WorldWideScience

Sample records for radionuclide ventriculography comparison

  1. Equilibrium radionuclide ventriculography: Comparison with echo-ventriculography and digital subtraction angiocardiography, evaluation of multiparameters

    Energy Technology Data Exchange (ETDEWEB)

    Hoer, G; Standke, R; Klepzig, H Jr; Maul, F D; Tuengerthal, S; Tezak, S; Reifarth, N; Kanemoto, N; Happ, J; Baum, R P

    1986-09-01

    Subsequent to the discussion of technical prerequisites (fully-automated, reproducible multiparameter-analysis (MPA), rest, exercise) which is followed by remarks concerning the pathophysiology of ischemic left ventricular functional disorders in diastole and systole, the following points are considered: 1) comparative results of RNV, cineventriculoangiography, echo-ventriculography and intraveneous digital subtraction angiocardiography; 2) 'normal' values of RNV in MPA; 3) heart and pulmonary diseases (coronary artery disease with sensitivity and specificity of MPA), chronic obstructive pulmonary disease, chronic aortic insufficiency, hypertension; 4) summary of, and prospects for future potentialities (software, clinical indications).

  2. Assessment of sistemic ventricle function in corrected transposition of great arteries with Gated SPECT: comparison with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Alexanderson, E.; Espinola, N.; Duenas, D.; Fermon, S.; Acevedo, C.; Martinez, C.

    2002-01-01

    Corrected trasposition of great arteries is a uncommon congenital heart disease where the right ventricle works as the sistemic one. QGS Gated SPECT program was designed to recognize the contours of left ventricle being a good method to evaluate left ventricle ejection fraction. The purpose of this study was to evaluate the right ventricle ejection fraction (RVEF) by gated SPECT using Tc-99mSestaMIBI in comparison with radionuclide ventriculography (RVG) in patients with corrected trasposition of great arteries. Methods: We performed gated SPECT and radionuclide ventriculography within 15 days of each other in 7 adults consecutive patients with the diagnosis of corrected trasposition of great arteries (5 men, 2 women; mean age 47 y). Gated tomographic data, including ventricular volumes and ejection fraction, were processed using QGS automatic algorithm, whereas equilibrium radionuclide ventriculography used standard techniques. Results: We found a good correlation between right ventricle ejection fraction obtained with Gated SPECT compared with equilibrium radionuclide ventriculography. The mean of the RVEF with Gated SPECT was 41.2% compared with 44.2% of RVEF with equilibrium radionuclide ventriculography. Both methods recognized abnormal RVEF in 5 patients ( 50%) with Gated SPECT and abnormal with RVG meanwhile another patient had normal RVEF with RVG and abnormal with Gated SPECT. Conclusion: Quantitative gated tomography, using Tc 99mSestaMIBI, has a good correlation with radionuclide ventriculography for the assessment of right ventricle ejection fraction in patients with corrected trasposition of great arteries. These results support the clinical use of this technique among these patients

  3. Segmental wall-motion analysis in the right anterior oblique projection: comparison of exercise equilibrium radionuclide ventriculography and exercise contrast ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Keyes, J.W. Jr.; Brymer, J.F.; Walton, J.A.; Pitt, B.

    1980-01-01

    Thirty-nine patients with known or suspected coronary artery disease were studied at rest and during supine bicycle exercise with radionuclide and contrast left ventriculography. Analysis of regional wall motion was made by visual evaluation of the five standard 30 0 right anterior oblique (RAO) wall segments in the contrast images and the corresponding 10 0 RAO radionuclide segments. The radionuclide studies were evaluated independently by three observers using a five-point grading system. The interobserver wall-motion grading agreed completely in more than 80% of segments at rest and exercise, and agreed within one wall-motion grade in more than 95% of segments. The comparison of wall-motion grades between radionuclide and contrast ventriculograms showed complete agreement in 86% of segments at rest and in 78% during exercise, and agreement within one wall-motion grade in 97% of rest and 96% of exercise segments. Visual evaluation of 10 0 RAO rest and exercise radionuclide ventriculograms compares favorably with rest and exercise 30 0 RAO contrast ventriculograms and demonstrates satisfactory interobserver agreement

  4. Improved method of static radionuclide ventriculography

    International Nuclear Information System (INIS)

    Davidzon, G.S.; Myasnik, B.N.

    1988-01-01

    A method of 2-stage recording of radionuclide ventriculography has been proposed, the second stage being shifted to a certain time interval, i.e. a delay line is introduced between a synchronizing device and computer. Particular attention is drawn to a choice of delay time depending on a computer memory volume: in a small memory volume delay time must be approximately one-third of the patient's R-R interval

  5. Radionuclide exercise ventriculography and levels of workload

    International Nuclear Information System (INIS)

    Wynchank, S.

    1982-01-01

    The wealth of useful information made available from the utilization of radionuclide cardiological investigations by non-invasive means is outlined and reasons for investigating results obtained under conditions of increased heart workload are explained. The lack of an accepted protocol for the determination of exercise levels is noted. A format for obtaining increasing heart loads dependent on increasing pulse rate is offered, with justification. Exercise radionuclide ventriculography examinations can be conducted which are simple, reproducible and allow appropriate levels of stress in patients who can benefit from such investigations

  6. Application of radionuclide ventriculography to cardiac screening

    International Nuclear Information System (INIS)

    Lindsay, J. Jr.; Milner, M.R.; Chandeysson, P.L.; Rodman, D.J.; Okin, P.M.; Goldstein, S.A.

    1989-01-01

    Screening asymptomatic individuals for latent coronary disease often requires sequential testing because exercise electrocardiography typically produces more false positive than true positive results in a population with a low prevalence of coronary disease. Cardiac scintigraphy is a technique that may be employed as a confirmatory test in lieu of coronary arteriography to further evaluate the significance of a positive exercise electrocardiogram. Radionuclide ventriculography was employed in 98 asymptomatic individuals who were considered to be at moderate risk of heart disease after risk factor analysis and exercise electrocardiography. Seventeen (17%) patients had an abnormal study and underwent cardiac catheterization. Seven had coronary artery disease, two had cardiomyopathy, and eight were normal. Eighty-one (83%) patients had a normal study. Because the sensitivity of radionuclide ventriculography is 63-80%, it was postulated that 2 to 5 individuals with disease were missed. Thus, from a population with an 11-14% prevalence of disease, two subsets were identified. A large subset in which a prevalence of 2-6% could be estimated was separated from a much smaller one in which a prevalence of approximately 50% was demonstrated

  7. Potassium cardioplegia: early assessment by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ellis, R.J.; Born, M.; Feit, T.; Ebert, P.A.

    1978-01-01

    Left ventricular function was evaluated by single pass /sup 99m/Tc radionuclide ventriculography when potassium cardioplegia was combined with hypothermia. In 35 patients undergoing myocardial revascularization (3 CABG/patient) in which potassium cardioplegia at 4 0 C was used, no patient developed a myocardial infarction either by electrocardiogram or /sup 99m/Tc pyrophosphate imaging in the postoperative period. In 22 patients, aortic cross-clamp time was greater than 60 min, and the ejection fraction by the single pass radionuclide technique was 50% preoperatively and 53% postoperatively (NS). Wall motion in the single RAO view was not worse postoperatively. No patient required any inotropic agents in the immediate postoperative period. It appears that no significant ventricular impairment occurred in the immediate postoperative period (48 to 72 hours) when potassium cardioplegia combined with hypothermia was used for a 60-minute period

  8. Assessment of ventricular function by radionuclide ventriculography in hyperthyroidism

    International Nuclear Information System (INIS)

    Dong Weiyu; He Pinyu; Zhuang Weite

    1996-01-01

    Left ventricular(LV) and right ventricular(RV) function were determined using radionuclide ventriculography in 50 patients with hyperthyroidism. LVEF, LVPFR, SV of the hyperthyroidism group were decreased in comparison with the normal group (P<0.01), whereas CO of the hyperthyroidism patients were higher than that of normal (P<0.01). Except LVPER, the LVEF, SV had significant difference between two groups. Compared to normal group, RVEF, RVPER, RVPFR were also decreased (P<0.01). Besides 30 cases of the hyperthyroidism were examined by impedance cardiogram (ICG) and impedance pulmonary rheogram (IPR), all showed closely correlation with the parameters determined by ventriculography. There was the involvement of right ventricular function insufficiency, especially in ejection phase. When compared with pre-therapy, pos-therapy cases showed significant improvement in EF, PER, PFR of left and right ventricular

  9. Comparison of exercise stress testing with dobutamine stress echocardiography and radionuclide ventriculography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Ozdemir, K.; Kisacik, H.L.; Oguzhan, A.

    1999-01-01

    Dobutamine stress echocardiography, Tc-99m radionuclide ventriculography (RNVG), and exercise stress testing were performed prospectively in 63 patients with suspected coronary artery disease to compare the values of exercise testing, dobutamine stress echocardiography and RNVG in the non-invasive diagnosis of coronary artery disease. The sensitivities of dobutamine stress echocardiography and RNVG were found to be higher than that of exercise testing (93-62%, p 0.05). There were no differences between the sensitivities of the three techniques in multiple vessel disease (p>0.05). The specificities of dobutamine stress echocardiography and RNVG were higher than that of exercise testing (for both of the tests 86-62%, p 0.05). The results of dobutamine stress echocardiography RNVG were concordant with each other in 46 patients (76%, kappa=65%) in sectional analysis. Dobutamine stress echocardiography and RNVG tests were comparable with each other in 85% of the 189 segments (kappa=64%). The expected 5% decrease at peak doses of dobutamine was not detected in stress echocardiography in 25 patients and in RNVG in 26 of the patients. Dobutamine stress echocardiography and RNVG are superior to exercise testing in the diagnosis of single vessel disease and there is no significant difference between the two techniques. When the ejection fraction is considered in dobutamine stress echocardiography and RNVG, it does not make an additional contribution to the diagnosis of coronary artery disease. (author)

  10. Factor analysis for exercise stress radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hirota, Kazuyoshi; Yasuda, Mitsutaka; Oku, Hisao; Ikuno, Yoshiyasu; Takeuchi, Kazuhide; Takeda, Tadanao; Ochi, Hironobu

    1987-01-01

    Using factor analysis, a new image processing in exercise stress radionuclide ventriculography, changes in factors associated with exercise were evaluated in 14 patients with angina pectoris or old myocardial infarction. The patients were imaged in the left anterior oblique projection, and three factor images were presented on a color coded scale. Abnormal factors (AF) were observed in 6 patients before exercise, 13 during exercise, and 4 after exercise. In 7 patients, the occurrence of AF was associated with exercise. Five of them became free from AF after exercise. Three patients showing AF before exercise had aggravation of AF during exercise. Overall, the occurrence or aggravation of AF was associated with exercise in ten (71 %) of the patients. The other three patients, however, had disappearance of AF during exercise. In the last patient, none of the AF was observed throughout the study. In view of a high incidence of AF associated with exercise, the factor analysis may have the potential in evaluating cardiac reverse from the viewpoint of left ventricular wall motion abnormality. (Namekawa, K.)

  11. Comparison between Radionuclide Ventriculography and Echocardiography for Quantification of Left Ventricular Systolic Function in Rats Exposed to Doxorubicin

    Directory of Open Access Journals (Sweden)

    Luciano Fonseca Lemos de Oliveira

    Full Text Available Abstract Background: Radionuclide ventriculography (RV is a validated method to evaluate the left ventricular systolic function (LVSF in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO in an experimental model of cardiotoxicity due to doxorubicin (DXR in rats. Methods: Adult male Wistar rats serving as controls (n = 7 or receiving DXR (n = 22 in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05. The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05; however, the LVSF values obtained by RV (60.6 ± 12.5% were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004 in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002 and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001. On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity.

  12. Comparison between radionuclide ventriculography and echocardiography for quantification of left ventricular systolic function in rats exposed to doxorubicin

    International Nuclear Information System (INIS)

    Oliveira, Luciano Fonseca Lemos de; Carvalho, Eduardo Elias Vieira de; Romano, Minna Moreira Dias; Maciel, Benedito Carlos; Simões, Marcus Vinicius

    2017-01-01

    Background: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. Methods: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity. (author)

  13. Evaluation of aortic and mitral valve regurgitation by radionuclide ventriculography: comparison with the method of Sandler and Dodge

    Energy Technology Data Exchange (ETDEWEB)

    Kress, P.; Geffers, H.; Stauch, M.; Nechwatal, W.; Sigel, H.; Bitter, F.; Adam, W.E.

    1981-01-01

    The present investigation was undertaken to introduce a quantitative scintigraphic method for evaluation of regurgitation and to compare it with the generally accepted quantitative method of Sandler and Dodge. Radionuclide ventriculography was carried out after injection of 20 mCi 99mtechnetium-labeled red blood cells. Time-activity curves were obtained from the left and right ventricular regions. The ratio of end-diastolic-end-systolic count-rate differences for the left and right ventricles was calculated. The ratio (A) was compared with a hemodynamic ratio determined after the method of Sandler and Dodge with the stroke volume of the left ventricle measured angiographically, and the stroke volume of the right ventricle measured by thermodilution. In 33 patients with aortic and mitral valve regurgitation researchers found a correlation of r . 0.75. Due to a broad range of normal values of the sensitivity of the scintigraphic method is low. The specificity seems to be high, however, since in 64 patients with all types of heart diseases there were no false positive results. Comparing the described scintigraphic method with other modern or generally accepted methods, the principal advantages are noninvasiveness, good practicability, and the fact that important additional information about the functional state of the heart is gained. This is important in follow-up studies in patients with chronic valvular incompetence. It seems that this method will become a valuable supplement to heart catheterization in the diagnosis of valvular heart disease and may partially replace invasive methods for measuring the regurgitation fraction.

  14. Evaluation of aortic and mitral valve regurgitation by radionuclide ventriculography: comparison with the method of Sandler and Dodge

    International Nuclear Information System (INIS)

    Kress, P.; Geffers, H.; Stauch, M.; Nechwatal, W.; Sigel, H.; Bitter, F.; Adam, W.E.

    1981-01-01

    The present investigation was undertaken to introduce a quantitative scintigraphic method for evaluation of regurgitation and to compare it with the generally accepted quantitative method of Sandler and Dodge. Radionuclide ventriculography was carried out after injection of 20 mCi 99mtechnetium-labeled red blood cells. Time-activity curves were obtained from the left and right ventricular regions. The ratio of end-diastolic-end-systolic count-rate differences for the left and right ventricles was calculated. The ratio (A) was compared with a hemodynamic ratio determined after the method of Sandler and Dodge with the stroke volume of the left ventricle measured angiographically, and the stroke volume of the right ventricle measured by thermodilution. In 33 patients with aortic and mitral valve regurgitation researchers found a correlation of r . 0.75. Due to a broad range of normal values of the sensitivity of the scintigraphic method is low. The specificity seems to be high, however, since in 64 patients with all types of heart diseases there were no false positive results. Comparing the described scintigraphic method with other modern or generally accepted methods, the principal advantages are noninvasiveness, good practicability, and the fact that important additional information about the functional state of the heart is gained. This is important in follow-up studies in patients with chronic valvular incompetence. It seems that this method will become a valuable supplement to heart catheterization in the diagnosis of valvular heart disease and may partially replace invasive methods for measuring the regurgitation fraction

  15. Comparison between radionuclide ventriculography and echocardiography for quantification of left ventricular systolic function in rats exposed to doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de; Carvalho, Eduardo Elias Vieira de; Romano, Minna Moreira Dias; Maciel, Benedito Carlos; Simões, Marcus Vinicius, E-mail: msimoes@fmrp.usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Centro de Cardiologia; O' Connell, João Lucas; Pulici, Érica Carolina Campos [Universidade Federal de Uberlândia (UFU), MG (Brazil)

    2017-01-15

    Background: Radionuclide ventriculography (RV) is a validated method to evaluate the left ventricular systolic function (LVSF) in small rodents. However, no prior study has compared the results of RV with those obtained by other imaging methods in this context. Objectives: To compare the results of LVSF obtained by RV and echocardiography (ECHO) in an experimental model of cardiotoxicity due to doxorubicin (DXR) in rats. Methods: Adult male Wistar rats serving as controls (n = 7) or receiving DXR (n = 22) in accumulated doses of 8, 12, and 16 mg/kg were evaluated with ECHO performed with a Sonos 5500 Philips equipment (12-MHz transducer) and RV obtained with an Orbiter-Siemens gamma camera using a pinhole collimator with a 4-mm aperture. Histopathological quantification of myocardial fibrosis was performed after euthanasia. Results: The control animals showed comparable results in the LVSF analysis obtained with ECHO and RV (83.5 ± 5% and 82.8 ± 2.8%, respectively, p > 0.05). The animals that received DXR presented lower LVSF values when compared with controls (p < 0.05); however, the LVSF values obtained by RV (60.6 ± 12.5%) were lower than those obtained by ECHO (71.8 ± 10.1%, p = 0.0004) in this group. An analysis of the correlation between the LVSF and myocardial fibrosis showed a moderate correlation when the LVSF was assessed by ECHO (r = -0.69, p = 0.0002) and a stronger correlation when it was assessed by RV (r = -0.79, p < 0.0001). On multiple regression analysis, only RV correlated independently with myocardial fibrosis. Conclusion: RV is an alternative method to assess the left ventricular function in small rodents in vivo. When compared with ECHO, RV showed a better correlation with the degree of myocardial injury in a model of DXR-induced cardiotoxicity. (author)

  16. Comparison of two-dimensional echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction

    International Nuclear Information System (INIS)

    Van Reet, R.E.; Quinones, M.A.; Poliner, L.R.; Nelson, J.G.; Waggoner, A.D.; Kanon, D.; Lubetkin, S.J.; Pratt, C.M.; Winters, W.L. Jr.

    1984-01-01

    Two-dimensional echocardiography and gated radionuclide ventriculography were performed in 93 patients (66 men, 27 women; mean age 61 years) with 95 episodes of acute myocardial infarction within 48 hours and at 10 days after infarction. Abnormal motion of an inferior or posterior wall segment was seen in 91% of inferoposterior infarctions by echocardiography versus 61% seen by radionuclide ventriculography. Ejection fractions determined by echocardiography and radionuclide ventriculography correlated well (r . 0.82) and did not change from the first 48 hours to 10 days after infarction (0.48 +/- 0.14). Similarly, wall motion score showed minimal change from the first 48 hours to 10 days. In-hospital mortality was 37 and 42% in patients with an ejection fraction of 0.35 or less by echocardiography and radionuclide ventriculography, respectively. No mortality was seen in patients with an ejection fraction above 0.40 by either test. The echocardiographic wall motion score was also predictive of mortality (40 versus 2%; score less than or equal to 0.50 versus greater than 0.50). The 1 year mortality rate in the 81 short-term survivors was 17%. Mortality was lowest in patients with an ejection fraction above 0.49 or wall motion score above (0.79 (2 to 5%) and worse in those with an ejection fraction below 0.36 or wall motion score below 0.51 (36 to 63%) by either technique. Thus in acute myocardial infarction, echocardiography and radionuclide ventriculography provide a comparable assessment of left ventricular function and wall motion in anterior infarction. Echocardiography appears more sensitive in detecting inferoposterior wall motion abnormalities. Both techniques are capable of identifying subgroups of patients with a high risk of death during the acute event and with an equally high mortality rate over a 1 year follow-up period

  17. Pharmacological radionuclide ventriculography for detection of myocardial contractile reserve in patients after myocardial infarction: head-to-head comparison of low dose dobutamine and low dose dypiridamole

    International Nuclear Information System (INIS)

    Petrasinovic, Z.; Ostojic, M.; Beleslin, B.; Stojkovic, S.; Nedeljkovic, M.; Stankovic, G.; Dikic, A.; Pavlovic, S.; Sobic, D.

    2002-01-01

    Background. Low dose pharmacological stress echocardiography with either dobutamine or dipyridamole infusion has been proposed for recognition of myocardial viability. However, dependence on adequate acoustic window, observer experience, and the mild degree of wall motion changes make the viability assessment by stress echocardiography especially bothersome. The objective of the study was to evaluate the ability of low dose dobutamine and low dose dipyridamole radionuclide ventriculography to detect contractile reserve in patients after myocardial infarction and functional recovery after coronary angioplasty. Methods. The study group consisted of 20 consecutive patients (52±10 years, 17 male) with previous myocardial infarction and resting regional dyssynergy, in whom diagnostic cardiac catheterization revealed significant one-vessel coronary artery stenosis suitable for angioplasty. Each patient underwent equilibrium 99m-Tc radionuclide ventriculography which was performed at rest and during low dose dipyridamole (0.28 mg/kg over 2 minutes) and low dose dobutamine infusion (up to 10 mcg/kg/min). Left ventricular global and regional ejection fractions were determined. Increase of regional ejection fraction for >5% (inferoapical and posterolateral regions) or >10% (anteroseptal regions) during low dose dobutamine and dipyridamole in infarcted regions, as well as in the follow up period, was considered as index of contractile reserve. After 8 weeks of successful angioplasty, resting radionuclide ventriculography was repeated in all patients in order to identify functional recovery of the infarct zone. Results. Out of the 180 analyzed segments (20x9), 90 regional ejection fractions have shown depressed contractility. The mean of the regional ejection fractions showing depressed contractility increased from the resting value of 34±12% to 42±14% in the follow-up period (p=0.06). Of the 90 with baseline dyssynergy, 46 were responders during low-dose dobutamine (51

  18. Results of radionuclide ventriculography in normal children and adolescents

    International Nuclear Information System (INIS)

    Reich, O.; Krejcir, M.; Ruth, C.

    1989-01-01

    In order to assess the range of normal values in radionuclide ventriculography, 53 normal children and adolescents were selected in retrospect. All were exdamined by radionuclide angiocardiography on account of clinical and echocardiographical suspicion of congenital heart disease with a left-to-right shunt; a significant shunt was, however, excluded. In all patients, after equilibration of the radiopharmaceutical the ventricular function was examined by radionuclide ventriculography. The usual volume, time and rate characteristics were evaluated. The normal range was defined as the mean ±2 standard deviations which is 47 to 72% for the ejection fraction of the left ventricle and 31 to 56% for the ejection fraction of the right ventricle. (author). 2 tabs., 18 refs

  19. Radionuclide ventriculography in children with Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Tian Jiahe

    1992-01-01

    The ventricular functions of 22 children with Duchenne disease(DD) were studied by radionuclide multi-gated ventriculography using in-vivo labeled 99m Tc-RBC and compared with those of 30 age-matched normal children, 20 congenital heart disease and 7 congestive cardiomyopathy. 21 parameters were evaluated, including RV and LV EF, systolic and diastolic functions and phase distribution, etc. It was found that the DD patients showed several specific cardiac functional alterations, i.e, slight but significant abnormality in both systolic and diastolic function, special phase delay at post-lateral segment of LV in 81.8% of the patients. It is concluded that (1) all DD patients have definite evidence of heart injury; (2) the injury is mainly on the left side of the heart, influencing entire cardiac cycle; (3) there is specific phase abnormality in DD patients; (4) the radionuclide ventriculography is of great value in monitoring of these cardiac functional changes

  20. Quantitative assessment of valvular regurgitation using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Shi Rongfang

    1992-01-01

    Radionuclide ventriculography has been used to assess quantitatively the extent of mitral and aortic regurgitation in 70 patients and compared to echocardiography and the finding of surgery. Two radionuclide parameters were measured: regurgitant index (RI) = left ventricular stroke counts/right ventricular stroke counts; and regurgitant fraction (RF) = left ventricular stroke counts-right ventricular stroke counts/left ventricular stroke counts. In 28 patients without valvular heart disease, the RI was 1.10 ± 0.15 and Rf was 10.3 ± 15.0%, respectively. However, in patients with valvular regurgitation, the RI and RF were 3.41 ± 1.73 and 61.1 ± 21.2%, respectively. A good correlation was found between the results obtained by radionuclide techniques and the findings of surgery and doppler studies. The level of concordance between RI and surgical findings was 91.7%. Follow up studies in 10 patients after valvular replacement surgery showed the RI and RF return to normal. These data suggested that radionuclide ventriculography is very useful for quantitative assessment of valvular regurgitation

  1. Equilibrium radionuclide ventriculography in male patients after transmural myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Nestaval, A; Stanek, V; Malek, I; Kidery, J; Runczik, I [Institut pro Klinickou a Experimentalni Medicinu, Prague (Czechoslovakia); Cernoch, V; Oppelt, A [Institut pro Dalsi Vzdelavani Lekaru a Farmaceutu, Prague (Czechoslovakia)

    1982-12-17

    The ejection fraction of the left ventricle was measured using the method of equilibrium radionuclide ventriculography in 10 healthy males and 57 males after the first transmural myocardial infarction. The examination was effected 4 to 7 months after the event and the sample is representative for males after myocardial infarction who are younger than 65 years and show no signs of heart insufficiency by the time of examination. The resting value of the ejection fraction was 63+-5% in healthy males, 54+-7% in patients with uncomplicated myocardial infarction and 37+-8% in patients with clinical manifestations of heart insufficiency in acute phase. The differences between the groups are statistically significant. In patients with anteroseptal localization of myocardial infarction there was a negative correlation between the ejection fraction on the one hand and the sum of the voltages of Q waves in precordial ECG map and the maximum value of serum creatine kinase in acute phase on the other. The ejection fraction was in correlation to the degree of pulmonary hypertension measured in equal phase during exercise. The ejection fraction was measured in 31 patients under the working load of 50 W; significant changes were not found in healthy males or in patients after myocardial infarction. No changes were found when the state just before discharge from the hospital was compared with his state 6 months after myocardial infarction. The results obtained in compensated patients showed a relative stability of the value of the ejection fraction both during the first 6 months after discharge and under a mild working load. A comparison between the indicators in acute phase and hemodynamic examination after 6 months shows that the value of the ejection fraction is a sensitive indicator of the extent of necrosis and functional lesion of the left ventricle.

  2. Preoperative prediction of reversible myocardial asynergy by postexercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Rozanski, A.; Berman, D.; Gray, R.; Diamond, G.; Raymond, M.; Prause, J.; Maddahi, J.; Swan, H.J.; Matloff, J.

    1982-01-01

    Myocardial asynergy is sometimes reversed by coronary bypass, and a noninvasive method of predicting which assess are reversible would be desirable. To assess whether changes in myocardial wall motion observed immediately after exercise can differentiate reversible from nonreversible myocardial asynergy, we evaluated 53 patients by radionuclide ventriculography before and after exercise and again at rest after coronary bypass surgery. Preoperative improvement in wall motion immediately after exercise was highly predictive of the surgical outcome (average chance-corrected agreement, 91 per cent). At surgery the asynergic segments that had improved after exercise were free of grossly apparent epicardial scarring. The accuracy of these predictions for postoperative improvement was significantly greater (P less than 0.01) than that of analysis of Q waves on resting electrocardiography (average chance-corrected agreement, 40 per cent). In contrast, preoperative changes in left ventricular ejection fraction after exercise were not predictive of postoperative resting ejection fraction. We conclude that postexercise radionuclide ventriculography can be used to identify reversible resting myocardial asynergy. This test should prove effective in predicting which patients with myocardial asynergy are most likely to benefit from aortocoronary revascularization

  3. Comparison of exercise ECG and radionuclide ventriculography in the assessment of myocardial ischemia in patients with isolated stenoses of the left anterior descending artery

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Mildenberger, D.; Kaltenbach, M.; Standke, R.; Baum, R.P.; Tezak, S.; Maul, F.D.; Hoer, G.

    1988-01-01

    21 patients with LAD-stenoses of at least 70% and 21 patients with LAD-stenoses and additional intramural anterior wall infarctions were studied. 20 patients without heart disease or after successful transluminal coronary angioplasty and 18 patients with intramural anterior wall infarction after successful transluminal dilatation of the LAD (remaining stenosis maximal 30%) served as controls. The normal range of global and regional left ventricular ejection fraction response to exercise was defined based on the data of 25 further patients without relevant coronary heart disease. Thus, a decrease in global ejection fraction and regional wall motion abnormalities were judged pathological. All patients were comparable with respect to age, ejection fraction at rest and work load. Myocardial ischemia could be detected by the exercise ECG in 81% of all patients without infarction and in 71% of patients with infarction. The corresponding values for global left ventricular ejection fraction were 76% and 81%, respectively, and for regional ejection fraction 95% in both groups. No false-positive exercise ECGs were observed in the healthy controls and 2(11%) in the corresponding group with intramural infaction. The global ejection fraction was pathological in 1(5%) healthy subject without infarction and in 3(17%) corresponding patients with infarction. Sectorial analysis revealed 5 and 22%, respectively. Our findings suggest that the exercise ECG has a limited sensitivity to detect myocardial ischemia in patients with isolated LAD-stenoses and intramural myocardial infarction. Radionuclide ventriculography yields pathological values more often; however, false-positive results also occur more frequently. (orig.) [de

  4. Detection of coronary artery disease by exercise radionuclide ventriculography, (1)

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Saito, Muneyasu; Uehara, Toshiisa; Kozuka, Takahiro

    1982-01-01

    In order to assess the detection of coronary artery disease (CAD) and LV functional reserve, exercise radionuclide ventriculography (ERV) were performed in 80 patients who underwent selective cardiac catneterization for evaluation of chest pain syndrome. 70 patients had CAD (30 patients with angina pectoris and 40 patients with myocardial infarction) and 10 did not. In this study, to obtain accurate data by ERV, its practical consideration were metioned. Radionuclide cardioangiography with sup(99m)Tc-invivo RBC labelling were performed using an Anger camera attached with high-sense collimator and on-line minicomputer system. For data aquisition, multi-gated method were used, especially during exercise, list mode collection was suitable for ERV because of variable R-R intervals. Patient stability was performed with an adjustable shoulder support and hand grip, ECG monitoring system by carbon electrolode was used to obtain during exercise. Exercise protocal was graded bicycle ergometer in supine position. As the results, in the patients of CAD, changes of LVEF from rest to exercise were under 5%, while in normal patients, LVEF increased over 5% in all patients. In 30 patients with angina pectoris, the ERV was abnormal in 25 for a sensitivity of 83.3% and specificity of 100%. The ERV were thought to be superior than stress ECG for the detection of CAD. In conclusion, with increasing clinical application, the use of ERV is rapidly becoming wider-spread but the excellent results were thought to depend upon the careful attention to equipment and exercise procedure. (author)

  5. Radionuclide ventriculography for evaluation of left ventricular function in patients after myocardial infarction

    International Nuclear Information System (INIS)

    Sledzevskaya, I.K.; Stroganova, N.P.; Il'yash, M.G.

    1989-01-01

    The use of an expanded set of parameters of radionuclide ventriculography with 99m Tc-prtechnetate, characterizing myocardial function, made it possible to specify radionuclide semiotics of myocardial infarction, to identify 4 cardiodynamic types, and to establish correlation between a degree of cardiodynamic changes and a site of lesion, and the relationship with exercise tolerance

  6. Exercise radionuclide ventriculography to detect restenosis following coronary angioplasty

    International Nuclear Information System (INIS)

    De Puey, E.G.; Leatherman, L.L.; Dear, W.E.; Leachman, R.D.; Massin, E.K.; Mathur, V.S.; Burdine, J.A.

    1984-01-01

    Forty one patients (pts) underwent semiupright exercise gated radionuclide ventriculography (EGRNV) before, within 3 d after single vessel transluminal coronary angioplasty (TCA), and 4 to 12 mos later, at which time follow-up cardiac catheterization was also performed. Prior to TCA 76% of pts had abnormal EGRNV, as defined by a failure to increase ejection fraction (EF) by 5 points or the development of a new regional wall motion abnormality. Stenosis was reduced from 90 +- 7% to 18 +- 17%. Early after TCA, exercise duration and maximum double product increased (p's 20% but <50%; Group III (n=8): ≥ 50%] Pts with abnormal EGRNV early after TCA were demonstrated to have a greater percent increase in stenosis at late follow-up than pts with normal EGRNV (41 +- 30% vs 19 +- 25%, p<.001). Early after TCA EGRNV was abnormal in 5% of Group I pts vs 75% in Group III (p<.01), and EF increased to a greater degree during exercise in Group I pts (+11.3 +- 7.5 vs +3.5 +- 6.5 points, p<.01). At 4-12 mos EGRNV was abnormal in 27% of Group I vs 88% of Group III (p<.01), and during exercise EF increased in Group I pts (+11.8 +- 7.8 points) but decreased in Group III (-1.9 +- 8.7 points) (p<.0005). The accuracy of abnormal EGRNV in predicting ≥ 50% restenosis was 73% early post-TCA and 77% at 4-12 mos. The authors conclude that EGRNV is a valuable test to verify the success of TCA and to detect subsequent restenosis

  7. Receiver operating characteristic analysis improves diagnosis by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Dickinson, C.Z.; Forman, M.B.; Vaugh, W.K.; Sandler, M.P.; Kronenberg, M.W.

    1985-01-01

    Receiver operating characteristic analysis (ROC) evaluates continuous variables to define diagnostic criteria for the optimal sensitivity (SENS) and specificity (SPEC) of a test. The authors studied exercise-induced chest pain (CP), ST-changes on electrocardiography (ECG) and rest-exercise gated radionuclide ventriculography (RVG) using ROC to clarify the optimal criteria for detecting myocardial ischemia due to coronary artherosclerosis (CAD). The data of 95 consecutive patients studied with coronary angiography, rest-exercise RVG and ECG were reviewed. 77 patients had ''significant'' CAD (≥50% lesions). Exercise-induced CP, ECG abnormalities (ST-T shifts) and RVG abnormalities (change in ejection fraction, 2-view regional wall motion change and relative end-systolic volume) were evaluated to define optimal SENS/SPEC of each and for the combined data. ROC curves were constructed by multiple logistic regression (MLR). By MLR, RVG alone was superior to ECG and CP. The combination of all three produced the best ROC curve for the entire group and for clinical subsets based on the number of diseased vessels and the presence or absence of prior myocardial infarction. When CP, ECG and RVG were combined, the optimal SENS/SPEC for detection of single vessel disease was 88/86. The SENS/SPEC for 3 vessel disease was 93/95. Thus, the application of RVG for the diagnosis of myocardial ischemia is improved with the inclusion of ECG and CP data by the use of a multiple logistic regression model. ROC analysis allows clinical application of multiple data for diagnosing CAD at desired SENS/SPEC rather than by arbitrary single-standard criteria

  8. Prognostic value of echocardiography in 190 patients with chronic congestive heart failure. A comparison with New York Heart Association functional classes and radionuclide ventriculography

    DEFF Research Database (Denmark)

    Madsen, B K; Videbaek, R; Stokholm, H

    1996-01-01

    Survival in 190 consecutive patients with congestive heart failure, discharged from a general hospital, was studied. Sixteen patients were in New York Heart Association (NYHA) class I, 87 in II, 83 in III and 4 in IV. Median left ventricular ejection fraction (LVEF) from radionuclide...

  9. Evaluation of segmental left ventricular wall motion by equilibrium gated radionuclide ventriculography.

    Science.gov (United States)

    Van Nostrand, D; Janowitz, W R; Holmes, D R; Cohen, H A

    1979-01-01

    The ability of equilibrium gated radionuclide ventriculography to detect segmental left ventricular (LV) wall motion abnormalities was determined in 26 patients undergoing cardiac catheterization. Multiple gated studies obtained in 30 degrees right anterior oblique and 45 degrees left anterior oblique projections, played back in a movie format, were compared to the corresponding LV ventriculograms. The LV wall in the two projections was divided into eight segments. Each segment was graded as normal, hypokinetic, akinetic, dyskinetic, or indeterminate. Thirteen percent of the segments in the gated images were indeterminate; 24 out of 27 of these were proximal or distal inferior wall segments. There was exact agreement in 86% of the remaining segments. The sensitivity of the radionuclide technique for detecting normal versus any abnormal wall motion was 71%, with a specificity of 99%. Equilibrium gated ventriculography is an excellent noninvasive technique for evaluating segmental LV wall motion. It is least reliable in assessing the proximal inferior wall and interventricular septum.

  10. Intravenous streptokinase therapy in acute myocardial infarction: Assessment of therapy effects by quantitative 201Tl myocardial imaging (including SPECT) and radionuclide ventriculography

    International Nuclear Information System (INIS)

    Koehn, H.; Bialonczyk, C.; Mostbeck, A.; Frohner, K.; Unger, G.; Steinbach, K.

    1984-01-01

    To evaluate a potential beneficial effect of systemic streptokinase therapy in acute myocardial infarction, 36 patients treated with streptokinase intravenously were assessed by radionuclide ventriculography and quantitative 201 Tl myocardial imaging (including SPECT) in comparison with 18 conventionally treated patients. Patients after thrombolysis had significantly higher EF, PFR, and PER as well as fewer wall motion abnormalities compared with controls. These differences were also observed in the subset of patients with anterior wall infarction (AMI), but not in patients with inferior wall infarction (IMI). Quantitative 201 Tl imaging demonstrated significantly smaller percent myocardial defects and fewer pathological stress segments in patients with thrombolysis compared with controls. The same differences were also found in both AMI and IMI patients. Our data suggest a favorable effect of intravenous streptokinase on recovery of left ventricular function and myocardial salvage. Radionuclide ventriculography and quantitative 201 Tl myocardial imaging seem to be reliable tools for objective assessment of therapy effects. (orig.)

  11. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references.

  12. Rest and exercise radionuclide ventriculography in the ambulatory monitoring of patients with valvular heart disease

    International Nuclear Information System (INIS)

    Raichlen, J.S.; Brest, A.N.

    1988-01-01

    Radionuclide angiography serves as a valuable adjunct in the noninvasive evaluation and monitoring of patients with valvular heart disease. Although estimations of regurgitant fractions and the differences between left and right ventricular stroke volumes can be made, the limitations of the techniques do not enable adequate quantitation of the severity of valvular insufficiency to warrant routine use in ambulatory management. The importance of radionuclide ventriculography, however, lies in its ability to examine global ventricular function both at rest and with exercise, thus enabling assessment of the functional reserve of the left and right ventricles. Such data are of considerable value in determining the need for invasive evaluation and the timing of valve replacement in patients with valvular heart disease. 41 references

  13. Importance of adequate exercise in the detection of coronary heart disease by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Lo, K.; Pitt, B.

    1980-01-01

    Rest and exercise radionuclide ventriculograms were obtained on 77 symptomatic patients without prior documented coronary artery disease (CAD). Coronary artery disease was present by angiograms in 48. Radionuclide ventriculography (RNV) was abnormal in 41 patients (overall sensitivity 85%). In 29 patients with normal coronary arteries, RNV was normal in 24 (specificity 83%). To determine if the exercise level affects sensitivity, the studies were graded for adequacy of exercise. It was considered adequate if patients developed (a) chest pain, or (b) ST segment depression of at least 1 mm, or (c) if they achieved a pressure rate product greater than 250. Among the 48 patients with coronary artery disease, 35 achieved adequate exercise. Thirty-three had an abnormal RNV (sensitivity 94%). In 13 patients who failed to achieve adequate exercise, RNV was abnormal in eight (sensitivity of only 62%). Some patients with coronary artery disease may have a normal ventricular response at inadequate levels of stress

  14. Normal left ventricular emptying in coronary artery disease at rest: analysis by radiographic and equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    Denenberg, B.S.; Makler, P.T.; Bove, A.A.; Spann, J.F.

    1981-01-01

    The volume ejected early in systole has been proposed as an indicator of abnormal left ventricular function that is present at rest in patients with coronary artery disease with a normal ejection fraction and normal wall motion. The volume ejected in systole was examined by calculating the percent change in ventricular volume using both computer-assisted analysis of biplane radiographic ventriculograms at 60 frames/s and equilibrium gated radionuclide ventriculograms. Ventricular emptying was examined with radiographic ventriculography in 33 normal patients and 23 patients with coronary artery disease and normal ejection fraction. Eight normal subjects and six patients with coronary artery disease had both radiographic ventriculography and equilibrium gated radionuclide ventriculography. In all patients, there was excellent correlation between the radiographic and radionuclide ventricular emptying curves (r . 0.971). There were no difference in the ventricular emptying curves of normal subjects and patients with coronary artery disease whether volumes were measured by radiographic or equilibrium gated radionuclide ventriculography. It is concluded that the resting ventricular emptying curves are identical in normal subjects and patients with coronary artery disease who have a normal ejection fraction and normal wall motion

  15. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Csernay, L.; Mester, J.; Edes, I.; Pavics, L.; Gruber, N.; Szasz, K.; Csanady, M.

    1985-08-04

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed

  16. Possibilities of exercise radionuclide ventriculography carried out in equilibrium in the detection of ischaemic heart disease

    International Nuclear Information System (INIS)

    Csernay, Laszlo; Mester, Janos; Edes, Istvan; Pavics, Laszlo; Gruber, Noemi; Szasz, Karoly; Csanady, Miklos

    1985-01-01

    Authors give account of the initiation of the exercise radionuclide ventriculography and of their diagnostic experiences. In 33 control persons and 20 patients with coronary heart disease verified with coronarography, the left ventricular ejection fraction, the wall motion and the systolic and diastolic volume of the left ventricle were examined at rest and during exercise. A decrease or an increase of not more than 5% of ejection fraction, the exercise induced wall motion abnormalities or an increase of resting wall motion disorder were interpreted as an index of underlying significant coronary stenosis. A sensitivity of 90% and a specificity of 88% of the method were found. Upon the results, which are in good agreement with literary data, the initiation of the method in nuclear medical laboratories equipped with camera-computer system is proposed. (author)

  17. Analysis of cardiac images of radionuclide ventriculography in AT-Type personal computer

    International Nuclear Information System (INIS)

    Lillo, R.; Gonzalez, P.; Ehijo, A.; Otarola, T.M.S.; Ortiz, M.; Silva, A.M.; Ortiz, M.

    1990-01-01

    The goal of this research was to produce software for the processing of Cardiac Phase images in personal computers. The results of standard radionuclide Ventriculography and Fourier analysis, got on gamma camera Ohio Nuclear 410 Sygma and Digital PDP 11/34 computer were coded into ASCII file and then transfered via Smarterm 220/Kermit to an Accel 900 AT PC. After decoding the images they were processed with a program develope in C Lenguaje obtaining the values of Phase Angles in the whole phase images and in regions of interest drawn around the cardiac chambers. The images and values were the same as those obtained by conventional processing in the PDP 11/34 computer. This is considered a first stage for the use of PC to Nuclear Medicine imaging studies. (author)

  18. Relative value of clinical variables, bicycle ergometry, rest radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring at discharge to predict 1 year survival after myocardial infarction

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); R.W. Brower (Ronald); M.L. Simoons (Maarten); H.J. ten Katen (Harald); A. Beelen (Anita); T. Baardman (Taco); J. Lubsen (Jacob); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractThe relative value of predischarge clinical variables, bicycle ergometry, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring for predicting survival during the first year in 351 hospital survivors of acute myocardial infarction was assessed. Discriminant

  19. Problems in clinical assessment of left ventricular peak filling rate with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Kim, Bong-Ha; Tsuneoka, Yutaka

    1987-02-01

    With an increased clinical application of early peak diastolic filling rate (PFR) using radionuclide ventriculography, problems of its clinical significance have emerged. The study was designed to answer the following questions: 1) accuracy of PFR measurement, 2) normalization of PFR, and 3) whether PFR may reflect left ventricular relaxation rate (LVRR). In measuring PFR, an elevated framing rate was required, and the optimal rate was 20 msec/F. Second sound heart gating technique proved to be complementary to conventional ECG R wave gating technique in the evaluation of left ventricular diastolic volume curves and mean filling rate associated with changes in the range of R-R interval. PFR which was normalized with end-diastolic volume (EDV) did not necessarily reflect measured PFR because of individual differences of EDV. An experiment on the relationship of mitral valve pressure to blood flow in dogs revealed that PFR was influenced by not only LVRR but also left atrial pressure. These results may raise a question of the rationale for using the measurement of PFR, as well as its technical problems, in the objective evaluation of LVRR. (Namekawa, K.).

  20. Effects of AV delay programming on ventricular resynchronisation: role of radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Siegrist, Patrick T.; Comte, Nathalie; Holzmeister, Johannes; Suetsch, Gabor; Koepfli, Pascal; Namdar, Mehdi; Duru, Firat; Brunckhorst, Corinna; Scharf, Christoph [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [Universitiy Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology, Zurich (Switzerland)

    2008-08-15

    Optimal atrioventricular delay (AVD) setting for cardiac resynchronisation therapy, i.e. biventricular pacing in patients with heart failure, remains a formidable challenge. Thus, the purpose of this study was to evaluate the effects of different AVD on inter- and intra-ventricular resynchronisation using phase histograms of radionuclide ventriculography (RNV). In 17 consecutive patients (mean age 64 {+-} 6 years), RNV was performed 236 {+-} 350 days after pacemaker implantation for cardiac resynchronisation therapy. Images were acquired during atrial pacing at 80 bpm and during biventricular pacing with AVD ranging from 80 to 160 ms. Inter-ventricular dyssynchrony was measured by the delay between the mean phase angles of the left and right ventricles. Intra-ventricular dyssynchrony was measured by the standard deviation (SD) of left ventricular phase histograms. Left ventricular (LV) ejection fraction (EF) was inversely correlated to LV dyssynchrony (SD of LV phase histogram, R = -0.82, p < 0.0001). However, the increase in LVEF by biventricular pacing (mean +4.4 {+-} 4%) showed only modest correlation to the resulting resynchronisation effect (characterised by a -13 {+-} 8 decrease in LV phase histogram SD, R = -0.38, p < 0.0001). RNV is helpful in optimising pacing parameters for resynchronisation therapy. Varying AVD did not have a major impact on intra- or inter-ventricular resynchronisation. Thus, the benefit of AVD-based LVEF optimisation seems to result from atrioventricular resynchronisation. (orig.)

  1. Left ventricle expands maximally preceding end-diastole. Radionuclide ventriculography study

    International Nuclear Information System (INIS)

    Horinouchi, Osamu

    2002-01-01

    It has been considered that left ventricle (LV) expands maximally at the end-diastole. However, is it exactly coincident with this point? This study was aimed to determine whether the maximal expansion of LV coincides with the peak of R wave on electrocardiogram. Thirty-three angina pectoris patients with normal LV motion were examined using radionuclide ventriculography. Data were obtained from every 30 ms backward frame from the peak of R wave. All patients showed the time of maximal expansion preceded the peak of R wave. The intervals from the peak of R wave and the onset of P wave to maximal expansion of LV was 105±29 ms and 88±25 ms, respectively. This period corresponds to the timing of maximal excurtion of mitral valve by atrial contraction, and the centripetal motion of LV without losing its volume before end-diastole may be interpreted on account of the movement of mitral valve toward closure. These findings suggest that LV expands maximally between P and R wave after atrial contraction, preceding the peak of R wave thought conventionally as the end-diastole. (author)

  2. Clinical assessment of first pass radionuclide ventriculography after dipyridamole infusion in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Kanaya, Tohru; Tono-oka, Ichiro; Satoh, Satoshi; Yamaguchi, Yoshiko; Hoshi, Hikaru; Ikeda, Kozue; Tsuiki, Kai; Yasui, Shoji; Komatani, Akio

    1986-01-01

    First pass radionuclide ventriculography (RNV) was performed after dipyridamole (D) infusion in 33 patients with coronary artery disease (CAD) and 15 normal volunteers. RNV findings after D infusion were compared with those of conventional exercise RNV and body surface ECG mapping (MAP). For patients with multiple vessel disease, left ventricular ejection fraction (LVEF) was significantly lower after D infusion than at rest. Wall motion abnormality (WMA) sites induced by D infusion were well coincident with those induced by exercise. Pressure rate product at exercise was significantly higher than that after D infusion, suggesting the different mechanism of the occurrence of WMA after D infusion and at exercise. The incidence of ischemic reaction tended to be higher after D infusion than at exercise in 25 patients with CAD. There was negative correlation between ST depression on MAP after D infusion and LVEF on RNV after D infusion. This RNV after D infusion can be used as a supplement tool to conventional exercise RNV in the evaluation of the degree of coronary artery lesions and preserved left ventricular function. (Namekawa, K.)

  3. Automated system for ST segment and arrhythmia analysis in exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hsia, P.W.; Jenkins, J.M.; Shimoni, Y.; Gage, K.P.; Santinga, J.T.; Pitt, B.

    1986-01-01

    A computer-based system for interpretation of the electrocardiogram (ECG) in the diagnosis of arrhythmia and ST segment abnormality in an exercise system is presented. The system was designed for inclusion in a gamma camera so the ECG diagnosis could be combined with the diagnostic capability of radionuclide ventriculography. Digitized data are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is provided. Each beat is assigned a beat code based on a combination of waveform analysis and RR interval measurement. The waveform analysis employs a new correlation coefficient formula which corrects for baseline wander. Selective signal averaging, in which only normal beats are included, is done for an improved signal-to-noise ratio prior to ST segment analysis. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate have all been automated. ST level and slope measurements are computed on signal-averaged data. Arrhythmia analysis of 13 passages of abnormal rhythm by computer was found to be correct in 98.4 percent of all beats. 25 passages of exercise data, 1-5 min in length, were evaluated by the cardiologist and found to be in agreement in 95.8 percent in measurements of ST level and 91.7 percent in measurements of ST slope

  4. Effect of acute postinfusion lipemia and free fatty acids on myocardial contractility: Assessment with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, L; Freeman, M L; Barnes, W E; Kaplan, E; Pacold, I; Loeb, H S; Johnson, B; Reid, R W

    1986-08-01

    Equilibrium gated radionuclide ventriculography was used to valuate the effect of intravenous fat-emulsion overload and excess of free fatty acids (FFA) on left ventricular ejection fraction (LVEF) in 20 patients with and without coronary artery disease (CAD). Fifteen of these patients had normal (>50%) baseline LVEF and 5 had low (<50%) baseline LVEF. From 100 to 150 ml of 20% artificial fat emulsion (Liposyn) was infused over 20-25 min. At the end of the infusion, triglyceridemia reached 820 +- 220 mg% and left ventricular ejection fraction decreased from baseline 62 +- 19% (mean +-SD) to 58 +- 16% (P < 0.05, paired t-test). After completion of Liposyn infusion, 5,000 U of heparin was administered intravenously and monitoring of LVEF was continued. One and one-half hours following heparin administration, plasma FFA levels reached 3.7 + 2.0 mmol/l and LVEF rose to 69 +- 19% (P < 0.001, paired t-test). Our data indicate that acute intravenous fat overload can suppress and high pathophysiologic levels of FFA can increase LVEF. This effect is more uniform and statistically more reliable in patients with normal LVEF. The study failed to demonstrate any significant difference in the effect of this pharmacologic intervention between patients with and without CAD.

  5. Clinical validation of the planar radionuclide ventriculography in patients with right ventricular dysfunction.

    Science.gov (United States)

    Bontemps, L; Merabet, Y; Chevalier, P; Itti, R

    2013-01-01

    Gated radionuclide ventriculography (RNV) may be used for the evaluation of the right ventricular function. However, the accuracy of the method should be clinically validated in patients suffering from diseases with specific pathology of the right ventricle (RV) and with possible left ventricular (LV) interaction. Three groups of 15 patients each, diagnosed with arrhythmogenic right ventricular dysplasia (ARVD), pulmonary artery hypertension (PAH) or atrial septal defect (ASD) were compared to a group of normal subjects. The parameters for both ventricles were evaluated separately (ejection fractions: LVEF and RVEF, and intraventricular synchronism quantified as phase standard deviation: LVPSD and RVPSD) as well as the relation or interdependence of the right to left ventricle (RV/LV volume ratio, LV/RV ejection fraction and stroke volume ratios, and interventricular synchronism). All the variables as a whole were analyzed to identify groups of patients according to their functional behaviour. Significant differences were found between the patients and control group for the RV function while the LV function remained mostly within normal limits. When the RV function was considered, the control group and ASD patient group showed differences regarding the ARVD and PAH patients. On evaluating the RV/LV ratios, differences were found between the control group and the ASD group. In the PAH patients, LV function showed differences in relation to the rest of the groups. RNV is a reliable clinical tool to evaluate RV function in patients with RV abnormality. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  6. The value of exercise radionuclide ventriculography in risk stratification after coronary arterial bypass grafting

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Goel, I.P.; Mundth, E.D.; Kane, S.; Schenk, C.

    1985-01-01

    Cardiac events after coronary artery bypass surgery (CABG) may be related to left ventricular (LV) function, residual coronary artery diseases (CAD), graft occlusion, and progression of CAD. This study examined the value of rest and exercise (EX) radionuclide ventriculography (RNV) done 3-6 mos after CABG in risk stratification in 212 pts. There were 185 men and 27 women, aged 57 +- 8 years (mean +- SD). During a followup period of up to 4 years, (15 +- 10 months), there were 23 cardiac events; 13 pts died of cardiac causes and 20 had non-fatal acute myocardial infarctions. The pts with and without events did not differ in: clinical presentation after CABG (most were asymptomatic), medications and ECG findings at rest and EX. The pts with events had lower EX systolic blood pressure (p < 0.01); resting LV ejection fraction (EF) (p = 0.002), and EX EF (40 +- 18% vs 54 +- 16%, p = 0.002). The change in EF (rest to EX) was not significantly different (l.6 +- 8.2%, vs 2.1 +- 9.2%). Survival analysis (Cox model) identified the EX EF as the best predictor of death and total events (X/sup 2/ = 4.3 and 2.4, p = 0.04 and 0.07 respectively). Actuarial life table analysis showed that the risk increased as the EX EF decreased when pts were grouped into EX EF ≥ 50, 30-49, and <30%, (p < 0.001, Mantel-Cox). Thus, EX RNA is useful in risk stratification after CABG. The EX LVEF is an important descriptor that categorizes pts into different risks groups. The pts at high risk probably require more aggressive followup and continued medical therapy

  7. A study of the global and regional ventricle function using radionuclide ventriculography in the cases of patients with and without KHK under nitrate and placebo

    International Nuclear Information System (INIS)

    Kroth, B.

    1983-01-01

    In a controlled study of 74 patients with coronary heart disease (KHK) or without provable heart disease the ventricle function at rest and under ergonomic load before and after oral administration of nitrates, respectively placebos was studied with the help of radionuclide ventriculography. Radionuclide ventriculography proved itself thereby as a valuable method of high sensitivity for the recognition of KHK. The stress test increases the sensitivity and allows inferences to be made on the extent of the ischemia. The global function at rest is more a parameter for the functional restriction by infarct scars. A quantitative regional evaluation also makes possible the recognition of minor local changes. The additional study after nitrate administration allows a basis for the extent of reversibility in the stress-dependent functional restriction. The effects of a drug therapy become extrinsically presentable as a result of radionuclide ventriculography. (TRV) [de

  8. Digital subtraction ventriculography for assessment of global and regional leftventricular parameters in comparison to conventional contrast ventriculography

    International Nuclear Information System (INIS)

    Eichstaedt, H.; Langer, M.; Felix, R.

    1984-01-01

    Since May 1982 we studied more than 100 patients with heart diseases by means of digital angiography, out of them 46 patients with a history of transmural myocardial infarction were selected. Urografin 76, 30 ml, was administered at a flow rate of 18 ml/s by means of a catheter in the superior vena cava during digital subtraction ventriculography. Results were compared with conventional contrast ventriculograms. The correlation coefficient was r=0.93 (p 0.001) for determination of ejection fraction with both methods. The data in individual cases suggest that DSV is more sensitive than conventional contrast ventriculography in determination of severely reduced ejection fractions. The methods are practically identical in qualitative evaluation of disorders of regional wall motion in the anterolateral region, while DSV is more sensitive than conventional ventriculography in evaluating the apical region. Sensitivity was 85.7% when the two methods were compared in evaluation of the inferior region of the left ventricle. Both methods are identical in demonstration of severely deformed ventricles. Digital subtraction ventriculography may replace conventional contrast ventriculography in some of situations discussed above. (orig.)

  9. Quantitative analysis of cardiac function: Comparison of electrocardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Ziada, G.; Abdel-Dayem, H.M.; Higazy, E.; Mohamed, M.M.; Bahar, R.; Hayat, N.; Yousof, A.M.

    1987-03-01

    A dual gated tomography (DGT) program for end systolic and end diastolic acquisition and subsequent processing for calculation of LVEF, end diastolic and end systolic volumes (EDV, ESV) has been evaluated in 20 healthy volunteers (25 years-40 years) and 45 patients (25 years-60 years): 20 with ischaemic heart disease and 25 with valvular heart disease (VHD). All had biplane multigated blood pool (MUGA) studies in the 40/sup 0/ LAO projection using in vivo /sup 99m/Tc-R BCs, immediately followed by DG. The results in the patients group were correlated with contrast ventriculography (CV). In the volunteer group, the normal values for LVEF, EDV and ESV measured with DGT were found to be 63%+10%, 91 ml + 6 ml and 30 ml + 6ml and r value for the LVEF=0.91 compared with MUGA. In the IHD group, r values compared with CV were 0.915 and 0.97 for the EDV and ESV and 0.934 for the LVEF. Compared with the MUGA, the r value for LVEF was 0.883. In the VHD group, r values were 0.98 for both the EDV and ESV and 0.948 for the LVEF (P<0.002) compared with CV and 0.789 for the LVEF compared with the MUGA. We feel that DGT is an accurate and reproducible technique for LV function measurements.

  10. Application of radionuclide ventriculography phase analysis in patients with atrial or ventricular pacing for detecting ventricular abnormal excitation

    International Nuclear Information System (INIS)

    Shi Rongfang; Wang Zhonggan; Li Shengting

    1996-01-01

    The aim of the study was to increase the accuracy of detecting ventricular abnormal excitation. During atrial or ventricular pacing, radionuclide ventriculography phase analysis (RNV-PA) was performed in 17 patients with Wolff-Parkinson-White (W-P-W) syndrome and paroxysmal supra ventricular tachycardia (PSVT) and ventricular tachycardia (PVT). During pacing, detection rate of abnormal excitation by RNV-PA was 95.5%, compared with 68.2% during basic conduction. Atrial or ventricular pacing can significantly increase the detection rate of abnormal excitation by RNV-PA in patients with W-P-W syndrome. It may be a valuable method for identifying the abnormal excitation and estimating the therapeutic effect of ablation

  11. How to accurately assess the clinical value of isometric exercise radionuclide ventriculography in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Yang Shunfang; Zhu Huiping; Zeng Jun; Xie Wenhui; Yu Zhichang

    2001-01-01

    To assess the influence of isometric handgrip exercise on left ventricular function by radionuclide ventriculography in patients with coronary artery disease (CAD). Using gated equilibrium radionuclide ventriculography, parameters of left ventricular function were analyzed at rest and during 30% sustained handgrip (HNG) for 5 - 10 minuets in 8 normal control subjects and 38 consecutive CAD patients. All investigated subjects were also performed coronary arteriography within 2 weeks. Results showed that at rest, left ventricular ejection fraction (LVEF), peak filling rate (PFR), end-diastolic volume (EDV), end-systolic volume (ESV) and heart rate (HR) were reduced in one-vessel, two-vessel and three-vessel of stenosis patient group (53.67 +- 5.0)%, (52.47 +- 8.26)%, (52.81 +- 8.89)%; 2.87 +- 0.29, 2.71 +- 0.88, 3.07 +- 0.71 end-diastolic volume per second (EDV/s); 1.36 +- 0.05, 1.34 +- 0.06, 1.34 +- 0.06; 0.62 +-0.06, 0.66 +- 0.06, 0.65 +- 0.1; 69.67 +- 8.14, 72.85 +- 10.5, 76.56 +- 18.04 (min -1 ), respectively, as compared with controls (57 +- 10.45)%, p = NS; 2.94 +- 0.44 (EDV/s), p = NS; 1.38 +- 0.15, p = NS; 0.59 +- 0.11, p = NS; 72.88 +- 8.25 (min -1 ), p = NS, respectively. During HNG exercise using both hands, the indexes were reduced in CAD patients (54.44 +- 5.66)%, (48.84 +- 8.70)%, (45.25 +- 8.69)%; 2.75 +- 0.39, 2.50 +- 0.68, 2.22 +- 0.58 (EDV/s); 1.36 +- 0.05, 1.31 +- 0.06, 1.26 +- 0.07; 0.61 +- 0.07, 0.69 +- 0.06, 0.71 +- 0.09; 81.33 +- 8.92, 84.46 +- 14.29, 90.56 +- 26.54 (min -1 ), respectively, as compared with controls (59.38 +- 9.44)%, p = NS; -1 ), p = NS, respectively. The four protocols of CAD diagnosis were 1. LVEF <55% and ΔPFR < 0 EDV/s at rest (Δ value = during HNG value-rest value); 2. LVEF <55% during HNG and ΔPFR <0 EDV/s; 3. ΔLVEF <0% and ΔPFR <0 EDV/s; 4. ΔEF <0%. Their sensitivity, specificity and accuracy were 45%, 53%, 66%, 76%, 100%, 100%, 87.5%, 87.5%, 54%, 61%, 70%, 78%, respectively. The isomeric exercise radionuclide

  12. Atrial pacing as an alternative to supine exercise (SE) in radionuclide ventriculography (RNV)

    International Nuclear Information System (INIS)

    Le Grand, V.; Wells, S.; O'Neil, W.W.; Jenkins, J.; Gross, M.D.; Vogel, R.

    1984-01-01

    Stress RNV is at times of limited value as many patients cannot achieve a sufficient pressure rate product (PRP). Atrial pacing is a noninvasive alternative to SE by bicycle ergometry. A swallowable electrode attached to a flexible wire is positioned in a retroatrial position in the esophagus and when connected to a variable output stimulator, variable rate (120, 140, 160 beats/min) atrial pacing ventriculography (APV) can be performed. RNV is performed in the sitting position at rest and at each pacing stage. APV was compared to SE RNV in 4 patients with coronary artery disease (CAD) and 3 normal volunteers (N). Tolerance to APV was excellent with adequate pacing. All subjects reported a minor sensation of chest burning. No arrhythmias occurred. At maximal APV mean PRP was 174 +- 26. The diastolic volumes in APV fell in all patients. Systolic volumes fell in N but not in CAD to APV. A flat EF response to APV was seen in both N and CAD patients. APV is an alternative to SE RNV although PRP remains low. Volume changes in APV are different than in SE RNV and in the interpretation of the results of APV in CAD, changes in systolic and diastolic volumes may be more important than the response of EF

  13. Exercise tolerance in mitral stenosis and chronic obstructive pulmonary disease. Evaluation by anaerobic threshold and radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Uenami, Atsushi; Mizuno, Toshikazu; Chiba, Hiroshi; Ohno, Masanori; Wakino, Kouichi; Sawada, Yoshihiro; Ohno, Joichi; Kume, Kiyoshi

    1986-06-01

    Serial radionuclide ventriculography was performed using a newly developed ''real-time'' system, and left ventricular ejection fraction (LVEF), right ventricular ejection fraction (RVEF), stroke volume (SV), and cardiac output (CO) were measured during graded supine exercise in five patients with mitral stenosis (MS), in five patients with chronic obstructive pulmonary disease (COPD) and in five healthy subjects. Simultaneous pulmonary gas exchange analysis permitted determining the anaerobic threshold, which is the point during incremental exercise when lactate begins to accumulate in the blood. LVEF at the anaerobic threshold was not significantly changed in any patient groups and in healthy subjects, but RVEF at the anaerobic threshold was lower in COPD and MS patients as compared with healthy subjects. In MS, SV during exercise was reduced at the anaerobic threshold, but not in COPD or in healthy subjects. In conclusion, reduced working capacity is related to decreased RVEF in both COPD and MS, but the inhibited increase in CO during exercise is also important for the working capacity in MS.

  14. Can isosorbide dinitrate (ISDN) prevent myocardial ischemia during exercise in patients with coronary artery disease; An assessment with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Aoki, Toshikazu; Okamoto, Shinya; Setsuda, Morimichi; Futagami, Yasuo; Nakano, Takeshi (Mie Univ., Tsu (Japan). School of Medicine)

    1989-12-01

    The effects of sublingual isosorbide dinitrate (ISDN) on left ventricular function during exercise were evaluated in 8 patients with coronary artery disease. ECG gated multistage exercise radionuclide ventriculography (RNV) was performed to assess the global and regional left ventricular function before and after sublingual ISND. Chest pain during exercise was observed in six patients (75%) during exercise but subsided negative ISDN. Left ventricular ejection fraction (LVEF) during stress did not show improved significant change during exercise (from 64.4 {plus minus} 8.7% to 64.6 {plus minus} 8.3%) but increased significantly from 66.0 {plus minus} 6.3% to 69.9 {plus minus} 8.6% after ISDN. Left ventricular end-systolic volume increased during exercise from 56.9 {plus minus} 19.6 ml to 68.0 {plus minus} 15.9 ml, but the increase was suppressed (from 49.1 {plus minus} 11.0 ml to 44.5 {plus minus} 15.5 ml) after ISDN. ISDN prevented not only cardiac symptoms nor ECG changes but also improved abnormal left ventricular function during exercise. (author).

  15. Can the diagnostic accuracy of radionuclide ventriculography during exercise be improved by means of a step-up loading procedure?

    International Nuclear Information System (INIS)

    Ruegenberg, T.

    1985-01-01

    34 patients (31 of whom were coronary heart disease sufferers as proven by angiography) and further 3 patients failing to show symptoms of this disorder were subjected to radionuclide ventriculography carried out with the aid of 99m Tc-labelled erythrocytes in such a way that examinations at rest were directly followed by maximum loading tests. In a second series of examinations a step-up procedure was adopted where initial recordings at rest were followed by preliminary exercise tests using only 25% of the maximum load. The parameters chosen to evaluate the results were heart rate, ejection fraction, maximum velocity of changes in volume, endsystolic and enddiastolic volumes (ESV and EDV) as well as cardiac output. In 23 patients the preliminary exercise test revealed an insufficient increase or even decrease of the ejection fraction that was associated with delayed volume changes, increases in ESV and EDV as well as reductions in cardiac output and in 21 patients it became evident during those examinations that the onset of stenocardiac complaints was preceded by markedly pronounced function disorders in the left ventricle. It was concluded from these findings that the step-up procedure followed here may in some patients provide additional information on the level of myocardial performance. It can thus be assumed to contribute considerably to higher diagnostic accuracy, although it requires no more time than conventional exercise tests and is not associated with additional radiation exposure. (TRV) [de

  16. Attempts at diagnostic differentiation between dilatory cardiomyopathy and coronary heart disease on the basis of radionuclide ventriculography

    International Nuclear Information System (INIS)

    Hefermann, R.

    1989-01-01

    It was the purpose of this study to find out which of the various parameters of radionuclide ventriculography would be suitable to determine whether a patient suffers from dilatory myocardiopathy (MCP) or coronary heart disease (CHD). Two groups of patients were examined using a mathematical procedure known as analysis of discriminance, in which the weights that individual parameters would have in a separation function were determined with the help of a computer programme. On the basis of these data, attempts were made to assign the patients of the different diagnostic groups. The parameters registered at rest, which were FSMIN, EFAFI (end of fast filling) and CONTR (contraction), led to a total of five diagnostic errors, with one case of CHD being classified as CMP and four CMP patients as having CHD. On the basis of the parameters measured during exercise), which were RELAX (relaxation), stroke volume and PETI (peak ejection time), only one CMP patient was erroneously assigned to the CHD group. When the parameters of RNV at rest and during exercise were combined to give FSMINR (minimum of highest factor minus lowest factor at rest), DFSDIFF (difference between F-S at rest and during exercise) and DMINVOL (difference between heart minute volumes at rest and during exercise), the classifications were correct for all of the 30 study participants (100%). This led us to conclude that the RNV parameters chosen permitted reliable diagnostic discriminations to be made between those two groups of patients. (orig./MG) [de

  17. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    International Nuclear Information System (INIS)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.; Kass, R.M.; Raymond, M.J.; Garcia, E.V.; Chaux, A.; Matloff, J.M.; Berman, D.S.

    1984-01-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and left ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers

  18. Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure

    International Nuclear Information System (INIS)

    Kipper, S.L.; Ashburn, W.L.; Norris, S.L.; Rimkus, D.S.; Dillon, W.A.

    1985-01-01

    Graded, sequential, rest/exercise, gold-195m, first-pass ventriculography and thallium-201 (Tl-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal T1-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. The authors suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combing Au-195m ventriculography and Tl-201 SPECT imaging into a single, noninvasive, diagnostic package

  19. Combined evaluation of first-pass radionuclide angiography and epuilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. Pt. 1

    International Nuclear Information System (INIS)

    Knesewitsch, P.; Kleinhans, E.; Buell, U.

    1986-01-01

    The results of 203 patients who underwent first-pass radionuclide angiography (FP), as well as quantitative equilibrium radionuclide ventriculography (qERNV), were stored in a data base system and evaluated statistically. In patients with coronary artery disease (CAD) without previous myocardial infarction (MI), evaluation of global and regional ejection fraction (gEF, rEF) at rest revealed a poor sensitivity of 64% (Rest-qERNV) and 69% (Rest-FP), respectively. In patients with a history of one previous MI, the sensitivity of both methods was equivalent: FP 87% and qERNV 84%. In patients with several MIs, sensitivity was higher than 90%. Concerning localization of MI, remarkable differences between FP and qERNV were found. In posterior wall infarction, the FP sensitivity was 87% and qERNV only 67%, whereas in anterior wall infarction, the results were similar for both methods.: 93% (FP) and 96% (qERNV), respectively. Since 30 0 RAO camera position achieves the best visualization of the anterior and posterior wall, FP is superior to qERNV in the evaluation of posterior wall asynergies. In addition, qERNV often fails to discriminate anterior and posterior wall motion abnormalities. (orig.)

  20. Left ventricular performance at rest and during peak exercise in never-treated hypertensive female - an assessment with radionuclide ventriculography

    International Nuclear Information System (INIS)

    Topuzovic, N.; Karner, I.; Rusic, A.; Krstonosic, B.

    2002-01-01

    Aim: The aim of this study was to investigate left ventricular performance and exercise tolerance in never-treated female hypertensive patients. Materials and Methods: Seventeen female patients with newly established, uncomplicated essential hypertension (aged 25 to 57 years) were evaluated with rest-stress radionuclide gated ventriculography, and were compared to 23 age-matched normotensive female volunteers. Results: Mean blood pressure was significantly higher in patients at rest and during exercise than in controls (121±13 vs. 89±7 mm Hg, and 143±11 vs. 122±9 mm Hg, respectively, p 2 , respectively, p<0.01), while ESV was similar in both groups. Ejection fraction (EF) at rest and stress did not differ significantly (54±10 vs. 55±8%, and 70±10 vs. 66±8%, respectively), but % rise in EF during exercise was significantly higher in patients. At rest and during exercise, there were no significant difference in peak ejection rate (PER) and time to PER (TPER) between patients and controls. Patients had similar peak filling rate (PFR) at rest (2.88±0.79 vs. 2.76±0.76 EDV/s) and during exercise (5.85±1.86 vs. 6.21±1.97 EDV/s), in addition to nonsignificant difference in time to PFR (at rest 143±62 vs. 146±42 ms at rest, and 97±20 vs. 91±19 ms during exercise). Conclusion: Female patients with newly diagnosed, never-treated hypertension have preserved maximal exercise performance, systolic function and diastolic function, but they have significant enlargement of EDV and elevated cardiac output during exercise

  1. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-02-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8{+-}1.4 degrees vs. 14.6{+-}2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9{+-}23.7% whereas that in VAP patients was -9.1{+-}17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  2. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography

    International Nuclear Information System (INIS)

    Wu, Jin; Takeda, Tohoru; Ajisaka, Ryuichi; Masuoka, Takeshi; Watanabe, Sigeyuki; Sato, Motohiro; Itai, Yuji; Toyama, Hinako; Ishikawa, Nobuyoshi

    1999-01-01

    To understand the effect of hyperventilation (HV) stress in patients with spastic angina, left ventricular (LV) contraction was analyzed by quantitative phase analysis. The study was performed on 36 patients with spastic angina pectoris, including vasospastic angina pectoris (VspAP: 16 patients) and variant angina pectoris (VAP: 20 patients). First-pass radionuclide ventriculography (first-pass RNV) was performed at rest and after HV stress, and standard deviation of the LV phase distribution (SD) was analyzed. The SD was lower in patients with VspAP than in VAP(12.8±1.4 degrees vs. 14.6±2.2 degrees, p<0.005) at rest. After HV stress, the SD (HVSD) tended to increase in VspAP patients (62.5%), whereas the SD decreased in VAP patients (70%). Due to HV stress, the percentage change in SD (%SD) in VspAP patients was 8.9±23.7% whereas that in VAP patients was -9.1±17.3% (p<0.01). Moreover, phase histograms were divided into HVSD increase and HVSD decrease groups. The HVSD increase group had a decrease of HVEF, but the HVSD decrease group tended to have more decreased HVEF than the HVSD increase group. These results indicate that spastic angina pectoris patients show various responses to HV stress. The HVSD increase group might have additional myocardial ischemia due to regional coronary spasm. In contrast, in the HVSD decrease group severe LV dysfunction or diffuse wall motion abnormality might have been generated, and this caused a reduction in the SD value. Phase analysis would therefore add new information regarding electrocardiographically silent myocardial ischemia due to coronary spasm, and HV stress might increase sensitivity for the detection of abnormalities in quantitative phase analysis, especially in VspAP patients. (author)

  3. Fourier phase analysis on equilibrium gated radionuclide ventriculography: range of phase spread and cut-off limits in normal individuals

    International Nuclear Information System (INIS)

    Ramaiah, Vijayaraghavan L.; Harish, B.; Sunil, H.V.; Selvakumar, Job; Ravi Kishore, A.G.; Nair, Gopinathan

    2011-01-01

    To define the range of phase spread on equilibrium gated radionuclide ventriculography (ERNV) in normal individuals and derive the cut-off limit for the parameters to detect cardiac dyssynchrony. ERNV was carried out in 30 individuals (age 53±23 years, 25 males and 5 females) who had no history of cardiovascular disease. They all had normal left ventricular ejection fraction (LVEF 55-70%) as determined by echocardiography, were in sinus rhythm, with normal QRS duration (≤120 msec) and normal coronary angiography. First harmonic phase analysis was performed on scintigraphic data acquired in best septal view. Left and right ventricular standard deviation (LVSD and RVSD, respectively) and interventricular mechanical delay (IVMD), the absolute difference of mean phase angles of right and left ventricle, were computed and expressed in milliseconds. Mean + 3 standard deviation (SD) was used to derive the cut-off limits. Average LVEF and duration of cardiac cycle in the study group were 62.5%±5.44% and 868.9±114.5 msec, respectively. The observations of LVSD, RVSD and right and left ventricular mean phase angles were shown to be normally distributed by Shapiro-Wilk test. Cut-off limits for LVSD, RVSD and IVMD were calculated to be 80 msec, 85 msec and 75 msec, respectively. Fourier phase analysis on ERNV is an effective tool for the evaluation of synchronicity of cardiac contraction. The cut-off limits of parameters of dyssynchrony can be used to separate heart failure patients with cardiac dyssynchrony from those without. ERNV can be used to select patients for cardiac resynchronization therapy. (author)

  4. The value of exercise radionuclide ventriculography in risk stratification in patients with known or suspected coronary artery disease

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane, S.; Schenk, C.

    1985-01-01

    This study examined the value of rest and exercise (EX) radionuclide ventriculography (RNV) in risk stratification in 392 pts with suspected or known coronary artery disease who were being evaluated for anginal symptoms. There were 289 men and 203 women, aged 55 +- 12 years (mean +- SD). There were 20 cardiac events in the followup period of up to 4 years (19 +- 10 months): 14 pts died of cardiac causes and 6 had non-fatal acute myocardial infarctions. The pts with and without events did not differ in age, clinical presentation, risk factors, and rest and EX ECGs. However, pts with events had lower EX systolic blood pressure (p < 0.02); lower EX duration; (5.5 +- 2.5 vs 7.6 +- 3.7 minutes, p < 0.0l), lower resting left ventricular (LV) ejection fraction (EF) (p = 0.001), and lower EX EF (35 +- 17% vs 56 +- 15%, p = 0.0001). The change in EF from rest to EX was not significantly different (-0.1 +- 6.1 vs 3 +- 9.9). Univariate survival analysis (Cox model) showed several descriptors related to prognosis: EX EF, rest EF, wall motion and EX duration. Multivariate analysis, however, identified the EX EF as the only significant predictor (X/sup 2/ = 19.9). None of the other variables added independent information to that provided by the EX EF. Actuarial lie table analysis showed that the risk increased as the EX EF decreased, when pts were grouped into those with EXEF ≥ 50%, 30-49%, and <30%., (p = 0.001, Mantel-Cox). Thus, the EX RNV is useful in risk stratification; the EX EF is the best descriptor that categorizes pts into different risk groups

  5. Computer analysis of the exercise electrocardiogram and control of radionuclide ventriculography: an optimal statistical decision model for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Hsia, P.W.E.

    1987-01-01

    A new automated technique for the diagnosis of coronary artery disease (CAD) by stress electrocardiography and radionuclide ventriculography (RNV) has been developed. The method employs digital signal processing of the electrocardiogram (ECG) for recognition of ischemic and arrhythmic events. On-line detection of abnormal beats is used for control image acquisition by the gamma camera resulting in improved image quality since only identical beats are included in the composite images of the cardiac cycle. A combined stress ECG analysis which measures ST changes indicative of ischemia, and radionuclide results, which reveal corresponding ejection fraction abnormalities yields greater sensitivity and specificity than either test alone. Digitized data from the electrocardiogram are analyzed in a beat-by-beat mode and a contextual diagnosis of underlying rhythm is given. Template generation, R wave detection, QRS window size, baseline correction, and continuous updating of heart rate are completely automated. A statistical model base on computerized ST segment measurements combined with radionuclide ventriculography data has been developed by using a logistic model with stepwise regression fitting. A previously acquired database of similar measurements was used for designing the model. The most significant parameters were found to be (1) ejection fraction of exercise RNV; (2) difference of ST level between exercise and resting test (stdif); and (3) ejection fraction difference between exercise and resting test. The new parameter stdif, not previously used in ECG interpretation, was found to be of great diagnostic significance

  6. Cardiac ventriculography

    International Nuclear Information System (INIS)

    Hillis, L.D.; Grossman, W.

    1986-01-01

    Cardiac ventriculography has been used extensively to define the anatomy of the ventricles and related structures in patients with congenital, valvular, coronary, and cardiomyopathic heart disease. Specifically, left ventriculography may provide valuable information about global and segmental left ventricular function, mitral valvular incompetence, and the presence, location, and severity of a number of other abnormalities, including ventricular septal defect and hypertrophic cardiomyopathy. As a result, it should be a routine part of catheterization in patients being evaluated for coronary artery disease, aortic or mitral valvular disease, unexplained left ventricular failure, or congenital heart disease. Similarly, right ventriculography may provide information about global and segmental right ventricular function and can be especially helpful in patients with congenital heart disease

  7. Visualisation of regional motility disorders in the left ventricular wall using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Kaiser, H.

    1985-01-01

    During this study ECG-triggered intramyocardial scintiscans were obtained following in-vivo labelling of erythrocytes (99mTc) from 74 patients showing coronary heart disease and analysed with the aim to assess the suitability of this method for the detection of mural motility disorders and for visualisation of the accurate size of the left ventricle. The results of the intramyocardial scintiscans were evaluated against those of levocardiograms recorded for reasons of comparison and found to demonstrate mural motility disorders with a specifity of 0.70 and a sensitivity of 0.75. Relatively reliable data to diagnose those myocardial motility disorders were obtained by combined analysis of the individual scintiphotographic displays of amplitudes, phases, ejection fractions and positive gradients. The investigation of further parameters like the recorded stroke volumes and negative gradients provided no additional information. The phase recording proved to be the most suitable parameter to assess the size of the left ventricle. All other recordings gave a distorted picture of the left ventricle in terms of a reduction in size. (TRV) [de

  8. Measurement of left ventricular ejection fraction using gated 99mTc-sestamibi myocardial planar images: Comparison to contrast ventriculography

    International Nuclear Information System (INIS)

    Parker, D.A.; Lloret, R.L.; Barilla, F.; Douthat, L.; Gheorghiade, M.

    1991-01-01

    Using the new myocardial perfusion agent 99mTc-sestamibi and multigated acquisition on a nuclear medicine gamma camera, the left ventricular ejection fraction (LVEF) was derived in 13 patients with coronary artery disease (CAD). Cross-sectional activity profiles were used to measure the left ventricle from end-diastolic and end-systolic images. Several different geometric methods were then utilized to derive ejection fractions from the nuclear data. Comparison of the resultant ejection fractions to those obtained from contrast ventriculography showed significant correlation for all geometric methods (P less than 0.01, Sy X x = 6.2 to 9.6). The authors conclude that in patients with CAD one or more of these simple geometric methods can provide a useful estimate of the LVEF when performing 99mTc-sestamibi multigated myocardial perfusion imaging

  9. The significance of abnormal systolic blood pressure response during supine ergometer exercise and postexercise in ischemic heart disease, studied by exercise radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ajisaka, Ryuichi; Watanabe, Shigeyuki; Masuoka, Takeshi

    1989-01-01

    Abnormal response to blood pressure (BP) during exercise and postexercise was examined in 169 patients with ischemic heart disease. The patients underwent supine ergometer exercise gated equilibrium radionuclide ventriculography and coronary arteriography. When BP during exercise did not increase by at least 11 mmHg or initially increased but later decreased by more than 10 mmHg, the BP response was defined as abnormal during exercise. A postexercise BP increase of more than 10 mmHg above the peak exercise BP was defined as abnormal during postexercise. Fifteen-one patients (30%) were classified as abnormal (group 1) and the other 118 as normal (group 2). Abnormal BP response fell into three types: (1a) exercise hypotension (n=11), (1b) postexercise hypertension (n=30), and (1c) exercise hypotension with postexercise hypertension (n=10). Both average exercise duration and peak heart rate were significantly lower in groups 1a, 1b, and 1c than group 2. Exercise ST-segment depression was more noticeable in groups 1b and 1c than group 2. However, there was no significant difference in the severitiy of exercise ST-segment depression between groups 1a and 2. A decline in ejection fraction occurred more frequently in groups 1b and 1c than group 2. Patients in groups 1a, 1b, and 1c had more extensive coronary artery disease than did patients in group 2. Medically managed patients having an abnormal BP response had a poorer prognosis than those with a normal BP response. An abnormal BP response during both supine exercise and postexercise was infrequent. The abnormal BP during exercise may be usually associated with impaired exercise tolerance and severe coronary artery disease; and that during postexercise may be closely associated with myocardial ischemia and global left ventricular dysfunction. Postexercise hypertension may be of the same value as exercise hypotension in predicting poor prognosis. (Namekawa, K)

  10. Incremental value of clinical assessment, supine exercise electrocardiography, and biplane exercise radionuclide ventriculography in the prediction of coronary artery disease in men with chest pain

    International Nuclear Information System (INIS)

    Currie, P.J.; Kelly, M.J.; Harper, R.W.; Federman, J.; Kalff, V.; Anderson, S.T.; Pitt, A.

    1983-01-01

    The incremental value of clinical assessment, exercise electrocardiography (ECG) and biplane radionuclide ventriculography (RVG) in the prediction of coronary artery disease (CAD) was assessed in 105 men without myocardial infarction who were undergoing coronary angiography for investigation of chest pain. Independent clinical assessment of chest pain was made prospectively by 2 physicians. Graded supine bicycle exercise testing was symptom-limited. Right anterior oblique ECG-gated first-pass RVG and left anterior oblique ECG-gated equilibrium RVG were performed at rest and exercise. Regional wall motion abnormalities were defined by agreement of 2 of 3 blinded observers. A combined strongly positive exercise ECG response was defined as greater than or equal to 2 mm ST depression or 1.0 to 1.9 mm ST depression with exercise-induced chest pain. A multivariate logistic regression model for the preexercise prediction of CAD was derived from the clinical data and selected 2 variables: chest pain class and cholesterol level. A second model assessed the incremental value of the exercise test in prediction of CAD and found 2 exercise variables that improved prediction: RVG wall motion abnormalities, and a combined strongly positive ECG response. Applying the derived predictive models, 37 of the 58 patients (64%) with preexercise probabilities of 10 to 90% crossed either below the 10% probability threshold or above the 90% threshold and 28 (48%) also moved across the 5 and 95% thresholds. Supine exercise testing with ECG and biplane RVG together, but neither test alone, effectively adds to clinical prediction of CAD. It is most useful in men with atypical chest pain and when the ECG and RVG results are concordant

  11. Myocardial perfusion and left ventricular function during exercise evaluated by 201Tl myocardial scintigraphy and 99mTc radionuclide ventriculography in patients treated with PTCA

    International Nuclear Information System (INIS)

    Honda, Toshio; Jo, Tadafumi; Doiuchi, Junji

    1992-01-01

    To evaluate the effects of percutaneous transluminal coronary angioplasty (PTCA), we investigated myocardial ischemia and left ventricular function during exercise before and after successful PTCA in 30 patients. We used extent and severity scores of 201 thallium ( 201 Tl) exercise myocardial scintigraphy to assess myocardial ischemia and determined global and regional left ventricular ejection fraction (EF and REF) of 99m Tc-RBC exercise radionuclide ventriculography to assess left ventricular function. The extent and severity scores of stress images were significantly less after PTCA than before PTCA. The scores of the redistribution images were unchanged before and after PTCA. Global EF during exercise was significantly higher after PTCA than before PTCA. There was no difference in resting global EF between before and after PTCA. Myocardial ischemia induced by exercise was semi-quantitatively analyzed as transient perfusion defect with severity score. Severity score was significantly less after PTCA than before PTCA. ΔEF, which was obtained by subtraction of resting global EF from exercise one, was significantly higher after PTCA than before PTCA. However, the degree of improvement in myocardial ischemia and left ventricular function varied from patient to patient. In 17 patients with one-vessel left anterior descending artery disease, ΔREF, which was determined by subtracting resting regional EF from exercise one, was significantly higher in septal and apical segments after PTCA than before PTCA. Myocardial ischemia and left ventricular function under exercise were alleviated by PTCA. However, the degree of improvement varied from patient to patient and it might have been affected by various factors including coronary dissection, edema, thrombus, restenosis, spasm, side branch stenosis or occlusion, distal thrombus, and myocardial hibernation. (author)

  12. Regional rates of myocardial fatty acid metabolism: Comparison with coronary angiography and ventriculography

    International Nuclear Information System (INIS)

    Schad, N.; Vattimo, A.; Bertelli, P.

    1990-01-01

    In 50 patients, 1 mCi 123 I phenylpentadecanoic acid (IPPA) was injected at peak ergometric stress and 1500 frames were acquired (1 frame/s) with a high count rate gamma camera. Parametric images of rates of decrease and increase for different time intervals after stress were compared with coronary angiography and LV ventriculography, separately evaluating the 3 main coronary territories: 18/150 territories supplied by normal coronaries presented rather homogeneous regional clearing rates, whereas a gradual decrease in clearing rates towards the end of the territory (frequently with peripheral defects) was seen in all 87/150 territories with significant coronary narrowing. In local correspondence to clearing defects, initial IPPA accumulations could be observed with later onset of clearing between 10 and 25 min. In all 44/150 territories presented abnormal clearing rates, mostly with a patchy pattern, with normal coronary anatomy, but all except one had LV dysfunction and a clinical diagnosis of cardiomyopathy, diabetes mellitus or hypertensive disease. Twenty four of the 41 patients with CAD had, in correspondence to a prior myocardial infarction, minimum or missing metabolic activity frequently in circumscribed zones, partly separated by bridges of still viable tissue with preserved but reduced clearing rates. (orig.)

  13. Regional rates of myocardial fatty acid metabolism: comparison with coronary angiography and ventriculography.

    Science.gov (United States)

    Schad, N; Wagner, R K; Hallermeier, J; Daus, H J; Vattimo, A; Bertelli, P

    1990-01-01

    In 50 patients, 1 mCi 123I phenylpentadecanoic acid (IPPA) was injected at peak ergometric stress and 1500 frames were acquired (1 frame/s) with a high count rate gamma camera. Parametric images of rates of decrease and increase for different time intervals after stress were compared with coronary angiography and LV ventriculography, separately evaluating the 3 main coronary territories: 18/150 territories supplied by normal coronaries presented rather homogeneous regional clearing rates, whereas a gradual decrease in clearing rates towards the end of the territory (frequently with peripheral defects) was seen in all 87/150 territories with significant coronary narrowing. In local correspondence to clearing defects, initial IPPA accumulations could be observed with later onset of clearing between 10 and 25 min. 44/150 territories presented abnormal clearing rates, mostly with a patchy pattern, with normal coronary anatomy, but all except one had LV dysfunction and a clinical diagnosis of cardiomyopathy, diabetes mellitus or hypertensive disease. Twenty four of the 41 patients with CAD had, in correspondence to a prior myocardial infarction, minimum or missing metabolic activity frequently in circumscribed zones, partly separated by bridges of still viable tissue with preserved but reduced clearing rates.

  14. Assessment of right ventricular function with nonimaging first pass ventriculography and comparison of results with gamma camera studies.

    Science.gov (United States)

    Zhang, Z; Liu, X J; Liu, Y Z; Lu, P; Crawley, J C; Lahiri, A

    1990-08-01

    A new technique has been developed for measuring right ventricular function by nonimaging first pass ventriculography. The right ventricular ejection fraction (RVEF) obtained by non-imaging first pass ventriculography was compared with that obtained by gamma camera first pass and equilibrium ventriculography. The data has demonstrated that the correlation of RVEFs obtained by the nonimaging nuclear cardiac probe and by gamma camera first pass ventriculography in 15 subjects was comparable (r = 0.93). There was also a good correlation between RVEFs obtained by the nonimaging nuclear probe and by equilibrium gated blood pool studies in 33 subjects (r = 0.89). RVEF was significantly reduced in 15 patients with right ventricular and/or inferior myocardial infarction compared to normal subjects (28 +/- 9% v. 45 +/- 9%). The data suggests that nonimaging probes may be used for assessing right ventricular function accurately.

  15. Right and left ventricular cardiac function in a developed world population with human immunodeficiency virus studied with radionuclide ventriculography

    DEFF Research Database (Denmark)

    Lebech, Anne-Mette; Gerstoft, Jan; Hesse, Birger

    2004-01-01

    . No correlations were found between reduced cardiac function and levels of the 3 peptides measured. CONCLUSIONS: No major dysfunction of the left ventricle is present in a developed world HIV population. However, a small but significant part of this population has modestly reduced right-sided systolic function.......-associated morbidity and mortality rates. Accordingly, the prevalence of HIV-associated cardiac dysfunction may also have changed. The aim of the study was to establish the prevalence of right- and left-sided cardiac dysfunction in a Danish HIV population, most of whom were undergoing HAART, with radionuclide...... ventricular ejection fraction and 6 (7%) had a reduced right ventricle ejection fraction (0.35-0.42) compared with reference values from the age- and sex-matched reference population. Patients with HIV and reduced cardiac function did not differ in the duration of HIV, CD4 count, CD4 nadir, or HIV RNA load...

  16. The acute hemodynamic effects of intravenous verapamil in coronary artery disease. Assessment by equilibrium-gated radionuclide ventriculography

    International Nuclear Information System (INIS)

    Klein, H.O.; Ninio, R.; Oren, V.; Lang, R.; Sareli, P.; DiSegni, E.; David, D.; Guerrero, J.; Kaplinsky, E.

    1983-01-01

    The acute hemodynamic effects of an i.v. bolus of verapamil, 0.1 mg/kg or 0.06-0.075 mg/kg, were examined by serial radionuclide studies in 46 patients with coronary artery disease. In 20 patients with ejection fractions (EFs) greater than 35% (group 1A), verapamil, 0.1 mg/kg given over 1-11/2 minutes, had a biphasic effect: first, a transient decrease in EF accompanied by increased left ventricular (LV) volumes and cardiac output equivalents; then, an overshoot of EF to values above control, accompanied by a decrease in peripheral vascular resistance and a drastic decrease in LV volumes, while cardiac output equivalent remained slightly elevated. In eight patients with EFs less than 35% (group 1B), only the first effect on EF was noted. In 10 patients with EFs greater than 35% (group 2), verapamil, 0.06-0.075 mg/kg, exerted qualitatively similar but milder effects on hemodynamic function. Finally, verapamil, 0.1 mg/kg given more slowly, over 2-21/2 minutes, produced no significant changes in EF or LV volumes in another eight patients (group 3). The acute effects of verapamil are thus both time-related and dose-dependent. They are also related to the baseline functional reserve of the left ventricle. This study documents that verapamil exerts a depressant effect on LV function. However, the transient nature of this depression and the quick recovery to normal or above-normal values indicate that verapamil, in the doses used in this study, is safe to use intravenously in patients with coronary artery disease

  17. Evaluation of right ventricular function using gated equilibrium blood pool radionuclide ventriculography in patients with congenital volume and pressure overload late after surgical repair

    International Nuclear Information System (INIS)

    Hirata, Nobuaki; Sakakibara, Tetsuo; Watanabe, Shinichiro; Nomura, Fumikazu; Akamatsu, Hiroki; Matsumura, Yasushi; Yamamoto, Kazuhiro; Sasaki, Jiro; Kodama, Kazuhisa

    1991-01-01

    The effects of congenital right ventricular pressure and volume overload were studied in 3 patients with pulmonary stenosis, 7 with atrial septal defect and 6 with atrial septal defect plus pulmonary stenosis late after successful surgical correction. Gated equilibrium blood pool radionuclide ventriculography was used to measure right ventricular function at rest and during exercise and to compare it with eight normal subjects. Right ventricular ejection fractions at rest and during exercise were measured to be 61±9% and 66±13%, respectively, in the group with pulmonary stenosis, 49±7% and 54±8% in the group with atrial septal defect, and 65±13% and 69±13% in the group with atrial septal defect plus pulmonary stenosis. The values in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis were significantly higher than the control subjects (45±5% and 51±5%, p<0.01). The peak filling rate at rest and during exercise was also significantly higher in the groups with pulmonary stenosis and atrial septal defect plus pulmonary stenosis than in controls (at rest, 2.72±0.72, 2.53±0.94 vs. 1.64±0.24 p<0.05; during exercise, 4.38±1.23, 4.13±1.18 vs. 2.25±0.62, p<0.01). When patients with right ventricular systolic pressure equal to or greater than left ventricular systolic pressure and those with right ventricular systolic pressure less than left ventricular systolic pressure were compared, the right ventricular ejection fraction and peak filling rate were greater with the higher pressure at rest (71±10% and 3.12±0.81% vs. 55±3% and 2.30±0.27, p<0.05) and during exercise (75±11% and 4.86±1.01 vs. 59±3% and 2.61±0.35, p<0.05). Postoperative right ventricular hyperfunction may be due to preoperative pressure, but not volume, overload. (author)

  18. Dual-ROI radionuclide ventriculography

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Kanemoto, N.; Maul, F.D.

    1981-01-01

    Accurate determination of the left ventricular activity function is the precondition for a quantitative analysis of the ventricular volume function. During the volume reduction period, extra-myocardial tissue penetrates into the ROI of the late diastole. This curve-distorting activity cannot be eliminated by a single-ROI technique. Of the multiple-ROI techniques, the dual-ROI method is the least complex and tedions and involves the least methodological error. At the time of maximum volume change rates, the curve may be distorted if the late diastolic ROI is inaccurately defined. A method is described which uses only the counting rate over the late diastolic ROI and corrects it only on the basis of the counting rate of the late systolic ROI. The time parameters remain uninfluenced by this correction method while the volumetric parameters are corrected. (orig./APR) [de

  19. Determination of right ventricular ejection fraction from reprojected gated blood pool SPET: comparison with first-pass ventriculography

    International Nuclear Information System (INIS)

    Bartlett, M.L.; Seaton, D.; McEwan, L.; Fong, W.

    2001-01-01

    Gated blood pool (GBP) studies are widely available and relatively inexpensive. We have previously published a simple and convenient method for measuring left ventricle ejection fraction (EF) with increased accuracy from single-photon emission tomography (SPET) GBP scans. This paper describes an extension of this method by which right ventricular EF may also be measured. Gated SPET images of the blood pool are acquired and re-oriented in short-axis slices. Counts from the left ventricle are excluded from the short-axis slices, which are then reprojected to give horizontal long-axis images. Time-activity curves are generated from each pixel around the right ventricle, and an image is created with non-ventricular pixels ''greyed out''. This image is used as a guide in drawing regions of interest around the right ventricle on the end-diastolic and end-systolic long-axis images. In 28 patients, first-pass ventriculography studies were acquired followed by SPET GBP scans. The first-pass images were analysed a total of four times by two observers and the SPET images were analysed three times each by two observers. The agreement between the two techniques was good, with a correlation coefficient of 0.72 and a mean absolute difference between first-pass and reprojected SPET EFs of 4.8 EF units. Only four of the 28 patients had a difference of greater than 8 EF units. Variability was also excellent for SPET right ventricular EF values. Intra-observer variability was significantly lower for SPET than for first-pass EFs: standard error of the estimate (SEE)=5.1 and 7.3 EF units, respectively (P<0.05). Inter-observer variability was comparable in the two techniques (SEE=5.2 and 6.9 EF units for SPET and first-pass ventriculography, respectively). (orig.)

  20. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  1. A prospective comparison between three-dimensional magnetic resonance imaging and ventriculography for target-coordinate determination in frame-based functional stereotactic neurosurgery

    NARCIS (Netherlands)

    Schuurman, P. R.; de Bie, R. M.; Majoie, C. B.; Speelman, J. D.; Bosch, D. A.

    1999-01-01

    OBJECT: The purpose of this prospective study was to compare stereotactic coordinates obtained with ventriculography with coordinates derived from stereotactic computer-reconstructed three-dimensional magnetic resonance (3D-MR) imaging in functional stereotactic procedures. METHODS: In 15

  2. Use of phase images in radionuclide ventriculography for topical diagnosis of the Wolff-Parkinson-White syndrome and sources of abnormal rhythms in the ventricles

    International Nuclear Information System (INIS)

    Ostroumov, E.N.; Sergienko, V.B.; Golitsin, S.P.

    1990-01-01

    The paper presents the results of the mapping of various types of the Wolff-Parkinson-White syndrome and ventricular arrhythmias by using phase images of radionuclide ventriculograms as compared to 12 leads and electrophysiological studies. Phase images are a highly informative method that supplements an electrophysiological study in the topical diagnosis of abnormal tracts and ventricular arrhythmias

  3. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  4. Physical aspects of nuclear ventriculography

    International Nuclear Information System (INIS)

    Alpert, N.M.; Chesler, D.A.; Burnham, C.A.; McKusick, K.A.; Pohost, G.; Dinsmore, R.E.; Brownell, G.L.

    1976-01-01

    The use of edge enhancement and computer motion display improves the detection of regional wall motion abnormalities in the LV. Improved gating and processing techniques should improve the accuracy of ventricular volume vs time measurements. It is hoped that the simulations described will aid in the development of new instrumentation for the collection and analysis of nuclear ventriculographie data

  5. Assessment of left ventricular function: comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis

    International Nuclear Information System (INIS)

    Gottsauner-Wolf, M.; Schedlmayer-Duit, J.; Porenta, G.; Gwechenberger, M.; Huber, K.; Glogar, D.; Probst, P.; Sochor, H.

    1996-01-01

    Measurement of global left ventricular function is important in the follow-up of cardiac patients and is a good prognostic indicator in acute cardiac situations. We compared quantitative measurements of global left ventricular function made with radionuclide angiography (RNA) and contrast cardiac ventriculography (CVG) to visual semiquantitative estimates from two-dimensional echocardiographic images (2D-echo). Three hundred and thirty-nine consecutive patients who underwent RNA were assessed with 2D-echo within 3 months. In addition, 92 of these patients also underwent CVG (correlation of ejection fraction between CVG and RNA: r=0.82; P<0.0001). The RNA mean ejection fractions in the four 2D-echo groups (0=normal, 1=slightly, 2=moderate, or 3=severe reduced left ventricular function) differed markedly (P<0.0001); however, there was overlapping among the groups (2D-echo score/RNA ejection fraction: 0=57.3%±12.8%; 1=46.0%±12.9%; 2=29.6%± 12.2%; and 3=24.6%±11.5%) and the difference between 2D-echo scores 2 and 3 was not significant. 2D-echo showed a good concordance in RNA classes (0=≥505; 1=35%-49%; 2=21%-34%; and 3=≤20% ejection fraction) 0 (133/166; 80%) and 3 (18/30; 60%) but low concordance in classes 1 (27/82; 33%) and 2 (21/61; 34%). For accurate assessment of global left ventricular ejection fraction, visual semiquantitative judgement of a 2D echocardiographic image is limited in comparison to CVG or RNA, especially in patients with a slight or moderate reduction in left ventricular ejection fraction. (orig.). With 2 figs., 2 tabs

  6. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements

    International Nuclear Information System (INIS)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-01-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs

  7. Computed tomography and/or ventriculography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    It is discussed if in intracranial tumors, especially in tumors of the posterior cranial fossa, a CT and/or a ventriculography should be practiced. We have made investigations of 134 patients, 93 of whom were children up to 14 years of age. Each case was undertaken computed tomography as well as ventriculography. The results are clearly demonstrating the superiority of computed tomography compared with ventriculography. Ventriculography is a surgical intervention stressing the patients, side-effects may occur, and sometimes serious complications are caused. Modern computed tomography is producing pictures of high quality, which are highly sufficient for neurosurgical intervention. Very rarely additional angiography has to be performed. The diagnosis of intracranial tumors can fully be established by computed tomography, whereas ventriculography is no longer necessary. (orig.) [de

  8. Scintigraphic ventriculography and stress testing

    International Nuclear Information System (INIS)

    Goris, M.L.; Hung, J.; Debusk, R.F.

    1982-01-01

    Scintigraphic stress ventriculography yields information which is complex and defies description by the difference in ejection fraction between rest and maximum exercise only. The complexity results in part from the ''derived'' nature of the ejection fraction measurement, which is physiologically secondary to stroke volume and end-diastolic volume. Furthermore, the nature of the stress test in which the pulse (stress) is not independent from the response forces an analysis which considers ''when'' as much as ''what'' happens. Automation in data processing, however, has made oversimplification unnecessary and allows a more exhaustive but correct analysis

  9. Comparison of biospheric models of radionuclides transfer

    International Nuclear Information System (INIS)

    Garcia-Olivares, A.; Carrasco, E.

    1992-01-01

    The international BIOMOVS A4 exercise has made possible that a set of biospheric transfer models could predict the daily radionuclide concentration in soils, forage and some animal products (cow milk and beef) after the Chernobyl accident. The aim was to compare these predictions with experimental results in 13 locations around the world. The data provided were essentially the daily air contamination and precipitation and some site-dependent parameters. It was a blind test, the locations and experimental measures were not revealed in advance. Twenty-three models (quasi-steady state and time-dependent models) were involved in the study. In this paper an explicit criterion has been used in order to select the models that better fitted the experimental results. In nine selected locations a comparative analysis between these models has been carried out for obtaining the structural and parametric coincidences that could explain their relatively good performance. The first evidence obtained has been that a wide set of models were able to predict the order of magnitude of the nuclides time-integrated concentrations in several important biospheric comportments. But only a few models, all of them with a 'dynamical' structure, fitted the daily behavior with the reasonable agreement. The dynamical structure of the five most successful models at predicting for Caesium 137 (CIRCLE, ECOSYS, PATHWAY, PRYMA and RAGTIME) shows some common patterns that may be relevant for a better modelling of nuclear accident scenarios. (author)

  10. Right ventricular ejection fraction - comparison of various angiographic and radionuclide approaches

    International Nuclear Information System (INIS)

    Schicha, H.; Tebbe, U.; Voth, E.; Sciagra, R.; Schultz, W.; Neuhaus, G.; Goettingen Univ.

    1987-01-01

    In 21 patients with various heart diseases RVEF was measured angiographically and by radionuclide ventriculography. Using biplane angiocardiography evaluation was performed by 7 different methods (Simpson's rule, Dogde, Arcilla, Ferlinz, Duebel). Using equilibrium RNV, evaluation was performed by 9 modifications of analysis. Problems were evident to separate the right atrium from the ventricle and to define the site of the pulmonary valve. The results show that when using the various methods of angiography considerable variations of the absolute volumes occur, but least so with RVEF. When using RNV with one single enddiastolic ROI, the RVEF was much too low. By means of the enddiastolic/endsystolic Double-ROI-method a good agreement with angiography was found, with correlation coefficients up to r=0.85. There was only a minor effect of background correction. (orig.) [de

  11. Interlaboratory comparison: Radionuclides in Irish sea water. IAEA-443

    International Nuclear Information System (INIS)

    2009-01-01

    comparisons, production of Reference Materials and Certified Reference Materials, and training. More than 40 Reference Materials have been produced, which include a wide range of marine sample matrices and radionuclide concentrations. As part of these activities, a new interlaboratory comparison was organized to provide the participating laboratories with the possibility of testing the performance of their analytical methods on a seawater sample with elevated radionuclide levels due to discharges from a nuclear facility. The material was designed for the analysis of anthropogenic and natural radionuclides in sea water. It is expected that the sample, after successful certification, will be issued as a Certified Reference Material for radionuclides in sea water

  12. A comparison of some radionuclide contents in environmental samples

    International Nuclear Information System (INIS)

    Shiraishi, Kunio; Muramatsu, Yasuyuki; Nakajima, Toshiyuki; Yamamoto, Masayoshi; Los, I.P.; Kamarikov, I.Yu.; Buzinny, M.G.

    1992-01-01

    Global contamination by radionuclides was likely induced through the Chernobyl nuclear accident in 1986. Environmental samples such as fish, milk, total diet samples etc., collected in Kiev, in the vicinity of Chernobyl, and Mito city, Japan, were analyzed for six selected radionuclides. After samples were dry-ashed, radioactivities of Cs-137, Cs-134, K-40, Co-60, and Mn-54 were determined by gamma-ray spectroscopy with a germanium detector. Strontium-90 was determined by low-background beta-spectrometry after chemical separations by fuming nitric acid. Concentrations of radioactivities in the Kiev samples, in the vicinity of the Chernobyl, are shown below. For comparison, values obtained in Japan, including literature values, are shown in parentheses. Radioactivities in airborne dust were: Sr-90, 63 mBq/m 3 (0.001-0.1); Cs-137, 26 mBg/m 3 (0.001-1); Cs-134, 4 mBq/m 3 ; Co-60, 4 mBq/m 3 ; Mn-54, 2 mBq/m 3 . Radioactivities of milk were as follows; Sr-90, 0.25-1.2 Bq/liter (0.01-0.1); Cs-137, 6-77 Bq/liter (0.01-1); Cs-134, 2-8 Bq/liter. Radioactivities of Sr-90 and Cs-137 for fish (carp), were found to be 3-75 Bq/kg-fresh (0.76-0.98) and 46-2130 Bq/kg-fresh (<0.8), respectively. It was observed that the daily intake of Sr-90 and Cs-137 were 0.25 Bq (0.1) and 0.43 Bq (0.1) per person, respectively. Due to the small number of samples analyzed it is premature to draw a firm conclusion from this study. However, the levels of radionuclides in environmental samples were found to differ between Kiev and Mito with wide ranges depending on the samples. (author)

  13. Radionuclide cardiography in medical practice

    International Nuclear Information System (INIS)

    Strangfeld, D.; Mohnike, W.; Schmidt, J.; Heine, H.; Correns, H.J.

    1986-01-01

    This publication is a compendium on all aspects of radionuclide diagnostics concerning cardiovascular system diseases. Starting with introductory remarks on the control of cardiovascular diseases the contribution of radionuclide cardiology to functional cardiovascular diagnostics as well as pathophysiological and pathobiochemical aspects of radiocardiography are outlined. Radiopharmaceuticals used in radiocardiography, physical and technical problems in application of radionuclides and their measuring techniques are discussed. In individual chapters radionuclide ventriculography, myocardial scintiscanning, circulatory diagnostics, radionuclide diagnostics of arterial hypertension, of thrombosis and in vitro diagnostics of thrombophilia are treated in the framework of clinical medicine

  14. Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI

    DEFF Research Database (Denmark)

    Kjaer, Andreas; Lebech, Anne-Mette; Hesse, Birger

    2005-01-01

    for evaluation of right-sided cardiac function. The aim of our study was to compare the agreement between these methods when measuring right-sided cardiac function. METHODS: Twenty-four healthy volunteers were included. Mean age was 44 years (range: 25-60) and 29% were females. All participants had FP, GBPS...

  15. Radionuclide ventriculography during rest and exercise: normal values

    International Nuclear Information System (INIS)

    Ludwig, E.B.; Marroni, B.J.; Achutti, A.C.; Anselmi, O.E.; Rabin, M.

    1983-01-01

    Twenty young volunteers of both sexes were examined by radioisotopic techniques to establish the normal range of ventricular function at rest and the response to a stress test (systolic arterious pressure X cardiac frequency > 25000). (M.A.C.) [pt

  16. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  17. Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography

    International Nuclear Information System (INIS)

    Malave, S.R.; Neiman, H.L.; Spies, S.M.; Cisternino, S.J.; Adamo, G.

    1980-01-01

    Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function

  18. Comparison of radiographic and radionuclide skeletal surveys in battered children

    International Nuclear Information System (INIS)

    Pickett, W.J.; Faleski, E.J.; Chacko, A.; Jarrett, R.V.

    1983-01-01

    A review of 13 cases of suspected child abuse in which radionuclide (RN) scans, radiographic skeletal surveys, and sufficient follow-up were available showed that the RN scans were insensitive, even though fractures were more than 48 hours old at the time of the scan. Frequently missed lesions included skull and extremity fractures. Furthermore, soft tissue and visceral abnormalities that were identified on radiographic examination went undetected on RN scan. We conclude that, although the RN scan may augment the radiographic examination, it should not be used alone to screen for the battered child

  19. Comparison of models of radionuclide migration in food chains

    International Nuclear Information System (INIS)

    Hanusik, V.; Mitro, A.; Chorvat, D.

    1985-01-01

    Two models are compared used for describing the transfer of radioactive substances to man through food chains: the model used in US NRC Regulatory Guide 1.109 and that used in Interatomehnergo NTD No. 38.220.56-81. The models are compared with regard to the approach to model construction, with regard to mathematical expressions and recommended values of parameters. The comparative calculations show that with the use of the recommended values the contribution of direct contamination is prevalent in both models. The concentration of radioactive substances in selected products calculated for indirect contamination using the NRC method is more conservative. For direct and total contamination the NRC method provides higher values of concentrations in the leaf and non-leaf vegetables (cabbage, potatoes, cucumbers) than the NTD method. Concentrations in non-leaf vegetables are higher than in wheat for 4 nuclides only and in meat and milk for 13 radionuclides of the considered set of 22 radionuclides. Substitution of the recommended values of the parameters of the NRC model with recommended values of the corresponding parameters of the NTD model will reduce total concentrations in products as against initial results of the two studied models. (author)

  20. Worldwide Laboratory Comparison on the Determination of Radionuclides in IAEA-446 Baltic Sea Seaweed (Fucus vesiculosus)

    International Nuclear Information System (INIS)

    2013-01-01

    The Radiometrics Laboratory of the IAEA Environment Laboratories in Monaco has been providing quality products and services for the past forty years, including the organization of interlaboratory comparisons, the production of reference and certified reference materials and the provision of training. More than 45 reference materials have been produced, including a wide range of marine sample matrices and radionuclide concentrations. As part of these activities, a new interlaboratory comparison was organized to provide participating laboratories with the opportunity to test the performance of their analytical methods on a seaweed sample with elevated radionuclide levels due to the effects of the Chernobyl accident on the Baltic Sea region. The material used in the analysis of anthropogenic and natural radionuclides in seaweed was the bladder wrack (Fucus vesiculosus). It is expected that the sample, after successful certification, will be issued as a certified reference material for analysing radionuclides in seaweed. The participating laboratories were informed that the IAEA publication would contain a list of the laboratories and the results and descriptions of the interlaboratory comparisons, but that the results would not be attributed to individual laboratories

  1. Worldwide Laboratory Comparison on the Determination of Radionuclides in IAEA-446 Baltic Sea Seaweed (Fucus vesiculosus)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-15

    The Radiometrics Laboratory of the IAEA Environment Laboratories in Monaco has been providing quality products and services for the past forty years, including the organization of interlaboratory comparisons, the production of reference and certified reference materials and the provision of training. More than 45 reference materials have been produced, including a wide range of marine sample matrices and radionuclide concentrations. As part of these activities, a new interlaboratory comparison was organized to provide participating laboratories with the opportunity to test the performance of their analytical methods on a seaweed sample with elevated radionuclide levels due to the effects of the Chernobyl accident on the Baltic Sea region. The material used in the analysis of anthropogenic and natural radionuclides in seaweed was the bladder wrack (Fucus vesiculosus). It is expected that the sample, after successful certification, will be issued as a certified reference material for analysing radionuclides in seaweed. The participating laboratories were informed that the IAEA publication would contain a list of the laboratories and the results and descriptions of the interlaboratory comparisons, but that the results would not be attributed to individual laboratories.

  2. Quality control of radionuclide calibrators: Interlaboratory comparison of thallium-201

    International Nuclear Information System (INIS)

    Debertin, K.

    1985-01-01

    After 131 I and sup(99m)Tc comparisons in 1982 and 1983, the Physikalisch-Technische Bundesanstalt (PTB) in cooperation with the firm Amersham-Buchler organized a further comparison in October 1984 in order to investigate the accuracy of activity measurements in nuclear medicine. 48 hospitals or institutes participated in this 201 TI comparison. The wast majority of the reported results agreed with the PTB-value to within 10%, however in 5 cases deviations amounted to more than 20%. (orig.) [de

  3. Radionuclide ventriculographic evaluation of exercised left ventricular performance in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Fujii, Yusuke; Hara, Fumio

    1991-01-01

    Radionuclide ventriculography was made in 49 asymptomatic diabetic patients, aged 30∼70 years, to investigate cardiac function. Comparisons were made with 33 age- and sex-matched non-diabetic controls. Radionuclide ventriculography was performed at rest and during dynamic exercise by multigraded, supine bicycle ergometer. The resting left ventricular ejection fractions were similar between the diabetic patients and control subjects. No significant rise in the left ventricular ejection fractions during dynamic exercise was observed in the diabetic patients [58.4±9.8% (mean±SD) to 60.3±9.9]. In the control subjects, the left ventricular ejection fractions increased during dynamic exercise [59.3±8.4 to 63.0±11.4 (p -1 ) vs -2.66±0.52] and during dynamic exercise [-3.25±0.74 vs -3.23±0.90]. Time to end-systole were similar in both groups at rest [315±42 (ms) vs 309±42] and during dynamic exercise [258±37 vs 262±37]. The resting peak filling rates were similar in both groups [2.27±0.62 (s -1 ) vs 2.45±0.58], and the peak filling rates increased (p 1c in the diabetic patients. These results suggest that diabetic patients have less cardiac reserved performance. (author)

  4. Comparison of marine dispersion model predictions with environmental radionuclide concentrations

    International Nuclear Information System (INIS)

    Johnson, C.E.; McKay, W.A.

    1988-01-01

    The comparison of marine dispersion model results with measurements is an essential part of model development and testing. The results from two residual flow models are compared with seawater concentrations, and in one case with concentrations measured in marine molluscs. For areas with short turnover times, seawater concentrations respond rapidly to variations in discharge rate and marine currents. These variations are difficult to model, and comparison with concentrations in marine animals provides an alternative and complementary technique for model validation with the advantages that the measurements reflect the mean conditions and frequently form a useful time series. (author)

  5. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  6. Do we need ventriculography in the era of computed tomography

    International Nuclear Information System (INIS)

    Wende, S.; Kishikawa, T.; Huewel, N.; Kazner, E.; Grumme, T.; Lanksch, W.

    1982-01-01

    The question is posed whether in the investigation of intracranial tumors, particularly in the posterior cranial fossa, CT and/or ventriculography should be practiced. We investigated 134 patients (93 were children up to the age of 14 years), all of whom had both computed tomography and ventriculography. The results clearly demonstrate the superiority of CT compared with centriculography. Ventriculography is a surgical intervention with risk for the patient; side effects may occur and serious complications can sometimes arise. Modern CT is producing pictures of high quality which are entirely sufficient for neurosurgical intervention. Very rarely does additional angiography have to be performed. The diagnosis of intracrenial tumor can be fully established by CT and ventriculogrphy is no longer necessary. (orig.)

  7. Results of an international comparison for the determination of radionuclide activity in bilberry material

    International Nuclear Information System (INIS)

    Wätjen, U.; Altzitzoglou, T.; Ceccatelli, A.; Dikmen, H.; Emteborg, H.; Ferreux, L.; Frechou, C.; La Rosa, J.; Luca, A.; Moreno, Y.; Oropesa, P.; Pierre, S.; Schmiedel, M.

    2012-01-01

    Radioactivity found in wild food products has assumed greater importance when assessing the total exposure of the population. For this reason, IRMM has been developing a reference material for the activity concentration of three radionuclides in bilberry samples. In order to characterise this new material, a CCRI(II) supplementary comparison was organised. The difficulties encountered in this comparison are discussed, in particular the efficiency calibration for volume sources of gamma-ray emitters, and comparison reference values for 137 Cs and 40 K are calculated. - Highlights: ► CCRI(II) supplementary comparison for Cs-137 and K-40 in bilberry matrix completed. ► Fundamentally different methods used to establish link to SI traceable standards and SIR. ► Variation of results higher than in CCRI(II) key comparisons. ► Comparison reference values will be robust property values of IRMM reference material. ► Certified reference material for radioactivity in food developed.

  8. An inter-lab comparison determination of radionuclides in soil samples by γ-apectrometry

    International Nuclear Information System (INIS)

    Pan Jingquan; Zhang Shurong; Xu Cuihua

    1986-01-01

    The results of an inter-lab comparison of quantitative determination of radionuclides in two soil samples and in an imitated one used as standard reference material by direct γ-spectrometry are presented and discussed. The methods of preparation of the three samples, its homogeneity and the procedures used in this inter-lab comparison are also described. Fifteen laboratories in China participated in this program. The contents of main radionuclides in the samples were estimated by statistical treatment of the reproted data. More than 91% of these laboratories obtained mean values with relative standard deviation below 20%, and in 88% of them the average values we e within the range of the standard reference values with deviation less than 10%. Statistical analysis showed that random error might be underestimated or systematic error might exist in a few laboratories

  9. EANM/ESC guidelines for radionuclide imaging of cardiac function

    DEFF Research Database (Denmark)

    Hesse, B.; Lindhardt, T.B.; Acampa, W.

    2008-01-01

    radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes...

  10. Radionuclide toxicity

    International Nuclear Information System (INIS)

    Galle, P.

    1982-01-01

    The aim of this symposium was to review the radionuclide toxicity problems. Five topics were discussed: (1) natural and artificial radionuclides (origin, presence or emission in the environment, human irradiation); (2) environmental behaviour of radionuclides and transfer to man; (3) metabolism and toxicity of radionuclides (radioiodine, strontium, rare gas released from nuclear power plants, ruthenium-activation metals, rare earths, tritium, carbon 14, plutonium, americium, curium and einsteinium, neptunium, californium, uranium) cancerogenous effects of radon 222 and of its danghter products; (4) comparison of the hazards of various types of energy; (5) human epidemiology of radionuclide toxicity (bone cancer induction by radium, lung cancer induction by radon daughter products, liver cancer and leukaemia following the use of Thorotrast, thyroid cancer; other site of cancer induction by radionuclides) [fr

  11. Comparison of US/FRG accident condition models for HTGR fuel failure and radionuclide release

    International Nuclear Information System (INIS)

    Verfondern, K.

    1991-03-01

    The objective was to compare calculation models used in safety analyses in the US and FRG which describe fission product release behavior from TRISO coated fuel particles under core heatup accident conditions. The frist step performed is the qualitative comparison of both sides' fuel failure and release models in order to identify differences and similarities in modeling assumptions and inputs. Assumptions of possible particle failure mechanisms under accident conditions (SiC degradation, pressure vessel) are principally the same on both sides though they are used in different modeling approaches. The characterization of a standard (= intact) coated particle to be of non-releasing (GA) or possibly releasing (KFA/ISF) type is one of the major qualitative differences. Similar models are used regarding radionuclide release from exposed particle kernels. In a second step, a quantitative comparison of the calculation models was made by assessing a benchmark problem predicting particle failure and radionuclide release under MHTGR conduction cooldown accident conditions. Calculations with each side's reference method have come to almost the same failure fractions after 250 hours for the core region with maximum core heatup temperature despite the different modeling approaches of SORS and PANAMA-I. The comparison of the results of particle failure obtained with the Integrated Failure and Release Model for Standard Particles and its revision provides a 'verification' of these models in this sense that the codes (SORS and PANAMA-II, and -III, respectively) which were independently developed lead to very good agreement in the predictions. (orig./HP) [de

  12. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  13. A comparison of measured radionuclide release rates from Three Mile Island Unit-2 core debris for different oxygen chemical potentials

    International Nuclear Information System (INIS)

    Baston, V.F.; Hofstetter, K.J.; Ryan, R.F.

    1987-01-01

    Chemical and radiochemical analyses of reactor coolant samples taken during defueling of the Three Mile Island Unit-2 (TMI-2) reactor provide relevant data to assist in understanding the solution chemistry of the radionuclides retained within the TMI-2 reactor coolant system. Hydrogen peroxide was added to various plant systems to provide disinfection for microbial contamination and has provided the opportunity to observe radionuclide release under different oxygen chemical potentials. A comparison of the radionuclide release rates with and without hydrogen peroxide has been made for these separate but related cases, i.e., the fuel transfer canal and connecting spent-fuel pool A with the TMI-2 reactor plenum in the fuel transfer canal, core debris grab sample laboratory experiments, and the reactor vessel fluid and associated core debris. Correlation and comparison of these data indicate a physical parameter dependence (surface-to-volume ratio) affecting all radionuclide release; however, selected radionuclides also demonstrate a chemical dependence release under the different oxygen chemical potentials. Chemical and radiochemical analyses of reactor coolant samples taken during defueling of the Three Mile Island Unit-2 (TMI-2) reactor provide relevant data to assist in understanding the solution chemistry of the radionuclides retained within the TMI-2 reactor coolant system

  14. Modelling the behaviour of long-lived radionuclides in the Irish Sea - comparison of model predictions with field observations

    International Nuclear Information System (INIS)

    Kershaw, P.J.; Pentreath, R.J.; Gurbutt, P.A.; Woodhead, D.S.; Durance, J.A.; Camplin, W.C.

    1988-01-01

    A multi-compartmental box model of the Irish Sea has been developed to predict the distribution and radiological consequences of radionuclides discharged from the Sellafield reprocessing plant. The box structure was based on observations of radionuclide distributions in the sea bed and the water circulation was generated from extensive time-series data on 137 Cs concentrations in seawater. Measurements of naturally-occurring nuclides provided both data on the extent and rate of these processes and a means to validate the model assumptions. The model structure is briefly outlined, comparisons are made between model predictions and field observation, and some of the difficulties in making such comparisons are discussed. (author)

  15. Comparison of radionuclide levels in soil, sagebrush, plant litter, cryptogams, and small mammals

    International Nuclear Information System (INIS)

    Landeen, D.S.

    1994-09-01

    Soil, sagebrush, plant litter, cryptogam, and small mammal samples were collected and analyzed for cesium-137, strontium-90, plutonium-238, plutonium 239/240, technetium-99, and iodine-129 from 1981 to 1986 at the US Department of Energy Hanford Site in southeastern Washington State as part of site characterization and environmental monitoring activities. Samples were collected on the 200 Areas Plateau, downwind from ongoing waste management activities. Plant litter, cryptogams, and small mammals are media that are not routinely utilized in monitoring or characterization efforts for determination of radionuclide concentrations. Studies at Hanford, other US Department of Energy sites, and in eastern Europe have indicated that plant litter and cryptogams may serve as effective ''natural'' monitors of air quality. Plant litter in this study consists of fallen leaves from sagebrush and ''cryptogams'' describes that portion of the soil crust composed of mosses, lichens, algae, and fungi. Comparisons of cesium-137 and strontium-90 concentrations in the soil, sagebrush, litter, and cryptogams revealed significantly higher (p<0.05) levels in plant litter and cryptogams. Technetium-99 values were the highest in sagebrush and litter. Plutonium-238 and 239/40 and iodine-129 concentrations never exceeded 0.8 pCi/gm in all media. No evidence of any significant amounts of any radionuclides being incorporated into the small mammal community was discovered. The data indicate that plant litter and cryptogams may be better, indicators of environmental quality than soil or vegetation samples. Augmenting a monitoring program with samples of litter and cryptogams may provide a more accurate representation of radionuclide environmental uptake and/or contamination levels in surrounding ecosystems. The results of this study may be applied directly to other radioecological monitoring conducted at other nuclear sites and to the monitoring of other pollutants

  16. Comparisons of activity measurements in nuclear medicine with radionuclide calibrators in the Czech Republic

    International Nuclear Information System (INIS)

    Olsovcova, V.; Dryak, P.

    2002-01-01

    Activity measurements in nuclear medicine using so called 'radionuclide calibrators' or 'activimeters' have been performed for several decades and their reliability has varied. This paper presents comparison of data obtained in annual accuracy checks during the last decade in the Czech Republic, which were carried out by Czech Metrological Institute, Inspectorate for Ionizing Radiation (CMI IIR). Since there is a legal requirement of annual accuracy checks, all of 48 Nuclear Medicine departments in the Czech Republic have participated in the survey. During the last decade the system of accuracy checks has undergone a gradual development. In the initial system one radionuclide sample out of the offer-list was prepared and its activity measured by 4πγ reference chamber. The sample was then sent to the participants, who measured for them an unknown activity and filled out the questionnaire. Later the answers were evaluated in CMI IIR. This system was found unsatisfactory, mostly because of the long time intervals between the measurement and evaluation of results. Therefore, a different system, under which each participant can choose for the accuracy check all the radionuclides from the offered set, was first tried in the year 2000. The offered set is being gradually enlarged, so in 2001 it consisted of four nuclides 99m Tc, 131 I, 67 Ga and 201 Tl. Solution samples (5 ml volume in 10 ml standard serum bottle - the most common in the CR) are prepared in advance from all the nuclides except for 99m Tc and measured with 4πγ chamber to obtain a conventionally true value of activity. In case of 99m Tc is as the true value considered the activity measured with CMI's activimeter whose calibration is periodically compared with 4πγ chamber measurements

  17. Evaluation of ventriculography as a supplement to computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nakstad, P.; Sortland, O.; Hovind, K.

    1982-04-01

    The diagnostic value of ventriculography (VGR) as a supplement to computed tomography (CT) is evaluated in 42 patients. CT was slightly superior for diagnosing expanding lesions and could tell more about the size and nature of the processes in this selected material which includes only lesions adjacent to the ventricular system. VGR yielded more information about the attachment of a tumor to the wall, floor, or roof of the ventricles. Stenosis or occlusion of the Sylvian aqueduct, communicating hydrocephalus, and basal adhesive arachnoiditis were diagnosed by VGR, while the correct diagnosis could be suggested only by CT in these cases.

  18. Radionuclide diagnostics of right ventricle

    International Nuclear Information System (INIS)

    Zaorska-Rajca, J.

    1993-01-01

    Difficulties in evaluating the right ventricle function motivate to making research into new non-invasive methods. Four radionuclide methods that are used to access the right ventricle have been discussed in this paper: first-pass angiocardiography, gated equilibrium ventriculography with red blood cells labelled in vivo technetium- 99 Tc, ventriculography with radioactive xenon 133 and a computerized single probe. Advantages and disadvantages of using each method have been discussed. RNV 99m Tc method has been recognized as the best one to evaluate RV function. Results of the right ventricle assessment in patients have been discussed in the following clinical groups: chronic cor pulmonale (CP), chronic lung disease without pulmonary arterial hypertension (LD), coronary artery disease (CAD), in patients after infarction (IMA and IMi), dilated cardiomyopathy (KZ) and valvular heart diseases (Wm and Wa). Abnormals in right ventricle function occur with different intensity in all groups, although they no specificity. The highest abnormality occurs in patients with KZ, CP, IMi and Wm, the lowest one - in patients with CAD. Abnormalities are higher in patients with congestive heart failure. In most pathological groups the right ventricle dysfunction is connected with the left ventricle insufficiency. The interdependence between the dysfunction of both ventricles is differs in particular diseases. Assessment of right ventricle function with radionuclide methods plays an important role in diagnosis and control therapy of cardiopulmonary diseases. (author). 385 refs, 48 figs, 6 tabs

  19. Radionuclide migration in ground water at a low-level waste disposal site: a comparison of predicted radionuclide transport modeling versus field observations

    International Nuclear Information System (INIS)

    Bergeron, M.P.; Robertson, D.E.; Champ, D.R.; Killey, R.W.D.; Moltyaner, G.L.

    1987-01-01

    At the Chalk River Nuclear Laboratories (CRNL), in Ontario, Canada, a number of LLW shallow-land burial facilities have existed for 25-30 years. These facilities are useful for testing the concept of site modelability. In 1984, CRNL and the Pacific Northwest Laboratory (PNL) established a cooperative research program to examine two disposal sites having plumes of slightly contaminated ground water for study. This report addresses the LLW Nitrate Disposal Pit site, which received liquid wastes containing approximately 1000-1500 curies of mixed fission products during 1953-54. The objective of this study is to test the regulatory requirement that a site be modeled and to use the Nitrate Disposal Pit site as a field site for testing the reliability of models in predicting radionuclide movement in ground water. The study plan was to approach this site as though it were to be licensed under the requirements of 10 CFR 61. Under the assumption that little was known about this site, a characterization plan was prepared describing the geologic, hydrologic, and geochemical information needed to assess site performance. After completion of the plan, site data generated by CRNL were selected to fill the plan data requirements. This paper describes the site hydrogeology, modeling of ground water flow, the comparison of observed and predicted radionuclide movement, and summarizes the conclusions and recommendations. 3 references, 10 figures

  20. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  1. Radionuclide determination of right and left ventricular stroke volumes

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wei Feng; Roubin, G S; Choong, C Y.P.; Harris, P J; Flether, P J; Kelly, D T; Uren, R F; Hutton, B F

    1985-03-01

    The relationship between radionuclide and thermodilution measurement of stroke volumes (SV) was investigated in 30 patients without valvular regurgitation or intracardiac shunt (group A) at rest and during exercise. Both attenuated radionuclide right ventricular (RV) and left ventricular (LV) SV measurements correlated well with the SV determined by the thermodilution method (r = 0.87 and r = 0.93, all P < 0.001). The reliability of the radionuclide method to estimate SV was evaluated prospectively in two additional groups of patients. In 11 patients without valvular regurgitation or intracardiac shunt (group B) the radionuclide RVSV and LVSV closely approximated to thermodilution SV at rest and during exercise. In 15 patients with aortic regurgitation (group C) the radionuclide stroke volume ratio correlated well with the angiographic regurgitant fraction. Thus, both RVSV and LVSV and the severity of aortic regurgitation can be reliably measured with gated radionuclide ventriculography.

  2. Comparison of dye dilution method to radionuclide techniques for cardiac output determination in dogs

    International Nuclear Information System (INIS)

    Eng, S.S.; Robayo, J.R.; Porter, W.; Smith, R.E.

    1980-01-01

    A study was undertaken to identify the most accurate /sup 99m/Tc-labeled radiopharmaceutical and to determine the accuracy of a noninvasive radionuclide technique or cardiac output determinations. Phase I employed sodium pertechnetate, stannous pyrophosphate with sodium pertechnetate, /sup 99m/Tc red blood cells, and /sup 99m/Tc human serum albumin as radionuclide tracers. Cardiac output was determined by the dye dilution method and then by the invasive radionuclide technique. A pairied t test and regression analysis indicated that /sup 99m/Tc human serum albumin was the most accurate radiopharmaceutical for cardiac output determinations, and the results compared favorably to those obtained by the dye dilution method. In Phase II, /sup 99m/Tc human serum albumin was used as the radionuclide tracer for cardiac output determinations with the noninvasive technique. The results compared favorably to those obtained by the dye dilution method

  3. Comparison of Different Internal Dosimetry Systems for Selected Radionuclides Important to Nuclear Power Production

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, Richard Wayne [ORNL; Eckerman, Keith F [ORNL; Manger, Ryan P [ORNL

    2013-08-01

    This report compares three different radiation dosimetry systems currently applied by various U.S. Federal agencies and dose estimates based on these three dosimetry systems for a set of radionuclides often identified in power reactor effluents. These dosimetry systems were developed and applied by the International Commission on Radiological Protection at different times over the past six decades. Two primary modes of intake of radionuclides are addressed: ingestion in drinking water and inhalation. Estimated doses to individual organs and to the whole body based on each dosimetry system are compared for each of four age groups: infant, child, teenager, and adult. Substantial differences between dosimetry systems in estimated dose per unit intake are found for some individual radionuclides, but differences in estimated dose per unit intake generally are modest for mixtures of radionuclides typically found in nuclear power plant effluents.

  4. Inter-comparison of dynamic models for radionuclide transfer to marine biota in a Fukushima accident scenario

    Energy Technology Data Exchange (ETDEWEB)

    Vives i Batlle, J.; Beresford, N. A.; Beaugelin-Seiller, K.; Bezhenar, R.; Brown, J.; Cheng, J. -J.; Ćujić, M.; Dragović, S.; Duffa, C.; Fiévet, B.; Hosseini, A.; Jung, K. T.; Kamboj, S.; Keum, D. -K.; Kryshev, A.; LePoire, D.; Maderich, V.; Min, B. -I.; Periáñez, R.; Sazykina, T.; Suh, K. -S.; Yu, C.; Wang, C.; Heling, R.

    2016-03-01

    We report an inter-comparison of eight models designed to predict the radiological exposure of radionuclides in marine biota. The models were required to simulate dynamically the uptake and turnover of radionuclides by marine organisms. Model predictions of radionuclide uptake and turnover using kinetic calculations based on biological half-life (TB1/2) and/or more complex metabolic modelling approaches were used to predict activity concentrations and, consequently, dose rates of 90Sr, 131I and 137Cs to fish, crustaceans, macroalgae and molluscs under circumstances where the water concentrations are changing with time. For comparison, the ERICA Tool, a model commonly used in environmental assessment, and which uses equilibrium concentration ratios, was also used. As input to the models we used hydrodynamic forecasts of water and sediment activity concentrations using a simulated scenario reflecting the Fukushima accident releases. Although model variability is important, the intercomparison gives logical results, in that the dynamic models predict consistently a pattern of delayed rise of activity concentration in biota and slow decline instead of the instantaneous equilibrium with the activity concentration in seawater predicted by the ERICA Tool. The differences between ERICA and the dynamic models increase the shorter the TB1/2 becomes; however, there is significant variability between models, underpinned by parameter and methodological differences between them. The need to validate the dynamic models used in this intercomparison has been highlighted, particularly in regards to optimisation of the model biokinetic parameters.

  5. Value of radionuclide angiocardiography for determination of left ventricular volume in patients with valvular heart diseases (preliminary report)

    International Nuclear Information System (INIS)

    Madeja, G.; Konieczna, S.; Gosiewska-Marcinkowska, E.; Leszek, P.

    1991-01-01

    In 15 patients with mitral valve defect and 10 patients with aortic valve defect, left ventricular end-diastolic and end-systolic volumes were determined by gated radionuclide angiography. The results were compared with contrast ventriculography. The correlation coefficient between the two methods was much lower in cases of mitral valve diseases. (author). 1 tab

  6. Assessment of poststress left ventricular ejection fraction by gated SPECT: comparison with equilibrium radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Acampa, Wanda; Liuzzi, Raffaele; De Luca, Serena; Capasso, Enza; Luongo, Luca; Cuocolo, Alberto; Caprio, Maria Grazia; Nicolai, Emanuele; Petretta, Mario

    2010-01-01

    We compared left ventricular (LV) ejection fraction obtained by gated SPECT with that obtained by equilibrium radionuclide angiocardiography in a large cohort of patients. Within 1 week, 514 subjects with suspected or known coronary artery disease underwent same-day stress-rest 99m Tc-sestamibi gated SPECT and radionuclide angiocardiography. For both studies, data were acquired 30 min after completion of exercise and after 3 h rest. In the overall study population, a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.82, p<0.0001) and after stress (r=0.83, p<0.0001). In Bland-Altman analysis, the mean differences in ejection fraction (radionuclide angiocardiography minus gated SPECT) were -0.6% at rest and 1.7% after stress. In subjects with normal perfusion (n=362), a good correlation between ejection fraction measured by gated SPECT and by radionuclide angiocardiography was observed at rest (r=0.72, p<0.0001) and after stress (r=0.70, p<0.0001) and the mean differences in ejection fraction were -0.9% at rest and 1.4% after stress. Also in patients with abnormal perfusion (n=152), a good correlation between the two techniques was observed both at rest (r=0.89, p<0.0001) and after stress (r=0.90, p<0.0001) and the mean differences in ejection fraction were 0.1% at rest and 2.5% after stress. In a large study population, a good agreement was observed in the evaluation of LV ejection fraction between gated SPECT and radionuclide angiocardiography. However, in patients with perfusion abnormalities, a slight underestimation in poststress LV ejection fraction was observed using gated SPECT as compared to equilibrium radionuclide angiocardiography. (orig.)

  7. The analysis of results of comparison test for radionuclides measurement through γ spectrum analysis from 2007 to 2012

    International Nuclear Information System (INIS)

    Wu Jialong; He Jian; Sun Wei; Wang Yun

    2013-01-01

    In order to test the capability of radionuclides measurement through γ spectrum analysis and improve the ability of the technicians by inter-laboratory comparison test, Gansu Center for Disease Prevention and Control participated in the comparison test organized by China Center for Disease Prevention and Control continuously from 2007 to 2012. All of the measured values are within the scope of qualified, and the relative deviation of measured value in the entire comparison tests is range from -16.31% to 11.83%.The results show that the equipment for γ spectrum measurement works normally, the analysis methods used for radioactive nuclide measuring is correct and the data in issued test report is accurate and reliable. The ability of the γ spectrum analysis satisfies the requirements of China Metrology Accreditation and the occupational health technical service. (authors)

  8. Clinical assessment of patients with mitral valve prolapse syndrome using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Ochiai, Masakazu; Shirayama, Takeshi; Otsuki, Katsuichi; Adachi, Haruhiko; Nakagawa, Masao.

    1995-01-01

    Left ventricular performance in patients with mitral valve prolapse syndrome (MVP) was evaluated and compared with that in patients with ischemic heart diseases (IHD), consisting of angina pectoris (AP) and old myocardial infarction (OMI). Left ventricular ejection fraction (LVEF) and peak ejection rate (PER) were used as indices of systolic function. Peak filling rate (PFR), filling fraction in the first third of diastole (1/3FF) and time to peak filling (TPF) were used as indices of diastolic function. At rest, LVEF and PER were significantly larger in the MVP group than those in the OMI group. PFR and TPF were shown better diastolic functions in the MVP group than those in the AP or OMI groups. During stress testing, the LVEF of the MVP group increased during exercise, whereas that of the IHD group decreased gradually to the downward response (exercise-induced ischemia). The PFR of the MVP group curved upward during exercise in contrast with the inconstant response of the IHD group. We conclude that chest pain and various symptom in patients with MVP are unrelated to IHD. (author)

  9. Evaluation of coronary artery disease by functional imaging from equilibrium radionuclide ventriculography

    International Nuclear Information System (INIS)

    He Zuoxiang

    1992-01-01

    Functional imagings were performed in 10 normals, 9 subjects with Non coronary Artery disease (NCAD), 33 CAD patients with documented MI (CAD-WMI) and 20 without MI (CAD-NMI). The sensitivity of LVGEF, LVREF and phase analysis at rest for detecting CAD-WMI was 66.7%, 78.8%, 93.9% respectively. LVGEF, LVREF during exercise for assessing CAD-NMI had the sensitivity of 90%, 80%, respectively, while specificity 90%. Early LVEF decrease, > 10% LVEF decrease and abnormal response at > 7 sectors during exercise were observed in 2 patients with 3 vessel. In conclusion, functional imaging were very useful for detecting CAD and evaluating its extent

  10. The blood-pool technique of radionuclide ventriculography: Data acquisition and evaluation

    International Nuclear Information System (INIS)

    Mueller-Schauenburg, W.

    1986-01-01

    For gated heart studies an in-vitro-labelling of erythrocytes is commonly used. Rest and exercise studies are acquired from LAO. Complementary studies may have different views. Besides the most common direct frame mode acquisition, there are the more flexible list mode and a hybrid mode. Concerning evaluation the ejection fraction is the leading parameter of global ventricular analysis. In local analysis a pixelwise evaluation generates functional images of phases and amplitudes (the Fourier approach developed by the Ulm group) or Noelep's trend images. Special attention has to be paid to the varying cycle length when a sine or cosine fitting (Fourier) is used for curve smoothing or phase and amplitude images. There are two opposed problems: If there are undetected QRS-complexes, the end of the representative cycle will contain early phases of subsequent cycles which must be cut off. In the case of really varying cycle length, the last images of the representative cycle must be corrected for acquisition time per frame. The total count curve may help to discriminate both cases and supplies suitable correction factors in the latter case. (orig.) [de

  11. An attempt to evaluate pulmonary hypertension by phase analysis of radionuclide ventriculography

    International Nuclear Information System (INIS)

    Masuoka, Takeshi; Toyama, Hinako; Ajisaka, Ryuuichi

    1988-01-01

    Using phase analysis derived from the gated blood pool imaging, the pattern of right ventricular regional contraction was examined in 5 patients with pulmonary hypertension who showed 30 mmHg of pulmonary arterial systolic pressure and 20 mmHg or more of mean pulmonary arterial pressure. All of the patients had markedly delayed phase in contraction of right ventricular outflow tract. Pulmonary arterial pressure positively correlated with both the proportion of delayed phase area to the whole right ventricle and mean phase difference between the right and left ventricles. The results suggest the usefulness of phase analysis in the non-invasive evaluation of incease in overloading of right ventricular pressure. (Namekawa, K)

  12. Comparison of radionuclide scans with computer-assisted tomography in diagnosis of intracranial disease

    International Nuclear Information System (INIS)

    Clifford, J.R.; Connolly, E.S.; Voorhies, R.M.

    1976-01-01

    Radionuclide brain scans were compared with computer-assisted tomography (CAT) for the diagnosis of intracranial disorders in 297 patients. The diagnosis was confirmed in 281 patients who formed the population for the study. The radionuclide scan was false positive for 12 patients (3.9 percent) and false negative for eight (2.6 percent). The CAT was false positive for three patients (1 percent) and false negative for one (0.3 percent). In the 133 patients in whom both tests were negative, no evidence of central nervous system pathology has been found during the 6 to 18 month follow-up. Brain tumors and intracerebral hemorrhage are more readily detectable with CAT

  13. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  14. Radionuclides and heavy metal contents in phosphogypsum samples in comparison to cerrado soils

    Energy Technology Data Exchange (ETDEWEB)

    Jacomino, Vanusa Maria Feliciano; Oliveira, Kerley Alberto Pereira de, E-mail: vmfj@cdtn.b, E-mail: kapo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Taddei, Maria Helena Tirollo; Nascimento, Marcos Roberto Lopes, E-mail: mhtaddei@cnen.gov.b, E-mail: pmarcos@cnen.gov.b [Laboratorio de Pocos de Caldas (LAPOC/CNEN-MG), MG (Brazil); Siqueira, Maria Celia, E-mail: mc.ufscar@gmail.co [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil). Dept. de Quimica; Carneiro, Maria Eleonora Deschamps Pires, E-mail: eleonora.deschamps@meioambiente.mg.gov.b [Fundacao Estadual do Meio Ambiente (FEAM), Belo Horizonte, MG (Brazil). Gestao de Residuos Solidos; Silva, David Faria da; Mello, Jaime Wilson Vargas de, E-mail: davidf.agro@hotmail.co, E-mail: jwvmello@ufv.b [Universidade Federal de Vicosa (UFV), MG (Brazil). Dept. de Solos

    2009-09-15

    Phosphogypsum (PG) or agricultural gypsum, a solid waste from the phosphate fertilizer industry, is used as soil amendment, especially on soils in the Cerrado region, in Brazil. This material may however contain natural radionuclides and metals which can be transferred to soils, plants and water sources. This paper presents and discusses the results of physical and chemical analyses that characterized samples of PG and compares them to the results found in two typical soils of the Cerrado, a clayey and sandy one. These analyses included: solid waste classification, evaluation of organic matter content and of P, K, Ca, Mg, and Al concentrations and of the mineralogical composition. Natural radionuclides and metal concentrations in PG and soil samples were also measured. Phosphogypsum was classified as Class II A - not dangerous, not inert, not corrosive and not reactive. The organic matter content in the soil samples was low and potential acidity high. In the mean, the specific {sup 226}Ra activity in the phosphogypsum samples (252 Bq kg{sup -1}) was below the maximum level recommended by USEPA, which is 370 Bq kg{sup -1} for agricultural use. In addition, this study verified that natural radionuclides and metals concentrations in PG were lower than in the clayey Oxisol of Sete Lagoas, Minas Gerais, Brazil. These results indicated that the application of phosphogypsum as soil amendment in agriculture would not cause a significant impact on the environment. (author)

  15. Radionuclides and heavy metal contents in phosphogypsum samples in comparison to cerrado soils

    International Nuclear Information System (INIS)

    Jacomino, Vanusa Maria Feliciano; Oliveira, Kerley Alberto Pereira de; Taddei, Maria Helena Tirollo; Nascimento, Marcos Roberto Lopes; Siqueira, Maria Celia; Carneiro, Maria Eleonora Deschamps Pires; Silva, David Faria da; Mello, Jaime Wilson Vargas de

    2009-01-01

    Phosphogypsum (PG) or agricultural gypsum, a solid waste from the phosphate fertilizer industry, is used as soil amendment, especially on soils in the Cerrado region, in Brazil. This material may however contain natural radionuclides and metals which can be transferred to soils, plants and water sources. This paper presents and discusses the results of physical and chemical analyses that characterized samples of PG and compares them to the results found in two typical soils of the Cerrado, a clayey and sandy one. These analyses included: solid waste classification, evaluation of organic matter content and of P, K, Ca, Mg, and Al concentrations and of the mineralogical composition. Natural radionuclides and metal concentrations in PG and soil samples were also measured. Phosphogypsum was classified as Class II A - not dangerous, not inert, not corrosive and not reactive. The organic matter content in the soil samples was low and potential acidity high. In the mean, the specific 226 Ra activity in the phosphogypsum samples (252 Bq kg -1 ) was below the maximum level recommended by USEPA, which is 370 Bq kg -1 for agricultural use. In addition, this study verified that natural radionuclides and metals concentrations in PG were lower than in the clayey Oxisol of Sete Lagoas, Minas Gerais, Brazil. These results indicated that the application of phosphogypsum as soil amendment in agriculture would not cause a significant impact on the environment. (author)

  16. Bilateral Comparison CIEMAT-CENTIS-DMR for radionuclide activity measurements; Comparacion Bilateral CIEMAT-CENTIS-DMR de la Medida de Actividad de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Oropesa Verdecia, P.; Garcia-Torano, E.

    2004-07-01

    We present the results of a bilateral comparison of radionuclide activity measurements between the Radionuclide Metrology Department of the Center of Isotopes of Cuba (CENTIS-DMR), and the Ionising Radiation Metrology Laboratory (LMRI) of the Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT) of Spain. The aim of the comparison was to establish the comparability of the measurement instruments and methods used to obtain radioactive reference materials of some gamma-emitting nuclides at CENTIS-DMR. The results revealed that there are no statistically significant differences between the data reported by both laboratories. (Author) 7 refs.

  17. Echocardiography, ventriculography and coronary angiography in patients just recovering from acute myocardial infarction

    International Nuclear Information System (INIS)

    Goetz, S.

    1983-01-01

    Comparative evaluations were carried out on the basis of ventriculography, echocardiography and corornary angiography that would permit to throw some light on the following issues: Can the changes in overall ventricular function occurring in response to the processes in the infarcted zone be visualised by means of M-mode scans. Which degree of accuracy can be achieved, if attempts are made to establish an echocardiographic diagnosis on the basis of M-mode scans in order to confirm regional contractility disorders revealed by ventriculography. (orig./MG) [de

  18. Quantitative radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function

  19. The cardiomyopathy in Friedreich's ataxia: isotopic ventriculography and myocardial imaging with thallium-201

    International Nuclear Information System (INIS)

    Therriault, L.; Lamoureux, G.; Cote, M.; Plourde, G.; Lemieux, B.

    1984-01-01

    Myocardial scanning after the intravenous administration of Thallium 201 was used to evaluate regional myocardial perfusion in 14 patients with Friedreich's ataxia. Isotopic ventriculography was also used to assess left ventricular contractility. Myocardial images in patients with Friedreich's ataxia were found to be precociously abnormal irrespective of the degree of neurological impairment or of the severity of myocardial hypertrophy

  20. Comparison of radionuclide data analysis results of the CTBTO/IDC and the Finnish NDC

    Energy Technology Data Exchange (ETDEWEB)

    Ansaranta, T.; Ala-Heikkilae, J.; Aarnio, P. [Helsinki University of Technology, Espoo (Finland)

    2001-06-01

    The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) is to operate a world-wide radionuclide monitoring network consisting of 80 measuring stations that transmit daily gamma-ray spectra measured from air filter samples to the International Data Centre (IDC). All spectra are analysed automatically and the results are reviewed interactively by an analyst. Quality of the automated analysis has a substantial impact on the reliability and efficiency of the analysis operation. The Finnish National Data Centre (FiNDC) receives the analysis results and raw spectral data from the IDC and performs radionuclide analysis of the spectra using dedicated Finnish software packages. This work evaluates the differences between the analysis results of the IDC and the FiNDC. The results are studied with respect to the spectrum peak finding, fitting and explaining performance. Furthermore, nuclides associated with the peaks are considered, and an effort is made to approximate the number of spurious nuclide identifications. The material of this work consists of representative sets containing 500 to 1500 spectra and their respective analysis result pairs. The spectra were measured by the five certified radionuclide stations and three prototype stations that were operating between August 1, 2000 and March 26, 2001. In the set of 1500 spectra from eight stations, the FiNDC analysis software package was found to detect 4.2 more peaks per spectrum and to explain 5.6 more peaks per spectrum than the IDC software package, which, in turn, left 1.4 more peaks per spectrum unexplained. The median peak explanation percentages of the FiNDC and IDC were 96.7 and 92.3, respectively. The FiNDC analysis software package was found to report 0.7 more spurious nuclides than the IDC analysis software package. When only the CTBTO relevant nuclides were considered, the difference decreased to 0.05. The throughput times involved with the IDC raw measuring data transfer and automatic analysis result

  1. Comparison of radionuclide concentrations in 1956 and 1973 Enewetak beach material

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, N.; Rahon, T.E.; Hirshfield, H.

    1985-02-01

    During the period 1948-1958, approximately 40 nuclear weapons tests were performed on the Enewetak Atoll in the Marshall Islands of the central Pacific Ocean. In 1973, the results of a survey contracted by the US Atomic Energy Commission specified that extensive decontamination of the land areas would be necessary before the people of Enewetak could return to the atoll. During Operation Redwing in 1956, several members of the New York University Departments of Biology and Environmental Medicine visited the atoll and collected water, plankton and beach coral samples to study the distribution of foraminifera among the islands of Enewetak and other nearby atolls. Of the specimens collected, 22 samples of beach material from the highly contaminated northern islands of Enewetak remained intact and were available for study. Analyses of the radionuclide concentrations of these samples have provided interesting information regarding the levels of contamination that existed on Enewetak at that time.

  2. Comparison of one-, two-, and three-dimensional models for mass transport of radionuclides

    International Nuclear Information System (INIS)

    Prickett, T.A.; Voorhees, M.L.; Herzog, B.L.

    1980-02-01

    This technical memorandum compares one-, two-, and three-dimensional models for studying regional mass transport of radionuclides in groundwater associated with deep repository disposal of high-level radioactive wastes. In addition, this report outlines the general conditions for which a one- or two-dimensional model could be used as an alternate to a three-dimensional model analysis. The investigation includes a review of analytical and numerical models in addition to consideration of such conditions as rock and fluid heterogeneity, anisotropy, boundary and initial conditions, and various geometric shapes of repository sources and sinks. Based upon current hydrologic practice, each review is taken separately and discussed to the extent that the researcher can match his problem conditions with the minimum number of model dimensions necessary for an accurate solution

  3. Evaluation of Risk Perception and Risk-Comparison Information Regarding Dietary Radionuclides after the 2011 Fukushima Nuclear Power Plant Accident.

    Science.gov (United States)

    Murakami, Michio; Nakatani, Jun; Oki, Taikan

    2016-01-01

    In the wake of the 2011 Fukushima Daiichi Nuclear Power Station accident, to facilitate evidence-based risk communication we need to understand radiation risk perception and the effectiveness of risk-comparison information. We measured and characterized perceptions of dread risks and unknown risks regarding dietary radionuclides in residents of Fukushima, Tokyo, and Osaka to identify the primary factors among location, evacuation experience, gender, age, employment status, absence/presence of spouse, children and grandchildren, educational background, humanities/science courses, smoking habits, and various types of trustworthy information sources. We then evaluated the effects of these factors and risk-comparison information on multiple outcomes, including subjective and objective understanding, perceived magnitude of risk, perceived accuracy of information, backlash against information, and risk acceptance. We also assessed how risk-comparison information affected these multiple outcomes for people with high risk perception. Online questionnaires were completed by people (n = 9249) aged from 20 to 69 years in the three prefectures approximately 5 years after the accident. We gave each participant one of 15 combinations of numerical risk data and risk-comparison information, including information on standards, smoking-associated risk, and cancer risk, in accordance with Covello's guidelines. Dread-risk perception among Fukushima residents with no experience of evacuation was much lower than that in Osaka residents, whereas evacuees had strikingly higher dread-risk perception, irrespective of whether their evacuation had been compulsory or voluntary. We identified location (distance from the nuclear power station), evacuation experience, and trust of central government as primary factors. Location (including evacuation experience) and trust of central government were significantly associated with the multiple outcomes above. Only information on "cancer risk from

  4. Evaluation of Risk Perception and Risk-Comparison Information Regarding Dietary Radionuclides after the 2011 Fukushima Nuclear Power Plant Accident

    Science.gov (United States)

    Murakami, Michio; Nakatani, Jun; Oki, Taikan

    2016-01-01

    In the wake of the 2011 Fukushima Daiichi Nuclear Power Station accident, to facilitate evidence-based risk communication we need to understand radiation risk perception and the effectiveness of risk-comparison information. We measured and characterized perceptions of dread risks and unknown risks regarding dietary radionuclides in residents of Fukushima, Tokyo, and Osaka to identify the primary factors among location, evacuation experience, gender, age, employment status, absence/presence of spouse, children and grandchildren, educational background, humanities/science courses, smoking habits, and various types of trustworthy information sources. We then evaluated the effects of these factors and risk-comparison information on multiple outcomes, including subjective and objective understanding, perceived magnitude of risk, perceived accuracy of information, backlash against information, and risk acceptance. We also assessed how risk-comparison information affected these multiple outcomes for people with high risk perception. Online questionnaires were completed by people (n = 9249) aged from 20 to 69 years in the three prefectures approximately 5 years after the accident. We gave each participant one of 15 combinations of numerical risk data and risk-comparison information, including information on standards, smoking-associated risk, and cancer risk, in accordance with Covello’s guidelines. Dread-risk perception among Fukushima residents with no experience of evacuation was much lower than that in Osaka residents, whereas evacuees had strikingly higher dread-risk perception, irrespective of whether their evacuation had been compulsory or voluntary. We identified location (distance from the nuclear power station), evacuation experience, and trust of central government as primary factors. Location (including evacuation experience) and trust of central government were significantly associated with the multiple outcomes above. Only information on “cancer risk from

  5. Comparison of the Radionuclides Dispersion at the UAE Barakah Site with that at the ROK Shin-Kori Site - Comparison of the radionuclides dispersion in Barakah site with that in Shin-Kori site

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-yeop; Lee, Kun Jai; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Beeley, Philip A. [Khalifa University of Science, Technology and Research, P.O. Box 127788, Abu Dhabi (United Arab Emirates)

    2014-07-01

    In order to understand the characteristics of atmospheric dispersion of radionuclides in the desert environment of Barakah site in UAE, comparison research with the results of other environments could be an appropriate way to facilitate it. Shin-Kori site is the proper comparison target because same reactor type of APR1400 with that in Barakah site is under construction. Hypothetical accident scenario was considered and accident source term which had been developed in previous research has been applied as releasing source. After reviewing several computation codes, ADMS5 has been selected as an atmospheric dispersion modeling tool which is installing advanced Gaussian plum model and plentiful options. The climate data of both Barakah and Shin-Kori were acquired and the environments of both sites have been simulated considering wind speed, wind direction, temperature, humidity, ground surface roughness and etc. Near field final human doses on the maps have been schematised regarding statistical meteorological data of both sites and dose conversion factors from the publications of ICRP and federal guidance report of EPA. The results of this research are expected to enhance the understanding about differences between two environments which have same reactor type and to improve the comprehension of desert environment of Barakah site as well. Applying different dose conversion factors to Barakah site considering the desert biosphere could be further study to obtain more accurate results. (authors)

  6. Exercise radionuclide ventriculographic study of mitral stenosis before and after percutaneous mirtal valvuloplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Shim, Won Heum; Cho, Seung Yun; Kim, Sung Soon; Lee, Woong Ku; Kim, Myeong Jin; Choe, Kyu Ok [Yonsei University, College of Medicine, Seoul (Korea, Republic of); Park, Seung Jung [Asan Medical Center, College of Medicine, University of Ulsan, Seoul (Korea, Republic of)

    1992-11-15

    We performed radionuclide ventriculography before and within 1 week after percutaneous mirtal valvuloplasty (PMV) to evaluate left ventricular (LV) function in 20 patients (2 meals and 17 females, mean age of 38 {+-} 10 years) who were pure mitral stenosis before PMV and less than grade 1 mirtal regurgitation developed after PMV. 9 out of 20 patients had atrial fibrillation and 3 patients developed a small left-to-right shunt (Qp/Qs < 1.5) after PMV. PMV using double-balloon technique resulted in a increase in mitral valve area (0.9 {+-} 0.3 to 2.1 {+-} 0.8cm{sup 2}, {rho} < 0.001) and in rest cardiac output (4.2 {+-} 1.0 to 4.8 {+-} 1.4 L/min, {rho} < 0.005). And also a decrease in mean mitral gradient (16.2 {+-} 7.0 to 5.2 {+-} 3.0 mmHg, {rho} < 0.001) was noted. Comparisons of LV function by supine bicycle exercise radionuclide ventriculography before and after PMV showed no significant changes in rest LV ejection fraction (LVEF, 55.2 {+-} 9.7 to 56.1 {+-} 11.0%, {rho} > 0.05), maximal exercise LVEF (60.9 {+-} 10.3 to 59.3 {+-} 11.1%, {rho} > 0.05), peak ejection rate (2.02 {+-} 0.58 to 2.15 {+-} 0.60 EDV/ses, {rho} > 0.05), and peak filling rate (1.04 {+-} 0.55 to 1.52 {+-} 0.49 EDV/ses, {rho} > 0.05). However, LV end diastolic volume (LVEDV, -29.3 {+-} 19.0 to +3.3 {+-} 32.9%, {rho} < 0.001), stroke volume (SV,-22.0 {+-} 22.0 to +11.2 {+-} 40.0%, {rho} < 0.001), and cardiac output (CO, 64.6 {+-} 54.0 to 100.4 {+-} 69.7%, {rho} < 0.05) with exercise compared to resting values were significantly increased. We conclude that PMV resulted in a significant increase in LVEDV, SV, and CO with exercise, but decreased LV systolic performance and no improvement in diastolic filling.

  7. Comparison of the COMRADEX-IV and AIRDOS-EPA methodologies for estimating the radiation dose to man from radionuclide releases to the atmosphere

    International Nuclear Information System (INIS)

    Miller, C.W.; Hoffman, F.O.; Dunning, D.E. Jr.

    1981-01-01

    This report presents a comparison between two computerized methodologies for estimating the radiation dose to man from radionuclide releases to the atmosphere. The COMRADEX-IV code was designed to provide a means of assessing potential radiological consequences from postulated power reactor accidents. The AIRDOS-EPA code was developed primarily to assess routine radionuclide releases from nuclear facilities. Although a number of different calculations are performed by these codes, three calculations are in common - atmospheric dispersion, estimation of internal dose from inhalation, and estimation of external dose from immersion in air containing gamma emitting radionuclides. The models used in these calculations were examined and found, in general, to be the same. Most differences in the doses calculated by the two codes are due to differences in values chosen for input parameters and not due to model differences. A sample problem is presented for illustration

  8. Comparison of analytical charge-form and equilibrium thermodynamic speciation of certain radionuclides

    International Nuclear Information System (INIS)

    Jenne, E.A.; Cowan, C.E.; Robertson, D.E.

    1984-01-01

    Calculating trace element speciation with a thermodynamic model is often challenged on the basis that the existing thermodynamic data are not sufficiently reliable. Water quality data and corresponding analytical charge-form speciation analysis were available for radionuclides occurring in a low-level radioactive groundwater. This offered an opportunity for comparing the results of an equilibrium thermodynamic model with the results of analytical charge-form speciation. The charge-form speciation was determined using the Battelle Large Volume Water Sampler, which contains consecutive layers of cation resin, anion resin and activated aluminum oxide for retention of cationic, anionic and non-ionic dissolved chemical species, respectively. The thermodynamic speciation of Cs, Cr, Fe, I, Mn, Mo, Na, and Zn was calculated using the MINTEQ geochemical model. Ce, Co, Tc, Np, Pm, and Sb were speciated by hand calculation. Excellent agreement between the analytically determined charge-form and the thermodynamic speciation was observed for 54 Mn, 144 Ce, 131 I, 24 Na, 137 Cs, 99 Mo, 99 Tc, 151 Pm, 239 Np. Organic complexation by natural and/or synthetic organics in the waters may be important in the speciation of 65 An, 60 Co, 131 I, 59 Fe and possibly 51 Cr. Both 124 Sb and 125 Sb appeared to be in redox disequilibria with the groundwater. 29 references, 2 tables

  9. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning.

    Science.gov (United States)

    Kunst, P W; Vonk Noordegraaf, A; Hoekstra, O S; Postmus, P E; de Vries, P M

    1998-11-01

    Electrical impedance tomography (EIT) is a technique that makes it possible to measure ventilation and pulmonary perfusion in a volume that approximates to a 2D plane. The possibility of using EIT for measuring the left-right division of ventilation and perfusion was compared with that of radionuclide imaging. Following routine ventilation (81mKr) and perfusion scanning (99mTc-MAA), EIT measurements were performed at the third and the sixth intercostal level in 14 patients with lung cancer. A correlation (r = 0.98, p RC) was calculated for estimating the left-right division with EIT. The RC for the ventilation measurements was 94% and 96% for the perfusion measurements. The correlation analysis for reproducibility of the EIT measurements was 0.95 (p < 0.001) for the ventilation and 0.93 (p < 0.001) for the perfusion measurements. In conclusion, EIT can be regarded as a promising technique to estimate the left-right division of pulmonary perfusion and ventilation.

  10. Compilation and comparison of radionuclide sorption databases used in recent performance assessments

    International Nuclear Information System (INIS)

    McKinley, I.G.; Scholtis, A.

    1992-01-01

    The aim of this paper is to review the radionuclide sorption databases which have been used in performance assessments published within the last decade. It was hoped that such a review would allow areas of consistency to be identified, possibly indicating nuclide/rock/water systems which are now well characterised. Inconsistencies, on the other hand, might indicate areas in which further work is required. This study followed on from a prior review of the various databases which had been used in Swiss performance assessments. The latter was, however, considerably simplified by the fact that the authors had been heavily involved in sorption database definition for these assessments. The first phase of the current study was based entirely on available literature and it was quickly evident that the analyses would be much more complex (and time consuming) than initially envisaged. While some assessments clearly list all sorption data used, others depend on secondary literature (which may or may not be clearly referenced) or present sorption data which has been transmogrified into another form (e.g. into a retardation factor -c.f. following section). This study focused on database used (or intended) for performance assessment which have been published within the last 10 years or so. 45 refs., 12 tabs., 1 fig

  11. Clinical evaluation of right ventricular function using radionuclide method

    International Nuclear Information System (INIS)

    Ishii, Yasushi; Tamaki, Nagayoshi; Mukai, Takao; Motohara, Seiichito; Ikekubo, Katsuji.

    1982-01-01

    Essential thing to evaluate the right ventricular (RV) function is its volumetric measurement. However, its geometrical complexity has hampered this even with the contrast ventriculography, unlike left ventricle (LV). Meanwhile, the radionuclide time-activity curve from the first pass of a tracer through RV in the RAO view provides the most reliable data of the RV ejection fraction (RVEF), same data from the multigated equilibrium study in the LAO view is necessitated for a repeated intervention study, but the latter imposes a critical problem to locate ROI separately in the LAO view. Finally, three dimensional location of RV should be mandatory using new method as the dynamic SPECT in the future. (author)

  12. Radionuclide venography of lower limbs by subcutaneous injection; Comparison with venography by intravenous injection

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chung-Chieng; Jong, Shiang-Bin (Kaohsiung Medical College, Kaohsiung (Taiwan))

    1989-11-01

    We have proved that subcutaneous injection (SC) of a small dose of Tc-99m pertechnetate (1 to 2 mCi: 37 to 74 MBq) at acupuncture points (K-3 and B-60) may offer an alternative method of radionuclide venography (RNV) of the lower limbs. In this study, we compared intravenous (IV) RNV and SC-RNV in 22 consecutive cases with typical signs and symptoms suggesting venous abnormality of the lower limb(s) from March to May 1988. They are 11 male and 11 female, aged 47.7{plus minus}15.7 years. Among the 44 limbs of the 22 cases, 4 were normal, 12 (27.3%) were found to have varicose veins in the legs only, 18 (40.9%) had partial stenosis of the deep veins (14 poplito-tibial and 4 superficial femoral), and 13 (29.6%) had complete stenosis of the deep veins (4 poplito-tibial, 1 superficial femoral and 8 ilio-femoral). SC-RNV showed almost the same results as IV-RNV in 21 (47.7%), superior to IV-RNV in 22 (50%) (including 4.6% failure of IV-RNV), and inferior to IV-RNV in 1 (2.3%). We conclude that SC-RNV is definitely an alternative method of lower-limb venography. Since it is in most cases superior to IV-RNV, we suggest that it can take the place of IV-RNV in routine work. (author) 62 refs.

  13. Recent trends of plutonium deposition observed in Japan: comparison with naturallithogenic radionuclides, thorium isotopes

    International Nuclear Information System (INIS)

    Hirose, K.; Igarashi, Y.; Aoyama, M.

    2005-01-01

    Plutonium in monthly deposition samples from 2000 to end of 2003 collected to Tsukuba (the Meteorological Research Institute), Japan is reported, together with monthly thorium deposition. The annual deposition of 239,240 Pri during the past 18 years. ranged from 1.7 to 7.8 mBq m -2 y -1 shows no systematic inter-annual variation. However, a maximum annual 239,240 Pu deposition (7.8 mBq m -2 y -1 ) was observed in 2002. On the other hand, monthly 239,240 Pu depositions show a typical seasonal variation with a maximum in spring season (March to April), which corresponds to the seasonal cycle of generation of dust storms in the East Asian arid area. Thorium, which is a typical lithogenic radionuclide, reflects soil-derived particles in the atmospheric dust. The monthly Th deposition showed a typical seasonal trend with a maximum in spring and minimum in summer. The 230 Th/ 232 Th activity ratios in the deposition samples significantly differed from that in surface soils collected in Tsukuba area, which means that a significant part of thorium in deposition samples is not derived from suspension of local soil particles. The result reveals that the resent 239,240 Pu deposition observed in Japan are attributed to resuspension of deposited plutonium; resuspended plutonium originates from the East Asian continent desert and arid areas. These findings suggest that a significant amount of soil dust observed in Tsukuba is attributable to the long-range transport of continental dust from the East Asian arid areas. Plutonium in deposition samples as does thorium would become a proxy of the environmental change in the Asian continent.

  14. Activity measurements of the radionuclide {sup 111}In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G.; Courte, S. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, 92 - Sevres (France); Verdeau, E.; Amiot, M.N. [Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France)

    2010-10-15

    In 2006, the Laboratoire national de metrologie et d'essais - Laboratoire national Henri Becquerel (LNE-LNHB) submitted a sample of known activity of {sup 111}In to the International Reference System (SIR). The value of the activity submitted was about 14 MBq. This provides a new result for France in the matrix of degrees of equivalence in the key comparison database that enables them to maintain their degrees of equivalence for this radionuclide. The key comparison reference value has been re-evaluated and the comparison, identifier BIPM.RI(II)-K1.In-111, now contains five valid results. (authors)

  15. Ventriculography and cisternography with water-soluble contrast media in infants with myelomeningocele

    International Nuclear Information System (INIS)

    Yamada, H.; Nakamura, S.; Tanaka, Y.; Tajima, M.; Kageyama, N.

    1982-01-01

    Fifty-four newborn infants with myelomeningocele and hydrocephalus were studied by ventriculography using water-soluble contrast media; 20 were also studied by metrizamide myeloencephalography and computerized tomographic (CT) cisternography. Ventriculography suggested that the aqueduct was patent in all cases. Outflow of contrast medium from the fourth ventricle was slow in most cases, complete obstruction was seen in 15%, communication was delayed at the outlet in 54%, and rather free communication was observedin 31%. Metrizamide myeloencephalography and CT cisternography suggested a partial block at the level of the ambient cisterns in approximately one-third of infants. These findings support the concept that flow of cerebrospinal fluid is reduced in several areas. Aqueductal stenosis was not considered an important factor in hydrocephalus, while the most important site of obstruction was felt to be the lowest portion of the fourth ventricle

  16. Right-sided phase abnormalities on gated blood pool ventriculography: Demonstration of six different patterns

    International Nuclear Information System (INIS)

    Bahar, R.H.; Abdel-Dayem, H.M.; Ziada, G.; Al-Suhali, A.; Constantinides, C.; Nair, K.M.

    1986-01-01

    Phase pattern abnormalities on multiple gated blood pool ventriculography are better reported for the left ventricle (LV) than for the right side of the heart. In a study of 92 patients who also underwent contrast ventriculography, the authors identified six different patterns of right-sided phase abnormalities and their causes: right bundle-branch block, causing delayed phase in the entire right ventricle (RV); ischemic right coronary artery disease, causing delayed phase in the inferior RV wall; pericardial effusion, causing an L-shaped area of delayed phase to the right of the septum and below the LV; pulmonary hypertension, causing delayed phase in the pulmonary infundibulum; tricuspid regurgitation, causing a crescentic area of delayed phase around and below the right RV and extending below the LV as well, and atrial septal defect causing an abnormally large auricular phase

  17. Radionuclide trap

    International Nuclear Information System (INIS)

    McGuire, J.C.

    1978-01-01

    The deposition of radionuclides manganese-54, cobalt-58 and cobalt-60 from liquid sodium coolant is controlled by providing surfaces of nickel or high nickel alloys to extract the radionuclides from the liquid sodium, and by providing surfaces of tungsten, molybdenum or tantalum to prevent or retard radionuclide deposition

  18. Right ventriculography as a valid method for the diagnosis of tricuspid insufficiency.

    Science.gov (United States)

    Ubago, J L; Figueroa, A; Colman, T; Ochoteco, A; Rodríguez, M; Durán, C M

    1981-01-01

    The value of right ventriculography in the diagnosis of tricuspid insufficiency (TI) is often questioned because of 1) the high incidence of premature ventricular contractions (PVCs) during injections and 2) interference of the catheter in the valve closure mechanism. In 168 patients a commercially available, not preshaped, balloon-tipped catheter was used for right ventriculography. To avoid the induction of PVCs, the catheter tip was placed in the middle third of the diafragmatic wall of the right ventricle, and the balloon was inflated, becoming trapped by the trabeculae. In this position the catheter's side holes should be located in the inflow chamber. To ensure this correct position, and therefore lack of ectopic beats during angiography, a saline test injection was performed previously in every case. With this technique the incidence of PVCs during ventriculography was only 7.7%. In all but one case, such beats were isolated. The 168 patients were divided into three groups according to their likelihood of experiencing tricuspid interference by the catheter: group 1 included 41 patients with a normal heart or with coronary artery disease. No one from this group had TI. Of group II, 28 patients with right ventricular pressure or volume overload or cardiomyopathy, only 2 had TI, both with a previous clinical diagnosis of regurgitation. Group III contained 99 patients with rheumatic heart disease. Thirty-five of them showed angiographic TI, and 24 of these had this diagnosis confirmed either clinically or at surgery. It is felt that this technique of right ventriculography, with its low incidence of PVCs and slight interference with tricuspid closure, is a valid method for the objective study of the tricuspid valve.

  19. Magnetic resonance ventriculography with gadolinium DTPA: report of two cases

    International Nuclear Information System (INIS)

    Siebner, H.R.; Einsiedel, H. von; Conrad, B.

    1997-01-01

    We report intrathecal use of gadolinium DTPA for MRI of the cerebrospinal fluid (CSF). In two patients with leptomeningeal carcinomatosis, we injected 0.01 mmol gadolinium DTPA into the lateral ventricle via an Ommaya device. Coronal T1-weighted images of the head were obtained at 0.2 T prior to and after injection. There was pronounced enhancement of CSF close to the injection site, allowing good delineation of CSF and surrounding brain tissue. No side effects occurred. MRI with intrathecal administration of highly diluted gadolinium DTPA may be a promising alternative to conventional investigation of CSF-filled cavities using iodinated X-ray contrast media or radionuclides. (orig.). With 3 figs

  20. State of radionuclides in seawater. Comparison of natural stable and artificial radioactive isotope s of mercury and zinc in natural waters of the arid zone of the USSR

    International Nuclear Information System (INIS)

    Rakhmatov, U; Khikmatov, K; Kist, A.A.; Kulmatov, R.A.; Teshabaev, S.T.; Volkov, A.A.

    1986-01-01

    This paper studies the state of stable and artificial radioactive isotopes of merury and zinc in natural waters of the arid zone of the USSR by radioactivity and radiochemical methods. Convergent results have been obtained for the dissolved forms of mercury and zinc in natural waters of the arid zone in a comparison of the results of radioactivation analysis and laboratory simulation using the radionuclides mercury-203 and zinc-65

  1. Evaluation of the effect of different types and location of pacemaker on cardiac function using radionuclide techniques

    International Nuclear Information System (INIS)

    Shi Rongfang; Liu Xiujie; Guo Xiuzhen

    1993-01-01

    Left ventricular function was measured in 24 patients using radionuclide ventriculography before and after planting different types of pacemakers. The results showed that the heart rate, peak filling rate (PFR) and relative cardiac output (RCO) were significantly increased after planting the pacemaker. However, the effects of AAI and VVI on the synchronism of LV were different. AAI can significantly improve the synchronism and compliance of LV

  2. Radionuclide migration in groundwater at a low-level waste disposal site: a comparison of predictive performance modeling versus field observations

    International Nuclear Information System (INIS)

    Robertson, D.E.; Myers, D.A.; Bergeron, M.P.; Champ, D.R.; Killey, R.W.D.; Moltyaner, G.L.; Young, J.L.

    1985-08-01

    This paper describes a project which is structured to test the concept of modeling a shallow land low-level waste burial site. The project involves a comparison of the actual observed radionuclide migration in groundwaters at a 30-year-old well-monitored field site with the results of predictive transport modeling. The comparison is being conducted as a cooperative program with the Atomic Energy of Canada Ltd. (AECL) at the low-level waste management area at the Chalk River Nuclear Laboratories, Ontario, Canada. A joint PNL-AECL field inviestigation was conducted in 1983 and 1984 to complement the existing extensive data base on actual radionuclide migration. Predictive transport modeling is currently being conducted for this site; first, as if it were a new location being considered for a low-level waste shallow-land burial site and only minimal information about the site were available, and second, utilizing the extensive data base available for the site. The modeling results will then be compared with the empirical observations to provide insight into the level of effort needed to reasonably predict the spacial and temporal movement of radionuclides in the groundwater enviroment. 8 refs., 5 figs.,

  3. Radionuclide migration in groundwater at a low-level waste disposal site: a comparison of predictive performance modeling versus field observations

    International Nuclear Information System (INIS)

    Robertson, D.E.; Myers, D.A.; Abel, K.H.; Bergeron, M.P.; Champ, D.R.; Killey, R.W.D.; Moltyaner, G.L.; Young, J.L.

    1986-01-01

    This paper describes a project which is structured to test the concept of modeling a shallow land low-level waste burial site. The project involves a comparison of the actual observed radionuclide migration in groundwaters at a 30-year old well-monitored field site with the results of predictive transport modeling. The comparison is being conducted as a cooperative program with the Atomic Energy of Canada Ltd. (AECL) at the low-level waste management area at the Chalk River Nuclear Laboratories, Ontario, Canada. A joint PNL-AECL field investigation was conducted in 1983 and 1984 to compliment the existing extensive data base on actual radionuclide migration. Predictive transport modeling is currently being conducted for this site; first, as if it were a new location being considered for a low-level waste shallow-land burial site and only minimal information about the site were available, and second, utilizing the extensive data base available for the site. The modeling results will then be compared with the level of effort needed to reasonably predict the spacial and temporal movement of radionuclides in the groundwater environment

  4. Ventricular dysfunction in children with obstructive sleep apnea: radionuclide assessment

    International Nuclear Information System (INIS)

    Tal, A.; Leiberman, A.; Margulis, G.; Sofer, S.

    1988-01-01

    Ventricular function was evaluated using radionuclide ventriculography in 27 children with oropharyngeal obstruction and clinical features of obstructive sleep apnea. Their mean age was 3.5 years (9 months to 7.5 years). Conventional clinical assessment did not detect cardiac involvement in 25 of 27 children; however, reduced right ventricular ejection fraction (less than 35%) was found in 10 (37%) patients (mean: 19.5 +/- 2.3% SE, range: 8-28%). In 18 patients wall motion abnormality was detected. In 11 children in whom radionuclide ventriculography was performed before and after adenotonsillectomy, right ventricular ejection fraction rose from 24.4 +/- 3.6% to 46.7 +/- 3.4% (P less than 0.005), and in all cases wall motion showed a definite improvement. In five children, left ventricular ejection fraction rose greater than 10% after removal of oropharyngeal obstruction. It is concluded that right ventricular function may be compromised in children with obstructive sleep apnea secondary to adenotonsillar hypertrophy, even before clinical signs of cardiac involvement are present

  5. Exercise radionuclide ventriculographic responses in hypertensive patients with chest pain

    International Nuclear Information System (INIS)

    Wasserman, A.G.; Katz, R.J.; Varghese, P.J.; Leiboff, R.H.; Bren, G.G.; Schlesselman, S.; Varma, V.M.; Reba, R.C.; Ross, A.M.

    1984-01-01

    The effectiveness of exercise-treadmill testing in diagnosing coronary-artery disease in hypertensive patients is limited by a high rate of false positivity. Exercise radionuclide ventriculography, however, relies on different criteria (ejection fraction and wall motion), and we have evaluated this procedure in 37 hypertensive and 109 normotensive patients with chest pain, using coronary arteriography as an indicator of coronary disease. In the hypertensive cohort there was no difference in the ejection fraction at rest between the 17 patients with coronary disease and the 20 without it. Neither group had a significant mean (+/- S.E.M.) change in ejection fraction from rest to exercise (-1.9 +/- 2 and 1.4 +/- 1%, respectively). A wall-motion abnormality developed during exercise in 5 of the 17 hypertensive patients with coronary disease (29%) and in 4 of the 20 without it (20%) (P = not significant). In the normotensive cohort, however, the peak-exercise ejection fractions were significantly different. The 71 patients with coronary disease had a mean decrease of 3.6 +/- 1%, in contrast to the patients without coronary disease, who had an increase of +/- 1% (P < 0.001). An exercise-induced wall-motion abnormality was seen in 35 of the 71 patients with coronary disease (48%), as compared with 3 of the 38 without it (8%) (P < 0.001). We conclude that exercise radionuclide ventriculography is inadequate as a screening test for coronary atherosclerosis in hypertensive patients with chest pain. 28 references, 2 figures, 3 tables

  6. Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography

    International Nuclear Information System (INIS)

    Dell'Italia, L.J.; Starling, M.R.; Walsh, R.A.; Badke, F.R.; Lasher, J.C.; Blumhardt, R.

    1985-01-01

    To determine the accuracy of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volumes, the authors initially studied 14 postmortem human right ventricular casts by water displacement and biplane cineventriculography. Biplane cineventriculographic right ventricular cast volumes, calculated by a modification of Simpson's rule algorithm, correlated well with right ventricular cast volumes measured by water displacement (r = .97, y = 8 + 0.88x, SEE = 6 ml). Moreover, the mean volumes obtained by both methods were no different (73 +/- 28 vs 73 +/- 25 ml). Subsequently, they studied 16 patients by both biplane cineventriculography and equilibrium radionuclide angiography. The uncorrected radionuclide right ventricular volumes were calculated by normalizing background corrected end-diastolic and end-systolic counts from hand-drawn regions of interest obtained by phase analysis for cardiac cycles processed, frame rate, and blood sample counts. Attenuation correction was performed by a simple geometric method. The attenuation-corrected radionuclide right ventricular end-diastolic volumes correlated with the cineventriculographic end-diastolic volumes (r = .91, y = 3 + 0.92x, SEE = 27 ml). Similarly, the attenuation-corrected radionuclide right ventricular end-systolic volumes correlated with the cineventriculographic end-systolic volumes (r = .93, y = - 1 + 0.91x, SEE = 16 ml). Also, the mean attenuation-corrected radionuclide end-diastolic and end-systolic volumes were no different than the average cineventriculographic end-diastolic and end-systolic volumes (160 +/- 61 and 83 +/- 44 vs 170 +/- 61 and 86 +/- 43 ml, respectively)

  7. Radionuclide diagnosis of emergency states

    International Nuclear Information System (INIS)

    Ishmukhametov, A.I.

    1985-01-01

    Solution of emergency state radionuclide diagnostics from the technical point of view is provided by the application of the mobile quick-operating equipment in combination with computers, by the use of radionuclides with acceptable for emergency medicine characteristics and by development of radionuclide investigation data propcessing express-method. Medical developments include the study of acute disease and injury radioisotope semiotics, different indication diagnostic value determining, comparison of the results, obtained during radionuclide investigation, with clinicolaboratory and instrumental data, separation of methodical complex series

  8. Positive ventriculography and computer assisted tomography of the skull in the evaluation of megalocephaly in newborns and infants

    International Nuclear Information System (INIS)

    Kellermann, K.; Heuser, L.; Bliesener, J.A.

    1979-01-01

    To clarify indications and limits of computer assisted tomography and positive ventriculography the results of both methods were compared with each other retrospectively in 55 macrocephalic newborns and infants. It could be shown that positive ventriculography, even if combined with coronal views, was superseded by computer assisted tomography to only a certain extent. To complete the appropriate diagnosis preoperatively positive ventriculography was necessary most often in patients with paranatal disturbances who had undergone intensive care treatment. The non-invasive method of computer assisted tomography often yielded sufficient information on localisation, size, and nature of the underlying pathologic process. Both methods turned out to be complementary when topographical and functional interrelations of cranial cysts were to be analysed, or when anatomical details had to be demonstrated, especially structures of the midline and of the posterior fossa, which could not be visualized by computer assisted tomography alone. (orig.) [de

  9. Radionuclide cisternography

    International Nuclear Information System (INIS)

    Song, H.H.

    1980-01-01

    The purpose of this thesis is to show that radionuclide cisternography makes an essential contribution to the investigation of cerebrospinal fluid (CSF) dynamics, especially for the investigation of hydrocephalus. The technical details of radionuclide cisternography are discussed, followed by a description of the normal and abnormal radionuclide cisternograms. The dynamics of CFS by means of radionuclide cisternography were examined in 188 patients in whom some kind of hydrocephalus was suspected. This study included findings of anomalies associated with hydrocephalus in a number of cases, such as nasal liquorrhea, hygromas, leptomeningeal or porencephalic cysts. The investigation substantiates the value of radionuclide cisternography in the diagnosis of disturbances of CSF flow. The retrograde flow of radiopharmaceutical into the ventricular system (ventricular reflux) is an abnormal phenomenon indicating the presence of communicating hydrocephalus. (Auth.)

  10. Comparison of bone tumors induced by beta-emitting or alpha-emitting radionuclides: Schemes of pathogenesis

    International Nuclear Information System (INIS)

    Gillett, N.A.; Muggenburg, B.A.; Pool, R.R.; Hahn, F.F.

    1988-01-01

    Life-span studies in Beagle dogs have documented the occurrence of bone tumors following exposure to bone-seeking alpha- or beta-emitting radionuclides administered by different routes of exposure. Bone tumors from dogs in four different life-span studies were analyzed according to tumor phenotype, tumor location, radiographic appearance, incidence of metastasis, and association with radiation osteodystrophy. Marked differences in these parameters were observed that did not correlate with differences in radionuclide type, route of exposure, or duration of radionuclide uptake. Radiation osteodystrophy, which is postulated to be a preneoplastic lesion, was not a significant component in one of the studies. Analysis of the data from these four studies suggests that at least two different mechanisms of bone tumor pathogenesis occur for radiation-induced bone tumors. (author)

  11. SU-E-T-15: A Comparison of COMS and EP917 Eye Plaque Applicators Using Different Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Aryal, P; Molloy, JA [University of Kentucky, Lexington, KY (United States); Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States)

    2015-06-15

    Purpose: To investigate the effect of plaque design and radionuclides on eye plaque dosimetry. Methods: The Monte Carlo N-particle Code version 6 (MCNP6) was used for radiation transport simulations. The 14 mm and 16 mm diameter COMS plaques and the model EP917 plaque were simulated using brachytherapy seeds containing I-125, Pd-103, and Cs-131 radionuclides. The origin was placed at the scleral inner surface. The central axis (CAX) doses of both COMS plaques at −1 mm, 0 mm, 1 mm, 2 mm, 5 mm, 10 mm, 15 mm, 20 mm, and 22.6 mm were compared to the model EP917 plaque. Dose volume histograms (DVHs) were also created for both COMS plaques for the tumor and outer sclera then compared to results for the model EP917 plaque. Results: For all radionuclides, the EP917 plaque delivered higher dose (max 343%) compared to the COMS plaques, except for the 14 mm COMS plaque with Cs-131 at 1 mm and 2 mm depths from outer sclera surface. This could be due to source design. For all radionuclides, the 14 mm COMS plaque delivered higher doses compared to the 16 mm COMS plaque for the depths up to 5 mm. Dose differences were not significant beyond depths of 10 mm due to ocular lateral scatter for the different plaque designs. Tumor DVHs for the 16 mm COMS plaque with Cs-131 provided better dose homogeneity and conformity compared to other COMS plaques with I-125 and Pd-103. Using Pd-103, DVHs for the 16 mm COMS plaque delivered less dose to outer sclera compared to other plaques. Conclusion: This study identified improved tumor homogeneity upon considering radionuclides and plaque designs, and found that scleral dose with the model EP917 plaque was higher than for the 16 mm COMS plaque for all the radionuclides studied.

  12. Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Roos, Per

    2008-01-01

    application in the environmental and biological researches, these radionuclides include H-3, C-14, Cl-36, Ca-41 Ni-59,Ni-63, Sr-89,Sr-90, Tc-99, I-129, Cs-135,Cs-137, Pb-210, Ra-226,Ra-228, Np-237, Am-241, and isotopes of thorium, uranium and plutonium. The application of on-line methods (flow injection...

  13. Clinical experience with a non-ionic contrast medium (ultravist) in left ventriculography

    International Nuclear Information System (INIS)

    Lee, Ghi Jai; Park, Jae Hyung; Soe, Gwy Suk; Hong, Ju Hee; Han, Man Chung

    1988-01-01

    Non-ionic contrast medium, iopromide (Ultravist), was compared with ionic contrast medium, ioxitalamate (Telebrix), for efficacy and safety in 63 patients undergoing left ventriculography. In all patients, adverse symptoms and signs including pain, heat sense, nausea, vomiting, etc., were checked during and shortly after the injection. Blood pressure, heart rate, EKG and left ventricular pressure were also monitored during the study, and CBC, UA, BUN and creatinine were checked before and 24 hours after the study. The cineangiographic films were analysed and compared by 2 radiologists for the quality. Serious adverse effect did not occur in any case. Minor effects, especially nausea, were lee frequently caused by non-ionic contrast medium than by ionic contrast medium, and heat sense to non-ionic contrast medium was less severe than to ionic contrast medium. Except slightly elevated LVEDP at 1,5 minutes after the study in patients given ionic contrast medium, there was no significant change of electrophysiologic parameters and laboratory findings in both groups. In regard to image quality, there was no significant difference between ionic and non-ionic contrast medium. Thus non-ionic contrast medium, iopromide, appears to be safer for use in left ventriculography than the conventional ionic contrast medium, particularly in those patients at high risk of adverse effects.

  14. Radionuclide carrier

    International Nuclear Information System (INIS)

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  15. Dynamic models for radionuclide transport in agricultural ecosystems: summary of results from a UK code comparison exercise

    International Nuclear Information System (INIS)

    Meekings, G.F.; Walters, B.

    1986-01-01

    In recent years, models have been developed by three organisations in the UK to represent the time-dependent behaviour of radionuclides in agricultural ecosystems. These models were developed largely independently of each other and, in view of their potential applications in relation to radioactive waste management and discharge, the Food Science Division of the Ministry of Agriculture, Fisheries and Food initiated a calculational intercomparison exercise with the agreement and cooperation of all three organisations involved. A subset of the results obtained is reported here. In general a high degree of consistency between the results of the various models was obtained particularly regarding the responses with time. The exercise supported the case for using dynamic models in radiological assessment studies. It also demonstrated areas where differences in results from the models are a consequence of a lack of appropriate data on the environmental behaviour of the radionuclides considered. (author)

  16. Comparison of concentrations of natural and artificial radionuclides in Plankton from French Polynesian and Australian coastal waters

    International Nuclear Information System (INIS)

    Poletiko, C.; Twining, J.R.; Jeffree, R.A.

    1994-01-01

    Zooplankton samples from French Polynesian and Australian coastal waters were analysed for natural and artificial radionuclides. Quality control was assured by correlating replicate analyses between three laboratories and by participation in an international intercomparison exercise. Pu239/240 was detected sporadically among samples from both regions, with the highest levels being more consistently found in Tuamotu-Gambier samples. The artificial radionuclides Cs-137, Cs-134, Sr-90 and Co-60 were not detected. Of the natural nuclides, Ac-228 was detected in shallow continental waters off Northern Australia and an inverse relationship (P<0.02) was established between plankton density and their Po-210 concentration. (authors). 2 figs., 2 tabs., 9 refs

  17. Detection of exercise induced ischemia in the asymptomatic recent post myocardial infarction patient: comparison of stress electrocardiography and radionuclide angiography

    International Nuclear Information System (INIS)

    Jengo, J.A.; Brizendine, M.; Dykstra, L.; Sweet, J.; Bruno, M.; Garcia, A.

    1982-01-01

    The purpose of this study was to compare the techniques of low level stress electrocardiography and radionuclide angiographic wall motion analysis for the detection of new areas of myocardial ischemia in the asymptomatic recent post-myocardial infarction patient. The protocol consisted of obtaining a resting, RAO upright first pass radionuclide angiocardiogram using 15 mCi of 99m technetium-DTPA. The study suggests that assessment of segmental wall motion during low level stress can detect areas of myocardium at high risk either intermixed with or in addition to recently infarcted areas in the asymptomatic post-infarction patient, which are not detected by ECG. This high risk subset of patients can then be observed or treated in a more vigorous manner. This technique allows for not only the identification of additional areas of myocardium at jeopardy but also provides information regarding the severity of ischemic dysfunction, an important prognostic and therapeutic factor

  18. Comparison of gated radionuclide scans and chest radiographs. Assessment of left ventricular impairment in patients with coronary disease.

    Science.gov (United States)

    Bianco, J A; Reinke, D B; Makey, D G; Shafer, R B

    1980-03-01

    Diagnostic efficacy of gated cardiac blood pool imaging was studied in 41 consecutive patients with LV ejection fractions (LVEF) less than or equal to 0.50. Eighty percent of patients were receiving therapy for LV failure at the time of the study. All patients had documented coronary-artery disease (CAD). Chest x-ray films were interpreted blindly by a senior radiologist. Cardiothoracic ratio of less than or equal to 0.50 was recorded as normal. Radionuclide assessment of LV function contributes importantly to the diagnostic and screening value of chest x-ray films. Patients with coronary disease and clinical evidence of heart failure should have radioisotopic studies even if chest x-ray film findings are normal. In patients with coronary artery disease and enlarged LV on chest films, radionuclide study of left ventricular performance aids in defining LV impairment, and in the prognostication of subsequent clinical course.

  19. Comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-04-01

    First-pass radionuclide angiography (FPRA) in the 30/sup 0/ right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45/sup 0/ left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA.

  20. A comparison of two radionuclide ejection-fraction techniques with contrast angiography in ischemic heart disease and valvular heart disease

    International Nuclear Information System (INIS)

    Hassan, I.M.; Abdel-Dayem, H.M.; Mohammed, M.M.J.; Simo, M.; Yousef, A.M.; Badruddosa, M.; Mahmood, A.R.; Sayed, M.E.

    1986-01-01

    First-pass radionuclide angiography (FPRA) in the 30 0 right anterior oblique and equilibrium gated radionuclide angiography (EGNA) in the 45 0 left anterior oblique were used for quantitative measurements of left ventricular ejection fraction (LVEF). Equipment used was a 400T gamma-camera interfaced with a Simis III Informatek computer. The results were compared with contrast angiography (CA). The aim of this study was to determine the sensitivity of both radionuclide techniques. The present data are based on 65 patients in whom CA and EGNA were performed. In 47 patients both FPRA and EGNA were performed. Results suggested that in ischemic heart disease (IHD) and valvular heart disease (VHD) the EGNA technique is well correlated with CA (r=0.9 and 0.73, respectively). FPRA correlated well only with CA in IHD (r=0.86), but not in VHD (r=0.18). This study indicates that both FPRA and EGNA are sensitive, noninvasive techniques for measuring ejection fraction in IHD, while in VHD, EGNA is more sensitive technique than FPRA. (orig.)

  1. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome. Assessment by radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko and others

    1989-04-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author).

  2. Radionuclide data

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Chapter 8 presents tables on selected alpha, beta, gamma and x-ray emitters by increasing energy; information on specific activity for selected radionuclides; naturally occurring radionuclides; the natural decay series; and the artificially produced neptunium series. A table of alpha emitters is listed by increasing atomic number and by energy. The table of β emitters presented is useful in identifying β emitters whose energies and possibly half-lives have been determined by standard laboratory techniques. It is also a handy guide to β-emitting isotopes for applications requiring specific half-lives and/or energies. Gamma rays for radionuclides of importance to radiological assessments and radiation protection are listed by increasing energy. The energies and branching ratios are important for radionuclide determinations with gamma spectrometry detectors. This section also presents a table of x-ray energies which are useful for radiochemical analyses. A number of nuclides emit x-rays as part of their decay scheme. These x-rays may be counted with Ar proportional counters, Ge planar or n-type Ge co-axial detectors, or thin crystal NaI(T1) scintillation counters. In both cases, spectral measurements can be made and both qualitative and quantitative information obtained on the sample. Nuclear decay data (energy and probability by radiation type) for more than one hundred radionuclides that are important to health physicists are presented in a schematic manner

  3. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.

    1983-01-01

    The status of radionuclide generators for chemical research and applications related to the life sciences and biomedical research are reviewed. Emphasis is placed upon convenient, efficient and rapid separation of short-lived daughter radionuclides in a chemical form suitable for use without further chemical manipulation. The focus is on the production of the parent, the radiochemistry associated with processing the parent and daughter, the selection and the characteristic separation methods, and yields. Quality control considerations are briefly noted. The scope of this review includes selected references to applications of radionuclide generators in radiopharmaceutical chemistry, and the life sciences, particularly in diagnostic and therapeutic medicine. The 99 Mo-sup(99m)Tc generator was excluded. 202 references are cited. (orig.)

  4. Numerical modeling of the radionuclide water pathway with HYDRUS and comparison with the IAEA model of SR 44.

    Science.gov (United States)

    Merk, Rainer

    2012-02-01

    This study depicts a theoretical experiment in which the radionuclide transport through the porous material of a landfill consisting of concrete rubble (e.g., from the decommissioning of nuclear power plants) and the subsequent migration through the vadose zone and aquifer to a model well is calculated by means of the software HYDRUS-1D (Simunek et al., 2008). The radionuclides originally contained within the rubble become dissolved due to leaching caused by infiltrated rainwater. The resulting well-water contamination (in Bq/L) is calculated numerically as a function of time and location and compared with the outcome of a simplified analytic model for the groundwater pathway published by the IAEA (2005). Identical model parameters are considered. The main objective of the present work is to evaluate the predictive capacity of the more simple IAEA model using HYDRUS-1D as a reference. For most of the radionuclides considered (e.g., ¹²⁹I, and ²³⁹Pu), results from applying the IAEA model were found to be comparable to results from the more elaborate HYDRUS modeling, provided the underlying parameter values are comparable. However, the IAEA model appears to underestimate the effects resulting from, for example, high nuclide mobility, short half-life, or short-term variations in the water infiltration. The present results indicate that the IAEA model is suited for screening calculations and general recommendation purposes. However, the analysis of a specific site should be accompanied by detailed HYDRUS computer simulations. In all models considered, the calculation outcome largely depends on the choice of the sorption parameter K(d). Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Experimental study and nuclear model calculations on the $^{192}Os (p, n)^{192}$Ir reaction Comparison of reactor and cyclotron production of the therapeutic radionuclide $^{192}$Ir

    CERN Document Server

    Hilgers, K; Sudar, S; 10.1016/j.apradiso.2004.12.010

    2005-01-01

    In a search for an alternative route of production of the important therapeutic radionuclide /sup 192/Ir (T/sub 1/2/=78.83 d), the excitation function of the reaction /sup 192/Os(p, n)/sup 192/Ir was investigated from its threshold up to 20MeV. Thin samples of enriched /sup 192/Os were obtained by electrodeposition on Ni, and the conventional stacked-foil technique was used for cross section measurements. The experimental data were compared with the results of theoretical calculations using the codes EMPIRE-II and ALICE-IPPE. Good agreement was found with EMPIRE-II, but slightly less with the ALICE-IPPE calculations. The theoretical thick target yield of /sup 192/Ir over the energy range E/sub p/=16 to 8MeV amounts to only 0.16MBq/ mu A.h. A comparison of the reactor and cyclotron production methods is given. In terms of yield and radionuclidic purity of /sup 192/Ir the reactor method appears to be superior; the only advantage of the cyclotron method could be the higher specific activity of the product.

  6. Noninvasive assessment of right ventricular wall motion by radionuclide cardioangiography

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Radionuclide cardioangiography is a useful method to evaluate the left ventricular wall motion in various heart diseases. It has been also attempted to assess the right ventricular wall motion simultaneously by radionuclide method. In this study, using the combination of first-pass (RAO 30 0 ) and multi-gate (LAO 40 0 ) method, the site of right vetricle was classified in five. (1 inflow, 2 sinus, 3 outflow, 4 septal, 5 lateral) and the degree of wall motion was classified in four stages (dyskinesis, akinesis, hypokinesis, normal) according to the AHA committee report. These methods were applied clinically to forty-eight patients with various heart diseases. In the cases with right ventricular pressure or volume overload such as COLD, pulmonary infarction, the right ventricle was dilated and the wall motion was reduced in all portions. Especially, in the cases with right ventricular infarction, the right ventricular wall motion was reduced in the infarcted area. The findings of radionuclide method were in good agreement with those of contrast right ventriculography or echocardiography. In conclusion, radionuclide cardioangiography is a useful and noninvasive method to assess not only the left but also the right ventricular wall motion. (author)

  7. Radionuclide generators

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Wollongong Univ.; Tomiyoshi, K.; Sekine, T.

    1997-01-01

    The present status and future directions of research and development on radionuclide generator technology are reported. The recent interest to develop double-neutron capture reactions for production of in vivo generators; neutron rich nuclides for radio-immunotherapeutic pharmaceuticals: and advances with ultra-short lived generators is highlighted. Emphasis is focused on: production of the parent radionuclide; the selection and the evaluation of support materials and eluents with respect to the resultant radiochemical yield of the daughter, and the breakthrough of the radionuclide parent: and, the uses of radionuclide generators in radiopharmaceutical chemistry, biomedical and industrial applications. The 62 Zn → 62 Cu, 66 Ni → 66 Cu, 103m Rh → 103 Rh, 188 W → 188 Re and the 225 Ac → 221 Fr → 213 Bi generators are predicted to be emphasized for future development. Coverage of the 99 Mo → 99m Tc generator was excluded, as it the subject of another review. The literature search ended June, 1996. (orig.)

  8. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  9. Biological Dosimetry of In Vitro Irradiation with Radionuclides : Comparison of Whole Blood, Lymphocyte and Buffy Coat Culture

    International Nuclear Information System (INIS)

    Kim, Jong Ho; Lee, Dong Soo; Choi, Chang Woon; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Kim, Chong Soon; Kim, Hee Geun; Kang, Duck Won; Song, Myung Jae

    1995-01-01

    The purpose of this study was to establish mononuclear cell cultures such as lymphocytes or buffy coat for the biological dosimetry of in vitro irradiation of the radionuclide Tc-99m in order to exclude the effect of residual doses seen in the cultures of whole blood. Biological dosimetry of Tc-99m on cultured mononuclear cells at doses ranging from 0.05 to 6.00 Gy, by scoring unstable chromosomal aberrations(Ydr) observed in cultured lymphocytes, were performed using peripheral venous blood of healthy normal person. The results showed that; (1) In vitro irradiation of radioisotope in separated lymphocyte or buffy coat showed trace amount af residual doses of isotope after washing. Residual doses of isotopes are increased in proportion tn exposed time and irradiated dose without difference between I-131 anct Tc-99m. (2) We obtained these linear-quadratic dose response equations in lymphocyte and buffy coat culture after in vitro irradiation of Tc-99m, respectively (Ydr = 0,001949 D 2 +0,006279D+ 0.000185; Ydr= 0.002531 D 2 -0.003274 D+0.003488). In conclusion, the linear quadrstic dose response equation from in vitro irradiation of Tc-99m with lymphocyte and buffy coat culture was thought to be useful for assessing Tc-99m indueed biological effects. And mononuclear cell cultures seem to be the most appropriate experimental model for the assessment of biological dosimetry of internal irradiation of radionuclides.

  10. Comparison of two freshwater turtle species as monitors of radionuclide and chemical contamination: DNA damage and residue analysis

    International Nuclear Information System (INIS)

    Meyers-Schoene, L.; Shugart, L.R.; Beauchamp, J.J.; Walton, B.T.

    1993-01-01

    Two species of turtles that occupy different ecological niches were compared for their usefulness as monitors of freshwater ecosystems where both low-level radioactive and nonradioactive contaminants are present. The pond slider (Trachemys scripta) and common snapping turtle (Chelydra serpentina) were analyzed for the presence of 90 Sr, 137 Cs, 60 Co, and Hg, radionuclides and chemicals known to be present at the contaminated site, and single-strand breaks in liver DNA. The integrity of the DNA was examined by the alkaline unwinding assay, a technique that detects strand breaks as a biological marker of possible exposure to genotoxic agents. This measure of DNA damage was significantly increased in both species of turtles at the contaminated site compared with turtles of the same species at a reference site, and shows that contaminant-exposed populations were under more severe genotoxic stress than those at the reference site. The level of strand breaks observed at the contaminated site was high and in the range reported for other aquatic species exposed to deleterious concentrations of genotoxic agents such as chemicals and ionizing radiation. Statistically significantly higher concentrations of radionuclides and Hg were detected in the turtles from the contaminated area. Mercury concentrations were significantly higher in the more carnivorous snapping turtle compared with the slider; however, both species were effective monitors of the contaminants

  11. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  12. A statistical evaluation of the radionuclide inventory in the 222-S Laboratory and a comparison with the current inventory estimates

    International Nuclear Information System (INIS)

    Painter, C.L.; Daly, D.S.; Welsh, T.L.

    1996-09-01

    Department of Energy contractors responsible for the safe operation of non-reactor nuclear facilities need to establish maximum inventory limits on both radioactive and hazardous materials stored, used, or processed at their facilities. These contractors need to ensure that established maximum limits are not exceeded. This necessity is derived from the requirement to demonstrate that a non-reactor facility can by safely operated during normal and abnormal conditions. The 222-S Laboratory has established that a maximum of 800 core equivalent samples (CES)may be stored at the Laboratory. Using the CES definition one can determine the maximum allowed curies pre radionuclide permitted. These estimates were made using a variation on a statistical technique called smoothed-bootstrapping. Smoothed- bootstrapping is a method analogous to Monte Carlo simulation using a smoothed empirical probability distribution. This report discusses the application of the smoothed bootstrap technique to predicting the curie inventory retained in the numerous waste tank samples for the radionuclides of concern and the uncertainty associated with such a prediction

  13. Comparison of activity measurements of 131I and 99mTc radionuclides administered in nuclear medicine services of Porto Alegre

    International Nuclear Information System (INIS)

    Alabarse, Frederico Gil.; Santos, Carlos Eduardo Lima dos

    2005-01-01

    A programme for the comparison of activity measurements of radionuclides administered to patients in Nuclear Medicine Services, for the purpose of diagnosis or therapy, is being conducted under the coordination of the Radioprotection and Dosimetry Institute of the Brazilian Nuclear Energy Commission, IRD/CNEN. In the present work, measurements of the activity of samples of 131 I and 99 mTc were conducted in the dose calibrators of the Nuclear Medicine Services of the city of Porto Alegre, in the period from June to September 2004. The results were analysed to evaluate the compliance with the Brazilian regulation and were also compared to data available in the literature for the cities of Rio de Janeiro and Brasilia. The performance of the activity meters in Porto Alegre is shown to be very good, which contributes to the radiological protection of patients submitted to diagnosis or therapy with radiopharmaceuticals. (author)

  14. Radionuclide study for cardiac lesion in Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Oguni, Hirokazu; Osawa, Makiko; Shishikura, Keiko

    1985-12-01

    Tl-201 myocardial scintigraphy and radionuclide ventriculography with Tc-99m were performed in 10 patients with Duchenne muscular dystropohy (DMD) and 2 siblings with Becker muscular dystrophy (BMD). Perfusion defect especially in the left ventricular posterolateral wall (LVPLW) and cardiac apex was seen on Tl-201 imaging in 6 of the DMD patients and one of the BMD patients. For these patients, Tc-99m imaging also showed left ventricular local wall motion abnormality in 5 patients and a decreased left ventricular ejection fraction in 4 patients. These findings coincided well with fibrosis of the LVPLW found on autopsy. There were individual differences regarding the occurrence of cardiac complications. One of the BMD patients, as well as DMD patients, had also cardiac complications which have long been considered less common. (Namekawa, K.).

  15. Radionuclide study for cardiac lesion in Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Oguni, Hirokazu; Osawa, Makiko; Shishikura, Keiko

    1985-01-01

    Tl-201 myocardial scintigraphy and radionuclide ventriculography with Tc-99m were performed in 10 patients with Duchenne muscular dystropohy (DMD) and 2 siblings with Becker muscular dystrophy (BMD). Perfusion defect especially in the left ventricular posterolateral wall (LVPLW) and cardiac apex was seen on Tl-201 imaging in 6 of the DMD patients and one of the BMD patients. For these patients, Tc-99m imaging also showed left ventricular local wall motion abnormality in 5 patients and a decreased left ventricular ejection fraction in 4 patients. These findings coincided well with fibrosis of the LVPLW found on autopsy. There were individual differences regarding the occurrence of cardiac complications. One of the BMD patients, as well as DMD patients, had also cardiac complications which have long been considered less common. (Namekawa, K.)

  16. Equilibrium radionuclide assessment of left ventricular ejection and filling. Comparison of list mode-and multigated frame-mode measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; McKenna, W.J.; Dickie, S.; Oakley, C.M.; Myers, M.J.; Lavender, J.P. (Royal Postgraduate Medical School, London (UK))

    1983-10-01

    The relationship as studied between radionuclide indices of left ventricular systolic and diastolic function acquired in conventional multigated frame-mode compared to list-mode in patients with sinus rhythm. The study showed that frame-mode and list-mode measurements of ejection and filling indices are not significantly different in these patients but that backward reformatting of data acquired in list-mode is necessary to measure the atrial contribution to LV stroke counts. It was concluded that valid measurements of left ventricular systolic ejection and diastolic filling can be made in patients in sinus rhythm using frame-mode acquisition with the exception of measurements of the contribution from atrial systole to stroke volume.

  17. A comparison of models to assess the atmospheric dispersion of resuspended radionuclides on the Nevada Test Site

    International Nuclear Information System (INIS)

    Green, J.R.; Eckart, R.E.

    1994-11-01

    A study of computer codes was made to determine the suitability of their use for modeling radionuclide dispersion from attachment to fugitive dust at the GMX safety shot area of the Nevada Test site. Two codes, the Industrial Source Complex 2 Long Term Model (ISCLT2) and the Fugitive Dust Model (FDM), were subsequently chosen to model the GMX site. Dose calculations were performed using the output values generated by the computer codes. The concentration values produced by the two codes were within a factor of two of each other and were not significantly different. The FDM, however, was felt to be a more useful code for use in calculating doses caused by attachment to fugitive dust

  18. Radionuclide examinations

    International Nuclear Information System (INIS)

    Lentle, B.C.

    1989-01-01

    This paper reports on radionuclide examinations of the pancreas. The pancreas, situated retroperitonally high in the epigastrium, was a particularly difficult organ to image noninvasively before ultrasonography and computed tomography (CT) became available. Indeed the organ still remains difficult to examine in some patients, a fact reflected in the variety of methods available to evaluate pancreatic morphology. It is something of a paradox that the pancreas is metabolically active and physiologically important but that its examination by radionuclide methods has virtually ceased to have any role in day-to-day clinical practice. To some extent this is caused by the tendency of the pancreas's commonest gross diseases emdash carcinoma and pancreatitis, for example emdash to result in nonfunction of the entire organ. Disorders of pancreatic endocrine function have generally not required imaging methods for diagnosis, although an understanding of diabetes mellitus and its nosology has been advanced by radioimmunoassay of plasma insulin concentrations

  19. Critical evaluation of the Laboratory of Radionuclide Metrology results of the Institute of Radiation Protection and Dosimetry - IRD in the international key comparisons of activity measurement of radioactive solutions

    International Nuclear Information System (INIS)

    Iwahara, A.; Tauhata, L.; Silva, C.J. da

    2014-01-01

    The Radionuclide Metrology Laboratory (LMR) of LNMRI/IRD has been participating since 1984, in international key-comparisons of activity measurement of radioactive sources organized by BIPM and the Regional Metrology Organizations as EURAMET and APMP. The measured quantity is the activity of a radioactive solution, in becquerel (Bq), containing the radionuclide involved and the of measurement methods used are 4αβ-γ coincidence/anticoincidence, coincidence sum-peak and liquid scintillation. In this paper a summary of the methods used and a performance analysis of the results obtained are presented. (author)

  20. Radionuclide transfer

    International Nuclear Information System (INIS)

    Gerber, G.B.

    1993-01-01

    The research project described here had the aim to obtain further information on the transfer of nuclides during pregnancy and lactation. The tests were carried out in mini-pigs and rats receiving unchanging doses of radionuclides with the food. The following findings were revealed for the elements examined: Fe, Se, Cs and Zn were characterized by very high transfer levels in the mother, infant and foetus. A substantial uptake by the mother alone was observed for Co, Ag and Mn. The uptake by the foetus and infant here was 1 to 10 times lower. A preferential concentration in certain tissues was seen for Sr and Tc; the thyroid levels of Tc were about equally high in mothers and infants, while Sr showed less accumulation in the maternal bone. The lanthanide group of substances (Ce, Eu and Gd as well as Y and Ru) were only taken up to a very limited extent. The uptake of the examined radionuclides (Fe, Co, Ag, Ce) with the food ingested was found here to be ten times greater in rats as compared to mini-pigs. This showed that great caution must be observed, if the behaviour of radionuclides in man is extrapolated from relevant data obtained in rodents. (orig./MG) [de

  1. Characteristics of 201Tl myocardial SPECT and left ventriculography in patients with acute diagonal branch myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Aizawa, Tadanori; Katou, Kazuzo; Ogasawara, Ken; Kirigaya, Hajime

    1993-01-01

    Characteristics of 201 Tl myocardial SPECT and ventriculography were studied in 13 patients with acute diagonal branch myocardial infarction. Rest 201 Tl myocardial SPECT and left ventriculography were underwent in chronic phase. In 5 patients electrocardiogram (ECG) changes in acute phase were not definite. In 6 patients it was difficult to identify the obstructed coronary artery with coronary angiography in acute phase. Mean value of maximum creatine phosphokinese (CPK) was 854 (458-1,774) U/l. It seemed to be difficult to diagnose acute diagonal branch myocardial infarction with ECG and/or coronary angiography. In all patients defects were noted on 201 Tl SPECT. Defects were small and noted in the central anterior wall and not in the septum. In 2 patients defects were noted at apex. In left ventriculography dyskinetic motion was noted in 10 patients; one patient showed apical aneurysm and 3 patients showed anterior wall aneurysm. In 3 patients anterior wall showed akinesis. It was concluded that 201 Tl myocardial SPECT were useful for detecting diagonal branch lesion. In case of diagonal branch myocardial infarction size of defects were small and defects were not noted in the septum, however aneurysmal motion was frequently noted. (author)

  2. Right-ventricular and left-ventricular function parameters in patients with and without outflow tract patches as determined by radionuclide methods at least 10 years following surgical correction of Fallot's tetralogy in the adult individuals

    International Nuclear Information System (INIS)

    Seidel, P.

    1988-01-01

    During a period starting in 1983 and ending in April 1984 radionuclide ventriculography was performed in 26 patients subjected to surgical correction of Fallot's tetralogy after having reached adulthood. They were divided into two groups according to the surgical methods used. Patients showing no right-ventricular outflow patch were assigned to group I, while group II was made up of individuals that had received outflow tract patches of Dacron or Teflon for pressure reduction in the right ventricle. The parameters registered during radionuclide ventriculography, in which the tracer substance TC 99m was administered into a peripheral vein, included the endiastolic volume, endsystolic volume, stroke volume, global ejection fraction and cardiac index. For resting patients, these values were calculated using the first-pass technique, the determinations during exercise on the ergometer were based on equilibrium radionuclide ventriculography. It could be concluded from the results obtained here that non-invasive endocardial scintigraphy is a sensitive method that can be used both at rest and during exercise on the ergometer to detect function disorders of the right and left ventricles. (orig./MG) [de

  3. Determination of left ventricular volume using gated blood pool tomography comparison with contrast ventriculography

    International Nuclear Information System (INIS)

    Lu Ping; Mo Lijun; Liu Xiujie

    1992-01-01

    48 patients with cardiac disease were studied with gated blood pool tomography to determine left ventricular volume at end diastole, end-systole and ejection fraction. The volumes were calculated from serial short-axis tomograms by multiplying the number of pixels and the known volume of each pixel. Excellent correlation was found between blood pool tomography and contrast ventriculographic volume. At end-diastole, r = 0.91 (P < 0.01); at end-systole, r = 0.95 (P < 0.01); for left ventricular ejection fraction, r 0.90 (P < 0.01). The results suggest that gated blood pool tomography is a promising noninvasive and direct method for measuring left ventricular volume

  4. Comparisons between a new point kernel-based scheme and the infinite plane source assumption method for radiation calculation of deposited airborne radionuclides from nuclear power plants.

    Science.gov (United States)

    Zhang, Xiaole; Efthimiou, George; Wang, Yan; Huang, Meng

    2018-04-01

    Radiation from the deposited radionuclides is indispensable information for environmental impact assessment of nuclear power plants and emergency management during nuclear accidents. Ground shine estimation is related to multiple physical processes, including atmospheric dispersion, deposition, soil and air radiation shielding. It still remains unclear that whether the normally adopted "infinite plane" source assumption for the ground shine calculation is accurate enough, especially for the area with highly heterogeneous deposition distribution near the release point. In this study, a new ground shine calculation scheme, which accounts for both the spatial deposition distribution and the properties of air and soil layers, is developed based on point kernel method. Two sets of "detector-centered" grids are proposed and optimized for both the deposition and radiation calculations to better simulate the results measured by the detectors, which will be beneficial for the applications such as source term estimation. The evaluation against the available data of Monte Carlo methods in the literature indicates that the errors of the new scheme are within 5% for the key radionuclides in nuclear accidents. The comparisons between the new scheme and "infinite plane" assumption indicate that the assumption is tenable (relative errors within 20%) for the area located 1 km away from the release source. Within 1 km range, the assumption mainly causes errors for wet deposition and the errors are independent of rain intensities. The results suggest that the new scheme should be adopted if the detectors are within 1 km from the source under the stable atmosphere (classes E and F), or the detectors are within 500 m under slightly unstable (class C) or neutral (class D) atmosphere. Otherwise, the infinite plane assumption is reasonable since the relative errors induced by this assumption are within 20%. The results here are only based on theoretical investigations. They should

  5. Comparison of the effectiveness of various procedures for the rejection of outlying results and assigning consensus values in interlaboratory programs involving determination of trace elements or radionuclides

    International Nuclear Information System (INIS)

    Dybczynski, R.

    1980-01-01

    Rejection of outlying results is usually necessary in the evaluation of interlaboratory comparisons, especially those involving trace elements and low-level activity measurements. The performance of several criteria (Dixon's test, Grubbs' test, coefficient of skewness test, and coefficient of kurtosis test) is described; authentic data sets from intercomparison runs on trace element or radionuclide determinations in spiked samples are used. The existence of 'masking effects' in certain cases is demonstrated. It is shown that concurrent use of all four criteria at small (0.01) or moderate (0.05) significance levels gives better results than the use of any single test. The use of all four criteria at α = 0.05 followed by calculation of overall mean and pertinent confidence limits is suggested as a general method of data handling in interlaboratory comparison. This method normally ensures good selectivity of outlier rejection while avoiding excessive rejections, and results in generally good agreement between the 'true' value and the final overall mean. The use of this approach for the establishment of recommended values in candidate reference materials is demonstrated and its advantages and limitations are discussed. The results are further compared with those obtained by other methods of data evaluation (Student's test, dominant cluster mode and gamma transformation). (Auth.)

  6. Transfer coefficients of selected radionuclides to animal products. I. Comparison of milk and meat from dairy cows and goats

    International Nuclear Information System (INIS)

    Johnson, J.E.; Ward, G.M.; Ennis, M.E. Jr.; Boamah, K.N.

    1988-01-01

    The diet-milk transfer coefficient, Fm (Bq L-1 output in milk divided by Bq d-1 intake to the animal) was studied for eight radionuclides that previously had been given little attention. The Fm values for cows and goats, respectively, were: 2.3 x 10(-5) and 1.5 x 10(-4) for /sup 99m/Tc, 1.4 x 10(-4) and 8.5 x 10(-4) for /sup 95m/Tc, 1.1 x 10(-2) for 99 Tc (goats only); 1.7 x 10(-3) and 9 x 10(-3) for 99 Mo; 4.8 x 10(-4) and 4.4 x 10(-3) for /sup 123m/Te; 4.8 x 10(-4) and 4.6 x 10(-3) for 133 Ba; 5.5 x 10(-7) and 5.5 x 10(-6) for 95 Zr; and 4.1 x 10(-7) and 6.4 x 10(-6) for 95 Nb. The goat/cow transfer coefficient ratios for milk were approximately 10, but the goat/cow ratios for meat varied by three orders of magnitude

  7. Comparison between MAAP and ECART predictions of radionuclide transport throughout a French standard PWR reactor coolant system

    International Nuclear Information System (INIS)

    Hervouet, C.; Ranval, W.; Parozzi, F.; Eusebi, M.

    1996-04-01

    In the framework of a collaboration agreement between EDF and ENEL, the MAAP (Modular Accident Analysis Program) and ECART (ENEL Code for Analysis of radionuclide Transport) predictions about the fission product retention inside the reactor cooling system of a French PWR 1300 MW during a small Loss of Coolant Accident were compared. The volatile fission products CsI, CsOH, TeO 2 and the structural materials, all of them released early by the core, are more retained in MAAP than in ECART. On the other hand, the non-volatile fission products, released later, are more retained in ECART than in MAAP, because MAAP does not take into account diffusion-phoresis: in fact, this deposition phenomenon is very significant when the molten core vaporizes the water of the vessel lower plenum. Centrifugal deposition in bends, that can be modeled only with ECART, slightly increases the whole retention in the circuit if it is accounted for. (authors). 18 refs., figs., tabs

  8. Radionuclide radiology

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Graham, R.N.J.; Perriss, R.W.; Bradley, K.M.

    2006-01-01

    This is the fourth in a series of short reviews of internet-based radiological educational resources, and will focus on radionuclide radiology and nuclear medicine. What follows is a list of carefully selected websites to save time in searching them out. Most of the sites cater for trainee or non-specialist radiologists, but may also be of interest to specialists for use in teaching. This article may be particularly useful to radiologists interested in the rapidly expanding field of positron emission tomography computed tomography (PET-CT). Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (February 2006)

  9. Drift-Scale Radionuclide Transport

    International Nuclear Information System (INIS)

    Houseworth, J.

    2004-01-01

    The purpose of this model report is to document the drift scale radionuclide transport model, taking into account the effects of emplacement drifts on flow and transport in the vicinity of the drift, which are not captured in the mountain-scale unsaturated zone (UZ) flow and transport models ''UZ Flow Models and Submodels'' (BSC 2004 [DIRS 169861]), ''Radionuclide Transport Models Under Ambient Conditions'' (BSC 2004 [DIRS 164500]), and ''Particle Tracking Model and Abstraction of Transport Process'' (BSC 2004 [DIRS 170041]). The drift scale radionuclide transport model is intended to be used as an alternative model for comparison with the engineered barrier system (EBS) radionuclide transport model ''EBS Radionuclide Transport Abstraction'' (BSC 2004 [DIRS 169868]). For that purpose, two alternative models have been developed for drift-scale radionuclide transport. One of the alternative models is a dual continuum flow and transport model called the drift shadow model. The effects of variations in the flow field and fracture-matrix interaction in the vicinity of a waste emplacement drift are investigated through sensitivity studies using the drift shadow model (Houseworth et al. 2003 [DIRS 164394]). In this model, the flow is significantly perturbed (reduced) beneath the waste emplacement drifts. However, comparisons of transport in this perturbed flow field with transport in an unperturbed flow field show similar results if the transport is initiated in the rock matrix. This has led to a second alternative model, called the fracture-matrix partitioning model, that focuses on the partitioning of radionuclide transport between the fractures and matrix upon exiting the waste emplacement drift. The fracture-matrix partitioning model computes the partitioning, between fractures and matrix, of diffusive radionuclide transport from the invert (for drifts without seepage) into the rock water. The invert is the structure constructed in a drift to provide the floor of the

  10. Cardiac involvement of progressive muscular dystrophy (Becker type, Limb-girdle type and Fukuyama type) evaluated by radionuclide method

    International Nuclear Information System (INIS)

    Nagamachi, Shigeki; Inoue, Kenjiro; Jinnouchi, Seishi; Hoshi, Hiroaki; Ono, Seiji; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Hayashi, Tohru

    1994-01-01

    Tl-201 SPECT and Tc-99m-Human serum albumin (HSA) multigated radionuclide ventriculography were performed on 11 patients with progressive muscular dystrophy (Becker type 2, Fukuyama type 2, Limb-girdle type 7) to evaluate myocardial involvement. Hypoperfusion was detected in 8 patients on Tl-201 SPECT. Decreases in both systolic function (left ventricular ejection fraction; LVEF) and diastolic function (peak filling rate; PFR) were also seen in these patients. A high incidence of myocardial involvement of these kinds of progressive muscular dystrophy was suggested. (author)

  11. Cardiac involvement of progressive muscular dystrophy (Becker type, Limb-girdle type and Fukuyama type) evaluated by radionuclide method

    Energy Technology Data Exchange (ETDEWEB)

    Nagamachi, Shigeki; Inoue, Kenjiro; Jinnouchi, Seishi; Hoshi, Hiroaki; Ono, Seiji; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Hayashi, Tohru [Miyazaki Medical Coll., Kiyotake (Japan)

    1994-02-01

    Tl-201 SPECT and Tc-99m-Human serum albumin (HSA) multigated radionuclide ventriculography were performed on 11 patients with progressive muscular dystrophy (Becker type 2, Fukuyama type 2, Limb-girdle type 7) to evaluate myocardial involvement. Hypoperfusion was detected in 8 patients on Tl-201 SPECT. Decreases in both systolic function (left ventricular ejection fraction; LVEF) and diastolic function (peak filling rate; PFR) were also seen in these patients. A high incidence of myocardial involvement of these kinds of progressive muscular dystrophy was suggested. (author).

  12. Transverse comparisons between ultrasound and radionuclide parameters in children with presumed antenatally detected pelvi-ureteric junction obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Duong, Hong Phuoc; Janssen, Francoise; Hall, Michelle; Ismaili, Khalid [Universite Libre de Bruxelles (ULB), Department of Pediatric Nephrology, Hopital Universitaire des Enfants Reine Fabiola, Brussels (Belgium); Piepsz, Amy [Hopital Universitaire Saint-Pierre, Department of Radioisotopes, Ghent (Belgium); Khelif, Karim; Collier, Frank [Universite Libre de Bruxelles (ULB), Department of Pediatric Urology, Hopital Universitaire des Enfants Reine Fabiola, Brussel (Belgium); Man, Kathia de [University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium); Damry, Nash [Universite Libre de Bruxelles (ULB), Department of Pediatric Radiology, Hopital Universitaire des Enfants Reine Fabiola, Brussel (Belgium)

    2015-05-01

    The main criteria used for deciding on surgery in children with presumed antenatally detected pelviureteric junction obstruction (PPUJO) are the level of hydronephrosis (ultrasonography), the level of differential renal function (DRF) and the quality of renal drainage after a furosemide challenge (renography), the importance of each factor being far from generally agreed. Can we predict, on the basis of ultrasound parameters, the patient in whom radionuclide renography can be avoided? We retrospectively analysed the medical charts of 81 consecutive children with presumed unilateral PPUJO detected antenatally. Ultrasound and renographic studies performed at the same time were compared. Anteroposterior pelvic diameter (APD) and calyceal size were both divided into three levels of dilatation. Parenchymal thickness was considered either normal or significantly decreased. Acquisition of renograms under furosemide stimulation provided quantification of DRF, quality of renal drainage and cortical transit. The percentages of patients with low DRF and poor drainage were significantly higher among those with major hydronephrosis, severe calyceal dilatation or parenchymal thinning. Moreover, impaired cortical transit, which is a major risk factor for functional decline, was seen more frequently among those with very severe calyceal dilatation. However, none of the structural parameters obtained by ultrasound examination was able to predict whether the level of renal function or the quality of drainage was normal or abnormal. Alternatively, an APD <30 mm, a calyceal dilatation of <10 mm and a normal parenchymal thickness were associated with a low probability of decreased renal function or poor renal drainage. In the management strategy of patients with prenatally detected PPUJO, nuclear medicine examinations may be postponed in those with an APD <30 mm, a calyceal dilatation of <10 mm and a normal parenchymal thickness. On the contrary, precise estimation of DRF and renal

  13. Numerical modelling and parametric study of the atmospheric dispersion after radionuclide releases: the Chernobyl accident and the Algeciras incident. Comparison with observation data

    International Nuclear Information System (INIS)

    Minier, Y.; Mathieu, A.; Quelo, D.; Sportisse, B.; Isnard, O.; Krysta, M.; Bocquet, M.

    2006-01-01

    Full text: The attempts of modelling the release following upon the Chernobyl accident and the Algeciras incident are reported. Computing power and observation database are used for sensitivity and parametric studies. The meteorological mesoscale model MM5 is nudged with the ERA-40 reanalysis to simulate the meteorological conditions used by the dispersion model, POLAIR3D. In case of the Chernobyl accident the points of interest are many: the representativity of the meteorological simulations is evaluated using observations with a special focus on precipitation events. The radionuclide dispersion, the dry deposition and scavenging simulated by POLAIR3D are compared with European measurements of activities and depositions. Results of the sensitivity studies are done to evaluate the impact of the deposition parameterizations and source-term characteristics (height of release, quantities). The time dynamic of the contaminated cloud is also investigated with regard to the arrival time on different countries. Similarly, for the Algeciras release, sensitivity to the meteorological fields, source term and depletion processes are analyzed. For the available activity concentrations in the air, data-model comparisons are performed. (author)

  14. Selective coronarography and ventriculography with Iopamidol in the acute phase of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ricci Maccarini, P; Benenati, P M; Bellanti, G; Piscitelli, G

    1988-01-01

    The new techniques for an early treatement of acute myocardial infarction (AMI), such as thrombolysis and percutaneous transluminal angioplasty, often necessitate rapid and accurate radiological evaluation of coronaric lesions and left ventricular function. The aim of the present study was to evaluate both safety and tolerability of selective coronarography (SC) and left ventriculography (LVG), with iopamidol 370 mg I/ml as a contrast medium, in the acute phase of AMI. Thirty-nine patients aged 26-29 years, were examined: 18 group A, within 4 days (mean 2.6+-0.8 SD) and 21, group B, within 5-15 days after AMI (mean 8.8+-3 SD). Contrast media (cm) dosage varied from 150 to 300 ml (2.43-5.5 ml/bw). During the procedure, ECG was continuosly recorded; left ventricular pressure was registered immediately and 30 minutes after cm administration. During the following 9 days ECG tracings and plasmatic cytolysisenzymes were monitored. During the examination no patient complained of any symptoms. After LVG slight elevations in end diastolic pressure were detected in all patients (mean increase 4.7 mmHg), which were not relevant from a clinical point of view. In 11/39 cases ventricular tachycardia was observed, which spontaneously ceased. During SC no change in ECG tracings was registered except in one patient, group A, in whom complete transitory heart block was detected. After SC no alteration in instrumental and biochemical parameters was registered except in one patient, group B, in whom a reinfarction due to right coronaric artery occlusion was observed. In conclusion, these results suggest that both SC and LVG with iopamidol are safe techniques also in the early phase of myocardial infarction. 24 refs.

  15. Comparison of predictions from internationally recognized assessment models for the transfer of selected radionuclides through terrestrial food chains

    International Nuclear Information System (INIS)

    Hoffman, F.O.; Bergstroem, U.; Gyllander, C.; Wilkens, A.B.

    1984-01-01

    Six internationally recognized terrestrial food-chain models developed in Sweden, the United States, the United Kingdom, the Federal Republic of Germany, and the International Atomic Energy Agency are compared. This comparison includes the data bases and predictions for the transfer of Co-60, Sr-90, I-131, and Cs-137 into milk, and leafy and nonleafy vegetables from a hypothetical 30-yr continuous rate of atmospheric deposition onto agricultural systems. Model predictions are compared against United Nations summaries of empirical relationships between atmospheric deposition and concentrations in food of Sr-90 and Cs-137. The results of statistical analyses of the effect of parameter uncertainties on model predictions are also included for Sr-90, Cs-137, and I-131. Discrepancies among model predictions vary between factors of 6 and 30. These results reflect differences in model assumptions rather than uncertainties in model parameters

  16. Evaluation of degree of readsorption of radionuclides during sequential extraction in soil: comparison between batch and dynamic extraction systems

    DEFF Research Database (Denmark)

    Petersen, Roongrat; Hansen, Elo Harald; Hou, Xiaolin

    . However, the techniques have an important problem with redistribution as a result of readsorption of dissolved analytes onto the remaining solids phases during extraction. Many authors have demonstrated the readsorption problem and inaccuracy from it. In our previous work, a dynamic extraction system......Sequential extraction techniques have been widely used to fractionate metals in solid samples (soils, sediments, solid wastes, etc.) due to their leachability. The results are useful for obtaining information about bioavailability, potential mobility and transport of element in natural environments...... developed in our laboratory for heavy metal fractionation has shown the reduction of readsorption problem in comparison with the batch techniques. Moreover, the system shows many advantages over the batch system such as speed of extraction, simple procedure, fully automatic, less risk of contamination...

  17. Clinical evaluation of Tc-99m-mebrofenin and comparison with Tc-disofenin for radionuclide hepatobiliary imaging

    International Nuclear Information System (INIS)

    Klingensmith, W. III; Fritzberg, A.; Spitzer, V.

    1982-01-01

    The clinical comparison reported indicates that Tc-mebrofenin has a significantly lower level of renal excretion that Tc-disofenin at all bilirubin levels. At a total bilirubin level of 25 mg/dl the renal excretion of Tc-mebrofenin is still less than the renal excretion of Tc-disofenin in subjects with normal bilirubin levels. In addition, renal radioactivity in images was never seen in subjects with normal bilirubins while visualization of renal radioactivity is routine in normal subjects with Tc-disofenin. No significant differences were found in any other parameter including hepatocyte extraction efficiency, time of maximum hepatic radioactivity, and hepatic parenchymal washout. This study indicates that Tc-mebrofenin is equal to Tc-disofenin in its hepatobiliary characteristics and superior in its renal characteristics

  18. Radionuclide stroke count ratios for assessment of right and left ventricular volume overload in children

    International Nuclear Information System (INIS)

    Parrish, M.D.; Graham, T.P. Jr.; Born, M.L.; Jones, J.P.; Boucek, R.J. Jr.; Artman, M.; Partain, C.L.

    1983-01-01

    The ratio of left ventricular to right ventricular stroke counts measured by radionuclide angiography has been used in adults to estimate the severity of left-sided valvular regurgitation. The validation of this technique in children for assessment of right and left ventricular volume overload is reported herein. Radionuclide stroke count ratios in 60 children aged 0.5 to 19 years (mean 11) were determined. Based on their diagnoses, the patients were divided into 3 groups: (1) normal--40 patients with no shunts or valvular regurgitation, (2) left ventricular volume overload--13 patients with mitral or aortic regurgitation, or both, and (3) right ventricular volume overload--7 patients, 2 with severe tricuspid regurgitation, 3 with atrial septal defects, and 2 with total anomalous pulmonary venous drainage. The radionuclide stroke count ratio clearly differentiated these groups (p less than 0.05): normal patients had a stroke count ratio of 1.04 +/- 0.17 (mean +/- 1 standard deviation), the left ventricular volume overload group had a stroke count ratio of 2.43 +/- 0.86, and the right ventricular volume overload group had a stroke count ratio of 0.44 +/- 0.17. In 22 of our 60 patients, radionuclide stroke count ratios were compared with cineangiographic stroke volume ratios, resulting in a correlation coefficient of 0.88. It is concluded that radionuclide ventriculography is an excellent tool for qualitative and quantitative assessment of valvular regurgitation in children

  19. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  20. Gastroesophageal reflux in children: radionuclide gastroesophagography

    International Nuclear Information System (INIS)

    Blumhagen, J.D.; Rudd, T.G.; Christie, D.L.

    1980-01-01

    Sixty-five symptomatic infants and children underwent radionuclide gastroesophagography, acid reflux testing, and barium esophagography with water-siphon testing to evaluate the clinical efficacy of the scintigraphic technique in detecting gastroesophageal reflux. After ingesting /sup 99m/Tc sulfur colloid in fruit juice, patients rested beneath the gamma camera for 30 to 60 min while esophageal activity was monitored continuously. By using the acid reflux test as a standard of comparison, the senstivity of radionuclide gastroesophagography was 75%. Because of its physiologic nature, low radiation exposure, and convenience, radionuclide gastroesophagography warrants further evaluation as a screening test for gastroesophageal reflux

  1. Right-ventricular and left-ventricular function parameters in patients with and without outflow tract patches as determined by radionuclide methods at least 10 years following surgical correction of Fallot's tetralogy in the adult individuals. Nuklearmedizinische Bestimmung der rechts- und linksventrikulaeren Funktionsparameter von Patienten ohne und mit Ausflusstraktpatch - mindestens 10 Jahre nach operativer Korrektur der Fallot'schen Tetralogie im Erwachsenenalter

    Energy Technology Data Exchange (ETDEWEB)

    Seidel, P.

    1988-12-15

    During a period starting in 1983 and ending in April 1984 radionuclide ventriculography was performed in 26 patients subjected to surgical correction of Fallot's tetralogy after having reached adulthood. They were divided into two groups according to the surgical methods used. Patients showing no right-ventricular outflow patch were assigned to group I, while group II was made up of individuals that had received outflow tract patches of Dacron or Teflon for pressure reduction in the right ventricle. The parameters registered during radionuclide ventriculography, in which the tracer substance TC 99m was administered into a peripheral vein, included the endiastolic volume, endsystolic volume, stroke volume, global ejection fraction and cardiac index. For resting patients, these values were calculated using the first-pass technique, the determinations during exercise on the ergometer were based on equilibrium radionuclide ventriculography. It could be concluded from the results obtained here that non-invasive endocardial scintigraphy is a sensitive method that can be used both at rest and during exercise on the ergometer to detect function disorders of the right and left ventricles. (orig./MG).

  2. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Allen, S.E.; Horrill, A.D.; Howard, B.J.; Lowe, V.P.W.; Parkinson, J.A.

    1983-07-01

    The subject is discussed under the headings: concentration and spatial distribution of radionuclides in grazed and ungrazed saltmarshes; incorporation of radionuclides by sheep grazing on an estuarine saltmarsh; inland transfer of radionuclides by birds feeding in the estuaries and saltmarshes at Ravenglass; radionuclides in contrasting types of coastal pastures and taken up by individual plant species found in west Cumbria; procedures developed and used for the measurement of alpha and gamma emitters in environmental materials. (U.K.)

  3. Quantitation of aortic and mitral regurgitation in the pediatric population: evaluation by radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Hurwitz, R.A.; Treves, S.; Freed, M.; Girod, D.A.; Caldwell, R.L.

    1983-01-01

    The ability to quantitate aortic (AR) or mitral regurgitation (MR), or both, by radionuclide angiocardiography was evaluated in children and young adults at rest and during isometric exercise. Regurgitation was estimated by determining the ratio of left ventricular stroke volume to right ventricular stroke volume obtained during equilibrium ventriculography. The radionuclide measurement was compared with results of cineangiography, with good correlation between both studies in 47 of 48 patients. Radionuclide stroke volume ratio was used to classify severity: the group with equivocal regurgitation differed from the group with mild regurgitation (p less than 0.02); patients with mild regurgitation differed from those with moderate regurgitation (p less than 0.001); and those with moderate regurgitation differed from those with severe regurgitation (p less than 0.01). The stroke volume ratio was responsive to isometric exercise, remaining constant or increasing in 16 of 18 patients. After surgery to correct regurgitation, the stroke volume ratio significantly decreased from preoperative measurements in all 7 patients evaluated. Results from the present study demonstrate that a stroke volume ratio greater than 2.0 is compatible with moderately severe regurgitation and that a ratio greater than 3.0 suggests the presence of severe regurgitation. Thus, radionuclide angiocardiography should be useful for noninvasive quantitation of AR or MR, or both, helping define the course of young patients with left-side valvular regurgitation

  4. The role of multiple regression and exploratory data analysis in the development of leukemia incidence risk models for comparison of radionuclide air stack emissions from nuclear and coal power industries

    International Nuclear Information System (INIS)

    Prybutok, V.R.

    1995-01-01

    Risk associated with power generation must be identified to make intelligent choices between alternate power technologies. Radionuclide air stack emissions for a single coal plant and a single nuclear plant are used to compute the single plant leukemia incidence risk and total industry leukemia incidence risk. Leukemia incidence is the response variable as a function of radionuclide bone dose for the six proposed dose response curves considered. During normal operation a coal plant has higher radionuclide emissions than a nuclear plant and the coal industry has a higher leukaemia incidence risk than the nuclear industry, unless a nuclear accident occurs. Variation of nuclear accident size allows quantification of the impact of accidents on the total industry leukemia incidence risk comparison. The leukemia incidence risk is quantified as the number of accidents of a given size for the nuclear industry leukemia incidence risk to equal the coal industry leukemia incidence risk. The general linear model is used to develop equations that relate the accident frequency required for equal industry risks to the magnitude of the nuclear emission. Exploratory data analysis revealed that the relationship between the natural log of accident number versus the natural log of accident size is linear. (Author)

  5. Comparison on the production of radionuclides in 1.4 GeV proton irradiated LBE targets of different thickness

    CERN Document Server

    Maiti, Moumita; Mendonça, Tania M; Stora, Thierry; Lahiri, Susanta

    2014-01-01

    This is the first report on the inventory of radionuclides produced in 1.4 GeV proton induced reaction on Lead-Bismuth Eutectic (LBE) targets. LBE targets of 6 mm diameter and 1 to 8 mm lengths were irradiated with 1.4 GeV protons. The radionuclides ranging from Be-7 (53.12 days) to Po-207 (5.8 h) were identified in the samples with the help of time resolved gamma-ray spectroscopy. However, there is no signature of formation of At radioisotopes, which can be produced by the interaction of secondary particles, typical for thick targets.

  6. Comparison of the analytical methods used to determine natural and artificial radionuclides from environmental samples by gamma, alpha and beta spectrometry

    DEFF Research Database (Denmark)

    Pöllänen, Roy; Virtanen, Sinikka; Kämäräinen, Meerit

    In CAMNAR, an extensive interlaboratory exercise on the analytical methods used to determine several radionuclides present in the environmental samples was organized. Activity concentration of different natural radionuclides, such as Rn-222, Pb-210, Po-210, K-40, Ra-226, Ra-228 and isotopes...... of uranium, in addition to artificial Cs-137 and Am-241 were analysed from lake sediment samples and drinking water. The measurement techniques were gamma-ray spectrometry, alpha spectrometry, liquid scintillation counting and inductively coupled plasma mass spectrometry. Twenty six laboratories from nine...

  7. Cerebrospinal fluid flow abnormalities in patients with neoplastic meningitis. An evaluation using 111In-DTPA ventriculography

    International Nuclear Information System (INIS)

    Grossman, S.A.; Trump, D.L.; Chen, D.C.; Thompson, G.; Camargo, E.E.

    1982-01-01

    Cerebrospinal fluid flow dynamics were evaluated by 111 In-diethylenetriamine pentaacetic acid ( 111 In-DTPA) ventriculography in 27 patients with neoplastic meningitis. Nineteen patients (70 percent) had evidence of cerebrospinal fluid flow disturbances. These occurred as ventricular outlet obstructions, abnormalities of flow in the spinal canal, or flow distrubances over the cortical convexities. Tumor histology, physical examination, cerebrospinal fluid analysis, myelograms, and computerized axial tomographic scans were not sufficient to predict cerebrospinal fluid flow patterns. These data indicate that cerebrospinal fluid flow abnormalities are common in patients with neoplastic meningitis and that 111 In-DTPA cerebrospinal fluid flow imaging is useful in characterizing these abnormalities. This technique provides insight into the distribution of intraventricularly administered chemotherapy and may provide explanations for treatment failure and drug-induced neurotoxicity in patients with neoplastic meningitis

  8. Comparison of extraction chromatography and a procedure based on the molecular recognition method as separation methods in the determination of neptunium and plutonium radionuclides

    International Nuclear Information System (INIS)

    Strisovska, Jana; Galanda, Dusan; Drabova, Veronika; Kuruc, Jozef

    2012-01-01

    The potential of various types of sorbents for separation of radionuclides of plutonium and neptunium were examined. Extraction chromatography and a procedure based on the molecular recognition method were used for the separation. The suitability of the various sorbent types and brands for this purpose was determined. (orig.)

  9. Assessment of function of the cardiovascular system in arterial hypertension using radionuclide methods of investigation

    International Nuclear Information System (INIS)

    Oganesyan, N.M.; Babayan, A.S.; Mikaehlyan, R.S.; Mnatsakyan, Eh.L.

    1986-01-01

    Proceeding from a study of the nature of changes in hemodynamics during development of hypertensive disease (HD) at its different stages it was shown that hemodynamic changes in 42.1% of the patients with Stage 1-2A HD were of hypertensive type, in the patients with Stage 2B-3 HD normal and hypokinetic types of the blood circulation prevailed. After bicycle ergometry exercise the reactivity of the cardiovascular system was revealed more completely. The most complete information on function of the cardiovascular system and myocardial contractility can be obtained with the help of radioangiocardiography and radionuclide ventriculography. However in the absence of a gamma-chamber radiocardiography can provide necessary information on function of the cardiovascular system in case it is used in one and the same patient over time using bicycle ergometry testing

  10. Factor analysis of radionuclide ejection fraction response during exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Yamamuro, Masashi

    1986-01-01

    In 204 patients with ischemic heart disease and 25 normal subjects who underwent exercise radionuclide ventriculography (RNV), multivariate analyses and other statistical methods were employed to study factors affecting changes in left ventricular ejection fraction (ΔEF). Twenty one variables were obtained from clinical diagnosis, cardiac catheterization, and RNV. Multivariate analyses showed that coronary score for the severity of coronary artery lesions was the most significant factor, followed by exercise duration, resting heart rate, the number of diseased vessels, and exercise heart rate. Statistically significant decrease in ΔEF was associated with regional wall motion abnormality, ECG changes, and chest pain. Lesions in the left main trunk and the proximal area of left anterior descending artery were greatly involved in the decrease of ΔEF. (Namekawa, K.)

  11. Measurement of absolute left ventricular volume by radionuclide angiography: a technical review

    International Nuclear Information System (INIS)

    Al-Khawaja, I.M.; Lahiri, Avijit; Raftery, E.B.; Medical Research Council, Harrow

    1988-01-01

    Absolute left ventricular volumes have important clinical implications in the evaluation of cardiac performance. Several invasive and noninvasive techniques have been reported, none of which can be considered ideal for this purpose. Contrast angiography, echocardiography and radionuclide ventriculography are open to criticism. Different radioisotopic approaches are described with emphasis on the importance of accurate separation of left ventricular activity, the selection of background activity, and the correction for photon attenuation by body tissues. Improper use of statistics and validation techniques have obscured the value of these techniques. In the absence of a 'gold standard' there should be a 'radioisotopic' left ventricular volume with established independent characteristics, repeatability and reproducibility by which new approaches can be judged. (author)

  12. Evaluation of right ventricular ejection fraction by first-pass radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Uehara, Toshiisa; Nishimura, Tsunehiko; Naito, Hiroaki; Hayashida, Kohei; Kozuka, Takahiro

    1981-01-01

    Left ventricular ejection fraction (LVEF) obtained by radionuclide angiocardiography is a convenient and good parameter of the left ventricular function. Right ventricular ejection fraction (RVEF) also seems to be a good parameter of the right ventricular function. RVEF calculated from volumetry with contrast right ventriculography is not necessarily correct because of the complex figure of the right ventricle. On the other hand, the method of calculation of RVEF with radionuclide angiocardiography has the advantage of being able to ignore the complexity of figure of RV, because RI counts extracted from the time-activity curve represent changes in ventricular volume. In this study, we developped an original method to calculate RVEF with first pass method. After setting of region of interest (ROI) of RV, background and ROI for correction of motion of tricuspid valve, we calculated RVEF with these time-activity curves, Since we found that too rapid infusion of RI made the time-activity curve of RV too steep, and too slow infusion of RI made the background of lung field too high, the appropriate infusion rate was required to get correct value of RVEF. In addition, the time-activity curve often became steep or flat in dependence of the speed of venous return and cardiac output of patients. In order to avoid the effect of infusion speed, the time-activity curve was fitted to linear curves and the value of RVEF was corrected. The validity of these methods was confirmed in our study. As the result, RVEF obtained with our methods appeared to have good correlation with that obtained from volumetry of contrast right ventriculography (r = 0.77) and to be very useful in clinical estimation of right ventricular function. (author)

  13. Speciation analysis of radionuclides

    International Nuclear Information System (INIS)

    Salbu, B.

    2010-01-01

    Full text: Naturally occurring and artificially produced radionuclides in the environment can be present in different physico-chemical forms (i. e. radionuclide species) varying in size (nominal molecular mass), charge properties and valence, oxidation state, structure and morphology, density, complexing ability etc. Low molecular mass (LMM) species are believed to be mobile and potentially bioavailable, while high molecular mass (HMM) species such as colloids, polymers, pseudocolloids and particles are considered inert. Due to time dependent transformation processes such as mobilization of radionuclide species from solid phases or interactions of mobile and reactive radionuclide species with components in soils and sediments, however, the original distribution of radionuclides deposited in ecosystems will change over time and influence the ecosystem behaviour. To assess the environmental impact from radionuclide contamination, information on radionuclide species deposited, interactions within affected ecosystems and the time-dependent distribution of radionuclide species influencing mobility and biological uptake is essential. The development of speciation techniques to characterize radionuclide species in waters, soils and sediments should therefore be essential for improving the prediction power of impact and risk assessment models. The present paper reviews fractionation techniques which should be utilised for radionuclide speciation purposes. (author)

  14. Radionuclide cinematography of the heart

    International Nuclear Information System (INIS)

    Adam, W.E.; Sigel, H.; Geffers, H.; Bitter, F.; Meyer, G.; Kampmann, H.; Stauch, M.

    1976-01-01

    Radionuclide cinematography is described as a procedure making use of radiation-level variations above the heart after equipartitioning of sup(99m)Tc-labelled human serum albumin in the blood pool. Regional ventricular and vestibular variations are phase-shifted. This procedure permits delineation of aneurysmas with interphasic course, cicatrization of the cardiac wall not producing any cyclical variation. The study included normal subjects and 16 patients with full course infarction. Characteristic disturbances of motility distribution were found in all cases of scarred or aneurysmic alterations in the frontal and side walls of the left ventricle. The procedure was unable to detect two small infarction scars on the rear wall. The possibility of using radionuclide cinematography to prove coronary insufficiency as well as a comparison with other methods are discussed

  15. Marine biogeochemistry of radionuclides

    International Nuclear Information System (INIS)

    Fowler, S.W.

    1997-01-01

    Radionuclides entering the ocean from runoff, fallout, or deliberate release rapidly become involved in marine biogeochemical cycles. Sources, sinks and transport of radionuclides and analogue elements are discussed with emphasis placed on how these elements interact with marine organisms. Water, food and sediments are the source terms from which marine biota acquire radionuclides. Uptake from water occurs by surface adsorption, absorption across body surfaces, or a combination of both. Radionuclides ingested with food are either assimilated into tissue or excreted. The relative importance of the food and water pathway in uptake varies with the radionuclide and the conditions under which exposure occurs. Evidence suggests that, compared to the water and food pathways, bioavailability of sediment-bound radionuclides is low. Bioaccumulation processes are controlled by many environmental and intrinsic factors including exposure time, physical-chemical form of the radionuclide, salinity, temperature, competitive effects with other elements, organism size, physiology, life cycle and feeding habits. Once accumulated, radionuclides are transported actively by vertical and horizontal movements of organisms and passively by release of biogenic products, e.g., soluble excreta, feces, molts and eggs. Through feeding activities, particles containing radionuclides are ''packaged'' into larger aggregates which are redistributed upon release. Most radionuclides are not irreversibly bound to such particles but are remineralized as they sink and/or decompose. In the pelagic zones, sinking aggregates can further scavenge particle-reactive elements thus removing them from the surface layers and transporting them to depth. Evidence from both radiotracer experiments and in situ sediment trap studies is presented which illustrates the importance of biological scavenging in controlling the distribution of radionuclides in the water column. (author)

  16. Radionuclide concentrations in white sturgeon from the Columbia River

    International Nuclear Information System (INIS)

    Dauble, D.D.; Price, K.R.; Poston, T.M.

    1993-11-01

    The objectives of this study were to (1) review and summarize historical data on radionuclide concentrations in white sturgeon from the Columbia River, (2) determine present-day radionuclide tissue burdens from different locations in the Columbia River, and (3) compare historical data with current data. We first reviewed and summarized the historical literature on radionuclide concentrations in white sturgeon from the Hanford Reach. Field studies were then conducted to evaluate the relationship among sample locations, age/length of white sturgeon, and present radionuclide tissue burdens. Results and comparisons are discussed in the remainder of this report

  17. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Bocock, K.L.

    1981-01-01

    This report summarizes information on the distribution and movement of radionuclides in semi-natural terrestrial ecosystems in north-west England with particular emphasis on inputs to, and outputs from ecosystems; on plant and soil aspects; and on radionuclides in fallout and in discharges by the nuclear industry. (author)

  18. Right and left cardiac function in HIV-infected patients investigated using radionuclide ventriculography and brain natriuretic peptide: a 5-year follow-up study

    DEFF Research Database (Denmark)

    Kristoffersen, U.S.; Lebech, A.M.; Gerstoft, J.

    2008-01-01

    ventricular ejection fraction (RVEF) and left ventricular ejection fraction (LVEF), as well as measurement of brain natriuretic peptide (BNP). Between July 2005 and January 2007, 63 patients (69%) agreed to participate in a follow-up study with a mean follow-up of 4.5 years. RESULTS: All patients had normal......, it seems that the improvement in immunocompetency and viral load has removed the problem of HIV-related cardiomyopathy. Although HAART has been suggested as a possible new cause of cardiomyopathy, we did not find any evidence of this Udgivelsesdato: 2008/3...

  19. Comparison of long-term stability of containment systems for residues and wastes contaminated with naturally occurring radionuclides at an arid site and two humid sites

    International Nuclear Information System (INIS)

    Winters, M.; Merry-Libby, P.; Hinchman, R.

    1985-01-01

    The long-term stability of near-surface containment systems designed for the management of radioactive wastes and residues contaminated with naturally occurring radionuclides are compared at the three different sites. The containment designs are: (1) a diked 8.9-m high mound, including a 3.2-m layered cap at a site (humid) near Lewiston, New York, (2) a 6.8-m-high mound, including a similar 3.2-m cap at a site (humid) near Oak Ridge, Tennessee, and (3) 4.8-m deep trenches with 3.0-m backfilled caps at a site (arid) near Hanford, Washington. Geological, hydrological, and biological factors affecting the long-term (1000-year) integrity of the containment systems at each site are examined, including: erosion, flooding, drought, wildfire, slope and cover failure, plant root penetration, burrowing animals, other soil-forming processes, and land-use changes. For the containment designs evaluated, releases of radon-222 at the arid site are predicted to be several orders of magnitude higher than at the two humid sites - upon initial burial and at 1000 years (after severe erosion). Transfer of wastes containing naturally occurring radionuclides from a humid to an arid environment offers little or no advantage relative to long-term stability of the containment system and has a definite disadvantage in terms of gaseous radioactive releases. 26 references, 3 figures, 4 tables

  20. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    Science.gov (United States)

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by

  1. Evaluation of aspirin therapy on intracardiac thrombi using indium-111-oxine platelet scintigraphy, two-dimentional echocardiography and left ventriculography

    International Nuclear Information System (INIS)

    Shibuya, Masanori; Irino, Tadayoshi; Yoshioka, Toshiharu; Sugimoto, Tsuyoshi; Tsuji, Kazuo; Naka, Masashi; Arai, Hidekazu.

    1984-01-01

    Left ventriculography (LVG), two-dimensional echocardiography (2-DE) and indium-111-oxine platelet scintigraphy were performed in five patients with intracardiac thrombi. Thrombi were visible in 7 sites (5 in the ventricle and 2 in the atrium) by platelet scintigraphy, in 4 sites (3 in the ventricle and 1 in the atrium) by 2-DE, and in 4 sites (4 in the ventricle) by LVG. When aspirin was administered to the patients, platelet scintigraphy had become negative for thrombi in 5 sites and false-negative for them in 2 sites. However, thrombi were detected in 6 sites after the withdrawal of aspirin. On the other hand, thrombi were detected in 4 sites by 2-DE, irrespective of the administration of aspirin. Indium-111-oxine platelet scintigraphy has proved to not only have higher sensitivity for detecting thrombi but also to be capable of observing the coagulation status of platelets on the thrombi. It is therefore considered very helpful in assessing anticoagulation therapy. (Namekawa, K)

  2. Usefulness of acoustic quantification method in left ventricular volume and ejection fraction. Compared with ventriculography and scintigraphy

    International Nuclear Information System (INIS)

    Shibata, Takahiro; Honda, Youichi; Kashiwagi, Hidehiko

    1996-01-01

    Acoustic quantification method (AQ: on-line automated boundary detection system) has proved to have a good correlation with left ventriculography (LVG) and scintigraphy (SG) in patients with normal left ventricular (LV) function. The aim of this study is to determine whether AQ is also useful in patients with abnormal LV function. We examined 54 patients with LV asynergy. End-diastolic volumes with AQ, LVG and SG were 77, 135, 118 ml. A good correlation was found between AQ and LVG and SG (LVG; r=0.81, SG; r=0.68). End-systolic volumes with AQ, LVG and SG were 38, 64 and 57 ml. Left ventricular volumes obtained from AQ had a good correlation with LVG and SG, but were underestimated. LV ejection fraction obtained from AQ had good correlation with those with LVG and SG (LVG; r=0.84. SG; r=0.77). On-line AQ appears to be a useful noninvasive method for evaluation of the left ventricular ejection fraction, but care must be exercised when estimations of left ventricular volumes are made. (author)

  3. Process for encapsulating radionuclides

    International Nuclear Information System (INIS)

    Brownell, L.E.; Isaacson, R.E.

    1976-01-01

    Radionuclides are immobilized in virtually an insoluble form by reacting at a temperature of at least 90 0 C as an aqueous alkaline mixture having a solution pH of at least 10, containing a source of silicon, the radionuclide waste, and a metal cation. The molar ratio of silicon to the metal cation is on the order of unity to produce a gel from which complex metalosilicates crystallize to entrap the radionuclides within the resultant condensed crystal lattice. The product is a silicious stone-like material which is virtually insoluble and nonleachable in alkaline or neutral environment. One embodiment provides for the formation of the complex metalo-silicates, such as synthetic pollucite, by gel formation with subsequent calcination to the solid product; another embodiment utilizes a hydrothermal process, either above ground or deep within basalt caverns, at greater than atmospheric pressures and a temperature between 90 and 500 0 C to form complex metalo-silicates, such as strontium aluminosilicate. Another embodiment provides for the formation of complex metalo-silicates, such as synthetic pollucite, by slurrying an alkaline mixture of bentonite or kaolinite with a source of silicon and the radionuclide waste in salt form. In each of the embodiments a mobile system is achieved whereby the metalo-silicate constituents reorient into a condensed crystal lattice forming a cage structure with the condensed metalo-silicate lattice which completely surrounds the radionuclide and traps the radionuclide therein; thus rendering the radionuclide virtually insoluble

  4. Foodstuffs, radionuclides, monitoring

    International Nuclear Information System (INIS)

    Denisikov, A.I.

    2000-01-01

    Radionuclide contamination of water and food stuffs as a result of the Chernobyl accident and permissible contents of 90 Sr and 137 Cs are considered in brief. A method of radiation monitoring of food stuffs and water for the radionuclides mentioned is suggested. The method permits employment of the simplest and cheapest radiometric equipment for analysis, whole the high degree of radionuclide concentration using fiber sorbents permits using the instrumentation without expensive shields against external radiation. A description of ion-exchange unit for radiation monitoring of liquid samples of food stuffs or water, is provided [ru

  5. Generator for radionuclide

    International Nuclear Information System (INIS)

    Weisner, P.S.; Forrest, T.R.F.

    1985-01-01

    This invention provides a radionuclide generator of the kind in which a parent radionuclide, adsorbed on a column of particulate material, generates a daughter radionuclide which is periodically removed from the column. This invention is particularly concerned with technetium generators using single collection vials. The generator comprises a column, a first reservoir for the eluent, a second reservoir to contain the volume of eluent required for a single elution, and means connecting the first reservoir to the second reservoir and the second reservoir to the column. Such a generator is particularly suitable for operation by vacuum elution

  6. Laboratory studies of radionuclide migration in tuff

    International Nuclear Information System (INIS)

    Rundberg, R.S.; Mitchell, A.J.; Ott, M.A.; Thompson, J.L.; Triay, I.R.

    1989-01-01

    The movement of selected radionuclides has been observed in crushed tuff, intact tuff, and fractured tuff columns. Retardation factors and dispersivities were determined from the elution profiles. Retardation factors have been compared with those predicted on the basis of batch sorption studies. This comparison forms a basis for either validating distribution coefficients or providing evidence of speciation, including colloid formation. Dispersivities measured as a function of velocity provide a means of determining the effect of sorption kinetics or mass transfer on radionuclide migration. Dispersion is also being studied in the context of scaling symmetry to develop a basis for extrapolating from the laboratory scale to the field. 21 refs., 6 figs., 2 tabs

  7. Granulometric analysis of sediments containing transuranic radionuclides

    International Nuclear Information System (INIS)

    Smith, R.M.; Additon, M.K.

    1980-11-01

    A dry sieving technique using a sonic sifter was selected for the granulometric analysis of sediment samples containing radionuclide contamination. A sieve facility was established in the 234-5Z building for this purpose. Fifty-two contaminated sediment samples from the 216-Z-1A crib were sieved in the facility at a rate of two to four samples per day with no major problems. A comparison of particle size and radionuclide concentration indicated that there is no obvious benefit to particle size separation as a means of sediment decontamination, though an economic analysis will have to be conducted before a final decision can be made

  8. Comparison of the Bioavailability of Waste Laden Soils Using ''In Vivo'' ''In Vitro'' Analytical Methodology and Bioaccessibility of Radionuclides for Refinement of Exposure/Dose Estimates; FINAL

    International Nuclear Information System (INIS)

    P. J. Lioy; M. Gallo; P. Georgopoulos; R. Tate; B. Buckley

    1999-01-01

    The bioavailability of soil contaminants can be measured using in vitro or in vivo techniques. Since there was no standard method for intercomparison among laboratories, we compared two techniques for bioavailability estimation: in vitro dissolution and in vivo rat feeding model for a NIST-traceable soil material. Bioaccessibility was measured using a sequential soil extraction in synthetic analogues of human saliva, gastric and intestinal fluids. Bioavailability was measured in Sprague Dawley rats by determining metal levels in the major organs and urine, feces, and blood. Bioaccessibility was found to be a good indicator of relative metal bioavailability. Results are presented from bioaccessible experiments with Cesium in contaminated DOE soils, and total alpha and beta bioaccessibility. The results indicate that the modified methodology for bioaccessibility can be used for specific radionuclide analysis

  9. Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay

    International Nuclear Information System (INIS)

    Takashima, T.; Matsui, O.; Suzuki, M.; Ida, M.

    1982-01-01

    Twenty-nine small (less than 5 cm) hepatocellular carcinomas in 18 patients were examined by radionuclide imaging (RN), ultrasound (US), computed tomography (CT), hepatic angiography, and serum alpha 1-fetoprotein (AFP) assay. Sensitivity was 39% with RN, 50% with US, 56% with CT, and 94% with angiography, including infusion hepatic angiography (IHA). Lesions larger than 3 cm could be detected by all of these methods; those between 2 and 3 cm were generally shown by US and CT but not RN. IHA was essential for diagnosis of lesions less than 2 cm, which were otherwise difficult or impossible to detect except with angiography. As a screening method, AFP was best, followed by US and CT. The authors recommend using AFP and US to minimize expense and radiation exposure. In questionable cases, IHA should be performed

  10. Comparison of the effects of inhaled 239PuO2 and β- emitting radionuclides on the incidence of lung carcinomas in laboratory animals

    International Nuclear Information System (INIS)

    Hahn, F.F.; Griffith, W.C.; Boecker, B.B.; Muggenburg, B.A.; Lundgren, D.L.

    1991-01-01

    The health effects of inhaling radioactive particles when the lung is the primary organ irradiated were studied in rats and Beagle dogs. The animals were exposed to aerosols of 239 PuO 2 or fission-product radionuclides in insoluble forms and observed for their life span. Lung carcinomas were the primary late-occuring effect. The incidence rate for lung carcinomas was modeled using a proportional hazard rate model. Linear functions predominated below 5 Gy to the lung. The life-time risk for lung carcinomas per 10 4 Gy for beta emitters was 60 for rats and 65 for dogs, and for 239 PuO 2 it was 1500 for rats and 2300 for dogs

  11. Comparison of the effects of inhaled 239PuO2 and β-emitting radionuclides of the incidence of lung carcinomas in laboratory animals

    International Nuclear Information System (INIS)

    Hahn, F.F.; Griffith, W.C.; Boecker, B.B.; Muggenburg, B.A.; Lundgren, D.L.

    1992-01-01

    The health effects of inhaling radioactive particles when the lung is the primary organ irradiated were studied in rats and dogs. The animals were exposed to aerosols of 239 PuO 2 or fission-product radionuclides in insoluble forms and observed for their life span. Lung carcinomas were the primary late-occurring effect. The incidence rate for lung carcinomas was modeled using a proportional hazard rate model. Linear functions predominated below 5 Gy to the lung. The life-time risk for lung carcinomas per 10 4 Gy for beta emitters was 60 for rats and 65 for dogs, and for 239 PuO 2 it was 1500 for rats and 2300 for dogs. (author)

  12. I-123-labelled heptadecanoic acid as myocardial imaging agent: comparison with thallium-201 and first-pass nuclear ventriculography

    International Nuclear Information System (INIS)

    Abdullah, A.Z.; Hawkins, L.A.; Britton, K.E.; Elliott, A.T.; Stephens, J.D.

    1981-01-01

    Results of the use of 123 I-iodoheptadecanoic acid (HA) as a myocardial imaging agent in eight patients and six normals are presented. It was shown that 123 I-HA gave comparable results to the widely used radiopharmaceutical 201 Tl. However the advantages of using 123 I-HA are that the 159 KeV energy is better suited to the conventional gamma camera, it gives a lower radiation dose to the patient and has a lower cost per study. 123 I-HA also has an important advantage in its potential for studying regional myocardial metabolic activity; in one patient, a defect due to ischaemia was seen at rest with 123 I-HA but required stress to make it evident with 201 Tl imaging. (U.K.)

  13. Radionuclides in analytical chemistry

    International Nuclear Information System (INIS)

    Tousset, J.

    1984-01-01

    Applications of radionuclides in analytical chemistry are reviewed in this article: tracers, radioactive sources and activation analysis. Examples are given in all these fields and it is concluded that these methods should be used more widely [fr

  14. Radionuclide Basics: Iodine

    Science.gov (United States)

    ... Centers Radiation Protection Contact Us Share Radionuclide Basics: Iodine Iodine (chemical symbol I) is a chemical element. ... in the environment Iodine sources Iodine and health Iodine in the Environment All 37 isotopes of iodine ...

  15. Abscess detection with radionuclides

    International Nuclear Information System (INIS)

    Alavi, J.B.

    1988-01-01

    Radionuclide studies may aid in the diagnosis and localization of intra-abdominal infections. Despite the introduction of new radiographic and ultrasound methods, there are several clinical situations in which radionuclide scans have proved useful. Those include detection of postoperative intra-abdominal abscess, evaluation of liver abscess, differentiation between pancreatic pseudocyst or abscess, evaluation of fever of unknown origin, and evaluation of inflammatory bowel disease. Each clinical situation is discussed separately here

  16. Stochastic analysis of radionuclide migration in saturated-unsaturated soils

    International Nuclear Information System (INIS)

    Kawanishi, Moto

    1988-01-01

    In Japan, LLRW (low level radioactive wastes) generated from nuclear power plants shall be started to store concentrically in the Shimokita site from 1990, and those could be transformed into land disposal if the positive safety is confirmed. Therefore, it is hoped that the safety assessment method shall be successed for the land disposal of LLRW. In this study, a stochastic model to analyze the radionuclide migration in saturated-unsaturated soils was constructed. The principal results are summarized as follows. 1) We presented a generalized idea for the modeling of the radionuclide migration in saturated-unsaturated soils as an advective-dispersion phenomena followed by the decay of radionuclides and those adsorption/desorption in soils. 2) Based on the radionuclide migration model mentioned above, we developed a stochastic analysis model on radionuclide migration in saturated-unsaturated soils. 3) From the comparison between the simulated results and the exact solution on a few simple one-dimensional advective-dispersion problems of radionuclides, the good validity of this model was confirmed. 4) From the comparison between the simulated results by this model and the experimental results of radionuclide migration in a one-dimensional unsaturated soil column with rainfall, the good applicability was shown. 5) As the stochastic model such as this has several advantages that it is easily able to represent the image of physical phenomena and has basically no numerical dissipation, this model should be more applicable to the analysis of the complicated radionuclide migration in saturated-unsaturated soils. (author)

  17. Update of the BIPM.RI(II)-K1.Rn-222 comparison of activity measurements for the radionuclide {sup 222}Rn to include the LNE-LNHB, France

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G. [Bureau International de Poids et Mesures, Pavillon de Breteuil, F-92312 Sevres cedex (France); Cassette, P. [Bureau International de Poids et Mesures, Pavillon de Breteuil, F-92312 Sevres cedex (France); Laboratoire national de metrologie et d' essais -Laboratoire national Henri Becquerel, 91191 Gif-sur-Yvette cedex (France)

    2012-02-15

    In 2007, the Laboratoire national de metrologie et d'essais - Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of {sup 222}Rn to the International Reference System (SIR) for comparison. The value of the activity submitted was about 90 kBq. This key comparison result joins that of Switzerland and Germany in the key comparison database that now contains three results, identifier BIPM.RI(II)-K1.Rn-222. Consequently, the KCRV has been updated and the degrees of equivalence with the KCRV have been evaluated. (authors)

  18. Comparison of the bioaccumulation from seawater and depuration of heavy metals and radionuclides in the spotted dogfish Scyliorhinus canicula (Chondrichthys) and the turbot Psetta maxima (Actinopterygii: Teleostei)

    International Nuclear Information System (INIS)

    Jeffree, Ross A.; Warnau, Michel; Teyssie, Jean-Louis; Markich, Scott J.

    2006-01-01

    The bioaccumulation of selected heavy metals and radionuclides ( 241 Am, 109 Cd, 57 Co, 51 Cr, 134 Cs, 54 Mn and 65 Zn) from seawater was experimentally compared in the Chondrichthyan Scyliorhinus canicula (spotted dogfish) and the Actinopterygian Teleost Psetta maxima (turbot), of comparable size, age and benthic feeding habits. The speciation of these elements in seawater (salinity 38 per mille , pH 8.1, temperature 16.5 deg. C) was also calculated to determine their potential bioavailability. The uptake rates, measured over 14 days, varied greatly among isotopes and between species. Concentration factors (CFs) in P. maxima varied 5-fold between ca. 0.2 for 51 Cr and 2.5 for 65 Zn and 134 Cs, whereas in S. canicula they varied by a much greater factor of 350, with CFs for 51 Cr and 241 Am ranging from ca. 0.4 to 140, respectively. With the exception of 134 Cs, all radiotracers were accumulated at a faster rate in S. canicula than in P. maxima, particularly for 241 Am and 65 Zn where the CFs attained during the uptake phase were, two and one order of magnitude greater in S. canicula, respectively. In contrast, 134 Cs reached a CF of about 2.5 in P. maxima, which was 5-fold greater than in S. canicula. Patterns of loss from the experimental depuration phase over 29 days showed greater similarities between species, compared to the uptake phase that highlighted the greater differences between elements. The distributions of these seven radioisotopes among six body components indicated that between the two species the skin of the dogfish displayed a greater bioaccumulation potential, particularly for 241 Am, 57 Co and 65 Zn. However 65 Zn was also distinctive from 241 Am and 57 Co in its pattern of bioaccumulation in dogfish, with its other body components attaining concentrations of 65 Zn that were comparable to the levels found in its skin. The heightened uptake of 134 Cs in turbot was characterised by a more even percentage distribution among its tissues compared to

  19. Quantitative Computed Tomography Ventriculography for Assessment and Monitoring of Hydrocephalus: A Pilot Study and Description of Method in Subarachnoid Hemorrhage.

    Science.gov (United States)

    Multani, Jasjit Singh; Oermann, Eric Karl; Titano, Joseph; Mascitelli, Justin; Nicol, Kelly; Feng, Rui; Skovrlj, Branko; Pain, Margaret; Mocco, J D; Bederson, Joshua B; Costa, Anthony; Shrivastava, Raj

    2017-08-01

    There is no facile quantitative method for monitoring hydrocephalus (HCP). We propose quantitative computed tomography (CT) ventriculography (qCTV) as a novel computer vision tool for empirically assessing HCP in patients with subarachnoid hemorrhage (SAH). Twenty patients with SAH who were evaluated for ventriculoperitoneal shunt (VPS) placement were selected for inclusion. Ten patients with normal head computed tomography (CTH) findings were analyzed as negative controls. CTH scans were segmented both manually and automatically (by qCTV) to generate measures of ventricular volume. The median manually calculated ventricular volume was 36.1 cm 3 (interquartile range [IQR], 30-115 cm 3 ), which was similar to the median qCTV measured volume of 37.5 cm 3 (IQR, 32-118 cm 3 ) (P = 0.796). Patients undergoing VPS placement demonstrated an increase in median ventricular volume on qCTV from 21 cm 3 to 40 cm 3 on day T-2 and to 51 cm 3 by day 0, a change of 144%. This is in contrast to patients who did not require shunting, in whom median ventricular volume decreased from 16 cm 3 to 14 cm 3 on day T-2 and to 13 cm 3 by day 0, with an average overall volume decrease 19% (P = 0.001). The average change in ventricular volume predicted which patients would require VPS placement, successfully identifying 7 of 10 patients (P = 0.004). Using an optimized cutoff of a change in ventricular volume of 2.5 cm 3 identified all patients who went on to require VPS placement (10 of 10; P = 0.011). qCTV is a reliable means of quantifying ventricular volume and hydrocephalus. This technique offers a new tool for monitoring neurosurgical patients for hydrocephalus, and may be beneficial for use in future research studies, as well as in the routine care of patients with hydrocephalus. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Summary of intensive monitoring for radionuclides in fishery products after Fukushima accident and comparison to the results of long term monitoring program in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Ken; Morita, Takami; Shigenobu, Yuya; Takagi, Kaori; Miki, Shizuho; Kaeriyama, Hideki; Ambe, Daisuke; Ono, Tsuneo [National Research Institute of Fisheries Science, Fisheries Research Agency, 2-12-4, Fukuura, Kanazawa, Yokohama, Kanagawa 236-8648 (Japan)

    2014-07-01

    Monitoring of artificial radionuclides in fishery products started in late 1950's and has over half a century history in Japan. Fisheries Agency (FA), Fisheries Research Agency (FRA) and prefectural organizations have been conducting the monitoring. The intensive monitoring of radioactive material in fishery products started in the late of March 2011 immediately after the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident for the coastal area faced to the Pacific Ocean in the eastern area of Japan and for the offshore area. The purpose of this monitoring is to avoid the distribution of fishery products containing radioactive cesium in concentration over the Japanese standard limit (Cs-134+Cs-137: 100 Bq/kg). Japanese monitoring data are opened to public on the FA's and FRA's web page. In this study, we resume the results of intensive monitoring started in 2011 and show the temporal change of concentration of radioactive cesium in fishery product. In Fukushima Prefecture, the ratio of samples exceeding the Japanese standard limit shows a steadily decreasing trend from 53% at Mar.- Jun. 2011 to below 3% at Jul. - Sep. 2013. In other prefectures, the ratio was 6.5% at Mar.- Jun. 2011 and fell gradually, and it has been below to 1% at Jul. - Sep. 2013. In presentation, we show the results of monitoring conducted in the coastal area and deeper water around Japan from long gamma ray measurements with ashed samples by high purified germanium gamma spectrometry. (authors)

  1. Sensitivity of computer assisted radionuclide angiography in transient ischemic attack and prolonged reversible ischemic neurological deficit. Comparison with findings in radiographic angiography and transmission computerized axial tomography

    International Nuclear Information System (INIS)

    Buell, U.; Scheid, K.F.; Lanksch, W.; Kleinhans, E.; Ulbert, V.; Reger, U.; Rath, M.; Moser, E.A.

    1981-01-01

    Computer assisted radionuclide angiography (CARNA) with 99mTc-DTPA was employed to study 143 patients with transient ischemic attacks (TIA) and 79 patients with prolonged reversible ischemic neurologic deficit (PRIND). The results of CARNA were compared with findings from radiographic angiography (RGA) in 173 patients and with findings in transmission computerized axial tomography (T-CAT) in 154 patients. In patients with TIA, CARNA showed a hemispherical perfusion deficit in 74.8%, and with PRIND 87.3%. This deficit, determined as the relative difference between the involved and the non-involved hemisphere, was significantly (p less than 0.0025) greater in PRIND (minus 23%) than in TIA (minus 17%). Sensitivity of CARNA was independent of the interval from ictus to examination for more than 4 months. RGA in TIA revealed true positives in 82.0%, in PRIND it was 89.5%. T-CAT was positive in TIA in only 16.8% but in PRIND it was 64.4%. Combined sensitivities in TIA (92.4%) and in PRIND (94.0%) were highest with the combination of CARNA and RGA. However, in PRIND the combination of non-invasive methods (CARNA and T-CAT) revealed 93.2% positive findings. Combinations of these evaluation methods may be used to detect cerebrovascular disease in patients with such dysfunction

  2. Myocardial function and perfusion in the CREST syndrome variant of progressive systemic sclerosis. Exercise radionuclide evaluation and comparison with diffuse scleroderma

    International Nuclear Information System (INIS)

    Follansbee, W.P.; Curtiss, E.I.; Medsger, T.A. Jr.; Owens, G.R.; Steen, V.D.; Rodnan, G.P.

    1984-01-01

    Myocardial function and perfusion were evaluated in 22 patients with progressive systemic sclerosis with the CREST syndrome using exercise and radionuclide techniques, pulmonary function testing, and chest roentgenography. The results were compared with a similar study of 26 patients with progressive systemic sclerosis with diffuse scleroderma. The prevalence of thallium perfusion abnormalities was similar in the groups with CREST syndrome and diffuse scleroderma, (64 percent versus 77 percent), but the defects were significantly smaller in the CREST syndrome (p less than 0.01). Reperfusion thallium defects in the absence of extramural coronary artery disease were seen in 38 percent of patients with diffuse scleroderma. This finding was not seen in any of the patients with the CREST syndrome. In diffuse scleroderma, abnormalities of both right and left ventricular function were related to larger thallium perfusion defects. In the CREST syndrome, abnormalities of left ventricular function were minor, were seen only during exercise, and were unrelated to thallium perfusion defects. Abnormal resting right ventricular function was seen in 36 percent of the patients with the CREST syndrome and was associated with an isolated decrease in diffusing capacity of carbon monoxide. It is concluded that the cardiac manifestations of the CREST syndrome are distinct from those found in diffuse scleroderma. Unlike diffuse scleroderma, abnormalities of left ventricular function in the CREST syndrome are minor and are unrelated to abnormalities of coronary perfusion. Right ventricular dysfunction in the CREST syndrome appears to be primarily related to pulmonary vascular disease

  3. Correction for tissue attenuation in radionuclide gastric emptying studies: a comparison of a lateral image method and a geometric mean method

    Energy Technology Data Exchange (ETDEWEB)

    Collins, P.J.; Chatterton, B.E. (Royal Adelaide Hospital (Australia)); Horowitz, M.; Shearman, D.J.C. (Adelaide Univ. (Australia). Dept. of Medicine)

    1984-08-01

    Variation in depth of radionuclide within the stomach may result in significant errors in the measurement of gastric emptying if no attempt is made to correct for gamma-ray attenuation by the patient's tissues. A method of attenuation correction, which uses a single posteriorly located scintillation camera and correction factors derived from a lateral image of the stomach, was compared with a two-camera geometric mean method, in phantom studies and in five volunteer subjects. A meal of 100 g of ground beef containing /sup 99/Tcsup(m)-chicken liver, and 150 ml of water was used in the in vivo studies. In all subjects the geometric mean data showed that solid food emptied in two phases: an initial lag period, followed by a linear emptying phase. Using the geometric mean data as a standard, the anterior camera overestimated the 50% emptying time (T/sub 50/) by an average of 15% (range 5-18) and the posterior camera underestimated this parameter by 15% (4-22). The posterior data, corrected for attenuation using the lateral image method, underestimated the T/sub 50/ by 2% (-7 to +7). The difference in the distances of the proximal and distal stomach from the posterior detector was large in all subjects (mean 5.7 cm, range 3.9-7.4).

  4. Estimation of the compliance of the human capacitance vessels using radionuclide plethysmography. Comparison of the compliance with the NYHA functional classification

    Energy Technology Data Exchange (ETDEWEB)

    Takatsu, Hisato; Gotoh, Kohshi; Suzuki, Takahiko and others

    1988-01-01

    Radionuclide (RN) plethysmography with Tc-99m RBC was performed in 32 patients with heart disease with the purpose of obtaining compliance of human capacitance vessels. When equilibrium was achieved, RN counts of the region of interest and venous pressure in the forearm were sequentially recorded when the vein of the upper arm was occluded with a cuff inflator. Based on the RN count-venous pressure curve, the specific compliance of the forearm vein and compliance of systemic venous system (SVS) were estimated. In the group of the NYHA functional classification I, which is recognized as hemodynamically ''normal'', the compliance of SVS was 129.8 +- 25.9 ml center dot mmHg/sup -1/ (mean +- SD; n = 9). In comparing the NYHA functional classification and the compliance of SVS, the compliance of SVS was significantly decreased for severer heart failure. Tongue administration of nitroglycerin (0.6 mg) significantly increased the compliance of SVS (p < 0.01). (Namekawa, K.).

  5. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  6. Radionuclide fixation mechanisms in rocks

    International Nuclear Information System (INIS)

    Nakashima, S.

    1991-01-01

    In the safety evaluation of the radioactive waste disposal in geological environment, the mass balance equation for radionuclide migration is given. The sorption of radionuclides by geological formations is conventionally represented by the retardation of the radionuclides as compared with water movement. In order to quantify the sorption of radionuclides by rocks and sediments, the distribution ratio is used. In order to study quantitatively the long term behavior of waste radionuclides in geological environment, besides the distribution ratio concept in short term, slower radionuclide retention reaction involving mineral transformation should be considered. The development of microspectroscopic method for long term reaction path modeling, the behavior of iron during granite and water interaction, the reduction precipitation of radionuclides, radionuclide migration pathways, and the representative scheme of radionuclide migration and fixation in rocks are discussed. (K.I.)

  7. Sediment and radionuclide transport in rivers: radionuclide transport modeling for Cattaraugus and Buttermilk Creeks, New York

    International Nuclear Information System (INIS)

    Onishi, Y.; Yabusaki, S.B.; Kincaid, C.T.; Skaggs, R.L.; Walters, W.H.

    1982-12-01

    SERATRA, a transient, two-dimensional (laterally-averaged) computer model of sediment-contaminant transport in rivers, satisfactorily resolved the distribution of sediment and radionuclide concentrations in the Cattaraugus Creek stream system in New York. By modeling the physical processes of advection, diffusion, erosion, deposition, and bed armoring, SERATRA routed three sediment size fractions, including cohesive soils, to simulate three dynamic flow events. In conjunction with the sediment transport, SERATRA computed radionuclide levels in dissolved, suspended sediment, and bed sediment forms for four radionuclides ( 137 Cs, 90 Sr, 239 240 Pu, and 3 H). By accounting for time-dependent sediment-radionuclide interaction in the water column and bed, SERATA is a physically explicit model of radionuclide fate and migration. Sediment and radionuclide concentrations calculated by SERATA in the Cattaraugus Creek stream system are in reasonable agreement with measured values. SERATRA is in the field performance phase of an extensive testing program designed to establish the utility of the model as a site assessment tool. The model handles not only radionuclides but other contaminants such as pesticides, heavy metals and other toxic chemicals. Now that the model has been applied to four field sites, including the latest study of the Cattaraugus Creek stream system, it is recommended that a final model be validated through comparison of predicted results with field data from a carefully controlled tracer test at a field site. It is also recommended that a detailed laboratory flume be tested to study cohesive sediment transport, deposition, and erosion characteristics. The lack of current understanding of these characteristics is one of the weakest areas hindering the accurate assessment of the migration of radionuclides sorbed by fine sediments of silt and clay

  8. Comparison of [68Ga]Ga-PSMA-11 PET/CT with [18F]NaF PET/CT in the evaluation of bone metastases in metastatic prostate cancer patients prior to radionuclide therapy.

    Science.gov (United States)

    Uprimny, Christian; Svirydenka, Anna; Fritz, Josef; Kroiss, Alexander Stephan; Nilica, Bernhard; Decristoforo, Clemens; Haubner, Roland; von Guggenberg, Elisabeth; Buxbaum, Sabine; Horninger, Wolfgang; Virgolini, Irene Johanna

    2018-05-16

    The purpose of this study was to investigate the diagnostic performance of 68 Ga-PSMA-11 PET/CT in the evaluation of bone metastases in metastatic prostate cancer (PC) patients scheduled for radionuclide therapy in comparison to [ 18 F]sodium fluoride ( 18 F-NaF) PET/CT. Sixteen metastatic PC patients with known skeletal metastases, who underwent both 68 Ga-PSMA-11 PET/CT and 18 F-NaF PET/CT for assessment of metastatic burden prior to radionuclide therapy, were analysed retrospectively. The performance of both tracers was calculated on a lesion-based comparison. Intensity of tracer accumulation of pathologic bone lesions on 18 F-NaF PET and 68 Ga-PSMA-11 PET was measured with maximum standardized uptake values (SUV max ) and compared to background activity of normal bone. In addition, SUV max values of PET-positive bone lesions were analysed with respect to morphologic characteristics on CT. Bone metastases were either confirmed by CT or follow-up PET scan. In contrast to 468 PET-positive lesions suggestive of bone metastases on 18 F-NaF PET, only 351 of the lesions were also judged positive on 68 Ga-PSMA-11 PET (75.0%). Intensity of tracer accumulation of pathologic skeletal lesions was significantly higher on 18 F-NaF PET compared to 68 Ga-PSMA-11 PET, showing a median SUV max of 27.0 and 6.0, respectively (p PET, with a median SUV max of 1.0 in comparison to 2.7 on 18 F-NaF PET; however, tumour to background ratio was significantly higher on 18 F-NaF PET (9.8 versus 5.9 on 68 Ga-PSMA-11 PET; p = 0.042). Based on morphologic lesion characterisation on CT, 18 F-NaF PET revealed median SUV max values of 23.6 for osteosclerotic, 35.0 for osteolytic, and 19.0 for lesions not visible on CT, whereas on 68 Ga-PSMA-11 PET median SUV max values of 5.0 in osteosclerotic, 29.5 in osteolytic, and 7.5 in lesions not seen on CT were measured. Intensity of tracer accumulation between 18 F-NaF PET and 68 Ga-PSMA-11 PET was significantly higher in osteosclerotic (p

  9. Radioactivity: radionuclides in foods

    International Nuclear Information System (INIS)

    Simpson, R.E.; Baratta, E.J.; Jelinek, C.F.

    1977-01-01

    The results are summarized of the analysis for strontium-90, cesium-137, iodine-131, ruthenium-106, and potassium-40, a naturally occurring radionuclide, in samples of total diet and selected import commodities in the foods compliance program of the Food and Drug Administration. On the basis of the radionuclide intake guidelines established by the Federal Radiation Council (FRC), the low content of radionuclides found in the total diet samples for fiscal years 1973 and 1974 demonstrates the need for surveillance only at the present level. The low levels of radionuclides found in a limited number of edible imported commodities indicate that their contribution to the total diet would not increase the levels of these radionuclides above those recommended for only periodic surveillance by the FRC. The potassium levels, determined from potassium-40 activity, found in meats and fish agree with the value for normal muscle tissue for the reference man reported by the International Commission on Radiation Protection. Of the other commodities, nuts contained the highest levels, while sugar, beverages, and processed foods contained the lowest levels of potassium. Although cesium and potassium are chemical analogs with similar metabolic properties, because of their variable content in some leafy samples as a result of surface contamination, a correlation between cesium-137 levels and the cesium-137-to-potassium ratio was inconclusive

  10. Activity measurements of the radionuclide {sup 124}Sb by the LNE-LNHB, France for the ongoing comparison BIPM.RI(II)-K1.Sb-124

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, F-92312 Sevres Cedex, (France); Moune, M.; Bobin, C. [Laboratoire national de metrologie et d' essais-Laboratoire national Henri Becquerel, 91191 Gif-sur-Yvette cedex, (France)

    2011-07-01

    In 2007, the Laboratoire national de metrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB), France submitted a sample of known activity of {sup 124}Sb to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). The activity was about 5.3 MBq. The key comparison reference value (KCRV) has been recalculated to include this new value and the degrees of equivalence between each equivalent activity for the three participants measured in the SIR and the KCRV are presented in a table and graphically. (authors)

  11. A comparison of radionuclide thyroid angiography, 99mTc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Demirel, Koray; Kapucu, Oezlem; Yuecel, Cem; Oezdemir, Hakan; Ayvaz, Goeksun; Taneri, Ferit

    2003-01-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. 99m Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed 99m Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for 99m Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, 99m Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign thyroid nodules. (orig.)

  12. Osmium-191 → iridium-191m radionuclide generator: development and clinical application. Progress report, March 1, 1981-February 28, 1982

    International Nuclear Information System (INIS)

    Treves, S.; Cheng, C.

    1981-01-01

    A prototype osmium-191 (T 1/2 = 16 days) → iridium-191m (T 1/2 = 4.9 seconds) generator designed for first pass radionuclide angiography was developed in our laboratory (Os-191 → Ir-191m). Our generator had 14 to 20% Ir-191m yield and a 1 to 3 x 10 -3 % Os-191 breakthrough. Iridium-191m decays with emission of a 65 and a 129 keV photon in 50% and 25% abundance respectively. This radionuclide is advantageous for angiography since it provides higher photon flux and results in much lower radiation dose to the patient than Tc-99m. One objective of this research is to improve the Os-191 → Ir-191m generator for first pass radionuclide angiography at an increase in the Ir-191m yield and a decrease in the Os-191 breakthrough. In addition, we would like to develop an Os-191 → Ir-191m generator for continuous infusion which will be used for ECG gated blood pool ventriculography, venography, and arteriography. Another approach will be to develop a carrier free Os-191 → Ir-191m generator in combination with organic or inorganic exchangers. Iridium-191m from our current generator has been employed successfully in two patient studies for the quantitation left-to-right shunting and the measurement of right and left ventricular ejection fractions. These types of studies will be expanded and further evaluated

  13. Radionuclides in house dust

    CERN Document Server

    Fry, F A; Green, N; Hammond, D J

    1985-01-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, alt...

  14. Radionuclides in foods

    International Nuclear Information System (INIS)

    1994-01-01

    This report contains data on the levels of radionuclides in the UK foodchain. Most data derive from monitoring programmes that exist around nuclear sites, and in some cases date back to the 1960s. Some comparative data from site operator and government-run programmes are included. Data from monitoring undertaken after the Chernobyl accident are summarised. General monitoring of the foodchain for both artificial and natural radionuclides, and the results of relevant government-sponsored research are also described. The report includes basic information on radioactivity in the environment, radiation protection standards and describes what measures are taken to routinely monitor the foodchain and assess public risk. (Author)

  15. Targeted Radionuclide Therapy

    Directory of Open Access Journals (Sweden)

    David Cheng

    2011-10-01

    Full Text Available Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose.

  16. Targeted Radionuclide Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ersahin, Devrim, E-mail: devrimersahin@yahoo.com; Doddamane, Indukala; Cheng, David [Department of Diagnostic Radiology, School of Medicine, Yale University, 333 Cedar St., New Haven, CT 06520 (United States)

    2011-10-11

    Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose.

  17. Radionuclide deposition control

    International Nuclear Information System (INIS)

    1980-01-01

    A method is described for controlling the deposition, on to the surfaces of reactor components, of the radionuclides manganese-54, cobalt-58 and cobalt-60 from a liquid stream containing the radionuclides. The method consists of disposing a getter material (nickel) in the liquid stream, and a non-getter material (tantalum, tungsten or molybdenum) as a coating on the surfaces where deposition is not desired. The process is described with special reference to its use in the coolant circuit in sodium cooled fast breeder reactors. (U.K.)

  18. Radionuclide examination in rheumatology

    International Nuclear Information System (INIS)

    Streda, A.; Kolar, J.; Valesova, M.

    1984-01-01

    On the basis of twenty years of experience with the use of radionuclides in bone and articular rheumatic diseases indications for such examinations are summed up. The main advantage of the use of radionuclide methods is that they bring forward early diagnosis of tissue reconstruction which can thus be detected at the stage of microstructural changes. They also provide earlier and more reliable detection of the degree of the pathological process than is provided by X-ray examination. In some cases scintiscan may also be found useful as a method for following up the results of treatment of rheumatic diseases. (author)

  19. Targeted Radionuclide Therapy

    International Nuclear Information System (INIS)

    Ersahin, Devrim; Doddamane, Indukala; Cheng, David

    2011-01-01

    Targeted radiotherapy is an evolving and promising modality of cancer treatment. The killing of cancer cells is achieved with the use of biological vectors and appropriate radionuclides. Among the many advantages of this approach are its selectiveness in delivering the radiation to the target, relatively less severe and infrequent side effects, and the possibility of assessing the uptake by the tumor prior to the therapy. Several different radiopharmaceuticals are currently being used by various administration routes and targeting mechanisms. This article aims to briefly review the current status of targeted radiotherapy as well as to outline the advantages and disadvantages of radionuclides used for this purpose

  20. Consultative committee on ionizing radiation: Impact on radionuclide metrology

    International Nuclear Information System (INIS)

    Karam, L.R.; Ratel, G.

    2016-01-01

    In response to the CIPM MRA, and to improve radioactivity measurements in the face of advancing technologies, the CIPM's consultative committee on ionizing radiation developed a strategic approach to the realization and validation of measurement traceability for radionuclide metrology. As a consequence, measurement institutions throughout the world have devoted no small effort to establish radionuclide metrology capabilities, supported by active quality management systems and validated through prioritized participation in international comparisons, providing a varied stakeholder community with measurement confidence. - Highlights: • Influence of CIPM MRA on radionuclide metrology at laboratories around the world. • CCRI strategy: to be the “undisputed hub for ionizing radiation global metrology.” • CCRI Strategic Plan stresses importance of measurement confidence for stakeholder. • NMIs increasing role in radionuclide metrology by designating institutions (DIs). • NMIs and DIs establish quality systems; validate capabilities through comparisons.

  1. Activity measurements of the radionuclide 109Cd for the PTB, Germany and the NIST, USA in the ongoing comparison BIPM.RI(II)-K1.Cd-109

    International Nuclear Information System (INIS)

    Ratel, G.; Michotte, C.; Janssen, H.; Kossert, K.; Lucas, L.; Karam, L.

    2005-01-01

    In 2004, the Physikalisch-Technische Bundesanstalt (PTB, Germany) and the National Institute of Standards and Technology (NIST, USA) each submitted one sample of known activity of 109 Cd to the International Reference System (SIR). The PTB result replaces their previous measurement of 1994 and the NIST result updates their 1986 CCRI(II) comparison result. The values of the activity submitted were about 15 MBq and 42 MBq. The new key comparison results have replaced the earlier values in the matrix of degrees of equivalence that now contains six results, identifier BIPM.RI(II)-K1.Cd-109, to which the remaining eleven results from the CCRI(II)-K2.Cd-109 held in 1986 are still linked. (authors)

  2. A comparison of radionuclide thyroid angiography, {sup 99m}Tc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Kapucu, Oezlem [Department of Nuclear Medicine, Gazi University School of Medicine, Ankara (Turkey); Yuecel, Cem; Oezdemir, Hakan [Department of Radiology, Gazi University School of Medicine, Ankara (Turkey); Ayvaz, Goeksun [Department of Endocrinology and Metabolic Diseases, Gazi University School of Medicine, Ankara (Turkey); Taneri, Ferit [Department of Surgery, Gazi University School of Medicine, Ankara (Turkey)

    2003-05-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. {sup 99m}Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed {sup 99m}Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for {sup 99m}Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, {sup 99m}Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign

  3. Removal of some radionuclides from water by bioaccumulation

    International Nuclear Information System (INIS)

    Miskovic, D.; Conkic, L.; Dalmacija, B.; Gantar, M.

    1992-01-01

    First objective of this study was to investigate the application of biologically activated carbon (BAC) as well as its comparison to adsorption, with the aim of removing some radionuclides from water. The isotopes Cs 134 and Cs 137 were bioaccumulated by BAC up to 50%, while the I 131 isotope was only physicochemically adsorbed (about 40%). Also, the process of radionuclides (Cs 137 , Ce 139 , Co 57 , Co 60 ) fixation on blue-green algae (Nostoc sp.) was investigated. The kinetics of the removal of these radionuclides from water was recorded. It was found that after a contact period of about half an hour 40-70% of the activity was removed. (Author)

  4. Radionuclide migration in the unsaturated zone with a variable hydrology

    International Nuclear Information System (INIS)

    Elert, M.; Collin, M.; Andersson, Birgitta; Lindgren, M.

    1990-01-01

    Radionuclide transport from contaminated ground water to the root zone of a soil has been modelled considering a variable hydrology. Hydrological calculations have been coupled with radionuclide transport calculations in order to study the influence of variations in flow rate and saturation, dispersion, and sorption. For non-sorbing radionuclides important seasonal variations in the root zone concentration were found. The dispersivity parameter proved to be very important for both sorbing and non-sorbing nuclides. In addition, some comparison calculations were made with a simple steady-state compartment model. (au)

  5. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  6. Final report on COOMET.RI(II)-S2.Cs-137 (319/RU/04): Comparison measurements of radionuclide volume sources (Cs-137)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Cs-137 specific activity in artificial volume material of water density were performed in nine laboratories with HPGe spectrometry technique. Analysis of the gamma radiation absorption in measured material and in the most important for environmental monitoring substances (food, water, biological materials, soils) confirmed the Compton scattering as the main mechanism of interaction. The list of CMCs supported by the comparison is suggested. (authors)

  7. A quality control exercise of radionuclide calibrators among Belgian hospitals

    International Nuclear Information System (INIS)

    Reher, D.F.G.; Merlo, P.

    1990-01-01

    On the initiative of the Belgian Association of Hospital Physicists, eleven Belgian hospitals participated in a quality control of radionuclide calibrators conducted in collaboration with the Central Bureau for Nuclear Measurements of the Commission of the European Communities. For practical reasons the nuclide 57 Co was chosen. The results from 20 different radionuclide calibrators show a fair agreement with a similar comparison carried out in 1980 in the UK. (orig.)

  8. Taking radionuclides to heart

    International Nuclear Information System (INIS)

    Kleynhans, P.H.T.; Lotter, M.G.; Van Aswegen, A.; Minnaar, P.C.; Iturralde, M.; Herbst, C.P.; Marx, D.

    1980-01-01

    Ischaemic heart disease is a main cause of death in South Africa. Non-invasive ECG gated radionuclide bloodpool imaging plays an increasingly useful role in the evalution of the function of the heart as a pump, and the extent of heart muscle perfusion defects is further pinpointed by invasive krypton-81m studies to improve patient management

  9. Radionuclides deposition over Antarctica

    International Nuclear Information System (INIS)

    Pourchet, M.; Magand, O.; Frezzotti, M.; Ekaykin, A.; Winther, J.-G.

    2003-01-01

    A detailed and comprehensive map of the distribution patterns for both natural and artificial radionuclides over Antarctica has been established. This work integrates the results of several decades of international programs focusing on the analysis of natural and artificial radionuclides in snow and ice cores from this polar region. The mean value (37±20 Bq m -2 ) of 241 Pu total deposition over 28 stations is determined from the gamma emissions of its daughter 241 Am, presenting a long half-life (432.7 yrs). Detailed profiles and distributions of 241 Pu in ice cores make it possible to clearly distinguish between the atmospheric thermonuclear tests of the fifties and sixties. Strong relationships are also found between radionuclide data ( 137 Cs with respect to 241 Pu and 210 Pb with respect to 137 Cs), make it possible to estimate the total deposition or natural fluxes of these radionuclides. Total deposition of 137 Cs over Antarctica is estimated at 760 TBq, based on results from the 90-180 deg. East sector. Given the irregular distribution of sampling sites, more ice cores and snow samples must be analyzed in other sectors of Antarctica to check the validity of this figure

  10. Soil burden by radionuclides

    International Nuclear Information System (INIS)

    Blum, W.E.H.; Wenzel, W.W.

    1989-01-01

    Natural radioactivity - half-lifes and radiation type of man-made nuclides, radionuclide behaviour in soils, effects on soil condition and soil functions are described. The only mode of decontamination is by decay and thus primarily dependent on the half-life of nuclides

  11. Radionuclides in house dust

    Energy Technology Data Exchange (ETDEWEB)

    Fry, F A; Green, N; Dodd, N J; Hammond, D J

    1985-04-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate authorising Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, although radionuclides originating rom the BNFL site can be detected in house dust, this source of contamination is a negligible route of exposure for members of the public in West Cumbria. This report presents the results of the Board's study of house dust in twenty homes in Cumbria during the spring and summer of 1984. A more intensive investigation is being carried out by Imperial College. (author)

  12. Radionuclide body function imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1983-01-01

    A transverse radionuclide scan field imaging apparatus is claimed. It comprises: a plurality of highly focused closely laterally adjacent collimators arranged inwardly focused in an array which surrounds a scan field, each collimator being moveable relative to its adjacent collimator; means for rotating the array about the scan field and means for imparting travel to the collimators

  13. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    Energy Technology Data Exchange (ETDEWEB)

    Korostin, S. [All Russian Research Institute for Physical-Technical and Radio-Technical Measurements (VNIIFTRI), Mendeleevo (Russian Federation); Hernandez, T.; Oropesa, P. [Center of Isotopes - Radionuclide Metrology Department (CENTIS-DMR), Habana (Cuba); Arnold, D. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany); Evseev, V. [National Scientific Centre ' Institute of Metrology' (NSC IM), Kharkov (Ukraine); Ivanukovich, A.; Milevskiy, V. [Belarusian State Institute of Metrology (BelGIM), Minsk (Belarus); Svec, A. [Slovak Institute of Metrology (SMU), Bratislava (Slovakia); Lapenas, A. [Latvian National Metrology Centre Ltd, Radiation Metrology and Testing Centre (RMTC), Salaspils (Latvia); Andonova, V. [Bulgarian Institute of Metrology - National Centre of Metrology (BIM-NCM), Sofia (Bulgaria); Steiner, V. [Ministry of the Environment - Radiation and Noise Division (ISR-MoE), Jerusalem (Israel)

    2010-04-15

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  14. Final report on COOMET.RI(II)-S2.Eu-152 (319/RU/04): Comparison measurements of radionuclide volume sources (Eu-152)

    International Nuclear Information System (INIS)

    Korostin, S.; Hernandez, T.; Oropesa, P.; Arnold, D.; Evseev, V.; Ivanukovich, A.; Milevskiy, V.; Svec, A.; Lapenas, A.; Andonova, V.; Steiner, V.

    2010-01-01

    Measurements of the Eu-152 specific activity in artificial volume sample of water density were performed in nine laboratories with the HPGe spectrometry technique. Analysis of the gamma radiation absorption in the sample material confirmed the Compton scattering as the main mechanism of interaction of photons with energy between 300 - 600 keV and 779 - 1408 keV in the most important for environmental monitoring substances (food, water, biological materials, soils). A list of CMCs supported by the comparison is suggested. (authors)

  15. Scope and role of radioisotope examinations of ischemic heart diseases

    International Nuclear Information System (INIS)

    Orosz, Istvan; Loerinczy, Endre; Zetenyi, Agnes; Pap, Sandor; Deli, Laszlo

    1990-01-01

    Detection of myocardial ischemia due to the effects of coronary vessels may be achieved by means of thallium 201 myocardial scintiscanning and of ventriculography under load. Results of 214 myocardial scintiscanner tests and of 14 radionuclide ventriculographies are presented. In comparison with results obtained by coronarography, sensitivity and specificity of these methods approach the values accepted in literature. (author) 40 refs.; 3 figs.; 7 tabs

  16. Radionuclides in food

    International Nuclear Information System (INIS)

    Fernandez Gomez, Isis Maria

    2008-01-01

    The sources of the presence of radionuclides in food are presented: natural radiation and artificial radiation. The transfer of radionuclides through food chains, intakes of radionuclides to the body with its partners effective doses and typical consumption of basic foods of a rural adult population are exposed as main topics. Also the radiation doses from natural sources and exposure to man by ingestion of contaminated food with radionuclides of artificial origin are shown. The contribution of the food ingestion to the man exposure depends on: characteristics of radionuclide, natural conditions, farming practices and eating habits of the population. The principal international organizations in charge of setting guide levels for radionuclides in food are mentioned: standards, rules and the monitoring. It establishes that a guide is necessary for the food monitoring; the alone CODEX ALIMENTARIUS is applicable to emergency situations and the generic action levels proposed by the CODEX not satisfy all needs (no guiding international levels for planned or existing situations such as NORM). There are handled mainly socio-economic and political aspects. Among the actions to be taken are: to assure a public comprehensive information over the risk evaluation in food; to reinforce the collaboration among the different international organizations (WHO, IAEA, ICRP, EC) in relation with the food of set; to give follow-up to the control of the drinkable water and NORM's presence in the food. In addition, it is possible to create the necessary mechanisms to reduce the number of irrelevant measures and bureaucratic useless steps (certificates); to promote the exchange between the different institutions involved in the topic of the food, with relation to the acquired experiences and learned lessons. Likewise, it might examine the possibility of a multidisciplinary approximation (radioactive and not radioactive pollutants); to elaborate a technical guide to assure the

  17. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    J. Prouty

    2006-01-01

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment (TSPA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers advective transport and diffusive transport

  18. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J. Prouty

    2006-07-14

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment (TSPA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers advective transport and diffusive transport

  19. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    Schreiner, R.

    2001-01-01

    The purpose of this work is to develop the Engineered Barrier System (EBS) radionuclide transport abstraction model, as directed by a written development plan (CRWMS M and O 1999a). This abstraction is the conceptual model that will be used to determine the rate of release of radionuclides from the EBS to the unsaturated zone (UZ) in the total system performance assessment-license application (TSPA-LA). In particular, this model will be used to quantify the time-dependent radionuclide releases from a failed waste package (WP) and their subsequent transport through the EBS to the emplacement drift wall/UZ interface. The development of this conceptual model will allow Performance Assessment Operations (PAO) and its Engineered Barrier Performance Department to provide a more detailed and complete EBS flow and transport abstraction. The results from this conceptual model will allow PA0 to address portions of the key technical issues (KTIs) presented in three NRC Issue Resolution Status Reports (IRSRs): (1) the Evolution of the Near-Field Environment (ENFE), Revision 2 (NRC 1999a), (2) the Container Life and Source Term (CLST), Revision 2 (NRC 1999b), and (3) the Thermal Effects on Flow (TEF), Revision 1 (NRC 1998). The conceptual model for flow and transport in the EBS will be referred to as the ''EBS RT Abstraction'' in this analysis/modeling report (AMR). The scope of this abstraction and report is limited to flow and transport processes. More specifically, this AMR does not discuss elements of the TSPA-SR and TSPA-LA that relate to the EBS but are discussed in other AMRs. These elements include corrosion processes, radionuclide solubility limits, waste form dissolution rates and concentrations of colloidal particles that are generally represented as boundary conditions or input parameters for the EBS RT Abstraction. In effect, this AMR provides the algorithms for transporting radionuclides using the flow geometry and radionuclide concentrations determined by other

  20. Initial Radionuclide Inventories

    Energy Technology Data Exchange (ETDEWEB)

    H. Miller

    2004-09-19

    The purpose of this analysis is to provide an initial radionuclide inventory (in grams per waste package) and associated uncertainty distributions for use in the Total System Performance Assessment for the License Application (TSPA-LA) in support of the license application for the repository at Yucca Mountain, Nevada. This document is intended for use in postclosure analysis only. Bounding waste stream information and data were collected that capture probable limits. For commercially generated waste, this analysis considers alternative waste stream projections to bound the characteristics of wastes likely to be encountered using arrival scenarios that potentially impact the commercial spent nuclear fuel (CSNF) waste stream. For TSPA-LA, this radionuclide inventory analysis considers U.S. Department of Energy (DOE) high-level radioactive waste (DHLW) glass and two types of spent nuclear fuel (SNF): CSNF and DOE-owned (DSNF). These wastes are placed in two groups of waste packages: the CSNF waste package and the codisposal waste package (CDSP), which are designated to contain DHLW glass and DSNF, or DHLW glass only. The radionuclide inventory for naval SNF is provided separately in the classified ''Naval Nuclear Propulsion Program Technical Support Document'' for the License Application. As noted previously, the radionuclide inventory data presented here is intended only for TSPA-LA postclosure calculations. It is not applicable to preclosure safety calculations. Safe storage, transportation, and ultimate disposal of these wastes require safety analyses to support the design and licensing of repository equipment and facilities. These analyses will require radionuclide inventories to represent the radioactive source term that must be accommodated during handling, storage and disposition of these wastes. This analysis uses the best available information to identify the radionuclide inventory that is expected at the last year of last emplacement

  1. Application of radionuclide techniques in evaluation of dilated cardiomyopathy and ischemic cardiomyopathy

    International Nuclear Information System (INIS)

    Tian Yueqin; Liu Xiujie; Shi Rongfang

    2000-01-01

    Objective: To assess the clinical significance of radionuclide techniques in differentiating dilated cardiomyopathy (DCM) from ischemic cardiomyopathy (CAD-CM). Methods: 28 patients (pts) with DCM and 55 pts with CAD-CM were studied. All pts underwent 99 Tc m -MIBI myocardial perfusion SPECT and 18 F-FDG myocardial metabolic PET. 73 pts had 99 Tc m -RBC radionuclide ventriculography and 68 pts had coronary angiography. Results: 23 pts (82%) with DCM showed perfusion abnormalities with mild and not segmental distribution. 52 pts (95%) with CAD-CM showed perfusion abnormalities that distributed along the coronary vessel territories. Perfusion defects were found in 4 pts (14%) with DCM and 45 pts (82%) with CAD-CM (P<0.01). The average perfusion score was 4.5 +- 2.6 in DCM and 9.5 +- 2.9 in CAD-CM, the area of perfusion diminished uptake was significantly smaller in DCM than in CAD-CM (P < 0.001). 2 pts with DCM and 18 pts with CAD-CM had metabolic defect. The patterns of perfusion/metabolic imaging showed mismatch in most pts with CAD-CM but match in pts with DCM. The LVEF in pts with DCM and CAD-CM was decreased but no significant difference between DCM and CAD-CM was observed. The RVEF in pts with DCM was significantly lower than that in pts with CAD-CM (32.4% +- 13.9% vs 40.9% +- 15.4%, P < 0.05). Conclusions: The radionuclide techniques showed to be helpful for distinguishing DCM from CAD-CM. The discriminate analysis revealed that segmental perfusion abnormality and RVEF were the most important factors for differentiation of DCM from CAD-CM

  2. Clinical evaluation of segmental wall motion by radionuclide cardioangiography in the patients with myocardial infarction

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Kozuka, Takahiro

    1980-01-01

    To detect segmental wall motion of left ventricle is useful to identify the size and location of infarcted area in coronary arteries diseases. In this study, segmental wall motion by radionuclide cardioangiography were evaluated to compare with contrast left ventriculography in fifty patients of myocardial infarction. Segmental wall motion in RAO position by first pass method, in LAO position by multi-gated method were evaluated using an Anger camera and on-line minicomputer system by following methods; ED, ES images, sequential images, edge display, regional ejection fraction and movie imaging system (MIS). The percent agreements of segmental wall motion by RI and LVG were 84% in 350 segments of 50 cases. In all segments, segments 4, 6, 7 were better agreements than other segments. For the degree of wall motion, skinesis and dyskinesis were good agreements in both methods, while hypokinesia was slightly poor agreement (62%). On the other hand, the size of infarction, that is, percent thallium defect area was good correlated with radionuclide left ventricular ejection fraction (r = -0.855 in anterior infarction, r = -0.646 in inferior infarction). From these data, wall motion was thought to be closely related with left ventricular function, therefore, regional ejection fraction in seven areas in left ventricular image was developed and compared with segmental wall motion in left ventriculogram according to the classification of A.H.A. Comittee Report. The value of regional ejection fraction is 0.29, 0.40, 0.60 in akinesis, hypokinesis and normal. In conclusion, radionuclide cardioangiography is useful in the detection of abnormal segmental wall motion as noninvasive methods. (author)

  3. Fukushima Daiichi Radionuclide Inventories

    Energy Technology Data Exchange (ETDEWEB)

    Cardoni, Jeffrey N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jankovsky, Zachary Kyle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-01

    Radionuclide inventories are generated to permit detailed analyses of the Fukushima Daiichi meltdowns. This is necessary information for severe accident calculations, dose calculations, and source term and consequence analyses. Inventories are calculated using SCALE6 and compared to values predicted by international researchers supporting the OECD/NEA's Benchmark Study on the Accident at Fukushima Daiichi Nuclear Power Station (BSAF). Both sets of inventory information are acceptable for best-estimate analyses of the Fukushima reactors. Consistent nuclear information for severe accident codes, including radionuclide class masses and core decay powers, are also derived from the SCALE6 analyses. Key nuclide activity ratios are calculated as functions of burnup and nuclear data in order to explore the utility for nuclear forensics and support future decommissioning efforts.

  4. Radionuclide table. Pt. 1

    International Nuclear Information System (INIS)

    Legrand, Jean; Perolat, J.-P.; Lagoutine, Frederic; Le Gallic, Yves.

    The evaluation of the following 29 radionuclides is presented: 22 Na, 24 Na, sup(24m)Na, 51 Cr, 54 Mn, 57 Co, 58 Co, sup(58m)Co, 60 Co, sup(60m)Co, 75 Se, 103 Ru, sup(103m)Rh, sup(110m)Ag- 110 Ag, 109 Cd, 125 Sb, sup(125mTe), 125 I, 133 Xe, sup(133m)Xe, 131 Cs, 134 Cs, sup(134m)Cs, 139 Ce, 144 Ce- 144 Pr, 144 Pr, 169 Er, 186 Re, 203 Hg. The introduction contains a brief description of radioactive processes and the evaluation rules followed. The best values and associated uncertainties are given for each radionuclide for the major parameters of the decay scheme and the radiation intensities emitted, together with a decay table. Gamma, X-rays and sometimes conversion electron spectra are also provided [fr

  5. Radionuclide co-precipitation

    International Nuclear Information System (INIS)

    Bruno, J.; Sandino, A.

    1987-12-01

    The thermodynamic and kinetic behaviour of the minor components of the spent fuel matrix has been theoretically and experimentally investigated. Two different situations have been studied: Part I, the near field scenario, where the release and migration of the minor components is dependent on the solubility behaviour of UO 2 (s); Part II, the far field, where the solubility and transport of the radionuclides is related to the major geochemical processes occurring. (orig.)

  6. Radionuclide fate and effects

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The studies reported here deal with the full range of contaminant behavior and fate, from the initial physicochemical factors that govern radionuclide availability in terrestrial and aquatic environments to studies of contaminant transport by biological means. By design, we focus more on the biologically and chemically mediated transport processes and food-chain pathways than on the purely physical forms of contaminant transport, such as transport by wind and water

  7. BIPM comparison BIPM.RI(II)-K1.Zn-65 of activity measurements of the radionuclide 65Zn for the BARC (India) with linked results for the CCRI(II)-K2.Zn-65 comparison

    International Nuclear Information System (INIS)

    Michotte, C.; Ratel, G.; Courte, S.; Joseph, L.

    2015-01-01

    A new participation in the BIPM.RI(II)-K1.Zn-65 comparison has been added to the previous results. A link has been made to the CCRI(II)-K2.Zn-65 comparison held in 2003 through the measurement of all ampoules of the K2 comparison in the International Reference System (SIR) at the BIPM before despatch to the participants. This has produced a revised value for the key comparison reference value (KCRV), calculated using the power-moderated weighted mean. Six NMIs used the K2 comparison to update their degree of equivalence. The degrees of equivalence between each equivalent activity measured in the International Reference System (SIR) and the KCRV have been calculated and the results are given in the form of a table for the remaining two NMIs in the BIPM.RI(II)-K1.Zn-65 comparison and the 17 other participants in the CCRI(II)-K2.Zn-65 comparison. A graphical presentation is also given. (authors)

  8. Geochemistry and radionuclide migration

    International Nuclear Information System (INIS)

    Isherwood, D.

    1978-01-01

    Theoretically, the geochemical barrier can provide a major line of defense in protecting the biosphere from the hazards of nuclear waste. The most likely processes involved are easily identified. Preliminary investigations using computer modeling techniques suggest that retardation is an effective control on radionuclide concentrations. Ion exchange reactions slow radionuclide migration and allow more time for radioactive decay and dispersion. For some radionuclides, solubility alone may limit concentrations to less than the maximum permissible now considered acceptable by the Federal Government. The effectiveness of the geochemical barrier is ultimately related to the repository site characteristics. Theory alone tells us that geochemical controls will be most efficient in an environment that provides for maximum ion exchange and the precipitation of insoluble compounds. In site selection, consideration should be given to rock barriers with high ion exchange capacity that might also act as semi-permeable membranes. Also important in evaluating the site's potential for effective geochemical controls are the oxidation potentials, pH and salinity of the groundwater

  9. Radionuclides in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Howard, B.J.; Kennedy, V.H.; Nelson, A.

    1983-06-01

    A bibliographical database has been developed to provide quick access to research and background literature in the field of radioecology. This is a development of an earlier database described by Nelson (Bocock 1981). ITE's particular fields of interest have led to a subject bias in the bibliography towards studies in Cumbria, especially those concerned with radionuclides originating from the reprocessing plant at Sellafield, and towards ecological research studies that are complementary to radionuclide studies. Other subjects covered, include the chemistry of radionuclides, budgets and transfers within ecosystems and techniques for the analysis of environmental samples. ITE's research objectives have led to the establishment of a specialized database which is intended to complement rather than compete with the large international databases made available by suppliers such as IRS-DIALTECH or DIALOG. Currently the database holds about 1900 references which are stored on a 2 1/2 megabyte hard disk on a Digital PDP11/34 computer operating under a time shared system. The references follow a standard format. (author)

  10. Radionuclides in marine organisms

    International Nuclear Information System (INIS)

    Honda, Teruyuki

    2001-01-01

    The concentration and accumulation of radionuclides in marine organisms were explained in this paper. Secular change of the radioactivity concentration of 137 Cs in seaweed in coastal area of Japan showed more than 5Bq/kg-fresh in the first half of 1960, but decreased less than 1 Bq/kg-fresh after then and attained to less than 0.1 Bq/kg-fresh in 1990s. However, the value increased a while in 1986, which indicated the effect of Chernobyl accident. The accident increased 137 Cs of shellfish near Japan. The concentration of 239+240 Pu was the lowest value in muscles of fish, but increased from 1.7 to 42.3 mBq/kg wet wt in seaweed in 1999. 99 Tc concentration of seaweed showed from 100 to 1000 times as much as that of seawater. Radionuclides in the Irish Sea are originated from Sellafield reprocessing plant. The concentration factors of macro-algae and surface water fish (IAEA,1985) were shown. Analytical results of U in 61 kinds of marine organs showed that the concentration was different in the part of organ. The higher concentration of U was observed in hard tissue of fish. The concentration factor was different between chemical substances with the same radionuclides. (S.Y.)

  11. Proficiency testing for radionuclides

    International Nuclear Information System (INIS)

    Faanhof, A.; Kotze, O.; Louw, I.

    2010-01-01

    Proficiency testing in general is only useful when it suites a certain purpose. With regards to radionuclides basically three fields of interest can be identified: (I)Foodstuffs-Introduced in the early 1960's to monitor the fall-out of nuclear tests and eventually the pathway to foodstuffs fit for human consumption. The demand for analysis increased substantially after the Chernobyl accident. (II) Natural radioactivity-Associated with mining and mineral processing of uranium and thorium baring mineral resources throughout the world where the radionuclides from the natural uranium and thorium decay series are found to pose concern for professional and public exposure. (III) Artificial radioactivity-This category covers mostly the long-lived nuclides generated by nuclear fission of the fuel used in nuclear power plants, research reactors and nuclear bomb tests. All three categories require a specific approach for laboratories to test their ability to analyze specific radio nuclides of interest in a variety of matrices. In this lecture I will give a compiled overview of the required radioanalytical skills, analysis sensitivity needed and radionuclides of interest, with more specific emphasis on QAQC of water sources and the recommended monitoring approach. And provide information on available reference materials and organizations/institutes that provide regular exercises for participating laboratories. I will also briefly communicate on the advantages and disadvantages of ISO/IEC 17025 accreditation for test laboratories, which is these days a prerequisite in national and international trade especially where foodstuffs and mineral products are concerned.

  12. Radionuclides in thyroid cancer

    International Nuclear Information System (INIS)

    Mahadev, V.

    1980-01-01

    The three main areas of application of radionuclides in thyroid disease will be reviewed. Firstly thyroid radionuclide imaging in thyroid swellings, in relationship to lumps in the neck and ectopic thyroid tissue such as retrosternal goitre, and lingual goitre will be described. Future developments in the field including tomographic scanning, using the coded aperture method, and fluorescent scans and ultrasound are reviewed. The second area of application is the assessment and evaluation of thyroid function and the therapy of Grave's Disease and Plummer's Disease using radioiodine. The importance of careful collection of the line of treatment, results of treatment locally and the follow-up of patients after radioiodine therapy will be described. The third area of application is in the diagnosis and therapy of thyroid cancer. Investigation of thyroid swelling, and the diagnosis of functioning metastases are reported. The therapeutic iodine scan as the sole evidence of functioning metastatic involvement is recorded. Histological thyroid cancer appears to be increasingly encountered in clinical practice and the plan of management in relation to choice of cases for therapeutic scanning is discussed with case reports. Lastly the role of whole body scanning in relationship to biochemical markers is compared. In the changing field of nuclear medicine radionuclide applications in thyroid disease have remained pre-eminent and this is an attempt to reassess its role in the light of newer developments and local experience in the Institute of Radiotherapy, Oncology and Nuclear Medicine. (author)

  13. Right heart ventriculography

    Science.gov (United States)

    Angiography - right heart ... moved forward into the right side of the heart. As the catheter is advanced, the doctor can ... is injected into the right side of the heart. It helps the cardiologist determine the size and ...

  14. Chapter 2. Radionuclides in the biosphere

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with role of radionuclides in the biosphere. Chapter consists of next parts: (1) Natural radionuclides in biosphere; (2) Man-made radionuclides in the biosphere; (3) Ecologically important radionuclides; (4) Natural background; (5) Radiotoxicity and (6) Paths of transfer of radionuclides from the source to human

  15. History of medical radionuclide production.

    Science.gov (United States)

    Ice, R D

    1995-11-01

    Radionuclide production for medical use originally was incidental to isotope discoveries by physicists and chemists. Once the available radionuclides were identified they were evaluated for potential medical use. Hevesy first used 32P in 1935 to study phosphorous metabolism in rats. Since that time, the development of cyclotrons, linear accelerators, and nuclear reactors have produced hundreds of radionuclides for potential medical use. The history of medical radionuclide production represents an evolutionary, interdisciplinary development of applied nuclear technology. Today the technology is represented by a mature industry and provides medical benefits to millions of patients annually.

  16. EBS Radionuclide Transport Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    J.D. Schreiber

    2005-08-25

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in ''Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration'' (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment for the license application (TSPA-LA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA-LA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport

  17. EBS Radionuclide Transport Abstraction

    International Nuclear Information System (INIS)

    J.D. Schreiber

    2005-01-01

    The purpose of this report is to develop and analyze the engineered barrier system (EBS) radionuclide transport abstraction model, consistent with Level I and Level II model validation, as identified in ''Technical Work Plan for: Near-Field Environment and Transport: Engineered Barrier System: Radionuclide Transport Abstraction Model Report Integration'' (BSC 2005 [DIRS 173617]). The EBS radionuclide transport abstraction (or EBS RT Abstraction) is the conceptual model used in the total system performance assessment for the license application (TSPA-LA) to determine the rate of radionuclide releases from the EBS to the unsaturated zone (UZ). The EBS RT Abstraction conceptual model consists of two main components: a flow model and a transport model. Both models are developed mathematically from first principles in order to show explicitly what assumptions, simplifications, and approximations are incorporated into the models used in the TSPA-LA. The flow model defines the pathways for water flow in the EBS and specifies how the flow rate is computed in each pathway. Input to this model includes the seepage flux into a drift. The seepage flux is potentially split by the drip shield, with some (or all) of the flux being diverted by the drip shield and some passing through breaches in the drip shield that might result from corrosion or seismic damage. The flux through drip shield breaches is potentially split by the waste package, with some (or all) of the flux being diverted by the waste package and some passing through waste package breaches that might result from corrosion or seismic damage. Neither the drip shield nor the waste package survives an igneous intrusion, so the flux splitting submodel is not used in the igneous scenario class. The flow model is validated in an independent model validation technical review. The drip shield and waste package flux splitting algorithms are developed and validated using experimental data. The transport model considers

  18. Osteopetrosis: Radiological & Radionuclide Imaging

    International Nuclear Information System (INIS)

    Sit, Cherry; Agrawal, Kanhaiyalal; Fogelman, Ignac; Gnanasegaran, Gopinath

    2015-01-01

    Osteopetrosis is a rare inherited bone disease where bones harden and become abnormally dense. While the diagnosis is clinical, it also greatly relies on appearance of the skeleton radiographically. X-ray, radionuclide bone scintigraphy and magnetic resonance imaging have been reported to identify characteristics of osteopetrosis. We present an interesting case of a 59-year-old man with a history of bilateral hip fractures. He underwent 99m Tc-methylene diphosphonate whole body scan supplemented with single-photon emission computed tomography/computed tomography of spine, which showed increased uptake in the humeri, tibiae and femora, which were in keeping with osteopetrosis

  19. Modifying radionuclide effects

    International Nuclear Information System (INIS)

    Sasser, L.B.

    1983-01-01

    This project involves a study of the relationship of physiological and environmental factors to the metabolism and effects of radionuclides. We have studied placental transfer and suckling as pathways of americium entry into the newborn or juvenile rat. Rats were injected intravenously with 5 μCi of 241 Am while nulliparous (30 days prior to mating), pregnant (day 19 of gestation), or lactating (1 day after parturition), and subsequent litters were killed to determine 241 Am retention. A deficit in reproductive performance was observed in the group injected before mating, as evidenced by reduced number and weight of offspring

  20. Radionuclides in the sea

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1971-07-01

    Water covers a little more than two-thirds of the earth's surface. What is thrown into the sea from a ship may be washed up on a shore thousands of miles away; wastes discharged into the seas or into rivers flowing into them can affect marine life and possibly also the health of man. The study, prevention and control of pollution of the seas and oceans by radionuclides introduced as by-products of man's use of nuclear energy is thus of global interest. (author)

  1. Sherlock Holmes for radionuclides

    International Nuclear Information System (INIS)

    Schmitzer, C.

    2002-01-01

    At the end of 2001 ARC Seibersdorf research has taken the management of the first worldwide certified laboratory to control the realization of the international Comprehensive Nuclear Test Ban Treaty (CTBT). Altogether there will be 16 CTBT certified laboratories worldwide; therefore a global network of radionuclides measurements stations and test laboratories as well as seismic, radiation and hydroacustic measurements stations is necessary . In the future air samples will be taken from these stations and analyzed in one of these certified laboratories, when appears the suspicion that an atomic test was carried out. (nevyjel)

  2. Radionuclide accumulation in green and brown macroalgae at the Bulgarian Black Sea coast

    International Nuclear Information System (INIS)

    Strezov, A.; Nonova, T.

    2005-01-01

    The concentration of technogenic and natural radionuclides were measured in brown and green macroalgae from the Bulgarian Black Sea coast for the period 1996 and 2003 using low-level gamma spectroscopy. Mean values and concentration range for the studied species enables the comparison of the nuclide content in macroalgae showing that brown algae accumulate the studied radionuclides to a higher extent. (author)

  3. Biventricular function in sickle-cell anemia: radionuclide angiographic and thallium-201 scintigraphic evaluation

    International Nuclear Information System (INIS)

    Manno, B.V.; Burka, E.R.; Hakki, A.H.; Manno, C.S.; Iskandrian, A.S.; Noone, A.M.

    1983-01-01

    Left ventricular (LV) and right ventricular (RV) function were evaluated at rest and during exercise using radionuclide ventriculography in 10 patients, aged 19-53 years, with sickle-cell anemia (SCA). Seven patients were in New York Heart Association functional class I and 3 were in class II. The resting LV ejection fraction (EF) was normal in 9 patients and the resting RVEF was normal in 4. LV dilation and high cardiac output were observed in 6 patients at rest. The LVEF during exercise was normal in all 10 patients, whereas only 2 patients had normal RVEF at rest and during exercise. The LVEF was lower in patients with SCA at rest (54 +/- 4% versus 61 +/- 6%, p less than 0.001) and exercise (66 +/- 4% versus 74 +/- 6%, p less than 0.001) than in 42 age-matched normal subjects. Rest thallium-201 images from 9 patients showed abnormal RV uptake in 8 and normal LV uptake in 8. Thus, in adult patients with SCA, LV function was normal during exercise in all patients and at rest in all but 1 patient. The LVEF, however, was lower than that in age-matched normal subjects. RV function was abnormal in most patients at rest and during exercise. RV thallium-201 uptake suggested pressure or volume overload (or both), most likely due to pulmonary vaso-occlusive complications of the disease

  4. Radionuclide concentrations in white sturgeon from the Columbia River. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Dauble, D.D.; Price, K.R.; Poston, T.M.

    1993-11-01

    The objectives of this study were to (1) review and summarize historical data on radionuclide concentrations in white sturgeon from the Columbia River, (2) determine present-day radionuclide tissue burdens from different locations in the Columbia River, and (3) compare historical data with current data. We first reviewed and summarized the historical literature on radionuclide concentrations in white sturgeon from the Hanford Reach. Field studies were then conducted to evaluate the relationship among sample locations, age/length of white sturgeon, and present radionuclide tissue burdens. Results and comparisons are discussed in the remainder of this report.

  5. Improved radionuclide method for the diagnosis of gastroesophageal reflux and aspiration in children (milk scan)

    International Nuclear Information System (INIS)

    Heyman, S.; Kirkpatrick, J.A.; Winter, H.S.; Treves, S.

    1979-01-01

    A radionuclide study using technetium-99m-labelled milk feeding is described for the detection of gastroesophageal reflux and aspiration in children. A comparison of findings in 39 patients referred for both radiographic and radionuclide studies showed that barium studies were positive in 25.6% and radionuclide studies in 59% of cases, reflecting the sensitivity of the radionuclide technique. This technique is also physiological and allows prolonged patient monitoring. It is simple to perform and should prove useful in the evaluation of patients suspected of having gastroesophageal reflux and aspiration

  6. Discussion on monitoring items of radionuclides in influents from nuclear power plants

    International Nuclear Information System (INIS)

    Zhang Yanxia; Li Jin; Liu Jiacheng; Han Shanbiao; Yu Zhengwei

    2014-01-01

    For the radionuclide monitoring items of effluents from nuclear power plant, this paper makes some comparisons and analysis from three aspects of the international atomic energy general requirements, the routine radionuclide measurement items of China's nuclear power plant and effluents low level radionuclide experimental research results. Finally, it summarizes the necessary items and recommended items of the radionuclide monitoring of effluents from nuclear power plant, which can provide references for the radioactivity monitoring activities of nuclear power plant effluent and the supervisions of regulatory departments. (authors)

  7. Radionuclide Therapy. Chapter 19

    Energy Technology Data Exchange (ETDEWEB)

    Flux, G.; Du, Yong [Royal Marsden Hospital and Institute of Cancer Research, Surrey (United Kingdom)

    2014-12-15

    Cancer has been treated with radiopharmaceuticals since the 1940s. The radionuclides originally used, including 131I and 32P, are still in use. The role of the physicist in radionuclide therapy encompasses radiation protection, imaging and dosimetry. Radiation protection is of particular importance given the high activities of the unsealed sources that are often administered, and must take into account medical staff, comforters and carers, and, as patients are discharged while still retaining activity, members of the public. Regulations concerning acceptable levels of exposure vary from country to country. If the administered radiopharmaceutical is a γ emitter, then imaging can be performed which may be either qualitative or quantitative. While a regular system of quality control must be in place to prevent misinterpretation of image data, qualitative imaging does not usually rely on the image corrections necessary to determine the absolute levels of activity that are localized in the patient. Accurate quantitative imaging is dependent on these corrections and can permit the distribution of absorbed doses delivered to the patient to be determined with sufficient accuracy to be clinically beneficial.

  8. Intervention procedures for radionuclides

    International Nuclear Information System (INIS)

    Adelstein, S.J.

    1991-01-01

    As in the case of smoking and lung cancer, for large radionuclide releases, an ounce of prevention is worth a pound of cure. On the other hand, we feel compelled to do something sensible after an accident even if the principal benefit of intervention may be to comfort the population at risk. Of course, for populations near the site of an accident, evacuation should be considered, but it is unreasonable to apply this measure to distant populations, e.g., large segments of the European community could not be moved about as we observe the shifting of a radioactive cloud in response to changing winds. If the radionuclides are delivered as particulates, bringing people indoors and employing primitive air filters can temporarily reduce exposures, but these stratagems are not very effective against gaseous or volatile elements. What, then, can be done for populations downwind of a radioactive release whose air, water, and/or food supply are, or are about to become contaminated? 5 refs

  9. A meshless approach to radionuclide transport calculations

    International Nuclear Information System (INIS)

    Perko, J.; Sarler, B.

    2005-01-01

    Over the past thirty years numerical modelling has emerged as an interdisciplinary scientific discipline which has a significant impact in engineering and design. In the field of numerical modelling of transport phenomena in porous media, many commercial codes exist, based on different numerical methods. Some of them are widely used for performance assessment and safety analysis of radioactive waste repositories and groundwater modelling. Although they proved to be an accurate and reliable tool, they have certain limitations and drawbacks. Realistic problems often involve complex geometry which is difficult and time consuming to discretize. In recent years, meshless methods have attracted much attention due to their flexibility in solving engineering and scientific problems. In meshless methods the cumbersome polygonization of calculation domain is not necessary. By this the discretization time is reduced. In addition, the simulation is not as discretization density dependent as in traditional methods because of the lack of polygon interfaces. In this work fully meshless Diffuse Approximate Method (DAM) is used for calculation of radionuclide transport. Two cases are considered; First 1D comparison of 226 Ra transport and decay solved by the commercial Finite Volume Method (FVM) and Finite Element Method (FEM) based packages and DAM. This case shows the level of discretization density dependence. And second realistic 2D case of near-field modelling of radionuclide transport from the radioactive waste repository. Comparison is made again between FVM based code and DAM simulation for two radionuclides: Long-lived 14 C and short-lived 3 H. Comparisons indicate great capability of meshless methods to simulate complex transport problems and show that they should be seriously considered in future commercial simulation tools. (author)

  10. Some parameters of radionuclide kinetics

    International Nuclear Information System (INIS)

    Prokof'ev, O.N.; Smirnov, V.A.; Belen'kij, E.I.

    1978-01-01

    Numerical values of the rates of radionuclide absorption into, and elimination from, bovine organs were determined. Kinetic rate constants of radionuclides such as 89 Sr, 99 Mo, 131 I, 132 Tl, and 140 Be were calculated. The calculations were done for muscle, liver, and kidney

  11. Radionuclide - Soil Organic Matter Interactions

    DEFF Research Database (Denmark)

    Carlsen, Lars

    1985-01-01

    Interactions between soil organic matter, i.e. humic and fulvic acids, and radionuclides of primary interest to shallow land burial of low activity solid waste have been reviewed and to some extent studied experimentally. The radionuclides considered in the present study comprise cesium, strontium...

  12. Chapter 13. Radionuclides in medicine

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with problems connected with using of radionuclides in medicine. Methods of treatment with using of radionuclides are reviewed. Chapter consists of next parts: (1) Remotion of thyroid gland; (2) Treatment of cerebrally tumour in nuclear reactor; (3) Artificial heart

  13. Table of radionuclides (Vol. 5 - A = 22 to 244)

    International Nuclear Information System (INIS)

    Be, M.M.; Chiste, V.; Dulieu, C.; Mougeot, X.; Browne, E.; Chechev, V.; Kuzmenko, N.; Kondev, F.; Luca, A.; Galan, M.; Arinc, A.; Huang, X.

    2010-01-01

    This monograph is one of several published in a series by the Bureau International des Poids et Mesures (BIPM) on behalf of the Comite Consultatif des Rayonnements Ionisants (CCRI), previously known as the Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants (CCEMRI). The aim of this series of publications is to review topics that are of importance for the measurement of ionizing radiation and especially of radioactivity, in particular those techniques normally used by participants in international comparisons. It is hoped that these publications will prove to be useful reference volumes both for those who are already engaged in this field and for those who are approaching such measurements for the first time. The purpose of this monograph is to present the recommended values of nuclear and decay data for a wide range of radionuclides. Activity measurements for more than forty of these radionuclides have already been the subject of comparisons under the auspices of Section II of the CCRI. The material for this monograph is now covered in four volumes. The first two volumes contain the primary recommended data relating to half-lives, decay modes, x-rays, gamma-rays, electron emissions; alpha- and beta-particle transitions and emissions, and their uncertainties for a set of sixty-eight radionuclides: Volume 1 for those radionuclides with mass number up to and including 150, and Volume 2 for those radionuclides with mass number over 150. Volume 3 contains the equivalent data for twenty-six additional radionuclides and re-evaluations for 125 Sb and 153 Sm; Volume 4 contains the data for a further thirty-one radionuclides with re-evaluation for 226 Ra while the present Volume 5 includes 17 new radionuclide evaluations and 8 re-evaluations of previous data as identified in the contents page. The data have been collated and evaluated by an international working group (Decay Data Evaluation Project) led by the LNE-LNHB. The evaluators have agreed on the

  14. Radionuclide transverse section imager

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1980-01-01

    A radioisotope scanning apparatus for use in nuclear medicine is described in detail. The apparatus enables the quantification and spatial location of the radioactivity in a body section of a patient to be determined with high sensitivity. It consists of an array of highly focussed collimators arranged such that adjacent collimators move in the same circumferential but opposite radial directions. The explicit movements of the gantry are described in detail and may be controlled by a general purpose computer. The use of highly focussed collimators allows both a reasonable solid angle of acceptance and also high target to background images; additionally, dual radionuclide pharmaceutical studies can be performed simultaneously. It is claimed that the high sensitivity of the system permits the early diagnosis of pathological changes and the images obtained show accurately the location and shape of physiological abnormalities. (UK)

  15. Radioactivity, radionuclides, radiation

    CERN Document Server

    Magill, Joseph

    2005-01-01

    RADIOACTIVITY – RADIONUCLIDES – RADIATION is suitable for a general audience interested in topical environmental and human health radiological issues such as radiation exposure in aircraft, food sterilisation, nuclear medicine, radon gas, radiation dispersion devices ("dirty bombs")… It leads the interested reader through the three Rs of nuclear science, to the forefront of research and developments in the field. The book is also suitable for students and professionals in the related disciplines of nuclear and radiochemistry, health physics, environmental sciences, nuclear and astrophysics. Recent developments in the areas of exotic decay modes (bound beta decay of ‘bare’ or fully ionized nuclei), laser transmutation, nuclear forensics, radiation hormesis and the LNT hypothesis are covered. Atomic mass data for over 3000 nuclides from the most recent (2003) evaluation are included.

  16. Deep sea radionuclides

    International Nuclear Information System (INIS)

    Kanisch, G.; Vobach, M.

    1993-01-01

    Every year since 1979, either in sping or in summer, the fishing research vessel 'Walther Herwig' goes to the North Atlantic disposal areas of solid radioactive wastes, and, for comparative purposes, to other areas, in order to collect water samples, plankton and nekton, and, from the deep sea bed, sediment samples and benthos organisms. In addition to data on the radionuclide contents of various media, information about the plankton, nekton and benthos organisms living in those areas and about their biomasses could be gathered. The investigations are aimed at acquiring scientifically founded knowledge of the uptake of radioactive substances by microorganisms, and their migration from the sea bottom to the areas used by man. (orig.) [de

  17. Radionuclide reporter gene imaging

    International Nuclear Information System (INIS)

    Min, Jung Joon

    2004-01-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases

  18. Radionuclide reporter gene imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Joon [School of Medicine, Chonnam National Univ., Gwangju (Korea, Republic of)

    2004-04-01

    Recent progress in the development of non-invasive imaging technologies continues to strengthen the role of molecular imaging biological research. These tools have been validated recently in variety of research models, and have been shown to provide continuous quantitative monitoring of the location(s), magnitude, and time-variation of gene expression. This article reviews the principles, characteristics, categories and the use of radionuclide reporter gene imaging technologies as they have been used in imaging cell trafficking, imaging gene therapy, imaging endogenous gene expression and imaging molecular interactions. The studies published to date demonstrate that reporter gene imaging technologies will help to accelerate model validation as well as allow for clinical monitoring of human diseases.

  19. Natural radionuclides in groundwaters

    International Nuclear Information System (INIS)

    Laul, J.C.

    1990-01-01

    The U-234 and Th-230 radionuclides are highly retarded by factors of 10 4 to 10 5 in basalt groundwater (Hanford) and briny groundwaters from Texas and geothermal brine from the Salton Sea Geothermal Field (SSGF). In basalt groundwaters (low ionic strength), Ra is highly sorbed, while in brines (high ionic strength), Ra is soluble. This is probably because the sorption sites are saturated with Na + and Cl - ions and RaCl 2 is soluble in brines. Pb-210 is soluble in SSGF brine, probably as a chloride complex. The U-234/Th-230 ratios in basalt groundwaters and brines from Texas and SSGF are nearly unity, indicating that U is in the +4 state, suggesting a reducing environment for these aquifers. 19 refs., 3 figs

  20. Natural radionuclides in groundwaters

    International Nuclear Information System (INIS)

    Laul, J.C.

    1992-01-01

    The 234 U and 230 Th radionuclides are highly retarded by factors of 10 4 to 10 5 in basalt groundwater (Hanford) and briny groundwaters from Texas, and geothermal brine form the Salton Sea Geothermal Field (SSGF). In basalt groundwaters (low ionic strength), Ra is highly sorbed, while in brines (high ionic strength), Ra is soluble. This is probably because the sorption sites are saturated with Na + and Cl - ions, and RaCl 2 is soluble in brines. 210 Pb is soluble in SSGF brine, probably as a chloride complex. The 234 U/ 230 Th ratios in basalt groundwaters and brines from Texas and SSGF are nearly unity, indicating that U is in the +4 state, suggesting a reducing environment for these aquifers. (author) 19 refs.; 3 figs

  1. Significant Radionuclides Determination

    Energy Technology Data Exchange (ETDEWEB)

    Jo A. Ziegler

    2001-07-31

    The purpose of this calculation is to identify radionuclides that are significant to offsite doses from potential preclosure events for spent nuclear fuel (SNF) and high-level radioactive waste expected to be received at the potential Monitored Geologic Repository (MGR). In this calculation, high-level radioactive waste is included in references to DOE SNF. A previous document, ''DOE SNF DBE Offsite Dose Calculations'' (CRWMS M&O 1999b), calculated the source terms and offsite doses for Department of Energy (DOE) and Naval SNF for use in design basis event analyses. This calculation reproduces only DOE SNF work (i.e., no naval SNF work is included in this calculation) created in ''DOE SNF DBE Offsite Dose Calculations'' and expands the calculation to include DOE SNF expected to produce a high dose consequence (even though the quantity of the SNF is expected to be small) and SNF owned by commercial nuclear power producers. The calculation does not address any specific off-normal/DBE event scenarios for receiving, handling, or packaging of SNF. The results of this calculation are developed for comparative analysis to establish the important radionuclides and do not represent the final source terms to be used for license application. This calculation will be used as input to preclosure safety analyses and is performed in accordance with procedure AP-3.12Q, ''Calculations'', and is subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (DOE 2000) as determined by the activity evaluation contained in ''Technical Work Plan for: Preclosure Safety Analysis, TWP-MGR-SE-000010'' (CRWMS M&O 2000b) in accordance with procedure AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities''.

  2. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  3. Geomorphological applications of environmental radionuclides

    International Nuclear Information System (INIS)

    Quine, T.A.; Walling, D.

    1998-01-01

    Geomorphologists have shown increasing interest in environmental radionuclides since pioneering studies by Ritchie and McHenry in the USA and Campbell, Longmore and Loughran in Australia. Environmental radionuclides have attracted this interest because they provide geomorphologists with the means to trace sediment movement within the landscape. They, therefore, facilitate investigation of subjects at the core of geomorphology, namely the rates and patterns of landscape change. Most attention has been focussed on the artificial radionuclide caesium-137 ( 137 Cs) but more recently potential applications of the natural radionuclides lead-210 ( 210 Pb) and beryllium-7( 7 Be) have been investigated (Walling et al., 1995; Wallbrink and Murray, 1996a, 1996b). The origin, characteristics and applications of these radionuclides are summarised. These radionuclides are of value as sediment tracers because of three important characteristics: a strong affinity for sediment; a global distribution and the possibility of measurement at low concentration. Geomorphological applications of environmental radionuclides provide unique access to detailed qualitative data concerning landscape change over a range of timescales

  4. Gated blood pool tomography for the evaluation of global and regional left ventricular function in comparison to planar techniques and echocardiography.

    Science.gov (United States)

    Canclini, S; Terzi, A; Rossini, P; Vignati, A; La Canna, G; Magri, G C; Pizzocaro, C; Giubbini, R

    2001-01-01

    Multigated radionuclide ventriculography (MUGA) is a simple and reliable tool for the assessment of global systolic and diastolic function and in several studies it is still considered a standard for the assessment of left ventricular ejection fraction. However the evaluation of regional wall motion by MUGA is critical due to two-dimensional imaging and its clinical use is progressively declining in favor of echocardiography. Tomographic MUGA (T-MUGA) is not widely adopted in clinical practice. The aim of this study was to compare T-MUGA to planar MUGA (P-MUGA) for the assessment of global ejection fraction and to transthoracic echocardiography for the evaluation of regional wall motion. A 16-segment model was adopted for the comparison with echo regional wall motion. For each one of the 16 segments the normal range of T-MUGA ejection fraction was quantified and a normal data file was defined; the average value -2.5 SD was used as the lower threshold to identify abnormal segments. In addition, amplitude images from Fourier analysis were quantified and considered abnormal according to three different thresholds (25, 50 and 75% of the maximum). In a study group of 33 consecutive patients the ejection fraction values of T-MUGA highly correlated with those of P-MUGA (r = 0.93). The regional ejection fraction (according to the normal database) and the amplitude analysis (50% threshold) allowed for the correct identification of 203/226 and 167/226 asynergic segments by echocardiography, and of 269/302 and 244/302 normal segments, respectively. Therefore sensitivity, specificity and overall accuracy to detect regional wall motion abnormalities were 90, 89, 89% and 74, 81, 79% for regional ejection fraction and amplitude analysis, respectively. T-MUGA is a reliable tool for regional wall motion evaluation, well correlated with echocardiography, less subjective and able to provide quantitative data.

  5. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: a preliminary study

    International Nuclear Information System (INIS)

    Mariano-Goulart, D.; Boudousq, V.; Comte, F.; Eberle, M.C.; Zanca, M.; Kotzki, P.O.; Rossi, M.; Piot, C.; Raczka, F.; Davy, J.M.

    2001-01-01

    The aim of this preliminary study was to evaluate the accuracy of left and right ventricular output computed from a semi-automatic processing of tomographic radionuclide ventriculography data (TRVG) in comparison with the conventional thermodilution method. Twenty patients with various heart diseases were prospectively included in the study. Thermodilution and TRVG acquisitions were carried out on the same day for all patients. Analysis of gated blood pool slices was performed using a watershed-based segmentation algorithm. Right and left ventricular output measured by TRVG correlated well with the measurements obtained with thermodilution (r=0.94 and 0.91 with SEE=0.38 and 0.46 l/min, respectively, P<0.001). The limits of agreement for TRVG and thermodilution measurements were -0.78-1.20 l/min for the left ventricle and -0.34-1.16 l/min for the right ventricle. No significant difference was found between the results of TRVG and thermodilution with respect to left ventricular output (P=0.09). A small but significant difference was found between right ventricular output measured by TRVG and both left ventricular output measured by TRVG (mean difference=0.17 l/min, P=0.04) and thermodilution-derived cardiac output (mean difference=0.41 l/min, P=0.0001). It is concluded that the watershed-based semi-automatic segmentation of TRVG slices provides non-invasive measurements of right and left ventricular output and stroke volumes at equilibrium, in routine clinical settings. Further studies are necessary to check whether the accuracy of these measurements is good enough to permit correct assessment of intracardiac shunts. (orig.)

  6. Radionuclides in Canada goose eggs

    International Nuclear Information System (INIS)

    Rickard, W.H.; Sweany, H.A.

    1975-01-01

    Low levels of radionuclides were measured in Canada goose eggs taken from deserted nests from Columbia River islands on the Energy Research and Development Administration's Hanford Reservation. Potassium-40, a naturally occurring radionuclide, was the most abundant radionuclide measured in egg contents and egg shell. Strontium-90 was incorporated into egg shells and cesium-137 into inner egg contents. Manganese-54, cobalt-60, and zinc-65 were more abundant in inner egg contents than in egg shell. Cerium-144 was detected in egg shell but not in inner shell

  7. Radionuclide migration in water reservoirs

    International Nuclear Information System (INIS)

    Rodionova, L.F.

    1983-01-01

    Toxicity degree and radiation effect of different radionuclides depend on multiple factors, whose interaction can strengthen or weaken the effects through the mechanism of nuclide accumulation by hydrobiontes. Stage of development of an aquatic organism, its age, mass and sex as well as lifetime and residence time of the organism in the given medium are of importance. The radionuclide build up depends on illumination, locale of the bioobject residence, on the residence nature. The concentration of radionuclides in aquatic organisms and bionts survival depend on a season, temperature of the residence medium, as well as salinity and mineral composition of water influence

  8. Artificial radionuclides in soil, flora and fauna

    International Nuclear Information System (INIS)

    Marej, A.N.

    1984-01-01

    Sources and ways of soil contamination by radionuclides, as well as the main regularities of radionuclide behaviour in soils, are discussed. Ways of radionuclide uptake by plants are discussed in detail, since radionuclide contamination of vegetation, and agricultural plants and pastures in particular, is one of the main factors, determining sanitary value of environmental contamination by radioactive substances

  9. Radionuclide methods in pediatric cardiology

    International Nuclear Information System (INIS)

    Reich, O.; Ruth, C.; Samanek, M.

    1990-01-01

    The use of radionuclide methods in pediatric cardiology is discussed for non-invasive evaluation of myocardial function and perfusion, regional lung perfusion and ventilation, and for measuring central and peripheral hemodynamics. (H.W.). 16 refs

  10. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Bovaird, Chase C.; Jansik, Danielle P.; Wellman, Dawn M.; Wood, Marcus I.

    2011-09-30

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. The information present in the report provides data that (1) measures the effect of concrete wasteform properties likely to influence radionuclide migration; and (2) quantifies the rate of carbonation of concrete materials in a simulated vadose zone repository.

  11. Radionuclides in the food chain

    International Nuclear Information System (INIS)

    Harley, J.H.; Schmidt, G.D.

    1988-01-01

    Radionuclides in the Food Chain reviews past experience in meeting the challenge of radionuclide contamination of foodstuffs and water sources and, in the wake of the reactor accidents at Chernobyl and Three Mile Island, presents current concepts and programs relating to measurement, surveillance, effects, risk management, evaluation guidelines, and control and regulatory activities. This volume, based on a symposium sponsored by the International Life Sciences Institute in association with the International Institute for Applied Systems Analysis, which brought together both radiation experts and food industry policymakers, examines such vital topics as structural problems in large-scale crisis-managment systems; dose assessment from man-made sources; international recommendations on radiation protection; airborne contamination, as well as aquatic and soilborne radionuclides; food-chain contamination from testing nuclear devices; long-term health effects of radionuclides in food and water supplies; and use of mathematical models in risk assessment and management. (orig.)

  12. Surface diffusion of sorbed radionuclides

    International Nuclear Information System (INIS)

    Berry, J.A.; Bond, K.A.

    1991-01-01

    Surface diffusion has in the past been invoked to explain rates of radionuclide migration which were greater than those predicted. Results were generally open to interpretation but the possible existence of surface diffusion, whereby sorbed radionuclides could potentially migrate at much enhanced rates, necessitated investigation. In this work through-diffusion experiments have shown that although surface diffusion does exist for some nuclides, the magnitude of the phenomenon is not sufficient to affect repository safety assessment modelling. (author)

  13. Radionuclide generators for biomedical applications

    International Nuclear Information System (INIS)

    Finn, R.D.; Molinski, V.J.; Hupf, H.B.; Kramer, H.

    1983-10-01

    This document reviews the chemical literature of those radionuclide generators that have gained or appear to possess utility in medical imaging. The text represents a conscientious effort to peruse the scientific literature through 1980. The intent of this work is to provide a reference point for the investigator who is interested in the development of a particular generator system and the refinements which have been reported. Moreover, the incorporation of the particular daughter radionuclide into a suitable radiodiagnostic agent is presented

  14. Radionuclide metrology: traceability and response to a radiological accident

    Energy Technology Data Exchange (ETDEWEB)

    Tauhata, L.; Cruz, P.A.L. da; Silva, C.J. da; Delgado, J.U.; Oliveira, A.E. de; Oliveira, E.M. de; Poledna, R.; Loureiro, J. dos S.; Ferreira Filho, A.L.; Silva, R.L. da; Filho, O. L.T.; Santos, A.R.L. dos; Veras, E.V. de; Rangel, J. de A.; Quadros, A.L.L.; Araújo, M.T.F. de; Souza, P.S. de; Ruzzarim, A.; Conceição, D.A. da; Iwahara, A., E-mail: palcruz@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    In the case of a radiological accident, there are characteristic phases: discovery and initial assistance with first aid; the triage and monitoring of the affected population; the release of the affected people; forward the victims to medical care; as well as the preparation of the report on the accident. In addition, studies and associated researches performed in the later period. Monitors, dosimeters and measuring systems should be calibrated by contaminating radionuclide standards. The radioactive sources used must be metrologically reliable. In Brazil, this function is performed by LNMRI/IRD/CNEN, designated by INMETRO, which Radionuclide Metrology Laboratory is responsible for the standardization and supply of radioactive sources in diverse geometries and matrices. This laboratory has a stock of radionuclide solutions with controlled environmental variables for the preparation of sources, which are calibrated and standardized by mean of primary and secondary systems. It is also responsible for the dissemination of standards and, in order to establish the metrological traceability of national standards, participates in international key-comparisons promoted by BIPM and regional metrology organizations. Internally, it promotes the National Comparison Programs for laboratories for the analysis of environmental samples and the traceability for producing centers of radiopharmaceuticals and Nuclear Medicine Services in the country. The paper presents the demand for {sup 137}Cs related to the radioactive accident in Goiania/Brazil and the significant results for the main radionuclides standardized by the Radionuclide Metrology Laboratory for international key-comparisons and national comparisons to provide metrological traceability. With the obtained results, the LNMRI of Brazil integrates the international metrology BIPM network and fulfills its function of supplying, with about a hundred of radioactive standards, the country's needs in different applications

  15. Radionuclide metrology: traceability and response to a radiological accident

    International Nuclear Information System (INIS)

    Tauhata, L.; Cruz, P.A.L. da; Silva, C.J. da; Delgado, J.U.; Oliveira, A.E. de; Oliveira, E.M. de; Poledna, R.; Loureiro, J. dos S.; Ferreira Filho, A.L.; Silva, R.L. da; Filho, O. L.T.; Santos, A.R.L. dos; Veras, E.V. de; Rangel, J. de A.; Quadros, A.L.L.; Araújo, M.T.F. de; Souza, P.S. de; Ruzzarim, A.; Conceição, D.A. da; Iwahara, A.

    2017-01-01

    In the case of a radiological accident, there are characteristic phases: discovery and initial assistance with first aid; the triage and monitoring of the affected population; the release of the affected people; forward the victims to medical care; as well as the preparation of the report on the accident. In addition, studies and associated researches performed in the later period. Monitors, dosimeters and measuring systems should be calibrated by contaminating radionuclide standards. The radioactive sources used must be metrologically reliable. In Brazil, this function is performed by LNMRI/IRD/CNEN, designated by INMETRO, which Radionuclide Metrology Laboratory is responsible for the standardization and supply of radioactive sources in diverse geometries and matrices. This laboratory has a stock of radionuclide solutions with controlled environmental variables for the preparation of sources, which are calibrated and standardized by mean of primary and secondary systems. It is also responsible for the dissemination of standards and, in order to establish the metrological traceability of national standards, participates in international key-comparisons promoted by BIPM and regional metrology organizations. Internally, it promotes the National Comparison Programs for laboratories for the analysis of environmental samples and the traceability for producing centers of radiopharmaceuticals and Nuclear Medicine Services in the country. The paper presents the demand for 137 Cs related to the radioactive accident in Goiania/Brazil and the significant results for the main radionuclides standardized by the Radionuclide Metrology Laboratory for international key-comparisons and national comparisons to provide metrological traceability. With the obtained results, the LNMRI of Brazil integrates the international metrology BIPM network and fulfills its function of supplying, with about a hundred of radioactive standards, the country's needs in different applications

  16. Radionuclide migration in soils

    Energy Technology Data Exchange (ETDEWEB)

    Demir, M [Ingenieurgesellschaft Bonnenberg und Drescher, Juelich (Germany, F.R.)

    1979-01-01

    Unplanned releases from a nuclear installation - e.g., leakage from a storage tank or other incident - can result in the escape of contaminants such as U, Pu, Cs, Sr, T etc. Nuclide transport through the ground is governed by characteristics of the subsurface hydrology and the specific nuclides under consideration. Unsaturated soil layers result in a transport rate so low as to negligible. Radionuclides reaching the ground water are assumed to endanger human life because of potential uncontrolled ingestion. The most dangerous nuclides are long-lived and not absorbed, or very poorly absorbed, in the soil. During migration of nuclides through saturated soil layers, the concentration can be reduced by dilution. Preliminary results indicate that tritium is spread with ground water velocity. Its concentration can be reduced only by diffusion, dispersion and radioactive decay. Alpha-emitters are strongly retained velocities of alpha-emitters are approximately one thousandth (10/sup -3/) that of T. Transport velocities of Cs and Sr are approximately one hundreth (10/sup -2/) and one tenth (10/sup -1/) that of T respectively.

  17. Radionuclide migration in soils

    International Nuclear Information System (INIS)

    Demir, M.

    1979-01-01

    Unplanned releases from a nuclear installation - e.g., leakage from a storage tank or other incident - can result in the escape of contaminants such as U, Pu, Cs, Sr, T etc. Nuclide transport through the ground is governed by characteristics of the subsurface hydrology and the specific nuclides under consideration. Unsaturated soil layers result in a transport rate so low as to negligible. Radionuclides reaching the ground water are assumed to endanger human life because of potential uncontrolled ingestion. The most dangerous nuclides are long-lived and not absorbed, or very poorly absorbed, in the soil. During migration of nuclides through saturated soil layers, the concentration can be reduced by dilution. Preliminary results indicate that tritium is spread with ground water velocity. Its concentration can be reduced only by diffusion, dispersion and radioactive decay. Alpha-emitters are strongly retained velocities of alpha-emitters are approximately one thousandth (10 -3 ) that of T. Transport velocities of Cs and Sr are approximately one hundreth (10 -2 ) and one tenth (10 -1 ) that of T respectively. (orig./HP) [de

  18. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  19. Radionuclide brain scanning

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.

    1992-01-01

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ''allied advances'' with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  20. Radionuclides migration or isolation?

    International Nuclear Information System (INIS)

    Toulhoat, P.; Grambow, B.; Simoni, E.

    2005-01-01

    After 20 years of research, the chemical behaviour of actinides and fission products in nuclear waste disposal environments is much better understood. Consistent thermodynamic data have been gathered and allow much more accurate previsions. Through the considerable development of analytical spectroscopy, including time resolved laser fluorescence and X ray absorption, a better understanding of the chemical reactivity (complexation, sorption) of actinides and fission products at a molecular scale has been possible. Chemically reducing conditions are found in most selected disposal host rock formations, generally chosen for their high sorption capacity (clays); such conditions favour the chemical confinement of most radionuclides through precipitation or sorption. Low permeability host rocks participate to this confinement, as convective fluxes are lower than diffusive fluxes. The most recent performance assessment exercises have taken into account the recent progress of knowledge in the chemical evolution of the near field. They show that the dose rates at the outlet are far lower than existing recommendations for normal and most altered evolution scenarios. (authors)

  1. Radionuclide salivary gland imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1981-01-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific

  2. Radionuclide brain scanning

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H

    1993-12-31

    At one stage of medical imaging development, radionuclide brain scanning was the only technique available for imaging of the brain. Advent of CT and MRI pushed it to the background. It regained some of the grounds lost to ``allied advances`` with the introduction of brain perfusion radiopharmaceuticals. Positron emission tomography is a promising functional imaging modality that at present will remain as a research tool in special centres in developed countries. However, clinically useful developments will gradually percolate from PET to SPECT. The non-nuclear imaging methods are totally instrument dependent; they are somewhat like escalators, which can go that far and no further. Nuclear imaging has an unlimited scope for advance because of the new developments in radiopharmaceuticals. As the introduction of a radiopharmaceutical is less costly than buying new instruments, the recent advances in nuclear imaging are gradually perfusing through the developing countries also. Therefore, it is essential to follow very closely PET developments because what is research today might become routine tomorrow

  3. Removal of some radionuclides from water by bioaccumulation

    Energy Technology Data Exchange (ETDEWEB)

    Miskovic, D.; Conkic, L.; Dalmacija, B.; Gantar, M. (Trg D. Obradvica 3, Novi Sad (Yugoslavia). Faculty of Sciences)

    1992-01-01

    First objective of this study was to investigate the application of biologically activated carbon (BAC) as well as its comparison to adsorption, with the aim of removing some radionuclides from water. The isotopes Cs[sup 134] and Cs[sup 137] were bioaccumulated by BAC up to 50%, while the I[sup 131] isotope was only physicochemically adsorbed (about 40%). Also, the process of radionuclides (Cs[sup 137], Ce[sup 139], Co[sup 57], Co[sup 60]) fixation on blue-green algae (Nostoc sp.) was investigated. The kinetics of the removal of these radionuclides from water was recorded. It was found that after a contact period of about half an hour 40-70% of the activity was removed. (Author).

  4. Artificial radionuclides in the atmosphere over Lithuania

    International Nuclear Information System (INIS)

    Lujaniene, G.; Sapolaite, J.; Remeikis, V.; Lujanas, V.; Aninkevicius, V.

    2006-01-01

    %). Accuracy and precision of analysis were tested using NIST SRM No 4350B and 4357 as well as in intercomparison runs, organized by the Riso National Laboratory, Denmark. Precision of 1 37Cs measurements by gamma spectrometry was ≤ 7% at 2σ, Pu ≤ 8 %, Am ≤ 10 %. 2 40Pu/ 2 39Pu ratio was determined by ICP-MS. For determination of chemical association of radionuclides with aerosol particles the sequential extraction methods were used. Measurements performed in Vilnius and Preila indicated transfer of resuspention and combustion products after the forest and peat bog fires in the Ukraine and Belarus when activity concentrations of 1 37Cs in the atmosphere increased up to 200μBq/m 3 . The measurements carried out on aerosol samples collected in Vilnius in 1997-1999 indicated the presence of alpha emitting radionuclides. The activity concentrations of 2 39, 2 40Pu and 2 41Am ranged from 0.4 to 18 and from 0.3 to 9.7 nBq/m 3 , respectively. The origin of contamination source was identified using meteorological data of backward trajectories, characteristic speciation, activity and atom ratio of radionuclides. For comparison measurements were performed on aerosol samples collected during the Chernobyl accident and the contaminated Chernobyl soil. In some samples the high activity ratio of 2 38Pu/ 2 39, 2 40Pu up to 0.5 was observed. The presence of the Chernobyl derived plutonium was confirmed by ICPMS (atom ratio 2 40Pu/ 2 39Pu up to 0.40 was found). Thus, the Chernobyl accident resulted in contamination of large areas of the Earth's surface and forests by radioactive substances. The redistribution of radionuclides mainly of Cs, from these regions to less contaminated areas takes place during the forest fires, because the aerosol particles generated in a different phase of fire have predominantly a submicronic size and are enriched by the volatile Cs due to its evaporation and condensation on condensation nuclei in the atmosphere (the increase of Cs/Sr and Cs/Pu ratio

  5. Anthropogenic radionuclides in the environment

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Q; Weng, J; Wang, J

    2007-11-15

    Studies of radionuclides in the environment have entered a new era with the renaissance of nuclear energy and associated fuel reprocessing, geological disposal of high-level nuclear wastes, and concerns about national security with respect to nuclear non-proliferation. This work presents an overview of anthropogenic radionuclide contamination in the environment, as well as the salient geochemical behavior of important radionuclides. We first discuss the following major anthropogenic sources and current development that contribute to the radionuclide contamination of the environment: (1) nuclear weapons program; (2) nuclear weapons testing; (3) nuclear power plants; (4) commercial fuel reprocessing; (5) geological repository of high-level nuclear wastes, and (6) nuclear accidents. Then, we summarize the geochemical behavior for radionuclides {sup 99}Tc, {sup 129}I, and {sup 237}Np, because of their complex geochemical behavior, long half-lives, and presumably high mobility in the environment. Biogeochemical cycling and environment risk assessment must take into account speciation of these redox-sensitive radionuclides.

  6. Speciation and transport of radionuclides in ground water

    International Nuclear Information System (INIS)

    Robertson, D.E.; Toste, A.P.; Abel, K.H.; Cowan, C.E.; Jenne, E.A.; Thomas, C.W.

    1984-01-01

    Studies of the chemical speciation of a number of radionuclides migrating in a slightly contaminated ground water plume are identifying the most mobile species and providing an opportunity to test and/or validate geochemical models of radionuclide transport in ground waters. Results to date have shown that most of the migrating radionuclides are present in anionic or nonionic forms. These include anionic forms of 55 Fe, 60 Co, /sup 99m/Tc, 106 Ru, 131 I, and nonionic forms of 63 Ni and 125 Sb. Strontium-70 and a small fraction of the mobile 60 Co are the only cationic radionuclides which have been detected moving in the ground water plume beyond 30 meters from the source. A comparison of the observed chemical forms with the predicted species calculated from modeling thermodynamic data and ground water chemical parameters has indicated a good agreement for most of the radioelements in the system, including Tc, Np, Cs, Sr, Ce, Ru, Sb, Zn, and Mn. The discrepancies between observed and calculated solutions species were noted for Fe, Co, Ni and I. Traces of Fe, Co, and Ni were observed to migrate in anionic or nonionic forms which the calculations failed to predict. These anionic/nonionic species may be organic complexes having enhanced mobility in ground waters. The radioiodine, for example, was shown to behave totally as an anion but further investigation revealed that 49-57% of this anionic iodine was organically bound. The ground water and aqueous extracts of trench sediments contain a wide variety of organic compounds, some of which could serve as complexing agents for the radionuclides. These results indicate the need for further research at a variety of field sites in defining precisely the chemical forms of the mobile radionuclide species, and in better understanding the role of dissolved organic materials in ground water transport of radionuclides

  7. Model for radionuclide transport in running waters

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Karin; Elert, Mark [Kemakta Konsult AB, Stockholm (Sweden)

    2005-11-15

    Two sites in Sweden are currently under investigation by SKB for their suitability as places for deep repository of radioactive waste, the Forsmark and Simpevarp/Laxemar area. As a part of the safety assessment, SKB has formulated a biosphere model with different sub-models for different parts of the ecosystem in order to be able to predict the dose to humans following a possible radionuclide discharge from a future deep repository. In this report, a new model concept describing radionuclide transport in streams is presented. The main difference from the previous model for running water used by SKB, where only dilution of the inflow of radionuclides was considered, is that the new model includes parameterizations also of the exchange processes present along the stream. This is done in order to be able to investigate the effect of the retention on the transport and to be able to estimate the resulting concentrations in the different parts of the system. The concentrations determined with this new model could later be used for order of magnitude predictions of the dose to humans. The presented model concept is divided in two parts, one hydraulic and one radionuclide transport model. The hydraulic model is used to determine the flow conditions in the stream channel and is based on the assumption of uniform flow and quasi-stationary conditions. The results from the hydraulic model are used in the radionuclide transport model where the concentration is determined in the different parts of the stream ecosystem. The exchange processes considered are exchange with the sediments due to diffusion, advective transport and sedimentation/resuspension and uptake of radionuclides in biota. Transport of both dissolved radionuclides and sorbed onto particulates is considered. Sorption kinetics in the stream water phase is implemented as the time scale of the residence time in the stream water probably is short in comparison to the time scale of the kinetic sorption. In the sediment

  8. Model for radionuclide transport in running waters

    International Nuclear Information System (INIS)

    Jonsson, Karin; Elert, Mark

    2005-11-01

    Two sites in Sweden are currently under investigation by SKB for their suitability as places for deep repository of radioactive waste, the Forsmark and Simpevarp/Laxemar area. As a part of the safety assessment, SKB has formulated a biosphere model with different sub-models for different parts of the ecosystem in order to be able to predict the dose to humans following a possible radionuclide discharge from a future deep repository. In this report, a new model concept describing radionuclide transport in streams is presented. The main difference from the previous model for running water used by SKB, where only dilution of the inflow of radionuclides was considered, is that the new model includes parameterizations also of the exchange processes present along the stream. This is done in order to be able to investigate the effect of the retention on the transport and to be able to estimate the resulting concentrations in the different parts of the system. The concentrations determined with this new model could later be used for order of magnitude predictions of the dose to humans. The presented model concept is divided in two parts, one hydraulic and one radionuclide transport model. The hydraulic model is used to determine the flow conditions in the stream channel and is based on the assumption of uniform flow and quasi-stationary conditions. The results from the hydraulic model are used in the radionuclide transport model where the concentration is determined in the different parts of the stream ecosystem. The exchange processes considered are exchange with the sediments due to diffusion, advective transport and sedimentation/resuspension and uptake of radionuclides in biota. Transport of both dissolved radionuclides and sorbed onto particulates is considered. Sorption kinetics in the stream water phase is implemented as the time scale of the residence time in the stream water probably is short in comparison to the time scale of the kinetic sorption. In the sediment

  9. Ultra-sensitive radionuclide spectrometry. Radiometrics and mass spectrometry synergy

    International Nuclear Information System (INIS)

    Povinec, P.P.

    2005-01-01

    Recent developments in radiometrics and mass spectrometry techniques for ultra-sensitive analysis of radionuclides in the marine environment are reviewed. In the radiometrics sector the dominant development has been the utilization of large HPGe detectors in underground laboratories with anti-cosmic or anti-Compton shielding for the analysis of short and medium-lived radionuclides in the environment. In the mass spectrometry sector, applications of inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS) for the analysis of long-lived radionuclides in the environment are the most important recent achievements. The recent developments do not only considerably decrease the detection limits for several radionuclides (up to several orders of magnitude), but they also enable to decrease sample volumes so that sampling, e.g., of the water column can be much easier and more effective. A comparison of radiometrics and mass spectrometry results for the analysis of radionuclides in the marine environment shows a reasonable agreement - within quoted uncertainties, for wide range of activities and different sample matrices analyzed. (author)

  10. Radionuclides from past uranium mining in rivers of Portugal.

    Science.gov (United States)

    Carvalho, Fernando P; Oliveira, João M; Lopes, Irene; Batista, Aleluia

    2007-01-01

    During several decades and until a few years ago, uranium mines were exploited in the Centre of Portugal and wastewaters from uranium ore milling facilities were discharged into river basins. To investigate enhancement of radioactivity in freshwater ecosystems, radionuclides of uranium and thorium series were measured in water, sediments, suspended matter, and fish samples from the rivers Vouga, Dão, Távora and Mondego. The results show that these rivers carry sediments with relatively high naturally occurring radioactivity, and display relatively high concentrations of radon dissolved in water, which is typical of a uranium rich region. Riverbed sediments show enhanced concentrations of radionuclides in the mid-section of the Mondego River, a sign of past wastewater discharges from mining and milling works at Urgeiriça confirmed by the enhanced values of (238)U/(232)Th radionuclide ratios in sediments. Radionuclide concentrations in water, suspended matter and freshwater fish from that section of Mondego are also enhanced in comparison with concentrations measured in other rivers. Based on current radionuclide concentrations in fish, regular consumption of freshwater species by local populations would add 0.032 mSv a(-1) of dose equivalent (1%) to the average background radiation dose. Therefore, it is concluded that current levels of enhanced radioactivity do not pose a significant radiological risk either to aquatic fauna or to freshwater fish consumers.

  11. Dosimetry in radionuclide therapy

    International Nuclear Information System (INIS)

    Riccabona, G.

    2001-01-01

    While it is known that therapeutic effects of radionuclides are due to absorbed radiation dose and to radiosensitivity, individual dosimetry in 'Gy' is practiced rarely in clinical Nuclear Medicine but 'doses' are described in 'mCi' or 'MBq', which is only indirectly related to 'Gy' in the target. To estimate 'Gy', the volume of the target, maximum concentration of the radiopharmaceutical in it and residence time should be assessed individually. These parameters can be obtained usually only with difficulty, involving possibly also quantitative SPET or PET, modern imaging techniques (sonography, CT, MRT), substitution of y- or positron emitting radiotracers for β - emitting radiopharmaceuticals as well as whole-body distribution studies. Residence time can be estimated by obtaining data on biological half-life of a comparable tracer and transfer of these data in the physical characteristics of the therapeutic agent. With all these possibilities for gross dosimetry the establishment of a dose-response-relation should be possible. As distribution of the radiopharmaceutical in lesions is frequently inhomogenous and microdosimetric conditions are difficult to assess in vivo as yet, it could be observed since decades that empirically set, sometimes 'fixed' doses (mCi or MBq) can also be successful in many diseases. Detailed dosimetric studies, however, are work- and cost-intensive. Nevertheless, one should be aware at a time when more sophisticated therapeutic possibilities in Nuclear Medicine arise, that we should try to estimate radiation dose (Gy) in our new methods even as differences in individual radiosensitivity cannot be assessed yet and studies to define individual radiosensitivity in lesions should be encouraged. (author)

  12. Radionuclide Sensors for Water Monitoring

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.; DeVol, Timothy A.

    2004-01-01

    Radionuclide contamination in the soil and groundwater at U.S. Department of Energy (DOE) sites is a severe problem that requires monitoring and remediation. Radionuclide measurement techniques are needed to monitor surface waters, groundwater, and process waters. Typically, water samples are collected and transported to an analytical laboratory, where costly radiochemical analyses are performed. To date, there has been very little development of selective radionuclide sensors for alpha- and beta-emitting radionuclides such as 90Sr, 99Tc, and various actinides of interest. The objective of this project is to investigate novel sensor concepts and materials for sensitive and selective determination of beta- and alpha-emitting radionuclide contaminants in water. To meet the requirements for loW--level, isotope-specific detection, the proposed sensors are based on radiometric detection. As a means to address the fundamental challenge of the short ranges of beta and alpha particle s in water, our overall approach is based on localization of preconcentration/separation chemistries directly on or within the active area of a radioactivity detector. Automated microfluidics is used for sample manipulation and sensor regeneration or renewal. The outcome of these investigations will be the knowledge necessary to choose appropriate chemistries for selective preconcentration of radionuclides from environmental samples, new materials that combine chemical selectivity with scintillating properties, new materials that add chemical selectivity to solid-state diode detectors, new preconcentrating column sensors, and improved instrumentation and signal processing for selective radionuclide sensors. New knowledge will provide the basis for designing effective probes and instrumentation for field and in situ measurements

  13. Inverse problem in radionuclide transport

    International Nuclear Information System (INIS)

    Yu, C.

    1988-01-01

    The disposal of radioactive waste must comply with the performance objectives set forth in 10 CFR 61 for low-level waste (LLW) and 10 CFR 60 for high-level waste (HLW). To determine probable compliance, the proposed disposal system can be modeled to predict its performance. One of the difficulties encountered in such a study is modeling the migration of radionuclides through a complex geologic medium for the long term. Although many radionuclide transport models exist in the literature, the accuracy of the model prediction is highly dependent on the model parameters used. The problem of using known parameters in a radionuclide transport model to predict radionuclide concentrations is a direct problem (DP); whereas the reverse of DP, i.e., the parameter identification problem of determining model parameters from known radionuclide concentrations, is called the inverse problem (IP). In this study, a procedure to solve IP is tested, using the regression technique. Several nonlinear regression programs are examined, and the best one is recommended. 13 refs., 1 tab

  14. Radionuclide Retention in Concrete Wasteforms

    Energy Technology Data Exchange (ETDEWEB)

    Wellman, Dawn M.; Jansik, Danielle P.; Golovich, Elizabeth C.; Cordova, Elsa A.

    2012-09-24

    Assessing long-term performance of Category 3 waste cement grouts for radionuclide encasement requires knowledge of the radionuclide-cement interactions and mechanisms of retention (i.e., sorption or precipitation); the mechanism of contaminant release; the significance of contaminant release pathways; how wasteform performance is affected by the full range of environmental conditions within the disposal facility; the process of wasteform aging under conditions that are representative of processes occurring in response to changing environmental conditions within the disposal facility; the effect of wasteform aging on chemical, physical, and radiological properties; and the associated impact on contaminant release. This knowledge will enable accurate prediction of radionuclide fate when the wasteforms come in contact with groundwater. Data collected throughout the course of this work will be used to quantify the efficacy of concrete wasteforms, similar to those used in the disposal of LLW and MLLW, for the immobilization of key radionuclides (i.e., uranium, technetium, and iodine). Data collected will also be used to quantify the physical and chemical properties of the concrete affecting radionuclide retention.

  15. Radionuclide injury to the lung

    International Nuclear Information System (INIS)

    Dagle, G.E.; Sanders, C.L.

    1984-01-01

    Radionuclide injury to the lung has been studied in rats, hamsters, dogs, mice and baboons. Exposure of the lung to high dose levels of radionuclides produces a spectrum of progressively more severe functional and morphological changes, ranging from radiation pneumonitis and fibrosis to lung tumors. These changes are somewhat similar for different species. Their severity can be related to the absorbed radiation dose (measured in rads) produced by alpha, beta or gamma radiation emanating from various deposited radionuclides. The chemicophysical forms of radionuclides and spatial-temporal factors are also important variables. As with other forms of injury to the lung, repair attempts are highlighted by fibrosis and proliferation of pulmonary epithelium. Lung tumors are the principal late effect observed in experimental animals following pulmonary deposition of radionuclides at dose levels that do not result in early deaths from radiation pneumonitis or fibrosis. The predominant lung tumors described have been of epithelial origin and have been classified, in decreasing frequency of occurrence, as adenocarcinoma, bronchioloalveolar carcinoma, epidermoid carcinomas and combined epidermoid and adenocarcinoma. Mesothelioma and fibrosarcoma have been observed in rats, but less commonly in other species. Hemangiosarcomas were frequently observed in dogs exposed to beta-gamma emitters, and occasionally in rats exposed to alpha emitters. These morphologic changes in the lungs of experimental animals were reviewed and issues relevant to the prediction of human hazards discussed. 88 references

  16. Radionuclides in rodents

    International Nuclear Information System (INIS)

    Taylor, G.N.

    1985-01-01

    Studies are being conducted in mice comparing the toxicity of radium-226, plutonium-239, americium-241, californium-249 and californium-252 in C57B1/Do (albino) mice and the toxicity of americium-241, plutonium-239 and radium-226 in deer mice (Peromyscus maniculatus) and grasshopper mice (Onychomys leucogaster). These experiments will ultimately enable comparison of the toxicity of the above actinide toxicity in man to be made using radium toxicity as the baseline

  17. Method of preparing radionuclide doses

    International Nuclear Information System (INIS)

    Kuperus, J.H.

    1987-01-01

    A method is described of preparing aliquot dosea of a tracer material useful in diagnostic nuclear medicine comprising: storing discrete quantities of a lyophilized radionuclide carrier in separate tubular containers from which air and moisture is excluded, selecting from the tubular containers a container in which is stored a carrier appropriate for a nuclear diagnostic test to be performed, interposing the selected container between the needle and the barrel of a hypodermic syringe, and drawing a predetermined amount of a liquid containing a radionuclide tracer in known concentration into the hypodermic syringe barrel through the hypodermic needle and through the selected container to dissolve the discrete quantity of lyophilized carrier therein to combine the carrier with the radionuclide tracer to form an aliquot dose of nuclear diagnostic tracer material, as needed

  18. Methods of separating short half-life radionuclides from a mixture of radionuclides

    International Nuclear Information System (INIS)

    Bray, L.A.; Ryan, J.L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of 223 Ra and 225 Ac, from a radionuclide ''cow'' of 227 Ac or 229 Th respectively. The method comprises the steps of (a) permitting ingrowth of at least one radionuclide daughter from said radionuclide ''cow'' forming an ingrown mixture; (b) insuring that the ingrown mixture is a nitric acid ingrown mixture; (c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the ''cow'' from at least one radionuclide daughter; (d) insuring that the at least one radionuclide daughter contains the radionuclide product; (e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and (f) recycling the at least one radionuclide daughter by adding it to the ''cow''. In one embodiment the radionuclide ''cow'' is the 227 Ac, the at least one daughter radionuclide is a 227 Th and the product radionuclide is the 223 Ra and the first nitrate form ion exchange column passes the 227 Ac and retains the 227 Th. In another embodiment the radionuclide ''cow'' is the 229 Th, the at least one daughter radionuclide is a 225 Ra and said product radionuclide is the 225 Ac and the 225 Ac and nitrate form ion exchange column retains the 229 Th and passes the 225 Ra/Ac. 8 figs

  19. Producing new radionuclides for medicine

    International Nuclear Information System (INIS)

    Michaut, C.

    2009-01-01

    The Arronax cyclotron, a new particle accelerator dedicated to the production of radionuclides for medicine and research has been commissioned in Nantes (France). Because of its unique features: an energy of 70 MeV and an intensity of 750 μA, Arronax will produce radionuclides that can not be produce in present cyclotrons. Among others it will produce Strontium-82 and Germanium-68 that are the precursors for Rubidium-82 and Gallium-68 respectively. 20 per cent of the research works will be dedicated to other domains like radioactive wastes, the radiation biological damage and the radiation damage on electronic devices. (A.C.)

  20. Radionuclide migration in geological formations

    International Nuclear Information System (INIS)

    Barbreau, A.; Heremans, R.; Skytte Jensen, B.

    1980-01-01

    Radioactive waste disposal into geological formation is based on the capacity of rocks to confine radioactivity for a long period of time. Radionuclide migration from the repository to the environment depends on different mechanisms and phenomena whose two main ones are groundwater flow and the retention and ion-exchange property of rocks. Many studies are underway presently in EEC countries concerning hydrodynamic characteristics of deep geological formations as well as in radionuclide retention capacity and modelling. Important results have already been achieved which show the complexity of some phenomena and further studies shall principally be developed taking into account real conditions of the repository and its environment

  1. Automatic alignment of radionuclide images

    International Nuclear Information System (INIS)

    Barber, D.C.

    1982-01-01

    The variability of the position, dimensions and orientation of a radionuclide image within the field of view of a gamma camera hampers attempts to analyse the image numerically. This paper describes a method of using a set of training images of a particular type, in this case right lateral brain images, to define the likely variations in the position, dimensions and orientation for that type of image and to provide alignment data for a program that automatically aligns new images of the specified type to a standard position, size and orientation. Examples are given of the use of this method on three types of radionuclide image. (author)

  2. Radionuclide techniques for brain imaging

    International Nuclear Information System (INIS)

    Cowan, R.J.; Moody, D.M.

    1984-01-01

    Over the past decade, many of the prime indications for radionuclide brain scanning have become instead indications for CCT, and nuclear medicine studies of the brain have assumed more of a complementary, supportive role. However, there is great promise for improvement in central nervous system radionuclide applications with advances anticipated in both radiopharmaceuticals and instrumentation. Nuclear medicine is continuing to function as a powerful research tool and, in the relatively near future, may regain its role as a major clinical test of the central nervous system

  3. Direct comparison of 68Ga-DOTA-TOC and 18F-FDG PET/CT in the follow-up of patients with neuroendocrine tumour treated with the first full peptide receptor radionuclide therapy cycle

    OpenAIRE

    Nilica, Bernhard; Waitz, Dietmar; Stevanovic, Vlado; Uprimny, Christian; Kendler, Dorota; Buxbaum, Sabine; Warwitz, Boris; Gerardo, Llanos; Henninger, Benjamin; Virgolini, Irene; Rodrigues, Margarida

    2016-01-01

    Purpose To determine the value of 68Ga-DOTA-TOC and 18F-FDG PET/CT for initial and follow-up evaluation of patients with neuroendocrine tumour (NET) treated with peptide receptor radionuclide therapy (PRRT). Methods We evaluated 66 patients who had histologically proven NET and underwent both PRRT and three combined 68Ga-DOTA-TOC and 18F-FDG PET/CT studies. 68Ga-DOTA-TOC PET/CT was performed before PRRT, 3?months after completion of PRRT and after a further 6???9 months. 18F-FDG PET/CT was do...

  4. A new simulation model for calculating the internal exposure of some radionuclides

    Directory of Open Access Journals (Sweden)

    Mahrous Ayman

    2009-01-01

    Full Text Available A new model based on a series of mathematical functions for estimating excretion rates following the intake of nine different radionuclides is presented in this work. The radionuclides under investigation are: cobalt, iodine, cesium, strontium, ruthenium, radium, thorium, plutonium, and uranium. The committed effective dose has been calculated by our model so as to obtain the urinary and faecal excretion rates for each radionuclide. The said model is further validated by a comparison with the widely spread Mondal software and a simulation program. The results obtained show a harmony between the Mondal package and the model we have constructed.

  5. State of radionuclide diagnosis in the USSR (according to the data of science analysis)

    International Nuclear Information System (INIS)

    Arnautov, A.K.; Artamonova, N.O.; Busygina, N.A.; Kornienko, V.V.

    1986-01-01

    Comparison of the results analysing dynamics of publications by radionuclide diagnosis for the late 10-12 years in the occupational magazine ''Medical radiology'', ''Medical abstract magazine'', ''Radiology, roentgenology, oncology'' has been carried out. When comparing publications in ''Medical radiology'', ''Medical abstract magazine'', the expansion of fields for application of radionuclide methods for examination and increase of a number of papers on this subject in allied magazines is detected. According to the specialists' opinion, the further development of radionuclide diagnosis should take the road of development and wide provision of specialized medical institutions with high-sensitive radiometric and dosimetric equipment, short- and ultrashort-living radiopharmaceuticals

  6. A dynamic phantom for radionuclide renography

    International Nuclear Information System (INIS)

    Heikkinen, J.O.

    1999-01-01

    The aim of the study was to develop and test a dynamic phantom simulating radionuclide renography. The phantom consisted of five partly lead covered plastic containers simulating kidneys, heart, bladder and background (soft tissues, liver and spleen). Dynamics were performed with multiple movable steel plates between containers and a gamma camera. Control of the plates is performed manually with a stopwatch following exact time schedules. The containers were filled with activities ( 99m Tc) which produce count rates close to clinical situations. Count rates produced by the phantom were compared with ten clinical renography cases: five 99m Tc MAG3 and five 99m Tc DTPA examinations. Two phantom simulations were repeated three times with separate fillings, acquisitions and analyses. Precision errors as a coefficient of variation (CV) of repeated measurements were calculated and theoretical values were compared with the corresponding measured ones. A multicentre comparison was made between 19 nuclear medicine laboratories and three clinical cases were simulated with the phantom. Correlations between count rates produced by the phantom and clinical studies were r=0.964 for 99m Tc MAG3 (p 99m Tc DTPA (p max was 4.0±1.6%. Images and curves of the scanned phantom were close to a real patient in all 19 laboratories but calculated parameters varied: the difference between theoretical and measured values for T max was 6.8±6.2%. The difference between laboratories is most probably due to variations in acquisition protocols and analysis programs: 19 laboratories with 18 different protocols and 8 different programs. The dynamics were found to be repeatable and suitable for calibration purposes for radionuclide renography programs and protocols as well as for multicentre comparisons. (author)

  7. Content of naturally occurring radionuclides in samples taken from world historical sites

    International Nuclear Information System (INIS)

    Nikolic, J.; Jankovic, M.; Todorovic, D.; Sarap, N.

    2011-01-01

    This paper presents the results of the investigation of naturally occurring radionuclides content in different samples taken from the historical sites in Iran, China, Syria and Jordan. Samples contained different natural materials used in masonry, for making artefacts for personal use as well as water, sand and mud from the Dead sea. The aim was to ascertain the content of naturally occurring radionuclides, calculation of hazard indexes and their comparison to the values recommended and obtained in modern days materials [sr

  8. Determination of alpha radionuclides in fish

    International Nuclear Information System (INIS)

    Pernicka, L.; Matel, L.; Rosskopfova, O.

    2001-01-01

    In atmospheric water, external water and undercurrent the occurrence of radionuclides is usual. It is an important factor of quality of the environment. Plants ingest radionuclides from water and with they everyone. And it arises radioactivity infest food-chain. Radiotoxicity of this radionuclides is very deer sometimes. The sensitive radiochemical procedures for their determination are necessarily important. The poster presents the combined procedure used at our laboratory for determination of alpha radionuclides in biological samples. (authors)

  9. Performance evaluation of commercial radionuclide calibrators in Indonesian hospitals

    International Nuclear Information System (INIS)

    Candra, Hermawan; Marsoem, Pujadi; Wurdiyanto, Gatot

    2012-01-01

    Dose calibrator is one of the supporting equipments in the field of nuclear medicine. At the hospitals, dose calibrator is used for activity measurement of radiopharmaceutical before it is administered to patients. Comparison of activity measurements of 131 I and 99m Tc with dose calibrators was organized in Indonesia during 2007–2010 with the the aim of obtaining information dose calibrator performance in the hospitals. Seven Indonesian hospitals participated in this comparison. The measurement results were evaluated using the E n criteria. The result presented in this paper facilitated the evaluation of dose calibrator performance at several hospitals. - Highlights: ► National comparisons of 131 I and 99m Tc radionuclides in Indonesian hospitals. ► Standardization using a Centronic IG11/A20 4πγ Ionization Chamber and participants using commercial radionuclide calibrators. ► Performance radionuclide calibrator in nuclear medicine in Indonesia. ► Measurement of activity of 99m Tc and 131 I was found satisfactory.

  10. Naturally occurring radionuclides in food

    International Nuclear Information System (INIS)

    Djujic, I.

    1995-01-01

    The naturally occurring radionuclides are the major source of radiation exposure to humans. The principal way of natural radiation exposure is the inhalation of 222 Rn decay products (about 85% of the total). The remainder is equally divided between internally deposited radionuclides, cosmic and terrestrial sources. In the present study, the content of 40 K, 210 Pb, 226 Ra, 230 Th, 232 Th and 238 U in representative food samples (milk, pork, beef, potatoes, wheat and corn flour) and samples of different food items that do not represent entire national production but provide interesting additional data for approximative calculation of naturally occurring radionuclide intake is presented. Daily weight of food eaten, participation of food groups, as well as daily intake by food of mentioned naturally occurring radionuclides in the Serbian diet was obtained on the base of house hold budget surveys. The result obtained for daily intake estimates in mBq for Serbian population are 78.1 ( 40 K), 38.2( 210 Pb), 52.3( 226 Ra), 2.0( 230 Th) and 12.5( 238 U). (author)

  11. 100 Years of radionuclide metrology

    International Nuclear Information System (INIS)

    Judge, S.M.; Arnold, D.; Chauvenet, B.; Collé, R.; De Felice, P.; García-Toraño, E.; Wätjen, U.

    2014-01-01

    The discipline of radionuclide metrology at national standards institutes started in 1913 with the certification by Curie, Rutherford and Meyer of the first primary standards of radium. In early years, radium was a valuable commodity and the aim of the standards was largely to facilitate trade. The focus later changed to providing standards for the new wide range of radionuclides, so that radioactivity could be used for healthcare and industrial applications while minimising the risk to patients, workers and the environment. National measurement institutes responded to the changing demands by developing new techniques for realising primary standards of radioactivity. Looking ahead, there are likely to be demands for standards for new radionuclides used in nuclear medicine, an expansion of the scope of the field into quantitative imaging to facilitate accurate patient dosimetry for nuclear medicine, and an increasing need for accurate standards for radioactive waste management and nuclear forensics. - Highlights: • The driving forces for the development of radionuclide metrology. • Radium standards to facilitate trade of this valuable commodity in the early years. • After 1950, focus changes to healthcare and industrial applications. • National Measurement Institutes develop new techniques, standards, and disseminate the best practice in measurement. • Challenges in nuclear medicine, radioactive waste management and nuclear forensics

  12. Chemistry and analysis of radionuclides

    CERN Document Server

    Lehto, Jukka

    2010-01-01

    Written by chemists for chemists, this is a comprehensive guide to the important radionuclides as well as techniques for their separation and analysis. It introduces readers to the important laboratory techniques and methodologies in the field, providing practical instructions on how to handle nuclear waste and radioactivity in the environment.

  13. Radionuclide migration studies in soil

    International Nuclear Information System (INIS)

    Marumo, J.T.

    1989-01-01

    In this work a brief description about retention and migration parameters of radionuclides in soil, including main methods to determine the distribution coefficient (K) are given. Some of several factors that can act on the migration are also mentioned. (author) [pt

  14. Measurement of radionuclides in waste packages

    Science.gov (United States)

    Brodzinski, R.L.; Perkins, R.W.; Rieck, H.G.; Wogman, N.A.

    1984-09-12

    A method is described for non-destructively assaying the radionuclide content of solid waste in a sealed container by analysis of the waste's gamma-ray spectrum and neutron emissions. Some radionuclides are measured by characteristic photopeaks in the gamma-ray spectrum; transuranic nuclides are measured by neutron emission rate; other radionuclides are measured by correlation with those already measured.

  15. Status report on radionuclide transfer

    International Nuclear Information System (INIS)

    1980-01-01

    At the suggestion of the Federal Minstry of the Interior, in June 1978, a group of scientists from several institutions who are active in the field of radionuclide transfer or are interested in these problems got together. During the discussions of the work team, especially the transfer soil/plants was emphasized. Then the work team set up a status report on the transfer of the radionuclides relevant in the sense of the radiation protection act. The nuclides H 3 and C14, the isotopes of the Sr, J, and Cs, Tc99, the so-called corrosion nuclides Mn54, Fe59, co-isotopes and Zn65, and isotopes of Pu, Am, and Cm were regarded as important for a possible radiation exposition. Recent investigations revealed that also the natural radionuclides Ra226, Po210, and Pb210 should be covered by the investigations. The goal of this status report is to present the level of knowledge on the transfer of these radionuclides to man in a brief form, giving hints at the most important literature. It was requested by the Federal Ministry of the Interior, as fas as possible, to indicate transfer factors which are necessary for the radio-occology act to be decreed according to Para. 45 of the radiation protection act. Another goal of the report was to show the gap in the knowledge on the radio nuclide transfer. This was thought to help to create a basis for the decisions of the Federal Ministry concerning the support of other investigation projects in the field of transfer of radionuclides. (orig./MG) [de

  16. Table of radionuclides (Vol.3 - Α = 3 to 244)

    International Nuclear Information System (INIS)

    Be, M.M.; Chiste, V.; Dulieu, Ch.; Browne, E.; Baglin, C.; Chechev, V.; Kuzmenko; Helmer, R.; Kondev, F.; MacMahon, T.D.; Lee, K.B.

    2006-01-01

    This monograph is one of several published in a series by the Bureau International des Poids et Mesures (BIPM) on behalf of the Comite Consultatif des Rayonnements Ionisants (CCRI), previously known as the Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants (CCEMRI). The aim of this series of publications is to review topics that are of importance for the measurement of ionizing radiation and especially of radioactivity, in particular those techniques normally used by participants in international comparisons. It is hoped that these publications will prove to be useful reference volumes both for those who are already engaged in this field and for those who are approaching such measurements for the first time. The purpose of this monograph, number 5 in the series, is to present the recommended values of nuclear and decay data for a wide range of radionuclides. Activity measurements for more than forty of these radionuclides have already been the subject of comparisons under the auspices of Section II of the CCRI. The material for this monograph is now covered in three volumes. The first two volumes contain the primary recommended data relating to half-lives, decay modes, x-rays, gamma-rays, electron emissions; alpha- and beta-particle transitions and emissions, and their uncertainties for a set of sixty-eight radionuclides, Volume 1 for those radionuclides with mass number up to and including 150 and Volume 2 for those radionuclides with mass number over 150. Volume 3 contains the equivalent data for twenty-six additional radionuclides as listed and re-evaluation for 125 Sb and 153 Sm. The data have been collated and evaluated by an international working group (Decay Data Evaluation Project) led by the LNE-LNHB. The evaluators have agreed on the methodologies to be used and the CD-ROM included with this monograph contains the evaluators' comments for each radionuclide in addition to the data tables included in the monograph. The work involved in

  17. Lifetime health risks from internally deposited beta-emitting radionuclides

    International Nuclear Information System (INIS)

    Boecker, B.B.; Griffith, W.C.; Hahn, F.F.; Nikula, K.J.; Lundgren, D.L.; Muggenburg, B.A.

    1997-01-01

    Much of our knowledge on the lifetime health risks resulting from internal depositions of beta- and gamma-emitting radionuclides has come from studies in laboratory animals conducted to provide information not available from human epidemiological studies. This paper is focused primarily on results of experiments in which laboratory animals (dogs and rodents) were exposed once, briefly, by inhalation or intravenous injection to an individual fission-product radionuclide and were studied for radionuclide metabolism, dosimetry, and lifetime health effects. The relative importance of many dose- and effect-modifying factors was studied. The main long-term biological effects were cancers in the organs and tissues receiving the highest doses. Results for three different patterns of irradiation (skeleton, lung, and whole-body) are presented. The risks of bone cancers produced by 90 Sr are compared with those from 238 Pu in dogs. Lung cancer risks for several beta emitters inhaled in a relatively insoluble form by dogs are compared with results for 144 CeO 2 inhaled by rats. Late-occurring biological effects from the relatively uniform whole-body irradiation from intravenously injected 137 Cs are also presented. In addition to radionuclide-specific results, cross-cutting analyses of these studies provide valuable information on broader issues such as dose protraction, relative biological effectiveness, threshold considerations, and inter-species comparisons including extrapolation to human exposure situations. (authors)

  18. Infant doses from the transfer of radionuclides in mothers' milk

    International Nuclear Information System (INIS)

    Harrison, J.D.; Smith, T.J.; Phipps, A.W.

    2003-01-01

    Assessments of potential internal exposures of the child following radionuclide intakes by the mother require consideration of transfers during lactation as well as during pregnancy. Current ICRP work on internal dosimetry includes the estimation of radiation doses to newborn infants from radionuclides ingested in mothers' milk. Infant doses will be calculated for maternal intakes by ingestion or inhalation of the radionuclides, radioisotopes of 31 elements, for which fetal dose coefficients have been published. In this paper, modelling approaches are examined, concentrating on models developed for iodine, caesium, polonium, alkaline earth elements and the actinides. Comparisons of model predictions show maximum overall transfer to milk following maternal ingestion during lactation of about 30% of ingested activity for 131 I, 20% for 45 Ca and 137 Cs, 10% for 90 Sr, 1% for 210 Po and low values of less than 0.01% for 239 Pu and 241 Am. The corresponding infant doses from milk consumption are estimated in preliminary calculations to be about two to three times the adult dose for 45 Ca and 131 I, 70-80% of the adult dose for 90 Sr, about 40% for 137 Cs, 20% for 210 Po, and 239 Pu and 241 Am. Infant doses from radionuclides in breast milk are compared with doses to the offspring resulting from in utero exposures during pregnancy. (author)

  19. Conditions and processes affecting radionuclide transport

    Science.gov (United States)

    Simmons, Ardyth M.; Neymark, Leonid A.

    2012-01-01

    Characteristics of host rocks, secondary minerals, and fluids would affect the transport of radionuclides from a previously proposed repository at Yucca Mountain, Nevada. Minerals in the Yucca Mountain tuffs that are important for retarding radionuclides include clinoptilolite and mordenite (zeolites), clay minerals, and iron and manganese oxides and hydroxides. Water compositions along flow paths beneath Yucca Mountain are controlled by dissolution reactions, silica and calcite precipitation, and ion-exchange reactions. Radionuclide concentrations along flow paths from a repository could be limited by (1) low waste-form dissolution rates, (2) low radionuclide solubility, and (3) radionuclide sorption onto geological media.

  20. Comparison of the Bioavailability of Waste Laden Soils Using ''In Vivo'' ''In Vitro'' Analytical Methodology and Bioaccessibility of Radionuclides for Refinement of Exposure/Dose Estimates

    Energy Technology Data Exchange (ETDEWEB)

    P. J. Lioy; M. Gallo; P. Georgopoulos; R. Tate; B. Buckley

    1999-09-15

    The bioavailability of soil contaminants can be measured using in vitro or in vivo techniques. Since there was no standard method for intercomparison among laboratories, we compared two techniques for bioavailability estimation: in vitro dissolution and in vivo rat feeding model for a NIST-traceable soil material. Bioaccessibility was measured using a sequential soil extraction in synthetic analogues of human saliva, gastric and intestinal fluids. Bioavailability was measured in Sprague Dawley rats by determining metal levels in the major organs and urine, feces, and blood. Bioaccessibility was found to be a good indicator of relative metal bioavailability. Results are presented from bioaccessible experiments with Cesium in contaminated DOE soils, and total alpha and beta bioaccessibility. The results indicate that the modified methodology for bioaccessibility can be used for specific radionuclide analysis.

  1. Radionuclide transfer from mother to embryo

    International Nuclear Information System (INIS)

    Toader, M.; Vasilache, R.A.; Scridon, R.; Toader, M.L.

    1998-01-01

    The transfer of radionuclides from mother to embryo is still a matter of high interest. Therefore, the relation was investigated between the amount of radionuclides in the embryo and the dietary intake of the mother, this for two scenarios: a recurrent intake of variable amounts of radionuclides, and a long-term intake of a relatively constant amount of radionuclides, the radionuclide being 137 Cs. In the first case, the amount of radionuclides present in the embryo increases with the age of the embryo and with the intake of the mother. In the second case, no correlation could be found between the age of the embryo and its radioactive content; only the correlation between the intake of the mother and the radionuclide content of the embryo remained. (A.K.)

  2. Methodology for implementation of a national metrology net of radionuclides used in nuclear medicine

    International Nuclear Information System (INIS)

    Santos, Joyra Amaral dos

    2004-01-01

    The National Laboratory for Ionizing Radiation Metrology, of the Institute of Radiation Protection and Dosimetry, of the National Commission on Nuclear Energy (IRD/CNEN), comes leading a comparison program for activity measurements of radiopharmaceuticals administered to patients in the Nuclear Medicine Services (NMS) with the purpose to promote the quality control. This work presents a quality assurance program for the performance of such measurements, evaluated in the comparison runs between hospitals and LNMRI, under the statistic point of view and the compliment of regulatory authority norms. The performance of the radionuclides 67 Ga, 123 I, 131 I, 99m Tc and 210 Tl were evaluated and 201 TI have been standardized by absolute methods. Besides, it was established the traceability of the radioactivity standards used in nuclear medicine and a methodology for implementation of a national metrology net of radionuclides. The comparison results prove that the implementation of a radionuclide metrology net is viable, important and feasible. (author)

  3. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  4. Choice of radionuclides for radioimmunotherapy

    International Nuclear Information System (INIS)

    DeNardo, S.J.; Jungerman, J.A.; DeNardo, G.L.; Lagunas-Solar, M.C.; Cole, W.C.; Meares, C.F.

    1985-01-01

    Innumerable questions need to be answered and obstacles overcome before radioimmunotherapy can be generally successful in cancer patients. Major developments have greatly enhanced the likelihood of success. The important development of appropriate radionuclides and radiochemistry for this therapy must be intimately linked with the biological and biochemical realities. All aspects must be considered, such as the specific nature of the antigenic target, the pharmacokinetics of the antibody fragment carrier, the capability of in vivo quantitation of tumor uptake and turnover time, as well as total body kinetics. With this knowledge, then, practical radiochemistry methods can be integrated with the suitable radionuclide choices, and production methods can be developed which will deliver effective and dependable products for patient therapy

  5. Radionuclide transfer in terrestrial animals

    International Nuclear Information System (INIS)

    DiGregorio, D.; Kitchings, T.; Van Voris, P.

    1978-01-01

    The analysis of dispersion of radionuclides in terrestrial food chains, generally, is a series of equations identifying the fractional input and outflow rates from trophic level to trophic level. Data that are prerequisite inputs for these food chain transport models include: (1) identification of specific transport pathway, (2) assimilation at each pathway link, and (3) the turnover rate or retention function by successive receptor species in the appropriate food chain. In this report, assimilation coefficients, biological half-lives, and excretion rates for a wide variety of vertebrate and invertebrate species and radionuclides have been compiled from an extensive search of the available literature. Using the information accumulated from the literature, correlations of nuclide metabolism and body weight are also discussed. (author)

  6. Applications of radionuclides in industry

    International Nuclear Information System (INIS)

    Leveque, P.

    1955-01-01

    After a brief recall of a few concepts (mass number, charge and beams properties) and the description of used detectors (ionization chamber, Geiger-Mueller counter, scintillation counters), some radionuclides applications are described. In a first part, the well-developed applications are presented in three distinct groups: continuous applications such as β and γ gauges (determination hydrogen content of an hydrocarbon and content of an emulsion; discharge of static electricity), discontinuous applications such as radiography and autoradiography, wear or manufacture problems (distribution of a fungicide on tobacco) and finally, applications in research laboratories such as diffusion, exchange and solubility. It also describes the applications which are still in development such as the action of beams on matter (reticulation and degradation of polymers, monomers polymerisation, cold sterilization). In conclusion, few advices on the opportunity of such applications and the choice of the radionuclides are given. (M.P.)

  7. Radionuclide imaging of musculoskeletal infection

    International Nuclear Information System (INIS)

    Palestr, Christopher J.; North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY; Love, Charito

    2007-01-01

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  8. Radionuclide behavior at underground environment

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal.

  9. Radionuclide imaging of musculoskeletal infection

    Energy Technology Data Exchange (ETDEWEB)

    Palestr, Christopher J. [Albert Einstein College of Medicine, Bronx, NY (United States); North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging; E-mail: palestro@lij.edu; Love, Charito [North Shore Long Island Jewish Health System, Manhasset and New Hyde Park, NY (United States). Div. of Nuclear Medicine and Molecular Imaging

    2007-09-15

    Radionuclide imaging studies are routinely used to evaluate patients suspected of having musculoskeletal infection. Three-phase bone imaging is readily available, relatively inexpensive, and very accurate in the setting of otherwise normal bone. Labeled leukocyte imaging should be used in cases of 'complicating osteomyelitis' such as prosthetic joint infection. This test also is useful in clinically unsuspected diabetic pedal osteomyelitis as well as in the neuropathic joint. It is often necessary, however, to perform complementary bone marrow imaging, to maximize the accuracy of labeled leukocyte imaging. In contrast to other regions in the skeleton, labeled leukocyte imaging is not useful for diagnosing spinal osteomyelitis. At the moment, gallium is the preferred radionuclide procedure for this condition and is a useful adjunct to magnetic resonance imaging. FDG-PET likely will play an important role in the evaluation of musculoskeletal infection, especially spinal osteomyelitis, and may replace gallium imaging for this purpose. (author)

  10. Terrestrial pathways of radionuclide particulates

    International Nuclear Information System (INIS)

    Boone, F.W.; Ng, Y.C.

    1981-01-01

    Formulations are developed for computing potential human intake of 13 radionuclides via the terrestrial food chains. The formulations are an extension of the NRC methodology. Specific regional crop and livestock transfer and fractional distribution data from the southern part of the U.S.A. are provided and used in the computation of comparative values with those computed by means of USNRC Regulatory Guide 1.109 formulations. In the development of the model, emphasis was also placed on identifying the various time-delay compartments of the food chains and accounting for all of the activity initially deposited. For all radionuclides considered, except 137 Cs, the new formulations predict lower potential intakes from the total of all food chains combined than do the comparable Regulatory Guide formulations by as much as a factor of 40. For 137 Cs the new formulations predict 10% higher potential intakes. (author)

  11. Fracture occurrence from radionuclides in the skeleton

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd, R.D.; Taylor, G.N.; Miller, S.C.

    2000-06-01

    Because skeletal fractures were an important finding among persons contaminated with {sup 226}Ra, experience with fractures among dogs in the colony was summarized to determine the projected significance for persons contaminated with bone-seeking radionuclides. Comparison by Fisher's Exact Test of lifetime fracture occurrence in the skeletons of beagles injected as young adults suggested that for animals given {sup 226}Ra, {sup 228}Ra, {sup 228}Th, or {sup 239}Pu citrate, there was probably an excess over controls in fractures of the ribs, leg bones, spinous processes, and pelvis (os coxae) plus the mandible for dogs given {sup 226}Ra and the scapulae for dogs given {sup 228}Ra or 228 Th. Regression analysis indicated that significantly elevated fracture occurrence was especially notable at the higher radiation doses, at about 50 Gy average skeletal dose for {sup 239}Pu, 140 Gy for {sup 226}Ra, about 40 Gy for {sup 228}Ra, and more than 15 Gy for {sup 228}Th. The average number of fractures per dog was significantly elevated over that noted in controls for the highest radiation doses of {sup 239}Pu and {sup 226}Ra and for the higher doses of {sup 228}Ra and {sup 228}Th. For those dogs given {sup 90}Sr citrate, there was virtually no important difference from control beagles not given radionuclides, even at group mean cumulative skeletal radiation doses up to 101 Gy. Because of a large proportion of dogs with fractures that died with bone malignancy (even at dosage levels lower than those exhibiting an excess average number of fractures per dog), they conclude that fracture would not be an important endpoint at lower levels of plutonium contamination in humans such as would be expected to occur from occupational or environmental exposure.

  12. Radionuclide 252Cf neutron source

    International Nuclear Information System (INIS)

    Kolevatov, Yu.I.; Trykov, L.A.

    1979-01-01

    Characteristics of radionuclide neutron sourses of 252 Cf base with the activity from 10 6 to 10 9 n/s have been investigated. Energetic distributions of neutrons and gamma-radiation have been presented. The results obtained have been compared with other data available. The hardness parameter of the neutron spectrum for the energy range from 3 to 15 MeV is 1.4 +- 0.02 MeV

  13. Radionuclide diagnosis of Meckel's diverticulum

    International Nuclear Information System (INIS)

    Conway, J.J.; Northwestern Univ., Chicago, IL

    1980-01-01

    Meckel's diverticulum can be detected with a high degree of accuracy by radionuclide scintigraphy using technetium-99m pertechnetate. The technique is without risk and should precede roentgenographic studies when the diagnosis is suspected. The method is described and the causes for false positive and false negative examinations are discussed. False negatives are rare and false positives are usually secondary to other surgical entities. Overall accuracy is 85 to 90%. (orig.) [de

  14. Radionuclides for therapy: a review

    International Nuclear Information System (INIS)

    Roesler, H.; Noelpp, U.; Triller, K.J.; Steffen, R.

    1986-01-01

    Progress in angiographic techniques has been a gradual evolutionary development which now permits the selective and superselective access to a tumor's vascular bed. A diagnostic angiographic procedure can be supplemented by a one-step, quick application of embolizing radioactive material. This endoarterial radionuclide embolizing tumor therapy has the maximum selectivity among radiotherapeutic methods, with the highest radiation doses to the tumor and neglectible exposure of normal tissue. Spread of radioactivity by diffusion or leaching can be prevented

  15. Radionuclide dispersion in the atmosphere

    International Nuclear Information System (INIS)

    Moura Neto, C. de; Amorim, E.S. do; Panetta, J.

    1979-05-01

    The instantaneous liberation of radionuclides in the atmosphere is studied in three dimensions, according to the formalism of the diffusion theory. The analytical solution, expose to gravitational and an atmospherical effects, is combined with the discretization of space and time in the calculation of levels of exposure. A typical inventory (for a PWR) was considered in the calculation of immersion doses, and the results permitted a comparative analysis among the different existing models. (Author) [pt

  16. Radiation protection in radionuclide investigations

    International Nuclear Information System (INIS)

    Taylor, D.M.

    1985-01-01

    The subject is covered in sections: introduction; radiation and radioactivity; alpha particles; beta particles; neutrons; electromagnetic radiation; units of radioactivity and radiation; biological effects of radiation; the philosophy of radiation protection (ALARA principle); practical aspects of radiation protection; work with unsealed radiation sources; radionuclide studies in experimental animals; radiation safety during clinical investigations; legislative control of radiation work; radioactive waste disposal; emergency procedures; conclusion. (U.K.)

  17. Radionuclide evaluation of renal transplants

    International Nuclear Information System (INIS)

    Yang Hong; Zhao Deshan

    2000-01-01

    Radionuclide renal imaging and plasma clearance methods can quickly quantitate renal blood flow and function in renal transplants. They can diagnose acute tubular necrosis and rejection, renal scar, surgical complications such as urine leaks, obstruction and renal artery stenosis after renal transplants. At the same time they can assess the therapy effect of renal transplant complications and can also predict renal transplant survival from early post-operative function studies

  18. Radionuclide behavior in the environment

    International Nuclear Information System (INIS)

    Tveten, U.

    1991-09-01

    The purpose of this report is to document the results of the following task: Review for quality and consistency the available data on measurements of initial ground contamination of Chernobyl radionuclides in various parts of Norway and subsequent concentrations of these radionuclides in various environmental media as functions of time. Utilize the data obtained to verify the existing models, or to improve them, for describing radionuclide behavior in the environment. Some of the processes standard were: migration into soil; weathering; resuspension; food-chain contamination; and loss or reconcentration by run-off. The task performed within this contract has been to use post-Chernobyl data from Norway to verify or find areas for possible improvement in the chronic exposure pathway models utilized in MACCS. Work has consisted mainly of collecting and evaluating post-Chernobyl information from Norway or other countries when relevant; but has also included experimental work performed specifically for the current task. In most connections the data available show the models and data in MACCS to be appropriate. A few areas where the data indicate that the MACCS approach is faulty or inadequate are, however, pointed out in the report. These should be examined carefully, and appropriate modifications should eventually be made. 14 refs., 12 figs., 22 tabs

  19. Table of Radionuclides (Vol. 7 - A = 14 to 245) - Monograph BIPM-5

    International Nuclear Information System (INIS)

    Arinc, Arzu; Be, Marie-Martine; Chiste, Vanessa; Mougeot, Xavier; Chechev, Valery P.; Galan, Monica; Huang, Xialong; Kondev, Filip G.; Luca, Aurelian; Nichols, Alan L.

    2013-02-01

    This monograph is one of several published in a series by the Bureau International des Poids et Mesures (BIPM) on behalf of the Consultative Committee for Ionizing Radiation (Comite Consultatif des Rayonnements Ionisants, CCRI). The aim of this series of publications is to review topics that are of importance for the measurement of ionizing radiation and especially of radioactivity, in particular those techniques normally used by participants in international comparisons. The purpose of this monograph, number 5 in the series, is to present the recommended values of nuclear and decay data for a wide range of radionuclides. Activity measurements for more than sixty-three of these radionuclides have already been the subject of comparisons under the auspices of Section II (dedicated to the Measurement of radionuclides) of the CCRI. The material for this monograph is now covered in seven volumes. The first two volumes contain the primary recommended data relating to half-lives, decay modes, x-rays, gamma-rays, electron emissions; alpha- and beta-particle transitions and emissions, and their uncertainties for a set of sixty-eight radionuclides, Volume 1 for those radionuclides with mass number up to and including 150 and Volume 2 for those radionuclides with mass number over 150. Volume 3 contains the equivalent data for twenty-six additional radionuclides as listed and re-evaluations for 125 Sb and 153 Sm. Volume 4 contains the data for a further thirty-one radionuclides with a re-evaluation for 226 Ra and Volume 5 includes seventeen new radionuclide evaluations and eight re-evaluations of previous data as identified in the contents page. Volume 6 contains twenty-one new radionuclide evaluations and four re-evaluations, for 64 Cu, 236 Np, 37 Np and 239 U. The present Volume 7 contains twenty-four new radionuclide evaluations and five re-evaluations, for 67 Ga, 208 Tl, 228 Th, 242 Cm and 244 Cm. The data have been collated and evaluated by an international working group

  20. Radionuclides and heavy metal contents in phosphogypsum samples in comparison to cerrado soils Conteúdo de radionuclídeos e metais pesados em amostras de fosfogesso, comparativamente ao de solos de cerrado

    Directory of Open Access Journals (Sweden)

    Vanusa Maria Feliciano Jacomino

    2009-10-01

    Full Text Available Phosphogysum (PG or agricultural gypsum, a solid waste from the phosphate fertilizer industry, is used as soil amendment, especially on soils in the Cerrado region, in Brazil. This material may however contain natural radionuclides and metals which can be transferred to soils, plants and water sources. This paper presents and discusses the results of physical and chemical analyses that characterized samples of PG and compares them to the results found in two typical soils of the Cerrado, a clayey and sandy one. These analyses included: solid waste classification, evaluation of organic matter content and of P, K, Ca, Mg, and Al concentrations and of the mineralogical composition. Natural radionuclides and metal concentrations in PG and soil samples were also measured. Phosphogypsum was classified as Class II A - Not Dangerous, Not Inert, Not Corrosive and Not Reactive. The organic matter content in the soil samples was low and potential acidity high. In the mean, the specific 226Ra activity in the phosphogypsum samples (252 Bq kg-1 was below the maximum level recommended by USEPA, which is 370 Bq kg-1 for agricultural use. In addition, this study verified that natural radionuclides and metals concentrations in PG were lower than in the clayey Oxisol of Sete Lagoas, Minas Gerais, Brazil. These results indicated that the application of phosphogypsum as soil amendment in agriculture would not cause a significant impact on the environment.O fosfogesso ou "gesso agrícola" - um resíduo sólido da indústria de produção de fertilizantes fosfatados - é usado como condicionador de solos, em especial do solo da região do Cerrado, Brasil. Entretanto, esse material contém radionuclídeos naturais e metais que podem ser transferidos para o solo, as plantas e o lençol freático. Neste trabalho são apresentados e discutidos os resultados de análises químicas e físicas para caracterização do fosfogesso e compara seus resultados com aqueles

  1. Radionuclide daughter inventory generator code: DIG

    International Nuclear Information System (INIS)

    Fields, D.E.; Sharp, R.D.

    1985-09-01

    The Daughter Inventory Generator (DIG) code accepts a tabulation of radionuclide initially present in a waste stream, specified as amounts present either by mass or by activity, and produces a tabulation of radionuclides present after a user-specified elapsed time. This resultant radionuclide inventory characterizes wastes that have undergone daughter ingrowth during subsequent processes, such as leaching and transport, and includes daughter radionuclides that should be considered in these subsequent processes or for inclusion in a pollutant source term. Output of the DIG code also summarizes radionuclide decay constants. The DIG code was developed specifically to assist the user of the PRESTO-II methodology and code in preparing data sets and accounting for possible daughter ingrowth in wastes buried in shallow-land disposal areas. The DIG code is also useful in preparing data sets for the PRESTO-EPA code. Daughter ingrowth in buried radionuclides and in radionuclides that have been leached from the wastes and are undergoing hydrologic transport are considered, and the quantities of daughter radionuclide are calculated. Radionuclide decay constants generated by DIG and included in the DIG output are required in the PRESTO-II code input data set. The DIG accesses some subroutines written for use with the CRRIS system and accesses files containing radionuclide data compiled by D.C. Kocher. 11 refs

  2. Radionuclide migration test using undisturbed aerated soil

    International Nuclear Information System (INIS)

    Yamamoto, Tadatoshi; Ohtsuka, Yoshiro; Ogawa, Hiromichi; Wadachi, Yoshiki

    1988-01-01

    As one of the most important part of safety assessment on the shallow land disposal of lowlevel radioactive waste, the radionuclide migration was studied using undisturbed soil samples, in order to evaluate an exact radionuclide migration in an aerated soil layer. Soil samples used in the migration test were coastal sand and loamy soil which form typical surface soil layers in Japan. The aqueous solution containing 60 CoCl 2 , 85 SrCl 2 and 137 CsCl was fed into the soil column and concentration of each radionuclide both in effluent and in soil was measured. Large amount of radionuclides was adsorbed on the surface of soil column and small amount of radionuclides moved deep into the soil column. Difference in the radionuclide profile was observed in the low concentration portion particularly. It is that some fractions of 60 Co and 137 Cs are stable in non-ionic form and move downward through the soil column together with water. The radionuclide distribution in the surface of soil column can be fairly predicted with a conventional migration equation for ionic radionuclides. As a result of radionuclide adsorption, both aerated soil layers of coastal sand and loamy soil have large barrier ability on the radionuclide migration through the ground. (author)

  3. Metabolism of radionuclides in domestic animals

    International Nuclear Information System (INIS)

    Wirth, E.; Leising, C.

    1986-01-01

    The reactor accident at Chernobyl has shown that shortly after the contamination of the environment radionuclides can be found in animal products. The main contamination pathways of domestic animas are: uptake of radionuclides by foodstuffs; uptake of radionuclides by contaminated drinking water; uptake of radionuclides by inhalation; uptake of radionuclides through skin; uptake of radionuclides by ingestion of soil particles. Generally the uptake of radionuclides by food is the dominant exposure pathway. In rare cases the inhalation of radionuclides or the uptake by drinking water may be of importance. The metabolism of incorporated radionuclides is comparable to the respective metabolism of essential mass or trace elements or heavy metals. Radioisotopes of essential elements are for instance iron 55, manganese 54, cobalt 58 and cobalt 60. Other elements are typical antagonists to essential elements, e.g. strontium 90 is an antagonist to calcium or cesium 137 to potassium. Lead 210 and plutonium 239 behave similarly as heavy metals. Generally the knowledge of the metabolism of trace and mass elements, of antagonistic and synergistic elements and heavy metals can be applied to these radionuclides

  4. Liquid discharges from the use of radionuclides in medicine (diagnosis)

    International Nuclear Information System (INIS)

    Barquero, R.; Agulla, M.M.; Ruiz, A.

    2008-01-01

    The production and discharge of liquid radioactive wastes as excreta from patients undergoing Nuclear Medicine Diagnostic (NMD) in a hospital were studied. Instantaneous and accumulated activity, discharged from the hospital to the sewage system, has been estimated keeping in mind radionuclide decay. This study would enable estimation of the environmental impact due to NMD procedures. Annual accumulated activities of 2.2 GBq ( 131 I), 1.847 GBq ( 99m Tc), 0.743 GBq ( 123 I), 0.337 GBq ( 67 Ga), 0.169 GBq ( 111 In) and 0.033 GBq ( 201 Tl) result from our model when applied to a European hospital. A comparison is made with calculations by other authors that do not consider the radionuclide decay and who overestimate by two orders of magnitude. Doses to critical people as sewage treatment workers are also significantly reduced. So, our results stress the importance of including the decay in the calculations

  5. Laboratory studies of radionuclide transport in fractured Climax granite

    International Nuclear Information System (INIS)

    Failor, R.; Isherwood, D.; Raber, E.; Vandergraaf, T.

    1982-06-01

    This report documents our laboratory studies of radionuclide transport in fractured granite cores. To simulate natural conditions, our laboratory studies used naturally fractured cores and natural ground water from the Climax Granite Stock at the Nevada Test Site. For comparison, additional tests used artificially fractured granite cores or distilled water. Relative to the flow of tritiated water, 85 Sr and /sup 95m/Tc showed little or no retardation, whereas 137 Cs was retarded. After the transport runs the cores retained varying amounts of the injected radionuclides along the fracture. Autoradiography revealed some correlation between sorption and the fracture fill material. Strontium and cesium retention increased when the change was made from natural ground water to distilled water. Artificial fractures retained less 137 Cs than most natural fractures. Estimated fracture apertures from 18 to 60 μm and hydraulic conductivities from 1.7 to 26 x 10 -3 m/s were calculated from the core measurements

  6. Effectiveness of direct and indirect radionuclide cystography in detecting vesicoureteral reflux

    International Nuclear Information System (INIS)

    Conway, J.J.; Kruglik, G.D.

    1976-01-01

    A modified of the direct radionuclide cystography technique to include filling, voiding, and postvoiding phases of the examination permitted a simulated comparison between direct and indirect radionuclide cystography. One hundred thirty-seven examples of reflux were documented with this technique. Of these, 96 instances of reflux (70 percent) were recorded during two or more phases and thus would have been detected by either technique. Twenty-nine examples (21 percent) were only detected during filling and thus would have been missed by the indirect radionuclide technique and by some roentgenographic techniques. Only 12 examples (9 percent) were detected during the voiding phase only. The modified direct method of radionuclide cystography, which continuously monitors the urinary tracts during filling, voiding, and postvoiding, is offered as the best current technique for assessing visicoureteral reflus

  7. Evaluation of obstructive uropathy in children: radionuclide renography vs. the Whitaker test

    International Nuclear Information System (INIS)

    Senac, M.O. Jr.; Miller, J.H.; Stanley, P.

    1984-01-01

    Differentiation of obstructed from dilated, nonobstructed urinary systems in the postoperative child is a difficult diagnostic problem. A comparison study was performed in 21 children with hydroureteronephrosis using the Whitaker test in combination with conventional radionuclide renography and/or diuretic (furosemide)-augmented radionuclide renography. The results of each method were corelated with the clinical assessment and surgical findings. Conventional renography was found to be an unreliable study, with a clinical correctness of only 57%. Results were more favorable for both the Whitaker test and diurectic-augmented radionuclide renography, with clinical correctness in 86% and 85%, respectively. Due to the noninvasive nature of the study, diuretic-augmented radionuclide renography should be the initial procedure once hydroureteronephrosis is established. A recommended algorithm of the child with postoperative hydroureteronephrosis is suggested

  8. Natural radionuclides in an eucalyptus forest located in the south of Spain

    International Nuclear Information System (INIS)

    Vaca, F.; Manjon, G.; Garcia-Leon, M.

    2001-01-01

    Eucalyptus forests can be considered as the main source of raw material for the pulp industry of Spain. This environment was selected for a radioactivity study because natural and artificial radionuclides can be transferred into the pulp mills, associated with raw material, wood and barks, where they are concentrated by industrial processes, becoming a cause of doses. Radionuclide concentration of natural radionuclides ( 238 U, 234 U, 228 Th, 230 Th, 232 Th) were determined by alpha- and gamma-spectrometry. Well-established radiochemical procedures were applied to environmental samples in order to isolate these radionuclides. A comparison between 228 Th activity, determined by gamma-spectrometry, and 232 Th activity, determined by alpha-spectrometry, was used as quality control parameter for analyses. The concentration factors were finally evaluated from experimental data.

  9. Methods of separating short half-life radionuclides from a mixture of radionuclides

    Science.gov (United States)

    Bray, Lane A.; Ryan, Jack L.

    1998-01-01

    The present invention is a method of obtaining a radionuclide product selected from the group consisting of .sup.223 Ra and .sup.225 Ac, from a radionuclide "cow" of .sup.227 Ac or .sup.229 Th respectively. The method comprises the steps of a) permitting ingrowth of at least one radionuclide daughter from said radionuclide "cow" forming an ingrown mixture; b) insuring that the ingrown mixture is a nitric acid ingrown mixture; c) passing the nitric acid ingrown mixture through a first nitrate form ion exchange column which permits separating the "cow" from at least one radionuclide daughter; d) insuring that the at least one radionuclide daughter contains the radionuclide product; e) passing the at least one radionuclide daughter through a second ion exchange column and separating the at least one radionuclide daughter from the radionuclide product and f) recycling the at least one radionuclide daughter by adding it to the "cow". In one embodiment the radionuclide "cow" is the .sup.227 Ac, the at least one daughter radionuclide is a .sup.227 Th and the product radionuclide is the .sup.223 Ra and the first nitrate form ion exchange column passes the .sup.227 Ac and retains the .sup.227 Th. In another embodiment the radionuclide "cow"is the .sup.229 Th, the at least one daughter radionuclide is a .sup.225 Ra and said product radionuclide is the .sup.225 Ac and the .sup.225 Ac and nitrate form ion exchange column retains the .sup.229 Th and passes the .sup.225 Ra/Ac.

  10. Comparison between MAAP and ECART predictions of radionuclide transport throughout a French standard PWR reactor coolant system; Transport des radionucleides dans le circuit primaire d`un REP: comparaison des codes MAAP et ECART

    Energy Technology Data Exchange (ETDEWEB)

    Hervouet, C.; Ranval, W. [Electricite de France (EDF), 92 - Clamart (France); Parozzi, F.; Eusebi, M. [Ente Nazionale per l`Energia Elettrica, Rome (Italy)

    1996-04-01

    In the framework of a collaboration agreement between EDF and ENEL, the MAAP (Modular Accident Analysis Program) and ECART (ENEL Code for Analysis of radionuclide Transport) predictions about the fission product retention inside the reactor cooling system of a French PWR 1300 MW during a small Loss of Coolant Accident were compared. The volatile fission products CsI, CsOH, TeO{sub 2} and the structural materials, all of them released early by the core, are more retained in MAAP than in ECART. On the other hand, the non-volatile fission products, released later, are more retained in ECART than in MAAP, because MAAP does not take into account diffusion-phoresis: in fact, this deposition phenomenon is very significant when the molten core vaporizes the water of the vessel lower plenum. Centrifugal deposition in bends, that can be modeled only with ECART, slightly increases the whole retention in the circuit if it is accounted for. (authors). 18 refs., figs., tabs.

  11. Effect of Peptide Receptor Radionuclide Therapy on Somatostatin Receptor Status and Glucose Metabolism in Neuroendocrine Tumors: Intraindividual Comparison of Ga-68 DOTANOC PET/CT and F-18 FDG PET/CT

    Science.gov (United States)

    Oh, Sowon; Prasad, Vikas; Lee, Dong Soo; Baum, R. P.

    2011-01-01

    The heterogeneous nature of the neuroendocrine tumors (NET) makes it challenging to find one uniformly applicable management protocol which is especially true for diagnosis. The discovery of the overexpression of somatostatin receptors (SMS-R) on neuroendocrine tumor cells lead to the generalized and rapid acceptance of radiolabeled somatostatin receptor analogs for staging and restaging of NET as well as for Peptide Receptor Radionuclide Therapy (PRRNT) using Y-90 and Lu-177 DOTATATE/DOTATOC. In this present work we tried to look in to the effect of PRRNT on the glucose metabolism assessed by F-18 FDG PET/CT and SMS-R density assessed by Ga-68 DOTANOC PET/CT. We observed a complex relationship between the somatostatin receptor expression and glucose metabolism with only 56% (77/138) of the lesions showing match, while the others show mismatch between the receptor status and metabolism. The match between receptor expression and glucose metabolism increases with the grade of NET. In grade 3 NET, there is a concurrence between the changes in glucose metabolism and somatostatin receptor expression. PRRNT was found to be more effective in lesions with higher receptor expression. PMID:22121482

  12. Phytoremediation of radionuclides: an emerging alternative

    International Nuclear Information System (INIS)

    Singh, Shraddha

    2013-01-01

    Proliferation of nuclear power industry, nuclear weapon testing, dismantling of existing nuclear weapons and occasional accidents have contributed to an enhancement in the level of radionuclides in the environment. The radionuclides due to their long half life and transfer through the food chain effect adversely to normal biological systems. Hence, it is essential to effectively remove the radionuclides from contaminated soils and solutions. Phytoremediation - the use of plants for remediation of toxic metals and radionuclides has been recognized as an aesthetically pleasing, low cost and environment friendly in situ method. Phytoremediation is an umbrella term which covers several plant based approaches. Plants have shown the potential of remediation of these radionuclides from spiked solutions, low level nuclear waste and soil. Various aspects of phytoremediation as well as potential of various plants for remediation of radionuclides will be discussed here. (author)

  13. Radionuclide transport processes in terrestrial ecosystems

    International Nuclear Information System (INIS)

    Whicker, F.W.

    1983-01-01

    Some major principles and the status of knowledge concerning the transport of radionuclides through terrestrial ecosystems are reviewed. Fundamental processes which control the flow of radionuclides between ecosystem components such as air, soil, plants, and animals are described, with emphasis on deposition, resuspension, plant uptake, ingestion, and assimilation. Properties of radionuclides, organisms, and ecosystems are examined in relation to their influence on the accumulation of radioactive materials by plants and animals. The effects of the physicochemical nature of the radionuclide; morphology, physiology, and behavior of the organism; and soil, nutrient, and trophic characteristics of the ecosystem are highlighted. Observations in natural ecosystems on radionuclides such as 137 Cs, 90 Sr, 131 I, 3 H, and 239 Pu are used to illustrate current concepts. An assessment of the degree to which the processes controlling radionuclide behavior are understood and of our ability to simulate and predict such behavior with computerized models is offered. Finally, brief comments are made on research needs

  14. Radionuclides in the study of marine processes

    International Nuclear Information System (INIS)

    Kershaw, P.J.; Woodhead, D.S.

    1991-01-01

    For many years, the radioactive properties of the naturally occurring radionuclides have been used to determine their distributions in the marine environment and, more generally, to gain an understanding of the dynamic processes which control their behaviour in attaining these distributions. More recently the inputs from human activities of both natural and artificial (i.e. man-made) radionuclides have provided additional opportunities for the study of marine processes on local, regional and global scales. The primary objective of the symposium is to provide a forum for an open discussion of the insights concerning processes in the marine environment which can be gained from studies of radionuclide behaviour. Papers have been grouped within the following principal themes; the uses of radionuclides as tracers of water transport; scavenging and particulate transport processes in the oceans as deduced from radionuclide behaviour; processes in the seabed and radionuclides in biological systems. (Author)

  15. Chemical speciation of radionuclides migrating in groundwaters

    International Nuclear Information System (INIS)

    Robertson, D.; Schilk, A.; Abel, K.; Lepel, E.; Thomas, C.; Pratt, S.; Cooper, E.; Hartwig, P.; Killey, R.

    1994-04-01

    In order to more accurately predict the rates and mechanisms of radionuclide migration from low-level waste disposal facilities via groundwater transport, ongoing studies are being conducted at field sites at Chalk River Laboratories to identify and characterize the chemical speciation of mobile, long-lived radionuclides migrating in groundwaters. Large-volume water sampling techniques are being utilized to separate and concentrate radionuclides into particular, cationic, anionic, and nonionic chemical forms. Most radionuclides are migrating as soluble, anionic species that appear to be predominantly organoradionuclide complexes. Laboratory studies utilizing anion exchange chromatography have separated several anionically complexed radionuclides, e.g., 60 Co and 106 Ru, into a number of specific compounds or groups of compounds. Further identification of the anionic organoradionuclide complexes is planned utilizing high resolution mass spectrometry. Large-volume ultra-filtration experiments are characterizing the particulate forms of radionuclides being transported in these groundwaters

  16. Production of radionuclides with generators

    International Nuclear Information System (INIS)

    Khujaev, S.; Egamediev, S.Kh.

    2004-01-01

    Full text: The radionuclide generator provides a convenient means for researchers and clinicians to obtain a source of radionuclides without dependence on nuclear facilities (nuclear reactor or cyclotron). It should be noted that radionuclide generator technique yields products of very high purity and it offers moreover the only possible way of obtaining very short-lived radionuclides for practical applications. Therefore at present radionuclide generators have found important uses in nuclear medicine. This talk reviews the development of preparation methods for radionuclide generators of current interest: 99 Mo- 99m Tc, 188 W- 188 Re and 68 Ge- 68 Ga. 99 Mo- 99m Tc generator. 99m Tc is presently the most widely used radionuclide in diagnostic nuclear medicine. The reason for such a preeminent position of 99m Tc in clinical uses is its extremely favorable nuclear properties with γ-energy of 140 keV and short half-life of 6 hours. Chromatographic generator of 99 Mo- 99m Tc based on aluminium oxide using as eluent of isotonic saline solution, containing nitrate-ions has been produced in INP AS RU. However, the main disadvantage of this generator is that the eluent-saline solution contains some amount of nitrate-ions. Nitrate-ions added to maximize and stabilize 99m Tc yields would interfere with the chemical reactions which involve Sn(II) reduction of the pertechnetate ion and which are used subsequently in the preparation of radiopharmaceuticals. Therefore we proposed the new method for preliminary treatment of aluminium oxide by the external gamma (Co-60) irradiation. It is found that the aluminium oxide has got electron-acceptor properties after gamma-irradiation. Adsorption of 99 Mo radionuclide as isopolymolybdate on gamma-irradiated aluminium oxide is very high and molybdenum is firmly retained. Adsorption capacity of gamma-irradiated aluminium oxide at pH 2-4 is 60-80 mg Mo per gram of Al 2 O 3 . The yields of 99m Tc from experimental generators remained high

  17. Performance and quality control of radionuclide calibrators in nuclear medicine

    International Nuclear Information System (INIS)

    Woods, M.J.; Baker, M.

    2002-01-01

    operators can be determined by the conduct of comparison exercises by expert and impartial laboratories. Such exercises can also have the added advantage of enabling the calibration of particular calibrators to be checked and even determined more accurately. A regular programme of such comparisons has been organised in the United Kingdom by the National Physical Laboratory (NPL) over the last fifteen to twenty years and follow-up workshops have been held for the participants to discuss the results and the potential avenues to performance improvements. The outputs from these comparisons, supplemented by regular dialogues and exchanges of information and experiences between the NPL and the user community, have identified a number of potential sources of error. In addition, the NPL, together with the relevant professional organisation in the UK, produced a quality assurance protocol in 1992, designed to establish and maintain the calibration of medical radionuclide calibrators and their quality control. That protocol is currently being revised to take into account both the increased emphasis on uncertainty estimation, the accumulation of comparison data and user experiences and the changes in equipment formats. This paper presents and discusses the results of the various comparisons conducted by NPL, particularly as they relate to the potential improvements in performance that can be achieved, and the developments in the recommended quality assurance protocol. It also addresses the developments of calibration facilities available with these systems, especially as they relate to the measurement of, and achievable accuracies for, therapeutic radiation sources. (author)

  18. DKPRO: A radionuclide decay and reprocessing code

    International Nuclear Information System (INIS)

    Wootan, D.; Schmittroth, F.A.

    1997-01-01

    The DKPRO code solves the general problem of modeling complex nuclear wastes streams using ORIGEN2 radionuclide production files. There is a continuing need for estimates of Hanford radionuclides. Physical measurements are one basis; calculational estimates, the approach represented here, are another. Given a known nuclear fuel history, it is relatively straightforward to calculate radionuclide inventories with codes such as the widely-used Oak Ridge National Laboratory code ORIGEN2

  19. Radionuclide usage survey 1979-80

    International Nuclear Information System (INIS)

    Woods, M.J.

    1980-08-01

    Details of a survey by the Life Sciences Working Group of the International Committee for Radionuclide Metrology (ICRM) on radionuclide usage by medical physicists in 11 countries are presented. The results indicate that the radionuclide which will be of most significance in the future will be F-18, Fe-52, Ga-67, Ga-68, Kr-81m, Tc-99m, In-111, I-123, Xe-127 and Tl-201, (U.K.)

  20. Preparation of porous materials for radionuclides capture

    International Nuclear Information System (INIS)

    Bajzikova, Anna; Smrcek, Stanislav; Kozempel, Jan; Vlk, Martin; Barta, Jan

    2015-01-01

    Porous materials showing promise for radionuclide capture from water at contaminated sites were prepared. Nanoporous materials (size of pores 1-100 nm) and some polymers are well suited to this purpose owing their affinity for selected radionuclides. Nanoporous metal oxides and silica gel with styrene-divinylbenzene-TODGA-modified surface were prepared, characterized and tested for radionuclide ( 227 Ac, 227 Th, 223 Ra) capture efficiency. (orig.)

  1. Environmental behaviour of radionuclides and transfer to man

    International Nuclear Information System (INIS)

    Smith, H.

    1982-01-01

    The environmental behaviour of the radionuclides making the major contribution to man's irradiation through diet is described. The following stages are emphasized: transfer of radionuclides to plants; transfer of radionuclides to animals; metabolism of inhaled or ingested radionuclides in animals providing food for man; transfer of radionuclides through the aquatic environment; application of food chain models. (43 references)

  2. Update of the ongoing comparison BIPM.RI(II)-K1.Se-75 to include recent activity measurements of the radionuclide {sup 75}Se by the LNE-LNHB (France)

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Courte, S.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), Pavillon de Breteuil, F-92312 Sevres cedex (France); Moune, M.; Bobin, C. [Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel (LNE-LNHB), Gif-sur-Yvette Cedex (France)

    2011-06-15

    In 2006, to update their previous result of 1992, the LNE-LNHB submitted a new sample of {sup 75}Se with an activity of about 2.2 MBq to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures (BIPM). This comparison has the identifier BIPM.RI(II)-K1.Se-75. The degree of equivalence between the equivalent activity measured in the SIR for the new LNE-LNHB sample and the updated key comparison reference value (KCRV) has been calculated, as have the degrees of equivalence with each of the other participants. The results are given in the form of a matrix and a graphical presentation is also given. (authors)

  3. Activity measurements of the radionuclide {sup 57}Co for the NMIJ, Japan and the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.Co-57

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Ratel, G.; Courte, S. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Hino, Y.; Yunoki, A. [National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki (Japan); Bobin, C.; Moune, M. [CEA Saclay, Laboratoire National de Metrologie et d' Essais, Laboratoire National Henri Becquerel (LNE-LNHB), 91 - Gif-sur-Yvette (France)

    2009-04-15

    In 2006 and 2007, the National Metrology Institute of Japan (NMIJ) and the Laboratoire national de metrologie et d'essais-Laboratoire national Henri Becquerel (LNE-LNHB) submitted samples of known activity of {sup 57}Co to the International Reference System (SIR). The values of the activity submitted were about 1.7 MBq and 3.7 MBq respectively. The new key comparison results have replaced the previous results for Japan and France. These new results have enabled a re-evaluation of the key comparison reference value. The matrix of degrees of equivalence in the key comparison database that now contains twelve results, identifier BIPM.RI(II)-K1.Co-57, has been updated with the new results. (authors)

  4. Radionuclide accumulation peculiarities demonstrated by vegetable varieties

    International Nuclear Information System (INIS)

    Kruk, A.V.; Goncharenko, G.G.; Kilchevsky, A.V.

    2004-01-01

    This study focused on ecological and genetic aspects of radionuclide accumulation demonstrated by a number of vegetable varieties. The researches resulted in determining the cabbage varieties which were characterised by the minimal level of radionuclide accumulation. It was shown that the above varieties manifested the relation between radionuclide accumulation and morphobiological characteristics such as vegetation period duration and yield criteria. The study specified the genotypes with high ecological stability as regards to radionuclide accumulation: 'Beloruskaya 85' cabbage and 'Dokhodny' tomato showed the best response to Cs 137, while 'Beloruskaya 85', 'Rusinovka', 'Amager 611' cabbage varieties and 'Sprint' tomato showed the minimal level of Sr 90 accumulation. (authors)

  5. Therapy for incorporated radionuclides: scope and need

    International Nuclear Information System (INIS)

    Smith, V.H.

    1981-03-01

    In the United States the recent termination of funding for research on therapy for incorporated radionuclides has virtually halted progress on improved or new agents and procedures for removing radioactivity from the body. Research was eliminated, but is still needed on new removal agents, improved delivery system, in vitro test systems, and the toxicology of treatments. For many radionuclides, no adequate therapy exists. The relationship between radionuclide removal and reduction in cancer risk is still unanswered. Without proper research support, needed improvements in the treatment for incorporated radionuclides in the US are uncertain

  6. Radionuclide transport through heteogeneous media

    International Nuclear Information System (INIS)

    Hadermann, J.

    1980-01-01

    One-dimensional radionuclide migration for conevective water transport with sorption and longitudinal dispersion is investigated. A semianalytic solution for layered media with piecewise constant parametes can be written when taking into account mass conservation and approximate flux conservation at interlayer boundaries. The solution is analytic in the first layer and allows for a recursive calculation in the following layers. Scaling laws for the relevant parameters can be formulated. Numerical examples exhibit the importance of at least a single highly sorbing layer. Small values of dispersivity may not lead to a conservative estimate of conservation at the geological column's end

  7. Radionuclide transfer to meadow vegetation

    International Nuclear Information System (INIS)

    Goncharova, N.; Matsko, N.; Zhebrakova, I.; Montik, T.

    1999-01-01

    In the paper results of radioecological monitoring of natural plant populations in the 30 km zone of the Chernobyl Nuclear Power Plant (Polesky State Radioecological Reserve) during the period from 1987 to 1998 are presented. The level of radiation background in experimental areas varied from 0.1 to 30 mR/h that correspond to the total soil activity of 300-24000 kBq/m 2 (for May 1997). Monitoring was carried out including the radionuclide migration in natural plant complexes and transfer of 137 Cs between some plant organs. Refs. 3 (author)

  8. Dosimetry of incorporated transuranic radionuclides

    International Nuclear Information System (INIS)

    Loessner, V.

    1983-01-01

    Modern in vivo and in vitro techniques for detecting transuranic radionuclides within the human body are described with special emphasis on multiparameter measuring methods developed at the National Board of Nuclear Safety and Radiation Protection. Furthermore, problems related to calibration and interpretation of measuring data are discussed and new methods presented for the calculation of committed dose equivalents on the basis of data from ICRP Publication 30. Also included is an introductory chapter on radiobiological fundamentals of intake, translocation and metabolism of these nuclides. (author)

  9. Dietary intake of natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Briggs, J L; Bradley, E J [National Radiological Protection Board, Chilton (UK)

    1984-09-01

    The levels of the natural radionuclides, radium-226, lead-210 and polonium-210 were measured in food samples collected for a National Food Survey, thus reflecting current consumption patterns in the UK. Daily intakes of radium-226, lead-210 and inferred values of polonium-210 were calculated for 20 food groups. From these data, the annual effective dose equivalents from radium-226, lead-210 and polonium-210 in the UK diet were estimated to be 3..mu..Sv, 41..mu..Sv and 13..mu..Sv respectively.

  10. Dietary intake of natural radionuclides

    International Nuclear Information System (INIS)

    Smith-Briggs, J.L.; Bradley, E.J.

    1984-01-01

    The levels of the natural radionuclides, radium-226, lead-210 and polonium-210 were measured in food samples collected for a National Food Survey, thus reflecting current consumption patterns in the UK. Daily intakes of radium-226, lead-210 and inferred values of polonium-210 were calculated for 20 food groups. From these data, the annual effective dose equivalents from radium-226, lead-210 and polonium-210 in the UK diet were estimated to be 3μSv, 41μSv and 13μSv respectively. (U.K.)

  11. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Park, Hyun Soo

    2003-04-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. This project is composed of 6 subjects such as data production required for safety assessments, sorption properties and mechanisms, nuclide migration in the fractured rock, colloid formation and migration, nuclide speciation in deep geological environments, and total evaluation of geochemical behaviors considering multi-factors. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  12. Miscellaneous applications of radionuclide imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.; Freeman, L.M.

    1984-01-01

    The procedures discussed in this chapter are either developmental, in limited clinical use, or frankly moribund. A number of radionuclide imaging techniques have proved disappointing when approached from a purely anatomic point of view. This is particularly evident to our colleagues with the explosive growth of the noninvasive imaging procedures, magnetic resonance imaging (NMR), CT, and ultrasound, and the introduction of the less invasive digital radiographic approach to vascular opacification, all of which are capable of providing exquisite anatomic or tissue detail beyond the reach of current or reasonably priced nuclear medicine imaging systems. Yet, most nuclear medicine procedures possess the unique advantage of portraying a physiologic function without interfering with that function. Moreover, the procedures can be employed under conditions of stress, which are likely to bring out pathophysiologic abnormalities that remain masked when unchallenged. Information concerning form without functional data has less meaning than both together. The physiologic information inherent in nuclear medicine imaging may often provide not only key diagnostic information but also illuminate a therapeutic trail. Yet, it is often slighted in favor of the anatomic quest. While mastery of the nuances of imaging details remains critical, radionuclide image interpretation must rest upon a firm physiologic foundation. For this reason, this chapter emphasizes the physiologic approach

  13. Stochastic approach for radionuclides quantification

    Science.gov (United States)

    Clement, A.; Saurel, N.; Perrin, G.

    2018-01-01

    Gamma spectrometry is a passive non-destructive assay used to quantify radionuclides present in more or less complex objects. Basic methods using empirical calibration with a standard in order to quantify the activity of nuclear materials by determining the calibration coefficient are useless on non-reproducible, complex and single nuclear objects such as waste packages. Package specifications as composition or geometry change from one package to another and involve a high variability of objects. Current quantification process uses numerical modelling of the measured scene with few available data such as geometry or composition. These data are density, material, screen, geometric shape, matrix composition, matrix and source distribution. Some of them are strongly dependent on package data knowledge and operator backgrounds. The French Commissariat à l'Energie Atomique (CEA) is developing a new methodology to quantify nuclear materials in waste packages and waste drums without operator adjustment and internal package configuration knowledge. This method suggests combining a global stochastic approach which uses, among others, surrogate models available to simulate the gamma attenuation behaviour, a Bayesian approach which considers conditional probability densities of problem inputs, and Markov Chains Monte Carlo algorithms (MCMC) which solve inverse problems, with gamma ray emission radionuclide spectrum, and outside dimensions of interest objects. The methodology is testing to quantify actinide activity in different kind of matrix, composition, and configuration of sources standard in terms of actinide masses, locations and distributions. Activity uncertainties are taken into account by this adjustment methodology.

  14. Infusion of radionuclides throughout pregnancy

    International Nuclear Information System (INIS)

    Mountford-Lister, P.G.; Lambert, B.E.; Milner, A.C.; Kang, X.Z.

    1992-01-01

    This work is part of a long-term study to examine the cancer incidence in the offspring of mice exposed to 239 Pu or 147 Pm throughout pregnancy. The need to model the human intake scenario and the possibility of a critical period during uterine development necessitates constant availability of radionuclides throughout pregnancy. Various methods (multiple daily injections, infusion by external cannula and infusion by indwelling osmotic pump) have been examined and osmotic infusion pumps chosen. These pumps result in a near-constant blood concentration for up to 21 days. Part of the study is the estimation of dose to the critical haemopoietic tissues of the pup from a knowledge of the radionuclide distribution and kinetics. At present the distribution has been followed from birth to 180 days. Activity in the suckling pups at 7 days old is around 1 percent of the infused activity, though most of this is accounted for by the contents of the stomach and gastrointestinal tract. The liver and femur account for around 0.025 percent and 0.012 percent respectively per pup. Activity increases in both liver and femur during lactation after which both concentration and activity fall with time. Long-term studies with the pups of dams exposed to a range of 239 Pu concentrations between 0-70 kBq/kg are underway. Correlation of average organ dose with tumour incidence will be determined at completion of the life-span study. (Author) 39 refs., 5 tabs., 6 figs

  15. Sedimentary Processes. Quantification Using Radionuclides

    International Nuclear Information System (INIS)

    Carroll, J.; Lerche, I.

    2003-01-01

    The advent of radionuclide methods in geochronology has revolutionized our understanding of modern sedimentary processes in aquatic systems. This book examines the principles of the method and its use as a quantitative tool in marine geology, with emphasis on the Pb-210 method. The assumptions and consequences of models and their behaviour are described providing the necessary background to assess the advantages and trade-offs involved when choosing a particular model for application. One of the purposes of this volume is to disentangle the influences of complicating factors, such as sediment flux variations, post-depositional diffusion of radionuclides, and bio-irrigation of sediments, to arrive at sediment ages and to properly assess the attendant data uncertainty. Environmental impacts of chemical, nuclear, or other waste material are of concern in a variety of areas around the world today. A number of relevant examples are included, demonstrating how dating models are useful for determining sources of contaminants and interpreting their influence on the environment. The book is set at a level so that an able student or professional should have no difficulty in following the procedures and methods developed. Each chapter includes case histories showing the strengths and weaknesses of a given procedure with respect to a data example. Included with this volume is the computer source code of a new generation of modelling tools based on inverse numerical analysis techniques. This first generation of the modelling tool is included, along with detailed instructions and examples for its use, in an appendix

  16. Radionuclide transit in esophageal varices

    International Nuclear Information System (INIS)

    Yeh, S.H.; Wang, S.J.; Wu, L.C.; Liu, R.S.; Tsai, Y.T.; Chiang, T.T.

    1985-01-01

    This study assessed esophageal motility in patients with esophageal varices by radionuclide transit studies. Data were acquired in list mode after an oral dose of 0.5 mCi Tc-99m sulfur colloid in 10 ml of water in the supine position above a low-energy all-purpose collimator of a gamma camera. The condensed image (CI) superimposed with a centroid curve was also produced in each case. Twenty-five normal subjects (N) and 32 patients (pts) with esophageal varices by endoscopy (large varices in Grades IV and V in 8 and small varices in Grade III or less in 24) were studied. TMTT, RTT, RF, and RI were all significantly increased in pts as compared to N. Especially, the transit time for the middle third (6.7 +- 2.6 sec vs 3.5 +- 0.9 sec in N, rho < 0.005) had the optimal sensitivy and specificity of 88% each at the cutoff value of 4.2 sec as determined by ROC analysis. In summary, radionuclide transit disorders occur in the majority of pts with esopageal varices. The middle RTT and CI are both optimal in sensitivity and specificity for detecting the abnormalities

  17. Radionuclide analysis of bush food

    International Nuclear Information System (INIS)

    Koperski, J.; Bywater, J.

    1985-01-01

    A model diet for an Aboriginal adult living entirely on bush foods collected from the Alligator Rivers Region of the Northern Territory has been established. Results of investigations of the specific activities of thorium-230, radium-226, lead-210 and polonium-210 in 123 samples of bush foods collected by Ranger Uranium Mines Pty Ltd during pre-production and production periods are presented. For all the investigated bush food items, excluding freshwater mussels (Velesunio angasi), no systematic differences were found between the specific activities of the radionuclides monitored in food items sampled during preproduction and production periods. Preliminary estimates of annual effective dose equivalent (DE) rates for stochastic effects on an adult living entirely on the model bush diet are presented. Of the four radionuclides monitored the major contributor to the effective DE rates appears to be lead-210 followed by radium-226. Among the selected nine components of the diet the major contributor to the effective DE rates appear to be mussels, water lilies and fish

  18. Radionuclide analysis of bush food

    Energy Technology Data Exchange (ETDEWEB)

    Koperski, J; Bywater, J [Ranger Uranium Mines Proprietary Ltd., Chatswood (Australia)

    1985-04-01

    A model diet for an Aboriginal adult living entirely on bush foods collected from the Alligator Rivers Region of the Northern Territory has been established. Results of investigations of the specific activities of thorium-230, radium-226, lead-210 and polonium-210 in 123 samples of bush foods collected by Ranger Uranium Mines Pty. Ltd. during pre-production and production periods are presented. For all the investigated bush food items, excluding freshwater mussels (Velesunio angasi), no systematic differences were found between the specific activities of the radionuclides monitored in food items sampled during preproduction and production periods. Preliminary estimates of annual effective dose equivalent (DE) rates for stochastic effects on an adult living entirely on the model bush diet are presented. Of the four radionuclides monitored the major contributor to the effective DE rates appears to be lead-210 followed by radium-226. Among the selected nine components of the diet the major contributor to the effective DE rates appear to be mussels, water lilies and fish.

  19. Radionuclide sorption from the safety evaluation perspective

    International Nuclear Information System (INIS)

    1992-01-01

    Research and development directed towards the assessment of the long-term performance of radioactive waste disposal systems has been recognised as a priority area with a strong need for international co-operation and co-ordination. The ultimate aims is to promote the quality and credibility of safety assessment techniques for radioactive waste disposal. Sorption in the geosphere is one of the key processes for retarding the transport of radionuclide from the underground disposal facility to the biosphere. In many cases, sorption in the near field and in the biosphere is also important. A workshop, organised to favor discussion around a small number of invited papers, was held in October 1991: - to evaluate critically the way sorption processes are incorporated in performance assessment models; - to identify open issues of high priority, and; - to propose future activities to resolve these issues. These proceedings reproduce the invited papers and the conclusions and recommendations adopted by the workshop. Eight papers are in the INIS SCOPE. The main subjects studied are: sorption database comparison, sorption database development and three case studies, experimental techniques, adsorption models

  20. Evaluation of radionuclide migration in forest ecosystems in TEMAS project

    International Nuclear Information System (INIS)

    Claver, F.; Vazquez, C.

    1998-01-01

    The applicability study of the best countermeasures for the restoration of environments contaminated by the accidental liberation of radionuclides, requires the assessment of the space and the temporal flow of radionuclides. The objective of the multinational project TEMAS (Techniques and Management Strategies for environmental restoration and their ecological consequences), that is carried out under EU-CIEMAT contract n. TI4-CT95-0021, is the development of management tool that provides the necessary support in the selection of the best strategies of environmental restoration after a nuclear accident, considering all the possible affected environments (urban, agricultural, semi natural and forest). In the forest environment,CIEMAT is working with the University of Lund (Sweden) and the Physical Science Faculty of the University of Seville in the prognosis of the distribution of Cesium and Strontium in forest ecosystems and through the associated production systems. This paper summarizes the study of the response of two different models, FORM and FORESTPATH to predict the radionuclides flow in the event of an accidental contamination of a forest. The comparison of results has been carried out over a period of 100 years after deposition on a coniferous forest. Although the approaches are different, the results obtained (using generic parameters) indicate that either model could to be selected for the analysis of the intervention in TEMAS. (Author) 14 refs

  1. The value of radionuclide cystography in the study of reflux

    International Nuclear Information System (INIS)

    Grechi, G.; Vichi, G.F.; Franchini, F.; La Cava, G.; Moretti, A.; Taddei, I.; Bartolozzi, G.

    1980-01-01

    Reduction of the risk connected with widespread and repeated radiological examinations in children is a purpose to be pursued. Children with urinary tract infection or suspected uropathy have been submitted also to radionuclide cystography (which has the advantage of a minimal radiation dose) to obtain a comparison with micturition cysto-urethrography. The authors' experience is based on 80 examinations performed in 65 children. Results obtained by the combined use of both techniques have revealed a substantial agreement in the evaluation of reflux, but also some important limitations of radionuclide cystography: the technique does not reveal the aspects of pelvis and ureter, of the uretero-vesical junction, of the bladder wall and, lastly, does not allow the study of morphology of function of cervico-uretral structures. On the basis of these limitations, radionuclide cystography can replace the micturition cysto-urethrography only in certain phases of the diagnosis and mostly of the follow-up of reflux in children; for this purpose a diagnostic protocol is proposed [fr

  2. Splenic radionuclide angiography in the portal hypertension assessment

    International Nuclear Information System (INIS)

    Artiko, V.; Kostic, K.; Perisic-Savic, M.; Janosevic, S.; Obradovic, V.

    2004-01-01

    The aim of this study is the presentation of the hepatic and splenic radionuclide angiograms (SRA) in various portal blood flow disturbances, as well as an analysis of the splenic arterio-venous ratio (SAVR) results, obtained as a slope ratio between inflow, arterial and the outflow, venous phases on the splenic TA curve. Splenic radionuclide angiography was performed after bolus injection of 740 MBq of 99m-Tc-pertechnetate, using ROTA scintillation camera (Siemens) and MicroDelta computer'. Four types of the SRA were established: a) very acute descendent slope (DS) in the controls; b) less acute DS in the patients with LC; c) horisontal venous phase caused by impaired outflow to the portal vein in LC with expressed portal hypertension, collateral circulation and LCEV; d) ascending outflow phase, characterizing the splenic and/or portal venous thrombosis. SAVR values were increased in liver cirrhosis (LC) with esophageal vahces (LCEV, n=10) (6.1 +/- 3.4) in comparison to the controls (n=10)(3.7 +/- 1.3)(U=25, p 0.05). However, in another two patients with LC and in 8 with LCEV it was not possible to access SAVR because of the appearance of the horisontal or rising venous phase on the splenic TA curve, instead of descendent. SRA and increased SAVR values reflect various blood flow alterations in the portal system and give additional data to the more accurate interpretation of the results obtained by hepatic radionuclide angiography. (authors)

  3. Airborne remote sensing of estuarine intertidal radionuclide concentrations

    International Nuclear Information System (INIS)

    Rainey, M.P.

    1999-08-01

    was assessed by comparison with in situ samples and the results of previous radiological studies within the estuary. Finally, detailed conclusions are made regarding radionuclide sinks and sources, and surface activity redistribution within the Ribble Estuary environment. (author)

  4. Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide {sup 99m}Tc to include new results for the LNE-LNHB and the NPL

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Courte, S.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Moune, M. [LNE-LNHB, Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel, Gif sur Yvette (France); Johansson, L.; Keightley, J. [National Physical Laboratory (NPL), Middlesex (United Kingdom)

    2010-12-15

    In 2007 and 2008 respectively, the Laboratoire national de metrologie et d'essais -Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of {sup 99m}Tc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. (authors)

  5. Direct comparison of 68Ga-DOTA-TOC and 18F-FDG PET/CT in the follow-up of patients with neuroendocrine tumour treated with the first full peptide receptor radionuclide therapy cycle

    International Nuclear Information System (INIS)

    Nilica, Bernhard; Waitz, Dietmar; Uprimny, Christian; Kendler, Dorota; Buxbaum, Sabine; Warwitz, Boris; Gerardo, Llanos; Virgolini, Irene; Rodrigues, Margarida; Stevanovic, Vlado; Henninger, Benjamin

    2016-01-01

    To determine the value of 68 Ga-DOTA-TOC and 18 F-FDG PET/CT for initial and follow-up evaluation of patients with neuroendocrine tumour (NET) treated with peptide receptor radionuclide therapy (PRRT). We evaluated 66 patients who had histologically proven NET and underwent both PRRT and three combined 68 Ga-DOTA-TOC and 18 F-FDG PET/CT studies. 68 Ga-DOTA-TOC PET/CT was performed before PRRT, 3 months after completion of PRRT and after a further 6 - 9 months. 18 F-FDG PET/CT was done within 2 months of 68 Ga-DOTA-TOC PET/CT. Follow-up ranged from 11.8 to 80.0 months (mean 34.5 months). All patients were 68 Ga-DOTA-TOC PET-positive initially and at follow-up after the first full PRRT cycle. Overall, 62 of the 198 18 F-FDG PET studies (31 %) were true-positive in 38 of the 66 patients (58 %). Of the 66 patients, 28 (5 grade 1, 23 grade 2) were 18 F-FDG-negative initially and during follow-up (group 1), 24 (5 grade 1, 13 grade 2, 6 grade 3) were 18 F-FDG-positive initially and during follow-up (group 2), 9 patients (2 grade 1, 6 grade 2, 1 grade 3) were 18 F-FDG-negative initially but 18 F-FDG-positive during follow-up (group 3), and 5 patients (all grade 2) were 18 F-FDG-positive initially but 18 F-FDG-negative during follow-up (group 4). 18 F-FDG PET showed more and/or larger metastases than 68 Ga-DOTA-TOC PET in five patients of group 2 and four patients of group 3, all with progressive disease. In three patients with progressive disease who died during follow-up tumour SUVmax increased by 41 - 82 % from the first to the last follow-up investigation. In NET patients, the presence of 18 F-FDG-positive tumours correlates strongly with a higher risk of progression. Initially, patients with 18 F-FDG-negative NET may show 18 F-FDG-positive tumours during follow-up. Also patients with grade 1 and grade 2 NET may have 18 F-FDG-positive tumours. Therefore, 18 F-FDG PET/CT is a complementary tool to 68 Ga-DOTA-TOC PET/CT with clinical relevance for molecular investigation

  6. Direct comparison of (68)Ga-DOTA-TOC and (18)F-FDG PET/CT in the follow-up of patients with neuroendocrine tumour treated with the first full peptide receptor radionuclide therapy cycle.

    Science.gov (United States)

    Nilica, Bernhard; Waitz, Dietmar; Stevanovic, Vlado; Uprimny, Christian; Kendler, Dorota; Buxbaum, Sabine; Warwitz, Boris; Gerardo, Llanos; Henninger, Benjamin; Virgolini, Irene; Rodrigues, Margarida

    2016-08-01

    To determine the value of (68)Ga-DOTA-TOC and (18)F-FDG PET/CT for initial and follow-up evaluation of patients with neuroendocrine tumour (NET) treated with peptide receptor radionuclide therapy (PRRT). We evaluated 66 patients who had histologically proven NET and underwent both PRRT and three combined (68)Ga-DOTA-TOC and (18)F-FDG PET/CT studies. (68)Ga-DOTA-TOC PET/CT was performed before PRRT, 3 months after completion of PRRT and after a further 6 - 9 months. (18)F-FDG PET/CT was done within 2 months of (68)Ga-DOTA-TOC PET/CT. Follow-up ranged from 11.8 to 80.0 months (mean 34.5 months). All patients were (68)Ga-DOTA-TOC PET-positive initially and at follow-up after the first full PRRT cycle. Overall, 62 of the 198 (18)F-FDG PET studies (31 %) were true-positive in 38 of the 66 patients (58 %). Of the 66 patients, 28 (5 grade 1, 23 grade 2) were (18)F-FDG-negative initially and during follow-up (group 1), 24 (5 grade 1, 13 grade 2, 6 grade 3) were (18)F-FDG-positive initially and during follow-up (group 2), 9 patients (2 grade 1, 6 grade 2, 1 grade 3) were (18)F-FDG-negative initially but (18)F-FDG-positive during follow-up (group 3), and 5 patients (all grade 2) were (18)F-FDG-positive initially but (18)F-FDG-negative during follow-up (group 4).(18)F-FDG PET showed more and/or larger metastases than (68)Ga-DOTA-TOC PET in five patients of group 2 and four patients of group 3, all with progressive disease. In three patients with progressive disease who died during follow-up tumour SUVmax increased by 41 - 82 % from the first to the last follow-up investigation. In NET patients, the presence of (18)F-FDG-positive tumours correlates strongly with a higher risk of progression. Initially, patients with (18)F-FDG-negative NET may show (18)F-FDG-positive tumours during follow-up. Also patients with grade 1 and grade 2 NET may have (18)F-FDG-positive tumours. Therefore, (18)F-FDG PET/CT is a complementary tool to (68)Ga-DOTA-TOC PET/CT with clinical

  7. The radionuclide migration model in river system

    International Nuclear Information System (INIS)

    Zhukova, O.M.; Shiryaeva, N.M.; Myshkina, M.K.; Shagalova, Eh.D.; Denisova, V.V.; Skurat, V.V.

    2001-01-01

    It was propose the model of radionuclide migration in river system based on principle of the compartmental model at hydraulically stationary and chemically equilibrium conditions of interaction of radionuclides in system water-dredge, water-sediments. Different conditions of radioactive contamination entry in river system were considered. The model was verified on the data of radiation monitoring of Iput' river

  8. Modeling Radionuclide Decay Chain Migration Using HYDROGEOCHEM

    Science.gov (United States)

    Lin, T. C.; Tsai, C. H.; Lai, K. H.; Chen, J. S.

    2014-12-01

    Nuclear technology has been employed for energy production for several decades. Although people receive many benefits from nuclear energy, there are inevitably environmental pollutions as well as human health threats posed by the radioactive materials releases from nuclear waste disposed in geological repositories or accidental releases of radionuclides from nuclear facilities. Theoretical studies have been undertaken to understand the transport of radionuclides in subsurface environments because that the radionuclide transport in groundwater is one of the main pathway in exposure scenarios for the intake of radionuclides. The radionuclide transport in groundwater can be predicted using analytical solution as well as numerical models. In this study, we simulate the transport of the radionuclide decay chain using HYDROGEOCHEM. The simulated results are verified against the analytical solution available in the literature. Excellent agreements between the numerical simulation and the analytical are observed for a wide spectrum of concentration. HYDROGECHEM is a useful tool assessing the ecological and environmental impact of the accidental radionuclide releases such as the Fukushima nuclear disaster where multiple radionuclides leaked through the reactor, subsequently contaminating the local groundwater and ocean seawater in the vicinity of the nuclear plant.

  9. Fire fighting in a radionuclide laboratory

    International Nuclear Information System (INIS)

    Wenzel, H.

    1991-01-01

    A fire-brigade was called to a laboratory which held a handling licence for the radionuclides C-14, T, P-32, Se-75, Mo-99, and S-35. The fire-brigade was unaware of a release of radionuclides. Therefore they used respiratory equipment, and all persons present were subsequently examined for contamination. (DG) [de

  10. Mechanisms of radionuclide transition in natural environment

    International Nuclear Information System (INIS)

    Pacyna, J.

    1974-01-01

    Mechanisms of radionuclide transition in various elements of the environment have been dealt with in an ecological aspect. The knowledge of the radionuclide propagation tracks will make possible to ascertain precisely causes and effects of the radiation and to reduce the contamination value. Particular attention has been paid to test methods. (author)

  11. Sensors and Automated Analyzers for Radionuclides

    International Nuclear Information System (INIS)

    Grate, Jay W.; Egorov, Oleg B.

    2003-01-01

    The production of nuclear weapons materials has generated large quantities of nuclear waste and significant environmental contamination. We have developed new, rapid, automated methods for determination of radionuclides using sequential injection methodologies to automate extraction chromatographic separations, with on-line flow-through scintillation counting for real time detection. This work has progressed in two main areas: radionuclide sensors for water monitoring and automated radiochemical analyzers for monitoring nuclear waste processing operations. Radionuclide sensors have been developed that collect and concentrate radionuclides in preconcentrating minicolumns with dual functionality: chemical selectivity for radionuclide capture and scintillation for signal output. These sensors can detect pertechnetate to below regulatory levels and have been engineered into a prototype for field testing. A fully automated process monitor has been developed for total technetium in nuclear waste streams. This instrument performs sample acidification, speciation adjustment, separation and detection in fifteen minutes or less

  12. Speciation of radionuclides in the environment

    International Nuclear Information System (INIS)

    Gunten, H.R. von; Benes, P.

    1994-02-01

    Methods for the determination of the speciation of radionuclides in aerosols, in aquatic solutions, in sediments, soils and rocks are reviewed. At present, most of the results about speciation are deduced from model calculations, model experiments, and separation of species (forms) of radionuclides, e.g., by sequential extraction procedures. Methods of direct determination of speciation of radionuclides (e.g. by laser induced spectroscopy) are in general not yet sensitive enough for a measurement of the very low concentrations of radionuclides in the environment. The methodological part of this paper is followed by a review of the very abundant literature about speciation of important radionuclides in the environment, i.e. in the atmosphere, hydrosphere and lithosphere. The review does not include the biosphere. Literature up to spring 1993 is included (with a few more recent additions). (author)

  13. Radionuclide transport in a single fissure

    International Nuclear Information System (INIS)

    Eriksen, T.E.

    1983-01-01

    Radionuclide migration have been studied in natural fissures orieted parallel to the axis of granite drill cores. A short pulse of the radionuclides solution was injected at one end of the fissure and the temporal change in radionuclide concentration of the eluate measured. After several hundred fissure volumes water had been pumped through the fissure following the radionuclide pulse the activity distribution on the fissure surfaces was measured. From the retardation of 152 Eu, 235 Np and 237 Pu it is concluded that these radionuclides are transported in the oxidation states Eu(III), Pu(IV) and Np(V). The distribution coefficients K sub (d) calculated from flow and activity distribution data on the basis of geometric surface area/volume ratios are of the same order as published K sub (d) values obtained from batch equilibrium experiments. (Author)

  14. Radionuclides in the environment: Risks and opportunities

    International Nuclear Information System (INIS)

    Elzerman, A.W.

    1993-01-01

    Environmental chemistry plays a critical role in the open-quotes nuclear ageclose quotes. It makes a vital contribution to understanding of the sources, fate and effects of radionuclides in the environment, both man-made and natural. Risk assessment of radionuclides in the environment relies heavily on the tools of environmental chemistry. On the other hand, radionuclides provide unique opportunities to exploit in environmental chemistry investigations due to their well-defined sources, traceability in environmental processes, analytical sensitivities, and open-quotes built-inclose quotes radioactive decay open-quotes clocksclose quotes. In some cases naturally present radionuclides are utilized, while in others tracers are deliberately added or have already been added by the nuclear fuel cycle or nuclear testing. Several examples in each of these categories are discussed to spotlight the current status of environmental chemistry and radionuclides in the environment as an example application

  15. Mobility and Bioavailability of Radionuclides in Soils

    International Nuclear Information System (INIS)

    Iurian, A.; Olufemi Phaneuf, M.; Mabit, L.

    2016-01-01

    It is crucial to understand the behavior of radionuclides in the environment, their potential mobility and bioavailability related to long-term persistence, radiological hazards, and impact on human health. Such key information is used to develop strategies that support policy decisions. The environmental behavior of radionuclides depends on ecosystem characteristics. A given soil’s capacity to immobilize radionuclides has been proved to be the main factor responsible for their resulting activity concentrations in plants. The mobility and bioavailability of radionuclides in soils is complex, depending on clay-sized soil fraction, clay mineralogy, organic matter, cation exchange capacity, pH and quantities of competing cations. Moreover, plant species have different behaviors regarding radionuclide absorption depending on soil and plan characteristics

  16. Radionuclides release possibility analysis of MSR at various accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choong Wie; Kim, Hee Reyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    There are some accidents which go beyond our expectation such as Fukushima Daiichi nuclear disaster and amounts of radionuclides release to environment, so more effort and research are conducted to prevent it. MSR (Molten Salt Reactor) is one of GEN-IV reactor types, and its coolant and fuel are mixtures of molten salt. MSR has a schematic like figure 1 and it has different features with the solid fuel reactor, but most important and interesting feature of MSR is its many safety systems. For example, MSR has a large negative void coefficient. Even though power increases, the reactor slows down soon. Radionuclides release possibility of MSR was analyzed at various accident conditions including Chernobyl and Fukushima ones. The MSR was understood to prevent the severe accident by the negative reactivity coefficient and the absence of explosive material such as water at the Chernobyl disaster condition. It was expected to contain fuel salts in the reactor building and not to release radionuclides into environment even if the primary system could be ruptured or broken and fuel salts would be leaked at the Fukushima Daiichi nuclear disaster condition of earthquake and tsunami. The MSR, which would not lead to the severe accident and therefore prevents the fuel release to the environment at many expected scenarios, was thought to have priority in the aspect of accidents. A quantitative analysis and a further research are needed to evaluate the possibility of radionuclide release to the environment at the various accident conditions based on the simple comparison of the safety feature between MSR and solid fuel reactor.

  17. A model to predict the level of artificial radionuclides in environmental materials in the Severn Estuary and the Bristol Channel

    International Nuclear Information System (INIS)

    McColl, N.P.

    1988-01-01

    The NRPB SEVERN compartment model, of the Bristol Channel and Severn Estuary, has been developed for used in predicting environmental concentrations of artificial radionuclides present in the estuary. A comparison between predicted and measured values of salinity and environmental 137 Cs concentrations has demonstrated the overall validity of the model. SEVERN has been used to assess the radiological impact of radionuclides present in the estuary which result from low-level routine discharges from the nuclear power industry. (author)

  18. On the assessment of radionuclide resorption from the gastro-intestinal tract of the blood

    International Nuclear Information System (INIS)

    Steinhilber-Schwab, B.; Teufel, D.

    1980-01-01

    A comparison of the resorption rates measured for the radionuclides Ce, Co, Pu, Ru, Sr and Zn as well as the vitamin B12 with the recommendations for calculation given by the SSK showed that the values used by the SSK partly are too low by orders of magnitude. The dose factors therefore no longer correspond to the international level of science. (DG) [de

  19. Radionuclide imaging of spinal infections

    International Nuclear Information System (INIS)

    Gemmel, Filip; Dumarey, Nicolas; Palestro, Christopher J.

    2006-01-01

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor 99m Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and 67 Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [ 18 F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including radiolabelled

  20. Radionuclide imaging of spinal infections

    Energy Technology Data Exchange (ETDEWEB)

    Gemmel, Filip [Ghent Maria-Middelares, General Hospital, Division of Nuclear Medicine, Ghent (Belgium); Medical Center Leeuwarden (MCL), Division of Nuclear Medicine, Henri Dunantweg 2, Postbus 888, Leeuwarden (Netherlands); Dumarey, Nicolas [Universite Libre de Bruxelles, Hopital Erasme, Division of Nuclear Medicine, Brussels (Belgium); Palestro, Christopher J. [Long Island Jewish Medical Center, Division of Nuclear Medicine, Long Island, NY (United States)

    2006-10-15

    The diagnosis of spinal infection, with or without implants, has been a challenge for physicians for many years. Spinal infections are now being recognised more frequently, owing to aging of the population and the increasing use of spinal-fusion surgery. The diagnosis in many cases is delayed, and this may result in permanent neurological damage or even death. Laboratory evidence of infection is variable. Conventional radiography and radionuclide bone imaging lack both sensitivity and specificity. Neither in vitro labelled leucocyte scintigraphy nor {sup 99m}Tc-anti-granulocyte antibody scintigraphy is especially useful, because of the frequency with which spinal infection presents as a non-specific photopenic area on these tests. Sequential bone/gallium imaging and {sup 67}Ga-SPECT are currently the radionuclide procedures of choice for spinal osteomyelitis, but these tests lack specificity, suffer from poor spatial resolution and require several days to complete. [{sup 18}F]Fluoro-2-deoxy-D-glucose (FDG) PET is a promising technique for diagnosing spinal infection, and has several potential advantages over conventional radionuclide tests. The study is sensitive and is completed in a single session, and image quality is superior to that obtained with single-photon emitting tracers. The specificity of FDG-PET may also be superior to that of conventional tracers because degenerative bone disease and fractures usually do not produce intense FDG uptake; moreover, spinal implants do not affect FDG imaging. However, FDG-PET images have to be read with caution in patients with instrumented spinal-fusion surgery since non-specific accumulation of FDG around the fusion material is not uncommon. In the future, PET-CT will likely provide more precise localisation of abnormalities. FDG-PET may prove to be useful for monitoring response to treatment in patients with spinal osteomyelitis. Other tracers for diagnosing spinal osteomyelitis are also under investigation, including

  1. The influence of the unsaturated zone on the upward transport of radionuclides in soils

    International Nuclear Information System (INIS)

    Elert, M.; Lindgren, M.

    1993-07-01

    The transport of radionuclides from the deep soil to the surface soil is an important part of biosphere modelling. In this study the effect of transient hydrological conditions on the upward transport of radionuclides through soils has been studied. The effect of varying soil properties, climate conditions have been considered as well as the effect of a fluctuating groundwater level. It was shown that the soil characteristics influences the radionuclide concentration; an increased hydraulic conductivity leads to increase in the concentration in the root zone. The climate conditions were shown to be of major importance. A dispersion dependent on both velocity and saturation leads to a more effective upward transport of radionuclides to the root zone than if dispersion is assumed to be dependent only on the saturation. The boundary condition used in the case with varying groundwater level may be more realistic than the boundary condition applied for the case with a constant groundwater level. All calculations with varying groundwater level gave lower radionuclide concentration in the root zone. Sorption is redox sensitive for many radionuclides and the redox potential in the soil will be affected by the degree of water saturation. The performed calculations did, however, not result in any significant change in the radionuclide concentration in the root zone due to variation in sorption. A comparison between the results of the two models show that the compartment model in all studied cases predicts a higher annual average radionuclide concentration in the root zone than the numerical model. Annual variation in soil water flow were not included in the compartment model. During the summer the concentration in the root zone may be several times higher than the annual average. This may be important for plant uptake, since this increased concentrations coincides with the plant growing season. The calculations made with the simple compartment model also show that these

  2. Effect of chronic L-thyroxine-suppressive therapy on cardiac function in patients with differentiated thyroid carcinoma: Radionuclide techniques

    International Nuclear Information System (INIS)

    Ziada, G.; Farouk, S.; Zidan, A.; Mustafa, S.; El-Reffaie, S.

    2005-01-01

    Differentiated thyroid carcinoma (DTC) is usually treated by a combination of surgery, radioiodine (I-131) and suppressive doses of thyroid hormones [L-thyroxine (Eltroxine)]. It is well-known that thyroid hormone affects the function of cardiovascular system. However there is no study to objectively substantiate this phenomenon. The objective of this study was to assess the left ventricular function with the help of radionuclide ventriculography in patients of DTC. Various parameters of systolic function [ejection fraction (EF), peak ejection rate (PER) and time to peak ejection rate (TPER)], diastolic function [peak filling rate (PFR) and time to peak filling rate (TPFR)] and heart rate were determined. Ten healthy control subjects and 50 patients of DTC on suppressive doses of eltroxine following surgery and radio-iodine (I-131) therapy were evaluated. The patients were divided into 5 groups according to their clinical status and thyroid hormone profile. These groups were: euthyroid, sub-clinical hypothyroid, hypothyroid, sub-clinical hyperthyroid and hyperthyroid groups. The results of the study revealed that Eltroxine significantly affected left ventricular function. Although it did not affect the systolic function, the diastolic function was significantly impaired. Prolongation of TPER was noted in hypothyroid patients, while the same was significantly decreased in hyper- and sub-clinical hyper-thyroids patients. Such abnormalities in cardiac function would be responsible for serious morbidity and could affect the lives of patients' in several ways. Hence, early effective treatment of thyroid function is important in patients of DTC, which would improve their quality of life and avoid long-term serious or irreversible cardiovascular disorder. (author)

  3. Radionuclide interactions with marine sediments

    International Nuclear Information System (INIS)

    Higgo, J.J.W.

    1987-09-01

    A critical review of the literature on the subject of the interactions of radionuclides with marine sediments has been carried out. On the basis of the information available, an attempt has been made to give ranges and 'best estimates' for the distribution ratios between seawater and sediments. These estimates have been based on an understanding of the sediment seawater system and the porewater chemistry and mineralogy. Field measurements, laboratory measurements and estimates based on stable-element geochemical data are all taken into account. Laboratory measurements include distribution-ratio and diffusion-coefficient determinations. The elements reviewed are carbon, chlorine, calcium, nickel, selenium, strontium, zirconium, niobium, technetium, tin, iodine, caesium, lead, radium, actinium, thorium, protactinium, uranium, neptunium, plutonium, americium and curium. (author)

  4. Expert system based radionuclide identification

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Ala-Heikkil, J.J.; Hakulinen, T.T.; Nikkinen, M.T.

    1998-01-01

    An expert system coupled with the gamma spectrum analysis system SAMPO has been developed for automating the qualitative identification of radionuclides as well as for determining the quantitative parameters of the spectrum components. The program is written in C-language and runs in various environments ranging from PCs to UNIX workstations. The expert system utilizes a complete gamma library with over 2600 nuclides and 80,000 lines, and a rule base of about fifty criteria including energies, relative peak intensities, genesis modes, half lives, parent-daughter relationships, etc. The rule base is furthermore extensible by the user. This is not an original contribution but a somewhat updated version of papers and reports previously published elsewhere. (author)

  5. Radionuclide diagnosis of allograft rejection

    International Nuclear Information System (INIS)

    George, E.A.

    1982-01-01

    Interaction with one or more anatomical and physiopathological characteristics of the rejecting renal allograft is suggested by those radioagents utilized specifically for the diagnosis of allograft rejection. Rejection, the most common cause of declining allograft function, is frequently mimicked clinically or masked by other immediate or long term post transplant complications. Understanding of the anatomical pathological features and kinetics of rejection and their modification by immunosuppressive maintenance and therapy are important for the proper clinical utilization of these radioagents. Furthermore, in selecting these radionuclides, one has to consider the comparative availability, preparatory and procedural simplicity, acquisition and display techniques and the possibility of timely report. The clinical utilities of radiofibrinogen, /sup 99m/Tc sulfur colloid and 67 Ga in the diagnosis of allograft rejection have been evaluated to a variable extent in the past. The potential usefulness of the recently developed preparations of 111 In labeled autologous leukocytes and platelets are presently under investigation

  6. Quality assurance in radionuclide laboratories

    International Nuclear Information System (INIS)

    Otto, R.; Voelkle, H.; Wershofen, H.; Wilhelm, C.

    2003-01-01

    The authors are members of an ad-hoc working group preparing a contribution to the procedures manual (''Loseblattsammlung'') dealing with quality assurance and quality control in radionuclide laboratories. The Loseblattsammlung is edited by the working group ''Environmental Monitoring'' of the German-Swiss Radiological Protection Association. The intention of the manual under preparation is not to give a procedure on how to establish a quality management system allowing for an accreditation in accordance with the international standard DIN EN ISO/IEC 17025:2000 04 (''ISO 17025'') [1] but to compile routine quality control procedures necessary for reliable measurements and to give tips to the practitioner on how to keep both the extent and the frequency of procedures on a reasonable level. A short version of the Loseblatt is presented here. (orig.)

  7. Placental transfer of other radionuclides

    International Nuclear Information System (INIS)

    Stieve, F.-E.

    1987-01-01

    This paper comments upon some basic principles of the transfer of radioactive substances in human beings to the embryo and fetus and their age-dependence. These principles may apply to the main effects currently known from the uptake, accumulation, retention and excretion of those radioactive substances, which may be of special interest in assessing the dose and therefore the risk of exposure in nuclear medicine, in connection with environmental problems of nuclear power production as well as nuclear explosions. As an example the age-dependence of several typical radionuclides and their age-dependence during the development of the human embryo and fetus and its correlation to observations on several animal species are presented. 30 refs.; 5 figs

  8. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  9. Radionuclide evaluation of brain death

    International Nuclear Information System (INIS)

    Pjura, G.A.; Kim, E.E.

    1987-01-01

    The criteria employed for clinical determination of death have evolved in response to advances in life support and other medical technology. The technical feasibility of organ transplantation has amplified the need for a definition of brain death that can be applied in the shortest possible time in the presence of artificial maintenance of vegetative functions, including circulation. Radionuclide cerebral angiography is one of a group of diagnostic procedures that can be employed to confirm the clinical diagnosis of brain death through demonstration of absence of cerebral blood flow. The focus of this work is to assess its use as a confirmatory test for determination of brain death in the context of currently available alternative technologies

  10. Radionuclide diagnosis of vasculogenic impotence

    International Nuclear Information System (INIS)

    Sorokin, A.I.; Gerasimov, V.G.; Lenskaya, O.P.; Narkevich, B.Ya.; Bogdasarov, Yu.B.; Krotovskij, G.S.

    1988-01-01

    Pathogenesis of vasculogenic impotence is most adequately revealed by modern methods of the investigation of the hemodynamic mechanisms of erection with the enhancement of arterial perfusion of corpora cavernosa by artificial sexual stimulation. Radionuclide diagnostic methods effectively differ from the methods of radiocontrast phalloangiography by the simplicity of investigation and the absence of traumatism for a patient. The authors have proposed a mathematical model of a process of filling in the functioning volume of the penile vascular bed with a radiopharmaceutical prepation against the background of erection induced by intracavernous administration of papaverine hydrochloride solution. Parameters of the model determine the ratio of blood flow volumetric rates in the penis at rest and when erect

  11. Comparison of sequential planar 177Lu-DOTA-TATE dosimetry scans with 68Ga-DOTA-TATE PET/CT images in patients with metastasized neuroendocrine tumours undergoing peptide receptor radionuclide therapy

    International Nuclear Information System (INIS)

    Sainz-Esteban, Aurora; Carril, Jose Manuel; Prasad, Vikas; Schuchardt, Christiane; Zachert, Carolin; Baum, Richard P.

    2012-01-01

    The aim of the study was to compare sequential 177 Lu-DOTA-TATE planar scans ( 177 Lu-DOTA-TATE) in patients with metastasized neuroendocrine tumours (NET) acquired during peptide receptor radionuclide therapy (PRRT) for dosimetry purposes with the pre-therapeutic 68 Ga-DOTA-TATE positron emission tomography (PET)/CT ( 68 Ga-DOTA-TATE) maximum intensity projection (MIP) images obtained in the same patients concerning the sensitivity of the different methods. A total of 44 patients (59 ± 11 years old) with biopsy-proven NET underwent 68 Ga-DOTA-TATE and 177 Lu-DOTA-TATE imaging within 7.9 ± 7.5 days between the two examinations. 177 Lu-DOTA-TATE planar images were acquired at 0.5, 2, 24, 48 and 72 h post-injection; lesions were given a score from 0 to 4 depending on the uptake of the radiopharmaceutical (0 being lowest and 4 highest). The number of tumour lesions which were identified on 177 Lu-DOTA-TATE scans (in relation to the acquisition time after injection of the therapeutic dose as well as with regard to the body region) was compared to those detected on 68 Ga-DOTA-TATE studies obtained before PRRT. A total of 318 lesions were detected; 280 (88%) lesions were concordant. Among the discordant lesions, 29 were 68 Ga-DOTA-TATE positive and 177 Lu-DOTA-TATE negative, whereas 9 were 68 Ga-DOTA-TATE negative and 177 Lu-DOTA-TATE positive. The sensitivity, positive predictive value and accuracy for 177 Lu-DOTA-TATE as compared to 68 Ga-DOTA-TATE were 91, 97 and 88%, respectively. Significantly more lesions were seen on the delayed (72 h) 177 Lu-DOTA-TATE images (91%) as compared to the immediate (30 min) images (68%). The highest concordance was observed for bone metastases (97%) and the lowest for head/neck lesions (75%). Concordant lesions (n = 77; mean size 3.8 cm) were significantly larger than discordant lesions (n = 38; mean size 1.6 cm) (p max ). However, concordant liver lesions with a score from 1 to 3 in the 72-h 177 Lu-DOTA-TATE scan had a lower SUV max

  12. Comparison of sequential planar {sup 177}Lu-DOTA-TATE dosimetry scans with {sup 68}Ga-DOTA-TATE PET/CT images in patients with metastasized neuroendocrine tumours undergoing peptide receptor radionuclide therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sainz-Esteban, Aurora; Carril, Jose Manuel [Hospital Universitario Marques de Valdecilla, Department of Nuclear Medicine, Santander (Spain); Prasad, Vikas; Schuchardt, Christiane; Zachert, Carolin; Baum, Richard P. [Zentralklinik Bad Berka, Department of Nuclear Medicine and Centre for PET/CT, Bad Berka (Germany)

    2012-03-15

    The aim of the study was to compare sequential {sup 177}Lu-DOTA-TATE planar scans ({sup 177}Lu-DOTA-TATE) in patients with metastasized neuroendocrine tumours (NET) acquired during peptide receptor radionuclide therapy (PRRT) for dosimetry purposes with the pre-therapeutic {sup 68}Ga-DOTA-TATE positron emission tomography (PET)/CT ({sup 68}Ga-DOTA-TATE) maximum intensity projection (MIP) images obtained in the same patients concerning the sensitivity of the different methods. A total of 44 patients (59 {+-} 11 years old) with biopsy-proven NET underwent {sup 68}Ga-DOTA-TATE and {sup 177}Lu-DOTA-TATE imaging within 7.9 {+-} 7.5 days between the two examinations. {sup 177}Lu-DOTA-TATE planar images were acquired at 0.5, 2, 24, 48 and 72 h post-injection; lesions were given a score from 0 to 4 depending on the uptake of the radiopharmaceutical (0 being lowest and 4 highest). The number of tumour lesions which were identified on {sup 177}Lu-DOTA-TATE scans (in relation to the acquisition time after injection of the therapeutic dose as well as with regard to the body region) was compared to those detected on {sup 68}Ga-DOTA-TATE studies obtained before PRRT. A total of 318 lesions were detected; 280 (88%) lesions were concordant. Among the discordant lesions, 29 were {sup 68}Ga-DOTA-TATE positive and {sup 177}Lu-DOTA-TATE negative, whereas 9 were {sup 68}Ga-DOTA-TATE negative and {sup 177}Lu-DOTA-TATE positive. The sensitivity, positive predictive value and accuracy for {sup 177}Lu-DOTA-TATE as compared to {sup 68}Ga-DOTA-TATE were 91, 97 and 88%, respectively. Significantly more lesions were seen on the delayed (72 h) {sup 177}Lu-DOTA-TATE images (91%) as compared to the immediate (30 min) images (68%). The highest concordance was observed for bone metastases (97%) and the lowest for head/neck lesions (75%). Concordant lesions (n = 77; mean size 3.8 cm) were significantly larger than discordant lesions (n = 38; mean size 1.6 cm) (p < 0.05). No such significance was

  13. Decontamination of radionuclides in food

    Energy Technology Data Exchange (ETDEWEB)

    Ohmomo, Yoichiro [Institute for Environmental Sciences, Aomori (Japan)

    1994-03-01

    The release of radionuclides arising from the Chernobyle accident led to widespread contamination of the northern hemisphere through fallout. This accident provided again an opportunity to investigate how and to what extent the radionuclides contamination in crops and animal derived foods could be reduced. The following topics are included in this paper. (1) How to reduce the transfer of radiostrontium and/or cesium from soil to crops: A pH increase of soil is effective for reducing their plant uptake. (2) How to reduce the transfer of radiocesium to animal derived foods: Ammonium-ferric-cyanoferrate (AFCF) should be the most effective compound for radiocesium excretion in the feces. Experiments with lactating cows and/or poultry gave extremely good results with respect to low radiocesium concentrations in milk, meat and eggs. (3) Removal coefficients of radiostrontium, cesium and iodine from contaminated leaf vegetables and cereals during food processing and culinary preparation: Though different by species, more than 80% of cesium and about 50% of strontium and iodine can be removed during culinary preparation of washing and boiling. (4) Simultaneous decontamination of radiocesium and iodine from drinking water and liquid milk: Metal ferrocyanide-anion exchange resin, specifically Fe ferrocyanide one, was successfully used for a rapid and simple decontamination of radiocesium and iodine in the liquid samples arising from the Chernobyle accident. (5) Removal of radiocesium from meat: The meat structurally contaminated with radiocesium is easily and very successfully decontaminated by pickling in NaCl solution and the decontamination is much speeded up by freezing meat before pickling. (author).

  14. Illicit Trafficking of Natural Radionuclides

    International Nuclear Information System (INIS)

    Friedrich, Steinhaeusler; Lyudmila, Zaitseva

    2008-01-01

    Natural radionuclides have been subject to trafficking worldwide, involving natural uranium ore (U 238), processed uranium (yellow cake), low enriched uranium ( 20% U 235), radium (Ra 226), polonium (Po 210), and natural thorium ore (Th 232). An important prerequisite to successful illicit trafficking activities is access to a suitable logistical infrastructure enabling an undercover shipment of radioactive materials and, in case of trafficking natural uranium or thorium ore, capable of transporting large volumes of material. Covert en route diversion of an authorised uranium transport, together with covert diversion of uranium concentrate from an operating or closed uranium mines or mills, are subject of case studies. Such cases, involving Israel, Iran, Pakistan and Libya, have been analyzed in terms of international actors involved and methods deployed. Using international incident data contained in the Database on Nuclear Smuggling, Theft and Orphan Radiation Sources (DSTO) and international experience gained from the fight against drug trafficking, a generic Trafficking Pathway Model (TPM) is developed for trafficking of natural radionuclides. The TPM covers the complete trafficking cycle, ranging from material diversion, covert material transport, material concealment, and all associated operational procedures. The model subdivides the trafficking cycle into five phases: (1) Material diversion by insider(s) or initiation by outsider(s); (2) Covert transport; (3) Material brokerage; (4) Material sale; (5) Material delivery. An Action Plan is recommended, addressing the strengthening of the national infrastructure for material protection and accounting, development of higher standards of good governance, and needs for improving the control system deployed by customs, border guards and security forces

  15. Illicit Trafficking of Natural Radionuclides

    Science.gov (United States)

    Friedrich, Steinhäusler; Lyudmila, Zaitseva

    2008-08-01

    Natural radionuclides have been subject to trafficking worldwide, involving natural uranium ore (U 238), processed uranium (yellow cake), low enriched uranium (20% U 235), radium (Ra 226), polonium (Po 210), and natural thorium ore (Th 232). An important prerequisite to successful illicit trafficking activities is access to a suitable logistical infrastructure enabling an undercover shipment of radioactive materials and, in case of trafficking natural uranium or thorium ore, capable of transporting large volumes of material. Covert en route diversion of an authorised uranium transport, together with covert diversion of uranium concentrate from an operating or closed uranium mines or mills, are subject of case studies. Such cases, involving Israel, Iran, Pakistan and Libya, have been analyzed in terms of international actors involved and methods deployed. Using international incident data contained in the Database on Nuclear Smuggling, Theft and Orphan Radiation Sources (DSTO) and international experience gained from the fight against drug trafficking, a generic Trafficking Pathway Model (TPM) is developed for trafficking of natural radionuclides. The TPM covers the complete trafficking cycle, ranging from material diversion, covert material transport, material concealment, and all associated operational procedures. The model subdivides the trafficking cycle into five phases: (1) Material diversion by insider(s) or initiation by outsider(s); (2) Covert transport; (3) Material brokerage; (4) Material sale; (5) Material delivery. An Action Plan is recommended, addressing the strengthening of the national infrastructure for material protection and accounting, development of higher standards of good governance, and needs for improving the control system deployed by customs, border guards and security forces.

  16. Decontamination of radionuclides in food

    International Nuclear Information System (INIS)

    Ohmomo, Yoichiro

    1994-01-01

    The release of radionuclides arising from the Chernobyle accident led to widespread contamination of the northern hemisphere through fallout. This accident provided again an opportunity to investigate how and to what extent the radionuclides contamination in crops and animal derived foods could be reduced. The following topics are included in this paper. (1) How to reduce the transfer of radiostrontium and/or cesium from soil to crops: A pH increase of soil is effective for reducing their plant uptake. (2) How to reduce the transfer of radiocesium to animal derived foods: Ammonium-ferric-cyanoferrate (AFCF) should be the most effective compound for radiocesium excretion in the feces. Experiments with lactating cows and/or poultry gave extremely good results with respect to low radiocesium concentrations in milk, meat and eggs. (3) Removal coefficients of radiostrontium, cesium and iodine from contaminated leaf vegetables and cereals during food processing and culinary preparation: Though different by species, more than 80% of cesium and about 50% of strontium and iodine can be removed during culinary preparation of washing and boiling. (4) Simultaneous decontamination of radiocesium and iodine from drinking water and liquid milk: Metal ferrocyanide-anion exchange resin, specifically Fe ferrocyanide one, was successfully used for a rapid and simple decontamination of radiocesium and iodine in the liquid samples arising from the Chernobyle accident. (5) Removal of radiocesium from meat: The meat structurally contaminated with radiocesium is easily and very successfully decontaminated by pickling in NaCl solution and the decontamination is much speeded up by freezing meat before pickling. (author)

  17. Model of the long-term transfer of radionuclides in forests

    International Nuclear Information System (INIS)

    Avila, Rodolfo

    2006-05-01

    . The model assumes that the fluxes of radionuclides are driven by fluxes of water and nutrients and hence the TCs are expressed as function of ecological parameters, such as biomass growth, and evapotranspiration. The following radionuclide fluxes are included in the model: flux from soil to tree wood via root uptake, flux from soil to tree leaves via root uptake, flux from soil to understorey (plants and mushrooms) via root (mycelia) uptake, flux from tree leaves to litter by leaves fall, flux from tree wood to litter by wood fall, flux from understorey plants to litter by plant senescence, flux from litter to soil following litter decomposition. In the report alternative approaches to describe the transfer from soil to plants are presented. In the simpler approach, applicable when soil to plant concentration ratios (CR) are available for the radionuclide or its stable analogue, the root uptake rates are calculated by multiplying the concentration in the plant, obtained with the help of the CR, by the biomass production. A second approach is based on the assumption that some elements are taken-up passively with the transpiration flux. For them, the total flux from soil to plants can be expressed as a function of the transpiration rate and the radionuclide concentration in the pore water. The CRs from soil to understorey plants as well as the CRs from soil to tree leaves and tree wood were estimated by performing probabilistic simulations. It was assumed that roots have the same permeability for radionuclides and water. It should be taken into account, that the literature data used in the comparison were obtained at different sites and using different methods. A better agreement could be achieved if the model parameters and the empirical data of CRs are obtained for the same site. In some cases the differences might abide more fundamental reasons, for instance that the implicit assumption of linear proportionality of the radionuclide uptake rates to the transpiration

  18. Model of the long-term transfer of radionuclides in forests

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo [Facilia AB, Bromma (Sweden)

    2006-05-15

    . The model assumes that the fluxes of radionuclides are driven by fluxes of water and nutrients and hence the TCs are expressed as function of ecological parameters, such as biomass growth, and evapotranspiration. The following radionuclide fluxes are included in the model: flux from soil to tree wood via root uptake, flux from soil to tree leaves via root uptake, flux from soil to understorey (plants and mushrooms) via root (mycelia) uptake, flux from tree leaves to litter by leaves fall, flux from tree wood to litter by wood fall, flux from understorey plants to litter by plant senescence, flux from litter to soil following litter decomposition. In the report alternative approaches to describe the transfer from soil to plants are presented. In the simpler approach, applicable when soil to plant concentration ratios (CR) are available for the radionuclide or its stable analogue, the root uptake rates are calculated by multiplying the concentration in the plant, obtained with the help of the CR, by the biomass production. A second approach is based on the assumption that some elements are taken-up passively with the transpiration flux. For them, the total flux from soil to plants can be expressed as a function of the transpiration rate and the radionuclide concentration in the pore water. The CRs from soil to understorey plants as well as the CRs from soil to tree leaves and tree wood were estimated by performing probabilistic simulations. It was assumed that roots have the same permeability for radionuclides and water. It should be taken into account, that the literature data used in the comparison were obtained at different sites and using different methods. A better agreement could be achieved if the model parameters and the empirical data of CRs are obtained for the same site. In some cases the differences might abide more fundamental reasons, for instance that the implicit assumption of linear proportionality of the radionuclide uptake rates to the transpiration

  19. Human dose pathways of radionuclides in forests

    International Nuclear Information System (INIS)

    Rantavaara, A.

    2009-01-01

    Forest soil, understorey vegetation and trees are all sources of radionuclides and human radiation doses after contaminating atmospheric deposition. People are exposed to radiation externally from sources outside the body and internally via ingestion and inhalation of radionuclides. Understorey vegetation contributes to ingestion doses through berries, herbs, wild honey, mushrooms and game meat; also trees provide feed to terrestrial birds and big game. During stay in forests people are subject to external radiation from forest floor and overstorey, and they may inhale airborne radioactive aerosol or gaseous radionuclides in ground level air. In the early phase of contamination also resuspended radionuclides may add to the internal dose of people via inhalation. People in Nordic countries are most exposed to radiation via ingestion of radionuclides in wild foods. The distribution of radionuclides in forests is changed by environmental processes, and thereby also the significance of various dose pathways to humans will change with time. External exposure is received in living environment from contaminated stemwood used as building timber and for manufacturing of furniture and other wood products. The aim of this paper is to outline the significance of various human dose pathways of radionuclides in forests considering the public and workers in forestry and production of bioenergy. Examples on effective doses are given based on two historical events, atmospheric nuclear weapon tests (mostly in 1950's and in 1960's) and the Chernobyl nuclear power plant accident in 1986. (au)

  20. Radionuclides: Accumulation and Transport in Plants.

    Science.gov (United States)

    Gupta, D K; Chatterjee, S; Datta, S; Voronina, A V; Walther, C

    Application of radioactive elements or radionuclides for anthropogenic use is a widespread phenomenon nowadays. Radionuclides undergo radioactive decays releasing ionizing radiation like gamma ray(s) and/or alpha or beta particles that can displace electrons in the living matter (like in DNA) and disturb its function. Radionuclides are highly hazardous pollutants of considerable impact on the environment, food chain and human health. Cleaning up of the contaminated environment through plants is a promising technology where the rhizosphere may play an important role. Plants belonging to the families of Brassicaceae, Papilionaceae, Caryophyllaceae, Poaceae, and Asteraceae are most important in this respect and offer the largest potential for heavy metal phytoremediation. Plants like Lactuca sativa L., Silybum marianum Gaertn., Centaurea cyanus L., Carthamus tinctorius L., Helianthus annuus and H. tuberosus are also important plants for heavy metal phytoremediation. However, transfer factors (TF) of radionuclide from soil/water to plant ([Radionuclide]plant/[Radionuclide]soil) vary widely in different plants. Rhizosphere, rhizobacteria and varied metal transporters like NRAMP, ZIP families CDF, ATPases (HMAs) family like P1B-ATPases, are involved in the radio-phytoremediation processes. This review will discuss recent advancements and potential application of plants for radionuclide removal from the environment.