test. From this experiment it was observed that the mixing time is two days after injection of radioactive mercury. The inactive mercury in each electrolytic cell calculated by the radiotracer method is of the range 1351.529 kg to 1966.354 kg with maximum error (95% confidence) is 1.52 %. The accuracy of measurement of the present method is better than gravimetric one which accounts 4 % of error on average.

  18. Research of pharmacokinetics of L-threonate calcium with 45Ca radiotrace

    International Nuclear Information System (INIS)

    Tong Jian; Niu Huisheng; Li Huaifen

    2001-01-01

    The pharmacokinetics of calcium in L-threonate calcium is studied by radiotrace method. The results show the relationship between drug-time curve, pharmacokinetics parameters and dosage are positive correlation, and calcium distributes in important tissues such as stomach, intestines, blood and bone. In 24 hours, about 40% calcium is drained in urine, 30% calcium is evacuated in feces, 10%-20% calcium deposit in blood or bone. The radiotrace method is a kind of special, sensitive, accurate method of testing calcium metabolism

  19. Influence of Radiographic Positioning on Canine Sacroiliac and Lumbosacral Angle Measurements.

    Science.gov (United States)

    Jones, Susan; Savage, Mason; Naughton, Brian; Singh, Susheela; Robertson, Ian; Roe, Simon C; Marcellin-Little, Denis J; Mathews, Kyle G

    2018-01-01

     To evaluate the influence of radiographic malpositioning on canine sacroiliac and lumbosacral inclination angles.  Using canine cadavers, lateral pelvic radiographs were acquired with the radiographic beam in a neutral position and then rotated 5, 10 and 15° to mimic rotational malpositioning. The focal point of the beam was then focused over the abdomen and again over mid-diaphysis of the femur to mimic an abdominal or femoral radiographic study.  Five degrees of rotational malpositioning did not influence measurements of sacroiliac or lumbosacral inclination, but malpositioning by more than 5° led to a significant decrease in both sacroiliac and lumbosacral angles. Moving the focal point to the femur significantly decreased the measured lumbosacral angle. Abdominally centred radiographs had no effect on lumbosacral and sacroiliac angle measurements.  When evaluating canine lumbosacral and sacroiliac angles radiographically, pelvic rotation of more than 5° should be avoided as should the use of lateral radiographs centred over the femur. Schattauer GmbH Stuttgart.

  20. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  1. Rotated balance in humans due to repetitive rotational movement

    Science.gov (United States)

    Zakynthinaki, M. S.; Madera Milla, J.; López Diaz De Durana, A.; Cordente Martínez, C. A.; Rodríguez Romo, G.; Sillero Quintana, M.; Sampedro Molinuevo, J.

    2010-03-01

    We show how asymmetries in the movement patterns during the process of regaining balance after perturbation from quiet stance can be modeled by a set of coupled vector fields for the derivative with respect to time of the angles between the resultant ground reaction forces and the vertical in the anteroposterior and mediolateral directions. In our model, which is an adaption of the model of Stirling and Zakynthinaki (2004), the critical curve, defining the set of maximum angles one can lean to and still correct to regain balance, can be rotated and skewed so as to model the effects of a repetitive training of a rotational movement pattern. For the purposes of our study a rotation and a skew matrix is applied to the critical curve of the model. We present here a linear stability analysis of the modified model, as well as a fit of the model to experimental data of two characteristic "asymmetric" elite athletes and to a "symmetric" elite athlete for comparison. The new adapted model has many uses not just in sport but also in rehabilitation, as many work place injuries are caused by excessive repetition of unaligned and rotational movement patterns.

  2. Rotated alphanumeric characters do not automatically activate frontoparietal areas subserving mental rotation

    DEFF Research Database (Denmark)

    Weiss, Michael M; Wolbers, Thomas; Peller, Martin

    2008-01-01

    Functional neuroimaging studies have identified a set of areas in the intraparietal sulcus and dorsal precentral cortex which show a linear increase in activity with the angle of rotation across a variety of mental rotation tasks. This linear increase in activity with angular disparity suggests t...... modulated by angular disparity during the stimulus categorization task. These results suggest that at least for alphanumerical characters, areas implicated in mental rotation will only be called into action if the task requires a rotational transformation....

  3. Diagnosing plant pipeline system performance using radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kasban, H.; Ali, Elsayed H.; Arafa, H. [Engineering Department, Nuclear Research Center, Atomic Energy Authority, Inshas (Egypt)

    2017-02-15

    This study presents an experimental work in a petrochemical company for scanning a buried pipeline using Tc{sup 99m} radiotracer based on the measured velocity changes, in order to determine the flow reduction along a pipeline. In this work, Tc{sup 99m} radiotracer was injected into the pipeline and monitored by sodium iodide scintillation detectors located at several positions along the pipeline. The flow velocity has been calculated between every two consecutive detectors along the pipeline. Practically, six experiments have been carried out using two different data acquisition systems, each of them being connected to four detectors. During the fifth experiment, a bypass was discovered between the scanned pipeline and another buried parallel pipeline connected after the injection point. The results indicate that the bypass had a bad effect on the volumetric flow rate in the scanned pipeline.

  4. SMAP Faraday Rotation

    Science.gov (United States)

    Le Vine, David

    2016-01-01

    Faraday rotation is a change in the polarization as signal propagates through the ionosphere. At L-band it is necessary to correct for this change and measurements are made on the spacecraft of the rotation angle. These figures show that there is good agreement between the SMAP measurements (blue) and predictions based on models (red).

  5. Cross polarization with phase and amplitude modulation of radio frequency fields in NMR-experiments with sample rotation at magic angle

    International Nuclear Information System (INIS)

    Dvinskij, S.V.; Chizhik, V.I.

    2006-01-01

    One analyzes cross polarization of nuclei within a rotating system of coordinates as applied to the NMR-experiments with a specimen rotation under the magic angle. One worded a concept of simultaneous phase and amplitude modulation according to which the Hamiltonian form of the restored dipole interaction persisted if inversion of difference of radiofrequency field amplitudes occurred simultaneously with phase inversion. One presents a theoretical substantiation in terms of the average Hamiltonian theory. The concept is demonstrated both experimentally and by means of numerical analysis for a number of special cases. Phase periodic inversion in cross polarized experiments is shown to result into practically important advantage of suppression of interactions of chemical shift and influence of effects of coarse adjustment of radiofrequency field parameters [ru

  6. Effect of limb rotation on radiographic alignment in total knee arthroplasties.

    Science.gov (United States)

    Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven

    2010-04-01

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic alignment after TKA and to establish a re-calculation of this rotation by using existing radiographic landmarks. Synthetic femur and tibia (Sawbones), Inc. Vashon Island, WA) were used to create a TKA of the Triathlon knee prosthesis system (Stryker), Limerick, Ireland). The femoral alignment was 6.5 degrees valgus. The model was fixed in an upright stand. Five series of nine anteroposterior (AP) long leg radiographs were taken on a 30 cm x 120 cm plates in full extension with the limb rotated, in 5 degrees increments, from 20 degrees external rotation to 20 degrees internal rotation. After digitizing each radiograph (Scanner Hewlett Packard XJ 527), an observer measured the anatomic mechanical angle of the femur [AMA ( degrees )], the mechanical lateral proximal femur angle [mLPFA ( degrees )], the mechanical lateral distal femur angle [mLDFA ( degrees )], the mechanical medial proximal tibia angle [mMPTA ( degrees )] and the mechanical lateral distal tibia angle [mLDTA ( degrees )] using a digital measurement software (MediCAD, Hectec, Altfraunhofen, Germany). Besides, the observer measured the geometrical distances of the femoral component figured on the long leg radiograph. A ratio of one distance to another was measured (called femoral component distance ratio). The average radiographic anatomic alignment ranged from 6.827 degrees AMA (SD = 0.22 degrees ) in 20 degrees internal rotation to 4.627 degrees AMA (SD = 0.22 degrees ) in 20 degrees external rotation. Average mLPFA ( degrees ) ranged from 101.63 degrees (SD = 0.63) in 20 degrees internal rotation to 93.60 degrees (SD = 0.74 degrees ) in 20 degrees external rotation. Average mLDFA ( degrees ) ranged from 90.59 degrees

  7. Radiotracer experiments and CFD simulation for industrial hydrocyclone performance

    International Nuclear Information System (INIS)

    Stegowski, Z.; Nowak, E.

    2007-01-01

    Hydrocyclone is a device for solid concentration or selection of solid particles from a liquid-solid mixture. It is widely used in the mineral industry for selection of solid particles from a few to a few hundred micrometers. This paper presents a radiotracer experiment and computational simulation of selection of solid particles in a hydrocyclone of Φ-500 μm, which is used in the industrial copper ore concentration process. The simulation, based on computational fluid dynamics (CFD) techniques, allowed obtaining the velocity and concentration distribution for a real mixture flowing in the hydrocyclone. The mixture was composed of water and nine solid phases of different grain sizes. Finally, the selection curve of solid grains was obtained and compared with the experimental radiotracer results. (author)

  8. Industrial applications of radiotracer and sealed source technology promoted by IAEA

    International Nuclear Information System (INIS)

    Joon-Ha Jin; Thereska, J.

    2004-01-01

    Great technical and economical benefits can be obtained by applying radioisotope technologies to various industries. The International Atomic Energy Agency (IAEA) has contributed to the development of radiotracer and sealed source technology as applied to industry and environment through coordinated research projects (CRPs). The mature and competitive techniques have been transferred and implemented to developing countries through the Agency's technical co-operation (TC) projects. The paper presents the main achievements in radiotracer and sealed source technology promoted by IAEA as well as the perspective of the technology transfer to developing countries. (author)

  9. The Impact of the Derotational Mobilization of Manual Therapy According to Kaltenborn-Evjenth on the Angle of Trunk Rotation in Patients with Adolescent Idiopathic Scoliosis--Pilot Study, Direct Observation.

    Science.gov (United States)

    Wnuk, Bartosz; Blicharska, Irmina; Błaszczak, Edward; Durmała, Jacek

    2015-01-01

    The use of manual therapy in the treatment of scoliosis has been controversial. Scientific reports do not clearly indicate its effectiveness or harmfulness. The aim of this study was to determine the effectiveness of passive and active derotation techniques of manual therapy according to Kaltenborn-Evjent on the reduction of the angle of trunk rotation in patients with idiopathic scoliosis. The study enrolled 33 female patients from the Department of Rehabilitation who were diagnosed with adolescent idiopathic scoliosis. The patients were divided into two groups according to the curve location (SRS classification). Group A consisted of 17 women, aged 14.±2.4 years, with single-curve scoliosis in the thoracolumbar segment and group B was composed of 16 women, aged 15±2.24 years, with double-curve scoliosis in the thoracic and lumbar segments. In both groups, the angle of trunk rotation, the magnitude of thoracic kyphosis and lumbar lordosis were measured twice, before and after each session of derotation techniques. Both groups demonstrated a positive impact of active and passive derotation techniques on the angle of trunk inclination. The greatest difference was observed after a session of active derotation in the patients with lumbar scoliosis. The angle of trunk rotation decreased on average by 4.5°±1.14°. No correlations were found between the curve angle values and the degree of thoracic derotation after the application of these techniques. Derotational mobilization techniques may be a valuable complement to scoliosis treatment methods as they increase their effectiveness.

  10. Titrating decision processes in the mental rotation task.

    Science.gov (United States)

    Provost, Alexander; Heathcote, Andrew

    2015-10-01

    Shepard and Metzler's (1971) seminal mental-rotation task-which requires participants to decide if 1 object is a rotated version of another or its mirror image-has played a central role in the study of spatial cognition. We provide the first quantitative model of behavior in this task that is comprehensive in the sense of simultaneously providing an account of both error rates and the full distribution of response times. We used Brown and Heathcote's (2008) model of choice processing to separate out the contributions of mental rotation and decision stages. This model-based titration process was applied to data from a paradigm where converging evidence supported performance being based on rotation rather than other strategies. Stimuli were similar to Shepard and Metzler's block figures except a long major axis made rotation angle well defined for mirror stimuli, enabling comprehensive modeling of both mirror and normal responses. Results supported a mental rotation stage based on Larsen's (2014) model, where rotation takes a variable amount of time with a mean and variance that increase linearly with rotation angle. Differences in response threshold differences were largely responsible for mirror responses being slowed, and for errors increasing with rotation angle for some participants. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  11. Rotation in a gravitational billiard

    Science.gov (United States)

    Peraza-Mues, G. G.; Carvente, Osvaldo; Moukarzel, Cristian F.

    Gravitational billiards composed of a viscoelastic frictional disk bouncing on a vibrating wedge have been studied previously, but only from the point of view of their translational behavior. In this work, the average rotational velocity of the disk is studied under various circumstances. First, an experimental realization is briefly presented, which shows sustained rotation when the wedge is tilted. Next, this phenomenon is scrutinized in close detail using a precise numerical implementation of frictional forces. We show that the bouncing disk acquires a spontaneous rotational velocity whenever the wedge angle is not bisected by the direction of gravity. Our molecular dynamics (MD) results are well reproduced by event-driven (ED) simulations. When the wedge aperture angle θW>π/2, the average tangential velocity Rω¯ of the disk scales with the typical wedge vibration velocity vb, and is in general a nonmonotonic function of the overall tilt angle θT of the wedge. The present work focuses on wedges with θW=2π/3, which are relevant for the problem of spontaneous rotation in vibrated disk packings. This study makes part of the PhD Thesis of G. G. Peraza-Mues.

  12. Development of stair-climbing mechanism with passive crawlers. Analysis of limitation for crawler rotation angle and test vehicle performance

    International Nuclear Information System (INIS)

    Hirasawa, Junji; Kimura, Tetsuya

    2016-01-01

    This paper describes a novel mechanism with passive crawlers that will realize a stair-climbing rescue robot with simple system. The proposed mechanism is called 'SMART-III', it is named after 'Simple Mechanism Adaptive for Rough Terrain'. Some quasi-static dynamic analysis were implemented and effectiveness of limitation for crawler rotation angle were verified. A prototype robot with the SMART-III mechanism had been improved. Experimental results show the effectiveness and performance of the proposed mechanism against a step and continuous stairs. (author)

  13. Rotational discontinuities in anisotropic plasmas

    International Nuclear Information System (INIS)

    Omidi, N.

    1992-01-01

    The kinetic structure of rotational discontinuities (RDs) in anisotropic plasmas with T perpendicular /T parallel > 1 is investigated by using a one-dimensional electromagnetic hybrid code. To form the RD, a new approach is used where the plasma is injected from one boundary and reflected from the other, resulting in the generation of a traveling fast shock and an RD. Unlike the previously used methods, no a priori assumptions are made regarding the initial structure (i.e. width or sense of rotation) of the rotational discontinuity. The results show that across the RD both the magnetic field strength and direction, as well as the plasma density change. Given that such a change can also be associated with an intermediate shock, the Rankine-Hugoniot relations are used to confirm that the observed structures are indeed RDs. It is found that the thickness of RDs is a few ion inertial lengths and is independent of the rotation angle. Also, the preferred sense of rotation is in the electron sense; however, RDs with a rotation angle larger than 180 degree are found to be unstable, changing their rotation to a stable ion sense

  14. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  16. Intra-operative nuclear imaging based on positron-emitting radiotracers

    International Nuclear Information System (INIS)

    Shakir, Dzhoshkun Ismail

    2014-01-01

    Positron-emitting radiotracers are an important part of nuclear medical imaging processes. Besides the very famous glucose analog [ 18 F]FDG, many not so well known ones exist, among them the particularly interesting amino acid-based tracers like [ 18 F]FET. Although peri-operative imaging with positron-emitting radiotracers has become state-of- the-art in cases of many types of cancer, their capability is not fully exploited in the operating room yet. In this thesis we explore two intra-operative nuclear imaging modalities exploiting different aspects of positron radiation towards quality assurance in challenging surgical treatment scenarios. The first modality freehand PET provides a tomographic image of a volume of interest and aims at minimizing invasiveness by assisting the surgeon in pinpointing target structures marked with a radiotracer. The second imaging modality epiphanography generates an image of the radiotracer distribution on a surface of interest and aims at providing a means for improving the control of tumor resection margins. The word epiphanography is a compound of the Greek words επιφανεια (epiphaneia) for surface and ζωγραφια (ographia) for image, and hence means the image of the surface similar to the compound τομοζ (tomos) for slice/volume and ζωγραφια (ographia) for image, meaning the image of the volume, i.e. tomography. To our knowledge this is the first use of the word epiphanography in the context of nuclear medical imaging. In this thesis we present our approach to modeling, developing and calibrating these two novel imaging modalities. In addition, we present our work towards their clinical integration. In the case of freehand PET, we have already acquired the first intra-operative datasets of a patient. We present this first experience in the operating room together with our phantom studies. In the case of epiphanography, we present our phantom studies with neurosurgeons towards the integration of this

  17. Optical fibre angle sensor used in MEMS

    International Nuclear Information System (INIS)

    Golebiowski, J; Milcarz, Sz; Rybak, M

    2014-01-01

    There is a need for displacement and angle measurements in many movable MEMS structures. The use of fibre optical sensors helps to measure micrometre displacements and small rotation angles. Advantages of this type of transducers are their simple design, high precision of processing, low costs and ability of a non-contact measurement. The study shows an analysis of a fibre-optic intensity sensor used for MEMS movable structure rotation angle measurement. An intensity of the light in the photodetector is basically dependent on a distance between a reflecting surface and a head surface of the fibre transmitting arm, and the deflection angle. Experimental tests were made for PMMA 980/1000 plastic fibres, Θ NA =33°. The study shows both analytical and practical results. It proves that calculated and experimental characteristics for the analysed transducers are similar.

  18. Development of equipment and radiotracer experiment using RI labelled sand in the coastal zone

    International Nuclear Information System (INIS)

    Choi, B. J.; Jung, S. H.; Kim, J. B.; Jin, J. H.

    2004-01-01

    On the basis of the radiotracer technology and the related equipments which have been developed for its industrial application through the nuclear long-term research project, a radiotracer study on sediment transport was carried out as a part of the development of the radiotracer technology for a coastal marine environment. The crystalline material doped with iridium having a similar composition and density as those of the bedload sand collected from the research area was produced by the oxide-route method. A radioisotope container was specially designed to inject the radiotracer from 1m above the sea bedload without radioactive contamination during the transport from the nuclear reactor at KAERI. The position data from the DGPS and the radiation measurement data are collected concurrently and stored by means of the application software programmed with the LabVIEW of the National Instrument. The position data is reprocessed to make it represent the real position of the radiation probe under water and not that of the DGPS antenna on board. In order to evaluate the influence of a breakwater on the deviation of the neighboring coastline, the time dependency of the spatial distribution of the sediment was studied in the area through three tracking measurements after the iridium glass was injected. This trial application showed the potential of the radiotracer technology as an important role for maintaining and developing the coastal marine environment in the future

  19. Rotationally invariant correlation filtering

    International Nuclear Information System (INIS)

    Schils, G.F.; Sweeney, D.W.

    1985-01-01

    A method is presented for analyzing and designing optical correlation filters that have tailored rotational invariance properties. The concept of a correlation of an image with a rotation of itself is introduced. A unified theory of rotation-invariant filtering is then formulated. The unified approach describes matched filters (with no rotation invariance) and circular-harmonic filters (with full rotation invariance) as special cases. The continuum of intermediate cases is described in terms of a cyclic convolution operation over angle. The angular filtering approach allows an exact choice for the continuous trade-off between loss of the correlation energy (or specificity regarding the image) and the amount of rotational invariance desired

  20. Photoelectron spectra of N2 +: Rotational line profiles studied with He;I endash excited angle-resolved spectroscopy and with synchrotron radiation

    International Nuclear Information System (INIS)

    Oehrwall, G.; Baltzer, P.; Bozek, J.

    1999-01-01

    We have recorded angle-resolved He I photoelectron spectra of the three outermost valence states in N 2 + , with high enough resolution to observe rotational line profiles. For the two Σ states, the X 2 Σ g + and the B 2 Σ u + , we found that the rotational branches corresponding to different changes in rotational quantum number can differ dramatically in β value. The well-known difference in β value for the ν=0 and ν=1 vibrations of the X 2 Σ g + state was found to be due to different rotational branching ratios and also different β values of the rotational branches. For the ν=0 endash 2 vibrations of the A 2 Π u state, the β value difference between rotational branches is much less pronounced than in the X and B states. We have also recorded synchrotron-radiation-excited photoelectron spectra of the ν=0 vibrational peaks of the X 2 Σ g + and B 2 Σ u + states where rotational line profiles are resolved. The intensities of the rotational branches were studied as function of photon energy, the X state between 23 and 65 eV, and the B state between 23 and 45 eV. The results for the X state have recently been presented in a Letter [G. Oehrwall, P. Baltzer, and J. Bozek, Phys. Rev. Lett. 81, 546, 1998]. The rotational branching ratios of the two states have very different behaviors as functions of photon energy. The relative intensities of the rotational branches in the X state change significantly over the studied energy range. The 3σ g →kσ u shape resonance apparently gives rise to a non-Franck-Condon-like behavior for the rotational branching ratio of the X state. In the B state, the rotational branching ratios remain essentially constant over the studied energy range. copyright 1999 The American Physical Society

  1. Research and development in radiotracer methodology and technology

    Energy Technology Data Exchange (ETDEWEB)

    Thereska, J. [International Atomic Energy Agency (IAEA), Vienna (Austria)

    2001-07-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  2. Research and development in radiotracer methodology and technology

    International Nuclear Information System (INIS)

    Thereska, J.

    2001-01-01

    An IAEA Coordinated Research Project (CRP) has promoted further the radiotracer technology, in particular has validated the residence time distribution (RTD) function in investigating many chemical engineering reactors, such as grinding mill and flotation cell, incinerator, crystallizer trickle bed reactor and waste water treatment units. (authors)

  3. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, Jose; Damera Martinez, A.; Ramos Espinosa, K.

    2003-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one a modified SRI, both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented Several trials performed simultaneously at the two Clarifiers demonstrated that the modified SRI was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The non-availability of a flow meter did not allow to extract more information related to some pattern flux anomalies, nevertheless, the radiotracer method was able to detect certain differences between the two clear juice outlet of the modified SRI Clarifier, probably due some problems in the construction of this equipment. This fact so as other goals achieved in this work, show once more the potentiality of the radiotracer method for this type of study related to the hydrodynamic characteristics of industrial facilities. (Author)

  4. A study of residence time distribution using radiotracer technique in the large scale plant facility

    Science.gov (United States)

    Wetchagarun, S.; Tippayakul, C.; Petchrak, A.; Sukrod, K.; Khoonkamjorn, P.

    2017-06-01

    As the demand for troubleshooting of large industrial plants increases, radiotracer techniques, which have capability to provide fast, online and effective detections to plant problems, have been continually developed. One of the good potential applications of the radiotracer for troubleshooting in a process plant is the analysis of Residence Time Distribution (RTD). In this paper, the study of RTD in a large scale plant facility using radiotracer technique was presented. The objective of this work is to gain experience on the RTD analysis using radiotracer technique in a “larger than laboratory” scale plant setup which can be comparable to the real industrial application. The experiment was carried out at the sedimentation tank in the water treatment facility of Thailand Institute of Nuclear Technology (Public Organization). Br-82 was selected to use in this work due to its chemical property, its suitable half-life and its on-site availability. NH4Br in the form of aqueous solution was injected into the system as the radiotracer. Six NaI detectors were placed along the pipelines and at the tank in order to determine the RTD of the system. The RTD and the Mean Residence Time (MRT) of the tank was analysed and calculated from the measured data. The experience and knowledge attained from this study is important for extending this technique to be applied to industrial facilities in the future.

  5. Green chemistry using radiotracers at SINP

    International Nuclear Information System (INIS)

    Lahiri, Susanta

    2006-01-01

    Green chemistry is utilization of set of principles, which restricts the use, or generation of hazardous substances. In this aim, it is necessary to develop alternative methods, or to find greener reagents for minimum utilization of environmentally hostile substances. Radiotracers can be effectively utilized for development of such methods. This article describes the current status of Green Chemistry research using accelerator/reactor produced radionuclides at Saha Institute of Nuclear Physics, Kolkata, India. (author)

  6. Factors affecting femoral rotational angle based on the posterior condylar axis in gap-based navigation-assisted total knee arthroplasty for valgus knee.

    Science.gov (United States)

    Lee, Sung-Sahn; Lee, Yong-In; Kim, Dong-Uk; Lee, Dae-Hee; Moon, Young-Wan

    2018-01-01

    Achieving proper rotational alignment of the femoral component in total knee arthroplasty (TKA) for valgus knee is challenging because of lateral condylar hypoplasia and lateral cartilage erosion. Gap-based navigation-assisted TKA enables surgeons to determine the angle of femoral component rotation (FCR) based on the posterior condylar axis. This study evaluated the possible factors that affect the rotational alignment of the femoral component based on the posterior condylar axis. Between 2008 and 2016, 28 knees were enrolled. The dependent variable for this study was FCR based on the posterior condylar axis, which was obtained from the navigation system archives. Multiple regression analysis was conducted to identify factors that might predict FCR, including body mass index (BMI), Kellgren-Lawrence grade (K-L grade), lateral distal femoral angles obtained from the navigation system and radiographs (NaviLDFA, XrayLDFA), hip-knee-ankle (HKA) axis, lateral gap under varus stress (LGVS), medial gap under valgus stress (MGVS), and side-to-side difference (STSD, MGVS - LGVS). The mean FCR was 6.1° ± 2.0°. Of all the potentially predictive factors evaluated in this study, only NaviLDFA (β = -0.668) and XrayLDFA (β = -0.714) predicted significantly FCR. The LDFAs, as determined using radiographs and the navigation system, were both predictive of the rotational alignment of the femoral component based on the posterior condylar axis in gap-based TKA for valgus knee. A 1° increment with NaviLDFA led to a 0.668° decrement in FCR, and a 1° increment with XrayLDFA led to a 0.714° decrement. This suggests that symmetrical lateral condylar hypoplasia of the posterior and distal side occurs in lateral compartment end-stage osteoarthritis with valgus deformity.

  7. The rotational elements of Mars and its satellites

    Science.gov (United States)

    Jacobson, R. A.; Konopliv, A. S.; Park, R. S.; Folkner, W. M.

    2018-03-01

    The International Astronomical Union (IAU) defines planet and satellite coordinate systems relative to their axis of rotation and the angle about that axis. The rotational elements of the bodies are the right ascension and declination of the rotation axis in the International Celestial Reference Frame and the rotation angle, W, measured easterly along the body's equator. The IAU specifies the location of the body's prime meridian by providing a value for W at epoch J2000. We provide new trigonometric series representations of the rotational elements of Mars and its satellites, Phobos and Deimos. The series for Mars are from a least squares fit to the rotation model used to orient the Martian gravity field. The series for the satellites are from a least squares fit to rotation models developed in accordance with IAU conventions from recent ephemerides.

  8. Rotational discontinuities and the structure of the magnetopause

    International Nuclear Information System (INIS)

    Swift, D.W.; Lee, L.C.

    1983-01-01

    Symmetric and asymmetric rotational discontinuities are studied by means of a one-dimensional computer simulation and by single-particle trajectory calculations. The numerical simulations show the symmetric rotation to be stable for both ion and electron senses of rotation with a thickness of the order of a few ion gyroradii when the rotation angle of the tangential field is 180 0 or less. Larger rotation angles tend to be unstable. In an expansive discontinuity, when the magnetic field on the downstream side of the discontinuity is larger, an expanding transition layer separating the high-field from a low-field region develops on the downstream side, and a symmetric rotational discontinuity forms at the upstream edge. The implication of these results for magnetopause structure and energy flow through the magnetopause is described

  9. On the stability of rotational discontinuities

    International Nuclear Information System (INIS)

    Richter, P.; Scholer, M.

    1989-01-01

    The stability of symmetric rotational discontinuities in which the magnetic field rotates by 180 degree is investigated by means of a one-dimensional self-consistent hybrid code. Rotational discontinuities with an angle Θ > 45 degree between the discontinuity normal direction and the upstream magnetic field are found to be relatively stable. The discontinuity normal is in the x direction and the initial magnetic field has finite y component only in the transition region. In the case of the ion (left-handed) sense of rotation of the tangential magnetic field, the transition region does not broaden with time. In the case of the electron (right-handed) sense of rotation, a damped wavetrain builds up in the B y component downstream of the rotational discontinuity and the discontinuity broadens with time. Rotational discontinuities with smaller angles, Θ, are unstable. Examples for a rotational discontinuity with Θ = 30 degree and the electron sense of rotation as well as a rotational discontinuity with Θ = 15 degree and the ion sense of rotation show that these discontinuities into waves. These waves travel approximately with Alfven velocity in the upstream direction and are therefore phase standing in the simulation system. The magnetic hodograms of these disintegrated discontinuities are S-shaped. The upstream portion of the hodogram is always right-handed; the downstream portion is always left-handed

  10. Studies on the electrochemical behaviour of iron by the use of radio-tracer technique, 1. Studies on the electrodeposition and dissolution of iron by the use of radio-tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Moritani, Kimikazu; Ito, Yasuhiko; Kamata, Masahiro; Oishi, Jun

    1984-12-01

    To investigate whether radio-tracer techniques can augment conventional electrochemical techniques, offering useful information about the electrochemical behaviour of iron, the current efficiency of the electrodeposition of iron and the corrosion rate of metallic iron were measured by the radio-tracer method and the results were compared with the results measured by gravimetry and absorption photometry. Major conclusions obtained by the experiments are summarized as: 1) Between ordinary Fe and /sup 59/Fe, no isotope effect was observed. 2) Radiation from /sup 59/Fe had no effect on the electrode reaction. 3) While the use of a Ge semiconductor detector is undoubtedly preferable, Geiger-Mueller counter or NaI(Tl) scintillation counter gave fully satisfactory results. 4) Electrodeposited iron corrodes several times more rapidly than the iron base metal. These results suggests many other interesting applications of the radio-tracer technique when it is desired to obtain more detailed information on the electrochemical behaviour of iron. (author).

  11. The structure of rotational discontinuities

    International Nuclear Information System (INIS)

    Neugebauer, M.

    1989-01-01

    This study examines the structures of a set of rotational discontinuities detected in the solar wind by the ISEE-3 spacecraft. It is found that the complexity of the structure increases as the angle θ between the propagation vector k and the magnetic field decreases. For rotational discontinuities that propagate at a large angle to the field with an ion (left-hand) sense of rotation, the magnetic hodograms tend to be flattened, in agreement with prior numerical simulations. When θ is large, angular overshoots are often observed at one or both ends of the discontinuity. When the propagation is nearly parallel to the field (i.e., when θ is small), many different types of structure are seen, ranging from straight lines, the S-shaped curves, to complex, disorganized shapes

  12. NMR system and method having a permanent magnet providing a rotating magnetic field

    Science.gov (United States)

    Schlueter, Ross D [Berkeley, CA; Budinger, Thomas F [Berkeley, CA

    2009-05-19

    Disclosed herein are systems and methods for generating a rotating magnetic field. The rotating magnetic field can be used to obtain rotating-field NMR spectra, such as magic angle spinning spectra, without having to physically rotate the sample. This result allows magic angle spinning NMR to be conducted on biological samples such as live animals, including humans.

  13. Effects of Angle of Rotation on Pool Boiling Heat Transfer of V-shape Tube Bundle

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Myeong-Gie [Andong National University, Andong (Korea, Republic of)

    2016-10-15

    The most important facility for the systems is a passive heat exchanger that transfers core decay heat to the cold water in a water storage tank under atmospheric pressure. Since the space for the installation of the heat exchanger is usually limited, developing more efficient heat exchangers is important. In general, pool boiling is generated on the surface of the heat exchanging tube. The major design parameter of the heat exchanger is a tube arrangement. The upper tube is affected by the lower tube and the enhancement of the heat transfer on the upper tube is estimated by the bundle effect. Since heat transfer is related to the conditions of a tube surface, bundle geometries, and a liquid type, lots of studies have been carried out for the combinations of those parameters. An experimental study was performed to investigate the effects of the angle of rotation on pool boiling heat transfer of a V-shape tube bundle. For the test, two smooth stainless steel tubes of 19 mm outside diameter and the water at atmospheric pressure were used. The enhancement of the heat transfer is clearly observed when the angle becomes to 90° where the upper tube has the maximum region of influence by the lower tube. The convective flow and liquid agitation enhance heat transfer while the coalescence of the bubbles deteriorates heat transfer.

  14. Angle measures, general rotations, and roulettes in normed planes

    Science.gov (United States)

    Balestro, Vitor; Horváth, Ákos G.; Martini, Horst

    2017-12-01

    In this paper a special group of bijective maps of a normed plane (or, more generally, even of a plane with a suitable Jordan curve as unit circle) is introduced which we call the group of general rotations of that plane. It contains the isometry group as a subgroup. The concept of general rotations leads to the notion of flexible motions of the plane, and to the concept of Minkowskian roulettes. As a nice consequence of this new approach to motions the validity of strong analogues to the Euler-Savary equations for Minkowskian roulettes is proved.

  15. The Effects of Visual Discriminability and Rotation Angle on 30-Month-Olds' Search Performance in Spatial Rotation Tasks.

    Science.gov (United States)

    Ebersbach, Mirjam; Nawroth, Christian

    2016-01-01

    Tracking objects that are hidden and then moved is a crucial ability related to object permanence, which develops across several stages in early childhood. In spatial rotation tasks, children observe a target object that is hidden in one of two or more containers before the containers are rotated around a fixed axis. Usually, 30-month-olds fail to find the hidden object after it was rotated by 180°. We examined whether visual discriminability of the containers improves 30-month-olds' success in this task and whether children perform better after 90° than after 180° rotations. Two potential hiding containers with same or different colors were placed on a board that was rotated by 90° or 180° in a within-subjects design. Children ( N = 29) performed above chance level in all four conditions. Their overall success in finding the object did not improve by differently colored containers. However, different colors prevented children from showing an inhibition bias in 90° rotations, that is, choosing the empty container more often when it was located close to them than when it was farther away: This bias emerged in the same colors condition but not in the different colors condition. Results are discussed in view of particular challenges that might facilitate or deteriorate spatial rotation tasks for young children.

  16. The effects of visual discriminability and rotation angle on 30-month-olds’ search performance in spatial rotation tasks

    Directory of Open Access Journals (Sweden)

    Mirjam Ebersbach

    2016-10-01

    Full Text Available Tracking objects that are hidden and then moved is a crucial ability related to object permanence, which develops across several stages in early childhood. In spatial rotation tasks, children observe a target object that is hidden in one of two or more containers before the containers are rotated around a fixed axis. Usually, 30-month-olds fail to find the hidden object after it was rotated by 180°. We examined whether visual discriminability of the containers improves 30-month-olds’ success in this task and whether children perform better after 90° than after 180° rotations. Two potential hiding containers with same or different colors were placed on a board that was rotated by 90° or 180° in a within-subjects design. Children (N = 29 performed above chance level in all four conditions. Their overall success in finding the object did not improve by differently colored containers. However, different colors prevented children from showing an inhibition bias in 90° rotations, that is, choosing the empty container more often when it was located close to them than when it was farther away: This bias emerged in the same colors condition but not in the different colors condition. Results are discussed in view of particular challenges that might facilitate or deteriorate spatial rotation tasks for young children.

  17. The Effects of Visual Discriminability and Rotation Angle on 30-Month-Olds’ Search Performance in Spatial Rotation Tasks

    Science.gov (United States)

    Ebersbach, Mirjam; Nawroth, Christian

    2016-01-01

    Tracking objects that are hidden and then moved is a crucial ability related to object permanence, which develops across several stages in early childhood. In spatial rotation tasks, children observe a target object that is hidden in one of two or more containers before the containers are rotated around a fixed axis. Usually, 30-month-olds fail to find the hidden object after it was rotated by 180°. We examined whether visual discriminability of the containers improves 30-month-olds’ success in this task and whether children perform better after 90° than after 180° rotations. Two potential hiding containers with same or different colors were placed on a board that was rotated by 90° or 180° in a within-subjects design. Children (N = 29) performed above chance level in all four conditions. Their overall success in finding the object did not improve by differently colored containers. However, different colors prevented children from showing an inhibition bias in 90° rotations, that is, choosing the empty container more often when it was located close to them than when it was farther away: This bias emerged in the same colors condition but not in the different colors condition. Results are discussed in view of particular challenges that might facilitate or deteriorate spatial rotation tasks for young children. PMID:27812346

  18. A Viewpoint on the Quantity "Plane Angle"

    Science.gov (United States)

    Eder, W. E.

    1982-01-01

    Properties of the quantity "plane angle" are explored under the hypothesis that it is a dimensional quantity. The exploration proceeds especially with respect to the physical concept, its mathematical treatment, vector concepts, measurement theory, units of related quantities, engineering pragmatism, and SI. An attempt is made to bring these different relations into a rational, logical and consistent framework, and thus to justify the hypothesis. Various types of vectorial quantities are recognized, and their properties described with an outline of the necessary algebraic manipulations. The concept of plane angle is amplified, and its interdependence with the circular arc is explored. The resulting units of plane angle form a class of similar scales of measurement. Consequences of the confirmed hypothesis are developed for mathematical expressions involving trigonometric functions, rotational volumes and areas, mathematical limits, differentiation and series expansion. Consequences for mechanical rotational quantities are developed, with proposals for revisions to a number of expressions for derived units within SI. A revised definition for the quantity "plane angle" is stated to take account of the developed insights. There is a clear need to reconsider the status of plane angle and some other quantities within the international framework of SI.

  19. Applications of radiotracer techniques for the toxicology studies of nanomaterials

    International Nuclear Information System (INIS)

    Ma Yuhui; Zhang Zhiyong; Zhang Yuan; He Xiao; Zhang Haifeng; Chai Zhifang

    2008-01-01

    With the rapid development of nanosciences and nanotechnology, a wide variety of manufactured nanomaterials are now used in commodities, pharmaceutics, cosmetics, biomedical products, and industries. While nanomaterials possess more novel and unique physicochemical properties than bulk materials, they also have an unpredictable impact on human health. In the toxicology studies of nanomaterials, it is essential to know the basic behaviors in vivo, that is absorption, distribution, metabolism, and excretion (ADME) of these newly designed materials. Radiotracer techniques are especially well suited to such studies and has got the chance to demonstrate its enchantment. In this presentation, studies on radiotracer techniques used in nanotoxicology will be reviewed and new progresses at Institute of High Energy Physics, including the label methods and behaviors of labeled nanomaterials, such as fullerene, carbon nanotubes, and nanometer metal oxide in animals and in aquatic environments will be reported. (authors)

  20. Inception mechanism and suppression of rotating stall in an axial-flow fan

    International Nuclear Information System (INIS)

    Nishioka, T

    2013-01-01

    Inception patterns of rotating stall at two stagger-angle settings for the highly loaded rotor blades were experimentally investigated in a low-speed axial-flow fan. Rotor-tip flow fields were also numerically investigated to clarify the mechanism behind the rotating stall inception. The stall inception patterns depended on the rotor stagger-angle settings. The stall inception from a rotating instability was confirmed at the design stagger-angle settings. The stall inception from a short length-scale stall cell (spike) was also confirmed at the small stagger-angle setting. The spillage of tip-leakage flow and the tip-leakage vortex breakdown influence the rotating stall inception. An air-separator has been developed based on the clarified inception mechanism of rotating stall. The rotating stall was suppressed by the developed air-separator, and the operating range of fan was extended towards low flow rate. The effect of developed air-separator was also confirmed by application to a primary air fan used in a coal fired power plant. It is concluded from these results that the developed air-separator can provide a wide operating range for an axial-flow fan

  1. Rotational Angles and Velocities During Down the Line and Diagonal Across Court Volleyball Spikes

    Directory of Open Access Journals (Sweden)

    Justin R. Brown

    2014-05-01

    Full Text Available The volleyball spike is an explosive movement that is frequently used to end a rally and earn a point. High velocity spikes are an important skill for a successful volleyball offense. Although the influence of vertical jump height and arm velocity on spiked ball velocity (SBV have been investigated, little is known about the relationship of shoulder and hip angular kinematics with SBV. Other sport skills, like the baseball pitch share similar movement patterns and suggest trunk rotation is important for such movements. The purpose of this study was to examine the relationship of both shoulder and hip angular kinematics with ball velocity during the volleyball spike. Methods: Fourteen Division I collegiate female volleyball players executed down the line (DL and diagonally across-court (DAC spikes in a laboratory setting to measure shoulder and hip angular kinematics and velocities. Each spike was analyzed using a 10 Camera Raptor-E Digital Real Time Camera System.  Results: DL SBV was significantly greater than for DAC, respectively (17.54±2.35 vs. 15.97±2.36 m/s, p<0.05.  The Shoulder Hip Separation Angle (S-HSA, Shoulder Angular Velocity (SAV, and Hip Angular Velocity (HAV were all significantly correlated with DAC SBV. S-HSA was the most significant predictor of DAC SBV as determined by regression analysis.  Conclusions: This study provides support for a relationship between a greater S-HSA and SBV. Future research should continue to 1 examine the influence of core training exercise and rotational skill drills on SBV and 2 examine trunk angular velocities during various types of spikes during play.

  2. Hydrogen and deuterium NMR of solids by magic-angle spinning

    International Nuclear Information System (INIS)

    Eckman, R.R.

    1982-10-01

    The nuclear magnetic resonance of solids has long been characterized by very large specral broadening which arises from internuclear dipole-dipole coupling or the nuclear electric quadrupole interaction. These couplings can obscure the smaller chemical shift interaction and make that information unavailable. Two important and difficult cases are that of hydrogen and deuterium. The development of cross polarization, heteronuclear radiofrequency decoupling, and coherent averaging of nuclear spin interactions has provided measurement of chemical shift tensors in solids. Recently, double quantum NMR and double quantum decoupling have led to measurement of deuterium and proton chemical shift tensors, respectively. A general problem of these experiments is the overlapping of the tensor powder pattern spectra of magnetically distinct sites which cannot be resolved. In this work, high resolution NMR of hydrogen and deuterium in solids is demonstrated. For both nuclei, the resonances are narrowed to obtain liquid-like isotropic spectra by high frequency rotation of the sample about an axis inclined at the magic angle, β/sub m/ = Arccos (3/sup -1/2/), with respect to the direction of the external magnetic field. For deuterium, the powder spectra were narrowed by over three orders of magnitude by magic angle rotation with precise control of β. A second approach was the observation of deuterium double quantum transitions under magic angle rotation. For hydrogen, magic angle rotation alone could be applied to obtain the isotropic spectrum when H/sub D/ was small. This often occurs naturally when the nuclei are semi-dilute or involved in internal motion. In the general case of large H/sub D/, isotropic spectra were obtained by dilution of 1 H with 2 H combined with magic angle rotation. The resolution obtained represents the practical limit for proton NMR of solids

  3. Challenges in the development of dopamine D2- and D3-selective radiotracers for PET imaging studies.

    Science.gov (United States)

    Mach, Robert H; Luedtke, Robert R

    2018-03-01

    The dopamine D2-like receptors (ie, D2/3 receptors) have been the most extensively studied CNS receptor with Positron Emission Tomography (PET). The 3 different radiotracers that have been used in these studies are [ 11 C]raclopride, [ 18 F]fallypride, and [ 11 C]PHNO. Because these radiotracers have a high affinity for both dopamine D2 and D3 receptors, the density of dopamine receptors in the CNS is reported as the D2/3 binding potential, which reflects a measure of the density of both receptor subtypes. Although the development of D2- and D3-selective PET radiotracers has been an active area of research for many years, this by and large presents an unmet need in the area of translational PET imaging studies. This article discusses some of the challenges that have inhibited progress in this area of research and the current status of the development of subtype selective radiotracers for imaging D3 and D2 dopamine receptors with PET. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Power dependence on the rotational strength in a quartz crystal

    International Nuclear Information System (INIS)

    Joshi, N.V.; Salcedo, D.; Gil, H.

    2007-01-01

    The rotational strength of optical activity has been examined as a function of power of the incident radiation in a quartz crystal for the first time. It has been observed that the angle of rotation is proportional to the square root of the intensity of the radiation. The present experimental data directly support the recently proposed model which takes into account the electronic polarizability rather than the atomic polarizability. This model explicitly explains the role of the incident power in estimating the angle of rotation

  5. Application of 99mTc-DTPA Radiotracer in Persian Cat's Renal ...

    African Journals Online (AJOL)

    Keywords: Kidney, Persian cat, Radiotracer, Scintigraphy, Technetium-99m diethylene triamine pentacaetic acid ... tracer can be detected in the body by medical equipment .... studies, such as kidney failure, allergic reactions and fatal side ...

  6. Extraction of the wake induction and angle of attack on rotating wind turbine blades from PIV and CFD results

    Directory of Open Access Journals (Sweden)

    I. Herráez

    2018-01-01

    Full Text Available The analysis of wind turbine aerodynamics requires accurate information about the axial and tangential wake induction as well as the local angle of attack along the blades. In this work we present a new method for obtaining them conveniently from the velocity field. We apply the method to the New Mexico particle image velocimetry (PIV data set and to computational fluid dynamics (CFD simulations of the same turbine. This allows the comparison of experimental and numerical results of the mentioned quantities on a rotating wind turbine. The presented results open up new possibilities for the validation of numerical rotor models.

  7. Distributed microprocessor automation network for synthesizing radiotracers used in positron emission tomography

    International Nuclear Information System (INIS)

    Russell, J.A.G.; Alexoff, D.L.; Wolf, A.P.

    1984-01-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. 20 refs. (DT)

  8. Radiotracer technique to predict irritation potential of soap

    International Nuclear Information System (INIS)

    Castaneda, S.S.; Garcia, T.Y.; Santos, F.L.

    1990-01-01

    The application of a radiotracer technique using tritiated water to predict the irritation potentials of some soap products is demonstrated. Collagen films are treated with 0.5% and 1.0% soap solutions and tritiated water then incubated at 50 degrees centigrade for 24 hours. After incubation, the uptake of tritiated water by the collagen films was measured by liquid scintillation counting. (Auth.). 6 refs., 2 tabs

  9. An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

    International Nuclear Information System (INIS)

    Lin, Yuan; Samei, Ehsan; Ramirez-Giraldo, Juan Carlos; Gauthier, Daniel J.; Stierstorfer, Karl

    2014-01-01

    Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure

  10. Actuator assembly including a single axis of rotation locking member

    Science.gov (United States)

    Quitmeyer, James N.; Benson, Dwayne M.; Geck, Kellan P.

    2009-12-08

    An actuator assembly including an actuator housing assembly and a single axis of rotation locking member fixedly attached to a portion of the actuator housing assembly and an external mounting structure. The single axis of rotation locking member restricting rotational movement of the actuator housing assembly about at least one axis. The single axis of rotation locking member is coupled at a first end to the actuator housing assembly about a Y axis and at a 90.degree. angle to an X and Z axis providing rotation of the actuator housing assembly about the Y axis. The single axis of rotation locking member is coupled at a second end to a mounting structure, and more particularly a mounting pin, about an X axis and at a 90.degree. angle to a Y and Z axis providing rotation of the actuator housing assembly about the X axis. The actuator assembly is thereby restricted from rotation about the Z axis.

  11. Impurity analysis in EC-99mTC radiotracer using chromatographic techniques

    International Nuclear Information System (INIS)

    Almeida, E.V.; Fukumori, N.T.O.; Mengatti, J.; Silva, C.P.G.; Matsuda, M.M.N.

    2008-01-01

    The objective of this study was to develop two chromatographic methods of impurity analysis in radiotracer 99m Tc-EC: the Thin Layer Chromatography (TLC) and the High Performance Liquid Chromatography Reversed Phase (HPLC-RP)

  12. Synthesis and marking with technetium and rhenium of a new radiotracer from para-toluidine

    International Nuclear Information System (INIS)

    Laouini, Emna

    2011-01-01

    The development of nuclear medicine is based on the research of new radiotracers especially those which target the neuro degenerative diseases. In fact, the precocious diagnostic of these diseases using the radiopharmaceuticals is the only mean to defeat it. The biodistribution of a new cytectrene derivative from para-toluidine, having a lipophilic character and a low molecular weight, showed a new radiotracer which is able to clear the blood brain barrier and characterised with prolonged brain retention. The features of this complex contribute to make it a radiopharmaceutical to diagnostic aim in clinical use.

  13. Synthesis of a new technetium brain radiotracer

    International Nuclear Information System (INIS)

    El Aissi, Radhia

    2009-01-01

    The radiological diagnosis of brain diseases, including neurodegenerative ones, is still difficult because of the absence of specific biological markers. These diseases are then increasingly the subject of researches and new experiments. The biodistribution of a new cytectrenes-aniline derivative, having a lipophilic character and low molecular weight, showed a prolonged brain retention and a specific tissue distribution of the hippocampus. This radiotracer could contribute to establish early diagnosis of neurodegenerative diseases thanks to its affinity with a serotonin receptors-rich region. (Author)

  14. Increased bone radiotracer uptake in renal osteodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    de Graaf, P.; Schicht, I.M.; de Graeff, J.; te Velde, J.; Kleiverda, K.; Pauwels, E.K.J.

    1982-04-01

    Bone radiotracer uptake in renal osteodystrophy was investigated in 35 dialysis patients by correlating the results of quantitative bone scintigraphy with those of biochemical and bone morphometric studies. There were highly significant correlations (P < 0.001) between the total skeletal activity and the biochemical (iPTH and alkaline phosphatase), and histologic parameters of hyperparathyroidism. These clinical results strongly suggest that increased bone turnover i.e. hyperparathyroidism, rather than osteomalacia is the major cause of increased skeletal uptake in renal osteodystrophy.

  15. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M., E-mail: anacamiqui@gmail.com, E-mail: egoncalves@con.ufrj.br, E-mail: brandao@ien.gov.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  16. Fluid flow profile in a packed bead column using residence time curves and radiotracer techniques

    International Nuclear Information System (INIS)

    Almeida, Ana Paula F. de; Gonçalves, Eduardo Ramos; Brandão, Luis Eduardo B.; Salgado, Cesar M.

    2017-01-01

    Filling columns are extremely important in the chemical industry and are used for purification, separation and treatment processes of gas or liquid mixtures. The objective of this work is to study the hydrodynamics of the fluid for a characterization of aqueous phase flow patterns in the filling column, associating with the methodology of the Curves of Residence Time Distribution (RTD) to analyze and associate theoretical models that put as conditions column operating. RTD can be obtained by using the pulse-stimulus response technique which is characterized by the instantaneous injection of a radiotracer into the system input. In this work, 68Ga was used as radiotracer. Five shielded and collimated NaI (Tl) 1 x 1″ scintillator detectors were suitably positioned to record the movement of the radiotracer's path in the conveying line and filling column. Making possible the analysis of the RTD curve in the regions of interest. With the data generated by the NaI (Tl) detectors with the passage of the radiotracer in the transport line and inside the column, it was possible to evaluate the flow profile of the aqueous phase and to identify operational failures, such as internal conduit and the existence of a retention zone in the inside the column. Theoretical models were used for different flow flows: the piston flow and perfect mixing. (author)

  17. Residence time distribution measurements in a pilot-scale poison tank using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Goswami, Sunil; Samantray, J S; Sharma, V K; Maheshwari, N K

    2015-09-01

    Various types of systems are used to control the reactivity and shutting down of a nuclear reactor during emergency and routine shutdown operations. Injection of boron solution (borated water) into the core of a reactor is one of the commonly used methods during emergency operation. A pilot-scale poison tank was designed and fabricated to simulate injection of boron poison into the core of a reactor along with coolant water. In order to design a full-scale poison tank, it was desired to characterize flow of liquid from the tank. Residence time distribution (RTD) measurement and analysis was adopted to characterize the flow dynamics. Radiotracer technique was applied to measure RTD of aqueous phase in the tank using Bromine-82 as a radiotracer. RTD measurements were carried out with two different modes of operation of the tank and at different flow rates. In Mode-1, the radiotracer was instantaneously injected at the inlet and monitored at the outlet, whereas in Mode-2, the tank was filled with radiotracer and its concentration was measured at the outlet. From the measured RTD curves, mean residence times (MRTs), dead volume and fraction of liquid pumped in with time were determined. The treated RTD curves were modeled using suitable mathematical models. An axial dispersion model with high degree of backmixing was found suitable to describe flow when operated in Mode-1, whereas a tanks-in-series model with backmixing was found suitable to describe flow of the poison in the tank when operated in Mode-2. The results were utilized to scale-up and design a full-scale poison tank for a nuclear reactor. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Distributed Microprocessor Automation Network for Synthesizing Radiotracers Used in Positron Emission Tomography [PET

    Science.gov (United States)

    Russell, J. A. G.; Alexoff, D. L.; Wolf, A. P.

    1984-09-01

    This presentation describes an evolving distributed microprocessor network for automating the routine production synthesis of radiotracers used in Positron Emission Tomography. We first present a brief overview of the PET method for measuring biological function, and then outline the general procedure for producing a radiotracer. The paper identifies several reasons for our automating the syntheses of these compounds. There is a description of the distributed microprocessor network architecture chosen and the rationale for that choice. Finally, we speculate about how this network may be exploited to extend the power of the PET method from the large university or National Laboratory to the biomedical research and clinical community at large. (DT)

  19. Hydrodynamic characteristics of high speed settling clarifiers by radiotracer method

    International Nuclear Information System (INIS)

    Griffith Martinez, J.; Flores Juan, P.; Cuesta Borges, J.; Damera Martinez, A.; Ramos Espinosa, K. A

    2005-01-01

    Results achieved in the evaluation of two high-speed settling cane juice Clarifiers, one denominated ICINAZ The Express and the other one with Low Residence Time (BTR), both located at the sugar factory Orlando Gonzalez employing the well established radiotracer method (Tc-99m) are presented. Several trials performed at the two Clarifiers demonstrated that the one identified as BTR was capable to assimilate the whole flow capacity of the factory with adequate characteristic of the pattern flux and residence time in the environment of 1 hour. In the other side, ICINAZ The Express Clarifier could only work at relative low flow capacity of the factory with residence time closely to the two hours and achieving occasionally a pattern flux seriously affected by fluctuations in the milling process. The radiotracer method was able to detect certain differences between the two clear juice outlet of the BTR Clarifier, probably due some problems in the construction of this equipment

  20. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  1. Radiotracer technology as applied to industry. Final report of a co-ordinated research project 1997-2000

    International Nuclear Information System (INIS)

    2001-12-01

    The Co-ordinated Research Project (CRP) on Radiotracer Technology for Engineering Unit Operation Studies and Unit Process Optimization was carried out by the International Atomic Energy Agency (IAEA) from December 1997 until December 2000. The project developed and validated procedures and protocols for investigation of major industrial processes, including fluidized beds, sugar crystallizers, trickle bed reactors, cement rotary kilns, flotation cells, grinding mills, incinerators, wastewater treatment units and interwell communications in oil fields. This publication is the output of the above mentioned CRP. It provides the principles and state of the art of radiotracer methodology and technology as applied to industry and environment. It is expected to provide wider interest for further development of skills and confidence prior to carrying out field work. It facilitates transfer of technology from developed to developing countries and from nuclear research institutions to industrial end users. The publication could be a suitable guide for radiotracer applications in almost all types of process investigations. The case studies described in this publication deal with typical problems in industry and environment common to all countries. It is intended for radiotracer groups as well as for end engineers and managers from chemical and petrochemical industries, mineral ore and raw material processing, wastewater treatment plants, and other industrial sectors

  2. One-dimensional low spatial frequency LIPSS with rotating orientation on fused silica

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Simon, E-mail: simon.schwarz@h-ab.de; Rung, Stefan; Hellmann, Ralf

    2017-07-31

    Highlights: • Generation of one-dimensional low spatial frequency LIPSS on transparent material. • Varying the angle of incidence results in a rotation of the one-dimensional LSFL. • Rotation angle of LSFL decreases with increasing the applied fluence. • Orientation of the LSFL is mirror-inverted when reversing the scanning direction. - Abstract: We report on the generation of one-dimensional low spatial frequency LIPSS on transparent material. The influence of the applied laser fluence and angle of incidence on the periodicity, orientation and quality of the one-dimensional low spatial frequency LIPSS is investigated, facilitating the generation of highly uniform LIPSS alongside a line. Most strikingly, however, we observe a previously unreported effect of a pronounced rotation of the one-dimensional low spatial frequency LIPSS for varying angle of incidence upon inclined laser irradiation.

  3. Estimation of shell thickness in a continuously cast steel billet using radiotracers

    International Nuclear Information System (INIS)

    Prasad, A.S.; Pandey, J.C.; Kaur, G.

    1994-01-01

    In the continuous casting of steel, one of the factors which limits the rate of faster withdrawal of the casting from the mould is the thickness of the solid shell below the mould. If the shell can not contain the liquid pool, breakouts occur and process of casting disrupts. Estimates of shell thickness have been made on the basis of heat- transfer considerations. The shell thickness could also be delineated, to some extent, by adding radiotracers during casting and subsequently determining the dispersion of radioactivity by autoradiography. The paper presents the results of the estimation of shell thickness based on the heat-transfer model and validation of the model by plant trials using radiotracers. (author). 11 refs., 5 figs., 1 tab

  4. Roentgenographic evaluation of the actual CCD and AT angle. Pt. 2

    International Nuclear Information System (INIS)

    Brueckl, R.; Grunert, S.; Rosemeyer, B.

    1986-01-01

    The method developed by Rippstein and Mueller allows a mathematically exact determination of the femoral neck-shaft angle (CCD) and the angle of torsion (AT); already at a deviation of 5-10 0 from the prescribed position of the patient considerable errors (up to more than 15 0 ) may occur. For this reason two alternative methods are cited and described in detail: a) the cinematographic determination of the CCD- and AT-angle according to Schwetlick, and b) the combination of the determination of the AT-angle in exterior rotation according to Rogers and an anteroposterior roentgenogram of the pelvis and hips in interior rotation of the size of the AT-angle. Both methods are also mathematically exact, however, in addition almost independent from minor deviations in the position of the patient. It is advisable to apply one of the cited methods in cases of high AT-angle values (>>30 0 ), in cases where the placing of the patient is difficult and where the determination of the angles would require a major therapeutic measurement. (orig.) [de

  5. Gender differences in rotation of the shank during single-legged drop landing and its relation to rotational muscle strength of the knee.

    Science.gov (United States)

    Kiriyama, Shinya; Sato, Haruhiko; Takahira, Naonobu

    2009-01-01

    Increased shank rotation during landing has been considered to be one of the factors for noncontact anterior cruciate ligament injuries in female athletes. There have been no known gender differences in rotational knee muscle strength, which is expected to inhibit exaggerated shank rotation. Women have less knee external rotator strength than do men. Lower external rotator strength is associated with increased internal shank rotation at the time of landing. Controlled laboratory study. One hundred sixty-nine healthy young subjects (81 female and 88 male; age, 17.0 +/- 1.0 years) volunteered to participate in this study. The subjects performed single-legged drop landings from a 20-cm height. Femoral and shank kinematics were measured using a 3D optoelectronic tracking system during the drop landings, and then the joint angles around the knee (flexion/extension, valgus/varus, and internal/external rotation) were calculated. The maximal isometric rotational muscle strength of the knee was measured at 30 degrees of knee flexion in a supine position using a dynamometer. The female subjects had significantly less external shank rotation strength than did the male subjects (P external rotation strength and the peak shank internal rotation angle during landing (r = -0.322, P external rotator strength. This may lead to large shank internal rotation movement during the single-legged drop landing. Improving strength training of the external rotator muscle may help decrease the rates of anterior cruciate ligament injury in female athletes.

  6. Critical Shoulder Angle and Acromial Index Do Not Influence 24-Month Functional Outcome After Arthroscopic Rotator Cuff Repair.

    Science.gov (United States)

    Lee, Merrill; Chen, Jerry Yongqian; Liow, Ming Han Lincoln; Chong, Hwei Chi; Chang, Paul; Lie, Denny

    2017-11-01

    Recent studies have shown a correlation between scapular geometry and the development of atraumatic rotator cuff tears. However, a paucity of literature is available on the effects of critical shoulder angle (CSA) and acromial index (AI) on functional outcomes after arthroscopic rotator cuff repair. Hypothesis/Purpose: The purpose was to investigate the influence of CSA and AI on 24-month functional outcomes after arthroscopic rotator cuff repair. The hypothesis was that a larger CSA or AI would result in poorer postoperative outcomes. Cohort study; Level of evidence, 3. The study included 147 patients who underwent arthroscopic double-row rotator cuff repair for radiologically documented full-thickness supraspinatus tears. An independent reviewer measured the CSA and AI on preoperative radiographs. These patients were prospectively enrolled and were evaluated preoperatively as well as at 3, 6, 12, and 24 months postoperatively. Functional outcome was assessed with the Constant Shoulder Score (CSS), Oxford Shoulder Score (OSS), and University of California at Los Angeles (UCLA) Shoulder Rating Scale. The patients were first divided based on CSA: (1) ≤35° (control CSA) and (2) >35° (increased CSA); and then based on AI: (1) ≤0.7 and (2) >0.7. The Student unpaired t test, Pearson chi-square test, and Pearson correlation were performed to examine the influence of CSA and AI on postoperative functional outcome scores. At 6 months of follow-up, the CSS, OSS, and UCLA Shoulder Rating Scale were 10 ± 1, 4 ± 2, and 3 ± 1 points poorer in the increased CSA group compared with the control CSA group ( P = .005, P = .030, and P = .035, respectively). These scores were not significantly different between both AI groups. By 24 months of follow-up, all outcome scores were comparable between both CSA groups as well as between both AI groups. No significant correlation was found between either CSA or AI when compared with CSS, OSS, or UCLA Shoulder Rating Scale at 24

  7. Investigation of flow behaviour of coal particles in a pilot-scale fluidized bed gasifier (FBG) using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Kamudu, M Vidya; Prakash, S G; Krishanamoorthy, S; Anandam, G; Rao, P Seshubabu; Ramani, N V S; Singh, Gursharan; Sonde, R R

    2009-09-01

    Knowledge of residence time distribution (RTD), mean residence time (MRT) and degree of axial mixing of solid phase is required for efficient operation of coal gasification process. Radiotracer technique was used to measure the RTD of coal particles in a pilot-scale fluidized bed gasifier (FBG). Two different radiotracers i.e. lanthanum-140 and gold-198 labeled coal particles (100 gm) were independently used as radiotracers. The radiotracer was instantaneously injected into the coal feed line and monitored at the ash extraction line at the bottom and gas outlet at the top of the gasifier using collimated scintillation detectors. The measured RTD data were treated and MRTs of coal/ash particles were determined. The treated data were simulated using tanks-in-series model. The simulation of RTD data indicated good degree of mixing with small fraction of the feed material bypassing/short-circuiting from the bottom of the gasifier. The results of the investigation were found useful for optimizing the design and operation of the FBG, and scale-up of the gasification process.

  8. Radiotracers for PETT: new developments and perspectives

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references

  9. Radiotracer design strategies for neurocardiology

    International Nuclear Information System (INIS)

    Wieland, D.M.; Hutchins, G.D.

    1991-01-01

    Nuclear cardiologists have expended an inordinate amount of effort studying the open-quotes plumbingclose quotes of the heart but very little effort on the open-quotes wiringclose quotes. L. Rossi declared in 1988, open-quotes today's desultory information about basic changes in the heart's innervation, if compared with current knowledge about diseases of cardiac muscle and vessels, is largely attributable to an aura of forbidding technical difficulty.close-quote During the past three years, radiotracers have been developed for use in studies of cardiac nerve function by positron emission tomography (PET). The first clinical PET studies in this area were reported in 1990. This chapter discusses the strategies that led to the tracers presently available and the possible nature of future neuronal markers

  10. Fan Stagger Angle for Dirt Rejection

    Science.gov (United States)

    Gallagher, Edward J. (Inventor); Rose, Becky E. (Inventor); Brilliant, Lisa I. (Inventor)

    2015-01-01

    A gas turbine engine includes a spool, a turbine coupled to drive the spool, a propulsor coupled to be rotated about an axis by the turbine through the spool, and a gear assembly coupled between the propulsor and the spool such that rotation of the turbine drives the propulsor at a different speed than the spool. The propulsor includes a hub and a row of propulsor blades that extend from the hub. Each of the propulsor blades has a span between a root at the hub and a tip, and a chord between a leading edge and a trailing edge. The chord forms a stagger angle alpha with the axis, and the stagger angle alpha is less than 15 deg. at a position along the propulsor blade that is within an inboard 20% of the span.

  11. Faulting at Mormon Point, Death Valley, California: A low-angle normal fault cut by high-angle faults

    Science.gov (United States)

    Keener, Charles; Serpa, Laura; Pavlis, Terry L.

    1993-04-01

    New geophysical and fault kinematic studies indicate that late Cenozoic basin development in the Mormon Point area of Death Valley, California, was accommodated by fault rotations. Three of six fault segments recognized at Mormon Point are now inactive and have been rotated to low dips during extension. The remaining three segments are now active and moderately to steeply dipping. From the geophysical data, one active segment appears to offset the low-angle faults in the subsurface of Death Valley.

  12. Knee Angle and Stride Length in Association with Ball Speed in Youth Baseball Pitchers

    Directory of Open Access Journals (Sweden)

    Bart van Trigt

    2018-05-01

    Full Text Available The purpose of this study was to determine whether stride length and knee angle of the leading leg at foot contact, at the instant of maximal external rotation of the shoulder, and at ball release are associated with ball speed in elite youth baseball pitchers. In this study, fifty-two elite youth baseball pitchers (mean age 15.2 SD (standard deviation 1.7 years pitched ten fastballs. Data were collected with three high-speed video cameras at a frequency of 240 Hz. Stride length and knee angle of the leading leg were calculated at foot contact, maximal external rotation, and ball release. The associations between these kinematic variables and ball speed were separately determined using generalized estimating equations. Stride length as percentage of body height and knee angle at foot contact were not significantly associated with ball speed. However, knee angles at maximal external rotation and ball release were significantly associated with ball speed. Ball speed increased by 0.45 m/s (1 mph with an increase in knee extension of 18 degrees at maximal external rotation and 19.5 degrees at ball release. In conclusion, more knee extension of the leading leg at maximal external rotation and ball release is associated with higher ball speeds in elite youth baseball pitchers.

  13. The structure of rotational discontinuities. [in solar wind

    Science.gov (United States)

    Neugebauer, M.

    1989-01-01

    This study examines the structures of a set of rotational discontinuities detected in the solar wind by the ISEE-3 spacecraft. It is found that the complexity of the structure increases as the angle theta between the propagation vector k and the magnetic field decreases. For rotational discontinuities that propagate at a large angle to the field with an ion (left-hand) sense of rotation, the magnetic hodograms tend to be flattened, in agreement with prior numerical simulations. When theta is large, angular 'overshoots' are often observed at one or both ends of the discontinuity. When the propagation is nearly parallel to the field (when theta is small), many different types of structure are seen, ranging from straight lines, to S-shaped curves, to complex, disorganized shapes.

  14. Texture orientation of glancing angle deposited copper nanowire arrays

    International Nuclear Information System (INIS)

    Alouach, H.; Mankey, G.J.

    2004-01-01

    Self-assembled copper nanowires were deposited on native oxide Si(100) substrates using glancing angle deposition with and without substrate rotation. Wire morphology, texture and crystallographic orientation are strongly dependent on the deposition parameters. A method for determining the preferred crystal orientation is described. This orientation is found to be different from what is expected from the geometric orientation of the wires. For wires deposited without substrate rotation, the face-centered-cubic (fcc)(111) crystal orientation, which corresponds to the close-packed, low surface energy (111) plane of copper, lies between the long axis of the wire and that normal to the substrate. X-ray diffraction data show that the wires exhibit bundling behavior perpendicular to the plane of incidence. For samples deposited with azimuthal rotation of the substrate, the fcc(111) directions in the wires are evenly distributed in a cone around the long axis of the wires, which point normal to the substrate. When the substrate is rotated during deposition at an angle of 75 deg., the wires exhibit a strong fcc(220) texture. These observations show that wires deposited with substrate rotation are highly textured and have random orientations in the plane of the substrate

  15. Study of technological parameters influence on homogeneity of rubber mixings by means of radiotracer methods

    International Nuclear Information System (INIS)

    Koczorowska, E.

    1995-01-01

    The radiotracer methods have been worked out for analysis of physico-chemical phenomena. The analysis were carried out for rubber mixings in technological conditions and played a deciding role for quality of manufacturing assortment. The 35 S and 65 Zn have been used as radiotracers. Analysis of different technological parameters influence on behaviour of soluble and polymerized sulfur, zinc compounds as well as other components of the rubber mixing enables to formulate the conclusions important for rubber industry and technology from view point of quality of manufacturing products

  16. The early use of radiotracers in chemistry

    International Nuclear Information System (INIS)

    Grabowski, K.F.M.

    1986-01-01

    This article describes the historical background to the use of radiotracers, pioneered by de Hevesy and Paneth before World War I. It traces their early use in ion and metal interchange in electrolysis, self-diffusion rates, early biochemical experiments on lead uptake in plants, phosphorus metabolism in rats, through to their wider use with the production of artificial radioisotopes after World War II. Photosynthesis experiments using carbon-11 and carbon-14 are described and their present-day widespread use in kinetics, metabolic pathway studies and therapeutics is discussed. (UK)

  17. Radiotracers for PETT: new developments and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1983-01-01

    Radiotracer development with positron emitters has its major focus on problems in the neurosciences. Progress is reviewed for high-level isotope production and labelled precurser synthesis with the medical cyclotron. The study of regional brain glucose metabolism represented the first extension of one of the methods of neurochemical autoradiography to humans and the study of brain protein synthesis and neurotransmitter receptors followed. In a more general sense, one PETT instrumentation will provide resolution in the 5 mm range is already emerging. Research status is reviewed. 103 references. (PSB)

  18. Rotation of the Sacrum During Bellyboard Pelvic Radiotherapy

    International Nuclear Information System (INIS)

    Kasabasic, Mladen; Faj, Dario; Ivkovic, Ana; Jurkovic, Slaven; Belaj, Nenad

    2010-01-01

    Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 deg., causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error.

  19. Application of analogue computers to radiotracer data processing

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1979-01-01

    Some applications of analogue computers for processing the flow-system radiotracer-investigation data are presented. Analysis of the impulse response shaped to obtain the frequency response of the system under consideration can be performed on the basis of an estimated transfer function. Furthermore, simulation of the system behaviour for other excitation functions is discussed. Simple approach is made for estimating the model parameters in situations where the input signal is not approximated by the unit impulse function. (author)

  20. Preparation of the Nanostructured Radioisotope Metallic Oxide by Neutron Irradiation for Use as Radiotracers

    Directory of Open Access Journals (Sweden)

    Sang-Ei Seo

    2017-10-01

    Full Text Available Metallic oxides manganese dioxide (MnO2, samarium oxide (Sm2O3, and dysprosium oxide (Dy2O3 with nanorod-like structures were synthesized by the hydrothermal synthesis method, respectively. Subsequently, the nanostructured radioisotopes MnO2 with Mn-56, Sm2O3 with Sm-153, and Dy2O3 with Dy-165 were prepared by neutron irradiation from the HANARO research reactor, respectively. The three different elements, Mn, Sm, and Dy, were selected as radiotracers because these elements can be easily gamma-activated from neutrons (activation limits: 1 picogram (Dy, 1–10 picogram (Mn, 10–100 picogram (Sm. Furthermore, the synthesized radioisotopes can be used as radiotracers in Prompt Gamma Neutron Activation Analysis as the rare earth metals Dy and Sm were not present in the Korean environment. The successful synthesis of the radioisotope metallic oxides was confirmed by Transmission Electron Microscopy (TEM, Energy Dispersive X-ray Spectrometry (EDS, X-ray Diffraction (XRD analysis, and gamma spectroscopy analysis. The synthesized nanostructured radioisotope metallic oxides may be used as radiotracers in scientific, environmental, engineering, and industrial fields.

  1. Mental rotation of faces in healthy aging and Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Cassandra A Adduri

    Full Text Available BACKGROUND: Previous research has shown that individuals with Alzheimer's disease (AD develop visuospatial difficulties that affect their ability to mentally rotate objects. Surprisingly, the existing literature has generally ignored the impact of this mental rotation deficit on the ability of AD patients to recognize faces from different angles. Instead, the devastating loss of the ability to recognize friends and family members in AD has primarily been attributed to memory loss and agnosia in later stages of the disorder. The impact of AD on areas of the brain important for mental rotation should not be overlooked by face processing investigations -- even in early stages of the disorder. METHODOLOGY/PRINCIPAL FINDINGS: This study investigated the sensitivity of face processing in AD, young controls and older non-neurological controls to two changes of the stimuli -- a rotation in depth and an inversion. The control groups showed a systematic effect of depth rotation, with errors increasing with the angle of rotation, and with inversion. The majority of the AD group was not impaired when faces were presented upright and no transformation in depth was required, and were most accurate when all faces were presented in frontal views, but accuracy was severely impaired with any rotation or inversion. CONCLUSIONS/SIGNIFICANCE: These results suggest that with the onset of AD, mental rotation difficulties arise that affect the ability to recognize faces presented at different angles. The finding that a frontal view is "preferred" by these patients provides a valuable communication strategy for health care workers.

  2. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggests that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  3. A new uncertainty relation for angular momentum and angle

    International Nuclear Information System (INIS)

    Kranold, H.U.

    1984-01-01

    An uncertainty relation of the form ΔL 2 ΔSo >=sup(h/2π)/sub(2) is derived for angular momentum and angle. The non-linear operator So measures angles and has a simple interpretation. Subject to very general conditions of rotational invariance the above relation is unique. Radial momentum is not quantized

  4. Dose-on-demand production of diverse 18F-radiotracers for preclinical applications using a continuous flow microfluidic system.

    Science.gov (United States)

    Matesic, Lidia; Kallinen, Annukka; Greguric, Ivan; Pascali, Giancarlo

    2017-09-01

    The production of 18 F-radiotracers using continuous flow microfluidics is under-utilized due to perceived equipment limitations. We describe the dose-on-demand principle, whereby the back-to-back production of multiple, diverse 18 F-radiotracers can be prepared on the same day, on the same microfluidic system using the same batch of [ 18 F]fluoride, the same microreactor, the same HPLC column and SPE cartridge to obtain a useful production yield. [ 18 F]MEL050, [ 18 F]Fallypride and [ 18 F]PBR111 were radiolabeled with [ 18 F]fluoride using the Advion NanoTek Microfluidic Synthesis System. The outlet of the microreactor was connected to an automated HPLC injector and following the collection of the product, SPE reformulation produced the 18 F-radiotracer in productions for [ 18 F]MEL050 and [ 18 F]Fallypride were performed at total flow rates of 20μL/min, resulting in 40±13% and 25±13% RCY respectively. [ 18 F]PBR111 was performed at 200μL/min to obtain 27±8% RCY. Molar activities for each 18 F-radiotracer were >100GBq/μmol and radiochemical purities were >97%, implying that the cleaning procedure was effective. Using the same initial solution of [ 18 F]fluoride, microreactor, HPLC column and SPE cartridge, three diverse 18 F-radiotracers could be produced in yields sufficient for preclinical studies in a back-to-back fashion using a microfluidic system with no detectable cross-contamination. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  5. Radiotracer studies of fungicide residues in food plants

    International Nuclear Information System (INIS)

    1990-04-01

    Agricultural fungicides are chemicals used on seeds, crops and in soils throughout the growing season. Fungicide treatments may lead to various levels of chemical residues in food commodities. Primary emphasis has been placed on ethylenebisdithiocarbamates (EBDCs), an important group of agrofungicides used in preparations for spraying or dusting major crops such as apples, pears, broccoli, cabbages, egg plants, cauliflower, grapes, lettuce, peppers, celery, cucumbers and tomatoes. Treatments with EBDCs result in terminal residues containing ethylenthiourea (ETU). This is a toxicologically significant decomposition product which has attracted considerable attention in recent years due to indications of its potential goitrogenic and carcinogenic properties. In recognition of the need for a coordinated examination of ETU levels in food, particularly under tropical conditions, the program of radiotracer techniques as a tool for studying fungicide residue problems on food was initiated in 1984. In current studies, three EBDCs, maneb, zineb and mancozeb from different manufacturers in different countries were analysed. This report describes the model protocols (Annexes I, II and III) as they were set up for determination of residues in commodities and soil, using radiotracer and conventional chromatographic techniques . In the 16 papers presented in this report C 14 -labelled EBDCs are determined in plants, vegetables, and soils, before and after cooking, as a function of time and of other agricultural parameters. Refs, figs and tabs

  6. Observation of rotating nuclear molecules and determination of their lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    Comas, V.; Heinz, S.; Ackermann, D.; Heredia, J.; Hessberger, F.P.; Khuyagbaatar, J.; Kindler, B.; Lommel, B.; Mann, R. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Hofmann, S. [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Goethe-Universitaet Frankfurt, Institut fuer Physik, Frankfurt (Germany)

    2012-12-15

    Long-living rotating nuclear molecules (or ''dinuclear systems'') have been observed at the velocity filter SHIP at GSI in reactions of {sup 64}Ni + {sup 207}Pb at Coulomb barrier energies. The rotation was directly revealed by the velocity spectra of deep inelastic target-like transfer products which are formed during the lifetime of the nuclear molecule and emitted after its breakup. The corresponding rotation angles were about 180 degree pointing to long nuclear interaction times or lifetimes of the system, respectively. We deduced the lifetimes from the lines in the velocity spectra originating from two different rotation angles. Further, the unambiguous correlation of a certain transfer product with its individual velocity spectrum allowed us to study the lifetimes as a function of the number of transferred protons. (orig.)

  7. Research of working pulsation in closed angle based on rotating-sleeve distributing-flow system

    Science.gov (United States)

    Zhang, Yanjun; Zhang, Hongxin; Zhao, Qinghai; Jiang, Xiaotian; Cheng, Qianchang

    2017-08-01

    In order to reduce negative effects including hydraulic impact, noise and mechanical vibration, compression and expansion of piston pump in closed volume are used to optimize the angle between valve port and chamber. In addition, the mathematical model about pressurization and depressurization in pump chamber are analyzed based on distributing-flow characteristic, and it is necessary to use simulation software Fluent to simulate the distributing-flow fluid model so as to select the most suitable closed angle. As a result, when compression angle is 3°, the angle is closest to theoretical analysis and has the minimum influence on flow and pump pressure characteristic. Meanwhile, cavitation phenomenon appears in pump chamber in different closed angle on different degrees. Besides the flow pulsation is increasingly smaller with increasing expansion angle. Thus when expansion angle is 2°, the angle is more suitable for distributing-flow system.

  8. Application of 140La and 24Na as intrinsic radiotracers for investigating catalyst dynamics in FCCUs.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Nair, A G C; Tomar, B S; Nathaniel, T N; Reddy, A V R; Singh, Gursharan

    2009-09-01

    Instrumental neutron activation analysis (INAA) of fluid catalytic cracking (FCC) catalyst samples was carried out with an objective to identify activable elements and evaluate its suitability for use as an intrinsic radiotracer for tracing catalyst itself in Fluid Catalytic Cracking Units (FCCUs) used in petroleum refining. Two catalyst samples obtained from two different refineries were analyzed. Twelve different elements were identified in each catalyst sample and their respective concentrations were determined. From the recorded gamma-ray spectra, it was found that lanthanum-140 ((140)La) and sodium-24 ((24)Na) were the predominantly present and suitable radionuclides that could be used as radiotracers for tracing catalyst in FCCUs. Lanthanum being present in much higher concentration forms the major component of the radiotracer after irradiation. Based on the results of INAA, appropriate quantities of the catalyst samples were irradiated with neutrons to produce the desired amount of activity of lanthanum-140 and sodium-24 to be used as radiotracers for tracing the catalyst itself in a pilot as well as an industrial-scale FCCU. The residence time distribution (RTD) of catalyst was measured and analyzed to determine mean residence time (MRT). The axial dispersion model (ADM) was used to simulate the measured RTD data and investigate the degree of axial mixing. The results of the experiments were used to improve the design of pilot-scale FCCU and optimize the performance of the industrial-scale FCCU.

  9. A Model of Polarisation Rotations in Blazars from Kink Instabilities in Relativistic Jets

    Directory of Open Access Journals (Sweden)

    Krzysztof Nalewajko

    2017-10-01

    Full Text Available This paper presents a simple model of polarisation rotation in optically thin relativistic jets of blazars. The model is based on the development of helical (kink mode of current-driven instability. A possible explanation is suggested for the observational connection between polarisation rotations and optical/gamma-ray flares in blazars, if the current-driven modes are triggered by secular increases of the total jet power. The importance of intrinsic depolarisation in limiting the amplitude of coherent polarisation rotations is demonstrated. The polarisation rotation amplitude is thus very sensitive to the viewing angle, which appears to be inconsistent with the observational estimates of viewing angles in blazars showing polarisation rotations. Overall, there are serious obstacles to explaining large-amplitude polarisation rotations in blazars in terms of current-driven kink modes.

  10. New Methodology For Use in Rotating Field Nuclear MagneticResonance

    Energy Technology Data Exchange (ETDEWEB)

    Jachmann, Rebecca C. [Univ. of California, Berkeley, CA (United States)

    2007-01-01

    High-resolution NMR spectra of samples with anisotropicbroadening are simplified to their isotropic spectra by fast rotation ofthe sample at the magic angle 54.7 circ. This dissertation concerns thedevelopment of novel Nuclear Magnetic Resonance (NMR) methodologies basedwhich would rotate the magnetic field instead of the sample, rotatingfield NMR. It provides an over of the NMR concepts, procedures, andexperiments needed to understand the methodologies that will be used forrotating field NMR. A simple two-dimensional shimming method based onharmonic corrector rings which can provide arbitrary multiple ordershimming corrections were developed for rotating field systems, but couldbe used in shimming other systems as well. Those results demonstrate, forexample, that quadrupolar order shimming improves the linewidth by up toan order of magnitude. An additional order of magnitude reduction is inprinciple achievable by utilizing this shimming method for z-gradientcorrection and higher order xy gradients. A specialized pulse sequencefor the rotating field NMR experiment is under development. The pulsesequence allows for spinning away from the magic angle and spinningslower than the anisotropic broadening. This pulse sequence is acombination of the projected magic angle spinning (p-MAS) and magic angleturning (MAT) pulse sequences. This will be useful to rotating field NMRbecause there are limits on how fast a field can be spun and spin at themagic angle is difficult. One of the goals of this project is forrotating field NMR to be used on biological systems. The p-MAS pulsesequence was successfully tested on bovine tissue samples which suggeststhat it will be a viable methodology to use in a rotating field set up. Aside experiment on steering magnetic particle by MRI gradients was alsocarried out. Some movement was seen in these experiment, but for totalcontrol over steering further experiments would need to bedone.

  11. New Methodology For Use in Rotating Field Nuclear MagneticResonance

    Energy Technology Data Exchange (ETDEWEB)

    Jachmann, Rebecca C. [Univ. of California, Berkeley, CA (United States)

    2007-05-18

    High-resolution NMR spectra of samples with anisotropicbroadening are simplified to their isotropic spectra by fast rotation ofthe sample at the magic angle 54.7 circ. This dissertation concerns thedevelopment of novel Nuclear Magnetic Resonance (NMR) methodologies basedwhich would rotate the magnetic field instead of the sample, rotatingfield NMR. It provides an over of the NMR concepts, procedures, andexperiments needed to understand the methodologies that will be used forrotating field NMR. A simple two-dimensional shimming method based onharmonic corrector rings which can provide arbitrary multiple ordershimming corrections were developed for rotating field systems, but couldbe used in shimming other systems as well. Those results demonstrate, forexample, that quadrupolar order shimming improves the linewidth by up toan order of magnitude. An additional order of magnitude reduction is inprinciple achievable by utilizing this shimming method for z-gradientcorrection and higher order xy gradients. A specialized pulse sequencefor the rotating field NMR experiment is under development. The pulsesequence allows for spinning away from the magic angle and spinningslower than the anisotropic broadening. This pulse sequence is acombination of the projected magic angle spinning (p-MAS) and magic angleturning (MAT) pulse sequences. This will be useful to rotating field NMRbecause there are limits on how fast a field can be spun and spin at themagic angle is difficult. One of the goals of this project is forrotating field NMR to be used on biological systems. The p-MAS pulsesequence was successfully tested on bovine tissue samples which suggeststhat it will be a viable methodology to use in a rotating field set up. Aside experiment on steering magnetic particle by MRI gradients was alsocarried out. Some movement was seen in these experiment, but for totalcontrol over steering further experiments would need to bedone.

  12. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer

    International Nuclear Information System (INIS)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W.M.M.; Wiegerinck, Peter H.G.; Pietzsch, Jens; Bergmann, Ralf

    2009-01-01

    The radiosynthesis of [N-methyl- 11 C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [ 11 C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23±5% (decay-corrected, based upon [ 11 C]CO 2 ) at a specific activity of 47±12 GBq/μmol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl- 11 C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl- 11 C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl- 11 C]Org 34850 may still represent a suitable candidate for imaging GRs in humans

  13. Radiosynthesis and radiopharmacological evaluation of [N-methyl-11C]Org 34850 as a glucocorticoid receptor (GR)-binding radiotracer.

    Science.gov (United States)

    Wuest, Frank; Kniess, Torsten; Henry, Brian; Peeters, Bernardus W M M; Wiegerinck, Peter H G; Pietzsch, Jens; Bergmann, Ralf

    2009-02-01

    The radiosynthesis of [N-methyl-(11)C]Org 34850 as a potential brain glucocorticoid receptor (GR)-binding radiotracer is described. The radiosynthesis was accomplished via N-methylation of the corresponding desmethyl precursor with [(11)C]methyl triflate in a remotely controlled synthesis module to give the desired compound in a radiochemical yield of 23+/-5% (decay-corrected, based upon [(11)C]CO(2)) at a specific activity of 47+/-12 GBq/micromol (n=15) at the end-of-synthesis (EOS). The radiochemical purity after semi-preparative HPLC purification exceeded 95%. The total synthesis time was 35-40 min after end-of-bombardment (EOB). The radiotracer is rapidly metabolized in rat plasma leading to the formation of two more hydrophilic metabolites as the major metabolites. Radiopharmacological evaluation involving biodistribution and small animal PET imaging in normal Wistar rats showed that the compound [N-methyl-(11)C]Org 34850 is not able to sufficiently penetrate the blood-brain barrier. Therefore, compound [N-methyl-(11)C]Org 34850 seems not to be a suitable PET radiotracer for imaging rat brain GRs. However, involvement of Pgp or species differences requires further clarification to establish whether the radiotracer [N-methyl-(11)C]Org 34850 may still represent a suitable candidate for imaging GRs in humans.

  14. The method of the gas-dynamic centrifugal compressor stage characteristics recalculation for variable rotor rotational speeds and the rotation angle of inlet guide vanes blades if the kinematic and dynamic similitude conditions are not met

    Science.gov (United States)

    Vanyashov, A. D.; Karabanova, V. V.

    2017-08-01

    A mathematical description of the method for obtaining gas-dynamic characteristics of a centrifugal compressor stage is proposed, taking into account the control action by varying the rotor speed and the angle of rotation of the guide vanes relative to the "basic" characteristic, if the kinematic and dynamic similitude conditions are not met. The formulas of the correction terms for the non-dimensional coefficients of specific work, consumption and efficiency are obtained. A comparative analysis of the calculated gas-dynamic characteristics of a high-pressure centrifugal stage with experimental data is performed.

  15. Propeller rotation noise due to torque and thrust

    Science.gov (United States)

    Deming, Arthur F

    1940-01-01

    Sound pressure of the first four harmonics of rotation from a full-scale two-blade propeller were measured and are compared with values calculated from theory. The comparison is made (1) for the space distribution with constant tip speed and (2) for fixed space angles with variable tip speed. A relation for rotation noise from an element of radius developed by Gutin is given showing the effect of number of blades on the rotation noise.

  16. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    International Nuclear Information System (INIS)

    2008-01-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  17. Radiotracer and sealed source techniques for sediment management. Report of the consultants meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    Radioisotopes as tracers and sealed sources have been a useful and often irreplaceable tool for sediment transport studies. Gamma scattering and transmission gauges are used for sediment monitoring. Computational fluid dynamics (CFD) modelling is now an essential tool for the management of the natural systems and are increasingly used to study the fate and behaviour of particulates and contaminants. Radiotracer techniques are often employed to validate CFD models to enhance confidence in the predictive value of the models. Experimental tracing and numerical modelling are complementary methods of studying complex systems. During the last few decades, many radiotracer studies for the investigation of sediment transport in natural systems have been conducted worldwide, and various techniques for tracing and monitoring sediment have been developed by individual tracer groups. However, the developed techniques and methods for sediment tracing have not been compiled yet as a technical document, which is essential for the preservation of the knowledge and transfer of the technology to developing countries. Standard procedures or guidelines for the tracer experiments, which are vital for the reliability of the experiments and the acceptance of end-users, have not been established by the international tracer community either. The use of radiotracers in sediment transport studies demands the additional attention of the community to further develop these techniques and to ensure their transfer to developing countries. The Consultants' Meeting on 'Radiotracer and sealed source techniques for sediment management' was convened at the headquarters of the International Atomic Energy Agency (IAEA) in Vienna, Austria, from 21 to 25 April 2008. Experts from Argentina, Brazil, France, India, Republic of Korea and United Kingdom have been invited to discuss the current status of the tracer and nucleonic gauge technologies as applied for sediment transport investigations and to evaluate

  18. The Comparison of Mental Rotation Performance in Team and Individual Sports of Students

    Directory of Open Access Journals (Sweden)

    Fatemeh Pasand

    2015-01-01

    Full Text Available As a practical and causal-comparative study, the present study was aimed at comparing the mental rotation performance in team and individual sports among students. The statistical population included all of the female and male athletes (N=1500 from different districts of Shiraz, Iran who participated in the sport clubs. The participants of this study included 240 students between 12-14 years old (120 girls and 120 boys who were selected randomly from four sport fields (Volleyball, Basketball, Karate, and Gymnastics. Finally, 30 athletes were selected from each field. The Mentrat Program, a kind of software for the Mental Rotation Test was used as an evaluation tool. Analyses of variance (ANOVA with repeated measures were conducted to analysis of data. The results indicated that the impact of the rotational angle was significant in both team and individual groups (p0.05. It was also observed that there was a significant difference between the mental rotation scores of the males in the individual groups contrary to the ones in the team groups (p<0.05. As a whole, it seems that as the rotational angle increases, the ability of the mental rotation in the individual fields of sport (males will be higher compared to the team groups. Keywords: Mental Rotation, Rotational Angle, Team and Individual Sports, Students

  19. Rapid fluctuations in ionospheric Faraday rotation angle and 4GHz amplitude scintillation observed at Suva, Fiji

    International Nuclear Information System (INIS)

    Buonsanto, M.J.; Northcott, R.L.; Wright, R.W.H.

    1987-01-01

    Observations are reported of rapid fluctuations in Faraday rotation angle (FRA) recorded at 137MHz and amplitude scintillation at 4 GHz. The observations were made at Suva, Fiji Islands (average ionospheric coordinates 17 0 S, 178 0 E) and cover the period September, 1978 through March, 1983. Monthly occurrence of both the FRA fluctuations and the amplitude scintillation are positively correlated with sunspot number and negatively correlated with Ap and hmF2 at Tahiti. No events were seen in the summer months (November, December, and January) and it is suggested that the south to north neutral wind may be responsible for this. Maximum occurrence of both the 137 MHz FRA fluctuations and the 4 GHz scintillation is in April-May and August-September. The more rapid FRA fluctuations, termed here V-type, occur more often in months when the ambient electron density is larger. Most events occur in the pre-midnight sector, as observed elsewhere. Fewer 4 GHz events are observed at later times in the evening, as compared to the 137 MHz FRA fluctuations

  20. Growth and properties of the CuInS2 thin films produced by glancing angle deposition

    International Nuclear Information System (INIS)

    Akkari, F. Chaffar; Kanzari, M.; Rezig, B.

    2008-01-01

    We use the glancing angle deposition technique (GLAD) to grow CuInS 2 thin films by a vacuum thermal method onto glass substrates. During deposition, the substrate temperature was maintained at 200 deg. C. Due to shadowing effect the oblique angle deposition technique can produce nanorods tilted toward the incident deposition flux. The evaporated atoms arrive at the growing interface at a fixed angle θ measured from the substrate normal. The substrate is rotated with rotational speed ω fixed at 0.033 rev s -1 . We show that the use of this growth technique leads to an improvement in the optical properties of the films. Indeed high absorption coefficients (10 5 -3.10 5 cm -1 ) in the visible range and near-IR spectral range are reached. In the case of the absence of the substrate rotation, scanning electron microscopy pictures show that the structure of the resulting film consists of nanocolumns that are progressively inclined towards the evaporation source as the incident angle was increased. If a rapid azimuthal rotation accompanies the substrate tilt, the resulting nanostructure is composed of an array of pillars normal to the substrate. The surface morphology show an improvement without presence of secondary phases for higher incident angles (θ > 60 deg.)

  1. State-to-state differential cross sections for rotationally inelastic scattering of Na2 by He

    International Nuclear Information System (INIS)

    Bergmann, K.; Hefter, U.; Witt, J.

    1980-01-01

    State-to-state differential cross sections for rotational transitions of Na 2 in collisions with He are measured in the electronic and vibrational ground state at thermal collision energies using a new laser technique. Single rotational levels j/sub i/ are labelled by modulation of their population via laser optical pumping using a dye laser. The modulation of the fluorescence induced by an Ar + laser tuned to the level j/sub f/=28 is proportional to the cross section for collisional transfer j/sub i/→j/sub f/ and is detected at the scattering angle theta. A single optical fiber and a fiber bundle provide a flexible connection between the detector and the laser and photomultiplier, respectively. Transitions as large as Δj=20 are observed. At small angles elastic scattering is dominant, but rotationally inelastic processes become increasingly important at larger scattering angles. Rotational rainbow structure causing a steep onset of the cross section with the scattering angle theta (at fixed Δj) or a sharp cutoff with Δj (at fixed theta) is found. Preliminary results on rotational energy transfer in v=1 indicates that vibrational motion of the molecule favors larger rotational quantum jumps. semiclassical picture for the scattering of a hard ellipsoid gives a

  2. Effects of the Tongue-in-Groove Maneuver on Nasal Tip Rotation.

    Science.gov (United States)

    Antunes, Marcelo B; Quatela, Vito C

    2018-03-27

    Changes in nasal tip rotation is a very common maneuver performed during rhinoplasty. Among the many techniques used to achieve this goal is the tongue-in-groove (TIG). This study addresses the long-term effect of the TIG on the nasal tip rotation 1 year after rhinoplasty. The authors prospectively identified patients who were submitted to a rhinoplasty with a TIG maneuver over a period of 1 year. The angle of rotation was measured along the nostril axis angle. The data was analyzed using the t-test and a linear regression model. Seventeen patients were included. The average preoperative tip rotation was 93.95° (SD, 3.12°). Immediate postoperative tip rotation averaged 114.47° (SD, 3.79°). At the 1-year follow-up appointment, the tip rotation averaged 106.55° (SD, 3.54°). There was a significant loss of rotation at the 1-year postoperative visit (pTIG is a more dependable technique than the ones that rely on healing and contraction to obtain rotation. Our data demonstrated a significant loss of rotation during the first year. This suggests that the surgeon needs to slightly overcorrect the tip rotation to account for this loss.

  3. Unified parametrization for quark and lepton mixing angles

    International Nuclear Information System (INIS)

    Rodejohann, Werner

    2009-01-01

    We propose a new parametrization for the quark and lepton mixing matrices: the two 12-mixing angles (the Cabibbo angle and the angle responsible for solar neutrino oscillations) are at zeroth order π/12 and π/5, respectively. The resulting 12-elements in the CKM and PMNS matrices, V us and U e2 , are in this order irrational but simple algebraic numbers. We note that the cosine of π/5 is the golden ratio divided by two. The difference between π/5 and the observed best-fit value of solar neutrino mixing is of the same order as the difference between the observed value and the one for tri-bimaximal mixing. In order to reproduce the central values of current fits, corrections to the zeroth order expressions are necessary. They are small and of the same order and sign for quarks and leptons. We parametrize the perturbations to the CKM and PMNS matrices in a 'triminimal' way, i.e., with three small rotations in an order corresponding to the order of the rotations in the PDG-description of mixing matrices

  4. A rotated transmission grating spectrometer for detecting spectral separation of doublet Na

    Energy Technology Data Exchange (ETDEWEB)

    Santosa, Ignatius Edi [Department of Physics Education, Sanata Dharma University, Paingan Maguwohardjo Depok Sleman, Yogyakarta 55281, Indonesia edi@usd.ac.id (Indonesia)

    2015-04-16

    Transmission gratings are usually used in a spectrometer for measuring the wavelength of light. In the common design, the position of the grating is perpendicular to the incident light. In order to increase the angular dispersion, in contrary to the common design, in this experiment the transmission grating was rotated. Due to the non-zero incident angle, the diffracted light was shifted. This rotated transmission grating spectrometer has been used to determine the separation of doublet Na. In this experiment, the diffraction angle was measured at various incident angles. The spectral separation of doublet Na was identified from the difference in the diffraction angle of two spectral lines. This spectral separation depends on the incident angle, the grating constant and the order of diffraction. As the effect of increasing the incident angle, a significant increase of the spectral separation can be achieved up to three fold.

  5. A rotated transmission grating spectrometer for detecting spectral separation of doublet Na

    International Nuclear Information System (INIS)

    Santosa, Ignatius Edi

    2015-01-01

    Transmission gratings are usually used in a spectrometer for measuring the wavelength of light. In the common design, the position of the grating is perpendicular to the incident light. In order to increase the angular dispersion, in contrary to the common design, in this experiment the transmission grating was rotated. Due to the non-zero incident angle, the diffracted light was shifted. This rotated transmission grating spectrometer has been used to determine the separation of doublet Na. In this experiment, the diffraction angle was measured at various incident angles. The spectral separation of doublet Na was identified from the difference in the diffraction angle of two spectral lines. This spectral separation depends on the incident angle, the grating constant and the order of diffraction. As the effect of increasing the incident angle, a significant increase of the spectral separation can be achieved up to three fold

  6. Fabrication of a Large-Area Superhydrophobic SiO2 Nanorod Structured Surface Using Glancing Angle Deposition

    Directory of Open Access Journals (Sweden)

    Xun Lu

    2017-01-01

    Full Text Available A glancing angle deposition (GLAD technique was used to generate SiO2 nanorods on a glass substrate to fabricate a low-cost superhydrophobic functional nanostructured surface. GLAD-deposited SiO2 nanorod structures were fabricated using various deposition rates, substrate rotating speeds, oblique angles, and deposition times to analyze the effects of processing conditions on the characteristics of the fabricated functional nanostructures. The wettability of the surface was measured after surface modification with a self-assembled monolayer (SAM. The measured water contact angles were primarily affected by substrate rotation speed and oblique angle because the surface fraction of the GLAD nanostructure was mainly affected by these parameters. A maximum contact angle of 157° was obtained from the GLAD sample fabricated at a rotation speed of 5 rpm and an oblique angle of 87°. Although the deposition thickness (height of the nanorods was not a dominant factor for determining the wettability, we selected a deposition thickness of 260 nm as the optimum processing condition based on the measured optical transmittance of the samples because optically transparent films can serve as superhydrophobic functional nanostructures for optical applications.

  7. Application of radiotracers in an exotic field of botany. How to feed carnivorous plants

    International Nuclear Information System (INIS)

    Steinhauser, G.; Musilek, A.; Sterba, J.H.; Bichler, M.; Adlassnig, W.; Peroutka, M.; Lichtscheidl, I.K.

    2007-01-01

    In this paper, methods for the application of radiotracers in the Cobra Lily (Darlingtonia californica), a carnivorous pitcher plant, are described. The uptake of radiotracers such as 42 K and 54 Mn into the pitcher trap in aqueous solution could be proven, whereas uptake of 59 Fe ions could not be observed. No-carrier-added 54 Mn was taken up by the plants, regardless of extremely low concentrations. In contrast to earlier experiments using 14 C and 15 N-based tracers, the methodology presented allows quick, simple and reliable quantification of the nutrient uptake. The results of our experiments lead to a deeper biological understanding concerning the trace element household of this carnivorous plant and the absorption of micro- and macronutrients from trapped prey. (author)

  8. Radiotracer applications in industry - A guidebook

    International Nuclear Information System (INIS)

    2004-01-01

    The objective of this guidebook is to provide the radiotracer practitioner with practical, experience based information about all the facets of an investigation: design, planning, implementation, data treatment and interpretation of results. It is aimed at clearly identifying the questions that need to be asked at each stage of the investigation and, as comprehensively as possible, to either provide the answers to those questions or identify appropriate works of reference. The primary focus is on the methodology of radio tracing. Discussed aspects of the methodology are: tracer selection and optimization, methods of tracer injection, detection and measurement of radiation, data treatment and filtering including identification of available software, data analysis, interpretation and modelling. An early consideration in designing an investigation is selection of the tracer. The criteria of critical importance are that (1) the tracer must be compatible with the stream to be traced and (2) its behaviour must be representative of that stream. The first decision to make is whether to use a radioactive tracer or some alternative type. Generally, if the objectives of the investigation can be achieved using a non-radioactive tracer and without incurring disproportionate costs, then that tracer should be used. However, as will become apparent from the case studies presented, there are many problems that can be investigated only by using a radiotracer. In these cases it is necessary to choose a tracer based on the following selection criteria: type of radiation emitted: alpha particle, beta particle or gamma ray, half-life of the radionuclide, energy of the emitted radiation and optimization of the activity injected. The methodology reviewed considers the most commonly used radioisotopes for tracing solid materials, aqueous solutions, organic liquids and gaseous phases. The main emphasis is on the practical aspects of the technology. Various types of injection system are

  9. Mathematical Minute: Rotating a Function Graph

    Science.gov (United States)

    Bravo, Daniel; Fera, Joseph

    2013-01-01

    Using calculus only, we find the angles you can rotate the graph of a differentiable function about the origin and still obtain a function graph. We then apply the solution to odd and even degree polynomials.

  10. Radiotracer study on the efficiency of a cylindrical 2-stage anaerobic sludge digester

    International Nuclear Information System (INIS)

    Sung-Hee Jung; Joon-Ha Jin; Jong-Bum Kim

    2004-01-01

    Radiotracer experiments were carried out on a cylindrical 2-stage anaerobic sludge digester in order to investigate the improvement of their efficiency by means of RTD (residence time distribution) measurements before and after cleaning up the inside of the digester. The tracer was scandium in an EDTA solution which forms such a stable complex compound to keep the isotope form being adsorbed onto the surface of the pipelines or the wall. It was injected into the digester by pressurized nitrogen gas and its movement was monitored by NaI(Tl) scintillation detectors installed around the digester and recorded for a month by a 24-channel data acquisition system specially developed for radiotracer experiments by the Korea Tracer Group of KAERI. The experimental data was analysed for the MRT (mean residence time) and other parameters characterizing the flow behaviour. (author)

  11. Spectrum analysis of radiotracer residence time distribution for industrial and environmental applications

    International Nuclear Information System (INIS)

    Kasban, H.; Ashraf Hamid

    2014-01-01

    Radiotracer signal analysis and recognition still represents challenges in industrial and environmental applications specially in residence time distribution (RTD) measurement. This paper presents a development for the RTD signal recognition method that is based on power density spectrum (PDS). In this development, the features are extracted from the signals and/or from their higher-orders statistics (HOS) (Bispectrum and Trispectrum) instead of PDS. The HOS are estimated using direct, indirect and parametric estimations. The recognition results are analyzed and compared for different HOS estimation in order to select the best HOS estimation method for the purpose of RTD signal recognition. The artificial neural networks are used for training and testing of the proposed method. The proposed method is tested using RTD signals obtained from the measurements carried out using radiotracer technique. The simulation results show that the parametric estimation of the Trispectrum gives the higher recognition rate and is the most reliable for the RTD signal recognition. (author)

  12. The applicability of radiotracers for the investigation of the distillation of hydrocarbons

    International Nuclear Information System (INIS)

    Graczyk, J.; Iller, E.

    1976-01-01

    The use of radioactive tracers provide valuable methods for the investigation of distillation processes and have been applied to determine the characteristics of material streams, the dynamics of flowing phases and the composition in various parts of the distillation equipment. A method is proposed for testing individual radiotracers emplozemployed for the investigation of the distillation of hydrocarbons. The method consists in laboratory-scale distillation of a tracer together with a multicomponent hydrocarbon mixture, namely a gasoline fraction. The purification efficiency, distillation characteristics, and effective radiochemical purity of several tracers (reactor activated bromobenzene and synthesized C 3 H 7 82 Br, C 4 H 9 82 Br, C 5 H 11 82 Br) have been investigated. The distillation characteristics of bromohydrocarbons labelled with 82 Br and selected hydrocarbons tagged with 14 C (benzene and cumene) have been compared. The radiotracers investigated were employed for the determination of the hydrodynamic parameters of hydrocarbon distillation in laboratory packed columns and a commercial distillation tower. (author)

  13. Apparatus and method for variable angle slant hole collimator

    Science.gov (United States)

    Lee, Seung Joon; Kross, Brian J.; McKisson, John E.

    2017-07-18

    A variable angle slant hole (VASH) collimator for providing collimation of high energy photons such as gamma rays during radiological imaging of humans. The VASH collimator includes a stack of multiple collimator leaves and a means of quickly aligning each leaf to provide various projection angles. Rather than rotate the detector around the subject, the VASH collimator enables the detector to remain stationary while the projection angle of the collimator is varied for tomographic acquisition. High collimator efficiency is achieved by maintaining the leaves in accurate alignment through the various projection angles. Individual leaves include unique angled cuts to maintain a precise target collimation angle. Matching wedge blocks driven by two actuators with twin-lead screws accurately position each leaf in the stack resulting in the precise target collimation angle. A computer interface with the actuators enables precise control of the projection angle of the collimator.

  14. Midplane Faraday Rotation: A densitometer for BPX

    International Nuclear Information System (INIS)

    Jobes, F.C.; Mansfield, D.K.

    1992-02-01

    The density in a high field, high density tokamak such as BPX can be determined by measuring the Faraday rotation of a 10.6 μm laser directed tangent to the toroidal field. If there is a horizontal array of such beams, then n e (R) can be readily obtained with a simple Abel version about the center line of the tokamak. For BPX operated at full field and density, the rotation angle would be quite large -- about 75 degrees per pass. A layout in which a single laser beam is fanned out in the horizontal midplane of the tokamak, with a set of retroreflectors on the far side of the vacuum vessel, would provide good spatial resolution, depending only upon the number of reflectors. With this proposed layout, only one window would be needed. Because the rotation angle is never more than 1 ''fringe,'' the data is always good, and it is also a continuous measurement in time. Faraday rotation is dependent only upon the plasma itself, and thus is not sensitive to vibration of the optical components. Simulations of the expected results show that BPX would be well served even at low densities by a Midplane Faraday Rotation densitometer of ∼64 channels. Both TFTR and PBX-M would be suitable test beds for the BPX system

  15. Visual and Haptic Mental Rotation

    Directory of Open Access Journals (Sweden)

    Satoshi Shioiri

    2011-10-01

    Full Text Available It is well known that visual information can be retained in several types of memory systems. Haptic information can also be retained in a memory because we can repeat a hand movement. There may be a common memory system for vision and action. On the one hand, it may be convenient to have a common system for acting with visual information. On the other hand, different modalities may have their own memory and use retained information without transforming specific to the modality. We compared memory properties of visual and haptic information. There is a phenomenon known as mental rotation, which is possibly unique to visual representation. The mental rotation is a phenomenon where reaction time increases with the angle of visual target (eg,, a letter to identify. The phenomenon is explained by the difference in time to rotate the representation of the target in the visual sytem. In this study, we compared the effect of stimulus angle on visual and haptic shape identification (two-line shapes were used. We found that a typical effect of mental rotation for the visual stimulus. However, no such effect was found for the haptic stimulus. This difference cannot be explained by the modality differences in response because similar difference was found even when haptical response was used for visual representation and visual response was used for haptic representation. These results indicate that there are independent systems for visual and haptic representations.

  16. Discrete magic angle turning system, apparatus, and process for in situ magnetic resonance spectroscopy and imaging

    Science.gov (United States)

    Hu, Jian Zhi [Richland, WA; Sears, Jr., Jesse A.; Hoyt, David W [Richland, WA; Wind, Robert A [Kennewick, WA

    2009-05-19

    Described are a "Discrete Magic Angle Turning" (DMAT) system, devices, and processes that combine advantages of both magic angle turning (MAT) and magic angle hopping (MAH) suitable, e.g., for in situ magnetic resonance spectroscopy and/or imaging. In an exemplary system, device, and process, samples are rotated in a clockwise direction followed by an anticlockwise direction of exactly the same amount. Rotation proceeds through an angle that is typically greater than about 240 degrees but less than or equal to about 360 degrees at constant speed for a time applicable to the evolution dimension. Back and forth rotation can be synchronized and repeated with a special radio frequency (RF) pulse sequence to produce an isotropic-anisotropic shift 2D correlation spectrum. The design permits tubes to be inserted into the sample container without introducing plumbing interferences, further allowing control over such conditions as temperature, pressure, flow conditions, and feed compositions, thus permitting true in-situ investigations to be carried out.

  17. Method for high resolution magnetic resonance analysis using magic angle technique

    Science.gov (United States)

    Wind, Robert A.; Hu, Jian Zhi

    2003-12-30

    A method of performing a magnetic resonance analysis of a biological object that includes placing the object in a main magnetic field (that has a static field direction) and in a radio frequency field; rotating the object at a frequency of less than about 100 Hz around an axis positioned at an angle of about 54.degree.44' relative to the main magnetic static field direction; pulsing the radio frequency to provide a sequence that includes a phase-corrected magic angle turning pulse segment; and collecting data generated by the pulsed radio frequency. The object may be reoriented about the magic angle axis between three predetermined positions that are related to each other by 120.degree.. The main magnetic field may be rotated mechanically or electronically. Methods for magnetic resonance imaging of the object are also described.

  18. Synchronization of coupled active rotators by common noise

    Science.gov (United States)

    Dolmatova, Anastasiya V.; Goldobin, Denis S.; Pikovsky, Arkady

    2017-12-01

    We study the effect of common noise on coupled active rotators. While such a noise always facilitates synchrony, coupling may be attractive (synchronizing) or repulsive (desynchronizing). We develop an analytical approach based on a transformation to approximate angle-action variables and averaging over fast rotations. For identical rotators, we describe a transition from full to partial synchrony at a critical value of repulsive coupling. For nonidentical rotators, the most nontrivial effect occurs at moderate repulsive coupling, where a juxtaposition of phase locking with frequency repulsion (anti-entrainment) is observed. We show that the frequency repulsion obeys a nontrivial power law.

  19. Rotation Period Determination for 5143 Heracles

    Science.gov (United States)

    Pilcher, Frederick; Briggs, John W.; Franco, Lorenzo; Inasaridze, Raguli Ya.; Krugly, Yurij N.; Molotiv, Igor E.; Klinglesmith, Daniel A., III; Pollock, Joe; Pravec, Petr

    2012-07-01

    The Earth crossing minor planet 5143 Heracles made in late 2011 its closest approach to Earth since discovery. A consortium of observers found a synodic rotation period near 2.706 hours and amplitude increasing from 0.08 ±0.02 magnitudes at phase angle 20 degrees to 0.18 ±0.03 magnitudes at phase angle 87 degrees, with 3 unequal maxima and minima per cycle. Magnitude parameters H = 14.10 ±0.04 and G = 0.08 ±0.02 are found, and the color index V-R = 0.42 ±0.07. For an asteroid of taxonomic class Q, a suggested albedo pv = 0.20 ±0.05 yields estimated diameter D = 4.5 ±0.7 km. Three possible binary events were recorded, but these are insufficient for binary detection to be secure. Retrograde rotation is suggested.

  20. In Vivo Metabolic Trapping Radiotracers for Imaging Monoamine Oxidase-A and –B Enzymatic Activity

    Science.gov (United States)

    Brooks, Allen F.; Shao, Xia; Quesada, Carole A.; Sherman, Phillip; Scott, Peter J.H.; Kilbourn, Michael R.

    2017-01-01

    The isozymes of monoamine oxidase (MAO-A and MAO-B) are important enzymes involved in the metabolism of numerous biogenic amines, including the neurotransmitters serotonin, dopamine and norepinephrine. Recently, changes in concentrations of MAO-B have been proposed as an in vivo marker of neuroinflammation associated with Alzheimer’s disease. Previous developments of in vivo radiotracers for imaging changes in MAO enzyme expression or activity have utilized the irreversible propargylamine-based suicide inhibitors, or high-affinity reversibly-binding inhibitors. As an alternative approach, we have investigated 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines as metabolic trapping agents for the monoamine oxidases. MAO-mediated oxidation and spontaneous hydrolysis yields 1-[11C]methyl-2,3-dihydro-4-pyridinone as a hydrophilic metabolite that is trapped within brain tissues. Radiotracers with phenyl, biphenyl and 7-coumarinyl ethers were evaluated using microPET imaging in rat and primate brain. No isozyme selectivity for radiotracer trapping was observed in the rat brain for any compound, but in the monkey brain the phenyl ether demonstrated MAO-A selectivity, and the coumarinyl ether showed MAO-B selectivity. These are lead compounds for further development of 1-[11C]methyl-4-aryloxy-1,2,3,6-tetrahydropyridines with optimized brain pharmacokinetics and isozyme selectivity. PMID:26393369

  1. Chemical fate of the nicotinic acetylcholinergic radiotracer [123I]5-IA-85380 in baboon brain and plasma

    International Nuclear Information System (INIS)

    Baldwin, Ronald M.; Zoghbi, Sami S.; Staley, Julie K.; Brenner, Eric; Al-Tikriti, Mohammed S.; Amici, Louis; Fujita, Masahiro; Innis, Robert B.; Tamagnan, Gilles

    2006-01-01

    The fate of the nicotinic acetylcholinergic receptor radiotracer [ 123 I]5-IA-85380 ([ 123 I]5-IA) was studied in baboon by analyzing the chemical composition of brain tissue and plasma after intravenous administration of the tracer. Acetonitrile denaturation and high-performance liquid chromatography (HPLC) analysis showed predominantly unchanged (91-98%) parent tracer in all brain tissues examined, compared to significant metabolism (23% parent) in the plasma at 90 min postinjection, and control tissue recovery of 95-98%. [ 123 I]5-IA was distributed to the thalamus with a standardized uptake value of 9.2 (0.04% dose/g) or a concentration 5.8 times higher than that of the cerebellum. The HPLC behavior of a synthesized sample of one hypothesized metabolite, 5-iodo-3-pyridinol (5-IP), was consistent with plasma radiometabolite fraction. Since only parent radiotracer compound was found in brain tissue, these results add confidence that information derived from single photon emission computed tomography images of 123 I activity in the brain after [ 123 I]5-IA administration can be interpreted as distribution of an intact radiotracer

  2. Rotation of the swing plane of Foucault's pendulum and Thomas spin precession: two sides of one coin

    International Nuclear Information System (INIS)

    Krivoruchenko, Mikhail I

    2009-01-01

    Using elementary geometric tools, we apply essentially the same methods to derive expressions for the rotation angle of the swing plane of Foucault's pendulum and the rotation angle of the spin of a relativistic particle moving in a circular orbit (the Thomas precession effect). (methodological notes)

  3. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    The seasonal variation in sulfate reduction and the dynamics of sulfur and iron geochemistry were studied throughout a year in sediment of Aarhus Bay, Denmark. A radiotracer method for measuring sulfate reduction rates was applied with incubation times down to 15 min and a depth resolution down...... to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  4. Application of centrifuge modelling and radiotracers to migration studies of buried toxic waste

    International Nuclear Information System (INIS)

    Villar, H.P.

    1995-01-01

    A new technique to study the migration of souble waste components in soils, based on the application of centrifugue modelling and of selected short-lived radiotracers, is presented. The technique is based on the acceleration of the migration proceses of a specific tracer in a soil model, with simple and well-established scaling laws being used to interpret the results. The use of radiotracers allows geat flexibility and the adoption of a wide range of concentrations. Demosntrations of the technique have been carried out with two elements of radically distinct behaviour: iodine noted for its mobility in soils, and thallium, which tends to be strongly sorbed. Two different soil types have been used. The results semed to confirm what is known about the behaviour of both elements, so that the feasibility of the technique for such studies has been concluded. (author). 7 refs, 4 figs, 1 tab

  5. Characterization of actinide targets by low solid-angle alpha particle counting

    CERN Document Server

    Denecke, B; Pauwels, J; Robouch, P; Gilliam, D M; Hodge, P; Hutchinson, J M R; Nico, J S

    1999-01-01

    Actinide samples were characterized in an interlaboratory comparison between IRMM and NIST, including alpha-particle counting at defined low solid angle and counting in a 2 pi proportional gas counter. For this comparison, nine sup 2 sup 3 sup 3 UF sub 4 samples with high uniformity in the layer thickness were prepared at IRMM by deposition under vacuum. Polished silicon wafers were used as source substrates, and these were rotated during the deposition using a planetary rotation system. The estimated uncertainties for the defined low solid-angle methods were about 0.1% at both NIST and IRMM. The agreement of reported alpha-particle emission rates in the energy range 2.5-5.09 MeV was better than or equal to 0.02% for the defined solid-angle methods. When comparing total alpha-particle emission rates over the larger energy range 0-9 MeV (which includes all emissions from the daughter nuclides and the impurities), the agreement of the defined solid-angle methods was better than or equal to 0.05%. The 2 pi propo...

  6. Recoil generated radiotracers in studies of molecular dynamics

    International Nuclear Information System (INIS)

    Spicer, L.D.

    1981-01-01

    This chapter summarizes many of the contributions that the recoil technique of generating excited radiotracer atoms in the presence of a thermal environment is making to the field of chemical dynamics. Specific topics discussed critically include characterization of the generation and behavior of excited molecules including fragmentation kinetics and energy transfer, measurement of thermal and hot kinetic parameters, and studies of reaction mechanisms and stereochemistry as a function of reaction energy. Distinctive features that provide unique approaches to dynamical problems are evaluated in detail and the complementarity with more conventional techniques is addressed. Prospects for future applications are also presented

  7. Machine-specific quality assurance procedure for stereotactic treatments with dynamic couch rotations.

    Science.gov (United States)

    Wilson, Byron; Gete, Ermias

    2017-12-01

    We present a method in which the treatment couch's accuracy is measured using the electronic portal imaging device (EPID) and a phantom of our own construction. Using this phantom, we were able to quantify the treatment couch walkout, and the rotation angle accuracy for both static and dynamic couch treatments. These measurements were used to provide an accurate measure of the treatment couch isocenter as well as to verify the couch rotation angle recorded in the trajectory log. The phantom was constructed using a polystyrene slab in which five ball bearings of 4 mm diameter are placed on the same plane at varying radii (0, 2.8, 4.4, 5.6, and 6.7 cm). The couch was rotated through its full extent (-90, 90 degrees) while MV images were acquired continuously. The couch rotational accuracy was calculated using a least squares minimization which fit the locations of the BBs to their expected locations relative to reference setup conditions. Using this approach, rotation angle and isocenter walkout was calculated in three dimensions. These measurements were used to quantify the accuracy of the couch as well as to validate the Varian TrueBeam trajectory logs. Additionally, a method for an EPID-based couch star-shot measurement was developed and compared with the traditional film-based method. The measured couch center of rotation consisted of a cloud of points clustered around the room isocenter within 0.7 mm distance. The trajectory log couch angle values agreed with those recorded in the DICOM header of the EPID images to the third significant digit and the couch rotation angles recorded in the trajectory log and DICOM header agreed with the calculated values to 0.08 degrees. Comparison of couch star-shot measurement developed in this study with film-based star-shot measurements gave an agreement to within 0.2 mm. We have developed a quality assurance method for the treatment couch which is simple, accurate, and enables the user to access a multitude of consistent data

  8. Measurements of Drag Coefficients and Rotation Rates of Free-Falling Helixes

    KAUST Repository

    Al-Omari, Abdulrhaman A.

    2016-01-01

    in water, glycerol and a mixture of 30% glycerol in water. That generated rotation due to helical angle in water. However, we observe the rotation disappear in glycerol. The movement of the solid helical shapes is imaged using a high-speed video camera

  9. A radiotracer method for the dynamic measurement of the in-process inventory of dissolved materials

    International Nuclear Information System (INIS)

    Iqbal, M.N.; Gardner, R.P.; Verghese, K.

    1990-01-01

    A radioactive tracer method and the associated mathematical models have been developed to determine the in-process inventory of zirconium in a pulse column from the counting rate data taken at the exits of the aqueous and organic phases after an impulse injection of the radiotracer at the aqueous-phase inlet. Model parameters were obtained by applying a nonlinear least-squares fitting of the models to the experimental data. The total inventory of zirconium present in the pulse column under different operating conditions was determined by calculating the average residence time of zirconium in the system using these model parameters. The results indicate that the radiotracer technique provides a viable means of on-line determination of solute mass holdup. (author)

  10. Rod rotation and differential rod contouring followed by direct vertebral rotation for treatment of adolescent idiopathic scoliosis: effect on thoracic and thoracolumbar or lumbar curves assessed with intraoperative computed tomography.

    Science.gov (United States)

    Seki, Shoji; Kawaguchi, Yoshiharu; Nakano, Masato; Makino, Hiroto; Mine, Hayato; Kimura, Tomoatsu

    2016-03-01

    Although direct vertebral rotation (DVR) is now used worldwide for the surgical treatment of adolescent idiopathic scoliosis (AIS), the benefit of DVR in reducing vertebral body rotation in these patients has not been determined. We investigated a possible additive effect of DVR on further reduction of vertebral body rotation in the axial plane following intraoperative rod rotation or differential rod contouring in patients undergoing surgical treatment for AIS. The study was a prospective computed tomography (CT) image analysis. We analyzed the results of the two intraoperative procedures in 30 consecutive patients undergoing surgery for AIS (Lenke type I or II: 15; Lenke type V: 15). The angle of reduction of vertebral body rotation taken by intraoperative CT scan was measured and analyzed. Pre- and postoperative responses to the Scoliosis Research Society 22 Questionnaire (SRS-22) were also analyzed. To analyze the reduction of vertebral body rotation with rod rotation or DVR, intraoperative cone-beam CT scans of the three apical vertebrae of the major curve of the scoliosis (90 vertebrae) were taken pre-rod rotation (baseline), post-rod rotation with differential rod contouring, and post-DVR in all patients. The angle of vertebral body rotation in these apical vertebrae was measured and analyzed for statistical significance. Additionally, differences between thoracic curve scoliosis (Lenke type I or II; 45 vertebrae) and thoracolumbar or lumbar curve scoliosis (Lenke type V; 45 vertebrae) were analyzed. Pre- and postoperative SRS-22 scores were evaluated in all patients. The mean (90 vertebrae) vertebral body rotation angles at baseline, post-rod rotation or differential rod contouring, and post-rod rotation or differential rod contouring or post-DVR were 17.3°, 11.1°, and 6.9°, respectively. The mean reduction in vertebral body rotation with the rod rotation technique was 6.8° for thoracic curves and 5.7° for thoracolumbar or lumbar curves (pself

  11. Rotational magnetization of anisotropic media: Lag angle, ellipticity and accommodation

    International Nuclear Information System (INIS)

    Kahler, G.R.; Della Torre, E.

    2006-01-01

    This paper discusses the change in the ellipticity of two-dimensional magnetization trajectories as the applied field rotates from the easy axis to the hard axis of a material. Furthermore, the impact that the reversible magnetization has on the ellipticity is discussed, including the relationship between the magnetization squareness and the reversible component of the magnetization

  12. Asteroid rotation. IV

    International Nuclear Information System (INIS)

    Harris, A.W.; Young, J.W.

    1983-01-01

    The results from the year 1979 of an ongoing program of asteroid photometry at Table Mountain Observatory are presented. The results for 53 asteroids are summarized in a table, showing the number, name, opposition date, taxonomic class, diameter, absolute magnitude, mean absolute magnitude at zero phase angle and values of the absolute magnitude and linear phase coefficient derived from it, the rotation period in hours, peak-to-peak amplitude of variation, difference between mean and maximum brightness, and reliability index. Another table presents data on aspect and comparison stars, including brightness and distance data. Reliable rotation periods are reported for 22 asteroids for which no previous values are known. For seven asteroids, periods are reported which are revisions of previously reported values

  13. An imaging method of wavefront coding system based on phase plate rotation

    Science.gov (United States)

    Yi, Rigui; Chen, Xi; Dong, Liquan; Liu, Ming; Zhao, Yuejin; Liu, Xiaohua

    2018-01-01

    Wave-front coding has a great prospect in extending the depth of the optical imaging system and reducing optical aberrations, but the image quality and noise performance are inevitably reduced. According to the theoretical analysis of the wave-front coding system and the phase function expression of the cubic phase plate, this paper analyzed and utilized the feature that the phase function expression would be invariant in the new coordinate system when the phase plate rotates at different angles around the z-axis, and we proposed a method based on the rotation of the phase plate and image fusion. First, let the phase plate rotated at a certain angle around the z-axis, the shape and distribution of the PSF obtained on the image surface remain unchanged, the rotation angle and direction are consistent with the rotation angle of the phase plate. Then, the middle blurred image is filtered by the point spread function of the rotation adjustment. Finally, the reconstruction images were fused by the method of the Laplacian pyramid image fusion and the Fourier transform spectrum fusion method, and the results were evaluated subjectively and objectively. In this paper, we used Matlab to simulate the images. By using the Laplacian pyramid image fusion method, the signal-to-noise ratio of the image is increased by 19% 27%, the clarity is increased by 11% 15% , and the average gradient is increased by 4% 9% . By using the Fourier transform spectrum fusion method, the signal-to-noise ratio of the image is increased by 14% 23%, the clarity is increased by 6% 11% , and the average gradient is improved by 2% 6%. The experimental results show that the image processing by the above method can improve the quality of the restored image, improving the image clarity, and can effectively preserve the image information.

  14. Employment of the technique of radiotracers for analysis of industrial filters

    International Nuclear Information System (INIS)

    Ramos, Vitor Santos; Crispim, Verginia Reis

    2007-01-01

    The main aim of this work is to develop a methodology to evaluate the characteristics of porous media in filter using the radio-tracing technique. To do this, an experimental prototype filter made up of an acrylic cylinder, vertically mounted and supported on the lower side by a controlled leaking valve was developed. Two filters (spheres of acrylic and silica crystals) were used to check the movement of the water through the porous media using 123 I in its MIBG (iodine-123-meta-iodo benzyl-guanidine) form. Further up the filter an instantaneous injection of the substance makes it possible to see the passage of radioactive clouds through the two scintillatory detectors NaI (2x2) ' ' positioned before and immediately after the cylinder with the filtering element (porous media). The are caused by the detectors on the passage of the radioactive cloud are analyzed through statistical functions using the weighted moment method which makes it possible to calculate the Residence-Time (the amount of time the tracer takes to thoroughly pass through the filter) per the equation of dispersion in tubular flow and the one-directional flow of the radiotracer in the porous media. (author)

  15. The coherent interlayer resistance of a single, rotated interface between two stacks of AB graphite

    Energy Technology Data Exchange (ETDEWEB)

    Habib, K. M. Masum, E-mail: khabib@ee.ucr.edu; Sylvia, Somaia S.; Neupane, Mahesh; Lake, Roger K., E-mail: rlake@ee.ucr.edu [Department of Electrical Engineering, University of California, Riverside, California 92521-0204 (United States); Ge, Supeng [Department of Physics and Astronomy, University of California, Riverside, California 92521-0204 (United States)

    2013-12-09

    The coherent, interlayer resistance of a misoriented, rotated interface between two stacks of AB graphite is determined for a variety of misorientation angles. The quantum-resistance of the ideal AB stack is on the order of 1 to 10 mΩ μm{sup 2}. For small rotation angles, the coherent interlayer resistance exponentially approaches the ideal quantum resistance at energies away from the charge neutrality point. Over a range of intermediate angles, the resistance increases exponentially with cell size for minimum size unit cells. Larger cell sizes, of similar angles, may not follow this trend. The energy dependence of the interlayer transmission is described.

  16. The coherent interlayer resistance of a single, rotated interface between two stacks of AB graphite

    International Nuclear Information System (INIS)

    Habib, K. M. Masum; Sylvia, Somaia S.; Neupane, Mahesh; Lake, Roger K.; Ge, Supeng

    2013-01-01

    The coherent, interlayer resistance of a misoriented, rotated interface between two stacks of AB graphite is determined for a variety of misorientation angles. The quantum-resistance of the ideal AB stack is on the order of 1 to 10 mΩ μm 2 . For small rotation angles, the coherent interlayer resistance exponentially approaches the ideal quantum resistance at energies away from the charge neutrality point. Over a range of intermediate angles, the resistance increases exponentially with cell size for minimum size unit cells. Larger cell sizes, of similar angles, may not follow this trend. The energy dependence of the interlayer transmission is described

  17. Determination of oil reservoir radiotracer (S14CN−) in a single step using a plastic scintillator extractive resin

    International Nuclear Information System (INIS)

    Bagán, H.; Tarancón, A.; Stavsetra, L.; Rauret, G.; García, J.F.

    2012-01-01

    Highlights: ► A new procedure for S 14 CN − radiotracer determination using PS resin was established. ► The minimum detectable activity for a 100 mL sample is 0.08 Bq L −1 . ► The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L −1 . ► PS resin is capable to quantify S 14 CN − radiotracer samples with errors lower than 5%. ► PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S 14 CN − . Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of 14 C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L −1 and 0.31 Bq L −1 , respectively. The established procedure was applied to active samples from oil reservoirs and errors lower than 5% in the sample

  18. Visualization and spectral synthesis of rotationally distorted stars

    International Nuclear Information System (INIS)

    Dall, T H; Sbordone, L

    2011-01-01

    Simple spherical, non-rotating stellar models are inadequate when describing real stars in the limit of very fast rotation: Both the observable spectrum and the geometrical shape of the star deviate strongly from simple models. We attempt to approach the problem of modeling geometrically distorted, rapidly rotating stars from a new angle: By constructing distorted geometrical models and integrating standard stellar models with varying temperature, gravity, and abundances, over the entire surface, we attempt a semi-empirical approach to modeling. Here we present our methodology, and present simple examples of applications.

  19. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of /sup 11/C, /sup 18/F and /sup 13/N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume.

  20. Synthesis of carbon-11, fluorine-18, and nitrogen-13 labeled radiotracers for biomedical applications

    International Nuclear Information System (INIS)

    Fowler, J.S.; Wolf, A.P.

    1981-01-01

    A number of reviews, many of them recent, have appeared on various aspects of 11 C, 18 F and 13 N-labeled radiotracers. This monograph treats the topic principally from the standpoint of synthetic organic chemistry while keeping in perspective the necessity of integrating the organic chemistry with the design and ultimate application of the radiotracer. Where possible, recent examples from the literature of organic synthesis are introduced to suggest potentially new routes which may be applied to problems in labeling organic molecules with the short-lived positron emitters, carbon-11, fluorine-18, and nitrogen-13. The literature survey of carbon-11, fluorine-18 and nitrogen-13 labeled compounds presented are of particular value to scientists working in this field. Two appendices are also included to provide supplementary general references. A subject index concludes this volume

  1. Flux expulsion and trapping in rotating discs of type II superconductors

    International Nuclear Information System (INIS)

    Boyer, R.; Leblanc, M.A.R.

    1977-01-01

    The magnetic flux rotating in step with a type II superconducting disc is measured with orthogonal pick up coils for various previous magnetic histories vs H 0 applied at right angles to the axis of rotation. For some initial magnetic states, flux expulsion, independent of the rate of rotation, occurs during the initial rotation. A simple model where flux lines leave the specimen against the magnetic pressure in the active region accounts for the observations. (author)

  2. Development of gold nanoparticle radiotracers for investigating multiphase system in process industries

    International Nuclear Information System (INIS)

    Mohd Amirul Syafiq Mohd Yunos; Jaafar Abdullah; Engku Fahmi Engku Chik; Noraishah Othman

    2010-01-01

    This paper describes the development of colloidal 197 Au-SiO 2 with core-shell structure nanoparticle radiotracers. Using conventional citrate-reduction method, gold nanoparticles were prepared from its corresponding metal salts in aqueous solution then coated with uniform shells of amorphous silica via a sol-gel reaction. This target material of radiotracer application used to investigate multiphase system in process industries without disturbing the system operation. The citrate-reduction-based method provides gold nanoparticles with higher concentration and narrow size distribution. By using transmission electron microscopy (TEM), the resultant of particle size and silica coatings could be varied from tens to several hundred of nanometers by controlling the catalyzer and precipitation time. 197 Au-SiO 2 core-shell nano structure is good to prevent the particles from getting conglomerate resulting in a big mass. In addition, silica surface offer very good chances that make the hydrophobicity behavior on the gold nanoparticles. EDXRF spectrum has proven that 197 Au-SiO 2 core-shell nanoparticles sample consists purely of a gold and silica particles. (author)

  3. Transfer matrix approach for the Kerr and Faraday rotation in layered nanostructures.

    Science.gov (United States)

    Széchenyi, Gábor; Vigh, Máté; Kormányos, Andor; Cserti, József

    2016-09-21

    To study the optical rotation of the polarization of light incident on multilayer systems consisting of atomically thin conductors and dielectric multilayers we present a general method based on transfer matrices. The transfer matrix of the atomically thin conducting layer is obtained using the Maxwell equations. We derive expressions for the Kerr (Faraday) rotation angle and for the ellipticity of the reflected (transmitted) light as a function of the incident angle and polarization of the light. The method is demonstrated by calculating the Kerr (Faraday) angle for bilayer graphene in the quantum anomalous Hall state placed on the top of dielectric multilayers. The optical conductivity of the bilayer graphene is calculated in the framework of a four-band model.

  4. The use of rare earth radiotracers in the study of solvent extraction kinetics

    International Nuclear Information System (INIS)

    Lim, T.M.; Tran, T.

    1993-01-01

    The suitability of rare earth radionuclides as tracers in research and industry are assessed. In general, the most desirable characteristics of radiotracers for process studies are a half-life in the range 5-200 days, a high yield, high energy γ-emission and low cost of production. The majority of rare earths have at least one radionuclide with acceptable characteristics. The application of radiotracers to the study of kinetics of rare earth solvent extraction have been studied using a modified Lewis cell. Terbium-160 was selected as the most suitable rare earth radionuclide for our experiments. Samples of both aqueous and organic phases were continuous withdrawn, monitored using an automated γ-counting system based on two sodium iodide detectors and then pumped back to the Lewis cell. Excellent results were obtained and the rate of extraction was shown to be first order with respect to the terbium concentration. 6 refs., 1 tab., 7 figs

  5. Characterization of electrochemical cell for production of radiotracer in organic medium

    International Nuclear Information System (INIS)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da; Coordenacao de Pos-Graduacao e Pesquisa de Engenharia

    2017-01-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  6. Characterization of electrochemical cell for production of radiotracer in organic medium

    Energy Technology Data Exchange (ETDEWEB)

    Kenup-Hernandes, Hericka O.; Brandão, Luís Eduardo B.; Silva, Ademir X. da, E-mail: hkenup@ien.gov.br, E-mail: brandao@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-11-01

    In a petrochemical plant, precise knowledge of the flow of the compounds that flow inside the pipelines that carry oil and these derivatives is crucial. To perform these controls a series of flow meters are installed inside ducts in direct contact with the fluid to be monitored. This invasive method presents a great limitation because the oil aggressive proprieties that require these measurement devices are subjected to frequent calibrations which, in turn, cause the stoppage of the plant and low productivity. In this sense, radiotracers has been used in conjunction with the time transient method, by configuring a precise and non-invasive measurement technique. This work presents the study of the characterization of an electrolytic cell model for the production of petroleum derivatives labeled with Iodine-123 for use as radiotracer in the measurement of flow in ducts and the time transient method. Labelling of organic compounds usually a sequence of solvent separation and extraction steps which, when used for labeling oil and oil derivatives it causes high gamma exposition for the operator at considerable dose rates due to the need for direct interaction with the marking system. The objective of this work is to develop a cell model that is part of a compact, automatically operated labelling system with physics and chemistry parameters defined to optimize the organic phase labelling processes of petroleum derivatives. The labelling cell is composed of a cylindrical reaction vessel where the aqueous medium containing the iodine-123 in the form of sodium iodide (NaI-I123) is inserted with about 2 mCi of activity and the organic medium. In the system are introduced, two Platinum electrodes where a voltage of 0. 8 V is applied. This system allows the production of radiotracer for a rapid pulse injection. The results show that there was no significant variation of the stability of the system in the temperature range of 25 °C to 40 °C and showed a labelling efficiency

  7. Effect of the degree of sternal depression on the cardiac rotation in pectus excavatum: evaluation with spiral CT

    International Nuclear Information System (INIS)

    Yu Jianqun; Yang Zhigang; Li Zhenlin; Guo Yingkun; Lu Chunyan; Zhang Mei

    2004-01-01

    Objective: To evaluate the effects of the degree of sternal depression on the cardiac rotation in pectus excavatum by using spiral CT. Methods: Spiral CT features of 32 patients with surgically corrected pectus excavatum were retrospectively reviewed. They included 27 males and 5 females ranging in age from 6 months to 17 years (mean, 6.3 years). Analysis was based on relationship among the degree of sternal depression, CT depression index, cardiac rotation angle, and PV angle. Results: 32 cases of pectus excavatum presented the sternal depression (21 ± 7) mm, CT depression index 2.9 ± 1.8, cardiac rotation angle (55.9 ± 9.8) degree, and PV angle (49.8 ± 14.0) degree, respectively. The sternal depression (17 mm) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (21 mm) and CT depression index larger than 2.9 (27 mm) (F 5.39, P<0.01). Cardiac rotation angle (49.7 degree) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (55.5 degree) and CT depression index larger than 2.9 (66.9 degree) (F=7.44, P<0.01). PV angle (58.7 degree) in cases with CT depression index less than 2.4 was larger than those with CT depression index 2.4-2.9 (46.5 degree) and CT depression index more than 2.9 (42.4 degree) ( F=3.33, P<0.05). Cardiac rotation angle of pectus excavatum had positive correlation with the CT depression index (γ=0.73, P<0.01). Conclusion: Spiral CT is a better tool for revealing chest deformity and corresponding cardiac rotation. The degree of sternal depression in pectus excavatum directly influences the cardiac rotation, and they had positive correlation. (authors)

  8. [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine receptors using single photon emission computer tomography; [{sup 123}I]-3-Iodcytisin als moeglicher Radiotracer fuer die Darstellung der nikotinergen Acetylcholin Rezeptoren mittels Single-Photon-Emissions-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Paulik, Dagmar Julia

    2015-03-06

    For the synthesis of [{sup 123}I]-3-Iodcytisin as possible radiotracer for the imaging of nicotinic acetylcholine (nACh) receptors using SPECT two different technologies were used: the radio-iodination with iodogen and the radio-iodination with nitric acid. The latter one showed higher efficiency. The radiotracer will allow to detect degenerative processes and other nACh-depending diseases in the brain (Alzheimer, Parkinson) and to observe the progress. The autoradiography is aimed to the imaging of the nACh receptors in the brain bypassing the brain-blood barrier. The highest activity was measured in the thalamus of mice and rat brains.

  9. Application of radiotracer technology to the study of coastal processes

    International Nuclear Information System (INIS)

    Airey, P.; Szymczak, R.; Zaw, M.; Tu, J.; Kluss, T.; Barry, J.

    1999-01-01

    Recent progress at ANSTO in the applications of radiotracer techniques to the study of coastal processes is reviewed. Tracers are used in detailed studies of specific components of complex environmental systems and are applied to the evaluation and extension of numerical models. Examples include studies of the aggregation of sewage particles following release from ocean outfalls. The use of tracers to study the impact of storm events on bedload transport at depth has also been demonstrated

  10. Study of regional pulmonary gas exchange using radiotracers

    International Nuclear Information System (INIS)

    Hichwa, R.D.

    1981-01-01

    Respiration involves the exchange of gases between the environment and the blood across the alveolar membrane. Four processes characterize the dynamics of gas exchange: ventilation, diffusion, perfusion and chemical binding with hemoglobin. A study was undertaken to investigate each of these processes, utilizing accelerator production and high yield synthesis of four gaseous radiotracers (/sup 81m/Kr, Ch 3 18 F, 11 CO, 15 O 2 ). Conventional gamma camera images and ancillary physiological data were acquired. Mathematical models were developed to predict the tracer clearance from the lungs during a breath hold and during washout post breath hold. Images of the insoluble /sup 81m/Kr synchronized with the tidal breathing maneuver depict regional ventilation. Tracer bolus inhalation, relative compliance and regional phase information are obtained from krypton dCynamic studies. More soluble CH 3 18 F is used to determine regional pulmonary perfusion during a breath hold. Respiratory clearance of seven, inert, positron-emitting radiotracers define the tracer volume of distribution. The tight-binding of 11 CO to hemoglobin permits the regional measurement of carbon monoxide pulmonary diffusion capacity. A relative CO blood:gas partition coefficient is calculated from the washout of no-carrier-added levels of 11 CO and verified by in vitro radiometric measurements. Regional oxygen pulmonary diffusion capacity determined from 15 O 2 clearance during a breath hold reveals results similar to those obtained with CO. All experimental data are in good agreement with the predictions of a two-compartment open model. A more advanced oxygen model is presented that incorporates radioactive oxygen exchange with stable oxygen on the hemoglobin molecule and metabolic removal of the tracer at the tissues

  11. Measurement of plasma conductivity using faraday rotation of submillimeter waves

    International Nuclear Information System (INIS)

    Kuzmenko, P.J.; Self, S.A.

    1983-01-01

    This paper examines the application of Faraday rotation to the measurement of electron combustion MHD plasmas. Details on the design of a working system are given, including the selection of operating wavelength. A theoretical comparison between the Faraday rotation technique and two-path interferometry shows Faraday rotation in its simplest form to be somewhat less sensitive to changes in electron concentration. This deficit can be balanced against greater immunity to vibration and thermal drift. Improved techniques of measuring the rotation angle promise greater sensitivity. A preliminary experiment has verified the technique

  12. Investigation of sediment transport and optimization of dredging operations in Indian ports using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.

    2012-01-01

    India has a long coastline of about 7,515 km and there are twelve major ports situated on the coastline. Out of them, six are situated on the West Coast whereas other six are situated on the East Coast. In addition to this, there are more than 140 minor ports and other marine establishments situated along the coastline. Each port and marine project has a navigation channel and depth of this navigation channel needs to be maintained to a level of at least 12-15 meters for smooth sailing of ships. Sediments continuously move along the coast due to alongshore currents generated by the waves and tides; and get deposited in navigation channels. For maintaining the required depth of the channels, the dredging operation is carried out. throughout the year or as and when required. Development of a new port or harbour also involves huge capital dredging. The dredged sediments generated during maintenance or capital dredging needs to be dumped at a suitable location, so that it does not find its way back to the channel and obstruct sailing of ships. Moreover the selected site should be such that the turn around time of the dredger is kept minimum to economize the dredging operation. In order to meet the above requirements, the knowledge of transport parameters such as the general direction of movement, extent of lateral and longitudinal movement, transport velocity, transport thickness and bed load movement rate is required. Radiotracer techniques are commonly used to investigate sediment transport on seabed and evaluate the suitability of the proposed dumping sites. Scandium-46 (half-life: 84 days, Gamma energies: 0.89 MeV (100%), 1.12 MeV (100%)) in the form of scandium glass powder is the most suitable radiotracer for tracing sediments on seabed. The activity used in an investigation ranges from 75-300 GBq (2-8 Ci). The suitably prepared particulate radiotracer is injected on seabed at the proposed site using a specially designed injection system and its movement is

  13. METHODOLOGICAL NOTES: Rotation of the swing plane of Foucault's pendulum and Thomas spin precession: two sides of one coin

    Science.gov (United States)

    Krivoruchenko, Mikhail I.

    2009-08-01

    Using elementary geometric tools, we apply essentially the same methods to derive expressions for the rotation angle of the swing plane of Foucault's pendulum and the rotation angle of the spin of a relativistic particle moving in a circular orbit (the Thomas precession effect).

  14. Propagation of rotational Risley-prism-array-based Gaussian beams in turbulent atmosphere

    Science.gov (United States)

    Chen, Feng; Ma, Haotong; Dong, Li; Ren, Ge; Qi, Bo; Tan, Yufeng

    2018-03-01

    Limited by the size and weight of prism and optical assembling, Rotational Risley-prism-array system is a simple but effective way to realize high power and superior beam quality of deflecting laser output. In this paper, the propagation of the rotational Risley-prism-array-based Gaussian beam array in atmospheric turbulence is studied in detail. An analytical expression for the average intensity distribution at the receiving plane is derived based on nonparaxial ray tracing method and extended Huygens-Fresnel principle. Power in the diffraction-limited bucket is chosen to evaluate beam quality. The effect of deviation angle, propagation distance and intensity of turbulence on beam quality is studied in detail by quantitative simulation. It reveals that with the propagation distance increasing, the intensity distribution gradually evolves from multiple-petal-like shape into the pattern that contains one main-lobe in the center with multiple side-lobes in weak turbulence. The beam quality of rotational Risley-prism-array-based Gaussian beam array with lower deviation angle is better than its counterpart with higher deviation angle when propagating in weak and medium turbulent (i.e. Cn2 beam quality of higher deviation angle arrays degrades faster as the intensity of turbulence gets stronger. In the case of propagating in strong turbulence, the long propagation distance (i.e. z > 10km ) and deviation angle have no influence on beam quality.

  15. Uniform analytic approximation of Wigner rotation matrices

    Science.gov (United States)

    Hoffmann, Scott E.

    2018-02-01

    We derive the leading asymptotic approximation, for low angle θ, of the Wigner rotation matrix elements, dm1m2 j(θ ) , uniform in j, m1, and m2. The result is in terms of a Bessel function of integer order. We numerically investigate the error for a variety of cases and find that the approximation can be useful over a significant range of angles. This approximation has application in the partial wave analysis of wavepacket scattering.

  16. Garnet film rotator applied in polarizing microscope for domain image modulation (abstract)

    Science.gov (United States)

    Wakabayashi, K.; Numata, T.; Inokuchi, S.

    1991-04-01

    A garnet film polarization rotator placed before the analyzer in a polarizing microscope was investigated to obtain the difference image of a positive and a negative one of magnetic domain in real time along with an image processor. In the difference image, a nonmagnetic image can be reduced and hence the weak magnetic contrast enhanced. Theoretical calculation of S/N and contrast C of the domain image as a function of the rotation shows they take maxima at the rotation angle of 2.6° and 0.1°, respectively, with the extinction ratio of e=4×10-6 of a polarizing microscope. Thus, since the thickness of the garnet film required is 1 μm or so, the absorption by the garnet rotator does not bring a serious problem even in a visible region for the domain observation. The optimum rotation of the rotator for a high quality observation was obtained by a quantitative study of images obtained experimentally as well as by a visual evaluation. A magnetically unsaturated garnet film with perpendicular magnetization (i.e., multidomain) was employed as a rotator, in which the polarization rotation angle θm of the undeflected beam with respect to the light diffraction could be continuously varied by an applied magnetic field. The dependences of S/N and C on θm were measured, resulting in a well agreement between the measured and the calculated. The visually best image was obtained at θm=0.5° which made the product of S/N and C maximum. The domain image of the Kerr rotation angle of θk=0.22° was observed in S/N=47 dB and C=0.4 when Ar+ laser (λ=515 nm) of tenths of a watt was employed as a light source. Since the domain image with 47 dB S/N does not need an image summation for a noise reduction, a garnet film rotator makes it possible to invert the contrast of a domain image in a real time for an improved domain observation.

  17. Non-reciprocity of Faraday rotation in gyrotropic crystals

    OpenAIRE

    Vlokh R.; Adamenko D.

    2008-01-01

    It is shown that, under the conditions of coexisting natural optical activity and non-zero linear optical birefringence, reversal of the light wave vector sign can result in changing angle of Faraday rotation.

  18. Analyzing the Influence of the Angles of Incidence and Rotation on MBU Events Induced by Low LET Heavy Ions in a 28-nm SRAM-Based FPGA

    Science.gov (United States)

    Tonfat, Jorge; Kastensmidt, Fernanda Lima; Artola, Laurent; Hubert, Guillaume; Medina, Nilberto H.; Added, Nemitala; Aguiar, Vitor A. P.; Aguirre, Fernando; Macchione, Eduardo L. A.; Silveira, Marcilei A. G.

    2017-08-01

    This paper shows the impact of low linear energy transfer heavy ions on the reliability of 28-nm Bulk static random access memory (RAM) cells from Artix-7 field-programmable gate array. Irradiation tests on the ground showed significant differences in the multiple bit upset cross section of configuration RAM and block RAM memory cells under various angles of incidence and rotation of the device. Experimental data are analyzed at transistor level by using the single-event effect prediction tool called multiscale single-event phenomenon prediction platform coupled with SPICE simulations.

  19. Recent VLA Measurements of CME-Induced Faraday Rotation

    Science.gov (United States)

    Kooi, Jason; Thomas, Najma; Guy, Michael; Spangler, Steven R.

    2018-01-01

    Observations of Faraday rotation, the change in polarization position angle of linearly polarized radiation as it propagates through a magnetized plasma, have been used for decades to determine the strength and structure of the coronal magnetic field and plasma density. Similarly, observations of Faraday rotation through a coronal mass ejection (CME) have the potential to improve our understanding of the CME’s plasma structure. We report recent results from simultaneous white-light coronagraph and radio observations made of a CME in July 2015. We made radio observations using the Karl G. Jansky Very Large Array (VLA) at 1 - 2 GHz frequencies of a set of cosmic radio sources through the solar corona at heliocentric distances that ranged between 8 - 23 solar radii. A unique aspect of these observations is that the CME occulted several of these radio sources and, therefore, our Faraday rotation measurements provide information on the plasma structure in different regions of the CME. We successfully measured CME-induced Faraday rotation along multiple lines of sight because we made special arrangements with the staff at the National Radio Astronomy Observatory to trigger VLA observations when a candidate CME appeared low in the corona in near real-time images from the Large Angle and Spectrometric Coronagraph (LASCO) C2 instrument.

  20. The application of radiotracer technique for preconcentration neutron activation analysis

    International Nuclear Information System (INIS)

    Wang Xiaolin; Chen Yinliang; Sun Ying; Fu Yibei

    1995-01-01

    The application of radiotracer technique for preconcentration neutron activation analysis (Pre-NAA) are studied and the method for determination of chemical yield of Pre-NAA is developed. This method has been applied to determination of gold, iridium and rhenium in steel and rock samples and the contents of noble metal are in the range of 1-20 ng·g -1 (sample). In addition, the accuracy difference caused by determination of chemical yield between RNAA and Pre-NAA are also discussed

  1. Transfer matrix approach for the Kerr and Faraday rotation in layered nanostructures

    International Nuclear Information System (INIS)

    Széchenyi, Gábor; Vigh, Máté; Cserti, József; Kormányos, Andor

    2016-01-01

    To study the optical rotation of the polarization of light incident on multilayer systems consisting of atomically thin conductors and dielectric multilayers we present a general method based on transfer matrices. The transfer matrix of the atomically thin conducting layer is obtained using the Maxwell equations. We derive expressions for the Kerr (Faraday) rotation angle and for the ellipticity of the reflected (transmitted) light as a function of the incident angle and polarization of the light. The method is demonstrated by calculating the Kerr (Faraday) angle for bilayer graphene in the quantum anomalous Hall state placed on the top of dielectric multilayers. The optical conductivity of the bilayer graphene is calculated in the framework of a four-band model. (paper)

  2. Rotation of small clusters in sheared metallic glasses

    International Nuclear Information System (INIS)

    Delogu, Francesco

    2011-01-01

    Graphical abstract: When a Cu 50 Ti 50 metallic glass is shear-deformed, the irreversible rearrangement of local structures allows the rigid body rotation of clusters. Highlights: → A shear-deformed Cu 50 Ti 50 metallic glass was studied by molecular dynamics. → Atomic displacements occur at irreversible rearrangements of local structures. → The dynamics of such events includes the rigid body rotation of clusters. → Relatively large clusters can undergo two or more complete rotations. - Abstract: Molecular dynamics methods were used to simulate the response of a Cu 50 Ti 50 metallic glass to shear deformation. Attention was focused on the atomic displacements taking place during the irreversible rearrangement of local atomic structures. It is shown that the apparently disordered dynamics of such events hides the rigid body rotation of small clusters. Cluster rotation was investigated by evaluating rotation angle, axis and lifetimes. This permitted to point out that relatively large clusters can undergo two or more complete rotations.

  3. Primordial gravitational waves measurements and anisotropies of CMB polarization rotation

    Directory of Open Access Journals (Sweden)

    Si-Yu Li

    2015-12-01

    Full Text Available Searching for the signal of primordial gravitational waves in the B-modes (BB power spectrum is one of the key scientific aims of the cosmic microwave background (CMB polarization experiments. However, this could be easily contaminated by several foreground issues, such as the interstellar dust grains and the galactic cyclotron electrons. In this paper we study another mechanism, the cosmic birefringence, which can be introduced by a CPT-violating interaction between CMB photons and an external scalar field. Such kind of interaction could give rise to the rotation of the linear polarization state of CMB photons, and consequently induce the CMB BB power spectrum, which could mimic the signal of primordial gravitational waves at large scales. With the recently released polarization data of BICEP2 and the joint analysis data of BICEP2/Keck Array and Planck, we perform a global fitting analysis on constraining the tensor-to-scalar ratio r by considering the polarization rotation angle [α(nˆ] which can be separated into a background isotropic part [α¯] and a small anisotropic part [Δα(nˆ]. Since the data of BICEP2 and Keck Array experiments have already been corrected by using the “self-calibration” method, here we mainly focus on the effects from the anisotropies of CMB polarization rotation angle. We find that including Δα(nˆ in the analysis could slightly weaken the constraints on the tensor-to-scalar ratio r, when using current CMB polarization measurements. We also simulate the mock CMB data with the BICEP3-like sensitivity. Very interestingly, we find that if the effects of the anisotropic polarization rotation angle could not be taken into account properly in the analysis, the constraints on r will be dramatically biased. This implies that we need to break the degeneracy between the anisotropies of the CMB polarization rotation angle and the CMB primordial tensor perturbations, in order to measure the signal of primordial

  4. Giant enhancement of Kerr rotation in two-dimensional Bismuth iron garnet/Ag photonic crystals

    International Nuclear Information System (INIS)

    Liang Hong; Zhang Qiang; Liu Huan; Fu Shu-Fang; Zhou Sheng; Wang Xuan-Zhang

    2015-01-01

    Kerr effects of two-dimensional (2D) Bismuth iron garnet (BIG)/Ag photonic crystals (PCs) combined magnetic and plasmonic functionalities is investigated with the effective medium theory. An analytical expression of Kerr rotation angles is derived, in which the effects of the surface pasmons polaritons (SPP) on magneto–optical (MO) activities are reflected. The largest enhancement of Kerr rotation up to now is demonstrated, which is improved three orders of magnitude compared with that of BIG film. When λ < 750 nm all of the reflection are over 10% for the arbitrary filling ratio f 1 , in addition, the enhancement of Kerr rotation angles are at least one order of magnitude. (paper)

  5. Synthesis of optical holograms of rotating objects

    International Nuclear Information System (INIS)

    Bogdanova, T.V.; Titar', V.P.; Tomchuk, E.Ya.

    1998-01-01

    A method of synthesis of rotating objects is analyzed and its advantages over the previously known methods and restrictions caused by the nonlinear character of motion of objects being studied are determined. Numerical simulation is used to study properties of synthesized holograms and the images reconstructed with their help. The resolving power of synthesized holograms is determined. The pulsed response of the system used for the synthesis of rotating objects is studied and its isoplanar sections are determined. It is shown that in the optical range, in contrast to the radio-frequency range, one can synthesize holograms and reconstruct visual images not only of rotating objects, but of vibrating objects as well. For small angles of object rotation (0.0025 rad), an image with a high resolution power (0.0004 m) can be obtained

  6. Rotation of the swing plane of Foucault's pendulum and Thomas spin precession: two sides of one coin

    Energy Technology Data Exchange (ETDEWEB)

    Krivoruchenko, Mikhail I [Alikhanov Institute for Theoretical and Experimental Physics, Russian Federation State Scientific Center, Moscow (Russian Federation)

    2009-08-31

    Using elementary geometric tools, we apply essentially the same methods to derive expressions for the rotation angle of the swing plane of Foucault's pendulum and the rotation angle of the spin of a relativistic particle moving in a circular orbit (the Thomas precession effect). (methodological notes)

  7. Determination of the particle size distribution in a powder using radiotracers

    International Nuclear Information System (INIS)

    Revilla D, R.

    1974-01-01

    To determine experimentally the particle size distribution in a powder the meshed method is generally used. This method has the disadvantage that in the obtained distribution is not observed at detail the fine structure of such distribution. In this work, a method for obtaining the distribution of particle size using radiotracers is presented. In the obtained distribution by this method it is observed with more detail the fine structure of the distribution, comparing with the obtained results by the classical method of meshed. The radiotracer method has major resolution for the experimental determination mentioned. In the chapter 1, it is done a brief analysis about theoretical aspects related with the method. In the first part it is analysed the particle behavior (sedimenting) in a fluid. The second part treats the relating with the radioactivity of an activated material as well as its detection. In the chapter 2, a description of the method is done also the experimental problems to applying to the alumina crystals sample are discussed. In the chapter 3 the obtained results and the mistake calculations in such results are showed. Finally, in the chapter 4 the conclusions and recommendations are given which is possible to obtain better results and improve to those in this work were obtained. (Author)

  8. Can arthroscopic rotator cuff repair prevent proximal migration of the humeral head?

    Directory of Open Access Journals (Sweden)

    Pablo Sanz-Ruiz

    2015-12-01

    Full Text Available Introduction: Shoulder arthroscopy has become increasingly used in recent years, especially in rotator cuff repair. The purpose of this study was to determine whether arthroscopic rotator cuff repair could prevent proximal migration of the humeral head. Material and Methods: We performed a retrospective study of 56 patients suffering from shoulder pain. They were divided into two groups, one comprising patients with impingement syndrome who underwent acromioplasty only and another comprising patients with rotator cuff tear who underwent acromioplasty combined with rotator cuff repair. The pre-operative Hirooka angle and the results of the simple shoulder test (SST were compared after 1 year. Results: We found no differences between the groups for the Hirooka angle or SST results. We did find a significant difference (P<0.05 between pre-operative and post-operative SST results. Conclusions: Rotator cuff repair using arthroscopy is a minimally invasive procedure that improves function and prevents proximal migration of the humeral head after 1 year of follow-up. [Arch Clin Exp Surg 2015; 4(4.000: 190-195

  9. Action-angle variables for spherical mechanics related to near horizon extremal Myers–Perry black hole

    International Nuclear Information System (INIS)

    Galajinsky, Anton; Nersessian, Armen; Saghatelian, Armen

    2013-01-01

    The action-angle formulation for the spherical part of the conformal mechanics describing a massive relativistic particle moving near the horizon of an extremal rotating black hole in arbitrary dimension is presented for the special case that all rotation parameters are equal

  10. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    International Nuclear Information System (INIS)

    Sugiharto, S.; Kurniadi, R.; Abidin, Z.; Stegowski, Z.; Furman, L.

    2013-01-01

    Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT) having an inner diameter of 24 in (60,96 m). The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD) curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD) simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct. (author)

  11. Prediction of Separation Length of Turbulent Multiphase Flow Using Radiotracer and Computational Fluid Dynamics Simulation

    Directory of Open Access Journals (Sweden)

    S. Sugiharto1

    2013-04-01

    Full Text Available Multiphase flow modeling presents great challenges due to its extreme importance in various industrial and environmental applications. In the present study, prediction of separation length of multiphase flow is examined experimentally by injection of two kinds of iodine-based radiotracer solutions into a hydrocarbon transport pipeline (HCT having an inner diameter of 24 in (60,96 m. The main components of fluids in the pipeline are water 95%, crude oil 3% and gas 2%. A radiotracing experiment was carried out at the segment of pipe which is located far from branch points with assumptions that stratified flows in such segment were achieved. Two radiation detectors located at 80 and 100 m from injection point were used to generate residence time distribution (RTD curve resulting from injection of radiotracer solutions. Multiphase computational fluid dynamics (CFD simulations using Eulerian-Eulerian control volume and commercial CFD package Fluent 6.2 were employed to simulate separation length of multiphase flow. The results of study shows that the flow velocity of water is higher than the flow rate of crude oil in water-dominated system despite the higher density of water than the density of the crude oil. The separation length in multiphase flow predicted by Fluent mixture model is approximately 20 m, measured from injection point. This result confirms that the placement of the first radiation detector at the distance 80 m from the injection point was correct

  12. Midplane Faraday rotation: A densitometer for large tokamaks

    International Nuclear Information System (INIS)

    Jobes, F.C.; Mansfield, D.K.

    1992-01-01

    The density in a large tokamak such as International Thermonuclear Experimental Reactor (ITER), or any of the proposed future US machines, can be determined by measuring the Faraday rotation of a 10.6 μm laser directed tangent to the toroidal field. If there is a horizontal array of such beams, then n e (R) can be readily obtained with a simple Abel inversion about the center line of the tokamak. For a large machine, operated at a full field of 30 T m and a density of 2x10 20 /m 3 , the rotation angle would be quite large-about 60 degree for two passes. A layout in which a single laser beam is fanned out in the horizontal midplane of the tokamak, with a set of retroreflectors on the far side of the vacuum vessel, would provide good spatial resolution, depending only upon the number of reflectors. With this proposed layout, only one window would be needed. Because the rotation angle is never more than 1 ''fringe,'' the data is always good, and it is also a continuous measurement in time. Faraday rotation is dependent only upon the plasma itself, and thus is not sensitive to vibration of the optical components. Simulations of the expected results show that ITER, or any large tokamak, existing or proposed, would be well served even at low densities by a midplane Faraday rotation densitometer of ∼64 channels

  13. Multiple rotation assessment through isothetic fringes in speckle photography

    International Nuclear Information System (INIS)

    Angel, Luciano; Tebaldi, Myrian; Bolognini, Nestor

    2007-01-01

    The use of different pupils for storing each speckled image in speckle photography is employed to determine multiple in-plane rotations. The method consists of recording a four-exposure specklegram where the rotations are done between exposures. This specklegram is then optically processed in a whole field approach rendering isothetic fringes, which give detailed information about the multiple rotations. It is experimentally demonstrated that the proposed arrangement permits the depiction of six isothetics in order to measure either six different angles or three nonparallel components for two local general in-plane displacements

  14. Grain boundary motion and grain rotation in aluminum bicrystals: recent experiments and simulations

    International Nuclear Information System (INIS)

    Molodov, D A; Barrales-Mora, L A; Brandenburg, J-E

    2015-01-01

    The results of experimental and computational efforts over recent years to study the motion of geometrically different grain boundaries and grain rotation under various driving forces are briefly reviewed. Novel in-situ measuring techniques based on orientation contrast imaging and applied simulation techniques are described. The experimental results obtained on specially grown aluminum bicrystals are presented and discussed. Particularly, the faceting and migration behavior of low angle grain boundaries under the curvature force is addressed. In contrast to the pure tilt boundaries, which remained flat/faceted and immobile during annealing at elevated temperatures, mixed tilt-twist boundaries readily assumed a curved shape and steadily moved under the capillary force. Computational analysis revealed that this behavior is due to the inclinational anisotropy of grain boundary energy, which in turn depends on boundary geometry. The shape evolution and shrinkage kinetics of cylindrical grains with different tilt and mixed boundaries were studied by molecular dynamics simulations. The mobility of low angle <100> boundaries with misorientation angles higher than 10°, obtained by both the experiments and simulations, was found not to differ from that of the high angle boundaries, but decreases essentially with further decrease of misorientation. The shape evolution of the embedded grains in simulations was found to relate directly to results of the energy computations. Further simulation results revealed that the shrinkage of grains with pure tilt boundaries is accompanied by grain rotation. In contrast, grains with the tilt-twist boundaries composed of dislocations with the mixed edge-screw character do not rotate during their shrinkage. Stress driven boundary migration in aluminium bicrystals was observed to be coupled to a tangential translation of the grains. The activation enthalpy of high angle boundary migration was found to vary non-monotonically with

  15. Cardiac motion correction based on partial angle reconstructed images in x-ray CT

    International Nuclear Information System (INIS)

    Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom

    2015-01-01

    Purpose: Cardiac x-ray CT imaging is still challenging due to heart motion, which cannot be ignored even with the current rotation speed of the equipment. In response, many algorithms have been developed to compensate remaining motion artifacts by estimating the motion using projection data or reconstructed images. In these algorithms, accurate motion estimation is critical to the compensated image quality. In addition, since the scan range is directly related to the radiation dose, it is preferable to minimize the scan range in motion estimation. In this paper, the authors propose a novel motion estimation and compensation algorithm using a sinogram with a rotation angle of less than 360°. The algorithm estimates the motion of the whole heart area using two opposite 3D partial angle reconstructed (PAR) images and compensates the motion in the reconstruction process. Methods: A CT system scans the thoracic area including the heart over an angular range of 180° + α + β, where α and β denote the detector fan angle and an additional partial angle, respectively. The obtained cone-beam projection data are converted into cone-parallel geometry via row-wise fan-to-parallel rebinning. Two conjugate 3D PAR images, whose center projection angles are separated by 180°, are then reconstructed with an angular range of β, which is considerably smaller than a short scan range of 180° + α. Although these images include limited view angle artifacts that disturb accurate motion estimation, they have considerably better temporal resolution than a short scan image. Hence, after preprocessing these artifacts, the authors estimate a motion model during a half rotation for a whole field of view via nonrigid registration between the images. Finally, motion-compensated image reconstruction is performed at a target phase by incorporating the estimated motion model. The target phase is selected as that corresponding to a view angle that is orthogonal to the center view angles of

  16. Cardiac motion correction based on partial angle reconstructed images in x-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seungeon; Chang, Yongjin; Ra, Jong Beom, E-mail: jbra@kaist.ac.kr [Department of Electrical Engineering, KAIST, Daejeon 305-701 (Korea, Republic of)

    2015-05-15

    Purpose: Cardiac x-ray CT imaging is still challenging due to heart motion, which cannot be ignored even with the current rotation speed of the equipment. In response, many algorithms have been developed to compensate remaining motion artifacts by estimating the motion using projection data or reconstructed images. In these algorithms, accurate motion estimation is critical to the compensated image quality. In addition, since the scan range is directly related to the radiation dose, it is preferable to minimize the scan range in motion estimation. In this paper, the authors propose a novel motion estimation and compensation algorithm using a sinogram with a rotation angle of less than 360°. The algorithm estimates the motion of the whole heart area using two opposite 3D partial angle reconstructed (PAR) images and compensates the motion in the reconstruction process. Methods: A CT system scans the thoracic area including the heart over an angular range of 180° + α + β, where α and β denote the detector fan angle and an additional partial angle, respectively. The obtained cone-beam projection data are converted into cone-parallel geometry via row-wise fan-to-parallel rebinning. Two conjugate 3D PAR images, whose center projection angles are separated by 180°, are then reconstructed with an angular range of β, which is considerably smaller than a short scan range of 180° + α. Although these images include limited view angle artifacts that disturb accurate motion estimation, they have considerably better temporal resolution than a short scan image. Hence, after preprocessing these artifacts, the authors estimate a motion model during a half rotation for a whole field of view via nonrigid registration between the images. Finally, motion-compensated image reconstruction is performed at a target phase by incorporating the estimated motion model. The target phase is selected as that corresponding to a view angle that is orthogonal to the center view angles of

  17. Investigation of liquid phase axial dispersion in Taylor bubble flow by radiotracer residence time distribution analysis

    Directory of Open Access Journals (Sweden)

    Jin J.H.

    2013-05-01

    Full Text Available A gas-liquid Taylor bubble flow occurs in small diameter channels in which gas bubbles are separated by slugs of pure liquid. This type of flow regime is well suited for solid catalyzed gas-liquid reactors in which the reaction efficiency is a strong function of axial dispersion in the regions of pure liquid. This paper presents an experimental study of liquid phase axial dispersion in a Taylor bubble flow developed in a horizontal tube using high speed photography and radiotracer residence time distribution (RTD analysis. A parametric dependence of axial dispersion on average volume fraction of gas phase was also investigated by varying the relative volumetric flow rates of the two phases. 137mBa produced from a 137Cs/137mBa radionuclide generator was used as radiotracer and measurements were made using the NaI(Tl scintillation detectors. Validation of 137mBa in the form of barium chloride as aqueous phase radiotracer was also carried out. Axial Dispersion Model (ADM was used to simulate the hydrodynamics of the system and the results of the experiment are presented. It was observed that the system is characterized by very high values of Peclet Number (Pe∼102 which reveals an approaching plug type flow. The experimental and model estimated values of mean residence times were observed in agreement with each other.

  18. Development of a system for real-time measurements of metabolite transport in plants using short-lived positron-emitting radiotracers

    Science.gov (United States)

    Kiser, Matthew R.

    Over the past 200 years, the Earth's atmospheric carbon dioxide (CO 2) concentration has increased by more than 35%, and climate experts predict that CO2 levels may double by the end of this century. Understanding the mechanisms of resource management in plants is fundamental for predicting how plants will respond to the increase in atmospheric CO 2. Plant productivity sustains life on Earth and is a principal component of the planet's system that regulates atmospheric CO2 concentration. As such, one of the central goals of plant science is to understand the regulatory mechanisms of plant growth in a changing environment. Short-lived positron-emitting radiotracer techniques provide time-dependent data that are critical for developing models of metabolite transport and resource distribution in plants and their microenvironments. To better understand the effects of environmental changes on resource transport and allocation in plants, we have developed a system for real-time measurements of rnetabolite transport in plants using short-lived positron-emitting radio-tracers. This thesis project includes the design, construction, and demonstration of the capabilities of this system for performing real-time measurements of metabolite transport in plants. The short-lived radiotracer system described in this dissertation takes advantage of the combined capabilities and close proximity of two research facilities at. Duke University: the Triangle Universities Nuclear Laboratory (TUNL) and the Duke University Phytotron, which are separated by approximately 100 meters. The short-lived positron-emitting radioisotopes are generated using the 10-MV tandem Van de Graaff accelerator located in the main TUNL building, which provides the capability of producing short-lived positron-emitting isotopes such as carbon-11 (11C: 20 minute half-life), nitrogen-13 (13N; 10 minute half-life), fluorine-18 (18F; 110 minute half-life), and oxygen-15 (15O; 2 minute half-life). The radioisotopes may

  19. FUEL CONTAMINATION IN A MARINE DIESEL ENGINE. A RADIOTRACER STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, B. E.

    1964-04-15

    A radiotracer method was applied to the problem of elucidating the mechanism of contamination of crankcase oil by fuel combustion products in a marine diesel engine. The method consisted of adding an oil soluble radioisotope to the fuel and tracing its route to the various lubricants used in the engine. It was found that of the total amount of combustion products and by-products which enter the crankcase oil, 65% enters by simple contamination via reintroduction of used cylinder lubricant and 35% by a condensation mechanism. (auth)

  20. Design & fabrication of two seated aircraft with an advanced rotating leading edge wing

    Science.gov (United States)

    Al Ahmari, Saeed Abdullah Saeed

    The title of this thesis is "Design & Fabrication of two Seated Aircraft with an Advanced Rotating Leading Edge Wing", this gives almost a good description of the work has been done. In this research, the moving surface boundary-layer control (MSBC) concept was investigated and implemented. An experimental model was constructed and tested in wind tunnel to determine the aerodynamic characteristics using the leading edge moving surface of modified semi-symmetric airfoil NACA1214. The moving surface is provided by a high speed rotating cylinder, which replaces the leading edge of the airfoil. The angle of attack, the cylinder surfaces velocity ratio Uc/U, and the flap deflection angle effects on the lift and drag coefficients and the stall angle of attack were investigated. This new technology was applied to a 2-seat light-sport aircraft that is designed and built in the Aerospace Engineering Department at KFUPM. The project team is led by the aerospace department chairman Dr. Ahmed Z. AL-Garni and Dr. Wael G. Abdelrahman and includes graduate and under graduate student. The wing was modified to include a rotating cylinder along the leading edge of the flap portion. This produced very promising results such as the increase of the maximum lift coefficient at Uc/U=3 by 82% when flaps up and 111% when flaps down at 40° and stall was delayed by 8degrees in both cases. The laboratory results also showed that the effective range of the leading-edge rotating cylinder is at low angles of attack which reduce the need for higher angles of attack for STOL aircraft.

  1. Improving the Geolocation Algorithm for Sensors Onboard the ISS: Effect of Drift Angle

    Directory of Open Access Journals (Sweden)

    Changyong Dou

    2014-05-01

    Full Text Available The drift angle caused by the Earth’s self-rotation may introduce rotational displacement artifact on the geolocation results of imagery acquired by an Earth observing sensor onboard the International Space Station (ISS. If uncorrected, it would cause a gradual degradation of positional accuracy from the center towards the edges of an image. One correction method to account for the drift angle effect was developed. The drift angle was calculated from the ISS state vectors and positional information of the ground nadir point of the imagery. Tests with images acquired by the International Space Station Agriculture Camera (ISSAC using Google EarthTM as a reference indicated that applying the drift angle correction can reduce the residual geolocation error for the corner points of the ISSAC images from over 1000 to less than 500 m. The improved geolocation accuracy is well within the inherent geolocation uncertainty of up to 800 m, mainly due to imprecise knowledge of the ISS attitude and state parameters required to perform the geolocation algorithm.

  2. Correlations between the alpha angle and femoral head asphericity: Implications and recommendations for the diagnosis of cam femoroacetabular impingement

    International Nuclear Information System (INIS)

    Harris, Michael D.; Kapron, Ashley L.; Peters, Christopher L.; Anderson, Andrew E.

    2014-01-01

    Objective: To determine the strength of common radiographic and radial CT views for measuring true femoral head asphericity. Patients and methods: In 15 patients with cam femoroacetabular impingement (FAI) and 15 controls, alpha angles were measured by two observers using radial CT (0°, 30°, 60°, 90°) and digitally reconstructed radiographs (DRRs) for the: anterior–posterior (AP), standing frog-leg lateral, 45° Dunn with neutral rotation, 45° Dunn with 40° external rotation, and cross-table lateral views. A DRR validation study was performed. Alpha angles were compared between groups. Maximum deviation from a sphere of each subject was obtained from a previous study. Alpha angles from each view were correlated with maximum deviation. Results: There were no significant differences between alpha angles measured on radiographs and the corresponding DRRs (p = 0.72). Alpha angles were significantly greater in patients for all views (p ≤ 0.002). Alpha angles from the 45° Dunn with 40° external rotation, cross-table lateral, and 60° radial views had the strongest correlations with maximum deviation (r = 0.831; r = 0.823; r = 0.808, respectively). The AP view had the weakest correlation (r = 0.358). Conclusion: DRRs were a validated means to simulate hip radiographs. The 45° Dunn with 40° external rotation, cross-table lateral, and 60° radial views best visualized femoral asphericity. Although commonly used, the AP view did not visualize cam deformities well. Overall, the magnitude of the alpha angle may not be indicative of the size of the deformity. Thus, 3D reconstructions and measurements of asphericity could improve the diagnosis of cam FAI

  3. Examination into the maximum rotational frequency for an in-plane switched active waveplate device

    International Nuclear Information System (INIS)

    Davidson, A J; Elston, S J; Raynes, E P

    2005-01-01

    An examination of an active waveplate device using a one-dimensional model, giving numerical and analytical results, is presented. The model calculates the director and twist configuration by minimizing the free energy of the system with simple homeotropic boundary conditions. The effect of varying the in-plane electric field in both magnitude and direction is examined, and it is shown that the twist through the cell is constant in time as the field is rotated. As the electric field is rotated, the director field lags behind by an angle which increases as the frequency of the electric field rotation increases. When this angle reaches approximately π/4 the director field no longer follows the electric field in a uniform way. Using mathematical analysis it is shown that the conditions on which the director profile will fail to follow the rotating electric field depend on the frequency of electric field rotation, the magnitude of the electric field, the dielectric anisotropy and the viscosity of the liquid crystal

  4. Frontal Changes in the Lower Face After Clockwise Rotation of the Maxillomandibular Complex Without Perisurgical Orthodontic Treatment in Angle Class I and Skeletal Class III Women.

    Science.gov (United States)

    Lee, Sang Woo; Cho, Jeongmok; Kim, Kikap; Ahn, Seung Hyun

    2017-06-01

    Orthognathic surgery has become more popular to slenderize a wide lower face and to improve facial esthetics in Asian patients with normal occlusion. Clockwise rotation (CR) of the maxillomandibular complex (MMC) steepens the mandibular plane. This study performed a quantitative analysis on the influence of CR on slenderness of the lower face from the frontal view. This retrospective study included 36 female patients with Angle Class I occlusion and skeletal Class III pattern. The subjects underwent CR of the MMC without perioperative orthodontic treatment and change in the occlusion only for the purpose of esthetic improvement. Linear and angular variables were measured on a cephalogram and three-dimensional computed tomography (3D CT) obtained before and at least 6 months after surgery. Data were analyzed using paired t tests and Spearman correlations. Univariate regression analysis was used to predict the postoperative change according to the amount of posterior impaction. The mean posterior impaction was 3.81 mm. All mandibular plane angle (MPA) measurements were increased (ranged from 5.69° to 13.12°, p lower face becomes narrower and more slender as the MMC rotates in a clockwise direction. Orthognathic surgery with CR has the advantage of increasing the MPAs and obtaining natural soft tissue contouring while minimizing the amount of bone resection. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266c .

  5. Quantitative Analysis of the Association Angle between T-cell Receptor Vα/Vβ Domains Reveals Important Features for Epitope Recognition.

    Directory of Open Access Journals (Sweden)

    Thomas Hoffmann

    2015-07-01

    Full Text Available T-cell receptors (TCR play an important role in the adaptive immune system as they recognize pathogen- or cancer-based epitopes and thus initiate the cell-mediated immune response. Therefore there exists a growing interest in the optimization of TCRs for medical purposes like adoptive T-cell therapy. However, the molecular mechanisms behind T-cell signaling are still predominantly unknown. For small sets of TCRs it was observed that the angle between their Vα- and Vβ-domains, which bind the epitope, can vary and might be important for epitope recognition. Here we present a comprehensive, quantitative study of the variation in the Vα/Vβ interdomain-angle and its influence on epitope recognition, performing a systematic bioinformatics analysis based on a representative set of experimental TCR structures. For this purpose we developed a new, cuboid-based superpositioning method, which allows a unique, quantitative analysis of the Vα/Vβ-angles. Angle-based clustering led to six significantly different clusters. Analysis of these clusters revealed the unexpected result that the angle is predominantly influenced by the TCR-clonotype, whereas the bound epitope has only a minor influence. Furthermore we could identify a previously unknown center of rotation (CoR, which is shared by all TCRs. All TCR geometries can be obtained by rotation around this center, rendering it a new, common TCR feature with the potential of improving the accuracy of TCR structure prediction considerably. The importance of Vα/Vβ rotation for signaling was confirmed as we observed larger variances in the Vα/Vβ-angles in unbound TCRs compared to epitope-bound TCRs. Our results strongly support a two-step mechanism for TCR-epitope: First, preformation of a flexible TCR geometry in the unbound state and second, locking of the Vα/Vβ-angle in a TCR-type specific geometry upon epitope-MHC association, the latter being driven by rotation around the unique center of rotation.

  6. Applications of Beta Particle Detection for Synthesis and Usage of Radiotracers Developed for Positron Emission Tomography

    Science.gov (United States)

    Dooraghi, Alex Abreu

    Positron Emission Tomography (PET) is a noninvasive molecular imaging tool that requires the use of a radioactive compound or radiotracer which targets a molecular pathway of interest. We have developed and employed three beta particle radiation detection systems to advance PET. Specifically, the goals of these systems are to: 1. Automate dispensing of solutions containing a positron emitting isotope. 2. Monitor radioactivity on-chip during synthesis of a positron emitting radiotracer. 3. Assay cellular uptake on-chip of a positron emitting radiotracer. Automated protocols for measuring and dispensing solutions containing radioisotopes are essential not only for providing an optimum environment for radiation workers, but also to ensure a quantitatively accurate workflow. For the first project, we describe the development and performance of a system for automated radioactivity distribution of beta particle emitting radioisotopes such as fluorine-18 (F-18). Key to the system is a radiation detector in-line with a peristaltic pump. The system demonstrates volume accuracy within 5 % for volumes of 20 muL or greater. When considering volumes of 20 muL or greater, delivered radioactivity is in agreement with the requested radioactivity as measured with the dose calibrator. The integration of the detector and pump leads to a flexible system that can accurately dispense solutions containing F-18 in radioactivity concentrations directly produced from a cyclotron (~ 0.1-1 mCi/muL), to low activity concentrations intended for preclinical mouse scans (~ 1-10 muCi/muL), and anywhere in between. Electrowetting on dielectric (EWOD) is an attractive microfluidic platform for batch synthesis of PET radiotracers. Visualization of radioisotopes on-chip is critical for synthesis optimization and technological development. For the second project, we describe the development and performance of a Cerenkov/real-time imaging system for PET radiotracer synthesis on EWOD. We also investigate

  7. An investigation of the structure of rotational discontinuities

    International Nuclear Information System (INIS)

    Goodrich, C.C.; Cargill, P.J.

    1991-01-01

    The structure of rotational discontinuities (RDs) has been studied through hybrid simulations for a range of propagation angle Θ bn between the discontinuity normal and the upstream magnetic field and plasma β. For sufficiently narrow initial states, the simulations produce quasi-steady reverse rotation magnetic field structures for 30 degree ≤ Θ bn ≤ 60 degree and 0 i -1 . This structure is characterized by a right handed field rotation upstream joined smoothly to a left handed field rotation downstream; its width decreases from 60-70 c/ω pi at Θ bn = 30 degree to less than 25 c/ω pi at Θ bn = 60 degree. The magnetic field hodograms of the RD results have a distinctive S-shape which is most pronounced in simulations with small Θ bn and initially right handed rotations. The reverse rotation structure is the net result of the expansion of the initial current layer via the fast and intermediate wave modes

  8. Preferred nasolabial angle in Middle Eastern population.

    Science.gov (United States)

    Alharethy, Sami

    2017-05-01

    To define the preferred nasolabial angle measurement in Middle Eastern population. An observational study was conducted from January 2012 to January 2016 at the Department of Otolaryngology, Head and Neck Surgery, King Abdulaziz University Hospital, King Saud University, Riyadh, Kingdom of Saudi Arabia. A total of 1027 raters, 506 males, and 521 females were asked to choose the most ideal nasolabial angle for 5 males and 5 females lateral photographs whose nasolabial angle were modified with Photoshop into the following angles (85°, 90°, 95°, 100°, 105°, and 110°). Male raters preferred the angle of 89.5° ± 3.5° (mean ± SD) for males and 90.8° ± 5.6° for females. While female raters preferred the angle of 89.3° ± 3.8° for males and 90.5° ± 4.8° for females. ANOVA test compare means among groups: p: 0.342, and there is no statistically significant difference between groups. The results of our study showed an even more acute angles than degrees found in the literature. It shows that what young generation in our region prefers and clearly reflects that what could be explained as under rotation of the nasal tip in other cultures is just the ideal for some Middle Eastern population.

  9. Spherical null geodesics of rotating Kerr black holes

    International Nuclear Information System (INIS)

    Hod, Shahar

    2013-01-01

    The non-equatorial spherical null geodesics of rotating Kerr black holes are studied analytically. Unlike the extensively studied equatorial circular orbits whose radii are known analytically, no closed-form formula exists in the literature for the radii of generic (non-equatorial) spherical geodesics. We provide here an approximate formula for the radii r ph (a/M;cosi) of these spherical null geodesics, where a/M is the dimensionless angular momentum of the black hole and cos i is an effective inclination angle (with respect to the black-hole equatorial plane) of the orbit. It is well-known that the equatorial circular geodesics of the Kerr spacetime (the prograde and the retrograde orbits with cosi=±1) are characterized by a monotonic dependence of their radii r ph (a/M;cosi=±1) on the dimensionless spin-parameter a/M of the black hole. We use here our novel analytical formula to reveal that this well-known property of the equatorial circular geodesics is actually not a generic property of the Kerr spacetime. In particular, we find that counter-rotating spherical null orbits in the range (3√(3)−√(59))/4≲cosi ph (a/M;cosi=const) on the dimensionless rotation-parameter a/M of the black hole. Furthermore, it is shown that spherical photon orbits of rapidly-rotating black holes are characterized by a critical inclination angle, cosi=√(4/7), above which the coordinate radii of the orbits approach the black-hole radius in the extremal limit. We prove that this critical inclination angle signals a transition in the physical properties of the spherical null geodesics: in particular, it separates orbits which are characterized by finite proper distances to the black-hole horizon from orbits which are characterized by infinite proper distances to the horizon.

  10. Nanoparticles in dilute solution : A numerical study of rotational diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Evensen, Tom Richard

    2008-06-15

    This thesis is dedicated to Brownian dynamics simulations of rotational diffusion. A rotation dynamics engine has been implemented and tested. This engine will in the future be integrated as a part of a complete Brownian dynamics simulation tool. The special case, when translational motion can be ignored, has thoroughly been studied. Two choices of generalized coordinates describing angular orientation of the particles are used. The Euler angles, which constitute the classical choice, and the Cartesian components of the rotation vector, which was recently introduced as an alternative, are being compared with regards to computational efficiency. Results from both equilibrium and non-equilibrium simulations are presented. The consistency of two new algorithms is demonstrated on systems of free rigid particles with arbitrary surface topographies. The algorithms make use of only the principal values of the rotational mobility tensor, assuming the corresponding principal axes coincide with the body-fixed coordinate system. These three scalars contain all information about the particle surface topography relevant for rotational diffusion. The calculation of the mobility tensor can be performed in a pre-calculation step, which makes the algorithm itself highly efficient. Both choices of generalized coordinates correctly reproduce theoretical predictions, but we have found that the algorithm using the Cartesian components of the rotation vector as generalized coordinates outperform its counterpart using the Euler angles by up to a factor 1000 in extreme cases. The reason for this improvement is that the algorithm using the Cartesian components of the rotation vector is free of singularities. (Author). refs. figs

  11. Using Order Tracking Analysis Method to Detect the Angle Faults of Blades on Wind Turbine

    DEFF Research Database (Denmark)

    Li, Pengfei; Hu, Weihao; Liu, Juncheng

    2016-01-01

    The angle faults of blades on wind turbines are usually included in the set angle fault and the pitch angle fault. They are occupied with a high proportion in all wind turbine faults. Compare with the traditional fault detection methods, using order tracking analysis method to detect angle faults....... By analyzing and reconstructing the fault signals, it is easy to detect the fault characteristic frequency and see the characteristic frequencies of angle faults depend on the shaft rotating frequency, which is known as the 1P frequency and 3P frequency distinctly....

  12. Full-angle tomographic phase microscopy of flowing quasi-spherical cells.

    Science.gov (United States)

    Villone, Massimiliano M; Memmolo, Pasquale; Merola, Francesco; Mugnano, Martina; Miccio, Lisa; Maffettone, Pier Luca; Ferraro, Pietro

    2017-12-19

    We report a reliable full-angle tomographic phase microscopy (FA-TPM) method for flowing quasi-spherical cells along microfluidic channels. This method lies in a completely passive optical system, i.e. mechanical scanning or multi-direction probing of the sample is avoided. It exploits the engineered rolling of cells while they are flowing along a microfluidic channel. Here we demonstrate significant progress with respect to the state of the art of in-flow TPM by showing a general extension to cells having almost spherical shapes while they are flowing in suspension. In fact, the adopted strategy allows the accurate retrieval of rotation angles through a theoretical model of the cells' rotation in a dynamic microfluidic flow by matching it with phase-contrast images resulting from holographic reconstructions. So far, the proposed method is the first and the only one that permits to get in-flow TPM by probing the cells with full-angle, achieving accurate 3D refractive index mapping and the simplest optical setup, simultaneously. Proof of concept experiments were performed successfully on human breast adenocarcinoma MCF-7 cells, opening the way for the full characterization of circulating tumor cells (CTCs) in the new paradigm of liquid biopsy.

  13. Urban-area extraction from polarimetric SAR image using combination of target decomposition and orientation angle

    Science.gov (United States)

    Zou, Bin; Lu, Da; Wu, Zhilu; Qiao, Zhijun G.

    2016-05-01

    The results of model-based target decomposition are the main features used to discriminate urban and non-urban area in polarimetric synthetic aperture radar (PolSAR) application. Traditional urban-area extraction methods based on modelbased target decomposition usually misclassified ground-trunk structure as urban-area or misclassified rotated urbanarea as forest. This paper introduces another feature named orientation angle to improve urban-area extraction scheme for the accurate mapping in urban by PolSAR image. The proposed method takes randomness of orientation angle into account for restriction of urban area first and, subsequently, implements rotation angle to improve results that oriented urban areas are recognized as double-bounce objects from volume scattering. ESAR L-band PolSAR data of the Oberpfaffenhofen Test Site Area was used to validate the proposed algorithm.

  14. SU-E-P-45: An Analytical Formula for Deriving Mechanical Iso-Center of Rotational Gantry Treatment Unit Rotational Gantry Treatment Unit

    International Nuclear Information System (INIS)

    Ding, X; Bues, M

    2015-01-01

    Purpose: To present an analytical formula for deriving mechanical isocenter (MIC) of a rotational gantry treatment unit. The input data to the formula is obtained by a custom-made device. The formula has been implemented and used in an operational proton therapy facility since 2005. Methods: The custom made device consisted of 3 mutually perpendicular dial indicators and 5 clinometers, to obtain displacement data and gantry angle data simultaneously. During measurement, a steel sphere was affixed to the patient couch, and the device was attached to the snout rotating with the gantry. The displacement data and angle data were obtained simultaneously at angular increments of less than 1 degree. The analytical formula took the displacement and angle as input and derived the positions of dial indicator tips (DIT) position in room-fixed coordinate system. The formula derivation presupposes trigonometry and 3-dimentional coordinate transformations. Due to the symmetry properties of the defining equations, the DIT position can be solved for analytically without using mathematical approximations. We define the mean of all points in the DIT trajectory as the MIC. The formula was implemented in computer code, which has been employed during acceptance test, commissioning, as well as routine QA practice in an operational proton facility since 2005. Results: It took one minute for the custom-made device to acquire the measurement data for a full gantry rotation. The DIT trajectory and MIS are instantaneously available after the measurement. The MIC Result agrees well with vendor’s Result, which came from a different measurement setup, as well as different data analysis algorithm. Conclusion: An analytical formula for deriving mechanical isocenter was developed and validated. The formula is considered to be absolutely accurate mathematically. Be analyzing measured data of radial displacements as function of gantry angle, the formula calculates the MI position in room

  15. Fabrication of black-gold coatings by glancing angle deposition with sputtering

    Directory of Open Access Journals (Sweden)

    Alan Vitrey

    2017-02-01

    Full Text Available The fabrication of black-gold coatings using sputtering is reported here. Glancing angle deposition with a rotating substrate is needed to obtain vertical nanostructures. Enhanced light absorption is obtained in the samples prepared in the ballistic regime with high tilt angles. Under these conditions the diameter distribution of the nanostructures is centered at about 60 nm and the standard deviation is large enough to obtain black-metal behavior in the visible range.

  16. Imaging in hearing using radiotracers

    Directory of Open Access Journals (Sweden)

    Berding Georg

    2017-09-01

    Full Text Available Radiotracers offer unique options for brain imaging of functional and molecular processes related to hearing. Such imaging can be applied in a broad spectrum of situations from preclinical research to clinical patient care. Functional imaging to assess activation in brain regions and networks involved in auditory processing uses markers of blood flow or energy-metabolism in well-defined conditions with and without auditory stimulation. Molecular markers can be used in hearing research for example to study changes in inhibitory neurotransmission systems related to hearing loss. For imaging either positron emission tomography (PET or single-photon emission computed tomography (SPECT are employed. Data analysis can encompasses voxel-wise statistical analysis of activation and calculation of quantitative parameters like receptor binding-potentials based on bio-kinetic modeling. Functional imaging has been frequently used in the context of auditory implantation. Before implantation it aims to assess intactness of the central auditory pathway and prognosis. After implantation it is used to improve understanding of the outcome with respect to auditory function and finally speech understanding, e.g. by measuring correlates of central auditory processing and neuroplasticity.

  17. Radiotracer experiments on the uptake of radionuclides by mushrooms and vegetables

    International Nuclear Information System (INIS)

    Ban-Nai, Tadaaki; Muramatsu, Yasuyuki; Yoshida, Satoshi; Yanagisawa, Kei

    1996-01-01

    Radiotracer experiments were performed to study radionuclide uptake by mushrooms and plants. Four mushroom species, Hebeloma vinosophyllum, Flammulina velutipes, Agrocybe cylindracea and Coprinus phlyctidosporus were cultivated in a flask containing medium with the radiotracers 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn. Mushrooms tended to accumulate Cs, Mn and Zn. The concentration ratio of Cs between mushroom and medium ranged from 2.6 to 21. The highest was observed in H. vinospohyllum. The concentration ratio of Mn was about 10, while the ratio of Zn ranged from 15 to 30. No noticeable accumulations were found for Sr or Co. Transfer factors (TFs) of radionuclides from soil to leaf vegetables (cabbage, Chinese cabbage, komatsuna, spinach and lettuce) were also studied using Andosol (a representative Japanese soil). The TFs of 137 Cs, 85 Sr, 54 Mn, 60 Co and 65 Zn for edible parts of these vegetables were (mean value) 0.11, 0.24, 0.61, 0.05 and 0.52, respectively. The TFs of Mn, Co and Zn for spinach were higher than those for the other vegetables. The distributions of Cs in different organs of the leaf vegetables were rather uniform. The TFs of Sr and Mn were higher for older (outer) leaves than younger (inner) ones. In contrast to Sr and Mn, TFs of Zn for younger leaves were higher than those for older ones

  18. Strong gravitational lensing by a Konoplya-Zhidenko rotating non-Kerr compact object

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shangyun; Chen, Songbai; Jing, Jiliang, E-mail: shangyun_wang@163.com, E-mail: csb3752@hunnu.edu.cn, E-mail: jljing@hunnu.edu.cn [Institute of Physics and Department of Physics, Hunan Normal University, Changsha, Hunan 410081 (China)

    2016-11-01

    Konoplya and Zhidenko have proposed recently a rotating non-Kerr black hole metric beyond General Relativity and make an estimate for the possible deviations from the Kerr solution with the data of GW 150914. We here study the strong gravitational lensing in such a rotating non-Kerr spacetime with an extra deformation parameter. We find that the condition of existence of horizons is not inconsistent with that of the marginally circular photon orbit. Moreover, the deflection angle of the light ray near the weakly naked singularity covered by the marginally circular orbit diverges logarithmically in the strong-field limit. In the case of the completely naked singularity, the deflection angle near the singularity tends to a certain finite value, whose sign depends on the rotation parameter and the deformation parameter. These properties of strong gravitational lensing are different from those in the Johannsen-Psaltis rotating non-Kerr spacetime and in the Janis-Newman-Winicour spacetime. Modeling the supermassive central object of the Milk Way Galaxy as a Konoplya-Zhidenko rotating non-Kerr compact object, we estimated the numerical values of observables for the strong gravitational lensing including the time delay between two relativistic images.

  19. A six-week clinical evaluation of the plaque and gingivitis efficacy of an oscillating-rotating power toothbrush with a novel brush head utilizing angled CrissCross bristles versus a sonic toothbrush.

    Science.gov (United States)

    Klukowska, Malgorzata; Grender, Julie M; Conde, Erinn; Goyal, C Ram; Qaqish, J

    2014-01-01

    To compare the efficacy of an oscillating-rotating power toothbrush with a novel brush head incorporating angled CrissCross bristles (Oral-B Triumph with SmartGuide with Oral-B CrossAction brush head) versus a sonic toothbrush (Sonicare DiamondClean) for plaque and gingivitis reduction over a six-week period. This was a single-center, randomized, examiner-blind, two-treatment, parallel group study involving 65 subjects per group. Subjects presenting with mild-to-moderate gingivitis at Baseline were randomly assigned to either the oscillating-rotating brush or the sonic brush. They were instructed to use their assigned toothbrush and a standard fluoride dentifrice for two minutes twice daily at home for six weeks. Gingivitis and plaque were assessed at Baseline and Week 6 using the Modified Gingival Index (MGI), Gingival Bleeding Index (GBI), and Rustogi Modified Navy Plaque Index (RMNPI). Data were analyzed using an Analysis of Covariance (ANCOVA), with baseline as the covariate. Subjects also completed a consumer perception questionnaire to evaluate their brushing experience. One-hundred and thirty subjects were enrolled in the study and randomized to treatment. Sixty-four subjects per group completed the trial. Both brushes produced statistically significant reductions in gingivitis and plaque measures at Week 6 relative to Baseline (p gingivitis and plaque measures compared to the sonic toothbrush. The benefits for the oscillating-rotating brush over the sonic brush were 32.6% for gingivitis, 35.4% for gingival bleeding, 32% for number of bleeding sites, 22% for whole mouth plaque, 24.2% for gingival margin plaque, and 33.3% for approximal plaque (p gingival margin plaque, where p = 0.018). Analysis of the consumer perception questionnaire results showed subjects using the oscillating-rotating brush rated it higher for overall use experience and key attributes related to cleaning, gentleness, and brush head shape/size versus subjects in the sonic brush group

  20. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator

    International Nuclear Information System (INIS)

    Du, Weiliang; Gao, Song

    2011-01-01

    Purpose: The isocenter accuracy of a linear accelerator is often assessed with star-shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston-Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change. Methods: A stationary ball-bearing phantom was imaged using multileaf collimator-shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball-bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified. Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator. Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.

  1. Measuring the wobble of radiation field centers during gantry rotation and collimator movement on a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Du, Weiliang; Gao, Song [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, 77030 (United States)

    2011-08-15

    Purpose: The isocenter accuracy of a linear accelerator is often assessed with star-shot films. This approach is limited in its ability to quantify three dimensional wobble of radiation field centers (RFCs). The authors report a Winston-Lutz based method to measure the 3D wobble of RFCs during gantry rotation, collimator rotation, and collimator field size change. Methods: A stationary ball-bearing phantom was imaged using multileaf collimator-shaped radiation fields at various gantry angles, collimator angles, and field sizes. The center of the ball-bearing served as a reference point, to which all RFCs were localized using a computer algorithm with subpixel accuracy. Then, the gantry rotation isocenter and the collimator rotation axis were derived from the coordinates of these RFCs. Finally, the deviation or wobble of the individual RFC from the derived isocenter or rotation axis was quantified. Results: The results showed that the RFCs were stable as the field size of the multileaf collimator was varied. The wobble of RFCs depended on the gantry angle and the collimator angle and was reproducible, indicating that the mechanical imperfections of the linac were mostly systematic and quantifiable. It was found that the 3D wobble of RFCs during gantry rotation was reduced after compensating for a constant misalignment of the multileaf collimator. Conclusions: The 3D wobble of RFCs can be measured with submillimeter precision using the proposed method. This method provides a useful tool for checking and adjusting the radiation isocenter tightness of a linac.

  2. Polarization splitter and polarization rotator designs based on transformation optics.

    Science.gov (United States)

    Kwon, Do-Hoon; Werner, Douglas H

    2008-11-10

    The transformation optics technique is employed in this paper to design two optical devices - a two-dimensional polarization splitter and a three-dimensional polarization rotator for propagating beams. The polarization splitter translates the TM- and the TE-polarized components of an incident beam in opposite directions (i.e., shifted up or shifted down). The polarization rotator rotates the polarization state of an incoming beam by an arbitrary angle. Both optical devices are reflectionless at the entry and exit interfaces. Design details and full-wave simulation results are provided.

  3. NMR and rotational angles in solution conformation of polypeptides

    Science.gov (United States)

    Bystrov, V. F.

    1985-01-01

    Professor San-Ichiro Mizushima and Professor Yonezo Morino's classical contributions provided unique means and firm basis for understanding of conformational states and internal rotation in polypeptide molecules. Now the NMR spectroscopy is the best choice to study molecular conformation, mechanism of action and structure-functional relationships of peptide and proteins in solution under conditions approaching those of their physiological environments. Crucial details of spatial structure and interactions of these molecules in solution are revealed by using proton-proton and carbon-proton vicinal coupling constants, proton nuclear Overhauser effect and spectral perturbation techniques. The results of NMR conformational analysis are presented for valinomycin "bracelet", gramicidin A double helices, honey-bee neurotoxin apamin, scorpion insectotoxins and snake neurotoxins of long and short types.

  4. Radiotracer study in a bubble column reactor (visbreaker)

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Rohit Kulkarni; Pandit, A.B.; Kumar, M.M.; Berne, Ph.

    2004-01-01

    Radiotracer technique was used to measure residence time distribution (RTD) of fuel oil in a pilot-plant visbreaker with an objective to investigate hydrodynamic behaviour at different operating conditions. Bromine-82 as dibromobiphenyle was used as a tracer to measure RTD of the fuel oil. Mean residence times were determined from the measured RTD data. Tanks-in-series with backmixing model was used to simulate the measured RTD data. The results of simulation indicated that the visbreaker did not behave as a plug flow reactor as desired for visbreaking process. The presence of internals i.e. baffles inside the visbreaker decreases the mean residence time and backmixing. Thus, the designed internals have shown promising effect in terms of reduced backmixing in the visbreaker. (author)

  5. Effects of flow changes on radiotracer binding: Simultaneous measurement of neuroreceptor binding and cerebral blood flow modulation.

    Science.gov (United States)

    Sander, Christin Y; Mandeville, Joseph B; Wey, Hsiao-Ying; Catana, Ciprian; Hooker, Jacob M; Rosen, Bruce R

    2017-01-01

    The potential effects of changes in blood flow on the delivery and washout of radiotracers has been an ongoing question in PET bolus injection studies. This study provides practical insight into this topic by experimentally measuring cerebral blood flow (CBF) and neuroreceptor binding using simultaneous PET/MRI. Hypercapnic challenges (7% CO 2 ) were administered to non-human primates in order to induce controlled increases in CBF, measured with pseudo-continuous arterial spin labeling. Simultaneously, dopamine D 2 /D 3 receptor binding of [ 11 C]raclopride or [ 18 F]fallypride was monitored with dynamic PET. Experiments showed that neither time activity curves nor quantification of binding through binding potentials ( BP ND ) were measurably affected by CBF increases, which were larger than two-fold. Simulations of experimental procedures showed that even large changes in CBF should have little effect on the time activity curves of radiotracers, given a set of realistic assumptions. The proposed method can be applied to experimentally assess the flow sensitivity of other radiotracers. Results demonstrate that CBF changes, which often occur due to behavioral tasks or pharmacological challenges, do not affect PET [ 11 C]raclopride or [ 18 F]fallypride binding studies and their quantification. The results from this study suggest flow effects may have limited impact on many PET neuroreceptor tracers with similar properties.

  6. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique

    International Nuclear Information System (INIS)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J.; Biswal, Jayashree; Sharma, Vijay K.; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K.; Rao, S. Madhukar; Dash, A.

    2016-01-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. - Highlights: • Radiotracer experiments were conducted to measure RTD of liquid phase in a pulp digester • Mean residence times of white liquor were measured • Axial dispersion and tanks-in-series models were used to investigate flow patterns • Parallel flow paths were observed in first section of the digester • Optimized flow rates of biomass and liquor were obtained

  7. A conjunct near-surface spectroscopy system for fix-angle and multi-angle continuous measurements of canopy reflectance and sun-induced chlorophyll fluorescence

    Science.gov (United States)

    Zhang, Qian; Fan, Yifeng; Zhang, Yongguang; Chou, Shuren; Ju, Weimin; Chen, Jing M.

    2016-09-01

    An automated spectroscopy system, which is divided into fix-angle and multi-angle subsystems, for collecting simultaneous, continuous and long-term measurements of canopy hyper-spectra in a crop ecosystem is developed. The fix-angle subsystem equips two spectrometers: one is HR2000+ (OceanOptics) covering the spectral range 200-1100 nm with 1.0 nm spectral resolution, and another one is QE65PRO (OceanOptics) providing 0.1 nm spectral resolution within the 730-780 nm spectral range. Both spectrometers connect a cosine-corrected fiber-optic fixed up-looking to collect the down-welling irradiance and a bare fiber-optic to measure the up-welling radiance from the vegetation. An inline fiber-optic shutter FOS-2x2-TTL (OceanOptics) is used to switch between input fibers to collect the signal from either the canopy or sky at one time. QE65PRO is used to permit estimation of vegetation Sun-Induced Fluorescence (SIF) in the O2-A band. The data collection scheme includes optimization of spectrometer integration time to maximize the signal to noise ratio and measurement of instrument dark currency. The multi-angle subsystem, which can help understanding bidirectional reflectance effects, alternatively use HR4000 (OceanOptics) providing 0.1 nm spectral resolution within the 680-800 nm spectral range to measure multi-angle SIF. This subsystem additionally includes a spectrometer Unispec-DC (PPSystems) featuring both up-welling and down-welling channels with 3 nm spectral resolution covering the 300-1100 nm spectral range. Two down-looking fiber-optics are mounted on a rotating device PTU-D46 (FLIR Systems), which can rotate horizontally and vertically at 10° angular step widths. Observations can be used to calculate canopy reflectance, vegetation indices and SIF for monitoring plant physiological processes.

  8. Femoral component rotation in patellofemoral joint replacement.

    Science.gov (United States)

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Misalignment calibration of geomagnetic vector measurement system using parallelepiped frame rotation method

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Zhu, XueJun; Pan, Mengchun; Zhang, Qi; Wan, Chengbiao; Luo, Shitu; Chen, Dixiang; Chen, Jinfei; Li, Ji; Lv, Yunxiao

    2016-01-01

    Misalignment error is one key factor influencing the measurement accuracy of geomagnetic vector measurement system, which should be calibrated with the difficulties that sensors measure different physical information and coordinates are invisible. A new misalignment calibration method by rotating a parallelepiped frame is proposed. Simulation and experiment result show the effectiveness of calibration method. The experimental system mainly contains DM-050 three-axis fluxgate magnetometer, INS (inertia navigation system), aluminium parallelepiped frame, aluminium plane base. Misalignment angles are calculated by measured data of magnetometer and INS after rotating the aluminium parallelepiped frame on aluminium plane base. After calibration, RMS error of geomagnetic north, vertical and east are reduced from 349.441 nT, 392.530 nT and 562.316 nT to 40.130 nT, 91.586 nT and 141.989 nT respectively. - Highlights: • A new misalignment calibration method by rotating a parallelepiped frame is proposed. • It does not need to know sensor attitude information or local dip angle. • The calibration system attitude change angle is not strictly required. • It can be widely used when sensors measure different physical information. • Geomagnetic vector measurement error is reduced evidently.

  10. Misalignment calibration of geomagnetic vector measurement system using parallelepiped frame rotation method

    Energy Technology Data Exchange (ETDEWEB)

    Pang, Hongfeng [Academy of Equipment, Beijing 101416 (China); College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073 (China); Zhu, XueJun, E-mail: zhuxuejun1990@126.com [College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073 (China); Pan, Mengchun; Zhang, Qi; Wan, Chengbiao; Luo, Shitu; Chen, Dixiang; Chen, Jinfei; Li, Ji; Lv, Yunxiao [College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073 (China)

    2016-12-01

    Misalignment error is one key factor influencing the measurement accuracy of geomagnetic vector measurement system, which should be calibrated with the difficulties that sensors measure different physical information and coordinates are invisible. A new misalignment calibration method by rotating a parallelepiped frame is proposed. Simulation and experiment result show the effectiveness of calibration method. The experimental system mainly contains DM-050 three-axis fluxgate magnetometer, INS (inertia navigation system), aluminium parallelepiped frame, aluminium plane base. Misalignment angles are calculated by measured data of magnetometer and INS after rotating the aluminium parallelepiped frame on aluminium plane base. After calibration, RMS error of geomagnetic north, vertical and east are reduced from 349.441 nT, 392.530 nT and 562.316 nT to 40.130 nT, 91.586 nT and 141.989 nT respectively. - Highlights: • A new misalignment calibration method by rotating a parallelepiped frame is proposed. • It does not need to know sensor attitude information or local dip angle. • The calibration system attitude change angle is not strictly required. • It can be widely used when sensors measure different physical information. • Geomagnetic vector measurement error is reduced evidently.

  11. WE-EF-207-02: The Rotate-Plus-Shift C-Arm Trajectory: Theory and First Clinical Results

    International Nuclear Information System (INIS)

    Ritschl, L; Kachelriess, M; Kuntz, J

    2015-01-01

    Purpose: The proposed method enables the acquisition of a complete dataset for 3D reconstruction of C-Arm data using less than 180° rotation. Methods: Typically a C–arm cone–beam CT scan is performed using a circle–like trajectory around a region of interest. Therefore an angular range of at least 180° plus fan–angle must be covered to ensure a completely sampled data set. This fact defines some constraints on the geometry and technical specifications of a C–arm system, for example a larger C radius or a smaller C opening respectively. This is even more important for mobile C-arm devices which are typically used in surgical applications.To overcome these limitations we propose a new trajectory which requires only 180° minusfan–angle of rotation for a complete data set. The trajectory consists of three parts: A rotation of the C around a defined iso–center and two translational movements parallel to the detector plane at the begin and at the end of the rotation (rotate plus shift trajectory). This enables the acquisition of a completely sampled dataset using only 180° minus fan–angle of rotation. Results: For the evaluation of the method we show simulated and measured data. The results show, that the rotate plus shift scan yields equivalent image quality compared to the short scan which is assumed to be the gold standard for C-arm CT today. Compared to the pure rotational scan over only 165°, the rotate plus shift scan shows strong improvements in image quality. Conclusion: The proposed method makes 3D imaging using C–arms with less than 180° rotation range possible. This enables integrating full 3D functionality into a C- arm device without any loss of handling and usability for 2D imaging

  12. Multihelix rotating shield brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Dadkhah, Hossein [Department of Biomedical Engineering, University of Iowa, 1402 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States); Kim, Yusung; Flynn, Ryan T., E-mail: ryan-flynn@uiowa.edu [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Wu, Xiaodong [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 and Department of Electrical and Computer Engineering, University of Iowa, 4016 Seamans Center for the Engineering Arts and Sciences, Iowa City, Iowa 52242 (United States)

    2015-11-15

    Purpose: To present a novel brachytherapy technique, called multihelix rotating shield brachytherapy (H-RSBT), for the precise angular and linear positioning of a partial shield in a curved applicator. H-RSBT mechanically enables the dose delivery using only linear translational motion of the radiation source/shield combination. The previously proposed approach of serial rotating shield brachytherapy (S-RSBT), in which the partial shield is rotated to several angular positions at each source dwell position [W. Yang et al., “Rotating-shield brachytherapy for cervical cancer,” Phys. Med. Biol. 58, 3931–3941 (2013)], is mechanically challenging to implement in a curved applicator, and H-RSBT is proposed as a feasible solution. Methods: A Henschke-type applicator, designed for an electronic brachytherapy source (Xoft Axxent™) and a 0.5 mm thick tungsten partial shield with 180° or 45° azimuthal emission angles and 116° asymmetric zenith angle, is proposed. The interior wall of the applicator contains six evenly spaced helical keyways that rigidly define the emission direction of the partial radiation shield as a function of depth in the applicator. The shield contains three uniformly distributed protruding keys on its exterior wall and is attached to the source such that it rotates freely, thus longitudinal translational motion of the source is transferred to rotational motion of the shield. S-RSBT and H-RSBT treatment plans with 180° and 45° azimuthal emission angles were generated for five cervical cancer patients with a diverse range of high-risk target volume (HR-CTV) shapes and applicator positions. For each patient, the total number of emission angles was held nearly constant for S-RSBT and H-RSBT by using dwell positions separated by 5 and 1.7 mm, respectively, and emission directions separated by 22.5° and 60°, respectively. Treatment delivery time and tumor coverage (D{sub 90} of HR-CTV) were the two metrics used as the basis for evaluation and

  13. Supracondylar corrective osteotomy for cubitus varus--the internal rotation component and its importance. An unique bone experiment.

    Directory of Open Access Journals (Sweden)

    Jimulia T

    1994-10-01

    Full Text Available In 20 patients with cubitus varus, a clinical test suggested by Yamamoto et al (1985 was carried out to measure the internal rotation. Average internal rotation was found to be 37.5 +/- 9.390. A correction for internal rotation was carried out for all the patients having angle more than 20 degrees. Following osteotomy, post-operative Yamamoto′s angle was measured and was found to be 8.85 +/- 6.5. An experiment was carried out on postmortem human humerus with cubitus varus. The internal rotation was measured with Kirschner wires and was found to be 30 degrees. Osteotomy was carried out to eliminate varus and correct internal rotation. Radiographs taken before and after the osteotomy confirmed the correction. We conclude that this derotation has to be corrected and Yamamoto′s test should be used to assess the correction.

  14. Evaluation of radiotracers for the detection of atherosclerotic vulnerable plaque and myocardial angiogenesis

    International Nuclear Information System (INIS)

    Dimastromatteo, Julien

    2010-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide. Coronary events are mainly caused by coronary plaque rupture or erosion. However, at present, there is no noninvasive tool available for the detection of vulnerable plaques. The first part of thesis is about evaluation of new radiotracers for the detection of atherosclerotic vulnerable plaques. 99m Tc-B2702p, 20 derivatives, 99m Tc-VP and 99m Tc-VINP28 were evaluated in an experimental model of atherosclerosis (ApoE-/- mice with left carotid artery ligation). 99m Tc- B2702p1 is a potentially useful radiotracer for the in vivo molecular imaging of VCAM-1 expression in atherosclerotic plaques. Myocardial angiogenesis is an important post infarction phenomenon. Angiogenic therapy improves experimentally cardiac parameters. However, clinical trials using the same therapy are more controversial. At present, clinical imaging tools don't allow us to assess angiogenesis therapy. The second part of thesis is about validation of 99m Tc-RAFT-RGD in the detection of myocardial angiogenesis. 99m Tc-RAFT-RGD allow us to perform noninvasive molecular imaging of myocardial angiogenesis in an experimental model. (author)

  15. Characterization of a radiotracer-based 3-hydroxy-1-methyl peridine by its analogue Rhene

    International Nuclear Information System (INIS)

    Zitouni, Zeineb

    2010-01-01

    Since the discovery of artificial radioactivity in 1934, nuclear doctors have a variety of radioactive isotopes as indicators and markers. With these radioactive isotopes, it is possible to trace an atom or a chemical species without disrupting the physical behavior, chemical or biological. The branch of medicine and medical specialty now devoted to the use of radioactive elements for examination or treatment of patients, particularly the brain. Having a close relationship with radiobiology, radiation protection and Radiopharmacy, Nuclear Medicine Specialist is empowered to handle potentially dangerous isotope, observing precautions and regulations designed to reduce their risks. These radionuclides are used for exploration of cell kinetics, pharmacokinetics or for scans. Activities under this project led to the synthesis of N-methylferrocene, its characterization and its labeling with technetium 99 m. For the characterization of the radiotracer synthesized, we used to study the properties of complex similar models, labeled with rhenium. To verify and confirm this work, we propose the following perspectives: - Confirm the structure of N-methyl rhenium by nuclear magnetic resonance and single crystal X ray crystallography. - Develop and characterize new radiotracers brain.

  16. Biplanar variable angle x-ray examining apparatus

    International Nuclear Information System (INIS)

    Grady, J.K.

    1986-01-01

    This invention relates to radiological equipment, particularly to apparatus for supporting and maneuvering a plurality of radiological examination sets to permit simultaneous or sequential exposure through different planes of an organ. The apparatus comprises: a first radiological examining set including a radiation source, receptor, and support for holding the source and receptor along an axis; and a second examining set with the source and receptor aligned to intersect the first axis at a common isocenter. The first support means is rotatable independently of the second support means about a rotational axis intersecting the common isocenter. The support means for one radiological examining set comprises two arms respectively carrying the radiation source and the radiation receptor of the one set and means reciprocally supporting the respective arms for movement independently of each other parallel to the rotational axis, whereby a series of substantially simultaneous radiological examinations can be made on both radiation axes through the subject at variable angles between the axes

  17. Pros and cons of rotating ground motion records to fault-normal/parallel directions for response history analysis of buildings

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2014-01-01

    According to the regulatory building codes in the United States (e.g., 2010 California Building Code), at least two horizontal ground motion components are required for three-dimensional (3D) response history analysis (RHA) of building structures. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHAs should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here, for the first time, using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak values of engineering demand parameters (EDPs) were computed for rotation angles ranging from 0 through 180° to quantify the difference between peak values of EDPs over all rotation angles and those due to FN/FP direction rotated motions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

  18. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.

    2012-11-01

    In desert sunny clear-sky regions solar penetration can become excessive. This can cause non-uniform daylight distribution, glare and high solar heat gain, affecting both visual and thermal comfort. Shading devices, such as solar screens, were usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space under the desert sunny clear-sky. The larger aim is to arrive at efficient solar screen designs that suit the different orientations.The study was divided into three consecutive phases. In phase one, the effect of the two parameters on Daylight Availability was tested. The solar screen was axially rotated by three different angles at 10° increments. Also, the aspect ratio of the screen opening in both horizontal and vertical directions was changed systematically. Simulation was conducted using the annual Daylight Dynamic Performance Metrics (DDPMs). In phase two, the Annual Daylight Glare Probability (DGP) metric was evaluated for the cases that were found adequate in phase one. In the third phase, the annual solar energy transmittance through the screen was calculated for the cases that achieved acceptable performance in the two previous phases in order to identify the more energy efficient screens.Solar screens with openings having horizontal aspect ratios were found to be the most effective, while those with vertical aspect ratios were achieved the lowest performance. In the North orientation, since almost all the cases that were tested in this research provided acceptable daylighting performance, the designer now have a variety of options to choose from. Preference should be given to screen openings of horizontal aspect ratios, especially the 12:1 and 18:1 (H:V) screens that achieved the best performance where 92% of the space was " daylit" in comparison with only 53

  19. Determination of Pole and Rotation Period of not Stabilized Artificial Satellite by Use of Model "diffuse Cylinder"

    Science.gov (United States)

    Kolesnik, S. Ya.; Dobrovolsky, A. V.; Paltsev, N. G.

    The algorithm of determination of orientation of rotation axis (pole) and rotation period of satellite, simulated by a cylinder, which is precessing around of vector of angular moment of pulse with constant nutation angle is offered. The Lambert's law of light reflection is accepted. Simultaneously, dependence of light reflection coefficient versus phase angle is determined. The model's simulation confirm applicability of this method. Results of the calculations for artificial satellite No 28506 are carried out.

  20. Determination of retention period of sewage in a filtration plant using radiotracer technique

    International Nuclear Information System (INIS)

    Eapen, A.C.; Jain, S.K.; Kirti

    1979-01-01

    A radiotracer investigation was carried out at Dadar sewage purification plant, Bombay, for measuring the retention period of a trickling filter unit. The method is based on the addition of 82 Br tracer in the form of NH 4 Br solution at the inlet and continuous recording of the tracer at the flow stream. Results obtained in the actual investigation are also given. (auth.)

  1. A radiotracer technique for testing a high pressure gas compressor for oil leakage

    International Nuclear Information System (INIS)

    Eapen, A.C.; Kirti; Jain, S.K.; Gupta, P.P.

    1979-01-01

    The radiotracer investigations carried out at NOCIL, Bombay, to measure the amount of lubrication oil present in the gas being compressed in a 1000 H.P. centrifugal compressor are described. By injecting a few mCi 131 I labelled glyceryl trioleate tracer and monitoring the radioactivity of the outlet gas for about 20 hours, the extent of the oil present in the gas could be determined. (auth.)

  2. Radiotracer laboratory for agricultural research at the Malaysian Nuclear Agency

    International Nuclear Information System (INIS)

    Nashriyah Mat; Misman Sumin; Maizatul Akmam Mhd Nasir

    2007-01-01

    Radiotracer Laboratory for agricultural research at the Malaysian Nuclear Agency was established since 1990. It accommodates three laboratories, three chemical temporary storage compartments plus one compartment for storage of pressurized gas. This facility is situated in ground floor of Block 44, Agrotechnology and Biosciences Division, Dengkil Complex. Currently it houses a liquid scintillation counter, sample oxidizer, gas liquid chromatography, high performance liquid chromatography and auxiliary equipments. A road map for this laboratory will be discussed in relation with present scenario i.e. R and D service, training and consultancy provided by this laboratory; and future requirements and direction. (Author)

  3. A self-calibration method in single-axis rotational inertial navigation system with rotating mechanism

    Science.gov (United States)

    Chen, Yuanpei; Wang, Lingcao; Li, Kui

    2017-10-01

    Rotary inertial navigation modulation mechanism can greatly improve the inertial navigation system (INS) accuracy through the rotation. Based on the single-axis rotational inertial navigation system (RINS), a self-calibration method is put forward. The whole system is applied with the rotation modulation technique so that whole inertial measurement unit (IMU) of system can rotate around the motor shaft without any external input. In the process of modulation, some important errors can be decoupled. Coupled with the initial position information and attitude information of the system as the reference, the velocity errors and attitude errors in the rotation are used as measurement to perform Kalman filtering to estimate part of important errors of the system after which the errors can be compensated into the system. The simulation results show that the method can complete the self-calibration of the single-axis RINS in 15 minutes and estimate gyro drifts of three-axis, the installation error angle of the IMU and the scale factor error of the gyro on z-axis. The calibration accuracy of optic gyro drifts could be about 0.003°/h (1σ) as well as the scale factor error could be about 1 parts per million (1σ). The errors estimate reaches the system requirements which can effectively improve the longtime navigation accuracy of the vehicle or the boat.

  4. Rotation curve of our galaxy; how well do we know it

    Energy Technology Data Exchange (ETDEWEB)

    Pismis, P [Universidad Nacional Autonoma de Mexico, Mexico City. Inst. de Astronomia

    1981-01-01

    Following an historical sketch of the relevant circumstances leading to the formulation of the rotation of the galaxy, the differential rotation formulae are recalled. The necessity of obtaining an overall rotation curve at the advent of radioastronomy is stressed; only through the knowledge of such a curve can the kinematic distances of H I profiles, H II regions and molecular clouds be obtained. The existence of the deviations from a smooth rotation curve are pointed out; in particular it is shown that the curve exhibits ''waves'', a phenomenon at present known to be rather common in spiral galaxies. Maxima and minima correspond to arm and interarm regions, respectively. The interpretation of these waves as population effects suggested earlier by this author is emphasized once again. Recent observations of H II regions and CO clouds suggest that the sun is located close to the minimum of a wave. Another irregularity, the presumed difference in the north and south rotation curves, is also briefly discussed. Based on a plausible assumption that the spiral structure can be represented by a pair of symmetrically located logarithmic spirals, it is shown that if waves do indeed exist - irrespective of the cause of such waves - the rotation curve in our galaxy and in others will be a function of direction from the galactic center. Unlike external galaxies, from the location of the sun we are not able to obtain the rotation velocity in all directions. An average rotation curve where the waves are smoothed out can be obtained from the mean over directions within a central angle of 180/sup 0/. However, from our eccentric position in the galaxy we can obtain information on the rotation law at best within a central angle of 120/sup 0/. Finally, it is emphazied that the rotation curve discussed usually is that of the fastest rotating system, the population I, which contains not more than 10% of the total mass of the galaxy. The rotation curve is, therefore, not unique.

  5. Radiotracer investigation of the cold-vapour atomic absorption method of analysis for trace mercury

    International Nuclear Information System (INIS)

    Stuart, D.C.

    1978-01-01

    Because of certain problems found in application of the atomic absorption method for trace analysis of mercury, a careful check of the procedures used was undertaken, with radiotracer mercury to facilitate the investigation. The results obtained, in conjunction with those of sample ashing procedures, indicate that the method is less straightforward than its simplicity suggests. (Auth.)

  6. Development of [11C]-α-aminoisobutyric acid and [18F]-haloperidol as substrate-specific radiotracers

    International Nuclear Information System (INIS)

    Zanzonico, P.B.

    1982-01-01

    In light of the emergence of positron emission tomography (PET), two new substrate-specific radiotracers have been synthesized and evaluated as potential agents for the study of specific physiological processes: [1- 11 C]-α-aminoisobutyric acid ([1- 11 C]-AIB), a transport system-specific radiotracer for tumor localization and for the assessment of amino acid transport in vivo; and [ 18 F]-haloperidoll, a receptor-binding radiotracer for the assessment of brain dopamine receptors in vivo. AIB, a non-metabolized amino acid, accumulates in cells, particularly malignant cells, via the A type, or ''alanine-preferring'', amino acid transport system [1- 11 C]-AIB in normal and in treated and untreated tumor-bearing rats, in tumor-bearing dogs, and in a tumor-bearing patient indicate rapid blood clearance and, concomitantly, rapid tissue localization, with slow net redistribution. Generally, there was selective localization in the kidney, in the liver, and in the pancreas, as well as in various tumors. The canine tumors and the human tumor were well visualized by external scintigraphy, especially when utilizing PET. [ 18 F]-Haloperidol, a dopamine receptor-binding neuroleptic of the butyrophenone series widely used in the management of schizophrenia was prepared via the Balz-Schiemann reaction. As the haloperdol dose administered to mice was increased from 0.01 to 1000 μg/kg, the relative concentration (μCi found per gm tisue sample/μCi injected per gm body mass) of [ 18 F]-haloperidol at 1 hr decreased from 30 to 1.0 in the striatum and from 8.0 to 1.0 in the cerebellum. The decrease in striatum radioactivity reflects competition between labeled and unlabeled haloperidol for dopamine receptors

  7. A Microscopic Quantal Model for Nuclear Collective Rotation

    International Nuclear Information System (INIS)

    Gulshani, P.

    2007-01-01

    A microscopic, quantal model to describe nuclear collective rotation in two dimensions is derived from the many-nucleon Schrodinger equation. The Schrodinger equation is transformed to a body-fixed frame to decompose the Hamiltonian into a sum of intrinsic and rotational components plus a Coriolis-centrifugal coupling term. This Hamiltonian (H) is expressed in terms of space-fixed-frame particle coordinates and momenta by using commutator of H with a rotation angle. A unified-rotational-model type wavefunction is used to obtain an intrinsic Schrodinger equation in terms of angular momentum quantum number and two-body operators. A Hartree-Fock mean-field representation of this equation is then obtained and, by means of a unitary transformation, is reduced to a form resembling that of the conventional semi-classical cranking model when exchange terms and intrinsic spurious collective excitation are ignored

  8. Comparison of two peptide radiotracers for prostate carcinoma targeting

    Directory of Open Access Journals (Sweden)

    Bluma Linkowski Faintuch

    2012-01-01

    Full Text Available OBJECTIVES: Scintigraphy is generally not the first choice treatment for prostate cancer, although successful studies using bombesin analog radiopeptides have been performed. Recently, a novel peptide obtained using a phage display library demonstrated an affinity for prostate tumor cells. The aim of this study was to compare the use of a bombesin analog to that of a phage display library peptide (DUP-1 radiolabeled with technetium-99m for the treatment of prostate carcinoma. The peptides were first conjugated to S-acetyl-MAG3 with a 6-carbon spacer, namely aminohexanoic acid. METHODS: The technetium-99m labeling required a sodium tartrate buffer. Radiochemical evaluation was performed using ITLC and was confirmed by high-performance liquid chromatography. The coefficient partition was determined, and in vitro studies were performed using human prostate tumor cells. Biodistribution was evaluated in healthy animals at various time points and also in mice bearing tumors. RESULTS: The radiochemical purity of both radiotracers was greater than 95%. The DUP-1 tracer was more hydrophilic (log P = -2.41 than the bombesin tracer (log P = -0.39. The biodistribution evaluation confirmed this hydrophilicity by revealing the greater kidney uptake of DUP-1. The bombesin concentration in the pancreas was greater than that of DUP-1 due to specific gastrin-releasing peptide receptors. Bombesin internalization occurred for 78.32% of the total binding in tumor cells. The DUP-1 tracer showed very low binding to tumor cells during the in vitro evaluation, although tumor uptake for both tracers was similar. The tumors were primarily blocked by DUP1 and the bombesin radiotracer primarily targeted the pancreas. CONCLUSION: Further studies with the radiolabeled DUP-1 peptide are recommended. With further structural changes, this molecule could become an efficient alternative tracer for prostate tumor diagnosis.

  9. SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

    Energy Technology Data Exchange (ETDEWEB)

    Ju, S; Hong, C; Kim, M; Chung, K; Kim, J; Han, Y; Ahn, S; Chung, S; Shin, E; Shin, J; Kim, H; Kim, D; Choi, D [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

  10. Broken symmetries and the Cabibbo angle

    International Nuclear Information System (INIS)

    Lanik, J.

    1975-04-01

    Under the assumption that the SU(3) symmetry is broken down by the strong and electromagnetic interactions, a phenomenological theory of the Cabibbo angle theta is proposed. In this theory the angle theta is fixed, linking together the Cabibbo rotation in the SU(3) space and complete SU(3) breaking consisting of both the SU(3) Hamiltonian and vacuum non-invariances. Assuming that the value of theta is zero in the soft-pion limit and that, in this limit, the only forces responsible for the isotopic symmetry breaking are the usual photonic forces it is shown that the usual electromagnetic interactions can contribute for the value of theta only through the non-vanishing vacuum expectation value of a certain scalar field. Within the framework of the (3,average3)+(3,average3) chiral symmetry-breaking model and through the use of the experimental value of the ratio GAMMA (K→μν)/GAMMA(π→μν), the presented Cabibbo angle theory predicts the value sintheta=0.25 which is in good agreement with experiment. (Lanik, J.)

  11. Measurement of instantaneous rotational speed using double-sine-varying-density fringe pattern

    Science.gov (United States)

    Zhong, Jianfeng; Zhong, Shuncong; Zhang, Qiukun; Peng, Zhike

    2018-03-01

    Fast and accurate rotational speed measurement is required both for condition monitoring and faults diagnose of rotating machineries. A vision- and fringe pattern-based rotational speed measurement system was proposed to measure the instantaneous rotational speed (IRS) with high accuracy and reliability. A special double-sine-varying-density fringe pattern (DSVD-FP) was designed and pasted around the shaft surface completely and worked as primary angular sensor. The rotational angle could be correctly obtained from the left and right fringe period densities (FPDs) of the DSVD-FP image sequence recorded by a high-speed camera. The instantaneous angular speed (IAS) between two adjacent frames could be calculated from the real-time rotational angle curves, thus, the IRS also could be obtained accurately and efficiently. Both the measurement principle and system design of the novel method have been presented. The influence factors on the sensing characteristics and measurement accuracy of the novel system, including the spectral centrobaric correction method (SCCM) on the FPD calculation, the noise sources introduce by the image sensor, the exposure time and the vibration of the shaft, were investigated through simulations and experiments. The sampling rate of the high speed camera could be up to 5000 Hz, thus, the measurement becomes very fast and the change in rotational speed was sensed within 0.2 ms. The experimental results for different IRS measurements and characterization of the response property of a servo motor demonstrated the high accuracy and fast measurement of the proposed technique, making it attractive for condition monitoring and faults diagnosis of rotating machineries.

  12. Optimal Full Waveform Inversion Strategy in Azimuthally Rotated Elastic Orthorhombic Media

    KAUST Repository

    Oh, Juwon

    2017-05-26

    The elastic orthorhombic assumption is one of the most practical Earth models that takes into account the horizontal anisotropic layering and vertical fracture network. In this model, the rotation angle of the vertical planes of symmetry is a crucial parameter needed to increase the convergence of an anisotropic full waveform inversion (FWI) as well as to provide the fracture geometry along azimuthal direction. As an initial step, we investigate the possibility of recovering the azimuth angle via FWI, which may offer high-resolution information. We first utilize our new parameterization with deviation parameters, which provides the opportunity for multi-stage FWI. Based on the radiation patterns and gradient directions of each parameter, we show that the azimuth angle mainly affects the parameters that have azimuth-dependent radiation patterns, so that we can hierarchically build up the subsurface model from isotropic to VTI to azimuthally rotated orthorhombic models with less trade-offs. From the numerical example for a synthetic 3D model, we expect that both a deviation parameter and the azimuth angle can be recovered in the last stage of FWI with minimum trade-offs.

  13. Kinematic relationship between rotation of lumbar spine and hip joints during golf swing in professional golfers.

    Science.gov (United States)

    Mun, Frederick; Suh, Seung Woo; Park, Hyun-Joon; Choi, Ahnryul

    2015-05-14

    Understanding the kinematics of the lumbar spine and hip joints during a golf swing is a basic step for identifying swing-specific factors associated with low back pain. The objective of this study was to examine the kinematic relationship between rotational movement of the lumbar spine and hip joints during a golf swing. Fifteen professional golfers participated in this study with employment of six infrared cameras to record their golf swings. Anatomical reference system of the upper torso, pelvis and thigh segments, and the location of each hip and knee joint were defined by the protocols of the kinematic model of previous studies. Lumbar spine and hip joint rotational angle was calculated utilizing the Euler angle method. Cross-correlation and angle-angle plot was used to examine the degree of kinematic relationship between joints. A fairly strong coupling relationship was shown between the lumbar spine and hip rotational movements with an average correlation of 0.81. Leading hip contribution to overall rotation was markedly high in the early stage of the downswing, while the lumbar spine contributed greater towards the end of the downswing; however, the relative contributions of the trailing hip and lumbar spine were nearly equal during the entire downswing. Most of the professional golfers participated in this study used a similar coordination strategy when moving their hips and lumbar spine during golf swings. The rotation of hips was observed to be more efficient in producing the overall rotation during the downswing when compared to the backswing. These results provide quantitative information to better understand the lumbar spine and hip joint kinematic characteristics of professional golfers. This study will have great potential to be used as a normal control data for the comparison with kinematic information among golfers with low back pain and for further investigation of golf swing-specific factors associated with injury.

  14. Determination of oil reservoir radiotracer (S{sup 14}CN{sup -}) in a single step using a plastic scintillator extractive resin

    Energy Technology Data Exchange (ETDEWEB)

    Bagan, H.; Tarancon, A. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Stavsetra, L. [Department for Reservoir and Exploration Technology, Institute for Energy Technology (IFE), Instituttveien 18, N-2027 Kjeller (Norway); Rauret, G. [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain); Garcia, J.F., E-mail: jfgarcia@ub.edu [Departament de Quimica Analitica, Universitat de Barcelona, Diagonal 645, E-08028 Barcelona (Spain)

    2012-07-29

    Highlights: Black-Right-Pointing-Pointer A new procedure for S{sup 14}CN{sup -} radiotracer determination using PS resin was established. Black-Right-Pointing-Pointer The minimum detectable activity for a 100 mL sample is 0.08 Bq L{sup -1}. Black-Right-Pointing-Pointer The minimum quantifiable activity for a 100 mL sample is 0.31 Bq L{sup -1}. Black-Right-Pointing-Pointer PS resin is capable to quantify S{sup 14}CN{sup -} radiotracer samples with errors lower than 5%. Black-Right-Pointing-Pointer PS resin is also capable to quantify complex matrices obtained from oil reservoirs. - Abstract: The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S{sup 14}CN{sup -}. Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentration that may lead to problems with phase separation during the LS measurement. Plastic Scintillation (PS) is an alternative technique that provides a solid surface that can be used as a platform for the immobilisation of selective extractants to obtain a PS resin. The proposed procedure unifies chemical separation and sample measurement preparation in a single step, serving to reduce the number of reagents needed and manpower required for the analysis while also avoiding mixed waste production by LS. The objective of this study is to develop a PS resin for the determination of {sup 14}C-labelled thiocyanate radiotracer in water samples. For this purpose, the immobilisation procedure was optimised, including optimisation of the proportion of PS microspheres:extractant and the use of a control blank to monitor the PS resin immobilisation process. The breakthrough volume was studied and the detection and quantification limits for 100 mL of sample were determined to be 0.08 Bq L{sup -1

  15. Boundary Layer Transition Detection on a Rotor Blade Using Rotating Mirror Thermography

    Science.gov (United States)

    Heineck, James T.; Schuelein, Erich; Raffel, Markus

    2014-01-01

    Laminar-to-turbulent transition on a rotor blade in hover has been imaged using an area-scan infrared camera. A new method for tracking a blade using a rotating mirror was employed. The mirror axis of rotation roughly corresponded to the rotor axis of rotation and the mirror rotational frequency is 1/2 that of the rotor. This permitted the use of cameras whose integration time was too long to prevent image blur due to the motion of the blade. This article will show the use of this method for a rotor blade at different collective pitch angles.

  16. Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [18F]MNI-698

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Caillé, Fabien; Barret, Olivier; Papin, Caroline; Lee, Hsiaoju; Morley, Thomas J.; Fowles, Krista; Holden, Daniel; Seibyl, John P.; Alagille, David; Tamagnan, Gilles D.

    2014-01-01

    Introduction: A new radiotracer for imaging the serotonin 4 receptors (5-HT 4 ) in brain, [ 18 F]MNI-698, was recently developed by our group. Evaluation in nonhuman primates indicates the novel radiotracer holds promise as an imaging agent of 5-HT 4 in brain. This paper aims to describe the whole-body biodistribution and dosimetry estimates of [ 18 F]MNI-698. Methods: Whole-body positron emission tomography (PET) images were acquired over 240 minutes after intravenous bolus injection of [ 18 F]MNI-698 in adult rhesus monkeys. Different models were investigated for quantification of radiation absorbed and effective doses using OLINDA/EXM 1.0 software. Results: The radiotracer main elimination route was found to be urinary and the critical organ was the urinary bladder. Modeling of the urinary bladder voiding interval had a considerable effect on the estimated effective dose. Normalization of rhesus monkeys’ organs and whole-body masses to human equivalent reduced the calculated dosimetry values. The effective dose ranged between 0.017 and 0.027 mSv/MBq. Conclusion: The dosimetry estimates, obtained when normalizing organ and whole-body weights and applying the urinary bladder model, indicate that the radiation doses from [ 18 F]MNI-698 comply with limits and guidelines recommended by key regulatory authorities that govern the translation of radiotracers to human clinical trials. The timing of urinary bladder emptying should be considered when designing future clinical protocols with [ 18 F]MNI-698, in order to minimize the subject absorbed doses

  17. Non-destructive investigation of technical plants and processes and natural processes by short-lived radionuclides (radiotracer)

    International Nuclear Information System (INIS)

    Jentsch, Thorsten; Zeuner, Albert

    2009-01-01

    Short lived open radionuclides are very suitable to investigate transport and mixing processes. They do not pollute the product. After decay of the radionuclide, the product can be used without any restrictions. Examples are showed for technical processes investigation by aid of radiotracer. (orig.)

  18. Special aspects of the indirect radiotracer technique when used to study the adsorption and electrochemical reactions of organic substances at solid electrodes

    International Nuclear Information System (INIS)

    Andreev, V.N.; Horanyi, G.; Kazarinov, V.E.

    1986-01-01

    This paper analyzes the possibilities and special aspects of the indirect radiotracer technique with a number of examples. Data are presented concerning the effects of acetic and oxalic acid on chloride ion adsorption on platinized platinum electrodes at a potential E = 0.2 V. The effect on chloride ion adsorption is much larger in the case of oxalic acid, which is evidence for its higher adsorbability on platinum at E = 0.2 V. It is shown that the indirect radiotracer technique offers significant possibilities for studying the electrochemical properties of adsorption products of organic substances

  19. Angle gathers in wave-equation imaging for transversely isotropic media

    KAUST Repository

    Alkhalifah, Tariq Ali; Fomel, Sergey B.

    2010-01-01

    In recent years, wave-equation imaged data are often presented in common-image angle-domain gathers as a decomposition in the scattering angle at the reflector, which provide a natural access to analysing migration velocities and amplitudes. In the case of anisotropic media, the importance of angle gathers is enhanced by the need to properly estimate multiple anisotropic parameters for a proper representation of the medium. We extract angle gathers for each downward-continuation step from converting offset-frequency planes into angle-frequency planes simultaneously with applying the imaging condition in a transversely isotropic with a vertical symmetry axis (VTI) medium. The analytic equations, though cumbersome, are exact within the framework of the acoustic approximation. They are also easily programmable and show that angle gather mapping in the case of anisotropic media differs from its isotropic counterpart, with the difference depending mainly on the strength of anisotropy. Synthetic examples demonstrate the importance of including anisotropy in the angle gather generation as mapping of the energy is negatively altered otherwise. In the case of a titled axis of symmetry (TTI), the same VTI formulation is applicable but requires a rotation of the wavenumbers. © 2010 European Association of Geoscientists & Engineers.

  20. Angle gathers in wave-equation imaging for transversely isotropic media

    KAUST Repository

    Alkhalifah, Tariq Ali

    2010-11-12

    In recent years, wave-equation imaged data are often presented in common-image angle-domain gathers as a decomposition in the scattering angle at the reflector, which provide a natural access to analysing migration velocities and amplitudes. In the case of anisotropic media, the importance of angle gathers is enhanced by the need to properly estimate multiple anisotropic parameters for a proper representation of the medium. We extract angle gathers for each downward-continuation step from converting offset-frequency planes into angle-frequency planes simultaneously with applying the imaging condition in a transversely isotropic with a vertical symmetry axis (VTI) medium. The analytic equations, though cumbersome, are exact within the framework of the acoustic approximation. They are also easily programmable and show that angle gather mapping in the case of anisotropic media differs from its isotropic counterpart, with the difference depending mainly on the strength of anisotropy. Synthetic examples demonstrate the importance of including anisotropy in the angle gather generation as mapping of the energy is negatively altered otherwise. In the case of a titled axis of symmetry (TTI), the same VTI formulation is applicable but requires a rotation of the wavenumbers. © 2010 European Association of Geoscientists & Engineers.

  1. [11C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    International Nuclear Information System (INIS)

    Wilson, Alan A.; Garcia, Armando; Parkes, Jun; Houle, Sylvain; Tong, Junchao; Vasdev, Neil

    2011-01-01

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([ 11 C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [ 11 C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [ 11 C]CURB was irreversibly bound to FAAH. Conclusions

  2. Vacuum variable-angle far-infrared ellipsometer

    Science.gov (United States)

    Friš, Pavel; Dubroka, Adam

    2017-11-01

    We present the design and performance of a vacuum far-infrared (∼50-680 cm-1) ellipsometer with a rotating analyser. The system is based on a Fourier transform spectrometer, an in-house built ellipsometer chamber and a closed-cycle bolometer. The ellipsometer chamber is equipped with a computer controlled θ-2θ goniometer for automated measurements at various angles of incidence. We compare our measurements on SrTiO3 crystal with the results acquired above 300 cm-1 with a commercially available ellipsometer system. After the calibration of the angle of incidence and after taking into account the finite reflectivity of mirrors in the detector part we obtain a very good agreement between the data from the two instruments. The system can be supplemented with a closed-cycle He cryostat for measurements between 5 and 400 K.

  3. Tool Indicates Contact Angles In Bearing Raceways

    Science.gov (United States)

    Akian, Richard A.; Butner, Myles F.

    1995-01-01

    Tool devised for use in measuring contact angles between balls and races in previously operated ball bearings. Used on both inner and outer raceways of bearings having cross-sectional widths between approximately 0.5 and 2.0 in. Consists of integral protractor mounted in vertical plane on bracket equipped with leveling screws and circular level indicator. Protractor includes rotatable indicator needle and set of disks of various sizes to fit various raceway curvatures.

  4. [A new kinematics method of determing elbow rotation axis and evaluation of its feasibility].

    Science.gov (United States)

    Han, W; Song, J; Wang, G Z; Ding, H; Li, G S; Gong, M Q; Jiang, X Y; Wang, M Y

    2016-04-18

    To study a new positioning method of elbow external fixation rotation axis, and to evaluate its feasibility. Four normal adult volunteers and six Sawbone elbow models were brought into this experiment. The kinematic data of five elbow flexion were collected respectively by optical positioning system. The rotation axes of the elbow joints were fitted by the least square method. The kinematic data and fitting results were visually displayed. According to the fitting results, the average moving planes and rotation axes were calculated. Thus, the rotation axes of new kinematic methods were obtained. By using standard clinical methods, the entrance and exit points of rotation axes of six Sawbone elbow models were located under X-ray. And The kirschner wires were placed as the representatives of rotation axes using traditional positioning methods. Then, the entrance point deviation, the exit point deviation and the angle deviation of two kinds of located rotation axes were compared. As to the four volunteers, the indicators represented circular degree and coplanarity of elbow flexion movement trajectory of each volunteer were both about 1 mm. All the distance deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 3 mm. All the angle deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 5°. As to the six Sawbone models, the average entrance point deviations, the average exit point deviations and the average angle deviations of two different rotation axes determined by two kinds of located methods were respectively 1.697 2 mm, 1.838 3 mm and 1.321 7°. All the deviations were very small. They were all in an acceptable range of clinical practice. The values that represent circular degree and coplanarity of volunteer's elbow single curvature movement trajectory are very small. The result shows that the elbow single curvature movement can be regarded as the approximate fixed

  5. NMR of bicelles: orientation and mosaic spread of the liquid-crystal director under sample rotation

    International Nuclear Information System (INIS)

    Zandomeneghi, Giorgia; Tomaselli, Marco; Williamson, Philip T.F.; Meier, Beat H.

    2003-01-01

    Model-membrane systems composed of liquid-crystalline bicellar phases can be uniaxially oriented with respect to a magnetic field, thereby facilitating structural and dynamics studies of membrane-associated proteins. Here we quantitatively characterize a method that allows the manipulation of the direction of this uniaxial orientation. Bicelles formed from DMPC/DHPC are examined by 31 P NMR under variable-angle sample-spinning (VAS) conditions, confirming that the orientation of the liquid-crystalline director can be influenced by sample spinning. The director is perpendicular to the rotation axis when Θ (the angle between the sample-spinning axis and the magnetic field direction) is smaller than the magic angle, and is parallel to the rotation axis when Θ is larger than the magic angle. The new 31 P NMR VAS data presented are considerably more sensitive to the orientation of the bicelle than earlier 2 H studies and the analysis of the sideband pattern allows the determination of the orientation of the liquid-crystal director and its variation over the sample, i.e., the mosaic spread. Under VAS, the mosaic spread is small if Θ deviates significantly from the magic angle but becomes very large at the magic angle

  6. Investigation of leaching of an antifouling agent from marine paint formulations using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Gursharan Singh; Kalgutkar, D.B.; Patil, S.P.; Jayachandran, N.; Unni, V.K.P.

    2012-01-01

    A radiotracer technique was used to investigate the leaching of an antifouling agent from different marine paint formulations with an objective to select the best paint formulation for bulk production. The antifouling agent (Diuron) itself was labeled with carbon-14 (half-life: 5,730 years, β-energy: 156 keV) and used as a radiotracer. The different paint formulations added with radiolabeled Diuron were applied onto suitably selected substrates and measured for initial intensity of β-radiation using a Geiger-Muller detector connected to a ratemeter. The painted substrates were subjected to shower tests for a pre-decided time and subsequently measured for β-radiations. The comparison of intensity of β-radiations in substrates prior and post shower tests provides information about leaching of antifouling agent Diuron from the paint formulation. The high leaching percentage of antifouling agent Diuron post shower tests indicates non-suitability of paint formulation for marine and civil structures. However, low leaching rate of Diuron will make a paint formulation more efficient and suitable. Based on the results of investigation, a paint formulation with minimum leaching rate was identified and selected for bulk production by a paint company. (author)

  7. Automated PET Radiotracer Manufacture on the BG75 System and Imaging Validation Studies of [18F]fluoromisonidazole ([18F]FMISO).

    Science.gov (United States)

    Yuan, Hong; Frank, Jonathan E; Merrill, Joseph R; Hillesheim, Daniel A; Khachaturian, Mark H; Anzellotti, Atilio I

    2016-01-01

    The hypoxia PET tracer, 1-[18F]fluoro-3-(2-nitro-1Himidazol- 1-yl)-propan-2-ol ([18F]FMISO) is the first radiotracer developed for hypoxia PET imaging and has shown promising for cancer diagnosis and prognosis. However, access to [18F]FMISO radiotracer is limited due to the needed cyclotron and radiochemistry expertise. The study aimed to develop the automated production method on the [18F]FMISO radiotracer with the novel fully automated platform of the BG75 system and validate its usage on animal tumor models. [18F]FMISO was produced with the dose synthesis cartridge automatically on the BG75 system. Validation of [18F]FMISO hypoxia imaging functionality was conducted on two tumor mouse models (FaDu/U87 tumor). The distribution of [18F]FMISO within tumor was further validated by the standard hypoxia marker EF5. The average radiochemical purity was (99±1) % and the average pH was 5.5±0.2 with other quality attributes passing standard criteria (n=12). Overall biodistribution for [18F]FMISO in both tumor models was consistent with reported studies where bladder and large intestines presented highest activity at 90 min post injection. High spatial correlation was found between [18F]FMISO autoradiography and EF5 hypoxia staining, indicating high hypoxia specificity of [18MF]FMISO. This study shows that qualified [18F]FMISO can be efficiently produced on the BG75 system in an automated "dose-on-demand" mode using single dose disposable cards. The possibilities of having a low-cost, automated system manufacturing ([18F]Fluoride production + synthesis + QC) different radiotracers will greatly enhance the potential for PET technology to reach new geographical areas and underserved patient populations. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Effects of Huge Earthquakes on Earth Rotation and the length of Day

    Directory of Open Access Journals (Sweden)

    Changyi Xu

    2013-01-01

    Full Text Available We calculated the co-seismic Earth rotation changes for several typical great earthquakes since 1960 based on Dahlen¡¦s analytical expression of Earth inertia moment change, the excitation functions of polar motion and, variation in the length of a day (ΔLOD. Then, we derived a mathematical relation between polar motion and earthquake parameters, to prove that the amplitude of polar motion is independent of longitude. Because the analytical expression of Dahlen¡¦s theory is useful to theoretically estimate rotation changes by earthquakes having different seismic parameters, we show results for polar motion and ΔLOD for various types of earthquakes in a comprehensive manner. The modeled results show that the seismic effect on the Earth¡¦s rotation decreases gradually with increased latitude if other parameters are unchanged. The Earth¡¦s rotational change is symmetrical for a 45° dip angle and the maximum changes appear at the equator and poles. Earthquakes at a medium dip angle and low latitudes produce large rotation changes. As an example, we calculate the polar motion and ΔLOD caused by the 2011 Tohoku-Oki Earthquake using two different fault models. Results show that a fine slip fault model is useful to compute co-seismic Earth rotation change. The obtained results indicate Dahlen¡¦s method gives good approximations for computation of co-seismic rotation changes, but there are some differences if one considers detailed fault slip distributions. Finally we analyze and discuss the co-seismic Earth rotation change signal using GRACE data, showing that such a signal is hard to be detected at present, but it might be detected under some conditions. Numerical results of this study will serve as a good indicator to check if satellite observations such as GRACE can detect a seismic rotation change when a great earthquake occur.

  9. Experimental study on flow past a rotationally oscillating cylinder

    Science.gov (United States)

    Gao, Yang-yang; Yin, Chang-shan; Yang, Kang; Zhao, Xi-zeng; Tan, Soon Keat

    2017-08-01

    A series of experiments was carried out to study the flow behaviour behind a rotationally oscillating cylinder at a low Reynolds number (Re=300) placed in a recirculation water channel. A stepper motor was used to rotate the cylinder clockwise- and- counterclockwise about its longitudinal axis at selected frequencies. The particle image velocimetry (PIV) technique was used to capture the flow field behind a rotationally oscillating cylinder. Instantaneous and timeaveraged flow fields such as the vorticity contours, streamline topologies and velocity distributions were analyzed. The effects of four rotation angle and frequency ratios F r ( F r= f n/ f v, the ratio of the forcing frequency f n to the natural vortex shedding frequency f v) on the wake in the lee of a rotationally oscillating cylinder were also examined. The significant wake modification was observed when the cylinder undergoes clockwise-and-counterclockwise motion with amplitude of π, especially in the range of 0.6≤ F r≤1.0.

  10. Classical theory of rotational rainbow scattering from uncorrugated surfaces

    International Nuclear Information System (INIS)

    Khodorkovsky, Yuri; Averbukh, Ilya Sh; Pollak, Eli

    2010-01-01

    A classical perturbation theory is developed to study rotational rainbow scattering of molecules from uncorrugated frozen surfaces. Considering the interaction of the rigid rotor with the translational motion towards the surface to be weak allows for a perturbative treatment, in which the known zeroth order motion is that of a freely rotating molecule hitting a surface. Using perturbation theory leads to explicit expressions for the angular momentum deflection function with respect to the initial orientational angle of the rotor that are valid for any magnitude of the initial angular momentum. The rotational rainbows appear as peaks both in the final angular momentum and rotational energy distributions, as well as peaks in the angular distribution, although the surface is assumed to be uncorrugated. The derived analytic expressions are compared with numerical simulation data. Even when the rotational motion is significantly coupled to the translational motion, the predictions of the perturbative treatment remain qualitatively correct.

  11. Blood circulation of the inner ear under the influence of medications. Radiotracer experiments using guinea pig cochlea

    International Nuclear Information System (INIS)

    Neumeier, A.

    1987-01-01

    The dependence of the blood circulation in the inner ear on various medications is discussed. By means of a radiotracer clearance technique the cochlear clearance curves for the guinea pig cochlea after the administration of various circulation stimulants were determined. (MBC) [de

  12. Uses and limits of radiotracers in the study of drugs and xenobiotics metabolism

    International Nuclear Information System (INIS)

    Cohen, Y.

    1980-01-01

    This review deals with scientific papers issued in 1977-1978, on labelling of drugs and xenobiotics and their metabolism. It is divided in five parts: site of label; in vivo metabolism in animals and human beings; in vitro metabolism on tissue slices, cells culture, microsomes, membrane receptors; metabolism of xenobiotics: nutrients, food additives, detergents, plastics and fabrics; discussion. Metabolic studies, nowadays, associate radiotracers, stable isotopes with high performing procedures for analytical separation [fr

  13. Flow produced in a conical container by a rotating endwall

    International Nuclear Information System (INIS)

    Escudier, M.P.; O'Leary, J.; Poole, R.J.

    2007-01-01

    Numerical calculations have been carried out for flow in a truncated cone generated by rotation of one endwall. For both convergent (radius increasing with approach to the rotating endwall) and divergent geometries, vortex breakdown is suppressed beyond a certain angle of inclination of the sidewall. At the same time Moffat eddies of increasing strength and extent appear in the corner between the sidewall and the non-rotating endwall. For the divergent geometry, a zone of recirculation appears on the sidewall and eventually merges with the Moffat eddies. The flow phenomena identified from streamline patterns are consistent with the calculated variation of pressure around the periphery of the computational domain

  14. Exact quantum cross sections for a three dimensional angle dependent model for three body reactions.

    Science.gov (United States)

    Baer, M.; Kouri, D. J.

    1971-01-01

    Exact quantum mechanical reactive cross sections are reported for a three dimensional angle dependent model surface. The surface simulates an atom-heteronuclear diatom system A + BC leading to AB + C where atom B is much heavier than A or C. The molecules BC and AB are taken to be rotating vibrators which can dissociate. Results for two angle dependent potentials are given.

  15. An oilspill trajectory analysis model with a variable wind deflection angle

    Science.gov (United States)

    Samuels, W.B.; Huang, N.E.; Amstutz, D.E.

    1982-01-01

    The oilspill trajectory movement algorithm consists of a vector sum of the surface drift component due to wind and the surface current component. In the U.S. Geological Survey oilspill trajectory analysis model, the surface drift component is assumed to be 3.5% of the wind speed and is rotated 20 degrees clockwise to account for Coriolis effects in the Northern Hemisphere. Field and laboratory data suggest, however, that the deflection angle of the surface drift current can be highly variable. An empirical formula, based on field observations and theoretical arguments relating wind speed to deflection angle, was used to calculate a new deflection angle at each time step in the model. Comparisons of oilspill contact probabilities to coastal areas calculated for constant and variable deflection angles showed that the model is insensitive to this changing angle at low wind speeds. At high wind speeds, some statistically significant differences in contact probabilities did appear. ?? 1982.

  16. Occlusal plane rotation: aesthetic enhancement in mandibular micrognathia.

    Science.gov (United States)

    Rosen, H M

    1993-06-01

    Patients afflicted with extreme degrees of mandibular micrognathia typically have vertically deficient rami as well as sagittally deficient mandibular bodies. This results in deficient posterior facial height, an obtuse gonial angle, excessively steep occlusal and mandibular planes, and a compensatory increase in anterior facial height. The entire maxillomandibular complex is overrotated in a clockwise direction. Standard orthognathic surgical correction fails to address this rotational deformity. As a consequence, the achieved projection of the lower face is inadequate, posterior facial height is further reduced, and occlusal and mandibular planes remain steep. Eleven patients with severe mandibular micrognathia underwent a surgical correction involving occlusal plane rotation to its normal orientation relative to Frankfort horizontal. This was accomplished by Le Fort I osteotomy to shorten the anterior maxilla (creating open bites in seven patients and making preexisting open bites worse in four patients) and sagittal split ramus osteotomies to advance and rotate the mandibular body counterclockwise, thus closing the surgically produced open bite. Counterclockwise rotation of the mandible afforded significantly greater sagittal displacement at the B point (mean 17 mm) than at the first molar (mean 10 mm) and produced adequate degrees of projection of the lower face when accompanied by a modest sliding genioplasty (mean 6.9 mm). Total advancement at the pogonion was a mean of 25.2 mm. In addition, posterior facial height was preserved, and mandibular and occlusal planes were normalized to mean angles of 27 and 10 degrees, respectively. At follow-up, which ranged from 9 to 24 months with a mean of 14.1 months, the mean sagittal relapse at the B point was 1.9 mm. Although heretofore considered unstable and therefore not clinically accepted, maxillomandibular counterclockwise rotation to normalize the occlusal plane rotational deformity provides stable, aesthetically

  17. Measuring contact angle and meniscus shape with a reflected laser beam.

    Science.gov (United States)

    Eibach, T F; Fell, D; Nguyen, H; Butt, H J; Auernhammer, G K

    2014-01-01

    Side-view imaging of the contact angle between an extended planar solid surface and a liquid is problematic. Even when aligning the view perfectly parallel to the contact line, focusing one point of the contact line is not possible. We describe a new measurement technique for determining contact angles with the reflection of a widened laser sheet on a moving contact line. We verified this new technique measuring the contact angle on a cylinder, rotating partially immersed in a liquid. A laser sheet is inclined under an angle φ to the unperturbed liquid surface and is reflected off the meniscus. Collected on a screen, the reflection image contains information to determine the contact angle. When dividing the laser sheet into an array of laser rays by placing a mesh into the beam path, the shape of the meniscus can be reconstructed from the reflection image. We verified the method by measuring the receding contact angle versus speed for aqueous cetyltrimethyl ammonium bromide solutions on a smooth hydrophobized as well as on a rough polystyrene surface.

  18. Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror

    Science.gov (United States)

    Li, Steven

    2011-01-01

    A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.

  19. Absorption and retention studies of trace elements and minerals in rats using radiotracers and whole-body counting

    NARCIS (Netherlands)

    Berg, van den G.J.; Wolterbeek, H.Th.; de Goeij, J.J.M.; Beynen, A.C.

    1995-01-01

    A description is given of a whole-body counting technique using radiotracers, permitting the determination of true absorption and endogenous excretion of trace elements and minerals in the rat in vivo. This non-invasive counting method involves oral and intraperitoneal administration of tracer doses

  20. Translate rotate scanning method for X-ray imaging

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Kwog Cheong Tam.

    1990-01-01

    Rapid x-ray inspection of objects larger than an x-ray detector array is based on a translate rotate scanning motion of the object related to the fan beam source and detector. The scan for computerized tomography imaging is accomplished by rotating the object through 360 degrees at two or more positions relative to the source and detector array, in moving to another position the object is rotated and the object or source and detector are translated. A partial set of x-ray data is acquired at every position which are combined to obtain a full data set for complete image reconstruction. X-ray data for digital radiography imaging is acquired by scanning the object vertically at a first position at one view angle, rotating and translating the object relative to the source and detector to a second position, scanning vertically, and so on to cover the object field of view, and combining the partial data sets. (author)

  1. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a vacuum pan for massecuite b and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the o n line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  2. Mixing studies at low grade vacuum pan using the radiotracer method

    International Nuclear Information System (INIS)

    Griffith, J.M

    1999-01-01

    In this paper, some preliminary results achieved in the evaluation of the homogenization time at a Vacuum Pan for massecuite B and seed preparation , using two approaches of the radiotracer method, are presented. Practically no difference between the Ion Line , using small size detector and the sampling methods, in mixing studies performed at the high-grade massecuite was detected. Results achieved during the trials performed at the vacuum station show that the mechanical agitation in comparison with normal agitation improves the performance of mixing in high-grade massecuite b and in seed preparation at the vacuum pan

  3. Risk Factors, Pathobiomechanics and Physical Examination of Rotator Cuff Tears

    Science.gov (United States)

    Moulton, Samuel G.; Greenspoon, Joshua A.; Millett, Peter J.; Petri, Maximilian

    2016-01-01

    Background: It is important to appreciate the risk factors for the development of rotator cuff tears and specific physical examination maneuvers. Methods: A selective literature search was performed. Results: Numerous well-designed studies have demonstrated that common risk factors include age, occupation, and anatomic considerations such as the critical shoulder angle. Recently, research has also reported a genetic component as well. The rotator cuff axially compresses the humeral head in the glenohumeral joint and provides rotational motion and abduction. Forces are grouped into coronal and axial force couples. Rotator cuff tears are thought to occur when the force couples become imbalanced. Conclusion: Physical examination is essential to determining whether a patient has an anterosuperior or posterosuperior tear. Diagnostic accuracy increases when combining a series of examination maneuvers. PMID:27708731

  4. Clinical variables in radiotracer biodistributions

    International Nuclear Information System (INIS)

    Lentle, B.C.; Scott, J.R.; Schmidt, R.P.; Noujaim, A.A.

    1981-01-01

    Radionuclide dosimetry must, by its nature, define tissue irradiation in terms of mean exposure in a population of a statistically acceptable size. In the daily practice of clinical nuclear medicine there are, however, quite large variations in the biodistribution of tracers and thus in resulting radiation doses. Age is a variable, particularly in respect of bone-seeking tracers. Sex imposes variations in radiation dose on account of the differing anatomical configurations of the gonads. Breast uptake and excretion of certain tracers in women are additional variables. Activity and occupation are occasional variables. Numerous iatrogenic causes of altered radiotracer biodistributions have been described. Cancer chemotherapy is a particularly potent cause of changed biodistributions while even a trivial matter such as preparing the skin with an iodine containing antiseptic may cause displacement of technetium from its compounds. In the blocking of thyroid uptake of radioiodines, there is good precedent for the manipulation of regional tissue dosimetry. It is possible to go beyond the mere cataloguing of these effects to look creatively at the subject of comparative tissue biodistributions and hence comparative dosimetry. Effects such as the clinical observation of the interference by cis-platinum with the usual biodistribution of radio-gallium suggest that such compounds can be used as probes each to lead to a better understanding of the mechanism of action of the other

  5. [{sup 11}C]CURB: Evaluation of a novel radiotracer for imaging fatty acid amide hydrolase by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, Alan A., E-mail: alan.wilson@camhpet.c [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Garcia, Armando; Parkes, Jun [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Houle, Sylvain [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Tong, Junchao [Department of Psychiatry, University of Toronto, Toronto, Ontario, M5T 1R8 (Canada); Vasdev, Neil [PET Centre, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada); Human Neurochemical Pathology Laboratory, Centre for Addiction and Mental Health, Toronto, Ontario, M5T 1R8 (Canada)

    2011-02-15

    Introduction: Fatty acid amide hydrolase (FAAH) is the enzyme responsible for metabolising the endogenous cannabinoid, anandamide, and thus represents an important target for molecular imaging. To date, no radiotracer has been shown to be useful for imaging of FAAH using either positron emission tomography (PET) or single photon emission computed tomography (SPECT). We here determine the suitability of a novel carbon-11-labeled inhibitor of FAAH via ex vivo biodistribution studies in rat brain in conjunction with pharmacological challenges. Methods: A potent irreversible inhibitor of FAAH, URB694, radiolabeled with carbon-11 in the carbonyl position ([{sup 11}C]CURB), was administered to male rats via tail-vein injection. Rats were sacrificed at various time points postinjection, and tissue samples were dissected, counted and weighed. Specific binding to FAAH was investigated by pretreatment of animals with URB694 or URB597. For metabolism and mechanism of binding studies, whole brains were excised post-radiotracer injection, homogenised and extracted exhaustively with 80% aq. acetonitrile to determine the time course and fraction of radioactivity that was irreversibly bound to brain parenchyma. Results: Upon intravenous injection into rats, [{sup 11}C]CURB showed high brain uptake [standard uptake value (SUV) of 1.6-2.4 at 5 min] with little washout over time, which is characteristic of irreversible binding. Highest uptake of radioactivity was seen in the cortex, intermediate in the cerebellum and lowest in the hypothalamus, reflecting the reported distribution of FAAH. Brain uptake of radioactivity was decreased in a dose-dependent manner by pretreatment with increasing amounts of URB694, demonstrating that binding was saturable. Pretreatment with the well-characterised FAAH inhibitor, URB597, reduced binding in all brain regions by 70-80%. Homogenised brain extraction experiments demonstrated unequivocally that [{sup 11}C]CURB was irreversibly bound to FAAH

  6. The changes of the interspace angle after anterior correction and instrumentation in adolescent idiopathic scoliosis patients

    Directory of Open Access Journals (Sweden)

    Fei Qi

    2007-10-01

    Full Text Available Abstract Background In idiopathic scoliosis patients, after anterior spinal fusion and instrumentation, the discs (interspace angle between the lowest instrumented vertebra (LIV and the next caudal vertebra became more wedged. We reviewed these patients and analyzed the changes of the angle. Methods By reviewing the medical records and roentgenograms of adolescent idiopathic scoliosis patients underwent anterior spinal fusion and instrumentation, Cobb angle of the curve, correction rate, coronal balance, LIV rotation, interspace angle were measured and analyzed. Results There were total 30 patients included. The mean coronal Cobb angle of the main curve (thoracolumbar/lumbar curve before and after surgery were 48.9° and 11.7°, respectively, with an average correction rate of 76.1%. The average rotation of LIV before surgery was 2.1 degree, and was improved to 1.2 degree after surgery. The interspace angle before surgery, on convex side-bending films, after surgery, at final follow up were 3.2°, -2.3°, 1.8° and 4.9°, respectively. The difference between the interspace angle after surgery and that preoperatively was not significant (P = 0.261, while the interspace angle at final follow-up became larger than that after surgery, and the difference was significant(P = 0.012. The interspace angle after surgery was correlated with that on convex side-bending films (r = 0.418, P = 0.022, and the interspace angle at final follow-up was correlated with that after surgery (r = 0.625, P = 0.000. There was significant correlation between the loss of the interspace angle and the loss of coronal Cobb angle of the main curve during follow-up(r = 0.483, P = 0.007. Conclusion The interspace angle could be improved after anterior correction and instrumentation surgery, but it became larger during follow-up. The loss of the interspace angle was correlated with the loss of coronal Cobb angle of the main curve during follow-up.

  7. Yaw Angle Error Compensation for Airborne 3-D SAR Based on Wavenumber-domain Subblock

    Directory of Open Access Journals (Sweden)

    Ding Zhen-yu

    2015-08-01

    Full Text Available Airborne array antenna SAR is used to obtain three-dimensional imaging; however it is impaired by motion errors. In particular, rotation error changes the relative position among the different antenna units and strongly affects the image quality. Unfortunately, the presently available algorithm can not compensate for the rotation error. In this study, an airborne array antenna SAR three-dimensional imaging model is discussed along with the effect of rotation errors, and more specifically, the yaw angle error. The analysis reveals that along- and cross-track wavenumbers can be obtained from the echo phase, and when used to calculate the range error, these wavenumbers lead to a target position irrelevant result that eliminates the error's spatial variance. Therefore, a wavenumber-domain subblock compensation method is proposed by computing the range error in the subblock of the along- and cross-track 2-D wavenumber domain and precisely compensating for the error in the space domain. Simulations show that the algorithm can compensate for the effect of yaw angle error.

  8. Radiotracer study on dispersion of sewerage off Mumbai Coast in Western India

    International Nuclear Information System (INIS)

    Kumar, U.S.; Yelgaonkar, V.N.; Navada, S.V.

    1997-01-01

    Municipal Corporation of Greater Mumbai discharges the treated sewage at various locations off Mumbai coast. One such discharge point is located near Colaba near South Mumbai. Screened, degritted and aerated sewage is discharged through a 1 m diameter steel pipe by gravity to the diffuser installed on the sea bed at 1.1 km away from the shore. A radiotracer study was carried out to evaluate the dilution and dispersion pattern of the sewage at different points from the disposal point. The experiment was carried out during high tide. About 110 GBq of 82 Br was used as the tracer. A dilution factor of about 5.5 x 10 3 was obtained at a distance of 4.3 km from the outfall. The dilution downshore was small even for a long distance due to strong unidirectional currents. Comparable dilution factors were also obtained by Brooks' model. Vertical tracer profiles showed that the waste plume was well mixed over a depth of 2 to 3 m from the surface. A 2-D advection simulation model was employed to simulate the spatial and temporal distribution of the radiotracer data. From the model simulation best fit was obtained for dispersion coefficients Dx = 15 m 2 .s -1 and Dy = 2m 2 .s -1 . The dispersion coefficients can be used for predicting the effluent dispersion under different outfall and disposal conditions. The tracer pattern at Colaba and Malad indicated no possibility of contamination of the beaches

  9. Internal wave patterns in enclosed density-stratified and rotating fluids

    NARCIS (Netherlands)

    Manders, A.M.A.

    2003-01-01

    Stratified fluids support internal waves, which propagate obliquely through the fluid. The angle with respectto the stratification direction is contrained: it is purely determined by the wave frequency and the strength of the density stratification (internal gravity waves) or the rotation rate

  10. Mechanism of action in VIVO of some pet radiotracers

    International Nuclear Information System (INIS)

    Sachinidis, J.J.; Egan, G.F.; Berlangieri, S.U.; Scott, A.M.

    1998-01-01

    Full text: Position Emission Tomography (PET) is a technique that utilises position-emitting radiopharmaceuticals to map the physiology, biochemistry and pharmacology of the human body. PET studies range from standard image displays that provide indices of physiological function to complex kinetic analysis methods for absolute quantification. This paper will review some of the important PET radiopharmaceuticals currently produced at the Austin and Repatriation Medical Centre, Melbourne and discuss their mechanism of action in vivo. Depending on their mechanism of action, PET radiopharmaceuticals may be divided into two categories. The first category is non-specific radiotracers which follow a biochemical pathway. The second category is specific radioligands which are involved in an interaction with a receptor transporter or a receptor site. Radiopharmaceuticals from the first category may be assessed using a single or two compartmental plasma-tissue model and allow a measurement of tissue extraction or metabolism.[ 15 O] water is a freely diffusable inert which is used for cerebral blood flow measurement; [ 18 F] FDG which follows the initial phases of glucose metabolism but does not enter the Krebs cycle after phosphorylation and therefore is effectively trapped in the cells, can be used for tissue glucose metabolism measurement in oncology, cardiology and neurology; and [ 18 F]fluoromisonidazole which is a bio-reductive drug that in vivo follows an intracellular reduction pathway, can be used for hypoxic tissue measurement in stroke and tumour evaluation. Radiopharmaceuticals from the second category may be assessed using a three-compartment model: - unmetabolised free ligand in plasma, - free ligand in tissue, - and specially bound ligand in tissue. These radiotracers such as [ 11 C] flumazenil, which is an antagonist with high affinity and selectivity for a central benzodiazepine receptors, are used to study the changes in density or affinity of these receptors

  11. UV-photochemical vapor generation of selenium for atomic absorption spectrometry: Optimization and 75Se radiotracer efficiency study

    Czech Academy of Sciences Publication Activity Database

    Rybínová, M.; Musil, Stanislav; Červený, J.; Vobecký, Miloslav; Rychlovský, P.

    2016-01-01

    Roč. 123, SEP (2016), s. 134-142 ISSN 0584-8547 R&D Projects: GA ČR GA14-23532S Institutional support: RVO:68081715 Keywords : UV-photochemical vapor generation * Selenium * 75Se radiotracer Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.241, year: 2016

  12. Application of photostress method in stress analysis of a rotating disc

    Directory of Open Access Journals (Sweden)

    P. Frankovský

    2014-10-01

    Full Text Available The presented article demonstrates the application of PhotoStressR method in stress analysis of a rotating disc of a constant thickness, which was made of a photoelastic material PS-1A. Isoclinic fringes were observed on the rotating disc using linear polarized light at revolutions 5 000 RPM. Observations were carried out under angle parameter 0 o to 90 o with 10 o increase. A set of isostatic lines of I and II set was made from the set of obtained isoclinic lines. During gradual increase of rotations of the rotating disc up to 17 000 RPM, and with circular polarized light, we observed the distribution of colourful isochromatic fringes on the rotating disc. The field of isochromatic fringes, gained experimentally, at 15 000 RPM was compared with the field which was gained by means of a numerical analysis.

  13. Chemistry and biology of radiotracers that target changes in sympathetic and parasympathetic nervous systems in heart disease.

    Science.gov (United States)

    Eckelman, William C; Dilsizian, Vasken

    2015-06-01

    Following the discovery of the sympathetic and parasympathetic nervous system, numerous adrenoceptor drugs were radiolabeled and potent radioligands were prepared in order to image the β-adrenergic and the muscarinic systems. But the greatest effort has been in preparing noradrenaline analogs, such as norepinephrine, (11)C-metahydroxyephedrine, and (123)I-metaiodobenzylguanidine that measure cardiac sympathetic nerve varicosities. Given the technical and clinical challenges in designing and validating targeted adrenoceptor-binding radiotracers, namely the heavily weighted flow dependence and relatively low target-to-background ratio, both requiring complicated mathematic analysis, and the inability of targeted adrenoceptor radioligands to have an impact on clinical care of heart disease, the emphasis has been on radioligands monitoring the norepinephrine pathway. The chemistry and biology of such radiotracers, and the clinical and prognostic impact of these innervation imaging studies in patients with heart disease, are examined. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Mental rotation versus invariant features in object perception from different viewpoints: an fMRI study.

    Science.gov (United States)

    Vanrie, Jan; Béatse, Erik; Wagemans, Johan; Sunaert, Stefan; Van Hecke, Paul

    2002-01-01

    It has been proposed that object perception can proceed through different routes, which can be situated on a continuum ranging from complete viewpoint-dependency to complete viewpoint-independency, depending on the objects and the task at hand. Although these different routes have been extensively demonstrated on the behavioral level, the corresponding distinction in the underlying neural substrate has not received the same attention. Our goal was to disentangle, on the behavioral and the neurofunctional level, a process associated with extreme viewpoint-dependency, i.e. mental rotation, and a process associated with extreme viewpoint-independency, i.e. the use of viewpoint-invariant, diagnostic features. Two sets of 3-D block figures were created that either differed in handedness (original versus mirrored) or in the angles joining the block components (orthogonal versus skewed). Behavioral measures on a same-different judgment task were predicted to be dependent on viewpoint in the rotation condition (same versus mirrored), but not in the invariance condition (same angles versus different angles). Six subjects participated in an fMRI experiment while presented with both conditions in alternating blocks. Both reaction times and accuracy confirmed the predicted dissociation between the two conditions. Neurofunctional results indicate that all cortical areas activated in the invariance condition were also activated in the rotation condition. Parietal areas were more activated than occipito-temporal areas in the rotation condition, while this pattern was reversed in the invariance condition. Furthermore, some areas were activated uniquely by the rotation condition, probably reflecting the additional processes apparent in the behavioral response patterns.

  15. Report of the Consultants’ Meeting on the “Establishment of a training and certification system for radiotracers and NCS applications”. Proceedings of a conference

    International Nuclear Information System (INIS)

    2013-01-01

    The International Atomic Energy Agency (IAEA) has been playing a major role in facilitating the transfer of the radiotracer and sealed sources technologies to developing Member States. The major techniques have been implemented through IAEA Technical Co-operation projects and adopted by many Member States. The expertise and knowledge gained should be preserved. The sustainability of technology and knowledge preservation calls for creation of young specialists and for continuing good practices. As a part of its involvement in human resource development, the IAEA is aware of the important need to prepare standard syllabi and training course materials for education of specialists in different fields of nuclear technologies. Training course materials on the radiotracer and sealed sources methods for industrial and environmental applications have been developed for the cultivation of radiation technologies specialists and for continuing technical education of practitioners worldwide. The wide interest in radiotracer technology has created the need for highlevel professional education and training in this field, which are not necessarily covered by traditional University courses. Radiotracers are playing more and more important roles in industry. These roles will continue to expand, especially if students and engineers are exposed in their academic training to the many possibilities for using this tool in research, development and applications. Beside this academic teaching aspect, it appears the need to create a structured training system, mainly for practitioners to ensure sustainability of the activity and to improve the recognition of the technologies and personal by the industries

  16. Optimal Full Waveform Inversion Strategy in Azimuthally Rotated Elastic Orthorhombic Media

    KAUST Repository

    Oh, Juwon; Alkhalifah, Tariq Ali

    2017-01-01

    The elastic orthorhombic assumption is one of the most practical Earth models that takes into account the horizontal anisotropic layering and vertical fracture network. In this model, the rotation angle of the vertical planes of symmetry is a

  17. The radiochemical purity of radiotracers as the criterion of their usefulness in investigations of hydrocarbons distillation

    International Nuclear Information System (INIS)

    Kolaczkowski, M.

    1976-01-01

    Among numerous analytic techniques of separation and analysis of radioactive products gas radiochromatography has proved to be particularly suitable. Organic bromides labelled with 82 Br-radionuclide are investigated. The analytic gas chromatographs equipped with appropriately constructed radiochromatographic attachments are used. The results of radiochemical purity determination of radiotracers are compared for various techniques. (author)

  18. Development of an Adjustable board and a Rotational Board for Scaffold

    Science.gov (United States)

    Jang, Myunghoun

    2017-06-01

    Scaffold is widely used in high work-places inside and outside of a building construction site. It is inexpensive and is installed and dismantled easily. Although standards and ledgers of a steel tube and coupler scaffold are installed in a regular distance, the distances of transoms are not equal in some places. Sometimes a working platform or a board is absent in the corner of scaffold. This may cause safety accidents because a foothold is not stable on the transoms. An adjustable safety board and a rotational safety board are suggested in this paper. The adjustable board consists of two footholds. The small one is inserted into the large one. The rotational board covers not only right angle but also acute or obtuse angles. These safety boards for scaffold help to decrease safety accidents in construction sites.

  19. Giant Faraday Rotation of High-Order Plasmonic Modes in Graphene-Covered Nanowires.

    Science.gov (United States)

    Kuzmin, Dmitry A; Bychkov, Igor V; Shavrov, Vladimir G; Temnov, Vasily V

    2016-07-13

    Plasmonic Faraday rotation in nanowires manifests itself in the rotation of the spatial intensity distribution of high-order surface plasmon polariton (SPP) modes around the nanowire axis. Here we predict theoretically the giant Faraday rotation for SPPs propagating on graphene-coated magneto-optically active nanowires. Upon the reversal of the external magnetic field pointing along the nanowire axis some high-order plasmonic modes may be rotated by up to ∼100° on the length scale of about 500 nm at mid-infrared frequencies. Tuning the carrier concentration in graphene by chemical doping or gate voltage allows for controlling SPP-properties and notably the rotation angle of high-order azimuthal modes. Our results open the door to novel plasmonic applications ranging from nanowire-based Faraday isolators to the magnetic control in quantum-optical applications.

  20. Effect of Channel Orientation and Rib Pitch-to-Height Ratio on Pressure Drop in a Rotating Square Channel with Ribs on Two Opposite Surfaces

    Directory of Open Access Journals (Sweden)

    Prabhu S. V.

    2005-01-01

    Full Text Available The effect of channel orientation and rib pitch-to-height ratio on the pressure drop distribution in a rib-roughened channel is an important issue in turbine blade cooling. The present investigation is a study of the overall pressure drop distribution in a square cross-sectioned channel, with rib turbulators, rotating about an axis normal to the free stream. The ribs are configured in a symmetric arrangement on two opposite surfaces with a rib angle of 90 ∘ to the mainstream flow. The study has been conducted for three Reynolds numbers, namely, 13 000, 17 000, and 22 000 with the rotation number varying from 0– 0.38 . Experiments have been carried out for various rib pitch-to-height ratios ( P/e with a constant rib height-to-hydraulic diameter ratio ( e/D of 0.1 . The test section in which the ribs are placed on the leading and trailing surfaces is considered as the base case ( orientation angle= 0 ∘ , Coriolis force vector normal to the ribbed surfaces. The channel is turned about its axis in steps of 15 ∘ to vary the orientation angle from 0 ∘ to 90 ∘ . The overall pressure drop does not change considerably under conditions of rotation for the base case. However, for the other cases tested, it is observed that the overall pressure drop increases with an increase in the rotation number for a given orientation angle and also increases with an increase in the orientation angle for a given rotation number. This change is attributed to the variation in the separation zone downstream of the ribs due to the presence of the Coriolis force—local pressure drop data is presented which supports this idea. At an orientation angle of 90 ∘ (ribs on the top and bottom surfaces, Coriolis force vector normal to the smooth surfaces, the overall pressure drop is observed to be maximum during rotation. The overall pressure drop for a case with a rib pitch-to-height ratio of 5 on both surfaces is found to be the highest

  1. Band structures in a two-dimensional phononic crystal with rotational multiple scatterers

    Science.gov (United States)

    Song, Ailing; Wang, Xiaopeng; Chen, Tianning; Wan, Lele

    2017-03-01

    In this paper, the acoustic wave propagation in a two-dimensional phononic crystal composed of rotational multiple scatterers is investigated. The dispersion relationships, the transmission spectra and the acoustic modes are calculated by using finite element method. In contrast to the system composed of square tubes, there exist a low-frequency resonant bandgap and two wide Bragg bandgaps in the proposed structure, and the transmission spectra coincide with band structures. Specially, the first bandgap is based on locally resonant mechanism, and the simulation results agree well with the results of electrical circuit analogy. Additionally, increasing the rotation angle can remarkably influence the band structures due to the transfer of sound pressure between the internal and external cavities in low-order modes, and the redistribution of sound pressure in high-order modes. Wider bandgaps are obtained in arrays composed of finite unit cells with different rotation angles. The analysis results provide a good reference for tuning and obtaining wide bandgaps, and hence exploring the potential applications of the proposed phononic crystal in low-frequency noise insulation.

  2. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique

    International Nuclear Information System (INIS)

    Pant, H.J.; Sharma, V.K.; Shenoy, K.T.; Sreenivas, T.

    2015-01-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40–60 MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. - Highlights: • Radiotracer technique was applied for evaluation of design of a pilot-scale continuous leaching reactor. • Mean residence time and dead volume were estimated. Dead volume was found to be ranging from 4% to 15% at different operating conditions. • Tank-in-series model was used to simulate the measured RTD data and was found suitable to describe the flow in the reactor. • No flow abnormality was found and the reactor behaved as a well-mixed system. The design of the reactor was validated

  3. The Dual-Angle Method for Fast, Sensitive T1 Measurement in Vivo with Low-Angle Adiabatic Pulses

    Science.gov (United States)

    Bottomley, P. A.; Ouwerkerk, R.

    A new method for measuring T1 based on a measurement of the ratio, R, of the steady-state partially saturated NMR signals acquired at two fixed low flip angles (hip-angle and excitation-field ( B1) inhomogeneity result in roughly proportionate errors in the apparent T1. The method is best implemented with adiabatic low-angle pulses such as B1-independent rotation (BIR-4) or BIR-4 phase-cycled (BIRP) pulses, which permit measurements with surface coils. Experimental validation was obtained at 2 T by comparison of unlocalized inversion-recovery and dual-angle proton ( 1H) and phosphorus ( 31P) measurements from vials containing doped water with 0.04 ≤ T1 ≤ 2.8 s and from the metabolites in the calf muscles of eight human volunteers. Calf muscle values of 6 ± 0.5 s for phosphocreatine and around 3.7 ± 0.8 s for the adenosine triphosphates (ATP) were in good agreement with inversion-recovery T1 values and values from the literature. Use of the dual-angle method accelerated T1 measurement time by about fivefold over inversion recovery. The dual-angle method was implemented in a one-dimensional localized surface-coil 31P spectroscopy sequence, producing consistent T1 measurements from phantoms, the calf muscle, and the human liver. 31P T1 values of ATP in the livers of six volunteers were about 0.5 ± 0.1 to 0.6 ± 0.2 s: the total exam times were about 35 minutes per subject. The method is ideally suited to low-sensitivity and/or low-concentration moieties, such as in 31P NMR in vivo, where study-time limitations are critical, and for rapid 1H T1 imaging.

  4. Low torque hydrodynamic lip geometry for bi-directional rotation seals

    Science.gov (United States)

    Dietle, Lannie L [Houston, TX; Schroeder, John E [Richmond, TX

    2009-07-21

    A hydrodynamically lubricating geometry for the generally circular dynamic sealing lip of rotary seals that are employed to partition a lubricant from an environment. The dynamic sealing lip is provided for establishing compressed sealing engagement with a relatively rotatable surface, and for wedging a film of lubricating fluid into the interface between the dynamic sealing lip and the relatively rotatable surface in response to relative rotation that may occur in the clockwise or the counter-clockwise direction. A wave form incorporating an elongated dimple provides the gradual convergence, efficient impingement angle, and gradual interfacial contact pressure rise that are conducive to efficient hydrodynamic wedging. Skewed elevated contact pressure zones produced by compression edge effects provide for controlled lubricant movement within the dynamic sealing interface between the seal and the relatively rotatable surface, producing enhanced lubrication and low running torque.

  5. Dynamic modelling and control of a rotating Euler-Bernoulli beam

    Science.gov (United States)

    Yang, J. B.; Jiang, L. J.; Chen, D. CH.

    2004-07-01

    Flexible motion of a uniform Euler-Bernoulli beam attached to a rotating rigid hub is investigated. Fully coupled non-linear integro-differential equations, describing axial, transverse and rotational motions of the beam, are derived by using the extended Hamilton's principle. The centrifugal stiffening effect is included in the derivation. A finite-dimensional model, including couplings of axial and transverse vibrations, and of elastic deformations and rigid motions, is obtained by the finite element method. By neglecting the axial motion, a simplified modelling, suitable for studying the transverse vibration and control of a beam with large angle and high-speed rotation, is presented. And suppressions of transverse vibrations of a rotating beam are simulated with the model by combining positive position feedback and momentum exchange feedback control laws. It is indicated that an improved performance for vibration control can be achieved with the method.

  6. Importance of body rotation during the flight of a butterfly.

    Science.gov (United States)

    Fei, Yueh-Han John; Yang, Jing-Tang

    2016-03-01

    In nature the body motion of a butterfly is clearly observed to involve periodic rotation and varied flight modes. The maneuvers of a butterfly in flight are unique. Based on the flight motion of butterflies (Kallima inachus) recorded in free flight, a numerical model of a butterfly is created to study how its flight relates to body pose; the body motion in a simulation is prescribed and tested with varied initial body angle and rotational amplitude. A butterfly rotates its body to control the direction of the vortex rings generated during flapping flight; the flight modes are found to be closely related to the body motion of a butterfly. When the initial body angle increases, the forward displacement decreases, but the upward displacement increases within a stroke. With increased rotational amplitudes, the jet flows generated by a butterfly eject more downward and further enhance the generation of upward force, according to which a butterfly executes a vertical jump at the end of the downstroke. During this jumping stage, the air relative to the butterfly is moving downward; the butterfly pitches up its body to be parallel to the flow and to decrease the projected area so as to avoid further downward force generated. Our results indicate the importance of the body motion of a butterfly in flight. The inspiration of flight controlled with body motion from the flight of a butterfly might yield an alternative way to control future flight vehicles.

  7. Reactor and /or accelerator: general remarks on strategic considerations in sourcing/producing radiopharmaceuticals and radiotracer for the Philippines

    International Nuclear Information System (INIS)

    Nazarea, A.D.

    1996-01-01

    The most important sources of radionuclides in the world are particle accelerators and nuclear reactors. Since the late 1940's many radiotracers and radiopharmaceuticals have been innovated and conceived, designed, produced and applied in important industrial and clinical/ biomedical settings. For example in the health area, reactor-produced radionuclides have become indispensable for diagnostic imaging involving, in its most recent and advanced development, radioimmunoscintigraphy, which exploits the exquisite ligand-specificity of monoclonal antibodies, reagents which in turn are the products of advances in biotechnology. Thus far, one of the most indispensable radiopharmaceuticals has been 99m Tc, which is usually obtained as a daughter decay product of 99 Mo. In January 1991, some questions about the stability of the worldwide commercial supply of 99 Mo became highlighted when the major commercial world producer of 99 Mo, Nordion International, shut down its facilities temporarily in Canada due to contamination in its main reactor building (see for instance relevant newsbrief in J. Nuclear Medicine (1991): 'Industry agrees to join DOE study of domestic moly-99 production'). With the above background, my remarks will attempt to open discussions on strategic considerations relevant to questions of 'self reliance' in radiotracers/radiopharmaceutical production in the Philippines. For instance, the relevant question of sourcing local radionuclide needs from a fully functioning multipurpose cyclotron facility within the country that will then supply the needs of the local industrial, biomedical (including research) and health sectors; and possibly, eventually acquiring the capability to export to nearby countries longer-lived radiotracers and radiopharmaceuticals

  8. Imaging of Non-Prostate Cancers Using PSMA-Targeted Radiotracers: Rationale, Current State of the Field, and a Call to Arms.

    Science.gov (United States)

    Salas Fragomeni, Roberto A; Amir, Tali; Sheikhbahaei, Sara; Harvey, Susan C; Javadi, Mehrbod S; Solnes, Lilja; Kiess, Ana; Allaf, Mohamad E; Pomper, Martin; Gorin, Michael A; Rowe, Steven P

    2018-03-15

    Prostate-specific membrane antigen (PSMA) is a type II transmembrane glycoprotein that is highly overexpressed on prostate cancer epithelial cells and for which there is a growing body of literature examining the role of small molecule and antibody radiotracers targeted against this protein for prostate cancer detection and therapy. Despite its name, PSMA is also expressed, to varying degrees, in the neovasculature of a wide variety of non-prostate cancers; indeed, the pathology literature is replete with promising immunohistochemistry findings. A number of groups have begun to correlate those pathology-level results with in vivo imaging and therapy in non-prostate cancers using the same PSMA-targeted agents that have been so successful in prostate cancer. The potential to leverage radiotracers targeted to PSMA beyond prostate cancer is a promising approach for many cancers, and PSMA-targeted agents may be able to supplement or fill gaps left by other agents. However, to date, the majority of the reported findings with PSMA-targeted radiotracers in non-prostate malignancies has been in case reports and small case series, and the field must adopt a more thorough approach to the design and execution of larger prospective trials in order to realize the potential of these promising agents outside of prostate cancer. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Note: high precision angle generator using multiple ultrasonic motors and a self-calibratable encoder.

    Science.gov (United States)

    Kim, Jong-Ahn; Kim, Jae Wan; Kang, Chu-Shik; Jin, Jonghan; Eom, Tae Bong

    2011-11-01

    We present an angle generator with high resolution and accuracy, which uses multiple ultrasonic motors and a self-calibratable encoder. A cylindrical air bearing guides a rotational motion, and the ultrasonic motors achieve high resolution over the full circle range with a simple configuration. The self-calibratable encoder can compensate the scale error of a divided circle (signal period: 20") effectively by applying the equal-division-averaged method. The angle generator configures a position feedback control loop using the readout of the encoder. By combining the ac and dc operation mode, the angle generator produced stepwise angular motion with 0.005" resolution. We also evaluated the performance of the angle generator using a precision angle encoder and an autocollimator. The expanded uncertainty (k = 2) in the angle generation was estimated less than 0.03", which included the calibrated scale error and the nonlinearity error. © 2011 American Institute of Physics

  10. Radiotracer investigation to study residence time distribution in an evaporator system

    Energy Technology Data Exchange (ETDEWEB)

    Pant, H J; Yelgaonkar, V N; Navada, S V [Isotope Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    Determination of mean residence time, residence time distribution and evaluation of flow behavior in industrial process systems is of prime importance in order to control the process and to evaluate the performance of the process systems. This paper describes a case study carried out in an evaporator system in a sugar factory near Pune for determination of the mean residence time and residence time distribution using radiotracer technique. The mean residence time (MRT) was determined to be 4 seconds. The mathematical modelling of residence time distribution (RTD) data indicated the flow behaviour of the system to be a well mixed type. (author). 5 refs., 2 figs., 1 tab.

  11. A blind video watermarking scheme resistant to rotation and collusion attacks

    Directory of Open Access Journals (Sweden)

    Amlan Karmakar

    2016-04-01

    Full Text Available In this paper, Discrete Cosine Transform (DCT based blind video watermarking algorithm is proposed, which is perceptually invisible and robust against rotation and collusion attacks. To make the scheme resistant against rotation, watermark is embedded within the square blocks, placed on the middle position of every luminance channel. Then Zernike moments of those square blocks are calculated. The rotation invariance property of the Complex Zernike moments is exploited to predict the rotation angle of the video at the time of extraction of watermark bits. To make the scheme robust against collusion, design of the scheme is done in such a way that the embedding blocks will vary for the successive frames of the video. A Pseudo Random Number (PRN generator and a permutation vector are used to achieve the goal. The experimental results show that the scheme is robust against conventional video attacks, rotation attack and collusion attacks.

  12. Design of laboratory radiotracer studies in marine radioecology

    International Nuclear Information System (INIS)

    Schulte, E.H.

    1997-01-01

    A condensed description of methods used in laboratory radiotracer studies in marine radioecology is presented showing also the difficulties which may be encountered in order to obtain realistic and comparable information on the general behaviour of radionuclides in marine organisms. Practical guidance on the choice of the biological material and how to setup laboratory experiments and to control properly important experimental conditions are given. Key parameters like concentration factors and biological half-lives are defined and the theoretical estimation and practical determination of input, uptake, accumulation and loss of radionuclides in marine biota are formulated by the aid of mathematical equations. Examples of uptake and loss curves obtained in the laboratory are shown. The importance of some environmental factors (temperature, food, growth) on uptake and loss of radionuclides are demonstrated. Comparison of experimental and field data of concentration factors is reported to show the difficulty in extrapolating from laboratory experiments to nature. (author)

  13. Rotation sequence to report humerothoracic kinematics during 3D motion involving large horizontal component: application to the tennis forehand drive.

    Science.gov (United States)

    Creveaux, Thomas; Sevrez, Violaine; Dumas, Raphaël; Chèze, Laurence; Rogowski, Isabelle

    2018-03-01

    The aim of this study was to examine the respective aptitudes of three rotation sequences (Y t X f 'Y h '', Z t X f 'Y h '', and X t Z f 'Y h '') to effectively describe the orientation of the humerus relative to the thorax during a movement involving a large horizontal abduction/adduction component: the tennis forehand drive. An optoelectronic system was used to record the movements of eight elite male players, each performing ten forehand drives. The occurrences of gimbal lock, phase angle discontinuity and incoherency in the time course of the three angles defining humerothoracic rotation were examined for each rotation sequence. Our results demonstrated that no single sequence effectively describes humerothoracic motion without discontinuities throughout the forehand motion. The humerothoracic joint angles can nevertheless be described without singularities when considering the backswing/forward-swing and the follow-through phases separately. Our findings stress that the sequence choice may have implications for the report and interpretation of 3D joint kinematics during large shoulder range of motion. Consequently, the use of Euler/Cardan angles to represent 3D orientation of the humerothoracic joint in sport tasks requires the evaluation of the rotation sequence regarding singularity occurrence before analysing the kinematic data, especially when the task involves a large shoulder range of motion in the horizontal plane.

  14. Analysis of the changing Solar Radiation Angle on Hainan Island

    Directory of Open Access Journals (Sweden)

    Ge Zhiwu

    2017-01-01

    Full Text Available As the only tropical provinces in China, Hainan province has advantageous geographical location, and abundant solar energy resources. But because of Local ideas and habits, especially the lack of theoretical research on local solar resources, development and application of solar energy in Hainan is almost blank. In this paper, we studied the variation regularity of sunlight angle on Hainan tropical island, analyzed the revolution and rotation of the earth, and the change rule of sunlight angle caused by the sun’s movement between the tropic of cancer and the tropic of capricorn, deduced the change rule of sunlight angle in the spring equinox, the autumnal equinox, summer solstice and winter solstice day, and got the movement rules of solar elevation angle throughout the year. Theoretic analysis is consistent with field measurement results. These rules are of importance and can effectively guide the local People’s daily life and production, such as the reasonable layout of the buildings, floor distance between different heights of buildings, the direction of the lighting windows of tall buildings, installation angle of photovoltaic panels, and other similar solar energy absorbing and conversion equipment.

  15. Patient-specific rhytidectomy: finding the angle of maximal rejuvenation.

    Science.gov (United States)

    Jacono, Andrew A; Ransom, Evan R

    2012-09-01

    Rhytidectomy is fundamentally an operation of tissue release and resuspension, although the manner and direction of suspension are subject to perpetual debate. The authors describe a method for identifying the angle of maximal rejuvenation during rhytidectomy and quantify the resulting angle and its relationship to patient age. Patients were prospectively enrolled; demographic data, history, and operative details were recorded. Rhytidectomies were performed by the senior author (AAJ). After complete elevation, the face-lift flap was rotated in a medially-based arc (0-90°) while attention was given to the submental area, jawline, and midface. The angle of maximal rejuvenation for each hemiface was identified as described, and the flap was resuspended. During redraping, measurements of vertical and horizontal skin excess were recorded in situ. The resulting angle of lift was then calculated for each hemiface using trigonometry. Symmetry between sides was determined, and the effect of patient age on this angle was assessed. Three hundred hemifaces were operated (147 women; 3 men). Mean age was 60 years (range, 37-80 years). Mean resulting angle for the cohort was 60° from horizontal (range, 46-77°). This was inversely correlated with patient age (r = -.3). Younger patients (<50 years, 64°) had a significantly more vertical angle than older patients (≥70 years, 56°; P < .0002). No significant intersubject difference was found between hemifaces (P = .53). The authors present a method for identifying the angle of maximal rejuvenation during rhytidectomy. This angle was more superior than posterior in all cases and is intimately related to patient age. Lasting results demand a detailed anatomical understanding and strict attention to the direction and degree of laxity.

  16. Quantification of Finger-Tapping Angle Based on Wearable Sensors.

    Science.gov (United States)

    Djurić-Jovičić, Milica; Jovičić, Nenad S; Roby-Brami, Agnes; Popović, Mirjana B; Kostić, Vladimir S; Djordjević, Antonije R

    2017-01-25

    We propose a novel simple method for quantitative and qualitative finger-tapping assessment based on miniature inertial sensors (3D gyroscopes) placed on the thumb and index-finger. We propose a simplified description of the finger tapping by using a single angle, describing rotation around a dominant axis. The method was verified on twelve subjects, who performed various tapping tasks, mimicking impaired patterns. The obtained tapping angles were compared with results of a motion capture camera system, demonstrating excellent accuracy. The root-mean-square (RMS) error between the two sets of data is, on average, below 4°, and the intraclass correlation coefficient is, on average, greater than 0.972. Data obtained by the proposed method may be used together with scores from clinical tests to enable a better diagnostic. Along with hardware simplicity, this makes the proposed method a promising candidate for use in clinical practice. Furthermore, our definition of the tapping angle can be applied to all tapping assessment systems.

  17. Correlation between physical examination and three-dimensional gait analysis in the assessment of rotational abnormalities in children with cerebral palsy.

    Science.gov (United States)

    Teixeira, Fernando Borge; Ramalho Júnior, Amancio; Morais Filho, Mauro César de; Speciali, Danielli Souza; Kawamura, Catia Miyuki; Lopes, José Augusto Fernandes; Blumetti, Francesco Camara

    2018-01-01

    Objective To evaluate the correlation between physical examination data concerning hip rotation and tibial torsion with transverse plane kinematics in children with cerebral palsy; and to determine which time points and events of the gait cycle present higher correlation with physical examination findings. Methods A total of 195 children with cerebral palsy seen at two gait laboratories from 2008 and 2016 were included in this study. Physical examination measurements included internal hip rotation, external hip rotation, mid-point hip rotation and the transmalleolar axis angle. Six kinematic parameters were selected for each segment to assess hip rotation and shank-based foot rotation. Correlations between physical examination and kinematic measures were analyzed by Spearman correlation coefficients, and a significance level of 5% was considered. Results Comparing physical examination measurements of hip rotation and hip kinematics, we found moderate to strong correlations for all variables (pphysical examination and hip rotation kinematics (rho range: 0.48-0.61). Moderate correlations were also found between the transmalleolar axis angle measurement on physical examination and foot rotation kinematics (rho range 0.44-0.56; p<0.001). Conclusion These findings may have clinical implications in the assessment and management of transverse plane gait deviations in children with cerebral palsy.

  18. Radiotracers for per studies of neurotransmitter binding sites: Design considerations

    International Nuclear Information System (INIS)

    Kilbourn, M.R.

    1991-01-01

    Neurotransmitter binding sites, such as receptors, neuronal uptake systems, and vesicular uptake systems, are important targets for new radiopharmaceutical design. Selection of potential radioligands can be guided by in vitro laboratory data including such characteristics as selectivity and affinity for specific binding sites. However, development of PET radiotracers for use in vivo must include considerations of in vivo pharmacokinetics and metabolism. Introduction of potential radioligands is further narrowed by the demands of the radiochemical synthesis, which must produce radioligands of high chemical and radiochemical purity and of high specific activity. This paper will review examples of previous and current attempts by radiopharmaceutical chemists to meet these demands for new positron emitter-labeled radioligands for PET studies of a wide array of neurotransmitter binding sites

  19. Chuck for machining armature casings and angles

    International Nuclear Information System (INIS)

    Tashlitskii, A.I.; Matskevich, A.I.

    1984-01-01

    When machining T-joints and angles, the test specimen must be fixed before being placed in the desired position. This is quite a complex operation and is achieved in a few stages. At the Scientific Production Combine ''Kislorodmash,'' a new chuck was designed which in one pressing of the jaws seats and fixes the specimen. In the clamped condition, the chuck helps rotate and fix the specimen in one of the four positions. Rotating and fixing are manual. The chuck developed ensured a distinct interdependence of the axes of the branches being machined as the specimen remains fixed throughout the period of machining, and provides reliable fixing of the specimen, and there are no clearances when the specimen is fixed with a special wedge. When using the chuck, the ancillary movements of the operator are reduced to a minimum thus increasing the labor productivity

  20. Single-Molecule Analysis of the Rotation of F1-ATPase under High Hydrostatic Pressure

    Science.gov (United States)

    Okuno, Daichi; Nishiyama, Masayoshi; Noji, Hiroyuki

    2013-01-01

    F1-ATPase is the water-soluble part of ATP synthase and is an ATP-driven rotary molecular motor that rotates the rotary shaft against the surrounding stator ring, hydrolyzing ATP. Although the mechanochemical coupling mechanism of F1-ATPase has been well studied, the molecular details of individual reaction steps remain unclear. In this study, we conducted a single-molecule rotation assay of F1 from thermophilic bacteria under various pressures from 0.1 to 140 MPa. Even at 140 MPa, F1 actively rotated with regular 120° steps in a counterclockwise direction, showing high conformational stability and retention of native properties. Rotational torque was also not affected. However, high hydrostatic pressure induced a distinct intervening pause at the ATP-binding angles during continuous rotation. The pause was observed under both ATP-limiting and ATP-saturating conditions, suggesting that F1 has two pressure-sensitive reactions, one of which is evidently ATP binding. The rotation assay using a mutant F1(βE190D) suggested that the other pressure-sensitive reaction occurs at the same angle at which ATP binding occurs. The activation volumes were determined from the pressure dependence of the rate constants to be +100 Å3 and +88 Å3 for ATP binding and the other pressure-sensitive reaction, respectively. These results are discussed in relation to recent single-molecule studies of F1 and pressure-induced protein unfolding. PMID:24094404

  1. Measurement of residence time distribution of liquid phase in an industrial-scale continuous pulp digester using radiotracer technique.

    Science.gov (United States)

    Sheoran, Meenakshi; Goswami, Sunil; Pant, Harish J; Biswal, Jayashree; Sharma, Vijay K; Chandra, Avinash; Bhunia, Haripada; Bajpai, Pramod K; Rao, S Madhukar; Dash, A

    2016-05-01

    A series of radiotracer experiments was carried out to measure residence time distribution (RTD) of liquid phase (alkali) in an industrial-scale continuous pulp digester in a paper industry in India. Bromine-82 as ammonium bromide was used as a radiotracer. Experiments were carried out at different biomass and white liquor flow rates. The measured RTD data were treated and mean residence times in individual digester tubes as well in the whole digester were determined. The RTD was also analyzed to identify flow abnormalities and investigate flow dynamics of the liquid phase in the pulp digester. Flow channeling was observed in the first section (tube 1) of the digester. Both axial dispersion and tanks-in-series with backmixing models preceded with a plug flow component were used to simulate the measured RTD and quantify the degree of axial mixing. Based on the study, optimum conditions for operating the digester were proposed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Secondary flows and particle centrifugation in slightly tilted rotating pipes

    NARCIS (Netherlands)

    Brouwers, J.J.H.

    1995-01-01

    A theoretical analysis is presented of viscous incompressible laminar flow in a pipe which rotates around an axis held at small angle with respect to its symmetry-axis. Analogous to the results of Barua and Benton [1, 2], solutions in closed-form are given for circulatory flows in the

  3. A simple and efficient in vitro method for metabolism studies of radiotracers

    International Nuclear Information System (INIS)

    Lee, Sang-Yoon; Choe, Yearn Seong; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo; Kim, Byung-Tae

    2001-01-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[ 18 F]fluoromethylbenzyl- ([ 18 F]1) and 4-[ 18 F]fluorobenzyl-piperidine moieties ([ 18 F]2) was studied and compared with the in vivo metabolism. Defluorination of the [ 18 F]1 mainly occurred to generate [ 18 F]fluoride ion both in vitro and in vivo. In contrast, the [ 18 F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[ 18 F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers

  4. Dragging of inertial frames inside the rotating neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Chandrachur; Modak, Kamakshya Prasad; Bandyopadhyay, Debades, E-mail: chandrachur.chakraborty@saha.ac.in, E-mail: kamakshya.modak@saha.ac.in [Astroparticle Physics and Cosmology Division, Saha Institute of Nuclear Physics, Kolkata 700064 (India)

    2014-07-20

    We derive the exact frame-dragging rate inside rotating neutron stars. This formula is applied to show that the frame-dragging rate monotonically decreases from the center to the surface of the neutron star along the pole. In the case of the frame-dragging rate along the equatorial distance, it decreases initially away from the center, becomes negligibly small well before the surface of the neutron star, rises again, and finally approaches to a small value at the surface. The appearance of a local maximum and minimum in this case is the result of the dependence of frame-dragging frequency on the distance and angle. Moving from the equator to the pole, it is observed that this local maximum and minimum in the frame-dragging rate along the equator disappear after crossing a critical angle. It is also noted that the positions of the local maximum and minimum of the frame-dragging rate along the equator depend on the rotation frequency and central energy density of a particular pulsar.

  5. Instrumental neutron activation analysis of human hair and related radiotracer experiments on washing and leaching

    International Nuclear Information System (INIS)

    Das, H.A.; Hoede, D.; Sloot, H.A. van der; Herber, R.F.M.

    1981-11-01

    The work done under the IAEA-contract 2440/RB is summarized. The aim was to develop a fast and reliable system for the determination of tracer elements in human head hair by instrumental neutron activation analysis (INAA) and radiotracer washing experiments. The standardized procedure for INAA was applied to hair samples collected by the Coronel Laboratory of the University of Amsterdam. The correlation between trace element contents is considered

  6. Magnetic field and rotation effects on peristaltic transport of a Jeffrey fluid in an asymmetric channel

    International Nuclear Information System (INIS)

    Abd-Alla, A.M.; Abo-Dahab, S.M.

    2015-01-01

    In this paper, the peristaltic flow of a Jeffrey fluid in an asymmetric rotating channel is studied. Mathematical modeling is carried out by utilizing long wavelength and low Reynolds number assumptions. Closed form expressions for the pressure gradient, pressure rise, streamlines, axial velocity and shear stress on the channel walls have been computed numerically. Effects of Hartmann number, the ratio of relaxation to retardation times, time-mean flow, rotation and the phase angle on the pressure gradient, pressure rise, streamline, axial velocity and shear stress are discussed in detail and shown graphically. The results indicate that the effect of the Hartmann number, the ratio of relaxation to retardation times, time-mean flow, rotation and the phase angle are very pronounced in the phenomena. Comparison was made with the results obtained in the asymmetric channel and symmetric channel. - Highlights: • The peristaltic flow of a Jeffrey fluid in an asymmetric rotating channel with magnetic field. • Mathematical modeling for long wavelength and low Reynolds number assumptions. • Closed form expressions for the pressure gradient, pressure rise, stream function, axial velocity and shear stress

  7. Magic-Angle-Spinning NMR Magnet Development: Field Analysis and Prototypes

    Science.gov (United States)

    Voccio, John; Hahn, Seungyong; Park, Dong Keun; Ling, Jiayin; Kim, Youngjae; Bascuñán, Juan; Iwasa, Yukikazu

    2013-01-01

    We are currently working on a program to complete a 1.5 T/75 mm RT bore magic-angle-spinning nuclear magnetic resonance magnet. The magic-angle-spinning magnet comprises a z-axis 0.866-T solenoid and an x-axis 1.225-T dipole, each to be wound with NbTi wire and operated at 4.2 K in persistent mode. A combination of the fields creates a 1.5-T field pointed at 54.74 degrees (magic angle) from the rotation (z) axis. In the first year of this 3-year program, we have completed magnetic analysis and design of both coils. Also, using a winding machine of our own design and fabrication, we have wound several prototype dipole coils with NbTi wire. As part of this development, we have repeatedly made successful persistent NbTi-NbTi joints with this multifilamentary NbTi wire. PMID:24058275

  8. Evaluation of bone-seeking novel radiotracer {sup 68}Ga-NO2AP-Bisphosphonate for the detection of skeletal metastases in carcinoma breast

    Energy Technology Data Exchange (ETDEWEB)

    Passah, Averilicia; Tripathi, Madhavi; Ballal, Sanjana; Yadav, Madhav Prasad; Kumar, Rajeev; Chakraborty, Partha Sarathi; Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, Ansari Nagar, New Delhi (India); Roesch, Frank; Meckel, Marian [Johannes-Gutenberg-University, Nuclear Chemistry, Mainz (Germany)

    2017-01-15

    The successful labelling of bisphosphonates (BP) with {sup 68}Ga using macrocyclic chelators such as the based triazacyclononane (NO2AP) is a step forward in the in-house availability of a novel bone-seeking PET radiopharmaceutical with dual advantage of PET/CT imaging and generator production. In this study, we compared the novel generator-based skeletal radiotracer {sup 68}Ga-1,4,7-triazacyclonone-1,4-diacetic acid ({sup 68}Ga-NO2AP-BP) with sodium fluoride ({sup 18}F-NaF) for the detection of skeletal metastases in breast cancer patients. In addition, dosimetric analysis of {sup 68}Ga-NO2AP-BP was performed in a subset of patients. This was a prospective study of histopathologically proven cases of breast cancer patients who were referred for bone scintigraphy and underwent positron emission tomography/computed tomography (PET/CT) with {sup 18}F-NaF and {sup 68}Ga-NO2AP-BP within a week in random order. The scans of each patient were compared both qualitatively for image quality and quantitatively for number of lesions and SUVmax of lesions. Dosimetric analysis was performed in five patients. Their PET/CT scans were acquired at multiple time points and urine and blood samples were collected. Dosimetric calculations were performed using OLINDA/EXM 1.1 software. Statistical analysis was done using Stata 13 (StataCorp) software package. An agreement analysis regarding number of lesions detected with the two skeletal radiotracers was carried out. The image quality of {sup 68}Ga-NO2AP-BP PET/CT scans were comparable to that of {sup 18}F-NaF. There was no statistically significant difference in the SUVmax of lesions, normal bone and lesion to background ratio between the two skeletal radiotracers. There was good agreement in the number of lesions detected by both skeletal radiotracers. The mean whole body effective dose for {sup 68}Ga-NO2AP-BP was 0.00583 mSv/MBq and the effective dose equivalent was 0.0086 mSv/MBq. The excellent lesion detection agreement between

  9. Combination of sealed source and radiotracer technique to understand malfunctioning in a chemical plant

    Energy Technology Data Exchange (ETDEWEB)

    Yelgaonkar, V.N. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)], E-mail: vivekyel@rediffmail.com; Jayakumar, T.K.; Singh, Sudhir; Sharma, M.K. [Quality Assurance and Isotope Applications Services, BRIT, Vashi Complex, Navi Mumbai 400705 (India)

    2009-07-15

    Pure terphthalic acid (PTA) is produced by the oxidation of paraxylene in an oxidation reactor of a PTA plant. Since the reaction is exothermic, the temperature rises above 210 deg. C. Vapours formed in the reactor are passed through a series of heat exchangers and the cooled liquid is fed back to the reactor, which flows to the reactor by gravity. In one of the heat exchangers, improper flow distribution in the inlet and outlet pipelines was suspected. Maldistribution of flow in the heat exchanger was also suspected. Gamma scanning of the pipelines and a radiotracer experiment were carried out in the heat exchanger to study the malfunctioning. A specially fabricated pipe scanner was used to scan both 24 in diameter and 16 in diameter pipelines. From gamma scanning of the pipelines mostly on the bends, absence of the full bore flow of the liquid was observed. Presence of vapours along with the liquid could be obstructing the liquid flow, thereby causing the malfunctioning. A radiotracer experiment was also carried out to study the flow pattern in the heat exchanger. From the experiment, mean residence time of the heat exchanger was estimated as 470 s, which theoretically should be about 102 s. It indicated that the flow is decelerated in the heat exchanger because of the presence of vapour lock in the tube side.

  10. Radiotracer technique to study movement of pollutants in an alluvial aquifer

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2001-01-01

    Radioisotopes are being used as tracers in many research areas. Their use in determination of groundwater flow velocity is well known. They also provide insight into the understanding the hydrological systems. In this paper, pollutant movement in an alluvial aquifer in the Ganga basin near Kanpur is evaluated using radiotracer method. Radioactive 82 Br in the form of aqueous ammonium bromide was used as a tracer to measure filtration velocity of the groundwater in the vicinity of an effluent storage lagoon of a fertilizer plant at Kanpur, U.P. Point dilution technique in a single well was applied. Filtration velocity so obtained provided relevant information about the pollutant movement in the groundwater. (author)

  11. Metasurface for multi-channel terahertz beam splitters and polarization rotators

    Science.gov (United States)

    Zang, XiaoFei; Gong, HanHong; Li, Zhen; Xie, JingYa; Cheng, QingQing; Chen, Lin; Shkurinov, Alexander P.; Zhu, YiMing; Zhuang, SongLin

    2018-04-01

    Terahertz beam splitters and polarization rotators are two typical devices with wide applications ranging from terahertz communication to system integration. However, they are faced with severe challenges in manipulating THz waves in multiple channels, which is desirable for system integration and device miniaturization. Here, we propose a method to design ultra-thin multi-channel THz beam splitters and polarization rotators simultaneously. The reflected beams are divided into four beams with nearly the same density under illumination of linear-polarized THz waves, while the polarization of reflected beams in each channel is modulated with a rotation angle or invariable with respect to the incident THz waves, leading to the multi-channel polarization rotator (multiple polarization rotation in the reflective channels) and beam splitter, respectively. Reflective metasurfaces, created by patterning metal-rods with different orientations on a polyimide film, were fabricated and measured to demonstrate these characteristics. The proposed approach provides an efficient way of controlling polarization of THz waves in various channels, which significantly simplifies THz functional devices and the experimental system.

  12. Vulnerability of positron emission tomography radiotracers to endogenous competition

    International Nuclear Information System (INIS)

    Laruelle, M.; Huang, Y.

    2001-01-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels

  13. Vulnerability of positron emission tomography radiotracers to endogenous competition

    Energy Technology Data Exchange (ETDEWEB)

    Laruelle, M.; Huang, Y. [Columbia University College of Physicians and Surgeons and State Psychiatric Institute, Dept. of Psychiatry and Radiology, New York, NY (United States)

    2001-06-01

    PET and SPECT neuro receptor imaging techniques combined with pharmacological challenges have been introduce to measure acute fluctuations of synaptic dopamine (DA) concentrations in the living human brain. Changes in the in vivo binding of radioligands following manipulation of transmitter levels are generally believed to be driven by binding competition between the radioligand and neurotransmitter. This imaging modality has been very successful in the study of DA transmission at D2 receptors. Yet, the extension of this technique to the study of other neurotransmitter systems has proven difficult. This paper reviews recent evidence suggesting that simple binding competition might not be the only phenomenon regulating transmitter-radioligand interactions in vivo, and examines emerging data indicating that receptor trafficking might also be involved. A better understanding of the mechanisms underlying these interactions should facilitate the development of PET and SPECT radiotracers suitable for the reporting of synaptic transmitter levels.

  14. Application of photostress method in stress analysis of a rotating disc

    OpenAIRE

    Frankovský, P.; Trebuňa, F.

    2014-01-01

    The presented article demonstrates the application of PhotoStressR method in stress analysis of a rotating disc of a constant thickness, which was made of a photoelastic material PS-1A. Isoclinic fringes were observed on the rotating disc using linear polarized light at revolutions 5 000 RPM. Observations were carried out under angle parameter 0 o to 90 o with 10 o increase. A set of isostatic lines of I and II set was made from the set of obtained isoclinic lines. During gradual increase of ...

  15. The influence of molecular weight in radiotracers of inflamators processes

    International Nuclear Information System (INIS)

    Mesa Duennas, N.; Zayas Crespo, F.; Piedra Mazorra, J.; Diaz Barreto, M; Rodriguez Alfonso, M.E.; Perez Fuentes, A.

    2004-01-01

    Four 99mTc-radiopharmaceuticals (RPs) were compared as a radiotracers of inflammatory process. The RPs were divided in two groups according to their molecular weights and nature. One group included the human IgG and the ior t3 MoAb (anti-CD3), another included the Ciprofloxacine and the DMSA. The RPs were studied by different quality controls, and a biodistribution study in an aseptic inflammatory model made by steril Carragenin. The results obtained in the reduction of the immunoglobulins with 2-mercaptoethanol and sodium metabisulphite demonstrated that both reducing agents were equivalent, because the radiochemical purity obtained were similar and independent of the immunoglobulins. The biodistribution demonstrated a higher incorporation for the radiopharmaceuticals of high molecular weight, and the highest values were obtained with the 2-mercaptoethanol

  16. Quality control for measurement of soil samples containing 237Np and 241Am as radiotracer

    International Nuclear Information System (INIS)

    Sha Lianmao; Zhang Caihong; Song Hailong; Ren Xiaona; Han Yuhu; Zhang Aiming; Chu Taiwei

    2003-01-01

    This paper reports quality control (QC) for the measurement of soil samples containing 237 Np and 241 Am as radiotracers in migration test of transuranic nuclides. All of the QC were done independently by the QA members of analytical work. It mainly included checking 5%-10% of the total analyzed samples; preparing blank samples, blind replicate sample and spiked samples used as quality control samples to check the quality of analytical work

  17. PET imaging of HSV1-tk mutants with acquired specificity toward pyrimidine- and acycloguanosine-based radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Likar, Yury; Dobrenkov, Konstantin; Olszewska, Malgorzata; Shenker, Larissa; Hricak, Hedvig; Ponomarev, Vladimir [Memorial Sloan-Kettering Cancer Center, Molecular Imaging Laboratory, Department of Radiology, New York, NY (United States); Cai, Shangde [Memorial Sloan-Kettering Cancer Center, Radiochemistry/Cyclotron Core Facility, New York, NY (United States)

    2009-08-15

    The aim of this study was to create an alternative mutant of the herpes simplex virus type 1 thymidine kinase (HSV1-tk) reporter gene with reduced phosphorylation capacity for acycloguanosine derivatives, but not pyrimidine-based compounds that will allow for successful PET imaging. A new mutant of HSV1-tk reporter gene, suitable for PET imaging using pyrimidine-based radiotracers, was developed. The HSV1-tk mutant contains an arginine-to-glutamine substitution at position 176 (HSV1-R176Qtk) of the nucleoside binding region of the enzyme. The mutant-gene product showed favorable enzymatic characteristics toward pyrimidine-based nucleosides, while exhibiting reduced activity with acycloguanosine derivatives. In order to enhance HSV1-R176Qtk reporter activity with pyrimidine-based radiotracers, we introduced the R176Q substitution into the more active HSV1-sr39tk mutant. U87 human glioma cells transduced with the HSV1-R176Qsr39tk double mutant reporter gene showed high {sup 3}H-FEAU pyrimidine nucleoside and low {sup 3}H-penciclovir acycloguanosine analog uptake in vitro. PET imaging also demonstrated high {sup 18}F-FEAU and low {sup 18}F-FHBG accumulation in HSV1-R176Qsr39tk+ xenografts. The feasibility of imaging two independent nucleoside-specific HSV1-tk mutants in the same animal with PET was demonstrated. Two opposite xenografts expressing the HSV1-R176Qsr39tk reporter gene and the previously described acycloguanosine-specific mutant of HSV1-tk, HSV1-A167Ysr39tk reporter gene, were imaged using a short-lived pyrimidine-based {sup 18}F-FEAU and an acycloguanosine-based {sup 18}F-FHBG radiotracer, respectively, administered on 2 consecutive days. We conclude that in combination with acycloguanosine-specific HSV1-A167Ysr39tk reporter gene, a HSV1-tk mutant containing the R176Q substitution could be used for PET imaging of two different cell populations or concurrent molecular biological processes in the same living subject. (orig.)

  18. Technetium-99 behavior in the terrestrial environment. Field observations and radiotracer experiments

    International Nuclear Information System (INIS)

    Tagami, Keiko

    2003-01-01

    Obtaining data on 99 Tc in the rice paddy field environment is important because Tc is a redox sensitive element. The behavior of Tc is expected to be different under upland field and rice paddy field conditions since the redox conditions in the soil environment differ. However, most of the data on the nuclide behavior in soil were obtained under upland field conditions. To understand the global fallout 99 Tc distributions in soil samples collected in Japan, a simple and rapid separation method was developed in order to determine low-levels of 99 Tc in soil samples by an inductively coupled plasma mass spectrometry. Also, radiotracer experiments using soils under aerobic and anaerobic conditions were carried out to clarify the Tc behavior under paddy field conditions. The results of determination of global fallout 99 Tc in Japanese soils indicated that the radionuclide had been accumulating in rice paddy fields. The mechanisms can be explained by the immobilization of Tc in soil under anaerobic conditions. From the radiotracer experiments, it was clear that under waterlogged conditions, the highly mobile TcO 4 - in soil was readily changed to other immobilized forms, such as TcO 2 , TcS 2 and organically bound forms. To this immobilization, the microbial activity seemed to have an important role in Tc sorption reactions. When the soil, which was once kept in anaerobic conditions, was air-dried again and kept in aerobic conditions, the chemical forms of immobilized Tc did not change remarkably. Interestingly, the similar Tc behavior was observed in a real wet forest near the Chernobyl Reactor. (author)

  19. Digital tomosynthesis using a 35 mm X-ray cinematogram during an isocentric rotational motion

    International Nuclear Information System (INIS)

    Maeda, Hirofumi; Aikawa, Hisayuki; Maeda, Tohru; Miyake, Hidetoshi; Sugahara, Tetsuo.

    1988-01-01

    Digital tomosynthesis is performed using a 35 mm X-ray cinematogram obtained during an isocentric rotational motion of the cineangiographic apparatus. Formula of image shift for digital tomosynthesis using an isocentric rotational motion is induced by perspective projection and affine transformation. Images of desired layer are aligned at the same point in the image processor and summed. Resultant final image is displayed in sharp focus. We can set tomosynthetic factors on any desired projection, sweep angle and depth as concerns digital tomosynthesis using an isocentric rotational motion. Especially we emphasize that tomosynthesis tilted for central axis of isocentric rotational motion can be obtained, using shear transformation of image in the image processor. (author)

  20. Subgrain Rotation Behavior in Sn3.0Ag0.5Cu-Sn37Pb Solder Joints During Thermal Shock

    Science.gov (United States)

    Han, Jing; Tan, Shihai; Guo, Fu

    2018-01-01

    Ball grid array (BGA) samples were soldered on a printed circuit board with Sn37Pb solder paste to investigate the recrystallization induced by subgrain rotation during thermal shock. The composition of the solder balls was Sn3.0Ag0.5Cu-Sn37Pb, which comprised mixed solder joints. The BGA component was cross-sectioned before thermal shock. The microstructure and grain orientations were obtained by a scanning electron microscope equipped with an electron back-scattered diffraction system. Two mixed solder joints at corners of the BGA component were selected as the subjects. The results showed that recrystallization occurred at the corner of the solder joints after 200 thermal shock cycles. The recrystallized subgrains had various new grain orientations. The newly generated grain orientations were closely related to the initial grain orientations, which indicated that different subgrain rotation behaviors could occur in one mixed solder joint with the same initial grain orientation. When the misorientation angles were very small, the rotation axes were about Sn [100], [010] and [001], as shown by analyzing the misorientation angles and subgrain rotation axes, while the subgrain rotation behavior with large misorientation angles in the solder joints was much more complicated. As Pb was contained in the solder joints and the stress was concentrated on the corner of the mixed solder joints, concaves and cracks were formed. When the adjacent recrystallized subgrains were separated, and the process of the continuous recrystallization was limited.

  1. Investigation of growth and characterization of nanostructured CuIn5S8 thin films produced by glancing angle deposition

    International Nuclear Information System (INIS)

    Sinaoui, A.; Chaffar-Akkari, F.; Gallas, B.; Demaille, D.; Kanzari, M.

    2015-01-01

    Ternary chalcogenide of copper and indium (CuIn 5 S 8 ) thin films were grown by thermal evaporation method using GLancing Angle Deposition (GLAD) technique. The samples were prepared under different incident angles (α = 0°, 40°, 60° and 85° measured from the normal to the substrate surface) with a substrate rotation of 2 rpm. X-ray diffraction, scanning electron microscopy, and ultraviolet–visible-infrared spectra are employed to characterize the microstructure and optical properties of the CuIn 5 S 8 thin films deposited by this technique. Under the GLAD conditions, we demonstrate that with substrate rotation, the columns were grown vertically due to the shadowing symmetry. The optical constants of the deposited films were determined from the analysis of transmission and reflection data. The results show that the refractive index and the thickness were decreased as α rises from 0° to 85° while the porosity and the Urbach energy were increased with increasing of the incident angle. The minimum refractive index is found to be 2.03 for the helical CuIn 5 S 8 film deposited at an angle of 85° and the Urbach energy was found to increase from 0.29 to 0.5 eV as α rises from 0° to 85°. Such changes of the optical behaviors are correlated with changes of the microstructure, especially a porous architecture which is favored for high incident angle. These properties exhibit potential for use in applications such as photonic crystals, graded index optical filters, and birefrigent omnidirectional reflectors. - Highlights: • GLancing angle deposition technique was employed to prepare CuIn 5 S 8 thin films. • CuIn 5 S 8 films exhibit a spinel structure with a preferred orientation along 311. • With substrate rotation, the columns were grown vertically due to shadowing symmetry. • The refractive index decreases with increasing glancing angle deposition. • Variations of the optical behaviors were correlated to the highly porous structure

  2. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  3. ROTATION AND MAGNETIC ACTIVITY IN A SAMPLE OF M-DWARFS

    International Nuclear Information System (INIS)

    Browning, Matthew K.; Basri, Gibor; Marcy, Geoffrey W.; Zhang Jiahao; West, Andrew A.

    2010-01-01

    We have analyzed the rotational broadening and chromospheric activity in a sample of 123 M-dwarfs, using spectra taken at the W.M. Keck Observatory as part of the California Planet Search program. We find that only seven of these stars are rotating more rapidly than our detection threshold of v sin i ∼ 2.5 km s -1 . Rotation appears to be more common in stars later than M3 than in the M0-M2.5 mass range: we estimate that less than 10% of early-M stars are detectably rotating, whereas roughly a third of those later than M4 show signs of rotation. These findings lend support to the view that rotational braking becomes less effective in fully convective stars. By measuring the equivalent widths of the Ca II H and K lines for the stars in our sample, and converting these to approximate L Ca /L bol measurements, we also provide constraints on the connection between rotation and magnetic activity. Measurable rotation is a sufficient, but not necessary condition for activity in our sample: all the detectable rotators show strong Ca II emission, but so too do a small number of non-rotating stars, which we presume may lie at high inclination angles relative to our line of sight. Our data are consistent with a 'saturation-type' rotation-activity relationship, with activity roughly independent of rotation above a threshold velocity of less than 6 km s -1 . We also find weak evidence for a 'gap' in L Ca /L bol between a highly active population of stars, which typically are detected as rotators, and another much less active group.

  4. Contact angle hysteresis and motion behaviors of a water nano-droplet on suspended graphene under temperature gradient

    Science.gov (United States)

    Foroutan, Masumeh; Fatemi, S. Mahmood; Esmaeilian, Farshad; Fadaei Naeini, Vahid; Baniassadi, Majid

    2018-05-01

    In the present work, the effect of temperature gradient on the behavior of a water nano-droplet resting on a suspended graphene was studied based on a non-equilibrium molecular dynamics simulation. The acquired results indicate that the applied temperature gradient to the suspended graphene drives the water nano-droplet to the colder region. The droplet accelerates its motion toward the cold reservoir as the temperature gradient is increased. In addition to the translational motion of the nano-droplet, the vortical motion of the water molecules was also observed. Contact angle analysis was also utilized to describe the directional motion of the nano-droplet. The translational motion of the droplet leads to the estimation of contact angle hysteresis through advancing and receding contact angles while the rotational motion resulted in the advancing and receding fronts being switched with one another through the simulation. The average displacement vector of the water molecules shows that parts of the droplet seem to stagnate while other parts rotate around them. The reason behind this particular behavior was studied based on interaction energy contours between a water molecule and the suspended graphene. The obtained data indicate that the rotational motion is in agreement with the migration of the water molecules to low interaction energy regions in order to avoid high interaction energy areas.

  5. Extraction of the mixture 99mTcO4- tributilfosfato- 30% 16% trioctylamine in cyclohexane evaluation of radiotracer obtained

    International Nuclear Information System (INIS)

    Ortega Pijeira, Martha Sahyli; Dominguez Catasus, Judith; Martinez Baez, Ernesto; Borroto Portela, Jorge

    2014-01-01

    Tracer technology plays an important role in industry development and has been widely used to optimize process, solve problems and improve product quality. In the last years Cuban scientific have studied the 99m TcO 4 - , eluted from 99 Mo/ 99m Tc generator, extraction with the mixture 30 % tributylphosphate -16 % trioctylamine in cyclohexane, in order to get an organic radiotracer. In this paper, the influence on 99m TcO 4 - extraction of stirring speed, contact time and NaCl concentration were studied. The extractant's role was also studied and, the tracer's homogeneity in diesel, special gasoline and Venezuelan oils was evaluated to normal pressure and temperature. The obtained outcomes showed that the NaCl concentration only influences on the extraction process when it is less than 0.17 %. Furthermore, the employed mixture's synergism was noticed and, could be conclude that, the obtained tracer is a physical radiotracer for the used industrial supports to 95 % trustworthy

  6. Rotational dynamics in supercooled water from nuclear spin relaxation and molecular simulations.

    Science.gov (United States)

    Qvist, Johan; Mattea, Carlos; Sunde, Erik P; Halle, Bertil

    2012-05-28

    Structural dynamics in liquid water slow down dramatically in the supercooled regime. To shed further light on the origin of this super-Arrhenius temperature dependence, we report high-precision (17)O and (2)H NMR relaxation data for H(2)O and D(2)O, respectively, down to 37 K below the equilibrium freezing point. With the aid of molecular dynamics (MD) simulations, we provide a detailed analysis of the rotational motions probed by the NMR experiments. The NMR-derived rotational correlation time τ(R) is the integral of a time correlation function (TCF) that, after a subpicosecond librational decay, can be described as a sum of two exponentials. Using a coarse-graining algorithm to map the MD trajectory on a continuous-time random walk (CTRW) in angular space, we show that the slowest TCF component can be attributed to large-angle molecular jumps. The mean jump angle is ∼48° at all temperatures and the waiting time distribution is non-exponential, implying dynamical heterogeneity. We have previously used an analogous CTRW model to analyze quasielastic neutron scattering data from supercooled water. Although the translational and rotational waiting times are of similar magnitude, most translational jumps are not synchronized with a rotational jump of the same molecule. The rotational waiting time has a stronger temperature dependence than the translation one, consistent with the strong increase of the experimentally derived product τ(R) D(T) at low temperatures. The present CTRW jump model is related to, but differs in essential ways from the extended jump model proposed by Laage and co-workers. Our analysis traces the super-Arrhenius temperature dependence of τ(R) to the rotational waiting time. We present arguments against interpreting this temperature dependence in terms of mode-coupling theory or in terms of mixture models of water structure.

  7. Anteroposterior glide versus rotating platform low contact stress (LCS knee arthroplasty: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Wynn-Jones Charles

    2007-08-01

    Full Text Available Abstract Background Fifty thousand knee replacements are performed annually in the UK at an estimated cost of £150 million. Post-operative improvement depends on a number of factors including implant design and patient associated factors. To our knowledge there are no published study's comparing the results of AP glide and rotating platform designs of LCS knee arthroplasty. Therefore we feel that a study is required to investigate and compare the effects of two types of LCS total knee arthroplasty on joint proprioception and range of motion. Methods/Design Patients will be randomised to receive either a LCS AP glide or Rotating platform prosthesis. Clinical scores (Oxford knee score, American knee society score, EuroQol, range of motion and proprioception will be assessed prior to and at 3,6, 12 and 24 months after the operation. Proprioception will be assessed in terms of absolute error angle (mean difference between the target angle and the response angle. Knee angles will be measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak that detects positions of sensors placed on the test limb. Student's t-test will be used to compare the mean of two groups. Discussion Evidence is lacking concerning the best prosthesis to use for patients undergoing total knee replacement. This pragmatic randomised trial will test the null hypothesis that anteroposterior glide LCS knee arthroplasty does not result in better post operative knee motion and proprioception as compared to rotating platform LCS knee. Trial Registration ISRCTN52943804

  8. Angle Dependence of the Orbital Magnetoresistance in Bismuth

    Directory of Open Access Journals (Sweden)

    Aurélie Collaudin

    2015-06-01

    Full Text Available We present an extensive study of angle-dependent transverse magnetoresistance in bismuth, with a magnetic field perpendicular to the applied electric current and rotating in three distinct crystallographic planes. The observed angular oscillations are confronted with the expectations of semiclassic transport theory for a multivalley system with anisotropic mobility and the agreement allows us to quantify the components of the mobility tensor for both electrons and holes. A quadratic temperature dependence is resolved. As Hartman argued long ago, this indicates that inelastic resistivity in bismuth is dominated by carrier-carrier scattering. At low temperature and high magnetic field, the threefold symmetry of the lattice is suddenly lost. Specifically, a 2π/3 rotation of magnetic field around the trigonal axis modifies the amplitude of the magnetoresistance below a field-dependent temperature. By following the evolution of this anomaly as a function of temperature and magnetic field, we map the boundary in the (field, temperature plane separating two electronic states. In the less symmetric state, confined to low temperature and high magnetic field, the three Dirac valleys cease to be rotationally invariant. We discuss the possible origins of this spontaneous valley polarization, including a valley-nematic scenario.

  9. A simple and efficient in vitro method for metabolism studies of radiotracers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang-Yoon; Choe, Yearn Seong E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Dong Hyun; Park, Bok-Nam; Kim, Sang Eun; Choi, Yong; Lee, Kyung-Han; Lee, Jeewoo E-mail: yschoe@samsung.co.krjeewoo@snu.ac.kr; Kim, Byung-Tae

    2001-05-01

    In vitro metabolism of acetylcholinesterase inhibitors containing 3-[{sup 18}F]fluoromethylbenzyl- ([{sup 18}F]1) and 4-[{sup 18}F]fluorobenzyl-piperidine moieties ([{sup 18}F]2) was studied and compared with the in vivo metabolism. Defluorination of the [{sup 18}F]1 mainly occurred to generate [{sup 18}F]fluoride ion both in vitro and in vivo. In contrast, the [{sup 18}F]2 was converted into an unknown polar metabolite in both metabolism methods and another metabolite, 4-[{sup 18}F]fluorobenzoic acid in vitro. These results demonstrated that the in vitro method can be used to predict the in vivo metabolism of both radiotracers.

  10. The rotational barrier in ethane: a molecular orbital study.

    Science.gov (United States)

    Quijano-Quiñones, Ramiro F; Quesadas-Rojas, Mariana; Cuevas, Gabriel; Mena-Rejón, Gonzalo J

    2012-04-20

    The energy change on each Occupied Molecular Orbital as a function of rotation about the C-C bond in ethane was studied using the B3LYP, mPWB95 functional and MP2 methods with different basis sets. Also, the effect of the ZPE on rotational barrier was analyzed. We have found that σ and π energies contribution stabilize a staggered conformation. The σ(s) molecular orbital stabilizes the staggered conformation while the stabilizes the eclipsed conformation and destabilize the staggered conformation. The π(z) and molecular orbitals stabilize both the eclipsed and staggered conformations, which are destabilized by the π(v) and molecular orbitals. The results show that the method of calculation has the effect of changing the behavior of the energy change in each Occupied Molecular Orbital energy as a function of the angle of rotation about the C-C bond in ethane. Finally, we found that if the molecular orbital energy contribution is deleted from the rotational energy, an inversion in conformational preference occurs.

  11. The Rotational Barrier in Ethane: A Molecular Orbital Study

    Directory of Open Access Journals (Sweden)

    Gonzalo J. Mena-Rejón

    2012-04-01

    Full Text Available The energy change on each Occupied Molecular Orbital as a function of rotation about the C-C bond in ethane was studied using the B3LYP, mPWB95 functional and MP2 methods with different basis sets. Also, the effect of the ZPE on rotational barrier was analyzed. We have found that σ and π energies contribution stabilize a staggered conformation. The σs molecular orbital stabilizes the staggered conformation while the  stabilizes the eclipsed conformation and destabilize the staggered conformation. The πz and  molecular orbitals stabilize both the eclipsed and staggered conformations, which are destabilized by the πv and  molecular orbitals. The results show that the method of calculation has the effect of changing the behavior of the energy change in each Occupied Molecular Orbital energy as a function of the angle of rotation about the C–C bond in ethane. Finally, we found that if the molecular orbital energy contribution is deleted from the rotational energy, an inversion in conformational preference occurs.

  12. Study of wastewater treatment plants efficiency using radiotracers

    International Nuclear Information System (INIS)

    Dawi, W. D. A.

    2010-11-01

    This study was performed to investigate and diagnose hydrodynamic behavior of the Military Hospital wastewater treatment plant. The plant comprises two units of treatment, each of them has a separate system. The investigation was carried out using ''1''3''1I as a radiotracer. The concept of residence time distribution (RTD) was used to investigate the efficiency of the aeration tanks, secondary clarifiers and chlorine tanks. Preliminary treatment and modeling of the trace data was performed using two software package applied by the International Atomic Energy Agency (IAEA) namely 4621 counter version 1.0.0 and RTD software. Plug flow pattern (parallel flow) was detected in the aeration tank and secondary clarifier of system 1 in one unit, while no homogeneous mixing was observed in the chlorine tank. Short - circuiting (by - passing) was evident in the aeration tank of system 2 in the other unit, which significantly reduced the operating efficiency. The percentage of dead volumes clearly suggests that the aeration tank and secondary clarifier were well utilized in the whole plant. (Author)

  13. Neural substrates of view-invariant object recognition developed without experiencing rotations of the objects.

    Science.gov (United States)

    Okamura, Jun-Ya; Yamaguchi, Reona; Honda, Kazunari; Wang, Gang; Tanaka, Keiji

    2014-11-05

    One fails to recognize an unfamiliar object across changes in viewing angle when it must be discriminated from similar distractor objects. View-invariant recognition gradually develops as the viewer repeatedly sees the objects in rotation. It is assumed that different views of each object are associated with one another while their successive appearance is experienced in rotation. However, natural experience of objects also contains ample opportunities to discriminate among objects at each of the multiple viewing angles. Our previous behavioral experiments showed that after experiencing a new set of object stimuli during a task that required only discrimination at each of four viewing angles at 30° intervals, monkeys could recognize the objects across changes in viewing angle up to 60°. By recording activities of neurons from the inferotemporal cortex after various types of preparatory experience, we here found a possible neural substrate for the monkeys' performance. For object sets that the monkeys had experienced during the task that required only discrimination at each of four viewing angles, many inferotemporal neurons showed object selectivity covering multiple views. The degree of view generalization found for these object sets was similar to that found for stimulus sets with which the monkeys had been trained to conduct view-invariant recognition. These results suggest that the experience of discriminating new objects in each of several viewing angles develops the partially view-generalized object selectivity distributed over many neurons in the inferotemporal cortex, which in turn bases the monkeys' emergent capability to discriminate the objects across changes in viewing angle. Copyright © 2014 the authors 0270-6474/14/3415047-13$15.00/0.

  14. Linear analysis of rotationally invariant, radially variant tomographic imaging systems

    International Nuclear Information System (INIS)

    Huesmann, R.H.

    1990-01-01

    This paper describes a method to analyze the linear imaging characteristics of rotationally invariant, radially variant tomographic imaging systems using singular value decomposition (SVD). When the projection measurements from such a system are assumed to be samples from independent and identically distributed multi-normal random variables, the best estimate of the emission intensity is given by the unweighted least squares estimator. The noise amplification of this estimator is inversely proportional to the singular values of the normal matrix used to model projection and backprojection. After choosing an acceptable noise amplification, the new method can determine the number of parameters and hence the number of pixels that should be estimated from data acquired from an existing system with a fixed number of angles and projection bins. Conversely, for the design of a new system, the number of angles and projection bins necessary for a given number of pixels and noise amplification can be determined. In general, computing the SVD of the projection normal matrix has cubic computational complexity. However, the projection normal matrix for this class of rotationally invariant, radially variant systems has a block circulant form. A fast parallel algorithm to compute the SVD of this block circulant matrix makes the singular value analysis practical by asymptotically reducing the computation complexity of the method by a multiplicative factor equal to the number of angles squared

  15. Uptake of heavy metals by the marine algae Padina gymnospora from Sepetiba Bay (RJ, Brazil) through radiotracers

    International Nuclear Information System (INIS)

    Magalhaes, V.F. de.

    1991-01-01

    The accumulation and the loss of 210 Pb, 51 Cr and 65 Zn by the alga Padina gymnospora is studied through radiotracer experiments. The evaluation of the alga as a bio indicator of these heavy metals pollution is presented. The use of this seaweed species to study the transfer of Pb, Cr, and Zn through the food chain is discussed. (M.A.C.)

  16. Development of new folate-based PET radiotracers: preclinical evaluation of 68Ga-DOTA-folate conjugates

    International Nuclear Information System (INIS)

    Fani, Melpomeni; Maecke, Helmut R.; Wang, Xuejuan; Nicolas, Guillaume; Medina, Christelle; Raynal, Isabelle; Port, Marc

    2011-01-01

    A number of 111 In- and 99m Tc-folate-based tracers have been evaluated as diagnostic agents for imaging folate receptor (FR)-positive tumours. A 68 Ga-folate-based radiopharmaceutical would be of great interest, combining the advantages of PET technology and the availability of 68 Ga from a generator. The aim of the study was to develop a new 68 Ga-folate-based PET radiotracer. Two new DOTA-folate conjugates, named P3026 and P1254, were synthesized using the 1,2-diaminoethane and 3-{2-[2-(3-amino-propoxy)-ethoxy]-ethoxy}-propylamine as a spacer, respectively. Both conjugates were labelled with 67/68 Ga. Binding affinity, internalization and externalization studies were performed using the FR-positive KB cell line. Biodistribution and PET/CT imaging studies were performed in nude mice, on a folate-deficient diet, bearing KB and HT1080 (FR-negative) tumours, concurrently. The new radiotracers were evaluated comparatively to the reference molecule 111 In-DTPA-folate ( 111 In-P3139). The K d values of 67/68 Ga-P3026 (4.65 ± 0.82 nM) and 67/68 Ga-P1254 (4.27 ± 0.42 nM) showed high affinity for the FR. The internalization rate followed the order 67/68 Ga-P3026 > 67/68 Ga-P1254 > 111 In-P3139, while almost double cellular retention was found for 67/68 Ga-P3026 and 67/68 Ga-P1254, compared to 111 In-P3139. The biodistribution data of 67/68 Ga-DOTA-folates showed high and receptor-mediated uptake on the FR-positive tumours and kidneys, with no significant differences compared to 111 In-P3139. PET/CT images, performed with 68 Ga-P3026, showed high uptake in the kidneys and clear visualization of the FR-positive tumours. The DOTA-folate conjugates can be efficiently labelled with 68 Ga in labelling yields and specific activities which allow clinical application. The characteristics of the 67/68 Ga-DOTA-folates are comparable to 111 In-DTPA-folate, which has already been used in clinical trials, showing that the new conjugates are promising candidates as PET radiotracers

  17. Light intensity dependent optical rotation in azobenzene polymers

    Science.gov (United States)

    Ivanov, M.; Ilieva, D.; Petrova, T.; Dragostinova, V.; Todorov, T.; Nikolova, L.

    2006-05-01

    We investigate the self-induced rotation of the azimuth of light polarization ellipse in azobenzene polymers. It is initiated by the photoreorientation and ordering of the azobenzenes on illumination with elliptically polarized light resulting in the appearance of an optical axis whose direction is gradually rotated along the depth of the film. A macroscopic chiral structure is created with a pitch depending on light ellipticity and the photobirefringence ▵n in the successive layers of the film. In this work we make use of the fact that at elevated temperatures ▵n is very sensitive to light intensity. In our acrylic amorphous azobenzene polymer at temperatures 50-65°C the saturated values of ▵n are much higher for low intensity of the exciting light than for higher intensity. In this temperature range the polarization azimuth of monochromatic blue light with different intensity is rotated to a different angle after passing through the polymer film. This effect can be used for passive elements rotating the polarization azimuth depending on light intensity and for the formation of light beams with a space-variant polarization state.

  18. Dynamic Effects of the Earth's Rotation Caused by the Annual and Semi-Annual Cyclic Mass Redistribution of the Planet

    Directory of Open Access Journals (Sweden)

    M. Yu. Barkin

    2016-01-01

    Full Text Available The paper deals with development of the theory of perturbed rotational motion of a celestial body with variable geometry of the masses. Its main task is to study the impact of annual and semi-annual variations of the Earth's mass geometry (a component of its inertia tensor, as well as a component of its relative angular momentum, on the movement of the Earth's poles and its axial rotation. The body is considered to be a free (isolated, and the problem formulation corresponds to the classical Liouville problem on rotation of a variable body. Euler conical movement of the axially symmetric body with an arbitrary constant half-angle  is assumed as the unperturbed motion. In the classical theory of the Earth's rotation this angle is usually assumed to be zero.In the last 20 years, accuracy to determine the Earth rotation parameters owing to using methods of space geodesy and method of Very Long Baseline Interferometry (VLBI has increased by about three orders of magnitude and has made about  i.e., in angle measure it is about 10 - 20 arc-microseconds. According to experts, the theory of the Earth's rotation with such precision is not created yet. The paper is focused just on the new dynamic studies of the Earth rotation at a higher level of accuracy than has been done in previous studies, using a new approach to the problem, based on the new forms of the equations of motion (in the Andoyer variables and the analytical methods of perturbation theory (small parameter method.The problem of perturbed rotational motion with variable geometry and variable mass relative angular momentum in the first approximation is solved in Andoyer variables and projections of the angular velocity of the planet rotation. The analytical solution allows us to run applications to study dynamic effects from above factors for various bodies in the solar system, including the Earth. The solution allowed us to obtain the following parameters of the fundamental effects in the

  19. Evaluation of fault-normal/fault-parallel directions rotated ground motions for response history analysis of an instrumented six-story building

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2012-01-01

    According to regulatory building codes in United States (for example, 2010 California Building Code), at least two horizontal ground-motion components are required for three-dimensional (3D) response history analysis (RHA) of buildings. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHA analyses should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak responses of engineering demand parameters (EDPs) were obtained for rotation angles ranging from 0° through 180° for evaluating the FN/FP directions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

  20. Abnormal gastrointestinal accumulation of radiotracer by gastric bleeding during 99mTc-MDP bone scintigraphy

    International Nuclear Information System (INIS)

    Chun, Kyung A.; Lee, Sang Woo; Lee, Jae Tae; Lee, Kyu Bo

    1998-01-01

    We present a case in which a patient with acute hemorrhagic gastritis demonstrated abnormal gastrointestinal accumulation of radiotracer during 99m Tc-methylene diphosphonate (MDP) skeletal scintigraphy. A hemorrhagic gastritis was subsequently demonstrated by endoscopy. The mechanism for the intestinal localization of 99m Tc-MDP in this patients is not clear, but we guess that the extravasated blood containing the radiopharmaceutical cannot recirculate and stays at the bleeding site, so we can see the intestinal activity

  1. Optofluidic laser scanner based on a rotating liquid prism.

    Science.gov (United States)

    Kopp, Daniel; Lehmann, Lukas; Zappe, Hans

    2016-03-20

    We demonstrate an electrowetting-actuated optofluidic system based on a rotatable liquid prism implemented as a two-dimensional laser scanner. The system is fabricated through a novel technology using a patterned flexible polymeric foil on which a high density of electrodes is structured and which is subsequently inserted into a cylindrical housing. The resulting radial electrode array is used for electrowetting actuation of two fluids filled into the cylinder, which allows a controllable tilt and orientation of the planar liquid interface and thus represents a tunable rotating prism. Finite element simulations and subsequent experimental verification show that this highly planar and precisely positionable liquid/liquid interface may be actuated to a deflection angle of ±6.4°, with a standard deviation of ±0.18°, and rotated 360° about the vertical axis. Power consumption is limited to several microwatts, and switching times of several hundred milliseconds were determined.

  2. Steady particulate flows in a horizontal rotating cylinder

    Science.gov (United States)

    Yamane, K.; Nakagawa, M.; Altobelli, S. A.; Tanaka, T.; Tsuji, Y.

    1998-06-01

    Results of discrete element method (DEM) simulation and magnetic resonance imaging (MRI) experiments are compared for monodisperse granular materials flowing in a half-filled horizontal rotating cylinder. Because opacity is not a problem for MRI, a long cylinder with an aspect ratio ˜7 was used and the flow in a thin transverse slice near the center was studied. The particles were mustard seeds and the ratio of cylinder diameter to particle diameter was approximately 50. The parameters compared were dynamic angle of repose, velocity field in a plane perpendicular to the cylinder axis, and velocity fluctuations at rotation rates up to 30 rpm. The agreement between DEM and MRI was good when the friction coefficient and nonsphericity were adjusted in the simulation for the best fit.

  3. Glancing angle deposited Al-doped ZnO nanostructures with different structural and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, A., E-mail: yildizab@gmail.com [Department of Physics and Astronomy, University of Arkansas at Little Rock, Little Rock, AR 72204 (United States); Department of Energy Systems Engineering, Faculty of Engineering and Natural Sciences, Yıldırım Beyazıt University, Ankara (Turkey); Cansizoglu, H. [Department of Physics and Astronomy, University of Arkansas at Little Rock, Little Rock, AR 72204 (United States); Turkoz, M. [Department of Physics and Astronomy, University of Arkansas at Little Rock, Little Rock, AR 72204 (United States); Department of Electrical-Electronic Engineering, Faculty of Engineering, University of Karabuk, Karabuk (Turkey); Abdulrahman, R.; Al-Hilo, Alaa; Cansizoglu, M.F.; Demirkan, T.M.; Karabacak, T. [Department of Physics and Astronomy, University of Arkansas at Little Rock, Little Rock, AR 72204 (United States)

    2015-08-31

    Al-doped ZnO (AZO) nanostructure arrays with different shapes (tilted rods, vertical rods, spirals, and zigzags) were fabricated by utilizing glancing angle deposition (GLAD) technique in a DC sputter growth unit at room temperature. During GLAD, all the samples were tilted at an oblique angle of about 90° with respect to incoming flux direction. In order to vary the shapes of nanostructures, each sample was rotated at different speeds around the substrate normal axis. Rotation speed did not only affect the shape but also changed the microstructural and optical properties of GLAD AZO nanostructures. The experimental results reveal that GLAD AZO nanostructures of different shapes each have unique morphological, crystal structure, mechanical, and optical properties determined by scanning electron microscopy, X-ray diffraction, transmission, and reflectance measurements. Vertical nanorods display the largest grain size, minimum strain, lowest defect density, and highest optical transmittance compared to the other shapes. Growth dynamics of GLAD has been discussed to explain the dependence of structural and optical properties of nanostructures on the substrate rotation speed. - Highlights: • Al-doped ZnO (AZO) nanostructures with different shapes were fabricated. • They have unique morphological, crystal structure, and optical properties. • Vertical AZO nanorods show an enhanced optical transmittance.

  4. Geometry and evolution of low-angle normal faults (LANF) within a Cenozoic high-angle rift system, Thailand: Implications for sedimentology and the mechanisms of LANF development

    Science.gov (United States)

    Morley, Chris K.

    2009-10-01

    At least eight examples of large (5-35 km heave), low-angle normal faults (LANFs, 20°-30° dip) occur in the Cenozoic rift basins of Thailand and laterally pass into high-angle extensional fault systems. Three large-displacement LANFs are found in late Oligocene-Miocene onshore rift basins (Suphan Buri, Phitsanulok, and Chiang Mai basins), they have (1) developed contemporaneous with, or after the onset of, high-angle extension, (2) acted as paths for magma and associated fluids, and (3) impacted sedimentation patterns. Displacement on low-angle faults appears to be episodic, marked by onset of lacustrine conditions followed by axial progradation of deltaic systems that infilled the lakes during periods of low or no displacement. The Chiang Mai LANF is a low-angle (15°-25°), high-displacement (15-35 km heave), ESE dipping LANF immediately east of the late early Miocene Doi Inthanon and Doi Suthep metamorphic core complexes. Early Cenozoic transpressional crustal thickening followed by the northward motion of India coupled with Burma relative to east Burma and Thailand (˜40-30 Ma) caused migmatization and gneiss dome uplift in the late Oligocene of the core complex region, followed by LANF activity. LANF displacement lasted 4-6 Ma during the early Miocene and possibly transported a late Oligocene-early Miocene high-angle rift system 35 km east. Other LANFs in Thailand have lower displacements and no associated metamorphic core complexes. The three LANFs were initiated as low-angle faults, not by isostatic rotation of high-angle faults. The low-angle dips appear to follow preexisting low-angle fabrics (thrusts, shear zones, and other low-angle ductile foliations) predominantly developed during Late Paleozoic and early Paleogene episodes of thrusting and folding.

  5. Measurement of torsion angles of long finger bones using computed tomography

    International Nuclear Information System (INIS)

    Berthold, L.D.; Ishaque, N.; Mauermann, F.; Klose, K.J.; Boehringer, G.

    2001-01-01

    Objective: Rotational dislocation at the fracture site is a complication of long finger bone fractures of the metacarpals and phalanges. To evaluate such deformities, we performed CT of the articular surfaces of these bones to demonstrate the torsion angles. Design: We evaluated 10 pairs of cadaver hands. These were placed flat, with the bones of interest perpendicular to the gantry to acquire axial images. The torsion of the long bone axes was defined as the angle between a tangent positioned parallel to the proximal articular surface and a tangent parallel to the distal articular surface of individual bones. Results: The maximum difference between repeated measurements was 4 . Intraobserver differences measured between right and left hands are less than 3 . Conclusion: Side differences in torsion angles exceeding 3 are strongly suspicious of a malrotation after fracture. These measurements might help to plan derotational osteotomy and assess the results of therapy. (orig.)

  6. Controlling the anisotropy and domain structure with oblique deposition and substrate rotation

    Directory of Open Access Journals (Sweden)

    N. Chowdhury

    2014-02-01

    Full Text Available Effect of substrate rotation on anisotropy and domain structure for a thin ferromagnetic film has been investigated in this work. For this purpose Co films with 10 nm thickness have been prepared by sputtering with oblique angle of incidence for various substrate rotations. This method of preparation induces a uniaxial anisotropy due to shadow deposition effect. The magnetization reversal is studied by magneto-optic Kerr effect (MOKE based microscope in the longitudinal geometry. The Co films prepared by rotating the substrate with 10 and 20 rpm weakens the anisotropy but does not completely give isotropic films. But this leads to high dispersion in local grain anisotropy resulting in ripple and labyrinth domains. It is observed that the substrate rotation has moderate effect on uniaxial anisotropy but has significant effect on the magnetization reversal process and the domain structure.

  7. Helium/solid powder O-ring leakage correlation experiments using a radiotracer

    International Nuclear Information System (INIS)

    Bild, R.W.; Leisher, W.B.; Weissman, S.H.; Seya, M.

    1984-01-01

    UO 2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

  8. Sulfur and Iron Cycling in a Coastal Sediment - Radiotracer Studies and Seasonal Dynamics

    DEFF Research Database (Denmark)

    MOESLUND, L.; THAMDRUP, B.; JØRGENSEN, BB

    1994-01-01

    to 2 mm in the oxidized surface layer of the sediment. The radiotracer data were analyzed by a mathematical model which showed that, due to partial, rapid reoxidation of radioactive sulfide during incubation, the actual reduction rates in this layer were probably underestimated 5-fold. In the deeper......, sulfidic zone, measured rates appeared to be correct. Sulfate reduction followed the seasonal variation in temperature with maximum activity at 1-2 cm depth in late summer. In spite of its rapid production, free H2S was detectable in the porewater only below the depth of free Fe2+ at 6-7 cm throughout...

  9. Characterizing root activity of guava trees by radiotracer technique

    International Nuclear Information System (INIS)

    Purohit, A.G.; Mukherjee, S.K.

    1974-01-01

    The distribution pattern of root activity of 12-year-old trees of guava (Psidium guajava L.) was determined by radiotracer technique. 32 P soloution was injected into the soil at lateral distances of 120, 240 and 360 cm from the tree trunk at depths of 15,30,60 and 90 cm. The 32 P uptake by the tree was determined by leaf analysis. In the rainy season the root activity or 32 P uptake was greater near the soil surface and midway between the trunk and the drip-line. The root activity decreased with an increase in the depth and distance from trunk. These results compared well with the actual distribution of feeder roots as determined by the soil-auger method. In summer the roots near the surface become less active in 32 P absorption with a drcrease in surface soil moisture. A decrease in the root activity in the surface soil was accompanied by an increase in 32 P uptake from lower depths. (author)

  10. Modeling and Implementation of Multi-Position Non-Continuous Rotation Gyroscope North Finder

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2016-09-01

    Full Text Available Even when the Global Positioning System (GPS signal is blocked, a rate gyroscope (gyro north finder is capable of providing the required azimuth reference information to a certain extent. In order to measure the azimuth between the observer and the north direction very accurately, we propose a multi-position non-continuous rotation gyro north finding scheme. Our new generalized mathematical model analyzes the elements that affect the azimuth measurement precision and can thus provide high precision azimuth reference information. Based on the gyro’s principle of detecting a projection of the earth rotation rate on its sensitive axis and the proposed north finding scheme, we are able to deduct an accurate mathematical model of the gyro outputs against azimuth with the gyro and shaft misalignments. Combining the gyro outputs model and the theory of propagation of uncertainty, some approaches to optimize north finding are provided, including reducing the gyro bias error, constraining the gyro random error, increasing the number of rotation points, improving rotation angle measurement precision, decreasing the gyro and the shaft misalignment angles. According them, a north finder setup is built and the azimuth uncertainty of 18” is obtained. This paper provides systematic theory for analyzing the details of the gyro north finder scheme from simulation to implementation. The proposed theory can guide both applied researchers in academia and advanced practitioners in industry for designing high precision robust north finder based on different types of rate gyroscopes.

  11. Insight into Rotational Effects on a Wind Turbine Blade Using Navier–Stokes Computations

    Directory of Open Access Journals (Sweden)

    Iván Herráez

    2014-10-01

    Full Text Available Rotational effects are known to influence severely the aerodynamic performance of the inboard region of rotor blades. The underlying physical mechanisms are however far from being well understood. The present work addresses this problem using Reynolds averaged Navier–Stokes computations and experimental results of the MEXICO (Model Experiments in Controlled Conditions rotor. Four axisymmetric inflow cases with wind speeds ranging from pre-stall to post-stall conditions are computed and compared with pressure and particle image velocimetry (PIV experimental data, obtaining, in general, consistent results. At low angles of attack, the aerodynamic behavior of all of the studied blade sections resembles the one from the corresponding 2D airfoils. However, at high angles of attack, rotational effects lead to stall delay and/or lift enhancement at inboard positions. Such effects are shown to occur only in the presence of significant radial flows. Interestingly, the way in which rotational effects influence the aerodynamics of the MEXICO blades differs qualitatively in certain aspects from the descriptions found in the literature about this topic. The presented results provide new insights that are useful for the development of advanced and physically-sound correction models.

  12. DC conductivity of twisted bilayer graphene: Angle-dependent transport properties and effects of disorder

    Science.gov (United States)

    Andelković, M.; Covaci, L.; Peeters, F. M.

    2018-03-01

    The in-plane dc conductivity of twisted bilayer graphene is calculated using an expansion of the real-space Kubo-Bastin conductivity in terms of Chebyshev polynomials. We investigate within a tight-binding approach the transport properties as a function of rotation angle, applied perpendicular electric field, and vacancy disorder. We find that for high-angle twists, the two layers are effectively decoupled, and the minimum conductivity at the Dirac point corresponds to double the value observed in monolayer graphene. This remains valid even in the presence of vacancies, hinting that chiral symmetry is still preserved. On the contrary, for low twist angles, the conductivity at the Dirac point depends on the twist angle and is not protected in the presence of disorder. Furthermore, for low angles and in the presence of an applied electric field, we find that the chiral boundary states emerging between AB and BA regions contribute to the dc conductivity, despite the appearance of localized states in the AA regions. The results agree qualitatively with recent transport experiments in low-angle twisted bilayer graphene.

  13. Measurements of liquid phase residence time distributions in a pilot-scale continuous leaching reactor using radiotracer technique.

    Science.gov (United States)

    Pant, H J; Sharma, V K; Shenoy, K T; Sreenivas, T

    2015-03-01

    An alkaline based continuous leaching process is commonly used for extraction of uranium from uranium ore. The reactor in which the leaching process is carried out is called a continuous leaching reactor (CLR) and is expected to behave as a continuously stirred tank reactor (CSTR) for the liquid phase. A pilot-scale CLR used in a Technology Demonstration Pilot Plant (TDPP) was designed, installed and operated; and thus needed to be tested for its hydrodynamic behavior. A radiotracer investigation was carried out in the CLR for measurement of residence time distribution (RTD) of liquid phase with specific objectives to characterize the flow behavior of the reactor and validate its design. Bromine-82 as ammonium bromide was used as a radiotracer and about 40-60MBq activity was used in each run. The measured RTD curves were treated and mean residence times were determined and simulated using a tanks-in-series model. The result of simulation indicated no flow abnormality and the reactor behaved as an ideal CSTR for the range of the operating conditions used in the investigation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Vibrational Suspension of Light Sphere in a Tilted Rotating Cylinder with Liquid

    Directory of Open Access Journals (Sweden)

    Victor G. Kozlov

    2014-01-01

    Full Text Available The dynamics of a light sphere in a quickly rotating inclined cylinder filled with liquid under transversal vibrations is experimentally investigated. Due to inertial oscillations of the sphere relative to the cavity, its rotation velocity differs from the cavity one. The intensification of the lagging motion of a sphere and the excitation of the outstripping differential rotation are possible under vibrations. It occurs in the resonant areas where the frequency of vibrations coincides with the fundamental frequency of the system. The position of the sphere in the center of the cylinder could be unstable. Different velocities of the sphere are matched with its various quasistationary positions on the axis of rotating cavity. In tilted rotating cylinder, the axial component of the gravity force appears; however, the light sphere does not float to the upper end wall but gets the stable position at a definite distance from it. It makes possible to provide a vibrational suspension of the light sphere in filled with liquid cavity rotating around the vertical axis. It is found that in the wide range of the cavity inclination angles the sphere position is determined by the dimensionless velocity of body differential rotation.

  15. Dynamic PET scanning and compartmental model analysis to determine cellular level radiotracer distribution in vivo

    International Nuclear Information System (INIS)

    Smith, G.T.; Hubner, K.F.; Goodman, M.M.; Stubbs, J.B.

    1992-01-01

    Positron emission tomography (PET) has been used to measure tissue radiotracer concentration in vivo. Radiochemical distribution can be determined with compartmental model analysis. A two compartment model describes the kinetics of N-13 ammonia ( 13 NH 3 ) in the myocardium. The model consists of a vascular space, Q 1 and a space for 13 NH 3 bound within the tissue, Q 2 . Differential equations for the model can be written: X(t) = AX(t) + BU( t), Y(t)= CX(t)+ DU(t) (1) where X(t) is a column vector [Q 1 (t); Q 2 (t)], U(t) is the arterial input activity measured from the left ventricular blood pool, and Y(t) is the measured tissue activity using PET. Matrices A, B, C, and D are dependent on physiological parameters describing the kinetics of 13 NH 3 in the myocardium. Estimated parameter matrices in Equation 1 have been validated in dog experiments by measuring myocardial perfusion with dynamic PET scanning and intravenous injection of 13 NH 3 . Tracer concentrations for each compartment can be calculated by direct integration of Equation 1. If the cellular level distribution of each compartment is known, the concentration of tracer within the intracellular and extracellular space can be determined. Applications of this type of modeling include parameter estimation for measurement of physiological processes, organ level dosimetry, and determination of cellular radiotracer distribution

  16. Novel in situ radiotracer methods for the direct and indirect study of chromate adsorption on alumina

    International Nuclear Information System (INIS)

    Gancs, L.; Nemeth, Z.; Horanyi, G.

    2002-01-01

    Radiotracer methods, particularly the radiotracer thin foil method, provide unique possibility of in situ monitoring of chromate adsorption on powdered adsorbents. Two different versions of the thin foil method can be distinguished. In the direct method, the species to be studied is labelled and the radiation measured gives direct information on the adsorption of this species. In the indirect method, a different labelled indicator species is added to the system and the adsorption of this species is followed and the adsorption of the species to be studied is determined based on analysis of the competitive adsorption processes. Both methods were used in the present study. In the in situ methods, the radiation measured consists of two main parts, one coming from the solution background, the other originating from the adsorption layer. In the case of the thin foil method using isotopes emitting soft β - radiation or low energy X-ray the solution background is governed and minimised by self-absorption of the radiation. In the direct study we applied an experimental methodology based on the energy selective measurement of the characteristic K α,β X-radiation emitted by the 51 Cr-labelled chromate species, whereas 35 S-labelled sulphate ions were used as the indicator species in the indirect study. (P.A.)

  17. Polycrystalline (TbXY1-X)2O3 Faraday rotator.

    Science.gov (United States)

    Ikesue, Akio; Aung, Yan Lin; Makikawa, Shinji; Yahagi, Akira

    2017-11-01

    We have succeeded for the first time in synthesizing an optical grade (Tb X Y 1-X ) 2 O 3 (X=0.5-1.0) ceramic Faraday rotator, which greatly exceeds the basic characteristics of the commercial terbium gallium garnet (TGG) (Tb 3 Ga 5 O 12 ) crystal. The Faraday rotation angle increased as the Tb concentration increased, and the Verdet constant increased from 2.1 (82  rad T -1  m -1 at X=0.5) to 3.8 times (154  rad T -1  m -1 at X=1.0) than the TGG single crystal, which is regarded as highest class. Therefore, it is possible to minimize the Faraday rotator length and the magnet in building an optical isolator. It was also confirmed that its optical quality was very comparable to the commercial TGG crystal.

  18. Radiotracer techniques in mineral processing

    International Nuclear Information System (INIS)

    Przewlocki, K.

    1991-01-01

    The value of the smelter metal content in currently exploited polymetallic ores mostly does not exceed 2%. Before metallurgical treatment, ore must pass through the concentration process. The benefication process usually starts from the comminution of excavated material and terminates at the flotation and drying of the concentrate. These operations consume vast quantities of energy. To be economically justified, the process requires optimization and, if possible, automatic control. Radioactive tracers were found to be useful in the identification of particular technological subsystems and their subsequent optimization. A great deal of experience has been gathered in this field so far. The industrial radiotracer test (RTT) is carried out using very sensitive multidetector recording systems which have digital data acquisition capabilities. The optimization strategy consists of periodically adjusting technological process and set points of controlled variables according to certain improvement procedures. If computer facilities are available, data interpretation and calibration of the mathematical models describing the technical process itself can be performed on the spot. This significantly accelerates the whole procedure as RTT may be repeated for particular system configurations. The procedure of plant optimization by means of RTT is illustrated in the paper using the example of the copper ore enrichment process, assuming that it is representative of the whole mineral industry. Identification by RTT of the three main operations involved in the ore enrichment process, such as comminution, flotation and granular classification, is discussed in detail as particular case studies. In reference to this, it is also shown how the technological process can be adjusted to be most efficient. (author). 14 refs, 7 figs

  19. Principle and analysis of a rotational motion Fourier transform infrared spectrometer

    Science.gov (United States)

    Cai, Qisheng; Min, Huang; Han, Wei; Liu, Yixuan; Qian, Lulu; Lu, Xiangning

    2017-09-01

    Fourier transform infrared spectroscopy is an important technique in studying molecular energy levels, analyzing material compositions, and environmental pollutants detection. A novel rotational motion Fourier transform infrared spectrometer with high stability and ultra-rapid scanning characteristics is proposed in this paper. The basic principle, the optical path difference (OPD) calculations, and some tolerance analysis are elaborated. The OPD of this spectrometer is obtained by the continuously rotational motion of a pair of parallel mirrors instead of the translational motion in traditional Michelson interferometer. Because of the rotational motion, it avoids the tilt problems occurred in the translational motion Michelson interferometer. There is a cosine function relationship between the OPD and the rotating angle of the parallel mirrors. An optical model is setup in non-sequential mode of the ZEMAX software, and the interferogram of a monochromatic light is simulated using ray tracing method. The simulated interferogram is consistent with the theoretically calculated interferogram. As the rotating mirrors are the only moving elements in this spectrometer, the parallelism of the rotating mirrors and the vibration during the scan are analyzed. The vibration of the parallel mirrors is the main error during the rotation. This high stability and ultra-rapid scanning Fourier transform infrared spectrometer is a suitable candidate for airborne and space-borne remote sensing spectrometer.

  20. Numerical results in a vertical wind axis turbine with relative rotating blades

    Energy Technology Data Exchange (ETDEWEB)

    Bayeul-Laine, Annie-Claude; Dockter, Aurore; Simonet, Sophie; Bois, Gerard [Arts et Metiers PARISTECH (France)

    2011-07-01

    The use of wind energy to produce electricity through wind turbines has spread world-wide. The quantity of electricity produced is affected by numerous factors such as wind speed and direction and turbine design; the aim of this paper is to assess the influence of different blades on the performance of a turbine. This study was performed on a turbine in which the blades have a rotating movement, each around its own axis and around the turbine's axis. Unsteady simulations were carried out with several blade stagger angles and one wind speed and 2 different blade geometries were used for 4 rotational speeds. Results showed that the studied turbine gave better performance than vertical axis wind turbines and that blade sketch, blade speed ratios, and blade stagger angle were important influences on the performance. This study showed that this kind of turbine has the potential to achieve good performance but that further work needs to be done.