  1. Treatment planning in radiosurgery: parallel Monte Carlo simulation software

    Energy Technology Data Exchange (ETDEWEB)

    Scielzo, G [Galliera Hospitals, Genova (Italy). Dept. of Hospital Physics; Grillo Ruggieri, F [Galliera Hospitals, Genova (Italy) Dept. for Radiation Therapy; Modesti, M; Felici, R [Electronic Data System, Rome (Italy); Surridge, M [University of South Hampton (United Kingdom). Parallel Apllication Centre

    1995-12-01

    The main objective of this research was to evaluate the possibility of direct Monte Carlo simulation for accurate dosimetry with short computation time. We made us of: graphics workstation, linear accelerator, water, PMMA and anthropomorphic phantoms, for validation purposes; ionometric, film and thermo-luminescent techniques, for dosimetry; treatment planning system for comparison. Benchmarking results suggest that short computing times can be obtained with use of the parallel version of EGS4 that was developed. Parallelism was obtained assigning simulation incident photons to separate processors, and the development of a parallel random number generator was necessary. Validation consisted in: phantom irradiation, comparison of predicted and measured values good agreement in PDD and dose profiles. Experiments on anthropomorphic phantoms (with inhomogeneities) were carried out, and these values are being compared with results obtained with the conventional treatment planning system.

  2. Monte Carlo dose distributions for radiosurgery

    International Nuclear Information System (INIS)

    Perucha, M.; Leal, A.; Rincon, M.; Carrasco, E.

    2001-01-01

    The precision of Radiosurgery Treatment planning systems is limited by the approximations of their algorithms and by their dosimetrical input data. This fact is especially important in small fields. However, the Monte Carlo methods is an accurate alternative as it considers every aspect of particle transport. In this work an acoustic neurinoma is studied by comparing the dose distribution of both a planning system and Monte Carlo. Relative shifts have been measured and furthermore, Dose-Volume Histograms have been calculated for target and adjacent organs at risk. (orig.)

  3. Is Monte Carlo embarrassingly parallel?

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J. E. [Delft Univ. of Technology, Mekelweg 15, 2629 JB Delft (Netherlands); Delft Nuclear Consultancy, IJsselzoom 2, 2902 LB Capelle aan den IJssel (Netherlands)

    2012-07-01

    Monte Carlo is often stated as being embarrassingly parallel. However, running a Monte Carlo calculation, especially a reactor criticality calculation, in parallel using tens of processors shows a serious limitation in speedup and the execution time may even increase beyond a certain number of processors. In this paper the main causes of the loss of efficiency when using many processors are analyzed using a simple Monte Carlo program for criticality. The basic mechanism for parallel execution is MPI. One of the bottlenecks turn out to be the rendez-vous points in the parallel calculation used for synchronization and exchange of data between processors. This happens at least at the end of each cycle for fission source generation in order to collect the full fission source distribution for the next cycle and to estimate the effective multiplication factor, which is not only part of the requested results, but also input to the next cycle for population control. Basic improvements to overcome this limitation are suggested and tested. Also other time losses in the parallel calculation are identified. Moreover, the threading mechanism, which allows the parallel execution of tasks based on shared memory using OpenMP, is analyzed in detail. Recommendations are given to get the maximum efficiency out of a parallel Monte Carlo calculation. (authors)

  4. Is Monte Carlo embarrassingly parallel?

    International Nuclear Information System (INIS)

    Hoogenboom, J. E.

    2012-01-01

    Monte Carlo is often stated as being embarrassingly parallel. However, running a Monte Carlo calculation, especially a reactor criticality calculation, in parallel using tens of processors shows a serious limitation in speedup and the execution time may even increase beyond a certain number of processors. In this paper the main causes of the loss of efficiency when using many processors are analyzed using a simple Monte Carlo program for criticality. The basic mechanism for parallel execution is MPI. One of the bottlenecks turn out to be the rendez-vous points in the parallel calculation used for synchronization and exchange of data between processors. This happens at least at the end of each cycle for fission source generation in order to collect the full fission source distribution for the next cycle and to estimate the effective multiplication factor, which is not only part of the requested results, but also input to the next cycle for population control. Basic improvements to overcome this limitation are suggested and tested. Also other time losses in the parallel calculation are identified. Moreover, the threading mechanism, which allows the parallel execution of tasks based on shared memory using OpenMP, is analyzed in detail. Recommendations are given to get the maximum efficiency out of a parallel Monte Carlo calculation. (authors)

  5. Parallel Monte Carlo reactor neutronics

    International Nuclear Information System (INIS)

    Blomquist, R.N.; Brown, F.B.

    1994-01-01

    The issues affecting implementation of parallel algorithms for large-scale engineering Monte Carlo neutron transport simulations are discussed. For nuclear reactor calculations, these include load balancing, recoding effort, reproducibility, domain decomposition techniques, I/O minimization, and strategies for different parallel architectures. Two codes were parallelized and tested for performance. The architectures employed include SIMD, MIMD-distributed memory, and workstation network with uneven interactive load. Speedups linear with the number of nodes were achieved

  6. Parallel computing by Monte Carlo codes MVP/GMVP

    International Nuclear Information System (INIS)

    Nagaya, Yasunobu; Nakagawa, Masayuki; Mori, Takamasa

    2001-01-01

    General-purpose Monte Carlo codes MVP/GMVP are well-vectorized and thus enable us to perform high-speed Monte Carlo calculations. In order to achieve more speedups, we parallelized the codes on the different types of parallel computing platforms or by using a standard parallelization library MPI. The platforms used for benchmark calculations are a distributed-memory vector-parallel computer Fujitsu VPP500, a distributed-memory massively parallel computer Intel paragon and a distributed-memory scalar-parallel computer Hitachi SR2201, IBM SP2. As mentioned generally, linear speedup could be obtained for large-scale problems but parallelization efficiency decreased as the batch size per a processing element(PE) was smaller. It was also found that the statistical uncertainty for assembly powers was less than 0.1% by the PWR full-core calculation with more than 10 million histories and it took about 1.5 hours by massively parallel computing. (author)

  7. Parallel processing of Monte Carlo code MCNP for particle transport problem

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Kenji; Kawasaki, Takuji

    1996-06-01

    It is possible to vectorize or parallelize Monte Carlo codes (MC code) for photon and neutron transport problem, making use of independency of the calculation for each particle. Applicability of existing MC code to parallel processing is mentioned. As for parallel computer, we have used both vector-parallel processor and scalar-parallel processor in performance evaluation. We have made (i) vector-parallel processing of MCNP code on Monte Carlo machine Monte-4 with four vector processors, (ii) parallel processing on Paragon XP/S with 256 processors. In this report we describe the methodology and results for parallel processing on two types of parallel or distributed memory computers. In addition, we mention the evaluation of parallel programming environments for parallel computers used in the present work as a part of the work developing STA (Seamless Thinking Aid) Basic Software. (author)

  8. Initial Assessment of Parallelization of Monte Carlo Calculation using Graphics Processing Units

    International Nuclear Information System (INIS)

    Choi, Sung Hoon; Joo, Han Gyu

    2009-01-01

    Monte Carlo (MC) simulation is an effective tool for calculating neutron transports in complex geometry. However, because Monte Carlo simulates each neutron behavior one by one, it takes a very long computing time if enough neutrons are used for high precision of calculation. Accordingly, methods that reduce the computing time are required. In a Monte Carlo code, parallel calculation is well-suited since it simulates the behavior of each neutron independently and thus parallel computation is natural. The parallelization of the Monte Carlo codes, however, was done using multi CPUs. By the global demand for high quality 3D graphics, the Graphics Processing Unit (GPU) has developed into a highly parallel, multi-core processor. This parallel processing capability of GPUs can be available to engineering computing once a suitable interface is provided. Recently, NVIDIA introduced CUDATM, a general purpose parallel computing architecture. CUDA is a software environment that allows developers to manage GPU using C/C++ or other languages. In this work, a GPU-based Monte Carlo is developed and the initial assessment of it parallel performance is investigated

  9. Study on MPI/OpenMP hybrid parallelism for Monte Carlo neutron transport code

    International Nuclear Information System (INIS)

    Liang Jingang; Xu Qi; Wang Kan; Liu Shiwen

    2013-01-01

    Parallel programming with mixed mode of messages-passing and shared-memory has several advantages when used in Monte Carlo neutron transport code, such as fitting hardware of distributed-shared clusters, economizing memory demand of Monte Carlo transport, improving parallel performance, and so on. MPI/OpenMP hybrid parallelism was implemented based on a one dimension Monte Carlo neutron transport code. Some critical factors affecting the parallel performance were analyzed and solutions were proposed for several problems such as contention access, lock contention and false sharing. After optimization the code was tested finally. It is shown that the hybrid parallel code can reach good performance just as pure MPI parallel program, while it saves a lot of memory usage at the same time. Therefore hybrid parallel is efficient for achieving large-scale parallel of Monte Carlo neutron transport. (authors)

  10. Parallel MCNP Monte Carlo transport calculations with MPI

    International Nuclear Information System (INIS)

    Wagner, J.C.; Haghighat, A.

    1996-01-01

    The steady increase in computational performance has made Monte Carlo calculations for large/complex systems possible. However, in order to make these calculations practical, order of magnitude increases in performance are necessary. The Monte Carlo method is inherently parallel (particles are simulated independently) and thus has the potential for near-linear speedup with respect to the number of processors. Further, the ever-increasing accessibility of parallel computers, such as workstation clusters, facilitates the practical use of parallel Monte Carlo. Recognizing the nature of the Monte Carlo method and the trends in available computing, the code developers at Los Alamos National Laboratory implemented the message-passing general-purpose Monte Carlo radiation transport code MCNP (version 4A). The PVM package was chosen by the MCNP code developers because it supports a variety of communication networks, several UNIX platforms, and heterogeneous computer systems. This PVM version of MCNP has been shown to produce speedups that approach the number of processors and thus, is a very useful tool for transport analysis. Due to software incompatibilities on the local IBM SP2, PVM has not been available, and thus it is not possible to take advantage of this useful tool. Hence, it became necessary to implement an alternative message-passing library package into MCNP. Because the message-passing interface (MPI) is supported on the local system, takes advantage of the high-speed communication switches in the SP2, and is considered to be the emerging standard, it was selected

  11. Simulation of neutron transport equation using parallel Monte Carlo for deep penetration problems

    International Nuclear Information System (INIS)

    Bekar, K. K.; Tombakoglu, M.; Soekmen, C. N.

    2001-01-01

    Neutron transport equation is simulated using parallel Monte Carlo method for deep penetration neutron transport problem. Monte Carlo simulation is parallelized by using three different techniques; direct parallelization, domain decomposition and domain decomposition with load balancing, which are used with PVM (Parallel Virtual Machine) software on LAN (Local Area Network). The results of parallel simulation are given for various model problems. The performances of the parallelization techniques are compared with each other. Moreover, the effects of variance reduction techniques on parallelization are discussed

  12. Dose distribution close to metal implants in Gamma Knife Radiosurgery: A Monte Carlo study

    International Nuclear Information System (INIS)

    Cheung, Joel Y.C.; Yu, K.N.; Chan, Josie F.K.; Ho, Robert T.K.; Yu, C.P.

    2003-01-01

    Materials with high atomic numbers favor the occurrence of the photoelectric effect when they are irradiated with gamma rays. Therefore, the photoelectric effects of metal implants within the target regions in Gamma Knife Radiosurgery are worth studying. In the present work, Monte Carlo simulations using EGS4 were employed to investigate the resulting dose enhancements. A dose enhancement as high as 10% was observed close to a platinum implant along the x and y axes, while no significant dose enhancements were observed for silver, stainless steel 301, and titanium ones. A dose enhancement as high as 20% was observed close to the platinum implant along the z axis at the superior position of the metal-phantom interface and was 10% higher for other metal implants

  13. Application of OMEGA Monte Carlo codes for radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Ayyangar, Komanduri M.; Jiang, Steve B.

    1998-01-01

    The accuracy of conventional dose algorithms for radiosurgery treatment planning is limited, due to the inadequate consideration of the lateral radiation transport and the difficulty of acquiring accurate dosimetric data for very small beams. In the present paper, some initial work on the application of Monte Carlo method in radiation treatment planning in general, and in radiosurgery treatment planning in particular, has been presented. Two OMEGA Monte Carlo codes, BEAM and DOSXYZ, are used. The BEAM code is used to simulate the transport of particles in the linac treatment head and radiosurgery collimator. A phase space file is obtained from the BEAM simulation for each collimator size. The DOSXYZ code is used to calculate the dose distribution in the patient's body reconstructed from CT slices using the phase space file as input. The accuracy of OMEGA Monte Carlo simulation for radiosurgery dose calculation is verified by comparing the calculated and measured basic dosimetric data for several radiosurgery beams and a 4 x 4 cm 2 conventional beam. The dose distributions for three clinical cases are calculated using OMEGA codes as the dose engine for an in-house developed radiosurgery treatment planning system. The verification using basic dosimetric data and the dose calculation for clinical cases demonstrate the feasibility of applying OMEGA Monte Carlo code system to radiosurgery treatment planning. (author)

  14. Monte Carlo simulation applied to radiosurgery narrow beams using MCNP-4C

    International Nuclear Information System (INIS)

    Chaves, A.; Lopes, M.C.; Oliveira, C.

    2001-01-01

    Dose measurements for the narrow photon beams used in radiosurgery are complicated by the lack of electron equilibrium which is a requirement namely for ionometric methods. To overcome this difficulty the use of different dosimetric supports is strongly recommended in order to appreciate the influence of each type of detector. Monte Carlo simulation is another kind of tool to assess the details of the energy deposition phenomena in such narrow photon beams. In this study output factors and depth dose calculated by the Monte Carlo MCNP-4C code are presented and compared with experimental data measured with a diode, a Markus chamber, a 0.125 cc thimble chamber and a Pinpoint chamber. Simulated energy spectra for narrow beams are also presented in order to compare them with the reference 10 cm x 10 cm beam field size and thus discuss the different contributions of the absorbed energy in water, in each case. A detailed analysis on the photon energy spectra showed a slight decrease on the photon mean energy that can be explained by the increased scattering inside the additional collimators. Calculated and measured depth doses curves are in good agreement for most of the collimators. For the two smallest collimators some differences have been pointed and explained according to the characteristics of the detectors (author)

  15. A parallelization study of the general purpose Monte Carlo code MCNP4 on a distributed memory highly parallel computer

    International Nuclear Information System (INIS)

    Yamazaki, Takao; Fujisaki, Masahide; Okuda, Motoi; Takano, Makoto; Masukawa, Fumihiro; Naito, Yoshitaka

    1993-01-01

    The general purpose Monte Carlo code MCNP4 has been implemented on the Fujitsu AP1000 distributed memory highly parallel computer. Parallelization techniques developed and studied are reported. A shielding analysis function of the MCNP4 code is parallelized in this study. A technique to map a history to each processor dynamically and to map control process to a certain processor was applied. The efficiency of parallelized code is up to 80% for a typical practical problem with 512 processors. These results demonstrate the advantages of a highly parallel computer to the conventional computers in the field of shielding analysis by Monte Carlo method. (orig.)

  16. Load Balancing of Parallel Monte Carlo Transport Calculations

    International Nuclear Information System (INIS)

    Procassini, R J; O'Brien, M J; Taylor, J M

    2005-01-01

    The performance of parallel Monte Carlo transport calculations which use both spatial and particle parallelism is increased by dynamically assigning processors to the most worked domains. Since he particle work load varies over the course of the simulation, this algorithm determines each cycle if dynamic load balancing would speed up the calculation. If load balancing is required, a small number of particle communications are initiated in order to achieve load balance. This method has decreased the parallel run time by more than a factor of three for certain criticality calculations

  17. The vector and parallel processing of MORSE code on Monte Carlo Machine

    International Nuclear Information System (INIS)

    Hasegawa, Yukihiro; Higuchi, Kenji.

    1995-11-01

    Multi-group Monte Carlo Code for particle transport, MORSE is modified for high performance computing on Monte Carlo Machine Monte-4. The method and the results are described. Monte-4 was specially developed to realize high performance computing of Monte Carlo codes for particle transport, which have been difficult to obtain high performance in vector processing on conventional vector processors. Monte-4 has four vector processor units with the special hardware called Monte Carlo pipelines. The vectorization and parallelization of MORSE code and the performance evaluation on Monte-4 are described. (author)

  18. Dynamic Load Balancing of Parallel Monte Carlo Transport Calculations

    International Nuclear Information System (INIS)

    O'Brien, M; Taylor, J; Procassini, R

    2004-01-01

    The performance of parallel Monte Carlo transport calculations which use both spatial and particle parallelism is increased by dynamically assigning processors to the most worked domains. Since the particle work load varies over the course of the simulation, this algorithm determines each cycle if dynamic load balancing would speed up the calculation. If load balancing is required, a small number of particle communications are initiated in order to achieve load balance. This method has decreased the parallel run time by more than a factor of three for certain criticality calculations

  19. Random number generators for large-scale parallel Monte Carlo simulations on FPGA

    Science.gov (United States)

    Lin, Y.; Wang, F.; Liu, B.

    2018-05-01

    Through parallelization, field programmable gate array (FPGA) can achieve unprecedented speeds in large-scale parallel Monte Carlo (LPMC) simulations. FPGA presents both new constraints and new opportunities for the implementations of random number generators (RNGs), which are key elements of any Monte Carlo (MC) simulation system. Using empirical and application based tests, this study evaluates all of the four RNGs used in previous FPGA based MC studies and newly proposed FPGA implementations for two well-known high-quality RNGs that are suitable for LPMC studies on FPGA. One of the newly proposed FPGA implementations: a parallel version of additive lagged Fibonacci generator (Parallel ALFG) is found to be the best among the evaluated RNGs in fulfilling the needs of LPMC simulations on FPGA.

  20. Speed up of MCACE, a Monte Carlo code for evaluation of shielding safety, by parallel computer, (3)

    International Nuclear Information System (INIS)

    Takano, Makoto; Masukawa, Fumihiro; Naito, Yoshitaka; Onodera, Emi; Imawaka, Tsuneyuki; Yoda, Yoshihisa.

    1993-07-01

    The parallel computing of the MCACE code has been studied on two platforms; 1) Shared Memory Type Vector-Parallel Computer Monte-4 and 2) Networked Several Workstations. On the Monte-4, a disk-file has been allocated to collect all results computed by 4 CPUs in parallel, executing the copy of the MCACE code on each CPU. On the workstations under network environment, two parallel models have been evaluated; 1) a host-node model and 2) the model used on the Monte-4 where no software for parallelization has been employed but only standard FORTRAN language. The measurement of computing times has showed that speed up of about 3 times has been achieved by using 4 CPUs of the Monte-4. Further, connecting 4 workstations by network, the computing speed by parallelization has achieved faster than our scalar main frame computer, FACOM M-780. (author)

  1. Parallel Monte Carlo Search for Hough Transform

    Science.gov (United States)

    Lopes, Raul H. C.; Franqueira, Virginia N. L.; Reid, Ivan D.; Hobson, Peter R.

    2017-10-01

    We investigate the problem of line detection in digital image processing and in special how state of the art algorithms behave in the presence of noise and whether CPU efficiency can be improved by the combination of a Monte Carlo Tree Search, hierarchical space decomposition, and parallel computing. The starting point of the investigation is the method introduced in 1962 by Paul Hough for detecting lines in binary images. Extended in the 1970s to the detection of space forms, what came to be known as Hough Transform (HT) has been proposed, for example, in the context of track fitting in the LHC ATLAS and CMS projects. The Hough Transform transfers the problem of line detection, for example, into one of optimization of the peak in a vote counting process for cells which contain the possible points of candidate lines. The detection algorithm can be computationally expensive both in the demands made upon the processor and on memory. Additionally, it can have a reduced effectiveness in detection in the presence of noise. Our first contribution consists in an evaluation of the use of a variation of the Radon Transform as a form of improving theeffectiveness of line detection in the presence of noise. Then, parallel algorithms for variations of the Hough Transform and the Radon Transform for line detection are introduced. An algorithm for Parallel Monte Carlo Search applied to line detection is also introduced. Their algorithmic complexities are discussed. Finally, implementations on multi-GPU and multicore architectures are discussed.

  2. A Monte Carlo multiple source model applied to radiosurgery narrow photon beams

    International Nuclear Information System (INIS)

    Chaves, A.; Lopes, M.C.; Alves, C.C.; Oliveira, C.; Peralta, L.; Rodrigues, P.; Trindade, A.

    2004-01-01

    Monte Carlo (MC) methods are nowadays often used in the field of radiotherapy. Through successive steps, radiation fields are simulated, producing source Phase Space Data (PSD) that enable a dose calculation with good accuracy. Narrow photon beams used in radiosurgery can also be simulated by MC codes. However, the poor efficiency in simulating these narrow photon beams produces PSD whose quality prevents calculating dose with the required accuracy. To overcome this difficulty, a multiple source model was developed that enhances the quality of the reconstructed PSD, reducing also the time and storage capacities. This multiple source model was based on the full MC simulation, performed with the MC code MCNP4C, of the Siemens Mevatron KD2 (6 MV mode) linear accelerator head and additional collimators. The full simulation allowed the characterization of the particles coming from the accelerator head and from the additional collimators that shape the narrow photon beams used in radiosurgery treatments. Eight relevant photon virtual sources were identified from the full characterization analysis. Spatial and energy distributions were stored in histograms for the virtual sources representing the accelerator head components and the additional collimators. The photon directions were calculated for virtual sources representing the accelerator head components whereas, for the virtual sources representing the additional collimators, they were recorded into histograms. All these histograms were included in the MC code, DPM code and using a sampling procedure that reconstructed the PSDs, dose distributions were calculated in a water phantom divided in 20000 voxels of 1x1x5 mm 3 . The model accurately calculates dose distributions in the water phantom for all the additional collimators; for depth dose curves, associated errors at 2σ were lower than 2.5% until a depth of 202.5 mm for all the additional collimators and for profiles at various depths, deviations between measured

  3. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    International Nuclear Information System (INIS)

    Yip, Ho Yin; Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G.; Law, Maria Y.Y.

    2013-01-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time

  4. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Ho Yin, E-mail: hoyinyip@yahoo.com.hk [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G. [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Law, Maria Y.Y. [Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China)

    2013-07-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

  5. Parallel Monte Carlo simulation of aerosol dynamics

    KAUST Repository

    Zhou, K.

    2014-01-01

    A highly efficient Monte Carlo (MC) algorithm is developed for the numerical simulation of aerosol dynamics, that is, nucleation, surface growth, and coagulation. Nucleation and surface growth are handled with deterministic means, while coagulation is simulated with a stochastic method (Marcus-Lushnikov stochastic process). Operator splitting techniques are used to synthesize the deterministic and stochastic parts in the algorithm. The algorithm is parallelized using the Message Passing Interface (MPI). The parallel computing efficiency is investigated through numerical examples. Near 60% parallel efficiency is achieved for the maximum testing case with 3.7 million MC particles running on 93 parallel computing nodes. The algorithm is verified through simulating various testing cases and comparing the simulation results with available analytical and/or other numerical solutions. Generally, it is found that only small number (hundreds or thousands) of MC particles is necessary to accurately predict the aerosol particle number density, volume fraction, and so forth, that is, low order moments of the Particle Size Distribution (PSD) function. Accurately predicting the high order moments of the PSD needs to dramatically increase the number of MC particles. 2014 Kun Zhou et al.

  6. Parallelization of MCNP Monte Carlo neutron and photon transport code in parallel virtual machine and message passing interface

    International Nuclear Information System (INIS)

    Deng Li; Xie Zhongsheng

    1999-01-01

    The coupled neutron and photon transport Monte Carlo code MCNP (version 3B) has been parallelized in parallel virtual machine (PVM) and message passing interface (MPI) by modifying a previous serial code. The new code has been verified by solving sample problems. The speedup increases linearly with the number of processors and the average efficiency is up to 99% for 12-processor. (author)

  7. Crossing the mesoscale no-mans land via parallel kinetic Monte Carlo.

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Cardona, Cristina (San Diego State University); Webb, Edmund Blackburn, III; Wagner, Gregory John; Tikare, Veena; Holm, Elizabeth Ann; Plimpton, Steven James; Thompson, Aidan Patrick; Slepoy, Alexander (U. S. Department of Energy, NNSA); Zhou, Xiao Wang; Battaile, Corbett Chandler; Chandross, Michael Evan

    2009-10-01

    The kinetic Monte Carlo method and its variants are powerful tools for modeling materials at the mesoscale, meaning at length and time scales in between the atomic and continuum. We have completed a 3 year LDRD project with the goal of developing a parallel kinetic Monte Carlo capability and applying it to materials modeling problems of interest to Sandia. In this report we give an overview of the methods and algorithms developed, and describe our new open-source code called SPPARKS, for Stochastic Parallel PARticle Kinetic Simulator. We also highlight the development of several Monte Carlo models in SPPARKS for specific materials modeling applications, including grain growth, bubble formation, diffusion in nanoporous materials, defect formation in erbium hydrides, and surface growth and evolution.

  8. Implementation of a Monte Carlo algorithm for neutron transport on a massively parallel SIMD machine

    International Nuclear Information System (INIS)

    Baker, R.S.

    1992-01-01

    We present some results from the recent adaptation of a vectorized Monte Carlo algorithm to a massively parallel architecture. The performance of the algorithm on a single processor Cray Y-MP and a Thinking Machine Corporations CM-2 and CM-200 is compared for several test problems. The results show that significant speedups are obtainable for vectorized Monte Carlo algorithms on massively parallel machines, even when the algorithms are applied to realistic problems which require extensive variance reduction. However, the architecture of the Connection Machine does place some limitations on the regime in which the Monte Carlo algorithm may be expected to perform well

  9. Implementation of a Monte Carlo algorithm for neutron transport on a massively parallel SIMD machine

    International Nuclear Information System (INIS)

    Baker, R.S.

    1993-01-01

    We present some results from the recent adaptation of a vectorized Monte Carlo algorithm to a massively parallel architecture. The performance of the algorithm on a single processor Cray Y-MP and a Thinking Machine Corporations CM-2 and CM-200 is compared for several test problems. The results show that significant speedups are obtainable for vectorized Monte Carlo algorithms on massively parallel machines, even when the algorithms are applied to realistic problems which require extensive variance reduction. However, the architecture of the Connection Machine does place some limitations on the regime in which the Monte Carlo algorithm may be expected to perform well. (orig.)

  10. Massively parallel Monte Carlo for many-particle simulations on GPUs

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Joshua A.; Jankowski, Eric [Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Grubb, Thomas L. [Department of Materials Science and Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Engel, Michael [Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Glotzer, Sharon C., E-mail: sglotzer@umich.edu [Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Department of Materials Science and Engineering, University of Michigan, Ann Arbor, MI 48109 (United States)

    2013-12-01

    Current trends in parallel processors call for the design of efficient massively parallel algorithms for scientific computing. Parallel algorithms for Monte Carlo simulations of thermodynamic ensembles of particles have received little attention because of the inherent serial nature of the statistical sampling. In this paper, we present a massively parallel method that obeys detailed balance and implement it for a system of hard disks on the GPU. We reproduce results of serial high-precision Monte Carlo runs to verify the method. This is a good test case because the hard disk equation of state over the range where the liquid transforms into the solid is particularly sensitive to small deviations away from the balance conditions. On a Tesla K20, our GPU implementation executes over one billion trial moves per second, which is 148 times faster than on a single Intel Xeon E5540 CPU core, enables 27 times better performance per dollar, and cuts energy usage by a factor of 13. With this improved performance we are able to calculate the equation of state for systems of up to one million hard disks. These large system sizes are required in order to probe the nature of the melting transition, which has been debated for the last forty years. In this paper we present the details of our computational method, and discuss the thermodynamics of hard disks separately in a companion paper.

  11. Parallel Monte Carlo simulations on an ARC-enabled computing grid

    International Nuclear Information System (INIS)

    Nilsen, Jon K; Samset, Bjørn H

    2011-01-01

    Grid computing opens new possibilities for running heavy Monte Carlo simulations of physical systems in parallel. The presentation gives an overview of GaMPI, a system for running an MPI-based random walker simulation on grid resources. Integrating the ARC middleware and the new storage system Chelonia with the Ganga grid job submission and control system, we show that MPI jobs can be run on a world-wide computing grid with good performance and promising scaling properties. Results for relatively communication-heavy Monte Carlo simulations run on multiple heterogeneous, ARC-enabled computing clusters in several countries are presented.

  12. Monte Carlo calculations on a parallel computer using MORSE-C.G

    International Nuclear Information System (INIS)

    Wood, J.

    1995-01-01

    The general purpose particle transport Monte Carlo code, MORSE-C.G., is implemented on a parallel computing transputer-based system having MIMD architecture. Example problems are solved which are representative of the 3-principal types of problem that can be solved by the original serial code, namely, fixed source, eigenvalue (k-eff) and time-dependent. The results from the parallelized version of the code are compared in tables with the serial code run on a mainframe serial computer, and with an independent, deterministic transport code. The performance of the parallel computer as the number of processors is varied is shown graphically. For the parallel strategy used, the loss of efficiency as the number of processors is increased, is investigated. (author)

  13. Dosimetric calculations by Monte Carlo for treatments of radiosurgery with the Leksell Gamma Knife, homogeneous and non homogeneous cases

    International Nuclear Information System (INIS)

    Rojas C, E.L.; Lallena R, A.M.

    2004-01-01

    In this work dose profiles are calculated that are obtained modeling treatments of radiosurgery with the Leksell Gamma Knife. This was made with the simulation code Monte Carlo Penelope for an homogeneous mannequin and one not homogeneous. Its were carried out calculations with the irradiation focus coinciding with the center of the mannequin as in near areas to the bone interface. Each one of the calculations one carries out for the 4 skull treatment that it includes the Gamma Knife and using a model simplified of their 201 sources of 60 Co. It was found that the dose profiles differ of the order of 2% when the isocenter coincides with the center of the mannequin and they ascend to near 5% when the isocenter moves toward the skull. (Author)

  14. Monte Carlo simulation of the Leksell Gamma KnifeTM: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Moskvin, Vadim; Timmerman, Robert; DesRosiers, Colleen; Randall, Marcus; DesRosiers, Paul; Dittmer, Phil; Papiez, Lech

    2004-01-01

    The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife TM . The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan TM ) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan TM due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife TM for targets in the vicinity of air-filled cavities

  15. Implementation of a Monte Carlo simulation environment for fully 3D PET on a high-performance parallel platform

    CERN Document Server

    Zaidi, H; Morel, Christian

    1998-01-01

    This paper describes the implementation of the Eidolon Monte Carlo program designed to simulate fully three-dimensional (3D) cylindrical positron tomographs on a MIMD parallel architecture. The original code was written in Objective-C and developed under the NeXTSTEP development environment. Different steps involved in porting the software on a parallel architecture based on PowerPC 604 processors running under AIX 4.1 are presented. Basic aspects and strategies of running Monte Carlo calculations on parallel computers are described. A linear decrease of the computing time was achieved with the number of computing nodes. The improved time performances resulting from parallelisation of the Monte Carlo calculations makes it an attractive tool for modelling photon transport in 3D positron tomography. The parallelisation paradigm used in this work is independent from the chosen parallel architecture

  16. Monte Carlo simulation of the Leksell Gamma Knife{sup TM}: II. Effects of heterogeneous versus homogeneous media for stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moskvin, Vadim; Timmerman, Robert; DesRosiers, Colleen; Randall, Marcus; DesRosiers, Paul; Dittmer, Phil; Papiez, Lech [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, 535 Barnhill Dr, RT041, IN 46202-5289 (United States)

    2004-11-07

    The absence of electronic equilibrium in the vicinity of bone-tissue or air-tissue heterogeneity in the head can misrepresent deposited dose with treatment planning algorithms that assume all treatment volume as homogeneous media. In this paper, Monte Carlo simulation (PENELOPE) and measurements with a specially designed heterogeneous phantom were applied to investigate the effect of air-tissue and bone-tissue heterogeneity on dose perturbation with the Leksell Gamma Knife{sup TM}. The dose fall-off near the air-tissue interface caused by secondary electron disequilibrium leads to overestimation of dose by the vendor supplied treatment planning software (GammaPlan{sup TM}) at up to 4 mm from an interface. The dose delivered to the target area away from an air-tissue interface may be underestimated by up to 7% by GammaPlan{sup TM} due to overestimation of attenuation of photon beams passing through air cavities. While the underdosing near the air-tissue interface cannot be eliminated with any plug pattern, the overdosage due to under-attenuation of the photon beams in air cavities can be eliminated by plugging the sources whose beams intersect the air cavity. Little perturbation was observed next to bone-tissue interfaces. Monte Carlo results were confirmed by measurements. This study shows that the employed Monte Carlo treatment planning is more accurate for precise dosimetry of stereotactic radiosurgery with the Leksell Gamma Knife{sup TM} for targets in the vicinity of air-filled cavities.

  17. Parallelization of a Monte Carlo particle transport simulation code

    Science.gov (United States)

    Hadjidoukas, P.; Bousis, C.; Emfietzoglou, D.

    2010-05-01

    We have developed a high performance version of the Monte Carlo particle transport simulation code MC4. The original application code, developed in Visual Basic for Applications (VBA) for Microsoft Excel, was first rewritten in the C programming language for improving code portability. Several pseudo-random number generators have been also integrated and studied. The new MC4 version was then parallelized for shared and distributed-memory multiprocessor systems using the Message Passing Interface. Two parallel pseudo-random number generator libraries (SPRNG and DCMT) have been seamlessly integrated. The performance speedup of parallel MC4 has been studied on a variety of parallel computing architectures including an Intel Xeon server with 4 dual-core processors, a Sun cluster consisting of 16 nodes of 2 dual-core AMD Opteron processors and a 200 dual-processor HP cluster. For large problem size, which is limited only by the physical memory of the multiprocessor server, the speedup results are almost linear on all systems. We have validated the parallel implementation against the serial VBA and C implementations using the same random number generator. Our experimental results on the transport and energy loss of electrons in a water medium show that the serial and parallel codes are equivalent in accuracy. The present improvements allow for studying of higher particle energies with the use of more accurate physical models, and improve statistics as more particles tracks can be simulated in low response time.

  18. A multi-transputer system for parallel Monte Carlo simulations of extensive air showers

    International Nuclear Information System (INIS)

    Gils, H.J.; Heck, D.; Oehlschlaeger, J.; Schatz, G.; Thouw, T.

    1989-01-01

    A multiprocessor computer system has been brought into operation at the Kernforschungszentrum Karlsruhe. It is dedicated to Monte Carlo simulations of extensive air showers induced by ultra-high energy cosmic rays. The architecture consists of two independently working VMEbus systems each with a 68020 microprocessor as host computer and twelve T800 transputers for parallel processing. The two systems are linked via Ethernet for data exchange. The T800 transputers are equipped with 4 Mbyte RAM each, sufficient to run rather large codes. The host computers are operated under UNIX 5.3. On the transputers compilers for PARALLEL FORTRAN, C, and PASCAL are available. The simple modular architecture of this parallel computer reflects the single purpose for which it is intended. The hardware of the multiprocessor computer is described as well as the way how the user software is handled and distributed to the 24 working processors. The performance of the parallel computer is demonstrated by well-known benchmarks and by realistic Monte Carlo simulations of air showers. Comparisons with other types of microprocessors and with large universal computers are made. It is demonstrated that a cost reduction by more than a factor of 20 is achieved by this system as compared to universal computer. (orig.)

  19. A portable, parallel, object-oriented Monte Carlo neutron transport code in C++

    International Nuclear Information System (INIS)

    Lee, S.R.; Cummings, J.C.; Nolen, S.D.

    1997-01-01

    We have developed a multi-group Monte Carlo neutron transport code using C++ and the Parallel Object-Oriented Methods and Applications (POOMA) class library. This transport code, called MC++, currently computes k and α-eigenvalues and is portable to and runs parallel on a wide variety of platforms, including MPPs, clustered SMPs, and individual workstations. It contains appropriate classes and abstractions for particle transport and, through the use of POOMA, for portable parallelism. Current capabilities of MC++ are discussed, along with physics and performance results on a variety of hardware, including all Accelerated Strategic Computing Initiative (ASCI) hardware. Current parallel performance indicates the ability to compute α-eigenvalues in seconds to minutes rather than hours to days. Future plans and the implementation of a general transport physics framework are also discussed

  20. Massive Parallelism of Monte-Carlo Simulation on Low-End Hardware using Graphic Processing Units

    International Nuclear Information System (INIS)

    Mburu, Joe Mwangi; Hah, Chang Joo Hah

    2014-01-01

    Within the past decade, research has been done on utilizing GPU massive parallelization in core simulation with impressive results but unfortunately, not much commercial application has been done in the nuclear field especially in reactor core simulation. The purpose of this paper is to give an introductory concept on the topic and illustrate the potential of exploiting the massive parallel nature of GPU computing on a simple monte-carlo simulation with very minimal hardware specifications. To do a comparative analysis, a simple two dimension monte-carlo simulation is implemented for both the CPU and GPU in order to evaluate performance gain based on the computing devices. The heterogeneous platform utilized in this analysis is done on a slow notebook with only 1GHz processor. The end results are quite surprising whereby high speedups obtained are almost a factor of 10. In this work, we have utilized heterogeneous computing in a GPU-based approach in applying potential high arithmetic intensive calculation. By applying a complex monte-carlo simulation on GPU platform, we have speed up the computational process by almost a factor of 10 based on one million neutrons. This shows how easy, cheap and efficient it is in using GPU in accelerating scientific computing and the results should encourage in exploring further this avenue especially in nuclear reactor physics simulation where deterministic and stochastic calculations are quite favourable in parallelization

  1. Massive Parallelism of Monte-Carlo Simulation on Low-End Hardware using Graphic Processing Units

    Energy Technology Data Exchange (ETDEWEB)

    Mburu, Joe Mwangi; Hah, Chang Joo Hah [KEPCO International Nuclear Graduate School, Ulsan (Korea, Republic of)

    2014-05-15

    Within the past decade, research has been done on utilizing GPU massive parallelization in core simulation with impressive results but unfortunately, not much commercial application has been done in the nuclear field especially in reactor core simulation. The purpose of this paper is to give an introductory concept on the topic and illustrate the potential of exploiting the massive parallel nature of GPU computing on a simple monte-carlo simulation with very minimal hardware specifications. To do a comparative analysis, a simple two dimension monte-carlo simulation is implemented for both the CPU and GPU in order to evaluate performance gain based on the computing devices. The heterogeneous platform utilized in this analysis is done on a slow notebook with only 1GHz processor. The end results are quite surprising whereby high speedups obtained are almost a factor of 10. In this work, we have utilized heterogeneous computing in a GPU-based approach in applying potential high arithmetic intensive calculation. By applying a complex monte-carlo simulation on GPU platform, we have speed up the computational process by almost a factor of 10 based on one million neutrons. This shows how easy, cheap and efficient it is in using GPU in accelerating scientific computing and the results should encourage in exploring further this avenue especially in nuclear reactor physics simulation where deterministic and stochastic calculations are quite favourable in parallelization.

  2. Ant colony algorithm implementation in electron and photon Monte Carlo transport: application to the commissioning of radiosurgery photon beams.

    Science.gov (United States)

    García-Pareja, S; Galán, P; Manzano, F; Brualla, L; Lallena, A M

    2010-07-01

    In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within approximately 3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  3. Ant colony algorithm implementation in electron and photon Monte Carlo transport: Application to the commissioning of radiosurgery photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Pareja, S.; Galan, P.; Manzano, F.; Brualla, L.; Lallena, A. M. [Servicio de Radiofisica Hospitalaria, Hospital Regional Universitario ' ' Carlos Haya' ' , Avda. Carlos Haya s/n, E-29010 Malaga (Spain); Unidad de Radiofisica Hospitalaria, Hospital Xanit Internacional, Avda. de los Argonautas s/n, E-29630 Benalmadena (Malaga) (Spain); NCTeam, Strahlenklinik, Universitaetsklinikum Essen, Hufelandstr. 55, D-45122 Essen (Germany); Departamento de Fisica Atomica, Molecular y Nuclear, Universidad de Granada, E-18071 Granada (Spain)

    2010-07-15

    Purpose: In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. Methods: The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. Results: The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within {approx}3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. Conclusions: The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  4. Ant colony algorithm implementation in electron and photon Monte Carlo transport: Application to the commissioning of radiosurgery photon beams

    International Nuclear Information System (INIS)

    Garcia-Pareja, S.; Galan, P.; Manzano, F.; Brualla, L.; Lallena, A. M.

    2010-01-01

    Purpose: In this work, the authors describe an approach which has been developed to drive the application of different variance-reduction techniques to the Monte Carlo simulation of photon and electron transport in clinical accelerators. Methods: The new approach considers the following techniques: Russian roulette, splitting, a modified version of the directional bremsstrahlung splitting, and the azimuthal particle redistribution. Their application is controlled by an ant colony algorithm based on an importance map. Results: The procedure has been applied to radiosurgery beams. Specifically, the authors have calculated depth-dose profiles, off-axis ratios, and output factors, quantities usually considered in the commissioning of these beams. The agreement between Monte Carlo results and the corresponding measurements is within ∼3%/0.3 mm for the central axis percentage depth dose and the dose profiles. The importance map generated in the calculation can be used to discuss simulation details in the different parts of the geometry in a simple way. The simulation CPU times are comparable to those needed within other approaches common in this field. Conclusions: The new approach is competitive with those previously used in this kind of problems (PSF generation or source models) and has some practical advantages that make it to be a good tool to simulate the radiation transport in problems where the quantities of interest are difficult to obtain because of low statistics.

  5. Monte Carlo photon transport on shared memory and distributed memory parallel processors

    International Nuclear Information System (INIS)

    Martin, W.R.; Wan, T.C.; Abdel-Rahman, T.S.; Mudge, T.N.; Miura, K.

    1987-01-01

    Parallelized Monte Carlo algorithms for analyzing photon transport in an inertially confined fusion (ICF) plasma are considered. Algorithms were developed for shared memory (vector and scalar) and distributed memory (scalar) parallel processors. The shared memory algorithm was implemented on the IBM 3090/400, and timing results are presented for dedicated runs with two, three, and four processors. Two alternative distributed memory algorithms (replication and dispatching) were implemented on a hypercube parallel processor (1 through 64 nodes). The replication algorithm yields essentially full efficiency for all cube sizes; with the 64-node configuration, the absolute performance is nearly the same as with the CRAY X-MP. The dispatching algorithm also yields efficiencies above 80% in a large simulation for the 64-processor configuration

  6. Radiosurgery of arteriovenous malformations

    International Nuclear Information System (INIS)

    Kawamoto, Shunsuke

    1994-01-01

    Steiner has first published a report of a case of cerebral arteriovenous malformation (AVM) treated with gamma knife radiosurgery in 1972. Since the mid-1980s, radiosurgery has increasingly received much attention. There have already been more than 6,000 radiosurgically treated AVM cases. This article reviews radiosurgery in the context of the following: (1) radiosurgery according to gamma knife, linear accelerator, heavy-charged particle Bragg-peak radiation and neutron; (2) therapeutic outcome in view of angiographically proven complete obliteration (CO) of AVM, including the time required for CO and factors regulating CO (such as the volume of AVM, radiation doses, correlation between the volume of AVM and radiation doses, age, and site of AVM), histopathological findings, and clinical complaints (such as headache and epilepsy) after radiosurgery; (3) bleeding after radiosurgery; (4) complications (including angiography-related complications, those immediately after radiosurgery, delayed complications, factors influencing delayed complications, and endocrine or growth retardation); (5) other problems (such as radiation doses, follow-up strategy, approaches to giant AVMs, and repeat irradiation); (6) indication of radiosurgery for lesions other than brain stem, and lesions of the mid-brain, pons and bulb. (N.K.) 134 refs

  7. Multilevel parallel strategy on Monte Carlo particle transport for the large-scale full-core pin-by-pin simulations

    International Nuclear Information System (INIS)

    Zhang, B.; Li, G.; Wang, W.; Shangguan, D.; Deng, L.

    2015-01-01

    This paper introduces the Strategy of multilevel hybrid parallelism of JCOGIN Infrastructure on Monte Carlo Particle Transport for the large-scale full-core pin-by-pin simulations. The particle parallelism, domain decomposition parallelism and MPI/OpenMP parallelism are designed and implemented. By the testing, JMCT presents the parallel scalability of JCOGIN, which reaches the parallel efficiency 80% on 120,000 cores for the pin-by-pin computation of the BEAVRS benchmark. (author)

  8. Implementation, capabilities, and benchmarking of Shift, a massively parallel Monte Carlo radiation transport code

    International Nuclear Information System (INIS)

    Pandya, Tara M.; Johnson, Seth R.; Evans, Thomas M.; Davidson, Gregory G.; Hamilton, Steven P.; Godfrey, Andrew T.

    2015-01-01

    This paper discusses the implementation, capabilities, and validation of Shift, a massively parallel Monte Carlo radiation transport package developed and maintained at Oak Ridge National Laboratory. It has been developed to scale well from laptop to small computing clusters to advanced supercomputers. Special features of Shift include hybrid capabilities for variance reduction such as CADIS and FW-CADIS, and advanced parallel decomposition and tally methods optimized for scalability on supercomputing architectures. Shift has been validated and verified against various reactor physics benchmarks and compares well to other state-of-the-art Monte Carlo radiation transport codes such as MCNP5, CE KENO-VI, and OpenMC. Some specific benchmarks used for verification and validation include the CASL VERA criticality test suite and several Westinghouse AP1000 ® problems. These benchmark and scaling studies show promising results

  9. SCALE Continuous-Energy Monte Carlo Depletion with Parallel KENO in TRITON

    International Nuclear Information System (INIS)

    Goluoglu, Sedat; Bekar, Kursat B.; Wiarda, Dorothea

    2012-01-01

    The TRITON sequence of the SCALE code system is a powerful and robust tool for performing multigroup (MG) reactor physics analysis using either the 2-D deterministic solver NEWT or the 3-D Monte Carlo transport code KENO. However, as with all MG codes, the accuracy of the results depends on the accuracy of the MG cross sections that are generated and/or used. While SCALE resonance self-shielding modules provide rigorous resonance self-shielding, they are based on 1-D models and therefore 2-D or 3-D effects such as heterogeneity of the lattice structures may render final MG cross sections inaccurate. Another potential drawback to MG Monte Carlo depletion is the need to perform resonance self-shielding calculations at each depletion step for each fuel segment that is being depleted. The CPU time and memory required for self-shielding calculations can often eclipse the resources needed for the Monte Carlo transport. This summary presents the results of the new continuous-energy (CE) calculation mode in TRITON. With the new capability, accurate reactor physics analyses can be performed for all types of systems using the SCALE Monte Carlo code KENO as the CE transport solver. In addition, transport calculations can be performed in parallel mode on multiple processors.

  10. Parallel Atomistic Simulations

    Energy Technology Data Exchange (ETDEWEB)

    HEFFELFINGER,GRANT S.

    2000-01-18

    Algorithms developed to enable the use of atomistic molecular simulation methods with parallel computers are reviewed. Methods appropriate for bonded as well as non-bonded (and charged) interactions are included. While strategies for obtaining parallel molecular simulations have been developed for the full variety of atomistic simulation methods, molecular dynamics and Monte Carlo have received the most attention. Three main types of parallel molecular dynamics simulations have been developed, the replicated data decomposition, the spatial decomposition, and the force decomposition. For Monte Carlo simulations, parallel algorithms have been developed which can be divided into two categories, those which require a modified Markov chain and those which do not. Parallel algorithms developed for other simulation methods such as Gibbs ensemble Monte Carlo, grand canonical molecular dynamics, and Monte Carlo methods for protein structure determination are also reviewed and issues such as how to measure parallel efficiency, especially in the case of parallel Monte Carlo algorithms with modified Markov chains are discussed.

  11. A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

    Science.gov (United States)

    Dewaraja, Yuni K; Ljungberg, Michael; Majumdar, Amitava; Bose, Abhijit; Koral, Kenneth F

    2002-02-01

    This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For (131)I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction.

  12. Binocular optical axis parallelism detection precision analysis based on Monte Carlo method

    Science.gov (United States)

    Ying, Jiaju; Liu, Bingqi

    2018-02-01

    According to the working principle of the binocular photoelectric instrument optical axis parallelism digital calibration instrument, and in view of all components of the instrument, the various factors affect the system precision is analyzed, and then precision analysis model is established. Based on the error distribution, Monte Carlo method is used to analyze the relationship between the comprehensive error and the change of the center coordinate of the circle target image. The method can further guide the error distribution, optimize control the factors which have greater influence on the comprehensive error, and improve the measurement accuracy of the optical axis parallelism digital calibration instrument.

  13. Generation of Random Numbers and Parallel Random Number Streams for Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    L. Yu. Barash

    2012-01-01

    Full Text Available Modern methods and libraries for high quality pseudorandom number generation and for generation of parallel random number streams for Monte Carlo simulations are considered. The probability equidistribution property and the parameters when the property holds at dimensions up to logarithm of mesh size are considered for Multiple Recursive Generators.

  14. A Pipelined and Parallel Architecture for Quantum Monte Carlo Simulations on FPGAs

    Directory of Open Access Journals (Sweden)

    Akila Gothandaraman

    2010-01-01

    Full Text Available Recent advances in Field-Programmable Gate Array (FPGA technology make reconfigurable computing using FPGAs an attractive platform for accelerating scientific applications. We develop a deeply pipelined and parallel architecture for Quantum Monte Carlo simulations using FPGAs. Quantum Monte Carlo simulations enable us to obtain the structural and energetic properties of atomic clusters. We experiment with different pipeline structures for each component of the design and develop a deeply pipelined architecture that provides the best performance in terms of achievable clock rate, while at the same time has a modest use of the FPGA resources. We discuss the details of the pipelined and generic architecture that is used to obtain the potential energy and wave function of a cluster of atoms.

  15. Synchronous parallel kinetic Monte Carlo for continuum diffusion-reaction systems

    International Nuclear Information System (INIS)

    Martinez, E.; Marian, J.; Kalos, M.H.; Perlado, J.M.

    2008-01-01

    A novel parallel kinetic Monte Carlo (kMC) algorithm formulated on the basis of perfect time synchronicity is presented. The algorithm is intended as a generalization of the standard n-fold kMC method, and is trivially implemented in parallel architectures. In its present form, the algorithm is not rigorous in the sense that boundary conflicts are ignored. We demonstrate, however, that, in their absence, or if they were correctly accounted for, our algorithm solves the same master equation as the serial method. We test the validity and parallel performance of the method by solving several pure diffusion problems (i.e. with no particle interactions) with known analytical solution. We also study diffusion-reaction systems with known asymptotic behavior and find that, for large systems with interaction radii smaller than the typical diffusion length, boundary conflicts are negligible and do not affect the global kinetic evolution, which is seen to agree with the expected analytical behavior. Our method is a controlled approximation in the sense that the error incurred by ignoring boundary conflicts can be quantified intrinsically, during the course of a simulation, and decreased arbitrarily (controlled) by modifying a few problem-dependent simulation parameters

  16. penORNL: a parallel Monte Carlo photon and electron transport package using PENELOPE

    International Nuclear Information System (INIS)

    Bekar, Kursat B.; Miller, Thomas Martin; Patton, Bruce W.; Weber, Charles F.

    2015-01-01

    The parallel Monte Carlo photon and electron transport code package penORNL was developed at Oak Ridge National Laboratory to enable advanced scanning electron microscope (SEM) simulations on high-performance computing systems. This paper discusses the implementations, capabilities and parallel performance of the new code package. penORNL uses PENELOPE for its physics calculations and provides all available PENELOPE features to the users, as well as some new features including source definitions specifically developed for SEM simulations, a pulse-height tally capability for detailed simulations of gamma and x-ray detectors, and a modified interaction forcing mechanism to enable accurate energy deposition calculations. The parallel performance of penORNL was extensively tested with several model problems, and very good linear parallel scaling was observed with up to 512 processors. penORNL, along with its new features, will be available for SEM simulations upon completion of the new pulse-height tally implementation.

  17. Dynamic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Luan Shuang; Swanson, Nathan; Chen Zhe; Ma Lijun

    2009-01-01

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and

  18. {sup 10}B-augmented fast neutron radiosurgery for brain tumor treatment

    Energy Technology Data Exchange (ETDEWEB)

    Wang, C.; Chen, J. [Georgia Institute of Technology, Atlanta, GA (United States); Halpern, D.; Moore, C. [Isotron Inc., Alpharetta, GA (United States)

    2000-10-01

    We have investigated a new {sup 10}B-enhanced fast neutron treatment modality based on a concept similar to the x-ray radiosurgery or gamma knife. The results from our proof-of-principle Monte Carlo calculations clearly indicate that the dose-volume-histogram (DVH) of a 5-cm-deep tumor treated with multiple converging neutron beams is superior to that treated with a single broad neutron beam. To find out if the idea of neutron radiosurgery is practical, we have designed a small neutron beam based on 1-mA of 7-MeV deuterons bombarding a thick beryllium target, i.e. via Be(d,n) reactions. Such a deuteron beam is already achievable based on the existing accelerator technology, and it is also inexpensive. The Monte Carlo results show that the Be(d,n)-based facility produces an average dose rate of 1.9 Gy min{sup -1} in the tumor volume. For a typical tumor dose of 20 Gy, the treatment time would be 10.5 minutes. The results also show that the preferential loading of 100 ppm of {sup 10}B will produce in average an additional 8% of dose to tumor cells via {sup 10}B(n,{alpha}){sup 7}Li reactions. (author)

  19. Parallelization of MCNP 4, a Monte Carlo neutron and photon transport code system, in highly parallel distributed memory type computer

    International Nuclear Information System (INIS)

    Masukawa, Fumihiro; Takano, Makoto; Naito, Yoshitaka; Yamazaki, Takao; Fujisaki, Masahide; Suzuki, Koichiro; Okuda, Motoi.

    1993-11-01

    In order to improve the accuracy and calculating speed of shielding analyses, MCNP 4, a Monte Carlo neutron and photon transport code system, has been parallelized and measured of its efficiency in the highly parallel distributed memory type computer, AP1000. The code has been analyzed statically and dynamically, then the suitable algorithm for parallelization has been determined for the shielding analysis functions of MCNP 4. This includes a strategy where a new history is assigned to the idling processor element dynamically during the execution. Furthermore, to avoid the congestion of communicative processing, the batch concept, processing multi-histories by a unit, has been introduced. By analyzing a sample cask problem with 2,000,000 histories by the AP1000 with 512 processor elements, the 82 % of parallelization efficiency is achieved, and the calculational speed has been estimated to be around 50 times as fast as that of FACOM M-780. (author)

  20. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Souhami, L.; Podgorsak, E.B.

    1990-01-01

    Radiosurgery is an irradiation technique which over the last few years became frequently utilized. Because of the sophisticated and expensive equipments originally required, its use was restricted initially to a few and specialized centers in the world. The introduction of new techniques based on isocentric linear accelerators made now this therapy available to the major radiotherapy centers. Some of the essential requirements for radiosurgery include an accurate determination of the target volume, 3-dimensional dose calculation, accurate dose delivery to the target volume and a sharp dose fall-off outside the target volume. In this paper, we discuss the principles, the indications, some of the techniques, and the initial therapeutics results with radiosurgery. (author) [pt

  1. Monte Carlo simulations of quantum systems on massively parallel supercomputers

    International Nuclear Information System (INIS)

    Ding, H.Q.

    1993-01-01

    A large class of quantum physics applications uses operator representations that are discrete integers by nature. This class includes magnetic properties of solids, interacting bosons modeling superfluids and Cooper pairs in superconductors, and Hubbard models for strongly correlated electrons systems. This kind of application typically uses integer data representations and the resulting algorithms are dominated entirely by integer operations. The authors implemented an efficient algorithm for one such application on the Intel Touchstone Delta and iPSC/860. The algorithm uses a multispin coding technique which allows significant data compactification and efficient vectorization of Monte Carlo updates. The algorithm regularly switches between two data decompositions, corresponding naturally to different Monte Carlo updating processes and observable measurements such that only nearest-neighbor communications are needed within a given decomposition. On 128 nodes of Intel Delta, this algorithm updates 183 million spins per second (compared to 21 million on CM-2 and 6.2 million on a Cray Y-MP). A systematic performance analysis shows a better than 90% efficiency in the parallel implementation

  2. Load balancing in highly parallel processing of Monte Carlo code for particle transport

    International Nuclear Information System (INIS)

    Higuchi, Kenji; Takemiya, Hiroshi; Kawasaki, Takuji

    1998-01-01

    In parallel processing of Monte Carlo (MC) codes for neutron, photon and electron transport problems, particle histories are assigned to processors making use of independency of the calculation for each particle. Although we can easily parallelize main part of a MC code by this method, it is necessary and practically difficult to optimize the code concerning load balancing in order to attain high speedup ratio in highly parallel processing. In fact, the speedup ratio in the case of 128 processors remains in nearly one hundred times when using the test bed for the performance evaluation. Through the parallel processing of the MCNP code, which is widely used in the nuclear field, it is shown that it is difficult to attain high performance by static load balancing in especially neutron transport problems, and a load balancing method, which dynamically changes the number of assigned particles minimizing the sum of the computational and communication costs, overcomes the difficulty, resulting in nearly fifteen percentage of reduction for execution time. (author)

  3. Dynamic gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Luan Shuang; Swanson, Nathan; Chen Zhe [Department of Computer Science, University of New Mexico, Albuquerque, NM 87131 (United States); Ma Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA 94143 (United States)], E-mail: sluan@cs.unm.edu, E-mail: nate@cs.unm.edu, E-mail: zchen@cs.unm.edu, E-mail: lijunma@radonc.ucsf.edu

    2009-03-21

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can

  4. Brain tumor radiosurgery. Current status and strategies to enhance the effect of radiosurgery

    International Nuclear Information System (INIS)

    Niranjan, A.; Lunsford, L.D.; Gobbel, G.T.; Kondziolka, D.; Maitz, A.; Flickinger, J.C.

    2000-01-01

    First, the current status of brain tumor radiosurgery is reviewed, and radiosurgery for brain tumors, including benign tumors, malignant tumors, primary glial tumors, and metastatic tumors, is described. Rapid developments in neuroimaging, stereotactic techniques, and robotic technology in the last decade have contributed to improved results and wider applications of radiosurgery. Radiosurgery has become the preferred management modality for many intracranial tumors, including schwannomas, meningiomas, and metastatic tumors. Although radiosurgery provides survival benefits in patients with diffuse malignant brain tumors, cure is still not possible. Microscopic tumor infiltration into surrounding normal tissue is the main cause of recurrence. Additional strategies are needed to specifically target tumor cells. Next, strategies to enhance the effect of radiosurgery are reviewed. Whereas the long-term clinical results of radiosurgery have established its role in the treatment of benign tumors, additional strategies are needed to improve cell killing in malignant brain tumors and to protect normal surrounding brain. The first strategy included the use of various agents to protect normal brain while delivering a high dose to the tumor cells, but finding an effective radioprotective agent has been problematic. Pentobarbital and 21-aminosteroid (21-AS) are presented as examples. The second strategy for radiation protection aimed at the repair of radiation-induced damage to the normal brain. The cause of radiation-induced breakdown of normal tissue is unclear. The white matter and the cerebral vasculature appear to be particularly susceptible to radiation. Oligodendrocytes and endothelial cells may be critical targets of radiation. The authors hypothesize that radiation-induced damage to these cell types can be repaired by neural stem cells. They also describe the use of tumor necrosis factor alpha (TNF-alpha) and neural stem cells as a means of enhancing the effect of

  5. Qualitative Simulation of Photon Transport in Free Space Based on Monte Carlo Method and Its Parallel Implementation

    Directory of Open Access Journals (Sweden)

    Xueli Chen

    2010-01-01

    Full Text Available During the past decade, Monte Carlo method has obtained wide applications in optical imaging to simulate photon transport process inside tissues. However, this method has not been effectively extended to the simulation of free-space photon transport at present. In this paper, a uniform framework for noncontact optical imaging is proposed based on Monte Carlo method, which consists of the simulation of photon transport both in tissues and in free space. Specifically, the simplification theory of lens system is utilized to model the camera lens equipped in the optical imaging system, and Monte Carlo method is employed to describe the energy transformation from the tissue surface to the CCD camera. Also, the focusing effect of camera lens is considered to establish the relationship of corresponding points between tissue surface and CCD camera. Furthermore, a parallel version of the framework is realized, making the simulation much more convenient and effective. The feasibility of the uniform framework and the effectiveness of the parallel version are demonstrated with a cylindrical phantom based on real experimental results.

  6. The current status of radiosurgery

    International Nuclear Information System (INIS)

    Mehta, Minesh P.

    1996-01-01

    Objectives: Review the role of radiosurgery in recurrent malignant gliomas for palliative purposes. Review the role of radiosurgery in newly diagnosed malignant glioma as boost therapy and emphasize the randomized clinical trials underway. Review the role of radiosurgery in the management of patients with brain metastases and emphasize the major prognostic factors. Review the recently initiated clinical trials for brain metastases using radiosurgery. Review the role of radiosurgery in the management of benign tumors with specific emphasis on meningioma and acoustic neuroma. Emphasize the rationale for fractionation and present the preliminary results of fractionated stereotactic radiation. Stereotactic localization techniques, originally designed for neurosurgery, have been used to delivery high single doses of radiation to small intracranial targets for more than 25 years, a technique referred to as stereotactic radiosurgery. Radiosurgery has proven to be an attractive alternative to surgery in the management of several benign tumors, such as vestibular schwannomas with better preservation of hearing and facial nerve function than microsurgical resection. For other benign tumors such as meningioma and pituitary adenoma, preliminary results are promising, but longer range studies to confirm high tumor control rates are necessary. For patients with malignant glioma, radiosurgery has been used to escalate the radiation dose to enhance tumor control following surgery and radiation therapy. The rationale for this is grounded in the recent confirmatory randomized prospective trial verifying the value of brachytherapy in this disease. The results of radiosurgery from single institutional experiences for primary and recurrent malignant glioma indicate a palliative benefit as well as a potential survival benefit in a select sub-group of patients based on the appropriate mix of prognostic criteria such as patient age, performance status, tumor size and extent of resection

  7. A microcosting study of microsurgery, LINAC radiosurgery, and gamma knife radiosurgery in meningioma patients

    Science.gov (United States)

    van Putten, Erik; Nijdam, Wideke M.; Hanssens, Patrick; Beute, Guus N.; Nowak, Peter J.; Dirven, Clemens M.; Hakkaart-van Roijen, Leona

    2010-01-01

    The aim of the present study is to determine and compare initial treatment costs of microsurgery, linear accelerator (LINAC) radiosurgery, and gamma knife radiosurgery in meningioma patients. Additionally, the follow-up costs in the first year after initial treatment were assessed. Cost analyses were performed at two neurosurgical departments in The Netherlands from the healthcare providers’ perspective. A total of 59 patients were included, of whom 18 underwent microsurgery, 15 underwent LINAC radiosurgery, and 26 underwent gamma knife radiosurgery. A standardized microcosting methodology was employed to ensure that the identified cost differences would reflect only actual cost differences. Initial treatment costs, using equipment costs per fraction, were €12,288 for microsurgery, €1,547 for LINAC radiosurgery, and €2,412 for gamma knife radiosurgery. Higher initial treatment costs for microsurgery were predominantly due to inpatient stay (€5,321) and indirect costs (€4,350). LINAC and gamma knife radiosurgery were equally expensive when equipment was valued per treatment (€2,198 and €2,412, respectively). Follow-up costs were slightly, but not significantly, higher for microsurgery compared with LINAC and gamma knife radiosurgery. Even though initial treatment costs were over five times higher for microsurgery compared with both radiosurgical treatments, our study gives indications that the relative cost difference may decrease when follow-up costs occurring during the first year after initial treatment are incorporated. This reinforces the need to consider follow-up costs after initial treatment when examining the relative costs of alternative treatments. PMID:20526795

  8. Radiosurgery for brain arteriovenous malformations

    International Nuclear Information System (INIS)

    Latorzeff, I.; Schlienger, M.; Sabatier, J.; Borius, P.Y.; Lotterie, J.A.; Bourdin, S.; Menegalli, D.; Cognard, C.; Januel, A.C.; Desal, H.; Debono, B.; Blond, S.

    2012-01-01

    Radiosurgery as treatment for arteriovenous malformations has shown a good efficacy in reducing intracranial bleeding due to rupture. The choice of therapeutic modalities is based on evolutive risk and arteriovenous malformations volume, patient profile and risks stratification following therapeutic techniques (microsurgery, radiosurgery, embolization). Nidus size, arteriovenous malformations anatomical localization, prior embolization or bleeding, distributed dose are predictive factors for radio-surgery's good results and tolerance. This review article will highlight arteriovenous malformations radiosurgery indications and discuss recent irradiation alternatives for large arteriovenous malformation volumes. (authors)

  9. Stereotactic radiosurgery for hemangioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yoshimasa; Kobayashi, Tatsuya; Yamada, Yasushi; Kida, Yoshihisa; Iwakoshi, Takayasu; Yoshimoto, Masayuki [Komaki City Hospital, Aichi (Japan). Gamma Knife Center

    2001-12-01

    We evaluated the treatment results of Gamma Knife radiosurgery for intracranial hemanigioblastoma of von Hippel-Lindau syndrome or sporadic disease. Stereotactic radiosurgery was performed in 20 patients with 35 hemangioblastomas over a 9-year interval. The mean age of the patients was 48.5 years (range, 18-79 years). The volume of the tumors varied from 0.03 to 19 ml (mean, 3.0 ml), and the mean tumor margin dose was 17.8 Gy (range, 14-24 Gy). Clinical and neuroimaging follow-up was obtained 6 to 58 months (mean 26.2 months) after radiosurgery. Thirty-one (89%) of 35 tumors were controlled locally. Two tumors (6%) disappeared and 11 (31%) decreased in size during follow-up period. Eighteen (52%) remained unchanged in size. Three out of four enlarged tumors were resected surgically after radiosurgery. Another tumor was resected surgically to improve the patient's symptoms of nausea and vomiting caused by persistent perifocal edema in spite of reduced tumor volume. Only one patient, who had a tumor in the 4th ventricle arising from the brainstem, died 12 months after radiosurgery. Although the treated tumor remained stable in size, he developed aspiration pneumonia due to brainstem dysfunction caused by perifocal edema. All tumors less than 1 cm in diameter did not progress during follow-up period. For small hemangioblastomas, radiosurgery is a safe and effective option to control disease. If a large tumor is treated by radiosurgery, careful observation of the patient's neurological condition is necessary. (author)

  10. Scalable and massively parallel Monte Carlo photon transport simulations for heterogeneous computing platforms.

    Science.gov (United States)

    Yu, Leiming; Nina-Paravecino, Fanny; Kaeli, David; Fang, Qianqian

    2018-01-01

    We present a highly scalable Monte Carlo (MC) three-dimensional photon transport simulation platform designed for heterogeneous computing systems. Through the development of a massively parallel MC algorithm using the Open Computing Language framework, this research extends our existing graphics processing unit (GPU)-accelerated MC technique to a highly scalable vendor-independent heterogeneous computing environment, achieving significantly improved performance and software portability. A number of parallel computing techniques are investigated to achieve portable performance over a wide range of computing hardware. Furthermore, multiple thread-level and device-level load-balancing strategies are developed to obtain efficient simulations using multiple central processing units and GPUs. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  11. MC++: A parallel, portable, Monte Carlo neutron transport code in C++

    International Nuclear Information System (INIS)

    Lee, S.R.; Cummings, J.C.; Nolen, S.D.

    1997-01-01

    MC++ is an implicit multi-group Monte Carlo neutron transport code written in C++ and based on the Parallel Object-Oriented Methods and Applications (POOMA) class library. MC++ runs in parallel on and is portable to a wide variety of platforms, including MPPs, SMPs, and clusters of UNIX workstations. MC++ is being developed to provide transport capabilities to the Accelerated Strategic Computing Initiative (ASCI). It is also intended to form the basis of the first transport physics framework (TPF), which is a C++ class library containing appropriate abstractions, objects, and methods for the particle transport problem. The transport problem is briefly described, as well as the current status and algorithms in MC++ for solving the transport equation. The alpha version of the POOMA class library is also discussed, along with the implementation of the transport solution algorithms using POOMA. Finally, a simple test problem is defined and performance and physics results from this problem are discussed on a variety of platforms

  12. Dosimetric calculations by Monte Carlo for treatments of radiosurgery with the Leksell Gamma Knife, homogeneous and non homogeneous cases; Calculos dosimetricos por Monte Carlo para tratamientos de radiocirugia con el Leksell Gamma Knife, casos homogeneo y no homogeneo

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Lallena R, A.M. [Universidad de Granada (Spain)

    2004-07-01

    In this work dose profiles are calculated that are obtained modeling treatments of radiosurgery with the Leksell Gamma Knife. This was made with the simulation code Monte Carlo Penelope for an homogeneous mannequin and one not homogeneous. Its were carried out calculations with the irradiation focus coinciding with the center of the mannequin as in near areas to the bone interface. Each one of the calculations one carries out for the 4 skull treatment that it includes the Gamma Knife and using a model simplified of their 201 sources of {sup 60} Co. It was found that the dose profiles differ of the order of 2% when the isocenter coincides with the center of the mannequin and they ascend to near 5% when the isocenter moves toward the skull. (Author)

  13. Radiosurgery for pituitary adenomas

    International Nuclear Information System (INIS)

    Castro, Douglas Guedes de; Salvajoli, Joao Victor; Canteras, Miguel Montes; Cecilio, Soraya A. Jorge

    2006-01-01

    Pituitary adenomas represent nearly 15% of all intracranial tumors. Multimodal treatment includes microsurgery, medical management and radiotherapy. Microsurgery is the primary recommendation for nonfunctioning and most of functioning adenomas, except for prolactinomas that are usually managed with dopamine agonist drugs. However, about 30% of patients require additional treatment after microsurgery for recurrent or residual tumors. In these cases, fractionated radiation therapy has been the traditional treatment. More recently, radiosurgery has been established as a treatment option. Radiosurgery allows the delivery of prescribed dose with high precision strictly to the target and spares the surrounding tissues. Therefore, the risks of hypopituitarism, visual damage and vasculopathy are significantly lower. Furthermore, the latency of the radiation response after radiosurgery is substantially shorter than that of fractionated radiotherapy. The goal of this review is to define the efficacy, safety and role of radiosurgery for treatment of pituitary adenomas and to present the preliminary results of our institution. (author)

  14. SU-E-T-446: Evaluation of the Dosimetric Properties of a Diode Detector to Proton Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Teran, A [Loma Linda University Medical Center, Loma Linda, CA (United States); San Diego State University, San Diego, CA (United States); McAuley, G; Slater, J M [Loma Linda University, Loma Linda, CA (United States); Slater, J D; Wroe, A [Loma Linda University Medical Center, Loma Linda, CA (United States)

    2014-06-01

    Purpose: To test the PTW PR60020 proton dosimetry diode in radiation fields relevant to proton radiosurgery applications and evaluate its suitability as a high resolution, real time dosimetry device. Methods: Data was collected using our standard nominal radiosurgery energies of 126 MeV and 155 MeV through a single stage scattering system, corresponding to a range of 9.7 and 15 cm in water respectively. Various beam modulations were tested as part of this study. Depth dose and beam profile measurements were completed with the PTW PR60020 dosimetry diode with comparative measurements using a PTW Markus ionization chamber and EBT2 Gafchromic film. Monte Carlo simulations were also completed for comparison. Results: The single 1 mm{sup 2} by 20 μm thick sensitive volume allowed for high spatial resolution measurements while maintaining sufficient sensitive volume to ensure that measurements could be completed without excessive beam delivery. Depth dose profiles exhibited negligible LET dependence which typically impacts film and other solid state dosimetry devices, while beam ranges measured with the PTW diode were within 1 mm of ion chamber data. In an edge on arrangement beam profiles were also measured within 0.5 mm full-width at half-maximum at various depths as compared to film and simulation data. Conclusion: The PTW PR60020 proved to be a very useful radiation metrology apparatus for proton radiosurgery applications. Its waterproof and rugged construction allowed for easy deployment in phantoms or water tanks that are commonly used in proton radiosurgery QA. Dosimetrically, the diode exhibited negligible LET dependence as a function of depth, while in edge on arrangement to the incident proton beam it facilitated the measurement of beam profiles with a spatial resolution comparable to both Monte Carlo and film measurements. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

  15. Parallel Monte Carlo Particle Transport and the Quality of Random Number Generators: How Good is Good Enough?

    International Nuclear Information System (INIS)

    Procassini, R J; Beck, B R

    2004-01-01

    It might be assumed that use of a ''high-quality'' random number generator (RNG), producing a sequence of ''pseudo random'' numbers with a ''long'' repetition period, is crucial for producing unbiased results in Monte Carlo particle transport simulations. While several theoretical and empirical tests have been devised to check the quality (randomness and period) of an RNG, for many applications it is not clear what level of RNG quality is required to produce unbiased results. This paper explores the issue of RNG quality in the context of parallel, Monte Carlo transport simulations in order to determine how ''good'' is ''good enough''. This study employs the MERCURY Monte Carlo code, which incorporates the CNPRNG library for the generation of pseudo-random numbers via linear congruential generator (LCG) algorithms. The paper outlines the usage of random numbers during parallel MERCURY simulations, and then describes the source and criticality transport simulations which comprise the empirical basis of this study. A series of calculations for each test problem in which the quality of the RNG (period of the LCG) is varied provides the empirical basis for determining the minimum repetition period which may be employed without producing a bias in the mean integrated results

  16. A PARALLEL MONTE CARLO CODE FOR SIMULATING COLLISIONAL N-BODY SYSTEMS

    International Nuclear Information System (INIS)

    Pattabiraman, Bharath; Umbreit, Stefan; Liao, Wei-keng; Choudhary, Alok; Kalogera, Vassiliki; Memik, Gokhan; Rasio, Frederic A.

    2013-01-01

    We present a new parallel code for computing the dynamical evolution of collisional N-body systems with up to N ∼ 10 7 particles. Our code is based on the Hénon Monte Carlo method for solving the Fokker-Planck equation, and makes assumptions of spherical symmetry and dynamical equilibrium. The principal algorithmic developments involve optimizing data structures and the introduction of a parallel random number generation scheme as well as a parallel sorting algorithm required to find nearest neighbors for interactions and to compute the gravitational potential. The new algorithms we introduce along with our choice of decomposition scheme minimize communication costs and ensure optimal distribution of data and workload among the processing units. Our implementation uses the Message Passing Interface library for communication, which makes it portable to many different supercomputing architectures. We validate the code by calculating the evolution of clusters with initial Plummer distribution functions up to core collapse with the number of stars, N, spanning three orders of magnitude from 10 5 to 10 7 . We find that our results are in good agreement with self-similar core-collapse solutions, and the core-collapse times generally agree with expectations from the literature. Also, we observe good total energy conservation, within ∼ 5 , 128 for N = 10 6 and 256 for N = 10 7 . The runtime reaches saturation with the addition of processors beyond these limits, which is a characteristic of the parallel sorting algorithm. The resulting maximum speedups we achieve are approximately 60×, 100×, and 220×, respectively.

  17. Radiosurgery for Large Brain Metastases

    International Nuclear Information System (INIS)

    Han, Jung Ho; Kim, Dong Gyu; Chung, Hyun-Tai; Paek, Sun Ha; Park, Chul-Kee; Jung, Hee-Won

    2012-01-01

    Purpose: To determine the efficacy and safety of radiosurgery in patients with large brain metastases treated with radiosurgery. Patients and Methods: Eighty patients with large brain metastases (>14 cm 3 ) were treated with radiosurgery between 1998 and 2009. The mean age was 59 ± 11 years, and 49 (61.3%) were men. Neurologic symptoms were identified in 77 patients (96.3%), and 30 (37.5%) exhibited a dependent functional status. The primary disease was under control in 36 patients (45.0%), and 44 (55.0%) had a single lesion. The mean tumor volume was 22.4 ± 8.8 cm 3 , and the mean marginal dose prescribed was 13.8 ± 2.2 Gy. Results: The median survival time from radiosurgery was 7.9 months (95% confidence interval [CI], 5.343–10.46), and the 1-year survival rate was 39.2%. Functional improvement within 1–4 months or the maintenance of the initial independent status was observed in 48 (60.0%) and 20 (25.0%) patients after radiosurgery, respectively. Control of the primary disease, a marginal dose of ≥11 Gy, and a tumor volume ≥26 cm 3 were significantly associated with overall survival (hazard ratio, 0.479; p = .018; 95% CI, 0.261–0.880; hazard ratio, 0.350; p = .004; 95% CI, 0.171–0.718; hazard ratio, 2.307; p = .006; 95% CI, 1.274–4.180, respectively). Unacceptable radiation-related toxicities (Radiation Toxicity Oncology Group central nervous system toxicity Grade 3, 4, and 5 in 7, 6, and 2 patients, respectively) developed in 15 patients (18.8%). Conclusion: Radiosurgery seems to have a comparable efficacy with surgery for large brain metastases. However, the rate of radiation-related toxicities after radiosurgery should be considered when deciding on a treatment modality.

  18. Radiosurgery by Leksell gamma knife

    International Nuclear Information System (INIS)

    Novotny, Josef

    2008-01-01

    The learning objectives of the lecture were as follows: to learn basic principles of Leksell gamma knife (LGK) radiosurgery; to discuss imaging, treatment planning and optimization procedures; to discuss quality assurance for LGK treatments; and to present examples of diagnoses treated by LGK. The following topics were discussed: Radiosurgery - definition, components of selectivity, fundamentals; Leksell gamma knife - principles; Stereotactic target localization; Radiosurgery - imaging; Treatment planning; LGK treatment; Quality control - process tree, LGK, distortion of scanners, 3D phantom measurements; Physical and technical parameters; and Clinical applications. (P.A.)

  19. Gamma knife radiosurgery in children

    NARCIS (Netherlands)

    Baumann, G. S.; Wara, W. M.; Larson, D. A.; Sneed, P. K.; Gutin, P. H.; Ciricillo, S. F.; McDermott, M. W.; Park, E.; Stalpers, L. J.; Verhey, L. J.; Smith, V.; Petti, P. L.; Edwards, M. S.

    1996-01-01

    52 pediatric patients were treated with radiosurgery at the University of California, San Francisco. Arteriovenous malformations were treated in 27 patients. Complete obliteration was noted in 4 of 12 patients imaged more than 2 years after radiosurgery. Arteriovenous malformation rebleed was noted

  20. A PARALLEL MONTE CARLO CODE FOR SIMULATING COLLISIONAL N-BODY SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Pattabiraman, Bharath; Umbreit, Stefan; Liao, Wei-keng; Choudhary, Alok; Kalogera, Vassiliki; Memik, Gokhan; Rasio, Frederic A., E-mail: bharath@u.northwestern.edu [Center for Interdisciplinary Exploration and Research in Astrophysics, Northwestern University, Evanston, IL (United States)

    2013-02-15

    We present a new parallel code for computing the dynamical evolution of collisional N-body systems with up to N {approx} 10{sup 7} particles. Our code is based on the Henon Monte Carlo method for solving the Fokker-Planck equation, and makes assumptions of spherical symmetry and dynamical equilibrium. The principal algorithmic developments involve optimizing data structures and the introduction of a parallel random number generation scheme as well as a parallel sorting algorithm required to find nearest neighbors for interactions and to compute the gravitational potential. The new algorithms we introduce along with our choice of decomposition scheme minimize communication costs and ensure optimal distribution of data and workload among the processing units. Our implementation uses the Message Passing Interface library for communication, which makes it portable to many different supercomputing architectures. We validate the code by calculating the evolution of clusters with initial Plummer distribution functions up to core collapse with the number of stars, N, spanning three orders of magnitude from 10{sup 5} to 10{sup 7}. We find that our results are in good agreement with self-similar core-collapse solutions, and the core-collapse times generally agree with expectations from the literature. Also, we observe good total energy conservation, within {approx}< 0.04% throughout all simulations. We analyze the performance of the code, and demonstrate near-linear scaling of the runtime with the number of processors up to 64 processors for N = 10{sup 5}, 128 for N = 10{sup 6} and 256 for N = 10{sup 7}. The runtime reaches saturation with the addition of processors beyond these limits, which is a characteristic of the parallel sorting algorithm. The resulting maximum speedups we achieve are approximately 60 Multiplication-Sign , 100 Multiplication-Sign , and 220 Multiplication-Sign , respectively.

  1. Parallelization and implementation of approximate root isolation for nonlinear system by Monte Carlo

    Science.gov (United States)

    Khosravi, Ebrahim

    1998-12-01

    This dissertation solves a fundamental problem of isolating the real roots of nonlinear systems of equations by Monte-Carlo that were published by Bush Jones. This algorithm requires only function values and can be applied readily to complicated systems of transcendental functions. The implementation of this sequential algorithm provides scientists with the means to utilize function analysis in mathematics or other fields of science. The algorithm, however, is so computationally intensive that the system is limited to a very small set of variables, and this will make it unfeasible for large systems of equations. Also a computational technique was needed for investigating a metrology of preventing the algorithm structure from converging to the same root along different paths of computation. The research provides techniques for improving the efficiency and correctness of the algorithm. The sequential algorithm for this technique was corrected and a parallel algorithm is presented. This parallel method has been formally analyzed and is compared with other known methods of root isolation. The effectiveness, efficiency, enhanced overall performance of the parallel processing of the program in comparison to sequential processing is discussed. The message passing model was used for this parallel processing, and it is presented and implemented on Intel/860 MIMD architecture. The parallel processing proposed in this research has been implemented in an ongoing high energy physics experiment: this algorithm has been used to track neutrinoes in a super K detector. This experiment is located in Japan, and data can be processed on-line or off-line locally or remotely.

  2. Overcoming artificial spatial correlations in simulations of superstructure domain growth with parallel Monte Carlo algorithms

    International Nuclear Information System (INIS)

    Schleier, W.; Besold, G.; Heinz, K.

    1992-01-01

    The authors study the applicability of parallelized/vectorized Monte Carlo (MC) algorithms to the simulation of domain growth in two-dimensional lattice gas models undergoing an ordering process after a rapid quench below an order-disorder transition temperature. As examples they consider models with 2 x 1 and c(2 x 2) equilibrium superstructures on the square and rectangular lattices, respectively. They also study the case of phase separation ('1 x 1' islands) on the square lattice. A generalized parallel checkerboard algorithm for Kawasaki dynamics is shown to give rise to artificial spatial correlations in all three models. However, only if superstructure domains evolve do these correlations modify the kinetics by influencing the nucleation process and result in a reduced growth exponent compared to the value from the conventional heat bath algorithm with random single-site updates. In order to overcome these artificial modifications, two MC algorithms with a reduced degree of parallelism ('hybrid' and 'mask' algorithms, respectively) are presented and applied. As the results indicate, these algorithms are suitable for the simulation of superstructure domain growth on parallel/vector computers. 60 refs., 10 figs., 1 tab

  3. Intracranial osteosarcoma after radiosurgery. Case report

    International Nuclear Information System (INIS)

    Sanno, Naoko; Hayashi, Shinkichi; Shimura, Toshiro; Maeda, Shotaro; Teramoto, Akira

    2004-01-01

    A 56-year-old woman presented with an intracranial osteosarcoma at the site of previous radiosurgery, manifesting as sudden onset of headache and left hemiparesis with aphasia. She had a previous history of stereotactic radiosurgery for an intracranial tumor under a diagnosis of falx meningioma. Computed tomography showed intratumoral and peritumoral hemorrhage at the right parietofrontal region. Gross total resection of the tumor with hematoma was performed. The histological diagnosis was osteosarcoma. Sarcomatous change is a rare complication of radiotherapy. This case illustrates that osteosarcoma may develop years after radiosurgery for benign brain neoplasm. (author)

  4. Patients burden in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kralik, G.; Fribertova, M.; Trosanova, D.; Kolarcikova, E.

    2009-01-01

    Radiosurgery is one time application of High radiation to a stereotactically defined volume. Treatment delivery involves multiple stereotactically targeted, arced fields. The goal of Radiosurgery is to deliver a high dose to target, while only a minimum dose is delivered to adjacent normal tissue that are just a few millimeters away . Stereotactic Radiosurgery on linac has been employed at St. Elisabeth Cancer Institute in Bratislava since 1993. Until July 31,2008, 1 030 subjects have been treated including patients with brain tumors, metastases, recurrent tumours, and A V malformations, using Leibinger stereotaxy collimators or Mimic MLC system on a Linac accelerator. The presentation shows dose delivery to risk organs in different indications. (authors)

  5. Parallel Algorithms for Monte Carlo Particle Transport Simulation on Exascale Computing Architectures

    Science.gov (United States)

    Romano, Paul Kollath

    Monte Carlo particle transport methods are being considered as a viable option for high-fidelity simulation of nuclear reactors. While Monte Carlo methods offer several potential advantages over deterministic methods, there are a number of algorithmic shortcomings that would prevent their immediate adoption for full-core analyses. In this thesis, algorithms are proposed both to ameliorate the degradation in parallel efficiency typically observed for large numbers of processors and to offer a means of decomposing large tally data that will be needed for reactor analysis. A nearest-neighbor fission bank algorithm was proposed and subsequently implemented in the OpenMC Monte Carlo code. A theoretical analysis of the communication pattern shows that the expected cost is O( N ) whereas traditional fission bank algorithms are O(N) at best. The algorithm was tested on two supercomputers, the Intrepid Blue Gene/P and the Titan Cray XK7, and demonstrated nearly linear parallel scaling up to 163,840 processor cores on a full-core benchmark problem. An algorithm for reducing network communication arising from tally reduction was analyzed and implemented in OpenMC. The proposed algorithm groups only particle histories on a single processor into batches for tally purposes---in doing so it prevents all network communication for tallies until the very end of the simulation. The algorithm was tested, again on a full-core benchmark, and shown to reduce network communication substantially. A model was developed to predict the impact of load imbalances on the performance of domain decomposed simulations. The analysis demonstrated that load imbalances in domain decomposed simulations arise from two distinct phenomena: non-uniform particle densities and non-uniform spatial leakage. The dominant performance penalty for domain decomposition was shown to come from these physical effects rather than insufficient network bandwidth or high latency. The model predictions were verified with

  6. Kilovoltage radiosurgery with gold nanoparticles for neovascular age-related macular degeneration (AMD): a Monte Carlo evaluation

    Science.gov (United States)

    Brivio, D.; Zygmanski, P.; Arnoldussen, M.; Hanlon, J.; Chell, E.; Sajo, E.; Makrigiorgos, G. M.; Ngwa, W.

    2015-12-01

    This work uses Monte Carlo radiation transport simulation to assess the potential benefits of gold nanoparticles (AuNP) in the treatment of neovascular age-related macular degeneration with stereotactic radiosurgery. Clinically, a 100 kVp x-ray beam of 4 mm diameter is aimed at the macula to deliver an ablative dose in a single fraction. In the transport model, AuNP accumulated at the bottom of the macula are targeted with a source representative of the clinical beam in order to provide enhanced dose to the diseased macular endothelial cells. It is observed that, because of the AuNP, the dose to the endothelial cells can be significantly enhanced, allowing for greater sparing of optic nerve, retina and other neighboring healthy tissue. For 20 nm diameter AuNP concentration of 32 mg g-1, which has been shown to be achievable in vivo, a dose enhancement ratio (DER) of 1.97 was found to be possible, which could potentially be increased through appropriate optimization of beam quality and/or AuNP targeting. A significant enhancement in dose is seen in the vicinity of the AuNP layer within 30 μm, peaked at the AuNP-tissue interface. Different angular tilting of the 4 mm beam results in a similar enhancement. The DER inside and in the penumbra of the 4 mm irradiation-field are almost the same while the actual delivered dose is more than one order of magnitude lower outside the field leading to normal tissue sparing. The prescribed dose to macular endothelial cells can be delivered using almost half of the radiation allowing reduction of dose to the neighboring organs such as retina/optic nerve by 49% when compared to a treatment without AuNP.

  7. Kilovoltage radiosurgery with gold nanoparticles for neovascular age-related macular degeneration (AMD): a Monte Carlo evaluation

    International Nuclear Information System (INIS)

    Brivio, D; Zygmanski, P; Makrigiorgos, G M; Ngwa, W; Arnoldussen, M; Hanlon, J; Chell, E; Sajo, E

    2015-01-01

    This work uses Monte Carlo radiation transport simulation to assess the potential benefits of gold nanoparticles (AuNP) in the treatment of neovascular age-related macular degeneration with stereotactic radiosurgery. Clinically, a 100 kVp x-ray beam of 4 mm diameter is aimed at the macula to deliver an ablative dose in a single fraction. In the transport model, AuNP accumulated at the bottom of the macula are targeted with a source representative of the clinical beam in order to provide enhanced dose to the diseased macular endothelial cells. It is observed that, because of the AuNP, the dose to the endothelial cells can be significantly enhanced, allowing for greater sparing of optic nerve, retina and other neighboring healthy tissue. For 20 nm diameter AuNP concentration of 32 mg g −1 , which has been shown to be achievable in vivo, a dose enhancement ratio (DER) of 1.97 was found to be possible, which could potentially be increased through appropriate optimization of beam quality and/or AuNP targeting. A significant enhancement in dose is seen in the vicinity of the AuNP layer within 30 μm, peaked at the AuNP-tissue interface. Different angular tilting of the 4 mm beam results in a similar enhancement. The DER inside and in the penumbra of the 4 mm irradiation-field are almost the same while the actual delivered dose is more than one order of magnitude lower outside the field leading to normal tissue sparing. The prescribed dose to macular endothelial cells can be delivered using almost half of the radiation allowing reduction of dose to the neighboring organs such as retina/optic nerve by 49% when compared to a treatment without AuNP. (paper)

  8. Trilogy Image-Guided Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Huntzinger, Calvin; Friedman, William; Bova, Frank; Fox, Timothy; Bouchet, Lionel; Boeh, Lester M.B.A.

    2007-01-01

    Full integration of advanced imaging, noninvasive immobilization, positioning, and motion-management methods into radiosurgery have resulted in fundamental changes in therapeutic strategies and approaches that are leading us to the treatment room of the future. With the introduction of image-guided radiosurgery (IGRS) systems, such as Trilogy TM , physicians have for the first time a practical means of routinely identifying and treating very small lesions throughout the body. Using new imaging processes such as positron emission tomography/computed tomography (PET/CT) scans, clinics may be able to detect these lesions and then eradicate them with image-guided stereotactic radiosurgery treatments. Thus, there is promise that cancer could be turned into a chronic disease, managed through a series of checkups, and Trilogy treatments when metastatic lesions reappear

  9. Vectorization and parallelization of Monte-Carlo programs for calculation of radiation transport

    International Nuclear Information System (INIS)

    Seidel, R.

    1995-01-01

    The versatile MCNP-3B Monte-Carlo code written in FORTRAN77, for simulation of the radiation transport of neutral particles, has been subjected to vectorization and parallelization of essential parts, without touching its versatility. Vectorization is not dependent on a specific computer. Several sample tasks have been selected in order to test the vectorized MCNP-3B code in comparison to the scalar MNCP-3B code. The samples are a representative example of the 3-D calculations to be performed for simulation of radiation transport in neutron and reactor physics. (1) 4πneutron detector. (2) High-energy calorimeter. (3) PROTEUS benchmark (conversion rates and neutron multiplication factors for the HCLWR (High Conversion Light Water Reactor)). (orig./HP) [de

  10. Stereotactic radiosurgery: the preferred management for patients with nonvestibular schwannomas?

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Foote, Robert L.; Stafford, Scott L.

    2002-01-01

    Purpose: To review patient outcomes after radiosurgery of nonvestibular schwannomas. Methods and Materials: From April 1992 to February 2000, 23 patients had radiosurgery at our center for nonvestibular schwannomas. Affected cranial nerves included the trochlear (n=1), trigeminal (n=10), jugular foramen region (n=10), and hypoglossal (n=2). Nine patients had undergone one or more prior tumor resections. One patient had a malignant schwannoma; 2 patients had neurofibromatosis. The median prescription isodose volume was 8.9 cc (range, 0.2 to 17.6 cc). The median tumor margin dose was 18 Gy (range, 12 to 20 Gy); the median maximum dose was 36 Gy (range, 24 to 40 Gy). The median follow-up after radiosurgery was 43 months (range, 12 to 111 months). Results: Twenty-two of 23 tumors (96%) were either smaller (n=12) or unchanged in size (n=10) after radiosurgery. One patient with a malignant schwannoma had tumor progression outside the irradiated volume despite having both radiosurgery and fractionated radiation therapy (50.4 Gy); he died 4 years later. Morbidity related to radiosurgery occurred in 4 patients (17%). Three of 10 patients with trigeminal schwannomas suffered new or worsened trigeminal dysfunction after radiosurgery. One patient with a hypoglossal schwannoma had eustachian tube dysfunction after radiosurgery. No patient with a lower cranial nerve schwannoma developed any hearing loss, facial weakness, or swallowing difficulty after radiosurgery. Conclusions: Although the reported number of patients having radiosurgery for nonvestibular schwannomas is limited, the high tumor control rates demonstrated after vestibular schwannoma radiosurgery should apply to these rare tumors. Compared to historical controls treated with surgical resection, radiosurgery appears to have less treatment-associated morbidity for nonvestibular schwannomas, especially for schwannomas involving the lower cranial nerves

  11. Gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yohsimasa; Kida, Yoshihisa

    2003-01-01

    Gamma knife radiosurgery has become a new treatment modality in the field of neurosurgery since the first gamma knife was brought into Japan in 1990. Advances in applications of new indications and long-term results have been continued to evolve during the past 12 years. Based on the experience of more than 4,500 cases treated by gamma knife at Komaki City Hospital, long-term results of arteriovenous malformations (AVMs), metastatic brain tumors, acoustic neurinomas, meningiomas and trigeminal neuralgias are presented. Radiosurgery has become a novel treatment modality, especially for AVM, acoustic neurinoma and meningioma, which were once only treatable by conventional surgery, and shows a high cure rate in AVM cases and high control rate in benign tumors without major complications. The effects of radiosurgery for metastatic brain tumors have been thought to be superior to fractionated radiotherapy due to high response and control rates, and patients showed improved quality of life although no prolongation of the life span was obtained. Gamma knife treatment for trigeminal neuralgia has been shown to be effective and less invasive than microvascular decompression, and is useful for cases resistant to conventional therapies and as an initial treatment as well. (author)

  12. Radiosurgery scope of practice in Canada: A report of the Canadian association of radiation oncology (CARO) radiosurgery advisory committee

    International Nuclear Information System (INIS)

    Roberge, David; Menard, Cynthia; Bauman, Glenn; Chan, Alex; Mulroy, Liam; Sahgal, Arjun; Malone, Shawn; McKenzie, Michael; Schroeder, Garry; Fortin, Marie-Andree; Ebacher, Annie; Milosevic, Michael

    2010-01-01

    Radiosurgery has a long history in Canada. Since the treatment of the first patient at the McGill University Health Center in 1985, radiosurgery programs have been developed from coast to coast. These have included multidisciplinary teams of radiation oncologists, neurosurgeons, medical physicists, radiation technologists and other health professionals. In 2008, the CARO Board of Directors requested that a working group be formed to define the role of the radiation oncologist in the practice of radiosurgery. Taking into account evolving technology, changing clinical practice and current scope of practice literature, the working group made recommendations as to the role of the radiation oncologists. These recommendations were endorsed by the Canadian Association of Radiation Oncology board of directors in September 2009 and are present herein. It is recognized that patients benefit from a team approach to their care but it is recommended that qualified radiation oncologists be involved in radiosurgery delivery from patient consultation to follow-up. In addition, radiation oncologists should continue to be involved in the administrative aspects of radiosurgery programs, from equipment selection to ongoing quality assurance/quality improvement.

  13. A geometrically based method for automated radiosurgery planning

    International Nuclear Information System (INIS)

    Wagner, Thomas H.; Yi Taeil; Meeks, Sanford L.; Bova, Francis J.; Brechner, Beverly L.; Chen Yunmei; Buatti, John M.; Friedman, William A.; Foote, Kelly D.; Bouchet, Lionel G.

    2000-01-01

    Purpose: A geometrically based method of multiple isocenter linear accelerator radiosurgery treatment planning optimization was developed, based on a target's solid shape. Methods and Materials: Our method uses an edge detection process to determine the optimal sphere packing arrangement with which to cover the planning target. The sphere packing arrangement is converted into a radiosurgery treatment plan by substituting the isocenter locations and collimator sizes for the spheres. Results: This method is demonstrated on a set of 5 irregularly shaped phantom targets, as well as a set of 10 clinical example cases ranging from simple to very complex in planning difficulty. Using a prototype implementation of the method and standard dosimetric radiosurgery treatment planning tools, feasible treatment plans were developed for each target. The treatment plans generated for the phantom targets showed excellent dose conformity and acceptable dose homogeneity within the target volume. The algorithm was able to generate a radiosurgery plan conforming to the Radiation Therapy Oncology Group (RTOG) guidelines on radiosurgery for every clinical and phantom target examined. Conclusions: This automated planning method can serve as a valuable tool to assist treatment planners in rapidly and consistently designing conformal multiple isocenter radiosurgery treatment plans.

  14. A package of Linux scripts for the parallelization of Monte Carlo simulations

    Science.gov (United States)

    Badal, Andreu; Sempau, Josep

    2006-09-01

    Despite the fact that fast computers are nowadays available at low cost, there are many situations where obtaining a reasonably low statistical uncertainty in a Monte Carlo (MC) simulation involves a prohibitively large amount of time. This limitation can be overcome by having recourse to parallel computing. Most tools designed to facilitate this approach require modification of the source code and the installation of additional software, which may be inconvenient for some users. We present a set of tools, named clonEasy, that implement a parallelization scheme of a MC simulation that is free from these drawbacks. In clonEasy, which is designed to run under Linux, a set of "clone" CPUs is governed by a "master" computer by taking advantage of the capabilities of the Secure Shell (ssh) protocol. Any Linux computer on the Internet that can be ssh-accessed by the user can be used as a clone. A key ingredient for the parallel calculation to be reliable is the availability of an independent string of random numbers for each CPU. Many generators—such as RANLUX, RANECU or the Mersenne Twister—can readily produce these strings by initializing them appropriately and, hence, they are suitable to be used with clonEasy. This work was primarily motivated by the need to find a straightforward way to parallelize PENELOPE, a code for MC simulation of radiation transport that (in its current 2005 version) employs the generator RANECU, which uses a combination of two multiplicative linear congruential generators (MLCGs). Thus, this paper is focused on this class of generators and, in particular, we briefly present an extension of RANECU that increases its period up to ˜5×10 and we introduce seedsMLCG, a tool that provides the information necessary to initialize disjoint sequences of an MLCG to feed different CPUs. This program, in combination with clonEasy, allows to run PENELOPE in parallel easily, without requiring specific libraries or significant alterations of the

  15. Gamma Knife Radiosurgery for Acromegaly

    Directory of Open Access Journals (Sweden)

    John D. Rolston

    2012-01-01

    Full Text Available Acromegaly is debilitating disease occasionally refractory to surgical and medical treatment. Stereotactic radiosurgery, and in particular Gamma Knife surgery (GKS, has proven to be an effective noninvasive adjunct to traditional treatments, leading to disease remission in a substantial proportion of patients. Such remission holds the promise of eliminating the need for expensive medications, along with side effects, as well as sparing patients the damaging sequelae of uncontrolled acromegaly. Numerous studies of radiosurgical treatments for acromegaly have been carried out. These illustrate an overall remission rate over 40%. Morbidity from radiosurgery is infrequent but can include cranial nerve palsies and hypopituitarism. Overall, stereotactic radiosurgery is a promising therapy for patients with acromegaly and deserves further study to refine its role in the treatment of affected patients.

  16. A derivation and scalable implementation of the synchronous parallel kinetic Monte Carlo method for simulating long-time dynamics

    Science.gov (United States)

    Byun, Hye Suk; El-Naggar, Mohamed Y.; Kalia, Rajiv K.; Nakano, Aiichiro; Vashishta, Priya

    2017-10-01

    Kinetic Monte Carlo (KMC) simulations are used to study long-time dynamics of a wide variety of systems. Unfortunately, the conventional KMC algorithm is not scalable to larger systems, since its time scale is inversely proportional to the simulated system size. A promising approach to resolving this issue is the synchronous parallel KMC (SPKMC) algorithm, which makes the time scale size-independent. This paper introduces a formal derivation of the SPKMC algorithm based on local transition-state and time-dependent Hartree approximations, as well as its scalable parallel implementation based on a dual linked-list cell method. The resulting algorithm has achieved a weak-scaling parallel efficiency of 0.935 on 1024 Intel Xeon processors for simulating biological electron transfer dynamics in a 4.2 billion-heme system, as well as decent strong-scaling parallel efficiency. The parallel code has been used to simulate a lattice of cytochrome complexes on a bacterial-membrane nanowire, and it is broadly applicable to other problems such as computational synthesis of new materials.

  17. Technical Note: Dose gradients and prescription isodose in orthovoltage stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Fagerstrom, Jessica M.; Bender, Edward T.; Culberson, Wesley S.

    2016-01-01

    Purpose: The purpose of this work is to examine the trade-off between prescription isodose and dose gradients in orthovoltage stereotactic radiosurgery. Methods: Point energy deposition kernels (EDKs) describing photon and electron transport were calculated using Monte Carlo methods. EDKs were generated from 10  to 250 keV, in 10 keV increments. The EDKs were converted to pencil beam kernels and used to calculate dose profiles through isocenter from a 4π isotropic delivery from all angles of circularly collimated beams. Monoenergetic beams and an orthovoltage polyenergetic spectrum were analyzed. The dose gradient index (DGI) is the ratio of the 50% prescription isodose volume to the 100% prescription isodose volume and represents a metric by which dose gradients in stereotactic radiosurgery (SRS) may be evaluated. Results: Using the 4π dose profiles calculated using pencil beam kernels, the relationship between DGI and prescription isodose was examined for circular cones ranging from 4 to 18 mm in diameter and monoenergetic photon beams with energies ranging from 20 to 250 keV. Values were found to exist for prescription isodose that optimize DGI. Conclusions: The relationship between DGI and prescription isodose was found to be dependent on both field size and energy. Examining this trade-off is an important consideration for designing optimal SRS systems.

  18. Assessment of MicroDiamond PTW 60019 detector and its comparison with other detectors for relative dosimetry in small radiosurgery fields of the Leksell gamma knife perfexion

    International Nuclear Information System (INIS)

    Novotny, J. Jr.; Kozubikova, P.; Pastykova, V.; Pipek, J.; Bhatnagar, J. P.; Huq, M. S.; Veselsky, T.

    2014-01-01

    Measurement of relative output factors (ROF) for the Leksell Gamma Knife (LGK) is not a trivial task due to strict demands of an accurate set up and small size of measured radiosurgery fields. The purpose of this study was to perform an assessment of a new synthetic single crystal MicroDiamond PTW 60019 detector (volume 0.004 mm 3 ) for measurement of ROFs for 4 mm and 8 mm collimators for the LGK Perfexion. Small sensitive volume of this detector, near water equivalence and low energy dependence make it an attractive candidate for small field dosimetry. Results obtained in this study were compared with results measured by broad variety of different detectors and also Monte Carlo (MC) simulation. MicroDiamond detector connected to PTW UNIDOS electrometer was positioned in ELEKTA spherical phantom and pre-irradiated to dose of 5 Gy. Measurements were performed in two different detector positions: 1) parallel with table axis, 2) orthogonal to table axis. Electrometer timer of 1 min was used to measure subsequently signal from 16 mm, 8 mm and 4 mm beams. Altogether ten measurements were performed for each of three collimator sizes. Results from MicroDiamond were compared with those obtained from various types of detectors used in the past by authors for measurement of LGK ROFs. New synthetic single crystal MicroDiamond PTW 60019 detector appears to be a very promising detector for relative output factor measurements in very small radiosurgery fields. (authors)

  19. Stereotactic radiosurgery for spinal metastases: a literature review

    International Nuclear Information System (INIS)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala

    2013-01-01

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy – melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  20. Treat high cervical spinal arteriovenous malformation with Cyberknife radiosurgery

    Directory of Open Access Journals (Sweden)

    Yu-Fen Huang

    2014-01-01

    Full Text Available This paper describes the use of CyberKnife radiosurgery in the treatment of accidentally found cervical spinal arteriovenous malformation (AVM. We present the case of a patient with cervical spinal AVM, who developed progressive neck pain, gait disturbance, urine and stool incontinence 2 weeks after the fell down accident. The patient underwent CyberKnife radiosurgery. After CyberKnife radiosurgery for 2 years, the patient′s neck pain diminished and was able to keep the walk without any assistance. The management of cervical spinal AVM varies. This patient demonstrated a successful treatment of cervical spinal AVM with CyberKnife radiosurgery.

  1. Value of stereotactic radiosurgery in patients with multiple brain metastases

    International Nuclear Information System (INIS)

    Chen Jie; Lin Zhiguo; Li Qingguo; Shen Hong

    2002-01-01

    Objective: To analyze the prognostic factors and evaluate the effect of stereotactic radiosurgery for patients with multiple brain metastases. Methods: Comparison was made in 53 such patients treated by stereotactic radiosurgery plus radiotherapy and 53 treated by radiotherapy alone. Patients were matched-paired according to the following criteria: age, Karnofsky performance scale (KPS) before treatment, extent of systemic cancer and number of brain metastasis. Forty patients had stereotactic radiosurgery, 13 patients stereotactic fractionated radiosurgery. In the stereotactic radiosurgery group, the patients were given a mean marginal dose of 20 Gy. Methods of stereotactic fractionated radiosurgery was 4-12 Gy per fraction , twice a week to a total dose of 15-30 Gy. Whole brain radiotherapy was given immediately after stereotactic radiosurgery. For patients treated by radiotherapy alone, the entire brain was treated by 30-40 Gy in 3-4 weeks. Results: The median survival was 11.6 months in stereotactic radiosurgery plus radiotherapy and 6.7 months in radiotherapy alone. The one year survival rate and one year local control rate were 44.3%, 17.1% and 50.9%, 13. 2%. Those with KPS increased after treatment gave 1-year survivals of 69.8% and 30.2%, respectively. The validity rates in CT or MRI three months after treatment were 82.0% and 55.0%. The difference in the two groups was found to be statistically significant (P < 0.01). 23.3% of death in the stereotactic radiosurgery plus radiotherapy group was due to brain metastasis vs 51.0% in the radiotherapy alone group (P < 0.05). Complication of the two groups was similar. Conclusion: Stereotactic radiosurgery plus radiotherapy is superior to radiotherapy alone for multiple brain metastases in improving the local control and ultimate outcome

  2. Embolization with Gamma Knife Radiosurgery of Giant Intracranial Arteriovenous Malformations.

    Science.gov (United States)

    Chun, Dong Hyun; Kim, Moo Seong; Kim, Sung Tae; Paeng, Sung Hwa; Jeong, Hae Woong; Lee, Won Hee

    2016-01-01

    Giant arteriovenous malformations (i.e., those greater than 6 cm maximum diameter or volume > 33 cc) are difficult to treat and often carry higher treatment morbidity and mortality rates. In our study, we reviewed the angiographic results and clinical outcomes for 11 patients with giant arteriovenous malformations who were treated between 1994 and 2012. The patients selected included 9 males (82%) and 2 females (18%). Their presenting symptoms were hemorrhage (n=2; 18%), seizure (n=7; 64%), and headache (n=2; 12%). Nine patients were Spetzler-Martin Grade III, 2 were Spetzler-Martin Grade IV. The mean arteriovenous malformation volume was 41 cc (33-52 cc). The mean age of the patients was 45.1 years (24-57 years) and the mean radiation dose delivered to the margin of the nidus was 14.2 Gy. Ten patients received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery, 1 patient received pre-Gamma Knife radiosurgery embolization and Gamma Knife radiosurgery twice and the interval between Gamma Knife radiosurgeries was 3 months. The complete obliteration rate following Gamma Knife radiosurgery was 36%, subtotal obliteration ( > 70% decreased size of nidus) was 36%, and partial obliteration was 28%. One patient experienced a small hemorrhage after embolization. Combined embolization and Gamma Knife radiosurgery showed successful obliteration of the arteriovenous malformation nidus. The use of embolization to initially reduce nidus size followed by Gamma Knife radiosurgery improves the treatment results. Repeated Gamma Knife radiosurgery should be a treatment option when there is a small nidus remnant.

  3. Stereotactic radiosurgery using the gamma knife

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, Shunsuke; Sasaki, Tomio; Matsutani, Masao; Takakura, Kintomo; Terahara, Atsuro (Tokyo Univ. (Japan). Faculty of Medicine)

    1992-03-01

    Since stereotactic radiosurgery using a gamma knife was developed in 1968 by Leksell, it has been used with increasing frequency in Japan. During the period from June 19, 1990 through December 20, 1991, 218 patients have been treated with stereotactic radiosurgery using a gamma knife. Of them, 116 had vascular lesions (116), including arteriovenous malformation (114), dural arteriovenous malformation (one), and cerebral aneurysm (one); and the other 102 had tumorous lesions, including acoustic neurinoma (48), meningioma (26), pituitary tumor (11), metastatic tumor (7), germ cell tumor (3), glioma (2), hemangioblastoma (2), chordoma (one), craniopharyngioma (one), and trigeminal neurinoma (one). In this article, candidates of stereotactic radiosurgery using a gamma knife are discussed, with particular attention to clinical results of the aforementioned 218 patients. (N.K.) 54 refs.

  4. Stereotactic Radiosurgery for Classical Trigeminal Neuralgia

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-04-01

    Full Text Available Trigeminal neuralgia is a debilitating pain syndrome with a distinct symptom mainly excruciating facial pain that tends to come and go unpredictably in sudden shock-like attacks. Medical management remains the primary treatment for classical trigeminal neuralgia. When medical therapy failed, surgery with microvascular decompression can be performed. Radiosurgery can be offered for classical trigeminal neuralgia patients who are not surgical candidate or surgery refusal and they should not in acute pain condition. Radiosurgery is widely used because of good therapeutic result and low complication rate. Weakness of this technique is a latency period, which is time required for pain relief. It usually ranges from 1 to 2 months. This review enlightens the important role of radiosurgery in the treatment of classical trigeminal neuralgia.

  5. Robotic Radiosurgery. Treating prostata cancer and related genitourinary applications

    International Nuclear Information System (INIS)

    Ponsky, Lee E.

    2012-01-01

    Prostate cancer is the most common cancer among North American and European men, but its treatment continues to be problematic owing to serious side-effects, including erectile dysfunction, urinary incontinence, and potential lower GI complications. Robotic radiosurgery offers a novel, rapid, non-invasive outpatient treatment option for prostate cancer that combines robotics, advanced image-guided motion detection, and automated real-time corrective spatial positioning with submillimeter precision. This book examines all aspects of the treatment of prostate cancer with robotic radiosurgery. After introductory sections on radiosurgery as a multidisciplinary practice and specific issues relating to prostate cancer, the important challenge posed by prostate motion when administering radiation therapy is examined in depth, with detailed discussion as to how image-guided robotic radiosurgery overcomes this problem by continously identifying the precise location of the prostate throughout the course of treatment. A further major section is devoted to a discussion of techniques and potential radiobiological and clinical advantages of hypofractionated radiation delivery by means of robotic radiosurgery systems. The book closes by discussing other emerging genitourinary applications of robotic radiosurgery. All of the authors are experts in their field who present a persuasive case for this fascinating technique. (orig.)

  6. Robotic Radiosurgery. Treating prostata cancer and related genitourinary applications

    Energy Technology Data Exchange (ETDEWEB)

    Ponsky, Lee E. (ed.) [Case Western Reserve University School of Medicine, Cleveland, OH (United States). University Hospitals Case Medical Center

    2012-07-01

    Prostate cancer is the most common cancer among North American and European men, but its treatment continues to be problematic owing to serious side-effects, including erectile dysfunction, urinary incontinence, and potential lower GI complications. Robotic radiosurgery offers a novel, rapid, non-invasive outpatient treatment option for prostate cancer that combines robotics, advanced image-guided motion detection, and automated real-time corrective spatial positioning with submillimeter precision. This book examines all aspects of the treatment of prostate cancer with robotic radiosurgery. After introductory sections on radiosurgery as a multidisciplinary practice and specific issues relating to prostate cancer, the important challenge posed by prostate motion when administering radiation therapy is examined in depth, with detailed discussion as to how image-guided robotic radiosurgery overcomes this problem by continously identifying the precise location of the prostate throughout the course of treatment. A further major section is devoted to a discussion of techniques and potential radiobiological and clinical advantages of hypofractionated radiation delivery by means of robotic radiosurgery systems. The book closes by discussing other emerging genitourinary applications of robotic radiosurgery. All of the authors are experts in their field who present a persuasive case for this fascinating technique. (orig.)

  7. Vectorization, parallelization and porting of nuclear codes (vectorization and parallelization). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Ishizuki, Shigeru; Kawai, Wataru; Nemoto, Toshiyuki; Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki; Kawasaki, Nobuo; Yatake, Yo-ichi

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the vectorization and parallelization on vector processors. In this vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics NTV (n-particle, Temperature and Velocity) Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated Propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model / multi-group model) MVP/GMVP on the Paragon are described. In the porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. (author)

  8. Implementation of the DPM Monte Carlo code on a parallel architecture for treatment planning applications.

    Science.gov (United States)

    Tyagi, Neelam; Bose, Abhijit; Chetty, Indrin J

    2004-09-01

    We have parallelized the Dose Planning Method (DPM), a Monte Carlo code optimized for radiotherapy class problems, on distributed-memory processor architectures using the Message Passing Interface (MPI). Parallelization has been investigated on a variety of parallel computing architectures at the University of Michigan-Center for Advanced Computing, with respect to efficiency and speedup as a function of the number of processors. We have integrated the parallel pseudo random number generator from the Scalable Parallel Pseudo-Random Number Generator (SPRNG) library to run with the parallel DPM. The Intel cluster consisting of 800 MHz Intel Pentium III processor shows an almost linear speedup up to 32 processors for simulating 1 x 10(8) or more particles. The speedup results are nearly linear on an Athlon cluster (up to 24 processors based on availability) which consists of 1.8 GHz+ Advanced Micro Devices (AMD) Athlon processors on increasing the problem size up to 8 x 10(8) histories. For a smaller number of histories (1 x 10(8)) the reduction of efficiency with the Athlon cluster (down to 83.9% with 24 processors) occurs because the processing time required to simulate 1 x 10(8) histories is less than the time associated with interprocessor communication. A similar trend was seen with the Opteron Cluster (consisting of 1400 MHz, 64-bit AMD Opteron processors) on increasing the problem size. Because of the 64-bit architecture Opteron processors are capable of storing and processing instructions at a faster rate and hence are faster as compared to the 32-bit Athlon processors. We have validated our implementation with an in-phantom dose calculation study using a parallel pencil monoenergetic electron beam of 20 MeV energy. The phantom consists of layers of water, lung, bone, aluminum, and titanium. The agreement in the central axis depth dose curves and profiles at different depths shows that the serial and parallel codes are equivalent in accuracy.

  9. Implementation of the DPM Monte Carlo code on a parallel architecture for treatment planning applications

    International Nuclear Information System (INIS)

    Tyagi, Neelam; Bose, Abhijit; Chetty, Indrin J.

    2004-01-01

    We have parallelized the Dose Planning Method (DPM), a Monte Carlo code optimized for radiotherapy class problems, on distributed-memory processor architectures using the Message Passing Interface (MPI). Parallelization has been investigated on a variety of parallel computing architectures at the University of Michigan-Center for Advanced Computing, with respect to efficiency and speedup as a function of the number of processors. We have integrated the parallel pseudo random number generator from the Scalable Parallel Pseudo-Random Number Generator (SPRNG) library to run with the parallel DPM. The Intel cluster consisting of 800 MHz Intel Pentium III processor shows an almost linear speedup up to 32 processors for simulating 1x10 8 or more particles. The speedup results are nearly linear on an Athlon cluster (up to 24 processors based on availability) which consists of 1.8 GHz+ Advanced Micro Devices (AMD) Athlon processors on increasing the problem size up to 8x10 8 histories. For a smaller number of histories (1x10 8 ) the reduction of efficiency with the Athlon cluster (down to 83.9% with 24 processors) occurs because the processing time required to simulate 1x10 8 histories is less than the time associated with interprocessor communication. A similar trend was seen with the Opteron Cluster (consisting of 1400 MHz, 64-bit AMD Opteron processors) on increasing the problem size. Because of the 64-bit architecture Opteron processors are capable of storing and processing instructions at a faster rate and hence are faster as compared to the 32-bit Athlon processors. We have validated our implementation with an in-phantom dose calculation study using a parallel pencil monoenergetic electron beam of 20 MeV energy. The phantom consists of layers of water, lung, bone, aluminum, and titanium. The agreement in the central axis depth dose curves and profiles at different depths shows that the serial and parallel codes are equivalent in accuracy

  10. MCBooster: a library for fast Monte Carlo generation of phase-space decays on massively parallel platforms.

    Science.gov (United States)

    Alves Júnior, A. A.; Sokoloff, M. D.

    2017-10-01

    MCBooster is a header-only, C++11-compliant library that provides routines to generate and perform calculations on large samples of phase space Monte Carlo events. To achieve superior performance, MCBooster is capable to perform most of its calculations in parallel using CUDA- and OpenMP-enabled devices. MCBooster is built on top of the Thrust library and runs on Linux systems. This contribution summarizes the main features of MCBooster. A basic description of the user interface and some examples of applications are provided, along with measurements of performance in a variety of environments

  11. Treatment planning optimization for linear accelerator radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.

    1998-01-01

    Purpose: Linear accelerator radiosurgery uses multiple arcs delivered through circular collimators to produce a nominally spherical dose distribution. Production of dose distributions that conform to irregular lesions or conformally avoid critical neural structures requires a detailed understanding of the available treatment planning parameters. Methods and Materials: Treatment planning parameters that may be manipulated within a single isocenter to provide conformal avoidance and dose conformation to ellipsoidal lesions include differential arc weighting and gantry start/stop angles. More irregular lesions require the use of multiple isocenters. Iterative manipulation of treatment planning variables can be difficult and computationally expensive, especially if the effects of these manipulations are not well defined. Effects of treatment parameter manipulation are explained and illustrated. This is followed by description of the University of Florida Stereotactic Radiosurgery Treatment Planning Algorithm. This algorithm organizes the manipulations into a practical approach for radiosurgery treatment planning. Results: Iterative treatment planning parameters may be efficiently manipulated to achieve optimal treatment plans by following the University of Florida Treatment Planning Algorithm. The ability to produce conformal stereotactic treatment plans using the algorithm is demonstrated for a variety of clinical presentations. Conclusion: The standard dose distribution produced in linear accelerator radiosurgery is spherical, but manipulation of available treatment planning parameters may result in optimal dose conformation. The University of Florida Treatment Planning Algorithm organizes available treatment parameters to efficiently produce conformal radiosurgery treatment plans

  12. Combined embolization and gamma knife radiosurgery for cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Guo, W.Y.; Wikholm, G.; Karlsson, B.; Lindquist, C.; Svendsen, P.; Ericson, K.

    1993-01-01

    In a study of 46 patients with cerebral arteriovenous malformations (AVMs) the value of combining embolization and gamma knife radiosurgery was assessed. In 35 patients with large grade III to V AVMs (Spetzler-Martin system) staged combined treatment was planned. In 11 patients, radiosurgery complemented embolization for a residual AVM. The number of embolization sessions ranged from 1 to 7 (median 2). Twenty-six patients needed multiple embolization sessions. In 28 patients the grade of AVMs decreased as a result of embolization. In 16 patients collateral feeding vessels developed after embolization which made delineation of the residual nidus difficult. The time lag between the last embolization and radiosurgery ranged from 1 to 24 months (median 4). Nineteen of 35 large grade III to V AVMs were possible to treat by radiosurgery following embolization. In the 46 patients complications occurred in 9 from embolization and in 2 from radiosurgery. Two patients had transient and 9 had permanent neurologic deficits. It is concluded that embolization facilitates radiosurgery for some large AVMs and therefore this combined treatment has a role in the management of AVMs. (orig.)

  13. A multi-national report on methods for institutional credentialing for spine radiosurgery

    International Nuclear Information System (INIS)

    Gerszten, Peter C; Shin, John H; Winey, Brian; Oh, Kevin; Sweeney, Reinhart A; Guckenberger, Matthias; Sahgal, Arjun; Sheehan, Jason P; Kersh, Ronald; Chen, Stephanie; Flickinger, John C; Quader, Mubina; Fahim, Daniel; Grills, Inga

    2013-01-01

    Stereotactic body radiotherapy and radiosurgery are rapidly emerging treatment options for both malignant and benign spine tumors. Proper institutional credentialing by physicians and medical physicists as well as other personnel is important for the safe and effective adoption of spine radiosurgery. This article describes the methods for institutional credentialing for spine radiosurgery at seven highly experienced international institutions. All institutions (n = 7) are members of the Elekta Spine Radiosurgery Research Consortium and have a dedicated research and clinical focus on image-guided spine radiosurgery. A questionnaire consisting of 24 items covering various aspects of institutional credentialing for spine radiosurgery was completed by all seven institutions. Close agreement was observed in most aspects of spine radiosurgery credentialing at each institution. A formal credentialing process was believed to be important for the implementation of a new spine radiosurgery program, for patient safety and clinical outcomes. One institution has a written policy specific for spine radiosurgery credentialing, but all have an undocumented credentialing system in place. All institutions rely upon an in-house proctoring system for the training of both physicians and medical physicists. Four institutions require physicians and medical physicists to attend corporate sponsored training. Two of these 4 institutions also require attendance at a non-corporate sponsored academic society radiosurgery course. Corporate as well as non-corporate sponsored training were believed to be complimentary and both important for training. In 5 centers, all cases must be reviewed at a multidisciplinary conference prior to radiosurgery treatment. At 3 centers, neurosurgeons are not required to be involved in all cases if there is no evidence for instability or spinal cord compression. Backup physicians and physicists are required at only 1 institution, but all institutions have more

  14. Clinical practice of image-guided spine radiosurgery - results from an international research consortium

    Directory of Open Access Journals (Sweden)

    Guckenberger Matthias

    2011-12-01

    Full Text Available Abstract Background Spinal radiosurgery is a quickly evolving technique in the radiotherapy and neurosurgical communities. However, the methods of spine radiosurgery have not been standardized. This article describes the results of a survey about the methods of spine radiosurgery at five international institutions. Methods All institutions are members of the Elekta Spine Radiosurgery Research Consortium and have a dedicated research and clinical focus on image-guided radiosurgery. The questionnaire consisted of 75 items covering all major steps of spine radiosurgery. Results Strong agreement in the methods of spine radiosurgery was observed. In particular, similarities were observed with safety and quality assurance playing an important role in the methods of all institutions, cooperation between neurosurgeons and radiation oncologists in case selection, dedicated imaging for target- and organ-at-risk delineation, application of proper safety margins for the target volume and organs-at-risk, conformal planning and precise image-guided treatment delivery, and close clinical and radiological follow-up. In contrast, three major areas of uncertainty and disagreement were identified: 1 Indications and contra-indications for spine radiosurgery; 2 treatment dose and fractionation and 3 tolerance dose of the spinal cord. Conclusions Results of this study reflect the current practice of spine radiosurgery in large academic centers. Despite close agreement was observed in many steps of spine radiosurgery, further research in form of retrospective and especially prospective studies is required to refine the details of spinal radiosurgery in terms of safety and efficacy.

  15. Linear accelerator radiosurgery in treatment of central neurocytomas

    International Nuclear Information System (INIS)

    Martin, J.M.; Katati, M.; Arjona, V.; Lopez, E.; Olivares, G.; Hernandez, V.; Bullejos, J.A.; Arregui, G.; Busquier, H.; Minguez, A.

    2003-01-01

    The purpose of this report was to review our experience with stereotactic radiosurgery in the management of patients with residual neurocytomas after initial surgery. Between October 1996 and December 2001, four patients with central neurocytoma were treated by surgery and subsequently underwent linear accelerator (LINAC) radiosurgery. Two of the patients were cured, one exhibited a significant reduction in tumour size and the fourth remains stable. All four patients are alive and well. In cases of small residual tumours or recurrences radio-surgery allows open surgery to be avoided and is a safe and potentially effective approach. (author)

  16. Robotic radiosurgery. Treating tumors that move with respiration

    International Nuclear Information System (INIS)

    Urschel, Harold C. Jr.; Kresl, John J.; Luketich, James D.; Papiez, Lech; Timmerman, Robert D.; Schulz, Raymond A.

    2007-01-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife registered Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife using a

  17. Robotic radiosurgery. Treating tumors that move with respiration

    Energy Technology Data Exchange (ETDEWEB)

    Urschel, Harold C. Jr. [Baylor University Medical Center, Dallas, TX (United States). Chair of Cardiovascular and Thoracic Surgical Research, Education and Clinical Excellence; Kresl, John J. [Arizona Oncology Services at St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiation Oncology; Luketich, James D. [University of Pittsburgh Medical Center PUH, Pittsburgh, PA (United States). The Heart, Lung and Esophageal Surgery Inst.; Papiez, Lech; Timmerman, Robert D. [University of Texas Southwestern Medical Center, Dallas, TX (United States). Dept. of Radiation Oncology; Schulz, Raymond A. (eds.)

    2007-07-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife {sup registered} Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the Cyber

  18. The development of GPU-based parallel PRNG for Monte Carlo applications in CUDA Fortran

    Directory of Open Access Journals (Sweden)

    Hamed Kargaran

    2016-04-01

    Full Text Available The implementation of Monte Carlo simulation on the CUDA Fortran requires a fast random number generation with good statistical properties on GPU. In this study, a GPU-based parallel pseudo random number generator (GPPRNG have been proposed to use in high performance computing systems. According to the type of GPU memory usage, GPU scheme is divided into two work modes including GLOBAL_MODE and SHARED_MODE. To generate parallel random numbers based on the independent sequence method, the combination of middle-square method and chaotic map along with the Xorshift PRNG have been employed. Implementation of our developed PPRNG on a single GPU showed a speedup of 150x and 470x (with respect to the speed of PRNG on a single CPU core for GLOBAL_MODE and SHARED_MODE, respectively. To evaluate the accuracy of our developed GPPRNG, its performance was compared to that of some other commercially available PPRNGs such as MATLAB, FORTRAN and Miller-Park algorithm through employing the specific standard tests. The results of this comparison showed that the developed GPPRNG in this study can be used as a fast and accurate tool for computational science applications.

  19. The development of GPU-based parallel PRNG for Monte Carlo applications in CUDA Fortran

    Energy Technology Data Exchange (ETDEWEB)

    Kargaran, Hamed, E-mail: h-kargaran@sbu.ac.ir; Minuchehr, Abdolhamid; Zolfaghari, Ahmad [Department of nuclear engineering, Shahid Behesti University, Tehran, 1983969411 (Iran, Islamic Republic of)

    2016-04-15

    The implementation of Monte Carlo simulation on the CUDA Fortran requires a fast random number generation with good statistical properties on GPU. In this study, a GPU-based parallel pseudo random number generator (GPPRNG) have been proposed to use in high performance computing systems. According to the type of GPU memory usage, GPU scheme is divided into two work modes including GLOBAL-MODE and SHARED-MODE. To generate parallel random numbers based on the independent sequence method, the combination of middle-square method and chaotic map along with the Xorshift PRNG have been employed. Implementation of our developed PPRNG on a single GPU showed a speedup of 150x and 470x (with respect to the speed of PRNG on a single CPU core) for GLOBAL-MODE and SHARED-MODE, respectively. To evaluate the accuracy of our developed GPPRNG, its performance was compared to that of some other commercially available PPRNGs such as MATLAB, FORTRAN and Miller-Park algorithm through employing the specific standard tests. The results of this comparison showed that the developed GPPRNG in this study can be used as a fast and accurate tool for computational science applications.

  20. Value of gamma knife radiosurgery for tumors invading cavernous sinus

    International Nuclear Information System (INIS)

    Jokura, Hidefumi; Yoshimoto, Takashi

    1999-01-01

    The usefulness of radiosurgery for cavernous sinus tumors was evaluated based on our experience and recent published reports from other institutes. Twenty-six meningiomas involving the cavernous sinus were treated by radiosurgery. The length of follow-up average 3 years. Tumors regressed in 40% and remained stable in 56% of cases. A total of 96% of the tumors were controlled with only a few minor complications. We believe surgical resection to reduce the volume of the tumor without causing new neurological deficits, followed by radiosurgery on the tumor located in the cavernous sinus is the best choice in many cases. Twenty-five pituitary adenomas with cavernous sinus invasion were treated by a combination of transsphenoidal removal and radiosurgery. All the tumors are controlled in terms of volume during the follow-up (average of 34 months). There were no new neurological deficits, including visual disturbance. Hormone elevation was able to be corrected at an early stage without pituitary insufficiency more by radiosurgery than by fractionated radiation. However, to obtain good results by radiosurgery, it must be preceded by complete surgical decompression of optic nerves and chiasma from the tumor. (author)

  1. Hybrid SN/Monte Carlo research and results

    International Nuclear Information System (INIS)

    Baker, R.S.

    1993-01-01

    The neutral particle transport equation is solved by a hybrid method that iteratively couples regions where deterministic (S N ) and stochastic (Monte Carlo) methods are applied. The Monte Carlo and S N regions are fully coupled in the sense that no assumption is made about geometrical separation or decoupling. The hybrid Monte Carlo/S N method provides a new means of solving problems involving both optically thick and optically thin regions that neither Monte Carlo nor S N is well suited for by themselves. The hybrid method has been successfully applied to realistic shielding problems. The vectorized Monte Carlo algorithm in the hybrid method has been ported to the massively parallel architecture of the Connection Machine. Comparisons of performance on a vector machine (Cray Y-MP) and the Connection Machine (CM-2) show that significant speedups are obtainable for vectorized Monte Carlo algorithms on massively parallel machines, even when realistic problems requiring variance reduction are considered. However, the architecture of the Connection Machine does place some limitations on the regime in which the Monte Carlo algorithm may be expected to perform well

  2. Radiosurgery for pituitary adenomas; Radiocirurgia nos adenomas hipofisarios

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Douglas Guedes de; Salvajoli, Joao Victor; Canteras, Miguel Montes; Cecilio, Soraya A. Jorge [Instituto de Radiocirurgia Neurologica, Sao Paulo, SP (Brazil)]. E-mail: dougguedes@uol.com.br

    2006-12-15

    Pituitary adenomas represent nearly 15% of all intracranial tumors. Multimodal treatment includes microsurgery, medical management and radiotherapy. Microsurgery is the primary recommendation for nonfunctioning and most of functioning adenomas, except for prolactinomas that are usually managed with dopamine agonist drugs. However, about 30% of patients require additional treatment after microsurgery for recurrent or residual tumors. In these cases, fractionated radiation therapy has been the traditional treatment. More recently, radiosurgery has been established as a treatment option. Radiosurgery allows the delivery of prescribed dose with high precision strictly to the target and spares the surrounding tissues. Therefore, the risks of hypopituitarism, visual damage and vasculopathy are significantly lower. Furthermore, the latency of the radiation response after radiosurgery is substantially shorter than that of fractionated radiotherapy. The goal of this review is to define the efficacy, safety and role of radiosurgery for treatment of pituitary adenomas and to present the preliminary results of our institution. (author)

  3. Stereotactic radiosurgery: incision less surgery

    International Nuclear Information System (INIS)

    Alvarez, Victor M.; Palma, Raul B.

    1997-01-01

    Stereotactic Radiosurgery (SRS) involves the application of focused high dose, high energy radiation to precisely (stereotactically) localized targets in the head without opening the skull for the purpose of destroying pathologic tissues like tumors, and also for producing discrete lesions for the relief of certain functional disorders. This procedure was pioneered by Lars Leksel in the 1950s and has progressively been refined with the development of more powerful computer technology and more precise and safer radiation delivery systems. The used of the Linear Accelerator (LINAC)- based radiosurgery system would be the most cost-effective and appropriate system for this treatment

  4. Hybrid and Parallel Domain-Decomposition Methods Development to Enable Monte Carlo for Reactor Analyses

    International Nuclear Information System (INIS)

    Wagner, John C.; Mosher, Scott W.; Evans, Thomas M.; Peplow, Douglas E.; Turner, John A.

    2010-01-01

    This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform real commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the gold standard for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method, which

  5. Hybrid and parallel domain-decomposition methods development to enable Monte Carlo for reactor analyses

    International Nuclear Information System (INIS)

    Wagner, J.C.; Mosher, S.W.; Evans, T.M.; Peplow, D.E.; Turner, J.A.

    2010-01-01

    This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform 'real' commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the 'gold standard' for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method

  6. Parallel processing Monte Carlo radiation transport codes

    International Nuclear Information System (INIS)

    McKinney, G.W.

    1994-01-01

    Issues related to distributed-memory multiprocessing as applied to Monte Carlo radiation transport are discussed. Measurements of communication overhead are presented for the radiation transport code MCNP which employs the communication software package PVM, and average efficiency curves are provided for a homogeneous virtual machine

  7. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael

    2006-01-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle 3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 μm are generated for field size below 2 x 2 cm 2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle 3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam

  8. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    Science.gov (United States)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael

    2006-05-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.

  9. International Radiosurgery Support Association

    Science.gov (United States)

    ... below: ? Brain Tumors Brain Disorders AVMs Radiosurgery Gamma Knife Linac Radiotherapy Overview Childhood Brain Tumors Radiation Therapy Radiation Injury Treatment Day Making a Decision Centers of Excellence BRAIN TALK® ...

  10. TU-AB-BRC-12: Optimized Parallel MonteCarlo Dose Calculations for Secondary MU Checks

    Energy Technology Data Exchange (ETDEWEB)

    French, S; Nazareth, D [Roswell Park Cancer Institute, Buffalo, NY (United States); Bellor, M [Lockheed Martin, Manassas, VA (United States)

    2016-06-15

    Purpose: Secondary MU checks are an important tool used during a physics review of a treatment plan. Commercial software packages offer varying degrees of theoretical dose calculation accuracy, depending on the modality involved. Dose calculations of VMAT plans are especially prone to error due to the large approximations involved. Monte Carlo (MC) methods are not commonly used due to their long run times. We investigated two methods to increase the computational efficiency of MC dose simulations with the BEAMnrc code. Distributed computing resources, along with optimized code compilation, will allow for accurate and efficient VMAT dose calculations. Methods: The BEAMnrc package was installed on a high performance computing cluster accessible to our clinic. MATLAB and PYTHON scripts were developed to convert a clinical VMAT DICOM plan into BEAMnrc input files. The BEAMnrc installation was optimized by running the VMAT simulations through profiling tools which indicated the behavior of the constituent routines in the code, e.g. the bremsstrahlung splitting routine, and the specified random number generator. This information aided in determining the most efficient compiling parallel configuration for the specific CPU’s available on our cluster, resulting in the fastest VMAT simulation times. Our method was evaluated with calculations involving 10{sup 8} – 10{sup 9} particle histories which are sufficient to verify patient dose using VMAT. Results: Parallelization allowed the calculation of patient dose on the order of 10 – 15 hours with 100 parallel jobs. Due to the compiler optimization process, further speed increases of 23% were achieved when compared with the open-source compiler BEAMnrc packages. Conclusion: Analysis of the BEAMnrc code allowed us to optimize the compiler configuration for VMAT dose calculations. In future work, the optimized MC code, in conjunction with the parallel processing capabilities of BEAMnrc, will be applied to provide accurate

  11. The study on linac stereotactic radiosurgery for acoustic tumors

    International Nuclear Information System (INIS)

    Ohishi, Hitoshi

    1995-01-01

    We have designed and manufactured a new type of device for stereotactic radiosurgery characterized by the combined use of a rotatory chair and a linear accelerator. In this study, 20 acoustic tumors treated by our modality were evaluated by serial neuroimaging, neurofunctional outcome and, in a few cases, pathological findings of surgical specimens. Because tumor size usually changed very slowly after radiosurgery, 12 cases that had a minimum of 12 months of follow-up were employed in the analysis of tumor size. Serial neuroimaging studies revealed the reduction of tumor size in 3 cases and prevention of tumor growth in 7 cases, therefore, the rate of tumor control was evaluated as 83%. Growth of tumor size occurred in 3 cases, two were cases harbouring a large cyst in the tumor and another was a case of neurofibromatosis type 2. In 13 cases (68%), loss of the gadolinium enhancement effect inside the tumor was observed. This is a characteristic change after radiosurgery for acoustic tumors, and attributable to a necrotic change. Cranial nerve neuropathies as a complication also occurred (facial nerve palsy in 2 and trigeminal nerve dysfunction in 1). Adjacent parenchymal change appeared in 1 case. This patient had two prior operations and the tumor had an irregular shape, therefore, planning for radiosurgery encountered some difficulty. Hydrocephalus occurred in 1 case. Surgical specimens in 2 cases in which microsurgery was undertaken for growing tumors, revealed a necrotic tumor tissue and proliferation of fibrous tissue. In conclusion, our new device for stereotactic radiosurgery is particularly useful for the treatment of acoustic tumors. Similar therapeutic results of the gamma knife have been achieved. Radiosurgery is a recommendable treatment for acoustic tumors. However, the superiority of radiosurgery over microsurgery is still controversial and needs a longer term follow-up and multivariate analysis for a final conclusion. (author)

  12. Treatment of epidermoid tumors with gamma knife radiosurgery: Case series.

    Science.gov (United States)

    Vasquez, Javier A Jacobo; Fonnegra, Julio R; Diez, Juan C; Fonnegra, Andres

    2016-01-01

    Epidermoid tumors (ETs) are benign lesions that are treated mainly by means of surgical resection, with overall good results. External beam radiotherapy is an alternative treatment for those recurrent tumors, in which a second surgery might not be the best choice for the patient. A little information exists about the effectiveness of gamma knife radiosurgery for the treatment of newly diagnosed and recurrent ETs. We present three cases of ETs treated with gamma knife radiosurgery. Case 1 is a 21-year-old female with an ET located in the left cerebellopontine angle (CPA) with symptoms related to VIII cranial nerve dysfunction. Symptom control was achieved and maintained after single session radiosurgery with gamma knife. Case 2 is a 59-year-old female patient with the history of trigeminal neuralgia secondary to a recurrent ET located in the left CPA. Significant pain improvement was achieved after treatment with gamma knife radiosurgery. Case 3 is a 29-year-old male patient with a CPA ET causing long lasting trigeminal neuralgia, pain relief was achieved in this patient after gamma knife radiosurgery. Long-term symptom relief was achieved in all three cases proving that gamma knife radiosurgery is a good and safe alternative for patients with recurrent or nonsurgically treated ETs.

  13. Spatial updating grand canonical Monte Carlo algorithms for fluid simulation: generalization to continuous potentials and parallel implementation.

    Science.gov (United States)

    O'Keeffe, C J; Ren, Ruichao; Orkoulas, G

    2007-11-21

    Spatial updating grand canonical Monte Carlo algorithms are generalizations of random and sequential updating algorithms for lattice systems to continuum fluid models. The elementary steps, insertions or removals, are constructed by generating points in space either at random (random updating) or in a prescribed order (sequential updating). These algorithms have previously been developed only for systems of impenetrable spheres for which no particle overlap occurs. In this work, spatial updating grand canonical algorithms are generalized to continuous, soft-core potentials to account for overlapping configurations. Results on two- and three-dimensional Lennard-Jones fluids indicate that spatial updating grand canonical algorithms, both random and sequential, converge faster than standard grand canonical algorithms. Spatial algorithms based on sequential updating not only exhibit the fastest convergence but also are ideal for parallel implementation due to the absence of strict detailed balance and the nature of the updating that minimizes interprocessor communication. Parallel simulation results for three-dimensional Lennard-Jones fluids show a substantial reduction of simulation time for systems of moderate and large size. The efficiency improvement by parallel processing through domain decomposition is always in addition to the efficiency improvement by sequential updating.

  14. Stereotactic radiosurgery in acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki; Noren, G. (Karolinska Hospital, Stockholm (Sweden))

    1990-12-01

    The records of 57 patients with 61 acoustic neurinomas treated with stereotatic radiosurgery at the Karolinska Hospital, Stockholm, from 1982 through 1984, were reviewed. Adequate radiological and clinical follow-up evaluations were available in these cases. An additional 8 patients were treated during this same period but were not included because of insufficient data. The tumors were evaluated with CT or MRI. Their post-operative follow-up period was 6-66 months (mean 28 months). Decrease of tumor size or no change was considered as a response to radiosurgery. This was found in 54 (88%) of the tumors. Small tumors with a diameter of less than 15 mm responded better (93%) than large ones (85%). Ninety-five percent of unilateral tumors and 74% of tumors associated with neurofibromatosis responded well. Seven tumors had definite radiographic signs of subsequent growth. Four were removed using standard microsurgical tequniques and three have so far not required further treatment. Facial and trigeminal nerve function was evaluated in 58 facial surfaces where tumors had been irradiated. Transient facial weakness developed in 9% and facial hypesthesia in 9% of the irradiated cases. The onset of these nerve dysfunction appeared with a latency period of 4 to 15 months after radiosurgery. Excluding the ears which had been totally deaf before the treatment, forty-one ears were evaluated fully by audiometry prior to and one year after irradiation. 30% of them had no change in hearing, 68% had a more or less pronouced deterioration and 2% had improvement. We regard efficiency in arresting tumor growth without endangering life, preservation of facial nerve function, and only a day of hospitalization as major benefits of radiosurgery. (author).

  15. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Dieterich, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  16. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Dieterich, S. [UC Davis Medical Center (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  17. The strategy of the treatment for arteriovenous malformations by gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Fukuoka, Seiji; Seo, Yoshinobu; Hyougo, Toshio; Sasaki, Takehiko; Toshima, Masahiko; Takeda, Rihei; Nakamura, Junichi; Suematu, Katsumi.

    1992-01-01

    Successful gamma knife radiosurgery depends on the volume of nidus of cerebral arteriovenous malformations (AVMs). Because of lower possibility of obliteration of large AVMs treated by gamma knife radiosurgery, embolization therapies were carried out in 10 cases out of 50 AVMs to reduce the volume of nidus before gamma knife radiosurgery. The strategy is as follows: 1) when the volume of nidus is less than 5 ml, gamma knife radiosurgery is selected as the first treatment; 2) when the procedure seems to be safely performed; 3) when the volume of nidus is over 10 ml, embolization should be tried in all cases. In this strategy, it is essential to evaluate the accurate volume of nidus before gamma knife radiosurgery to decide whether embolization should be carried out or not. Angiography with painless fixation of Leksell frame was thought to be best procedure to measure the accurate volume of nidus before gamma knife radiosurgery. (author)

  18. TU-H-CAMPUS-TeP1-03: Magnetically Focused Proton Irradiation of Small Volume Radiosurgery Targets

    Energy Technology Data Exchange (ETDEWEB)

    McAuley, GA; Slater, JM [Loma Linda University, Loma Linda, CA (United States); Wroe, AJ [Loma Linda University, Loma Linda, CA (United States); Loma Linda University Medical Center, Loma Linda, CA (United States)

    2016-06-15

    Purpose: To investigate the use of magnetic focusing for small volume proton radiosurgery targets using a triplet combination of quadrupole rare earth permanent magnet Halbach cylinder assemblies Methods: Fourteen quadrupole magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into k=3 Halbach cylinders with various field gradients (100 to 250 T/m) were designed and manufactured. Triplet combinations of the magnets were placed on a positioning track on our Gantry 1 treatment table. Unmodulated 127 MeV proton beams with initial diameters of 3 to 20 mm were delivered to a water tank using single-stage scattering. Depth and transverse dose distributions were measured using a PTW PR60020 diode detector and EBT3 film, respectively. This data was compared with unfocused passively collimated beams. Monte Carlo simulations were also performed - both for comparison with experimental data and to further investigate the potential of triplet magnetic focusing. Results: Experimental results using 150 T/m gradient magnets and 15 to 20 mm initial diameter beams show peak to entrance dose ratios that are ∼ 43 to 48 % larger compared with spot size matched 8 mm collimated beams (ie, transverse profile full-widths at 90% maximum dose match within 0.5 mm of focused beams). In addition, the focusing beams were ∼ 3 to 4.4 times more efficient per MU in dose to target delivery. Additional results using different magnet combinations will also be presented. Conclusion: Our results suggest that triplet magnetic focusing could reduce entrance dose and beam number while delivering dose to small (∼≤ 10 mm diameter) radiosurgery targets in less time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however other treatment sites can be also envisioned. This project was sponsored with funding from the Department of Defense (DOD# W81XWH-BAA-10-1).

  19. Stereotactic Radiosurgery - Gamma Knife

    Science.gov (United States)

    ... DE, Adler JR Jr, Ewend MG. Image-guided robotic radiosurgery. In: Winn RH, ed. Youmans Neurological Surgery . ... by URAC, also known as the American Accreditation HealthCare Commission (www.urac.org). URAC's accreditation program is ...

  20. Comparison of measured and Monte Carlo calculated dose distributions from circular collimators for radiosurgical beams

    International Nuclear Information System (INIS)

    Esnaashari, K. N.; Allahverdi, M.; Gharaati, H.; Shahriari, M.

    2007-01-01

    Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta 'Synergy S' as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at iso centre using the BEAM/EGS4 Monte Carlo code. Materials and Methods: The linear accelerator Elekta Synergy S equipped with a set of 5 circular collimators from 10 mm to 50 mm in diameter at iso centre distance was used. The cones were inserted in a base plate mounted on the collimator linac head. A PinPoint chamber and Wellhofer water tank chamber were selected for clinical dosimetry of 6 MV photon beams. The results of simulations using the Monte Carlo system BEAM/EGS4 to model the beam geometry were compared with dose measurements. Results: An excellent agreement was found between Monte Carlo calculated and measured percentage depth dose and lateral dose profiles which were performed in water phantom for circular cones with 1, 2, 3, 4 and 5 cm in diameter. The comparison between calculation and measurements showed up to 0.5 % or 1 m m difference for all field sizes. The penumbra (80-20%) results at 5 cm depth in water phantom and SSD=95 ranged from 1.5 to 2.1 mm for circular collimators with diameter 1 to 5 cm. Conclusion: This study showed that BEAMnrc code has been accurate in modeling Synergy S linear accelerator equipped with circular collimators

  1. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  2. Performance analysis of a parallel Monte Carlo code for simulating solar radiative transfer in cloudy atmospheres using CUDA-enabled NVIDIA GPU

    Science.gov (United States)

    Russkova, Tatiana V.

    2017-11-01

    One tool to improve the performance of Monte Carlo methods for numerical simulation of light transport in the Earth's atmosphere is the parallel technology. A new algorithm oriented to parallel execution on the CUDA-enabled NVIDIA graphics processor is discussed. The efficiency of parallelization is analyzed on the basis of calculating the upward and downward fluxes of solar radiation in both a vertically homogeneous and inhomogeneous models of the atmosphere. The results of testing the new code under various atmospheric conditions including continuous singlelayered and multilayered clouds, and selective molecular absorption are presented. The results of testing the code using video cards with different compute capability are analyzed. It is shown that the changeover of computing from conventional PCs to the architecture of graphics processors gives more than a hundredfold increase in performance and fully reveals the capabilities of the technology used.

  3. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  4. CyberKnife radiosurgery: Precision without incision

    Directory of Open Access Journals (Sweden)

    Enja Siva Prasad Reddy

    2015-01-01

    Full Text Available CyberKnife stereotactic radiosurgery system is an innovative, effective, frameless, non-invasive substitute for conventional surgical treatment of cancer. It works on the principle of stereotaxy. It is used for the treatment of both cancerous and non-cancerous tumors, intracranial lesions, tumors of lung, spine, prostate, and kidney, recurrent cases of oral squamous cell carcinoma, arteriovenous malformation, and trigeminal neuralgia. It has an advantage over other systems like Gamma knife radiosurgery and linear accelerator (LINAC-based systems, as it is frameless, has submillimeter accuracy, does not affect the normal cells adjacent to the lesion, and tracks the lesion in synchronization with the patient′s respiratory rate. The future of CyberKnife encompasses possibilities such as incremental improvements in accuracy and better shaping of the field of radiation and would certainly allow extension of radiosurgery as an effective substitute for chemotherapy. This paper aims to review and highlight the immense potential that CyberKnife holds in the field of dentistry in treating disorders of the head and neck region, thereby ensuring enhanced longevity for the patients.

  5. WE-A-304-00: Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  6. WE-A-304-00: Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  7. An inherently parallel method for solving discretized diffusion equations

    International Nuclear Information System (INIS)

    Eccleston, B.R.; Palmer, T.S.

    1999-01-01

    A Monte Carlo approach to solving linear systems of equations is being investigated in the context of the solution of discretized diffusion equations. While the technique was originally devised decades ago, changes in computer architectures (namely, massively parallel machines) have driven the authors to revisit this technique. There are a number of potential advantages to this approach: (1) Analog Monte Carlo techniques are inherently parallel; this is not necessarily true to today's more advanced linear equation solvers (multigrid, conjugate gradient, etc.); (2) Some forms of this technique are adaptive in that they allow the user to specify locations in the problem where resolution is of particular importance and to concentrate the work at those locations; and (3) These techniques permit the solution of very large systems of equations in that matrix elements need not be stored. The user could trade calculational speed for storage if elements of the matrix are calculated on the fly. The goal of this study is to compare the parallel performance of Monte Carlo linear solvers to that of a more traditional parallelized linear solver. The authors observe the linear speedup that they expect from the Monte Carlo algorithm, given that there is no domain decomposition to cause significant communication overhead. Overall, PETSc outperforms the Monte Carlo solver for the test problem. The PETSc parallel performance improves with larger numbers of unknowns for a given number of processors. Parallel performance of the Monte Carlo technique is independent of the size of the matrix and the number of processes. They are investigating modifications to the scheme to accommodate matrix problems with positive off-diagonal elements. They are also currently coding an on-the-fly version of the algorithm to investigate the solution of very large linear systems

  8. Factors Determining the Clinical Complications of Radiosurgery for AVM.

    Science.gov (United States)

    Machnowska, Matylda; Taeshineetanakul, Patamintita; Geibprasert, Sasikhan; Menezes, Ravi; Agid, Ronit; Terbrugge, Karel G; Andrade-Souza, Yuri; Schwartz, Michael L; Krings, Timo

    2013-11-01

    To identify the predictors of symptomatic post-radiation T2 signal change in patients with arteriovenous malformations (AVM) treated with radiosurgery. The charts of 211 consecutive patients with arteriovenous malformations treated with either gamma knife radisurgery or linear accelerator radiosurgery between 2000-2009 were retrospectively reviewed. 168 patients had a minimum of 12 months of clinical and radiologic follow-up following the procedure and complete dosage data. Pretreatment characteristics and dosimetric variables were analyzed to identify predictors of adverse radiation effects. 141 patients had no clinical symptomatic complications. 21 patients had global or focal neurological deficits attributed to symptomatic edema. Variables associated with development of symptomatic edema included a non-hemorrhagic symptomatic presentation compared to presentation with hemorrhage, p=0.001; OR (95%CI) = 6.26 (1.99, 19.69); the presence of venous rerouting compared to the lack of venous rerouting, p=0.031; OR (95% CI) = 3.25 (1.20, 8.80); radiosurgery with GKS compared to linear accelerator radiosurgery p = 0.012; OR (95% CI) = 4.58 (1.28, 16.32); and the presence of more than one draining vein compared to a single draining vein p = 0.032; OR (95% CI) = 2.82 (1.06, 7.50). We postulated that the higher maximal doses used with gamma knife radiosurgery may be responsible for the greater number of adverse radiation effects with this modality compared to linear accelerator radiosurgery. We found that AVMs with greater venous complexity and therefore instability resulted in more adverse treatment outcomes, suggesting that AVM angioarchitecture should be considered when making treatment decisions. Facteurs en cause dans les complications cliniques de la radiochirurgie pour une malformation artérioveineuse.

  9. The rationale and technique of staged-volume arteriovenous malformation radiosurgery

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Kline, Robert W.; Stafford, Scott L.; Foote, Robert L.; Schomberg, Paula J.

    2000-01-01

    Purpose: Stereotactic radiosurgery is an effective management strategy for properly selected arteriovenous malformation (AVM) patients. However, the risk of postradiosurgical radiation-related injury generally limits this procedure to patients with AVMs of an average diameter of 3 cm or less. Radiosurgery of large AVMs in a planned staged fashion was undertaken to limit the radiation exposure to the surrounding normal brain. Methods and Materials: Between April 1997 and December 1999, 10 patients with a median AVM volume of 17.4 cm 3 (range, 7.4-53.3 cm 3 ) underwent staged-volume radiosurgery (23 procedures). At the first radiosurgical procedure, the total volume of the AVM is estimated and a dose plan calculated that covers 10 cm 3 -15 cm 3 , or one-half the nidus volume if the AVM is critically located (brainstem, thalamus, or basal ganglia). At 6-month intervals thereafter, radiosurgery was repeated to different portions of the AVM with the previous dose plan(s) being re-created utilizing intracranial landmarks to minimize radiation overlap. Radiosurgical procedures were continued until the entire malformation has been irradiated. Results: The radiation dosimetry of staged-volume AVM radiosurgery was compared to hypothetical single-session procedures for the 10 patients. Staged-volume radiosurgery decreased the 12-Gy volume by an average of 11.1% (range, 4.9-21%) (p < 0.001). The non-AVM 12-Gy volume was reduced by an average of 27.2% (range, 12.5-51.3%) (p < 0.001). Discussion: Staged-volume radiosurgery of large AVMs results in less radiation exposure to the adjacent brain. Further follow-up is needed to determine whether this technique provides a high rate of AVM obliteration while maintaining an acceptable rate of radiation-related complications

  10. Multileaf collimator-based linear accelerator radiosurgery: five-year efficiency analysis.

    Science.gov (United States)

    Lawson, Joshua D; Fox, Tim; Waller, Anthony F; Davis, Lawrence; Crocker, Ian

    2009-03-01

    In 1989, Emory University initiated a linear accelerator (linac) radiosurgery program using circular collimators. In 2001, the program converted to a multileaf collimator. Since then, the treatment parameters of each patient have been stored in the record-and-verify system. Three major changes have occurred in the radiosurgery program in the past 6 years: in 2002, treatment was changed from static conformal beams to dynamic conformal arc (DCA) therapy, and all patients were imaged before treatment. Beginning in 2005, a linac was used, with the opportunity to treat at higher dose rates (600-1,000 monitor units/min). The aim of this study was to analyze the time required to deliver radiosurgery and the factors affecting treatment delivery. Benchmark data are provided for centers contemplating initiating linac radiosurgery programs. Custom software was developed to mine the record-and-verify system database and automatically perform a chart review on patients who underwent stereotactic radiosurgery from March 2001 to October 2006. The software extracted 510 patients who underwent stereotactic radiosurgery, and the following information was recorded for each patient: treatment technique, treatment time (from initiation of imaging, if done, to completion of therapy), number of isocenters, number of fields, total monitor units, and dose rate. Of the 510 patients, 395 were treated with DCA therapy and 115 with static conformal beams. The average number of isocenters treated was 1.06 (range, 1-4). The average times to deliver treatment were 24.1 minutes for patients who underwent DCA therapy and 19.3 minutes for those treated with static conformal beams, reflecting the lack of imaging in the latter patients. Eighty percent of patients were treated in question the need for a dedicated radiosurgery unit for even busy treatment centers.

  11. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, S. [San Diego Medical Physics (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  12. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    International Nuclear Information System (INIS)

    Goetsch, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  13. Gamma knife radiosurgery in movement disorders: Indications and limitations.

    Science.gov (United States)

    Higuchi, Yoshinori; Matsuda, Shinji; Serizawa, Toru

    2017-01-01

    Functional radiosurgery has advanced steadily during the past half century since the development of the gamma knife technique for treating intractable cancer pain. Applications of radiosurgery for intracranial diseases have increased with a focus on understanding radiobiology. Currently, the use of gamma knife radiosurgery to ablate deep brain structures is not widespread because visualization of the functional targets remains difficult despite the increased availability of advanced neuroimaging technology. Moreover, most existing reports have a small sample size or are retrospective. However, increased experience with intraoperative neurophysiological evaluations in radiofrequency thalamotomy and deep brain stimulation supports anatomical and neurophysiological approaches to the ventralis intermedius nucleus. Two recent prospective studies have promoted the clinical application of functional radiosurgery for movement disorders. For example, unilateral gamma knife thalamotomy is a potential alternative to radiofrequency thalamotomy and deep brain stimulation techniques for intractable tremor patients with contraindications for surgery. Despite the promising efficacy of gamma knife thalamotomy, however, these studies did not include sufficient follow-up to confirm long-term effects. Herein, we review the radiobiology literature, various techniques, and the treatment efficacy of gamma knife radiosurgery for patients with movement disorders. Future research should focus on randomized controlled studies and long-term effects. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  14. Optimization of Monte Carlo algorithms and ray tracing on GPUs

    International Nuclear Information System (INIS)

    Bergmann, R.M.; Vujic, J.L.

    2013-01-01

    To take advantage of the computational power of GPUs (Graphical Processing Units), algorithms that work well on CPUs must be modified to conform to the GPU execution model. In this study, typical task-parallel Monte Carlo algorithms have been reformulated in a data-parallel way, and the benefits of doing so are examined. We were able to show that the data-parallel approach greatly improves thread coherency and keeps thread blocks busy, improving GPU utilization compared to the task-parallel approach. Data-parallel does not, however, outperform the task-parallel approach in regards to speedup over CPU. Regarding the ray-tracing acceleration, OptiX shows promise for providing enough ray tracing speed to be used in a full 3D Monte Carlo neutron transport code for reactor calculations. It is important to note that it is necessary to operate on large datasets of particle histories in order to have good performance in both OptiX and the data-parallel algorithm since this reduces the impact of latency. Our paper also shows the need to rewrite standard Monte Carlo algorithms in order to take full advantage of these new, powerful processor architectures

  15. International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Spratt, Daniel E.; Lovelock, Michael; Bilsky, Mark H.; Lis, Eric; Ryu, Samuel; Sheehan, Jason; Gerszten, Peter C.; Chang, Eric; Gibbs, Iris; Soltys, Scott; Sahgal, Arjun; Deasy, Joe; Flickinger, John; Quader, Mubina; Mindea, Stefan

    2012-01-01

    Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic

  16. Stereotactic radiosurgery: basic concepts and current status

    International Nuclear Information System (INIS)

    Gaur, Maheep Singh

    2016-01-01

    Term Stereotactic Radiosurgery was coined by Prof Lars Leksell in 1951 as concept. Leksell's experimented together with the radiobiologist Borje Larsson in Uppsala, on trying to develop 'stereotactic radiosurgery', aimed at lesioning in the central brain in functional operations such as thalamotomy and capsulotomy. Clinical experiments using a proton beam were initiated at the Gustav Werner Institute in Uppsala, and a few patients had been treated. Experiences from these led Leksell to design a multi-source 'beam knife', which became ready for use in 1967 as the first 'Gamma Knife' and installed at the private hospital Sophiahammet in Stockholm as a clinical research unit. Moving from functional neurosurgery today Gamma knife is used for a wide range on brain tumors, vascular malformations and functional disorders. Introduction of newer technology in navigation and radiation delivery has made it possible to do whole body Radiosurgery. Various technologies, basic principles, radiobiological aspects and applications will be discussed. (author)

  17. Stereotactic radiosurgery in the palliative treatment of brain metastases

    International Nuclear Information System (INIS)

    Faria, Sergio L.; Souhami, Luis; Bahary, Jean-Paul; Clark, Brenda; Adamson, Nelson; Podgorsak, Ervin B.; Caron, Jean-Louis; Villemure, Jean-Guy; Olivier, Andre

    1995-01-01

    Between October, 1988 and November, 1993, 57 patients with metastatic brain disease underwent stereotactic radiosurgery at McGill University, canada. Four patients were excluded from this analysis leaving a total of 53 evaluable patients (with 57 lesions). Radiosurgery was performed with the dynamic rotation technique which uses an isocentric, 10 MV, linear accelerator. A median dose of 1,800 c Gy was given in a single session. In 89% of the cases radiosurgery was used after failure to conventional brain radiotherapy. With a median follow-up of 6 months, the response rate was 65% . Treatments were well tolerated and only 4 patients (7%) developed late complications related to the therapy, with one patient requiring a surgical resection of an area of radionecrose. Radiosurgery appears to be and effective and safe treatment for selected patients with metastatic brain disease, recurrent post-conventional radiotherapy. Its value as a single treatment modality for patients with isolated brain metastasis is now being studied in prospective trials. (author). 29 refs., 4 figs., 4 tabs

  18. Radiosurgery without whole brain radiotherapy in melanoma brain metastases

    International Nuclear Information System (INIS)

    Grob, J.J.; Regis, J.; Laurans, R.; Delaunay, M.; Wolkenstein, P.; Paul, K.; Souteyrand, P.; Koeppel, M.C.; Murraciole, X.; Perragut, J.C.; Bonerandi, J.J.

    1998-01-01

    To evaluate the effectiveness of radiosurgery without whole brain radiotherapy in the palliative treatment of melanoma brain metastases, we retrospectively assessed the results in 35 patients: 4 with a solitary brain metastasis, 13 with a single brain metastasis and metastases elsewhere and 18 with multiple brain metastases. The local control rate was 98.2% (55/56 metastases) at 3 months. Median survival was 22 months in patients with a solitary brain metastasis, 7.5 months in patients with a single brain metastasis and metastases elsewhere, and 4 months in patients with multiple brain metastases. Complications were unusual and surgery was required in 2 of 35 patients. These results show for the first time that melanoma patients with a unique brain metastasis with or without metastases elsewhere clearly benefit from tumour control easily obtained by radiosurgery. Although the comparison of radiosurgery with surgery and/or whole brain radiotherapy cannot be adequately addressed, radiosurgery alone seems to provide similar results with lower morbidity and impact on quality of life. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  19. A comparison of arc-based and static mini-multileaf collimator-based radiosurgery treatment plans

    International Nuclear Information System (INIS)

    Kubo, Hideo Dale; Pappas, Conrad T.E.; Wilder, Richard B.

    1997-01-01

    Background: The purpose of this study is to compare arc-based and mini-multileaf collimator (mMLC)-based radiosurgery treatment plans using isodose distributions and dose-volume histograms. Methods: Of 11 patients who underwent conventional arc-based radiosurgery for intracranial malignancies, four were treated with one isocenter, four were treated with two isocenters and three were treated with three isocenters. The same cases were re-planned using a test version of mMLC-based radiosurgery software for multiple static non-coplanar fields. Results and conclusion: For non-spherical targets, treatment planning is relatively intuitive with mMLC-based radiosurgery, reducing the amount of time required for planning. Moreover, a lower dose of radiation is delivered to normal tissue with mMLC-based radiosurgery than with arc-based radiosurgery, which theoretically should lead to a reduced risk of complications

  20. Introducing heterogeneity in Monte Carlo models for risk assessments of high-level nuclear waste. A parallel implementation of the MLCRYSTAL code

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, M.

    1996-09-01

    We have introduced heterogeneity to an existing model as a special feature and simultaneously extended the model from 1D to 3D. Briefly, the code generates stochastic fractures in a given geosphere. These fractures are connected in series to form one pathway for radionuclide transport from the repository to the biosphere. Rock heterogeneity is realized by simulating physical and chemical properties for each fracture, i.e. these properties vary along the transport pathway (which is an ensemble of all fractures serially connected). In this case, each Monte Carlo simulation involves a set of many thousands of realizations, one for each pathway. Each pathway can be formed by approx. 100 fractures. This means that for a Monte Carlo simulation of 1000 realizations, we need to perform a total of 100,000 simulations. Therefore the introduction of heterogeneity has increased the CPU demands by two orders of magnitude. To overcome the demand for CPU, the program, MLCRYSTAL, has been implemented in a parallel workstation environment using the MPI, Message Passing Interface, and later on ported to an IBM-SP2 parallel supercomputer. The program is presented here and a preliminary set of results is given with the conclusions that can be drawn. 3 refs, 12 figs.

  1. Introducing heterogeneity in Monte Carlo models for risk assessments of high-level nuclear waste. A parallel implementation of the MLCRYSTAL code

    International Nuclear Information System (INIS)

    Andersson, M.

    1996-09-01

    We have introduced heterogeneity to an existing model as a special feature and simultaneously extended the model from 1D to 3D. Briefly, the code generates stochastic fractures in a given geosphere. These fractures are connected in series to form one pathway for radionuclide transport from the repository to the biosphere. Rock heterogeneity is realized by simulating physical and chemical properties for each fracture, i.e. these properties vary along the transport pathway (which is an ensemble of all fractures serially connected). In this case, each Monte Carlo simulation involves a set of many thousands of realizations, one for each pathway. Each pathway can be formed by approx. 100 fractures. This means that for a Monte Carlo simulation of 1000 realizations, we need to perform a total of 100,000 simulations. Therefore the introduction of heterogeneity has increased the CPU demands by two orders of magnitude. To overcome the demand for CPU, the program, MLCRYSTAL, has been implemented in a parallel workstation environment using the MPI, Message Passing Interface, and later on ported to an IBM-SP2 parallel supercomputer. The program is presented here and a preliminary set of results is given with the conclusions that can be drawn. 3 refs, 12 figs

  2. Long-term effects of gamma knife radiosurgery for pediatric craniopharyngioma

    International Nuclear Information System (INIS)

    Osuka, Koji; Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Yoshida, Kazuo; Hasegawa, Toshinori

    2001-01-01

    Twenty-one pediatric patients with craniopharyngioma have undergone gamma knife radiosurgery at our facility since May 1991, and we have followed up 10 of these patients for at least 24 months (mean 44.5 months). The patients' ages ranged from 6 to 12 years (mean 8.6 years). Initial presentations were headache in 7 patients, decreased visual acuity in 8, visual field deficit in 5, hypopituitarism in 7, and diabetes insipidus in 3. Prior to radiosurgery, surgical procedures had been performed in 8 patients, conventional radiotherapy in 1, and chemotherapy in 1. Mean tumor diameter was 17.4 mm, and treatment was by gamma knife, with mean maximum and marginal doses of 25.4 Gy and 13.3 Gy, respectively. Follow-up MRI revealed good tumor control (partial response+complete response) in 7 of the 10 patients, with neither further neurological nor endocrinological deterioration. Two patients showed tumor shrinkage for 60 months and 46 months, respectively, after radiosurgery, while, thereafter, tumor gradually recurred at the side of the optic nerve. In one patient, rapid growth of the cyst was observed 6 months after radiosurgery. Gamma knife radiosurgery for pediatric craniopharyngioma is considered to be a safe and effective treatment after microsurgical tumor removal. In cases in which total removal is impossible, it is important to detach the tumor from the optic nerve and to reduce the tumor volume for gamma knife radiosurgery after microsurgery. If the tumor has a cystic component, this should be removed at the time of surgery. (author)

  3. Long-term effects of gamma knife radiosurgery for pediatric craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Osuka, Koji; Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Yoshida, Kazuo; Hasegawa, Toshinori [Komaki City Hospital, Aichi (Japan)

    2001-02-01

    Twenty-one pediatric patients with craniopharyngioma have undergone gamma knife radiosurgery at our facility since May 1991, and we have followed up 10 of these patients for at least 24 months (mean 44.5 months). The patients' ages ranged from 6 to 12 years (mean 8.6 years). Initial presentations were headache in 7 patients, decreased visual acuity in 8, visual field deficit in 5, hypopituitarism in 7, and diabetes insipidus in 3. Prior to radiosurgery, surgical procedures had been performed in 8 patients, conventional radiotherapy in 1, and chemotherapy in 1. Mean tumor diameter was 17.4 mm, and treatment was by gamma knife, with mean maximum and marginal doses of 25.4 Gy and 13.3 Gy, respectively. Follow-up MRI revealed good tumor control (partial response+complete response) in 7 of the 10 patients, with neither further neurological nor endocrinological deterioration. Two patients showed tumor shrinkage for 60 months and 46 months, respectively, after radiosurgery, while, thereafter, tumor gradually recurred at the side of the optic nerve. In one patient, rapid growth of the cyst was observed 6 months after radiosurgery. Gamma knife radiosurgery for pediatric craniopharyngioma is considered to be a safe and effective treatment after microsurgical tumor removal. In cases in which total removal is impossible, it is important to detach the tumor from the optic nerve and to reduce the tumor volume for gamma knife radiosurgery after microsurgery. If the tumor has a cystic component, this should be removed at the time of surgery. (author)

  4. Linac radiosurgery for high-grade gliomas: the University of Florida experience

    Energy Technology Data Exchange (ETDEWEB)

    Buatti, John M; Friedman, William A; Bova, Frank J; Mendenhall, William M

    1995-04-30

    Purpose: Stereotactic radiosurgery has been reported as a promising boost technique for the treatment of selected patients with high-grade glioma. The first 11 patients given this treatment at the University of Florida are reported. Methods and Materials: Six patients with glioblastoma multiforme and five with anaplastic astrocytoma were carefully selected for treatment with linac radiosurgery. All patients had a Karnofsky performance status {>=} 90%. Median age of patients was 42.1 years. External-beam radiotherapy delivered a median dose of 60 Gy. Stereotactic radiosurgery was delivered to the enhancing tumor volume without margin. Median treatment volume was 14 cm{sup 3} (equivalent sphere diameter, 3 cm). The maximum volume of any tumor treated was 22.5 cm{sup 3} (equivalent sphere diameter, 3.5 cm). Median stereotactic radiosurgery boost dose was 12.5 Gy, and median prescription sphere was the 80% isodose shell. Results: Despite rigorous selection and aggressive stereotactic boost irradiation, this patient cohort had a median actuarial survival of 17 months. All patients have had progression of intracranial disease within 1 year of radiosurgery, and only 3 of 11 remain alive with a median follow-up of 13 months. Conclusion: These results differ significantly from others reported. Comparative analysis suggests tumor volume may be an important prognostic factor in patients treated with stereotactic radiosurgery. Future studies need to define appropriate patient cohorts for the boost technique.

  5. The history of stereotactic radiosurgery and radiotherapy.

    Science.gov (United States)

    Lasak, John M; Gorecki, John P

    2009-08-01

    Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.

  6. Radiosurgery for acoustic neurinomas: Early experience

    International Nuclear Information System (INIS)

    Linskey, M.E.; Lunsford, L.D.; Flickinger, J.C.

    1990-01-01

    We reviewed our early experience with the first 26 patients with acoustic neurinomas (21 unilateral, 5 bilateral) treated by stereotactic radiosurgery using the first North American 201-source cobalt-60 gamma knife. Follow-up ranged from 6 to 19 months (median, 13 months). Serial postoperative imaging showed either a decrease in tumor size (11 patients) or growth arrest (15 patients). Loss of central contrast enhancement was a characteristic change (18 patients). Seven patients had good or serviceable hearing preoperatively. In all 7 the preoperative hearing status was retained immediately after radiosurgery. At follow-up, 3 had preserved hearing, 1 had reduced hearing, and 3 had lost all hearing in the treated ear. Hearing in 1 patient that was nonserviceable preoperatively later improved to a serviceable hearing level. Delayed facial paresis developed in 6 patients, and delayed trigeminal sensory loss developed in 7 patients, none of whom had significant deficits before radiosurgery. Both facial and trigeminal deficits tended to improve within 3 to 6 months of onset with excellent recovery anticipated. Lower cranial nerve dysfunction was not observed. All 26 patients remain at their preoperative employment or functional status. At present, stereotactic radiosurgery is an alternative treatment for acoustic neurinomas in patients who are elderly, have significant concomitant medical problems, have a tumor in their only hearing ear, have bilateral acoustic neurinomas, refuse microsurgical excision, or have recurrent tumor despite surgical resection. Although longer and more extensive follow-up is required, the control of tumor growth and the acceptable rate of complications in this early experience testifies to the future expanding role of this technique in the management of selected acoustic neurinomas

  7. Geometrically based optimization for extracranial radiosurgery

    International Nuclear Information System (INIS)

    Liu Ruiguo; Wagner, Thomas H; Buatti, John M; Modrick, Joseph; Dill, John; Meeks, Sanford L

    2004-01-01

    For static beam conformal intracranial radiosurgery, geometry of the beam arrangement dominates overall dose distribution. Maximizing beam separation in three dimensions decreases beam overlap, thus maximizing dose conformality and gradient outside of the target volume. Webb proposed arrangements of isotropically convergent beams that could be used as the starting point for a radiotherapy optimization process. We have developed an extracranial radiosurgery optimization method by extending Webb's isotropic beam arrangements to deliverable beam arrangements. This method uses an arrangement of N maximally separated converging vectors within the space available for beam delivery. Each bouquet of isotropic beam vectors is generated by a random sampling process that iteratively maximizes beam separation. Next, beam arrangement is optimized for critical structure avoidance while maintaining minimal overlap between beam entrance and exit pathways. This geometrically optimized beam set can then be used as a template for either conformal beam or intensity modulated extracranial radiosurgery. Preliminary results suggest that using this technique with conformal beam planning provides high plan conformality, a steep dose gradient outside of the tumour volume and acceptable critical structure avoidance in the majority of clinical cases

  8. Gamma knife radiosurgery for endocrine-inactive pituitary adenomas

    International Nuclear Information System (INIS)

    Liscak, R.; Vladyka, V.; Simonova, G.; Marek, J.; Vymazal, J.

    2007-01-01

    The goal of nonsecreting pituitary adenoma radiosurgery is to halt tumor growth and to maintain normal performance of the hypophysis and the functionally important structures around the sella. The effectiveness of gamma knife radiosurgery was evaluated. Over a period of 10 years (1993-2003), 140 patients with nonsecreting pituitary adenoma were treated by Leksell gamma knife at our Centre. Seventy-nine of them were followed up for longer than 3 years. Their age range was 24-73 years, with a median of 54 years. Eighty-five percent of them had previous open surgery. Fifteen patients had adenoma contact with the optic tract. Fourteen patients had a normally functioning hypophysis, 48 patients had complete panhypopituitarism, while the rest retained partial functions of the normal hypophysis. Adenoma volumes ranged between 0.1 and 31.3, the median being 3.45 ccm. The marginal dose ranged between 12 and -35 Gy, with a median of 20 Gy. The follow-up ranged from 36 to 122 months, with a median of 60 months. No adenoma growth was detected; 89 % of treated adenomas decreased in size, with a median volume reduction of 61 %. There was no perimeter vision impairment after radiosurgery, while 4 out of 52 patients with abnormal perimeter vision reported improvement. There was no impairment of oculomotor nerve function. Impairment of hypophysis function was observed in 2 patients. Radiosurgery has a reliable antiproliferative effect on nonsecreting pituitary adenomas. It is a safe treatment with a low risk of morbidity. Short contact between a nonsecreting pituitary adenoma and the optic pathway is not an absolute contraindication for Gamma knife radiosurgery. (author)

  9. A simulation and training environment for robotic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Schlaefer, Alexander [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany); Stanford University, Department of Radiation Oncology, Stanford, CA (United States); Gill, Jakub; Schweikard, Achim [University of Luebeck, Institute for Robotics and Cognitive Systems, Luebeck (Germany)

    2008-09-15

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  10. A simulation and training environment for robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, Alexander; Gill, Jakub; Schweikard, Achim

    2008-01-01

    To provide a software environment for simulation of robotic radiosurgery, particularly to study the effective robot workspace with respect to the treatment plan quality, and to illustrate the concepts of robotic radiosurgery. A simulation environment for a robotic radiosurgery system was developed using Java and Java3D. The kinematics and the beam characteristics were modeled and linked to a treatment planning module. Simulations of different robot workspace parameters for two example radiosurgical patient cases were performed using the novel software tool. The first case was an intracranial lesion near the left inner ear, the second case was a spinal lesion. The planning parameters for both cases were visualized with the novel simulation environment. An incremental extension of the robot workspace had limited effect for the intracranial case, where the original workspace already covered the left side of the patient. For the spinal case, a larger workspace resulted in a noticeable improvement in plan quality and a large portion of the beams being delivered from the extended workspace. The new software environment is useful to simulate and analyze parameters and configurations for robotic radiosurgery. An enlarged robot workspace may result in improved plan quality depending on the location of the target region. (orig.)

  11. Seizure control of Gamma Knife radiosurgery for non-hemorrhagic arteriovenous malformations

    International Nuclear Information System (INIS)

    Lim, Y.J.; Lee, C.Y.; Koh, J.S.; Kim, T.S.; Kim, G.K.; Rhee, B.A.

    2006-01-01

    Although radiosurgery has been found to be a safe and effective alternative treatment, seizure outcome of arteriovenous malformation (AVM) radiosurgery has not been documented in detail. We report the effect of Gamma Knife radiosurgery (GKRS) on seizures associated with AVMs and discuss the various factors that influence the prognosis. Between 1992 and 2001 246 patients were treated with GKRS for AVMs at Kyung-Hee medical center. Forty five (17.0 %) patients have non-hemorrhagic AVMs and presenting symptom was seizure. Two patients of all were excluded from this study due to loss of follow-up after radiosurgery. In this study retrospective analysis of clinical characteristics, radiological findings, radiosurgical seizure outcome were performed. There were 32 male and 11 female with age ranging from 10 to 74 years (mean 35 years). Type of seizure included: general tonic clonic (n = 28); focal motor or sensory (n = 7): partial complex (n = 8). The location of AVM was temporal (n = 18); frontal (n = 9): deep seated (n =7): parietal (n = 5); occipital (n = 4). Follow-up period was from 8 months to 12 years (mean 46 months). Mean volume was 6.2 cc (2.7-20), mean marginal and maximal dosage was 19.5 (17-26) and 36.6 Gy (13-50). During follow-up after radiosurgical treatment, 23 (53.5 %) of 43 patients were seizure-free. 10 (23.3 %) had significant improvement, were unchanged in 8 (18.6 %) and aggravated in 2 (4.6 %) patients. In 33 patients, follow-up angiography or MRI was performed. Complete obliteration was achieved in 16 (49.0 %) patients, partial obliteration in 13 (39.0 %). Four were unchanged (12.0 %). Of 33 patients with follow-up performed, 26 were followed for over 2 years. Eleven (84.6 %) of 13 patients with complete obliteration were seizure-free (p < 0.005). Four (36.3 %) of 13 with partial obliteration and unchanged remained seizure-free. Fifteen patients had experienced intractable seizure before radiosurgery. After radiosurgery, seizures disappeared in 8

  12. Design and study of parallel computing environment of Monte Carlo simulation for particle therapy planning using a public cloud-computing infrastructure

    International Nuclear Information System (INIS)

    Yokohama, Noriya

    2013-01-01

    This report was aimed at structuring the design of architectures and studying performance measurement of a parallel computing environment using a Monte Carlo simulation for particle therapy using a high performance computing (HPC) instance within a public cloud-computing infrastructure. Performance measurements showed an approximately 28 times faster speed than seen with single-thread architecture, combined with improved stability. A study of methods of optimizing the system operations also indicated lower cost. (author)

  13. Massively parallel multicanonical simulations

    Science.gov (United States)

    Gross, Jonathan; Zierenberg, Johannes; Weigel, Martin; Janke, Wolfhard

    2018-03-01

    Generalized-ensemble Monte Carlo simulations such as the multicanonical method and similar techniques are among the most efficient approaches for simulations of systems undergoing discontinuous phase transitions or with rugged free-energy landscapes. As Markov chain methods, they are inherently serial computationally. It was demonstrated recently, however, that a combination of independent simulations that communicate weight updates at variable intervals allows for the efficient utilization of parallel computational resources for multicanonical simulations. Implementing this approach for the many-thread architecture provided by current generations of graphics processing units (GPUs), we show how it can be efficiently employed with of the order of 104 parallel walkers and beyond, thus constituting a versatile tool for Monte Carlo simulations in the era of massively parallel computing. We provide the fully documented source code for the approach applied to the paradigmatic example of the two-dimensional Ising model as starting point and reference for practitioners in the field.

  14. Monte Carlo simulation with the Gate software using grid computing

    International Nuclear Information System (INIS)

    Reuillon, R.; Hill, D.R.C.; Gouinaud, C.; El Bitar, Z.; Breton, V.; Buvat, I.

    2009-03-01

    Monte Carlo simulations are widely used in emission tomography, for protocol optimization, design of processing or data analysis methods, tomographic reconstruction, or tomograph design optimization. Monte Carlo simulations needing many replicates to obtain good statistical results can be easily executed in parallel using the 'Multiple Replications In Parallel' approach. However, several precautions have to be taken in the generation of the parallel streams of pseudo-random numbers. In this paper, we present the distribution of Monte Carlo simulations performed with the GATE software using local clusters and grid computing. We obtained very convincing results with this large medical application, thanks to the EGEE Grid (Enabling Grid for E-science), achieving in one week computations that could have taken more than 3 years of processing on a single computer. This work has been achieved thanks to a generic object-oriented toolbox called DistMe which we designed to automate this kind of parallelization for Monte Carlo simulations. This toolbox, written in Java is freely available on SourceForge and helped to ensure a rigorous distribution of pseudo-random number streams. It is based on the use of a documented XML format for random numbers generators statuses. (authors)

  15. Scalable Domain Decomposed Monte Carlo Particle Transport

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, Matthew Joseph [Univ. of California, Davis, CA (United States)

    2013-12-05

    In this dissertation, we present the parallel algorithms necessary to run domain decomposed Monte Carlo particle transport on large numbers of processors (millions of processors). Previous algorithms were not scalable, and the parallel overhead became more computationally costly than the numerical simulation.

  16. The treatment for acoustic neuromas. Indication and results of gamma knife radiosurgery and surgery

    International Nuclear Information System (INIS)

    Iwai, Yoshiyasu; Yamanaka, Kazuhiro; Uyama, Taichi; Morikawa, Toshie; Honda, Yuji; Matsusaka, Yasuhiro; Komiyama, Masaki; Yasui, Toshihiro

    2004-01-01

    We evaluated the treatment results of acoustic neuromas in the era of radiosurgery. We treated acoustic neuromas using the following strategy. Small to medium size tumors (below 3 cm) were treated by gamma knife radiosurgery and large tumors (above 3 cm) were treated using a combination of surgery and radiosurgery. Using gamma knife radiosurgery we were able to achieve 96.4% of clinical tumor growth control with 0.7% incidence of trigeminal neuropathy (without new facial neuropathy). We used low dose radiosurgery (average tumor marginal dose 11.8 Gy) with a follow-up of an average of 54 months. For the 17 patients with large tumors treated by the combination of surgery and radiosurgery who could be followed up for over 24 months after radiosurgery, we were able to preserve normal facial function (House-Brackmann grade I-II) in 70.6% of the patients after subtotal removal. High clinical tumor growth control for residual tumor was achieved in 94.1% of subjects with an average of 40 months follow-up. By using this strategy, the treatment outcome for acoustic neuroma is improved from the standpoint of functional outcome and maintaining the patient's quality of life. (author)

  17. MO-A-BRD-08: Radiosurgery Beyond Cancer: Real-Time Target Localization and Treatment Planning for Cardiac Radiosurgery Under MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S [University of Luebeck, Luebeck, SH (Germany); University of Sydney, Camperdown (Australia); Blanck, O [CyberKnife Zentrum Norddeutschland, Guestrow, MV (Germany); Oborn, B [Illawarra Cancer Care Centre, Wollongong, NSW (Australia); Bode, F [Medical Clinic II, Section for Electrophysiology, UKSH, Luebeck, SH (Germany); Liney, G [Ingham Institute for Applied Medical Research, Liverpool, NSW (United Kingdom); Keall, P [University of Sydney, Camperdown (Australia)

    2014-06-15

    Purpose: Atrial fibrillation (AF) is the most common cardiac arrhythmia, affecting >2.5M Americans and >4.5M Europeans. AF is usually treated with minimally-invasive, time consuming catheter ablation techniques. Radiosurgery of the pulmonary veins (PV) has been proposed for AF treatment, however is challenging due to the complex respiratory and cardiac motion patterns. We hypothesize that an MRI-linac could solve the difficult real-time targeting and adaptation problem. In this study we quantified target motion ranges on cardiac MRI and analyzed the dosimetric benefits of margin reduction assuming real-time MRI tracking was applied. Methods: For the motion study, four human subjects underwent real-time cardiac MRI under free breathing. The target motion on coronal and axial cine planes was analyzed using a template matching algorithm. For the planning study, an ablation line at each PV antrum was defined as target on an AF patient scheduled for catheter ablation. Various safety margins ranging from 0mm (perfect tracking) to 8mm (untracked motion) were added to the target defining the PTV. 30Gy single fraction IMRT plans were then generated. Finally, the influence of a 1T magnetic field on treatment beam delivery was calculated using the Geant4 Monte Carlo algorithm to simulate the dosimetric impact of MRI guidance. Results: The motion study showed the mean respiratory motion of the target area on MRI was 8.4mm (SI), 1.7mm (AP) and 0.3mm (LR). Cardiac motion was small (<2mm). The planning study showed that with increasing safety margins to encompass untracked motion, dose tolerances for OARs such as the esophagus and airways were exceeded by >100%. The magnetic field had little impact on the dose distribution. Conclusion: Our results indicate that real-time MRI tracking of the PVs seems feasible. Accurate image guidance for high-dose AF radiosurgery is essential since safety margins covering untracked target motion will result in unacceptable treatment plans.

  18. Tumour response and morphological changes of acoustic neurinomas after radiosurgery

    International Nuclear Information System (INIS)

    Valentino, V.; Raimondi, A.J.

    1995-01-01

    Twenty-seven of the 1560 patients treated by radiosurgery during the period 1984-1993 had acoustic neurinomas. Four cases were excluded from this study because they had a follow-up of less than 2 years. There were 24 neurinomas treated in 23 patients as one patient had a bilateral tumour. Seven patients underwent radiosurgery for a recurrent tumour (already operated on once or twice), while it was the first treatment for 16 patients. The tumour volume ranged from 1.99 cm 3 to 18.30 cm 3 , and the patient follow-up was from 2 to 8 years. To determine the target on CT/NMR for linear accelerator stereotactic irradiation, the Greitz-Bergstroem non-invasive head fixation device was used. It was again adopted for subsequent serial imaging, and for repeat radiosurgery when necessary. The total peripheral tumour dose ranged from 12 to 45 Gy. In 9 patients there was a reduction in tumour volume varying from 39 to 100% , while 14 of the neurinomas appeared stable after an average follow-up of 3 years. In one patient there was an increase in size of the tumour. Variable morphological changes were present in 66% of the neurinomas treated. Radiosurgery is indicated as an alternative to microsurgery for inoperab1e patients and for those who refuse surgery, for recurrent tumours, and as a post-operative complementary treatment for partially removed tumours. A gradual approach to radiosurgery, depending on tumour response, allows a greater efficacy with minimal risk. In the present series no complications were observed. Hearing was preserved at almost the same level as that prior to radiosurgery in all patients. (author)

  19. Dose conformity of gamma knife radiosurgery and risk factors for complications

    International Nuclear Information System (INIS)

    Nakamura, Jean L.; Verhey, Lynn J.; Smith, Vernon; Petti, Paula L.; Lamborn, Kathleen R.; Larson, David A.; Wara, William M.; McDermott, Michael W.; Sneed, Penny K.

    2001-01-01

    Purpose: To quantitatively evaluate dose conformity achieved using Gamma Knife radiosurgery, compare results with those reported in the literature, and evaluate risk factors for complications. Methods and Materials: All lesions treated at our institution with Gamma Knife radiosurgery from May 1993 (when volume criteria were routinely recorded) through December 1998 were reviewed. Lesions were excluded from analysis for reasons listed below. Conformity index (the ratio of prescription volume to target volume) was calculated for all evaluable lesions and for lesions comparable to those reported in the literature on conformity of linac radiosurgery. Univariate Cox regression models were used to test for associations between treatment parameters and toxicity. Results: Of 1612 targets treated in 874 patients, 274 were excluded, most commonly for unavailability of individual prescription volume data because two or more lesions were included within the same dose matrix (176 lesions), intentional partial coverage for staged treatment of large arteriovenous malformations (AVMs) (33 lesions), and missing target volume data (26 lesions). The median conformity indices were 1.67 for all 1338 evaluable lesions and 1.40-1.43 for lesions comparable to two linac radiosurgery series that reported conformity indices of 1.8 and 2.7, respectively. Among all 651 patients evaluable for complications, there were one Grade 5, eight Grade 4, and 27 Grade 3 complications. Increased risk of toxicity was associated with larger target volume, maximum lesion diameter, prescription volume, or volume of nontarget tissue within the prescription volume. Conclusions: Gamma Knife radiosurgery achieves much more conformal dose distributions than those reported for conventional linac radiosurgery and somewhat more conformal dose distributions than sophisticated linac radiosurgery techniques. Larger target, nontarget, or prescription volumes are associated with increased risk of toxicity

  20. Stereotactic Radiosurgery versus Natural History in Patients with Growing Vestibular Schwannomas.

    Science.gov (United States)

    Tu, Albert; Gooderham, Peter; Mick, Paul; Westerberg, Brian; Toyota, Brian; Akagami, Ryojo

    2015-08-01

    Objective To describe our experience with stereotactic radiosurgery and its efficacy on growing tumors, and then to compare this result with the natural history of a similar cohort of non-radiation-treated lesions. Study Design A retrospective chart review and cohort comparison. Methods The long-term control rates of patients having undergone radiosurgery were collected and calculated, and this population was then compared with a group of untreated patients from the same period of time with growing lesions. Results A total of 61 patients with growing vestibular schwannomas treated with radiosurgery were included. After a mean of 160 months, we observed a control rate of 85.2%. When compared with a group of 36 patients with growing tumors who were yet to receive treatment (previously published), we found a corrected control rate or relative risk reduction of only 76.8%. Conclusion Radiosurgery for growing vestibular schwannomas is less effective than previously reported in unselected series. Although radiosurgery still has a role in managing this disease, consideration should be given to the actual efficacy that may be calculated when the natural history is known. We hope other centers will similarly report their experience on this cohort of patients.

  1. SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Han, B; Xing, L; Wang, L

    2016-01-01

    Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient

  2. SU-E-T-467: Implementation of Monte Carlo Dose Calculation for a Multileaf Collimator Equipped Robotic Radiotherapy System

    Energy Technology Data Exchange (ETDEWEB)

    Li, JS; Fan, J; Ma, C-M [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To improve the treatment efficiency and capabilities for full-body treatment, a robotic radiosurgery system has equipped with a multileaf collimator (MLC) to extend its accuracy and precision to radiation therapy. To model the MLC and include it in the Monte Carlo patient dose calculation is the goal of this work. Methods: The radiation source and the MLC were carefully modeled to consider the effects of the source size, collimator scattering, leaf transmission and leaf end shape. A source model was built based on the output factors, percentage depth dose curves and lateral dose profiles measured in a water phantom. MLC leaf shape, leaf end design and leaf tilt for minimizing the interleaf leakage and their effects on beam fluence and energy spectrum were all considered in the calculation. Transmission/leakage was added to the fluence based on the transmission factors of the leaf and the leaf end. The transmitted photon energy was tuned to consider the beam hardening effects. The calculated results with the Monte Carlo implementation was compared with measurements in homogeneous water phantom and inhomogeneous phantoms with slab lung or bone material for 4 square fields and 9 irregularly shaped fields. Results: The calculated output factors are compared with the measured ones and the difference is within 1% for different field sizes. The calculated dose distributions in the phantoms show good agreement with measurements using diode detector and films. The dose difference is within 2% inside the field and the distance to agreement is within 2mm in the penumbra region. The gamma passing rate is more than 95% with 2%/2mm criteria for all the test cases. Conclusion: Implementation of Monte Carlo dose calculation for a MLC equipped robotic radiosurgery system is completed successfully. The accuracy of Monte Carlo dose calculation with MLC is clinically acceptable. This work was supported by Accuray Inc.

  3. SU-E-T-467: Implementation of Monte Carlo Dose Calculation for a Multileaf Collimator Equipped Robotic Radiotherapy System

    International Nuclear Information System (INIS)

    Li, JS; Fan, J; Ma, C-M

    2015-01-01

    Purpose: To improve the treatment efficiency and capabilities for full-body treatment, a robotic radiosurgery system has equipped with a multileaf collimator (MLC) to extend its accuracy and precision to radiation therapy. To model the MLC and include it in the Monte Carlo patient dose calculation is the goal of this work. Methods: The radiation source and the MLC were carefully modeled to consider the effects of the source size, collimator scattering, leaf transmission and leaf end shape. A source model was built based on the output factors, percentage depth dose curves and lateral dose profiles measured in a water phantom. MLC leaf shape, leaf end design and leaf tilt for minimizing the interleaf leakage and their effects on beam fluence and energy spectrum were all considered in the calculation. Transmission/leakage was added to the fluence based on the transmission factors of the leaf and the leaf end. The transmitted photon energy was tuned to consider the beam hardening effects. The calculated results with the Monte Carlo implementation was compared with measurements in homogeneous water phantom and inhomogeneous phantoms with slab lung or bone material for 4 square fields and 9 irregularly shaped fields. Results: The calculated output factors are compared with the measured ones and the difference is within 1% for different field sizes. The calculated dose distributions in the phantoms show good agreement with measurements using diode detector and films. The dose difference is within 2% inside the field and the distance to agreement is within 2mm in the penumbra region. The gamma passing rate is more than 95% with 2%/2mm criteria for all the test cases. Conclusion: Implementation of Monte Carlo dose calculation for a MLC equipped robotic radiosurgery system is completed successfully. The accuracy of Monte Carlo dose calculation with MLC is clinically acceptable. This work was supported by Accuray Inc

  4. Gamma-knife radiosurgery for metastatic brain tumors from primary lung cancer

    International Nuclear Information System (INIS)

    Uchiyama, Bine; Satoh, Ken; Saijo, Yasuo

    1998-01-01

    Forty patients with metastatic brain tumors from primary lung cancer underwent radiosurgery (γ-knife). We retrospectively compared their prior treatment history, number of metastatic foci, and performance status, to evaluate the effects of, and indications for, γ-knife therapy. After both the primary and the metastatic tumors were controlled, performance status could be used as an index in the choice of γ-knife therapy. Our results demonstrate that repeated γ-knife radiosurgeries prolonged survival time. Gamma-knife radiosurgery improves quality of life and prognosis of patients with metastatic brain tumors. (author)

  5. Radiosurgery of craniopharyngiomas. Results of long-term follow-up

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Hasegawa, Toshinori; Yoshimoto, Masayuki; Koike, Johzi; Kobayashi, Tatsuya

    2007-01-01

    Long-term follow-up results of craniopharyngiomas after radiosurgery are reported. Among 125 cases of craniopharyngioma, long-term follow-up more than 6 months is obtained in 108 cases. Majority of the cases have had surgical excision before radiosurgery. The tumors, 19 mm in mean diameter were treated with the mean maximum dose of 22.1 Gy and with the marginal dose of 11.6 Gy. The final radiological outcomes during 63 months of mean follow-up showed 9 complete responses (CRs), 61 partial responses (PRs), 1 minor response (MR), 19 no changes (NCs) and 18 PGs, indicating the response rate of 65% and the control rate of 83% respectively. Neurological and endocrinological signs were improved in 18%, unchanged in 53% and worsened in 15% of cases, meanwhile 8% of the patients were dead. Small and solid tumors were the best indication for radiosurgery due to excellent tumor control as well as no adverse effects. They may have a good chance for complete remission. In conclusion a sufficient tumor resection with microsurgery is required and subsequent radiosurgery is most adequate for treating craniopharyngiomas. (author)

  6. Compensating for Quasi-periodic Motion in Robotic Radiosurgery

    CERN Document Server

    Ernst, Floris

    2012-01-01

    Compensating for Quasi-periodic Motion in Robotic Radiosurgery outlines the techniques needed to accurately track and compensate for respiratory and pulsatory motion during robotic radiosurgery. The algorithms presented within the book aid in the treatment of tumors that move during respiration. In Chapters 1 and 2,  the book introduces the concept of stereotactic body radiation therapy, motion compensation strategies and the clinical state-of-the-art. In Chapters 3 through 5, the author describes and evaluates new methods for motion prediction, for correlating external motion to internal organ motion, and for the evaluation of these algorithms’ output based on an unprecedented amount of real clinical data. Finally, Chapter 6 provides a brief introduction into currently investigated, open questions and further fields of research. Compensating for Quasi-periodic Motion in Robotic Radiosurgery targets researchers working in the related fields of surgical oncology, artificial intelligence, robotics and more. ...

  7. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Lamba, Michael; Breneman, John C.; Warnick, Ronald E.

    2009-01-01

    Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 ± 0.5 mm) and image-guided (0.6 ± 0.2 mm) techniques. The in vivo differences in alignment were 0.9 ± 0.5 mm (anteroposterior), -0.2 ± 0.4 mm (superoinferior), and 0.3 ± 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 ± 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

  8. Image-guided linear accelerator-based spinal radiosurgery for hemangioblastoma.

    Science.gov (United States)

    Selch, Michael T; Tenn, Steve; Agazaryan, Nzhde; Lee, Steve P; Gorgulho, Alessandra; De Salles, Antonio A F

    2012-01-01

    To retrospectively review the efficacy and safety of image-guided linear accelerator-based radiosurgery for spinal hemangioblastomas. Between August 2004 and September 2010, nine patients with 20 hemangioblastomas underwent spinal radiosurgery. Five patients had von Hipple-Lindau disease. Four patients had multiple tumors. Ten tumors were located in the thoracic spine, eight in the cervical spine, and two in the lumbar spine. Tumor volume varied from 0.08 to 14.4 cc (median 0.72 cc). Maximum tumor dimension varied from 2.5 to 24 mm (median 10.5 mm). Radiosurgery was performed with a dedicated 6 MV linear accelerator equipped with a micro-multileaf collimator. Median peripheral tumor dose and prescription isodose were 12 Gy and 90%, respectively. Image guidance was performed by optical tracking of infrared reflectors, fusion of oblique radiographs with dynamically reconstructed digital radiographs, and automatic patient positioning. Follow-up varied from 14 to 86 months (median 51 months). Kaplan-Meier estimated 4-year overall and solid tumor local control rates were 90% and 95%, respectively. One tumor progressed 12 months after treatment and a new cyst developed 10 months after treatment in another tumor. There has been no clinical or imaging evidence for spinal cord injury. Results of this limited experience indicate linear accelerator-based radiosurgery is safe and effective for spinal cord hemangioblastomas. Longer follow-up is necessary to confirm the durability of tumor control, but these initial results imply linear accelerator-based radiosurgery may represent a therapeutic alternative to surgery for selected patients with spinal hemangioblastomas.

  9. Neuropsychologic changes in patients with arterio-venous malformation (AVM) after radiosurgery

    International Nuclear Information System (INIS)

    Steinvorth, S.; Wenz, F.; Wildermuth, S.; Fuss, M.; Debus, J.; Lohr, F.; Wannenmacher, M.

    1997-01-01

    the follow-up period included reassessment of attention and memory using parallel versions of the tests. Patients were classified as having neuropsychological deficits, when their test results were one standard deviation (z ≤ -1.0) below the mean (z = 0) of the normal distribution. Results: The pretherapeutic evaluation revealed already significant deviations from the normal population in this patient group. Twenty-four percent of the patients had deficits in general intelligence (18 - 38% in the different subtests), in attention (25 - 31%) and memory (42 - 61%). The table shows the percentage of patients with deficits in attention and memory during the acute, subacute and chronic phase after radiosurgery. The numbers give the range for 4 subtest of attention and memory, respectively: Conclusion: The acute tolerance of radiosurgery seems to be very good in these patients showing no relevant increase in number of patients with neuropsychological deficits. Although the long term follow-up needs to be further increased, our data indicate a tendency of slight improvement in the overall performance of AVM patients in the chronic phase after radiosurgey. This would mean that the benefit for the patient by irradiation of the AVM outweights the irradiation induced normal tissue effects

  10. Five Fraction Image-Guided Radiosurgery for Primary and Recurrent Meningiomas

    Directory of Open Access Journals (Sweden)

    Eric Karl Oermann

    2013-08-01

    Full Text Available Purpose: Benign tumors that arise from the meninges can be difficult to treat due to their potentially large size and proximity to critical structures such as cranial nerves and sinuses. Single fraction radiosurgery may increase the risk of symptomatic peritumoral edema. In this study, we report our results on the efficacy and safety of five fraction image-guided radiosurgery for benign meningiomas. Materials/Methods: Clinical and radiographic data from 38 patients treated with five fraction radiosurgery were reviewed retrospectively. Mean tumor volume was 3.83mm3 (range, 1.08-20.79 mm3. Radiation was delivered using the CyberKnife, a frameless robotic image-guided radiosurgery system with a median total dose of 25 Gy (range, 25 Gy-35 Gy. Results: The median follow-up was 20 months. Acute toxicity was minimal with eight patients (21% requiring a short course of steroids for headache at the end of treatment. Pre-treatment neurological symptoms were present in 24 patients (63.2%. Post treatment, neurological symptoms resolved completely in 14 patients (58.3%, and were persistent in eight patients (33.3%. There were no local failures, 24 tumors remained stable (64% and 14 regressed (36%. Pre-treatment peritumoral edema was observed in five patients (13.2%. Post-treatment asymptomatic peritumoral edema developed in five additional patients (13.2%. On multivariate analysis, pre-treatment peritumoral edema and location adjacent to a large vein were significant risk factors for radiographic post-treatment edema (p = 0.001 and p = 0.026 respectively. Conclusions: These results suggest that five fraction image-guided radiosurgery is well tolerated with a response rate for neurologic symptoms that is similar to other standard treatment options. Rates of peritumoral edema and new cranial nerve deficits following five fraction radiosurgery were low. Longer follow-up is required to validate the safety and long-term effectiveness of this treatment approach.

  11. SU-F-J-160: Clinical Evaluation of Targeting Accuracy in Radiosurgery Using Tractography

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R; Han, J; Kim, C; Oh, C [Seoul National University Bundang Hospital, Seongnamsi, GyeonggiDo (Korea, Republic of); Suh, T [The catholic university of Korea, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 males, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve. Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated. Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement. Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment

  12. Contemporary treatment with radiosurgery for spine metastasis and spinal cord compression in 2015

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Sam Uel; Yoon, Han Hah; Stessin, Alexander; Gutman, Fred; Rosiello, Arthur; Davis, Raphael [Stony Brook University, Stony Brook (United States)

    2015-03-15

    With the progress of image-guided localization, body immobilization system, and computerized delivery of intensity-modulated radiation delivery, it became possible to perform spine radiosurgery. The next question is how to translate the high technology treatment to the clinical application. Clinical trials have been performed to demonstrate the feasibility of spine radiosurgery and efficacy of the treatment in the setting of spine metastasis, leading to the randomized trials by a cooperative group. Radiosurgery has also demonstrated its efficacy to decompress the spinal cord compression in selected group of patients. The experience indicates that spine radiosurgery has a potential to change the clinical practice in the management of spine metastasis and spinal cord compression.

  13. Monte Carlo simulation of the Leksell Gamma Knife: I. Source modelling and calculations in homogeneous media

    Energy Technology Data Exchange (ETDEWEB)

    Moskvin, Vadim [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)]. E-mail: vmoskvin@iupui.edu; DesRosiers, Colleen; Papiez, Lech; Timmerman, Robert; Randall, Marcus; DesRosiers, Paul [Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN (United States)

    2002-06-21

    The Monte Carlo code PENELOPE has been used to simulate photon flux from the Leksell Gamma Knife, a precision method for treating intracranial lesions. Radiation from a single {sup 60}Co assembly traversing the collimator system was simulated, and phase space distributions at the output surface of the helmet for photons and electrons were calculated. The characteristics describing the emitted final beam were used to build a two-stage Monte Carlo simulation of irradiation of a target. A dose field inside a standard spherical polystyrene phantom, usually used for Gamma Knife dosimetry, has been computed and compared with experimental results, with calculations performed by other authors with the use of the EGS4 Monte Carlo code, and data provided by the treatment planning system Gamma Plan. Good agreement was found between these data and results of simulations in homogeneous media. Owing to this established accuracy, PENELOPE is suitable for simulating problems relevant to stereotactic radiosurgery. (author)

  14. The treatment for asymptomatic meningiomas in the era of radiosurgery

    International Nuclear Information System (INIS)

    Iwai, Yoshiyasu; Yamanaka, Kazuhiro; Morikawa, Toshie; Ishiguro, Tomoya; Honda, Yuji; Matsusaka, Yasuhiro; Komiyama, Masaki; Yasui, Toshihiro

    2003-01-01

    We evaluated the treatment results in asymptomatic meningiomas in the era of radiosurgery. We encountered 56 patients with asymptomatic meningiomas from January, 1994 to December, 2001. There were 16 male patients and 40 female patients. The most common location was the cerebral convexity. We performed gamma knife radiosurgery for three patients after diagnosis of cavernous sinus meningiomas. The other patients were followed-up after diagnosis for a mean follow-up period of 30.8 months (5 months to 8 years). Tumor growth was verified in 25 patients (43%) and two patients (3.7%) suffered neurological deficits. Among the tumor growth patients, operative resection was performed in six patients (11%) and gamma knife radiosurgery was performed in four patients (7.5%). The other patients were placed under observation. We decided the treatment strategy paying attention to the tumor location, tumor growth speed, tumor size and operative difficulty. The tumor growth rate was 0.1 cm/year among the patients with tumor growth. It was 0.72 cm/year (0.02 to 1.54 cm/year) in the operative group, 0.3 cm/year (0.04 to 0.76 cm/year) in the gamma knife radiosurgery group and 0.08 cm/year (0.01 to 0.76 cm/year) in the observed group. One patient suffered procedure-related deterioration of paresis after operation. The treatment of asymptomatic meningiomas must be decided depending on their natural history and locations. We recommend early radiosurgery for cavernous sinus meningiomas. (author)

  15. Failure modes and effects analysis (FMEA) for Gamma Knife radiosurgery.

    Science.gov (United States)

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Flickinger, John; Arai, Yoshio; Vacsulka, Jonet; Feng, Wenzheng; Monaco, Edward; Niranjan, Ajay; Lunsford, L Dade; Huq, M Saiful

    2017-11-01

    Gamma Knife radiosurgery is a highly precise and accurate treatment technique for treating brain diseases with low risk of serious error that nevertheless could potentially be reduced. We applied the AAPM Task Group 100 recommended failure modes and effects analysis (FMEA) tool to develop a risk-based quality management program for Gamma Knife radiosurgery. A team consisting of medical physicists, radiation oncologists, neurosurgeons, radiation safety officers, nurses, operating room technologists, and schedulers at our institution and an external physicist expert on Gamma Knife was formed for the FMEA study. A process tree and a failure mode table were created for the Gamma Knife radiosurgery procedures using the Leksell Gamma Knife Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection for failure mode (D) were assigned to each failure mode by 8 professionals on a scale from 1 to 10. An overall risk priority number (RPN) for each failure mode was then calculated from the averaged O, S, and D scores. The coefficient of variation for each O, S, or D score was also calculated. The failure modes identified were prioritized in terms of both the RPN scores and the severity scores. The established process tree for Gamma Knife radiosurgery consists of 10 subprocesses and 53 steps, including a subprocess for frame placement and 11 steps that are directly related to the frame-based nature of the Gamma Knife radiosurgery. Out of the 86 failure modes identified, 40 Gamma Knife specific failure modes were caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the Gamma Knife helmets and plugs, the skull definition tools as well as other features of the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all external beam radiation therapy

  16. A new treatment method for brain diseases. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Shirato, Hiroki

    1994-01-01

    This paper deals with stereotactic radiosurgery, a novel medical treatment technique for brain diseases. It is the most sophisticated modality that allows the functional preservation. Recently, CT scan and MRI scan have dramatically changed the diagnostic accuracy of tumor localization in the brain. A device named stereotactic head fixation system makes it possible to localize deep-seated brain diseases with an accuracy of 1-1.5 mm. Using multiple convergent narrow beams of high-energy X-ray, a stereotactic head frame, and a three dimensional computer graphics of CT images, patients with deep-seated nidus can be treated without any complications. Normal tissues would not receive large doses but the center of the nidus is irradiated heavily because of the convergence of X-ray beams. Thus stereotactic radiosurgery is more accurate, effective, and less toxic than conventional radiotherapy and is safer and more effective than surgery for many brain diseases. Small arteriovenous malformation in the brain, which is a fetal disease, and small acoustic neurinomas, in which surgery often causes facial nerve palsy and hearing loss, are presented as good candidates for radiosurgery. For metastatic brain tumors, stereotactic radiosurgery makes such patients free from neurological symptoms, such as difficulty in walking and speaking, in a few days. (N.K.)

  17. Mean field simulation for Monte Carlo integration

    CERN Document Server

    Del Moral, Pierre

    2013-01-01

    In the last three decades, there has been a dramatic increase in the use of interacting particle methods as a powerful tool in real-world applications of Monte Carlo simulation in computational physics, population biology, computer sciences, and statistical machine learning. Ideally suited to parallel and distributed computation, these advanced particle algorithms include nonlinear interacting jump diffusions; quantum, diffusion, and resampled Monte Carlo methods; Feynman-Kac particle models; genetic and evolutionary algorithms; sequential Monte Carlo methods; adaptive and interacting Marko

  18. Poster - Thur Eve - 50: Planning and delivery accuracy of stereotactic radiosurgery with Tomotherapy as compared to linear-accelerator and robotic based radiosurgery.

    Science.gov (United States)

    Thakur, V; Soisson, E; Ruo, R; Doucet, R; Parker, W; Seuntjens, J

    2012-07-01

    This study includes planning and delivery comparison of three stereotactic radiosurgery techniques : Helical Tomotherapy (HT), circular collimator-based Linear-accelerator and robotic-radiosurgery. Plans were generated for two spherical targets of diameter 6 mm and 10 mm contoured at the center of a Lucite phantom, using similar planning constrains. Planning comparison showed that average conformality (0-1best) for Linear-accelerator, robotic-radiosurgery and HT was 1.43, 1.24, and 1.77 and gradient index (less is better) was 2.72, 4.50 and 13.56 respectively. For delivery comparison, plans were delivered to radiochromic film and measured dose was compared with the planned dose. For Linear-accelerator and robotic-radiosurgery more than 99% pixels-passing a gamma criteria of 3% dose difference and 1 mm distance to agreement where as for HT this value was as low as 40% for off-axis targets. Further investigation of the delivery accuracy as a function of the location of the target with in the bore was initiated using small volume A1SL (0.057 cm 3 ) and MicroLion liquid ion chamber (0.0017 cm 3 ). Point dose measurements for targets located at the center and 10 cm away from the center of the bore showed that delivered dose varied by more than 15% for targets placed away from the center of the bore as opposed to at the center. In conclusion, Linear-accelerator and the robotic-radiosurgery techniques showed preferable gradient and conformality. For HT, point dose measurements were significantly lower than predicted by the TPS when the target was positioned away from the isocenter, while they were found to be higher at isocenter. © 2012 American Association of Physicists in Medicine.

  19. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    International Nuclear Information System (INIS)

    Galván de la Cruz, Olga Olinca; Lárraga-Gutiérrez, José Manuel; Moreno-Jiménez, Sergio; García-Garduño, Olivia Amanda; Celis, Miguel Angel

    2013-01-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs

  20. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Galván de la Cruz, Olga Olinca [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jlarraga@innn.edu.mx [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Moreno-Jiménez, Sergio [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); García-Garduño, Olivia Amanda [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Celis, Miguel Angel [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico)

    2013-07-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.

  1. IRLED-based patient localization for linac radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Bova, Francis J.; Friedman, William A.; Buatti, John M.; Moore, Russell D.; Mendenhall, William M.

    1998-01-01

    Purpose: Currently, precise stereotactic radiosurgery delivery is possible with the Gamma Knife or floor-stand linear accelerator (linac) systems. Couch-mounted linac radiosurgery systems, while less expensive and more flexible than other radiosurgery delivery systems, have not demonstrated a comparable level of precision. This article reports on the development and testing of an optically guided positioning system designed to improve the precision of patient localization in couch-mounted linac radiosurgery systems. Methods and Materials: The optically guided positioning system relies on detection of infrared light-emitting diodes (IRLEDs) attached to a standard target positioner. The IRLEDs are monitored by a commercially available camera system that is interfaced to a personal computer. An IRLED reference is established at the center of stereotactic space, and the computer reports the current position of the IRLEDs relative to this reference position. Using this readout from the computer, the correct stereotactic coordinate can be set directly. Results: Bench testing was performed to compare the accuracy of the optically guided system with that of a floor-stand system, that can be considered an absolute reference. This testing showed that coordinate localization using the IRLED system to track translations agreed with the absolute to within 0.1 ± 0.1 mm. As rotations for noncoplanar couch angles were included, the inaccuracy was increased to 0.2 ± 0.1 mm. Conclusions: IRLED technology improves the accuracy of patient localization relative to the linac isocenter in comparison with conventional couch-mounted systems. Further, the patient's position can be monitored in real time as the couch is rotated for all treatment angles. Thus, any errors introduced by couch inaccuracies can be detected and corrected

  2. Gamma knife radiosurgery for cerebellopontine angle epidermoid tumors.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2017-01-01

    Intracranial epidermoid tumors are commonly found in the cerebellopontine angle where they usually present with either trigeminal neuralgia or hemifacial spasm. Radiosurgery for these tumors has rarely been reported. The purpose of this study is to assess the safety and clinical outcome of the treatment of cerebellopontine epidermoid tumors with gamma knife radiosurgery. This is a retrospective study involving 12 patients harboring cerebellopontine angle epidermoid tumors who underwent 15 sessions of gamma knife radiosurgery. Trigeminal pain was present in 8 patients and hemifacial spasm in 3 patients. All cases with trigeminal pain were receiving medication and still uncontrolled. One patient with hemifacial spasm was medically controlled before gamma knife and the other two were not. Two patients had undergone surgical resection prior to gamma knife treatment. The median prescription dose was 11 Gy (10-11 Gy). The tumor volumes ranged from 3.7 to 23.9 cc (median 10.5 cc). The median radiological follow up was 2 years (1-5 years). All tumors were controlled and one tumor shrank. The median clinical follow-up was 5 years. The trigeminal pain improved or disappeared in 5 patients, and of these, 4 cases stopped their medication and one decreased it. The hemifacial spasm resolved in 2 patients who were able to stop their medication. Facial palsy developed in 1 patient and improved with conservative treatment. Transient diplopia was also reported in 2 cases. Gamma knife radiosurgery provides good clinical control for cerebellopontine angle epidermoid tumors.

  3. Outcome After Pituitary Radiosurgery for Thalamic Pain Syndrome

    International Nuclear Information System (INIS)

    Hayashi, Motohiro; Chernov, Mikhail F.; Taira, Takaomi; Ochiai, Taku; Nakaya, Kotaro; Tamura, Noriko; Goto, Shinichi; Yomo, Shoji; Kouyama, Nobuo; Katayama, Yoko; Kawakami, Yoriko; Izawa, Masahiro; Muragaki, Yoshihiro

    2007-01-01

    Purpose: To evaluate outcomes after pituitary radiosurgery in patients with post-stroke thalamic pain syndrome. Methods and Materials: From 2002 to 2006, 24 patients with thalamic pain syndrome underwent pituitary radiosurgery at Tokyo Women's Medical University and were followed at least 12 months thereafter. The radiosurgical target was defined as the pituitary gland and its connection with the pituitary stalk. The maximum dose varied from 140 to 180 Gy. Mean follow-up after treatment was 35 months (range, 12-48 months). Results: Initial pain reduction, usually within 48 h after radiosurgery, was marked in 17 patients (71%). However, in the majority of cases the pain recurred within 6 months after treatment, and at the time of the last follow-up examination durable pain control was marked in only 5 patients (21%). Ten patients (42%) had treatment-associated side effects. Anterior pituitary abnormalities were marked in 8 cases and required hormonal replacement therapy in 3; transient diabetes insipidus was observed in 2 cases, transient hyponatremia in 1, and clinical deterioration due to increase of the numbness severity despite significant reduction of pain was seen once. Conclusions: Pituitary radiosurgery for thalamic pain results in a high rate of initial efficacy and is accompanied by acceptable morbidity. It can be used as a primary minimally invasive management option for patients with post-stroke thalamic pain resistant to medical therapy. However, in the majority of cases pain recurrence occurs within 1 year after treatment

  4. Leksell Gamma Knife radiosurgery of the jugulotympanic glomus tumor: long-term results.

    Science.gov (United States)

    Liscak, Roman; Urgosik, Dusan; Chytka, Tomas; Simonova, Gabriela; Novotny, Josef; Vymazal, Josef; Guseynova, Khumar; Vladyka, Vilibald

    2014-12-01

    Glomus tumors usually display indolent behavior, and the effectiveness of radiation in stopping their growth can be assessed after long-term follow-up. Currently only midterm results of radiosurgery are available, so the authors included patients treated by Gamma Knife at least 10 years ago in this study to obtain a perspective of long-term results. During the period from 1992 to 2003, the Gamma Knife was used to treat 46 patients with glomus tumors. The age of the patients ranged from 21 to 79 years (median 56 years). Gamma Knife radiosurgery was the primary treatment in 17 patients (37%). Open surgery preceded radiosurgery in 46% of cases, embolization in 17%, and fractionated radiotherapy in 4%. The volume of the tumor ranged from 0.2 to 24.3 cm(3) (median 3.6 cm(3)). The minimal dose to the tumor margin ranged between 10 and 30 Gy (median 20 Gy). One patient was lost for follow-up after radiosurgery. Clinical follow-up was available in 45 patients and 44 patients were followed with MRI in a follow-up period that ranged from 12 to 217 months (median 118 months). Neurological deficits improved in 19 (42%) of 45 patients and deteriorated in 2 patients (4%). Tumor size decreased in 34 (77%) of 44 patients with imaging follow-up, while an increase in volume was observed in 1 patient (2%) 182 months after radiosurgery and Gamma Knife treatment was repeated. One patient underwent another Gamma Knife treatment for secondary induced meningioma close to the glomus tumor 98 months after initial radiosurgical treatment. Seven patients died 22-96 months after radiosurgery (median 48 months), all for unrelated reasons. Radiosurgery has proved to be a safe treatment with a low morbidity rate and a reliable long-term antiproliferative effect.

  5. Gamma knife radiosurgery of radiation-induced intracranial tumors: Local control, outcomes, and complications

    International Nuclear Information System (INIS)

    Jensen, Ashley W.; Brown, Paul D.; Pollock, Bruce E.; Stafford, Scott L.; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.; Gorman, Deborah A.; Schomberg, Paula J.

    2005-01-01

    Purpose: To determine local control (LC) and complication rates for patients who underwent radiosurgery for radiation-induced intracranial tumors. Methods and Materials: Review of a prospectively maintained database (2,714 patients) identified 16 patients (20 tumors) with radiation-induced tumors treated with radiosurgery between 1990 and 2004. Tumor types included typical meningioma (n = 17), atypical meningioma (n = 2), and schwannoma (n 1). Median patient age at radiosurgery was 47.5 years (range, 27-70 years). The median tumor margin dose was 16 Gy (range, 12-20 Gy). Median follow-up was 40.2 months (range, 10.8-146.2 months). Time-to-event outcomes were calculated with Kaplan-Meier estimates. Results: Three-year and 5-year LC rates were 100%. Three-year and 5-year overall survival rates were 92% and 80%, respectively. Cause-specific survival rates at 3 and 5 years were 100%. Three patients died: 1 had in-field progression 65.1 months after radiosurgery and later died of the tumor, 1 died of progression of a preexisting brain malignancy, and 1 died of an unrelated cause. One patient had increased seizure activity that correlated with development of edema seen on neuroimaging. Conclusions: LC, survival, and complication rates in our series are comparable to those in previous reports of radiosurgery for intracranial meningiomas. Also, LC rates with radiosurgery are at least comparable to those of surgical series for radiation-induced meningiomas. Radiosurgery is a safe and effective treatment option for radiation-induced intracranial tumors, most of which are typical meningiomas

  6. Peritumoral hemorrhage after radiosurgery for metastatic brain tumor; A case report

    Energy Technology Data Exchange (ETDEWEB)

    Motozaki, Takahiko (Nishinomiya City General Hospital, Hyogo (Japan)); Ban, Sadahiko; Yamamoto, Toyoshiro; Hamasaki, Masatake

    1994-08-01

    An unusual case of peritumoral hemorrhage after radiosurgery for the treatment of metastatic brain tumor is reported. This 64-year-old woman had a history of breast cancer and underwent right mastectomy in 1989. She remained well until January 1993, when she started to have headache, nausea and speech disturbance, and was hospitalized on February 25, 1993. Neurological examination disclosed right hemiparesis and bilateral papilledema. CT scan and MR imaging showed a solitary round mass lesion in the left basal ganglia region. It was a well-demarcated, highly enhanced mass, 37 mm in diameter. Cerebral angiography confirmed a highly vascular mass lesion in the same location. She was treated with radiosurgery on March 8 (maximum dose was 20 Gy in the center and 10 Gy in the peripheral part of the tumor). After radiosurgery, she had an uneventful course and clinical and radiosurgical improvement could be detected. Her neurological symptoms and signs gradually improved and reduction of the tumor size and perifocal edema could be seen one month after radiosurgery. However, 6 weeks after radiosurgery, she suddenly developed semicoma and right hemiplegia. CT scan disclosed a massive peritumoral hemorrhage. Then, emergency craniotomy, evacuation of the hematoma and total removal of the tumor were performed on April 24. Histopathological diagnosis was adenocarcinoma. It was the same finding as that of the previous breast cancer. Histopathological examination revealed necrosis without tumor cells in the center and residual tumor cells in the peripheral part of the tumor. It is postulated that peritumoral hemorrhage was caused by hemodynamic changes in the vascular-rich tumor after radiosurgery and breakdown of the fragile abnormal vessels in the peripheral part of the tumor. (author).

  7. Radiosurgery and the double logistic product formula

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Steiner, L.

    1990-01-01

    The double logistic product formula is proposed as a method for predicting the probability of developing brain necrosis after high dose irradiation of small target volumes as used in stereotactic radiosurgery. Dose-response data observed for the production of localized radiation necreosis for treating intractable pain with the original Leksell gamma unit were used to choose the best fitting parameters for the double logistic product formula. This model can be used with either exponential or linear quadratic formulas to account for the effects of dose, fractionation and time in addition to volume. Dose-response predictions for stereotactic radiosurgery with different sized collimators are presented. (author). 41 refs.; 5 figs.; 1 tab

  8. Small photon beam measurements using radiochromic film and Monte Carlo simulations in a water phantom

    International Nuclear Information System (INIS)

    Garcia-Garduno, Olivia A.; Larraga-Gutierrez, Jose M.; Rodriguez-Villafuerte, Mercedes; Martinez-Davalos, Arnulfo; Celis, Miguel A.

    2010-01-01

    This work reports the use of both GafChromic EBT film immersed in a water phantom and Monte Carlo (MC) simulations for small photon beam stereotactic radiosurgery dosimetry. Circularly collimated photon beams with diameters in the 4-20 mm range of a dedicated 6 MV linear accelerator (Novalis (registered) , BrainLAB, Germany) were used to perform off-axis ratios, tissue maximum ratios and total scatter factors measurements, and MC simulations. GafChromic EBT film data show an excellent agreement with MC results (<2.7%) for all measured quantities.

  9. Parallel Monte Carlo simulation of aerosol dynamics

    KAUST Repository

    Zhou, K.; He, Z.; Xiao, M.; Zhang, Z.

    2014-01-01

    is simulated with a stochastic method (Marcus-Lushnikov stochastic process). Operator splitting techniques are used to synthesize the deterministic and stochastic parts in the algorithm. The algorithm is parallelized using the Message Passing Interface (MPI

  10. Improved results for vestibular schwannoma radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kondziolka, D; Pollock, B; Lunsford, L D

    1995-07-01

    PURPOSE/OBJECTIVE: Treatment techniques in radiosurgery have changed since 1987. We reviewed patients who received radiosurgery for vestibular schwannoma to identify these changes and to investigate any differences in tumor control and complications. MATERIALS and METHODS: One hundred thirty-eight unilateral vestibular schwannoma patients with a minimum follow-up of two years after treatment with gamma knife radiosurgery between 1987 and 1992 were analyzed. The early treatment group consisted of 55 patients treated between 1987-1989 (median: tumor volume 3.63 cc, Dmin 18.1 Gy, Dmax 35.4 Gy, isocenters 2.3, follow-up 50.4 mos.). The later treatment group consisted of 83 patients treated between 1990-1992 (median: tumor volume 3.81 cc, Dmin 16.0 Gy, Dmax 31.6 Gy, isocenters 4.7, follow-up 35.8 mos.) RESULTS: Clinical tumor recurrence requiring surgical intervention occurred in one patient in each group. The overall actuarial clinical tumor control rate was 98%. Slight increases in tumor size (1 to 2 mm) were identified in five other patients not requiring intervention, because of no further tumor growth (n=4) or shrinkage (n=1). This led to an overall radiologic tumor control rate of 92% (not significantly different in either group). Compared to the early treatment group, the incidence of facial neuropathy (temporary or permanent) decreased in the later group (49% vs. 11%, p < 0.0001), as did trigeminal neuropathy (40% vs. 8%, p < 0.0001). Serviceable hearing preservation improved only slightly in the later group (27% vs. 40%, p = 0.70). CONCLUSION: We document a significant decrease in the morbidity of vestibular schwannoma radiosurgery over this time period with no decrease in the high rate of tumor control. This improvement is attributed to a) better conformal dose-planning with stereotactic MRI rather than CT, b) an increase in the number of isocenters used, and c) a reduction in the average dose administered by 2 Gy.

  11. Linear accelerator radiosurgery for arteriovenous malformations: Updated literature review.

    Science.gov (United States)

    Yahya, S; Heyes, G; Nightingale, P; Lamin, S; Chavda, S; Geh, I; Spooner, D; Cruickshank, G; Sanghera, P

    2017-04-01

    Arteriovenous malformations (AVMs) are the leading causing of intra-cerebral haemorrhage. Stereotactic radiosurgery (SRS) is an established treatment for arteriovenous malformations (AVM) and commonly delivered using Gamma Knife within dedicated radiosurgery units. Linear accelerator (LINAC) SRS is increasingly available however debate remains over whether it offers an equivalent outcome. The aim of this project is to evaluate the outcomes using LINAC SRS for AVMs used within a UK neurosciences unit and review the literature to aid decision making across various SRS platforms. Results have shown comparability across platforms and strongly supports that an adapted LINAC based SRS facility within a dynamic regional neuro-oncology department delivers similar outcomes (in terms of obliteration and toxicity) to any other dedicated radio-surgical platform. Locally available facilities can facilitate discussion between options however throughput will inevitably be lower than centrally based dedicated national radiosurgery units. Copyright © 2016. Published by Elsevier Ltd.

  12. Stereotactic radiosurgery for brain metastasis: Pitie-Salpetriere Hospital experience

    International Nuclear Information System (INIS)

    Feuvret, L.; Germain, I.; Cornu, P.; Boisserie, G.; Dormont, D.; Hardiman, C.; Tep, B.; Faillot, T.; Duffau, H.; Simon, J.M.; Dendale, R.; Delattre, J.Y.; Poisson, M.; Marsault, C.; Philippon, J.; Fohanno, D.; Baillet, F.; Mazeron, J.J.

    1998-01-01

    Retrospective analysis of the influence of clinical and technical factors on local control and survival after radiosurgery for brain metastasis. From january 1994 to December 1996, 42 patients presenting with 71 metastases underwent radiosurgery for brain metastasis. The median age was 56 years and the median Karnofsky index 80. Primary sites included: lung (20 patients), kidney (seven), breast (five), colon (two), melanoma (three), osteosarcoma (one) and it was unknown for three patients. Seventeen patients had extracranial metastasis. Twenty-four patients were treated at recurrence which occurred after whole brain irradiation (12 patients), surgical excision (four) or after both treatments (eight). Thirty-six sessions of radiosurgery have been realized for one metastasis and 13 for two, three or four lesions. The median metastasis diameter was 21 mm and the median volume 1.7 cm 3 . The median peripheral dose to the lesion was 14 Gy, and the median dose at the isocenter 20 Gy. Sixty-five metastasis were evaluable for response analysis. The overall local control rate was 82% and the 1-year actuarial rate was 72%. In univariate analysis, theoretical radioresistance (P = 0.001), diameter less than 3 cm (P = 0.039) and initial treatment with radiosurgery (P 0.041) were significantly associated with increased local control. Only the first two factors remained significant in multivariate analysis. No prognostic factor of overall survival was identified. The median survival was 12 months. Six patients had a symptomatic oedema (RTOG grade 2), only one of which requiring a surgical excision. In conclusion, 14 Gy delivered at the periphery of metastasis seems to be a sufficient dose to control most brain metastases, with a minimal toxicity. Better results were obtained for lesions initially treated with radiosurgery, theoretically radioresistant and with a diameter less than 3 cm. (authors)

  13. The current role of Gamma Knife radiosurgery in the management of intracranial haemangiopericytoma.

    Science.gov (United States)

    Spina, Alfio; Boari, Nicola; Gagliardi, Filippo; Donofrio, Carmine A; Franzin, Alberto; Mortini, Pietro

    2016-04-01

    Haemangiopericytomas (HPCs) are rare tumours characterised by aggressive behaviour with tendency to local recurrence and to metastasise. WHO grade II and grade III tumours show different progression-free survival and overall survival rates. Gross total tumour resection is still considered the treatment of choice. Adjuvant radiation therapies represent an option in the treatment strategy regardless the extent of resection. Based on this consideration, Gamma Knife radiosurgery has been introduced either as a primary treatment or as an adjuvant treatment for residual or recurrent tumours. A systematic search was performed on PubMed, Web of Science and Google Scholar for clinical series reporting Gamma Knife radiosurgery, Cyberknife and Linear Accelerator (LINAC) for the management of intracranial HPCs. Fourteen studies focusing on the effects of Gamma Knife radiosurgery for intracranial HPCs were included. Four studies reported data on Cyberknife radiosurgery and LINAC. A total of 208 patients harbouring 366 tumours have been reported. Patient's features, radiosurgical treatment characteristics and follow-up data of the pertinent literature have been critically revised. Gamma Knife radiosurgery and the other radiosurgical techniques represent a feasible and effective therapy in the management of HPCs. Tumour control and survival rate are comparable to those reported for radiotherapy. Further studies should be focused to define the exact role of Gamma Knife radiosurgery in the management of HPCs.

  14. Radiosurgery for brain metastases: a score index for predicting prognosis

    International Nuclear Information System (INIS)

    Weltman, Eduardo; Salvajoli, Joao Victor; Brandt, Reynaldo Andre; Morais Hanriot, Rodrigo de; Prisco, Flavio Eduardo; Cruz, Jose Carlos; Oliveira Borges, Sandra Regina de; Wajsbrot, Dalia Ballas

    2000-01-01

    Purpose: To analyze a prognostic score index for patients with brain metastases submitted to stereotactic radiosurgery (the Score Index for Radiosurgery in Brain Metastases [SIR]). Methods and Materials: Actuarial survival of 65 brain metastases patients treated with radiosurgery between July 1993 and December 1997 was retrospectively analyzed. Prognostic factors included age, Karnofsky performance status (KPS), extracranial disease status, number of brain lesions, largest brain lesion volume, lesions site, and receiving or not whole brain irradiation. The SIR was obtained through summation of the previously noted first five prognostic factors. Kaplan-Meier actuarial survival curves for all prognostic factors, SIR, and recursive partitioning analysis (RPA) (RTOG prognostic score) were calculated. Survival curves of subsets were compared by log-rank test. Application of the Cox model was utilized to identify any correlation between prognostic factors, prognostic scores, and survival. Results: Median overall survival from radiosurgery was 6.8 months. Utilizing univariate analysis, extracranial disease status, KPS, number of brain lesions, largest brain lesion volume, RPA, and SIR were significantly correlated with prognosis. Median survival for the RPA classes 1, 2, and 3 was 20.19 months, 7.75 months, and 3.38 months respectively (p = 0.0131). Median survival for patients, grouped under SIR from 1 to 3, 4 to 7, and 8 to 10, was 2.91 months, 7.00 months, and 31.38 months respectively (p = 0.0001). Using the Cox model, extracranial disease status and KPS demonstrated significant correlation with prognosis (p 0.0001 and 0.0004 respectively). Multivariate analysis also demonstrated significance for SIR and RPA when tested individually (p = 0.0001 and 0.0040 respectively). Applying the Cox Model to both SIR and RPA, only SIR reached independent significance (p = 0.0004). Conclusions: Systemic disease status, KPS, SIR, and RPA are reliable prognostic factors for patients

  15. Radiosurgery of Glomus Jugulare Tumors: A Meta-Analysis

    International Nuclear Information System (INIS)

    Guss, Zachary D.; Batra, Sachin; Limb, Charles J.; Li, Gordon; Sughrue, Michael E.; Redmond, Kristin; Rigamonti, Daniele; Parsa, Andrew T.; Chang, Steven; Kleinberg, Lawrence; Lim, Michael

    2011-01-01

    Purpose: During the past two decades, radiosurgery has arisen as a promising approach to the management of glomus jugulare. In the present study, we report on a systematic review and meta-analysis of the available published data on the radiosurgical management of glomus jugulare tumors. Methods and Materials: To identify eligible studies, systematic searches of all glomus jugulare tumors treated with radiosurgery were conducted in major scientific publication databases. The data search yielded 19 studies, which were included in the meta-analysis. The data from 335 glomus jugulare patients were extracted. The fixed effects pooled proportions were calculated from the data when Cochrane's statistic was statistically insignificant and the inconsistency among studies was 36 months. In these studies, 95% of patients achieved clinical control and 96% achieved tumor control. The gamma knife, linear accelerator, and CyberKnife technologies all exhibited high rates of tumor and clinical control. Conclusions: The present study reports the results of a meta-analysis for the radiosurgical management of glomus jugulare. Because of its high effectiveness, we suggest considering radiosurgery for the primary management of glomus jugulare tumors.

  16. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    International Nuclear Information System (INIS)

    Karpinos, Marianna; Teh, Bin S.; Zeck, Otto; Carpenter, L. Steven; Phan, Chris; Mai, W.-Y.; Lu, Hsin H.; Chiu, J. Kam; Butler, E. Brian; Gormley, William B.; Woo, Shiao Y.

    2002-01-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small 4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35.3% vs. 6.1%, p=0.008, at long

  17. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    Energy Technology Data Exchange (ETDEWEB)

    Karpinos, Marianna; Teh, Bin S; Zeck, Otto; Carpenter, L Steven; Phan, Chris; Mai, W -Y; Lu, Hsin H; Chiu, J Kam; Butler, E Brian; Gormley, William B; Woo, Shiao Y

    2002-12-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small <2.0 cm, medium 2.0-3.9 cm, or large >4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35

  18. Results of stereotactic radiosurgery for patients with imaging defined cavernous sinus meningiomas

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Stafford, Scott L.

    2005-01-01

    Introduction: The purpose of this study was to evaluate the efficacy and safety of stereotactic radiosurgery as primary management for patients with imaging defined cavernous sinus meningiomas. Methods: Between 1992 and 2001, 49 patients had radiosurgery for dural-based masses of the cavernous sinus presumed to be meningiomas. The mean patient age was 55.5 years. The mean tumor volume was 10.2 mL; the mean tumor margin dose was 15.9 Gy. The mean follow-up was 58 months (range, 16-144 months). Results: No tumor enlarged after radiosurgery. Twelve of 38 patients (26%) with preexisting diplopia or facial numbness/pain had improvement in cranial nerve function. Five patients (10%) had new (n = 3) or worsened (n = 2) trigeminal dysfunction; 2 of these patients (4%) underwent surgery at 20 and 25 months after radiosurgery despite no evidence of tumor progression. Neither patient improved after partial tumor resection. One patient (2%) developed an oculomotor nerve injury. One patient (2%) had an ischemic stroke related to occlusion of the cavernous segment of the internal carotid artery. Event-free survival was 98%, 85%, and 80% at 1, 3, and 7 years after radiosurgery, respectively. Univariate analysis of patient and dosimetric factors found no analyzed factor correlated with postradiosurgical morbidity. Conclusions: Radiosurgery was an effective primary management strategy for patients with an imaging defined cavernous sinus meningioma. Except in situations of symptomatic mass effect, unusual clinical presentation, or atypical imaging features, surgery to confirm the histologic diagnosis is unlikely to provide clinical benefit

  19. Parallelized event chain algorithm for dense hard sphere and polymer systems

    International Nuclear Information System (INIS)

    Kampmann, Tobias A.; Boltz, Horst-Holger; Kierfeld, Jan

    2015-01-01

    We combine parallelization and cluster Monte Carlo for hard sphere systems and present a parallelized event chain algorithm for the hard disk system in two dimensions. For parallelization we use a spatial partitioning approach into simulation cells. We find that it is crucial for correctness to ensure detailed balance on the level of Monte Carlo sweeps by drawing the starting sphere of event chains within each simulation cell with replacement. We analyze the performance gains for the parallelized event chain and find a criterion for an optimal degree of parallelization. Because of the cluster nature of event chain moves massive parallelization will not be optimal. Finally, we discuss first applications of the event chain algorithm to dense polymer systems, i.e., bundle-forming solutions of attractive semiflexible polymers

  20. SU-E-J-34: Clinical Evaluation of Targeting Accuracy and Tractogrphy Delineation of Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R; Suh, T; Kim, Y; Han, J; Kim, C; Oh, C; Kim, D [Seoul National University Bundang Hospital (Korea, Republic of)

    2014-06-01

    Purpose: Focal radiosurgery is a common treatment modality for trigeminal neuralgia (TN), a neuropathic facial pain condition. Assessment of treatment effectiveness is primarily clinical, given the paucity of investigational tools to assess trigeminal nerve changes. The efficiency of radiosurgery is related to its highly precise targeting. We assessed clinically the targeting accuracy of radiosurgery with Gamma knife. We hypothesized that trigeminal tractography provides more information than 2D-MR imaging, allowing detection of unique, focal changes in the target area after radiosurgery. Methods: Sixteen TN patients (2 females, 4 male, average age 65.3 years) treated with Gamma Knife radiosurgery, 40 Gy/50% isodose line underwent 1.5Tesla MR trigeminal nerve . Target accuracy was assessed from deviation of the coordinates of the target compared with the center of enhancement on post MRI. Radiation dose delivered at the borders of contrast enhancement was evaluated Results: The median deviation of the coordinates between the intended target and the center of contrast enhancement was within 1mm. The radiation doses fitting within the borders of the contrast enhancement the target ranged from 37.5 to 40 Gy. Trigeminal tractography accurately detected the radiosurgical target. Radiosurgery resulted in 47% drop in FA values at the target with no significant change in FA outside the target, suggesting that radiosurgery primarily affects myelin. Tractography was more sensitive, since FA changes were detected regardless of trigeminal nerve enhancement Conclusion: The median deviation found in clinical assessment of gamma knife treatment for TN Is low and compatible with its high rate of efficiency. DTI parameters accurately detect the effects of focal radiosurgery on the trigeminal nerve, serving as an in vivo imaging tool to study TN. This study is a proof of principle for further assessment of DTI parameters to understand the pathophysiology of TN and treatment effects.

  1. Objective specific beam generation for image guided robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, A.; Jungmann, O.; Schweikard, A.; Kilby, W.

    2007-01-01

    Robotic radiosurgery enables precise dose delivery throughout the body. Planning for robotic radiosurgery comprises of finding a suitable set of beams and beam weights. The problem can be addressed by generating a large set of candidate beams, and selection of beams with nonzero weight by mathematical programming. We propose to use different randomized beam generation methods depending on the type of lesion and the clinical objective. Results for three patient cases indicate that this can improve the plan quality. (orig.)

  2. Objective specific beam generation for image guided robotic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Schlaefer, A.; Jungmann, O.; Schweikard, A. [Inst. for Robotics and Cognitive Systems, Univ. of Luebeck (Germany); Kilby, W. [Accuray Inc., Sunnyvale, CA (United States)

    2007-06-15

    Robotic radiosurgery enables precise dose delivery throughout the body. Planning for robotic radiosurgery comprises of finding a suitable set of beams and beam weights. The problem can be addressed by generating a large set of candidate beams, and selection of beams with nonzero weight by mathematical programming. We propose to use different randomized beam generation methods depending on the type of lesion and the clinical objective. Results for three patient cases indicate that this can improve the plan quality. (orig.)

  3. Stereotactic Radiosurgery and Hypofractionated Radiotherapy for Glioblastoma.

    Science.gov (United States)

    Shah, Jennifer L; Li, Gordon; Shaffer, Jenny L; Azoulay, Melissa I; Gibbs, Iris C; Nagpal, Seema; Soltys, Scott G

    2018-01-01

    Glioblastoma is the most common primary brain tumor in adults. Standard therapy depends on patient age and performance status but principally involves surgical resection followed by a 6-wk course of radiation therapy given concurrently with temozolomide chemotherapy. Despite such treatment, prognosis remains poor, with a median survival of 16 mo. Challenges in achieving local control, maintaining quality of life, and limiting toxicity plague treatment strategies for this disease. Radiotherapy dose intensification through hypofractionation and stereotactic radiosurgery is a promising strategy that has been explored to meet these challenges. We review the use of hypofractionated radiotherapy and stereotactic radiosurgery for patients with newly diagnosed and recurrent glioblastoma. Copyright © 2017 by the Congress of Neurological Surgeons.

  4. Stereotactic radiosurgery. The role of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M. [Loma Linda Univ. Medical Center, CA (United States). Dept. of Radiation Medicine

    1999-08-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  5. Stereotactic radiosurgery. The role of charged particles

    International Nuclear Information System (INIS)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M.

    1999-01-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  6. Imitation Monte Carlo methods for problems of the Boltzmann equation with small Knudsen numbers, parallelizing algorithms with splitting

    International Nuclear Information System (INIS)

    Khisamutdinov, A I; Velker, N N

    2014-01-01

    The talk examines a system of pairwise interaction particles, which models a rarefied gas in accordance with the nonlinear Boltzmann equation, the master equations of Markov evolution of this system and corresponding numerical Monte Carlo methods. Selection of some optimal method for simulation of rarefied gas dynamics depends on the spatial size of the gas flow domain. For problems with the Knudsen number K n of order unity 'imitation', or 'continuous time', Monte Carlo methods ([2]) are quite adequate and competitive. However if K n ≤ 0.1 (the large sizes), excessive punctuality, namely, the need to see all the pairs of particles in the latter, leads to a significant increase in computational cost(complexity). We are interested in to construct the optimal methods for Boltzmann equation problems with large enough spatial sizes of the flow. Speaking of the optimal, we mean that we are talking about algorithms for parallel computation to be implemented on high-performance multi-processor computers. The characteristic property of large systems is the weak dependence of sub-parts of each other at a sufficiently small time intervals. This property is taken into account in the approximate methods using various splittings of operator of corresponding master equations. In the paper, we develop the approximate method based on the splitting of the operator of master equations system 'over groups of particles' ([7]). The essence of the method is that the system of particles is divided into spatial subparts which are modeled independently for small intervals of time, using the precise 'imitation' method. The type of splitting used is different from other well-known type 'over collisions and displacements', which is an attribute of the known Direct simulation Monte Carlo methods. The second attribute of the last ones is the grid of the 'interaction cells', which is completely absent in the imitation methods. The

  7. Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Hawkins, Maria; Flentje, Michael; Sweeney, Reinhart A

    2012-01-01

    One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70% of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery – have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1) A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2) Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions) or intermediate (5 fractions) life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3) Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥ 2 points at the treated vertebral site on the 0 to 10 Visual Analogue Scale. 60 patients

  8. Linac based radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    The following topics were discussed: Definition of stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Stereo market; Indications for SRS/SRT; History of linac-based SRS/SRT; Variety of systems; QA for SRS; Localization; and Imaging. (P.A.)

  9. Role of gamma knife radiosurgery in neurosurgery. Past and future perspectives

    International Nuclear Information System (INIS)

    Koga, Tomoyuki; Shin, Masahiro; Saito, Nobuhito

    2010-01-01

    The gamma knife was the first radiosurgical device developed at the Karolinska Institute in 1967. Stereotactic radiosurgery using the gamma knife has been widely accepted in clinical practice and has contributed to the development of neurosurgery. More than 500,000 patients have been treated by gamma knife stereotactic radiosurgery so far, and the method is now an indispensable neurosurgical tool. Here we review long-term outcomes and development of stereotactic radiosurgery using the gamma knife and discuss its future perspectives. The primary role of stereotactic radiosurgery is to control small well-demarcated lesions such as metastatic brain tumors, meningiomas, schwannomas, and pituitary adenomas while preserving the function of surrounding brain tissue. The gamma knife has been used as a primary treatment or in combination with surgery, and some applications have been accepted as standard treatment in the field of neurosurgery. Treatment of cerebral arteriovenous malformations has also been drastically changed after emergence of this technology. Controlling functional disorders is another role of stereotactic radiosurgery. There is a risk of radiation-induced adverse events, which are usually mild and less frequent. However, especially in large or invasive lesions, those risks are not negligible and pose limitations. Advancement of irradiation technology and dose planning software have enabled more sophisticated and safer treatment, and further progress will contribute to better treatment outcomes not only for brain lesions but also for cervical lesions with less invasive treatment. (author)

  10. Analysis of neurological sequelae from radiosurgery of arteriovenous malformations: how location effects outcome

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Maitz, Ann H.; Lunsford, L. Dade

    1997-01-01

    Purpose/Objective: To elucidate how the risks of developing temporary and permanent neurological sequelae from radiosurgery for arteriovenous malformations (AVM) relate to AVM location, the addition of stereotactic magnetic resonance (MR) imaging to angiographic targeting, and prior hemorrhage or neurological deficits. Materials and Methods: We evaluated follow-up imaging and clinical data in 332 AVM patients who received gamma knife radiosurgery at the University of Pittsburgh between 1987 and 1994. All patients had regular clinical or imaging follow up for a minimum of two years (range: 24-96 mo., median=45 mo.). 83 patients had MR. planning, and 187 previously bled. Results: Symptomatic post-radiosurgery sequelae (any neurological problem including headache) developed in 30/332 patients (9.0%). Symptoms resolved in 58% of patients within 24 mo. with a significantly greater proportion (p=0.006) resolving in patients with Dmin <20 vs. ≥20 Gy (89 vs. 36%). The 7 yr. actuarial rate for developing persistent symptomatic sequelae was 3.8%. We first evaluated the relative risks for different locations to construct a post-radiosurgery injury expression (PIE) score for AVM location (see Table 1). Multivariate logistic regression analysis of symptomatic post-radiosurgery injury identified independent significant correlations with PIE location score (p=0.0007) and 12 Gy volume (p=0.008) but none of the other factors tested (p≥0.3) including the addition of MR targeting, average radiation dose in 20 cc, prior bleed or neurological deficit. We used these results to construct risk prediction models for any symptomatic post-radiosurgery sequelae and for symptomatic necrosis. Conclusion: The risks of complications from AVM radiosurgery can be predicted according to location with the PIE score and by the 12 Gy treatment volume (Table 2)

  11. Dose-Escalation Study for Cardiac Radiosurgery in a Porcine Model

    Energy Technology Data Exchange (ETDEWEB)

    Blanck, Oliver, E-mail: oliver.blanck@uksh.de [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); CyberKnife Center Northern Germany, Guestrow (Germany); Bode, Frank [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Gebhard, Maximilian [Institute of Pathology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Hunold, Peter [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Brandt, Sebastian [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Bruder, Ralf [Institute for Robotics and Cognitive Systems, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Grossherr, Martin [Department of Anaesthesiology and Intensive Care Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Vonthein, Reinhard [Institute of Medical Biometry and Statistics, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Rades, Dirk [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); Dunst, Juergen [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck (Germany); University Copenhagen (Denmark)

    2014-07-01

    Purpose: To perform a proof-of-principle dose-escalation study to radiosurgically induce scarring in cardiac muscle tissue to block veno-atrial electrical connections at the pulmonary vein antrum, similar to catheter ablation. Methods and Materials: Nine mini-pigs underwent pretreatment magnetic resonance imaging (MRI) evaluation of heart function and electrophysiology assessment by catheter measurements in the right superior pulmonary vein (RSPV). Immediately after examination, radiosurgery with randomized single-fraction doses of 0 and 17.5-35 Gy in 2.5-Gy steps were delivered to the RSPV antrum (target volume 5-8 cm{sup 3}). MRI and electrophysiology were repeated 6 months after therapy, followed by histopathologic examination. Results: Transmural scarring of cardiac muscle tissue was noted with doses ≥32.5 Gy. However, complete circumferential scarring of the RSPV was not achieved. Logistic regressions showed that extent and intensity of fibrosis significantly increased with dose. The 50% effective dose for intense fibrosis was 31.3 Gy (odds ratio 2.47/Gy, P<.01). Heart function was not affected, as verified by MRI and electrocardiogram evaluation. Adjacent critical structures were not damaged, as verified by pathology, demonstrating the short-term safety of small-volume cardiac radiosurgery with doses up to 35 Gy. Conclusions: Radiosurgery with doses >32.5 Gy in the healthy pig heart can induce circumscribed scars at the RSPV antrum noninvasively, mimicking the effect of catheter ablation. In our study we established a significant dose-response relationship for cardiac radiosurgery. The long-term effects and toxicity of such high radiation doses need further investigation in the pursuit of cardiac radiosurgery for noninvasive treatment of atrial fibrillation.

  12. Complications from arteriovenous malformation radiosurgery: multivariate analysis and risk modeling

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Pollock, Bruce E.; Maitz, Ann H.; Lunsford, L. Dade

    1997-01-01

    Purpose/Objective: To assess the relationships of radiosurgery treatment parameters to the development of complications from radiosurgery for arteriovenous malformations (AVM). Methods and Materials: We evaluated follow-up imaging and clinical data in 307 AVM patients who received gamma knife radiosurgery at the University of Pittsburgh between 1987 and 1993. All patients had regular clinical or imaging follow up for a minimum of 2 years (range: 24-96 months, median = 44 months). Results: Post-radiosurgical imaging (PRI) changes developed in 30.5% of patients with regular follow-up magnetic resonance imaging, and were symptomatic in 10.7% of all patients at 7 years. PRI changes resolved within 3 years developed significantly less often (p = 0.0274) in patients with symptoms (52.8%) compared to asymptomatic patients (94.8%). The 7-year actuarial rate for developing persistent symptomatic PRI changes was 5.05%. Multivariate logistic regression modeling found that the 12 Gy volume was the only independent variable that correlated significantly with PRI changes (p < 0.0001) while symptomatic PRI changes were correlated with both 12 Gy volume (p = 0.0013) and AVM location (p 0.0066). Conclusion: Complications from AVM radiosurgery can be predicted with a statistical model relating the risks of developing symptomatic post-radiosurgical imaging changes to 12 Gy treatment volume and location

  13. Stereotactic radiosurgery using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kyuma, Yoshikazu; Hayashi, Akimune; Kitamura, Tatsuo; Yamashita, Koosuke; Muranishi, Hisayuki; Hioki, Minoru [Kanagawa Cancer Center, Yokohama (Japan)

    1992-07-01

    A basic and clinical study of radiosurgery using the linear accelerator (Linac) system for unremovable deep-seated brain tumors is reported. A Komai stereotactic ring was used to locate the target coordinates. The patient was laid on the Linac treatment table and held in the head fixation system. Irradiation was given in five positions. The dose profile by film dosimetry and Rando phantom was satisfactory. Seventeen tumors in 14 patients were treated. Clinical or histological diagnoses were nine metastases, one benign and two malignant gliomas, one meningioma, and one carcinopharyngioma. Tumor sizes were between 8 and 30 mm. Doses were between 12 and 30 Gy. Computed tomographic evaluation after 3 months of 12 tumors in 11 survivors showed one complete remission, three partial remission, six no change, and two partial deterioration. For progressive tumors, Linac radiosurgery results are excellent. (author).

  14. Therapeutic profile of single-fraction radiosurgery of vestibular schwannoma: unrelated malignancy predicts tumor control

    Science.gov (United States)

    Wowra, Berndt; Muacevic, Alexander; Fürweger, Christoph; Schichor, Christian; Tonn, Jörg-Christian

    2012-01-01

    Radiosurgery has become an accepted treatment option for vestibular schwannomas. Nevertheless, predictors of tumor control and treatment toxicity in current radiosurgery of vestibular schwannomas are not well understood. To generate new information on predictors of tumor control and cranial nerve toxicity of single-fraction radiosurgery of vestibular schwannomas, we conducted a single-institution long-term observational study of radiosurgery for sporadic vestibular schwannomas. Minimum follow-up was 3 years. Investigated as potential predictors of tumor control and cranial nerve toxicity were treatment technology; tumor resection preceding radiosurgery; tumor size; gender; patient age; history of cancer, vascular disease, or metabolic disease; tumor volume; radiosurgical prescription dose; and isodose line. Three hundred eighty-six patients met inclusion criteria. Treatment failure was observed in 27 patients. History of unrelated cancer (strongest predictor) and prescription dose significantly predicted tumor control. The cumulative incidence of treatment failure was 30% after 6.5 years in patients with unrelated malignancy and 10% after ≥15 years in patients without such cancer (P making in ambiguous cases. PMID:22561798

  15. A cost-effectiveness and cost-utility analysis of radiosurgery vs. resection for single-brain metastases

    International Nuclear Information System (INIS)

    Mehta, Minesh; Noyes, William; Craig, Bruce; Lamond, John; Auchter, Richard; French, Molly; Johnson, Mark; Levin, Allan; Badie, Behnam; Robbins, Ian; Kinsella, Timothy

    1997-01-01

    Purpose: The median survival of well-selected patients with single-brain metastases treated with whole-brain irradiation and resection or radiosurgery is comparable, although a randomized trial of these two modalities has not been performed. In this era of cost containment, it is imperative that health-care professionals make fiscally prudent decisions. The present environment necessitates a critical appraisal of apparently equi-efficacious therapeutic modalities, and it is within this context that we present a comparison of the actual costs of resection and radiosurgery for brain metastases. Methods and Materials: Survival and quality of life outcome data for radiation alone or with surgery were obtained from two randomized trials, and radiosurgical results were obtained from a multiinstitutional analysis that specifically evaluated patients meeting surgical criteria. Only linear accelerator radiosurgery data were considered. Cost analysis was performed from a societal view point, and the following parameters were evaluated: actual cost, cost ratios, cost effectiveness, incremental cost effectiveness, cost utility, incremental cost utility, and national cost burden. The computerized billing records for all patients undergoing resection or radiosurgery for single-brain metastases from January 1989 to July 1994 were reviewed. A total of 46 resections and 135 radiosurgery procedures were performed. During the same time period, 454 patients underwent whole-brain radiation alone. An analysis of the entire bill was performed for each procedure, and each itemized cost was assigned a proportionate figure. The relative cost ratios of resection and radiosurgery were compared using the Wilcoxon rank sum test. Cost effectiveness of each modality, defined as the cost per year of median survival, was evaluated. Incremental cost effectiveness, defined as the additional cost per year of incremental gain in median survival, compared to the next least expensive modality, was also

  16. Development of 3-D Radiosurgery Planning System Using IBM Personal Computer

    International Nuclear Information System (INIS)

    Suh, Tae Suk; Park, Charn Il; Ha, Sung Whan; Kang, Wee Saing; Suh, Doug Young; Park, Sung Hun

    1993-01-01

    Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam eye view or CT simulation in radiation therapy in future

  17. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery.

    Science.gov (United States)

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-09-21

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed with a facial schwannoma via a magnetic resonance imaging (MRI) scan of the head and neck and was told to wait until the facial nerve palsy subsides. She was referred to our hospital for radiation therapy. We planned a fractionated CyberKnife radiosurgery for three consecutive days. After CyberKnife radiosurgery, the mass in the right parotid gradually decreased in size, and the facial nerve palsy disappeared. At her eight-month follow-up, her facial spasm had completely disappeared. There has been no recurrence and the facial nerve function has been normal. We successfully demonstrated the efficacy of CyberKnife radiosurgery as an alternative treatment that also preserves neurofunction for facial nerve schwannomas.

  18. Stereotactic radiosurgery for the treatment of brain metastases; results from a single institution experience.

    LENUS (Irish Health Repository)

    Burke, D

    2013-09-01

    Stereotactic radiosurgery is frequently used for the treatment of brain metastases. This study provides a retrospective evaluation of patients with secondary lesions of the brain treated with stereotactic radiosurgery (SRS) at our institution.

  19. Gamma Knife Radiosurgery for Patients With Nonfunctioning Pituitary Adenomas: Results From a 15-Year Experience

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Cochran, Joseph; Natt, Neena; Brown, Paul D.; Erickson, Dana; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.; Stafford, Scott L.; Schomberg, Paula J.

    2008-01-01

    Purpose: To evaluate the efficacy and complications of stereotactic radiosurgery for patients with nonfunctioning pituitary adenomas (NFA). Methods and Materials: This was a retrospective review of 62 patients with NFA undergoing radiosurgery between 1992 and 2004, of whom 59 (95%) underwent prior tumor resection. The median treatment volume was 4.0 cm 3 (range, 0.8-12.9). The median treatment dose to the tumor margin was 16 Gy (range, 11-20). The median maximum point dose to the optic apparatus was 9.5 Gy (range, 5.0-12.6). The median follow-up period after radiosurgery was 64 months (range, 23-161). Results: Tumor size decreased for 37 patients (60%) and remained unchanged for 23 patients (37%). Two patients (3%) had tumor growth outside the prescribed treatment volume and required additional treatment (fractionated radiation therapy, n = 1; repeat radiosurgery, n 1). Tumor growth control was 95% at 3 and 7 years after radiosurgery. Eleven (27%) of 41 patients with normal (n = 30) or partial (n = 11) anterior pituitary function before radiosurgery developed new deficits at a median of 24 months after radiosurgery. The risk of developing new anterior pituitary deficits at 5 years was 32%. The 5-year risk of developing new anterior pituitary deficits was 18% for patients with a tumor volume of ≤4.0 cm 3 compared with 58% for patients with a tumor volume >4.0 cm 3 (risk ratio 4.5; 95% confidence interval = 1.3-14.9, p = 0.02). No patient had a decline in visual function. Conclusions: Stereotactic radiosurgery is effective in the management of patients with residual or recurrent NFA, although longer follow-up is needed to evaluate long-term outcomes. The primary complication is hypopituitarism, and the risk of developing new anterior pituitary deficits correlates with the size of the irradiated tumor

  20. Guideline of Monte Carlo calculation. Neutron/gamma ray transport simulation by Monte Carlo method

    CERN Document Server

    2002-01-01

    This report condenses basic theories and advanced applications of neutron/gamma ray transport calculations in many fields of nuclear energy research. Chapters 1 through 5 treat historical progress of Monte Carlo methods, general issues of variance reduction technique, cross section libraries used in continuous energy Monte Carlo codes. In chapter 6, the following issues are discussed: fusion benchmark experiments, design of ITER, experiment analyses of fast critical assembly, core analyses of JMTR, simulation of pulsed neutron experiment, core analyses of HTTR, duct streaming calculations, bulk shielding calculations, neutron/gamma ray transport calculations of the Hiroshima atomic bomb. Chapters 8 and 9 treat function enhancements of MCNP and MVP codes, and a parallel processing of Monte Carlo calculation, respectively. An important references are attached at the end of this report.

  1. Microsurgical resection of incompletely obliterated intracranial arteriovenous malformations following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Chang, S.D.; Steinberg, G.K.; Levy, R.P.; Marks, M.P.; Frankel, K.A.; Shuster, D.L.; Marcellus, M.L.

    1998-01-01

    Radiosurgery is effective in obliterating small arteriovenous malformations (AVMs), but less successful in thrombosing larger AVMs. This study reviewed patients who underwent surgical resection of their large AVMs following failed radiosurgical obliteration. AVMs from 36 patients (aged 7 to 64 years, mean 29.9) were surgically resected 1 to 11 years after radiosurgery. Initial AVM volumes were 0.7 to 117 cm 3 (mean 21.6 cm 3 ), and radiosurgical doses ranged from 4.6 to 45 Gray equivalent (GyE) (mean 21.1 GyE). Thirty AVMs (83%) were located in eloquent tissue. Venous drainage was deep (14), superficial (13), or both (9). Spetzler grades were II (2), III (12), IV (18), and V (4). Nine patients suffered rehemorrhage after radiosurgery but prior to surgery, while three patients developed radiation necrosis. Twenty-seven patients underwent endovascular embolization prior to surgery. During microsurgical resection, the AVMs were found to be significantly less vascular and more easily resected, compared to AVMs in patients who had not received radiosurgery. Histology showed endothelial proliferation with hyaline and mineralization in vessel walls. Partial or complete thrombosis of some AVM vessels, and evidence of vessel and brain necrosis were noted in many cases. Clinical outcome was excellent or good in 34 cases, with two patients dying of rebleeding from residual AVM. Five patients were neurologically worse following microsurgical resection. Final outcome was largely related to the pretreatment grade. Radiosurgery several years prior to surgical resection appears useful in treating unusually large and complex AVMs. (author)

  2. Vectorization, parallelization and porting of nuclear codes. 2001

    International Nuclear Information System (INIS)

    Akiyama, Mitsunaga; Katakura, Fumishige; Kume, Etsuo; Nemoto, Toshiyuki; Tsuruoka, Takuya; Adachi, Masaaki

    2003-07-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the super computer system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 10 codes in fiscal 2001. In this report, the parallelization of Neutron Radiography for 3 Dimensional CT code NR3DCT, the vectorization of unsteady-state heat conduction code THERMO3D, the porting of initial program of MHD simulation, the tuning of Heat And Mass Balance Analysis Code HAMBAC, the porting and parallelization of Monte Carlo N-Particle transport code MCNP4C3, the porting and parallelization of Monte Carlo N-Particle transport code system MCNPX2.1.5, the porting of induced activity calculation code CINAC-V4, the use of VisLink library in multidimensional two-fluid model code ACD3D and the porting of experiment data processing code from GS8500 to SR8000 are described. (author)

  3. Commissioning of a Monte Carlo treatment planning system for clinical use in radiation therapy; Evaluacion de un sistema de planificacion Monte Carlo de uso clinico para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparcio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrila, J.

    2016-10-01

    The commissioning procedures of a Monte Carlo treatment planning system (MC) for photon beams from a dedicated stereotactic body radiosurgery (SBRT) unit has been reported in this document. XVMC has been the MC Code available in the treatment planning system evaluated (BrainLAB iPlan RT Dose) which is based on Virtual Source Models that simulate the primary and scattered radiation, besides the electronic contamination, using gaussian components for whose modelling are required measurements of dose profiles, percentage depth dose and output factors, performed both in water and in air. The dosimetric accuracy of the particle transport simulation has been analyzed by validating the calculations in homogeneous and heterogeneous media versus measurements made under the same conditions as the dose calculation, and checking the stochastic behaviour of Monte Carlo calculations when using different statistical variances. Likewise, it has been verified how the planning system performs the conversion from dose to medium to dose to water, applying the stopping power ratio water to medium, in the presence of heterogeneities where this phenomenon is relevant, such as high density media (cortical bone). (Author)

  4. Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial

    Directory of Open Access Journals (Sweden)

    Guckenberger Matthias

    2012-11-01

    Full Text Available Abstract Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70% of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery – have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1 A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2 Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions or intermediate (5 fractions life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3 Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. Methods / Design It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥ 2 points at the treated

  5. Experiences with the parallelisation of Monte Carlo problems

    International Nuclear Information System (INIS)

    Schmidt, F.; Dax, W.; Luger, M.

    1990-01-01

    Monte Carlo problems can be parallelized in a natural way. Therefore parallelisation of production codes can be performed quite easily provided the codes are written in FORTRAN and can be transferred to the parallel machine and this machine has a pseudo random number generator available. The MORSE code is a code which can be transferred. We have done this to the CRAY-2 and the 32 processor version of the TX2 which is a binary tree structured parallel machine based on INTEL 80286 processors. We are able to reach efficiencies up to 95% for realistic problems. Thus the same throughput as on one processor on the CRAY-2 could be reached. First experiments on the INTEL i860 based TX3 indicate an additional gain of a factor 100. This will permit the reconsideration of the Monte Carlo method in both nuclear engineering and as a general numerical tool. (author)

  6. Role of Adjuvant Radiosurgery after Thoracoscopic Microsurgical Resection of a Spinal Schwannoma

    Directory of Open Access Journals (Sweden)

    Toba N. Niazi

    2012-01-01

    Full Text Available Stereotactic radiosurgery to benign tumors of the spine has not been advocated as a primary treatment modality because of the favorable prognosis for these lesions after gross-total resection. There is even less evidence regarding its use as an adjuvant to neurosurgical resection of benign recurrent spinal disease. We describe the case of a 30-year-old man with a thoracic spinal schwannoma who had an interval increase of his lesion five months after thoracoscopic microsurgical resection. The patient opted for noninvasive stereotactic radiosurgery in lieu of additional surgical excision and has had stable disease 15 months after radiosurgical treatment with the linear accelerator (LINAC system. In this setting, stereotactic radiosurgery provided a useful adjunct to thoracoscopic microsurgical resection. Future Class I and II evidence should be sought to evaluate the utility of stereotactic radiosurgery as a primary treatment modality or as an adjuvant for microneurosurgical resection of benign spinal lesions in patients who want noninvasive treatment after disease recurrence or who harbor medical comorbidities that would preclude them from being safe surgical candidates.

  7. Massively parallel Monte Carlo. Experiences running nuclear simulations on a large condor cluster

    International Nuclear Information System (INIS)

    Tickner, James; O'Dwyer, Joel; Roach, Greg; Uher, Josef; Hitchen, Greg

    2010-01-01

    The trivially-parallel nature of Monte Carlo (MC) simulations make them ideally suited for running on a distributed, heterogeneous computing environment. We report on the setup and operation of a large, cycle-harvesting Condor computer cluster, used to run MC simulations of nuclear instruments ('jobs') on approximately 4,500 desktop PCs. Successful operation must balance the competing goals of maximizing the availability of machines for running jobs whilst minimizing the impact on users' PC performance. This requires classification of jobs according to anticipated run-time and priority and careful optimization of the parameters used to control job allocation to host machines. To maximize use of a large Condor cluster, we have created a powerful suite of tools to handle job submission and analysis, as the manual creation, submission and evaluation of large numbers (hundred to thousands) of jobs would be too arduous. We describe some of the key aspects of this suite, which has been interfaced to the well-known MCNP and EGSnrc nuclear codes and our in-house PHOTON optical MC code. We report on our practical experiences of operating our Condor cluster and present examples of several large-scale instrument design problems that have been solved using this tool. (author)

  8. Development of a phantom for quality control of radiosurgery

    International Nuclear Information System (INIS)

    Scheidegger Soboll, D.; Reuters Schelin, H.

    2008-01-01

    The aim of this work was to build a phantom for quality control of stereotactic radiosurgery on linear accelerators. The outward appearance is a translucent human head filled with water and enclosing an insert with test objects of known shapes. The phantom was submitted to computerized tomography, magnetic resonance imaging and angiography exams, in order to perform a radiosurgery planning. Contours of the internal structures on the therapy planning system were drawn over the MRI images. Through the image fusion of CT and MRI, the contour data was transferred to CT images. Stereotactic registration of CT and angiography was made. One isocenter treatment was created, and using the stereotactic coordinates given by the therapy planning system, the phantom was placed on a linac. X-ray images were performed in order to verify the final positioning of the planned isocenter. In the whole process the phantom showed usefulness and adequacy for the positioning quality control of stereotactic radiosurgery with linacs, according to the main documents concerning the issue. (author)

  9. Monte Carlo Transport for Electron Thermal Transport

    Science.gov (United States)

    Chenhall, Jeffrey; Cao, Duc; Moses, Gregory

    2015-11-01

    The iSNB (implicit Schurtz Nicolai Busquet multigroup electron thermal transport method of Cao et al. is adapted into a Monte Carlo transport method in order to better model the effects of non-local behavior. The end goal is a hybrid transport-diffusion method that combines Monte Carlo Transport with a discrete diffusion Monte Carlo (DDMC). The hybrid method will combine the efficiency of a diffusion method in short mean free path regions with the accuracy of a transport method in long mean free path regions. The Monte Carlo nature of the approach allows the algorithm to be massively parallelized. Work to date on the method will be presented. This work was supported by Sandia National Laboratory - Albuquerque and the University of Rochester Laboratory for Laser Energetics.

  10. Pathologic effects of gamma-knife radiosurgery on arteriovenous malformations

    International Nuclear Information System (INIS)

    Schneider, B.F.; Eberhard, D.A.; Steiner, L.

    1995-01-01

    Objective: Stereotactic radiosurgery is an effective method for treating many arteriovenous malformations (AVM). Hemodynamic changes and varying degrees of obliteration of an AVM nidus following radiosurgery have been described with angiography, but there have been no detailed reports describing histopathologic changes in AVM after radiation. The purpose of this study was to examine AVM at various times after gamma-knife radiosurgery in order to determine the mechanism of vessel occlusion after this procedure. Methods: Nine AVM specimens were obtained at autopsy or after surgical excision of residual nidus at times ranging from 10 months to more than 5 years after gamma knife radiosurgery. Formalin fixed, paraffin-embedded sections were examined using routine histopathologic stains: hematoxylin and eosin (H and E), Mallory's phosphotungstic acid-hematoxylin (PTAH), Elastic-van Gieson (EVG), and Hematoxylin-van Gieson (HVG). Additionally, immunohistochemical techniques were used to detect: smooth muscle actin (SMA), Factor VIII, and Type IV collagen. Results: Blood vessels within the AVM show progressive occlusion which correlated with the time interval after radiosurgery. The earliest changes after radiation appear to be damage to and loss of endothelial cells. At this early stage of vascular damage fibrin thrombi are sometimes apparent in the lumen of vessels. With time after radiation there is progressive thickening of the intimal layer, due to proliferation of smooth muscle cells. It is clearly demonstrated, immunohistochemically, that this accumulation of cells within the intimal layer reacts positively for smooth muscle actin, and negatively for Factor VIII (an endothelial cell marker). Using immunohistochemistry it is, also, apparent that these smooth muscle cells are surrounded by an extracellular matrix of Type I collagen, which increases in amount and density over time. Ultimately, vessels are completely occluded by an acellular, amorphous hyalin

  11. Do carbamazepine, gabapentin, or other anticonvulsants exert sufficient radioprotective effects to alter responses from trigeminal neuralgia radiosurgery?

    Science.gov (United States)

    Flickinger, John C; Kim, Hyun; Kano, Hideyuki; Greenberger, Joel S; Arai, Yoshio; Niranjan, Ajay; Lunsford, L Dade; Kondziolka, Douglas; Flickinger, John C

    2012-07-15

    Laboratory studies have documented radioprotective effects with carbamazepine. We sought to determine whether carbamazepine or other anticonvulsant/neuroleptic drugs would show significant radioprotective effects in patients undergoing high-dose small-volume radiosurgery for trigeminal neuralgia. We conducted a retrospective review of 200 patients undergoing Gamma Knife (Elekta Instrument AB, Stockholm, Sweden) stereotactic radiosurgery for trigeminal neuralgia between February 1995 and May 2008. We selected patients treated with a maximum dose of 80 Gy with 4-mm diameter collimators, with no previous microvascular decompression, and follow-up ≥6 months (median, 24 months; range, 6-153 months). At the time of radiosurgery, 28 patients were taking no anticonvulsants, 62 only carbamazepine, 35 only gabapentin, 21 carbamazepine plus gabapentin, 17 carbamazepine plus other anticonvulsants, and 9 gabapentin plus other anticonvulsants, and 28 were taking other anticonvulsants or combinations. Pain improvement developed post-radiosurgery in 187 of 200 patients (93.5%). Initial complete pain relief developed in 84 of 200 patients (42%). Post-radiosurgery trigeminal neuropathy developed in 27 of 200 patients (13.5%). We could not significantly correlate pain improvement or initial complete pain relief with use of carbamazepine, gabapentin, or use of any anticonvulsants/neuroleptic drugs or other factors in univariate or multivariate analysis. Post-radiosurgery numbness/paresthesias correlated with the use of gabapentin (1 of 36 patients with gabapentin vs. 7 of 28 without, p = 0.017). In multivariate analysis, decreasing age, purely typical pain, and use of gabapentin correlated (p = 0.008, p = 0.005, and p = 0.021) with lower risks of developing post-radiosurgery trigeminal neuropathy. New post-radiosurgery numbness/paresthesias developed in 3% (1 of 36), 5% (4 of 81), and 13% (23 of 187) of patients on gabapentin alone, with age ≤70 years, and Type 1 typical

  12. Do Carbamazepine, Gabapentin, or Other Anticonvulsants Exert Sufficient Radioprotective Effects to Alter Responses From Trigeminal Neuralgia Radiosurgery?

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, John C. [Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); College of Arts and Sciences, University of Pittsburgh, Pittsburgh, PA (United States); Kim, Hyun [Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Kano, Hideyuki [Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Greenberger, Joel S.; Arai, Yoshio [Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Pittsburgh Cancer Institute, Pittsburgh, PA (United States); Niranjan, Ajay [Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Lunsford, L. Dade; Kondziolka, Douglas [Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Pittsburgh Cancer Institute, Pittsburgh, PA (United States); Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Flickinger, John C., E-mail: flickingerjc@upmc.edu [Department of Radiation Oncology, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States); Pittsburgh Cancer Institute, Pittsburgh, PA (United States); Department of Neurological Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA (United States)

    2012-07-15

    Purpose: Laboratory studies have documented radioprotective effects with carbamazepine. We sought to determine whether carbamazepine or other anticonvulsant/neuroleptic drugs would show significant radioprotective effects in patients undergoing high-dose small-volume radiosurgery for trigeminal neuralgia. Methods and Materials: We conducted a retrospective review of 200 patients undergoing Gamma Knife (Elekta Instrument AB, Stockholm, Sweden) stereotactic radiosurgery for trigeminal neuralgia between February 1995 and May 2008. We selected patients treated with a maximum dose of 80 Gy with 4-mm diameter collimators, with no previous microvascular decompression, and follow-up {>=}6 months (median, 24 months; range, 6-153 months). At the time of radiosurgery, 28 patients were taking no anticonvulsants, 62 only carbamazepine, 35 only gabapentin, 21 carbamazepine plus gabapentin, 17 carbamazepine plus other anticonvulsants, and 9 gabapentin plus other anticonvulsants, and 28 were taking other anticonvulsants or combinations. Results: Pain improvement developed post-radiosurgery in 187 of 200 patients (93.5%). Initial complete pain relief developed in 84 of 200 patients (42%). Post-radiosurgery trigeminal neuropathy developed in 27 of 200 patients (13.5%). We could not significantly correlate pain improvement or initial complete pain relief with use of carbamazepine, gabapentin, or use of any anticonvulsants/neuroleptic drugs or other factors in univariate or multivariate analysis. Post-radiosurgery numbness/paresthesias correlated with the use of gabapentin (1 of 36 patients with gabapentin vs. 7 of 28 without, p = 0.017). In multivariate analysis, decreasing age, purely typical pain, and use of gabapentin correlated (p = 0.008, p = 0.005, and p = 0.021) with lower risks of developing post-radiosurgery trigeminal neuropathy. New post-radiosurgery numbness/paresthesias developed in 3% (1 of 36), 5% (4 of 81), and 13% (23 of 187) of patients on gabapentin alone, with age

  13. Do Carbamazepine, Gabapentin, or Other Anticonvulsants Exert Sufficient Radioprotective Effects to Alter Responses From Trigeminal Neuralgia Radiosurgery?

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kim, Hyun; Kano, Hideyuki; Greenberger, Joel S.; Arai, Yoshio; Niranjan, Ajay; Lunsford, L. Dade; Kondziolka, Douglas; Flickinger, John C.

    2012-01-01

    Purpose: Laboratory studies have documented radioprotective effects with carbamazepine. We sought to determine whether carbamazepine or other anticonvulsant/neuroleptic drugs would show significant radioprotective effects in patients undergoing high-dose small-volume radiosurgery for trigeminal neuralgia. Methods and Materials: We conducted a retrospective review of 200 patients undergoing Gamma Knife (Elekta Instrument AB, Stockholm, Sweden) stereotactic radiosurgery for trigeminal neuralgia between February 1995 and May 2008. We selected patients treated with a maximum dose of 80 Gy with 4-mm diameter collimators, with no previous microvascular decompression, and follow-up ≥6 months (median, 24 months; range, 6–153 months). At the time of radiosurgery, 28 patients were taking no anticonvulsants, 62 only carbamazepine, 35 only gabapentin, 21 carbamazepine plus gabapentin, 17 carbamazepine plus other anticonvulsants, and 9 gabapentin plus other anticonvulsants, and 28 were taking other anticonvulsants or combinations. Results: Pain improvement developed post-radiosurgery in 187 of 200 patients (93.5%). Initial complete pain relief developed in 84 of 200 patients (42%). Post-radiosurgery trigeminal neuropathy developed in 27 of 200 patients (13.5%). We could not significantly correlate pain improvement or initial complete pain relief with use of carbamazepine, gabapentin, or use of any anticonvulsants/neuroleptic drugs or other factors in univariate or multivariate analysis. Post-radiosurgery numbness/paresthesias correlated with the use of gabapentin (1 of 36 patients with gabapentin vs. 7 of 28 without, p = 0.017). In multivariate analysis, decreasing age, purely typical pain, and use of gabapentin correlated (p = 0.008, p = 0.005, and p = 0.021) with lower risks of developing post-radiosurgery trigeminal neuropathy. New post-radiosurgery numbness/paresthesias developed in 3% (1 of 36), 5% (4 of 81), and 13% (23 of 187) of patients on gabapentin alone, with

  14. Proton beam stereotactic radiosurgery of vestibular schwannomas

    International Nuclear Information System (INIS)

    Harsh, Griffith R.; Thornton, Allan F.; Chapman, Paul H.; Bussiere, Marc R.; Rabinov, James D.; Loeffler, Jay S.

    2002-01-01

    Purpose: The proton beam's Bragg peak permits highly conformal radiation of skull base tumors. This study, prompted by reports of transient (30% each) and permanent (10% each) facial and trigeminal neuropathy after stereotactic radiosurgery of vestibular schwannomas with marginal doses of 16-20 Gy, assessed whether proton beam radiosurgery using a marginal dose of only 12 Gy could control vestibular schwannomas while causing less neuropathy. Methods and Materials: Sixty-eight patients (mean age 67 years) were treated between 1992 and 1998. The mean tumor volume was 2.49 cm 3 . The dose to the tumor margin (70% isodose line) was 12 Gy. The prospectively specified follow-up consisted of neurologic evaluation and MRI at 6, 12, 24, and 36 months. Results: After a mean clinical follow-up of 44 months and imaging follow-up of 34 months in 64 patients, 35 tumors (54.7%) were smaller and 25 (39.1%) were unchanged (tumor control rate 94%; actuarial control rate 94% at 2 years and 84% at 5 years). Three tumors enlarged: one shrank after repeated radiosurgery, one remained enlarged at the time of unrelated death, and one had not been imaged for 4 years in a patient who remained asymptomatic at last follow-up. Intratumoral hemorrhage into one stable tumor required craniotomy that proved successful. Thus, 97% of tumors required no additional treatment. Three patients (4.7%) underwent shunting for hydrocephalus evident as increased ataxia. Of 6 patients with functional hearing ipsilaterally, 1 improved, 1 was unchanged, and 4 progressively lost hearing. Cranial neuropathies were infrequent: persistent facial hypesthesia (2 new, 1 exacerbated; 4.7%); intermittent facial paresthesias (5 new, 1 exacerbated; 9.4%); persistent facial weakness (2 new, 1 exacerbated; 4.7%) requiring oculoplasty; transient partial facial weakness (5 new, 1 exacerbated; 9.4%), and synkinesis (5 new, 1 exacerbated; 9.4%). Conclusion: Proton beam stereotactic radiosurgery of vestibular schwannomas at the

  15. Radiosurgery in gliomas (middle-line tumors)

    International Nuclear Information System (INIS)

    Betti, O.O.; Rosler, R.

    1989-01-01

    The clinical experience is presented obtained from treatment with high-energy linac radiosurgery of 22 patients with stereotactically biopsed gliomas located in middle-line, from thalamus to brain stem and from infundibulum to pineo-tectal regions, during the period 1982-1987. (H.W.). 10 refs

  16. Stereotactic Radiosurgery in the Management of Brain Metastases: An Institutional Retrospective Analysis of Survival

    International Nuclear Information System (INIS)

    Frazier, James L.; Batra, Sachin; Kapor, Sumit; Vellimana, Ananth; Gandhi, Rahul; Carson, Kathryn A.; Shokek, Ori; Lim, Michael; Kleinberg, Lawrence; Rigamonti, Daniele

    2010-01-01

    Purpose: The objective of this study was to report our experience with stereotactic radiosurgery performed with the Gamma Knife (GK) in the treatment of patients with brain metastases and to compare survival for those treated with radiosurgery alone with survival for those treated with radiosurgery and whole-brain radiotherapy. Methods and Materials: Prospectively collected demographic and clinical characteristics and treatment and survival data on 237 patients with intracranial metastases who underwent radiosurgery with the GK between 2003 and 2007 were reviewed. Kaplan-Meier and Cox proportional hazards regression analyses were used to compare survival by demographic and clinical characteristics and treatment. Results: The mean age of the patient population was 56 years. The most common tumor histologies were non-small-cell lung carcinoma (34.2%) and breast cancer (13.9%). The median overall survival time was 8.5 months from the time of treatment. The median survival times for patients with one, two/three, and four or more brain metastases were 8.5, 9.4, and 6.7 months, respectively. Patients aged 65 years or greater and those aged less than 65 years had median survival times of 7.8 and 9 months, respectively (p = 0.008). The Karnofsky Performance Score (KPS) at the time of treatment was a significant predictor of survival: those patients with a KPS of 70 or less had a median survival of 2.9 months compared with 10.3 months (p = 0.034) for those with a KPS of 80 or greater. There was no statistically significant difference in survival between patients treated with radiosurgery alone and those treated with radiosurgery plus whole-brain radiotherapy. Conclusions: Radiosurgery with the GK is an efficacious treatment modality for brain metastases. A KPS greater than 70, histology of breast cancer, smaller tumor volume, and age less than 65 years were associated with a longer median survival in our study.

  17. Management of vestibular schwannomas with linear accelerator-based stereotactic radiosurgery: a single center experience.

    Science.gov (United States)

    Sager, Omer; Beyzadeoglu, Murat; Dincoglan, Ferrat; Demiral, Selcuk; Uysal, Bora; Gamsiz, Hakan; Oysul, Kaan; Dirican, Bahar; Sirin, Sait

    2013-01-01

    The primary goal of treatment for vestibular schwannoma is to achieve local control without comprimising regional cranial nerve function. Stereotactic radiosurgery has emerged as a viable therapeutic option for vestibular schwannoma. The aim of the study is to report our 15-year single center experience using linear accelerator-based stereotactic radiosurgery in the management of patients with vestibular schwannoma. Between July 1998 and January 2013, 68 patients with unilateral vestibular schwannoma were treated using stereotactic radiosurgery at the Department of Radiation Oncology, Gulhane Military Medical Academy. All patients underwent high-precision stereotactic radiosurgery using a linear accelerator with 6-MV photons. Median follow-up time was 51 months (range, 9-107). Median age was 45 years (range, 20-77). Median dose was 12 Gy (range, 10-13) prescribed to the 85%-95% isodose line encompassing the target volume. Local tumor control in patients with periodic follow-up imaging was 96.1%. Overall hearing preservation rate was 76.5%. Linear accelerator-based stereotactic radiosurgery offers a safe and effective treatment for patients with vestibular schwannoma by providing high local control rates along with improved quality of life through well-preserved hearing function.

  18. Histopathological findings after Leksell gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Langmann, G.; Dexel, A.; Haller-Schober, E.M.; Koelli, H.; Kleinert, R.

    2002-01-01

    Radiosurgery for uveal melanoma can achieve tumor control according to clinical studies, yet histopathological proof has not been described. 8 eyes after radiosurgery which had to be removed either to regression failure or severe complications like neovascular glaucoma or persisting retinal detachment were investigated histopathologically and compared to 10 uveal melanomas that were treated by enucleation alone. Uveal melanomas treated with the gamma knife showed tumor necrosis (in more than 50 % total necrosis), a higher number of balloon cells, less number of mitoses and vascular changes (thickening of the vessel's walls, obliteration, thrombosis) which could not be demonstrated in enucleated eyes without irradiation. Leksell gamma knife can cause tumor necrosis and varying degrees of cell death and reduced reproducibility. Vascular changes seem to play a major role in tumor regression. (author)

  19. Cyst formation after radiosurgery for brain arteriovenous malformation treated with cystoperitoneal shunt

    International Nuclear Information System (INIS)

    Morihiro, Yusuke; Kato, Syoichi; Imoto, Hirochika

    2010-01-01

    Gamma knife and CyberKnife radiosurgery are well established and less invasive treatments for arteriovenous malformation. Delayed cyst formation is a rare but well-known complication of radiosurgery for arteriovenous malformations. The optimal treatment of cysts forming after radiosurgery remains debatable. We present a case of cyst formation after radiosurgery for brain arteriovenous malformation that was treated with a cystoperitoneal shunt (C-P shunt). A 36-year-old woman presented with left hemiparesis and numbness. Computed tomography (CT) revealed intracranial hemorrhage in the right basal ganglia. Digital subtraction angiography revealed arteriovenous malformation in the brain. Intravascular embolization was performed three times and radiosurgery was performed twice, whereby complete obliteration of the nidus was achieved. Six and a half years later, routine follow-up magnetic resonance imaging revealed cyst formation, and the patient gradually developed left hemiparesis. First, we performed stereotactic cyst aspiration. This initially resulted in a reduction in the size of the cyst and disappearance of left hemiparesis, but within a short time, the cyst increased in size again and there was recurrence of hemiparesis. Therefore, an Ommaya reservoir was established; aspiration of the cyst through this reservoir brought about an initial reduction in cyst size and alleviation of symptoms; however, no further reduction in cyst size or improvement in symptoms could be achieved. Twenty months after the placement of the Ommaya reservoir, we performed a C-P shunt operation. After the operation, further reduction in the cyst size and complete symptomatic recovery were observed. (author)

  20. Applications of the parallel computing system using network

    International Nuclear Information System (INIS)

    Ido, Shunji; Hasebe, Hiroki

    1994-01-01

    Parallel programming is applied to multiple processors connected in Ethernet. Data exchanges between tasks located in each processing element are realized by two ways. One is socket which is standard library on recent UNIX operating systems. Another is a network connecting software, named as Parallel Virtual Machine (PVM) which is a free software developed by ORNL, to use many workstations connected to network as a parallel computer. This paper discusses the availability of parallel computing using network and UNIX workstations and comparison between specialized parallel systems (Transputer and iPSC/860) in a Monte Carlo simulation which generally shows high parallelization ratio. (author)

  1. Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter

    Czech Academy of Sciences Publication Activity Database

    Novotný ml., J.; Spěváček, V.; Hrbáček, J.; Judas, L.; Novotný, J.; Dvořák, P.; Tlacháčová, D.; Schmitt, M.; Tintěra, J.; Vymazal, J.; Čechák, T.; Michálek, Jiří; Přádný, Martin; Liščák, R.

    2004-01-01

    Roč. 5, - (2004), s. 225-235 ISSN 1024-2651. [International Stereotactic Radiosurgery Society Meeting /6./. Kyoto, 22.06.2003-26.06.2003] R&D Projects: GA MZd NC7460 Institutional research plan: CEZ:AV0Z4050913 Keywords : stereotactic radiosurgery * polymer-gel dosimeter Subject RIV: FD - Oncology ; Hematology

  2. Report of AAPM TG 135: quality assurance for robotic radiosurgery.

    Science.gov (United States)

    Dieterich, Sonja; Cavedon, Carlo; Chuang, Cynthia F; Cohen, Alan B; Garrett, Jeffrey A; Lee, Charles L; Lowenstein, Jessica R; d'Souza, Maximian F; Taylor, David D; Wu, Xiaodong; Yu, Cheng

    2011-06-01

    The task group (TG) for quality assurance for robotic radiosurgery was formed by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance (QA) Subcommittee. The task group (TG-135) had three main charges: (1) To make recommendations on a code of practice for Robotic Radiosurgery QA; (2) To make recommendations on quality assurance and dosimetric verification techniques, especially in regard to real-time respiratory motion tracking software; (3) To make recommendations on issues which require further research and development. This report provides a general functional overview of the only clinically implemented robotic radiosurgery device, the CyberKnife. This report includes sections on device components and their individual component QA recommendations, followed by a section on the QA requirements for integrated systems. Examples of checklists for daily, monthly, annual, and upgrade QA are given as guidance for medical physicists. Areas in which QA procedures are still under development are discussed.

  3. Clinical outcomes of gamma knife radiosurgery in the salvage treatment of patients with recurrent high-grade glioma.

    Science.gov (United States)

    Elaimy, Ameer L; Mackay, Alexander R; Lamoreaux, Wayne T; Demakas, John J; Fairbanks, Robert K; Cooke, Barton S; Lamm, Andrew F; Lee, Christopher M

    2013-12-01

    Previously published randomized evidence did not report a survival advantage for patients diagnosed with grade IV glioma who were treated with stereotactic radiosurgery followed by external beam radiation therapy and chemotherapy when compared to patients treated with external beam radiation therapy and chemotherapy alone. In recent years, gamma knife radiosurgery has become increasingly popular as a salvage treatment modality for patients diagnosed with recurrent high-grade glioma. The purpose of this article is to review the efficacy of gamma knife radiosurgery for patients who suffer from this malignancy. Retrospective, prospective, and randomized clinical studies published between the years 2000 and 2012 analyzing gamma knife radiosurgery for patients with high-grade glioma were reviewed. After assessing patient age, Karnofsky performance status, tumor histology, and extent of resection, gamma knife radiosurgery is a viable, minimally invasive treatment option for patients diagnosed with recurrent high-grade glioma. The available prospective and retrospective evidence suggests that gamma knife radiosurgery provides patients with a high local tumor control rate and a median survival after tumor recurrence ranging from 13 to 26 months. Gamma knife radiosurgery followed by chemotherapy for recurrent high-grade glioma may provide select patients with increased levels of survival. However, further investigation into this matter is needed due to the limited number of published reports. Additional clinical research is also needed to analyze the efficacy and radiation-related toxicities of fractionated gamma knife radiosurgery due to its potential to limit treatment-associated morbidity. Gamma knife radiosurgery is a safe and effective treatment option for select patients diagnosed with recurrent high-grade glioma. Although treatment outcomes have improved, further evidence in the form of phase III randomized trials is needed to assess the durability of treating

  4. Monte Carlo Techniques for Nuclear Systems - Theory Lectures

    International Nuclear Information System (INIS)

    Brown, Forrest B.; Univ. of New Mexico, Albuquerque, NM

    2016-01-01

    These are lecture notes for a Monte Carlo class given at the University of New Mexico. The following topics are covered: course information; nuclear eng. review & MC; random numbers and sampling; computational geometry; collision physics; tallies and statistics; eigenvalue calculations I; eigenvalue calculations II; eigenvalue calculations III; variance reduction; parallel Monte Carlo; parameter studies; fission matrix and higher eigenmodes; doppler broadening; Monte Carlo depletion; HTGR modeling; coupled MC and T/H calculations; fission energy deposition. Solving particle transport problems with the Monte Carlo method is simple - just simulate the particle behavior. The devil is in the details, however. These lectures provide a balanced approach to the theory and practice of Monte Carlo simulation codes. The first lectures provide an overview of Monte Carlo simulation methods, covering the transport equation, random sampling, computational geometry, collision physics, and statistics. The next lectures focus on the state-of-the-art in Monte Carlo criticality simulations, covering the theory of eigenvalue calculations, convergence analysis, dominance ratio calculations, bias in Keff and tallies, bias in uncertainties, a case study of a realistic calculation, and Wielandt acceleration techniques. The remaining lectures cover advanced topics, including HTGR modeling and stochastic geometry, temperature dependence, fission energy deposition, depletion calculations, parallel calculations, and parameter studies. This portion of the class focuses on using MCNP to perform criticality calculations for reactor physics and criticality safety applications. It is an intermediate level class, intended for those with at least some familiarity with MCNP. Class examples provide hands-on experience at running the code, plotting both geometry and results, and understanding the code output. The class includes lectures & hands-on computer use for a variety of Monte Carlo calculations

  5. Monte Carlo Techniques for Nuclear Systems - Theory Lectures

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Forrest B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Monte Carlo Methods, Codes, and Applications Group; Univ. of New Mexico, Albuquerque, NM (United States). Nuclear Engineering Dept.

    2016-11-29

    These are lecture notes for a Monte Carlo class given at the University of New Mexico. The following topics are covered: course information; nuclear eng. review & MC; random numbers and sampling; computational geometry; collision physics; tallies and statistics; eigenvalue calculations I; eigenvalue calculations II; eigenvalue calculations III; variance reduction; parallel Monte Carlo; parameter studies; fission matrix and higher eigenmodes; doppler broadening; Monte Carlo depletion; HTGR modeling; coupled MC and T/H calculations; fission energy deposition. Solving particle transport problems with the Monte Carlo method is simple - just simulate the particle behavior. The devil is in the details, however. These lectures provide a balanced approach to the theory and practice of Monte Carlo simulation codes. The first lectures provide an overview of Monte Carlo simulation methods, covering the transport equation, random sampling, computational geometry, collision physics, and statistics. The next lectures focus on the state-of-the-art in Monte Carlo criticality simulations, covering the theory of eigenvalue calculations, convergence analysis, dominance ratio calculations, bias in Keff and tallies, bias in uncertainties, a case study of a realistic calculation, and Wielandt acceleration techniques. The remaining lectures cover advanced topics, including HTGR modeling and stochastic geometry, temperature dependence, fission energy deposition, depletion calculations, parallel calculations, and parameter studies. This portion of the class focuses on using MCNP to perform criticality calculations for reactor physics and criticality safety applications. It is an intermediate level class, intended for those with at least some familiarity with MCNP. Class examples provide hands-on experience at running the code, plotting both geometry and results, and understanding the code output. The class includes lectures & hands-on computer use for a variety of Monte Carlo calculations

  6. Monte Carlo simulations on SIMD computer architectures

    International Nuclear Information System (INIS)

    Burmester, C.P.; Gronsky, R.; Wille, L.T.

    1992-01-01

    In this paper algorithmic considerations regarding the implementation of various materials science applications of the Monte Carlo technique to single instruction multiple data (SIMD) computer architectures are presented. In particular, implementation of the Ising model with nearest, next nearest, and long range screened Coulomb interactions on the SIMD architecture MasPar MP-1 (DEC mpp-12000) series of massively parallel computers is demonstrated. Methods of code development which optimize processor array use and minimize inter-processor communication are presented including lattice partitioning and the use of processor array spanning tree structures for data reduction. Both geometric and algorithmic parallel approaches are utilized. Benchmarks in terms of Monte Carl updates per second for the MasPar architecture are presented and compared to values reported in the literature from comparable studies on other architectures

  7. Lattice gauge theory using parallel processors

    International Nuclear Information System (INIS)

    Lee, T.D.; Chou, K.C.; Zichichi, A.

    1987-01-01

    The book's contents include: Lattice Gauge Theory Lectures: Introduction and Current Fermion Simulations; Monte Carlo Algorithms for Lattice Gauge Theory; Specialized Computers for Lattice Gauge Theory; Lattice Gauge Theory at Finite Temperature: A Monte Carlo Study; Computational Method - An Elementary Introduction to the Langevin Equation, Present Status of Numerical Quantum Chromodynamics; Random Lattice Field Theory; The GF11 Processor and Compiler; and The APE Computer and First Physics Results; Columbia Supercomputer Project: Parallel Supercomputer for Lattice QCD; Statistical and Systematic Errors in Numerical Simulations; Monte Carlo Simulation for LGT and Programming Techniques on the Columbia Supercomputer; Food for Thought: Five Lectures on Lattice Gauge Theory

  8. Outcomes of Diffusion Tensor Tractography-Integrated Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Tomoyuki, E-mail: kouga-tky@umin.ac.jp [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Maruyama, Keisuke; Kamada, Kyousuke; Ota, Takahiro; Shin, Masahiro [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Itoh, Daisuke [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Kunii, Naoto [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Ino, Kenji; Terahara, Atsuro; Aoki, Shigeki; Masutani, Yoshitaka [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Saito, Nobuhito [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan)

    2012-02-01

    Purpose: To analyze the effect of use of tractography of the critical brain white matter fibers created from diffusion tensor magnetic resonance imaging on reduction of morbidity associated with radiosurgery. Methods and Materials: Tractography of the pyramidal tract has been integrated since February 2004 if lesions are adjacent to it, the optic radiation since May 2006, and the arcuate fasciculus since October 2007. By visually confirming the precise location of these fibers, the dose to these fiber tracts was optimized. One hundred forty-four consecutive patients with cerebral arteriovenous malformations who underwent radiosurgery with this technique between February 2004 and December 2009 were analyzed. Results: Tractography was prospectively integrated in 71 of 155 treatments for 144 patients. The pyramidal tract was visualized in 45, the optic radiation in 22, and the arcuate fasciculus in 13 (two tracts in 9). During the follow-up period of 3 to 72 months (median, 23 months) after the procedure, 1 patient showed permanent worsening of pre-existing dysesthesia, and another patient exhibited mild transient hemiparesis 12 months later but fully recovered after oral administration of corticosteroid agents. Two patients had transient speech disturbance before starting integration of the arcuate fasciculus tractography, but no patient thereafter. Conclusion: Integrating tractography helped prevent morbidity of radiosurgery in patients with brain arteriovenous malformations.

  9. Stereotactic gamma radiosurgery of pineal and related tumors

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yoshimasa; Yamada, Yasushi; Kida, Yoshihisa

    2001-01-01

    The role of gamma radiosurgery as an additional therapy after conventional treatments for pineal and related tumors was studied in 30 out of 33 cases with a mean follow-up of 23.3 months. Overall results showed that complete response (CR) was obtained in 8 cases (26.7%) and response rate was 73.3%. However, enlargement of the tumors was noted in 8 cases, of which 7 (23.3%) died of tumor progression (PG). Germinomas and pineocytomas showed higher response and control rates of 100%, and no tumor enlargement or death occurred after gamma knife treatment. In germinoma with STGC (syncytiotrophoblastic giant cell) which has been thought to have intermediate prognosis, two cases showed partial response (PR), but another died from progression of the disease. Malignant germ cell tumors and pineoblastomas showed unfavorable response and prognosis; the response and progression rates were 50%. However, complete response was obtained in 3 cases (25%) after gamma radiosurgery. Gamma knife was the initial treatment in three cases without pathological diagnosis in which one obtained CR and two showed partial response (PR). Stereotactic gamma radiosurgery is expected to be an effective and novel treatment for pineal and related tumors not only as an adjuvant, but also as an initial therapy. (author)

  10. Effects of gamma knife radiosurgery for pediatric craniopharyngiomas

    International Nuclear Information System (INIS)

    Tanaka, Takayuki; Kobayashi, Tatsuya; Kida, Yoshihisa

    1996-01-01

    Seven cases of pediatric craniopharyngiomas have been treated by gamma knife and followed-up for a mean 24.1 months between May, 1991 and March, 1995. They included 4 boys and 3 girls with a mean age of 8.9 years. Initial signs and symptoms were: headaches in 2 cases, decrease in visual acuity in 6 cases, visual field deficit in 5 cases, hypopituitary function in 5 cases, and diabetes insipidus in one case. Prior to the radiosurgery, surgical therapy had been performed in 7 cases, conventional radiotherapy in one case, and chemotherapy in one case. Tumor were located in the chiasmal region in 3 cases and the suprasellar region in 4 cases. Mean tumor diameter was 18.5 mm. Mean and marginal irradiation dosages were 25.9 Gy and 13.4 Gy. Repeated MRI indicated marked shrinkage of tumors was obtained in all 7 cases. Follow up showed neurological signs and symptoms improved in 3 cases and remained unchanged in 4 cases, without any side-effects. Hormonal study indicated TSH decreased about one year after gamma knife radiosurgery. It is considered that gamma knife radiosurgery will be a safe and effective treatment for pediatric craniopharyngiomas in combination with microsurgery. (author)

  11. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  12. TU-F-CAMPUS-T-02: Monte Carlo Evaluation of Kilovoltage Radiosurgery with AuNPs for Age Related Macular Degeneration (AMD)

    International Nuclear Information System (INIS)

    Brivio, D; Zygmanski, P; Sajo, E; Makrigiorgos, G; Ngwa, W

    2015-01-01

    Purpose: To evaluate the benefit of gold nanoparticles (AuNP) in radiosurgery of Age related Macular Degeneration (AMD) using Monte Carlo (MC) simulation. AMD disease causes vision loss due to a leaky vasculature of the endothelial cells. Radiosurgical therapy aims to destroy this vasculature while minimizing the delivered dose to healthy tissues of the eye. AuNP known to enhance local dose have been targeted to the macular choroidal endothelial cells to increase the therapeutic efficacy. Methods: Dose enhancement ratio (DER) in macula endothelial cells due to a thin layer of AuNP has been calculated by a MC radiation transport simulation. AuNP layer (10–100nm) has been placed on the bottom of the macula at 2.4cm depth in a water parallelepiped 3×3×6cm3. This layer has been modeled considering various concentrations of AuNP ranging from 5.5–200mg per gram of endothelial cell (volume 10×10×2um3). The x-ray source is 100kVp 4mm diameter beam tilted 0°-30° with respect to the lens. Results: DER in endothelial cell for AuNP concentration of 31mg/g (shown experimentally feasible) and 10–100nm sizes is about 1.8. Tilting 4mm-beam does not reduce the enhancement but allows to avoid the surrounding tissues. Dose distribution in the AuNP vicinity has a significant increase within 30um, peaked at AuNP interface. DER inside and outside of the irradiation 4mm-field are the same while the actual delivered dose is more than one order of magnitude lower outside the field. Compared to 100kVp, usage of filtered spectra with enhanced flux in the region 20keV-40keV shows further increase of DER by about 20%. Dose to the neighboring organs such as retina/optic nerve are reduced accordingly. Conclusion: The results of this MC simulation provide further confirmation of the potential to enhance DER with AuNP from previous analytical calculations. This study provides impetus to improve treatment effectiveness of AMD disease with radiotherapy

  13. TU-F-CAMPUS-T-02: Monte Carlo Evaluation of Kilovoltage Radiosurgery with AuNPs for Age Related Macular Degeneration (AMD)

    Energy Technology Data Exchange (ETDEWEB)

    Brivio, D; Zygmanski, P [Brigham & Women’s Hospital, Boston, MA (United States); Sajo, E [Univ Massachusetts Lowell, Lowell, MA (United States); Makrigiorgos, G [Dana Farber Cancer Institute, Boston, MA (United States); Ngwa, W [Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To evaluate the benefit of gold nanoparticles (AuNP) in radiosurgery of Age related Macular Degeneration (AMD) using Monte Carlo (MC) simulation. AMD disease causes vision loss due to a leaky vasculature of the endothelial cells. Radiosurgical therapy aims to destroy this vasculature while minimizing the delivered dose to healthy tissues of the eye. AuNP known to enhance local dose have been targeted to the macular choroidal endothelial cells to increase the therapeutic efficacy. Methods: Dose enhancement ratio (DER) in macula endothelial cells due to a thin layer of AuNP has been calculated by a MC radiation transport simulation. AuNP layer (10–100nm) has been placed on the bottom of the macula at 2.4cm depth in a water parallelepiped 3×3×6cm3. This layer has been modeled considering various concentrations of AuNP ranging from 5.5–200mg per gram of endothelial cell (volume 10×10×2um3). The x-ray source is 100kVp 4mm diameter beam tilted 0°-30° with respect to the lens. Results: DER in endothelial cell for AuNP concentration of 31mg/g (shown experimentally feasible) and 10–100nm sizes is about 1.8. Tilting 4mm-beam does not reduce the enhancement but allows to avoid the surrounding tissues. Dose distribution in the AuNP vicinity has a significant increase within 30um, peaked at AuNP interface. DER inside and outside of the irradiation 4mm-field are the same while the actual delivered dose is more than one order of magnitude lower outside the field. Compared to 100kVp, usage of filtered spectra with enhanced flux in the region 20keV-40keV shows further increase of DER by about 20%. Dose to the neighboring organs such as retina/optic nerve are reduced accordingly. Conclusion: The results of this MC simulation provide further confirmation of the potential to enhance DER with AuNP from previous analytical calculations. This study provides impetus to improve treatment effectiveness of AMD disease with radiotherapy.

  14. Parallelizing an electron transport Monte Carlo simulator (MOCASIN 2.0)

    International Nuclear Information System (INIS)

    Schwetman, H.; Burdick, S.

    1988-01-01

    Electron transport simulators are tools for studying electrical properties of semiconducting materials and devices. As demands for modeling more complex devices and new materials have emerged, so have demands for more processing power. This paper documents a project to convert an electron transport simulator (MOCASIN 2.0) to a parallel processing environment. In addition to describing the conversion, the paper presents PPL, a parallel programming version of C running on a Sequent multiprocessor system. In timing tests, models that simulated the movement of 2,000 particles for 100 time steps were executed on ten processors, with a parallel efficiency of over 97%

  15. Parallelization of MCNP4 code by using simple FORTRAN algorithms

    International Nuclear Information System (INIS)

    Yazid, P.I.; Takano, Makoto; Masukawa, Fumihiro; Naito, Yoshitaka.

    1993-12-01

    Simple FORTRAN algorithms, that rely only on open, close, read and write statements, together with disk files and some UNIX commands have been applied to parallelization of MCNP4. The code, named MCNPNFS, maintains almost all capabilities of MCNP4 in solving shielding problems. It is able to perform parallel computing on a set of any UNIX workstations connected by a network, regardless of the heterogeneity in hardware system, provided that all processors produce a binary file in the same format. Further, it is confirmed that MCNPNFS can be executed also on Monte-4 vector-parallel computer. MCNPNFS has been tested intensively by executing 5 photon-neutron benchmark problems, a spent fuel cask problem and 17 sample problems included in the original code package of MCNP4. Three different workstations, connected by a network, have been used to execute MCNPNFS in parallel. By measuring CPU time, the parallel efficiency is determined to be 58% to 99% and 86% in average. On Monte-4, MCNPNFS has been executed using 4 processors concurrently and has achieved the parallel efficiency of 79% in average. (author)

  16. CloudMC: a cloud computing application for Monte Carlo simulation

    International Nuclear Information System (INIS)

    Miras, H; Jiménez, R; Miras, C; Gomà, C

    2013-01-01

    This work presents CloudMC, a cloud computing application—developed in Windows Azure®, the platform of the Microsoft® cloud—for the parallelization of Monte Carlo simulations in a dynamic virtual cluster. CloudMC is a web application designed to be independent of the Monte Carlo code in which the simulations are based—the simulations just need to be of the form: input files → executable → output files. To study the performance of CloudMC in Windows Azure®, Monte Carlo simulations with penelope were performed on different instance (virtual machine) sizes, and for different number of instances. The instance size was found to have no effect on the simulation runtime. It was also found that the decrease in time with the number of instances followed Amdahl's law, with a slight deviation due to the increase in the fraction of non-parallelizable time with increasing number of instances. A simulation that would have required 30 h of CPU on a single instance was completed in 48.6 min when executed on 64 instances in parallel (speedup of 37 ×). Furthermore, the use of cloud computing for parallel computing offers some advantages over conventional clusters: high accessibility, scalability and pay per usage. Therefore, it is strongly believed that cloud computing will play an important role in making Monte Carlo dose calculation a reality in future clinical practice. (note)

  17. CloudMC: a cloud computing application for Monte Carlo simulation.

    Science.gov (United States)

    Miras, H; Jiménez, R; Miras, C; Gomà, C

    2013-04-21

    This work presents CloudMC, a cloud computing application-developed in Windows Azure®, the platform of the Microsoft® cloud-for the parallelization of Monte Carlo simulations in a dynamic virtual cluster. CloudMC is a web application designed to be independent of the Monte Carlo code in which the simulations are based-the simulations just need to be of the form: input files → executable → output files. To study the performance of CloudMC in Windows Azure®, Monte Carlo simulations with penelope were performed on different instance (virtual machine) sizes, and for different number of instances. The instance size was found to have no effect on the simulation runtime. It was also found that the decrease in time with the number of instances followed Amdahl's law, with a slight deviation due to the increase in the fraction of non-parallelizable time with increasing number of instances. A simulation that would have required 30 h of CPU on a single instance was completed in 48.6 min when executed on 64 instances in parallel (speedup of 37 ×). Furthermore, the use of cloud computing for parallel computing offers some advantages over conventional clusters: high accessibility, scalability and pay per usage. Therefore, it is strongly believed that cloud computing will play an important role in making Monte Carlo dose calculation a reality in future clinical practice.

  18. Fractionated radiosurgery for 9L gliosarcoma in the rat brain

    International Nuclear Information System (INIS)

    Kim, Jae Ho; Khil, Mark S.; Kolozsvary, Andrew; Gutierrez, Jorge A.; Brown, Stephen L.

    1999-01-01

    Purpose: Fractionated radiosurgery is being carried out in the clinic to improve the therapeutic ratio of single-dose radiosurgery using various fractionation schemes. Because there is a paucity of experimental radiobiological data in the literature on the tumor response and late-responding normal tissue of critical intracranial structures to radiosurgery, the present animal study was designed to compare the response following a single high dose of radiation with that obtained from calculated fractionated doses of radiosurgery. Methods and Materials: Male Fischer rats with 9L gliosarcoma growing in their brains were stereotactically irradiated and assayed for the tumor control rate and brain tissue damage. The radiation dose needed for 50% tumor control (TCD 50 ) was used as the endpoint of the efficacy of radiosurgery. Normal brain damage was measured histologically following a period of time over 270 days. Histological evaluation included hematoxylin-eosin (H and E), Luxol fast blue and periodic acid Schiff (LFB/PAS) for the presence of myelin and glial fibrillary acidic protein (GFAP) for the assessment of astrocytic re-activity. The optical density of optic nerves and chiasms staining with LFB/PAS was quantitatively measured using a computer image analysis to assess the magnitude of demyelination. Results: Radiosurgery (RS) was found to be more effective in curing small tumors than large tumors. The dose required to control 50% of the tumored animals for 120 days was 24, 31, and 40 Gy for 2-, 6-, and 12-day-old tumors, respectively. Using 12-day-old brain tumors, two fractions of 23.5 Gy and three fractions of 18.5 Gy were found to be equivalent to the single dose of 35 Gy for tumor control. For normal brain damages, the visual pathways including optic nerves and chiasm were found to be highly radiosensitive structures. A single dose of 35 Gy produced 100% severe optic neuropathy. The fractionated RS regimens spared substantial optic nerve damage. Conclusion

  19. Radiosurgery of epidermoid tumors with gamma knife. Possiblity of radiosurgical nerve decompression

    International Nuclear Information System (INIS)

    Kida, Yoshihisa; Yoshimoto, Masayuki; Hasegawa, Toshinori; Fujitani, Shigeru

    2006-01-01

    Long-term results of radiosurgery for epidermoid tumors are reported. There are 7 cases including 2 males and 5 females, ages ranging from 6 to 46 (mean: 33.3 years). At radiosurgery whole tumor was covered in 4 cases and partially covered in 3 cases in attempting to relieve cranial nerve signs like trigeminal neuralgia and facial spasm. The mean maximum and marginal doses were 25.6 Gy and 14.6 Gy respectively. In the mean follow-up of 52.7 months, all the tumors showed good tumor control without any progression and tumor shrinkage has been confirmed in 2 out of the 7 cases. Symptomatic trigeminal neuralgia improved or disappeared in all 4 cases and facial spasm disappeared in one. No neurological deterioration was found in any of the cases after the treatment. In conclusion, it is apparent that epidermoid tumors do respond well to radiosurgery and the accompanying hyperactive dysfunction of cranial nerves is significantly improved by gamma knife treatment with either entire or partial tumor coverage. Therefore the radiosurgical nerve decompression for epidermoid tumor seems to be achieved by gamma-radiosurgery. (author)

  20. Resampling: An optimization method for inverse planning in robotic radiosurgery

    International Nuclear Information System (INIS)

    Schweikard, Achim; Schlaefer, Alexander; Adler, John R. Jr.

    2006-01-01

    By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design permits a large number of distinct beam directions to be used in one single treatment. These major technical differences provide an opportunity to improve upon the well-established principles for treatment planning used with GammaKnife or LINAC radiosurgery. With this objective in mind, our group has developed over the past decade an inverse planning tool for robotic radiosurgery. This system first computes a set of beam directions, and then during an optimization step, weights each individual beam. Optimization begins with a feasibility query, the answer to which is derived through linear programming. This approach offers the advantage of completeness and avoids local optima. Final beam selection is based on heuristics. In this report we present and evaluate a new strategy for utilizing the advantages of linear programming to improve beam selection. Starting from an initial solution, a heuristically determined set of beams is added to the optimization problem, while beams with zero weight are removed. This process is repeated to sample a set of beams much larger compared with typical optimization. Experimental results indicate that the planning approach efficiently finds acceptable plans and that resampling can further improve its efficiency

  1. Heterogeneous Hardware Parallelism Review of the IN2P3 2016 Computing School

    Science.gov (United States)

    Lafage, Vincent

    2017-11-01

    Parallel and hybrid Monte Carlo computation. The Monte Carlo method is the main workhorse for computation of particle physics observables. This paper provides an overview of various HPC technologies that can be used today: multicore (OpenMP, HPX), manycore (OpenCL). The rewrite of a twenty years old Fortran 77 Monte Carlo will illustrate the various programming paradigms in use beyond language implementation. The problem of parallel random number generator will be addressed. We will give a short report of the one week school dedicated to these recent approaches, that took place in École Polytechnique in May 2016.

  2. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    International Nuclear Information System (INIS)

    Ipsen, S.; Blanck, O.; Rades, D.; Oborn, B.; Bode, F.; Liney, G.; Hunold, P.; Schweikard, A.; Keall, P. J.

    2014-01-01

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  3. Radiotherapy beyond cancer: Target localization in real-time MRI and treatment planning for cardiac radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Ipsen, S. [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006, Australia and Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Blanck, O.; Rades, D. [Department of Radiation Oncology, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Oborn, B. [Illawarra Cancer Care Centre (ICCC), Wollongong, New South Wales 2500, Australia and Centre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, New South Wales 2500 (Australia); Bode, F. [Medical Department II, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Liney, G. [Ingham Institute for Applied Medical Research, Liverpool Hospital, Liverpool, New South Wales 2170 (Australia); Hunold, P. [Department of Radiology and Nuclear Medicine, University of Luebeck and University Medical Center Schleswig-Holstein, Campus Luebeck, Luebeck 23562 (Germany); Schweikard, A. [Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23562 (Germany); Keall, P. J., E-mail: paul.keall@sydney.edu.au [Radiation Physics Laboratory, Sydney Medical School, The University of Sydney, Sydney, New South Wales 2006 (Australia)

    2014-12-15

    Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. Methods: For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Results: Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior–inferior), 2.4 mm (anterior–posterior), and 2 mm (left–right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the

  4. Radiotherapy beyond cancer: target localization in real-time MRI and treatment planning for cardiac radiosurgery.

    Science.gov (United States)

    Ipsen, S; Blanck, O; Oborn, B; Bode, F; Liney, G; Hunold, P; Rades, D; Schweikard, A; Keall, P J

    2014-12-01

    Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world-wide. AFib is usually treated with minimally invasive, time consuming catheter ablation techniques. While recently noninvasive radiosurgery to the pulmonary vein antrum (PVA) in the left atrium has been proposed for AFib treatment, precise target location during treatment is challenging due to complex respiratory and cardiac motion. A MRI linear accelerator (MRI-Linac) could solve the problems of motion tracking and compensation using real-time image guidance. In this study, the authors quantified target motion ranges on cardiac magnetic resonance imaging (MRI) and analyzed the dosimetric benefits of margin reduction assuming real-time motion compensation was applied. For the imaging study, six human subjects underwent real-time cardiac MRI under free breathing. The target motion was analyzed retrospectively using a template matching algorithm. The planning study was conducted on a CT of an AFib patient with a centrally located esophagus undergoing catheter ablation, representing an ideal case for cardiac radiosurgery. The target definition was similar to the ablation lesions at the PVA created during catheter treatment. Safety margins of 0 mm (perfect tracking) to 8 mm (untracked respiratory motion) were added to the target, defining the planning target volume (PTV). For each margin, a 30 Gy single fraction IMRT plan was generated. Additionally, the influence of 1 and 3 T magnetic fields on the treatment beam delivery was simulated using Monte Carlo calculations to determine the dosimetric impact of MRI guidance for two different Linac positions. Real-time cardiac MRI showed mean respiratory target motion of 10.2 mm (superior-inferior), 2.4 mm (anterior-posterior), and 2 mm (left-right). The planning study showed that increasing safety margins to encompass untracked respiratory motion leads to overlapping structures even in the ideal scenario, compromising

  5. Gamma Knife® radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Yen, Chun-Po; Schlesinger, David; Sheehan, Jason P

    2011-11-01

    Trigeminal neuralgia is characterized by a temporary paroxysmal lancinating facial pain in the trigeminal nerve distribution. The prevalence is four to five per 100,000. Local pressure on nerve fibers from vascular loops results in painful afferent discharge from an injured segment of the fifth cranial nerve. Microvascular decompression addresses the underlying pathophysiology of the disease, making this treatment the gold standard for medically refractory trigeminal neuralgia. In patients who cannot tolerate a surgical procedure, those in whom a vascular etiology cannot be identified, or those unwilling to undergo an open surgery, stereotactic radiosurgery is an appropriate alternative. The majority of patients with typical facial pain will achieve relief following radiosurgical treatment. Long-term follow-up for recurrence as well as for radiation-induced complications is required in all patients undergoing stereotactic radiosurgery for trigeminal neuralgia.

  6. Long-term follow-up of patients with surgical intractable acromegaly after linear accelerator radiosurgery

    Directory of Open Access Journals (Sweden)

    Jiun-Lin Yan

    2013-07-01

    Conclusion: In comparison to other radiosurgery modalities, LINAC radiosurgery also provides a satisfactory outcome. SRS has maximum effect over the first 2 years and stabilizes after 7.5 years. Moreover, SRS elicits long-term biochemical effects and requires longer follow-up for better biochemical remission.

  7. Discrete Diffusion Monte Carlo for Electron Thermal Transport

    Science.gov (United States)

    Chenhall, Jeffrey; Cao, Duc; Wollaeger, Ryan; Moses, Gregory

    2014-10-01

    The iSNB (implicit Schurtz Nicolai Busquet electron thermal transport method of Cao et al. is adapted to a Discrete Diffusion Monte Carlo (DDMC) solution method for eventual inclusion in a hybrid IMC-DDMC (Implicit Monte Carlo) method. The hybrid method will combine the efficiency of a diffusion method in short mean free path regions with the accuracy of a transport method in long mean free path regions. The Monte Carlo nature of the approach allows the algorithm to be massively parallelized. Work to date on the iSNB-DDMC method will be presented. This work was supported by Sandia National Laboratory - Albuquerque.

  8. Stereotaxic radiosurgery for therapy of arterivenous malformation of the brain

    International Nuclear Information System (INIS)

    Beraha, J.; Feriancic, C.V.; Scaff, L.A.M.

    1987-01-01

    Since march 1983 we are attempting for the first time in Brazil to develop improvements on stereotactic radiosurgery techniques. We have been using the multifocal irradiation method attaching to this purpose the Barcia IV stereotactic frame to a 4 MV linear accelerator. We show details about the centralization technique and the security patterns in our system. From October 1983 to November 1986, 25 patients with arteriovenous malformations of the brain were submitted to a radiosurgery treatment in our service. Good results obtained on the follow-up from one to three years are analysed. (author)

  9. Tolerance of cranial nerves of the cavernous sinus to radiosurgery

    International Nuclear Information System (INIS)

    Tishler, R.B.; Loeffler, J.S.; Alexander, E. III; Kooy, H.M.; Lunsford, L.D.; Duma, C.; Flickinger, J.C.

    1993-01-01

    Stereotactic radiosurgery is becoming a more accepted treatment option for benign, deep seated intracranial lesions. However, little is known about the effects of large single fractions of radiation on cranial nerves. This study was undertaken to assess the effect of radiosurgery on the cranial nerves of the cavernous sinus. The authors examined the tolerance of cranial nerves (II-VI) following radiosurgery for 62 patients (42/62 with meningiomas) treated for lesions within or near the cavernous sinus. Twenty-nine patients were treated with a modified 6 MV linear accelerator (Joint Center for Radiation Therapy) and 33 were treated with the Gamma Knife (University of Pittsburgh). Three-dimensional treatment plans were retrospectively reviewed and maximum doses were calculated for the cavernous sinus and the optic nerve and chiasm. Median follow-up was 19 months (range 3-49). New cranial neuropathies developed in 12 patients from 3-41 months following radiosurgery. Four of these complications involved injury to the optic system and 8 (3/8 transient) were the result of injury to the sensory or motor nerves of the cavernous sinus. There was no clear relationship between the maximum dose to the cavernous sinus and the development of complications for cranial nerves III-VI over the dose range used (1000-4000 cGy). For the optic apparatus, there was a significantly increased incidence of complications with dose. Four of 17 patients (24%) receiving greater than 800 cGy to any part of the optic apparatus developed visual complications compared with 0/35 who received less than 800 cGy (p = 0.009). Radiosurgery using tumor-controlling doses of up to 4000 cGy appears to be a relatively safe technique in treating lesions within or near the sensory and motor nerves (III-VI) of the cavernous sinus. The dose to the optic apparatus should be limited to under 800 cGy. 21 refs., 4 tabs

  10. Large central lesions compressing the hypothalamus and brainstem. Operative approaches and combination treatment with radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Hiroshi K.; Negishi, Masatoshi; Kohga, Hideaki; Hirato, Masafumi; Ohye, Chihiro [Gunma Univ., Maebashi (Japan). School of Medicine; Shibazaki, Tohru

    1998-09-01

    A major aim of minimally invasive neurosurgery is to preserve function in the brain and cranial nerves. Based on previous results of radiosurgery for central lesions (19 craniopharyngiomas, 46 pituitary adenomas, 9 meningeal tumors), combined micro- and/or radiosurgery was applied for large lesions compressing the hypothalamus and/or brainstem. A basal interhemispheric approach via superomedial orbitotomy or a transcallosal-transforaminal approach was used for these large tumors. Tumors left behind in the hypothalamus or cavernous sinus were treated with radiosurgery using a gamma unit. Preoperative hypothalamo-pituitary functions were preserved in most of these patients. Radiosurgical results were evaluated in patients followed for more than 2 years after treatment. All 9 craniopharyngiomas decreased in size after radiosurgery, although a second treatment was required in 4 patients. All 20 pituitary adenomas were stable or decreased in size and 5 of 7 functioning adenomas showed normalized values of hormones in the serum. All 3 meningeal tumors were stable or decreased in size after treatment. No cavernous sinus symptoms developed after radiosurgery. We conclude that combined micro- and radio-neurosurgery is an effective and less invasive treatment for large central lesions compressing the hypothalamus and brainstem. (author)

  11. Large central lesions compressing the hypothalamus and brainstem. Operative approaches and combination treatment with radiosurgery

    International Nuclear Information System (INIS)

    Inoue, Hiroshi K.; Negishi, Masatoshi; Kohga, Hideaki; Hirato, Masafumi; Ohye, Chihiro; Shibazaki, Tohru

    1998-01-01

    A major aim of minimally invasive neurosurgery is to preserve function in the brain and cranial nerves. Based on previous results of radiosurgery for central lesions (19 craniopharyngiomas, 46 pituitary adenomas, 9 meningeal tumors), combined micro- and/or radiosurgery was applied for large lesions compressing the hypothalamus and/or brainstem. A basal interhemispheric approach via superomedial orbitotomy or a transcallosal-transforaminal approach was used for these large tumors. Tumors left behind in the hypothalamus or cavernous sinus were treated with radiosurgery using a gamma unit. Preoperative hypothalamo-pituitary functions were preserved in most of these patients. Radiosurgical results were evaluated in patients followed for more than 2 years after treatment. All 9 craniopharyngiomas decreased in size after radiosurgery, although a second treatment was required in 4 patients. All 20 pituitary adenomas were stable or decreased in size and 5 of 7 functioning adenomas showed normalized values of hormones in the serum. All 3 meningeal tumors were stable or decreased in size after treatment. No cavernous sinus symptoms developed after radiosurgery. We conclude that combined micro- and radio-neurosurgery is an effective and less invasive treatment for large central lesions compressing the hypothalamus and brainstem. (author)

  12. A multi-institutional analysis of complication outcomes after arteriovenous malformation radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Lunsford, L. Dade; Pollock, Bruce E.; Yamamoto, Masaaki; Gorman, Deborah A.; Schomberg, Paula J.; Sneed, Patricia; Larson, David; Smith, Vernon; McDermott, Michael W.; Miyawaki, Lloyd; Chilton, Jonathan; Morantz, Robert A.; Young, Byron; Jokura, Hidefumi; Liscak, Roman

    1999-01-01

    Purpose: To better understand radiation complications of arteriovenous malformation (AVM) radiosurgery and factors affecting their resolution. Methods and Materials: AVM patients (102/1255) who developed neurological sequelae after radiosurgery were studied. The median AVM marginal dose (D min ) was 19 Gy (range: 10-35). The median volume was 5.7 cc (range: 0.26-143). Median follow-up was 34 months (range: 9-140). Results: Complications consisted of 80/102 patients with evidence of radiation injury to the brain parenchyma (7 also with cranial nerve deficits, 12 also with seizures, 5 with cyst formation), 12/102 patients with isolated cranial neuropathies, and 10/102 patients with only new or worsened seizures. Severity was classified as minimal in 39 patients, mild in 40, disabling in 21, and fatal in 2 patients. Symptoms resolved completely in 42 patients for an actuarial resolution rate of 54% ± 7% at 3 years post-onset. Multivariate analysis identified significantly greater symptom resolution in patients with no prior history of hemorrhage (p = 0.01, 66% vs. 41%), and in patients with symptoms of minimal severity: headache or seizure as the only sequelae of radiosurgery (p < 0.0001, 88% vs. 34%). Conclusion: Late sequelae of radiosurgery manifest in varied ways. Further long-term studies of these problems are needed that take into account symptom severity and prior hemorrhage history

  13. The Physician Tendency in Stereotactic Radiosurgery Dose Prescription in Benign Intracranial Tumor at dr. Cipto Mangunkusumo National Hospital, Jakarta

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-09-01

    Full Text Available Stereotactic radiosurgery (SRS is one of the treatment modalities for benign intra-cranial tumor, especiallyfor the tumor located next to the critical neural structure. The prescribed dose for radiosurgery depends onthe maximal tumor diameter and surrounding normal tissue tolerance dose. This cross sectional study wasconducted to evaluate the physician’s tendency in radiosurgery dose prescription. We observed treatmentplanning data of 32 patients with benign intra-cranial tumor, which had been treated with SRS at Dr. CiptoMangunkusumo National Hospital in 2009-2010. The peripheral dose, organ at risk (OAR dose limitiationand maximum tumor diameter were recorded. We compared our SRS dose with dose limitation, whichallowed safer dosing based on maximal tumor diameter perspective and the nearest OAR dose constraint.From maximal tumor diameter perspective, we prescribed mean±SD radiosurgery doses, which were11.63±2.21Gy, 10.21±1.29Gy and 9.88±1.07Gy for the tumor size ≤2cm, 2.01-3cm and 3,01-4cm respectively.Our radiosurgery dose was the lowest than dose limitation based on the nearest OAR perspective, followedby maximal tumor diameter perspective. It was concluded that radiosurgery dose had the tendency to beinfluenced by surrounding healthy tissue tolerance rather than maximal tumor diameter. Keywords: stereotactic, radiosurgery, benign tumor, dose.   Kecenderungan Dokter dalam Menentukan Dosis StereotacticRadiosurgery untuk Tumor Jinak Intrakranial diRSUP Nasional dr. Cipto Mangunkusumo, Jakarta Abstrak Stereotactic radiosurgery (SRS merupakan salah satu modalitas pengobatan tumor jinak intra-kranialterutama untuk tumor yang berdekatan dengan struktur saraf penting. Penentuan dosis pada radiosurgerytergantung pada diameter tumor maksimal dan dosis toleransi jaringan sehat sekitarnya. Penelitian inidilakukan untuk mengevaluasi kecenderungan dokter dalam menentukan dosis radiosurgery. Penelitian crosssectional ini mengevaluasi data

  14. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  15. Technical and anatomical aspects of novalis stereotactic radiosurgery sphenopalatine ganglionectomy

    International Nuclear Information System (INIS)

    De Salles, Antonio A.F.; Gorgulho, Alessandra; Golish, S. Raymond Ph.D.; Medin, Paul M.; Malkasian, Dennis; Solberg, Timothy D.; Selch, Michael T.

    2006-01-01

    Background: Several techniques have been applied for destruction of the sphenopalatine ganglion to control cluster headache and ocular pain with sympathetic component. Cluster headache has responded to radiofrequency ablation or phenol destruction. Radiosurgery of the sphenopalatine ganglion is promising due to the excellent visualization of the target on magnetic resonance imaging (MRI), computed tomography (CT), and skull X-rays. Material and Methods: Six patients and one cadaver head were analyzed in this study. The cadaver-head dissection confirmed the location of the sphenopalatine ganglion on X-rays and CT imaging. One patient undergoing radiofrequency sphenopalatine ablation participated for confirmation of the location of the ganglion on plain X-rays. Five patients received radiosurgery of the sphenopalatine ganglion. One patient had classic unilateral cluster headache. Two patients had neuropathic pain and 1 had bilateral migrainous neuralgia. The fifth patient had bilateral atypical facial pain. All received a single maximal dose of 90 Gy with a 5- or 7.5-mm circular collimator. MRI, CT, and skull X-rays identified and confirmed the target. Results: The sphenopalatine fossa is seen in the skull X-ray as an inverse tear drop just caudal to the sphenoid sinus. This location is readily correlated to the CT target by the stereotactic coordinates and confirmed with the presence of the ganglion visualized in the MRI scan. Only the patient with cluster headache experienced lasting pain relief. Conclusion: Multiple imaging modalities confirmed the location of the sphenopalatine ganglion for radiosurgery. The procedure was performed safely with CT and MRI fusion. Radiosurgery was significantly beneficial only on classic cluster headache

  16. Bevacizumab for the Treatment of Gammaknife Radiosurgery-Induced Brain Radiation Necrosis.

    Science.gov (United States)

    Ma, Yifang; Zheng, Chutian; Feng, Yiping; Xu, Qingsheng

    2017-09-01

    Radiation necrosis is one of the complications of Gammaknife radiosurgery. The traditional treatment of radiation necrosis carries a high risk of failure, Bevacizumab is an antiangiogenic monoclonal antibody against vascular endothelial growth factor, a known mediator of cerebral edema. It can be used to successfully treat brain radiation necrosis. Two patients with a history of small cell lung cancer presented with metastatic disease to the brain. They underwent Gammaknife radiosurgery to brain metastases. Several months later, magnetic resonance imaging showed radiation necrosis with significant surrounding edema. The patients had a poor response to treatment with dexamethasone. They were eventually treated with bevacizumab (5 mg/kg every 2 weeks, 7.5 mg/kg every 3 weeks, respectively), and the treatment resulted in significant clinical and radiographic improvement. Bevacizumab can be successfully used to treat radiation necrosis induced by Gammaknife radiosurgery in patients with cerebral metastases. It is of particular benefit in patients with poor reaction to corticosteroids and other medications.

  17. Atlas-based functional radiosurgery: Early results

    Energy Technology Data Exchange (ETDEWEB)

    Stancanello, J.; Romanelli, P.; Pantelis, E.; Sebastiano, F.; Modugno, N. [Politecnico di Milano, Bioengineering Department and NEARlab, Milano, 20133 (Italy) and Siemens AG, Research and Clinical Collaborations, Erlangen, 91052 (Germany); Functional Neurosurgery Deptartment, Neuromed IRCCS, Pozzilli, 86077 (Italy); CyberKnife Center, Iatropolis, Athens, 15231 (Greece); Functional Neurosurgery Deptartment, Neuromed IRCCS, Pozzilli, 86077 (Italy)

    2009-02-15

    Functional disorders of the brain, such as dystonia and neuropathic pain, may respond poorly to medical therapy. Deep brain stimulation (DBS) of the globus pallidus pars interna (GPi) and the centromedian nucleus of the thalamus (CMN) may alleviate dystonia and neuropathic pain, respectively. A noninvasive alternative to DBS is radiosurgical ablation [internal pallidotomy (IP) and medial thalamotomy (MT)]. The main technical limitation of radiosurgery is that targets are selected only on the basis of MRI anatomy, without electrophysiological confirmation. This means that, to be feasible, image-based targeting must be highly accurate and reproducible. Here, we report on the feasibility of an atlas-based approach to targeting for functional radiosurgery. In this method, masks of the GPi, CMN, and medio-dorsal nucleus were nonrigidly registered to patients' T1-weighted MRI (T1w-MRI) and superimposed on patients' T2-weighted MRI (T2w-MRI). Radiosurgical targets were identified on the T2w-MRI registered to the planning CT by an expert functional neurosurgeon. To assess its feasibility, two patients were treated with the CyberKnife using this method of targeting; a patient with dystonia received an IP (120 Gy prescribed to the 65% isodose) and a patient with neuropathic pain received a MT (120 Gy to the 77% isodose). Six months after treatment, T2w-MRIs and contrast-enhanced T1w-MRIs showed edematous regions around the lesions; target placements were reevaluated by DW-MRIs. At 12 months post-treatment steroids for radiation-induced edema and medications for dystonia and neuropathic pain were suppressed. Both patients experienced significant relief from pain and dystonia-related problems. Fifteen months after treatment edema had disappeared. Thus, this work shows promising feasibility of atlas-based functional radiosurgery to improve patient condition. Further investigations are indicated for optimizing treatment dose.

  18. The usefulness of adjuvant therapy using gamma knife radiosurgery for the recurrent or residual nonfunctioning pituitary adenomas

    International Nuclear Information System (INIS)

    Iwai, Yoshiyasu; Yamanaka, Kazuhiro; Yoshioka, Katsunobu; Yoshimura, Masaki; Honda, Yuji; Matsusaka, Yasuhiro; Komiyama, Masaki; Yasui, Toshihiro

    2005-01-01

    We evaluated the treatment results of nonfunctioning pituitary adenomas in the era of radiosurgery. Between January 1994 and December 2003, we operated on 44 patients with nonfunctioning pituitary adenomas. Forty-three patients were operated on by transsphenoidal surgery and one patient was operated on by the transcranial approach. Total removal was able to be achieved in 13 patients (30%). Gamma knife radiosurgery was performed for residual tumor in 26 patients and for recurrence in 2 patients. The mean tumor diameter at the gamma knife radiosurgery was 18.2 mm (7.9 to 26.3 mm). The treatment dose was a mean of 12.3 Gy (8 to 16 Gy) to the tumor margin. The mean follow-up period after radiosurgery was 36.4 months. Tumor growth control was able to be achieved in 26 patients (93%). Two patients (7%) required adrenal and thyroid hormonal replacement during the follow-up period after radiosurgery due to radiation-induced endocrinopathy. None of the patients suffered from new cranial nerve deficits. This included optic neuropathy. Surgical resection using transsphenoidal surgery and subsequent gamma knife radiosurgery for residual and recurrent tumor proved to have a highly effective tumor growth control rate, and maintained the quality of life in patients with nonfunctioning pituitary adenomas. (author)

  19. A hybrid parallel framework for the cellular Potts model simulations

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi [Los Alamos National Laboratory; He, Kejing [SOUTH CHINA UNIV; Dong, Shoubin [SOUTH CHINA UNIV

    2009-01-01

    The Cellular Potts Model (CPM) has been widely used for biological simulations. However, most current implementations are either sequential or approximated, which can't be used for large scale complex 3D simulation. In this paper we present a hybrid parallel framework for CPM simulations. The time-consuming POE solving, cell division, and cell reaction operation are distributed to clusters using the Message Passing Interface (MPI). The Monte Carlo lattice update is parallelized on shared-memory SMP system using OpenMP. Because the Monte Carlo lattice update is much faster than the POE solving and SMP systems are more and more common, this hybrid approach achieves good performance and high accuracy at the same time. Based on the parallel Cellular Potts Model, we studied the avascular tumor growth using a multiscale model. The application and performance analysis show that the hybrid parallel framework is quite efficient. The hybrid parallel CPM can be used for the large scale simulation ({approx}10{sup 8} sites) of complex collective behavior of numerous cells ({approx}10{sup 6}).

  20. Research on GPU acceleration for Monte Carlo criticality calculation

    International Nuclear Information System (INIS)

    Xu, Q.; Yu, G.; Wang, K.

    2013-01-01

    The Monte Carlo (MC) neutron transport method can be naturally parallelized by multi-core architectures due to the dependency between particles during the simulation. The GPU+CPU heterogeneous parallel mode has become an increasingly popular way of parallelism in the field of scientific supercomputing. Thus, this work focuses on the GPU acceleration method for the Monte Carlo criticality simulation, as well as the computational efficiency that GPUs can bring. The 'neutron transport step' is introduced to increase the GPU thread occupancy. In order to test the sensitivity of the MC code's complexity, a 1D one-group code and a 3D multi-group general purpose code are respectively transplanted to GPUs, and the acceleration effects are compared. The result of numerical experiments shows considerable acceleration effect of the 'neutron transport step' strategy. However, the performance comparison between the 1D code and the 3D code indicates the poor scalability of MC codes on GPUs. (authors)

  1. Evaluation of tomographic image quality of extended and conventional parallel hole collimators using maximum likelihood expectation maximization algorithm by Monte Carlo simulations.

    Science.gov (United States)

    Moslemi, Vahid; Ashoor, Mansour

    2017-10-01

    One of the major problems associated with parallel hole collimators (PCs) is the trade-off between their resolution and sensitivity. To solve this problem, a novel PC - namely, extended parallel hole collimator (EPC) - was proposed, in which particular trapezoidal denticles were increased upon septa on the side of the detector. In this study, an EPC was designed and its performance was compared with that of two PCs, PC35 and PC41, with a hole size of 1.5 mm and hole lengths of 35 and 41 mm, respectively. The Monte Carlo method was used to calculate the important parameters such as resolution, sensitivity, scattering, and penetration ratio. A Jaszczak phantom was also simulated to evaluate the resolution and contrast of tomographic images, which were produced by the EPC6, PC35, and PC41 using the Monte Carlo N-particle version 5 code, and tomographic images were reconstructed by using maximum likelihood expectation maximization algorithm. Sensitivity of the EPC6 was increased by 20.3% in comparison with that of the PC41 at the identical spatial resolution and full-width at tenth of maximum here. Moreover, the penetration and scattering ratio of the EPC6 was 1.2% less than that of the PC41. The simulated phantom images show that the EPC6 increases contrast-resolution and contrast-to-noise ratio compared with those of PC41 and PC35. When compared with PC41 and PC35, EPC6 improved trade-off between resolution and sensitivity, reduced penetrating and scattering ratios, and produced images with higher quality. EPC6 can be used to increase detectability of more details in nuclear medicine images.

  2. The American Society for Therapeutic Radiology and Oncology (ASTRO) evidence-based review of the role of radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Mehta, Minesh P.; Tsao, May N.; Whelan, Timothy J.; Morris, David E.; Hayman, James A.; Flickinger, John C.; Mills, Michael; Rogers, C. Leland; Souhami, Luis

    2005-01-01

    Purpose: To systematically review the evidence for the use of stereotactic radiosurgery in adult patients with brain metastases. Methods: Key clinical questions to be addressed in this evidence-based review were identified. Outcomes considered were overall survival, quality of life or symptom control, brain tumor control or response and toxicity. MEDLINE (1990-2004 June Week 2), CANCERLIT (1990-2003), CINAHL (1990-2004 June Week 2), EMBASE (1990-2004 Week 25), and the Cochrane library (2004 issue 2) databases were searched using OVID. In addition, the Physician Data Query clinical trials database, the proceedings of the American Society of Clinical Oncology (ASCO) (1997-2004), ASTRO (1997-2004), and the European Society of Therapeutic Radiology and Oncology (ESTRO) (1997-2003) were searched. Data from the literature search were reviewed and tabulated. This process included an assessment of the level of evidence. Results: For patients with newly diagnosed brain metastases, managed with whole-brain radiotherapy alone vs. whole-brain radiotherapy and radiosurgery boost, there were three randomized controlled trials, zero prospective studies, and seven retrospective series (which satisfied inclusion criteria). For patients with up to three (<4 cm) newly diagnosed brain metastases (and in one study up to four brain metastases), radiosurgery boost with whole-brain radiotherapy significantly improves local brain control rates as compared with whole-brain radiotherapy alone (Level I-III evidence). In one large randomized trial, survival benefit with whole-brain radiotherapy was observed in patients with single brain metastasis. In this trial, an overall increased ability to taper down on steroid dose and an improvement in Karnofsky performance status was seen in patients who were treated with radiosurgery boost as compared with patients treated with whole-brain radiotherapy alone. However, Level I evidence regarding overall quality of life outcomes using a validated

  3. Fundamentals of Monte Carlo

    International Nuclear Information System (INIS)

    Wollaber, Allan Benton

    2016-01-01

    This is a powerpoint presentation which serves as lecture material for the Parallel Computing summer school. It goes over the fundamentals of the Monte Carlo calculation method. The material is presented according to the following outline: Introduction (background, a simple example: estimating @@), Why does this even work? (The Law of Large Numbers, The Central Limit Theorem), How to sample (inverse transform sampling, rejection), and An example from particle transport.

  4. Fundamentals of Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Wollaber, Allan Benton [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-16

    This is a powerpoint presentation which serves as lecture material for the Parallel Computing summer school. It goes over the fundamentals of the Monte Carlo calculation method. The material is presented according to the following outline: Introduction (background, a simple example: estimating π), Why does this even work? (The Law of Large Numbers, The Central Limit Theorem), How to sample (inverse transform sampling, rejection), and An example from particle transport.

  5. Acceptance, commissioning and quality control in radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  6. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  7. Performance studies of the parallel VIM code

    International Nuclear Information System (INIS)

    Shi, B.; Blomquist, R.N.

    1996-01-01

    In this paper, the authors evaluate the performance of the parallel version of the VIM Monte Carlo code on the IBM SPx at the High Performance Computing Research Facility at ANL. Three test problems with contrasting computational characteristics were used to assess effects in performance. A statistical method for estimating the inefficiencies due to load imbalance and communication is also introduced. VIM is a large scale continuous energy Monte Carlo radiation transport program and was parallelized using history partitioning, the master/worker approach, and p4 message passing library. Dynamic load balancing is accomplished when the master processor assigns chunks of histories to workers that have completed a previously assigned task, accommodating variations in the lengths of histories, processor speeds, and worker loads. At the end of each batch (generation), the fission sites and tallies are sent from each worker to the master process, contributing to the parallel inefficiency. All communications are between master and workers, and are serial. The SPx is a scalable 128-node parallel supercomputer with high-performance Omega switches of 63 microsec latency and 35 MBytes/sec bandwidth. For uniform and reproducible performance, they used only the 120 identical regular processors (IBM RS/6000) and excluded the remaining eight planet nodes, which may be loaded by other's jobs

  8. Monte Carlo: in the beginning and some great expectations

    International Nuclear Information System (INIS)

    Metropolis, N.

    1985-01-01

    The central theme will be on the historical setting and origins of the Monte Carlo Method. The scene was post-war Los Alamos Scientific Laboratory. There was an inevitability about the Monte Carlo Event: the ENIAC had recently enjoyed its meteoric rise (on a classified Los Alamos problem); Stan Ulam had returned to Los Alamos; John von Neumann was a frequent visitor. Techniques, algorithms, and applications developed rapidly at Los Alamos. Soon, the fascination of the Method reached wider horizons. The first paper was submitted for publication in the spring of 1949. In the summer of 1949, the first open conference was held at the University of California at Los Angeles. Of some interst perhaps is an account of Fermi's earlier, independent application in neutron moderation studies while at the University of Rome. The quantum leap expected with the advent of massively parallel processors will provide stimuli for very ambitious applications of the Monte Carlo Method in disciplines ranging from field theories to cosmology, including more realistic models in the neurosciences. A structure of multi-instruction sets for parallel processing is ideally suited for the Monte Carlo approach. One may even hope for a modest hardening of the soft sciences

  9. Assessment of neuropsychological changes in patients with arteriovenous malformation (AVM) after radiosurgery

    International Nuclear Information System (INIS)

    Wenz, Frederik; Steinvorth, Sarah; Wildermuth, Susanne; Lohr, Frank; Fuss, Martin; Debus, Juergen; Essig, Marco; Hacke, Werner; Wannenmacher, Michael

    1998-01-01

    Purpose: The purpose of this study was to investigate neuropsychological effects of radiosurgery in patients with cerebral arteriovenous malformation (AVM), with special focus on attention and memory. This report describes the study setup and presents the first results during a follow-up of up to 1 year. Materials and Methods: Seventy-nine patients were studied before, acutely after radiosurgery, and during the regular follow-up (subacute phase: Weeks 6-12, chronic phase: Months 6-12). Radiosurgery was performed using a modified linear accelerator (minimum doses to the target volume: 15-22 Gy, median 20 Gy). Estimated whole brain dose was 0.5 to 2 Gy. Neuropsychological testing included assessment of general intelligence (Wechsler Adult Intelligence Scale), attention (modified Trail-Making Test A, Digit Symbol Test, D2 Test, Wiener Determination Machine) and memory (Rey Auditory Verbal Learning Test, Benton Visual Retention Test). During follow-up, alternate test versions were used. Neuropsychological deficits were defined as a test score of at least one standard deviation (SD) below the mean of the normal distribution. Results: The pretherapeutic evaluation revealed marked deviations from the normal population; 24% had deficits in intelligence (range 23-31% in different subtests), attention (35%, 23-59%) and memory (48%, 31-61%). The overall percentage of aberrant results was reduced by 12% (memory) to 14% (attention) in the chronic phase up to 12 months after therapy. The improvement in test scores was significant (p < 0.05) in 3 of 4 subtests of attention functions. Conclusions: The acute tolerance of radiosurgery seems to be very good in these patients, showing no relevant increase in number of patients with neuropsychological deficits. Although the long-term follow-up needs to be further increased, our data indicate a tendency to slight improvement in the overall neuropsychological performance of AVM patients in the chronic phase after radiosurgery

  10. Radiosurgery of pituitary adenomas

    International Nuclear Information System (INIS)

    Kida, Yoshihisa

    2008-01-01

    The efficacy and role of gamma knife (GK) in the treatment of various pituitary adenomas are described on author's experience and discussed with literature. GK subjects are 328 patients (M 126/F 202, av. age of 47.8 y) in author's hospital, and satisfactory follow-up (32-44 mo) for evaluation has been possible in 253 cases, who had tumors non-functional (129 cases), producing ACTH (23), HGH (70) and PRL (31). Stereotactic GK radiosurgery is done with navigation by Gamma Plan based on enhanced MRI images at various doses, and evaluation in the follow-up period is performed by hormonal levels and MRI which give efficacy of complete response (CR), partial response (PR), MR and standard deviation (SD)/ progressive disease (PD) on the tumor size. The overall tumor control rate is found to be 95-100%. Effectiveness (CR and PR) is found as high as 77.4% in PRL-producing tumor (marginal dose 14-32 Gy), 65% in non-functioning (15-25 Gy), 61% in ACTH (19-30 Gy) and 60% in GH (19-31 Gy), of which tendency is similar to that in literature. Even in ACTH-producing tumor, low ACTH and cortisol levels persisted with tendency of improved obese and hypertensive symptoms. GK radiosurgery has limitations in the tissue size and distance between the tumor and optic nerve/chiasm, but for the enough small tumor, it gives satisfactorily long term efficacy. (R.T.)

  11. Do patients with a limited number of brain metastases need whole-brain radiotherapy in addition to radiosurgery?

    International Nuclear Information System (INIS)

    Rades, D.; Schild, S.E.

    2012-01-01

    Background: About 40% of patients with brain metastases have a very limited number of lesions and may be candidates for radiosurgery. Radiosurgery alone is superior to whole-brain radiotherapy (WBRT) alone for control of treated and new brain metastases. In patients with a good performance status, radiosurgery also resulted in better survival. However, the question is whether the results of radiosurgery alone can be further improved with additional WBRT. Methods: Information for this review was compiled by searching the PubMed and MEDLINE databases. Very important published meeting abstracts were also considered. Results: Based on both retrospective and prospective studies, the addition of WBRT to radiosurgery improved control of treated and new brain metastases but not survival. However, because a recurrence within the brain has a negative impact on neurocognitive function, it is important to achieve long-term control of brain metastases. Conclusion: The addition of WBRT provides significant benefits. Further randomized studies including adequate assessment of neurocognitive function and a follow-up period of at least 2 years are needed to help customize the treatment for individual patients. (orig.)

  12. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.

  13. Linear accelerator radiosurgery for trigeminal neuralgia: case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun [Dongguk University International Hospital, Goyang (Korea, Republic of)

    2006-06-15

    Trigeminal neuralgia is defined as an episodic electrical shock-like sensation in a dermatomal distribution of the trigeminal nerve. When medications fail to control pain, various procedures are used to attempt to control refractory pain. Of available procedures, stereotactic radiosurgery is the least invasive procedure and has been demonstrated to produce significant pain relief with minimal side effects. Recently, linear accelerators were introduced as a tool for radiosurgery of trigeminal neuralgia beneath the already accepted gamma unit. Author have experienced one case with trigeminal neuralgia treated with linear accelerator. The patient was treated with 85 Gy by means of 5 mm collimator directed to trigeminal nerve root entry zone. The patient obtained pain free without medication at 20 days after the procedure and remain pain free at 6 months after the procedure. He didn't experience facial numbness or other side effects.

  14. Advanced computers and Monte Carlo

    International Nuclear Information System (INIS)

    Jordan, T.L.

    1979-01-01

    High-performance parallelism that is currently available is synchronous in nature. It is manifested in such architectures as Burroughs ILLIAC-IV, CDC STAR-100, TI ASC, CRI CRAY-1, ICL DAP, and many special-purpose array processors designed for signal processing. This form of parallelism has apparently not been of significant value to many important Monte Carlo calculations. Nevertheless, there is much asynchronous parallelism in many of these calculations. A model of a production code that requires up to 20 hours per problem on a CDC 7600 is studied for suitability on some asynchronous architectures that are on the drawing board. The code is described and some of its properties and resource requirements ae identified to compare with corresponding properties and resource requirements are identified to compare with corresponding properties and resource requirements are identified to compare with corresponding properties and resources of some asynchronous multiprocessor architectures. Arguments are made for programer aids and special syntax to identify and support important asynchronous parallelism. 2 figures, 5 tables

  15. Reflections on early Monte Carlo calculations

    International Nuclear Information System (INIS)

    Spanier, J.

    1992-01-01

    Monte Carlo methods for solving various particle transport problems developed in parallel with the evolution of increasingly sophisticated computer programs implementing diffusion theory and low-order moments calculations. In these early years, Monte Carlo calculations and high-order approximations to the transport equation were seen as too expensive to use routinely for nuclear design but served as invaluable aids and supplements to design with less expensive tools. The earliest Monte Carlo programs were quite literal; i.e., neutron and other particle random walk histories were simulated by sampling from the probability laws inherent in the physical system without distoration. Use of such analogue sampling schemes resulted in a good deal of time being spent in examining the possibility of lowering the statistical uncertainties in the sample estimates by replacing simple, and intuitively obvious, random variables by those with identical means but lower variances

  16. The kpx, a program analyzer for parallelization

    International Nuclear Information System (INIS)

    Matsuyama, Yuji; Orii, Shigeo; Ota, Toshiro; Kume, Etsuo; Aikawa, Hiroshi.

    1997-03-01

    The kpx is a program analyzer, developed as a common technological basis for promoting parallel processing. The kpx consists of three tools. The first is ktool, that shows how much execution time is spent in program segments. The second is ptool, that shows parallelization overhead on the Paragon system. The last is xtool, that shows parallelization overhead on the VPP system. The kpx, designed to work for any FORTRAN cord on any UNIX computer, is confirmed to work well after testing on Paragon, SP2, SR2201, VPP500, VPP300, Monte-4, SX-4 and T90. (author)

  17. Stereotactic radiosurgery for spinal metastases: a literature review; Radiocirurgia estereotaxica para metastases de coluna vertebral: revisao de literatura

    Energy Technology Data Exchange (ETDEWEB)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala, E-mail: andjoaquim@yahoo.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2013-04-15

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy - melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  18. Surgery for acoustic neurinoma treated by gamma-knife radiosurgery. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tokuda, Kentaro; Inamura, Takanori; Uesaka, Toshio; Matsushima, Toshio; Fukui, Masashi [Kyushu Univ., Fukuoka (Japan). Graduate School of Medical Science; Kenai, Hiroyuki; Karashima, Atushi

    2001-08-01

    A 52-year-old woman had a history of left hearing loss for 5 years. An acoustic neurinoma with 3.2 cm in diameter was diagnosed and treated with gamma-knife radiosurgery (19 Gy of marginal dose) 1 year and 4 months ago. She developed headache, nausea, and visual disturbance 1 month prior to admission. Slight left facial palsy appeared after radiosurgery. Magnetic resonance imaging demonstrated the tumor with central necrosis in the left cerebellopontine angle cistern, increasing in size to 3.5 cm in diameter, and hydrocephalus. Tumor removal was performed incompletely, because of the fibrous appearance of the tumor and severe adherence with the surrounding cerebellar tissue. Facial palsy did not worsen after surgery. Since the hydrocephalus was not resolved, a right ventriculo-peritoneal shunt was inserted. The clinical course in this case suggests that tumor removal followed by radiosurgery was an approximately effective treatment for large acoustic neurinoma. (author)

  19. Gamma Knife radiosurgery for the treatment of intracranial dural arteriovenous fistulas

    Science.gov (United States)

    Dmytriw, Adam A; Schwartz, Michael L; Cusimano, Michael D; Mendes Pereira, Vitor; Krings, Timo; Tymianski, Michael; Radovanovic, Ivan

    2016-01-01

    Background Intracranial dural arteriovenous fistulae (DAVF) may present a treatment challenge. Endovascular embolization is in most cases the first line of treatment but does not always achieve cure. Gamma Knife (GK) radiosurgery represents an alternative treatment option, and the purpose of this study was to further evaluate its utility. Methods We reviewed all cases of DAVF treated between 2009 and 2016 at our institution with GK radiosurgery independently, or following failed/refused endovascular or surgical management. Patients’ clinical files, radiological images, catheter angiograms, and surgical DAVF disconnection reports were retrospectively reviewed. Results Sixteen DAVF (14 patients) treated by GK radiosurgery were identified. Eleven fistulae were aggressive and five were benign. Marginal doses ranged from 15 to 25 Gy. Target volumes ranged from 0.04 to 4.47 cm3. In all symptomatic patients, GK treatment resulted in symptom palliation. In 13/15 lesions, cure of symptoms (86.0%) was reported. One lesion was asymptomatic. Angiographic cure was achieved in eight cases (50%), small residual DAVF occurred in four, and four were unchanged. One patient developed headache that resolved at one year. No hemorrhage occurred during the follow-up period. There was no significant association between Borden type and cure rate. Prior failed endovascular treatment and small target volume were associated with lower rates of cure. Conclusions Stereotactic radiosurgery is viable treatment for DAVF. It is very effective in palliating symptoms as a de novo approach or adjunctive to endovascular therapy. In our experience it is only somewhat effective in achieving complete angiographic cure. PMID:28156167

  20. Hyper-parallel tempering Monte Carlo simulations of Ar adsorption in new models of microporous non-graphitizing activated carbon: effect of microporosity

    International Nuclear Information System (INIS)

    Terzyk, Artur P; Furmaniak, Sylwester; Gauden, Piotr A; Harris, Peter J F; Wloch, Jerzy; Kowalczyk, Piotr

    2007-01-01

    The adsorption of gases on microporous carbons is still poorly understood, partly because the structure of these carbons is not well known. Here, a model of microporous carbons based on fullerene-like fragments is used as the basis for a theoretical study of Ar adsorption on carbon. First, a simulation box was constructed, containing a plausible arrangement of carbon fragments. Next, using a new Monte Carlo simulation algorithm, two types of carbon fragments were gradually placed into the initial structure to increase its microporosity. Thirty six different microporous carbon structures were generated in this way. Using the method proposed recently by Bhattacharya and Gubbins (BG), the micropore size distributions of the obtained carbon models and the average micropore diameters were calculated. For ten chosen structures, Ar adsorption isotherms (87 K) were simulated via the hyper-parallel tempering Monte Carlo simulation method. The isotherms obtained in this way were described by widely applied methods of microporous carbon characterisation, i.e. Nguyen and Do, Horvath-Kawazoe, high-resolution α s plots, adsorption potential distributions and the Dubinin-Astakhov (DA) equation. From simulated isotherms described by the DA equation, the average micropore diameters were calculated using empirical relationships proposed by different authors and they were compared with those from the BG method

  1. A study of parallelizing O(N) Green-function-based Monte Carlo method for many fermions coupled with classical degrees of freedom

    International Nuclear Information System (INIS)

    Zhang Shixun; Yamagia, Shinichi; Yunoki, Seiji

    2013-01-01

    Models of fermions interacting with classical degrees of freedom are applied to a large variety of systems in condensed matter physics. For this class of models, Weiße [Phys. Rev. Lett. 102, 150604 (2009)] has recently proposed a very efficient numerical method, called O(N) Green-Function-Based Monte Carlo (GFMC) method, where a kernel polynomial expansion technique is used to avoid the full numerical diagonalization of the fermion Hamiltonian matrix of size N, which usually costs O(N 3 ) computational complexity. Motivated by this background, in this paper we apply the GFMC method to the double exchange model in three spatial dimensions. We mainly focus on the implementation of GFMC method using both MPI on a CPU-based cluster and Nvidia's Compute Unified Device Architecture (CUDA) programming techniques on a GPU-based (Graphics Processing Unit based) cluster. The time complexity of the algorithm and the parallel implementation details on the clusters are discussed. We also show the performance scaling for increasing Hamiltonian matrix size and increasing number of nodes, respectively. The performance evaluation indicates that for a 32 3 Hamiltonian a single GPU shows higher performance equivalent to more than 30 CPU cores parallelized using MPI

  2. Parallel tempering in full QCD with Wilson fermions

    International Nuclear Information System (INIS)

    Ilgenfritz, E.-M.; Kerler, W.; Mueller-Preussker, M.; Stueben, H.

    2002-01-01

    We study the performance of QCD simulations with dynamical Wilson fermions by combining the hybrid Monte Carlo algorithm with parallel tempering on 10 4 and 12 4 lattices. In order to compare tempered with standard simulations, covariance matrices between subensembles have to be formulated and evaluated using the general properties of autocorrelations of the parallel tempering algorithm. We find that rendering the hopping parameter κ dynamical does not lead to an essential improvement. We point out possible reasons for this observation and discuss more suitable ways of applying parallel tempering to QCD

  3. Modelling and parallel calculation of a kinetic boundary layer

    International Nuclear Information System (INIS)

    Perlat, Jean Philippe

    1998-01-01

    This research thesis aims at addressing reliability and cost issues in the calculation by numeric simulation of flows in transition regime. The first step has been to reduce calculation cost and memory space for the Monte Carlo method which is known to provide performance and reliability for rarefied regimes. Vector and parallel computers allow this objective to be reached. Here, a MIMD (multiple instructions, multiple data) machine has been used which implements parallel calculation at different levels of parallelization. Parallelization procedures have been adapted, and results showed that parallelization by calculation domain decomposition was far more efficient. Due to reliability issue related to the statistic feature of Monte Carlo methods, a new deterministic model was necessary to simulate gas molecules in transition regime. New models and hyperbolic systems have therefore been studied. One is chosen which allows thermodynamic values (density, average velocity, temperature, deformation tensor, heat flow) present in Navier-Stokes equations to be determined, and the equations of evolution of thermodynamic values are described for the mono-atomic case. Numerical resolution of is reported. A kinetic scheme is developed which complies with the structure of all systems, and which naturally expresses boundary conditions. The validation of the obtained 14 moment-based model is performed on shock problems and on Couette flows [fr

  4. Sampling from a polytope and hard-disk Monte Carlo

    International Nuclear Information System (INIS)

    Kapfer, Sebastian C; Krauth, Werner

    2013-01-01

    The hard-disk problem, the statics and the dynamics of equal two-dimensional hard spheres in a periodic box, has had a profound influence on statistical and computational physics. Markov-chain Monte Carlo and molecular dynamics were first discussed for this model. Here we reformulate hard-disk Monte Carlo algorithms in terms of another classic problem, namely the sampling from a polytope. Local Markov-chain Monte Carlo, as proposed by Metropolis et al. in 1953, appears as a sequence of random walks in high-dimensional polytopes, while the moves of the more powerful event-chain algorithm correspond to molecular dynamics evolution. We determine the convergence properties of Monte Carlo methods in a special invariant polytope associated with hard-disk configurations, and the implications for convergence of hard-disk sampling. Finally, we discuss parallelization strategies for event-chain Monte Carlo and present results for a multicore implementation

  5. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Kondziolka, D; Flickinger, J; Lunsford, L D; Young, R; Vermeulen, S; Duma, C; Jacques, D B; Rand, R; Regis, J; Peragut, J C; Epstein, M H; Lindquist, C

    1995-07-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of {>=} 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  6. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    International Nuclear Information System (INIS)

    Kondziolka, D.; Flickinger, J.; Lunsford, L.D.; Young, R.; Vermeulen, S.; Duma, C.; Jacques, D.B.; Rand, R.; Regis, J.; Peragut, J.C.; Epstein, M.H.; Lindquist, C.

    1995-01-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of ≥ 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  7. Implementing Shared Memory Parallelism in MCBEND

    Directory of Open Access Journals (Sweden)

    Bird Adam

    2017-01-01

    Full Text Available MCBEND is a general purpose radiation transport Monte Carlo code from AMEC Foster Wheelers’s ANSWERS® Software Service. MCBEND is well established in the UK shielding community for radiation shielding and dosimetry assessments. The existing MCBEND parallel capability effectively involves running the same calculation on many processors. This works very well except when the memory requirements of a model restrict the number of instances of a calculation that will fit on a machine. To more effectively utilise parallel hardware OpenMP has been used to implement shared memory parallelism in MCBEND. This paper describes the reasoning behind the choice of OpenMP, notes some of the challenges of multi-threading an established code such as MCBEND and assesses the performance of the parallel method implemented in MCBEND.

  8. The Metropolis Monte Carlo method with CUDA enabled Graphic Processing Units

    Energy Technology Data Exchange (ETDEWEB)

    Hall, Clifford [Computational Materials Science Center, George Mason University, 4400 University Dr., Fairfax, VA 22030 (United States); School of Physics, Astronomy, and Computational Sciences, George Mason University, 4400 University Dr., Fairfax, VA 22030 (United States); Ji, Weixiao [Computational Materials Science Center, George Mason University, 4400 University Dr., Fairfax, VA 22030 (United States); Blaisten-Barojas, Estela, E-mail: blaisten@gmu.edu [Computational Materials Science Center, George Mason University, 4400 University Dr., Fairfax, VA 22030 (United States); School of Physics, Astronomy, and Computational Sciences, George Mason University, 4400 University Dr., Fairfax, VA 22030 (United States)

    2014-02-01

    We present a CPU–GPU system for runtime acceleration of large molecular simulations using GPU computation and memory swaps. The memory architecture of the GPU can be used both as container for simulation data stored on the graphics card and as floating-point code target, providing an effective means for the manipulation of atomistic or molecular data on the GPU. To fully take advantage of this mechanism, efficient GPU realizations of algorithms used to perform atomistic and molecular simulations are essential. Our system implements a versatile molecular engine, including inter-molecule interactions and orientational variables for performing the Metropolis Monte Carlo (MMC) algorithm, which is one type of Markov chain Monte Carlo. By combining memory objects with floating-point code fragments we have implemented an MMC parallel engine that entirely avoids the communication time of molecular data at runtime. Our runtime acceleration system is a forerunner of a new class of CPU–GPU algorithms exploiting memory concepts combined with threading for avoiding bus bandwidth and communication. The testbed molecular system used here is a condensed phase system of oligopyrrole chains. A benchmark shows a size scaling speedup of 60 for systems with 210,000 pyrrole monomers. Our implementation can easily be combined with MPI to connect in parallel several CPU–GPU duets. -- Highlights: •We parallelize the Metropolis Monte Carlo (MMC) algorithm on one CPU—GPU duet. •The Adaptive Tempering Monte Carlo employs MMC and profits from this CPU—GPU implementation. •Our benchmark shows a size scaling-up speedup of 62 for systems with 225,000 particles. •The testbed involves a polymeric system of oligopyrroles in the condensed phase. •The CPU—GPU parallelization includes dipole—dipole and Mie—Jones classic potentials.

  9. The Metropolis Monte Carlo method with CUDA enabled Graphic Processing Units

    International Nuclear Information System (INIS)

    Hall, Clifford; Ji, Weixiao; Blaisten-Barojas, Estela

    2014-01-01

    We present a CPU–GPU system for runtime acceleration of large molecular simulations using GPU computation and memory swaps. The memory architecture of the GPU can be used both as container for simulation data stored on the graphics card and as floating-point code target, providing an effective means for the manipulation of atomistic or molecular data on the GPU. To fully take advantage of this mechanism, efficient GPU realizations of algorithms used to perform atomistic and molecular simulations are essential. Our system implements a versatile molecular engine, including inter-molecule interactions and orientational variables for performing the Metropolis Monte Carlo (MMC) algorithm, which is one type of Markov chain Monte Carlo. By combining memory objects with floating-point code fragments we have implemented an MMC parallel engine that entirely avoids the communication time of molecular data at runtime. Our runtime acceleration system is a forerunner of a new class of CPU–GPU algorithms exploiting memory concepts combined with threading for avoiding bus bandwidth and communication. The testbed molecular system used here is a condensed phase system of oligopyrrole chains. A benchmark shows a size scaling speedup of 60 for systems with 210,000 pyrrole monomers. Our implementation can easily be combined with MPI to connect in parallel several CPU–GPU duets. -- Highlights: •We parallelize the Metropolis Monte Carlo (MMC) algorithm on one CPU—GPU duet. •The Adaptive Tempering Monte Carlo employs MMC and profits from this CPU—GPU implementation. •Our benchmark shows a size scaling-up speedup of 62 for systems with 225,000 particles. •The testbed involves a polymeric system of oligopyrroles in the condensed phase. •The CPU—GPU parallelization includes dipole—dipole and Mie—Jones classic potentials.

  10. Vagus nerve stimulation and stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kawai, Kensuke

    2005-01-01

    Vagus nerve stimulation and stereotactic radiosurgery represent novel and less invasive therapeutics for medically intractable epilepsy. Chronic stimulation of the left vagus nerve with implanted generator and electrodes inhibits seizure susceptibility of the cerebral cortices. While the underlying mechanisms of the effect remains to be further elucidated, the efficacy and safety of vagus nerve stimulation have been established by randomized clinical trials in the United States and European countries. It has been widely accepted as a treatment option for patients with medically intractable epilepsy and for whom brain surgery is not indicated. The primary indication of vagus nerve stimulation in the clinical trials was localization-related epilepsy in adult patients but efficacy in a wide range of patient groups such as generalized epilepsy and children has been reported. Improvements in daytime alertness, mood, higher cognitive functions and overall quality of life have been reported other than the effect on epileptic seizures. Since the devices are not approved for clinical use in Japan by the Health, Labor and Welfare Ministry, there exist barriers to provide this treatment to patients at present. Stereotactic radiosurgery has been used for temporal lobe epilepsy and hypothalamic hamartoma, but it is still controversial whether the therapy is more effective and less invasive than brain surgery. Promising results of gamma knife radiosurgery for medically intractable temporal lobe epilepsy with unilateral hippocampal sclerosis have been reported essentially from one French center. Results from others were not as favorable. There seems to be an unignorable risk of brain edema and radiation necrosis when the delivered dose over the medial temporal structures is high enough to abolish epileptic seizures. A randomized clinical trial comparing different marginal doses is ongoing in the United States. Clinical trials like this, technical advancement and standardization

  11. Kinetic-Monte-Carlo-Based Parallel Evolution Simulation Algorithm of Dust Particles

    Directory of Open Access Journals (Sweden)

    Xiaomei Hu

    2014-01-01

    Full Text Available The evolution simulation of dust particles provides an important way to analyze the impact of dust on the environment. KMC-based parallel algorithm is proposed to simulate the evolution of dust particles. In the parallel evolution simulation algorithm of dust particles, data distribution way and communication optimizing strategy are raised to balance the load of every process and reduce the communication expense among processes. The experimental results show that the simulation of diffusion, sediment, and resuspension of dust particles in virtual campus is realized and the simulation time is shortened by parallel algorithm, which makes up for the shortage of serial computing and makes the simulation of large-scale virtual environment possible.

  12. Acceleration and sensitivity analysis of lattice kinetic Monte Carlo simulations using parallel processing and rate constant rescaling.

    Science.gov (United States)

    Núñez, M; Robie, T; Vlachos, D G

    2017-10-28

    Kinetic Monte Carlo (KMC) simulation provides insights into catalytic reactions unobtainable with either experiments or mean-field microkinetic models. Sensitivity analysis of KMC models assesses the robustness of the predictions to parametric perturbations and identifies rate determining steps in a chemical reaction network. Stiffness in the chemical reaction network, a ubiquitous feature, demands lengthy run times for KMC models and renders efficient sensitivity analysis based on the likelihood ratio method unusable. We address the challenge of efficiently conducting KMC simulations and performing accurate sensitivity analysis in systems with unknown time scales by employing two acceleration techniques: rate constant rescaling and parallel processing. We develop statistical criteria that ensure sufficient sampling of non-equilibrium steady state conditions. Our approach provides the twofold benefit of accelerating the simulation itself and enabling likelihood ratio sensitivity analysis, which provides further speedup relative to finite difference sensitivity analysis. As a result, the likelihood ratio method can be applied to real chemistry. We apply our methodology to the water-gas shift reaction on Pt(111).

  13. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi

    1998-01-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  14. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi [Keio Univ., Tokyo (Japan) School of Medicine] [and others

    1998-08-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  15. Image-guided robotic radiosurgery for spinal metastases

    International Nuclear Information System (INIS)

    Gibbs, Iris C.; Kamnerdsupaphon, Pimkhuan; Ryu, Mi-Ryeong; Dodd, Robert; Kiernan, Michaela; Chang, Steven D.; Adler, John R.

    2007-01-01

    Background and Purpose: To determine the effectiveness and safety of image-guided robotic radiosurgery for spinal metastases. Materials/Methods: From 1996 to 2005, 74 patients with 102 spinal metastases were treated using the CyberKnife TM at Stanford University. Sixty-two (84%) patients were symptomatic. Seventy-four percent (50/68) of previously treated patients had prior radiation. Using the CyberKnife TM , 16-25 Gy in 1-5 fractions was delivered. Patients were followed clinically and radiographically for at least 3 months or until death. Results: With mean follow-up of 9 months (range 0-33 months), 36 patients were alive and 38 were dead at last follow-up. No death was treatment related. Eighty-four (84%) percent of symptomatic patients experienced improvement or resolution of symptoms after treatment. Three patients developed treatment-related spinal injury. Analysis of dose-volume parameters and clinical parameters failed to identify predictors of spinal cord injury. Conclusions: Robotic radiosurgery is effective and generally safe for spinal metastases even in previously irradiated patients

  16. SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

    Energy Technology Data Exchange (ETDEWEB)

    Piao, J [PLA General Hospital, Beijing (China); PLA 302 Hospital, Beijing (China); Xu, S [PLA General Hospital, Beijing (China); Tsinghua University, Beijing (China); Wu, Z; Liu, Y [Tsinghua University, Beijing (China); Li, Y [Beihang University, Beijing (China); Qu, B [PLA General Hospital, Beijing (China); Duan, X [PLA 302 Hospital, Beijing (China)

    2016-06-15

    Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant

  17. Calculation of cranial nerve complication probability for acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Foote, Kelly D.; Friedman, William A.; Bova, Francis J.

    2000-01-01

    Purpose: Estimations of complications from stereotactic radiosurgery usually rely simply on dose-volume or dose-diameter isoeffect curves. Due to the sparse clinical data available, these curves have typically not considered the target location in the brain, target histology, or treatment plan conformality as parameters in the calculation. In this study, a predictive model was generated to estimate the probability of cranial neuropathies as a result of acoustic schwannoma radiosurgery. Methods and Materials: The dose-volume histogram reduction scheme was used to calculate the normal tissue complication probability (NTCP) from brainstem dose-volume histograms. The model's fitting parameters were optimized to provide the best fit to the observed complication data for acoustic neuroma patients treated with stereotactic radiosurgery at the University of Florida. The calculation was then applied to the remainder of the patients in the database. Results: The best fit to our clinical data was obtained using n = 0.04, m = 0.15, and no. alphano. /no. betano. = 2.1 Gy -1 . Although the fitting parameter m is relatively consistent with ranges found in the literature, both the volume parameter, n, and no. alphano. /no. betano. are much smaller than the values quoted in the literature. The fit to our clinical data indicates that brainstem, or possibly a specific portion of the brainstem, is more radiosensitive than the parameters in the literature indicate, and that there is very little volume effect; in other words, irradiation of a small fraction of the brainstem yields NTCPs that are nearly as high as those calculated for entire volume irradiation. These new fitting parameters are specific to acoustic neuroma radiosurgery, and the small volume effect that we observe may be an artifact of the fixed relationship of acoustic tumors to specific regions of the brainstem. Applying the model to our patient database, we calculate an average NTCP of 7.2% for patients who had no

  18. Quantum Monte Carlo for vibrating molecules

    International Nuclear Information System (INIS)

    Brown, W.R.; Lawrence Berkeley National Lab., CA

    1996-08-01

    Quantum Monte Carlo (QMC) has successfully computed the total electronic energies of atoms and molecules. The main goal of this work is to use correlation function quantum Monte Carlo (CFQMC) to compute the vibrational state energies of molecules given a potential energy surface (PES). In CFQMC, an ensemble of random walkers simulate the diffusion and branching processes of the imaginary-time time dependent Schroedinger equation in order to evaluate the matrix elements. The program QMCVIB was written to perform multi-state VMC and CFQMC calculations and employed for several calculations of the H 2 O and C 3 vibrational states, using 7 PES's, 3 trial wavefunction forms, two methods of non-linear basis function parameter optimization, and on both serial and parallel computers. In order to construct accurate trial wavefunctions different wavefunctions forms were required for H 2 O and C 3 . In order to construct accurate trial wavefunctions for C 3 , the non-linear parameters were optimized with respect to the sum of the energies of several low-lying vibrational states. In order to stabilize the statistical error estimates for C 3 the Monte Carlo data was collected into blocks. Accurate vibrational state energies were computed using both serial and parallel QMCVIB programs. Comparison of vibrational state energies computed from the three C 3 PES's suggested that a non-linear equilibrium geometry PES is the most accurate and that discrete potential representations may be used to conveniently determine vibrational state energies

  19. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery.

    Science.gov (United States)

    Yu, Zhan; Vanstalle, Marie; La Tessa, Chiara; Jiang, Guo-Liang; Durante, Marco

    2012-07-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery.

  20. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery

    International Nuclear Information System (INIS)

    Yu, Z.; Vanstalle, M.; La Tessa, C.; Durante, M.; Jiang Guoliang

    2012-01-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery. (author)

  1. Radiation tolerance of normal temporal bone structures: implications for gamma knife stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Linskey, Mark E.; Johnstone, Peter A.

    2003-01-01

    Popular current thought states that hearing loss and facial weakness after radiosurgery of vestibular schwannomas is a function of cranial nerve damage. Although this may be true in some cases, the middle and inner ear contain rich networks of other sensitive structures that are at risk after radiotherapy and that may contribute to toxicity afterward. We reviewed the limited reported data regarding radiation tolerance of external, middle, and inner ear structures, and perspectives for therapy with gamma knife stereotactic radiosurgery are addressed

  2. Intracranial radiosurgery in the Netherlands. A planning comparison of available systems with regard to physical aspects and workload.

    NARCIS (Netherlands)

    Schoonbeek, A.; Monshouwer, R.; Hanssens, P.; Raaijmakers, E.; Nowak, P.; Marijnissen, J.P.; Lagerwaard, F.J.; Cuijpers, J.P.; Vonk, E.J.; Maazen, R.W.M. van der

    2010-01-01

    Different planning and treatment systems for intracranial stereotactic radiosurgery available in the Netherlands are compared. The systems for intracranial radiosurgery include: Gamma Knife, Cyberknife, Novalis, and Tomotherapy. Electronic data of 5 patients was transferred to all participating

  3. Dose and diameter relationships for facial, trigeminal, and acoustic neuropathies following acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Lunsford, L. Dade

    1996-01-01

    Purpose and objective: To define the relationships between dose and tumor diameter for the risks of developing trigeminal, facial, and acoustic neuropathies after acoustic neuroma radiosurgery, a large single-institution experience was analyzed. Materials and methods: Two hundred and thirty-eight patients with unilateral acoustic neuromas who underwent Gamma knife radiosurgery between 1987-1994 with 6-91 months of follow-up (median 30 months) were studied. Minimum tumor doses were 12-20 Gy (median 15 Gy). Transverse tumor diameter varied from 0.3-5.5 cm (median 2.1 cm). The relationships of dose and diameter to the development of cranial neuropathies were delineated by multivariate logistic regression. Results: The development of post-radiosurgery neuropathies affecting cranial nerves V, VII, and VIII were correlated with minimum tumor dose and transverse tumor diameter (P min for VIII where P=0.10). A comparison of the dose-diameter response curves showed the acoustic nerve to be the most sensitive to doses of 12-16 Gy and the facial nerve to be the least sensitive. Conclusion: The risks of developing trigeminal, facial, and acoustic neuropathies following acoustic neuroma radiosurgery can be predicted from the transverse tumor diameter and the minimum tumor dose using models constructed from data presently available

  4. Combinatorial geometry domain decomposition strategies for Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Li, G.; Zhang, B.; Deng, L.; Mo, Z.; Liu, Z.; Shangguan, D.; Ma, Y.; Li, S.; Hu, Z. [Institute of Applied Physics and Computational Mathematics, Beijing, 100094 (China)

    2013-07-01

    Analysis and modeling of nuclear reactors can lead to memory overload for a single core processor when it comes to refined modeling. A method to solve this problem is called 'domain decomposition'. In the current work, domain decomposition algorithms for a combinatorial geometry Monte Carlo transport code are developed on the JCOGIN (J Combinatorial Geometry Monte Carlo transport INfrastructure). Tree-based decomposition and asynchronous communication of particle information between domains are described in the paper. Combination of domain decomposition and domain replication (particle parallelism) is demonstrated and compared with that of MERCURY code. A full-core reactor model is simulated to verify the domain decomposition algorithms using the Monte Carlo particle transport code JMCT (J Monte Carlo Transport Code), which has being developed on the JCOGIN infrastructure. Besides, influences of the domain decomposition algorithms to tally variances are discussed. (authors)

  5. Combinatorial geometry domain decomposition strategies for Monte Carlo simulations

    International Nuclear Information System (INIS)

    Li, G.; Zhang, B.; Deng, L.; Mo, Z.; Liu, Z.; Shangguan, D.; Ma, Y.; Li, S.; Hu, Z.

    2013-01-01

    Analysis and modeling of nuclear reactors can lead to memory overload for a single core processor when it comes to refined modeling. A method to solve this problem is called 'domain decomposition'. In the current work, domain decomposition algorithms for a combinatorial geometry Monte Carlo transport code are developed on the JCOGIN (J Combinatorial Geometry Monte Carlo transport INfrastructure). Tree-based decomposition and asynchronous communication of particle information between domains are described in the paper. Combination of domain decomposition and domain replication (particle parallelism) is demonstrated and compared with that of MERCURY code. A full-core reactor model is simulated to verify the domain decomposition algorithms using the Monte Carlo particle transport code JMCT (J Monte Carlo Transport Code), which has being developed on the JCOGIN infrastructure. Besides, influences of the domain decomposition algorithms to tally variances are discussed. (authors)

  6. Radiosurgery with the gamma knife; Radiochirurgie mit dem Gamma-Knife

    Energy Technology Data Exchange (ETDEWEB)

    Wowra, B.; Reulen, H.J.

    1996-05-10

    Radiosurgery is a novel modality introduced by the neurosurgeon Lars Leksell. For the most important lesions, (arteriovenous angiomas, benign tumors in the base of the skull, formation of metastases in the brain), radiosurgery is a valuable additional tool in the range of therapies available to the benefit of patients. The gamma knife has been gaining a leading rank in the range of therapies applied in Germany. (orig.) [Deutsch] Radiochirurgie ist ein neues, von dem Neurochirurgen Lars Leksell konzipiertes Prinzip. Bei den wichtigsten Indikationen (arteriovenoese Angiome, gutartige Tumoren der Schaedelbasis, Hirnmetastasen etc.) bereichert und ergaenzt die Radiochirurgie das therapeutische Arsenal der Neurochirurgie zum Vorteil der Patienten betraechtlich. Dem Gamma-Knife kommt jetzt auch in Deutschland ein prominenter Platz unter den verschiedenen radiochirurgischen Verfahren zu. (orig.)

  7. Optic neuritis in a case after gamma knife radiosurgery for relapsed pituitary adenoma

    International Nuclear Information System (INIS)

    Hosoda, Atsuhide; Mizunoya, Satoshi; Abe, Hideki; Kanai, Hidehito; Ikeda, Kazutoshi; Kidahashi, Hisaharu; Suzuki, Masanobu

    2008-01-01

    The purpose of this study was to report a case of optic neuritis after gamma knife radiosurgery for pituitary adenoma. A 41-year-old woman presented with impaired vision in both eyes since 5 days before. She had received surgery for pituitary tumor 5 years before. She was treated by gamma knife radiosurgery for relapse of tumor 50 days before. Her corrected visual acuity was 0.5 right and 0.6 left. She had abnormal color sense. Flicker fusion frequency was decreased in both eyes. Both eyes showed enlarged blind spot and relative scotoma in the superior sector. Magnetic resonance imaging (MRI) showed enhanced signal in the optic nerve sheath. These findings led to the diagnosis of optic neuritis. Pulsed corticosteroid therapy was followed by improved vision of 1.2 in either eye. She has been doing well for 18 months until present. This case illustrates that optic neuritis may develop after gamma knife radiosurgery. (author)

  8. Off-diagonal expansion quantum Monte Carlo.

    Science.gov (United States)

    Albash, Tameem; Wagenbreth, Gene; Hen, Itay

    2017-12-01

    We propose a Monte Carlo algorithm designed to simulate quantum as well as classical systems at equilibrium, bridging the algorithmic gap between quantum and classical thermal simulation algorithms. The method is based on a decomposition of the quantum partition function that can be viewed as a series expansion about its classical part. We argue that the algorithm not only provides a theoretical advancement in the field of quantum Monte Carlo simulations, but is optimally suited to tackle quantum many-body systems that exhibit a range of behaviors from "fully quantum" to "fully classical," in contrast to many existing methods. We demonstrate the advantages, sometimes by orders of magnitude, of the technique by comparing it against existing state-of-the-art schemes such as path integral quantum Monte Carlo and stochastic series expansion. We also illustrate how our method allows for the unification of quantum and classical thermal parallel tempering techniques into a single algorithm and discuss its practical significance.

  9. Cognitive function in patients with cerebral arteriovenous malformations after radiosurgery: prospective long-term follow-up

    International Nuclear Information System (INIS)

    Steinvorth, Sarah; Wenz, Frederik; Wildermuth, Susanne; Essig, Marco; Fuss, Martin; Lohr, Frank; Debus, Juergen; Wannenmacher, Michael; Hacke, Werner

    2002-01-01

    Purpose: To evaluate the long-term cognitive function of patients with cerebral arteriovenous malformations (AVMs) after radiosurgery. Methods and Materials: The data of 95 AVM patients were prospectively assessed up to 3 years after radiosurgery. Of these patients, 39 had a follow-up of at least 2 years. Radiosurgery was performed using a modified linear accelerator (minimal doses to the target volume 15-22 Gy, median dose 20). The neuropsychological evaluation included testing of intelligence, attention, and memory. The effect of a preexisting intracranial hemorrhage, as well as AVM occlusion, on cognitive functions was analyzed after 1 and 2 years. Results: No cognitive declines were observed during follow-up. Instead significant improvements occurred in intelligence (1 year, +6.1 IQ points; 2 years, +5.1 IQ points), memory (1 year, +18.3 percentile score; 2 years, +12.2 percentile score), and attention (1 year, +19 percentile score; 2 years, +18 percentile score). Patients without previous intracranial hemorrhage improved more than patients with intracranial hemorrhage, although this difference was not statistically significant. The role of AVM occlusion on cognitive function is not clear at present. Conclusion: Radiosurgery does not induce measurable deterioration of cognitive function in patients with cerebral AVMs

  10. Direct Simulation Monte Carlo (DSMC) on the Connection Machine

    International Nuclear Information System (INIS)

    Wong, B.C.; Long, L.N.

    1992-01-01

    The massively parallel computer Connection Machine is utilized to map an improved version of the direct simulation Monte Carlo (DSMC) method for solving flows with the Boltzmann equation. The kinetic theory is required for analyzing hypersonic aerospace applications, and the features and capabilities of the DSMC particle-simulation technique are discussed. The DSMC is shown to be inherently massively parallel and data parallel, and the algorithm is based on molecule movements, cross-referencing their locations, locating collisions within cells, and sampling macroscopic quantities in each cell. The serial DSMC code is compared to the present parallel DSMC code, and timing results show that the speedup of the parallel version is approximately linear. The correct physics can be resolved from the results of the complete DSMC method implemented on the connection machine using the data-parallel approach. 41 refs

  11. Accelerating population balance-Monte Carlo simulation for coagulation dynamics from the Markov jump model, stochastic algorithm and GPU parallel computing

    International Nuclear Information System (INIS)

    Xu, Zuwei; Zhao, Haibo; Zheng, Chuguang

    2015-01-01

    This paper proposes a comprehensive framework for accelerating population balance-Monte Carlo (PBMC) simulation of particle coagulation dynamics. By combining Markov jump model, weighted majorant kernel and GPU (graphics processing unit) parallel computing, a significant gain in computational efficiency is achieved. The Markov jump model constructs a coagulation-rule matrix of differentially-weighted simulation particles, so as to capture the time evolution of particle size distribution with low statistical noise over the full size range and as far as possible to reduce the number of time loopings. Here three coagulation rules are highlighted and it is found that constructing appropriate coagulation rule provides a route to attain the compromise between accuracy and cost of PBMC methods. Further, in order to avoid double looping over all simulation particles when considering the two-particle events (typically, particle coagulation), the weighted majorant kernel is introduced to estimate the maximum coagulation rates being used for acceptance–rejection processes by single-looping over all particles, and meanwhile the mean time-step of coagulation event is estimated by summing the coagulation kernels of rejected and accepted particle pairs. The computational load of these fast differentially-weighted PBMC simulations (based on the Markov jump model) is reduced greatly to be proportional to the number of simulation particles in a zero-dimensional system (single cell). Finally, for a spatially inhomogeneous multi-dimensional (multi-cell) simulation, the proposed fast PBMC is performed in each cell, and multiple cells are parallel processed by multi-cores on a GPU that can implement the massively threaded data-parallel tasks to obtain remarkable speedup ratio (comparing with CPU computation, the speedup ratio of GPU parallel computing is as high as 200 in a case of 100 cells with 10 000 simulation particles per cell). These accelerating approaches of PBMC are

  12. Gamma knife radiosurgery for arteriovenous malformation in children

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Takayuki; Kobayashi, Tatsuya [Komaki City Hospital, Aichi (Japan)

    1995-04-01

    Intracranial arteriovenous malformations (AVM) of 38 children were treated by gamma knife radiosurgery. Their clinical courses and the effect of the treatment in 19 patients who had angiographies are described. There were 21 boys and 17 girls with a mean age of 11.2 years. The initial signs and symptoms were: intracranial hemorrhage in 32, seizures in 4, and headache in 2. Prior to the radiosurgery, craniotomy was performed in 10 patients, ventricular drainage, in 8, ventriculoperitoneal shunting in 4, and intravascular embolization in 3. The AVM was in the parietal lobe in 8 patients, in the thalamus in 7, in the occipital lobe in 5, in the temporal lobe in 4, in the basal ganglia in 4, in the corpus callosum in 3, and in other locations in 8. The mean diameter of the nidus was 18.9 mm. According to Spetzler`s classification of AVM, 23 (60.5%) were grade III, 10 were grade II, 3 were grade IV, and 2 were grade VI. The mean maximum dose was 36.3 Gy, and the mean peripheral dose was 20.2 Gy. Follow-up angiography was done in 19 patients during a mean follow-up period of 14.9 months. Complete occlusion of the nidus was obtained within 1 year in 10 of 15 patients (67%). All 6 patients who underwent angiography 2 years after treatment showed complete obliteration of the AVM. Only 1 patient developed hemiparesis due to radiation necrosis. It is considered that occlusion of AVMs by gamma knife radiosurgery is probably more effective and safer in children than in adults. (author).

  13. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    Science.gov (United States)

    Linskey, Mark E

    2013-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the

  14. Monte Carlo advances for the Eolus Asci Project

    International Nuclear Information System (INIS)

    Hendrick, J. S.; McKinney, G. W.; Cox, L. J.

    2000-01-01

    The Eolus ASCI project includes parallel, 3-D transport simulation for various nuclear applications. The codes developed within this project provide neutral and charged particle transport, detailed interaction physics, numerous source and tally capabilities, and general geometry packages. One such code is MCNPW which is a general purpose, 3-dimensional, time-dependent, continuous-energy Monte Carlo fully-coupled N-Particle transport code. Significant advances are also being made in the areas of modern software engineering and parallel computing. These advances are described in detail

  15. Stereotactic radiosurgery XX: ocular neuromyotonia in association with gamma knife radiosurgery

    Science.gov (United States)

    McQuillan, Joe; Plowman, P Nicholas; MacDougall, Niall; Blackburn, Philip; Sabin, H Ian; Ali, Nadeem; Drake, William M

    2015-01-01

    Summary We report three patients who developed symptoms and signs of ocular neuromyotonia (ONM) 3–6 months after receiving gamma knife radiosurgery (GKS) for functioning pituitary tumours. All three patients were complex, requiring multi-modality therapy and all had received prior external irradiation to the sellar region. Although direct causality cannot be attributed, the timing of the development of the symptoms would suggest that the GKS played a contributory role in the development of this rare problem, which we suggest clinicians should be aware of as a potential complication. Learning points GKS can cause ONM, presenting as intermittent diplopia.ONM can occur quite rapidly after treatment with GKS.Treatment with carbamazepine is effective and improve patient's quality of life. PMID:26294961

  16. Do patients with very few brain metastases from breast cancer benefit from whole-brain radiotherapy in addition to radiosurgery?

    International Nuclear Information System (INIS)

    Rades, Dirk; Huttenlocher, Stefan; Hornung, Dagmar; Blanck, Oliver; Schild, Steven E; Fischer, Dorothea

    2014-01-01

    An important issue in palliative radiation oncology is the whether whole-brain radiotherapy should be added to radiosurgery when treating a limited number of brain metastases. To optimize personalized treatment of cancer patients with brain metastases, the value of whole-brain radiotherapy should be described separately for each tumor entity. This study investigated the role of whole-brain radiotherapy added to radiosurgery in breast cancer patients. Fifty-eight patients with 1–3 brain metastases from breast cancer were included in this retrospective study. Of these patients, 30 were treated with radiosurgery alone and 28 with radiosurgery plus whole-brain radiotherapy. Both groups were compared for local control of the irradiated metastases, freedom from new brain metastases and survival. Furthermore, eight additional factors were analyzed including dose of radiosurgery, age at radiotherapy, Eastern Cooperative Oncology Group (ECOG) performance score, number of brain metastases, maximum diameter of all brain metastases, site of brain metastases, extra-cranial metastases and the time from breast cancer diagnosis to radiotherapy. The treatment regimen had no significant impact on local control in the univariate analysis (p = 0.59). Age ≤59 years showed a trend towards improved local control on univariate (p = 0.066) and multivariate analysis (p = 0.07). On univariate analysis, radiosurgery plus whole-brain radiotherapy (p = 0.040) and ECOG 0–1 (p = 0.012) showed positive associations with freedom from new brain metastases. Both treatment regimen (p = 0.039) and performance status (p = 0.028) maintained significance on multivariate analysis. ECOG 0–1 was positively correlated with survival on univariate analysis (p < 0.001); age ≤59 years showed a strong trend (p = 0.054). On multivariate analysis, performance status (p < 0.001) and age (p = 0.041) were significant. In breast cancer patients with few brain metastases, radiosurgery plus whole

  17. Characterization of parallel-hole collimator using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Karunanithi, Sellam; Kumar, Praveen; Bal, Chandrasekhar; Kumar, Rakesh

    2015-01-01

    Accuracy of in vivo activity quantification improves after the correction of penetrated and scattered photons. However, accurate assessment is not possible with physical experiment. We have used Monte Carlo Simulation to accurately assess the contribution of penetrated and scattered photons in the photopeak window. Simulations were performed with Simulation of Imaging Nuclear Detectors Monte Carlo Code. The simulations were set up in such a way that it provides geometric, penetration, and scatter components after each simulation and writes binary images to a data file. These components were analyzed graphically using Microsoft Excel (Microsoft Corporation, USA). Each binary image was imported in software (ImageJ) and logarithmic transformation was applied for visual assessment of image quality, plotting profile across the center of the images and calculating full width at half maximum (FWHM) in horizontal and vertical directions. The geometric, penetration, and scatter at 140 keV for low-energy general-purpose were 93.20%, 4.13%, 2.67% respectively. Similarly, geometric, penetration, and scatter at 140 keV for low-energy high-resolution (LEHR), medium-energy general-purpose (MEGP), and high-energy general-purpose (HEGP) collimator were (94.06%, 3.39%, 2.55%), (96.42%, 1.52%, 2.06%), and (96.70%, 1.45%, 1.85%), respectively. For MEGP collimator at 245 keV photon and for HEGP collimator at 364 keV were 89.10%, 7.08%, 3.82% and 67.78%, 18.63%, 13.59%, respectively. Low-energy general-purpose and LEHR collimator is best to image 140 keV photon. HEGP can be used for 245 keV and 364 keV; however, correction for penetration and scatter must be applied if one is interested to quantify the in vivo activity of energy 364 keV. Due to heavy penetration and scattering, 511 keV photons should not be imaged with HEGP collimator

  18. Early versus late Gamma Knife radiosurgery following transsphenoidal surgery for nonfunctioning pituitary macroadenomas: a multicenter matched-cohort study.

    Science.gov (United States)

    Pomeraniec, I Jonathan; Kano, Hideyuki; Xu, Zhiyuan; Nguyen, Brandon; Siddiqui, Zaid A; Silva, Danilo; Sharma, Mayur; Radwan, Hesham; Cohen, Jonathan A; Dallapiazza, Robert F; Iorio-Morin, Christian; Wolf, Amparo; Jane, John A; Grills, Inga S; Mathieu, David; Kondziolka, Douglas; Lee, Cheng-Chia; Wu, Chih-Chun; Cifarelli, Christopher P; Chytka, Tomas; Barnett, Gene H; Lunsford, L Dade; Sheehan, Jason P

    2017-10-27

    OBJECTIVE Gamma Knife radiosurgery (GKRS) is frequently used to treat residual or recurrent nonfunctioning pituitary macroadenomas. There is no consensus as to whether GKRS should be used early after surgery or if radiosurgery should be withheld until there is evidence of imaging-defined progression of tumor. Given the high incidence of adenoma progression after subtotal resection over time, the present study intended to evaluate the effect of timing of radiosurgery on outcome. METHODS This is a multicenter retrospective review of patients with nonfunctioning pituitary macroadenomas who underwent transsphenoidal surgery followed by GKRS from 1987 to 2015 at 9 institutions affiliated with the International Gamma Knife Research Foundation. Patients were matched by adenoma and radiosurgical parameters and stratified based on the interval between last resection and radiosurgery. Operative results, imaging data, and clinical outcomes were compared across groups following early (≤ 6 months after resection) or late (> 6 months after resection) radiosurgery. RESULTS After matching, 222 patients met the authors' study criteria (from an initial collection of 496 patients) and were grouped based on early (n = 111) or late (n = 111) GKRS following transsphenoidal surgery. There was a greater risk of tumor progression after GKRS (p = 0.013) and residual tumor (p = 0.038) in the late radiosurgical group over a median imaging follow-up period of 68.5 months. No significant difference in the occurrence of post-GKRS endocrinopathy was observed (p = 0.68). Thirty percent of patients without endocrinopathy in the early cohort developed new endocrinopathies during the follow-up period versus 27% in the late cohort (p = 0.84). Fourteen percent of the patients in the early group and 25% of the patients in the late group experienced the resolution of endocrine dysfunction after original presentation (p = 0.32). CONCLUSIONS In this study, early GKRS was associated with a lower risk of

  19. The results of gamma knife radiosurgery for malignant skull base tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Takayuki; Kobayashi, Tatsuya; Kida, Yoshihisa; Oyama, Hirofumi; Niwa, Masahiro [Komaki City Hospital, Aichi (Japan)

    1996-03-01

    The results of gamma knife radiosurgery for malignant skull base tumors were analyzed using repeated magnetic resonance imagings and neurological examinations. Nineteen malignant skull base tumors were treated and followed up for 22.3 months (5-40 months) using MR imagings. The mean age was 54.4 years old (ranging from 16-85). Ten were male and 9 were female. Prior to the radiosurgery, removal of the tumors in 17 cases, conventional radiation therapy in 7, and chemotherapy in 4 etc. were performed. The pathological diagnoses were chordoma in 6 patients, metastatic tumors in 5, epipharyngeal carcinoma in 2, adenoid cystic carcinoma in 2, and others in 4. The locations of tumors were clivus in 8, parasellar region in 5, epipharynx in 2, paranasal sinus in 2, C-P angle in 1, and intraorbital region in 1 (14 intracranial and 5 extracranial). The mean diameter of the tumor was 33.5 mm. The mean maximum dose was 26.8 Gy and the mean marginal dose was 12.9 Gy during treatment. Repeated MR imagings revealed decrease of tumor size in 12 cases, showing no change in 1, and increase of tumor size in 5 (unknown in 1). Follow-up neurological examinations showed improvement in 3 patients, no change in 9, and deterioration in 7. There were 11 deaths during a mean follow-up period of 17.8 months (5-32 months) and another 8 cases are alive for a mean follow-up of 30.5 months (20-40 months) after the radiosurgery. Although the tumor size was large at the time of treatment, the results of gamma knife radiosurgery were promising. Considering the quality of life of patients with malignant skull base tumors, it is emphasized that gamma knife treatment is the method of choice compared with radical removal of the tumors. (author).

  20. [Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].

    Science.gov (United States)

    Furdová, A; Furdová, Ad; Thurzo, A; Šramka, M; Chorvát, M; Králik, G

    Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing technology possibilities in ophthalmology. It is focusing on innovative implementation of eye tumors treatment planning in stereotactic radiosurgery irradiation.We analyze our first experience with 3D printing model of the eye in intraocular tumor planning stereotactic radiosurgery. 3D printing, model, Fused Deposition Modelling, stereotactic radiosurgery, prostheses, intraocular tumor.

  1. Linear Accelerator-Based Radiosurgery Alone for Arteriovenous Malformation: More Than 12 Years of Observation

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Takayuki, E-mail: takayuki@nagasaki-u.ac.jp; Kamada, Kensaku; Izumo, Tsuyoshi; Hayashi, Nobuyuki; Nagata, Izumi

    2014-07-01

    Purpose: Although radiosurgery is an accepted treatment method for intracranial arteriovenous malformations (AVMs), its long-term therapeutic effects have not been sufficiently evaluated, and many reports of long-term observations are from gamma-knife facilities. Furthermore, there are few reported results of treatment using only linear accelerator (LINAC)-based radiosurgery (LBRS). Methods and Materials: Over a period of more than 12 years, we followed the long-term results of LBRS treatment performed in 51 AVM patients. Results: The actuarial obliteration rates, after a single radiosurgery session, at 3, 5, 10, and 15 years were 46.9%, 54.0%, 64.4%, and 68.0%, respectively; when subsequent radiosurgeries were included, the rates were 46.9%, 61.3%, 74.2%, and 90.3%, respectively. Obliteration rates were significantly related to target volumes ≥4 cm{sup 3}, marginal doses ≥12 Gy, Spetzler-Martin grades (1 vs other), and AVM scores ≥1.5; multivariate analyses revealed a significant difference for target volumes ≥4 cm{sup 3}. The postprocedural actuarial symptomatic radiation injury rates, after a single radiation surgery session, at 5, 10, and 15 years were 12.3%, 16.8%, and 19.1%, respectively. Volumes ≥4 cm{sup 3}, location (lobular or other), AVM scores ≥1.5, and the number of radiosurgery were related to radiation injury incidence; multivariate analyses revealed significant differences associated with volumes ≥4 cm{sup 3} and location (lobular or other). Conclusions: Positive results can be obtained with LBRS when performed with a target volume ≤4 cm{sup 3}, an AVM score ≤1.5, and ≥12 Gy radiation. Bleeding and radiation injuries may appear even 10 years after treatment, necessitating long-term observation.

  2. Cone beam computed tomography image guidance system for a dedicated intracranial radiosurgery treatment unit.

    Science.gov (United States)

    Ruschin, Mark; Komljenovic, Philip T; Ansell, Steve; Ménard, Cynthia; Bootsma, Gregory; Cho, Young-Bin; Chung, Caroline; Jaffray, David

    2013-01-01

    Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210° of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. NRMC - A GPU code for N-Reverse Monte Carlo modeling of fluids in confined media

    Science.gov (United States)

    Sánchez-Gil, Vicente; Noya, Eva G.; Lomba, Enrique

    2017-08-01

    NRMC is a parallel code for performing N-Reverse Monte Carlo modeling of fluids in confined media [V. Sánchez-Gil, E.G. Noya, E. Lomba, J. Chem. Phys. 140 (2014) 024504]. This method is an extension of the usual Reverse Monte Carlo method to obtain structural models of confined fluids compatible with experimental diffraction patterns, specifically designed to overcome the problem of slow diffusion that can appear under conditions of tight confinement. Most of the computational time in N-Reverse Monte Carlo modeling is spent in the evaluation of the structure factor for each trial configuration, a calculation that can be easily parallelized. Implementation of the structure factor evaluation in NVIDIA® CUDA so that the code can be run on GPUs leads to a speed up of up to two orders of magnitude.

  4. Imaging of arteriovenous malformation following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Tranchida, J.V.; Mehall, C.J.; Slovis, T.L.; Lis-Planells, M.

    1997-01-01

    Background. Stereotactic radiosurgery allows for a high dose of focused radiation to be delivered to a small lesion such as an arteriovenous malformation (AVM). The clinical change and brain response over time to this localized high-dose radiation can be quite striking. Objective. The objective of this study to describe and analyse the imaging changes following radiotherapy for AVMs. Materials and methods. The clinical presentation and the imaging changes following radiotherapy in two patients were studied over the course of 1-2 years. Results. The imaging findings include diffuse low attenuation and contrast enhancement on CT. High-signal lesions were apparent on T2-weighted MR images with prominent contrast enhancement on T1-weighted images. Ring enhancement occurred over time. While new changes appeared over 12 months, these changes diminished during the second year. Conclusion. Radiotherapy induces inflammatory changes that are generally reversible but can lead to parenchymal destruction. These imaging changes are often nonspecific and therefore must be interpreted in light of clinical symptomatology and the time course since treatment. These patients should receive routine MR imaging within 3 months after radiosurgery with follow-up imaging at 6, 12, and 18 months. (orig.). With 8 figs

  5. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  6. Analysis of communication costs for domain decomposed Monte Carlo methods in nuclear reactor analysis

    International Nuclear Information System (INIS)

    Siegel, A.; Smith, K.; Fischer, P.; Mahadevan, V.

    2012-01-01

    A domain decomposed Monte Carlo communication kernel is used to carry out performance tests to establish the feasibility of using Monte Carlo techniques for practical Light Water Reactor (LWR) core analyses. The results of the prototype code are interpreted in the context of simplified performance models which elucidate key scaling regimes of the parallel algorithm.

  7. Efficient assignment of the temperature set for Parallel Tempering

    International Nuclear Information System (INIS)

    Guidetti, M.; Rolando, V.; Tripiccione, R.

    2012-01-01

    We propose a simple algorithm able to identify a set of temperatures for a Parallel Tempering Monte Carlo simulation, that maximizes the probability that the configurations drift across all temperature values, from the coldest to the hottest ones, and vice versa. The proposed algorithm starts from data gathered from relatively short Monte Carlo simulations and is straightforward to implement. We assess its effectiveness on a test case simulation of an Edwards–Anderson spin glass on a lattice of 12 3 sites.

  8. Linear accelerator stereotactic radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Varela-Lema, Leonor; Lopez-Garcia, Marisa; Maceira-Rozas, Maria; Munoz-Garzon, Victor

    2015-01-01

    Stereotactic radiosurgery is accepted as an alternative for patients with refractory trigeminal neuralgia, but existing evidence is fundamentally based on the Gamma Knife, which is a specific device for intracranial neurosurgery, available in few facilities. Over the last decade it has been shown that the use of linear accelerators can achieve similar diagnostic accuracy and equivalent dose distribution. To assess the effectiveness and safety of linear-accelerator stereotactic radiosurgery for the treatment of patients with refractory trigeminal neuralgia. We carried out a systematic search of the literature in the main electronic databases (PubMed, Embase, ISI Web of Knowledge, Cochrane, Biomed Central, IBECS, IME, CRD) and reviewed grey literature. All original studies on the subject published in Spanish, French, English, and Portuguese were eligible for inclusion. The selection and critical assessment was carried out by 2 independent reviewers based on pre-defined criteria. In view of the impossibility of carrying out a pooled analysis, data were analyzed in a qualitative way. Eleven case series were included. In these, satisfactory pain relief (BIN I-IIIb or reduction in pain = 50) was achieved in 75% to 95.7% of the patients treated. The mean time to relief from pain ranged from 8.5 days to 3.8 months. The percentage of patients who presented with recurrences after one year of follow-up ranged from 5% to 28.8%. Facial swelling or hypoesthesia, mostly of a mild-moderate grade appeared in 7.5% - 51.9% of the patients. Complete anaesthesia dolorosa was registered in only study (5.3%). Cases of hearing loss (2.5%), brainstem edema (5.8%), and neurotrophic keratoplasty (3.5%) were also isolated. The results suggest that stereotactic radiosurgery with linear accelerators could constitute an effective and safe therapeutic alternative for drug-resistant trigeminal neuralgia. However, existing studies leave important doubts as to optimal treatment doses or the

  9. A cerebral arteriovenous malformation grading system for gamma knife radiosurgery with the aim of early obliteration

    International Nuclear Information System (INIS)

    Negishi, Masatoshi; Inoue, Hiroshi K.; Hirato, Masafumi; Yokoe, Takao; Iino, Yuichi; Ohye, Chihiro; Shibazaki, Tohru

    1998-01-01

    Bleeding in the latency period before obliteration considerably worsens the prognosis of cerebral arteriovenous malformations (AVMs). Bleeding risk should be considered and total obliteration should performed as early as possible. In this study we investigated factors related to early obliteration following Gamma Knife radiosurgery and proposed a grading system for AVMs. Forty-six patients with cerebral AVMs followed angiographically within twelve months after Gamma Knife radiosurgery were analyzed. Four factors, volume, type (categorized by our own method), location, and marginal dose were found to be correlated with early obliteration rate. We scored these factors, and categorized the scores into a grade O to 6 Gamma Knife Score (GKS), and evaluated the obliteration rate of each grade. The total obliteration rate in twelve months according to grade was: grades 0 and 1, 61.9%; grades 2 and 3, 36.0%, grades 4 and 5, 16.7%. AVMs with a low GKS (grades 0 and 1) had a high early obliteration rate and seemed suitable for Gamma Knife radiosurgery. Since early obliteration is difficult to obtain in the high grade group, endovascular surgery should be considered to reduce the GKS before Gamma Knife radiosurgery. (author)

  10. Development of a Prototype Robotic System for Radiosurgery with Upper Hemispherical Workspace

    Directory of Open Access Journals (Sweden)

    Sun Young Noh

    2017-01-01

    Full Text Available This paper introduces a specialized robotic system under development for radiosurgery using a small-sized linear accelerator. The robotic system is a 5-DOF manipulator that can be installed above a patient to make an upper hemispherical workspace centered in a target point. In order to determine the optimal lengths of the link, we consider the requirements for the workspace of a linear accelerator for radiosurgery. A more suitable kinematic structure than conventional industrial manipulators is proposed, and the kinematic analysis is also provided. A graphic simulator is implemented and used for dynamic analysis. Based on those results, a prototype manipulator and its control system are under development.

  11. WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

    International Nuclear Information System (INIS)

    Schlesinger, D.

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  12. WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, D. [University of Virginia Health Systems (United States)

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  13. Molecular Monte Carlo Simulations Using Graphics Processing Units: To Waste Recycle or Not?

    Science.gov (United States)

    Kim, Jihan; Rodgers, Jocelyn M; Athènes, Manuel; Smit, Berend

    2011-10-11

    In the waste recycling Monte Carlo (WRMC) algorithm, (1) multiple trial states may be simultaneously generated and utilized during Monte Carlo moves to improve the statistical accuracy of the simulations, suggesting that such an algorithm may be well posed for implementation in parallel on graphics processing units (GPUs). In this paper, we implement two waste recycling Monte Carlo algorithms in CUDA (Compute Unified Device Architecture) using uniformly distributed random trial states and trial states based on displacement random-walk steps, and we test the methods on a methane-zeolite MFI framework system to evaluate their utility. We discuss the specific implementation details of the waste recycling GPU algorithm and compare the methods to other parallel algorithms optimized for the framework system. We analyze the relationship between the statistical accuracy of our simulations and the CUDA block size to determine the efficient allocation of the GPU hardware resources. We make comparisons between the GPU and the serial CPU Monte Carlo implementations to assess speedup over conventional microprocessors. Finally, we apply our optimized GPU algorithms to the important problem of determining free energy landscapes, in this case for molecular motion through the zeolite LTA.

  14. Parallel computation of nondeterministic algorithms in VLSI

    Energy Technology Data Exchange (ETDEWEB)

    Hortensius, P D

    1987-01-01

    This work examines parallel VLSI implementations of nondeterministic algorithms. It is demonstrated that conventional pseudorandom number generators are unsuitable for highly parallel applications. Efficient parallel pseudorandom sequence generation can be accomplished using certain classes of elementary one-dimensional cellular automata. The pseudorandom numbers appear in parallel on each clock cycle. Extensive study of the properties of these new pseudorandom number generators is made using standard empirical random number tests, cycle length tests, and implementation considerations. Furthermore, it is shown these particular cellular automata can form the basis of efficient VLSI architectures for computations involved in the Monte Carlo simulation of both the percolation and Ising models from statistical mechanics. Finally, a variation on a Built-In Self-Test technique based upon cellular automata is presented. These Cellular Automata-Logic-Block-Observation (CALBO) circuits improve upon conventional design for testability circuitry.

  15. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  16. Single-session Gamma Knife radiosurgery for optic pathway/hypothalamic gliomas.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2016-12-01

    OBJECTIVE Because of their critical and central location, it is deemed necessary to fractionate when considering irradiating optic pathway/hypothalamic gliomas. Stereotactic fractionated radiotherapy is considered safer when dealing with gliomas in this location. In this study, the safety and efficacy of single-session stereotactic radiosurgery for optic pathway/hypothalamic gliomas were reviewed. METHODS Between December 2004 and June 2014, 22 patients with optic pathway/hypothalamic gliomas were treated by single-session Gamma Knife radiosurgery. Twenty patients were available for follow-up for a minimum of 1 year after treatment. The patients were 5 to 43 years (median 16 years) of age. The tumor volume was 0.15 to 18.2 cm 3 (median 3.1 cm 3 ). The prescription dose ranged from 8 to 14 Gy (median 11.5 Gy). RESULTS The mean follow-up period was 43 months. Five tumors involved the optic nerve only, and 15 tumors involved the chiasm/hypothalamus. Two patients died during the follow-up period. The tumors shrank in 12 cases, remained stable in 6 cases, and progressed in 2 cases, thereby making the tumor control rate 90%. Vision remained stable in 12 cases, improved in 6 cases, and worsened in 2 cases in which there was tumor progression. Progression-free survival was 83% at 3 years. CONCLUSIONS The initial results indicate that single-session Gamma Knife radiosurgery is a safe and effective treatment option for optic pathway/hypothalamic gliomas.

  17. Long-Term Results of Gamma Knife Radiosurgery for Intracranial Meningioma.

    Science.gov (United States)

    Jang, Chang Ki; Jung, Hyun Ho; Chang, Jong Hee; Chang, Jin Woo; Park, Yong Gou; Chang, Won Seok

    2015-10-01

    The predominant treatment modality for meningioma is surgical resection. However, gamma knife radiosurgery is also an important treatment modality for meningioma that is small or cannot be completely removed because of its location. In this study, we evaluated the effectiveness and long-term results of radiosurgical treatment for meningioma in our institution. We studied 628 patients (130 men and 498 women) who underwent gamma knife radiosurgery for intracranial meningioma, which is radiologically diagnosed, from Jan 2008 to Nov 2012. We included patients with single lesion meningioma, and followed up after 6 months with imaging, and then at 24 months with a clinical examination. Patients with high-grade meningioma or multiple meningiomas were excluded. We analyzed each of the factors associated with progression free survival. The median patient's age was 56.8 years. Maximal dosage was 27.8 Gy and marginal dosage was 13.9 Gy. The overall tumor control rate was 95%. Twenty-eight patients (4.4%) showed evidence of tumor recurrence. Ninety-eight patients (15%) developed peritumoral edema (PTE) after gamma-knife surgery; two of them (2%) underwent surgical resections due to PTE. Nine patients had craniotomy and tumor removal after gamma knife surgery. Gamma knife surgery for intracranial meningioma has proven to be a safe and effective treatment tool with successful long-term outcomes. Gamma knife radiosurgery can be especially effective in cases of remnant meningioma after surgical resection or where PTE is not present.

  18. Utility and limitation of radiosurgery for metastatic brain tumors

    International Nuclear Information System (INIS)

    Kagawa, Kota; Kiya, Katsuzo; Satoh, Hideki; Mizoue, Tatsuya; Matsushige, Toshinori; Araki, Hayato; Akimitsu, Tomohide

    2003-01-01

    The purpose of this study was to evaluate the utility and limitations of radiosurgery for metastatic brain lesions, and to compare the clinical results of stereotactic radiosurgery (SRS) with those of whole-brain radiation therapy (WBRT) in 45 patients with metastatic brain tumors. The patients were divided into two groups: the SRS group (22 patients) and the WBRT group (23 patients). Mean survival was not significantly different between the two groups. However, in patients with 6 or more lesions, both survival time and recurrence-free time in the SRS group were inferior to those in the WBRT group. The main complication in the SRS group was perifocal edema, while dementia was seen in the WBRT group. The bedridden period was longer in the WBRT group than in the SRS group. Death caused by brain lesions was rare in both groups. From these results, SRS preserves high quality of life longer than WBRT, but SRS should be cautiously used in patients with 6 or more lesions. (author)

  19. Vector and parallel processors in computational science

    International Nuclear Information System (INIS)

    Duff, I.S.; Reid, J.K.

    1985-01-01

    This book presents the papers given at a conference which reviewed the new developments in parallel and vector processing. Topics considered at the conference included hardware (array processors, supercomputers), programming languages, software aids, numerical methods (e.g., Monte Carlo algorithms, iterative methods, finite elements, optimization), and applications (e.g., neutron transport theory, meteorology, image processing)

  20. SU-E-T-669: Radiosurgery Failure for Trigeminal Neuralgia: A Study of Radiographic Spatial Fidelity

    Energy Technology Data Exchange (ETDEWEB)

    Howe, J [Associates In Medical Physics, Louisville, KY (United States); Spalding, A [Norton Cancer Institute, Louisville, Kentucky (United States)

    2015-06-15

    Purpose: Management of Trigeminal Neuralgia with radiosurgery is well established, but often met with limited success. Recent advancements in imaging afford improvements in target localization for radiosurgery. Methods: A Trigeminal Neuralgia radiosurgery specific protocol was established for MR enhancement of the trigeminal nerve using a CISS scan with slice spacing of 0.7mm. Computed Tomography simulation was performed using axial slices on a 40 slice CT with slice spacing of 0.6mm. These datasets were registered using a mutual information algorithm and localized in a stereotactic coordinate system. Image registration between the MR and CT was evaluated for each patient by a Medical Physicist to ensure accuracy. The dorsal root entry zone target was defined on the CISS MR by a Neurosurgeon and dose calculations performed on the localized CT. Treatment plans were reviewed and approved by a Radiation Oncologist and Neurosurgeon. Image guided radiosurgery was delivered using positioning tolerance of 0.5mm and 1°. Eight patients with Trigeminal Neuralgia were treated with this protocol. Results: Seven patients reported a favorable response to treatment with average Barrow Neurological Index pain score of four before treatment and one following treatment. Only one patient had a BNI>1 following treatment and review of the treatment plan revealed that the CISS MR was registered to the CT via a low resolution (5mm slice spacing) T2 MR. All other patients had CISS MR registered directly with the localized CT. This patient was retreated 6 months later using direct registration between CISS MR and localized CT and subsequently responded to treatment with a BNI of one. Conclusion: Frameless radiosurgery offers an effective solution to Trigeminal Neuralgia management provided appropriate technology and imaging protocols (utilizing submillimeter imaging) are established and maintained.

  1. SU-E-T-669: Radiosurgery Failure for Trigeminal Neuralgia: A Study of Radiographic Spatial Fidelity

    International Nuclear Information System (INIS)

    Howe, J; Spalding, A

    2015-01-01

    Purpose: Management of Trigeminal Neuralgia with radiosurgery is well established, but often met with limited success. Recent advancements in imaging afford improvements in target localization for radiosurgery. Methods: A Trigeminal Neuralgia radiosurgery specific protocol was established for MR enhancement of the trigeminal nerve using a CISS scan with slice spacing of 0.7mm. Computed Tomography simulation was performed using axial slices on a 40 slice CT with slice spacing of 0.6mm. These datasets were registered using a mutual information algorithm and localized in a stereotactic coordinate system. Image registration between the MR and CT was evaluated for each patient by a Medical Physicist to ensure accuracy. The dorsal root entry zone target was defined on the CISS MR by a Neurosurgeon and dose calculations performed on the localized CT. Treatment plans were reviewed and approved by a Radiation Oncologist and Neurosurgeon. Image guided radiosurgery was delivered using positioning tolerance of 0.5mm and 1°. Eight patients with Trigeminal Neuralgia were treated with this protocol. Results: Seven patients reported a favorable response to treatment with average Barrow Neurological Index pain score of four before treatment and one following treatment. Only one patient had a BNI>1 following treatment and review of the treatment plan revealed that the CISS MR was registered to the CT via a low resolution (5mm slice spacing) T2 MR. All other patients had CISS MR registered directly with the localized CT. This patient was retreated 6 months later using direct registration between CISS MR and localized CT and subsequently responded to treatment with a BNI of one. Conclusion: Frameless radiosurgery offers an effective solution to Trigeminal Neuralgia management provided appropriate technology and imaging protocols (utilizing submillimeter imaging) are established and maintained

  2. Gamma Knife radiosurgery for hemangioma of the cavernous sinus.

    Science.gov (United States)

    Lee, Cheng-Chia; Sheehan, Jason P; Kano, Hideyuki; Akpinar, Berkcan; Martinez-Alvarez, Roberto; Martinez-Moreno, Nuria; Guo, Wan-Yuo; Lunsford, L Dade; Liu, Kang-Du

    2017-05-01

    OBJECTIVE Cavernous sinus hemangiomas (CSHs) are rare vascular tumors. A direct microsurgical approach usually results in massive hemorrhage and incomplete tumor resection. Although stereotactic radiosurgery (SRS) has emerged as a therapeutic alternative to microsurgery, outcome studies are few. Authors of the present study evaluated the role of SRS for CSH. METHODS An international multicenter study was conducted to review outcome data in 31 patients with CSH. Eleven patients had initial microsurgery before SRS, and the other 20 patients (64.5%) underwent Gamma Knife SRS as the primary management for their CSH. Median age at the time of radiosurgery was 47 years, and 77.4% of patients had cranial nerve dysfunction before SRS. Patients received a median tumor margin dose of 12.6 Gy (range 12-19 Gy) at a median isodose of 55%. RESULTS Tumor regression was confirmed by imaging in all 31 patients, and all patients had greater than 50% reduction in tumor volume at 6 months post-SRS. No patient had delayed tumor growth, new cranial neuropathy, visual function deterioration, adverse radiation effects, or hypopituitarism after SRS. Twenty-four patients had presented with cranial nerve disorders before SRS, and 6 (25%) of them had gradual improvement. Four (66.7%) of the 6 patients with orbital symptoms had symptomatic relief at the last follow-up. CONCLUSIONS Stereotactic radiosurgery was effective in reducing the volume of CSH and attaining long-term tumor control in all patients at a median of 40 months. The authors' experience suggests that SRS is a reasonable primary and adjuvant treatment modality for patients in whom a CSH is diagnosed.

  3. Gamma radiosurgery combined with trans-sphenoidal surgery for pituitary tumor involved to the cavernous sinus

    International Nuclear Information System (INIS)

    Ikeda, Hidetoshi; Yoshimoto, Takashi; Shirokura, Hidefumi.

    1995-01-01

    Ten patients (2 males and 8 females with an average age of 39 years) were treated with combined trans-sphenoidal surgery and gamma radiosurgery for pituitary tumor involved to the cavernous sinus. A Follow-up period ranged from 7 to 29 months, with a mean of 21 months. Therapeutic effects were assessed using magnetic resonance imaging (MRI) every 3 months, endocrine examination, optical examination for visual field, and auditory test. Pituitary tumor after radiosurgery was shown as hypointensity on T1-weighted images and hyperintensity on T2-weighted images. Tumor response could be classified on MRI into (1) a remarkably decreased tumor in size with increased contrast enhancement (n=6), (2) a remarkably decreased tumor in size with unchanged contrast enhancement (n=one), (3) a slightly decreased tumor in size with increased spotted contrast enhancement (n=2), and (4) unchanged tumor in size with decreased contrast enhancement (n=one). Of 6 Type 1 patients, 5 had growth hormone production. Growth hormone production tended to be associated with favorable response to radiosurgery. In 3 patients who showed endocrinologically favorable response (such as increased growth hormone in blood and somatomedin C value), complete regression of tumor was achieved at a 20-month follow-up period. Radiosurgery also seemed to be useful for treating hormone active tumors. (N.K.)

  4. Portable parallel programming in a Fortran environment

    International Nuclear Information System (INIS)

    May, E.N.

    1989-01-01

    Experience using the Argonne-developed PARMACs macro package to implement a portable parallel programming environment is described. Fortran programs with intrinsic parallelism of coarse and medium granularity are easily converted to parallel programs which are portable among a number of commercially available parallel processors in the class of shared-memory bus-based and local-memory network based MIMD processors. The parallelism is implemented using standard UNIX (tm) tools and a small number of easily understood synchronization concepts (monitors and message-passing techniques) to construct and coordinate multiple cooperating processes on one or many processors. Benchmark results are presented for parallel computers such as the Alliant FX/8, the Encore MultiMax, the Sequent Balance, the Intel iPSC/2 Hypercube and a network of Sun 3 workstations. These parallel machines are typical MIMD types with from 8 to 30 processors, each rated at from 1 to 10 MIPS processing power. The demonstration code used for this work is a Monte Carlo simulation of the response to photons of a ''nearly realistic'' lead, iron and plastic electromagnetic and hadronic calorimeter, using the EGS4 code system. 6 refs., 2 figs., 2 tabs

  5. Monte Carlo MP2 on Many Graphical Processing Units.

    Science.gov (United States)

    Doran, Alexander E; Hirata, So

    2016-10-11

    In the Monte Carlo second-order many-body perturbation (MC-MP2) method, the long sum-of-product matrix expression of the MP2 energy, whose literal evaluation may be poorly scalable, is recast into a single high-dimensional integral of functions of electron pair coordinates, which is evaluated by the scalable method of Monte Carlo integration. The sampling efficiency is further accelerated by the redundant-walker algorithm, which allows a maximal reuse of electron pairs. Here, a multitude of graphical processing units (GPUs) offers a uniquely ideal platform to expose multilevel parallelism: fine-grain data-parallelism for the redundant-walker algorithm in which millions of threads compute and share orbital amplitudes on each GPU; coarse-grain instruction-parallelism for near-independent Monte Carlo integrations on many GPUs with few and infrequent interprocessor communications. While the efficiency boost by the redundant-walker algorithm on central processing units (CPUs) grows linearly with the number of electron pairs and tends to saturate when the latter exceeds the number of orbitals, on a GPU it grows quadratically before it increases linearly and then eventually saturates at a much larger number of pairs. This is because the orbital constructions are nearly perfectly parallelized on a GPU and thus completed in a near-constant time regardless of the number of pairs. In consequence, an MC-MP2/cc-pVDZ calculation of a benzene dimer is 2700 times faster on 256 GPUs (using 2048 electron pairs) than on two CPUs, each with 8 cores (which can use only up to 256 pairs effectively). We also numerically determine that the cost to achieve a given relative statistical uncertainty in an MC-MP2 energy increases as O(n 3 ) or better with system size n, which may be compared with the O(n 5 ) scaling of the conventional implementation of deterministic MP2. We thus establish the scalability of MC-MP2 with both system and computer sizes.

  6. WE-G-BRA-08: Failure Modes and Effects Analysis (FMEA) for Gamma Knife Radiosurgery

    International Nuclear Information System (INIS)

    Xu, Y; Bhatnagar, J; Bednarz, G; Flickinger, J; Arai, Y; Huq, M Saiful; Vacsulka, J; Monaco, E; Niranjan, A; Lunsford, L Dade; Feng, W

    2015-01-01

    Purpose: To perform a failure modes and effects analysis (FMEA) study for Gamma Knife (GK) radiosurgery processes at our institution based on our experience with the treatment of more than 13,000 patients. Methods: A team consisting of medical physicists, nurses, radiation oncologists, neurosurgeons at the University of Pittsburgh Medical Center and an external physicist expert was formed for the FMEA study. A process tree and a failure mode table were created for the GK procedures using the Leksell GK Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection (D) for failure modes were assigned to each failure mode by each professional on a scale from 1 to 10. The risk priority number (RPN) for each failure mode was then calculated (RPN = OxSxD) as the average scores from all data sets collected. Results: The established process tree for GK radiosurgery consists of 10 sub-processes and 53 steps, including a sub-process for frame placement and 11 steps that are directly related to the frame-based nature of the GK radiosurgery. Out of the 86 failure modes identified, 40 failure modes are GK specific, caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the GK helmets and plugs, and the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all radiation therapy techniques. The failure modes with the highest hazard scores are related to imperfect frame adaptor attachment, bad fiducial box assembly, overlooked target areas, inaccurate previous treatment information and excessive patient movement during MRI scan. Conclusion: The implementation of the FMEA approach for Gamma Knife radiosurgery enabled deeper understanding of the overall process among all professionals involved in the care of the patient and helped identify potential

  7. An improved tracking framework for ultrasound probe localization in image-guided radiosurgery

    Directory of Open Access Journals (Sweden)

    Ipsen Svenja

    2016-09-01

    Full Text Available Real-time target localization with ultrasound holds high potential for image guidance and motion compensation in radiosurgery due to its non-invasive image acquisition free from ionizing radiation. However, a two-step localization has to be performed when integrating ultrasound into the existing radiosurgery workflow. In addition to target localization inside the ultrasound volume, the probe itself has to be localized in order to transform the target position into treatment room coordinates. By adapting existing camera calibration tools, we have developed a method to extend the stereoscopic X-ray tracking system of a radiosurgery platform in order to locate objects such as marker geometries with six degrees of freedom. The calibration was performed with 0.1 mm reprojection error. By using the full area of the flat-panel detectors without pre-processing the extended software increased the tracking volume and resolution by up to 80%, substantially improving patient localization and marker detectability. Furthermore, marker-tracking showed sub-millimeter accuracy and rotational errors below 0.1°. This demonstrates that the developed extension framework can accurately localize marker geometries using an integrated X-ray system, establishing the link for the integration of real-time ultrasound image guidance into the existing system.

  8. Risk factors for local failure requiring salvage neurosurgery after radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Weltman, Eduardo; Hanriot, Rodrigo de Morais; Prisco, Flavio Eduardo; Nadalin, Wladimir; Brandt, Reynaldo Andre; Moreira, Frederico Rafael

    2004-01-01

    Objective: the aim of this study is to select the risk factors for local failure requiring salvage neurosurgery in patients with brain metastases treated with stereotactic radiosurgery in a single institution. Methods: the follow-up of 123 patients, with 255 brain metastases treated with radiosurgery at the Radiation Oncology Department of the Hospital Israelita Albert Einstein from July 1993 to August 2001, was retrospectively analyzed. The criteria for salvage neurosurgery were tumor volume enlargement, or tumor persistence leading to severe neurological symptoms, life threatening situation or critical steroid dependence. We considered the case as local failure when the histopathologic evaluation showed morphologically preserved cancer cells (tumor recurrence, persistence or progression). We applied the Fisher's exact test to evaluate the statistical correlation between local failure and primary tumor histology, volume of the brain metastases, prescribed radiosurgery dose, and whole brain radiotherapy. Results: fourteen of 123 patients (11%) underwent salvage neurosurgery. Histology showed preserved cancer cells with necrosis and/or bleeding in 11 cases (9% of the total accrual), and only necrosis with or without bleeding (without preserved cancer cells) in three cases. The primary tumor histology among the 11 patients considered with active neoplasia was malignant melanoma in five cases (21% of the patients with melanoma), breast adenocarcinoma in three (16% of the patients with breast cancer), and other histology in the remaining three. Breast cancer diagnosis, non-elective whole brain irradiation, volume of the brain metastases, and the prescribed radiosurgery dose did not correlate with the risk of local failure. Patients treated with elective whole brain radiotherapy showed fewer local failures, when compared to all patients receiving whole brain radiotherapy, and to the patients not receiving this treatment, with incidence of failure in 4%,7% and 14

  9. Gamma knife radiosurgery for acoustic neurinomas. Pt. 1. The analysis of tumor control

    International Nuclear Information System (INIS)

    Fukuoka, Seiji; Seo, Yoshinobu; Nakagawara, Jyoji

    1997-01-01

    Forty-three patients with the unilateral type of acoustic neurinoma who were treated with gamma knife radiosurgery were analyzed from the viewpoint of tumor control. The follow-up period ranged from 22 to 55 months. The tumors were treated with marginal radiation doses of 9-15 Gy with multiple isocenters. The actuarial tumor reduction rates were 42% at one year, 75% at 2 years, and 92% at 3 years after gamma knife radiosurgery. Transient tumor expansion was seen in 33% of patients, which correlated with previous surgical cases. The present control rate was 91%. SPECT was performed on 15 selected patients before and 1 year and 2 years after gamma knife radiosurgery. 201 TlCl SPECT was used to determine tumor viability, and the early and delayed 99m Tc-DTPA-HSA-D SPECT images were used to assess tumor vascularity and permeability, respectively. The Tl index and HSA-D index of the delayed images were not significantly different from the respective preoperative values. However, there was a statistically significant decrease in the HSA-D index of the early images 1 year after treatment. A statistically significant reduction in tumor volume was seen 2 years after treatment in these 15 patients, meaning that a reduction in tumor vascularity was followed by a reduction in tumor size. One patient underwent surgical excision of the tumor 18 months after gamma knife radiosurgery because the tumor had expanded and resulted in cerebellar ataxia. Histopathologic investigation revealed the presence of some tumor cells with irregularly shaped nuclei and marked intimal thickening or obliteration of the tumor vessels. (K.H.)

  10. Study on random number generator in Monte Carlo code

    International Nuclear Information System (INIS)

    Oya, Kentaro; Kitada, Takanori; Tanaka, Shinichi

    2011-01-01

    The Monte Carlo code uses a sequence of pseudo-random numbers with a random number generator (RNG) to simulate particle histories. A pseudo-random number has its own period depending on its generation method and the period is desired to be long enough not to exceed the period during one Monte Carlo calculation to ensure the correctness especially for a standard deviation of results. The linear congruential generator (LCG) is widely used as Monte Carlo RNG and the period of LCG is not so long by considering the increasing rate of simulation histories in a Monte Carlo calculation according to the remarkable enhancement of computer performance. Recently, many kinds of RNG have been developed and some of their features are better than those of LCG. In this study, we investigate the appropriate RNG in a Monte Carlo code as an alternative to LCG especially for the case of enormous histories. It is found that xorshift has desirable features compared with LCG, and xorshift has a larger period, a comparable speed to generate random numbers, a better randomness, and good applicability to parallel calculation. (author)

  11. Linear Accelerator Stereotactic Radiosurgery of Central Nervous System Arteriovenous Malformations: A 15-Year Analysis of Outcome-Related Factors in a Single Tertiary Center.

    Science.gov (United States)

    Thenier-Villa, José Luis; Galárraga-Campoverde, Raúl Alejandro; Martínez Rolán, Rosa María; De La Lama Zaragoza, Adolfo Ramón; Martínez Cueto, Pedro; Muñoz Garzón, Víctor; Salgado Fernández, Manuel; Conde Alonso, Cesáreo

    2017-07-01

    Linear accelerator stereotactic radiosurgery is one of the modalities available for the treatment of central nervous system arteriovenous malformations (AVMs). The aim of this study was to describe our 15-year experience with this technique in a single tertiary center and the analysis of outcome-related factors. From 1998 to 2013, 195 patients were treated with linear accelerator-based radiosurgery; we conducted a retrospective study collecting patient- and AVM-related variables. Treatment outcomes were obliteration, posttreatment hemorrhage, symptomatic radiation-induced changes, and 3-year neurologic status. We also analyzed prognostic factors of each outcome and predictability analysis of 5 scales: Spetzler-Martin grade, Lawton-Young supplementary and Lawton combined scores, radiosurgery-based AVM score, Virginia Radiosurgery AVM Scale, and Heidelberg score. Overall obliteration rate was 81%. Nidus diameter and venous drainage were predictive of obliteration (P linear accelerator-based radiosurgery is a useful, valid, effective, and safe modality for treatment of brain AVMs. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Monte Carlo method implementation on IPSC 860 for the resolution of the Boltzmann equation

    International Nuclear Information System (INIS)

    AloUGES, Francois

    1993-01-01

    This note deals with the implementation on a massively parallel machine (IPSC-860) of a Monte-Carlo method aiming at resolving the Boltzmann equation. The parallelism of the machine incites to consider a multi-domain approach and poses the problem of the automatic generation of local meshes from a non-structured 3-D global mesh [fr

  13. A case of acoustic neurinoma associated with chronic subdural hematoma after gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Sho, Atsuko; Asaeda, Masahiro; Ohtake, Minoru

    2002-01-01

    A 72-year-old female presented with a unique case of acoustic neurinoma with a cystic component followed by the chronic subdural hematoma manifesting as trigeminal neuralgia, facial palsy and trunchal ataxia 7 months after gamma knife radiosurgery. Magnetic resonance imaging demonstrated a loss of central contrast enhancement at the postoperative residual tumor mass and a large cyst associated with a hematoma in the subdural space. A right suboccipital craniectomy was performed. A biopsy of the mass and the membrane was performed following aspiration of the brown-reddish fluid collection. The histological diagnosis was acoustic neurinoma with a hemorrhagic necrosis. The membranous tissue mimicked an outer membrane obtained from chronic subdural hematoma. The postoperative course was satisfactory and preoperative symptom have been alleviated. In this case, the chronic subdural hematoma occurred at posterior fossa during the development of cysts caused by the radiosurgery, because the subdural space had been connected with the subarachnoid space after the first operation. The development of cysts or hematoma should be taken into consideration as possible complications following treatment with gamma knife radiosurgery for acoustic neurinomas. (author)

  14. A case of acoustic neurinoma associated with chronic subdural hematoma after gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Sho, Atsuko; Asaeda, Masahiro; Ohtake, Minoru [Tottori Univ., Yonago (Japan). Inst. of Neurological Sciences] [and others

    2002-09-01

    A 72-year-old female presented with a unique case of acoustic neurinoma with a cystic component followed by the chronic subdural hematoma manifesting as trigeminal neuralgia, facial palsy and trunchal ataxia 7 months after gamma knife radiosurgery. Magnetic resonance imaging demonstrated a loss of central contrast enhancement at the postoperative residual tumor mass and a large cyst associated with a hematoma in the subdural space. A right suboccipital craniectomy was performed. A biopsy of the mass and the membrane was performed following aspiration of the brown-reddish fluid collection. The histological diagnosis was acoustic neurinoma with a hemorrhagic necrosis. The membranous tissue mimicked an outer membrane obtained from chronic subdural hematoma. The postoperative course was satisfactory and preoperative symptom have been alleviated. In this case, the chronic subdural hematoma occurred at posterior fossa during the development of cysts caused by the radiosurgery, because the subdural space had been connected with the subarachnoid space after the first operation. The development of cysts or hematoma should be taken into consideration as possible complications following treatment with gamma knife radiosurgery for acoustic neurinomas. (author)

  15. WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G. [University of California, San Diego (United States)

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  16. WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac

    International Nuclear Information System (INIS)

    Kim, G.

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  17. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  18. Stereotactic gamma radiosurgery of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Oyama, Hirofumi; Yoshida, Kazuo; Maesawa, Satoshi; Kai, Osamu; Nakamura, Mototoshi; Arahata, Masashige [Komaki City Hospital, Aichi (Japan)

    1996-06-01

    One thousand cases with various head and neck diseases have been treated by gamma radiosurgery at Komaki City Hospital since May 1991. Five hundred and sixty-eight out of 1,000 cases were neoplastic lesions which consisted of 173 cases of neurinoma, 108 of metastatic tumors, 103 of meningioma, 69 of gliomas, 27 of pituitary adenoma, 26 of craniopharyngioma, 13 of pineal tumors, 11 of chordoma, 6 of malignant lymphoma, 5 of hemangioblastoma and so on. The most effective result has been shown in metastatic brain tumors. The complete response (disappearance of the lesion) was obtained in more than 50% of the treated lesions, and the control rate of 85% was maintained for more than 12 months. Next effective results were shown in craniopharyngioma, malignant pineal tumors and malignant lymphoma. There was a group which showed moderate response but no tumor disappearance. Those were pituitary adenoma, acoustic neurinoma, meningioma and chordoma. Gliomas showed less response and even progression of tumor at relatively higher rate. It has been found that malignant gliomas showed difficult control of the tumor and progression rate of 70%, while benign gliomas showed the control rate of more than 90%. Besides intracranial lesions, malignant skull base tumors such as chordoma, naso-pharyngeal cancer, adenoid cystic cancer showed better response to gamma radiosurgery and higher control rate for longer period of time with high QOL compaired to conventional irradiation. (author)

  19. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.

    Science.gov (United States)

    Gagnon, Jean-Christophe; Thériault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S(c,p)) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 × 10 cm(2) field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S(c,p) within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore

  20. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada)

    2012-01-15

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone

  1. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    International Nuclear Information System (INIS)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S c,p ) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm 2 field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S c,p within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively

  2. Massively parallel computation of PARASOL code on the Origin 3800 system

    International Nuclear Information System (INIS)

    Hosokawa, Masanari; Takizuka, Tomonori

    2001-10-01

    The divertor particle simulation code named PARASOL simulates open-field plasmas between divertor walls self-consistently by using an electrostatic PIC method and a binary collision Monte Carlo model. The PARASOL parallelized with MPI-1.1 for scalar parallel computer worked on Intel Paragon XP/S system. A system SGI Origin 3800 was newly installed (May, 2001). The parallel programming was improved at this switchover. As a result of the high-performance new hardware and this improvement, the PARASOL is speeded up by about 60 times with the same number of processors. (author)

  3. Parallel computation

    International Nuclear Information System (INIS)

    Jejcic, A.; Maillard, J.; Maurel, G.; Silva, J.; Wolff-Bacha, F.

    1997-01-01

    The work in the field of parallel processing has developed as research activities using several numerical Monte Carlo simulations related to basic or applied current problems of nuclear and particle physics. For the applications utilizing the GEANT code development or improvement works were done on parts simulating low energy physical phenomena like radiation, transport and interaction. The problem of actinide burning by means of accelerators was approached using a simulation with the GEANT code. A program of neutron tracking in the range of low energies up to the thermal region has been developed. It is coupled to the GEANT code and permits in a single pass the simulation of a hybrid reactor core receiving a proton burst. Other works in this field refers to simulations for nuclear medicine applications like, for instance, development of biological probes, evaluation and characterization of the gamma cameras (collimators, crystal thickness) as well as the method for dosimetric calculations. Particularly, these calculations are suited for a geometrical parallelization approach especially adapted to parallel machines of the TN310 type. Other works mentioned in the same field refer to simulation of the electron channelling in crystals and simulation of the beam-beam interaction effect in colliders. The GEANT code was also used to simulate the operation of germanium detectors designed for natural and artificial radioactivity monitoring of environment

  4. The surgical treatment strategy and results of parasellar meningiomas in the era of radiosurgery

    International Nuclear Information System (INIS)

    Iwai, Yoshiyasu; Yamanaka, Kazuhiro; Morikawa, Toshie; Ishiguro, Tomoya; Honda, Yuji; Matsuzaka, Yasuhiro; Komiyama, Masaki; Yasui, Toshihiro

    2003-01-01

    We evaluated the surgical treatment results of parasellar meningiomas in the era of radiosurgery. We treated 24 patients of parasellar meningiomas surgically. The median age was 60 yrs (ranging from 29 to 82 yrs). The most common tumor location was the sphenoid ridge in 12 patients and the tuberculum sellae in 7 patients. The pterional approach using fronto-temporal craniotomy was performed for all patients. The residual or recurrent tumors were treated by gamma knife radiosurgery (GKS). We are able to follow up these cases for a median of 3.8 yrs (ranging from 1 to 8 yrs) after the operations. The radicality of tumor resection was Simpson grade II in 13 patients (54%), grade III in 3 patients (13%) and grade IV in 7 patients (33%). Clinical improvement was achieved in 81% of the patients. Of the patients who had visual disturbance preoperatively, 8 patients (73%) showed improvement, but 3 patients suffered deterioration postoperatively. None of the patients died. One patient suffered transient memory disturbance and one patient suffered mild facial numbness postoperatively. Boost radiosurgery for the residual tumors was performed for six patients and tumor growth control was able to be achieved in all patients, with a median of 3.1 years follow-up period (ranging from 0.5 to 6 yrs). Five patients with tumor regrowth or recurrence were treated by GKS. We recommend fronto-temporal craniotomy with nonradical resection for parasellar meningiomas and radiosurgery for residual and recurrent tumors. This strategy will achieve good functional outcome with long-term tumor growth control. (author)

  5. Morphological and functional MRI, MRS, perfusion and diffusion changes after radiosurgery of brain metastasis

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Kim, Sung Tae; Byun, Hong Sik; Jeon, Pyoung; Kim, Keonha; Kim, Hyungjin; Lee, Jung II

    2009-01-01

    Radiosurgery is a noninvasive procedure where spatially accurate and highly conformal doses of radiation are targeted at brain lesions with an ablative intent. Recently, radiosurgery has been established as an effective technique for local treatment of brain metastasis. After radiosurgery, magnetic resonance (MR) imaging plays an important role in the assessment of the therapeutic response and of any complications. The therapeutic approach depends on the imaging findings obtained after radiosurgery, which have a role in the decision making to perform additional invasive modalities (repeat resection, biopsy) to obtain a definite diagnosis and to improve the survival of patients. Conventional MR imaging findings are mainly based on morphological alterations of tumors. However, there are variable imaging findings of radiation-induced changes including radiation necrosis in the brain. Radiologists are sometimes confused by radiation-induced injuries, including radiation necrosis, that are seen on conventional MR imaging. The pattern of abnormal enhancement on follow-up conventional MR imaging closely mimics that of a recurrent brain metastasis. So, classifying newly developed abnormal enhancing lesions in follow-up of treated brain metastasis with correct diagnosis is one of the key goals in neuro-oncologic imaging. To overcome limitations of the use of morphology-based conventional MR imaging, several physiological-based functional MR imaging methods have been used, namely diffusion-weighted imaging, perfusion MR imaging, and proton MR spectroscopy, for the detection of hemodynamic, metabolic, and cellular alterations. These imaging modalities provide additional information to allow clinicians to make proper decisions regarding patient treatment.

  6. Feasibility Study of Core Design with a Monte Carlo Code for APR1400 Initial core

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinsun; Chang, Do Ik; Seong, Kibong [KEPCO NF, Daejeon (Korea, Republic of)

    2014-10-15

    The Monte Carlo calculation becomes more popular and useful nowadays due to the rapid progress in computing power and parallel calculation techniques. There have been many attempts to analyze a commercial core by Monte Carlo transport code using the enhanced computer capability, recently. In this paper, Monte Carlo calculation of APR1400 initial core has been performed and the results are compared with the calculation results of conventional deterministic code to find out the feasibility of core design using Monte Carlo code. SERPENT, a 3D continuous-energy Monte Carlo reactor physics burnup calculation code is used for this purpose and the KARMA-ASTRA code system, which is used for a deterministic code of comparison. The preliminary investigation for the feasibility of commercial core design with Monte Carlo code was performed in this study. Simplified core geometry modeling was performed for the reactor core surroundings and reactor coolant model is based on two region model. The reactivity difference at HZP ARO condition between Monte Carlo code and the deterministic code is consistent with each other and the reactivity difference during the depletion could be reduced by adopting the realistic moderator temperature. The reactivity difference calculated at HFP, BOC, ARO equilibrium condition was 180 ±9 pcm, with axial moderator temperature of a deterministic code. The computing time will be a significant burden at this time for the application of Monte Carlo code to the commercial core design even with the application of parallel computing because numerous core simulations are required for actual loading pattern search. One of the remedy will be a combination of Monte Carlo code and the deterministic code to generate the physics data. The comparison of physics parameters with sophisticated moderator temperature modeling and depletion will be performed for a further study.

  7. Parallelism in computations in quantum and statistical mechanics

    International Nuclear Information System (INIS)

    Clementi, E.; Corongiu, G.; Detrich, J.H.

    1985-01-01

    Often very fundamental biochemical and biophysical problems defy simulations because of limitations in today's computers. We present and discuss a distributed system composed of two IBM 4341 s and/or an IBM 4381 as front-end processors and ten FPS-164 attached array processors. This parallel system - called LCAP - has presently a peak performance of about 110 Mflops; extensions to higher performance are discussed. Presently, the system applications use a modified version of VM/SP as the operating system: description of the modifications is given. Three applications programs have been migrated from sequential to parallel: a molecular quantum mechanical, a Metropolis-Monte Carlo and a molecular dynamics program. Descriptions of the parallel codes are briefly outlined. Use of these parallel codes has already opened up new capabilities for our research. The very positive performance comparisons with today's supercomputers allow us to conclude that parallel computers and programming, of the type we have considered, represent a pragmatic answer to many computationally intensive problems. (orig.)

  8. Practical Application of Monte Carlo Code in RTP

    International Nuclear Information System (INIS)

    Mohamad Hairie Rabir; Julia Abdul Karim; Muhammad Rawi Mohamed Zin; Na'im Syauqi Hamzah; Mark Dennis Anak Usang; Abi Muttaqin Jalal Bayar; Muhammad Khairul Ariff Mustafa

    2015-01-01

    Monte Carlo neutron transport codes are widely used in various reactor physics applications in RTP and other related nuclear and radiation research in Nuklear Malaysia. The main advantage of the method is the capability to model geometry and interaction physics without major approximations. The disadvantage is that the modelling of complicated systems is very computing-intensive, which restricts the applications to some extent. The importance of Monte Carlo calculation is likely to increase in the future, along with the development in computer capacities and parallel calculation. This paper presents several calculation activities, its achievements and challenges in using MCNP code for neutronics analysis, nuclide inventory and source term calculation, shielding and dose evaluation. (author)

  9. A multi-microcomputer system for Monte Carlo calculations

    International Nuclear Information System (INIS)

    Hertzberger, L.O.; Berg, B.; Krasemann, H.

    1981-01-01

    We propose a microcomputer system which allows parallel processing for Monte Carlo calculations in lattice gauge theories, simulations of high energy physics experiments and presumably many other fields of current interest. The master-n-slave multiprocessor system is based on the Motorola MC 68000 microprocessor. One attraction if this processor is that it allows up to 16 M Byte random access memory. (orig.)

  10. Radiosurgery supported in the lineal accelerator for the acoustic neuroma treatment

    International Nuclear Information System (INIS)

    Santos Ortega, M.; Gutierrez Diaz, J.; Rodriguez Villaba, S.; Garcia Berrocal, I.; Samblas Garcia, J.; Bustos Perez de Salcedo, J.C.; Ortiz de Urbina, D.; Donckaster Clavero, G.; Delgado Rodriguez, J.M.; Sansivirini Valle, F.

    1996-01-01

    Radiosurgery becomes in a great interest technique in acoustic neuroma treatments. We present preliminary results over 74 neurinomas patients in our Unit. From August 1991 to August 1994, 74 consecutive patients with acoustic neuromas, median age 50 yrs. has been treated in our Unit. A SRS 200 radiosurgery system was employed using a 6 MV photon beam Linear Accelerator as radiation source. In every case treatment dose was lesser than 18 gy (14-16 Gy). Before treatment all patients were evaluated with MRI and neurological examination, acoustic test included. This screening was repeated each six months during the follow up. Tumoral control was defined both, as no changes or diminishing in tumoral size, observed in sequential MRI studies with gadolinium and comparable techniques. The median fallow up is 18 months. Tumor control is 88,5%. In 30 patients control means dismissing in tumoral size. In 10 patients tumoral progression was evident, in a half of their a neurofibromatosis type II was previously diagnosed. The neurological function during the follow up shown improve or estabilitation in symptoms, for 85% VII pair patients, 83% in VII pair patients, 86% in V pair patients and 83% in cerebellar disfunction patients. Although preliminaries, this dates showing the efficacy of radiosurgery in tumoral control of patients with neurinomas with doses laser than 18 Gy. This dose are safe with toxicities around 15%, mainly in transitory presentations. (Auhtor) 67 refs

  11. Present Status and Extensions of the Monte Carlo Performance Benchmark

    Science.gov (United States)

    Hoogenboom, J. Eduard; Petrovic, Bojan; Martin, William R.

    2014-06-01

    The NEA Monte Carlo Performance benchmark started in 2011 aiming to monitor over the years the abilities to perform a full-size Monte Carlo reactor core calculation with a detailed power production for each fuel pin with axial distribution. This paper gives an overview of the contributed results thus far. It shows that reaching a statistical accuracy of 1 % for most of the small fuel zones requires about 100 billion neutron histories. The efficiency of parallel execution of Monte Carlo codes on a large number of processor cores shows clear limitations for computer clusters with common type computer nodes. However, using true supercomputers the speedup of parallel calculations is increasing up to large numbers of processor cores. More experience is needed from calculations on true supercomputers using large numbers of processors in order to predict if the requested calculations can be done in a short time. As the specifications of the reactor geometry for this benchmark test are well suited for further investigations of full-core Monte Carlo calculations and a need is felt for testing other issues than its computational performance, proposals are presented for extending the benchmark to a suite of benchmark problems for evaluating fission source convergence for a system with a high dominance ratio, for coupling with thermal-hydraulics calculations to evaluate the use of different temperatures and coolant densities and to study the correctness and effectiveness of burnup calculations. Moreover, other contemporary proposals for a full-core calculation with realistic geometry and material composition will be discussed.

  12. Present status and extensions of the Monte Carlo performance benchmark

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.; Petrovic, B.; Martin, W.R.

    2013-01-01

    The NEA Monte Carlo Performance benchmark started in 2011 aiming to monitor over the years the abilities to perform a full-size Monte Carlo reactor core calculation with a detailed power production for each fuel pin with axial distribution. This paper gives an overview of the contributed results thus far. It shows that reaching a statistical accuracy of 1 % for most of the small fuel zones requires about 100 billion neutron histories. The efficiency of parallel execution of Monte Carlo codes on a large number of processor cores shows clear limitations for computer clusters with common type computer nodes. However, using true supercomputers the speedup of parallel calculations is increasing up to large numbers of processor cores. More experience is needed from calculations on true supercomputers using large numbers of processors in order to predict if the requested calculations can be done in a short time. As the specifications of the reactor geometry for this benchmark test are well suited for further investigations of full-core Monte Carlo calculations and a need is felt for testing other issues than its computational performance, proposals are presented for extending the benchmark to a suite of benchmark problems for evaluating fission source convergence for a system with a high dominance ratio, for coupling with thermal-hydraulics calculations to evaluate the use of different temperatures and coolant densities and to study the correctness and effectiveness of burnup calculations. Moreover, other contemporary proposals for a full-core calculation with realistic geometry and material composition will be discussed. (authors)

  13. Neuropsychological results after gamma knife radiosurgery for mesial temporal lobe epilepsy.

    Science.gov (United States)

    Vojtěch, Zdeněk; Krámská, Lenka; Malíková, Hana; Stará, Michaela; Liščák, Roman

    2015-01-01

    The aim of this study is to summarize our experience with neuropsychological changes after radiosurgical treatment for mesial temporal lobe epilepsy and subsequent surgery due to insufficient seizure control. Between November 1995 and May 1999, 14 patients underwent radiosurgical entorhinoamygdalohippocampectomy with a marginal dose of 18, 20 or 25 Gy to the 50% isodose. 9 of these patients subsequently underwent surgery. We compared Memory Quotients and Intelligence Quotients before and after the interventions. We found a slight, but nonsignificant decline in intelligence and memory quotients one year after GKRS. Two years after radiosurgery there were no significant changes in any of the quotients. After surgery, we found significant increase in Global and Visual MQ, (pmemory and intelligence performance after surgery. Epilepsy surgery after unsuccessful radiosurgery could lead to improvements in cognitive functions in patients with mesial temporal lobe epilepsy.

  14. An integrated logistic formula for prediction of complications from radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, J.C.

    1989-01-01

    An integrated logistic model for predicting the probability of complications when small volumes of tissue receive an inhomogeneous radiation dose is described. This model can be used with either an exponential or linear quadratic correction for dose per fraction and time. Both the exponential and linear quadratic versions of this integrated logistic formula provide reasonable estimates of the tolerance of brain to radiosurgical dose distributions where there are small volumes of brain receiving high radiation doses and larger volumes receiving lower doses. This makes it possible to predict the probability of complications from stereotactic radiosurgery, as well as combinations of fractionated large volume irradiation with a radiosurgical boost. Complication probabilities predicted for single fraction radiosurgery with the Leksell Gamma Unit using 4, 8, 14, and 18 mm diameter collimators as well as for whole brain irradiation combined with a radiosurgical boost are presented. The exponential and linear quadratic versions of the integrated logistic formula provide useful methods of calculating the probability of complications from radiosurgical treatment

  15. Parallel simulation of radio-frequency plasma discharges

    International Nuclear Information System (INIS)

    Fivaz, M.; Howling, A.; Ruegsegger, L.; Schwarzenbach, W.; Baeumle, B.

    1994-01-01

    The 1D Particle-In-Cell and Monte Carlo collision code XPDP1 is used to model radio-frequency argon plasma discharges. The code runs faster on a single-user parallel system called MUSIC than on a CRAY-YMP. The low cost of the MUSIC system allows a 24-hours-per-day use and the simulation results are available one to two orders of magnitude quicker than with a super computer shared with other users. The parallelization strategy and its implementation are discussed. Very good agreement is found between simulation results and measurements done in an experimental argon discharge. (author) 2 figs., 3 refs

  16. Hybrid surgery-radiosurgery therapy for metastatic epidural spinal cord compression: A prospective evaluation using patient-reported outcomes.

    Science.gov (United States)

    Barzilai, Ori; Amato, Mary-Kate; McLaughlin, Lily; Reiner, Anne S; Ogilvie, Shahiba Q; Lis, Eric; Yamada, Yoshiya; Bilsky, Mark H; Laufer, Ilya

    2018-05-01

    Patient-reported outcomes (PRO) represent an important measure of cancer therapy effect. For patients with metastatic epidural spinal cord compression (MESCC), hybrid therapy using separation surgery and stereotactic radiosurgery preserves neurologic function and provides tumor control. There is currently a paucity of data reporting PRO after such combined modality therapy for MESCC. Delineation of hybrid surgery-radiosurgery therapy effect on PRO validates the hybrid approach as an effective therapy resulting in meaningful symptom relief. Brief Pain Inventory (BPI) and MD Anderson Symptom Inventory-Spine Tumor (MDASI-SP), PROs validated in the cancer population, were prospectively collected. Patients with MESCC who underwent separation surgery followed by stereotactic radiosurgery were included. Separation surgery included a posterolateral approach without extensive cytoreductive tumor excision. A median postoperative radiosurgery dose of 2700 cGy was delivered. The change in PRO 3 months after the hybrid therapy represented the primary study outcome. Preoperative and postoperative evaluations were analyzed using the Wilcoxon signed-rank test for matched pairs. One hundred eleven patients were included. Hybrid therapy resulted in a significant reduction in the BPI items "worst" and "right now" pain ( P < .0001), and in all BPI constructs (severity, interference with daily activities, and pain experience, P < .001). The MDASI-SP demonstrated reduction in spine-specific pain severity and interference with general activity ( P < .001), along with decreased symptom interference ( P < .001). Validated PRO instruments showed that in patients with MESCC, hybrid therapy with separation surgery and radiosurgery results in a significant decrease in pain severity and symptom interference. These prospective data confirm the benefit of hybrid therapy for treatment of MESCC and should facilitate referral of patients with MESCC for surgical evaluation.

  17. Gamma knife radiosurgery for secreting pituitary tumors

    International Nuclear Information System (INIS)

    Noren, G.; Jackson, I.M.D.; Chougule, P.; Zheng, Z.; Epstein, M.H.

    1998-01-01

    Transsphenoidal surgery usually represents first line treatment for pituitary adenomas with the aim of removing the tumor, decompressing the optic apparatus and, in secreting tumors, eliminating the hypersecretion. Gamma Knife radiosurgery is indicated for tumor remnants or recurrences in or above the sella including those invading the cavernous sinus and also as initial treatment in patients who are unable to tolerate an open surgical procedure and where medication has failed. In this study, the target definition was retrospectively studied and when necessary corrected in 10 acromegalic patients, 8 with Cushing's disease, and 12 with prolactinomas undergoing Gamma Knife radiosurgery. The dose plan was analyzed and the volume of the target covered by a minimum of 15, 20, 25, 30 and 35 Gy was estimated. A dose/volume profile for each treatment was created and correlated to the endocrinological and clinical outcome. Cure, according to strict endocrinological criteria, was seen in 6 of the acromegalic patients, in 2 of the patients with ACTH hypersecretion, and in 2 of the patients with prolactinomas. Analysis of these profiles, also for the patients with partial effect, show that a minimum radiation dose of 20 Gy may be adequate to eliminate the hypersecretion in acromegalic patients whereas a dose of at least 25 Gy may be required in patients with Cushing's disease and prolactinoma. (author)

  18. Feasibility studies for a high energy physics MC program on massive parallel platforms

    International Nuclear Information System (INIS)

    Bertolotto, L.M.; Peach, K.J.; Apostolakis, J.; Bruschini, C.E.; Calafiura, P.; Gagliardi, F.; Metcalf, M.; Norton, A.; Panzer-Steindel, B.

    1994-01-01

    The parallelization of a Monte Carlo program for the NA48 experiment is presented. As a first step, a task farming structure was realized. Based on this, a further step, making use of a distributed database for showers in the electro-magnetic calorimeter, was implemented. Further possibilities for using parallel processing for a quasi-real time calibration of the calorimeter are described

  19. A NEW MONTE CARLO METHOD FOR TIME-DEPENDENT NEUTRINO RADIATION TRANSPORT

    International Nuclear Information System (INIS)

    Abdikamalov, Ernazar; Ott, Christian D.; O'Connor, Evan; Burrows, Adam; Dolence, Joshua C.; Löffler, Frank; Schnetter, Erik

    2012-01-01

    Monte Carlo approaches to radiation transport have several attractive properties such as simplicity of implementation, high accuracy, and good parallel scaling. Moreover, Monte Carlo methods can handle complicated geometries and are relatively easy to extend to multiple spatial dimensions, which makes them potentially interesting in modeling complex multi-dimensional astrophysical phenomena such as core-collapse supernovae. The aim of this paper is to explore Monte Carlo methods for modeling neutrino transport in core-collapse supernovae. We generalize the Implicit Monte Carlo photon transport scheme of Fleck and Cummings and gray discrete-diffusion scheme of Densmore et al. to energy-, time-, and velocity-dependent neutrino transport. Using our 1D spherically-symmetric implementation, we show that, similar to the photon transport case, the implicit scheme enables significantly larger timesteps compared with explicit time discretization, without sacrificing accuracy, while the discrete-diffusion method leads to significant speed-ups at high optical depth. Our results suggest that a combination of spectral, velocity-dependent, Implicit Monte Carlo and discrete-diffusion Monte Carlo methods represents a robust approach for use in neutrino transport calculations in core-collapse supernovae. Our velocity-dependent scheme can easily be adapted to photon transport.

  20. A NEW MONTE CARLO METHOD FOR TIME-DEPENDENT NEUTRINO RADIATION TRANSPORT

    Energy Technology Data Exchange (ETDEWEB)

    Abdikamalov, Ernazar; Ott, Christian D.; O' Connor, Evan [TAPIR, California Institute of Technology, MC 350-17, 1200 E California Blvd., Pasadena, CA 91125 (United States); Burrows, Adam; Dolence, Joshua C. [Department of Astrophysical Sciences, Princeton University, Peyton Hall, Ivy Lane, Princeton, NJ 08544 (United States); Loeffler, Frank; Schnetter, Erik, E-mail: abdik@tapir.caltech.edu [Center for Computation and Technology, Louisiana State University, 216 Johnston Hall, Baton Rouge, LA 70803 (United States)

    2012-08-20

    Monte Carlo approaches to radiation transport have several attractive properties such as simplicity of implementation, high accuracy, and good parallel scaling. Moreover, Monte Carlo methods can handle complicated geometries and are relatively easy to extend to multiple spatial dimensions, which makes them potentially interesting in modeling complex multi-dimensional astrophysical phenomena such as core-collapse supernovae. The aim of this paper is to explore Monte Carlo methods for modeling neutrino transport in core-collapse supernovae. We generalize the Implicit Monte Carlo photon transport scheme of Fleck and Cummings and gray discrete-diffusion scheme of Densmore et al. to energy-, time-, and velocity-dependent neutrino transport. Using our 1D spherically-symmetric implementation, we show that, similar to the photon transport case, the implicit scheme enables significantly larger timesteps compared with explicit time discretization, without sacrificing accuracy, while the discrete-diffusion method leads to significant speed-ups at high optical depth. Our results suggest that a combination of spectral, velocity-dependent, Implicit Monte Carlo and discrete-diffusion Monte Carlo methods represents a robust approach for use in neutrino transport calculations in core-collapse supernovae. Our velocity-dependent scheme can easily be adapted to photon transport.

  1. Development and benchmark verification of a parallelized Monte Carlo burnup calculation program MCBMPI

    International Nuclear Information System (INIS)

    Yang Wankui; Liu Yaoguang; Ma Jimin; Yang Xin; Wang Guanbo

    2014-01-01

    MCBMPI, a parallelized burnup calculation program, was developed. The program is modularized. Neutron transport calculation module employs the parallelized MCNP5 program MCNP5MPI, and burnup calculation module employs ORIGEN2, with the MPI parallel zone decomposition strategy. The program system only consists of MCNP5MPI and an interface subroutine. The interface subroutine achieves three main functions, i.e. zone decomposition, nuclide transferring and decaying, data exchanging with MCNP5MPI. Also, the program was verified with the Pressurized Water Reactor (PWR) cell burnup benchmark, the results showed that it's capable to apply the program to burnup calculation of multiple zones, and the computation efficiency could be significantly improved with the development of computer hardware. (authors)

  2. Salvage gamma knife radiosurgery in the management of dysembryoplastic neuroepithelial tumors

    DEFF Research Database (Denmark)

    Sinclair, Georges; Martin, Heather; Shamikh, Alia

    2017-01-01

    BACKGROUND: Dysembryoplastic neuroepithelial tumors (DNT/DNET) are rare epileptogenic tumors. Microsurgery remains the best treatment option, although case reports exist on the use of gamma knife radiosurgery (GKRS) in selected cases. We investigated the long-term outcome of GKRS-treated DNTs...

  3. Imaging of rare radiation injuries after radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Yamanaka, Kazuhiro; Yoshimura, Masaki; Iwai, Yoshiyasu

    2011-01-01

    Gamma knife radiosurgery (GKS) is generally an effective and safe treatment for brain metastases. We report 3 rare complicated cases after GKS due to radiation injury including image findings. Case 1: A 58-year-old man received whole brain radiation therapy for right occipital brain metastasis from lung cancer. However, local recurrence was noted and GKS was carried out 5 months later (size 28 mm, marginal dose 23 Gy (50% isodose)). Four years later, a cyst appeared and the patient developed apraxia and visual disturbance. Surgery was performed and the histopathology showed necrosis. Case 2: A 51-year-old woman received GKS for 4 brain metastases from breast cancer. The right occipital lobe lesion was treated with marginal dose of 18 Gy (size 24 mm, 50% isodose). Thirty-one months later, she developed left homonymous hemianopsia and MR imaging and CT scan showed intracerebral hemorrhage with cyst formation. An operation was performed and the histology revealed necrosis. Case 3: A 37-year-old man received GKS for left temporal brain metastasis from lung cancer (size 14 mm, marginal dose 23 Gy (50% isodose)). Twelve months later, the lesion increased in size again, so we carried out a second GKS on the same lesion (size 15 mm, marginal dose 23 Gy (50% isodose)). Thirty-five months later, massive peritumoral edema appeared and the patient developed left oculomotor palsy. An emergency operation was performed and the histopathological diagnosis was cavernous malformation that was thought to be induced by radiosurgery. Although the incidence is low, rare complications associated with radiation therapy can also occur by radiosurgery. (author)

  4. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    International Nuclear Information System (INIS)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade; Laufer, Ilya

    2016-01-01

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  5. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Taunk, Neil Kanth; Yamada, Yoshiya [Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Laufer, Ilya, E-mail: fymoraes@gmail.com [Memorial Sloan Kettering Cancer Center, Department of Neurosurgery, New York, NY (United States)

    2016-02-15

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  6. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    Energy Technology Data Exchange (ETDEWEB)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M. [Department of Radiation Oncology, Erasmus MC-Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2011-03-15

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  7. Shortening treatment time in robotic radiosurgery using a novel node reduction technique

    International Nuclear Information System (INIS)

    Water, Steven van de; Hoogeman, Mischa S.; Breedveld, Sebastiaan; Heijmen, Ben J. M.

    2011-01-01

    Purpose: The fraction duration of robotic radiosurgery treatments can be reduced by generating more time-efficient treatment plans with a reduced number of node positions, beams, and monitor units (MUs). Node positions are preprogramed locations where the robot can position the focal spot of the x-ray beam. As the time needed for the robot to travel between node positions takes up a large part of the treatment time, the aim of this study was to develop and evaluate a node reduction technique in order to reduce the treatment time per fraction for robotic radiosurgery. Methods: Node reduction was integrated into the inverse planning algorithm, developed in-house for the robotic radiosurgery modality. It involved repeated inverse optimization, each iteration excluding low-contribution node positions from the planning and resampling new candidate beams from the remaining node positions. Node reduction was performed until the exclusion of a single node position caused a constraint violation, after which the shortest treatment plan was selected retrospectively. Treatment plans were generated with and without node reduction for two lung cases of different complexity, one oropharyngeal case and one prostate case. Plan quality was assessed using the number of node positions, beams and MUs, and the estimated treatment time per fraction. All treatment plans had to fulfill all clinical dose constraints. Extra constraints were added to maintain the low-dose conformality and restrict skin doses during node reduction. Results: Node reduction resulted in 12 residual node positions, on average (reduction by 77%), at the cost of an increase in the number of beams and total MUs of 28% and 9%, respectively. Overall fraction durations (excluding patient setup) were shortened by 25% (range of 18%-40%), on average. Dose distributions changed only little and dose in low-dose regions was effectively restricted by the additional constraints. Conclusions: The fraction duration of robotic

  8. SU-E-T-420: Failure Effects Mode Analysis for Trigeminal Neuralgia Frameless Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Howe, J [Associates In Medical Physics, Louisville, KY (United States)

    2015-06-15

    Purpose: Functional radiosurgery has been used successfully in the treatment of trigeminal neuralgia but presents significant challenges to ensuring the high prescription dose is delivered accurately. A review of existing practice should help direct the focus of quality improvement for this treatment regime. Method: Failure modes and effects analysis was used to identify the processes in preparing radiosurgery treatment for TN. The map was developed by a multidisciplinary team including: neurosurgeon, radiation oncology, physicist and therapist. Potential failure modes were identified for each step in the process map as well as potential causes and end effect. A risk priority number was assigned to each cause. Results: The process map identified 66 individual steps (see attached supporting document). Corrective actions were developed for areas of high risk priority number. Wrong site treatment is at higher risk for trigeminal neuralgia treatment due to the lack of site specific pathologic imaging on MR and CT – additional site specific checks were implemented to minimize the risk of wrong site treatment. Failed collision checks resulted from an insufficient collision model in the treatment planning system and a plan template was developed to address this problem. Conclusion: Failure modes and effects analysis is an effective tool for developing quality improvement in high risk radiotherapy procedures such as functional radiosurgery.

  9. SU-E-T-420: Failure Effects Mode Analysis for Trigeminal Neuralgia Frameless Radiosurgery

    International Nuclear Information System (INIS)

    Howe, J

    2015-01-01

    Purpose: Functional radiosurgery has been used successfully in the treatment of trigeminal neuralgia but presents significant challenges to ensuring the high prescription dose is delivered accurately. A review of existing practice should help direct the focus of quality improvement for this treatment regime. Method: Failure modes and effects analysis was used to identify the processes in preparing radiosurgery treatment for TN. The map was developed by a multidisciplinary team including: neurosurgeon, radiation oncology, physicist and therapist. Potential failure modes were identified for each step in the process map as well as potential causes and end effect. A risk priority number was assigned to each cause. Results: The process map identified 66 individual steps (see attached supporting document). Corrective actions were developed for areas of high risk priority number. Wrong site treatment is at higher risk for trigeminal neuralgia treatment due to the lack of site specific pathologic imaging on MR and CT – additional site specific checks were implemented to minimize the risk of wrong site treatment. Failed collision checks resulted from an insufficient collision model in the treatment planning system and a plan template was developed to address this problem. Conclusion: Failure modes and effects analysis is an effective tool for developing quality improvement in high risk radiotherapy procedures such as functional radiosurgery

  10. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  11. Spatial data analytics on heterogeneous multi- and many-core parallel architectures using python

    Science.gov (United States)

    Laura, Jason R.; Rey, Sergio J.

    2017-01-01

    Parallel vector spatial analysis concerns the application of parallel computational methods to facilitate vector-based spatial analysis. The history of parallel computation in spatial analysis is reviewed, and this work is placed into the broader context of high-performance computing (HPC) and parallelization research. The rise of cyber infrastructure and its manifestation in spatial analysis as CyberGIScience is seen as a main driver of renewed interest in parallel computation in the spatial sciences. Key problems in spatial analysis that have been the focus of parallel computing are covered. Chief among these are spatial optimization problems, computational geometric problems including polygonization and spatial contiguity detection, the use of Monte Carlo Markov chain simulation in spatial statistics, and parallel implementations of spatial econometric methods. Future directions for research on parallelization in computational spatial analysis are outlined.

  12. Calculations of pair production by Monte Carlo methods

    International Nuclear Information System (INIS)

    Bottcher, C.; Strayer, M.R.

    1991-01-01

    We describe some of the technical design issues associated with the production of particle-antiparticle pairs in very large accelerators. To answer these questions requires extensive calculation of Feynman diagrams, in effect multi-dimensional integrals, which we evaluate by Monte Carlo methods on a variety of supercomputers. We present some portable algorithms for generating random numbers on vector and parallel architecture machines. 12 refs., 14 figs

  13. Grading of vestibular schwannomas and corresponding tumor volumes: ramifications for radiosurgery.

    Science.gov (United States)

    Mindermann, T; Schlegel, I

    2013-01-01

    Patients with vestibular schwannomas (VS) are either assigned to watchful waiting, microsurgical resection, or radiosurgery. Decision making on how to proceed is based on parameters such as age, tumor growth, loss of hearing, and the tumor's Koos grading. In order to correlate Koos grading with tumor volume, patient records of 235 patients with VS who underwent Gamma Knife radiosurgery (GKRS) were retrospectively reviewed. From 1994 to 2009, 235 consecutive patients underwent GKRS for sporadic VS at the Zurich Gamma Knife Center. Median follow up was 62.8 ± 33.0 months. Of the 235 tumors, 32 (13.6 %) were graded Koos I with a volume of 0.25 ± 0.3 cc; 71 (30.2 %) were graded Koos II with a volume of 0.57 ± 0.54 cc; 70 (29.8 %) were graded Koos III with a volume of 1.82 ± 1.88 cc; and 62 (26.4 %) were graded Koos IV with a volume of 4.17 ± 2.75 cc. Tumor progression was defined as a volume increase > 20 % at 2 years or later following GKRS. Overall tumor progression occurred in 21/235 (8.9 %) patients at 3.4 ± 0.9 years. Tumor progression did not differ statistically significantly in the various Koos grades: 1/32 (3.1 %) patients with VS Koos Grade I, 7/71 (9.8 %) patients with VS Koos Grade II, 6/70 (8.6 %) patients with VS Koos Grade III, and 7/62 (11.3 %) patients with VS Koos Grade IV. To our knowledge, this is the first work correlating the various Koos grades of VS to their respective tumor volumes. In our patients, tumor volumes of VS Koos Grade IV were limited because all of our patients were eligible for radiosurgery. In our series, the outcome following GKRS for patients with VS Koos Grade IV tumors did not differ from patients with VS Koos Grades I-III. We therefore suggest to limit Koos Grade IV VS to tumor volumes 6 cc that may not be eligible for radiosurgery.

  14. Comparison of CO(2) laser and 4.0 MHz radiosurgery for making incisions in the skin and muscles of green iguanas (Iguana iguana).

    Science.gov (United States)

    Hernández-Divers, S J; Stahl, S J; Rakich, P M; Blas-Machado, U

    2009-01-03

    Four green iguanas scheduled for euthanasia were used to compare the extent of collateral tissue damage associated with CO(2) laser and 4.0 MHz radiosurgery. The iguanas were anaesthetised and a series of three skin and three muscle incisions was made by 4.0 MHz radiosurgery (0.18 mm wire electrode, 25 W, cut mode) and CO(2) laser (0.3 mm ceramic tip, 15 W focused beam super-pulse mode), and three incisions were made with a scalpel blade as controls. Following euthanasia, a total of 60 skin and 36 muscle sections were evaluated histologically. Radiosurgery and the laser both produced bloodless incisions, but radiosurgery caused significantly less collateral tissue damage in the skin (307 [97] v 386 [108] microm) and the muscle (18 [7] v 91 [15] microm).

  15. Monte Carlo evaluation of path integral for the nuclear shell model

    International Nuclear Information System (INIS)

    Lang, G.H.

    1993-01-01

    The authors present a path-integral formulation of the nuclear shell model using auxillary fields; the path-integral is evaluated by Monte Carlo methods. The method scales favorably with valence-nucleon number and shell-model basis: full-basis calculations are demonstrated up to the rare-earth region, which cannot be treated by other methods. Observables are calculated for the ground state and in a thermal ensemble. Dynamical correlations are obtained, from which strength functions are extracted through the Maximum Entropy method. Examples in the s-d shell, where exact diagonalization can be carried out, compared well with exact results. The open-quotes sign problemclose quotes generic to quantum Monte Carlo calculations is found to be absent in the attractive pairing-plus-multipole interactions. The formulation is general for interacting fermion systems and is well suited for parallel computation. The authors have implemented it on the Intel Touchstone Delta System, achieving better than 99% parallelization

  16. Stereotactic radiosurgery may contribute to overall survival for patients with recurrent head and neck carcinoma

    International Nuclear Information System (INIS)

    Kawaguchi, Koji; Sato, Kengo; Horie, Akihisa; Iketani, Susumu; Yamada, Hiroyuki; Nakatani, Yasunori; Sato, Junichi; Hamada, Yoshiki

    2010-01-01

    The aim of this study is to examine the effect of stereotactic radiosurgery (SRS) in the treatment of advanced, recurrent lesions for head and neck carcinoma both with and without lymph node involvement. Between April 2006 and July 2007, 22 patients (mean age 67 years) with advanced, recurrent head and neck carcinoma were treated with stereotactic radiosurgery. All of the patients except one had biopsy confirmed disease prior to stereotactic radiosurgery. Patients included 3 rT2, 8 rT3, and 9 rT4; 8 of the patients had lymph node metastases. Marginal SRS doses were 20-42 Gy delivered in two to five fractions. Starting one month after SRS, all patients received S-1 oral chemotherapy for one year. At an overall median follow-up of 24 months (range, 4-39 months), for the 14 locally recurrent patients without lymph node metastases, 9 patients (64.3%) had a complete response (CR), 1 patient (7.1%) had a partial response (PR), 1 patient (7.1%) had stable disease (SD), and 3 patients (21.4%) had progressive disease (PD). For the 8 patients with lymph node metastases, 1 patient with a single retropharyngeal (12.5%) had CR; the remaining 7 patients (87.5%) all progressed. Nine patients have died from their cancer. The overall actuarial 2-year survival for the patients with and without lymph node metastases is 12.5% and 78.6%, respectively. These results show the benefit of stereotactic radiosurgery salvage treatment for advanced, recurrent lesions, without lymph node metastases in previously irradiated head and neck cancer

  17. The value of image coregistration during stereotactic radiosurgery.

    Science.gov (United States)

    Koga, T; Maruyama, K; Igaki, H; Tago, M; Saito, N

    2009-05-01

    Coregistration of any neuroimaging studies into treatment planning for stereotactic radiosurgery became easily applicable using the Leksell Gamma Knife 4C, a new model of gamma knife. The authors investigated the advantage of this image processing. Since installation of the Leksell Gamma Knife 4C at the authors' institute, 180 sessions of radiosurgery were performed. Before completion of planning, coregistration of frameless images of other modalities or previous images was considered to refine planning. Treatment parameters were compared for planning before and after refinement by use of coregistered images. Coregistered computed tomography clarified the anatomical structures indistinct on magnetic resonance imaging. Positron emission tomography visualized lesions disclosing metabolically high activity. Coregistration of prior imaging distinguished progressing lesions from stable ones. Diffusion-tensor tractography was integrated for lesions adjacent to the corticospinal tract or the optic radiation. After refinement of planning in 36 sessions, excess treated volume decreased (p = 0.0062) and Paddick conformity index improved (p < 0.001). Maximal dose to the white matter tracts was decreased (p < 0.001). Image coregistration provided direct information on anatomy, metabolic activity, chronological changes, and adjacent critical structures. This gathered information was sufficiently informative during treatment planning to supplement ambiguous information on stereotactic images, and was useful especially in reducing irradiation to surrounding normal structures.

  18. Radiotherapy Monte Carlo simulation using cloud computing technology.

    Science.gov (United States)

    Poole, C M; Cornelius, I; Trapp, J V; Langton, C M

    2012-12-01

    Cloud computing allows for vast computational resources to be leveraged quickly and easily in bursts as and when required. Here we describe a technique that allows for Monte Carlo radiotherapy dose calculations to be performed using GEANT4 and executed in the cloud, with relative simulation cost and completion time evaluated as a function of machine count. As expected, simulation completion time decreases as 1/n for n parallel machines, and relative simulation cost is found to be optimal where n is a factor of the total simulation time in hours. Using the technique, we demonstrate the potential usefulness of cloud computing as a solution for rapid Monte Carlo simulation for radiotherapy dose calculation without the need for dedicated local computer hardware as a proof of principal.

  19. Continuum variational and diffusion quantum Monte Carlo calculations

    International Nuclear Information System (INIS)

    Needs, R J; Towler, M D; Drummond, N D; Lopez RIos, P

    2010-01-01

    This topical review describes the methodology of continuum variational and diffusion quantum Monte Carlo calculations. These stochastic methods are based on many-body wavefunctions and are capable of achieving very high accuracy. The algorithms are intrinsically parallel and well suited to implementation on petascale computers, and the computational cost scales as a polynomial in the number of particles. A guide to the systems and topics which have been investigated using these methods is given. The bulk of the article is devoted to an overview of the basic quantum Monte Carlo methods, the forms and optimization of wavefunctions, performing calculations under periodic boundary conditions, using pseudopotentials, excited-state calculations, sources of calculational inaccuracy, and calculating energy differences and forces. (topical review)

  20. Radiotherapy Monte Carlo simulation using cloud computing technology

    International Nuclear Information System (INIS)

    Poole, C.M.; Cornelius, I.; Trapp, J.V.; Langton, C.M.

    2012-01-01

    Cloud computing allows for vast computational resources to be leveraged quickly and easily in bursts as and when required. Here we describe a technique that allows for Monte Carlo radiotherapy dose calculations to be performed using GEANT4 and executed in the cloud, with relative simulation cost and completion time evaluated as a function of machine count. As expected, simulation completion time decreases as 1/n for n parallel machines, and relative simulation cost is found to be optimal where n is a factor of the total simulation time in hours. Using the technique, we demonstrate the potential usefulness of cloud computing as a solution for rapid Monte Carlo simulation for radiotherapy dose calculation without the need for dedicated local computer hardware as a proof of principal.

  1. Hearing preservation after low-dose gamma knife radiosurgery of vestibular schwannomas

    International Nuclear Information System (INIS)

    Horiba, Ayako; Hayashi, Motohiro; Chernov, Mikhail; Kawamata, Takakazu; Okada, Yoshikazu

    2016-01-01

    The objective of the retrospective study was to evaluate the factors associated with hearing preservation after low-dose Gamma Knife radiosurgery (GKS) of vestibular schwannomas performed according to the modern standards. From January 2005 to September 2010, 141 consecutive patients underwent such treatment in Tokyo Women's Medical University. Mean marginal dose was 11.9 Gy (range, 11-12 Gy). The doses for the brain stem, cranial nerves (V, VII, and VHIII), and cochlea were kept below 14 Gy, 12 Gy, and 4 Gy, respectively. Out of the total cohort, 102 cases with at least 24 months follow-up were analyzed. Within the median follow-up of 56 months (range, 24-99 months) the crude tumor growth control was 92% (94 cases), whereas its actuarial rate at 5 years was 93%. Out of 49 patients with serviceable hearing on the side of the tumor before GKS, 28 (57%) demonstrated its preservation at the time of the last follow-up. No one evaluated factor, namely Gardner-Robertson hearing class before irradiation, Koos tumor stage, extension of the intrameatal part of the neoplasm up to fundus, nerve of tumor origin, presence of cystic changes in the neoplasm, and cochlea dose demonstrated statistically significant association with preservation of the serviceable hearing after radiosurgery. In conclusion, GKS of vestibular schwannomas performed according to the modern standards of treatment permits to preserve serviceable hearing on the side of the tumor in more than half of the patients. The actual causes of hearing deterioration after radiosurgery remain unclear. (author)

  2. Monte Carlo problem and parallel computers, and how to do a fast particle mover on the STAR 100

    International Nuclear Information System (INIS)

    Sinz, K.H.P.H.

    1975-01-01

    Particle simulation problems of the Monte Carlo type are widely believed to be intrinsically highly scalar problems. In the absence of a definitive mathematical theorem to the contrary, this belief is based on the very apparent programming difficulties encountered on a vector machine. This class of problem is therefore thought to be ill-suited to highly parallel and vectorized computers. However, it is demonstrated by several examples that a particle mover is fully vectorizable. In the case of the CDC STAR 100 it is found that the performance of such a particle mover is not hopeless but hopeful, and is in fact helpful. One of the several possible vectorizations is estimated to yield a gain of a factor of 15 on the STAR over good serial coding on the same machine. This falls far short of the STAR's peak vector performance of 30 to 70 times scalar rates because certain fast vector instructions are not available and have to be simulated. The current STAR algorithm outperforms the carefully handcoded 7600 by a factor of 3. This performance margin is achievable despite the 7600's fivefold superior scalar capability. A more generally vectorized particle mover will always substantially outperform scalar coding on any machine equipped with a properly chosen set of fast vector instructions. (U.S.)

  3. Milagro Version 2 An Implicit Monte Carlo Code for Thermal Radiative Transfer: Capabilities, Development, and Usage

    Energy Technology Data Exchange (ETDEWEB)

    T.J. Urbatsch; T.M. Evans

    2006-02-15

    We have released Version 2 of Milagro, an object-oriented, C++ code that performs radiative transfer using Fleck and Cummings' Implicit Monte Carlo method. Milagro, a part of the Jayenne program, is a stand-alone driver code used as a methods research vehicle and to verify its underlying classes. These underlying classes are used to construct Implicit Monte Carlo packages for external customers. Milagro-2 represents a design overhaul that allows better parallelism and extensibility. New features in Milagro-2 include verified momentum deposition, restart capability, graphics capability, exact energy conservation, and improved load balancing and parallel efficiency. A users' guide also describes how to configure, make, and run Milagro2.

  4. Quality control of radiosurgery: dosimetry with micro camera in spherical mannequin

    International Nuclear Information System (INIS)

    Casado Villalon, F. J.; Navarro Guirado, F.; Garci Pareja, S.; Benitez Villegas, E. M.; Galan Montenegro, P.; Moreno Saiz, C.

    2013-01-01

    The dosimetry of small field is part of quality control in the treatment of cranial radiosurgery. In this work the results of absorbed dose in the isocenter, Planner, with those obtained from are compared experimentally with a micro-camera into an spherical mannequin. (Author)

  5. The parallel processing of EGS4 code on distributed memory scalar parallel computer:Intel Paragon XP/S15-256

    Energy Technology Data Exchange (ETDEWEB)

    Takemiya, Hiroshi; Ohta, Hirofumi; Honma, Ichirou

    1996-03-01

    The parallelization of Electro-Magnetic Cascade Monte Carlo Simulation Code, EGS4 on distributed memory scalar parallel computer: Intel Paragon XP/S15-256 is described. EGS4 has the feature that calculation time for one incident particle is quite different from each other because of the dynamic generation of secondary particles and different behavior of each particle. Granularity for parallel processing, parallel programming model and the algorithm of parallel random number generation are discussed and two kinds of method, each of which allocates particles dynamically or statically, are used for the purpose of realizing high speed parallel processing of this code. Among four problems chosen for performance evaluation, the speedup factors for three problems have been attained to nearly 100 times with 128 processor. It has been found that when both the calculation time for each incident particles and its dispersion are large, it is preferable to use dynamic particle allocation method which can average the load for each processor. And it has also been found that when they are small, it is preferable to use static particle allocation method which reduces the communication overhead. Moreover, it is pointed out that to get the result accurately, it is necessary to use double precision variables in EGS4 code. Finally, the workflow of program parallelization is analyzed and tools for program parallelization through the experience of the EGS4 parallelization are discussed. (author).

  6. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    Energy Technology Data Exchange (ETDEWEB)

    Zankl, M. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Drexler, G. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Petoussi-Henss, N. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Strahlenschutz; Saito, K. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan)

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body`s longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called `remainder`. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  7. The calculation of dose from external photon exposures using reference human phantoms and Monte Carlo methods. Pt. 7. Organ doses due to parallel and environmental exposure geometries

    International Nuclear Information System (INIS)

    Zankl, M.

    1997-03-01

    This report presents a tabulation of organ and tissue equivalent dose as well as effective dose conversion coefficients, normalised to air kerma free in air, for occupational exposures and environmental exposures of the public to external photon radiation. For occupational exposures, whole-body irradiation with idealised geometries, i.e. broad parallel beams and fully isotropic radiation incidence, is considered. The directions of incidence for the parallel beams are anterior-posterior, posterior-anterior, left lateral, right lateral and a full 360 rotation around the body's longitudinal axis. The influence of beam divergence on the body doses is also considered as well as the dependence of effective dose on the angle of radiation incidence. Regarding exposure of the public to environmental sources, three source geometries are considered: exposure from a radioactive cloud, from ground contamination and from the natural radionuclides distributed homogeneously in the ground. The precise angular and energy distributions of the gamma rays incident on the human body were taken into account. The organ dose conversion coefficients given in this catalogue were calculated using a Monte Carlo code simulating the photon transport in mathematical models of an adult male and an adult female, respectively. Conversion coefficients are given for the equivalent dose of 23 organs and tissues as well as for effective dose and the equivalent dose of the so-called 'remainder'. The organ equivalent dose conversion coefficients are given separately for the adult male and female models and - as arithmetic mean of the conversion coefficients of both - for an average adult. Fitted data of the coefficients are presented in tables; the primary raw data as resulting from the Monte Carlo calculation are shown in figures together with the fitted data. (orig.)

  8. Gamma Knife radiosurgery for glomus jugulare tumors: a single-center series of 75 cases.

    Science.gov (United States)

    Ibrahim, Ramez; Ammori, Mohannad B; Yianni, John; Grainger, Alison; Rowe, Jeremy; Radatz, Matthias

    2017-05-01

    OBJECTIVE Glomus jugulare tumors are rare indolent tumors that frequently involve the lower cranial nerves (CNs). Complete resection can be difficult and associated with lower CN injury. Gamma Knife radiosurgery (GKRS) has established its role as a noninvasive alternative treatment option for these often formidable lesions. The authors aimed to review their experience at the National Centre for Stereotactic Radiosurgery, Sheffield, United Kingdom, specifically the long-term tumor control rate and complications of GKRS for these lesions. METHODS Clinical and radiological data were retrospectively reviewed for patients treated between March 1994 and December 2010. Data were available for 75 patients harboring 76 tumors. The tumors in 3 patients were treated in 2 stages. Familial and/or hereditary history was noted in 12 patients, 2 of whom had catecholamine-secreting and/or active tumors. Gamma Knife radiosurgery was the primary treatment modality in 47 patients (63%). The median age at the time of treatment was 55 years. The median tumor volume was 7 cm 3 , and the median radiosurgical dose to the tumor margin was 18 Gy (range 12-25 Gy). The median duration of radiological follow-up was 51.5 months (range 12-230 months), and the median clinical follow-up was 38.5 months (range 6-223 months). RESULTS The overall tumor control rate was 93.4% with low CN morbidity. Improvement of preexisting deficits was noted in 15 patients (20%). A stationary clinical course and no progression of symptoms were noted in 48 patients (64%). Twelve patients (16%) had new symptoms or progression of their preexisting symptoms. The Kaplan-Meier actuarial tumor control rate was 92.2% at 5 years and 86.3% at 10 years. CONCLUSIONS Gamma Knife radiosurgery offers a risk-versus-benefit treatment option with very low CN morbidity and stable long-term results.

  9. The lazaroid U74389G protects normal brain from stereotactic radiosurgery-induced radiation injury

    International Nuclear Information System (INIS)

    Buatti, John M.; Friedman, William A.; Theele, Daniel P.; Bova, Francis J.; Mendenhall, William M.

    1996-01-01

    Purpose: To test an established model of stereotactic radiosurgery-induced radiation injury with pretreatments of either methylprednisolone or the lazaroid U74389G. Methods and Materials: Nine cats received stereotactic radiosurgery with a linear accelerator using an animal radiosurgery device. Each received a dose of 125.0 Gy prescribed to the 84% isodose shell to the anterior limb of the right internal capsule. One animal received no pretreatment, two received citrate vehicle, three received 30 mg/kg of methylprednisolone, and three received 5 mg/kg of U74389G. After irradiation, the animals had frequent neurologic examinations, and neurologic deficits developed in all of them. Six months after the radiation treatment, the animals were anesthetized, and had gadolinium-enhanced magnetic resonance (MR) scans, followed by Evans blue dye perfusion, euthanasia, and brain fixation. Results: Magnetic resonance scans revealed a decrease in the size of the lesions from a mean volume of 0.45 ± 0.06 cm 3 in the control, vehicle-treated, and methylprednisolone-treated animals to 0.22 ± 0.14 cm 3 in the U74389G-treated group. The scans also suggested the absence of necrosis and ventricular dilatation in the lazaroid-treated group. Gross pathology revealed that lesions produced in the untreated, vehicle-treated, and methylprednisolone-treated cats were similar and were characterized by a peripheral zone of Evans blue dye staining with a central zone of a mature coagulative necrosis and focal hemorrhage. However, in the U74389G-treated animals, the lesions were found to have an area of Evans blue dye staining, but lacked discrete areas of necrosis and hemorrhage. Conclusion: These results suggest that the lazaroid U74389G protects the normal brain from radiation injury produced by stereotactic radiosurgery

  10. Concomitant GRID boost for Gamma Knife radiosurgery

    International Nuclear Information System (INIS)

    Ma Lijun; Kwok, Young; Chin, Lawrence S.; Simard, J. Marc; Regine, William F.

    2005-01-01

    We developed an integrated GRID boost technique for Gamma Knife radiosurgery. The technique generates an array of high dose spots within the target volume via a grid of 4-mm shots. These high dose areas were placed over a conventional Gamma Knife plan where a peripheral dose covers the full target volume. The beam weights of the 4-mm shots were optimized iteratively to maximize the integral dose inside the target volume. To investigate the target volume coverage and the dose to the adjacent normal brain tissue for the technique, we compared the GRID boosted treatment plans with conventional Gamma Knife treatment plans using physical and biological indices such as dose-volume histogram (DVH), DVH-derived indices, equivalent uniform dose (EUD), tumor control probabilities (TCP), and normal tissue complication probabilities (NTCP). We found significant increase in the target volume indices such as mean dose (5%-34%; average 14%), TCP (4%-45%; average 21%), and EUD (2%-22%; average 11%) for the GRID boost technique. No significant change in the peripheral dose coverage for the target volume was found per RTOG protocol. In addition, the EUD and the NTCP for the normal brain adjacent to the target (i.e., the near region) were decreased for the GRID boost technique. In conclusion, we demonstrated a new technique for Gamma Knife radiosurgery that can escalate the dose to the target while sparing the adjacent normal brain tissue

  11. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab

  12. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab.

  13. Graphics Processing Unit Accelerated Hirsch-Fye Quantum Monte Carlo

    Science.gov (United States)

    Moore, Conrad; Abu Asal, Sameer; Rajagoplan, Kaushik; Poliakoff, David; Caprino, Joseph; Tomko, Karen; Thakur, Bhupender; Yang, Shuxiang; Moreno, Juana; Jarrell, Mark

    2012-02-01

    In Dynamical Mean Field Theory and its cluster extensions, such as the Dynamic Cluster Algorithm, the bottleneck of the algorithm is solving the self-consistency equations with an impurity solver. Hirsch-Fye Quantum Monte Carlo is one of the most commonly used impurity and cluster solvers. This work implements optimizations of the algorithm, such as enabling large data re-use, suitable for the Graphics Processing Unit (GPU) architecture. The GPU's sheer number of concurrent parallel computations and large bandwidth to many shared memories takes advantage of the inherent parallelism in the Green function update and measurement routines, and can substantially improve the efficiency of the Hirsch-Fye impurity solver.

  14. Stereotactic radiotherapy and radiosurgery in pediatric patients: analysis of indications and outcome

    DEFF Research Database (Denmark)

    Mirza, Bilal; Mønsted, Anne; Jensen, Josephine Harding

    2010-01-01

    We describe indications, outcomes, and risk profiles of fractionated stereotactic radiotherapy (SRT) and single fraction "radiosurgery" (SRS) in pediatric patients compared to the adult population and evaluate the causal role of SRS and SRT in inducing new neurological complications....

  15. The role of stereotactic radiosurgery in the treatment of malignant skull base tumors

    International Nuclear Information System (INIS)

    Miller, Robert C.; Foote, Robert L.; Coffey, Robert J.; Gorman, Deborah A.; Earle, John D.; Schomberg, Paula J.; Kline, Robert W.

    1997-01-01

    Purpose: To determine the efficacy and toxicity of stereotactic radiosurgery in the treatment of malignant skull base tumors. Methods and Materials: Thirty-two patients with 35 newly diagnosed or recurrent malignant skull base tumors ≤33.5 cm 3 were treated using the Leksell Gamma unit. Tumor histologies included: adenoid cystic carcinoma, basal cell carcinoma, chondrosarcoma, chordoma, nasopharyngeal carcinoma, osteogenic sarcoma, and squamous cell carcinoma. Results: After a median follow-up of 2.3 years, 83% ± 15% (±95% confidence interval) of patients experienced a symptomatic response to treatment. Local control at the skull base was 95 ± 9% at 2 years and 78 ± 23% at 3 years. Local-regional control above the clavicles was 75 ± 15% at 1 year and 51 ± 20% at 2 years. Overall and cause specific survival were identical, 82 ± 13% at 1 year, 76 ± 14% at 2 years, and 72 ± 16% at 3 years. One patient developed a radiation-induced optic neuropathy 12 months after radiosurgery. Conclusion: Stereotactic radiosurgery using the Leksell Gamma Unit can provide durable tumor control and symptomatic relief with acceptable toxicity in the majority of patients with malignant tumors 4 cm or less in size involving the skull base. Further evaluation of more patients with longer follow-up is warranted

  16. Stereotactic radiosurgery using the gamma knife for acoustic neuromas

    International Nuclear Information System (INIS)

    Foote, Robert L.; Coffey, Robert J.; Swanson, Jerry W.; Harner, Stephen G.; Beatty, Charles W.; Kline, Robert W.; Stevens, Lorna N.; Hu, Theresa C.

    1995-01-01

    Purpose: To assess the efficacy and toxicity of stereotactic radiosurgery using the gamma knife for acoustic neuromas. Methods and Materials: Between January 1990 and January 1993, 36 patients with acoustic neuromas were treated with stereotactic radiosurgery using the gamma knife. The median maximum tumor diameter was 21 mm (range: 6-32 mm). Tumor volumes encompassed within the prescribed isodose line varied from 266 to 8,667 mm 3 (median: 3,135 mm 3 ). Tumors ≤ 20 mm in maximum diameter received a dose of 20 Gy to the margin, tumors between 21 and 30 mm received 18 Gy, and tumors > 30 mm received 16 Gy. The dose was prescribed to the 50% isodose line in 31 patients and to the 45%, 55%, 60%, 70%, and 80% isodose line in one patient each. The median number of isocenters per tumor was 5 (range: 1-12). Results: At a median follow-up of 16 months (range: 2.5-36 months), all patients were alive. Thirty-five patients had follow-up imaging studies. Nine tumors (26%) were smaller, and 26 tumors (74%) were unchanged. No tumor had progressed. The 1- and 2-year actuarial incidences of facial neuropathy were 52.2% and 66.5%, respectively. The 1- and 2-year actuarial incidences of trigeminal neuropathy were 33.7% and 58.9%, respectively. The 1- and 2-year actuarial incidence of facial or trigeminal neuropathy (or both) was 60.8% and 81.7%, respectively. Multivariate analysis revealed that the following were associated with the time of onset or worsening of facial weakness or trigeminal neuropathy: (a) patients five isocenters. The 1- and 2-year actuarial rates of preservation of useful hearing (Gardner-Robertson class I or II) were 100% and 41.7% ± 17.3, respectively. Conclusion: Stereotactic radiosurgery using the gamma knife provides short-term control of acoustic neuromas when a dose of 16 to 20 Gy to the tumor margin is used. Preservation of useful hearing can be accomplished in a significant proportion of patients

  17. Feasibility of four-dimensional conformal planning for robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, A.; Fisseler, J.; Dieterich, S.; Shiomi, H.; Cleary, K.; Schweikard, A.

    2005-01-01

    Organ motion can have a severe impact on the dose delivered by radiation therapy, and different procedures have been developed to address its effects. Conventional techniques include breath hold methods and gating. A different approach is the compensation for target motion by moving the treatment beams synchronously. Practical results have been reported for robot based radiosurgery, where a linear accelerator mounted on a robotic arm delivers the dose. However, not all organs move in the same way, which results in a relative motion of the beams with respect to the body and the tissues in the proximity of the tumor. This relative motion can severely effect the dose delivered to critical structures. We propose a method to incorporate motion in the treatment planning for robotic radiosurgery to avoid potential overdosing of organs surrounding the target. The method takes into account the motion of all considered volumes, which is discretized for dose calculations. Similarly, the beam motion is taken into account and the aggregated dose coefficient over all discrete steps is used for planning. We simulated the treatment of a moving target with three different planning methods. First, we computed beam weights based on a 3D planning situation and simulated treatment with organ motion and the beams moving synchronously to the target. Second, beam weights were computed by the 4D planning method incorporating the organ and beam motion and treatment was simulated for beams moving synchronously to the target. Third, the beam weights were determined by the 4D planning method with the beams fixed during planning and simulation. For comparison we also give results for the 3D treatment plan if there was no organ motion and when the plan is delivered by fixed beams in the presence of organ motion. The results indicate that the new 4D method is preferable and can further improve the overall conformality of motion compensated robotic radiosurgery

  18. Dosimetric evaluation of proton stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Min, Byung Jun; Shin, Dong Ho; Yoo, Seung Hoon; Jeong, Hojin; Lee, Se Byeong

    2011-01-01

    Surgical excision, conventional external radiotherapy, and chemotherapy could prolong survival in patients with small intracranial tumors. However, surgical excision for meningiomas located in the region of the base of skull or re-resection is often difficult. Moreover, treatment is needed for patients with recurrent tumors or postoperative residual tumors. Conventional external radiotherapy is popular and has significantly increased for treating brain tumors. Stereotactic radiosurgery is an effective alternative treatment technique to microsurgical resection such as benign brain tumor or vestibular Schwannomas. In general, the dose to OAR of 3D conformal plan is lower than that of conformal arc and dynamic conformal arc plans. However, any of OARs was not reached to tolerance dose. Although mean dose of the healthy brain tissue for 3D conformal plan was slightly higher than that of arc plans, the doses of the healthy brain tissue at V10 and V20 were significantly low for dynamic conformal arc plan. The dosimetric differences were the greatest at lower doses. In contrast, 3D conformal plan was better spare at higher doses. In this study, a dosimetric evaluation of proton stereotactic radiosurgery for brain lesion tumors was using fixed and arc beams. A brass block fitted to the PTV structure was modeled for dynamic conformal collimator. Although all treatment plans offer a very good coverage of the PTV, we found that proton arc plans had significantly better conformity to the PTV than static 3D conformal plan. The V20 dose of normal brain for dynamic conformal arc therapy is dramatically reduced compare to those for other therapy techniques.

  19. Development of a parallelization method for KENO V.a

    International Nuclear Information System (INIS)

    Basoglu, B.; Bentley, C.; Dunn, M.

    1995-01-01

    The KENO V.a codes is a widely used Monte carlo codes that is part of the SCALE modular codes system for performing standardized computer analysis of nuclear systems for licensing evaluation. In the past few years, attempts have been made to speed up KENO V.a using new generation computers. In this paper we report on the initial development of a parallel version of KENO V.a for the Kendall Square Research supercomputer (KSRI) at ORNL. Investigations thus far have shown that the parallel code provides accurate results with significantly reduced computation times relative to the conventional KENO V.a code

  20. Monte Carlo codes and Monte Carlo simulator program

    International Nuclear Information System (INIS)

    Higuchi, Kenji; Asai, Kiyoshi; Suganuma, Masayuki.

    1990-03-01

    Four typical Monte Carlo codes KENO-IV, MORSE, MCNP and VIM have been vectorized on VP-100 at Computing Center, JAERI. The problems in vector processing of Monte Carlo codes on vector processors have become clear through the work. As the result, it is recognized that these are difficulties to obtain good performance in vector processing of Monte Carlo codes. A Monte Carlo computing machine, which processes the Monte Carlo codes with high performances is being developed at our Computing Center since 1987. The concept of Monte Carlo computing machine and its performance have been investigated and estimated by using a software simulator. In this report the problems in vectorization of Monte Carlo codes, Monte Carlo pipelines proposed to mitigate these difficulties and the results of the performance estimation of the Monte Carlo computing machine by the simulator are described. (author)

  1. Implementation of a lung radiosurgery program: technical considerations and quality assurance in an Australian institution

    International Nuclear Information System (INIS)

    Siva, Shankar; MacManus, Michael; Ball, David; Chesson, Brent; Aarons, Yolanda; Clements, Natalie; Kron, Tomas

    2012-01-01

    The Peter MacCallum Cancer Centre has established a stereotactic lung radiosurgery program for the treatment of isolated lung metastases. The aim of this study was to critically assess the technical feasibility of performing stereotactic lung radiosurgery in an Australian institution. A single 26-Gy fraction of radiotherapy was delivered to patients with positron emission tomography (PET) staged solitary lung metastases. Motion management was addressed using four-dimensional computed tomographic simulation, and cone beam CT (CBCT) online soft-tissue matching. Treatments were with multiple coplanar and non-coplanar asymmetric beams. Patients were immobilised in a dedicated stereotactic body cradle. Quality assurance (QA) of treatment plans with both ion chamber and film measurements was performed accounting for patient-specific respiratory motion. Between February 2010 and February 2011, nine patients received stereotactic lung radiosurgery. One grade 1 toxicity and one grade 2 toxicity were recorded after treatment. The mean planning target volume was 22.6 cc. A median of eight beams were delivered per treatment plan (range 7–10) with a median of two non-coplanar beams (range 0–6). At treatment plan QA, the difference between planned and delivered dose was ≤1.76% in all static and dynamic ion chamber recordings. A mid-treatment CBCT was performed at a median time of 21 min, with the mean displacement discrepancy from initial set-up being 0.4 mm (range 0–2 mm). Stereotactic radiosurgery to the lung was both feasible and tolerable at our institution. Intrafractional immobilisation within 2 mm was reproducible. Excellent concordance between planned and delivered treatments was achieved in the phantom QA.

  2. The role of radiosurgery in the management of chordoma and chondrosarcoma of the cranial base

    International Nuclear Information System (INIS)

    Kondziolka, D.; Lunsford, L.D.; Flickinger, J.C.

    1991-01-01

    Despite conventional multimodality treatment (surgery and fractionated radiation therapy), recurrence and clinical progression of cranial base chordomas and chondrosarcomas are common. The malignant behavior of these tumors is a result of their critical location, locally aggressive nature, and high recurrence rate. To explore the role of radiosurgery in the treatment of these skull base neoplasms, we assessed its use in four patients with chordoma and two with chondrosarcoma. In five of the patients, radiosurgery was used as adjuvant therapy for residual or recurrent tumors after surgical debulking, and in one patient with a chordoma, it was the primary treatment. No patient received fractionated external beam radiotherapy. All tumors were less than 30 mm in diameter and were treated with 20 Gy to the tumor margin. Skull base computed tomography and magnetic resonance images were essential to define the anatomic relationships between tumor and adjacent basal structures. During follow-up (mean, 22 mo; range, 8-36 mo), the authors found no progression of the treated tumor volume in any patient. Neurological deficits before treatment improved in three patients; the other three patients remained in stable neurological condition. Serial follow-up imaging studies demonstrated that two patients showed reduction in tumor size and four patients had no tumor growth. In one patient, a metastatic parietal lobe chondrosarcoma developed and was treated by microsurgery. Another patient showed tumor progression outside of the radiosurgical treatment volume. The authors results attest to the value of stereotactic radiosurgery as an adjuvant or primary treatment for selected patients with chordoma or chondrosarcoma and demonstrate its potential advantages over standard fractionated irradiation. Analysis of the long-term clinical and imaging effects after radiosurgery is warranted

  3. Gamma knife radiosurgery for typical trigeminal neuralgia: An institutional review of 108 patients

    Science.gov (United States)

    Elaimy, Ameer L.; Lamm, Andrew F.; Demakas, John J.; Mackay, Alexander R.; Lamoreaux, Wayne T.; Fairbanks, Robert K.; Pfeffer, Robert D.; Cooke, Barton S.; Peressini, Benjamin J.; Lee, Christopher M.

    2013-01-01

    Background: In this study, we present the previously unreported pain relief outcomes of 108 patients treated at Gamma Knife of Spokane for typical trigeminal neuralgia (TN) between 2002 and 2011. Methods: Pain relief outcomes were measured using the Barrow Neurological Institute (BNI) pain intensity scale. In addition, the effects gender, age at treatment, pain laterality, previous surgical treatment, repeat Gamma Knife radiosurgery (GKRS), and maximum radiosurgery dose have on patient pain relief outcomes were retrospectively analyzed. Statistical analysis was performed using Andersen 95% confidence intervals, approximate confidence intervals for log hazard ratios, and multivariate Cox proportional hazard models. Results: All 108 patients included in this study were grouped into BNI class IV or V prior to GKRS. The median clinical follow-up time was determined to be 15 months. Following the first GKRS procedure, 71% of patients were grouped into BNI class I-IIIb (I = 31%; II = 3%; IIIa = 19%; IIIb = 18%) and the median duration of pain relief for those patients was determined to be 11.8 months. New facial numbness was reported in 19% of patients and new facial paresthesias were reported in 7% of patients after the first GKRS procedure. A total of 19 repeat procedures were performed on the 108 patients included in this study. Following the second GKRS procedure, 73% of patients were grouped into BNI class I-IIIb (I = 44%; II = 6%; IIIa = 17%, IIIb = 6%) and the median duration of pain relief for those patients was determined to be 4.9 months. For repeat procedures, new facial numbness was reported in 22% of patients and new facial paresthesias were reported in 6% of patients. Conclusions: GKRS is a safe and effective management approach for patients diagnosed with typical TN. However, further studies and supporting research is needed on the effects previous surgical treatment, number of radiosurgery procedures, and maximum radiosurgery dose have on GKRS clinical

  4. Risk factors for neurological complications after acoustic neurinoma radiosurgery: refinement from further experiences

    International Nuclear Information System (INIS)

    Ito, Ken; Shin, Masahiro; Matsuzaki, Masaki; Sugasawa, Keiko; Sasaki, Tomio

    2000-01-01

    Purpose: Further actuarial analyses of neurological complications were performed on a larger population treated by stereotactic radiosurgery at our institution, to establish the optimal treatment parameters. Methods and Materials: Between June 1990 and September 1998, 138 patients with acoustic neurinomas underwent stereotactic radiosurgery at Tokyo University Hospital. Of these, 125 patients who received medical follow-up for 6 months or more entered the present study. Patient ages ranged from 13 to 77 years (median, 53 years). Average tumor diameter ranged from 6.7 to 25.4 mm (mean, 13.9 mm). Maximum tumor doses ranged from 20 to 40 Gy (mean, 29.8 Gy) and peripheral doses from 12 to 25 Gy (mean, 15.4 Gy). One to 12 isocenters were used (median, 4). Follow-up period ranged from 6 to 104 months (median, 37 months). The potential risk factors for neurological complications were analyzed by two univariate and one multivariate actuarial analyses. Neurological complications examined include hearing loss, facial palsy, and trigeminal nerve dysfunction. Variables included in the analyses were four demographic variables, two variables concerning tumor dimensions, and four variables concerning treatment parameters. A variable with significant p values (p < 0.05) on all three actuarial analyses was considered a risk factor. Results: The variables that had significant correlation to increasing the risk for each neurological complication were: Neurofibromatosis Type 2 (NF2) for both total hearing loss and pure tone threshold (PTA) elevation; history of prior surgical resection, tumor size, and the peripheral tumor dose for facial palsy; and the peripheral tumor dose and gender (being female) for trigeminal neuropathy. In facial palsies caused by radiosurgery, discrepancy between the course of palsy and electrophysiological responses was noted. Conclusion: Risk factors for neurological complications seem to have been almost established, without large differences between

  5. Solid craniopharyngiomas treated by stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Backlund, E.-O.

    1979-01-01

    The radiological changes of solid craniopharyngiomas treated by stereotactic radiosurgery have been followed. Nine cases are considered, the patients having received gamma radiation treatment with a dose distribution permitting no part of the tumour to receive doses less than 2-3 Gy. Target doses were 20 to 50 Gy. Tumour shrinkage was registered and no complications which could be attributed with certainty to the irradiation were encountered. The results did not allow an optimal single dose to be determined with accuracy but vaguely indicated that lower doses than those used are sufficient for desired effect on the tumour without jeopardizing its surroundings. (Auth./C.F.)

  6. Monte Carlo simulation methodology for the reliabilty of aircraft structures under damage tolerance considerations

    Science.gov (United States)

    Rambalakos, Andreas

    Current federal aviation regulations in the United States and around the world mandate the need for aircraft structures to meet damage tolerance requirements through out the service life. These requirements imply that the damaged aircraft structure must maintain adequate residual strength in order to sustain its integrity that is accomplished by a continuous inspection program. The multifold objective of this research is to develop a methodology based on a direct Monte Carlo simulation process and to assess the reliability of aircraft structures. Initially, the structure is modeled as a parallel system with active redundancy comprised of elements with uncorrelated (statistically independent) strengths and subjected to an equal load distribution. Closed form expressions for the system capacity cumulative distribution function (CDF) are developed by expanding the current expression for the capacity CDF of a parallel system comprised by three elements to a parallel system comprised with up to six elements. These newly developed expressions will be used to check the accuracy of the implementation of a Monte Carlo simulation algorithm to determine the probability of failure of a parallel system comprised of an arbitrary number of statistically independent elements. The second objective of this work is to compute the probability of failure of a fuselage skin lap joint under static load conditions through a Monte Carlo simulation scheme by utilizing the residual strength of the fasteners subjected to various initial load distributions and then subjected to a new unequal load distribution resulting from subsequent fastener sequential failures. The final and main objective of this thesis is to present a methodology for computing the resulting gradual deterioration of the reliability of an aircraft structural component by employing a direct Monte Carlo simulation approach. The uncertainties associated with the time to crack initiation, the probability of crack detection, the

  7. Spinal Cord Tolerance to Reirradiation With Single-Fraction Radiosurgery: A Swine Model

    Energy Technology Data Exchange (ETDEWEB)

    Medin, Paul M., E-mail: Paul.medin@utsouthwestern.edu [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Foster, Ryan D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States); Kogel, Albert J. van der [Department of Radiation Oncology, Radboud University Medical Center Nijmegen, Nijmegen (Netherlands); Sayre, James W. [Department of Biostatistics and Radiology, University of California Los Angeles, Los Angeles, California (United States); McBride, William H. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California (United States); Solberg, Timothy D. [Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas (United States)

    2012-07-01

    Purpose: This study was performed to determine swine spinal cord tolerance to single-fraction, partial-volume irradiation 1 year after receiving uniform irradiation to 30 Gy in 10 fractions. Methods and Materials: A 10-cm length of spinal cord (C3-T1) was uniformly irradiated to 30 Gy in 10 consecutive fractions and reirradiated 1 year later with a single radiosurgery dose centered within the previously irradiated segment. Radiosurgery was delivered to a cylindrical volume approximately 5 cm in length and 2 cm in diameter, which was positioned laterally to the cervical spinal cord, resulting in a dose distribution with the 90%, 50%, and 10% isodose lines traversing the ipsilateral, central, and contralateral spinal cord, respectively. Twenty-three pigs were stratified into six dose groups with mean maximum spinal cord doses of 14.9 {+-} 0.1 Gy (n = 2), 17.1 {+-} 0.3 Gy (n = 3), 19.0 {+-} 0.1 Gy (n = 5), 21.2 {+-} 0.1 Gy (n = 5), 23.4 {+-} 0.2 Gy (n = 5), and 25.4 {+-} 0.4 Gy (n = 3). The mean percentage of spinal cord volumes receiving {>=}10 Gy for the same groups were 34% {+-} 1%, 40% {+-} 1%, 46% {+-} 3%, 52% {+-} 1%, 56 {+-} 3%, and 57% {+-} 1%. The study endpoint was motor neurologic deficit as determined by a change in gait during a 1- year follow-up period. Results: A steep dose-response curve was observed with a 50% incidence of paralysis (ED{sub 50}) for the maximum point dose of 19.7 Gy (95% confidence interval, 17.4-21.4). With two exceptions, histology was unremarkable in animals with normal neurologic status, while all animals with motor deficits showed some degree of demyelination and focal white matter necrosis on the irradiated side, with relative sparing of gray matter. Histologic comparison with a companion study of de novo irradiated animals revealed that retreatment responders had more extensive tissue damage, including infarction of gray matter, only at prescription doses >20 Gy. Conclusion: Pigs receiving spinal radiosurgery 1 year after

  8. Collision of Physics and Software in the Monte Carlo Application Toolkit (MCATK)

    Energy Technology Data Exchange (ETDEWEB)

    Sweezy, Jeremy Ed [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-21

    The topic is presented in a series of slides organized as follows: MCATK overview, development strategy, available algorithms, problem modeling (sources, geometry, data, tallies), parallelism, miscellaneous tools/features, example MCATK application, recent areas of research, and summary and future work. MCATK is a C++ component-based Monte Carlo neutron-gamma transport software library with continuous energy neutron and photon transport. Designed to build specialized applications and to provide new functionality in existing general-purpose Monte Carlo codes like MCNP, it reads ACE formatted nuclear data generated by NJOY. The motivation behind MCATK was to reduce costs. MCATK physics involves continuous energy neutron & gamma transport with multi-temperature treatment, static eigenvalue (keff and α) algorithms, time-dependent algorithm, and fission chain algorithms. MCATK geometry includes mesh geometries and solid body geometries. MCATK provides verified, unit-test Monte Carlo components, flexibility in Monte Carlo application development, and numerous tools such as geometry and cross section plotters.

  9. Monte Carlo charged-particle tracking and energy deposition on a Lagrangian mesh.

    Science.gov (United States)

    Yuan, J; Moses, G A; McKenty, P W

    2005-10-01

    A Monte Carlo algorithm for alpha particle tracking and energy deposition on a cylindrical computational mesh in a Lagrangian hydrodynamics code used for inertial confinement fusion (ICF) simulations is presented. The straight line approximation is used to follow propagation of "Monte Carlo particles" which represent collections of alpha particles generated from thermonuclear deuterium-tritium (DT) reactions. Energy deposition in the plasma is modeled by the continuous slowing down approximation. The scheme addresses various aspects arising in the coupling of Monte Carlo tracking with Lagrangian hydrodynamics; such as non-orthogonal severely distorted mesh cells, particle relocation on the moving mesh and particle relocation after rezoning. A comparison with the flux-limited multi-group diffusion transport method is presented for a polar direct drive target design for the National Ignition Facility. Simulations show the Monte Carlo transport method predicts about earlier ignition than predicted by the diffusion method, and generates higher hot spot temperature. Nearly linear speed-up is achieved for multi-processor parallel simulations.

  10. Does increased nerve length within the treatment volume improve trigeminal neuralgia radiosurgery? a prospective double-blind, randomized study

    International Nuclear Information System (INIS)

    Flickinger, John C.; Pollock, Bruce E.; Kondziolka, Douglas; Phuong, Loi K.; Foote, Robert L.; Stafford, Scott L.; Lunsford, L. Dade

    2001-01-01

    Purpose: To test the hypothesis that increasing the nerve length within the treatment volume for trigeminal neuralgia radiosurgery would improve pain relief. Methods and Materials: Eighty-seven patients with typical trigeminal neuralgia were randomized to undergo retrogasserian gamma knife radiosurgery (75 Gy maximal dose with 4-mm diameter collimators) using either one (n=44) or two (n=43) isocenters. The median follow-up was 26 months (range 1-36). Results: Pain relief was complete in 57 patients (45 without medication and 12 with low-dose medication), partial in 15, and minimal in another 15 patients. The actuarial rate of obtaining complete pain relief (with or without medication) was 67.7%±5.1%. The pain relief was identical for one- and two-isocenter radiosurgery. Pain relapsed in 30 of 72 responding patients. Facial numbness and mild and severe paresthesias developed in 8, 5, and 1 two-isocenter patients vs. 3, 4, and 0 one-isocenter patients, respectively (p=0.23). Improved pain relief correlated with younger age (p=0.025) and fewer prior procedures (p=0.039) and complications (numbness or paresthesias) correlated with the nerve length irradiated (p=0.018). Conclusions: Increasing the treatment volume to include a longer nerve length for trigeminal neuralgia radiosurgery does not significantly improve pain relief but may increase complications

  11. Tenon hospital 3-D dosimetric methodology for radiosurgery of complex AVMs

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Schlienger, M.; Plazas, M.C.; Laugier, A.

    1990-01-01

    This paper presents the methodology of the irradiation treatment planning for the calculation of the 3-D dose distribution developed at the Tenon Hospital since four years. This dosimetric method is independent of the Linac irradiation technique, thus is can be used with any other type of radiosurgery technique. (author)

  12. Parallel Sequential Monte Carlo for Efficient Density Combination: The Deco Matlab Toolbox

    DEFF Research Database (Denmark)

    Casarin, Roberto; Grassi, Stefano; Ravazzolo, Francesco

    This paper presents the Matlab package DeCo (Density Combination) which is based on the paper by Billio et al. (2013) where a constructive Bayesian approach is presented for combining predictive densities originating from different models or other sources of information. The combination weights...... for standard CPU computing and for Graphical Process Unit (GPU) parallel computing. For the GPU implementation we use the Matlab parallel computing toolbox and show how to use General Purposes GPU computing almost effortless. This GPU implementation comes with a speed up of the execution time up to seventy...... times compared to a standard CPU Matlab implementation on a multicore CPU. We show the use of the package and the computational gain of the GPU version, through some simulation experiments and empirical applications....

  13. Parallel I/O measurements on a SparcCenter and a MEIKO CS2

    International Nuclear Information System (INIS)

    Panzer-Steindel, B.

    1994-01-01

    CERN is participating in a European ESPRIT project (GPMIMD2) to investigate the benefits and future prospects of parallel processing to HEP computing. One of the focal points at CERN is the parallelization of the Monte-Carlo program from the NA48 experiment. This experiment aims to measure the CP-Violation parameters in the neutral kaon system to a very high precision starting in 1996. The Monte-Carlo program (NMC) from the NA48 collaboration consists of 102 subroutines with 17500 lines of FORTRAN code. It simulates the decay of neutral kaons into charged/neutral pions in their detector setup. Their main detector is a liquid krypton calorimeter with about 13000 channels. As the shower simulation of photons and pions in this detector take a long time per event (GEANT), the NMC uses a lookup table (showerlibrary) of previously generated showers

  14. History and future perspectives of the Monte Carlo shell model -from Alphleet to K computer-

    International Nuclear Information System (INIS)

    Shimizu, Noritaka; Otsuka, Takaharu; Utsuno, Yutaka; Mizusaki, Takahiro; Honma, Michio; Abe, Takashi

    2013-01-01

    We report a history of the developments of the Monte Carlo shell model (MCSM). The MCSM was proposed in order to perform large-scale shell-model calculations which direct diagonalization method cannot reach. Since 1999 PC clusters were introduced for parallel computation of the MCSM. Since 2011 we participated the High Performance Computing Infrastructure Strategic Program and developed a new MCSM code for current massively parallel computers such as K computer. We discuss future perspectives concerning a new framework and parallel computation of the MCSM by incorporating conjugate gradient method and energy-variance extrapolation

  15. Impact on cognitive functions following gamma knife radiosurgery for cerebral arteriovenous malformations

    Directory of Open Access Journals (Sweden)

    A Raghunath

    2016-01-01

    Full Text Available Background: Radiosurgery is an alternative to surgical resection of arteriovenous malformation (AVM. Very few studies have addressed the concern of radiation injury to the brain and its attendant adverse effects on cognitive function. Materials and Methods: This prospective study included all patients who underwent gamma knife radiosurgery (GKRS at our institute for cerebral AVM between 2006 and December 2008 (n = 34. All patients underwent neuropsychological evaluation before the procedure. Neuropsychological evaluation was repeated in eighteen patients 2 years following GKRS. Clinical outcome, AVM obliteration, and factors influencing outcome were analyzed in these eighteen patients. Results: Before GKRS, more than 50% had significant impairment of neuropsychological functions compared to normal population norms. 66.6% achieved the excellent radiosurgical outcome. At 2 years follow-up, patients showed varied improvement in neuropsychological function in various categories. Pretherapeutic median value for percentage perseverative responses was 26.5 and at follow-up, it reduced to 18.2 (P = 0.039. Set shifting improved in 11 patients (61.1%, remained same in 5 patients (27.7%, and deteriorated in two patients (11.1%. Patients with a higher Spetzler-Martin grade AVM demonstrated a significantly more favorable shift in follow-up test values for set shifting function (P = 0.021. Patients with postradiation imaging changes had lesser tendency to improve in neuropsychological performance at follow-up. Conclusions: GKRS has no clinically harmful effect on cognitive and neuropsychological functioning in patients with brain AVM. On the contrary, there is an improvement in majority of patients at 2 years following radiosurgery when nidus is obliterated.

  16. Impact on cognitive functions following gamma knife radiosurgery for cerebral arteriovenous malformations.

    Science.gov (United States)

    Raghunath, A; Bennett, Niranjana; Arimappamagan, Arivazhagan; Bhat, Dhananjaya I; Srinivas, Dwarakanath; Thennarasu, K; Jamuna, R; Somanna, Sampath

    2016-01-01

    Radiosurgery is an alternative to surgical resection of arteriovenous malformation (AVM). Very few studies have addressed the concern of radiation injury to the brain and its attendant adverse effects on cognitive function. This prospective study included all patients who underwent gamma knife radiosurgery (GKRS) at our institute for cerebral AVM between 2006 and December 2008 (n = 34). All patients underwent neuropsychological evaluation before the procedure. Neuropsychological evaluation was repeated in eighteen patients 2 years following GKRS. Clinical outcome, AVM obliteration, and factors influencing outcome were analyzed in these eighteen patients. Before GKRS, more than 50% had significant impairment of neuropsychological functions compared to normal population norms. 66.6% achieved the excellent radiosurgical outcome. At 2 years follow-up, patients showed varied improvement in neuropsychological function in various categories. Pretherapeutic median value for percentage perseverative responses was 26.5 and at follow-up, it reduced to 18.2 (P = 0.039). Set shifting improved in 11 patients (61.1%), remained same in 5 patients (27.7%), and deteriorated in two patients (11.1%). Patients with a higher Spetzler-Martin grade AVM demonstrated a significantly more favorable shift in follow-up test values for set shifting function (P = 0.021). Patients with postradiation imaging changes had lesser tendency to improve in neuropsychological performance at follow-up. GKRS has no clinically harmful effect on cognitive and neuropsychological functioning in patients with brain AVM. On the contrary, there is an improvement in majority of patients at 2 years following radiosurgery when nidus is obliterated.

  17. Stepwise multi-criteria optimization for robotic radiosurgery

    International Nuclear Information System (INIS)

    Schlaefer, A.; Schweikard, A.

    2008-01-01

    Achieving good conformality and a steep dose gradient around the target volume remains a key aspect of radiosurgery. Clearly, this involves a trade-off between target coverage, conformality of the dose distribution, and sparing of critical structures. Yet, image guidance and robotic beam placement have extended highly conformal dose delivery to extracranial and moving targets. Therefore, the multi-criteria nature of the optimization problem becomes even more apparent, as multiple conflicting clinical goals need to be considered coordinate to obtain an optimal treatment plan. Typically, planning for robotic radiosurgery is based on constrained optimization, namely linear programming. An extension of that approach is presented, such that each of the clinical goals can be addressed separately and in any sequential order. For a set of common clinical goals the mapping to a mathematical objective and a corresponding constraint is defined. The trade-off among the clinical goals is explored by modifying the constraints and optimizing a simple objective, while retaining feasibility of the solution. Moreover, it becomes immediately obvious whether a desired goal can be achieved and where a trade-off is possible. No importance factors or predefined prioritizations of clinical goals are necessary. The presented framework forms the basis for interactive and automated planning procedures. It is demonstrated for a sample case that the linear programming formulation is suitable to search for a clinically optimal treatment, and that the optimization steps can be performed quickly to establish that a Pareto-efficient solution has been found. Furthermore, it is demonstrated how the stepwise approach is preferable compared to modifying importance factors

  18. Analysis of neurological sequelae from radiosurgery of arteriovenous malformations: how location affects outcome

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Maitz, Ann H.; Lunsford, L. Dade

    1998-01-01

    Purpose/Objective: To elucidate how the risks of developing temporary and permanent neurological sequelae from radiosurgery for arteriovenous malformations (AVM) are related to AVM location, the addition of stereotactic magnetic resonance (MR) imaging to angiographic targeting, and prior hemorrhage or neurological deficits. Materials and Methods: We evaluated follow-up imaging and clinical data in 332 AVM patients who received gamma knife radiosurgery at the University of Pittsburgh between 1987 and 1994. All patients had regular clinical or imaging follow-up for a minimum of 2 years (range: 24-96 months, median = 45 months). There were 83 patients with MR-assisted planning, 187 with prior hemorrhages, and 143 with prior neurological deficits. Results: Symptomatic postradiosurgery sequelae (any neurological problem including headache) developed in 30 (9%) of 332 patients. Symptoms resolved in 58% of patients within 27 months with a significantly greater proportion (p = 0.006) resolving in patients with Dmin 0.3), including the addition of MR targeting, average radiation dose in 20 cc, prior hemorrhage, or neurological deficit. We used these results to construct a risk prediction model for symptomatic postradiosurgery sequelae. The risk of radiation necrosis was significantly correlated with PIE score (p < 0.048), but not with 12-Gy volume. Conclusion: The risks of developing complications from AVM radiosurgery can be predicted according to location with the PIE score, in conjunction with the 12-Gy treatment volume. Further study of factors affecting persistence of these sequelae (progression to radiation necrosis) is needed

  19. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  20. Experience in cervix intraepithelial neoplasia and the in situ carcinoma with radiosurgery

    International Nuclear Information System (INIS)

    Fajardo Tornes, Yarine; Lau Serrano, Dalgis; Perez Ramirez Fernando

    2010-01-01

    To expose the results from a longitudinal, prospective and descriptive study conducted in 1 437 patients diagnosed with cervical intraepithelial neoplasm (CIN) and in situ carcinoma (ISC) treated by radiosurgery in the neck pathology consultation of the 'Carlos Manuel de Cespedes' University Provincial Hospital during 2004-2009

  1. Historia magistra vitae (Cic. De or. 2.36). The Prime Objective of Radiosurgery in Acoustic Neurinomas.

    Science.gov (United States)

    Valentino, V; Benassi, M; Strigari, L

    2006-11-30

    The central question of stereotaxic radiosurgery in acoustic neurinomas is how to pinpoint its main objective: is it a better alternative to neurosurgery or an option when surgery is unfeasible? This study is a continuation of the article published in 1995 in Acta Neurochirurgica, but benefits from greater experience, more complete analysis and longer supervision of results. The conclusions that can be drawn to date from our own findings and from others in the literature are the following: radiosurgery can be used not only to prevent neurinoma growth and at the same time to preserve the patient's neurological conditions without the risk of complications, but it can also be counted on to provide a cure. However, radiosurgery as an excising device is more insidious than the microsurgical scalpel, since the narrow beam of radiation, directed to a limited target without opening the skull, is invisible. The expression coined by Lars Leksell regarded precisely the innovation he himself conceived in the 'closed skull operation', with reference to its use in cases of acoustic neurinoma as an alternative to traditional surgery. Hence, whatever technique or instruments are involved, it is always a question of interventional neuroradiology or minimally invasive neurosurgery.

  2. Introduction results of radiosurgery technique in cervical pathology consultation. Analysis of five years 2004 – 2009.

    Directory of Open Access Journals (Sweden)

    Rafael E. Pérez Castro

    2011-06-01

    Full Text Available AA cross sectional study and retrospective was performed in patients having cervical intraepithelial neoplasia (CIN, mainly in high grade lesions (CIN II, CIN III and C. In situ, which were treated with radiosurgery technique in the University General Hospital “Camilo Cienfuegos” Sancti Spiritus during the period may 2004 – may 2009 with the objective to evaluate the radiosurgery`s behaviour in the period mentioned before. The studied group was conformed by 550 patients having high grade lesions and low grade persistent lesions (NIC I with previous biopsy, a smaller group of 24 cases was formed by benign pathologies tributary of this procedure. High grade lesions were of major indications (73.1%. 69 cases were false negative (13.3%; since the second decade of life were presented high and low grade lesions of cervical pathology, a good correlation punch – cone byopsy was checked; edges of the surgical section behave properly, lower than what it is established in the international standard (6.7. The procedure had a great economic and social impact, because it is an ambulatory technique with few difficulties, low cost, and a fast integration patient – normal work.

  3. Gamma Knife radiosurgery in pituitary adenomas: Why, who, and how to treat?

    Science.gov (United States)

    Castinetti, Frederic; Brue, Thierry

    2010-08-01

    Pituitary adenomas are benign tumors that can be either secreting (acromegaly, Cushing's disease, prolactinomas) or non-secreting. Transsphenoidal neurosurgery is the gold standard treatment; however, it is not always effective. Gamma Knife radiosurgery is a specific modality of stereotactic radiosurgery, a precise radiation technique. Several studies reported the efficacy and low risk of adverse effects induced by this technique: in secreting pituitary adenomas, hypersecretion is controlled in about 50% of cases and tumor volume is stabilized or decreased in 80-90% of cases, making Gamma Knife a valuable adjunctive or first-line treatment. As hormone levels decrease progressively, the main drawback is the longer time to remission (12-60 months), requiring an additional treatment during this period. Hypopituitarism is the main side effect, observed in 20-40% cases. Gamma Knife is thus useful in the therapeutic algorithms of pituitary adenomas in well-defined indications, mainly low secreting small lesions well identified on magnetic resonance imaging (MRI).

  4. Monte Carlo and Quasi-Monte Carlo Sampling

    CERN Document Server

    Lemieux, Christiane

    2009-01-01

    Presents essential tools for using quasi-Monte Carlo sampling in practice. This book focuses on issues related to Monte Carlo methods - uniform and non-uniform random number generation, variance reduction techniques. It covers several aspects of quasi-Monte Carlo methods.

  5. Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors

    International Nuclear Information System (INIS)

    Somigliana, A.; Borelli, S.; Zonca, G.; Pignoli, E.; Loi, G.; Marchesini, R.; Cattaneo, G.M.; Fiorino, C.; Vecchio, A. del; Calandrino, R.

    1999-01-01

    In stereotactic radiosurgery the choice of appropriate detectors, whether for absolute or relative dosimetry, is very important due to the steep dose gradient and the incomplete lateral electronic equilibrium. For both linac-based and Leksell Gamma Knife radiosurgery units, we tested the use of calibrated radiochromic film to measure absolute doses and relative dose distributions. In addition a small diode was used to estimate the relative output factors. The data obtained using radiochromic and diode detectors were compared with measurements performed with other conventional methods of dosimetry, with calculated values by treatment planning systems and with data prestored in the treatment planning system supplied by the Leksell Gamma Knife (LGK) vendor. Two stereotactic radiosurgery techniques were considered: Leksell Gamma Knife (using γ-rays from 60 Co) and linac-based radiosurgery (LR) (6 MV x-rays). Different detectors were used for both relative and absolute dosimetry: relative output factors (OFs) were estimated by using radiochromic and radiographic films and a small diode; relative dose distributions in the axial and coronal planes of a spherical polystyrene phantom were measured using radiochromic film and calculated by two different treatment planning systems (TPSs). The absolute dose at the sphere centre was measured by radiochromic film and a small ionization chamber. An accurate selection of radiochromic film was made: samples of unexposed film showing a percentage standard deviation of less than 3% were used for relative dose profiles, and for absolute dose and OF evaluations this value was reduced to 1.5%. Moreover a proper calibration curve was made for each set of measurements. With regard to absolute doses, the results obtained with the ionization chamber are in good correlation with radiochromic film-generated data, for both LGK and LR, showing a dose difference of less than 1%. The output factor evaluations, performed using different methods

  6. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems

    International Nuclear Information System (INIS)

    Paelinck, L; Reynaert, N; Thierens, H; Neve, W De; Wagter, C de

    2005-01-01

    The purpose of this study was to assess the absorbed dose in and around lung tissue by performing radiochromic film measurements, Monte Carlo simulations and calculations with superposition convolution algorithms. We considered a layered polystyrene phantom of 12 x 12 x 12 cm 3 containing a central cavity of 6 x 6 x 6 cm 3 filled with Gammex RMI lung-equivalent material. Two field configurations were investigated, a small 1 x 10 cm 2 field and a larger 10 x 10 cm 2 field. First, we performed Monte Carlo simulations to investigate the influence of radiochromic film itself on the measured dose distribution when the film intersects a lung-equivalent region and is oriented parallel to the central beam axis. To that end, the film and the lung-equivalent materials were modelled in detail, taking into account their specific composition. Next, measurements were performed with the film oriented both parallel and perpendicular to the central beam axis to verify the results of our Monte Carlo simulations. Finally, we digitized the phantom in two commercially available treatment planning systems, Helax-TMS version 6.1A and Pinnacle version 6.2b, and calculated the absorbed dose in the phantom with their incorporated superposition convolution algorithms to compare with the Monte Carlo simulations. Comparing Monte Carlo simulations with measurements reveals that radiochromic film is a reliable dosimeter in and around lung-equivalent regions when the film is positioned perpendicular to the central beam axis. Radiochromic film is also able to predict the absorbed dose accurately when the film is positioned parallel to the central beam axis through the lung-equivalent region. However, attention must be paid when the film is not positioned along the central beam axis, in which case the film gradually attenuates the beam and decreases the dose measured behind the cavity. This underdosage disappears by offsetting the film a few centimetres. We find deviations of about 3.6% between

  7. Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems

    Science.gov (United States)

    Paelinck, L.; Reynaert, N.; Thierens, H.; DeNeve, W.; DeWagter, C.

    2005-05-01

    The purpose of this study was to assess the absorbed dose in and around lung tissue by performing radiochromic film measurements, Monte Carlo simulations and calculations with superposition convolution algorithms. We considered a layered polystyrene phantom of 12 × 12 × 12 cm3 containing a central cavity of 6 × 6 × 6 cm3 filled with Gammex RMI lung-equivalent material. Two field configurations were investigated, a small 1 × 10 cm2 field and a larger 10 × 10 cm2 field. First, we performed Monte Carlo simulations to investigate the influence of radiochromic film itself on the measured dose distribution when the film intersects a lung-equivalent region and is oriented parallel to the central beam axis. To that end, the film and the lung-equivalent materials were modelled in detail, taking into account their specific composition. Next, measurements were performed with the film oriented both parallel and perpendicular to the central beam axis to verify the results of our Monte Carlo simulations. Finally, we digitized the phantom in two commercially available treatment planning systems, Helax-TMS version 6.1A and Pinnacle version 6.2b, and calculated the absorbed dose in the phantom with their incorporated superposition convolution algorithms to compare with the Monte Carlo simulations. Comparing Monte Carlo simulations with measurements reveals that radiochromic film is a reliable dosimeter in and around lung-equivalent regions when the film is positioned perpendicular to the central beam axis. Radiochromic film is also able to predict the absorbed dose accurately when the film is positioned parallel to the central beam axis through the lung-equivalent region. However, attention must be paid when the film is not positioned along the central beam axis, in which case the film gradually attenuates the beam and decreases the dose measured behind the cavity. This underdosage disappears by offsetting the film a few centimetres. We find deviations of about 3.6% between

  8. Monte Carlo method for neutron transport calculations in graphics processing units (GPUs)

    International Nuclear Information System (INIS)

    Pellegrino, Esteban

    2011-01-01

    Monte Carlo simulation is well suited for solving the Boltzmann neutron transport equation in an inhomogeneous media for complicated geometries. However, routine applications require the computation time to be reduced to hours and even minutes in a desktop PC. The interest in adopting Graphics Processing Units (GPUs) for Monte Carlo acceleration is rapidly growing. This is due to the massive parallelism provided by the latest GPU technologies which is the most promising solution to the challenge of performing full-size reactor core analysis on a routine basis. In this study, Monte Carlo codes for a fixed-source neutron transport problem were developed for GPU environments in order to evaluate issues associated with computational speedup using GPUs. Results obtained in this work suggest that a speedup of several orders of magnitude is possible using the state-of-the-art GPU technologies. (author) [es

  9. Target delineation in radiosurgery for cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Guo, W.Y.; Nordell, B.; Karlsson, B.; Soederman, M.; Lindqvist, M.; Ericson, K.; Franck, A.; Lax, I.; Lindquist, C.

    1993-01-01

    A study of 6 selected arteriovenous malformation (AVM) patients was performed to investigate the feasibility of delineating an AVM on MR images and to compare the AVM volume outlined on different images. Conventional stereotaxic angiograms, stereotaxic MR images and MR angiograms using several different pulse sequences were obtained prior to radiosurgery. Treatment plans were made from the conventional stereotaxic angiograms. These plans were then transferred to a separate dose planning computer which displayed the MR images with the superimposed isodose lines. The radiated volumes of AVM and brain tissue were measured from these MR images. Last, an assessment was made of the radiation volume needed for an appropriate treatment of the AVM if the treatment plan was made from the MR images rather than from the conventional stereotaxic angiogram. It was possible to delineate medium and large size AVM nidi on stereotaxic MR images based on an integration of information obtained from various pulse sequences. The estimated volumes of the AVM nidi were found to be larger on the conventional stereotaxic angiograms than on the stereotaxic MR images. Consequently, a dose plan based on a conventional stereotaxic angiogram would result in a higher integral dose to the brain with the same target dose. By using reliable MR information it is expected that the volume of brain exposed to radiation could be decreased and the adverse effects of stereotactic radiosurgery for AVM thereby minimized. (orig.)

  10. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  11. Gamma knife radiosurgery of acoustic neurinomas

    International Nuclear Information System (INIS)

    Bertalanffy, A.; Dietrich, W.; Aichholzer, M.; Kitz, K.; Heimberger, K.; Brix, R.

    2001-01-01

    The authors report on their series of 40 patients with 41 acoustic neurinomas (ACNs), including one patient with bilateral acoustic neurinomas suffering from neurofibromatosis type 2 (NF II) who were treated with the gamma knife unit at their institution between August 1992 and October 1995. Of these 41 tumours, 21 ACNs had been operated on before (l to 4 times), 20 ACNs were exclusively treated by gamma knife radiosurgery (GKRS). The maximal axial tumour diameter ranged from 6 to 33 mm (median: 25 mm), the maximal transverse tumour diameter ranged from 7 mm to 36 mm (median: 16 mm). The dose distributed to the tumour margin was 10 to 17 Gy (median: 12 Gy) by enclosing the tumour with the 40 % to 95 % isodose line (median: 50 % isodose line) and using 1 to 12 isocenters (median: 5 isocenters). Central loss of contrast enhancement was observed in 78 % of the patients within six to 12 months after radiosurgery. Thirty-two patients were observed over a minimum follow up period of at least 36 months, 9 patients were lost to follow up as they died of unrelated causes or refused further check-ups. Within the follow up period of up to seven years, magnetic resonance imaging (MRI) control scans revealed the tumour diameter stable or decreased in 29 cases and increased in three tumours. Of 14 patients with useful hearing before treatment, 9 patients were examined in addition to pure tone audiogramm by measurement of brainstem auditory evoked potentials (BAEPs) one to four years after radiosurgery. None of three patients showed a postoperative loss of the cochlea function. According to slight alterations of the cochlea function (cochlea summating action potential), pure tone audiometry of those patients revealed only slight changes of the hearing level (HL) within a maximum range of ±15 Decibel (dB). The hearing threshold improved in two, was stable in four and deteriorated in three patients, respectively. We observed postradiosurgical aggravation of a pre-existing facial

  12. Gamma knife radiosurgery of acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Bertalanffy, A; Dietrich, W; Aichholzer, M; Kitz, K [Department of Neurosurgery, University of Vienna, Medical School, Vienna (Austria); Heimberger, K [Department of Radiology, Division: Neuroradiology, University of Vienna, Medical School, Vienna (Austria); Brix, R [Department of Otorhinolaryngology, University of Vienna, Medical School, Vienna (Austria)

    2001-07-01

    The authors report on their series of 40 patients with 41 acoustic neurinomas (ACNs), including one patient with bilateral acoustic neurinomas suffering from neurofibromatosis type 2 (NF II) who were treated with the gamma knife unit at their institution between August 1992 and October 1995. Of these 41 tumours, 21 ACNs had been operated on before (l to 4 times), 20 ACNs were exclusively treated by gamma knife radiosurgery (GKRS). The maximal axial tumour diameter ranged from 6 to 33 mm (median: 25 mm), the maximal transverse tumour diameter ranged from 7 mm to 36 mm (median: 16 mm). The dose distributed to the tumour margin was 10 to 17 Gy (median: 12 Gy) by enclosing the tumour with the 40 % to 95 % isodose line (median: 50 % isodose line) and using 1 to 12 isocenters (median: 5 isocenters). Central loss of contrast enhancement was observed in 78 % of the patients within six to 12 months after radiosurgery. Thirty-two patients were observed over a minimum follow up period of at least 36 months, 9 patients were lost to follow up as they died of unrelated causes or refused further check-ups. Within the follow up period of up to seven years, magnetic resonance imaging (MRI) control scans revealed the tumour diameter stable or decreased in 29 cases and increased in three tumours. Of 14 patients with useful hearing before treatment, 9 patients were examined in addition to pure tone audiogramm by measurement of brainstem auditory evoked potentials (BAEPs) one to four years after radiosurgery. None of three patients showed a postoperative loss of the cochlea function. According to slight alterations of the cochlea function (cochlea summating action potential), pure tone audiometry of those patients revealed only slight changes of the hearing level (HL) within a maximum range of {+-}15 Decibel (dB). The hearing threshold improved in two, was stable in four and deteriorated in three patients, respectively. We observed postradiosurgical aggravation of a pre-existing facial

  13. PRELIMINARY COUPLING OF THE MONTE CARLO CODE OPENMC AND THE MULTIPHYSICS OBJECT-ORIENTED SIMULATION ENVIRONMENT (MOOSE) FOR ANALYZING DOPPLER FEEDBACK IN MONTE CARLO SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Matthew Ellis; Derek Gaston; Benoit Forget; Kord Smith

    2011-07-01

    In recent years the use of Monte Carlo methods for modeling reactors has become feasible due to the increasing availability of massively parallel computer systems. One of the primary challenges yet to be fully resolved, however, is the efficient and accurate inclusion of multiphysics feedback in Monte Carlo simulations. The research in this paper presents a preliminary coupling of the open source Monte Carlo code OpenMC with the open source Multiphysics Object-Oriented Simulation Environment (MOOSE). The coupling of OpenMC and MOOSE will be used to investigate efficient and accurate numerical methods needed to include multiphysics feedback in Monte Carlo codes. An investigation into the sensitivity of Doppler feedback to fuel temperature approximations using a two dimensional 17x17 PWR fuel assembly is presented in this paper. The results show a functioning multiphysics coupling between OpenMC and MOOSE. The coupling utilizes Functional Expansion Tallies to accurately and efficiently transfer pin power distributions tallied in OpenMC to unstructured finite element meshes used in MOOSE. The two dimensional PWR fuel assembly case also demonstrates that for a simplified model the pin-by-pin doppler feedback can be adequately replicated by scaling a representative pin based on pin relative powers.

  14. SU-F-SPS-09: Parallel MC Kernel Calculations for VMAT Plan Improvement

    International Nuclear Information System (INIS)

    Chamberlain, S; French, S; Nazareth, D

    2016-01-01

    Purpose: Adding kernels (small perturbations in leaf positions) to the existing apertures of VMAT control points may improve plan quality. We investigate the calculation of kernel doses using a parallelized Monte Carlo (MC) method. Methods: A clinical prostate VMAT DICOM plan was exported from Eclipse. An arbitrary control point and leaf were chosen, and a modified MLC file was created, corresponding to the leaf position offset by 0.5cm. The additional dose produced by this 0.5 cm × 0.5 cm kernel was calculated using the DOSXYZnrc component module of BEAMnrc. A range of particle history counts were run (varying from 3 × 10"6 to 3 × 10"7); each job was split among 1, 10, or 100 parallel processes. A particle count of 3 × 10"6 was established as the lower range because it provided the minimal accuracy level. Results: As expected, an increase in particle counts linearly increases run time. For the lowest particle count, the time varied from 30 hours for the single-processor run, to 0.30 hours for the 100-processor run. Conclusion: Parallel processing of MC calculations in the EGS framework significantly decreases time necessary for each kernel dose calculation. Particle counts lower than 1 × 10"6 have too large of an error to output accurate dose for a Monte Carlo kernel calculation. Future work will investigate increasing the number of parallel processes and optimizing run times for multiple kernel calculations.

  15. A theoretical analysis of hemodynamic and biomechanical alterations in intracranial AVMs after radiosurgery

    International Nuclear Information System (INIS)

    Lo, E.H.

    1993-01-01

    Stereotactic radiosurgery is being increasingly used to treat intracranial arteriovenous malformations (AVMs). However, successful radiosurgery may involve latent periods of 1-2 years prior to AVM obliteration. This latent period include states of altered flow patterns that may not influence hemorrhage probabilities. The probability of hemorrhage is likely to be related to the degree of biomechanical stress across the AVM shunt walls. This paper describes a theoretical analysis of the altered hemodynamics and biomechanical stresses within AVM shunts post-radiosurgery. The mathematical model is comprised of linked flow compartments that represent the AVM and adjacent normal vasculature. As obliteration of the irradiated shunts occurs, changes in flow rates and pressure gradients are calculated based on first order fluid dynamics. Stress on the AVM shunt walls is calculated based on tangential forces due to intramural pressure. Two basic models are presented: a distribution of shunts with fixed thin walls subject to step-function obliteration, and a distribution of shunts subject to luminal obliteration from slowly thickening walls. Variations on these models are analyzed, including sequential, selective and random shunt obliteration, and uniform or Poisson distributions of shunt radii. Model I reveals that the range of pressure alterations in the radiosurgically-treated AVM include the possibility of transient increases in the total biomechanical stress within the shunt walls prior to obliteration. Model II demonstrates that uniform luminal narrowing via thickened walls should lead to reduced transmural stresses. The precise temporal pattern of AVM flow decrease and biomechanical stress reduction depends on the selection of shunts that are obliterated. 34 refs., 5 figs., 1 tab

  16. Radiosurgery for Para-IAC Meningiomas: The Effect of Radiation Dose to the Cochlea on Hearing Outcome

    International Nuclear Information System (INIS)

    Kim, Young-Hoon; Kim, Dong Gyu; Han, Jung Ho; Chung, Hyun-Tai; Kim, In Kyung; Song, Sang Woo; Park, Jeong-Hoon; Kim, Jin Wook; Kim, Yong Hwy; Park, Chul-Kee; Kim, Chae-Yong; Paek, Sun Ha; Jung, Hee-Won

    2012-01-01

    Purpose: This study was performed to assess the radiosurgical results of meningiomas extending into the internal acoustic canal (para-IAC meningiomas), with a particular focus on the effect of radiation dose to the cochlea on hearing outcome. Methods and Materials: A total of 50 patients who underwent radiosurgery for para-IAC meningiomas between 1998 and 2009, which were followed for 2 years, were enrolled. The mean age was 55.8 years (range, 15–75). The mean tumor volume was 6.1 cm 3 (range, 1.0–19.0), the mean tumor length in the IAC was 6.9 mm (range, 1.3–13.3), and the mean prescribed marginal dose was 13.1 Gy (range, 10–15) at an isodose line of 50%. The mean follow-up duration was 46 months (range, 24–122). Results: Eight (16.0%) patients had nonserviceable hearing at the time of surgery. At the last follow-up, the tumor control rate was 94%; unchanged in 17 patients, decreased in 30 patients, and increased in 3 patients. Among 42 patients with serviceable hearing at the time of radiosurgery, it was preserved in 41 (97.6%) patients at the last follow-up. The maximal and mean radiation doses to the cochleae of these 41 patients were 5.8 Gy ± 0.3 (range, 3.1–11.5) and 4.3 Gy ± 0.2 (range, 2.2–7.5), respectively. The maximal dose to the cochlea of the patient who lost hearing after radiosurgery was 4.7 Gy. Conclusions: The radiation dose to the cochlea may have the minimal toxic effect on the hearing outcome in patients who undergo radiosurgery for para-IAC meningiomas.

  17. Peritumoral hemorrhage immediately after radiosurgery for metastatic brain tumor

    International Nuclear Information System (INIS)

    Uchino, Masafumi; Kitajima, Satoru; Miyazaki, Chikao; Otsuka, Takashi; Seiki, Yoshikatsu; Shibata, Iekado

    2003-01-01

    We report a case of a 44-year-old woman with metastatic brain tumors who suffered peri-tumoral hemorrhage soon after stereotactic radiosurgery (SRS). She had been suffering from breast cancer with multiple systemic metastasis. She started to have headache, nausea, dizziness and speech disturbance 1 month before admission. There was no bleeding tendency in the hematological examination and the patient was normotensive. Neurological examination disclosed headache and slightly aphasia. Magnetic resonance imaging showed a large round mass lesion in the left temporal lobe. It was a well-demarcated, highly enhanced mass, 45 mm in diameter. SRS was performed on four lesions in a single session (Main mass: maximum dose was 30 Gy in the center and 20 Gy in the margin of the tumor. Others: maximum 25 Gy margin 20 Gy). After radiosurgery, she had severe headache, nausea and vomiting and showed progression of aphasia. CT scan revealed a peritumoral hemorrhage. Conservative therapy was undertaken and the patient's symptoms improved. After 7 days, she was discharged, able to walk. The patient died of extensive distant metastasis 5 months after SRS. Acute transient swelling following conventional radiotherapy is a well-documented phenomenon. However, the present case indicates that such an occurrence is also possible in SRS. We have hypothesized that acute reactions such as brain swelling occur due to breakdown of the fragile vessels of the tumor or surrounding tissue. (author)

  18. Management of supratentorial cavernous malformations: craniotomy versus gammaknife radiosurgery.

    Science.gov (United States)

    Shih, Yang-Hsin; Pan, David Hung-Chi

    2005-02-01

    Although craniotomy is the preferred treatment for symptomatic solitary supratentorial cavernous malformation (CM), radiosurgery is also an option. Our aim was to see which of these strategies was the most effective and under what circumstances. Of the 46 patients with solitary supratentorial CM that we retrospectively studied, 24 presented with seizures, 16 with focal neurological deficits due to intracerebral hemorrhage, and 6 with both seizures and bleeding. Sixteen were treated with craniotomy and 30 with gammaknife radiosurgery (GKRS). The main outcome measures for comparing craniotomy with GKRS were the proportion of postoperative seizure-free patients and the proportion of patients in whom no rebleeding occurred. Of patients presenting with seizures with/without bleeding, a significantly higher proportion of the craniotomy group than the GKRS group became and remained seizure-free (11/14 [79%] versus 4/16 [25%]; P < 0.002), and of those presenting with bleeding with/without seizures, a somewhat (though nonsignificantly) higher proportion did not rebleed (4/4 [100%] versus 12/18 [67%]) after surgery. The remaining 2 of the 16 craniotomy patients did not rebleed and had no residual tumor at follow up. Twelve of the 30 GKRS patients had evidence of tumor regression at follow up. In the clinical management of solitary supratentorial CM, craniotomy for lesionectomy resulted in better seizure control and rebleeding avoidance than GKRS.

  19. Motion detection system with GPU acceleration for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Usui, Keisuke; Kunieda, Etsuo; Shigematsu, Naoyuki

    2012-01-01

    Stereotactic radiosurgery is a non-invasive method for the treatment of tumors that employs a narrow, high-energy X-ray beam. In this form of therapy, the target region is intensively irradiated with the narrow beam, and any unexpected patient motion may therefore lead to undesirable irradiation of neighboring normal tissues and organs. To overcome this problem, we propose a contactless motion detection system with three USB cameras for use in stereotactic radiosurgery of the head and neck. In our system, the three cameras monitor images of the patient's nose and ears, and patient motion is detected using a template-matching method. If patient motion is detected, the system alerts the radiologist to turn off the beam. We reduced the effects of variations in the lighting in the irradiation room by employing USB cameras sensitive to infrared light. To detect movement in the acquired images, we use a template-matching method that is realized with general-purpose computing-on-graphics processing units. In this paper, we present an outline of our proposed motion detection system based on monitoring of images of the patient acquired with infrared USB cameras and a template-matching method. The performance of the system was evaluated under the same conditions as those used in actual radiation therapy of the head and neck. (author)

  20. Serial MRI of vestibular schwannoma presenting transient enlargement associated with intratumoral hemorrhage following radiosurgery. Two case reports

    International Nuclear Information System (INIS)

    Kikuchi, Yasuhiro; Watanabe, Kazuo; Goto, Hiromi; Isaki, Kenji; Sato, Sonomi

    2010-01-01

    Two cases of vestibular schwannoma showing transient enlargement with hemorrhage that was recognized on T2 or T2*-weighted MR image are reported. Case 1: A 72-year-old woman had a recurrent cystic lesion after resection and stereotactic radiosurgery (SRS). After retreatment by gamma knife radiosurgery, the cystic component further expanded with a fluid-fluid level, and T2 or T2*-weighted image showed markedly-low signal in the parenchymal component. Chronic hemorrhage from the cyst wall injured by irradiation is probably related to expansion of the cyst. Case 2: A 59-year-old woman received SRS. Serial MRI scans demonstrated a lesion continually expanding with homogeneous contrast enhancement on T1-weighted images. At 64 months after treatment, a central portion with high blood flow surrounded by a markedly-low intensity component of apparent hemorrhage on T2*-weighted MRI was identified. The lesion decreased in size after 73 months. Hemorrhage might occur from the neogenetic angioma-like tissue induced by irradiation effect in the tumor. Based on these observations, microvasculopathy associated with irradiation is a probable mechanism that induces bleeding in vestibular schwannoma following radiosurgery. (author)