WorldWideScience

Sample records for radiometric differentiation test

  1. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-01-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on 14 CO 2 evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of 14 CO 2 evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III

  2. Sterility test by radiometric technique

    International Nuclear Information System (INIS)

    Faruq, Muhammad

    1980-01-01

    Sterility test of pharmaceuticals can be carried out by the application of pharmacopoeia and radiometric technique. In Indonesia the application of pharmacopoeia technique is carried out through liquid germination for aerobacteria and for fungus and yeast. Radiometric technique is applied to autotrop and heterotrop bacteria. (SMN)

  3. Automation of radiometric testing

    International Nuclear Information System (INIS)

    Chekalin, A.S.; Temnik, A.K.; Butakova, G.E.; Goncharov, V.I.

    1983-01-01

    The main prerequisites for creation of automatic systems of radiometric testing as the means to increase the testing objectivity and quality have been considered, principles of their design being developed. The operating system is described for testing complex configuration products using RD-10R gamma flow detector as a sensor of initial information

  4. Urease testing of mycobacteria with BACTEC radiometric instrumentation

    International Nuclear Information System (INIS)

    Damato, J.J.; Collins, M.T.; McClatchy, J.K.

    1982-01-01

    A total of 140 mycobacterial isolates from patients treated at Fitzsimons Army Medical Center or the National Jewish Hospital and Research Center and from animal specimens submitted to the National Veterinary Services Laboratory were tested by using a urease procedure modified for use with a BACTEC model 301. Mycobacterial suspensions were prepared by using Middlebrook 7H10 Tween broth. Of the 98 mycobacteria isolates which were urease positive utilizing standard methodology, all were positive using the radiometric procedures. Similarly, all 42 urease-negative isolates were also negative employing the new methodology. Although maximum radiometric readings were observed at 48 h, all positive strains were readily identified 24 h after inoculation without sacrificing either test sensitivity or specificity. Thus, urease testing of mycobacteria, using the modified BACTEC radiometric methodology, was as sensitive, as specific, and more rapid than conventional methods

  5. Analysis of differential method for compensating fluctuations in product thickness when radiometric testing

    International Nuclear Information System (INIS)

    Pokrovskij, A.V.; Kvasnitsa, M.S.

    1979-01-01

    Given are the estimates of information capabilities of the differential method for measuring radiation flux in radiation defectoscopy as well as efficiency of application of automatic radiation facilities to control taking into account the statistical regularities of product thickness fluctuations. Dependences of signal to noise ratio on the regularities of product thickness fluctuations have been found and optimization, on this basis, of the design and parameters of processing instrumentation was carried out. It is shown, that with 60-80 mm interval of product thickness fluctuations correlation (welded joints) it is expedient to use two radiation beams with their crossing on a mean product plane. When the interval of correlation of thickness fluctuations is great it is effective to use the geometry of radioscopy with parallel radiation beams. This permits to use only one radiation source without significant reducing the compensation efficiency, that in most cases simplifies the development and application of radiometric systems. Thus the efficiency of applying the differential method for radiation beam detection to compensate product thickness fluctuations is primarily determined by statistical regularities of the given fluctuations. The account of the regularities in the development of the processing instrumentation results in the most complete extraction of useful information, containing in the radiation beams being detected

  6. Limulus test for pyrogens and radiometric sterility tests on radiopharmaceuticals. Part of a coordinated programme

    International Nuclear Information System (INIS)

    Gopal, N.G.S.

    1976-10-01

    Sterility testing of radiopharmaceuticals prepared at BARC were carried out using the radiometric technique (Radiometric detection of the metabolic product 14 Co 2 ). Batches of different radiopharmaceuticals were tested for pyrogen using the limulus lysate method and the results were compared with the rabbit method. The results of sterility test on 202 batches of 19 different radiopharmaceuticals show that the radiometric method can be used for sterility testing of radiopharmaceuticals labelled with 35 S, 51 Cr, 57 Co, 59 Fe, 82 Br, 86 Rb, sup(99m)Tc, sup(113m)In, 125 I and 169 Yb. The radiometric test proves to be more rapid than the conventional one for the sterility testing of such radiopharmaceuticals. Detection time is between 6-21 hours. In the case of 131 I-labelled radiopharmaceuticals and in the case of chlormerodrin-Hg-203, it was found an interference due to volatile species (sup(131m)Xe in the case of 131 I and some volatile mercury form in the case of chlormerodrin). In these cases it would be possible to carry out the radiometric sterility test after separation of the microorganisms from the radioactive material (by filtration). The limulus lysate method can be employed for control of various pyrogen-prone raw materials and radiopharmaceuticals. Such method is the only method at present available for detecting the low level pyrogen contamination in intrathecal injections. The limulus test is more rapid than the rabbit test

  7. The perspectives of development of radiometric techniques for welded joints testing

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Dovzhenko, V.N.

    1987-01-01

    The perspectives of development of radiometric techniques in non-destructive testing are presented. The problems of computer tomography, radiometric introscopy, electrorentgenography (xeroradiography) are reviewed. The aspects of application of low-silver detectors are also analysed. The studies on the problems mentioned above will be continued in order to eliminate expensive radiographic films and having in mind making the testing process faster. The design of individual dosemeters is also demonstrated. (author)

  8. Testing of X-ray radiometric enrichnment of polymetallic ores

    International Nuclear Information System (INIS)

    Eliseev, N.I.; Panova, N.I.; Kirbitova, N.V.; Shramm, E.O.; Efremov, Yu.G.

    1987-01-01

    Testing of X-ray radiometric method of sorting of polymetallic ores using the developed X-ray radiometric device was conducted. It was shown that introduction of preliminary concentration at the factory made the method of fragment separation to be the perspective one, enabling to elevate the factory production with respect to commercial ore and reduce the cost of ore processing. In the case of preliminary concentration, conducted at the mine, it is advisable to perform ore sorting in the flow formed to monolayer

  9. Radiometric diagnosis of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Laszlo, A.

    1986-01-01

    The results of this study confirm that rapid radiometric diagnostic tests such as the NAP selective inhibition test for the M. tuberculosis complex followed by the radiometric drug susceptibility tests are extremely reliable and compare favourably with conventional methodologies. This study also shows that referred cultures growing on solid medium can be processed by radiometric procedures without prior subculture. This circumstance by itself shortens the time needed for reporting. (Auth.)

  10. Evaluation of a rapid radiometric differentiation test for the Mycobacterium tuberculosis complex by selective inhibition with p-nitro-alpha-acetylamino-beta-hydroxypropiophenone

    International Nuclear Information System (INIS)

    Laszlo, A.; Siddiqi, S.H.

    1984-01-01

    This study is an evaluation of a rapid technique for the differentiation of the Mycobacterium tuberculosis complex from other mycobacteria, using p-nitro-alpha-acetylamino-beta- hydroxypropiophenone (NAP) as a selective inhibitory agent. A total of 416 coded cultures, 234 cultures belonging to the M. tuberculosis complex and 182 cultures belonging to 35 other mycobacterial species, were tested in two laboratories for p-nitro-alpha-acetylamino-beta- hydroxypropiophenone inhibition to concentrations of 5 and 10 micrograms of NAP per ml in Middlebrook 7H12 liquid medium. Two testing modes were compared: the indirect, in which a large bacterial inoculum was used from an isolated culture on a solid medium, and the direct, which used a small inoculum from 7H12 medium. A decrease or no increase in daily 14 CO 2 output as measured by a BACTEC system was considered evidence of inhibition. The data presented show that a concentration of 5 micrograms of NAP per ml can effectively separate the M. tuberculosis complex from other mycobacterial species in 4 to 6 days. The direct test data show that, unlike other conventional biochemical tests, it does not require a heavy inoculum of mycobacteria and can therefore be performed soon after growth is detected by the radiometric method

  11. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    Science.gov (United States)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  12. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  13. RADIOMETRIC BLOCK ADJUSMENT AND DIGITAL RADIOMETRIC MODEL GENERATION

    Directory of Open Access Journals (Sweden)

    A. Pros

    2013-05-01

    Full Text Available In this paper we present a radiometric block adjustment method that is related to geometric block adjustment and to the concept of a terrain Digital Radiometric Model (DRM as a complement to the terrain digital elevation and surface models. A DRM, in our concept, is a function that for each ground point returns a reflectance value and a Bidirectional Reflectance Distribution Function (BRDF. In a similar way to the terrain geometric reconstruction procedure, given an image block of some terrain area, we split the DRM generation in two phases: radiometric block adjustment and DRM generation. In the paper we concentrate on the radiometric block adjustment step, but we also describe a preliminary DRM generator. In the block adjustment step, after a radiometric pre-calibraton step, local atmosphere radiative transfer parameters, and ground reflectances and BRDFs at the radiometric tie points are estimated. This radiometric block adjustment is based on atmospheric radiative transfer (ART models, pre-selected BRDF models and radiometric ground control points. The proposed concept is implemented and applied in an experimental campaign, and the obtained results are presented. The DRM and orthophoto mosaics are generated showing no radiometric differences at the seam lines.

  14. Analysis of Properties of Reflectance Reference Targets for Permanent Radiometric Test Sites of High Resolution Airborne Imaging Systems

    Directory of Open Access Journals (Sweden)

    Eero Ahokas

    2010-08-01

    Full Text Available Reliable and optimal exploitation of rapidly developing airborne imaging methods requires geometric and radiometric quality assurance of production systems in operational conditions. Permanent test sites are the most promising approach for cost-efficient performance assessment. Optimal construction of permanent radiometric test sites for high resolution airborne imaging systems is an unresolved issue. The objective of this study was to assess the performance of commercially available gravels and painted and unpainted concrete targets for permanent, open-air radiometric test sites under sub-optimal climate conditions in Southern Finland. The reflectance spectrum and reflectance anisotropy and their stability were characterized during the summer of 2009. The management of reflectance anisotropy and stability were shown to be the key issues for better than 5% reflectance accuracy.

  15. A report of airbone radiometric and magnetic test survey

    International Nuclear Information System (INIS)

    Koo, J.H.; Park, Y.S.; Woo, S.M.

    1982-01-01

    By the end of Oct. 1981, a complete set of GeoMetrics' air-borne radiometric and magnetic survey system was purchased by KIER using the ADB loan, and it took one week from Nov. 11 1981 to install the system on a Bell 206 B helicopter (HL 9102) owned by Asia Aeroservice Company. The test survey was flown over an area including Hongseong, Daecheon, Seosan and Manripo Sheets, from Nov. 19 to Dec. 14 1981. A Hongseong air-strip was used as the base. (Author)

  16. MTG infrared sounder detection chain: first radiometric test results

    Science.gov (United States)

    Dumestier, D.; Pistone, F.; Dartois, T.; Blazquez, E.

    2017-11-01

    Europe's next fleet of geostationary meteorological satellites, MeteoSat Third Generation, will introduce new functions in addition to continuity of high-resolution meteorological data. The atmosphere Infrared Sounder (IRS), as high -end instrument, is part of this challenging program. IRS principle is a Fourier Transform Interferometer, which allows recomposing atmospheric spectrum after infrared photons detection. Transmission spectrums will be used to support numerical weather prediction. IRS instrument is able to offer full disk coverage in one hour, an on-ground resolution of 4 by 4 km, in two spectral bands (MWIR: 1600 to 2175cm-1 and LWIR: 700 to 1210cm-1) with a spectral resolution of 0.6cm-1. Among critical technologies and processes, IRS detection chain shall offer outstanding characteristics in terms of radiometric performance like Signal to Noise Ratio (SNR), dynamic range and linearity. Selected detectors are HgCdTe two-dimensions arrays, cooled at 55 Kelvins, hybridized on snapshot silicon read-out circuit at 160x160 format. Video electronics present 16 bits resolution, and the whole detection chain (Detectors and electronics) permits to reach SNR between 2 000 and 10 000 as requested by the application. Radiometric onground test results performed on design representative detection chains are presented and are confirming the challenging phase A design choices.

  17. New age radiometric ore sorting - the elegant solution

    International Nuclear Information System (INIS)

    Gordon, H.P.; Heuer, T.

    2000-01-01

    Radiometric ore sorting technology and application are described in two parts. Part I reviews the history of radiometric sorting in the minerals industry and describes the latest developments in radiometric sorting technology. Part II describes the history, feasibility study and approach used in the application of the new technology at Rossing Uranium Limited. There has been little progress in the field of radiometric sorting since the late 1970s. This has changed with the development of a high capacity radiometric sorter designed to operate on low-grade ore in the +75mm / -300mm size fraction. This has been designed specifically for an application at Rossing. Rossing has a long history in radiometric sorting dating back to 1968 when initial tests were conducted on the Rossing prospect. Past feasibility studies concluded that radiometric sorting would not conclusively reduce the unit cost of production unless sorting was used to increase production levels. The current feasibility study shows that the application of new radiometric sorter technology makes sorting viable without increasing production, and significantly more attractive with increased production. A pilot approach to confirm sorter performance is described. (author)

  18. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  19. Application of microcomputer to X-ray radiometric ore separation

    International Nuclear Information System (INIS)

    Neverov, A.D.; Aleksandrov, P.S.; Kotler, N.I.

    1988-01-01

    The practical use of microcomputers as universal means for converting information for solving applied problems of X-ray radiometric ore separation method is considered. Laboratory tests of two metals - tungsten and tin manifested high efficiency of the developed system. X-ray radiometric separator software is developed

  20. Study of a new radiometric sterility test in radiopharmaceuticals

    International Nuclear Information System (INIS)

    Sanchez P, A.R.

    1976-01-01

    A new radiometric method is studied for the determination of sterility. It is based on a culture marked with carbon-14 and the measurement by liquid scintillation of the radioactivity of the gaseous products released after a short period of incubation. The studied samples consisted in nonradioactive solutions and different radiopharmaceuticals, through a regulated current of nitrogen there is a transportation of gaseous and volatile products produced in each flask, which were received in a liquid scintillation vial. The experimental data permit to conclude that through the radiometric method the results can be obtained after 24 hours or less of incubation, instead of a period of several days which was necessary with the traditional process. Due to the sensitivity of the method it is possible to inoculate a minimum volume of sample, this is important in the case of the preparation of little parts for injection as it occurs generally with the pharmaceuticals. (author)

  1. Evaluation of a radiometric method for pyrazinamide susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Tarrand, J.J.; Spicer, A.D.; Groeschel, D.H.

    1986-01-01

    Pyrazinamide susceptibility testing of Mycobacterium tuberculosis requires an acid environment. By controlling the method of acidification and the quality and quantity of the inoculum, the test can be performed with the BACTEC radiometric system (Johnston Laboratories, Towson, Md.). We acidified BACTEC 7H12 medium with buffered phosphoric acid and adjusted the test inoculum to 1/10 of that usually employed in BACTEC protocols; after 5 days of growth we correctly identified 36 of 36 strains susceptible to 50 micrograms of pyrazinamide per ml. All 18 resistant strains were classified as pyrazinamide resistant. (Susceptibility or resistance had been determined by standard plate assays.) The test was able to detect small resistant populations in artificial mixtures of 1 or 2% resistant bacteria with a susceptible strain (10 mixtures each). We tested 70 M. tuberculosis strains in acidified BACTEC 7H12 medium and by the plate dilution test at pH 5.5. All strains grew in the BACTEC medium, but three strains failed to grow on plates and were not tested further; the results of both methods agreed for the remaining strains

  2. A large-scale radiometric micro-quantitative complement fixation test for serum antibody titration

    International Nuclear Information System (INIS)

    Bengali, Z.H.; Levine, P.H.; Das, S.R.

    1980-01-01

    A micro-quantitative complement fixation (CF) procedure based on 51 Cr release is described. The method employs 50% hemolysis as end point and the alternation equation to calculate the amount of complement involved in the hemolytic reaction. Compared to the conventional CF tests, the radiometric procedure described here is very precise and consistently reproducible. Also, since only 3 4-fold dilutions of sera are used for the titration of antibodies over a wide range of concentrations, the test is very concise and is economical to perform. Its format is amenable to automation and computerization. This radioimetric CF procedure is thus most useful for large-scale immunological research and epidemiological surveilance studies. (Auth.)

  3. PLEIADES-HR INNOVATIVE TECHNIQUES FOR RADIOMETRIC IMAGE QUALITY COMMISSIONING

    Directory of Open Access Journals (Sweden)

    G. Blanchet

    2012-07-01

    Full Text Available The first Pleiades-HR satellite, part of a constellation of two, has been launched on December 17, 2011. This satellite produces high resolution optical images. In order to achieve good image quality, Pleiades-HR should first undergo an important 6 month commissioning phase period. This phase consists in calibrating and assessing the radiometric and geometric image quality to offer the best images to end users. This new satellite has benefited from technology improvements in various fields which make it stand out from other Earth observation satellites. In particular, its best-in-class agility performance enables new calibration and assessment techniques. This paper is dedicated to presenting these innovative techniques that have been tested for the first time for the Pleiades- HR radiometric commissioning. Radiometric activities concern compression, absolute calibration, detector normalization, and refocusing operations, MTF (Modulation Transfer Function assessment, signal-to-noise ratio (SNR estimation, and tuning of the ground processing parameters. The radiometric performances of each activity are summarized in this paper.

  4. Wafer-level radiometric performance testing of uncooled microbolometer arrays

    Science.gov (United States)

    Dufour, Denis G.; Topart, Patrice; Tremblay, Bruno; Julien, Christian; Martin, Louis; Vachon, Carl

    2014-03-01

    A turn-key semi-automated test system was constructed to perform on-wafer testing of microbolometer arrays. The system allows for testing of several performance characteristics of ROIC-fabricated microbolometer arrays including NETD, SiTF, ROIC functionality, noise and matrix operability, both before and after microbolometer fabrication. The system accepts wafers up to 8 inches in diameter and performs automated wafer die mapping using a microscope camera. Once wafer mapping is completed, a custom-designed quick insertion 8-12 μm AR-coated Germanium viewport is placed and the chamber is pumped down to below 10-5 Torr, allowing for the evaluation of package-level focal plane array (FPA) performance. The probe card is electrically connected to an INO IRXCAM camera core, a versatile system that can be adapted to many types of ROICs using custom-built interface printed circuit boards (PCBs). We currently have the capability for testing 384x288, 35 μm pixel size and 160x120, 52 μm pixel size FPAs. For accurate NETD measurements, the system is designed to provide an F/1 view of two rail-mounted blackbodies seen through the Germanium window by the die under test. A master control computer automates the alignment of the probe card to the dies, the positioning of the blackbodies, FPA image frame acquisition using IRXCAM, as well as data analysis and storage. Radiometric measurement precision has been validated by packaging dies measured by the automated probing system and re-measuring the SiTF and Noise using INO's pre-existing benchtop system.

  5. Radiometric enrichment of nonradioactive ores

    International Nuclear Information System (INIS)

    Mokrousov, V.A.; Lileev, V.A.

    1979-01-01

    Considered are the methods of mineral enrichment based on the use of the radioation of various types. The physical essence of enrichment processes is presented, their classification is given. Described are the ore properties influencing the efficiency of radiometric enrichment, methods of the properties study and estimation of ore enrichment. New possibilities opened by radiometric enrichment in the technology of primary processing of mineral raw materials are elucidated. A considerable attention is paid to the main and auxiliary equipment for radiometric enrichment. The foundations of the safety engineering are presented in a brief form. Presented are also results of investigations and practical works in the field of enrichment of ores of non-ferrous, ferrous and non-metallic minerals with the help of radiometric methods

  6. The use of radiometric ore sorting on South African gold mines

    International Nuclear Information System (INIS)

    Boehme, R.C.; Freer, J.S.

    1982-01-01

    This paper refers to the radiometric sorting tests reported during the 7th CMMI Congress, and then describes the photometric and radiometric sorter installations in operation and under construction in South Africa at present. As radiometric sorting of gold ores uses the radiation from the uranium content as a tracer, it is essential that the sortability of the ore should be reliably determined before sorting is adopted. The method of obtaining the important ore characteristics is described, with examples. The possible increase in gold production from a hypothetical plant as a result of sorting is shown

  7. Radiometric measurement techniques in metallurgy and foundry technology

    International Nuclear Information System (INIS)

    1990-01-01

    The contributions contain informations concerning the present state and development of radiometric measurement techniques in metallurgy and foundry technology as well as their application to the solution of various problems. The development of isotope techniques is briefly described. Major applications of radiometric equipment in industrial measurement are presented together with the use of isotopes to monitor processes of industrial production. This is followed by a short description of numerous laboratory-scale applications. Another contribution deals with fundamental problems and methods of moisture measurement by neutrons. A complex moisture/density measurement device the practical applicability of which has been tested is described here. Possibilities for clay determination in used-up moulding materials are discussed in a further contribution. The clay content can be determined by real-time radiometric density measurement so that the necessary moisture or addition of fresh sand can be controlled. (orig.) With 20 figs., 9 tabs., 178 refs [de

  8. Radiometric-microbiologic assay fo vitamin B-6: analysis of plasma samples

    International Nuclear Information System (INIS)

    Guilarte, T.R.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for the analysis of vitamin B-6 in plasma was developed. The method is based on the measurement of 14CO2 generated from the metabolism of DL-l-14C-valine (L-l-14C-valine) by Kloeckera brevis. The assay is specific for the biologically active forms of the vitamin, that is, pyridoxine, pyridoxal and pyridoxamine, and their respective phosphorylated forms. The biologically inert vitamin B-6 metabolite (4-pyridoxic acid) did not generate a response at concentrations tested. The radiometric technique was shown to be sensitive to the 1 nanogram level. Reproducibility and recovery studies gave good results. Fifteen plasma samples were assayed using the radiometric and turbidimetric techniques. The correlation coefficient was r . 0.98. Turbid material or precipitated debris did not interfere with the radiometric microbiologic assay, thus allowing for simplification of assay procedure

  9. Radiometric determination in situ of the face grades in Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Smit, C.J.B.

    1985-01-01

    A prototype collimated radiometric face scanner was tested in the Harmony Gold Mine. The results obtained during the pilot study indicate that in situ radiometric uranium assays are statistically indistinguishable from those obtained conventionally from channel chip samples. In addition, the study demonstrated that reasonably reliable gold estimates can be deduced from the radiometric measurements, by use of the ratio of gold to uranium within a mine. The instrumentation, calibration procedures, and background determination are described briefly

  10. Initial Radiometric Characteristics of KOMPSAT-3A Multispectral Imagery Using the 6S Radiative Transfer Model, Well-Known Radiometric Tarps, and MFRSR Measurements

    Directory of Open Access Journals (Sweden)

    Jong-Min Yeom

    2017-02-01

    Full Text Available On-orbit radiometric characterization of the multispectral (MS imagery of the Korea Aerospace Research Institute (KARI’s Korea Multi-Purpose Satellite-3A (KOMPSAT-3A, which was launched on 25 March 2015, was conducted to provide quantitative radiometric information about KOMPSAT-3A. During the in-orbit test (IOT, vicarious radiometric calibration of KOMPSAT-3A was performed using the Second Simulation of a Satellite Signal in the Solar Spectrum (6S radiative transfer model. The characteristics of radiometric tarps, the atmospheric optical depth from multi-filter rotating shadowband radiometer (MFRSR measurements, and sun–sensor–geometry were carefully considered, in order to calculate the exact top of atmosphere (TOA radiance received by KOMPSAT-3A MS bands. In addition, the bidirectional reflectance distribution function (BRDF behaviors of the radiometric tarps were measured in the laboratory with a two-dimensional hyperspectral gonioradiometer, to compensate for the geometry discrepancy between the satellite and the ASD FieldSpec® 3 spectroradiometer. The match-up datasets between the TOA radiance and the digital number (DN from KOMPSAT-3A were used to determine DN-to-radiance conversion factors, based on linear least squares fitting for two field campaigns. The final results showed that the R2 values between the observed and simulated radiances for the blue, green, red, and near-infrared (NIR bands, are greater than 0.998. An approximate error budget analysis for the vicarious calibration of KOMPSAT-3A showed an error of less than 6.8%. When applying the laboratory-based BRDF correction to the case of higher viewing zenith angle geometry, the gain ratio was improved, particularly for the blue (1.3% and green (1.2% bands, which exhibit high sensitivity to the BRDF of radiometric tarps during the backward-scattering phase. The calculated gain ratio between the first and second campaigns showed a less than 5% discrepancy, indicating that

  11. Broadband radiometric LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  12. Comparison of digital radiometric features between radicular cysts and periapical granulomas

    International Nuclear Information System (INIS)

    Jin, Yeon Hwa; Lee, Keon Il

    1999-01-01

    The purpose of this study was to investigate whether a radiometric analysis of radicular cysts and periapical granulomas is useful in the differential diagnosis. In this experiment, twenty-nine periapical radiographs of the radicular cyst and those periapical granuloma were used. The periapical radiography was taken by intraoral paralleling device. The X-ray film was digitized and digitally filtered to reduce film-grain noise. We estimated density difference of the inner/outer area, roundness or circularity, bone profile or scan line of the margin and cumulative percentage frequency curve of radicular cyst and periapical granuloma.The obtained results were as follows ; 1. The differences in density between ROIs of inner and outer area of radicular cysts were smaller than those of periapical granulomas.2. The equivalent circular diameter was over 6.3 mm, there was significant difference between periapical cyst and periapical granuloma.3. In differential diagnosis of radicular cyst and periapical granuloma using bone profile, sensitivity, spicificity and accuracy were considerably high (0.83, 0.86, 0.86) respectively.4. Cumulative percentage frequency curve of the radicular cyst was closer to the pseudo-pixel value of 50 than average curve, whereas periapical granuloma was closer to that of 0. Hence we conclude that digital radiometric features might be useful in the differential diagnosis between radicular cyst and periapical granuloma.

  13. Comparison of digital radiometric features between radicular cysts and periapical granulomas

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Yeon Hwa; Lee, Keon Il [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Wankwang University, Yongin (Korea, Republic of)

    1999-02-15

    The purpose of this study was to investigate whether a radiometric analysis of radicular cysts and periapical granulomas is useful in the differential diagnosis. In this experiment, twenty-nine periapical radiographs of the radicular cyst and those periapical granuloma were used. The periapical radiography was taken by intraoral paralleling device. The X-ray film was digitized and digitally filtered to reduce film-grain noise. We estimated density difference of the inner/outer area, roundness or circularity, bone profile or scan line of the margin and cumulative percentage frequency curve of radicular cyst and periapical granuloma.The obtained results were as follows ; 1. The differences in density between ROIs of inner and outer area of radicular cysts were smaller than those of periapical granulomas.2. The equivalent circular diameter was over 6.3 mm, there was significant difference between periapical cyst and periapical granuloma.3. In differential diagnosis of radicular cyst and periapical granuloma using bone profile, sensitivity, spicificity and accuracy were considerably high (0.83, 0.86, 0.86) respectively.4. Cumulative percentage frequency curve of the radicular cyst was closer to the pseudo-pixel value of 50 than average curve, whereas periapical granuloma was closer to that of 0. Hence we conclude that digital radiometric features might be useful in the differential diagnosis between radicular cyst and periapical granuloma.

  14. Broadband Radiometric LED Measurements

    OpenAIRE

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(��) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irr...

  15. Radiometric and dosimetric characteristics of HgI2 detectors

    International Nuclear Information System (INIS)

    Zaletin, V.M.; Krivozubov, O.V.; Torlin, M.A.; Fomin, V.I.

    1988-01-01

    The characteristics of HgI 2 detectors in x-ray and gamma detection in applications to radiometric and dosimetric monitoring and as portable instruments for such purposes was considered. Blocks with mosaic and sandwich structures were prepared and tested against each other and, for comparative purposes, against CdTe detectors for relative sensitivities at various gamma-quanta energies. Sensitivity dependencies on gamma radiation energy were plotted for the detector materials and structures as were current dependencies on the dose rate of x rays. Results indicated that the mercury iodide detectors could be used in radiometric and dosimetric measurements at gamma quantum energies up to and in excess of 1000 KeV

  16. Radiometric weighing devices. Part 1 and 2

    International Nuclear Information System (INIS)

    Glaeser, M.

    1985-01-01

    Proceeding from the physical and mathematical fundamentals and from the types of radiometric weighing devices presently available, the radiation protection problems arising from the application of radiometric gages in industry and agriculture are discussed. Nuclear weighing devices have been found to be effective from economic point of view but in some cases gravimetric conveyor weighers are indispensable. Information and guidance is given especially for users of radiometric weighing devices. 91 refs., 69 figs., and 8 tabs

  17. Radiometric dating

    International Nuclear Information System (INIS)

    Das, N.R.

    2017-01-01

    Since the discovery of natural radioactivity in uranium, in the last decade of the nineteenth century, the nuclear property of radioactive decay of radionuclides at immutable rates has been effectively utilized in dating of varieties of naturally occurring geological matrices and the organisms which constantly replenish their "1"4C supply through respiration when alive on earth. During the period, applications of radiometric dating techniques have been extensively diversified and have enabled the geologists to indicate the absolute time scales of geological formations and the evolution of the solar system, the earth, meteorites, lunar rocks, etc. and the archaeologists to record the facts of history of several important events like dinosaur era, Iceman, the Shroud in Turin and many other ancient artefacts. In the development of dating methods, varieties of naturally occurring radio-isotopic systems with favorable half-lives ranging from about 10 years to over 100 billion years have been used as radiometric clocks. (author)

  18. Use of the radiometric method at creation cell test-systems for pre-screening of anticancer preparations

    International Nuclear Information System (INIS)

    Kuznetsova, N.N.; Khashimova, Z.S.; Sadikov, A.A.

    2004-01-01

    Full text: Development of cancer chemotherapy is tightly bound with investigation of biological activity of different compounds on in vitro test systems. Our research has been directed on definition of sensitivity of the cell line KML removed by us from passed of mice melanoma B-16. We had been investigated action of 18 clinical antineoplastic preparations of different classes: alkylating - sarcolysinum, thiophosphamide, dopan, fhthordopan; antimetabolites - cytararibinum, methotrexatum, 6-mercaptopurinum, 5-fhthorouracilum, fhthorafur; antineoplastic antibiotics- adriamycinum, neomycinum, rubomycinum, bruneomycinum, carminomycinum, olivomycinum; plant substances - vinblastinum, colchaminum (component of ointment which used at treatment of skin cancer) and other - carboplatin. Cytotoxic effect of preparations estimated two methods - radiometric on inclusion of 3H - timidine in cells and spectrophotometric by definition of total amount nucleic acids and protein. For this purpose KML cells passed in quantity of 120 thousand in 3 ml of nutrient medium RPMI 1640, 10 % calf embryo serum in bottles and after 24 hours entered substances in dozes from 0,01 up to 100 μg/ml. Contact of substances to cells was 24 hours, then 10 μ Ci 3 H - timidine was injected on bottles at 1 hour. Cells transferred on GFC-filters, washed from not connected label. Filters transferred in scintillation liquid and a level of a radio-activity determined on β-counter. All tested clinical preparations appeared active within the criteria of activity, thus the radiometric method was more sensitive, than spectrophotometric. Thus, testing results of model have shown that stable cell line KML was sensitive to action of 18 clinical preparations with various mechanisms of action by different estimations of damaging action. This model can be used for biological activity of new potential cancerolytics pre-screening. This work was supported by the Center of Science and Technology of the Republic of

  19. GEOMETRIC AND RADIOMETRIC EVALUATION OF RASAT IMAGES

    Directory of Open Access Journals (Sweden)

    A. Cam

    2016-06-01

    Full Text Available RASAT, the second remote sensing satellite of Turkey, was designed and assembled, and also is being operated by TÜBİTAK Uzay (Space Technologies Research Institute (Ankara. RASAT images in various levels are available free-of-charge via Gezgin portal for Turkish citizens. In this paper, the images in panchromatic (7.5 m GSD and RGB (15 m GSD bands in various levels were investigated with respect to its geometric and radiometric characteristics. The first geometric analysis is the estimation of the effective GSD as less than 1 pixel for radiometrically processed level (L1R of both panchromatic and RGB images. Secondly, 2D georeferencing accuracy is estimated by various non-physical transformation models (similarity, 2D affine, polynomial, affine projection, projective, DLT and GCP based RFM reaching sub-pixel accuracy using minimum 39 and maximum 52 GCPs. The radiometric characteristics are also investigated for 8 bits, estimating SNR between 21.8-42.2, and noise 0.0-3.5 for panchromatic and MS images for L1R when the sea is masked to obtain the results for land areas. The analysis show that RASAT images satisfies requirements for various applications. The research is carried out in Zonguldak test site which is mountainous and partly covered by dense forest and urban areas.

  20. Detecting payload performance based on relative radiometric characteristic: case of the optical sensors

    Science.gov (United States)

    Han, Jie; Li, Shengyang; Zhang, Tao; Qin, Bangyong

    2016-10-01

    In this paper, we propose a novel algorithm for accurately estimating the degree of radiometric non-uniformity in remote sensing images. The algorithm was tested on high-quality images and heavily striping images, and quantitative analyses were conducted to evaluate the performance for each band by measuring the radiometric non-uniformity of the images. The results demonstrated that the proposed algorithm exhibits high accuracy and stability compared with traditional algorithms. The radiometric performance of TianGong-1 short-wave infrared images was calculated using this new method, and it was highly correlated with the solar angle, pitch angle and refrigerator thermal according to the Apriori algorithm. Based on these results, we have proposed a strategy for restricting increases in striping.

  1. Off-line radiometric analysis of Planck-LFI data

    Energy Technology Data Exchange (ETDEWEB)

    Tomasi, M; Mennella, A; Bersanelli, M [Dipartimento di Fisica, Universita degli Studi di Milano, Via Celoria 16, 20133 Milano (Italy); Galeotta, S; Maris, M [LFI-DPC INAF-OATs, Via Tiepolo 11, 34131 Trieste (Italy); Lowe, S R [Jodrell Bank Centre for Astrophysics, The University of Manchester, Manchester, M13 9PL (United Kingdom); Mendes, L [Planck Science Office, European Space Agency, ESAC, P.O. box 78, 28691 Villanueva de la Canada, Madrid (Spain); Leonardi, R; Meinhold, P [Department of Physics, University of California, Santa Barbara, CA 93106-9530 (United States); Villa, F; Sandri, M; Cuttaia, F; Terenzi, L; Valenziano, L; Butler, R C [INAF-IASF Bologna, Via Gobetti, 101, 40129, Bologna (Italy); Cappellini, B [INAF-IASF Milano, Via E. Bassini 15, 20133 Milano (Italy); Gregorio, A [Department of Physics, University of Trieste, Via Valerio, 2 Trieste I-34127 (Italy); Salmon, M J [Departamento de IngenierIa de Comunicaciones, Universidad de Cantabria, Avenida de los Castros s/n. 39005 Santander (Spain); Binko, P [ISDC Data Centre for Astrophysics, University of Geneva, ch. d' Ecogia 16, 1290 Versoix (Switzerland); D' Arcangelo, O, E-mail: tomasi@lambrate.inaf.i [IFP-CNR, Via Cozzi 53, Milano (Italy)

    2009-12-15

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

  2. Off-line radiometric analysis of Planck-LFI data

    International Nuclear Information System (INIS)

    Tomasi, M; Mennella, A; Bersanelli, M; Galeotta, S; Maris, M; Lowe, S R; Mendes, L; Leonardi, R; Meinhold, P; Villa, F; Sandri, M; Cuttaia, F; Terenzi, L; Valenziano, L; Butler, R C; Cappellini, B; Gregorio, A; Salmon, M J; Binko, P; D'Arcangelo, O

    2009-01-01

    The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.

  3. KERNEL MAD ALGORITHM FOR RELATIVE RADIOMETRIC NORMALIZATION

    Directory of Open Access Journals (Sweden)

    Y. Bai

    2016-06-01

    Full Text Available The multivariate alteration detection (MAD algorithm is commonly used in relative radiometric normalization. This algorithm is based on linear canonical correlation analysis (CCA which can analyze only linear relationships among bands. Therefore, we first introduce a new version of MAD in this study based on the established method known as kernel canonical correlation analysis (KCCA. The proposed method effectively extracts the non-linear and complex relationships among variables. We then conduct relative radiometric normalization experiments on both the linear CCA and KCCA version of the MAD algorithm with the use of Landsat-8 data of Beijing, China, and Gaofen-1(GF-1 data derived from South China. Finally, we analyze the difference between the two methods. Results show that the KCCA-based MAD can be satisfactorily applied to relative radiometric normalization, this algorithm can well describe the nonlinear relationship between multi-temporal images. This work is the first attempt to apply a KCCA-based MAD algorithm to relative radiometric normalization.

  4. Solar Tower Experiments for Radiometric Calibration and Validation of Infrared Imaging Assets and Analysis Tools for Entry Aero-Heating Measurements

    Science.gov (United States)

    Splinter, Scott C.; Daryabeigi, Kamran; Horvath, Thomas J.; Mercer, David C.; Ghanbari, Cheryl M.; Ross, Martin N.; Tietjen, Alan; Schwartz, Richard J.

    2008-01-01

    The NASA Engineering and Safety Center sponsored Hypersonic Thermodynamic Infrared Measurements assessment team has a task to perform radiometric calibration and validation of land-based and airborne infrared imaging assets and tools for remote thermographic imaging. The IR assets and tools will be used for thermographic imaging of the Space Shuttle Orbiter during entry aero-heating to provide flight boundary layer transition thermography data that could be utilized for calibration and validation of empirical and theoretical aero-heating tools. A series of tests at the Sandia National Laboratories National Solar Thermal Test Facility were designed for this task where reflected solar radiation from a field of heliostats was used to heat a 4 foot by 4 foot test panel consisting of LI 900 ceramic tiles located on top of the 200 foot tall Solar Tower. The test panel provided an Orbiter-like entry temperature for the purposes of radiometric calibration and validation. The Solar Tower provided an ideal test bed for this series of radiometric calibration and validation tests because it had the potential to rapidly heat the large test panel to spatially uniform and non-uniform elevated temperatures. Also, the unsheltered-open-air environment of the Solar Tower was conducive to obtaining unobstructed radiometric data by land-based and airborne IR imaging assets. Various thermocouples installed on the test panel and an infrared imager located in close proximity to the test panel were used to obtain surface temperature measurements for evaluation and calibration of the radiometric data from the infrared imaging assets. The overall test environment, test article, test approach, and typical test results are discussed.

  5. RADIOMETRIC TECHNIQUES IN HEAVY MINERAL EXPLORATION AND EXPLOITATION

    NARCIS (Netherlands)

    DEMEIJER, RJ; TANCZOS, IC; STAPEL, C

    1994-01-01

    In recent years the Environmental Research Group of the KVI has been developing a number of radiometric techniques that may be employed in mineral sand exploration. These techniques involve: radiometric fingerprinting for assessing sand provenances and mineralogical composition; thermoluminescence

  6. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    Science.gov (United States)

    Oudrari, Hassan; McIntire, Jeff; Xiong, Xiaoxiong; Butler, James; Efremova, Boryana; Ji, Jack; Lee, Shihyan; Schwarting, Tom

    2015-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on-board the first Joint Polar Satellite System (JPSS) completed its sensor level testing on December 2014. The JPSS-1 (J1) mission is scheduled to launch in December 2016, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. VIIRS instrument was designed to provide measurements of the globe twice daily. It is a wide-swath (3,040 kilometers) cross-track scanning radiometer with spatial resolutions of 370 and 740 meters at nadir for imaging and moderate bands, respectively. It covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands [0.412 microns to 12.01 microns]. VIIRS observations are used to generate 22 environmental data products (EDRs). This paper will briefly describe J1 VIIRS characterization and calibration performance and methodologies executed during the pre-launch testing phases by the independent government team, to generate the at-launch baseline radiometric performance, and the metrics needed to populate the sensor data record (SDR) Look-Up-Tables (LUTs). This paper will also provide an assessment of the sensor pre-launch radiometric performance, such as the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field and stray light responses. A set of performance metrics generated during the pre-launch testing program will be compared to the SNPP VIIRS pre-launch performance.

  7. LFI Radiometric Chain Assembly (RCA) data handling ``Rachel''

    Science.gov (United States)

    Malaspina, M.; Franceschi, E.; Battaglia, P.; Binko, P.; Butler, R. C.; D'Arcangelo, O.; Fogliani, S.; Frailis, M.; Franceschet, C.; Galeotta, S.; Gasparo, F.; Gregorio, A.; Lapolla, M.; Leonardi, R.; Maggio, G.; Mandolesi, N.; Manzato, P.; Maris, M.; Meharga, M.; Meinhold, P.; Morisset, N.; Pasian, F.; Perrotta, F.; Rohlfs, R.; Sandri, M.; Tomasi, M.; Türler, M.; Zacchei, A.; Zonca, A.

    2009-12-01

    Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

  8. LFI Radiometric Chain Assembly (RCA) data handling 'Rachel'

    International Nuclear Information System (INIS)

    Malaspina, M; Franceschi, E; Butler, R C; Mandolesi, N; Battaglia, P; Franceschet, C; Lapolla, M; Binko, P; Meharga, M; D'Arcangelo, O; Fogliani, S; Frailis, M; Galeotta, S; Gasparo, F; Maggio, G; Manzato, P; Maris, M; Gregorio, A; Leonardi, R; Meinhold, P

    2009-01-01

    Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.

  9. Effects of agrochemicals, ultra violet stabilisers and solar radiation on the radiometric properties of greenhouse films

    Directory of Open Access Journals (Sweden)

    Giuliano Vox

    2013-10-01

    Full Text Available Agrochemicals, based on iron, sulphur and chlorine, generate by products that lead to a degradation of greenhouse films together with a decrease in their mechanical and physical properties. The degradation due to agrochemicals depends on their active principles, method and frequency of application, and greenhouse ventilation. The aim of the research was to evaluate how agrochemical contamination and solar radiation influence the radiometric properties of ethylene-vinyl acetate copolymer greenhouse films by means of laboratory and field tests. The films, manufactured on purpose with the addition of different light stabiliser systems, were exposed to natural outdoor weathering at the experimental farm of the University of Bari (Italy; 41° 05’ N in the period from 2006 to 2008. Each film was tested for two low tunnels: one low tunnel was sprayed from inside with the agrochemicals containing iron, chlorine and sulphur while the other one was not sprayed and served as control. Radiometric laboratory tests were carried out on the new films and on samples taken at the end of the trials. The experimental tests showed that both the natural weathering together with the agrochemicals did not modify significantly the radiometric properties of the films in the solar and in the photosynthetically active radiation wavelength range. Within six months of experimental field tests the variations in these radiometric characteristics were at most 10%. Significant variations, up to 70% of the initial value, were recorded for the stabilised films in the long-wave infrared radiation wavelength range.

  10. Evaluation of a radiometric method for studying bacterial activity in the presence of antimicrobial agents

    Energy Technology Data Exchange (ETDEWEB)

    Cutler, R.R.; Wilson, P.; Clarke, F.V. (Newham District Microbiology Labs., St. Andrews Hospital, London (UK))

    1989-06-01

    In a study involving 2760 tests, the BACTEC semi-automatic radiometric method which measures bacterial metabolic activity and produces a BACTEC growth index, was compared with two conventional methods commonly used for determining growth, absorbance and viable counts. In 92% of radiometry tests the suppression of growth was inversely related to the antibiotic concentration. This compared with 83% for absorbance and 63% for viable counts. The radiometric method was found to be more rapid, easier to use and more reproducible in determining the effect of antibiotics on the activity of bacteria than viable counting or absorbance methods. (author).

  11. Evaluation of a radiometric method for studying bacterial activity in the presence of antimicrobial agents

    International Nuclear Information System (INIS)

    Cutler, R.R.; Wilson, P.; Clarke, F.V.

    1989-01-01

    In a study involving 2760 tests, the BACTEC semi-automatic radiometric method which measures bacterial metabolic activity and produces a BACTEC growth index, was compared with two conventional methods commonly used for determining growth, absorbance and viable counts. In 92% of radiometry tests the suppression of growth was inversely related to the antibiotic concentration. This compared with 83% for absorbance and 63% for viable counts. The radiometric method was found to be more rapid, easier to use and more reproducible in determining the effect of antibiotics on the activity of bacteria than viable counting or absorbance methods. (author)

  12. Tasmanian tin and tungsten granites - their radiometric characteristics

    International Nuclear Information System (INIS)

    Yeates, A.N.

    1982-01-01

    A radiometric survey of Tasmanian granites has shown, with one exception, that tin and tungsten-bearing granites have high radioactivity, largely owing to increased uranium. Many have a high uranium/thorium ratio as well. Radiometric measurements can also delineate different granite types within composite bodies

  13. Training course on radiometric prospecting techniques

    International Nuclear Information System (INIS)

    1979-01-01

    A training course on radiometric prospecting techniques was presented by the Atomic Energy Board in collaboration with the South African Geophysical Association and the Geological Society of South Africa. Various aspects related to uranium prospecting were discussed e.g. the uranium supply and demand position, the basic physics of radioactivity, uranium geochemistry, mineralogy and mobility, the instrumentation and techniques used in uranium exploration, for example, borehole logging, radon emanometry and airborne radiometric surveys and also data processing and interpretation methods

  14. RapidEye constellation relative radiometric accuracy measurement using lunar images

    Science.gov (United States)

    Steyn, Joe; Tyc, George; Beckett, Keith; Hashida, Yoshi

    2009-09-01

    The RapidEye constellation includes five identical satellites in Low Earth Orbit (LEO). Each satellite has a 5-band (blue, green, red, red-edge and near infrared (NIR)) multispectral imager at 6.5m GSD. A three-axes attitude control system allows pointing the imager of each satellite at the Moon during lunations. It is therefore possible to image the Moon from near identical viewing geometry within a span of 80 minutes with each one of the imagers. Comparing the radiometrically corrected images obtained from each band and each satellite allows a near instantaneous relative radiometric accuracy measurement and determination of relative gain changes between the five imagers. A more traditional terrestrial vicarious radiometric calibration program has also been completed by MDA on RapidEye. The two components of this program provide for spatial radiometric calibration ensuring that detector-to-detector response remains flat, while a temporal radiometric calibration approach has accumulated images of specific dry dessert calibration sites. These images are used to measure the constellation relative radiometric response and make on-ground gain and offset adjustments in order to maintain the relative accuracy of the constellation within +/-2.5%. A quantitative comparison between the gain changes measured by the lunar method and the terrestrial temporal radiometric calibration method is performed and will be presented.

  15. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  16. Determination of molybdenite leaching degree by x-ray radiometric analysis

    International Nuclear Information System (INIS)

    Bibinov, S.A.; Gladyshev, V.P.; Yarmolik, A.S.; Kim, A.Ch.; Sokur, N.P.

    1984-01-01

    A express chemical X-ray radiometric method for determination of leaching degree and analysis of molybdenite products is developed. The method comprises chemical preparation and the following X-ray radiometric determination of molyb bdenum. Total duration of the analysis is 1-1.5 h. The best reproductivity is btained at X-ray radiometric analysis as compared with the chemical one

  17. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    CERN Document Server

    Beard, L P

    2000-01-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  18. Data acquisition and processing - helicopter radiometric survey, Krageroe, 1998

    Energy Technology Data Exchange (ETDEWEB)

    Beard, Les P.; Mogaard, John Olav

    2000-07-01

    On 07 October 1998 a helicopter radiometric survey was flown in the vicinity of Krageroe municipality. The purpose of the survey was to provide radiometric information to help assess radon hazard from radioactive rocks in the area. A total of 60 line-kilometres of radiometric data were acquired in a single flight, covering an area of approximately 3 square km with a 50-m line spacing. The data were collected by Geological Survey of Norway (NGU) personnel and processed at NGU. Radiometric data were reduced using the three-channel procedure recommended by the International Atomic Energy Association. All data were gridded using square cells with 30-m sides and geophysical maps were produced at a scale of 1:5000. This report covers aspects of data acquisition and processing (Author)

  19. Empirical Radiometric Normalization of Road Points from Terrestrial Mobile Lidar System

    Directory of Open Access Journals (Sweden)

    Tee-Ann Teo

    2015-05-01

    Full Text Available Lidar data provide both geometric and radiometric information. Radiometric information is influenced by sensor and target factors and should be calibrated to obtain consistent energy responses. The radiometric correction of airborne lidar system (ALS converts the amplitude into a backscatter cross-section with physical meaning value by applying a model-driven approach. The radiometric correction of terrestrial mobile lidar system (MLS is a challenging task because it does not completely follow the inverse square range function at near-range. This study proposed a radiometric normalization workflow for MLS using a data-driven approach. The scope of this study is to normalize amplitude of road points for road surface classification, assuming that road points from different scanners or strips should have similar responses in overlapped areas. The normalization parameters for range effect were obtained from crossroads. The experiment showed that the amplitude difference between scanners and strips decreased after radiometric normalization and improved the accuracy of road surface classification.

  20. Radiometric analyzer

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring the characteristic values of a sample by radiation includes a humer of radiation measuring subsystems having different ratios of sensitivities to the elements of the sample and linearizing circuits having inverse function characteristics of calibration functions which correspond to the radiation measuring subsystems. A weighing adder operates a desirable linear combination of the outputs of the linearizing circuits. Operators for operating between two or more different linear combinations are included

  1. Radiometric well logging instruments

    International Nuclear Information System (INIS)

    Davydov, A.V.

    1975-01-01

    The technical properties of well instruments for radioactive logging used in the radiometric logging complexes PKS-1000-1 (''Sond-1'') and PRKS-2 (''Vitok-2'') are described. The main features of the electric circuit of the measuring channels are given

  2. Radiometric Correction of Multitemporal Hyperspectral Uas Image Mosaics of Seedling Stands

    Science.gov (United States)

    Markelin, L.; Honkavaara, E.; Näsi, R.; Viljanen, N.; Rosnell, T.; Hakala, T.; Vastaranta, M.; Koivisto, T.; Holopainen, M.

    2017-10-01

    Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  3. RADIOMETRIC CORRECTION OF MULTITEMPORAL HYPERSPECTRAL UAS IMAGE MOSAICS OF SEEDLING STANDS

    Directory of Open Access Journals (Sweden)

    L. Markelin

    2017-10-01

    Full Text Available Novel miniaturized multi- and hyperspectral imaging sensors on board of unmanned aerial vehicles have recently shown great potential in various environmental monitoring and measuring tasks such as precision agriculture and forest management. These systems can be used to collect dense 3D point clouds and spectral information over small areas such as single forest stands or sample plots. Accurate radiometric processing and atmospheric correction is required when data sets from different dates and sensors, collected in varying illumination conditions, are combined. Performance of novel radiometric block adjustment method, developed at Finnish Geospatial Research Institute, is evaluated with multitemporal hyperspectral data set of seedling stands collected during spring and summer 2016. Illumination conditions during campaigns varied from bright to overcast. We use two different methods to produce homogenous image mosaics and hyperspectral point clouds: image-wise relative correction and image-wise relative correction with BRDF. Radiometric datasets are converted to reflectance using reference panels and changes in reflectance spectra is analysed. Tested methods improved image mosaic homogeneity by 5 % to 25 %. Results show that the evaluated method can produce consistent reflectance mosaics and reflectance spectra shape between different areas and dates.

  4. The radiometric industries of the countries of the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt

    1975-01-01

    The economic development of the radiometric industries in the EEC and the USA since 1960 is studied on the basis of sales statistics. The study covers the supply and the use of radioisotopes, the application of radiometric techniques, the scope and the development of the foreign trade as well as the structure of the firms concerned. The future need for radiometric apparatus is estimated as regards radiation protection, laboratories, industry, nuclear power plants and medicine

  5. Automated radiometric detection of bacteria

    International Nuclear Information System (INIS)

    Waters, J.R.

    1974-01-01

    A new radiometric method called BACTEC, used for the detection of bacteria in cultures or in supposedly sterile samples, was discussed from the standpoint of methodology, both automated and semi-automated. Some of the results obtained so far were reported and some future applications and development possibilities were described. In this new method, the test sample is incubated in a sealed vial with a liquid culture medium containing a 14 C-labeled substrate. If bacteria are present, they break down the substrate, producing 14 CO 2 which is periodically extracted from the vial as a gas and is tested for radioactivity. If this gaseous radioactivity exceeds a threshold level, it is evidence of bacterial presence and growth in the test vial. The first application was for the detection of bacteria in the blood cultures of hospital patients. Data were presented showing typical results. Also discussed were future applications, such as rapid screening for bacteria in urine industrial sterility testing and the disposal of used 14 C substrates. (Mukohata, S.)

  6. Radiometric report for a blast furnace tracing with radioactive isotopes

    International Nuclear Information System (INIS)

    Tanase, G.; Tanase, M.

    1995-01-01

    One of the methods to monitor refractory wall of blast furnace is its tracing with radioactive isotopes. The tracer isotope can be detected by two ways: the external dosimetric measurement at the armour of the blast furnace and/or the radiometric measurement of the iron sample charge by charge. Any change in radiometric situation of tracer radioisotope is recorded in a radiometric report. This paper presents an original concept of radiometric report based upon PARADOX and CORELDRAW soft kits. Their advantage are: quick and easy changes, easy recording of current radioactivity of tracer isotope, short history of changes, visual mapping of the tracer isotope and others. In this way we monitored 6 blast furnaces and more than 180 radioactive sources

  7. Radiometric detection of yeasts in blood cultures of cancer patients

    International Nuclear Information System (INIS)

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-01-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts

  8. RADIOMETRIC CALIBRATION OF AIRBORNE LASER SCANNING DATA

    OpenAIRE

    Pilarska Magdalena

    2016-01-01

    Airborne laser scanning (ALS) is widely used passive remote sensing technique. The radiometric calibration of ALS data is presented in this article. This process is a necessary element in data processing since it eliminates the influence of the external factors on the obtained values of radiometric features such as range and incidence angle. The datasets were captured with three different laser scanners; since each of these operates at a different wavelength (532, 106 4 and 1550 nm) th...

  9. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    Science.gov (United States)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  10. Radiometric Correction of Close-Range Spectral Image Blocks Captured Using an Unmanned Aerial Vehicle with a Radiometric Block Adjustment

    Directory of Open Access Journals (Sweden)

    Eija Honkavaara

    2018-02-01

    Full Text Available Unmanned airborne vehicles (UAV equipped with novel, miniaturized, 2D frame format hyper- and multispectral cameras make it possible to conduct remote sensing measurements cost-efficiently, with greater accuracy and detail. In the mapping process, the area of interest is covered by multiple, overlapping, small-format 2D images, which provide redundant information about the object. Radiometric correction of spectral image data is important for eliminating any external disturbance from the captured data. Corrections should include sensor, atmosphere and view/illumination geometry (bidirectional reflectance distribution function—BRDF related disturbances. An additional complication is that UAV remote sensing campaigns are often carried out under difficult conditions, with varying illumination conditions and cloudiness. We have developed a global optimization approach for the radiometric correction of UAV image blocks, a radiometric block adjustment. The objective of this study was to implement and assess a combined adjustment approach, including comprehensive consideration of weighting of various observations. An empirical study was carried out using imagery captured using a hyperspectral 2D frame format camera of winter wheat crops. The dataset included four separate flights captured during a 2.5 h time period under sunny weather conditions. As outputs, we calculated orthophoto mosaics using the most nadir images and sampled multiple-view hyperspectral spectra for vegetation sample points utilizing multiple images in the dataset. The method provided an automated tool for radiometric correction, compensating for efficiently radiometric disturbances in the images. The global homogeneity factor improved from 12–16% to 4–6% with the corrections, and a reduction in disturbances could be observed in the spectra of the object points sampled from multiple overlapping images. Residuals in the grey and white reflectance panels were less than 5% of the

  11. Study of the use of a Phoswich detector for aerial radiometric surveys

    International Nuclear Information System (INIS)

    Schneid, E.J.; Lagin, L.J.

    1981-09-01

    Large volume, actively shielded Phoswich detector configurations were investigated for application in airborne radiometric survey systems in order to increase the sensitivity to ground-level potassium, uranium, and thorium compared to conventional NaI detectors of similar sizes. One Phoswich configuration was fabricated and flight tested. The flight measurements with the Phoswich detector and a conventional NaI detector utilized the Bendix Field Engineering Corporation - US Department of Energy/Grand Junction Office Walker Field Aerial Radiometric Survey Calibration Facility, the DOE dynamic test range, and a region in the southwest portion of the Lubbock, Texas, Quadrangle. The tests demonstrated that the Phoswich detector can function in an operational environment and does provide greater sensitivity to ground-level potassium, uranium, and thorium concentration than the conventional NaI detector. The multicrystal configuration for the Phoswich detector provided the capability to simultaneously measure the atmospheric radon background without the need of heavy lead shields. The flight tests indicated that the Phoswich detector has directional discrimination capability not available with conventional NaI detector systems. This directional capability can be used to distinguish the location, relative to the aircraft, of localized strong sources of radiation

  12. Panay carborne radiometric and geochemical surveys

    International Nuclear Information System (INIS)

    Santos, G. Jr.

    1981-09-01

    A carborne radiometric survey and stream sediments collection were conducted in Panay and Guimaras Islands. An area in Nabas, Aklan, situated in the northwestern tip of Panay (Buruanga Peninsula) which indicated 2 to 3 times above background radioactivity was delineated. Uranium content in the stream sediment samples collected from Buruanga Peninsula was generally higher than those obtained in other parts of the island. Radioactivity measurements and uranium content in stream sediments were found to be within background levels. It is recommended that follow-up radiometric and geochemical surveys be undertaken in Buruanga Peninsula and additional stream sediments samples be collected in Panay to achieve better sampling density and coverage. (author)

  13. A simple radiometric in vitro assay for acetylcholinesterase inhibitors

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Burns, H.D.; Dannals, R.F.; Wagner, H.N. Jr.

    1983-01-01

    A radiometric method for screening acetylcholinesterase inhibitors has been described. The method is based on the production of [ 14 C]carbon dioxide from the hydrolysis of acetylcholine. The inhibitory concentration at 50% (IC50) values for several known acetylcholinesterase inhibitors were in agreement with literature values. The new radiometric method is simple, inexpensive, and has the potential for automation

  14. Laboratory-Based BRDF Calibration of Radiometric Tarps

    Science.gov (United States)

    Georgiev, Georgi T.; Butler, James J.

    2007-01-01

    The current study provides the remote sensing community with important high accuracy laboratory-based BRDF calibration of radiometric tarps. The results illustrate the dependence of tarps' weft and warp threads orientation on BRDF. The study was done at incident angles of 0deg, 10deg, and 30deg; scatter zenith angles from 0deg to 60deg, and scatter azimuth angles of 0deg, 45deg, 90deg, 135deg, and 180deg. The wavelengths were 485nm, 550nm, 633nm and 800nm. The dependence is well defined at all measurement geometries and wavelengths. It can be as high as 8% at 0deg incident angle and 2% at 30deg incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps is reported. The backward scatter is well pronounced for the white samples. The black sample has well pronounced forward scatter. The BRDF characterization of radiometric tarps can be successfully extended to other structured surface fabric samples. The results are NIST traceable.

  15. Radiometric characterization of Landsat Collection 1 products

    Science.gov (United States)

    Micijevic, Esad; Haque, Md. Obaidul; Mishra, Nischal

    2017-09-01

    Landsat data in the U.S. Geological Survey (USGS) archive are being reprocessed to generate a tiered collection of consistently geolocated and radiometrically calibrated products that are suitable for time series analyses. With the implementation of the collection management, no major updates will be made to calibration of the Landsat sensors within a collection. Only calibration parameters needed to maintain the established calibration trends without an effect on derived environmental records will be regularly updated, while all other changes will be deferred to a new collection. This first collection, Collection 1, incorporates various radiometric calibration updates to all Landsat sensors including absolute and relative gains for Landsat 8 Operational Land Imager (OLI), stray light correction for Landsat 8 Thermal Infrared Sensor (TIRS), absolute gains for Landsat 4 and 5 Thematic Mappers (TM), recalibration of Landsat 1-5 Multispectral Scanners (MSS) to ensure radiometric consistency among different formats of archived MSS data, and a transfer of Landsat 8 OLI reflectance based calibration to all previous Landsat sensors. While all OLI/TIRS, ETM+ and majority of TM data have already been reprocessed to Collection 1, a completion of MSS and remaining TM data reprocessing is expected by the end of this year. It is important to note that, although still available for download from the USGS web pages, the products generated using the Pre-Collection processing do not benefit from the latest radiometric calibration updates. In this paper, we are assessing radiometry of solar reflective bands in Landsat Collection 1 products through analysis of trends in on-board calibrator and pseudo invariant site (PICS) responses.

  16. Complex optimization of radiometric control and measurement systems

    International Nuclear Information System (INIS)

    Onishchenko, A.M.

    1995-01-01

    Fundamentals of a new approach to increase in the accuracy of radiometric systems of control and measurements are presented in succession. Block diagram of the new concept of radiometric system optimization is provided. The approach involving radical increase in accuracy and envisages ascertaining of controlled parameter by the totality of two intelligence signals closely correlated with each other. The new concept makes use of system analysis as a unified one-piece object, permitting euristic synthesis of the system. 4 refs., 3 figs

  17. English/Russian terminology on radiometric calibration of space-borne optoelectronic sensors

    Science.gov (United States)

    Privalsky, V.; Zakharenkov, V.; Humpherys, T.; Sapritsky, V.; Datla, R.

    The efficient use of data acquired through exo-atmospheric observations of the Earth within the framework of existing and newly planned programs requires a unique understanding of respective terms and definitions. Yet, the last large-scale document on the subject - The International Electrotechnical Vocabulary - had been published 18 years ago. This lack of a proper document, which would reflect the changes that had occurred in the area since that time, is especially detrimental to the developing international efforts aimed at global observations of the Earth from space such as the Global Earth Observations Program proposed by the U.S.A. at the 2003 WMO Congress. To cover this gap at least partially, a bi-lingual explanatory dictionary of terms and definitions in the area of radiometric calibration of space-borne IR sensors is developed. The objectives are to produce a uniform terminology for the global space-borne observations of the Earth, establish a unique understanding of terms and definitions by the radiometric communities, including a correspondence between the Russian and American terms and definitions, and to develop a formal English/Russian reference dictionary for use by scientists and engineers involved in radiometric observations of the Earth from space. The dictionary includes close to 400 items covering basic concepts of geometric, wave and corpuscular optics, remote sensing technologies, and ground-based calibration as well as more detailed treatment of terms and definitions in the areas of radiometric quantities, symbols and units, optical phenomena and optical properties of objects and media, and radiometric systems and their properties. The dictionary contains six chapters: Basic Concepts, Quantities, Symbols, and Units, Optical phenomena, Optical characteristics of surfaces and media, Components of Radiometric Systems, Characteristics of radiometric system components, plus English/Russian and Russian/Inglish indices.

  18. Evaluation of relative radiometric correction techniques on Landsat 8 OLI sensor data

    Science.gov (United States)

    Novelli, Antonio; Caradonna, Grazia; Tarantino, Eufemia

    2016-08-01

    The quality of information derived from processed remotely sensed data may depend upon many factors, mostly related to the extent data acquisition is influenced by atmospheric conditions, topographic effects, sun angle and so on. The goal of radiometric corrections is to reduce such effects in order enhance the performance of change detection analysis. There are two approaches to radiometric correction: absolute and relative calibrations. Due to the large amount of free data products available, absolute radiometric calibration techniques may be time consuming and financially expensive because of the necessary inputs for absolute calibration models (often these data are not available and can be difficult to obtain). The relative approach to radiometric correction, known as relative radiometric normalization, is preferred with some research topics because no in situ ancillary data, at the time of satellite overpasses, are required. In this study we evaluated three well known relative radiometric correction techniques using two Landsat 8 - OLI scenes over a subset area of the Apulia Region (southern Italy): the IR-MAD (Iteratively Reweighted Multivariate Alteration Detection), the HM (Histogram Matching) and the DOS (Dark Object Subtraction). IR-MAD results were statistically assessed within a territory with an extremely heterogeneous landscape and all computations performed in a Matlab environment. The panchromatic and thermal bands were excluded from the comparisons.

  19. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  20. Automated gamma spectrometry and data analysis on radiometric neutron dosimeters

    International Nuclear Information System (INIS)

    Matsumoto, W.Y.

    1983-01-01

    An automated gamma-ray spectrometry system was designed and implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Laboratory (HEDL) to analyze radiometric neutron dosimeters. Unattended, automatic, 24 hour/day, 7 day/week operation with online data analysis and mainframe-computer compatible magnetic tape output are system features. The system was used to analyze most of the 4000-plus radiometric monitors (RM's) from extensive reactor characterization tests during startup and initial operation of th Fast Flux Test Facility (FFTF). The FFTF, operated by HEDL for the Department of Energy, incorporates a 400 MW(th) sodium-cooled fast reactor. Aumomated system hardware consists of a high purity germanium detector, a computerized multichannel analyzer data acquisition system (Nuclear Data, Inc. Model 6620) with two dual 2.5 Mbyte magnetic disk drives plus two 10.5 inch reel magnetic tape units for mass storage of programs/data and an automated Sample Changer-Positioner (ASC-P) run with a programmable controller. The ASC-P has a 200 sample capacity and 12 calibrated counting (analysis) positions ranging from 6 inches (15 cm) to more than 20 feet (6.1 m) from the detector. The system software was programmed in Fortran at HEDL, except for the Nuclear Data, Inc. Peak Search and Analysis Program and Disk Operating System (MIDAS+)

  1. Map of natural gamma radiation in Spain: radiometric characterization of different types of surfaces

    International Nuclear Information System (INIS)

    Suarez Mahou, E.; Fernandez Amigot, J.A.; Botas Medina, J.

    1997-01-01

    The gamma radioactivity flowing from ground and rocks is due to the presence in these of uranium, thorium and potassium-40. The method of radiometric characterization depends on the purpose of the undertaking. Radiometric characterization can be realized on big surfaces (tens or hundreds of square kilometres studied on a national scale), medium size surfaces (50 to 1000 square kilometres, for example, in epidemiological or biological studies in areas with a determined radiometric background) small surfaces of less than 50 square kilometres (industrial sites, pre-operational studies, etc.). This article considers aspects of radiometric characterization on surfaces of interest and describes the contribution of the MARNA (Natural Provisional Radiation Map of Spain) Project selection and radiometric characterization

  2. Radiometric study of creep in ingot rolling

    International Nuclear Information System (INIS)

    Kubicek, P.; Zamyslovsky, Z.; Uherek, J.

    The radiometric study of creep during ingot rolling performed in the rolling mill of the Vitkovice Iron and Steel Works and the first results are described. Selected sites in 3 to 8 ton ingots were labelled with 2 to 3.7x10 5 Bq of 60 Co and after rolling into blocks, the transposition of the labelled sites of the ingots was investigated. The results indicate creep during rolling, local extension in certain sites under study and help to determine the inevitable bottom crop incurred in the forming. Finally, the requirements put on the radiometric apparatus for the next stages of technological research are presented. (author)

  3. Rapid detection and identification of pathogenic mycobacteria by combining radiometric and nucleic acid probe methods

    International Nuclear Information System (INIS)

    Ellner, P.D.; Kiehn, T.E.; Cammarata, R.; Hosmer, M.

    1988-01-01

    The combination of radiometric methodology (BACTEC 12B) and probe technology for recovery and identification of mycobacteria was studied in two large hospital laboratories. The sediment from vials with positive growth indices was tested with DNA probes specific for Mycobacterium tuberculosis, Mycobacterium avium, and Mycobacterium intracellulare. The sensitivity of the radiometric method and the specificity of the probes resulted in a marked reduction in the time to the final report. Biochemical testing could be eliminated on isolates giving a positive reaction with one of the probes. Some 176 isolates of M. tuberculosis, 110 of M. avium, and 5 of M. intracellulare were recovered. Two-thirds of these isolates were detected and identified within 2 weeks of inoculation and the remainder was detected by 4 weeks, a reduction of 5 to 7 weeks to the final report

  4. Laboratory-based bidirectional reflectance distribution functions of radiometric tarps

    International Nuclear Information System (INIS)

    Georgiev, Georgi T.; Butler, James J.

    2008-01-01

    Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 deg., 10 deg., and 30 deg.; scatter zenith angles from 0 deg. to 60 deg.; and scatter azimuth angles of 0 deg., 45 deg., 90 deg., 135 deg., and 180 deg.. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 deg. incident angle and 12% at 30 deg. incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable

  5. Laboratory-based bidirectional reflectance distribution functions of radiometric tarps.

    Science.gov (United States)

    Georgiev, Georgi T; Butler, James J

    2008-06-20

    Laboratory-based bidirectional reflectance distribution functions (BRDFs) of radiometric tarp samples used in the vicarious calibration of Earth remote sensing satellite instruments are presented in this paper. The results illustrate the BRDF dependence on the orientation of the tarps' weft and warp threads. The study was performed using the GSFC scatterometer at incident zenith angles of 0 degrees, 10 degrees, and 30 degrees; scatter zenith angles from 0 degrees to 60 degrees; and scatter azimuth angles of 0 degrees, 45 degrees, 90 degrees, 135 degrees, and 180 degrees. The wavelengths were 485 nm, 550 nm, 633 nm, and 800 nm. The tarp's weft and warp dependence on BRDF is well defined at all measurement geometries and wavelengths. The BRDF difference can be as high as 8% at 0 degrees incident angle and 12% at 30 degrees incident angle. The fitted BRDF data show a very small discrepancy from the measured ones. New data on the forward and backscatter properties of radiometric tarps are reported. The backward scatter is well pronounced for the white samples. The black sample has well-pronounced forward scatter. The provided BRDF characterization of radiometric tarps is an excellent reference for anyone interested in using tarps for radiometric calibrations. The results are NIST traceable.

  6. Field radiometric methods of prospecting and exploration for uranium ores

    International Nuclear Information System (INIS)

    Gorbushina, L.V.; Savenko, E.I.; Serdyukova, A.S.

    1978-01-01

    The textbook includes two main chapters which describe gamma- and emanation field radiometric methods. The textbook is intended for geology and geophysics students having training practice in field radiometric methods and is additional to the course of lectures. The textbook can be used in the''Radiometry'' course which is studied in appropriate geological and technical colleges

  7. Determining total sulfur content in coal by MSC radiometric sulfur meter

    Energy Technology Data Exchange (ETDEWEB)

    Czerw, B; Sikora, T; Golebiowski, W

    1976-01-01

    The MSC radiometric sulfur meter is used to determine total sulfur content in brown and black coals. Sulfur content is determined by measuring intensity of radiation beam which has travelled through a coal sample with the optimum constant surface mass. Construction of the MSC, consisting of a measuring head and the electronic measuring system, is shown in a scheme. AM-241 (with activity of 50 mCi) is the source of radiation. Energy of 25.3 keV (tin disc) is selected as the optimum. The SSU-70 probe with NaJ/Tl crystal is the radiation detector. The black coal sample weighs 10 g and the brown coal sample weighs 18 g. Duration of sulfur determination is 10 min. Error of sulfur determination ranges from plus or minus 0.2% to 0.3%. The results of operational tests of MSC radiometric sulfur meters in black and brown coal mines are discussed. Accuracy of measurement is shown in 5 tables. (8 refs.)

  8. Itinerant radiometric laboratory (IRL-76)

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Domaratskij, V.P.; Kostikov, Yu.I.

    1978-01-01

    A mobile radiometric laboratory for routine radiation monitoring of the environment, personnel, and population is described. As compared to the previous models, this one incorporates a number of new features and is more informative and versatile. The design and main technical and operating characteristics of the laboratory are detailed

  9. Radiometric determination of monoethanolamine with 65ZnSo4

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with 65 Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. (author)

  10. Characterization of Mycobacterium paratuberculosis by gas-liquid and thin-layer chromatography and rapid demonstration of mycobactin dependence using radiometric methods

    International Nuclear Information System (INIS)

    Damato, J.J.; Knisley, C.; Collins, M.T.

    1987-01-01

    Thirty-six Mycobacterium paratuberculosis isolates of bovine, caprine, and ovine origins were evaluated by using gas-liquid chromatography (GLC), thin-layer chromatography (TLC), and BACTEC 7H12 Middlebrook TB medium in an effort to more rapidly differentiate this group of organisms from other mycobacteria. Bacterial suspensions (0.1 ml) were inoculated by syringe into 7H12 broth containing 2 micrograms of mycobactin P per ml and control broth without mycobactin P. Cultures were incubated at 37 0 C and read daily with a BACTEC Model 301. After 8 days of incubation, the growth index readings for the test broths containing mycobactin P were twice those of the control broths without mycobactin P. Sixty-five isolates of mycobacteria other than M. paratuberculosis were also examined. No difference was noted between the growth index readings of control and mycobactin-containing broths. Except for Mycobacterium avium-Mycobacterium intracellulare, TLC studies differentiated M. paratuberculosis from the other mycobacterial species tested. The GLC data reveal that all M. paratuberculosis isolates had a distinctive peak (14A) which was not found among M. avium-M. intracellulare complex organisms. These data indicate that 7H12 radiometric broth was able to rapidly demonstrate the mycobactin dependence of M. paratuberculosis and GLC and TLC procedures were capable of rapidly differentiating this organism from the other mycobacteria studied

  11. A COMPARISON OF LIDAR REFLECTANCE AND RADIOMETRICALLY CALIBRATED HYPERSPECTRAL IMAGERY

    Directory of Open Access Journals (Sweden)

    A. Roncat

    2016-06-01

    Full Text Available In order to retrieve results comparable under different flight parameters and among different flight campaigns, passive remote sensing data such as hyperspectral imagery need to undergo a radiometric calibration. While this calibration, aiming at the derivation of physically meaningful surface attributes such as a reflectance value, is quite cumbersome for passively sensed data and relies on a number of external parameters, the situation is by far less complicated for active remote sensing techniques such as lidar. This fact motivates the investigation of the suitability of full-waveform lidar as a “single-wavelength reflectometer” to support radiometric calibration of hyperspectral imagery. In this paper, this suitability was investigated by means of an airborne hyperspectral imagery campaign and an airborne lidar campaign recorded over the same area. Criteria are given to assess diffuse reflectance behaviour; the distribution of reflectance derived by the two techniques were found comparable in four test areas where these criteria were met. This is a promising result especially in the context of current developments of multi-spectral lidar systems.

  12. Ash content of lignites - radiometric analysis

    International Nuclear Information System (INIS)

    Leonhardt, J.; Thuemmel, H.W.

    1986-01-01

    The quality of lignites is governed by the ash content varying in dependence upon the geologic conditions. Setup and function of the radiometric devices being used for ash content analysis in the GDR are briefly described

  13. RADIOMETRIC NORMALIZATION OF LARGE AIRBORNE IMAGE DATA SETS ACQUIRED BY DIFFERENT SENSOR TYPES

    Directory of Open Access Journals (Sweden)

    S. Gehrke

    2016-06-01

    Full Text Available Generating seamless mosaics of aerial images is a particularly challenging task when the mosaic comprises a large number of im-ages, collected over longer periods of time and with different sensors under varying imaging conditions. Such large mosaics typically consist of very heterogeneous image data, both spatially (different terrain types and atmosphere and temporally (unstable atmo-spheric properties and even changes in land coverage. We present a new radiometric normalization or, respectively, radiometric aerial triangulation approach that takes advantage of our knowledge about each sensor’s properties. The current implementation supports medium and large format airborne imaging sensors of the Leica Geosystems family, namely the ADS line-scanner as well as DMC and RCD frame sensors. A hierarchical modelling – with parameters for the overall mosaic, the sensor type, different flight sessions, strips and individual images – allows for adaptation to each sensor’s geometric and radiometric properties. Additional parameters at different hierarchy levels can compensate radiome-tric differences of various origins to compensate for shortcomings of the preceding radiometric sensor calibration as well as BRDF and atmospheric corrections. The final, relative normalization is based on radiometric tie points in overlapping images, absolute radiometric control points and image statistics. It is computed in a global least squares adjustment for the entire mosaic by altering each image’s histogram using a location-dependent mathematical model. This model involves contrast and brightness corrections at radiometric fix points with bilinear interpolation for corrections in-between. The distribution of the radiometry fixes is adaptive to each image and generally increases with image size, hence enabling optimal local adaptation even for very long image strips as typi-cally captured by a line-scanner sensor. The normalization approach is implemented in

  14. Sensitive radiometric assay for enkephalin convertase and other carboxypeptidase B-like enzymes

    International Nuclear Information System (INIS)

    Stack, G.; Fricker, L.D.; Snyder, S.H.

    1984-01-01

    A sensitive radiometric assay for carboxypeptidase B-like enzymes has been developed using enkephalin convertase, an enkephalin synthesizing carboxypeptidase. The assay is based on the differential solubility of 3 H-labeled substrate and product in chloroform. The substrates 3 H-benzoyl-Phe-Ala-Arg or 3 H-benzoyl-Phe-Leu-Arg are poorly soluble in chloroform due to the charged arginine. The products of carboxypeptidase B-like activity on these substrates, 3 H-benzoyl-Phe-Ala or 3 H-benzoyl Phe-Leu partition quantitatively into chloroform, allowing rapid separation of product from substrate. This assay is approximately 100 times more sensitive than a similar fluorometric assay utilizing dansyl-Phe-Ala-Arg as a substrate

  15. Sensitive radiometric assay for enkephalin convertase and other carboxypeptidase B-like enzymes

    Energy Technology Data Exchange (ETDEWEB)

    Stack, G.; Fricker, L.D.; Snyder, S.H.

    1984-01-09

    A sensitive radiometric assay for carboxypeptidase B-like enzymes has been developed using enkephalin convertase, an enkephalin synthesizing carboxypeptidase. The assay is based on the differential solubility of /sup 3/H-labeled substrate and product in chloroform. The substrates /sup 3/H-benzoyl-Phe-Ala-Arg or /sup 3/H-benzoyl-Phe-Leu-Arg are poorly soluble in chloroform due to the charged arginine. The products of carboxypeptidase B-like activity on these substrates, /sup 3/H-benzoyl-Phe-Ala or /sup 3/H-benzoyl Phe-Leu partition quantitatively into chloroform, allowing rapid separation of product from substrate. This assay is approximately 100 times more sensitive than a similar fluorometric assay utilizing dansyl-Phe-Ala-Arg as a substrate.

  16. A new radiometric unit of measure to characterize SWIR illumination

    Science.gov (United States)

    Richards, A.; Hübner, M.

    2017-05-01

    We propose a new radiometric unit of measure we call the `swux' to unambiguously characterize scene illumination in the SWIR spectral band between 0.8μm-1.8μm, where most of the ever-increasing numbers of deployed SWIR cameras (based on standard InGaAs focal plane arrays) are sensitive. Both military and surveillance applications in the SWIR currently suffer from a lack of a standardized SWIR radiometric unit of measure that can be used to definitively compare or predict SWIR camera performance with respect to SNR and range metrics. We propose a unit comparable to the photometric illuminance lux unit; see Ref. [1]. The lack of a SWIR radiometric unit becomes even more critical if one uses lux levels to describe SWIR sensor performance at twilight or even low light condition, since in clear, no-moon conditions in rural areas, the naturally-occurring SWIR radiation from nightglow produces a much higher irradiance than visible starlight. Thus, even well-intentioned efforts to characterize a test site's ambient illumination levels in the SWIR band may fail based on photometric instruments that only measure visible light. A study of this by one of the authors in Ref. [2] showed that the correspondence between lux values and total SWIR irradiance in typical illumination conditions can vary by more than two orders of magnitude, depending on the spectrum of the ambient background. In analogy to the photometric lux definition, we propose the SWIR irradiance equivalent `swux' level, derived by integration over the scene SWIR spectral irradiance weighted by a spectral sensitivity function S(λ), a SWIR analog of the V(λ) photopic response function.

  17. Modeling response variation for radiometric calorimeters

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1986-01-01

    Radiometric calorimeters are widely used in the DOE complex for accountability measurements of plutonium and tritium. Proper characterization of response variation for these instruments is, therefore, vital for accurate assessment of measurement control as well as for propagation of error calculations. This is not difficult for instruments used to measure items within a narrow range of power values; however, when a single instrument is used to measure items over a wide range of power values, improper estimates of uncertainty can result since traditional error models for radiometric calorimeters assume that uncertainty is not a function of sample power. This paper describes methods which can be used to accurately estimate random response variation for calorimeters used to measure items over a wide range of sample powers. The model is applicable to the two most common modes of calorimeter operation: heater replacement and servo control. 5 refs., 4 figs., 1 tab

  18. X-ray radiometric separation of low-grade tin ores

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, N.I.; Neverov, A.D.; Konovalov, V.M.; Mironov, I.I.; Zakharov, S.N.

    1984-10-01

    The investigations on evaluation of X-ray radiometric separation of off-grade tin ores of one of the deposits are carried out. The experiments have been performed at loboratory and pilot-commerical plants. /sup 241/Am has been used as a radiation source. In the course of facility commercial the ore has been separated by means of a device comprising a separator and gate separatin device. The results of X-ray radiometric separation have shown its high productive efficiency. Concentrates with higher tin content at high extraction from ores are obtained.

  19. X-ray radiometric separation of low-grade tin ores

    International Nuclear Information System (INIS)

    Kotler, N.I.; Neverov, A.D.; Konovalov, V.M.; Mironov, I.I.; Zakharov, S.N.

    1984-01-01

    The investigations on evaluation of X-ray radiometric separation of off-grade tin ores of one of the deposits are carried out. The experiments have been performed at loboratory and pilot-commerical plants. 241 Am has been used as a radiation source. In the course of facility commercial the ore has been separated by means of a device comprising a separator and gate separatin device. The results of X-ray radiometric separation have shown its high productive efficiency. Concentrates with higher tin content at high extraction from ores are obtained

  20. The Radiometric Bode's law and Extrasolar Planets

    National Research Council Canada - National Science Library

    Lazio, T. J; Farrell, W. M; Dietrick, Jill; Greenlees, Elizabeth; Hogan, Emily; Jones, Christopher; Hennig, L. A

    2004-01-01

    We predict the radio flux densities of the extrasolar planets in the current census, making use of an empirical relation the radiometric Bode's law determined from the five "magnetic" planets in the solar system...

  1. A new semiquantitative radiometric opsonin assay

    International Nuclear Information System (INIS)

    Yamamura, M.; Valdimarsson, H.

    1978-01-01

    A new semiquantitative radiometric opsonin assay is described. It was found that the opsonin activity generated by incubating brewer's yeast, Saccharomyces cerevisiae, in medium containing less than 5% human serum was exclusively complement dependent. In contrast, C.albicans was effectively opsonized in the absence of complement. Antibodies and the early classical complement pathway did not contribute to the opsonization of S.cerevisiae and neither did C5-9. The brewer's yeast assay can therefore be used for measuring selectively the opsonizing capacity of the alternative pathway. Sera from approximately 7% of apparently healthy adult controls consistently failed to generate significant opsonin activity while 8 out of 26 patients with suspected immune deficiency of unknown cause were defective in this assay. All opsonin deficient sera so far tested had haemolytically normal alternative pathway and Factor B activity. (author)

  2. Conceptual basis for the radiometric dye film dose meter as a test of particle track theory

    International Nuclear Information System (INIS)

    Hansen, J.W.

    1980-05-01

    This report is a summary of a lecture held at the Danish-Polish Symposium on Radiation Chemistry in Warsaw, October 1979, describing an initiated work connected to the particle track theory worked out by R. Katz and coworkers. A short description is given of the theory and the applicability of the theory in the use of the radiometric dye cyanide film dose meter as a detector in radiation of different qualities. A few experimental results are given. (author)

  3. Ultra-sensitive radionuclide spectrometry. Radiometrics and mass spectrometry synergy

    International Nuclear Information System (INIS)

    Povinec, P.P.

    2005-01-01

    Recent developments in radiometrics and mass spectrometry techniques for ultra-sensitive analysis of radionuclides in the marine environment are reviewed. In the radiometrics sector the dominant development has been the utilization of large HPGe detectors in underground laboratories with anti-cosmic or anti-Compton shielding for the analysis of short and medium-lived radionuclides in the environment. In the mass spectrometry sector, applications of inductively coupled plasma mass spectrometry (ICP-MS) and accelerator mass spectrometry (AMS) for the analysis of long-lived radionuclides in the environment are the most important recent achievements. The recent developments do not only considerably decrease the detection limits for several radionuclides (up to several orders of magnitude), but they also enable to decrease sample volumes so that sampling, e.g., of the water column can be much easier and more effective. A comparison of radiometrics and mass spectrometry results for the analysis of radionuclides in the marine environment shows a reasonable agreement - within quoted uncertainties, for wide range of activities and different sample matrices analyzed. (author)

  4. Liquid scintillation vial for radiometric assay of lymphocyte carbohydrate metabolism in response to mitogens

    International Nuclear Information System (INIS)

    Tran, N.; Wagner, H.N. Jr.

    1978-01-01

    We have demonstrated that mitogens--i.e., PHA and Con.A--stimulate lymphocyte carbohydrate metabolism using a liquid-scintillation vial with conventional liquid-scintillation detectors. The results showed that this enclosed system can be useful for development of rapid in vitro tests of lymphocytes immune responsiveness, as well as for radiometric detection of bacterial growth in various gaseous atmospheres

  5. Multielemental X-ray radiometric analysis of ferromanganese concretions

    International Nuclear Information System (INIS)

    Metelev, A.Yu.; Grigor'ev, A.I.; Rakita, K.A.; Mamaenko, M.V.; Ivanenko, V.V.

    1994-01-01

    Ferromanganese concretions are promising mineral resources of the ocean. Most often, they are analyzed by atomic-absorption, spectra, X-ray spectral, neutron-activation, and X-ray radiometric methods. Note that X-ray radiometric analysis (XRRA) allows the sufficiently rapid determination of a great number of elements in ferromanganese concretions. The possibility of using XRRA with saturated and thin layers was shown; however, the data on the precision and accuracy of the technique was not given. The purpose of this study is to evaluate the basic performance characteristics of the multielemental X-ray radiometric analysis of ferromanganese concretions (Pacific Ocean). Determinations for K,Ca and Ti content were made using a 55 Fe source and for Mn, Fe, Ni, Cu, Zn, Pb, Sr, Y, Zr, Nb, and Mo contents by using a 109 Cd source. The precision and accuracy of the method was investigated by using reference concretions; it was found the confidence intervals overlap for all of the elements except Ca and Pb. The relative standard deviation was 1-5%, indicating the high precision of the method. The described technique is successfully used on research vessels of the Far East Division of the Russian Academy of Sciences and in South Pacific Ocean geological expeditions of PO open-quotes Dal'morgeologiyaclose quotes

  6. Testing and differentiation

    DEFF Research Database (Denmark)

    Kousholt, Kristine

    This presentation will explore how educational standardized testing becomes meaningful/not meaningful for children and teachers and at the same time how testing becomes part of everyday differentiation and categorization processes. The presentation is based on a 3 year long post doc project...... and education. It will be explored how the children in their communities construct understandings of themselves as clever or non-clever in relation to how they participate in test situations and in relation to which result they receive afterwards. Furthermore it will be explored how we might understand...... for help. The presentation will end with considerations on how we might understand the growing need for so-called objective assessment which is assumed to be independent of subjective norms and local context....

  7. Radiometric survey in sampling areas of Itataia mine ore and radiometric monitoring in Itataia project sites

    International Nuclear Information System (INIS)

    1982-07-01

    This radiometric survey was done by CDTN, in Itataia sites, on July/82 and it aimed fundamentally to evaluate local radiological conditions, as for aspect of occupational radiation protection. Besides of results obtained, this report has informations of general aspects that ought to serve as subsidies for elaboration of radiological protection program of local. (author) [pt

  8. A design of an on-orbit radiometric calibration device for high dynamic range infrared remote sensors

    Science.gov (United States)

    Sheng, Yicheng; Jin, Weiqi; Dun, Xiong; Zhou, Feng; Xiao, Si

    2017-10-01

    With the demand of quantitative remote sensing technology growing, high reliability as well as high accuracy radiometric calibration technology, especially the on-orbit radiometric calibration device has become an essential orientation in term of quantitative remote sensing technology. In recent years, global launches of remote sensing satellites are equipped with innovative on-orbit radiometric calibration devices. In order to meet the requirements of covering a very wide dynamic range and no-shielding radiometric calibration system, we designed a projection-type radiometric calibration device for high dynamic range sensors based on the Schmidt telescope system. In this internal radiometric calibration device, we select the EF-8530 light source as the calibration blackbody. EF-8530 is a high emittance Nichrome (Ni-Cr) reference source. It can operate in steady or pulsed state mode at a peak temperature of 973K. The irradiance from the source was projected to the IRFPA. The irradiance needs to ensure that the IRFPA can obtain different amplitude of the uniform irradiance through the narrow IR passbands and cover the very wide dynamic range. Combining the internal on-orbit radiometric calibration device with the specially designed adaptive radiometric calibration algorithms, an on-orbit dynamic non-uniformity correction can be accomplished without blocking the optical beam from outside the telescope. The design optimizes optics, source design, and power supply electronics for irradiance accuracy and uniformity. The internal on-orbit radiometric calibration device not only satisfies a series of indexes such as stability, accuracy, large dynamic range and uniformity of irradiance, but also has the advantages of short heating and cooling time, small volume, lightweight, low power consumption and many other features. It can realize the fast and efficient relative radiometric calibration without shielding the field of view. The device can applied to the design and

  9. A Preliminary Analysis of LANDSAT-4 Thematic Mapper Radiometric Performance

    Science.gov (United States)

    Justice, C.; Fusco, L.; Mehl, W.

    1985-01-01

    The NASA raw (BT) product, the radiometrically corrected (AT) product, and the radiometrically and geometrically corrected (PT) product of a TM scene were analyzed examine the frequency distribution of the digital data; the statistical correlation between the bands; and the variability between the detectors within a band. The analyses were performed on a series of image subsets from the full scence. Results are presented from one 1024 c 1024 pixel subset of Realfoot Lake, Tennessee which displayed a representative range of ground conditions and cover types occurring within the full frame image. From this cursory examination of one of the first seven channel TM data sets, it would appear that the radiometric performance of the system is most satisfactory and largely meets pre-launch specifications. Problems were noted with Band 5 Detector 3 and Band 2 Detector 4. Differences were observed between forward and reverse scan detector responses both for the BT and AT products. No systematic variations were observed between odd and even detectors.

  10. RADIOMETRIC CALIBRATION OF MARS HiRISE HIGH RESOLUTION IMAGERY BASED ON FPGA

    Directory of Open Access Journals (Sweden)

    Y. Hou

    2016-06-01

    Full Text Available Due to the large data amount of HiRISE imagery, traditional radiometric calibration method is not able to meet the fast processing requirements. To solve this problem, a radiometric calibration system of HiRISE imagery based on field program gate array (FPGA is designed. The montage gap between two channels caused by gray inconsistency is removed through histogram matching. The calibration system is composed of FPGA and DSP, which makes full use of the parallel processing ability of FPGA and fast computation as well as flexible control characteristic of DSP. Experimental results show that the designed system consumes less hardware resources and the real-time processing ability of radiometric calibration of HiRISE imagery is improved.

  11. Modified and reverse radiometric flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Ba, H; Khin, M M; Aung, K; Thida, [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-06-01

    Determination of [sup 137]Cs and [sup 60]Co by using modified and reverse radiometric flow injection analysis is described. Two component RFIA was also realized using [sup 60]Co and [sup 137]Cs radionuclides. (author) 2 refs.; 5 figs.

  12. Discrepancy between growth of Coccidioides immitis in bacterial blood culture media and a radiometric growth index

    International Nuclear Information System (INIS)

    Ampel, N.M.; Wieden, M.A.

    1988-01-01

    Spherules of Coccidioides immitis grew readily after inoculation in vented trypticase soy broth, biphasic brain heart infusion media, and aerobic tryptic soy broth bottles used in a radiometric system (BACTEC). However, visible growth was not accompanied by a significant radiometric growth index. Growth of C. immitis can be visually detected in routine bacterial blood culture media while the radiometric growth index remains negative

  13. Anomalies from aerial spectrometric and total count radiometric surveys in the southeastern United States

    International Nuclear Information System (INIS)

    Lee, C.H.; Lawton, D.E.

    1978-01-01

    Aerial radiometric reconnaissance surveys are conducted because of their cost, time, and manpower savings compared to surface studies. Two types of aerial surveys are being flown in the southeastern United States: total count gamma-ray surveys for the Coastal Plains Regional Commission and the US Geological Survey, and differential gamma-ray spectrometric surveys for the US Department of Energy. Anomalous radioactivity detected during aerial surveys is related to higher concentrations of naturally occurring uranium, or to cultural activities, natural causes, or mapping errors which simulate real uranium anomalies. Each anomaly should be ground checked; however, several types of anomalies may be eliminated by evaluation of the aerial data in the office if field time is limited

  14. Radiometric determination of monoethanolamine with /sup 65/ZnSo/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R; Sriman Narayanan, S; Rao, V R.S. [Indian Inst. of Tech., Bombay. Dept. of Chemistry

    1984-05-07

    Determination of milligram amounts of monoethanolamine (MEA) with zinc(II) by radiometric titration is described. When MEA is added to a zinc(II) solution containing sulphate ions at 25 degC, a white solid complex is formed. The formation of this complex is employed for the radiometric determination of MEA with /sup 65/Zn. The amount of MEA is directly proportional to the activity of the complex formed. The method is simple, rapid and accurate. 8 refs.

  15. Radiometric and signal-to-noise ratio properties of multiplex dispersive spectrometry

    International Nuclear Information System (INIS)

    Barducci, Alessandro; Guzzi, Donatella; Lastri, Cinzia; Nardino, Vanni; Marcoionni, Paolo; Pippi, Ivan

    2010-01-01

    Recent theoretical investigations have shown important radiometric disadvantages of interferential multiplexing in Fourier transform spectrometry that apparently can be applied even to coded aperture spectrometers. We have reexamined the methods of noninterferential multiplexing in order to assess their signal-to-noise ratio (SNR) performance, relying on a theoretical modeling of the multiplexed signals. We are able to show that quite similar SNR and radiometric disadvantages affect multiplex dispersive spectrometry. The effect of noise on spectral estimations is discussed.

  16. X-Ray and Radiometrics in Geo-Ecological and Geochemical Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Fedyanin, S. N. [Navoi Mining and Metallurgical Combinat (Uzbekistan)

    2014-05-15

    Monitoring of tailing pits of uranium ore conversion products and reserve supplies of low-grade ores stored in dumps is traditionally based on radiation environment on these sites and adjacent territories. The results of gamma-ray spectrometry of solid fractions and radon concentration measurement in liquid and gas phases of technogenic formations are used in radiation hazard evaluation. Radiometric testing practice of low-activity field formations in loose and lump masses shows that due to high emanating ability it is necessary to use dual-channel radiometer for ionizing radiation background record and compensation. Thus gamma-radiometry is not the direct method of uranium content determination and alfa- and beta-radiometry can be correctly used only for sample analysis in laboratory environment. Consequently, distant express testing with the help of X-ray radiometric (XRM) instruments (on calcium, iron, manganese, titanium, copper, arsenic, lead, strontium, selenium, molybdenum, uranium, etc.) is recommended for additional introduction in field observations of radio-ecological environment in mining and processing production tailing and dumps of low-grade ore reserve supplies. Thanks to preliminary areal schemes of geochemical zonality as per XRM data XRM application allows to use the sample limit, given for a wide range of laboratory analyses rationally. Sampling places and their number as well as kinds of laboratory analyses are chosen based on XRM data.It is rather effective to use laboratory variant of atomic absorptive analysis on mercury and stibium in gases (GA), generated in the process of grated samples calcination in muffle furnaces. During the presentation of the report In order to prove the effectiveness of XRM and GA presentation graphics with the results of areal mapping using the above methods and geochemical testing on the territories of Tashkent (Uzbekistan) and Chimkent (Kazakhstan) regions within the framework of the geological and ecological

  17. Radiometric system for clinical applications in the National Health System

    International Nuclear Information System (INIS)

    Mesa Perez, G.; Arteche Diaz, R.; Camejo Batista, A.; Fonfria Bragado, C.

    2013-01-01

    In this paper it is presented the radiometric detection system SRNIC-02, manufactured at CEADEN. The system has three major components: a well-type Nal(TI) scintillator detector with its collimator, a measurement module, and the application software, which allows fixing the working parameters of the system, as well as the acquisition and processing of data. The system has two main applications in the National Health System, one for the quality control in Radiopharmacy, and in RIA/IRMA blood tests. There are 16 systems installed, in 13 provinces of the country up to this date. (Author)

  18. Use of Radiometric Survey Data for Environmental Study: The Case of Northern Sumatera

    International Nuclear Information System (INIS)

    Tjokrokardono, S; Ramadanus; Sustarman, H

    1998-01-01

    The convertion of old radiometric data obtained from former uranium exploration activities in northem sumatra into radiation exposure has been evaluated. The objective of the study is to find an alternative way for cheaper and faster compilation of radiation exposure database for environmental study purposes. The old radiometric data measure from the outcrops has been plotted 1;250.000, 1;100.000, and 1;50.000 map scales. The data are translated into 1;1000.000 map scale before they are converted into 1;1000.000 radiation exposure rate map using a graphic method. The radiation exposure rate in northem sumatera falls between 25 R/hour to 40 R/hour. The benefit offered using this method is that it provides a cheaper and faster production of radiation exposure rate map from old radiometric map. However, the problems arising from such a production is that the radiometric data provide unhomogeneous data distributions and densities among the area. As a conclusion it is recommended to recollect some of the data at designated area using well calibrated SPP2NF and gamma ray spectrometer instruments

  19. Radiometric measuring method for egg shells

    Energy Technology Data Exchange (ETDEWEB)

    Forberg, S; Svaerdstroem, K

    1973-02-01

    A description is given of a fast nondestructive radiometric method for registration of the thickness of egg shells of the tawny owl, hen, osprey, and Canada goose. Certain errors are discussed. Measurement of the thickness of egg shells (mineral content per cm/sup 2/) with an accuracy better than 1% is possible in less than one minute under field conditions. (auth)

  20. Radiometric microbiologic assay for the biologically active forms of niacin

    International Nuclear Information System (INIS)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-01-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced 14 CO 2 from L-[U- 14 C] malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 μg niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays

  1. Radiometric titration of diethanolamine with 65ZnSO4 and determination of mono and diethanolamines in a mixture by a radiometric method

    International Nuclear Information System (INIS)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S.

    1984-01-01

    Radiometric titration of diethanolamine with 65 ZnSO 4 is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate. (author)

  2. THE EUROSDR PROJECT "RADIOMETRIC ASPECTS OF DIGITAL PHOTOGRAMMETRIC IMAGES" – RESULTS OF THE EMPIRICAL PHASE

    Directory of Open Access Journals (Sweden)

    E. Honkavaara

    2012-09-01

    Full Text Available This article presents the empirical research carried out in the context of the multi-site EuroSDR project "Radiometric aspects of digital photogrammetric images" and provides highlights of the results. The investigations have considered the vicarious radiometric and spatial resolution validation and calibration of the sensor system, radiometric processing of the image blocks either by performing relative radiometric block equalization or into absolutely reflectance calibrated products, and finally aspects of practical applications on NDVI layer generation and tree species classification. The data sets were provided by Leica Geosystems ADS40 and Intergraph DMC and the participants represented stakeholders in National Mapping Authorities, software development and research. The investigations proved the stability and quality of evaluated imaging systems with respect to radiometry and optical system. The first new-generation methods for reflectance calibration and equalization of photogrammetric image block data provided promising accuracy and were also functional from the productivity and usability points of view. The reflectance calibration methods provided up to 5% accuracy without any ground reference. Application oriented results indicated that automatic interpretation methods will benefit from the optimal use of radiometrically accurate multi-view photogrammetric imagery.

  3. Radiometric relations of a sugarcane crop

    International Nuclear Information System (INIS)

    Machado, E.C.; Pereira, A.R.; Camargo, M.B.P. de; Fahl, J.I.

    1985-01-01

    The radiometric relations of a sugarcane crop, cv. NA56-79, are studied during the period of maximum leaf area index. The coefficients of reflection, transmission and absorption of the incoming solar radiation were function of solar elevation and the waveband considered. The photosynthetically active radiation was always less reflected and transmitted but more absorved than the near infrared radiation. (M.A.C.) [pt

  4. Radiometric calipers for borehole logging

    International Nuclear Information System (INIS)

    Charbucinski, J.; Wylie, A.W.; Jarrett, R.G.

    1976-01-01

    Two versions of a radiometric-type caliper for measuring borehole diameter are described. One, based on the bow-spring principle, is suitable for percussion (exploration) drill holes. The other, which utilizes hemispherical wall contactors actuated by springs, is suitable for blast holes. Both utilize low-power radioactive sources and employ a scintillation detector to measure the 'inverse-square law' response of the device to changes in borehole radius. The performance of the device is examined and examples of its use are illustrated. (author)

  5. Investigations with a simplified method for radiometric determination of vitamin B12 in body fluids and feeding stuffs

    International Nuclear Information System (INIS)

    Menke, K.H.; Kohlberger, G.; Koenemund, A.

    1979-01-01

    A modified method for radiometrical determination of vitamin B 12 is described, which in difference to the known methods is based on measurement of free B 12 after absorption to albumin-coated charcoal instead of measurement of intrinsic factor B 12 -complex. The conditions for extraction from serum, milk, rumen-liquor and urine have been investigated and the effect of pH on IF-B 12 -binding in presence of these body fluids examined. Parallel microbiological determinations (O.m.- and L.1.-test) were in good correlation (r = 0,93-0,97) to radiometrically determined B 12 -contents in milk and rumen-liquor, but not to that in serum of dairy cows (r = 0,54-0,82). The analytical procedures are given in detail. (orig.) [de

  6. Radiometric Calibration of a Dual-Wavelength, Full-Waveform Terrestrial Lidar.

    Science.gov (United States)

    Li, Zhan; Jupp, David L B; Strahler, Alan H; Schaaf, Crystal B; Howe, Glenn; Hewawasam, Kuravi; Douglas, Ewan S; Chakrabarti, Supriya; Cook, Timothy A; Paynter, Ian; Saenz, Edward J; Schaefer, Michael

    2016-03-02

    Radiometric calibration of the Dual-Wavelength Echidna(®) Lidar (DWEL), a full-waveform terrestrial laser scanner with two simultaneously-pulsing infrared lasers at 1064 nm and 1548 nm, provides accurate dual-wavelength apparent reflectance (ρ(app)), a physically-defined value that is related to the radiative and structural characteristics of scanned targets and independent of range and instrument optics and electronics. The errors of ρ(app) are 8.1% for 1064 nm and 6.4% for 1548 nm. A sensitivity analysis shows that ρ(app) error is dominated by range errors at near ranges, but by lidar intensity errors at far ranges. Our semi-empirical model for radiometric calibration combines a generalized logistic function to explicitly model telescopic effects due to defocusing of return signals at near range with a negative exponential function to model the fall-off of return intensity with range. Accurate values of ρ(app) from the radiometric calibration improve the quantification of vegetation structure, facilitate the comparison and coupling of lidar datasets from different instruments, campaigns or wavelengths and advance the utilization of bi- and multi-spectral information added to 3D scans by novel spectral lidars.

  7. Radiometric microbiologic assay for the biologically active forms of niacin

    Energy Technology Data Exchange (ETDEWEB)

    Kertcher, J.A.; Guilarte, T.R.; Chen, M.F.; Rider, A.A.; McIntyre, P.A.

    1979-05-01

    A radiometric microbiologic assay has been developed for the determination of niacin in biologic fluids. Lactobacillus plantarum produced /sup 14/CO/sub 2/ from L-(U-/sup 14/C) malic acid in quantities proportional to the amount of niacin present. The assay is specific for the biologically active forms of niacin in humans. Thirty normal hemolysates were analyzed and the values ranged from 13.0 to 17.8 ..mu..g niacin/ml RBC (mean = 15.27 +- 1.33 s.d.). Good recovery and reproducibility studies were obtained with this assay. On thirty blood samples, correlation was excellent between the radiometric and the conventional turbidimetric assays.

  8. ANALYSIS OF THE RADIOMETRIC RESPONSE OF ORANGE TREE CROWN IN HYPERSPECTRAL UAV IMAGES

    Directory of Open Access Journals (Sweden)

    N. N. Imai

    2017-10-01

    Full Text Available High spatial resolution remote sensing images acquired by drones are highly relevant data source in many applications. However, strong variations of radiometric values are difficult to correct in hyperspectral images. Honkavaara et al. (2013 presented a radiometric block adjustment method in which hyperspectral images taken from remotely piloted aerial systems – RPAS were processed both geometrically and radiometrically to produce a georeferenced mosaic in which the standard Reflectance Factor for the nadir is represented. The plants crowns in permanent cultivation show complex variations since the density of shadows and the irradiance of the surface vary due to the geometry of illumination and the geometry of the arrangement of branches and leaves. An evaluation of the radiometric quality of the mosaic of an orange plantation produced using images captured by a hyperspectral imager based on a tunable Fabry-Pérot interferometer and applying the radiometric block adjustment method, was performed. A high-resolution UAV based hyperspectral survey was carried out in an orange-producing farm located in Santa Cruz do Rio Pardo, state of São Paulo, Brazil. A set of 25 narrow spectral bands with 2.5 cm of GSD images were acquired. Trend analysis was applied to the values of a sample of transects extracted from plants appearing in the mosaic. The results of these trend analysis on the pixels distributed along transects on orange tree crown showed the reflectance factor presented a slightly trend, but the coefficients of the polynomials are very small, so the quality of mosaic is good enough for many applications.

  9. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  10. Optical Imaging and Radiometric Modeling and Simulation

    Science.gov (United States)

    Ha, Kong Q.; Fitzmaurice, Michael W.; Moiser, Gary E.; Howard, Joseph M.; Le, Chi M.

    2010-01-01

    OPTOOL software is a general-purpose optical systems analysis tool that was developed to offer a solution to problems associated with computational programs written for the James Webb Space Telescope optical system. It integrates existing routines into coherent processes, and provides a structure with reusable capabilities that allow additional processes to be quickly developed and integrated. It has an extensive graphical user interface, which makes the tool more intuitive and friendly. OPTOOL is implemented using MATLAB with a Fourier optics-based approach for point spread function (PSF) calculations. It features parametric and Monte Carlo simulation capabilities, and uses a direct integration calculation to permit high spatial sampling of the PSF. Exit pupil optical path difference (OPD) maps can be generated using combinations of Zernike polynomials or shaped power spectral densities. The graphical user interface allows rapid creation of arbitrary pupil geometries, and entry of all other modeling parameters to support basic imaging and radiometric analyses. OPTOOL provides the capability to generate wavefront-error (WFE) maps for arbitrary grid sizes. These maps are 2D arrays containing digital sampled versions of functions ranging from Zernike polynomials to combination of sinusoidal wave functions in 2D, to functions generated from a spatial frequency power spectral distribution (PSD). It also can generate optical transfer functions (OTFs), which are incorporated into the PSF calculation. The user can specify radiometrics for the target and sky background, and key performance parameters for the instrument s focal plane array (FPA). This radiometric and detector model setup is fairly extensive, and includes parameters such as zodiacal background, thermal emission noise, read noise, and dark current. The setup also includes target spectral energy distribution as a function of wavelength for polychromatic sources, detector pixel size, and the FPA s charge

  11. Radiometric analyzer with plural radiation sources and detectors

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring characteristics of a material by radiation comprises a plurality of systems in which each consists of a radiation source and a radiation detector which are the same in number as the number of elements of the molecule of the material and a linear calibration circuit having inverse response characteristics (calibration curve) of the respective systems of detectors, whereby the measurement is carried out by four fundamental rules by operation of the mutual outputs of said detector system obtained through said linear calibration circuit. One typical embodiment is a radiometric analyzer for hydrocarbons which measures the density of heavy oil, the sulfur content and the calorific value by three detector systems which include a γ-ray source (E/sub γ/ greater than 50 keV), a soft x-ray source (Ex approximately 20 keV), and a neutron ray source. 2 claims, 6 figures

  12. Determination of in vitro susceptibility of Mycobacterium tuberculosis to cephalosporins by radiometric and conventional methods

    International Nuclear Information System (INIS)

    Heifets, L.B.; Iseman, M.D.; Cook, J.L.; Lindholm-Levy, P.J.; Drupa, I.

    1985-01-01

    Among eight cephalosporins and cephamycins tested in preliminary in vitro screening against Mycobacterium tuberculosis, the most promising for further study was found to be ceforanide, followed by ceftizoxime, cephapirin, and cefotaxime. Moxalactam, cefoxitin, cefamandole, and cephalothin were found to be not active enough against M. tuberculosis to be considered for further in vitro studies. The antibacterial activity of various ceforanide concentrations was investigated by three methods: (i) the dynamics of radiometric readings (growth index) in 7H12 broth; (ii) the number of CFU in the same medium; and (iii) the proportion method on 7H11 agar plates. There was a good correlation among the results obtained with these methods. The MIC for most strains ranged from 6.0 to 25.0 micrograms/ml. The BACTEC radiometric method is a reliable, rapid, and convenient method for preliminary screening and determination of the level of antibacterial activity of drugs not commonly used against M. tuberculosis

  13. Radiometric flow injection analysis with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    Radiometric Flow Injection Analysis of a radioactive ([sup 131]I) sample is described. For analysis an ASIA (Ismatec) analyzer with a NaI(Tl) scintillation detector was used. (author) 5 refs.; 3 figs.

  14. Improved detection of Mycobacterium avium complex with the Bactec radiometric system

    International Nuclear Information System (INIS)

    Hoffner, S.E.

    1988-01-01

    A reconsideration of the laboratory methods used for primary isolation of mycobacteria other than Mycobacterium tuberculosis is needed due to the increasingly recognized importance of such mycobacterial infections in immunocompromised patients. One example of this is the severe opportunistic infections caused by Mycobacterium avium complex among AIDS patients. In this study, the Bactec radiometric system was compared to conventional culture on solid medium for the detection of M. avium complex in 3,612 selected clinical specimens, mainly of extrapulmonary origin. Of a total number of 63 M. avium complex isolates, the Bactec system detected 58 (92%), compared to 37 (59%) for conventional culture. A much more rapid detection was attained with radiometric technique than with conventional culture. The mean detection time for the cultures positive with both methods was 7.1 and 28.3 days, respectively. The Bactec radiometric system achieves a rapid and significantly more sensitive detection and seems to be an excellent complement to conventional culture in the laboratory diagnosis of infections with the M. avium complex

  15. Merging airborne and carborne radiometric data for surveying the Deir Az-Zor area, Syria

    International Nuclear Information System (INIS)

    Jubeli, Y.M.; Aissa, M.; Al-Hent, R.

    1997-01-01

    To complete the radiometric map of Syria, and to estimate the natural background radiation levels for environmental monitoring, a carborne survey was undertaken over the Deir Az-Zor area. This area was not covered by a previous airborne survey, except for peripheral regions in the south and west. To complete the radiometric map, results of the carborne and airborne surveys had to be merged. This paper presents the merging procedure which was used after normalizing the two data sets to match each other. No anomalies suitable for radioelement exploration were found. However, the overall radiometric maps resulting from the present work were consistent with the maps of the areas covered by the airborne survey. (author)

  16. Microsomal aryl hydrocarbon hydroxylase comparison of the direct, indirect and radiometric assays

    International Nuclear Information System (INIS)

    Denison, M.S.; Murray, M.; Wilkinson, C.F.

    1983-01-01

    The direct fluorometric assay of aryl hydrocarbon hydroxlyase has been compared to the more commonly used indirect fluorometric and radiometric assays. Although rat hepatic microsomal activities measured by the direct assay were consistently higher than those obtained by the other assays, the relative changes in activity following enzyme induction and/or inhibition were similar. The direct assay provides an accurate and rapid measure of aryl hydrocarbon hydroxylase activity and avoids several problems inherent in the indirect and radiometric assays. 2 tables

  17. Rapid radiometric method for detection of Salmonella in foods

    International Nuclear Information System (INIS)

    Stewart, B.J.; Eyles, M.J.; Murrell, W.G.

    1980-01-01

    A radiometric method for the detection of Salmonella in foods has been developed which is based on Salmonella poly H agglutinating serum preventing Salmonella from producing 14CO2 from [14C] dulcitol. The method will detect the presence or absence of Salmonella in a product within 30 h compared to 4 to 5 days by routine culture methods. The method has been evaluated against a routine culture method using 58 samples of food. The overall agreement was 91%. Five samples negative for Salmonella by the routine method were positive by the radiometric method. These may have been false positives. However, the routine method may have failed to detect Salmonella due to the presence of large numbers of lactose-fermenting bacteria which hindered isolation of Salmonella colonies on the selective agar plates

  18. Radiometric control for P/sub 2/O/sub 5/ content in Polpinsky are deposit phosphorites

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, M A; Berenshtein, M L; Startsev, V K; Akindinov, V A

    1977-01-01

    Results are cited of laboratory research into the possibility of radiometric determination of P/sub 2/O/sub 5/ in phosphorites of Polpinsky deposit. On the basis of the studies performed, a plant and methods have been developed for the continuous control of P/sub 2/O/sub 5/ content in ore. The plant has been tested at the Bryansk phosphorite works. The accuracy of analysis is 0.8 percent.

  19. High speed radiometric measurements of IED detonation fireballs

    Science.gov (United States)

    Spidell, Matthew T.; Gordon, J. Motos; Pitz, Jeremey; Gross, Kevin C.; Perram, Glen P.

    2010-04-01

    Continuum emission is predominant in fireball spectral phenomena and in some demonstrated cases, fine detail in the temporal evolution of infrared spectral emissions can be used to estimate size and chemical composition of the device. Recent work indicates that a few narrow radiometric bands may reveal forensic information needed for the explosive discrimination and classification problem, representing an essential step in moving from "laboratory" measurements to a rugged, fieldable system. To explore phenomena not observable in previous experiments, a high speed (10μs resolution) radiometer with four channels spanning the infrared spectrum observed the detonation of nine home made explosive (HME) devices in the 0.98) using blast model functional forms, suggesting that energy release could be estimated from single-pixel radiometric detectors. Comparison of radiometer-derived fireball size with FLIR infrared imagery indicate the Planckian intensity size estimates are about a factor of two smaller than the physical extent of the fireball.

  20. Remote sensing, airborne radiometric survey and aeromagnetic survey data processing and analysis

    International Nuclear Information System (INIS)

    Dong Xiuzhen; Liu Dechang; Ye Fawang; Xuan Yanxiu

    2009-01-01

    Taking remote sensing data, airborne radiometric data and aero magnetic survey data as an example, the authors elaborate about basic thinking of remote sensing data processing methods, spectral feature analysis and adopted processing methods, also explore the remote sensing data combining with the processing of airborne radiometric survey and aero magnetic survey data, and analyze geological significance of processed image. It is not only useful for geological environment research and uranium prospecting in the study area, but also reference to applications in another area. (authors)

  1. A study on the radiometric method for evaluating element migration from plastic packagings to its contents

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez

    2008-01-01

    migration detection limits were determined. Results from the analyses of the neutron irradiated plastic packagings by differential scanning calorimetry and Fourier transform infrared spectroscopy showed that in high density polyethylene packagings oxidative degradation can occur. Among the main advantages of the radiometric method application for element migration evaluation are its simplicity, no need of blank analysis and the possibility to obtain element migration to the food itself. The results obtained indicated the potentiality of using this method in the element migration evaluation from the plastic packagings to their contents. (author)

  2. Paleomagnetic, paleontologic and radiometric study of the Uquia Formation (Plio-Pleistocene) in Esquina Blanca (Jujuy)

    International Nuclear Information System (INIS)

    Walther, Ana M.; Orgeira, Maria J.; Vilas, Juan F.A.; Kelley, Shari; Jordan, Teresa

    1998-01-01

    A multidisciplinary study of the Uquia Formation has been performed. The results of the paleontologic, paleomagnetic, radiometric and stratigraphic analyses suggest that the superior levels of the formation are equivalent to the 'Marplatense Superior', while the basic ones should be considered older. Radiometric ages have been determined by fission tracks in zircons

  3. Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ and determination of mono and diethanolamines in a mixture by a radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Varadan, R.; Sriman Narayanan, S.; Rao, V.R.S. (Indian Inst. of Tech., Madras. Dept. of Chemistry)

    1984-08-16

    Radiometric titration of diethanolamine with /sup 65/ZnSO/sub 4/ is reported. Determination of individual amounts of mono- and diethanolamines in a mixture is described. The procedure is simple, rapid and accurate.

  4. kCCA Transformation-Based Radiometric Normalization of Multi-Temporal Satellite Images

    Directory of Open Access Journals (Sweden)

    Yang Bai

    2018-03-01

    Full Text Available Radiation normalization is an essential pre-processing step for generating high-quality satellite sequence images. However, most radiometric normalization methods are linear, and they cannot eliminate the regular nonlinear spectral differences. Here we introduce the well-established kernel canonical correlation analysis (kCCA into radiometric normalization for the first time to overcome this problem, which leads to a new kernel method. It can maximally reduce the image differences among multi-temporal images regardless of the imaging conditions and the reflectivity difference. It also perfectly eliminates the impact of nonlinear changes caused by seasonal variation of natural objects. Comparisons with the multivariate alteration detection (CCA-based normalization and the histogram matching, on Gaofen-1 (GF-1 data, indicate that the kCCA-based normalization can preserve more similarity and better correlation between an image-pair and effectively avoid the color error propagation. The proposed method not only builds the common scale or reference to make the radiometric consistency among GF-1 image sequences, but also highlights the interesting spectral changes while eliminates less interesting spectral changes. Our method enables the application of GF-1 data for change detection, land-use, land-cover change detection etc.

  5. JPSS-1 VIIRS Pre-Launch Radiometric Performance

    Science.gov (United States)

    Oudrari, Hassan; Mcintire, Jeffrey; Xiong, Xiaoxiong; Butler, James; Ji, Qiang; Schwarting, Tom; Zeng, Jinan

    2015-01-01

    The first Joint Polar Satellite System (JPSS-1 or J1) mission is scheduled to launch in January 2017, and will be very similar to the Suomi-National Polar-orbiting Partnership (SNPP) mission. The Visible Infrared Imaging Radiometer Suite (VIIRS) on board the J1 spacecraft completed its sensor level performance testing in December 2014. VIIRS instrument is expected to provide valuable information about the Earth environment and properties on a daily basis, using a wide-swath (3,040 km) cross-track scanning radiometer. The design covers the wavelength spectrum from reflective to long-wave infrared through 22 spectral bands, from 0.412 m to 12.01 m, and has spatial resolutions of 370 m and 740 m at nadir for imaging and moderate bands, respectively. This paper will provide an overview of pre-launch J1 VIIRS performance testing and methodologies, describing the at-launch baseline radiometric performance as well as the metrics needed to calibrate the instrument once on orbit. Key sensor performance metrics include the sensor signal to noise ratios (SNRs), dynamic range, reflective and emissive bands calibration performance, polarization sensitivity, bands spectral performance, response-vs-scan (RVS), near field response, and stray light rejection. A set of performance metrics generated during the pre-launch testing program will be compared to the sensor requirements and to SNPP VIIRS pre-launch performance.

  6. Radiometric dating by alpha spectrometry on uranium series nuclides

    NARCIS (Netherlands)

    Wijk, Albert van der

    1987-01-01

    De Engelse titel van dit proegschrift \\"Radiometric Dating by Alpha Spectometry on Uranium Series Nuclides\\" kan in het Nederlands wellicht het best worden weergegeven door \\"ouderdomsdbepalingen door stralingsmeting aan kernen uit de uraniumreeks met behulp van alfaspectometrie\\". In dit laatste

  7. Substoichiometric method in the simple radiometric analysis

    International Nuclear Information System (INIS)

    Ikeda, N.; Noguchi, K.

    1979-01-01

    The substoichiometric method is applied to simple radiometric analysis. Two methods - the standard reagent method and the standard sample method - are proposed. The validity of the principle of the methods is verified experimentally in the determination of silver by the precipitation method, or of zinc by the ion-exchange or solvent-extraction method. The proposed methods are simple and rapid compared with the conventional superstoichiometric method. (author)

  8. Use of HPLC with flow-through radiometric detection for low level environmental analysis

    International Nuclear Information System (INIS)

    Mao, J.; Fackler, P.H.

    1992-01-01

    High Performance Liquid Chromatography with flow-through radiometric detection (HPLC-RAM) is increasingly becoming a standard analytical technique in pharmaceutical, agricultural and chemical industries for monitoring radiolabeled analytes. This paper focuses on the applications of this flow-through radiochromatographic technique for low level aquatic toxicology and environmental fate testing. Examples include parts per billion water, sediment/soil and fish tissue analyses using reverse phase as well as normal phase HPLC. The applications of both homogeneous (liquid) and heterogeneous (solid) flow cell scintillation counting are addressed. Compounds discussed are primarily pesticides and pharmaceuticals

  9. Radiometric probe design for the measurement of heat flux within a solid rocket motor nozzle

    Science.gov (United States)

    Goldey, Charles L.; Laughlin, William T.; Popper, Leslie A.

    1996-11-01

    Improvements to solid rocket motor (SRM) nozzle designs and material performance is based on the ability to instrument motors during test firings to understand the internal combustion processes and the response of nozzle components to the severe heating environment. Measuring the desired parameters is very difficult because the environment inside of an SRM is extremely severe. Instrumentation can be quickly destroyed if exposed to the internal rocket motor environment. An optical method is under development to quantify the heating of the internal nozzle surface. A radiometric probe designed for measuring the thermal response and material surface recession within a nozzle while simultaneously confining the combustion products has been devised and demonstrated. As part of the probe design, optical fibers lead to calibrated detectors that measure the interior nozzle thermal response. This two color radiometric measurement can be used for a direct determination of the total heat flux impinging on interior nozzle surfaces. This measurement has been demonstrated using a high power CO2 laser to simulate SRM nozzle heating conditions on carbon phenolic and graphite phenolic materials.

  10. Test generator development for differential equations for lms moodle

    Directory of Open Access Journals (Sweden)

    Анна Александровна Муханова

    2014-12-01

    Full Text Available This article discusses the basic mechanisms of the test generator for differential equations, developed by the authors. The generator is designed to generate a large number of test questions in accordance with user-defined rules, which include: the number of tasks required for each type of differential equation, and the tasks difficulty, controlled by the nesting level of recursive functions. The generator produces a test file format GIFT, which is a plain text file.

  11. Determination of degree of compacting and of moisture content by radiometric probes

    International Nuclear Information System (INIS)

    Martinec, J.; Paul, P.

    1977-01-01

    A survey is given of radiometric probes used for measuring bulk density and moisture content. Surface probes are used in depths of up to 20 cm with an accuracy of 10%, drive-in probes are used to depths of up to 50 cm with a 4% error, depth probes are used for measuring in depths of 30 to 50 cm with an accuracy of roughly 5% and bulk density in depths of 10 to 150 cm may be measured with an accuracy of 2% using a lysimeter. Changes in the bulk density and soil moisture of the subsoil of an airport runway were studied radiometrically in dependence on time and depth. The dependence is represented graphically. The results of radiometric measurements were compared with the conventional method using a lysimeter probe; the comparison showed that the results were lower by about 7% for the moisture content and higher by about 8% for the bulk density. Radiometric measurements for determining bulk density and soil moisture are advantageous in that they allow the measurement of a great number of sites without any major disturbance of the measured material and results are available immediately on measurement. The economic effect is significant in a large number of measurements carried out on a surface having the same chemical composition and similar grain size which does not necessitate calibration of the instruments to be made more than once a week. The NZK-201 probe by Tesla does not provide sufficiently accurate information on the moisture and density of the earths probed

  12. Evaluation of Two Absolute Radiometric Normalization Algorithms for Pre-processing of Landsat Imagery

    Institute of Scientific and Technical Information of China (English)

    Xu Hanqiu

    2006-01-01

    In order to evaluate radiometric normalization techniques, two image normalization algorithms for absolute radiometric correction of Landsat imagery were quantitatively compared in this paper, which are the Illumination Correction Model proposed by Markham and Irish and the Illumination and Atmospheric Correction Model developed by the Remote Sensing and GIS Laboratory of the Utah State University. Relative noise, correlation coefficient and slope value were used as the criteria for the evaluation and comparison, which were derived from pseudo-invariant features identified from multitemtween the normalized multitemporal images were significantly reduced when the seasons of multitemporal images were different. However, there was no significant difference between the normalized and unnormalized images with a similar seasonal condition. Furthermore, the correction results of two algorithms are similar when the images are relatively clear with a uniform atmospheric condition. Therefore, the radiometric normalization procedures should be carried out if the multitemporal images have a significant seasonal difference.

  13. ANALYZING SPECTRAL CHARACTERISTICS OF SHADOW AREA FROM ADS-40 HIGH RADIOMETRIC RESOLUTION AERIAL IMAGES

    Directory of Open Access Journals (Sweden)

    Y.-T. Hsieh

    2016-06-01

    Full Text Available The shadows in optical remote sensing images are regarded as image nuisances in numerous applications. The classification and interpretation of shadow area in a remote sensing image are a challenge, because of the reduction or total loss of spectral information in those areas. In recent years, airborne multispectral aerial image devices have been developed 12-bit or higher radiometric resolution data, including Leica ADS-40, Intergraph DMC. The increased radiometric resolution of digital imagery provides more radiometric details of potential use in classification or interpretation of land cover of shadow areas. Therefore, the objectives of this study are to analyze the spectral properties of the land cover in the shadow areas by ADS-40 high radiometric resolution aerial images, and to investigate the spectral and vegetation index differences between the various shadow and non-shadow land covers. According to research findings of spectral analysis of ADS-40 image: (i The DN values in shadow area are much lower than in nonshadow area; (ii DN values received from shadowed areas that will also be affected by different land cover, and it shows the possibility of land cover property retrieval as in nonshadow area; (iii The DN values received from shadowed regions decrease in the visible band from short to long wavelengths due to scattering; (iv The shadow area NIR of vegetation category also shows a strong reflection; (v Generally, vegetation indexes (NDVI still have utility to classify the vegetation and non-vegetation in shadow area. The spectral data of high radiometric resolution images (ADS-40 is potential for the extract land cover information of shadow areas.

  14. Vicarious absolute radiometric calibration of GF-2 PMS2 sensor using permanent artificial targets in China

    Science.gov (United States)

    Liu, Yaokai; Li, Chuanrong; Ma, Lingling; Wang, Ning; Qian, Yonggang; Tang, Lingli

    2016-10-01

    GF-2, launched on August 19 2014, is one of the high-resolution land resource observing satellite of the China GF series satellites plan. The radiometric performance evaluation of the onboard optical pan and multispectral (PMS2) sensor of GF-2 satellite is very important for the further application of the data. And, the vicarious absolute radiometric calibration approach is one of the most useful way to monitor the radiometric performance of the onboard optical sensors. In this study, the traditional reflectance-based method is used to vicarious radiometrically calibrate the onboard PMS2 sensor of GF-2 satellite using three black, gray and white reflected permanent artificial targets located in the AOE Baotou site in China. Vicarious field calibration campaign were carried out in the AOE-Baotou calibration site on 22 April 2016. And, the absolute radiometric calibration coefficients were determined with in situ measured atmospheric parameters and surface reflectance of the permanent artificial calibration targets. The predicted TOA radiance of a selected desert area with our determined calibrated coefficients were compared with the official distributed calibration coefficients. Comparison results show a good consistent and the mean relative difference of the multispectral channels is less than 5%. Uncertainty analysis was also carried out and a total uncertainty with 3.87% is determined of the TOA radiance.

  15. Calibrated infrared ground/air radiometric spectrometer

    Science.gov (United States)

    Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.

    1996-06-01

    The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).

  16. Development and application of a radiometric method of measurement (Heger probe) for characterizing clastic rock strata in exposures

    International Nuclear Information System (INIS)

    Koch, G.

    1984-01-01

    The radiometric image of a stratigraphic exposure profile was to be logged. The method of measurement was tested on clastic sediments of the Tertiary (Saudi Arabia) and Bunter (Northern Germany). The well-tried scintillometer technique was supplemented by modern technological means supplied by a prospecting company (Gewerkschaft Brunhilde). The probe applied was specifically developped for stratigraphic purposes. (orig./HP) [de

  17. preliminary geological and radiometric studies of granitoids of zing

    African Journals Online (AJOL)

    DJFLEX

    laboratory of Geology Department, Federal University of. Technology, Yola where they were thin sectioned and petrographically studied using a high magnification polarising microscope. Canada balsam was used as the mounting medium. Radiometric survey was carried out using a McPhar model TC-33A portable gamma ...

  18. Radiometric measurement independent of profile. Belt weighers

    International Nuclear Information System (INIS)

    Otto, J.

    1986-01-01

    Radiometric measuring techniques allow contactless determination of the material carried by belt conveyors. Data defining the material is obtained via attenuation of gamma rays passing through the material on the belt. The method applies the absorption law according to Lambert-Beer, which has to be corrected by a build-up factor because of the stray radiation induced by the Compton effect. The profile-dependent error observed with conventional radiometric belt weighers is caused by the non-linearity of the absorption law in connection with the simultaneous summation of the various partial rays in a detector. The scanning method allows separate evaluation of the partial rays' attenuation and thus yields the correct data of the material carried, regardless of the profile. The scanning method is applied on a finite number of scanning sections, and a residual error has to be taken into account. The stochastics of quantum emission and absorption leads to an error whose expectation value is to be taken into account in the scanning algorithm. As the conveyor belt is in motion during the process of measurements, only part of the material conveyed is irradiated. The resulting assessment error is investigated as a function of the autocorrelation function of the material on the belt. (orig./HP) [de

  19. Application of radiometric method to determine P/sub 2/O/sub 5/ at Verkhnekamsk phosphorite mine

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, M A; Terent' ev, E P; Anderzhanov, V N

    1981-01-01

    Correlations between P/sub 2/O/sub 5/ content and natural radioactivity in phosphorites of Vjatsko-Kamsk deposits and products of their enrichment, are considered. A scheme of an installation to conduct continuous radiometric control of P/sub 2/O/sub 5/ content in the pulp flow is presented. The results of the installation test at Verkhnekamsk phosphorite mine to control P/sub 2/O/sub 5/ content in the flow final rejects are given.

  20. Transportable high sensitivity small sample radiometric calorimeter

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-01-01

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most 238 Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size

  1. Inverting radiometric measurements with a neural network

    Science.gov (United States)

    Measure, Edward M.; Yee, Young P.; Balding, Jeff M.; Watkins, Wendell R.

    1992-02-01

    A neural network scheme for retrieving remotely sensed vertical temperature profiles was applied to observed ground based radiometer measurements. The neural network used microwave radiance measurements and surface measurements of temperature and pressure as inputs. Because the microwave radiometer is capable of measuring 4 oxygen channels at 5 different elevation angles (9, 15, 25, 40, and 90 degs), 20 microwave measurements are potentially available. Because these measurements have considerable redundancy, a neural network was experimented with, accepting as inputs microwave measurements taken at 53.88 GHz, 40 deg; 57.45 GHz, 40 deg; and 57.45, 90 deg. The primary test site was located at White Sands Missile Range (WSMR), NM. Results are compared with measurements made simultaneously with balloon borne radiosonde instruments and with radiometric temperature retrievals made using more conventional retrieval algorithms. The neural network was trained using a Widrow-Hoff delta rule procedure. Functions of date to include season dependence in the retrieval process and functions of time to include diurnal effects were used as inputs to the neural network.

  2. Radiometric mass flow probes for belt weighers - the state of the art and possibilities of application

    International Nuclear Information System (INIS)

    Glaeser, M.

    1986-01-01

    The setup of radiometric belt weighers is described in principle and compared with conventional ones. Fields of application are mentioned and a list is given of equipment comercially available. The comparison shows that the radiometric systems are advantageous in general, but in special cases (measuring error lower than 1%, chemical composition varies several 10%) gravimetric systems are indispensable

  3. Assessment of Aero-radiometric Data of Southern Anambra Basin ...

    African Journals Online (AJOL)

    High-resolution aero-radiometric data from three radio-elements (Uranium, Potassium and Thorium) were used and processed independently to investigate the Southern Anambra basin for the prospect of producing radiogenic heat. The rock types in the study area were outlined while processing the elements in each rock ...

  4. Mixing geometric and radiometric features for change classification

    Science.gov (United States)

    Fournier, Alexandre; Descombes, Xavier; Zerubia, Josiane

    2008-02-01

    Most basic change detection algorithms use a pixel-based approach. Whereas such approach is quite well defined for monitoring important area changes (such as urban growth monitoring) in low resolution images, an object based approach seems more relevant when the change detection is specifically aimed toward targets (such as small buildings and vehicles). In this paper, we present an approach that mixes radiometric and geometric features to qualify the changed zones. The goal is to establish bounds (appearance, disappearance, substitution ...) between the detected changes and the underlying objects. We proceed by first clustering the change map (containing each pixel bitemporal radiosity) in different classes using the entropy-kmeans algorithm. Assuming that most man-made objects have a polygonal shape, a polygonal approximation algorithm is then used in order to characterize the resulting zone shapes. Hence allowing us to refine the primary rough classification, by integrating the polygon orientations in the state space. Tests are currently conducted on Quickbird data.

  5. Geometric Calibration and Radiometric Correction of the Maia Multispectral Camera

    Science.gov (United States)

    Nocerino, E.; Dubbini, M.; Menna, F.; Remondino, F.; Gattelli, M.; Covi, D.

    2017-10-01

    Multispectral imaging is a widely used remote sensing technique, whose applications range from agriculture to environmental monitoring, from food quality check to cultural heritage diagnostic. A variety of multispectral imaging sensors are available on the market, many of them designed to be mounted on different platform, especially small drones. This work focuses on the geometric and radiometric characterization of a brand-new, lightweight, low-cost multispectral camera, called MAIA. The MAIA camera is equipped with nine sensors, allowing for the acquisition of images in the visible and near infrared parts of the electromagnetic spectrum. Two versions are available, characterised by different set of band-pass filters, inspired by the sensors mounted on the WorlView-2 and Sentinel2 satellites, respectively. The camera details and the developed procedures for the geometric calibrations and radiometric correction are presented in the paper.

  6. Radiometric--microbiologic assay of vitamin B-6: application to food analysis

    International Nuclear Information System (INIS)

    Guilarte, T.R.; Shane, B.; McIntyre, P.A.

    1981-01-01

    A radiometric microbiologic assay for vitamin B-6 was applied to food analysis. The method was shown to be specific, reproducible and simpler than the standard turbidimetric microbiologic technique. The analysis of seven commercially available breakfast cereals was compared to a high performance liquid chromatography method. Three out of the seven cereals agreed when assayed with both methods (P greater than 0.1). Four cereals, however, differed in value considerably (P less than 0.05). Further studies are required to determine whether these differences were due to different extraction procedures used. The study showed that the new radiometric-microbiologic method can be used to measure total vitamin B-6 or, combined with a column separation procedure, to analyze for specific forms of the vitamin

  7. MER 1 MARS NAVCAM 3 RADIOMETRIC RDR SCI V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains radiometrically calibrated MER-1 Navcam data. The calibration has removed bias, dark current, and flatfield effects from the raw Navcam data,...

  8. Pukaki 1-01 : initial luminescence dating and radiometric measurements

    International Nuclear Information System (INIS)

    Rieser, U.

    2001-01-01

    Core from Pukaki 1-01 was sampled for luminescence dating and radiometric measurements on 14 March 2001 in the dark room laboratory at Victoria University. Seven samples were taken to get an overview of the crater history, and laboratory work was completed in August 2001. (author). 2 figs., 3 tabs

  9. Set-up for differential manometers testing

    International Nuclear Information System (INIS)

    Ratushnyj, M.I.; Galkin, Yu.V.; Nechaj, A.G.

    1985-01-01

    Set-up characteristic for controlling and testing metrological characteristics of TPP and NPP differential manometers with extreme pressure drop upto 250 kPa is briefly described. The set-up provides with automatic and manual assignment of values of gauge air pressure with errors of 0.1 and 0.25% correspondingly. The set-up is supplied with standard equipment to measure output signals. Set-up supply is carried out by a one-phase alternating current circuit with 220 V. Air supply is carried out by O.4-0.6 MPa. pressure of a pneumatic system. Application of the set-up increases operating efficiency 5 times while checking and turning differential manometers

  10. A new relative radiometric consistency processing method for change detection based on wavelet transform and a low-pass filter

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The research purpose of this paper is to show the limitations of the existing radiometric normalization approaches and their disadvantages in change detection of artificial objects by comparing the existing approaches,on the basis of which a preprocessing approach to radiometric consistency,based on wavelet transform and a spatial low-pass filter,has been devised.This approach first separates the high frequency information and low frequency information by wavelet transform.Then,the processing of relative radiometric consistency based on a low-pass filter is conducted on the low frequency parts.After processing,an inverse wavelet transform is conducted to obtain the results image.The experimental results show that this approach can substantially reduce the influence on change detection of linear or nonlinear radiometric differences in multi-temporal images.

  11. Basing of principles and methods of operation of radiometric control and measurement systems

    International Nuclear Information System (INIS)

    Onishchenko, A.M.

    1995-01-01

    Six basic stages of optimization of radiometric systems, methods of defining the preset components of total error and the choice of principles and methods of measurement are described in succession. The possibility of simultaneous optimization of several stages, turning back to the already passed stages, is shown. It is suggested that components of the total error should be preset as identical ones for methodical, instrument, occasional and representativity errors and the greatest of the components should be decreased first of all. Comparative table for 64 radiometric methods of measurement by 11 indices of the methods quality is presented. 2 refs., 1 tab

  12. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    Science.gov (United States)

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  13. Characterisation of radioactive contaminated materials by combined radiometric and spectrometric methods

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, A.; Dobrin, R.; Ciocîrlan, C.; Stoica, S.; Valeca, M.; Popescu, I. I.

    2013-01-01

    In the present paper, a combined analytical methodology is described, for characterization of radioactive contaminated materials. The subject of testing activities was a set of solutions provided by the Cernavoda NPP, which are originating from processes of radiological survey of workplaces in the plant. In the introduction section, a theoretical approach was given to the origin and nature of main radionuclides occurring in the primary cooling system of the nuclear power plant, with the aim to establish selection criteria and performance requirements for the analytical methods to be used in the development of the characterization methodology. A combination of radiometric and spectrometric methods was selected, based on gross beta counting, high resolution gamma-ray spectrometry and liquid scintillation counting. (authors)

  14. Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials

    International Nuclear Information System (INIS)

    Plorde, J.J.; Carlson, L.G.; Dau, M.E.

    1982-01-01

    During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture

  15. Temperature effect compensation for fast differential pressure decay testing

    International Nuclear Information System (INIS)

    Shi, Yan; Tong, Xiaomeng; Cai, Maolin

    2014-01-01

    To avoid the long temperature recovery period with differential pressure decay for leak detection, a novel method with temperature effect compensation is proposed to improve the testing efficiency without full stabilization of temperature. The mathematical model of conventional differential pressure decay testing is established to analyze the changes of temperature and pressure during the measuring period. Then the differential pressure is divided into two parts: the exponential part caused by temperature recovery and the linear part caused by leak. With prior information obtained from samples, parameters of the exponential part can be identified precisely, and the temperature effect will be compensated before it fully recovers. To verify the effect of the temperature compensated method, chambers with different volumes are tested under various pressures and the experiments show that the improved method is faster with satisfactory precision, and an accuracy less than 0.25 cc min −1  can be achieved when the compensation time is proportional to four times the theoretical thermal-time constant. (paper)

  16. Signature modelling and radiometric rendering equations in infrared scene simulation systems

    CSIR Research Space (South Africa)

    Willers, CJ

    2011-09-01

    Full Text Available The development and optimisation of modern infrared systems necessitates the use of simulation systems to create radiometrically realistic representations (e.g. images) of infrared scenes. Such simulation systems are used in signature prediction...

  17. A radiometric mass flow probe for determining the screen overflow of potato harvesters

    International Nuclear Information System (INIS)

    Glaeser, M.

    1976-01-01

    A radiometric conveyor balance based on the principle of gamma attenuation is described. Being independent on the electric network, it is suitable for nonstationary operation. Cesium 137 is used as radiation source. Detection is performed through a special system of halogen and ordinary counters. First tests were made under field conditions in order to determine the passing mass (potatoes and soil) and to find out the sieving capacity of the potato harvesters. The maximum throughput is about 50 tons per hour. Potatoes and soil up to about 2 tons may be weighed by means of this balance with a relative error of +- 3.5 %. (author)

  18. Choosing of mode and calculation of multiple regression equation parameters in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Berezkin, V.V.; Lyubimova, S.V.; Svetajlo, Yu.N.; Shchekin, K.I.

    1978-01-01

    A method to derive multiple regression equations for X-ray radiometric analysis is described. Te method is realized in the form of the REGRA program in an algorithmic language. The subprograms included in the program are describe. In analyzing cement for Mg, Al, Si, Ca and Fe contents as an example, the obtainment of working equations in the course of calculations by the program is shown to simpliy the realization of computing devices in instruments for X-ray radiometric analysis

  19. Determination of reliability of express forecasting evaluation of radiometric enriching ability of non-ferrous ores

    International Nuclear Information System (INIS)

    Kirpishchikov, S.P.

    1991-01-01

    Use of the data of nuclear physical methods of sampling and logging enables to improve reliability of evaluation of radiometric enriching ability of ores, as well as to evaluate quantitatively this reliability. This problem may be solved by using some concepts of geostatistics. The presented results enable to conclude, that the data of nuclear-physical methods of sampling and logging can provide high reliability of evaluation of radiometric enriching ability of non-ferrous ores and their geometrization by technological types

  20. Radiometric geochronology of the Himalaya

    International Nuclear Information System (INIS)

    Saini, H.S.

    1982-01-01

    The radiometric age data obtained by different dating methods have been interpreted in terms of possible orogenic activities prevailing in the Himalaya. In general, the age data confirm four main events, the Precambrian, the Late Precambrian-Cambrian Assyntian (Caledonian), the Late Palaeozoic-Hercynian and the Late Cretaceous-Tertiary Himalayan orogeny. The mineral dates are particularly significant in delineating different phases of the last i.e. the Himalayan orogeny which indicates main activity of the young Himalayan metamorphism around 70 to 50 Ma and followed by a momentous phase of major uplift during 25 to 10 Ma, which was responsible for the rise of the deeper part of the Himalaya into great folds and thrust slices and the formation of nappe structures. (author)

  1. The Pelindaba facility for calibrating radiometric field instruments

    International Nuclear Information System (INIS)

    Corner, B.; Toens, P.D.; Van As, D.; Vleggaar, C.M.; Richards, D.J.

    1979-04-01

    The tremendous upsurge in uranium exploration activity, experienced in recent years, has made the need for the standardisation and calibration of radiometric field instruments apparent. In order to fulfill this need, construction of a calibration facility at the National Nuclear Research Centre, Pelindaba, was commenced in 1972 and has since been extended according the the requirements of the mining industry. The facility currently comprises 11 surface standard sources suitable for the calibration, in terms of radio-element concentration, of portable scintillometers and spectrometers, and single uranium and thorium model-borehole sources which make possible the accurate calibration of borehole logging instruments both for gross-count and spectrometric surveys. Portable potassium, uranium and thorium sources are also available for the purposes of establishing airborne-spectrometer stripping ratios. The relevant physico-chemical properties of the standards are presented in this report and calibration procedures and data reduction techniques recommended. Examples are given of in situ measurements, both on surface and down-the-hole, which show that the derived calibration constants yield radiometric grades which are, on average, accurate to within 5% of the true radio-element concentrations. A secondary facility comprising single borehole- and surface-uranium sources has also been constructed in Beaufort West in the southern Karoo [af

  2. A review of recent developments in radiometric calibration facilities

    International Nuclear Information System (INIS)

    Corner, B.

    1984-01-01

    Two new developments concerning radiometric calibration facilities are described in this presentation. The first is the result of the international programme for the monitoring and cross-reference of existing calibration facilities, sponsored by the International Atomic Energy Agency. The second development that is discussed concerns the accuracy of the stripping ratios derived at Pelindaba and has important implications for in situ assaying

  3. Radiometric titration of thallium(III) with EDTA

    International Nuclear Information System (INIS)

    Rao, V.R.S.; Pulla Rao, Ch.; Tataiah, G.

    1978-01-01

    Radioactive solutions containing very small amounts of thallium(III) can be determined by radiometric titration using ammonia as hydrolysing agent. Aqueous solution of thallium(I) (both inactive and radioactive) is treated with bromine water till the appearance of the brown colour of bromine, and the solution is warmed to 80 deg C to expel the excess bromine. By this procedure all thallium(I) is quantitatively oxidised to thallium(III). An aqueous solution of ammonia is added to precipitate thallium(III) as thallic oxide. It is then filtered, washed with water to free it from bromide and then dissolved in 2N HCl and the solution is then standardised. 2 ml of this solution is transferred to a 20 ml volumetric flask, 1 ml of radioactive thallium(III) solution to be standardised is added as well as incremental amounts of EDTA solution and mixed thoroughly. Uncomplexed thallium(III) is then precipitated by the addition of an ammonia solution and diluted to 20 ml. Required amount of this mixture is centrifuged. The beta activity of the supernatant aliquot is measured using a GM counter. Quantitative determination of Tl(III) in the range of 1-10 μM can be carried out. The interference of cations such as Au(III), iron(III), Ga(III) can be eliminated by pretreatment of the Tl(III) solution before carrying out radiometric titration. The results obtained are reproducible and accurate to +-3%. (T.I.)

  4. Radiometric survey in mammography: problems and challenges; Levantamento radiometrico em mamografia: problemas e desafios

    Energy Technology Data Exchange (ETDEWEB)

    Navarro, M.V.T.; Navarro, V.C.C.; Garcia, I.F.M.; Ferreira, M.J.; Macedo, E.M., E-mail: navarro@ifba.edu.br [Instituto Federal da Bahia (LABPROSAUD/IFBA), Salvador, BA (Brazil). Laboratorio de Produtos para a Saude

    2015-07-01

    In addition to being mandatory, the radiometric survey is a necessity, especially in the Brazilian reality with the construction of smaller and smaller rooms. However, calibration conditions, the instrumentation and its use, can produce underestimated factors. Measures made at Labprosaud/IFBA, with five different instruments and the ISO N 25 radiation quality, show the possibility of the values presented in the radiometric surveys are underestimated by up to 10 times. The results indicate the need for meters to be calibrated in ISO N qualities, in mammography energy range, in integrated dose mode and exposure times shorter or equal to 1 s. (author)

  5. Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques

    Energy Technology Data Exchange (ETDEWEB)

    Moody, J.S.; Brown, L.R.; Thieling, S.C.

    1995-12-31

    The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

  6. Blood culture cross contamination associated with a radiometric analyzer

    International Nuclear Information System (INIS)

    Griffin, M.R.; Miller, A.D.; Davis, A.C.

    1982-01-01

    During a 9-day period in August 1980 in a New Jersey hospital, three pairs of consecutively numbered blood cultures from different patients were identified as positive for the same organism, for each pair, both cultures were positive in the same atmosphere, both organisms had the same sensitivities, and the second of each pair grew at least 2 days after the first and was the only positive blood culture obtained from the patient. When the hospital laboratory discontinued use of its radiometric culture analyzer for 15 days, no more consecutive pairs of positive cultures occurred. Subsequent use of the machine for 9 days with a new power unit but the original circuit boards resulted in one more similar consecutive pair (Staphylococcus epidermidis). After replacement of the entire power unit, there were no further such pairs. Examination of the machine by the manufacturer revealed a defective circuit board which resulted in inadequate needle sterilization. Laboratories which utilize radiometric analyzers should be aware of the potential for cross contamination. Recognition of such events requires alert microbiologists and infection control practitioners and a record system in the bacteriology laboratory designed to identify such clusters

  7. Space Object Radiometric Modeling for Hardbody Optical Signature Database Generation

    Science.gov (United States)

    2009-09-01

    Introduction This presentation summarizes recent activity in monitoring spacecraft health status using passive remote optical nonimaging ...Approved for public release; distribution is unlimited. Space Object Radiometric Modeling for Hardbody Optical Signature Database Generation...It is beneficial to the observer/analyst to understand the fundamental optical signature variability associated with these detection and

  8. Detection of group D and viridans streptococci in blood by radiometric methods

    International Nuclear Information System (INIS)

    Beckwith, D.G.

    1979-01-01

    A prospective study was conducted to evaluate the radiometric detection of group D and viridans streptococci in blood, using three media preparations, Bactec 6A and 6B isotonic media and 8B hypertonic medium. All enterococci tested were detected by the 6A and 6B media. However, the 6A medium failed to detect 76% of the Streptococcus bovis isolates and 57% of the viridans streptococci, whereas all S. bovis isolates and 95% of the viridans streptococci were detected with the 6B formulation. No improvement in detection was noted in comparing the 6B and the 8B hypertonic media. The importance of adequate detection of this group of organisms, especially in patients with endocarditis, is discussed

  9. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1998-01-01

    Abstract: In the present paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or Rao’s efficient score test. The test is presented in the framework of a number of IRT models such as the Rasch model, the OPLM, the 2-parameter logistic model, the

  10. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1996-01-01

    In this paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or C. R. Rao's efficient score test. The test is presented in the framework of a number of item response theory (IRT) models such as the Rasch model, the one-parameter logistic model, the

  11. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    Directory of Open Access Journals (Sweden)

    Sigrid Roessner

    2011-06-01

    Full Text Available The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared and Hawk SWIR (Short Wave Infrared scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data.

  12. Radiometric calibration of digital cameras using neural networks

    Science.gov (United States)

    Grunwald, Michael; Laube, Pascal; Schall, Martin; Umlauf, Georg; Franz, Matthias O.

    2017-08-01

    Digital cameras are used in a large variety of scientific and industrial applications. For most applications, the acquired data should represent the real light intensity per pixel as accurately as possible. However, digital cameras are subject to physical, electronic and optical effects that lead to errors and noise in the raw image. Temperature- dependent dark current, read noise, optical vignetting or different sensitivities of individual pixels are examples of such effects. The purpose of radiometric calibration is to improve the quality of the resulting images by reducing the influence of the various types of errors on the measured data and thus improving the quality of the overall application. In this context, we present a specialized neural network architecture for radiometric calibration of digital cameras. Neural networks are used to learn a temperature- and exposure-dependent mapping from observed gray-scale values to true light intensities for each pixel. In contrast to classical at-fielding, neural networks have the potential to model nonlinear mappings which allows for accurately capturing the temperature dependence of the dark current and for modeling cameras with nonlinear sensitivities. Both scenarios are highly relevant in industrial applications. The experimental comparison of our network approach to classical at-fielding shows a consistently higher reconstruction quality, also for linear cameras. In addition, the calibration is faster than previous machine learning approaches based on Gaussian processes.

  13. Reduction of Radiometric Miscalibration—Applications to Pushbroom Sensors

    Science.gov (United States)

    Rogaß, Christian; Spengler, Daniel; Bochow, Mathias; Segl, Karl; Lausch, Angela; Doktor, Daniel; Roessner, Sigrid; Behling, Robert; Wetzel, Hans-Ulrich; Kaufmann, Hermann

    2011-01-01

    The analysis of hyperspectral images is an important task in Remote Sensing. Foregoing radiometric calibration results in the assignment of incident electromagnetic radiation to digital numbers and reduces the striping caused by slightly different responses of the pixel detectors. However, due to uncertainties in the calibration some striping remains. This publication presents a new reduction framework that efficiently reduces linear and nonlinear miscalibrations by an image-driven, radiometric recalibration and rescaling. The proposed framework—Reduction Of Miscalibration Effects (ROME)—considering spectral and spatial probability distributions, is constrained by specific minimisation and maximisation principles and incorporates image processing techniques such as Minkowski metrics and convolution. To objectively evaluate the performance of the new approach, the technique was applied to a variety of commonly used image examples and to one simulated and miscalibrated EnMAP (Environmental Mapping and Analysis Program) scene. Other examples consist of miscalibrated AISA/Eagle VNIR (Visible and Near Infrared) and Hawk SWIR (Short Wave Infrared) scenes of rural areas of the region Fichtwald in Germany and Hyperion scenes of the Jalal-Abad district in Southern Kyrgyzstan. Recovery rates of approximately 97% for linear and approximately 94% for nonlinear miscalibrated data were achieved, clearly demonstrating the benefits of the new approach and its potential for broad applicability to miscalibrated pushbroom sensor data. PMID:22163960

  14. Differential Prediction Generalization in College Admissions Testing

    Science.gov (United States)

    Aguinis, Herman; Culpepper, Steven A.; Pierce, Charles A.

    2016-01-01

    We introduce the concept of "differential prediction generalization" in the context of college admissions testing. Specifically, we assess the extent to which predicted first-year college grade point average (GPA) based on high-school grade point average (HSGPA) and SAT scores depends on a student's ethnicity and gender and whether this…

  15. Radiometric installations for automatic control of industrial processes and some possibilities of the specialized computers application

    International Nuclear Information System (INIS)

    Kuzino, S.; Shandru, P.

    1979-01-01

    It is noted that application of radioisotope devices in circuits for automation of some industrial processes permits to obtain the on-line information about some parameters of these processes. This information being passed to a computer, controlling the process, permits to obtain and maintain some optimum technological perameters of this process. Some elements of the automation stem projecting are given from the poin of wiev of the radiometric devices tuning, calibration of the radiometric devices with the purpose to get a digital answer in the on-line regime with the preset accuracy and thrustworthyness levels for supplying them to the controlling computer; determination of the system's reaction on the base of the preset statistical criteria; development, on the base of the data obtained from the computer, of an algorithm for the functional checking of radiometric devices' characteristics, - stability and reproductibility of readings in the operation regime as well as determination of the value threshold of an answer, depending on the measured parameter [ru

  16. Radiometric densimeter for measuring and automatic control of liquid density

    International Nuclear Information System (INIS)

    Wajs, J.

    1982-01-01

    A performance rule of the radiometric densimeter produced by ''POLON ''Works is presented. A simplified analysis of the correction of density indication changes due to liquid temperature variations is described. A method of replacing the measuring pipe carrying the liquid being measured by suitable standards is given. The method is for automatic systems control. (A.S.)

  17. Geologic and radiometric study in the Picacho, Arizpe's Municipality, Sorora (Mexico) area

    International Nuclear Information System (INIS)

    Garcia y Barragan, J.C.

    1975-01-01

    This research work was aimed chiefly at studying the geology and radiometry of the El Picacho area in order to establish its uranium mineralization potential. Another purpose was to ascertain the factors favouring deposition of radioactive material in areas bordering on the Sierra del Manzanal, where the work was carried out. Detailed geological-radiometric surveys were made, both inside the El Picacho mine and at the surface. The geological surveys were carried out by means of compass bearings and stadia, while scintillometers and spectrometers were used for the radiometric studies. The work was supported by a general geological exploration of the central part of the Serra del Manzanal. To ascertain the radiometric anomalies, the distribution of the population of values was determined by statistical methods, the frequency, cumulative frequency and frequency percentage being evaluated for that purpose. The geological survey at the El Picacho mine revealed a group of fractures enclosing the following minerals: torbernite, iriginite and autunite. These fractures are no thicker than 5 cm and tend to wedge out after 3 meters. Primary uraniferous ore is likely to be found in this zone, so surveys based on (a) radon gas emanometry and (b) sediment geochemistry in the Siera del Manzanal are recommended. The basic data relating to this area could be supplemented by mineragraphic and X-ray studies, which would provide a fuller picture of the class of mineralogical species and of the paragenesis of radioactive material presnent in the zone. (author)

  18. Relative Radiometric Normalization and Atmospheric Correction of a SPOT 5 Time Series

    Directory of Open Access Journals (Sweden)

    Matthieu Rumeau

    2008-04-01

    Full Text Available Multi-temporal images acquired at high spatial and temporal resolution are an important tool for detecting change and analyzing trends, especially in agricultural applications. However, to insure a reliable use of this kind of data, a rigorous radiometric normalization step is required. Normalization can be addressed by performing an atmospheric correction of each image in the time series. The main problem is the difficulty of obtaining an atmospheric characterization at a given acquisition date. In this paper, we investigate whether relative radiometric normalization can substitute for atmospheric correction. We develop an automatic method for relative radiometric normalization based on calculating linear regressions between unnormalized and reference images. Regressions are obtained using the reflectances of automatically selected invariant targets. We compare this method with an atmospheric correction method that uses the 6S model. The performances of both methods are compared using 18 images from of a SPOT 5 time series acquired over Reunion Island. Results obtained for a set of manually selected invariant targets show excellent agreement between the two methods in all spectral bands: values of the coefficient of determination (r² exceed 0.960, and bias magnitude values are less than 2.65. There is also a strong correlation between normalized NDVI values of sugarcane fields (r² = 0.959. Despite a relative error of 12.66% between values, very comparable NDVI patterns are observed.

  19. Spectrometric devices of itinerant radiometric laboratory

    International Nuclear Information System (INIS)

    Dolgirev, E.I.; Moroz, G.L.; Shchedrin, D.A.

    1978-01-01

    Scintillation gamma-spectrometer is described designed for mobile radiometric laboratory for individual monitoring of internal γ-radiation of members of the general population and service personnel as well as for analysis of the isotopic composition of radiocontaminants in the environment. Description and technical features of device are given. The detection unit consists of detectors made on the basis of NaI(Tl) monocrystals 63 x 63 mm in size. The unit permits measurement of various levels of gamma-emitting nuclides throughout the body and in the thyroid and lungs of man. Provision is made for measuring samples with high specific activities (more than 10 -5 Cu/g) and for examining individuals having high levels of incorporated radionuclides

  20. Radiorespirometric testing of antibiotic sensitivity in urinary tract infections: concise communication

    International Nuclear Information System (INIS)

    Singh, K.T.; Ganatra, R.D.; Shah, D.H.; Shanta, M.; Nimbkar, Y.S.; Gaitonde, B.B.; Dudani, R.A.; Jadav, S.K.; Acharya, V.N.

    1980-01-01

    A radiometric method, based on inhibition of 14 CO 2 release from bacterial metabolism of C-14-labeled glucose, was applied to test the susceptibility of urinary organisms to antibiotics. The testing was also carried out by the routine disc diffusion method after isolation of the organisms. Results of susceptibility to antibiotics could be obtained within 2 to 4 hr by the radiometric technique, compared with the 48 hr required for the disc method

  1. Detection and recovery of mycobacteria by a radiometric procedure

    International Nuclear Information System (INIS)

    Takahashi, H.; Foster, V.

    1983-01-01

    During a 6-month period, 5,375 clinical specimens were cultured on Middlebrook-Cohn 7H10 medium, on Lowenstein-Jensen medium, and in Middlebrook 7H12 medium containing [ 14 C]palmitic acid. More mycobacteria were recovered when all three media were used than when either the conventional method with 7H10 agar and Lowenstein-Jensen slants or the radiometric method with 7H12 broth was used alone

  2. A practical intercomparison of non-radiometric methods for the determination of low levels of radionuclides

    International Nuclear Information System (INIS)

    McMahon, A.W.

    1991-01-01

    Non-Radiometric, methods of elemental analysis have been assessed as alternatives to radiometric methods for the determination of low levels of radionuclides. The methods have been assessed in a practical intercomparison, using a set of samples containing known, low levels of analytes in a variety of matrices. It was found that all of the methods considered have a role to play and are to some extent complementary in terms of cost, rate of sample throughput, elemental coverage, imaging capability sensitivity and quantitative capabilities. Techniques based on mass spectrometry have most to offer in this application, allowing sensitive isotope specific determinations. (author)

  3. An Assessment of Polynomial Regression Techniques for the Relative Radiometric Normalization (RRN of High-Resolution Multi-Temporal Airborne Thermal Infrared (TIR Imagery

    Directory of Open Access Journals (Sweden)

    Mir Mustafizur Rahman

    2014-11-01

    Full Text Available Thermal Infrared (TIR remote sensing images of urban environments are increasingly available from airborne and satellite platforms. However, limited access to high-spatial resolution (H-res: ~1 m TIR satellite images requires the use of TIR airborne sensors for mapping large complex urban surfaces, especially at micro-scales. A critical limitation of such H-res mapping is the need to acquire a large scene composed of multiple flight lines and mosaic them together. This results in the same scene components (e.g., roads, buildings, green space and water exhibiting different temperatures in different flight lines. To mitigate these effects, linear relative radiometric normalization (RRN techniques are often applied. However, the Earth’s surface is composed of features whose thermal behaviour is characterized by complexity and non-linearity. Therefore, we hypothesize that non-linear RRN techniques should demonstrate increased radiometric agreement over similar linear techniques. To test this hypothesis, this paper evaluates four (linear and non-linear RRN techniques, including: (i histogram matching (HM; (ii pseudo-invariant feature-based polynomial regression (PIF_Poly; (iii no-change stratified random sample-based linear regression (NCSRS_Lin; and (iv no-change stratified random sample-based polynomial regression (NCSRS_Poly; two of which (ii and iv are newly proposed non-linear techniques. When applied over two adjacent flight lines (~70 km2 of TABI-1800 airborne data, visual and statistical results show that both new non-linear techniques improved radiometric agreement over the previously evaluated linear techniques, with the new fully-automated method, NCSRS-based polynomial regression, providing the highest improvement in radiometric agreement between the master and the slave images, at ~56%. This is ~5% higher than the best previously evaluated linear technique (NCSRS-based linear regression.

  4. Preliminary Evaluation of GAOFEN-3 Polarimetric and Radiometric Accuracy by Corner Reflectors in Inner Mongolia

    Science.gov (United States)

    Shi, L.; Ding, X.; Li, P.; Yang, J.; Zhao, L.; Yang, L.; Chang, Y.; Yan, L.

    2018-04-01

    On August 10, 2016, China launched its first C-band full polarimetric radar satellite, named Gaofen-3 (GF-3), for urban and agriculture monitoring, landslide detection, ocean applications, etc. According to the design specification, GF-3 is expected to work at -35 dB crosstalk and 0.5 dB channel imbalance, with less than 10 degree error. The absolute radiometric bias is expected to be less than 1.5 dB in a single scene and 2.0 dB when operating for a long time. To complete the calibration and evaluation, the Institute of Electronics, Chinese Academy Sciences (IECAS) built a test site at Inner Mongolia, and deployed active reflectors (ARs) and trihedral corner reflectors (CRs) to solve and evaluate the hardware distortion. To the best of the authors' knowledge, the product accuracy of GF-3 has not been comprehensively evaluated in any open publication. The remote sensing community urgently requires a detailed report about the product accuracy and stability, before any subsequent application. From June to August of 2017, IECAS begun its second round ground campaign and deployed 10 CRs to evaluate product distortions. In this paper, we exploit Inner Mongolia CRs to investigate polarimetric and radiometric accuracy of QPSI I Stripmap. Although some CRs found fall into AR side lobe, the rest CRs enable us to preliminarily evaluate the accuracy of some special imaging beams. In the experimental part, the image of July 6, 2017 was checked by 5 trihedral CRs and the integration estimation method demonstrated the crosstalk varying from -42.65 to -32.74 dB, and the channel imbalance varying from -0.21 to 0.47 with phase error from -2.4 to 0.2 degree. Comparing with the theoretical radar cross-section of 1.235 m trihedral CR, i.e. 35 dB, the radiometric error varies about 0.20 ± 0.29 dB in HH channel and 0.40 ± 0.20 dB in VV channel.

  5. Rain attenuation studies from radiometric and rain DSD measurements at two tropical locations

    Science.gov (United States)

    Halder, Tuhina; Adhikari, Arpita; Maitra, Animesh

    2018-05-01

    Efficient use of satellite communication in tropical regions demands proper characterization of rain attenuation, particularly, in view of the available popular propagation models which are mostly based on temperate climatic data. Thus rain attenuations at frequencies 22.234, 23.834 and 31.4/30 GHz over two tropical locations Kolkata (22.57°N, 88.36°E, India) and Belem (1.45°S, 48.49° W, Brazil), have been estimated for the year 2010 and 2011, respectively. The estimation has been done utilizing ground-based disdrometer observations and radiometric measurements over Earth-space path. The results show that rain attenuation estimations from radiometric data are reliable only at low rain rates (measurements show good agreement with the ITU-R model, even at high rain rates (upto100 mm/h). Despite having significant variability in terms of drop size distribution (DSD), the attenuation values calculated from DSD data (disdrometer measurements) at Kolkata and Belem differ a little for the rain rates below 30 mm/h. However, the attenuation values, obtained from radiometric measurements at the two places, show significant deviations ranging from 0.54 dB to 3.2 dB up to a rain rate of 30 mm/h, on account of different rain heights, mean atmospheric temperatures and climatology of the two locations.

  6. Stability test for a parabolic partial differential equation

    NARCIS (Netherlands)

    Vajta, Miklos

    2001-01-01

    The paper describes a stability test applied to coupled parabolic partial differential equations. The PDE's describe the temperature distribution of composite structures with linear inner heat sources. The distributed transfer functions are developed based on the transmission matrix of each layer.

  7. Evaluation of element migration from food plastic packagings into simulated solutions using radiometric method

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez; Saiki, Mitiko; Wiebeck, Helio

    2005-01-01

    In the present study a radiometric method was established to determine the migration of elements from food plastic packagings to a simulated acetic acid solution. This radiometric method consisted of irradiating plastic samples with neutrons at IEA-R1 nuclear reactor for a period of 16 hours under a neutron flux of 10 12 n cm -2 s -1 and, then to expose them to the element migration into a simulated solution. The radioactivity of the activated elements transferred to the solutions was measured to evaluate the migration. The experimental conditions were: time of exposure of 10 days at 40 deg C and 3% acetic acid solution was used as simulated solution, according to the procedure established by the National Agency of Sanitary Monitoring (ANVISA). The migration study was applied for plastic samples from soft drink and juice packagings. The results obtained indicated the migration of elements Co, Cr and Sb. The advantage of this methodology was no need to analyse the blank of simulantes, as well as the use of high purity simulated solutions. Besides, the method allows to evaluate the migration of the elements into the food content instead of simulated solution. The detention limits indicated high sensitivity of the radiometric method. (author)

  8. Radiometric, SEM and XRD investigation of the Chituc black sands, southern Danube Delta, Romania

    International Nuclear Information System (INIS)

    Margineanu, R.M.; Blebea-Apostu, Ana-Maria; Celarel, Aurelia; Gomoiu, Claudia-Mariana; Costea, C.; Dumitras, Delia; Ion, Adriana; Duliu, O.G.

    2014-01-01

    The black sand of the Chituc marine sand bank, northern of the city of Navodari (Romania), presents anomalous high radioactivity. Field measurements recorded in some places dose rate up to 200 nSv/h, significantly overpassing the average value of 44 ± 20 nSv/h along the entire Southern sector of Romanian Black Sea shore. Gamma ray spectrometry performed on both Slanic-Prahova Underground Low Background Laboratory and Geological Institute of Romania Radiometric Facilities showed with clarity the dominance of 228 Ac radioisotope in the 50 microns fraction together with the 226 Ra and traces of 40 K. No significant amount of anthropogenic 137 Cs was identified. Based on radiometric as well as on SEM–EDAX and XRD determinations we come to the conclusion that the evidenced radioactivity could be attributed to both uranium and thorium series in the zircon and monazite fractions and to a lesser extent to potassium in the feldspars. - Highlights: • High background radioactivity (up to 200 nSv/h) evidenced. • Radiometric measurements showed a maximum radioactivity of U and Th confined to 50–100 μm fraction. • XRD and SEM–EDAX data revealed the presence of k-feldspars, ilmenite, zircone, monazite and garnets

  9. Geologic and radiometric study of the Santa Rosalia area, Arizpe Department, Sonora Mexico

    International Nuclear Information System (INIS)

    Sanchez M, C.A.

    1977-01-01

    The importance of the radiometrical anomaly, discovered in the Santa Rosalia area, Arizpe Department, Sonota, is defined in this study through topographical and geological surveying of the area by the outline and systematical survey of rocks for sampling and registration of the radioactivity. Two radioactive anomalies were defined and called IIIA and IIIB, identifying the existence of secondary uranium minerals (Torbernite) in the IIIB anomaly. According to the results of the work which was carried out we can't deduce that both localities present signs of the existence of important uranium concentrations. We can conclude that the presence of uranium minerals obliges us to realize a more detailed exploration, suggesting the opening of little excavations and ditches and stretching out of the geochemical, geological and radiometrical exploration to adjacent areas. (author)

  10. Geometric Calibration and Radiometric Correction of LiDAR Data and Their Impact on the Quality of Derived Products

    Directory of Open Access Journals (Sweden)

    Wai-Yeung Yan

    2011-09-01

    Full Text Available LiDAR (Light Detection And Ranging systems are capable of providing 3D positional and spectral information (in the utilized spectrum range of the mapped surface. Due to systematic errors in the system parameters and measurements, LiDAR systems require geometric calibration and radiometric correction of the intensity data in order to maximize the benefit from the collected positional and spectral information. This paper presents a practical approach for the geometric calibration of LiDAR systems and radiometric correction of collected intensity data while investigating their impact on the quality of the derived products. The proposed approach includes the use of a quasi-rigorous geometric calibration and the radar equation for the radiometric correction of intensity data. The proposed quasi-rigorous calibration procedure requires time-tagged point cloud and trajectory position data, which are available to most of the data users. The paper presents a methodology for evaluating the impact of the geometric calibration on the relative and absolute accuracy of the LiDAR point cloud. Furthermore, the impact of the geometric calibration and radiometric correction on land cover classification accuracy is investigated. The feasibility of the proposed methods and their impact on the derived products are demonstrated through experimental results using real data.

  11. Transillumination test: A bedside aid for differentiating meningocele from myelomeningocele: Point of care testing

    Directory of Open Access Journals (Sweden)

    Aakash Pandita

    2015-01-01

    Full Text Available Transillumination test is a bedside and simple technique to illuminate the body cavity by transmission of light through the cavity. Transillumination test is used in a variety of conditions like hydrocele, Hydrocephalus, pneumoperitonium and pneumothorax in neonatology. We describe use of transillumination for differentiating meningocele and myelomeningocele.

  12. The use of radiometric-logging techniques to determine uranium grade in certain mineralised Karoo boreholes

    International Nuclear Information System (INIS)

    Corner, B.; De Beer, G.P.

    1976-05-01

    During the period September-October 1975, 22 mineralised boreholes in nine different Karoo uranium occurrences were logged radiometrically with the aim of determining to what accuracy the actual uranium grade could be predicted from the gamma logs. The true uranium grades of the mineralised zones logged were known from existing chemical analyses. The results showed that the uranium grades could be predicted to an accuracy of better than 10% through the use of gamma-logging equipment calibrated at Pelindaba, provided that the ore was in equilibrium and that little or no thorium was present. Disequilibrium is, however, prevalent in the Karoo, and in the holes logged it occurred by depletion of uranium relative to its gamma-emitting daughter products. Such effects were mostly confined to the zone above the water table, and it is concluded that for Karoo-type occurrences, the high radiometric background levels observed over extended distances in some boreholes were indicative of radon-gas buildup, and hence of disequilibrium. It is further concluded that radiometric borehole logging can largely replace chemical analyses in the determination of uranium grade for ore-reserve calculations, although chemical checks for disequilibrium would always be necessary [af

  13. Synoptic view of the different domains of application of airborne radiometric and spectrometric surveys in egypt

    International Nuclear Information System (INIS)

    Fouad, K.M.

    1998-01-01

    Airborne radiometric survey has been applied for more than three decades in egypt. Experience gained from the acquired data over different geological environments has revealed the importance of this geophysical tool in: 1. disclosure of anomalies of potential uranium deposits, 2. geological mapping, 3. environmental monitoring of natural radiometric background around nuclear facilities, as well as the detection of nuclear fallout resulting from local or foreign nuclear activities. The advent of recording of the discriminated gamma ray energies in the airborne 256-channel spectrometer has eventually resulted in the quantitative detection of uranium, thorium, and potassium and their elemental ratios in the rocks. This has greatly widened the scope of geophysical and geochemical application. When this type is coupled with airborne magnetometry, the geological and structural configuration is appreciably revealed in three dimensions. The important role played by the statistical method of analysis is also shown. Case histories from the eastern desert, and sinai peninsula, are exhibited to help manifest the wide variety of applications of radiometric and spectrometric surveys

  14. Radiometric surveys in underground environment

    Science.gov (United States)

    Bochiolo, Massimo; Chiozzi, Paolo; Verdoya, Massimo; Pasquale, Vincenzo

    2010-05-01

    Due to their ability to travel through the air for several metres, gamma-rays emitted from natural radioactive elements can be successfully used in surveys carried out both with airborne and ground equipments. Besides the concentration of the radio-elements contained in rocks and soils and the intrinsic characteristics of the gamma-ray detector, the detected count rate depends on the solid angle around the spectrometer. On a flat outcrop, ground spectrometry detects the radiation ideally produced by a cylindrical mass of rock of about two metres in diameter and thickness of about half a meter. Under these geometrical conditions, the natural radioactivity can be easily evaluated. With operating conditions different from the standard ones, such as at the edge of an escarpment, the count rate halves because of the missing material, whereas in the vicinity of a rock wall the count rate will increase. In underground environment, the recorded count rate may even double and the in situ assessment of the concentration of radio-elements may be rather difficult, even if the ratios between the different radio-elements may not be affected. We tested the applicability of gamma-ray spectrometry for rapid assessment of the potential hazard levels related to radon and radiation dose rate in underground environment. A mine shaft, located in a zone of uranium enrichment in Liguria (Italy), has been investigated. A preliminary ground radiometric survey was carried out to define the extent of the ore deposit. Then, the radiometric investigation was focussed on the mine shaft. Due to rock mass above the shaft vault, the background gamma radiation can be considered of negligible influence on measurements. In underground surveys, besides deviations from a flat geometry, factors controlling radon exhalation, emanation and stagnation, such as fractures, water leakage and the presence of ventilation, should be carefully examined. We attempted to evaluate these control factors and collected

  15. Multipurpose radiometric equipment provided with a microcontroller for use in industrial applications (e.g., measurements of level, density, thickness, etc.)

    International Nuclear Information System (INIS)

    Kluger, A.; Popescu, C.; Patrascu, S.

    1998-01-01

    The goal of this research was to modernize the radiometric equipment used for the control and automation of technological processes. A microcontroller-equipped electronic block was designed and realized, capable of performing all the tasks of a radiometric system, regardless of the application range (i.e. measurement of density, thickness, level, composition, etc.) or the detector type employed. In this work, the experimental model for the multipurpose radiometric equipment was devised. The electronic unit was designed using a high performance controller 80C552 and was provided with low-power transceivers for RS-232 and RS-485 communication with a PC. The results of the measured parameters are displayed using a graphic liquid crystal display, LCD G 242 C, that allows both graphics and character display. (authors)

  16. Applications of high resolution airborne magnetic and radiometric data in the Barberton Greenstone Belt of South Africa

    International Nuclear Information System (INIS)

    Moore, C.

    1994-01-01

    We investigated the data obtained from a geophysical survey of the Greenstone Belt in the Barberton mountain land in the Transvaal, South Africa. A geological map is derived from the airborne magnetic and radiometric survey which differs significantly from the published geological map, particularly in the eastern are of the survey. There is no evidence contained within the geological data to suggest that the Greenstone Belt extends to a depth greater that 3 kilometers. The major geological constituents of the Barberton mountain land displays distinctive and diagnostic radiometric signatures, enabling accurate lithologic discrimination. 63 refs

  17. Effect of Differential Item Functioning on Test Equating

    Science.gov (United States)

    Kabasakal, Kübra Atalay; Kelecioglu, Hülya

    2015-01-01

    This study examines the effect of differential item functioning (DIF) items on test equating through multilevel item response models (MIRMs) and traditional IRMs. The performances of three different equating models were investigated under 24 different simulation conditions, and the variables whose effects were examined included sample size, test…

  18. Statistical Techniques Applied to Aerial Radiometric Surveys (STAARS): cluster analysis. National Uranium Resource Evaluation

    International Nuclear Information System (INIS)

    Pirkle, F.L.; Stablein, N.K.; Howell, J.A.; Wecksung, G.W.; Duran, B.S.

    1982-11-01

    One objective of the aerial radiometric surveys flown as part of the US Department of Energy's National Uranium Resource Evaluation (NURE) program was to ascertain the regional distribution of near-surface radioelement abundances. Some method for identifying groups of observations with similar radioelement values was therefore required. It is shown in this report that cluster analysis can identify such groups even when no a priori knowledge of the geology of an area exists. A method of convergent k-means cluster analysis coupled with a hierarchical cluster analysis is used to classify 6991 observations (three radiometric variables at each observation location) from the Precambrian rocks of the Copper Mountain, Wyoming, area. Another method, one that combines a principal components analysis with a convergent k-means analysis, is applied to the same data. These two methods are compared with a convergent k-means analysis that utilizes available geologic knowledge. All three methods identify four clusters. Three of the clusters represent background values for the Precambrian rocks of the area, and one represents outliers (anomalously high 214 Bi). A segmentation of the data corresponding to geologic reality as discovered by other methods has been achieved based solely on analysis of aerial radiometric data. The techniques employed are composites of classical clustering methods designed to handle the special problems presented by large data sets. 20 figures, 7 tables

  19. Radiometric method for the rapid detection of Leptospira organisms

    International Nuclear Information System (INIS)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-01-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with 14 C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques

  20. Processing data collected from radiometric experiments by multivariate technique

    International Nuclear Information System (INIS)

    Urbanski, P.; Kowalska, E.; Machaj, B.; Jakowiuk, A.

    2005-01-01

    Multivariate techniques applied for processing data collected from radiometric experiments can provide more efficient extraction of the information contained in the spectra. Several techniques are considered: (i) multivariate calibration using Partial Least Square Regression and Artificial Neural Network, (ii) standardization of the spectra, (iii) smoothing of collected spectra were autocorrelation function and bootstrap were used for the assessment of the processed data, (iv) image processing using Principal Component Analysis. Application of these techniques is illustrated on examples of some industrial applications. (author)

  1. A novel solution for car traffic control based on radiometric microwave devices

    Science.gov (United States)

    Soldovieri, Francesco; Denisov, Alexander; Speziale, Victor

    2014-05-01

    The significant problem of traffic in big cities, connected with huge and building up quantity of automobile cars, demands for novel strategies, based on nonconventional solutions, in order to improve system traffic control, especially at crossroads. As well known, the usual solution is based on the time relay, which requires the installation of a fixed traffic interval (signal light switching) at a crossroad; this solution is low cost, but does not account for the actual traffic conditions. Therefore, in the recent years, attention is towards to new designs, where the monitoring of the and control of traffic is carried out by using various methods including, optical, the infrared, magnetic, radar tracking, acoustical ones. In this work, we discuss the deployment of high sensitivity radiometric systems and radiometers(sensor) in the microwave range [1, 2]. In fact, the radiometer as "sensor" can provide an always updated information about the car traffic in any weather condition and in absence or low visibility conditions. In fact, the radiometric sensor detects the cars thanks to the different behavior of the car roofs which reflect the cold sky whereas the road asphalt is visible as warm object (at around outside temperature). [1] A. G. Denisov, V. P. Gorishnyak, S. E. Kuzmin et al., "Some experiments concerning resolution of 32 sensors passive 8mm wave imaging system," in Proceedings of the International Symposium on Space Terahertz Technology (ISSTT '09), Charlottesville, Va, USA, April 2009. [2] F. Soldovieri, A. Natale, V. Gorishnyak, A. Pavluchenko, A. Denisov, and L. Chen, "Radiometric Imaging for Monitoring and Surveillance Issues," International Journal of Antennas and Propagation, vol. 2013, Article ID 272561, 8 pages, 2013. doi:10.1155/2013/272561.

  2. Gamma radiometric survey of Jamaica

    International Nuclear Information System (INIS)

    Lalor, G.C.; Robotham, H.; Miller, J.M.; Simpson, P.R.

    1989-01-01

    The results of a total gamma radiometric survey of Jamaica, carried out with car-borne instrumentation, are presented and the data compared with the contents of potassium, thorium and uranium in rocks and in surface (soil, stream-sediment, pan concentrate and water) samples obtained at six sites selected to be representative of the principal rock types and surface environments of Jamaica. The work formed part of an orientation study for a regional geochemical survey of the CARICOM countries of the Caribbean. The initial results indicate that enhanced gamma activity is correlated with enrichment in uranium and thorium, but not potassium, in terra rossa soils and/or bauxite deposits in limestone. Elsewhere, gamma levels are increased on the Above Rocks Cretaceous basement Inlier, where they correlate generally with the presence of volcanogenic sediments and a granodiorite intrusion. The lowest radioactivity was recorded in the vicinity of ultrabasic rocks in the Blue Mountains Inlier. (author)

  3. Comparative study of gamma-ray logging and radiometric core assay of boreholes in block-I of Tummalapalle area, Cuddapah District, Andhra Pradesh using statistical methods

    International Nuclear Information System (INIS)

    Sreenivasa Reddy, M.; Mandal, G.; Bhaumik, B.K.

    2012-01-01

    A comparative study has been carried out between gamma-ray logging and radiometric core assay data of boreholes in Block-I of Tummalapalle area, South Cuddapah Basin, Andhra Pradesh using statistical methods. The product of average grade (in %eU 3 O 8 ) and thickness (in m) of uranium mineralization has been used for this purpose. The outcome of statistical analysis revealed a strong relation between gamma-ray logging and radiometric core assay data. Slope of the line is close to 1.0 and intercept is not different from 0.0. It ensures homogeneity of uranium ore distribution in the host rock. The calculated value from t-test is well within the limit and ensures the negligibility in the difference of means. This indicates that either of the data can be used for ore reserve calculation. (author)

  4. Impact of the cameras radiometric resolution on the accuracy of determining spectral reflectance coefficients

    Science.gov (United States)

    Orych, A.; Walczykowski, P.; Jenerowicz, A.; Zdunek, Z.

    2014-11-01

    Nowadays remote sensing plays a very important role in many different study fields, i.e. environmental studies, hydrology, mineralogy, ecosystem studies, etc. One of the key areas of remote sensing applications is water quality monitoring. Understanding and monitoring of the water quality parameters and detecting different water contaminants is an important issue in water management and protection of whole environment and especially the water ecosystem. There are many remote sensing methods to monitor water quality and detect water pollutants. One of the most widely used method for substance detection with remote sensing techniques is based on usage of spectral reflectance coefficients. They are usually acquired using discrete methods such as spectrometric measurements. These however can be very time consuming, therefore image-based methods are used more and more often. In order to work out the proper methodology of obtaining spectral reflectance coefficients from hyperspectral and multispectral images, it is necessary to verify the impact of cameras radiometric resolution on the accuracy of determination of them. This paper presents laboratory experiments that were conducted using two monochromatic XEVA video sensors (400-1700 nm spectral data registration) with two different radiometric resolutions (12 and 14 bits). In view of determining spectral characteristics from images, the research team used set of interferometric filters. All data collected with multispectral digital video cameras were compared with spectral reflectance coefficients obtained with spectroradiometer. The objective of this research is to find the impact of cameras radiometric resolution on reflectance values in chosen wavelength. The main topic of this study is the analysis of accuracy of spectral coefficients from sensors with different radiometric resolution. By comparing values collected from images acquired with XEVA sensors and with the curves obtained with spectroradiometer it

  5. Geological and radiometric study of the anomaly ''San Martin'' municipality of Sierra Mojada, Coahuila

    International Nuclear Information System (INIS)

    Ibarra Mora, P.

    1975-01-01

    When it first became known that there were uranium ores at the mine known as San Martin (72 hectares, Mining Agency, Sabinas, Mexico), exploration work was started with the sinking of two wells at the sites of maximum radiometric intensity. A short while afterwards, however, this work was suspended. In 1974, the work required for evaluation of the locality was begun. Geological and radiometric studies carried out both at the surface and underground pointed to the conclusion that the San Martin anomaly, down to the depth explored (40 metres), is a stockwork-type deposit or a tabular seam of the fissure type. It was concluded that in view of the grades obtained (0.0227%U 3 O 6 ) down to 40 metres, the deposit cannot be considered of econimic importance at the present time. (author)

  6. Radiometric sorting of Rio Algom uranium ore

    International Nuclear Information System (INIS)

    Cristovici, M.A.

    1983-11-01

    An ore sample of about 0.2 percent uranium from Quirke Mine was subjected to radiometric sorting by Ore Sorters Limited. Approximately 60 percent of the sample weight fell within the sortable size range: -150 + 25 mm. Rejects of low uranium content ( 2 (2 counts/in 2 ) but only 7.6 percent of the ore, by weight, was discarded. At 0.8-0.9 counts/cm 2 (5-6 counts/in 2 ) a significant amount of rejects was removed (> 25 percent) but the uranium loss was unacceptably high (7.7 percent). Continuation of the testwork to improve the results is proposed by trying to extend the sortable size range and to reduce the amount of fines during crushing

  7. Process system of radiometric and magnetometric aerial information

    International Nuclear Information System (INIS)

    Bazua Rueda, L.F.

    1985-01-01

    The author has been working first in the National Institute of Nuclear Energy (Mexico) and then in URAMEX (Uranio Mexicano) since 1975 to 1983, integrated to radiometric and magnetometric aerial prospecting projects in computerized processing of information aspects. During this period the author participated in the work out of computing systems, information processing and mathematical procedures definition for the geophysical reduction of the calibration equipment data. With cumulated experience, in this thesis are presented aspects concerning to management and operation of computerized processing of information systems. Operation handbooks of the majority of modules are presented. Program lists are not included. (Author)

  8. Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source

    Science.gov (United States)

    Coles, James B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Porter, Michael D.; Green, Robert O.; Nolte, Scott H.; Hernandez, Marco A.; Knoll, Linley A.

    2013-01-01

    The Onboard Calibration (OBC) source incorporates a medical/scientific-grade halogen source with a precisely designed fiber coupling system, and a fiber-based intensity-monitoring feedback loop that results in radiometric and spectral stabilities to within less than 0.3 percent over a 15-hour period. The airborne imaging spectrometer systems developed at the Jet Propulsion Laboratory incorporate OBC sources to provide auxiliary in-use system calibration data. The use of the OBC source will provide a significant increase in the quantitative accuracy, reliability, and resulting utility of the spectral data collected from current and future imaging spectrometer instruments.

  9. Device for continuous radiometric determination of the calcium and iron content in raw slurry for cement

    International Nuclear Information System (INIS)

    Wasilewska, M.; Ostachowicz, J.; Lankosz, M.; Molodynska, W.

    1975-01-01

    The characteristic iron and calcium-K series were excited using a Cd-109 isotope source. In order to determine the calcium and iron content in dry slurry, the Compton-effect scattered radiation of the Cd-109 source in the sample was used. A numerical process was worked out which allowed the elimination of the influence of changing contents of iron and water on the results of the calcium content determinations, and a device for continuous radiometric determination of calcium and iron in raw slurry was designed and constructed. The device was installed in the cement plant 'Przyjazn' under technical measuring conditions and its applicability was tested. (orig./LH) [de

  10. Advanced radiometric and interferometric milimeter-wave scene simulations

    Science.gov (United States)

    Hauss, B. I.; Moffa, P. J.; Steele, W. G.; Agravante, H.; Davidheiser, R.; Samec, T.; Young, S. K.

    1993-01-01

    Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

  11. Digital image integration technique of multi-geoscience information dominated by aerial radiometric measurements

    International Nuclear Information System (INIS)

    Liu Dechang; Sun Maorong; Zhu Deling; Zhang Jingbo; He Jianguo; Dong Xiuzhen

    1992-02-01

    The geologic metallogenetic environment of uranium at Lian Shan Guan region has been studied by using digital image integration technique of multi-geoscience information with aerial radiometric measurements. It includes the classification of uranium-bearing rock, recognizing patterns of ore-forming and geologic mapping in ore field. Some new tectonic structure was found in this region that gives significant information for further exploring of uranium ore. After multi-parameters screening of aerial radiometric data, patterns recognizing and multi-geoscience information integration analysis, four prospective metallogenetic zones were predicted, and the predication was proved by further geologic survey. Three of the four zones are very encouraging, where ore-forming structures, hydrothermal deposits, wall-rock alteration, primary and secondary uranium ore and rich uranium mineralization are discovered. The department of geologic exploring has decided that these zones will enjoy priority in the examination for further prospecting of uranium ores

  12. Pyrotechnic countermeasures: IV. Radiometric performance of a sulphur-based Flare composition

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Ernst-Christian [NATO Munitions Safety Information Analysis Center (MSIAC), Brussels (Belgium)

    2008-10-15

    Radiometric performance of a sulphur-based flare composition has been investigated. Composition comprising sulphur, potassium perchlorate and antimony sulphide has acceptable band ratio but an order of magnitude weaker spectral efficiency than typical carbon-based compositions. The use of other sulphur compounds with potential for increased performance is discussed. For part III see Ref. [1]. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  13. Results from the radiometric validation of Sentinel-3 optical sensors using natural targets

    Science.gov (United States)

    Fougnie, Bertrand; Desjardins, Camille; Besson, Bruno; Bruniquel, Véronique; Meskini, Naceur; Nieke, Jens; Bouvet, Marc

    2016-09-01

    The recently launched SENTINEL-3 mission measures sea surface topography, sea/land surface temperature, and ocean/land surface colour with high accuracy. The mission provides data continuity with the ENVISAT mission through acquisitions by multiple sensing instruments. Two of them, OLCI (Ocean and Land Colour Imager) and SLSTR (Sea and Land Surface Temperature Radiometer) are optical sensors designed to provide continuity with Envisat's MERIS and AATSR instruments. During the commissioning, in-orbit calibration and validation activities are conducted. Instruments are in-flight calibrated and characterized primarily using on-board devices which include diffusers and black body. Afterward, vicarious calibration methods are used in order to validate the OLCI and SLSTR radiometry for the reflective bands. The calibration can be checked over dedicated natural targets such as Rayleigh scattering, sunglint, desert sites, Antarctica, and tentatively deep convective clouds. Tools have been developed and/or adapted (S3ETRAC, MUSCLE) to extract and process Sentinel-3 data. Based on these matchups, it is possible to provide an accurate checking of many radiometric aspects such as the absolute and interband calibrations, the trending correction, the calibration consistency within the field-of-view, and more generally this will provide an evaluation of the radiometric consistency for various type of targets. Another important aspect will be the checking of cross-calibration between many other instruments such as MERIS and AATSR (bridge between ENVISAT and Sentinel-3), MODIS (bridge to the GSICS radiometric standard), as well as Sentinel-2 (bridge between Sentinel missions). The early results, based on the available OLCI and SLSTR data, will be presented and discussed.

  14. Radiometric method for the rapid detection of Leptospira organisms

    Energy Technology Data Exchange (ETDEWEB)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  15. A new radiometric instrument designed to measure the parameters of bituminous coal on transport belts

    International Nuclear Information System (INIS)

    Kubicek, P.

    1993-01-01

    A new radiometric instrument developed in Czechoslovakia, for the measurement of ash content of bituminous coal, and for the determination of approximate values of moisture and weight is described. (Author)

  16. Monitoring of plutonium contaminated solid waste streams. Chapter II: principles and theory of radiometric assay

    International Nuclear Information System (INIS)

    Birkhoff, G.; Bondar, L.; Notea, A.; Segal, Y.

    1977-01-01

    The interpretation of a count rate distribution obtained from radiometric assay of a given waste items population in terms of source strength distribution is discussed. A model for the evaluation of errors, arising from non uniform source density distribution (Pu) within the item volume and heterogeneity of matrix materials, is presented. Points concerning calibration procedures and representativity of reference materials are dealt with. Qualification procedures for possible monitoring systems are outlined on the basis of comparison with reference systems. The latter are composed of reference monitors based on high resolution gamma spectrometry and passive and active neutron techniques. The importance of information upon the elemental composition and density distribution of matrix materials for the interpretation of radiometric assay of solid wastes is stressed

  17. Radiometric Performance of the TerraSAR-X Mission over More Than Ten Years of Operation

    Directory of Open Access Journals (Sweden)

    Marco Schwerdt

    2018-05-01

    Full Text Available The TerraSAR-X mission, based on two satellites, has produced SAR data products of high quality for a number of scientific and commercial applications for more than ten years. To guarantee the stability and the reliability of these highly accurate SAR data products, both systems were first accurately calibrated during their respective commissioning phases and have been permanently monitored since then. Based on a short description of the methods applied, this paper focuses on the radiometric performance including the gain and phase properties of the transmit/receiver modules, the antenna pattern checked by evaluating scenes acquired over uniformly distributed targets and the radiometric stability derived from permanently deployed point targets. The outcome demonstrates the remarkable performance of both systems since their respective launch.

  18. Assessing Radiometric Stability of the 17-Plus-Year TRMM Microwave Imager 1B11 Version-8 (GPM05 Brightness Temperature Product

    Directory of Open Access Journals (Sweden)

    Ruiyao Chen

    2017-12-01

    Full Text Available The NASA Tropical Rainfall Measuring Mission (TRMM Microwave Imager (TMI has produced a 17-plus-year time-series of calibrated microwave radiances that have remarkable value for investigating the effects of the Earth’s climate change over the tropics. Recently, the Global Precipitation Measurement (GPM Inter-Satellite Radiometric Calibration (XCAL Working Group have performed various calibration and corrections that yielded the legacy TMI 1B11 Version 8 (also called GPM05 brightness temperature product, which will be released in late 2017 by the NASA Precipitation Processing System. Since TMI served as the radiometric transfer standard for the TRMM constellation microwave radiometer sensors, it is important to document its accuracy. In this paper, the various improvements applied to TMI 1B11 V8 are summarized, and the radiometric calibration stability is evaluated by comparisons with a radiative transfer model and by XCAL evaluations with the Global Precipitation Measuring Microwave Imager during their 13-month overlap period. Evaluation methods will be described and results will be presented, which demonstrate that TMI has achieved a radiometric stability level of a few deciKelvin over almost two decades.

  19. Two-Year-Old Children Differentiate Test Questions from Genuine Questions

    Science.gov (United States)

    Grosse, Gerlind; Tomasello, Michael

    2012-01-01

    Children are frequently confronted with so-called "test questions". While genuine questions are requests for missing information, test questions ask for information obviously already known to the questioner. In this study we explored whether two-year-old children respond differentially to one and the same question used as either a genuine question…

  20. Recent understanding of the Svalbard basement in the light of new radiometric age determinations

    International Nuclear Information System (INIS)

    Ohta, Y.

    1992-01-01

    Several tectonothermal events in the pre-Carboniferous basement of Svalbard during Caledonian and Proterozoic times have been dated recently by radiometric age determinations. Three or four stages have been recognized in the Caledonian period; a post-orogentic graben formation during the Devonian, a late Caledonian event in the Middle Silurian, an earely Caledonian event in the Middle Ordovician and possibly an earliest event in the Middle to Late Cambrian. The Grenvillian event, 950-1270 Ma, has been well established by both radiometric ages and unconformities in Nordaustlandet and southwestern Spitsbergen. Sveco-Karelian ages, 1670-1750 Ma, also have been obtained from Ny Friesland, northerneastern Spitsbergen. Two even older ages (zircon U-Pb) upper intercept ages), 2.1 and 3.2 Ga, may suggest the presence of still older crust in Svalbard and adjacent areas. 40 refs., 2 figs

  1. Radiometric characteristics of heavy mineral deposits along the west coast of South Africa

    NARCIS (Netherlands)

    Macdonald, W.G.; Rozendaal, A.; de Meijer, R.J.

    During the last decade, exploration and mining of modern-Tertiary heavy mineral beach and raised beach sands along the west coast of South Africa has developed into a major industry. High resolution radiometric techniques have demonstrated their use as a quantitative indicator of total heavy mineral

  2. Virtual and remote experiments for radiometric and photometric measurements

    International Nuclear Information System (INIS)

    Thoms, L-J; Girwidz, R

    2017-01-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net. (paper)

  3. Virtual and remote experiments for radiometric and photometric measurements

    Science.gov (United States)

    Thoms, L.-J.; Girwidz, R.

    2017-09-01

    The analysis of spectra is fundamental to our modern understanding of wave optics and colour perception. Since spectrometers are expensive, and accurate calibration is necessary to achieve high quality spectra, we developed a remote lab on optical spectrometry. With this tool, students can carry out real experiments over the Internet. In this article the pros and cons of remote labs, the physical background of optical spectrometry, and the development and use of a radiometric remote lab for higher education are discussed. The remote lab is freely accessible to everyone at http://virtualremotelab.net.

  4. On the lower of limit detection of radiometric systems

    International Nuclear Information System (INIS)

    Kamburov, H.; Boneva, S.

    1983-01-01

    The existing definitions of the quantity Asub(min), the lower detection limit, introduced as a characteristic of the sensitivity of radiometric systems are reviewed. A convenient way is found for comparing the different definitions by showing that each definition is connected with a specific value of the probability a of Type I error. The detection limits are calculated for a normal and Poisson distributions of the measured quantities. A criterion is proposed for the applicability of the normal distiribution to the problem of determining the lower detection limit

  5. New argon-argon (40Ar/39Ar) radiometric age dates from selected subsurface basalt flows at the Idaho National Laboratory, Idaho

    Science.gov (United States)

    Hodges, Mary K. V.; Turrin, Brent D.; Champion, Duane E.; Swisher, Carl C.

    2015-01-01

    In 2011, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, collected samples for 12 new argon-argon radiometric ages from eastern Snake River Plain olivine tholeiite basalt flows in the subsurface at the Idaho National Laboratory. The core samples were collected from flows that had previously published paleomagnetic data. Samples were sent to Rutgers University for argon-argon radiometric dating analyses.

  6. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  7. Far-ir heterodyne radiometric measurements with quasioptical Schottky diode mixers

    International Nuclear Information System (INIS)

    Fetterman, H.R.; Tannenwald, P.E.; Clifton, B.J.; Parker, C.D.; Fitzgerald, W.D.; Erickson, N.R.

    1978-01-01

    We have made heterodyne radiometric measurements with GaAs Schottky diode mixers, mounted in a corner-reflector configuration, over the spectral range 170 μm to 1 mm. At 400 μm, system noise temperatures of 9700 K DSB (NEP=1.4 x 10 - 19 W/Hz) and mixer noise temperatures of 5900 K have been achieved. This same quasioptical mixer has also been used to generate 10 - 7 W of tunable radiation suitable for spectroscopic applications

  8. Importance of radiometric survey in radiodiagnosis installationscalculated

    International Nuclear Information System (INIS)

    Leyton, Fernando; Alarcon, Luis; Zapata, Victor H.; Ortega, Dulia; Ramirez, Alfredo; Aravena, Gonzalo; Ubeda, Carlos; Oyarzun, Carlos; Inzulza, Alonso

    2005-01-01

    A radiometric survey was conducted in two services of imaging with a total of 7 evaluated radiology rooms. The Quality Control Protocol methodology was used in Radiology ARCAL (Regional Agreement of cooperation for the promotion of nuclear science and technology in Latin America and the Caribbean) XLIX of the International Atomic Energy Agency (IAEA). The effective dose in different positions of interest rates were calculated, from the point of view of radiation protection. All evaluated rooms have rates of effective doses that meet the values limits set in the Protocol ARCAL XLIX, for 82% of the positions evaluated. However operators located in the position A (controlled area) exceed on average 370% with a range of [1-870] the limit proposed by ARCAL XLIX

  9. Experiences with radiometric solid matter determination in the WOLPRYLA-65 fibre production

    International Nuclear Information System (INIS)

    Butz, M.; Traeber, K.

    1977-01-01

    Proceeding from the technology of WOLPRYLA-65 fibre fabrication the applicability of radiometric density measurements for acrylonitrile determination in a dimethylformamide bath has been studied. The measuring equipment and measuring positions are described and further details, such as calibration procedures, measuring accuracy, benefit of continuous and contactless measurements, maintenance efforts, and radiation protection measures are outlined

  10. Combined testing of castings having rough surface

    International Nuclear Information System (INIS)

    Polyakov, Yu.O.; Zav'yalkin, F.M.; Moskvin, V.N.

    1988-01-01

    Mathematical models of a flaw detector for complex testing of castings, containing radiometric and pneumatic converters, are developed and investigated. The efficiency of compensation of casting thickness fluctuation effect on the results of testing in combined information processing obtained by various methods is estimated

  11. Automatic Radiometric Normalization of Multitemporal Satellite Imagery with the Iteratively Re-weighted MAD Transformation

    DEFF Research Database (Denmark)

    Canty, Morton John; Nielsen, Allan Aasbjerg

    2008-01-01

    A recently proposed method for automatic radiometric normalization of multi- and hyper-spectral imagery based on the invariance property of the Multivariate Alteration Detection (MAD) transformation and orthogonal linear regression is extended by using an iterative re-weighting scheme involving no...

  12. Temporal dynamics of sand dune bidirectional reflectance characteristics for absolute radiometric calibration of optical remote sensing data

    Science.gov (United States)

    Coburn, Craig A.; Logie, Gordon S. J.

    2018-01-01

    Attempts to use pseudoinvariant calibration sites (PICS) for establishing absolute radiometric calibration of Earth observation (EO) satellites requires high-quality information about the nature of the bidirectional reflectance distribution function (BRDF) of the surfaces used for these calibrations. Past studies have shown that the PICS method is useful for evaluating the trend of sensors over time or for the intercalibration of sensors. The PICS method was not considered until recently for deriving absolute radiometric calibration. This paper presents BRDF data collected by a high-performance portable goniometer system to develop a temporal BRDF model for the Algodones Dunes in California. By sampling the BRDF of the sand surface at similar solar zenith angles to those normally encountered by EO satellites, additional information on the changing nature of the surface can improve models used to provide absolute radiometric correction. The results demonstrated that the BRDF of a reasonably simple sand surface was complex with changes in anisotropy taking place in response to changing solar zenith angles. For the majority of observation and illumination angles, the spectral reflectance anisotropy observed varied between 1% and 5% in patterns that repeat around solar noon.

  13. Development of absolute radiometric response functions for HyPlant & G-LiHT using SIRCUS Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to provide absolute radiometric and cross-calibrated spectral characterizations for G-LiHT and HyPlant.  The objectives are: (i) to...

  14. Air Kerma above environmental radiometric calibration facility for field equipment

    International Nuclear Information System (INIS)

    Conti, C.C.; Sachett, I.A.; Bertelli, L.; Lopes, R.T.

    2000-01-01

    The use of gamma ray spectrometers broadened the aims of gamma ray surveys, stead of measuring only the gross radiation, as was done with the GM tubes, it is now possible to be used for uranium exploration, geological mapping as an aid to the exploration of non radioactive ores like gold and tin, radiation background measurements to identify hot spots for radiation hazard evaluation and environmental monitoring of fallout from radiological and nuclear accidents. It became necessary to carefully and precisely calibrate the field equipment to be used to get all the information from such uses. There is an environmental radiometric calibration facility for field equipment, consisting of eight radioactive concrete sources, at the Institute of Radioprotection and Dosimetry - IRD (CNEN/Brazil). These sources are cylindrical with 3 m diameter, 0.5 m thick and weigh about 7.5 tons each. The amount and type of the radioactive material, 238 U and 232 Th and 40 K ores in secular radioactive equilibrium, added to the concrete to simulate rock outcrops, varies in order to obtain different gamma fields, varying in both energy and intensity. These different radiation fields were measured with a HPGe portable detector, specifically calibrated for spectrum stripping, and the air kerma energy distribution was determined for each concrete source and compared with the total air kerma calculated from the nuclide concentration and by others radiometric methods. (author)

  15. Effect of non-ideal characteristics of an adder on the efficiency of data storage during scintillation radiometric testing with the use of pulse radiations

    International Nuclear Information System (INIS)

    Nedavnij, O.I.

    1983-01-01

    Problems of statistical summation of electric signals during scintillation radiometric control using pulse sources-betatrons and X-ray apparatus haVe been considered. Using calculation and experimental ways it is shown that non-ideal nature of adder, conditioned by energy consumption in the process of summation, hampers the information storage to a greater degree than in the case of difference of summed signals amplitudes with similar statistical weights. A new algorithm of television introscope operation, permitting to increase the efficiency of data storage is suggested

  16. Radiometric monitoring outdoor municipality Pocinhos-PB

    International Nuclear Information System (INIS)

    Cardinalli Araujo Costa, Michelle; Araujo dos Santos Junior, Jose; Dos Santos Amaral, Romilton

    2015-01-01

    Studies on human exposure to terrestrial radionuclides are important for human health. Therefore, this investigation presents aimed at making radiometric dosimetry Pocinhos municipality in the state of Paraiba. Monitoring was performed in 50 points in urban and rural areas Pocinhos. The estimated external effective dose rate in outdoor environments was obtained in triplicate using a portable gamma spectrometer, to 1.0 m away from the Earth's surface and time set acquisition in terms of environmental radiation levels. The values of these dose rates outdoor environments ranging from 0.53 to 3.94 mSv.y -1 . the arithmetic mean was 0.79 mSv.y -1 , which exceeds the value 0.07 mSv.y -1 corresponding to the global average in outdoor environments. In the city, found a higher radioactivity in rural areas that were uninhabited at the time of the survey. (Author)

  17. THE FUTURE SPACEBORNE HYPERSPECTRAL IMAGER ENMAP: ITS IN-FLIGHT RADIOMETRIC AND GEOMETRIC CALIBRATION CONCEPT

    Directory of Open Access Journals (Sweden)

    M. Schneider

    2012-07-01

    Full Text Available The German Aerospace Center DLR – namely the Earth Observation Center EOC and the German Space Operations Center GSOC – is responsible for the establishment of the ground segment of the future German hyperspectral satellite mission EnMAP (Environmental Mapping and Analysis Program. The Earth Observation Center has long lasting experiences with air- and spaceborne acquisition, processing, and analysis of hyperspectral image data. In the first part of this paper, an overview of the radiometric in-flight calibration concept including dark value measurements, deep space measurements, internal lamps measurements and sun measurements is presented. Complemented by pre-launch calibration and characterization these analyses will deliver a detailed and quantitative assessment of possible changes of spectral and radiometric characteristics of the hyperspectral instrument, e.g. due to degradation of single elements. A geometric accuracy of 100 m, which will be improved to 30 m with respect to a used reference image, if it exists, will be achieved by ground processing. Therfore, and for the required co-registration accuracy between SWIR and VNIR channels, additional to the radiometric calibration, also a geometric calibration is necessary. In the second part of this paper, the concept of the geometric calibration is presented in detail. The geometric processing of EnMAP scenes will be based on laboratory calibration results. During repeated passes over selected calibration areas images will be acquired. The update of geometric camera model parameters will be done by an adjustment using ground control points, which will be extracted by automatic image matching. In the adjustment, the improvements of the attitude angles (boresight angles, the improvements of the interior orientation (view vector and the improvements of the position data are estimated. In this paper, the improvement of the boresight angles is presented in detail as an example. The other

  18. The Future Spaceborne Hyperspectral Imager Enmap: its In-Flight Radiometric and Geometric Calibration Concept

    Science.gov (United States)

    Schneider, M.; Müller, R.; Krawzcyk, H.; Bachmann, M.; Storch, T.; Mogulsky, V.; Hofer, S.

    2012-07-01

    The German Aerospace Center DLR - namely the Earth Observation Center EOC and the German Space Operations Center GSOC - is responsible for the establishment of the ground segment of the future German hyperspectral satellite mission EnMAP (Environmental Mapping and Analysis Program). The Earth Observation Center has long lasting experiences with air- and spaceborne acquisition, processing, and analysis of hyperspectral image data. In the first part of this paper, an overview of the radiometric in-flight calibration concept including dark value measurements, deep space measurements, internal lamps measurements and sun measurements is presented. Complemented by pre-launch calibration and characterization these analyses will deliver a detailed and quantitative assessment of possible changes of spectral and radiometric characteristics of the hyperspectral instrument, e.g. due to degradation of single elements. A geometric accuracy of 100 m, which will be improved to 30 m with respect to a used reference image, if it exists, will be achieved by ground processing. Therfore, and for the required co-registration accuracy between SWIR and VNIR channels, additional to the radiometric calibration, also a geometric calibration is necessary. In the second part of this paper, the concept of the geometric calibration is presented in detail. The geometric processing of EnMAP scenes will be based on laboratory calibration results. During repeated passes over selected calibration areas images will be acquired. The update of geometric camera model parameters will be done by an adjustment using ground control points, which will be extracted by automatic image matching. In the adjustment, the improvements of the attitude angles (boresight angles), the improvements of the interior orientation (view vector) and the improvements of the position data are estimated. In this paper, the improvement of the boresight angles is presented in detail as an example. The other values and combinations

  19. Radiometric immunosorbent assay for the detection of anti-hormone-binding protein antibodies

    International Nuclear Information System (INIS)

    Pierce, E.A.; Dame, M.C.; DeLuca, H.F.

    1986-01-01

    A radiometric immunosorbent assay (RISA) for the detection of monoclonal antibodies to hormone-binding proteins has been developed. The assay involves incubating hybridoma supernatants in microtiter wells that have been coated with goat anti-mouse IgG antibodies. Any mouse IgG in the test supernatant is thus specifically retained in the wells. Radioactive ligand-binding protein complexes are then incubated in the wells. The presence of anti-binding protein antibodies in the supernatant is indicated by specific retention of radioactive ligand-binding protein complexes in the wells. Crude antigen preparations, such as tissue homogenates, can be used to detect antibodies. The assay is capable of detecting antibody at concentrations 20 ng/ml (approx. 100 pM IgG). The RISA has been used successfully to screen for monoclonal antibodies to the intracellular receptor for 1,25-dihydroxyvitamin D 3 and should be useful for the detection of antibodies to ligand-binding proteins in general

  20. Digital Airborne Photogrammetry—A New Tool for Quantitative Remote Sensing?—A State-of-the-Art Review On Radiometric Aspects of Digital Photogrammetric Images

    Directory of Open Access Journals (Sweden)

    Nikolaj Veje

    2009-09-01

    Full Text Available The transition from film imaging to digital imaging in photogrammetric data capture is opening interesting possibilities for photogrammetric processes. A great advantage of digital sensors is their radiometric potential. This article presents a state-of-the-art review on the radiometric aspects of digital photogrammetric images. The analysis is based on a literature research and a questionnaire submitted to various interest groups related to the photogrammetric process. An important contribution to this paper is a characterization of the photogrammetric image acquisition and image product generation systems. The questionnaire revealed many weaknesses in current processes, but the future prospects of radiometrically quantitative photogrammetry are promising.

  1. Radiometric research in soils cultivated with sugar cane in Pernambuco - Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Santos Junior, Otavio P. dos; Santos Junior, Jose A. dos; Amaral, Romilton dos S.; Menezes, Romulo S.C.; Santos, Josineide M.N. dos; Silva, Arykerne N.C. da; Fernandez, Zahily H.; Rojas, Lino A.V.; Damascena, Kennedy F.R.; Silva, Rafael R.; Milan, Marvic O., E-mail: rodriguesrs19@gmail.com, E-mail: otavio.santos@vitoria.ifpe.edu.br, E-mail: lino.valcarcel@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Vitoria de Santo Antao, PE (Brazil); Centro de Aplicaciones Tecnologicas y Desarrollo Nuclear, La Habana (Cuba); Instituto Superior de Tecnologias y Ciencias Aplicadas Quinta de los Molinos, La Habana (Cuba)

    2017-11-01

    The state of Pernambuco is representative of Northeastern Brazil, with respect to the variability of climatic conditions, soil types, soil cover, as well as land use. The state is subdivided into five regions: Recife Metropolitan Region, Sao Francisco, Sertao, Agreste and Zona da Mata (Atlantic Forest Region). Each region presents peculiar climatic and economic activities. The Atlantic Forest region, the focus of this study, presents a humid tropical climate and is characterized by large farms and the monoculture of sugarcane. In this scenario, a radioecological investigation was carried out to determine the radiometric potential from the analysis of forty-five soil samples, collected in five soil profiles, to a depth of 60 cm. A non-destructive method was adopted for the radiometric analysis, using High- Resolution Gamma Spectrometry with an HPGe-Be type detector. This method allowed the determination of specific activities of U-238, Th-232 and K-40 in the soil samples. The results will be used as a basis for the determination of a reference value for the natural radioactivity of these soils, to predict the existence of possible environmental impacts resulting from their use for the cultivation of sugar cane, as well as to contribute to guarantee the safety of food crops cultivated in this region. (author)

  2. Radiometric research in soils cultivated with sugar cane in Pernambuco - Brazil

    International Nuclear Information System (INIS)

    Santos Junior, Otavio P. dos; Santos Junior, Jose A. dos; Amaral, Romilton dos S.; Menezes, Romulo S.C.; Santos, Josineide M.N. dos; Silva, Arykerne N.C. da; Fernandez, Zahily H.; Rojas, Lino A.V.; Damascena, Kennedy F.R.; Silva, Rafael R.; Milan, Marvic O.

    2017-01-01

    The state of Pernambuco is representative of Northeastern Brazil, with respect to the variability of climatic conditions, soil types, soil cover, as well as land use. The state is subdivided into five regions: Recife Metropolitan Region, Sao Francisco, Sertao, Agreste and Zona da Mata (Atlantic Forest Region). Each region presents peculiar climatic and economic activities. The Atlantic Forest region, the focus of this study, presents a humid tropical climate and is characterized by large farms and the monoculture of sugarcane. In this scenario, a radioecological investigation was carried out to determine the radiometric potential from the analysis of forty-five soil samples, collected in five soil profiles, to a depth of 60 cm. A non-destructive method was adopted for the radiometric analysis, using High- Resolution Gamma Spectrometry with an HPGe-Be type detector. This method allowed the determination of specific activities of U-238, Th-232 and K-40 in the soil samples. The results will be used as a basis for the determination of a reference value for the natural radioactivity of these soils, to predict the existence of possible environmental impacts resulting from their use for the cultivation of sugar cane, as well as to contribute to guarantee the safety of food crops cultivated in this region. (author)

  3. In vitro developmental toxicity test detects inhibition of stem cell differentiation by silica nanoparticles

    International Nuclear Information System (INIS)

    Park, Margriet V.D.Z.; Annema, Wijtske; Salvati, Anna; Lesniak, Anna; Elsaesser, Andreas; Barnes, Clifford; McKerr, George; Howard, C. Vyvyan; Lynch, Iseult; Dawson, Kenneth A.; Piersma, Aldert H.; Jong, Wim H. de

    2009-01-01

    While research into the potential toxic properties of nanomaterials is now increasing, the area of developmental toxicity has remained relatively uninvestigated. The embryonic stem cell test is an in vitro screening assay used to investigate the embryotoxic potential of chemicals by determining their ability to inhibit differentiation of embryonic stem cells into spontaneously contracting cardiomyocytes. Four well characterized silica nanoparticles of various sizes were used to investigate whether nanomaterials are capable of inhibition of differentiation in the embryonic stem cell test. Nanoparticle size distributions and dispersion characteristics were determined before and during incubation in the stem cell culture medium by means of transmission electron microscopy (TEM) and dynamic light scattering. Mouse embryonic stem cells were exposed to silica nanoparticles at concentrations ranging from 1 to 100 μg/ml. The embryonic stem cell test detected a concentration dependent inhibition of differentiation of stem cells into contracting cardiomyocytes by two silica nanoparticles of primary size 10 (TEM 11) and 30 (TEM 34) nm while two other particles of primary size 80 (TEM 34) and 400 (TEM 248) nm had no effect up to the highest concentration tested. Inhibition of differentiation of stem cells occurred below cytotoxic concentrations, indicating a specific effect of the particles on the differentiation of the embryonic stem cells. The impaired differentiation of stem cells by such widely used particles warrants further investigation into the potential of these nanoparticles to migrate into the uterus, placenta and embryo and their possible effects on embryogenesis.

  4. Differential diagnosis of breast tumors on the basis of radiothermometric findings

    Directory of Open Access Journals (Sweden)

    V. I. Vidyukov

    2016-01-01

    Full Text Available The paper presents a method for the differential diagnosis of breast tumors in accordance with radiothermometric findings, which is based on the authors’ developed diagnostic technique (Patent No. 2532372 dated 5 September 2014. The radiometric method was used to examine 119 patients with malignant breast tumors, 53 patients with benign breast tumors, and 60 women without breast involvement. The data were obtained in 3 institutions: the Russian Medical Academy of Postgraduate Education, the N.N. Blokhin Russian Cancer Research Center, and Moscow Oncology Dispensary Five. A microwave radiothermometer was used to measure core and skin temperatures in 9 symmetrical points of each breast. Using the findings as a basis, the authors proposed quantitative criteria that ensured that breast tumors should be differentially diagnosed with high specificity.

  5. In search of epigenetic marks in testes and sperm cells of differentially fed boars.

    Directory of Open Access Journals (Sweden)

    Rémy Bruggmann

    Full Text Available In search of transmittable epigenetic marks we investigated gene expression in testes and sperm cells of differentially fed F0 boars from a three generation pig feeding experiment that showed phenotypic differences in the F2 generation. RNA samples from 8 testes of boars that received either a diet enriched in methylating micronutrients or a control diet were analyzed by microarray analysis. We found moderate differential expression between testes of differentially fed boars with a high FDR of 0.82 indicating that most of the differentially expressed genes were false positives. Nevertheless, we performed a pathway analysis and found disparate pathway maps of development_A2B receptor: action via G-protein alpha s, cell adhesion_Tight junctions and cell adhesion_Endothelial cell contacts by junctional mechanisms which show inconclusive relation to epigenetic inheritance. Four RNA samples from sperm cells of these differentially fed boars were analyzed by RNA-Seq methodology. We found no differential gene expression in sperm cells of the two groups (adjusted P-value>0.05. Nevertheless, we also explored gene expression in sperm by a pathway analysis showing that genes were enriched for the pathway maps of bacterial infections in cystic fibrosis (CF airways, glycolysis and gluconeogenesis p.3 and cell cycle_Initiation of mitosis. Again, these pathway maps are miscellaneous without an obvious relationship to epigenetic inheritance. It is concluded that the methylating micronutrients moderately if at all affects RNA expression in testes of differentially fed boars. Furthermore, gene expression in sperm cells is not significantly affected by extensive supplementation of methylating micronutrients and thus RNA molecules could not be established as the epigenetic mark in this feeding experiment.

  6. Ten years of radiometric monitoring in water samples in Uruguay potables plants

    International Nuclear Information System (INIS)

    Perruni, P.

    2000-01-01

    The work exposes the summary of having been radiometrics obtained during the last 10 years in several water treatment plants of the national territory, with the purpose of determining if in the total dose to the one that this exposed one naturally the population of the country, is important the contribution of polluting radioactives in the drinkable water, in function of the geographical area and the time of the year. The investigation is framed inside the Program of Control Radiometrics of Products of Fission in waters, floors, foods and aerosols of the Uruguay developed by the Radiochemistry Department, of the Nuclear Research Center, Montevideo (UY) The samples of water filter, they process and they analyze according to laboratory protocols, had duplicated by each plant, parallel with radio-active, white bottom measures and standards. The results net average obtained for each factory, gave below the one it limits of detection: 2 BQ/Kg for geometry Marinelli and 0.02 BQ/g for plane geometry, with 99,3% of dependability (standard 3 deviations), very below the maximum values admitted by International Organisms (WHO, FAO, ICRP) [es

  7. Structural and photocarrier radiometric characterization of Cux(CdTe)yOz thin films growth by reactive sputtering

    International Nuclear Information System (INIS)

    Velazquez-Hernandez, R.; Rojas-Rodriguez, I.; Carmona-Rodriguez, J.; Jimenez-Sandoval, S.; Rodriguez-Garcia, M.E.

    2011-01-01

    This research presents a structural and photocarrier radiometric (PCR) characterization of Cu x (CdTe) y O z thin films grown using reactive radiofrequency co-sputtering. Electronic distribution induced by variations in dopant concentration as a function of the position was studied using photocarrier radiometric images. Optical and structural characterization of these thin films was carried out by using micro Raman spectroscopy and X-ray diffraction. Due to its nondestructive and noncontact characteristics, the PCR is an excellent technique that permits one to obtain details of lateral electronic distribution across the sample. It was found that Cu target power influences the electronic distribution and produces different phases such as Cu 2 Te and CdO.

  8. On the radiometric measurement of the density distribution occuring at the horizontal hydraulic transport of solid matter

    International Nuclear Information System (INIS)

    Goedde, E.; Weber, M.

    1977-01-01

    In order to estimate the phenomena of the flow in horizontal hydraulic transport of solid matter, measuring the density structure along the vertical pipe diameter is of vital interest for basic investigations. The measurement technology in mixed flows of solid matter and water is very difficult and therefore only few publications on characteristic flow profiles in horizontal pipes are known. In a research programme advanced by the Deutsche Forschungsgemeinschaft investigations were made on the possibility to measure the density profile by means of plain measuring equipment based upon radiometrics. In this paper a combination of a nuclear radiometric polar and parallel scanning method is shown to be suitable for this kind of measurements. (orig.) [de

  9. Spatial and radiometric characterization of multi-spectrum satellite images through multi-fractal analysis

    Science.gov (United States)

    Alonso, Carmelo; Tarquis, Ana M.; Zúñiga, Ignacio; Benito, Rosa M.

    2017-03-01

    Several studies have shown that vegetation indexes can be used to estimate root zone soil moisture. Earth surface images, obtained by high-resolution satellites, presently give a lot of information on these indexes, based on the data of several wavelengths. Because of the potential capacity for systematic observations at various scales, remote sensing technology extends the possible data archives from the present time to several decades back. Because of this advantage, enormous efforts have been made by researchers and application specialists to delineate vegetation indexes from local scale to global scale by applying remote sensing imagery. In this work, four band images have been considered, which are involved in these vegetation indexes, and were taken by satellites Ikonos-2 and Landsat-7 of the same geographic location, to study the effect of both spatial (pixel size) and radiometric (number of bits coding the image) resolution on these wavelength bands as well as two vegetation indexes: the Normalized Difference Vegetation Index (NDVI) and the Enhanced Vegetation Index (EVI). In order to do so, a multi-fractal analysis of these multi-spectral images was applied in each of these bands and the two indexes derived. The results showed that spatial resolution has a similar scaling effect in the four bands, but radiometric resolution has a larger influence in blue and green bands than in red and near-infrared bands. The NDVI showed a higher sensitivity to the radiometric resolution than EVI. Both were equally affected by the spatial resolution. From both factors, the spatial resolution has a major impact in the multi-fractal spectrum for all the bands and the vegetation indexes. This information should be taken in to account when vegetation indexes based on different satellite sensors are obtained.

  10. Radiometric assessment of the sensitivity to antituberculotics of Mycobacterium avium-intracellulare and Mycobacterium xenopi

    International Nuclear Information System (INIS)

    Kubin, M.; Lindholm-Levy, P.; Heifets, L. B.

    1994-01-01

    The macrodilution radiometric method using Middlebrook's 7H12 liquid medium enriched with 14 C-palmitic acid, where the growth activity is monitored by measuring liberated 14 CO 2 , was applied to 25 strains of the Mycobacterium avium complex and to 20 strains of Mycobacterium xenopi to determine the minimal inhibitory concentrations of the following chemotherapeutical agents: ciprofloxacine, clofazimine, rifampin, cycloserine, kanamycin, etionamide, ethambutol, and amikacin. In the case of the M. avium complex, slightly or completely resistant strains were found for the majority of drugs. The sensitive strain proportion was highest with clofazimine and amikacin. The M. xenopis strains exhibited generally lower minimal inhibitory concentrations than the avian mycobacteria for all drugs except for cycloserine and ethambutol. The radiometric method using the BACTEC system was found suitable for the determination of the sensitivity of mycobacteria to chemotherapeutic agents: the results are obtained rapidly, within 8 days following inoculation, and the minimal inhibitory concentrations can be evaluated quantitatively. 1 tab., 8 refs

  11. The moon as a radiometric reference source for on-orbit sensor stability calibration

    Science.gov (United States)

    Stone, T.C.

    2009-01-01

    The wealth of data generated by the world's Earth-observing satellites, now spanning decades, allows the construction of long-term climate records. A key consideration for detecting climate trends is precise quantification of temporal changes in sensor calibration on-orbit. For radiometer instruments in the solar reflectance wavelength range (near-UV to shortwave-IR), the Moon can be viewed as a solar diffuser with exceptional stability properties. A model for the lunar spectral irradiance that predicts the geometric variations in the Moon's brightness with ???1% precision has been developed at the U.S. Geological Survey in Flagstaff, AZ. Lunar model results corresponding to a series of Moon observations taken by an instrument can be used to stabilize sensor calibration with sub-percent per year precision, as demonstrated by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The inherent stability of the Moon and the operational model to utilize the lunar irradiance quantity provide the Moon as a reference source for monitoring radiometric calibration in orbit. This represents an important capability for detecting terrestrial climate change from space-based radiometric measurements.

  12. Evidence of cracks in austenitic pipe weldings with a radiometric inspection system; Nachweis von Rissen in austenitischen Rohrleitungsnaehten mit einem radiometrischen Pruefsystem

    Energy Technology Data Exchange (ETDEWEB)

    Maier, H.J.; Wuensch, W. [Stuttgart Univ. (Germany). Staatliche Materialpruefungsanstalt

    1999-08-01

    The paper reports the development of a radiometric prototype device and its application to inspection of austenitic weldings with intercrystalline crack defects. The device initially was intended to be used for supplemental inspection for clarification of contradictory or unclear testing results, but the results obtained justify to consider the possibility of using it as an independent, full-scope testing instrument. (orig./CB) [Deutsch] Berichtet wird ueber die Entwicklung eines Prototypes eines Radiometrie-Geraetes zur Pruefung von austenitischen Schweissnaehten mit interkristalliner Rissbildung, zunaechst als Entscheidungshilfe bei unklaren bzw. sich widersprechenden Pruefresultaten. Zwischenzeitlich wird auch daran gedacht, ein solches Geraet fuer eine vollstaendige Pruefung weiter zu entwickeln. (orig./DGE)

  13. OCRA radiometric cloud fractions for GOME-2 on MetOp-A/B

    Science.gov (United States)

    Lutz, Ronny; Loyola, Diego; Gimeno García, Sebastián; Romahn, Fabian

    2016-05-01

    This paper describes an approach for cloud parameter retrieval (radiometric cloud-fraction estimation) using the polarization measurements of the Global Ozone Monitoring Experiment-2 (GOME-2) onboard the MetOp-A/B satellites. The core component of the Optical Cloud Recognition Algorithm (OCRA) is the calculation of monthly cloud-free reflectances for a global grid (resolution of 0.2° in longitude and 0.2° in latitude) to derive radiometric cloud fractions. These cloud fractions will serve as a priori information for the retrieval of cloud-top height (CTH), cloud-top pressure (CTP), cloud-top albedo (CTA) and cloud optical thickness (COT) with the Retrieval Of Cloud Information using Neural Networks (ROCINN) algorithm. This approach is already being implemented operationally for the GOME/ERS-2 and SCIAMACHY/ENVISAT sensors and here we present version 3.0 of the OCRA algorithm applied to the GOME-2 sensors. Based on more than five years of GOME-2A data (April 2008 to June 2013), reflectances are calculated for ≈ 35 000 orbits. For each measurement a degradation correction as well as a viewing-angle-dependent and latitude-dependent correction is applied. In addition, an empirical correction scheme is introduced in order to remove the effect of oceanic sun glint. A comparison of the GOME-2A/B OCRA cloud fractions with colocated AVHRR (Advanced Very High Resolution Radiometer) geometrical cloud fractions shows a general good agreement with a mean difference of -0.15 ± 0.20. From an operational point of view, an advantage of the OCRA algorithm is its very fast computational time and its straightforward transferability to similar sensors like OMI (Ozone Monitoring Instrument), TROPOMI (TROPOspheric Monitoring Instrument) on Sentinel 5 Precursor, as well as Sentinel 4 and Sentinel 5. In conclusion, it is shown that a robust, accurate and fast radiometric cloud-fraction estimation for GOME-2 can be achieved with OCRA using polarization measurement devices (PMDs).

  14. Radiometric calibration of a polarization-sensitive sensor

    International Nuclear Information System (INIS)

    Ahmad, S.P.; Markham, B.L.

    1992-01-01

    The radiometric accuracy of a sensor is adversely affected by scene polarization if its optical system is sensitive to polarization. Tests performed on the reflective bands of the NS001 Thematic Mapper simulator, an aircraft multispectral scanner, show that it is very sensitive to the polarization state of the incoming radiations. For 100 percent linearly polarized light, errors in the measured intensity vary from -40 to +40 percent, depending on the scan angle and spectral band. To estimate polarization-induced errors in the intensity measured at aircraft level, the intensity and polarization of the atmospheric radiances were simulated using a realistic earth-atmosphere radiative transfer model. For the polarization of atmospheric radiances in the solar meridian plane over a vegetated target, intensity errors may range from -10 to + 10 percent. The polarization-induced errors are highest in the shortest NS001 spectral band (0.450-0.525 microns) because of large atmospheric polarizations contributed by Rayleigh particles and small diluting effects caused by the small contributions of weakly polarized radiations coming from aerosols and the surface. Depending on the illumination and view angles, the errors in derived surface reflectance due to the radiance errors can be very large. In particular, for large off-nadir view angles in the forward scattered direction when the sun is low, the relative errors in the derived surface reflectance can be as large as 4 to 5 times the relative error in the radiances. Polarization sensitivity errors cannot be neglected for the shorter wavelengths when the surface reflectance contribution to atmospheric radiances is very small. 40 refs

  15. The development and application of quantitative methods for the determination of in-situ radiometric uranium grade on the Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Symons, G.

    1985-12-01

    A detailed investigation of background radiation levels near the reef zone in the uranium section of the Western Areas Mine was conducted using a collimated radiometric face scanner. This study demonstrated that these radiation levels can be high; 25% or more of the counts measured when sampling a reef face may originate from a background source, especially from uranium ore rubble on the footwall close to the reef face. A method using a 20mm frontal shield was devised to obtain an accurate background correction. Three calibration schemes, the Area method, the Gamlog method, and the Deconvolution method were implemented for the production of accurate in-situ radiometric uranium grades. This involved the construction of a step-response calibration pad at Pelindaba together with the establisment of appropriate software and underground radiometric sampling procedures. Radiometric grades generated by these calibration procedures from 60 channel sections were on average 10% below those procured from conventional chip sampling. A correlation between gold and uranium grades was also evident. Crushed rock samples were collected to investigate the thorium problem and are still undergoing analysis at the time of writing. Refinements in the design of the collimated face scanner are also described

  16. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  17. The radiometric performances of the Planetary Fourier Spectrometer for Mars exploration

    Science.gov (United States)

    Palomba, E.; Colangeli, L.; Formisano, V.; Piccioni, G.; Cafaro, N.; Moroz, V.

    1999-04-01

    The Planetary Fourier Spectrometer (PFS) is a Fourier transform interferometer, operating in the range 1.2-45 μm. The instrument, previously included in the payload of the failed mission Mars ‧96, is proposed for the future space mission Mars Express, under study by ESA. The present paper is aimed at presenting the radiometric performances of PFS. The two channels (LW and SW) forming PFS were analysed and characterised in terms of sensitivity and noise equivalent brightness. To cover the wide spectral range of PFS, different blackbodies were used for calibration. The built-in blackbodies, needed for the in-flight calibrations, were also characterised. The results show that the LW channel is comparable with IRIS Mariner 9 in terms of noise equivalent brightness. The SW channel performances, while satisfactorily, could be improved by lowering the sensor operative temperature. A simple model of the Mars radiance is used in order to calculate the signal-to-noise ratio on the spectra in typical observation conditions. The computed signal-to-noise ratio for the LW channel varies between 430 and 40, while for the SW channel it ranges from 150 to 30. The radiometric analyses confirm that PFS performances are compliant with the design requirements of the instrument. PFS is fully validated for future remote exploration of the atmosphere and the surface of Mars.

  18. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Alireza G. Kashani

    2015-11-01

    Full Text Available In addition to precise 3D coordinates, most light detection and ranging (LIDAR systems also record “intensity”, loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of “normalization”, “correction”, or “calibration” techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  19. A Review of LIDAR Radiometric Processing: From Ad Hoc Intensity Correction to Rigorous Radiometric Calibration.

    Science.gov (United States)

    Kashani, Alireza G; Olsen, Michael J; Parrish, Christopher E; Wilson, Nicholas

    2015-11-06

    In addition to precise 3D coordinates, most light detection and ranging (LIDAR) systems also record "intensity", loosely defined as the strength of the backscattered echo for each measured point. To date, LIDAR intensity data have proven beneficial in a wide range of applications because they are related to surface parameters, such as reflectance. While numerous procedures have been introduced in the scientific literature, and even commercial software, to enhance the utility of intensity data through a variety of "normalization", "correction", or "calibration" techniques, the current situation is complicated by a lack of standardization, as well as confusing, inconsistent use of terminology. In this paper, we first provide an overview of basic principles of LIDAR intensity measurements and applications utilizing intensity information from terrestrial, airborne topographic, and airborne bathymetric LIDAR. Next, we review effective parameters on intensity measurements, basic theory, and current intensity processing methods. We define terminology adopted from the most commonly-used conventions based on a review of current literature. Finally, we identify topics in need of further research. Ultimately, the presented information helps lay the foundation for future standards and specifications for LIDAR radiometric calibration.

  20. Laboratory tests of overpressure differential systems for smoke protection of lobbies

    Science.gov (United States)

    Szałański, Paweł; Misiński, Jacek

    2017-11-01

    Paper presents the methodology of laboratory tests for ventilation overpressure differential systems for smoke protection of lobbies. Research area consists of two spaces representing the lobby and the area under fire equipped with proper ventilation installation. This allows testing of overpressure differential systems for smoke protection of lobbies. Moreover, piece of laboratory tests results for two selected smoke protection systems for lobbies are presented. First one is standard system with constantly opened transfer-damper mounted between lobby and area under fire. Second one - system with so called "electronic transfer" based on two dampers (supplying air to a lobby and to unprotected area alternatively). Opening and closing both dampers is electronically controlled. Changes of pressure difference between lobby and fire affected area during closing and opening doors between those spaces is presented. Conclusions, concerning the possibility of meeting the time period criteria of pressure difference stabilization required by standards, are presented and discussed for both systems.

  1. The absolute calibration of KOMPSAT-3 and 3A high spatial resolution satellites using radiometric tarps and MFRSR measurments

    Science.gov (United States)

    Yeom, J. M.

    2017-12-01

    Recently developed Korea Multi-Purpose Satellite-3A (KOMPSAT-3A), which is a continuation of the KOMPSAT-1, 2 and 3 earth observation satellite (EOS) programs from the Korea Aerospace Research Institute (KARI) was launched on March, 25 2015 on a Dnepr-1 launch vehicle from the Jasny Dombarovsky site in Russia. After launched, KARI performed in-orbit-test (IOT) including radiometric calibration for 6 months from 14 Apr. to 4 Sep. 2015. KOMPSAT-3A is equipped with two distinctive sensors; one is a high resolution multispectral optical sensor, namely the Advances Earth Image Sensor System-A (AEISS-A) and the other is the Scanner Infrared Imaging System (SIIS). In this study, we focused on the radiometric calibration of AEISS-A. The multispectral wavelengths of AEISS-A are covering three visible regions: blue (450 - 520 nm), green (520 - 600 nm), red (630 - 690 nm), one near infrared (760 - 900 nm) with a 2.0 m spatial resolution at nadir, whereas the panchromatic imagery (450 - 900 nm) has a 0.5 m resolution. Those are the same spectral response functions were same with KOMPSAT-3 multispectral and panchromatic bands but the spatial resolutions are improved. The main mission of KOMPSAT-3A is to develop for Geographical Information System (GIS) applications in environmental, agriculture, and oceanographic sciences, as well as natural hazard monitoring.

  2. Investigation of Pre- and Post-Flight Radiometric Calibration Uncertainties from Surface Based Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heath, D.F.; Wei, Z.Y.; Ahman, Z.

    1997-06-01

    A new technique has been developed for inferring column ozone amounts and aerosol optical depths from zenith sky observations. A new radiometric calibration technique for large aperture remote sensing instruments observing the earth through space has been validated which subsequently increased the accuracy of remote sensing measurements of ozone and vertical profiles using measurements of back-scattered ultraviolet solar radiation.

  3. Semi-infinite photocarrier radiometric model for the characterization of semiconductor wafer

    International Nuclear Information System (INIS)

    Liu Xianming; Li Bincheng; Huang Qiuping

    2010-01-01

    The analytical expression is derived to describe the photocarrier radiometric (PCR) signal for a semi-infinite semiconductor wafer excited by a square-wave modulated laser. For comparative study, the PCR signals are calculated by the semi-infinite model and the finite thickness model with several thicknesses. The fitted errors of the electronic transport properties by semi-infinite model are analyzed. From these results it is evident that for thick samples or at high modulation frequency, the semiconductor can be considered as semi-infinite.

  4. A study of elemental migration from poly(ethylene terephthalate) of food packagings to simulated solutions by radiometric method

    International Nuclear Information System (INIS)

    Soares, Eufemia Paez; Saki, Mitiko; Silva, Leonardo G.A.

    2007-01-01

    Brazilian plastic production for food packagings, in recent years, has grown in the same proportion as food consumption. Considering that the plastic manufacturing involves catalytic processes and the use of additives, when the foods are in direct contact with these materials, the components present in plastics may migrate to the food. The Brazilian Health Surveillance Agency (ANVISA) has established boundary-values of migrants as well as procedures to evaluate migration of elements and substances from plastic packaging to food. In this study elemental composition of poly (ethylene terephthalate) - PET - packaging and results of elemental migration were obtained. Instrumental Neutron Activation Analysis (INAA) was used to determine elemental concentrations in PET packagings and the radiometric method was applied for elemental migration determination. This radiometric method consisted of irradiating the PET samples with neutrons, followed by migration exposition and radioactivity measurement in food-simulated solution. Experimental conditions used for migration were 10 days exposure period at 40 deg C. Migration was evaluated for soft drink, juice and water PET packaging. The analytical results indicated that PET packagings contain Co and Sb and those elements are transferred to the simulated solutions. However, these migration results were lower than the maximum tolerance values established by ANVISA. The migration detection limits also indicated high sensitivity of the radiometric method. (author)

  5. Radiometric sampling of bucked copper-nickel ores for determining chemical composition

    International Nuclear Information System (INIS)

    Komlev, V.N.; Eliseev, G.I.

    1978-01-01

    Presented are the results and the technique of experimental-methodical works on radiometric sampling of bucked copper-nickel ores for determining chemical composition with their selection and analysis by the neutron-gamma method and by the gamma-gamma method. The error is estimated according to the chosen conditions of sampling. It is found that the gamma-gamma method being more rapid but less accurate is applied for rapid control of ore current, whereas the neutron-gamma method is applied for quality control of ores extracted

  6. Accelerator physics and radiometric properties of superconducting wavelength shifters

    International Nuclear Information System (INIS)

    Scheer, Michael

    2008-01-01

    Subject of this thesis is the operation of wave-length shifters at electron storage rings and their use in radiometry. The basic aspects of the radiometry, the technical requirements, the influence of wave-length shifters on the storage ring, and results of first measurements are presented for a device installed at BESSY. Most of the calculations are carried out by the program WAVE, which has been developed within this thesis. WAVE allows to calculate the synchrotron radiation spectra of wavelength shifters within an relative uncertainty of 1/100000. The properties of wave-length shifters in terms of accelerator physics as well as a generating function for symplectic tracking calculations can also be calculated by WAVE. The later was implemented in the tracking code BETA to investigate the influence of insertion devices on the dynamic aperture and emittance of the storage ring. These studies led to the concept of alternating low- and high-beta-sections at BESSY-II, which allow to operate superconducting insertion devices without a significant distortion of the magnetic optics. To investigate the experimental aspects of the radiometry at wave-length shifters, a program based on the Monte-Carlo-code GEANT4 has been developed. It allows to simulate the radiometrical measurements and the absorption properties of detectors. With the developed codes first radiometrical measurements by the PTB have been analysed. A comparison of measurements and calculations show a reasonable agreement with deviations of about five percent in the spectral range of 40-60 keV behind a 1-mm-Cu filter. A better agreement was found between 20 keV and 80 keV without Cu filter. In this case the measured data agreed within a systematic uncertainty of two percent with the results of the calculations. (orig.)

  7. Reverse radiometric flow injection analysis (RFIA) of radioactive waste-waters with an ASIA (Ismatec) analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Myint, U; Win, N; San, K; Han, B; Myoe, K M [Yangon Univ. (Myanmar). Dept. of Chemistry; Toelgyessy, J [Slovak Technical Univ., Bratislava (Slovakia). Dept. of Environmental Science

    1994-07-01

    A new application of reverse radiometric flow injection analysis is described. RFIA was used for the analysis of radioactive wastewaters. ASIA (Ismatec) analyzer with NaI(Tl) scintillation detector was used in the study of analysis of [sup 131]I containing waste-aster. (author) 4 refs.; 3 figs.

  8. Rapid lysostaphin test to differentiate Staphylococcus and Micrococcus species.

    Science.gov (United States)

    Geary, C; Stevens, M

    1986-01-01

    A rapid, simple lysostaphin lysis susceptibility test to differentiate the genera Staphylococcus and Micrococcus was evaluated. Of 181 strains from culture collections, 95 of 95 Staphylococcus strains were lysed, and 79 of 79 Micrococcus strains were not lysed. The seven Planococcus strains were resistant. Clinical isolates (890) were tested with lysostaphin and for the ability to produce acid from glycerol in the presence of erythromycin. Overall agreement between the methods was 99.2%. All clinical Micrococcus strains (43) were resistant to lysostaphin, and all clinical Staphylococcus strains (847) were susceptible. Seven of the Staphylococcus strains did not produce acid from glycerol in the presence of erythromycin. This lysostaphin test provides results in 2 h. It is easier to perform than previously described lysostaphin lysis methods. It is also more rapid and accurate than the glycerol-erythromycin test. PMID:3519667

  9. Radiometric control of the position of blind holes axes in graphite blocks of high temperature reactors

    International Nuclear Information System (INIS)

    Boutaine, J.L.; Bujas, R.; Lemonnier, A.; Tortel, J.

    1976-01-01

    The principles of a radiometric method intended for controlling the positions of blind hole axes are given. A comparison is made between radiometry and radiography and the performances obtained using a thulium 170 source are described. The automation capabilities are discussed [fr

  10. Vocabulary test format and differential relations to age.

    Science.gov (United States)

    Bowles, Ryan P; Salthouse, Timothy A

    2008-06-01

    Although vocabulary tests are generally considered interchangeable, regardless of format, different tests can have different relations to age and to other cognitive abilities. In this study, 4 vocabulary test formats were examined: multiple-choice synonyms, multiple-choice antonyms, produce the definition, and picture identification. Results indicated that, although they form a single coherent vocabulary knowledge factor, the formats have different relations to age. In earlier adulthood, picture identification had the strongest growth, and produce the definition had the weakest. In later adulthood, picture identification had the strongest decline, and multiple-choice synonyms had the least. The formats differed in their relation to other cognitive variables, including reasoning, spatial visualization, memory, and speed. After accounting for the differential relations to other cognitive variables, differences in relation to age were eliminated with the exception of differences for the picture identification test. No theory of the aging of vocabulary knowledge fully explains these findings. These results suggest that using a single indicator of vocabulary may yield incomplete and somewhat misleading results about the aging of vocabulary knowledge.

  11. Radiometric ratio characterization for low-to-mid CPV modules operating in variable irradiance conditions

    Science.gov (United States)

    Vorndran, Shelby; Russo, Juan; Zhang, Deming; Gordon, Michael; Kostuk, Raymond

    2012-10-01

    In this work, a concentrating photovoltaic (CPV) design methodology is proposed which aims to maximize system efficiency for a given irradiance condition. In this technique, the acceptance angle of the system is radiometrically matched to the angular spread of the site's average irradiance conditions using a simple geometric ratio. The optical efficiency of CPV systems from flat-plate to high-concentration is plotted at all irradiance conditions. Concentrator systems are measured outdoors in various irradiance conditions to test the methodology. This modeling technique is valuable at the design stage to determine the ideal level of concentration for a CPV module. It requires only two inputs: the acceptance angle profile of the system and the site's average direct and diffuse irradiance fractions. Acceptance angle can be determined by raytracing or testing a fabricated prototype in the lab with a solar simulator. The average irradiance conditions can be found in the Typical Metrological Year (TMY3) database. Additionally, the information gained from this technique can be used to determine tracking tolerance, quantify power loss during an isolated weather event, and do more sophisticated analysis such as I-V curve simulation.

  12. The importance of geoprocessing tools in radiometric monitoring of large areas

    Energy Technology Data Exchange (ETDEWEB)

    Dias, Danila Carrijo da Silva [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil); Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas; Silva, Nivaldo Carlos da; Alberti, Heber Luiz Caponi; Guerrero, Eder Tadeu Zenun, E-mail: ncsilva@cnen.gov.b, E-mail: heber@cnen.gov.b, E-mail: edertzg@cnen.gov.b [Comissao Nacional de Energia Nuclear (LAPOC/CNEN-MG), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas

    2011-07-01

    Throughout history, the natural tendency of men to physically characterize their different surroundings has played an important role on the evolution of societies. Today, that tendency combined to the development of computer technologies, has allowed the accelerated growth of the Geographical Information Systems, which permits the analysis and manipulation of spatial data from diverse sources, producing geo referenced databases. The gamma radiation, one of the main contributors of human exposure to natural radiation, is known for its high penetration energy. Today, the environmental gamma radiation is measured through radiometric tracking mobile units, allowing large scale samplings and precise assessments. As a geo processing case study, a radiometric monitoring work was conducted in the town of Aguas da Prata-SP using a tracking mobile system, composed by a scintillator detector, a GPS and a computer, all installed in a vehicle. The data made of collected points and their respective doses and geographical references were captured and stored in a computer software and then inserted and treated in a GIS environment. After a cartographic base was created using a digitalized map of Aguas da Prata, the sampled points were plotted and interpolated with the cartographic base, producing two maps that demonstrate the tracking route and the gamma radiation dose range throughout the monitored area. Geo processing tools have shown great efficiency in this study, allowing agile manipulation and management of a large quantity of data, thus promoting a spatial analysis of natural radiation levels in the studied region. (author)

  13. The importance of geoprocessing tools in radiometric monitoring of large areas

    International Nuclear Information System (INIS)

    Dias, Danila Carrijo da Silva; Comissao Nacional de Energia Nuclear; Silva, Nivaldo Carlos da; Alberti, Heber Luiz Caponi; Guerrero, Eder Tadeu Zenun

    2011-01-01

    Throughout history, the natural tendency of men to physically characterize their different surroundings has played an important role on the evolution of societies. Today, that tendency combined to the development of computer technologies, has allowed the accelerated growth of the Geographical Information Systems, which permits the analysis and manipulation of spatial data from diverse sources, producing geo referenced databases. The gamma radiation, one of the main contributors of human exposure to natural radiation, is known for its high penetration energy. Today, the environmental gamma radiation is measured through radiometric tracking mobile units, allowing large scale samplings and precise assessments. As a geo processing case study, a radiometric monitoring work was conducted in the town of Aguas da Prata-SP using a tracking mobile system, composed by a scintillator detector, a GPS and a computer, all installed in a vehicle. The data made of collected points and their respective doses and geographical references were captured and stored in a computer software and then inserted and treated in a GIS environment. After a cartographic base was created using a digitalized map of Aguas da Prata, the sampled points were plotted and interpolated with the cartographic base, producing two maps that demonstrate the tracking route and the gamma radiation dose range throughout the monitored area. Geo processing tools have shown great efficiency in this study, allowing agile manipulation and management of a large quantity of data, thus promoting a spatial analysis of natural radiation levels in the studied region. (author)

  14. Report on the feasibility of the in situ radiometric determination of uranium grade in Witwatersrand gold and uranium mines

    International Nuclear Information System (INIS)

    Smit, C.J.B.; Wesolinski, E.S.; Corner, B.

    1982-08-01

    The chip-sampling technique currently employed by the South African gold and uranium-mining industry, for the prediction of face grade, has several drawbacks, namely: 1) it is labour-intensive; 2) sample volumes are often unrepresentative and prone to human error; and 3) the uranium mineralisation may be very erratic along the reef. In situ radiometric assaying for uranium along the reef, on the other hand, is a rapid, essentially one-man operation, enabling a much larger and hence a more representative sample volume to be measured. The high radiometric background inherent in any uranium mine necessitates some form of high-density shielding in order to facilitate quantitative in situ assaying. This report, therefore, briefly outlines the origin, nature, detection and shielding of gamma rays. Results obtained with a frontally shielded total-count instrument showed that radiometric estimates of uranium grade are comparable to those obtained by batch mining and can be used for the prediction of face grades, provided that the ore is in radiometric equilibrium and that thorium and potassium are either not present, or vary sympathetically with the uranium grade. Spectral analysis showed, however, that these circumstances will also permit the use of a collimated (side-shielded) detector of acceptable weight, provided that only the low-energy portion of the spectrum is measured. The advantages of a collimated detector over a frontally shielded detector are also noteworthy, viz.: 1) only one reading is taken per sample point rather than two, as is the case with the frontally shielded system, thus improving counting statistics; and 2) the shielding is permanently fixed to the detector. Comprehensive design considerations for a compact, portable instrument are suggested and methods for determining background radiation as applicable to a collimated detector are described

  15. Uncertainty Evaluations of the CRCS In-orbit Field Radiometric Calibration Methods for Thermal Infrared Channels of FENGYUN Meteorological Satellites

    Science.gov (United States)

    Zhang, Y.; Rong, Z.; Min, M.; Hao, X.; Yang, H.

    2017-12-01

    Meteorological satellites have become an irreplaceable weather and ocean-observing tool in China. These satellites are used to monitor natural disasters and improve the efficiency of many sectors of Chinese national economy. It is impossible to ignore the space-derived data in the fields of meteorology, hydrology, and agriculture, as well as disaster monitoring in China, a large agricultural country. For this reason, China is making a sustained effort to build and enhance its meteorological observing system and application system. The first Chinese polar-orbiting weather satellite was launched in 1988. Since then China has launched 14 meteorological satellites, 7 of which are sun synchronous and 7 of which are geostationary satellites; China will continue its two types of meteorological satellite programs. In order to achieve the in-orbit absolute radiometric calibration of the operational meteorological satellites' thermal infrared channels, China radiometric calibration sites (CRCS) established a set of in-orbit field absolute radiometric calibration methods (FCM) for thermal infrared channels (TIR) and the uncertainty of this method was evaluated and analyzed based on TERRA/AQUA MODIS observations. Comparisons between the MODIS at pupil brightness temperatures (BTs) and the simulated BTs at the top of atmosphere using radiative transfer model (RTM) based on field measurements showed that the accuracy of the current in-orbit field absolute radiometric calibration methods was better than 1.00K (@300K, K=1) in thermal infrared channels. Therefore, the current CRCS field calibration method for TIR channels applied to Chinese metrological satellites was with favorable calibration accuracy: for 10.5-11.5µm channel was better than 0.75K (@300K, K=1) and for 11.5-12.5µm channel was better than 0.85K (@300K, K=1).

  16. Titan Density Reconstruction Using Radiometric and Cassini Attitude Control Flight Data

    Science.gov (United States)

    Andrade, Luis G., Jr.; Burk, Thomas A.

    2015-01-01

    This paper compares three different methods of Titan atmospheric density reconstruction for the Titan 87 Cassini flyby. T87 was a unique flyby that provided independent Doppler radiometric measurements on the ground throughout the flyby including at Titan closest approach. At the same time, the onboard accelerometer provided an independent estimate of atmospheric drag force and density during the flyby. These results are compared with the normal method of reconstructing atmospheric density using thruster on-time and angular momentum accumulation. Differences between the estimates are analyzed and a possible explanation for the differences is evaluated.

  17. Anomalies jointing in the Laguna Blanca area (Rocha district) about of radiometric anomaly sector with thorium characteristic

    International Nuclear Information System (INIS)

    Lara, P.

    1986-01-01

    In the following lines are sumarized the prospection works carried out on anomalous radiometric sectors located at the Department of Rocha (Uruguay) Its toriferous feature and the likely metallogenetic model to which they are associated are also developed

  18. Examining sex differentials in the uptake and process of HIV testing in three high prevalence districts of India.

    Science.gov (United States)

    Joseph, Saju; Kielmann, Karina; Kudale, Abhay; Sheikh, Kabir; Shinde, Swati; Porter, John; Rangan, Sheela

    2010-03-01

    Sex differentials in the uptake of HIV testing have been reported in a range of settings, however, men's and women's testing patterns are not consistent across these settings, suggesting the need to set sex differentials against gender norms in patient testing behaviour and provider practices. A community-based, cross-sectional survey among 347 people living with HIV in three HIV high prevalence districts of India examined reasons for undergoing an HIV test, location of testing and conditions under which individuals were tested. HIV testing was almost always provider-initiated for men. Men were more likely to be advised to test by a private practitioner and to test in the private sector. Women were more likely to be advised to test by a family member, and to test in the public sector. Men were more likely to receive pre-test information than women, when tested in the private sector. Men were also more likely to receive direct disclosure of their HIV positive status by a health provider, regardless of the sector in which they tested. More women than men were repeatedly tested for HIV, regardless of sector. These sex differentials in the uptake and process of HIV testing are partially explained through differences in public and private sector testing practices. However, they also reflect women's lack of awareness and agency in HIV care seeking and differential treatment by providers. Examining gender dynamics that underpin sex differentials in HIV testing patterns and practices is essential for a realistic assessment of the challenges and implications of scaling-up HIV testing and mainstreaming gender in HIV/AIDS programmes.

  19. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II

    International Nuclear Information System (INIS)

    Harangozo, M.; Jombik, J.; Schiller, P.; Toelgyessy, J.

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l -1 NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed. (author)

  20. Stationary point of the radiometric control of cesium contamination of agricultural animals

    International Nuclear Information System (INIS)

    1997-01-01

    Stationary point of the radiometric control of cesium contamination of an agricultural animals. Is intended for vital measurements of the contents of radiocesium in muscular tissue of a cattle. Can be used on cattle-breeding farms, providing points, in meat factories and personal facilities. As a base means for accommodation of the control point the motor-car is used. Design of the car allows to automate operations on deployment of the control point on a place and translation of one to a transport mode. Limits of measured specific activity of cesium contamination of a cattle is up 5*10 -9 to 5*10 -6 Ci/kg. The basic error on the bottom limit of measurement at confidence coefficient 0,95 is no more than 30%. Measurement time for the bottom limit of determined specific activity is no more than 30 s. There is automatic measurement mode. Type of a power is 220 V, 50 Hz. Range of working temperatures is up -15 to +35 centigrade. Relative humidity is no more than 98% at 25 centigrade. External gamma background is till 0.035 mR/h. Time of installation and dismantle of stationary control point is no more than 1,5 hours. The direct radiometric control in divo allows to fulfil and to use biotechnological process of removing of cesium isotopes from body of animals for decrease of levels of radioactive contamination

  1. Differential Item Functioning in While-Listening Performance Tests: The Case of the International English Language Testing System (IELTS) Listening Module

    Science.gov (United States)

    Aryadoust, Vahid

    2012-01-01

    This article investigates a version of the International English Language Testing System (IELTS) listening test for evidence of differential item functioning (DIF) based on gender, nationality, age, and degree of previous exposure to the test. Overall, the listening construct was found to be underrepresented, which is probably an important cause…

  2. Notes on the radiometric and geochemical survey of Leyte Island

    International Nuclear Information System (INIS)

    Santos, G. Jr.

    1982-01-01

    Radioactivity measurements using the Scintrex GIS-4 portable scintillometer were conducted along the periphery of the island. These radiometric readings as well as sediments were obtained along the streams draining into the sea. A total of 174 stream sediments samples were collected. Minus 80 mesh sediment fraction was analyzed for mobile or extractable uranium. Results indicated that the background values of radioactivity and uranium in stream sediments were 25 counts per second (cps) and 0.3 ppm, respectively. The San Isidro and Vilaba areas which are located in the northern part of Leyte have greater than 3 times above background radioactivity and uranium in the stream sediments. (author)

  3. SENSOR CORRECTION AND RADIOMETRIC CALIBRATION OF A 6-BAND MULTISPECTRAL IMAGING SENSOR FOR UAV REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    J. Kelcey

    2012-07-01

    Full Text Available The increased availability of unmanned aerial vehicles (UAVs has resulted in their frequent adoption for a growing range of remote sensing tasks which include precision agriculture, vegetation surveying and fine-scale topographic mapping. The development and utilisation of UAV platforms requires broad technical skills covering the three major facets of remote sensing: data acquisition, data post-processing, and image analysis. In this study, UAV image data acquired by a miniature 6-band multispectral imaging sensor was corrected and calibrated using practical image-based data post-processing techniques. Data correction techniques included dark offset subtraction to reduce sensor noise, flat-field derived per-pixel look-up-tables to correct vignetting, and implementation of the Brown- Conrady model to correct lens distortion. Radiometric calibration was conducted with an image-based empirical line model using pseudo-invariant features (PIFs. Sensor corrections and radiometric calibration improve the quality of the data, aiding quantitative analysis and generating consistency with other calibrated datasets.

  4. A simple and effective radiometric correction method to improve landscape change detection across sensors and across time

    Science.gov (United States)

    Chen, X.; Vierling, Lee; Deering, D.

    2005-01-01

    Satellite data offer unrivaled utility in monitoring and quantifying large scale land cover change over time. Radiometric consistency among collocated multi-temporal imagery is difficult to maintain, however, due to variations in sensor characteristics, atmospheric conditions, solar angle, and sensor view angle that can obscure surface change detection. To detect accurate landscape change using multi-temporal images, we developed a variation of the pseudoinvariant feature (PIF) normalization scheme: the temporally invariant cluster (TIC) method. Image data were acquired on June 9, 1990 (Landsat 4), June 20, 2000 (Landsat 7), and August 26, 2001 (Landsat 7) to analyze boreal forests near the Siberian city of Krasnoyarsk using the normalized difference vegetation index (NDVI), enhanced vegetation index (EVI), and reduced simple ratio (RSR). The temporally invariant cluster (TIC) centers were identified via a point density map of collocated pixel VIs from the base image and the target image, and a normalization regression line was created to intersect all TIC centers. Target image VI values were then recalculated using the regression function so that these two images could be compared using the resulting common radiometric scale. We found that EVI was very indicative of vegetation structure because of its sensitivity to shadowing effects and could thus be used to separate conifer forests from deciduous forests and grass/crop lands. Conversely, because NDVI reduced the radiometric influence of shadow, it did not allow for distinctions among these vegetation types. After normalization, correlations of NDVI and EVI with forest leaf area index (LAI) field measurements combined for 2000 and 2001 were significantly improved; the r 2 values in these regressions rose from 0.49 to 0.69 and from 0.46 to 0.61, respectively. An EVI "cancellation effect" where EVI was positively related to understory greenness but negatively related to forest canopy coverage was evident across a

  5. PTB’s radiometric scales for UV and VUV source calibration based on synchrotron radiation

    Science.gov (United States)

    Klein, Roman; Kroth, Simone; Paustian, Wolfgang; Richter, Mathias; Thornagel, Reiner

    2018-06-01

    The radiant intensity of synchrotron radiation can be accurately calculated with classical electrodynamics. This primary realization of the spectral radiant intensity has been used by PTB at several electron storage rings which have been optimized to be operated as primary source standards for the calibration of transfer sources in the spectral range of UV and VUV for almost 30 years. The transfer sources are compared to the primary source standard by means of suitable wavelength-dispersive transfer stations. The spectral range covered by deuterium lamps, which represent transfer sources that are easy to handle, is of particular relevance in practice. Here, we report on developments in the realization and preservation of the radiometric scales for spectral radiant intensity and spectral radiance in the wavelength region from 116 nm to 400 nm, based on a set of deuterium reference lamps, over the last few decades. An inside view and recommendations on the operation of the D2 lamps used for the realization of the radiometric scale are presented. The data has been recently compiled to illustrate the chronological behaviour at various wavelengths. Moreover, an overview of the internal and external validation measurements and intercomparisons is given.

  6. Standard Test Method for Calibration of Non-Concentrator Photovoltaic Secondary Reference Cells

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers calibration and characterization of secondary terrestrial photovoltaic reference cells to a desired reference spectral irradiance distribution. The recommended physical requirements for these reference cells are described in Specification E1040. Reference cells are principally used in the determination of the electrical performance of a photovoltaic device. 1.2 Secondary reference cells are calibrated indoors using simulated sunlight or outdoors in natural sunlight by reference to a primary reference cell previously calibrated to the same desired reference spectral irradiance distribution. 1.3 Secondary reference cells calibrated according to this test method will have the same radiometric traceability as the of the primary reference cell used for the calibration. Therefore, if the primary reference cell is traceable to the World Radiometric Reference (WRR, see Test Method E816), the resulting secondary reference cell will also be traceable to the WRR. 1.4 This test method appli...

  7. Design, manufacture, and calibration of infrared radiometric blackbody sources

    International Nuclear Information System (INIS)

    Byrd, D.A.; Michaud, F.D.; Bender, S.C.

    1996-04-01

    A Radiometric Calibration Station (RCS) is being assembled at the Los Alamos National Laboratories (LANL) which will allow for calibration of sensors with detector arrays having spectral capability from about 0.4-15 μm. The configuration of the LANL RCS. Two blackbody sources have been designed to cover the spectral range from about 3-15 μm, operating at temperatures ranging from about 180-350 K within a vacuum environment. The sources are designed to present a uniform spectral radiance over a large area to the sensor unit under test. The thermal uniformity requirement of the blackbody cavities has been one of the key factors of the design, requiring less than 50 mK variation over the entire blackbody surface to attain effective emissivity values of about 0.999. Once the two units are built and verified to the level of about 100 mK at LANL, they will be sent to the National Institute of Standards and Technology (NIST), where at least a factor of two improvement will be calibrated into the blackbody control system. The physical size of these assemblies will require modifications of the existing NIST Low Background Infrared (LBIR) Facility. LANL has constructed a bolt-on addition to the LBIR facility that will allow calibration of our large aperture sources. Methodology for attaining the two blackbody sources at calibrated levels of performance equivalent to present state of the art will be explained in the following

  8. Diurnal remote sensing of coastal/oceanic waters: a radiometric analysis for Geostationary Coastal and Air Pollution Events.

    Science.gov (United States)

    Pahlevan, Nima; Lee, Zhongping; Hu, Chuanmin; Schott, John R

    2014-02-01

    Optical remote sensing systems aboard geostationary platforms can provide high-frequency observations of bio-optical properties in dynamical coastal/oceanic waters. From the end-user standpoint, it is recognized that the fidelity of daily science products relies heavily on the radiometric sensitivity/performance of the imaging system. This study aims to determine the theoretical detection limits for bio-optical properties observed diurnally from a geostationary orbit. The analysis is based upon coupled radiative transfer simulations and the minimum radiometric requirements defined for the GEOstationary Coastal and Air Pollution Events (GEO-CAPE) mission. The diurnal detection limits are found for the optically active constituents of water, including near-surface concentrations of chlorophyll-a (CHL) and total suspended solids (TSS), and the absorption of colored dissolved organic matter (aCDOM). The diurnal top-of-atmosphere radiance (Lt) is modeled for several locations across the field of regard (FOR) to investigate the radiometric sensitivity at different imaging geometries. It is found that, in oceanic waters (CHL=0.07  mg/m3), detecting changes smaller than 0.01  mg/m3 in CHL is feasible for all locations and hours except for late afternoon observations on the edge of the FOR. For more trophic/turbid waters (0.6radiometric sensitivity of the GEO-CAPE mission in identifying the changes in bio-optical properties at top-of-atmosphere (TOA), which aids in a more lucid

  9. Ground Radiometric Method as a Tool for Determining the Surface Boundary of a Buried Bauxitic Karst

    Directory of Open Access Journals (Sweden)

    Kamal Kareem Ali

    2011-12-01

    Full Text Available Forty two ground radiometric measurements along nine traverses within a rectangular network area were taken across a bauxitic karst within the Ubaid Formation (Lower Jurassic in the Western Desert of Iraq. A 4-Channel Gamma Ray Spectrometer (GAD-6 with sodium iodide NaI (Tl crystal (GSP-4S was used in the field to measure the total radioactivity of the surface soil. Soil samples collected from the surface at each measurement point and core samples collected from a test well penetrating the karst were analyzed by Gamma ray spectrometer. The main objective of this study was to detect the hidden bauxitic karst and determine its surface boundary. The radioactivity on the surface of the karst was ranging between 60 and 80 count per second (c/s, while the background radioactivity of the Ubaid Formation, which hosts the karst, was ranging between 100 and150 c/s. Chemical weathering, especially dissolution and leaching moved uranium (238U and thorium(232Th from the overburden downward. Accordingly, these elements have been adsorbed on the surface of clay minerals and bauxite buried at a depth of about 5m causing enrichment with radioactivity. The leached overburden lack radioelements, so its radioactivity was less than background radioactivity level. The gamma ray spectroanalysis showed that the radioactivity of 238U and 232Th in the overburden was 0.5 and 3 Bq/Kg, whereas, in the bauxite and flint clay bed, it was 240 and 160 Bq/Kg respectively. Based on the radioactivity anomaly contrast on the surface, an isorad map was plotted and the karst diameter which represents low anomaly was determined to be ranging from 150 to 200m. The current study demonstrates that the ground radiometric method is quite useful for detecting the bauxitic karst and inferring its surface boundaries.

  10. Geological, radiometrical, and geochemical studies of Banggai granites and Bobong formation to determine potential Uranium area in Taliabu Island, North Maluku

    International Nuclear Information System (INIS)

    Ngadenin

    2016-01-01

    Geological, radiometrical, and geochemical studies of Banggai granites and Bobong Formation have been conducted in order to obtain potential uranium area. Taliabu Island is selected for the study because Taliabu Island is a micro continent fraction of the Gondwana super continent that separated at the end of the Mesozoic to Paleogene period. Some types of uranium mineralization formed in the period of Gondwana include sandstone-type, lignite coal type, and vein-type. Taliabu Island is a small part from the Gondwana super continent so it is expected will be found uranium mineralization or at least indications of uranium mineralization occurrences. The aim of this study is to obtain uranium potential areas for the development of uranium exploration in the future. The methods used are reviewing geological, radiometric, and geochemical data from various sources. The results of review showed that geological setting, radiometric, and geochemical data gives positive indication to the formation of uranium mineralization for sandstone type. Banggai granite is a potential uranium source. Sandstone of Bobong Formation as a potential host rock. Coal and pyrite as a potential precipitant. Uranium potential area is located on Bobong Formation and its surrounding. (author)

  11. Global Positioning Radiometric Scanner System. Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The US DOE continually seeks safer and more cost-effective technologies for use in decontamination and decommissioning (D and D) of nuclear facilities. To this end, the Deactivation and Decommissioning Focus Area (DDFA) of the DOE OST sponsors the Large Scale Demonstration and Deployment Projects (LSDDP). At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE projects and to others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased costs of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) LSDDP generated a list of statements defining specific needs or problems where improved technology could be incorporated into ongoing D and D tasks. One of the stated needs was for developing technologies that would reduce costs and shorten DDOE/EM--0552DOE/EM--0552 and D schedules by providing radiological characterizations to meet the free-release criteria. The Global Positioning Radiometric Scanner (GPRS system shown in Figure 1) utilizes a detection system; a portable computer, a differential global positioning system (d-gps), and a four wheel drive vehicle. Once the survey data has been collected, a software program called GeoSofttrademark generates a graphical representation of the radiological contamination extent. Baseline technology involves gridding the area and hand surveying each grid. This demonstration investigated the associated costs and the required time to evaluate the radiological characterization data from the GPRS with respect to the baseline technology. The GPRS system performs in-situ, real-time analyses to identify the extent of radiological contamination. Benefits expected from using the new innovative technology (GPRS) include: Reduced labor hours associated with performing the survey; Increased number of survey data points; Reduced

  12. Radiometric and spectral calibrations of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) using principle component analysis

    Science.gov (United States)

    Tian, Jialin; Smith, William L.; Gazarik, Michael J.

    2008-10-01

    The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere's thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw GIFTS interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. The radiometric calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. The absolute radiometric performance of the instrument is affected by several factors including the FPA off-axis effect, detector/readout electronics induced nonlinearity distortions, and fore-optics offsets. The GIFTS-EDU, being the very first imaging spectrometer to use ultra-high speed electronics to readout its large area format focal plane array detectors, operating at wavelengths as large as 15 microns, possessed non-linearity's not easily removable in the initial calibration process. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts remaining after the initial radiometric calibration process, thus, further enhance the absolute calibration accuracy. This method is

  13. Analysis of radiometric signal in sedimentating suspension flow in open channel

    Directory of Open Access Journals (Sweden)

    Zych Marcin

    2015-01-01

    Full Text Available The article discusses issues related to the estimation of the sedimentating solid particles average flow velocity in an open channel using radiometric methods. Due to the composition of the compound, which formed water and diatomite, received data have a very weak signal to noise ratio. In the process analysis the known determining of the solid phase transportation time delay the classical cross-correlation function is the most reliable method. The use of advanced frequency analysis based on mutual spectral density function and wavelet transform of recorded signals allows a reduction of the noise contribution.

  14. Method for radiometric calibration of an endoscope's camera and light source

    Science.gov (United States)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  15. Children's differential susceptibility to parenting: An experimental test of "for better and for worse".

    Science.gov (United States)

    Slagt, Meike; Dubas, Judith Semon; van Aken, Marcel A G; Ellis, Bruce J; Deković, Maja

    2017-02-01

    Differential susceptibility theory proposes that a subset of individuals exist who display enhanced susceptibility to both negative (risk-promoting) and positive (development-enhancing) environments. This experiment represents the first attempt to directly test this assumption by exposing children in the experimental group to both negative and positive feedback using puppet role-plays. It thereby serves as an empirical test as well as a methodological primer for testing differential susceptibility. Dutch children (N=190, 45.3% girls) between the ages of 4 and 6years participated. We examined whether negative and positive feedback would differentially affect changes in positive and negative affect, in prosocial and antisocial intentions and behavior, depending on children's negative emotionality. Results show that on hearing negative feedback, children in the experimental group increased in negative affect and decreased in positive affect more strongly than children in the control group. On hearing positive feedback, children in the experimental group tended to increase in positive affect and decrease in prosocial behavior. However, changes in response to negative or positive feedback did not depend on children's negative emotionality. Moreover, using reliable change scores, we found support for a subset of "vulnerable" children but not for a subset of "susceptible" children. The findings offer suggestions to guide future differential susceptibility experiments. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. PCA determination of the radiometric noise of high spectral resolution infrared observations from spectral residuals: Application to IASI

    Science.gov (United States)

    Serio, C.; Masiello, G.; Camy-Peyret, C.; Jacquette, E.; Vandermarcq, O.; Bermudo, F.; Coppens, D.; Tobin, D.

    2018-02-01

    The problem of characterizing and estimating the instrumental or radiometric noise of satellite high spectral resolution infrared spectrometers directly from Earth observations is addressed in this paper. An approach has been developed, which relies on the Principal Component Analysis (PCA) with a suitable criterion to select the optimal number of PC scores. Different selection criteria have been set up and analysed, which is based on the estimation theory of Least Squares and/or Maximum Likelihood Principle. The approach is independent of any forward model and/or radiative transfer calculations. The PCA is used to define an orthogonal basis, which, in turn, is used to derive an optimal linear reconstruction of the observations. The residual vector that is the observation vector minus the calculated or reconstructed one is then used to estimate the instrumental noise. It will be shown that the use of the spectral residuals to assess the radiometric instrumental noise leads to efficient estimators, which are largely independent of possible departures of the true noise from that assumed a priori to model the observational covariance matrix. Application to the Infrared Atmospheric Sounder Interferometer (IASI) has been considered. A series of case studies has been set up, which make use of IASI observations. As a major result, the analysis confirms the high stability and radiometric performance of IASI. The approach also proved to be efficient in characterizing noise features due to mechanical micro-vibrations of the beam splitter of the IASI instrument.

  17. Analysis of the radiometric survey during the Argonauta reactor operation

    International Nuclear Information System (INIS)

    Oliveira, Eara de S.L.; Cardozo, Katia K.M.; Silva, Joao Carlos P.; Santos, Joao Regis dos

    2013-01-01

    The Argonaut reactor at the Institute of Nuclear Engineering-IEN/CNEN, operates normally, the powers between 1.7 and 340 W on neutrongraphy procedures, production of radionuclides and experimental reactor physics lessons to postgraduate courses. The doses from neutrons and gamma radiation are measured when the reactor is critical, inside the reactor hall and surrounding regions. A study of the data obtained was performed to evaluate the daily need of this survey in the reactor hall. Taking into account the principle ALARA, which aims to optimize and minimize the dose received by the individual, we propose, in this work, through an analysis of the acquired data in occupational radiometric surveys, a reformulation of the area monitoring routine practiced by the team of radiological protection of the Institute of Nuclear Engineering - IEN/CNEN-RJ, whereas other monitoring routines regarding the radiological protection are also applied in the routine of the reactor. The operations under review occurred with the reactor operating 340 W power at intervals of 60, 120 and 180 minutes, in monitoring points in controlled areas, supervised and free. The results showed significant dose values in the output of the J-Channel 9 when the operation occurs with this open. With 180 minutes of operation, the measured values of dose rate were lower than the values at 60 min and 120 operations min. At the point in the supervised area, offsite to the reactor hall, situated in the direction of the J-Channel 9, the value reduces more than 14% in any operating time in relation to the dose rate measured at the point opposite the canal. There is a 50% reduction in the dose rates for operations with and J-9 closed. The results suggest a new frequency of radiometric survey whose mode of operation is maintained in similar conditions, since combined with other relevant practices of radiation protection

  18. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    Science.gov (United States)

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  19. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    Science.gov (United States)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  20. Differential Weighting of Items to Improve University Admission Test Validity

    Directory of Open Access Journals (Sweden)

    Eduardo Backhoff Escudero

    2001-05-01

    Full Text Available This paper gives an evaluation of different ways to increase university admission test criterion-related validity, by differentially weighting test items. We compared four methods of weighting multiple-choice items of the Basic Skills and Knowledge Examination (EXHCOBA: (1 punishing incorrect responses by a constant factor, (2 weighting incorrect responses, considering the levels of error, (3 weighting correct responses, considering the item’s difficulty, based on the Classic Measurement Theory, and (4 weighting correct responses, considering the item’s difficulty, based on the Item Response Theory. Results show that none of these methods increased the instrument’s predictive validity, although they did improve its concurrent validity. It was concluded that it is appropriate to score the test by simply adding up correct responses.

  1. Regional radiometric map of Syria, using gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Aissa, M.; Al-Hent, R.; Nasser, R.

    2005-01-01

    The regional radiometric gamma-ray spectrometry map of Syria, scaled 1/1000000, for surficial concentration of the total radioactivity (Ur), eU, eTh and %K was completely achieved after normalizing the airborne and carbon data sets to match each other. It worthy notice that, the anomalies found to be closely related to either phosphate and/or glauconite deposits. It is worth mentioning that throughout the survey work many scattered occurrences of secondary uranium mineralization were found as spots in some formations and phosphate rocks. Where this phenomena attributes to chemical and physical disseminating instead of accumulating the radioelements. So, that leads to a weak expectation for usual surface uranium deposits where attributed to the oxidizing condition. Then this expectation remains, as an open question requires answering through planning to subsurface prospecting. (Author)

  2. Retrieval of effective cloud field parameters from radiometric data

    Science.gov (United States)

    Paulescu, Marius; Badescu, Viorel; Brabec, Marek

    2017-06-01

    Clouds play a key role in establishing the Earth's climate. Real cloud fields are very different and very complex in both morphological and microphysical senses. Consequently, the numerical description of the cloud field is a critical task for accurate climate modeling. This study explores the feasibility of retrieving the effective cloud field parameters (namely the cloud aspect ratio and cloud factor) from systematic radiometric measurements at high frequency (measurement is taken every 15 s). Two different procedures are proposed, evaluated, and discussed with respect to both physical and numerical restrictions. None of the procedures is classified as best; therefore, the specific advantages and weaknesses are discussed. It is shown that the relationship between the cloud shade and point cloudiness computed using the estimated cloud field parameters recovers the typical relationship derived from measurements.

  3. MISR L1B3 Radiometric Camera-by-camera Cloud Mask Product subset for the RICO region V004

    Data.gov (United States)

    National Aeronautics and Space Administration — This file contains the Radiometric camera-by-camera Cloud Mask dataset over the RICO region. It is used to determine whether a scene is classified as clear or...

  4. Radiometric survey in the sites of Regional office in Fortaleza, research gallery and camp in Itataia, CE (Brazil)

    International Nuclear Information System (INIS)

    1982-02-01

    The radiometric survey in Regional officer sites in Fortaleza, Brazil, research gallery and camp in Itataia is presented. The measurings to be done, the instrumentation used and results obtained are described as well as the conclusions and recommendations. (C.M.) [pt

  5. Design of Test Wrapper Scan Chain Based on Differential Evolution

    Directory of Open Access Journals (Sweden)

    Aijun Zhu

    2013-08-01

    Full Text Available Integrated Circuit has entered the era of design of the IP-based SoC (System on Chip, which makes the IP core reuse become a key issue. SoC test wrapper design for scan chain is a NP Hard problem, we propose an algorithm based on Differential Evolution (DE to design wrapper scan chain. Through group’s mutation, crossover and selection operations, the design of test wrapper scan chain is achieved. Experimental verification is carried out according to the international standard benchmark ITC’02. The results show that the algorithm can obtain shorter longest wrapper scan chains, compared with other algorithms.

  6. Geochemical and radiometric surveys of Sabkhet Al-Jaboul area by investigating trace elements, radon measurements and gamma spectrometry

    International Nuclear Information System (INIS)

    Jubeli, Y.; Aissa, M.; Al-Hilal, M.

    1999-08-01

    Radiometric and geochemical surveys were carried out over various geological formations in Sabkhet Al-Jaboul and its surrounding environment for evaluating the levels of radioactivity in the area. Therefore, a number of exploration techniques were used in this study such as gamma ray spectrometry, geochemical exploration and soil radon measurements. Although the results of this survey indicate some slight variations of which might be useful to distinguish between various lithological units, most of the obtained data do not reveal any significant radiometric values that could be considered important from the exploration point of view. However, these data were successfully handled to estimate the natural background of radioactivity throughout the geological units of the region. The results also showed the importance of the sedimentary transition contact zone where the continental fresh and salt favourable geochemical environment for uranium precipitation when other fundamental geological requirements for developing such concentrations are available. (author)

  7. Analysis of hyperspectral field radiometric data for monitoring nitrogen concentration in rice crops

    Science.gov (United States)

    Stroppiana, D.; Boschetti, M.; Confalonieri, R.; Bocchi, S.; Brivio, P. A.

    2005-10-01

    Monitoring crop conditions and assessing nutrition requirements is fundamental for implementing sustainable agriculture. Rational nitrogen fertilization is of particular importance in rice crops in order to guarantee high production levels while minimising the impact on the environment. In fact, the typical flooded condition of rice fields can be a significant source of greenhouse gasses. Information on plant nitrogen concentration can be used, coupled with information about the phenological stage, to plan strategies for a rational and spatially differentiated fertilization schedule. A field experiment was carried out in a rice field Northern Italy, in order to evaluate the potential of field radiometric measurements for the prediction of rice nitrogen concentration. The results indicate that rice reflectance is influenced by nitrogen supply at certain wavelengths although N concentration cannot be accurately predicted based on the reflectance measured at a given wavelength. Regression analysis highlighted that the visible region of the spectrum is most sensitive to plant nitrogen concentration when reflectance measures are combined into a spectral index. An automated procedure allowed the analysis of all the possible combinations into a Normalized Difference Index (NDI) of the narrow spectral bands derived by spectral resampling of field measurements. The derived index appeared to be least influenced by plant biomass and Leaf Area Index (LAI) providing a useful approach to detect rice nutritional status. The validation of the regressive model showed that the model is able to predict rice N concentration (R2=0.55 [p<0.01] RRMSE=29.4; modelling efficiency close to the optimum value).

  8. A radiometric method for the determination of NADH in subpicomole amounts

    International Nuclear Information System (INIS)

    Weber, G.; Rosenthal, W.; Oberdisse, E.

    1988-01-01

    A radiometric method has been devised for the determination of small quantities of NADH formed in preceding dehydrogenase reactions. In a coupled enzymatic reaction, phosphoglycerate kinase (PGK) catalyzes the transfer of [/sup 32/P]orthophosphate from [gamma-/sup 32/P]ATP to 3-phosphoglycerate; the intermediate, 1,3-[1-/sup 32/P]diphosphoglycerate, is dephosphorylated by glyceraldehyde-3-phosphate dehydrogenase (GAP-DH). [/sup 32/P]Orthophosphate is released proportionally to NADH and can be measured after adsorption of [gamma-/sup 32/P]ATP to activated charcoal. With this method, 0.2 pmol of NADH are detectable in the presence of a 10/sup 4/-fold excess of NAD over NADH

  9. Geochemical signature of columbite-tantalite and radiometric survey of radioactive pegmatites in the region of Parelhas, Rio Grande do Norte, Brazil

    International Nuclear Information System (INIS)

    Moura, Jorge Costa de

    2013-01-01

    This thesis is the result of geochemical, structural and radiometric investigations on radioactive pegmatites of the Borborema Pegmatitic Province in Northeast Brazil. The studied area, located in the surroundings of the city of Parelhas in the region of the Serra da Borborema, is well known for its thousands of pegmatitic bodies exploited in primitive mines called 'garimpos'. The main goal was to find an efficient, cheap and routine inspection procedure to identify the origin of commercialized radioactive columbite-tantalite (coltan) ore. The Brazilian Nuclear Energy Agency (CNEN) controls uranium commerce and nuclear activity in Brazil. Without an effective method to characterize coltan ores from different localities it is impossible to control the trade. The here presented new method was developed by correlating structural features of these pegmatites with the geochemical behavior of their coltan samples. It was found that the variation of the ratio U/Th versus Nb 2 O 5 /Ta 2 O 5 provides geochemical signatures (analytical fingerprints) for the source location of such ore. A test of the new method with coltan samples of commercial batches from the Brazilian states Amapa and Rondonia also generated distinct geochemical signatures. A radiometric survey (CPS) was carried out in several mines and pegmatites to study the environmental impact of gamma radiation. It included in situ measurements of pegmatite walls, host rocks, soil, and accumulated water and revealed that gamma emitters are hardly solubilized and environmental gamma radiation therefore generally is not enhanced to a dangerous level. (author)

  10. Development of a portable ambient temperature radiometric assaying instrument

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Paulus, T.J.

    1995-01-01

    There is a strong need for portable radiometric instrumentation that can accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need, the authors are developing a hand-held, non-cryogenic, low-power gamma- and X-ray measurement and analysis instrument that can both search and then accurately verify the presence of nuclear materials. The authors report on the use of cadmium zinc telluride detectors, signal processing electronics, and the new field-portable instrument based on the MicroNOMAD Multichannel Analyzer from EG and G ORTEC. They will also describe the isotopic analysis that allows uranium enrichment measurements to be made accurately in the field. The benefits of this work are realized in a wide spectrum of applications that include Arms Control, Nuclear Safeguards, Environmental Management, Emergency Response, and Treaty Verification

  11. Measuring two-phase and two-component mixtures by radiometric technique

    International Nuclear Information System (INIS)

    Mackuliak, D.; Rajniak, I.

    1984-01-01

    The possibility was tried of the application of the radiometric method in measuring steam water content. The experiments were carried out in model conditions where steam was replaced with the two-component mixture of water and air. The beta radiation source was isotope 204 Tl (Esub(max)=0.765 MeV) with an activity of 19.35 MBq. Measurements were carried out within the range of the surface density of the mixture from 0.119 kg.m -2 to 0.130 kg.m -2 . Mixture speed was 5.1 m.s -1 to 7.1 m.s -1 . The observed dependence of relative pulse frequency on the specific water content in the mixture was approximated by a linear regression. (B.S.)

  12. Absolute Radiometric Calibration of the GÖKTÜRK-2 Satellite Sensor Using Tuz GÖLÜ (landnet Site) from Ndvi Perspective

    Science.gov (United States)

    Sakarya, Ufuk; Hakkı Demirhan, İsmail; Seda Deveci, Hüsne; Teke, Mustafa; Demirkesen, Can; Küpçü, Ramazan; Feray Öztoprak, A.; Efendioğlu, Mehmet; Fehmi Şimşek, F.; Berke, Erdinç; Zübeyde Gürbüz, Sevgi

    2016-06-01

    TÜBİTAK UZAY has conducted a research study on the use of space-based satellite resources for several aspects of agriculture. Especially, there are two precision agriculture related projects: HASSAS (Widespread application of sustainable precision agriculture practices in Southeastern Anatolia Project Region (GAP) Project) and AKTAR (Smart Agriculture Feasibility Project). The HASSAS project aims to study development of precision agriculture practice in GAP region. Multi-spectral satellite imagery and aerial hyperspectral data along with ground measurements was collected to analyze data in an information system. AKTAR aims to develop models for irrigation, fertilization and spectral signatures of crops in Inner Anatolia. By the end of the project precision agriculture practices to control irrigation, fertilization, pesticide and estimation of crop yield will be developed. Analyzing the phenology of crops using NDVI is critical for the projects. For this reason, absolute radiometric calibration of the Red and NIR bands in space-based satellite sensors is an important issue. The Göktürk-2 satellite is an earth observation satellite which was designed and built in Turkey and was launched in 2012. The Göktürk-2 satellite sensor has a resolution 2.5 meters in panchromatic and 5 meters in R/G/B/NIR bands. The absolute radiometric calibration of the Göktürk-2 satellite sensor was performed via the ground-based measurements - spectra-radiometer, sun photometer, and meteorological station- in Tuz Gölü cal/val site in 2015. In this paper, the first ground-based absolute radiometric calibration results of the Göktürk-2 satellite sensor using Tuz Gölü is demonstrated. The absolute radiometric calibration results of this paper are compared with the published cross-calibration results of the Göktürk-2 satellite sensor utilizing Landsat 8 imagery. According to the experimental comparison results, the Göktürk-2 satellite sensor coefficients for red and NIR bands

  13. ABSOLUTE RADIOMETRIC CALIBRATION OF THE GÖKTÜRK-2 SATELLITE SENSOR USING TUZ GÖLÜ (LANDNET SITE FROM NDVI PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    U. Sakarya

    2016-06-01

    Full Text Available TÜBİTAK UZAY has conducted a research study on the use of space-based satellite resources for several aspects of agriculture. Especially, there are two precision agriculture related projects: HASSAS (Widespread application of sustainable precision agriculture practices in Southeastern Anatolia Project Region (GAP Project and AKTAR (Smart Agriculture Feasibility Project. The HASSAS project aims to study development of precision agriculture practice in GAP region. Multi-spectral satellite imagery and aerial hyperspectral data along with ground measurements was collected to analyze data in an information system. AKTAR aims to develop models for irrigation, fertilization and spectral signatures of crops in Inner Anatolia. By the end of the project precision agriculture practices to control irrigation, fertilization, pesticide and estimation of crop yield will be developed. Analyzing the phenology of crops using NDVI is critical for the projects. For this reason, absolute radiometric calibration of the Red and NIR bands in space-based satellite sensors is an important issue. The Göktürk-2 satellite is an earth observation satellite which was designed and built in Turkey and was launched in 2012. The Göktürk-2 satellite sensor has a resolution 2.5 meters in panchromatic and 5 meters in R/G/B/NIR bands. The absolute radiometric calibration of the Göktürk-2 satellite sensor was performed via the ground-based measurements - spectra-radiometer, sun photometer, and meteorological station- in Tuz Gölü cal/val site in 2015. In this paper, the first ground-based absolute radiometric calibration results of the Göktürk-2 satellite sensor using Tuz Gölü is demonstrated. The absolute radiometric calibration results of this paper are compared with the published cross-calibration results of the Göktürk-2 satellite sensor utilizing Landsat 8 imagery. According to the experimental comparison results, the Göktürk-2 satellite sensor coefficients for

  14. A novel method for destriping of OCM-2 data and radiometric performance analysis for improved ocean color data products

    Science.gov (United States)

    Singh, Rakesh Kumar; Shanmugam, Palanisamy

    2018-06-01

    Despite the capability of Ocean Color Monitor aboard Oceansat-2 satellite to provide frequent, high-spatial resolution, visible and near-infrared images for scientific research on coastal zones and climate data records over the global ocean, the generation of science quality ocean color products from OCM-2 data has been hampered by serious vertical striping artifacts and poor calibration of detectors. These along-track stripes are the results of variations in the relative response of the individual detectors of the OCM-2 CCD array. The random unsystematic stripes and bandings on the scene edges affect both visual interpretation and radiometric integrity of remotely sensed data, contribute to confusion in the aerosol correction process, and multiply and propagate into higher level ocean color products generated by atmospheric correction and bio-optical algorithms. Despite a number of destriping algorithms reported in the literature, complete removal of stripes without residual effects and signal distortion in both low- and high-level products is still challenging. Here, a new operational algorithm has been developed that employs an inverted gaussian function to estimate error fraction parameters, which are uncorrelated and vary in spatial, spectral and temporal domains. The algorithm is tested on a large number of OCM-2 scenes from Arabian Sea and Bay of Bengal waters contaminated with severe stripes. The destriping effectiveness of this approach is then evaluated by means of various qualitative and quantitative analyses, and by comparison with the results of the previously reported method. Clearly, the present method is more effective in terms of removing the stripe noise while preserving the radiometric integrity of the destriped OCM-2 data. Furthermore, a preliminary time-dependent calibration of the OCM-2 sensor is performed with several match-up in-situ data to evaluate its radiometric performance for ocean color applications. OCM-2 derived water

  15. Sky camera imagery processing based on a sky classification using radiometric data

    International Nuclear Information System (INIS)

    Alonso, J.; Batlles, F.J.; López, G.; Ternero, A.

    2014-01-01

    As part of the development and expansion of CSP (concentrated solar power) technology, one of the most important operational requirements is to have complete control of all factors which may affect the quantity and quality of the solar power produced. New developments and tools in this field are focused on weather forecasting improving both operational security and electricity production. Such is the case with sky cameras, devices which are currently in use in some CSP plants and whose use is expanding in the new technology sector. Their application is mainly focused on cloud detection, estimating their movement as well as their influence on solar radiation attenuation indeed, the presence of clouds is the greatest factor involved in solar radiation attenuation. The aim of this work is the detection and analysis of clouds from images taken by a TSI-880 model sky. In order to obtain accurate image processing, three different models were created, based on a previous sky classification using radiometric data and representative sky conditions parameters. As a consequence, the sky can be classified as cloudless, partially-cloudy or overcast, delivering an average success rate of 92% in sky classification and cloud detection. - Highlights: • We developed a methodology for detection of clouds in total sky imagery (TSI-880). • A classification of sky is presented according to radiometric data and sky parameters. • The sky can be classified as cloudless, partially cloudy and overcast. • The images processing is based on the sky classification for the detection of clouds. • The average success of the developed model is around 92%

  16. Preliminary Assessment of Suomi-NPP VIIRS On-orbit Radiometric Performance

    Science.gov (United States)

    Oudrari, Hassan; DeLuccia, Frank; McIntire, Jeff; Moyer, David; Chiang, Vincent; Xiong, Xiao-xiong; Butler, James

    2012-01-01

    The Visible-Infrared Imaging Radiometer Suite (VIIRS) is a key instrument on-board the Suomi National Polar-orbiting Partnership (NPP) spacecraft that was launched on October 28th 2011. VIIRS was designed to provide moderate and imaging resolution of most of the globe twice daily. It is a wide-swath (3,040 km) cross-track scanning radiometer with spatial resolutions of 370.and 740 m at nadir for imaging and moderate bands, respectively. It has 22 spectral bands covering the spectrum between 0.412 11m and 12.01 11m, including 14 reflective solar bands (RSB), 7 thermal emissive bands (TEB), and 1 day-night band (ON B). VIIRS observations are used to generate 22 environmental data products (EORs). This paper will briefly describe NPP VIIRS calibration strategies performed by the independent government team, for the initial on-orbit Intensive Calibration and Validation (ICV) activities. In addition, this paper will provide an early assessment of the sensor on-orbit radiometric performance, such as the sensor signal to noise ratios (SNRs), dual gain transition verification, dynamic range and linearity, reflective bands calibration based on the solar diffuser (SO) and solar diffuser stability monitor (SOSM), and emissive bands calibration based on the on-board blackbody calibration (OBC). A comprehensive set of performance metrics generated during the pre-launch testing program will be compared to VIIRS on-orbit early performance, and a plan for future cal/val activities and performance enhancements will be presented.

  17. The Importance of Post-Launch, On-Orbit Absolute Radiometric Calibration for Remote Sensing Applications

    Science.gov (United States)

    Kuester, M. A.

    2015-12-01

    Remote sensing is a powerful tool for monitoring changes on the surface of the Earth at a local or global scale. The use of data sets from different sensors across many platforms, or even a single sensor over time, can bring a wealth of information when exploring anthropogenic changes to the environment. For example, variations in crop yield and health for a specific region can be detected by observing changes in the spectral signature of the particular species under study. However, changes in the atmosphere, sun illumination and viewing geometries during image capture can result in inconsistent image data, hindering automated information extraction. Additionally, an incorrect spectral radiometric calibration will lead to false or misleading results. It is therefore critical that the data being used are normalized and calibrated on a regular basis to ensure that physically derived variables are as close to truth as is possible. Although most earth observing sensors are well-calibrated in a laboratory prior to launch, a change in the radiometric response of the system is inevitable due to thermal, mechanical or electrical effects caused during the rigors of launch or by the space environment itself. Outgassing and exposure to ultra-violet radiation will also have an effect on the sensor's filter responses. Pre-launch lamps and other laboratory calibration systems can also fall short in representing the actual output of the Sun. A presentation of the differences in the results of some example cases (e.g. geology, agriculture) derived for science variables using pre- and post-launch calibration will be presented using DigitalGlobe's WorldView-3 super spectral sensor, with bands in the visible and near infrared, as well as in the shortwave infrared. Important defects caused by an incomplete (i.e. pre-launch only) calibration will be discussed using validation data where available. In addition, the benefits of using a well-validated surface reflectance product will be

  18. 14C-AMS at the Leibniz-Labor: radiometric dating and isotope research

    International Nuclear Information System (INIS)

    Grootes, Pieter M.; Nadeau, Marie-Josee; Rieck, Anke

    2004-01-01

    The Leibniz-Labor was founded to provide radiometric dating services using AMS and measured over 15 000 samples and 26 800 targets up to September 2002. Research and development have primarily been directed at improving the efficiency and reliability of AMS measurements, optimising existing sample preparation procedures for AMS and developing new ones. The standard chemical pre-treatment of organic radiocarbon samples produces often two fractions: one from which contaminants have been removed, and one in which they have been enriched. Dating both fractions reveals the degree of sample contamination. This provides a useful indication of the reliability of the sample age obtained and of the environmental conditions where the sample was taken. Upgrades to reduce maintenance include replacing four cryo- by turbo pumps, installing a deionizer loop, which keeps conductivity between 100 and 150 μS/cm to control corrosion, in the closed cooling water circuit, and developing a new sample wheel, which holds target holders with a groove and spring clip. Long term stability is demonstrated by the results obtained for IAEA reference materials, measured routinely and regularly over the years. Tests made as part of the FIRI project demonstrate that reliable measurements down to <0.1 mg C can be made

  19. Rectal cooling test in the differentiation between constipation due to rectal inertia and anismus.

    Science.gov (United States)

    Shafik, A; Shafik, I; El Sibai, O; Shafik, A A

    2007-03-01

    The differentiation between constipation due to rectal inertia and that due to outlet obstruction from non-relaxing puborectalis muscle (PRM) is problematic and not easily achieved with one diagnostic test. Therefore, we studied the hypothesis that the rectal cooling test (RCT) can effectively be used to differentiate between those two forms of constipation. The study enrolled 28 patients with constipation and abnormal transit study in whom radio-opaque markers accumulated in the rectum; 15 healthy volunteers acted as controls. Electromyographic activity of the external anal sphincter (EAS) and PRM was initially recorded. Subsequently rectal wall tone was assessed by a barostat system during rectal infusion with normal saline at 30 degrees C and at 4 degrees C with simultaneous electromyography (EMG). There was a significant increase in EMG activity of the EAS and PRM on strain- ing (panismus, in 10 of 28 patients and 0 of 15 controls. Rectal tone in controls did not respond to saline infusion at 30 degrees C, but it increased at 4 degrees C (panismus (panismus while it had no effect in the remaining patients. Lack of increase of rectal tone may be secondary to rectal inertia. According to these preliminary observations, the rectal cooling test may be useful in differentiating between rectal inertia and anismus.

  20. METHOD OF RADIOMETRIC DISTORTION CORRECTION OF MULTISPECTRAL DATA FOR THE EARTH REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    A. N. Grigoriev

    2015-07-01

    Full Text Available The paper deals with technologies of ground secondary processing of heterogeneous multispectral data. The factors of heterogeneous data include uneven illumination of objects on the Earth surface caused by different properties of the relief. A procedure for the image restoration of spectral channels by means of terrain distortion compensation is developed. The object matter of this paper is to improve the quality of the results during image restoration of areas with large and medium landforms. Methods. Researches are based on the elements of the digital image processing theory, statistical processing of the observation results and the theory of multi-dimensional arrays. Main Results. The author has introduced operations on multidimensional arrays: concatenation and elementwise division. Extended model description for input data about the area is given. The model contains all necessary data for image restoration. Correction method for multispectral data radiometric distortions of the Earth remote sensing has been developed. The method consists of two phases: construction of empirical dependences for spectral reflectance on the relief properties and restoration of spectral images according to semiempirical data. Practical Relevance. Research novelty lies in developme nt of the application theory of multidimensional arrays with respect to the processing of multispectral data, together with data on the topography and terrain objects. The results are usable for development of radiometric data correction tools. Processing is performed on the basis of a digital terrain model without carrying out ground works connected with research of the objects reflective properties.

  1. Structural and photocarrier radiometric characterization of Cu{sub x}(CdTe){sub y}O{sub z} thin films growth by reactive sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez-Hernandez, R., E-mail: ruvel2@yahoo.com.m [Division de Investigacion y Posgrado, Facultad de Ingenieria, Universidad Autonoma de Queretaro, Cerro de las Campanas S/N, Queretaro, Qro., Mexico, C.P. 76010 (Mexico); Rojas-Rodriguez, I. [Universidad Tecnologica de Queretaro, Av. Pie de la Cuesta S/N, Sn. Pedrito Penuelas, Queretaro, Qro. Mexico (Mexico); Carmona-Rodriguez, J.; Jimenez-Sandoval, S. [Centro de Investigacion y de Estudios Avanzados del IPN, Unidad Queretaro, Apartado Postal 1-798, Queretaro, Qro., Mexico C.P.76001 (Mexico); Rodriguez-Garcia, M.E. [Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriqulla, Apartado Postal 1-1010, Queretaro, Qro. Mexico (Mexico)

    2011-01-31

    This research presents a structural and photocarrier radiometric (PCR) characterization of Cu{sub x}(CdTe){sub y}O{sub z} thin films grown using reactive radiofrequency co-sputtering. Electronic distribution induced by variations in dopant concentration as a function of the position was studied using photocarrier radiometric images. Optical and structural characterization of these thin films was carried out by using micro Raman spectroscopy and X-ray diffraction. Due to its nondestructive and noncontact characteristics, the PCR is an excellent technique that permits one to obtain details of lateral electronic distribution across the sample. It was found that Cu target power influences the electronic distribution and produces different phases such as Cu{sub 2}Te and CdO.

  2. Evaluation of Radiometric and Atmospheric Correction Algorithms for Aboveground Forest Biomass Estimation Using Landsat 5 TM Data

    Directory of Open Access Journals (Sweden)

    Pablito M. López-Serrano

    2016-04-01

    Full Text Available Solar radiation is affected by absorption and emission phenomena during its downward trajectory from the Sun to the Earth’s surface and during the upward trajectory detected by satellite sensors. This leads to distortion of the ground radiometric properties (reflectance recorded by satellite images, used in this study to estimate aboveground forest biomass (AGB. Atmospherically-corrected remote sensing data can be used to estimate AGB on a global scale and with moderate effort. The objective of this study was to evaluate four atmospheric correction algorithms (for surface reflectance, ATCOR2 (Atmospheric Correction for Flat Terrain, COST (Cosine of the Sun Zenith Angle, FLAASH (Fast Line-of-sight Atmospheric Analysis of Spectral Hypercubes and 6S (Second Simulation of Satellite Signal in the Solar, and one radiometric correction algorithm (for reflectance at the sensor ToA (Apparent Reflectance at the Top of Atmosphere to estimate AGB in temperate forest in the northeast of the state of Durango, Mexico. The AGB was estimated from Landsat 5 TM imagery and ancillary information from a digital elevation model (DEM using the non-parametric multivariate adaptive regression splines (MARS technique. Field reference data for the model training were collected by systematic sampling of 99 permanent forest growth and soil research sites (SPIFyS established during the winter of 2011. The following predictor variables were identified in the MARS model: Band 7, Band 5, slope (β, Wetness Index (WI, NDVI and MSAVI2. After cross-validation, 6S was found to be the optimal model for estimating AGB (R2 = 0.71 and RMSE = 33.5 Mg·ha−1; 37.61% of the average stand biomass. We conclude that atmospheric and radiometric correction of satellite images can be used along with non-parametric techniques to estimate AGB with acceptable accuracy.

  3. Characterization of the Sonoran desert as a radiometric calibration target for Earth observing sensors

    Science.gov (United States)

    Angal, Amit; Chander, Gyanesh; Xiong, Xiaoxiong; Choi, Tae-young; Wu, Aisheng

    2011-01-01

    To provide highly accurate quantitative measurements of the Earth's surface, a comprehensive calibration and validation of the satellite sensors is required. The NASA Moderate Resolution Imaging Spectroradiometer (MODIS) Characterization Support Team, in collaboration with United States Geological Survey, Earth Resources Observation and Science Center, has previously demonstrated the use of African desert sites to monitor the long-term calibration stability of Terra MODIS and Landsat 7 (L7) Enhanced Thematic Mapper plus (ETM+). The current study focuses on evaluating the suitability of the Sonoran Desert test site for post-launch long-term radiometric calibration as well as cross-calibration purposes. Due to the lack of historical and on-going in situ ground measurements, the Sonoran Desert is not usually used for absolute calibration. An in-depth evaluation (spatial, temporal, and spectral stability) of this site using well calibrated L7 ETM+ measurements and local climatology data has been performed. The Sonoran Desert site produced spatial variability of about 3 to 5% in the reflective solar regions, and the temporal variations of the site after correction for view-geometry impacts were generally around 3%. The results demonstrate that, barring the impacts due to occasional precipitation, the Sonoran Desert site can be effectively used for cross-calibration and long-term stability monitoring of satellite sensors, thus, providing a good test site in the western hemisphere.

  4. Comparison of small n statistical tests of differential expression applied to microarrays

    Directory of Open Access Journals (Sweden)

    Lee Anna Y

    2009-02-01

    Full Text Available Abstract Background DNA microarrays provide data for genome wide patterns of expression between observation classes. Microarray studies often have small samples sizes, however, due to cost constraints or specimen availability. This can lead to poor random error estimates and inaccurate statistical tests of differential expression. We compare the performance of the standard t-test, fold change, and four small n statistical test methods designed to circumvent these problems. We report results of various normalization methods for empirical microarray data and of various random error models for simulated data. Results Three Empirical Bayes methods (CyberT, BRB, and limma t-statistics were the most effective statistical tests across simulated and both 2-colour cDNA and Affymetrix experimental data. The CyberT regularized t-statistic in particular was able to maintain expected false positive rates with simulated data showing high variances at low gene intensities, although at the cost of low true positive rates. The Local Pooled Error (LPE test introduced a bias that lowered false positive rates below theoretically expected values and had lower power relative to the top performers. The standard two-sample t-test and fold change were also found to be sub-optimal for detecting differentially expressed genes. The generalized log transformation was shown to be beneficial in improving results with certain data sets, in particular high variance cDNA data. Conclusion Pre-processing of data influences performance and the proper combination of pre-processing and statistical testing is necessary for obtaining the best results. All three Empirical Bayes methods assessed in our study are good choices for statistical tests for small n microarray studies for both Affymetrix and cDNA data. Choice of method for a particular study will depend on software and normalization preferences.

  5. Testing for Nonuniform Differential Item Functioning with Multiple Indicator Multiple Cause Models

    Science.gov (United States)

    Woods, Carol M.; Grimm, Kevin J.

    2011-01-01

    In extant literature, multiple indicator multiple cause (MIMIC) models have been presented for identifying items that display uniform differential item functioning (DIF) only, not nonuniform DIF. This article addresses, for apparently the first time, the use of MIMIC models for testing both uniform and nonuniform DIF with categorical indicators. A…

  6. Vicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System

    Directory of Open Access Journals (Sweden)

    Susana Del Pozo

    2014-02-01

    Full Text Available Combinations of unmanned aerial platforms and multispectral sensors are considered low-cost tools for detailed spatial and temporal studies addressing spectral signatures, opening a broad range of applications in remote sensing. Thus, a key step in this process is knowledge of multi-spectral sensor calibration parameters in order to identify the physical variables collected by the sensor. This paper discusses the radiometric calibration process by means of a vicarious method applied to a high-spatial resolution unmanned flight using low-cost artificial and natural covers as control and check surfaces, respectively.

  7. A radiometric method for the characterization of particulate processes in colloidal suspensions. II

    International Nuclear Information System (INIS)

    Subotic, B.

    1979-01-01

    A radiometric method for the characterization of particulate processes is verified using stable hydrosols of silver iodide. Silver iodide hydrosols satisfy the conditions required for the applications of the proposed method. Comparison shows that the values for the change of particle size measured in silver iodide hydrosols by the proposed method are in excellent agreement with the values obtained by other methods on the same systems (electron microscopy, sedimentation analysis, light scattering). This shows that the proposed method is suitable for the characterization of particulate processes in colloidal suspensions. (Auth.

  8. An in vitro study of dental enamel wear by restorative materials using radiometric method

    International Nuclear Information System (INIS)

    Adachi, Lena Katekawa

    2000-01-01

    There is an increasing demand and interest to study the dental materials wear as well as about the abrasion effect on antagonistic teeth. Due to the fact that the existent restorative materials have no specifications about their abrasiveness, it is necessary the establishment of degrees of comparison among them to support clinical application. In this work, the radiometric method was applied to study the enamel wear caused by another enamel and by restorative materials (Ceramco II, Noritake and Finesse porcelains, Artglass and Targis). The dental enamel made radioactive by irradiation at the IEA-R1m nuclear research reactor under a thermal neutron flux was submitted to wear in a machine which allows sliding motion of an antagonistic surface in contact with this radioactive enamel. The enamel wear was evaluated by measuring beta activity of 32 P transferred to water from this irradiated tooth. Results obtained indicated that dental porcelains cause pronounced enamel wear when compared with that provoked by another enamel or by resin materials. Resin materials caused less enamel wear than another enamel. Vickers microhardness data obtained for antagonistic materials showed a correlation with the wear caused to the enamel. This study allowed to conclude that the radiometric method proposed can be used satisfactorily in the evaluation of enamel wear by restorative materials. This method presents advantages due to quick responses and ease of analyses There is (author)

  9. Radiometric evaluation of granite tables in environment public in the city of Recife-PE, Brazil

    International Nuclear Information System (INIS)

    Rocha, Edilson A.; Amaral, Romilton dos S.; Santos Junior, Jose A. dos; Bezerra, Jairo D.

    2011-01-01

    Granite in Pernambuco has been used as raw-material in several utensils, amongst which, furniture and decoration objects. This granite, besides being traded internally, is also exported to Asia and Europe. Differentiated content of some radionuclides of the ( 238 U and 232 Th) and 40 K natural series above average content of other rocks is also commonly found, due to its origin and geological formation. The gamma radiation stems from the decay of the given series, followed by the 40 K, and it should not exceed the 1 mSv.y -1 limit per person of the public, according to the current radiological protection rules (ICRP, 60). This work aimed to radiometrically assess the granite tables used by the public of a well visited restaurant in the city of Recife. It is expected to contribute to the environmental monitoring and to assess the possible health risks for humans. The tables were monitored for a period of about one year. Dosimetric tablets of CaSO 4 :Dy were used. The findings showed doses ranges from the background to 4.7 mSv.y -1 , with general average of dose rate equal to 3.0 mSv.y -1 . Therefore, it was concluded that despite the average dose rates in the different granite objects studied being higher than the recommended rate, the exposure does not offer risks to their users, due to the contact time (meal time) and the levels of radioactive emission found. (author)

  10. Development of radiometric assays for quantification of enzyme activities of the key enzymes of thyroid hormones metabolism

    Czech Academy of Sciences Publication Activity Database

    Pavelka, Stanislav

    2014-01-01

    Roč. 63, Suppl.1 (2014), S133-S140 ISSN 0862-8408 R&D Projects: GA MŠk(CZ) 7AMB12SK158; GA ČR(CZ) GA304/08/0256 Institutional support: RVO:67985823 Keywords : enzyme * metabolism * radiometric assay * thyroid hormone Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition Impact factor: 1.293, year: 2014

  11. Assessing Differential Item Functioning on the Test of Relational Reasoning

    Directory of Open Access Journals (Sweden)

    Denis Dumas

    2018-03-01

    Full Text Available The test of relational reasoning (TORR is designed to assess the ability to identify complex patterns within visuospatial stimuli. The TORR is designed for use in school and university settings, and therefore, its measurement invariance across diverse groups is critical. In this investigation, a large sample, representative of a major university on key demographic variables, was collected, and the resulting data were analyzed using a multi-group, multidimensional item-response theory model-comparison procedure. No significant differential item functioning was found on any of the TORR items across any of the demographic groups of interest. This finding is interpreted as evidence of the cultural fairness of the TORR, and potential test-development choices that may have contributed to that cultural fairness are discussed.

  12. Statistical techniques applied to aerial radiometric surveys (STAARS): series introduction and the principal-components-analysis method

    International Nuclear Information System (INIS)

    Pirkle, F.L.

    1981-04-01

    STAARS is a new series which is being published to disseminate information concerning statistical procedures for interpreting aerial radiometric data. The application of a particular data interpretation technique to geologic understanding for delineating regions favorable to uranium deposition is the primary concern of STAARS. Statements concerning the utility of a technique on aerial reconnaissance data as well as detailed aerial survey data will be included

  13. Radiometric detection of metabolic activity of Paracoccidiodes brasiliensis and its susceptibility to amphotericin B and Diethylstilbestrol

    International Nuclear Information System (INIS)

    Camargo, E.E.; Sato, M.K.; Del Negro, G.M.B.; Lacaz, C.S.

    1987-01-01

    A radiometric assay system has been applied to study the metabolic activity and the effect of drugs (amphotericin B and diethylstilbestrol) on the fungus Paracoccidiodes brasiliensis ''in vitro''. The Y form of the yeast, grown in liquid Sabouraud medium was inoculated into sterile reaction vials containing the 6B aerobic medium along with 2.0μCi of 14 C-substrates. (M.A.C.) [pt

  14. Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

    Science.gov (United States)

    Choi, Taeyoung; Xiong, Xiaxiong; Chander, G.; Angal, Amit

    2009-01-01

    The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM

  15. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    Science.gov (United States)

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  16. A precise, efficient radiometric assay for bacterial growth

    International Nuclear Information System (INIS)

    Boonkitticharoen, V.; Ehrhardt, C.; Kirchner, P.T.

    1984-01-01

    The two-compartment radiometric assay for bacterial growth promised major advantages over systems in clinical use, but poor reproducibility and counting efficiency limited its application. In this method, 14-CO/sub 2/ produced by bacterial metabolism of C-14-glucose is trapped and counted on filter paper impregnated with NaOH and fluors. The authors sought to improve assay efficiency and precision through a systematic study of relevant physical and chemical factors. Improvements in efficiency (88% vs. 10%) and in precision (relative S.D. 5% vs. 40%) were produced by a) reversing growth medium and scintillator chambers to permit vigorous agitation, b) increasing NaOH quantity and using a supersaturated PPO solution and c) adding detergent to improve uniformity of NaOH-PPO mixture. Inoculum size, substrate concentration and O/sub 2/ transfer rate affected assay sensitivity but not bacterial growth rate. The authors' assay reliably detects bacterial growth for inocula of 10,000 organisms in 1 hour and for 25 organisms within 4 1/2 hours, thus surpassing other existing clinical and research methods

  17. Defined culture medium for stem cell differentiation: applicability of serum-free conditions in the mouse embryonic stem cell test.

    Science.gov (United States)

    Riebeling, Christian; Schlechter, Katharina; Buesen, Roland; Spielmann, Horst; Luch, Andreas; Seiler, Andrea

    2011-06-01

    The embryonic stem cell test (EST) is a validated method to assess the developmental toxicity potency of chemicals. It was developed to reduce animal use and allow faster testing for hazard assessment. The cells used in this method are maintained and differentiated in media containing foetal calf serum. This animal product is of considerable variation in quality, and individual batches require extensive testing for their applicability in the EST. Moreover, its production involves a large number of foetuses and possible animal suffering. We demonstrate the serum-free medium and feeder cell-free maintenance of the mouse embryonic stem cell line D3 and investigate the use of specific growth factors for induction of cardiac differentiation. Using a combination of bone morphogenetic protein-2, bone morphogenetic protein-4, activin A and ascorbic acid, embryoid bodies efficiently differentiated into contracting myocardium. Additionally, examining levels of intracellular marker proteins by flow cytometry not only confirmed differentiation into cardiomyocytes, but demonstrated significant differentiation into neuronal cells in the same time frame. Thus, this approach might allow for simultaneous detection of developmental effects on both early mesodermal and neuroectodermal differentiation. The serum-free conditions for maintenance and differentiation of D3 cells described here enhance the transferability and standardisation and hence the performance of the EST. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System

    International Nuclear Information System (INIS)

    ERMI, A.M.

    2000-01-01

    The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (VandV) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification

  19. Radiometric Evaluation of SNPP VIIRS Band M11 via Sub-Kilometer Intercomparison with Aqua MODIS Band 7 over Snowy Scenes

    Directory of Open Access Journals (Sweden)

    Mike Chu

    2018-03-01

    Full Text Available A refined intersensor comparison study is carried out to evaluate the radiometric stability of the 2257 nm channel (M11 of the first Visible Infrared Imaging Radiometer Suite (VIIRS aboard the Suomi National Polar-orbiting Partnership (SNPP satellite. This study is initiated as part of the examination into the performance of key shortwave infrared (SWIR bands for SNPP VIIRS ocean color data processing and applications, with Band M11 playing key role over turbid and inland waters. The evaluation utilizes simultaneous nadir overpasses (SNOs to compare SNPP VIIRS Band M11 against Band 7 of the MODerate-resolution Imaging Spectroradiometer (MODIS in the Aqua satellite over concurrently observed scenes. The standard result of the radiance comparison is a seemingly uncontrolled and inconsistent time series unsuitable for further analyses, in great contrast to other matching band-pairs whose radiometric comparisons are typically stable around 1.0 within 1% variation. The mismatching relative spectral response (RSR between the two respective bands, with SNPP VIIRS M11 at 2225 to 2275 nm and Aqua MODIS B7 at 2125 to 2175 nm, is demonstrated to be the cause of the large variation because of the different dependence of the spectral responses of the two bands over identical scenes. A consistent radiometric comparison time series, however, can be extracted from SNO events that occur over snowy surfaces. A customized selection and analysis procedure successfully identifies the snowy scenes within the SNO events and builds a stable comparison time series. Particularly instrumental for the success of the comparison is the use of the half-kilometer spatial resolution data of Aqua MODIS B7 that significantly enhances the statistics. The final refined time series of Aqua MODIS B7 radiance over the SNPP VIIRS M11 radiance is stable at around 0.39 within 2.5% showing no evidence of drift. The radiometric ratio near 0.39 suggests the strong presence of medium

  20. Microwave and Millimeter-Wave Radiometric Studies of Temperature, Water Vapor and Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Westwater, Edgeworth

    2011-05-06

    The importance of accurate measurements of column amounts of water vapor and cloud liquid has been well documented by scientists within the Atmospheric Radiation Measurement (ARM) Program. At the North Slope of Alaska (NSA), both microwave radiometers (MWR) and the MWRProfiler (MWRP), been used operationally by ARM for passive retrievals of the quantities: Precipitable Water Vapor (PWV) and Liquid Water Path (LWP). However, it has been convincingly shown that these instruments are inadequate to measure low amounts of PWV and LWP. In the case of water vapor, this is especially important during the Arctic winter, when PWV is frequently less than 2 mm. For low amounts of LWP (< 50 g/m{sup 2}), the MWR and MWRP retrievals have an accuracy that is also not acceptable. To address some of these needs, in March-April 2004, NOAA and ARM conducted the NSA Arctic Winter Radiometric Experiment - Water Vapor Intensive Operational Period at the ARM NSA/Adjacent Arctic Ocean (NSA/AAO) site. After this experiment, the radiometer group at NOAA moved to the Center for Environmental Technology (CET) of the Department of Electrical and Computer Engineering of the University of Colorado at Boulder. During this 2004 experiment, a total of 220 radiosondes were launched, and radiometric data from 22.235 to 380 GHz were obtained. Primary instruments included the ARM MWR and MWRP, a Global Positioning System (GPS), as well as the CET Ground-based Scanning Radiometer (GSR). We have analyzed data from these instruments to answer several questions of importance to ARM, including: (a) techniques for improved water vapor measurements; (b) improved calibration techniques during cloudy conditions; (c) the spectral response of radiometers to a variety of conditions: clear, liquid, ice, and mixed phase clouds; and (d) forward modeling of microwave and millimeter wave brightness temperatures from 22 to 380 GHz. Many of these results have been published in the open literature. During the third year of

  1. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Dillinger, P.; Harangozo, M.; Jombik, J.

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l -1 NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing 85 Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated 85 Kr ions. The developed method is simple, accurate and correct. (author)

  2. Determination of uranium and thorium contents using a 14 MeV neutron generator and a radiometric method

    International Nuclear Information System (INIS)

    Casagrande, J.A.

    1981-04-01

    A simple method was developed which can determine uranium and thorium in uranium ores, by 14MeV neutron activation and delayed neutron counting. The process can be used in field laboratories to select samples for processing. The method does not require a previous treatment of the samples and the analysis time is below 5 minutes. The detection limit of the method is about 2 ppm, when the yield of the 14MeV source has a value of 2 X 10 11 neutrons/second, and an optimized delayed neutron counter is used. A radiometric method is used determine separately the thorium content of the sample, and this result is combined with the activation one in order to obtain uranium content. The radiometric method in the counting of the 2,6 MeV gamma rays from 208 Tl using a NaI(Tl) detector. Delayed neutron counting is performed with BF 3 detectors inside a paraffin box. The problem of radioactive equilibrium does not affect thorium determination since the biggest activities of thorium daughters are much smaller than the times involved in the displacements of mineral which can give origin to the radioactive desequilibrium. (Author) [pt

  3. Algorithm for automatic image dodging of unmanned aerial vehicle images using two-dimensional radiometric spatial attributes

    Science.gov (United States)

    Li, Wenzhuo; Sun, Kaimin; Li, Deren; Bai, Ting

    2016-07-01

    Unmanned aerial vehicle (UAV) remote sensing technology has come into wide use in recent years. The poor stability of the UAV platform, however, produces more inconsistencies in hue and illumination among UAV images than other more stable platforms. Image dodging is a process used to reduce these inconsistencies caused by different imaging conditions. We propose an algorithm for automatic image dodging of UAV images using two-dimensional radiometric spatial attributes. We use object-level image smoothing to smooth foreground objects in images and acquire an overall reference background image by relative radiometric correction. We apply the Contourlet transform to separate high- and low-frequency sections for every single image, and replace the low-frequency section with the low-frequency section extracted from the corresponding region in the overall reference background image. We apply the inverse Contourlet transform to reconstruct the final dodged images. In this process, a single image must be split into reasonable block sizes with overlaps due to large pixel size. Experimental mosaic results show that our proposed method reduces the uneven distribution of hue and illumination. Moreover, it effectively eliminates dark-bright interstrip effects caused by shadows and vignetting in UAV images while maximally protecting image texture information.

  4. Installation of Radiometric Sorting throughout the Cogema-Simo Mining Complex at Lodeve. [Uranium ores

    Energy Technology Data Exchange (ETDEWEB)

    Grenier, J.; Winter, J.M.; Deville, P.

    1986-06-01

    The ores of Lodeve present no physical characteristics which permit an elimination of the lowest grade fractions, with the exception of the radioactivity and the radium which accompanies the uranium. The mine therefore turned to radiometric pebble-by-pebble sorting on a machine model M 17 of Ore Sorters who have a monopoly of this type of equipment; this permits an operation over a size range from 25 to 160 mm. Sampling of the deposit investigation of pebble samples, construction of the sorting plant and commissioning are described.

  5. Differential computation method used to calibrate the angle-centroid relationship in coaxial reverse Hartmann test

    Science.gov (United States)

    Li, Xinji; Hui, Mei; Zhao, Zhu; Liu, Ming; Dong, Liquan; Kong, Lingqin; Zhao, Yuejin

    2018-05-01

    A differential computation method is presented to improve the precision of calibration for coaxial reverse Hartmann test (RHT). In the calibration, the accuracy of the distance measurement greatly influences the surface shape test, as demonstrated in the mathematical analyses. However, high-precision absolute distance measurement is difficult in the calibration. Thus, a differential computation method that only requires the relative distance was developed. In the proposed method, a liquid crystal display screen successively displayed two regular dot matrix patterns with different dot spacing. In a special case, images on the detector exhibited similar centroid distributions during the reflector translation. Thus, the critical value of the relative displacement distance and the centroid distributions of the dots on the detector were utilized to establish the relationship between the rays at certain angles and the detector coordinates. Experiments revealed the approximately linear behavior of the centroid variation with the relative displacement distance. With the differential computation method, we increased the precision of traditional calibration 10-5 rad root mean square. The precision of the RHT was increased by approximately 100 nm.

  6. Precise quantitation of PAIgG: A new radiometric microtechnique

    International Nuclear Information System (INIS)

    Schwartz, K.A.; Gauger, J.A.; Davis, J.M.

    1990-01-01

    We report the development of a radiometric assay for platelet-bound IgG that is both sensitive and quantitative. The assay utilized 96-well millititer plates incorporating a 0.2 microns filter membrane in the bottom. A 125I-labeled monoclonal antihuman IgG, as a secondary antibody, detected the platelet-bound human IgG. Since 5 x 10(6) platelets were used for each assay, tests for platelet-bound IgG can be performed on persons with severe thrombocytopenia. For the detection of circulating antiplatelet alloantibodies, as little as 10 microliters of platelet-free plasma per assay is required. Antiplatelet IgG was quantitated by using anti-PIA1 antibody that was purified with affinity and elution and DEAE chromatography. This purified antiplatelet antibody was labeled with 125I and was used to determine the binding ratio of secondary antibody to primary antibody. Under our standard conditions, this ratio was found to be stable at approximately 0.35 over the sensitivity range of the assay. The assay can detect approximately 200 molecules of human IgG per platelet (0.1 ng of secondary antibody bound per 5 x 10(6) platelets). It has a linear range from 0 to 7,000 molecules per platelet. Quantitation of anti-PIA1 binding for platelets stored for up to 6 months under refrigeration showed no change in number of PIA1 binding sites. Clinical studies showed that 18 of 19 ITP patients had an increased number of IgG molecules per platelet as did patients with malignancy and drug-induced immune thrombocytopenia. Patients who had received multiple platelet transfusions had antiplatelet antibody in their plasma. Normal amounts of PAIgG were observed in platelets and plasma of patients with nonimmune thrombocytopenia

  7. Radiometric measurements on the fabrication of non-destructive assay standards for WIPP-Performance Demonstration Program

    International Nuclear Information System (INIS)

    Wong, A.S.; Marshall, R.S.

    1997-04-01

    The Inorganic Elemental Analysis Group of LANL has prepared several different sets of working reference materials (WRMs). These WRMs are prepared by blending quantities of nuclear materials (plutonium, americium, and enriched uranium) with diatomaceous earth. The blends are encapsulated in stainless steel cylinders. These WRMs are being measured as blind controls in neutron and gamma based non-destructive assay (NDA) instruments. Radiometric measurements on the blending homogeneity and verification on a set of sixty three plutonium based WRMs are discussed in this paper

  8. A Dataset of Three Educational Technology Experiments on Differentiation, Formative Testing and Feedback

    Science.gov (United States)

    Haelermans, Carla; Ghysels, Joris; Prince, Fernao

    2015-01-01

    This paper describes a dataset with data from three individually randomized educational technology experiments on differentiation, formative testing and feedback during one school year for a group of 8th grade students in the Netherlands, using administrative data and the online motivation questionnaire of Boekaerts. The dataset consists of pre-…

  9. MSFIA-LOV system for {sup 226}Ra isolation and pre-concentration from water samples previous radiometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez, Rogelio [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Borràs, Antoni [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Leal, Luz [Environment and Energy Department, Advanced Materials Research Center (CIMAV) S.C., Miguel de Cervantes 120, Chihuahua, Chih. 31136 (Mexico); Cerdà, Víctor [Department of Chemistry, University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain); Ferrer, Laura, E-mail: laura.ferrer@uib.es [Environmental Radioactivity Laboratory (LaboRA), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122, Palma (Spain)

    2016-03-10

    An automatic system based on multisyringe flow injection analysis (MSFIA) and lab-on-valve (LOV) flow techniques for separation and pre-concentration of {sup 226}Ra from drinking and natural water samples has been developed. The analytical protocol combines two different procedures: the Ra adsorption on MnO{sub 2} and the BaSO{sub 4} co-precipitation, achieving more selectivity especially in water samples with low radium levels. Radium is adsorbed on MnO{sub 2} deposited on macroporous of bead cellulose. Then, it is eluted with hydroxylamine to transform insoluble MnO{sub 2} to soluble Mn(II) thus freeing Ra, which is then coprecipitated with BaSO{sub 4}. The {sup 226}Ra can be directly detected in off-line mode using a low background proportional counter (LBPC) or through a liquid scintillation counter (LSC), after performing an on-line coprecipitate dissolution. Thus, the versatility of the proposed system allows the selection of the radiometric detection technique depending on the detector availability or the required response efficiency (sample number vs. response time and limit of detection). The MSFIA-LOV system improves the precision (1.7% RSD), and the extraction frequency (up to 3 h{sup −1}). Besides, it has been satisfactorily applied to different types of water matrices (tap, mineral, well and sea water). The {sup 226}Ra minimum detectable activities (LSC: 0.004 Bq L{sup −1}; LBPC: 0.02 Bq L{sup −1}) attained by this system allow to reach the guidance values proposed by the relevant international agencies e.g. WHO, EPA and EC. - Highlights: • Automatic, rapid and selective method for {sup 226}Ra extraction/pre-concentration from water. • MSFIA-LOV system performs a sample clean-up prior to {sup 226}Ra radiometric detection. • {sup 226}Ra sample preparation allows using two radiometric detectors (LBPC and LSC). • Environmental levels of {sup 226}Ra are easily quantified. • High sensitivity and selectivity are achieved, reaching the

  10. Radiometric evaluation of granite tables in environment public in the city of Recife-PE, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, Edilson A.; Amaral, Romilton dos S.; Santos Junior, Jose A. dos; Bezerra, Jairo D., E-mail: accioly.edilson@ufpe.b, E-mail: romilton@ufpe.b, E-mail: jaraujo@ufpe.b, E-mail: jairo.dias@ufpe.b [Universidade Federal de Pernambuco (RAE/DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Radioecologia

    2011-07-01

    Granite in Pernambuco has been used as raw-material in several utensils, amongst which, furniture and decoration objects. This granite, besides being traded internally, is also exported to Asia and Europe. Differentiated content of some radionuclides of the ({sup 238}U and {sup 232}Th) and {sup 40}K natural series above average content of other rocks is also commonly found, due to its origin and geological formation. The gamma radiation stems from the decay of the given series, followed by the {sup 40}K, and it should not exceed the 1 mSv.y{sup -1} limit per person of the public, according to the current radiological protection rules (ICRP, 60). This work aimed to radiometrically assess the granite tables used by the public of a well visited restaurant in the city of Recife. It is expected to contribute to the environmental monitoring and to assess the possible health risks for humans. The tables were monitored for a period of about one year. Dosimetric tablets of CaSO{sub 4}:Dy were used. The findings showed doses ranges from the background to 4.7 mSv.y{sup -1}, with general average of dose rate equal to 3.0 mSv.y{sup -1}. Therefore, it was concluded that despite the average dose rates in the different granite objects studied being higher than the recommended rate, the exposure does not offer risks to their users, due to the contact time (meal time) and the levels of radioactive emission found. (author)

  11. Testing a model of codependency for college students in Taiwan based on Bowen's concept of differentiation.

    Science.gov (United States)

    Chang, Shih-Hua

    2018-04-01

    The purpose of this study was to test a model of codependency based on Bowen's concept of differentiation for college students in Taiwan. The relations between family-of-origin dysfunction, differentiation of self, codependency traits and related symptoms including low self-esteem, relationship distress and psychological adjustment problems were examined. Data were collected from 567 college students from 2 large, urban universities in northern Taiwan. Results indicated a significantly negative relationship between levels of codependency and self-differentiation and that self-differentiation partially mediated the relationship between family-of-origin dysfunction and codependency. The implications of these findings for counselling Taiwanese college students who experience codependency traits and related symptoms as well as suggestions for future research are discussed. © 2016 International Union of Psychological Science.

  12. Fitting straight lines and planes with an application to radiometric dating

    International Nuclear Information System (INIS)

    Kent, J.T.; Watson, G.S.; Onstott, T.C.

    1990-01-01

    Conventional practice in geochronology is to fit a straight line or ''isochron'' to data consisting of two isotopic ratios by a method that takes into account that fact that both ratios are measured with error. In this paper we use matrix algebra to lay out a general method for fitting linear relations between any number of variables, all subject to errors with known variances and covariances and the well-known Newton-Raphson method to do the optimization. This leads to a good computational algorithm which may also be used e.g. to check whether coefficients in several linear relations are the same. In many fields of science one needs to fit linear relations so our method is of wide utility; its use is in no way restricted to radiometric data. (orig.)

  13. Radiometric maps of Israel - Partial contribution to the understanding of potential radon emanations

    International Nuclear Information System (INIS)

    Vulkan, U.; Shirav, M.

    1997-01-01

    An airborne radiometric survey over parts of Israel was carried out in 1981. The system was comprised from 10 Nal 4 inch x 4 inch x 16 inch detectors, arranged in 4,4 and 2 sensors, with total volume of 1560 inch 3 , and one 4 inch x 4 inch x 16 inch uplooking Nal detector. Flight nominal height was 400 feet. It was found that the Mount Scopus Group (of Senonian origin) is the main source for high uranium - phosphorite rocks of this group contain up to 150 ppm U. Comparing the eU radiometric map with a map of potential radon emanation from rock units, reveals a fair correlation - high radon emanation usually follow the distribution of the Mount Scopus Group in Israel. The correlation between the two maps is excellent over arid terrain where soil cover is missing, whereas over semi-arid - humid areas (western and northern Israel), where soil and cultivation covers are developed, the eU levels over Mount Scopus Group's outcrops are much lower due to absorption of the radiation, and do not depict the full radon potential. Detailed mapping of radon hazards usually exhibit poor correlation between airborne eU data and direct pore radon measurements, even in arid terrain. This phenomenon is attributed to the fact that a radon ''source rock'' (e.g. phosphorite) could be covered with a few up to some tenths of meters of uranium-barren rock. About 0.5 meter cover is enough to absorb all radiation, causing very low airborne eU readings, while the radon free way in this rock is about 10 meters, yielding high pore radon levels when directly measured

  14. Radiometric, geometric, and image quality assessment of ALOS AVNIR-2 and PRISM sensors

    Science.gov (United States)

    Saunier, S.; Goryl, P.; Chander, G.; Santer, R.; Bouvet, M.; Collet, B.; Mambimba, A.; Kocaman, Aksakal S.

    2010-01-01

    The Advanced Land Observing Satellite (ALOS) was launched on January 24, 2006, by a Japan Aerospace Exploration Agency (JAXA) H-IIA launcher. It carries three remote-sensing sensors: 1) the Advanced Visible and Near-Infrared Radiometer type 2 (AVNIR-2); 2) the Panchromatic Remote-Sensing Instrument for Stereo Mapping (PRISM); and 3) the Phased-Array type L-band Synthetic Aperture Radar (PALSAR). Within the framework of ALOS Data European Node, as part of the European Space Agency (ESA), the European Space Research Institute worked alongside JAXA to provide contributions to the ALOS commissioning phase plan. This paper summarizes the strategy that was adopted by ESA to define and implement a data verification plan for missions operated by external agencies; these missions are classified by the ESA as third-party missions. The ESA was supported in the design and execution of this plan by GAEL Consultant. The verification of ALOS optical data from PRISM and AVNIR-2 sensors was initiated 4 months after satellite launch, and a team of principal investigators assembled to provide technical expertise. This paper includes a description of the verification plan and summarizes the methodologies that were used for radiometric, geometric, and image quality assessment. The successful completion of the commissioning phase has led to the sensors being declared fit for operations. The consolidated measurements indicate that the radiometric calibration of the AVNIR-2 sensor is stable and agrees with the Landsat-7 Enhanced Thematic Mapper Plus and the Envisat MEdium-Resolution Imaging Spectrometer calibration. The geometrical accuracy of PRISM and AVNIR-2 products improved significantly and remains under control. The PRISM modulation transfer function is monitored for improved characterization.

  15. Simultaneous determination of effective carrier lifetime and resistivity of Si wafers using the nonlinear nature of photocarrier radiometric signals

    Science.gov (United States)

    Sun, Qiming; Melnikov, Alexander; Wang, Jing; Mandelis, Andreas

    2018-04-01

    A rigorous treatment of the nonlinear behavior of photocarrier radiometric (PCR) signals is presented theoretically and experimentally for the quantitative characterization of semiconductor photocarrier recombination and transport properties. A frequency-domain model based on the carrier rate equation and the classical carrier radiative recombination theory was developed. The derived concise expression reveals different functionalities of the PCR amplitude and phase channels: the phase bears direct quantitative correlation with the carrier effective lifetime, while the amplitude versus the estimated photocarrier density dependence can be used to extract the equilibrium majority carrier density and thus, resistivity. An experimental ‘ripple’ optical excitation mode (small modulation depth compared to the dc level) was introduced to bypass the complicated ‘modulated lifetime’ problem so as to simplify theoretical interpretation and guarantee measurement self-consistency and reliability. Two Si wafers with known resistivity values were tested to validate the method.

  16. Neuro-Spect and neuropsychological test in the differential diagnosis of dementia

    International Nuclear Information System (INIS)

    Marroni, B.M.; Louzada, A.G.; Andrea, S.A.; Raupp, A.A.; Sprinz, C.S.; Marroni, S.M.; Canani, L.C.; Zagoury, E.Z.; Borneman, C.B.

    2002-01-01

    Background/Aim: The role of the Neuro-Spect scintigraphy as a diagnostic tool in central nervous system diseases is well established. However, the simultaneous application of a neuro-psychological test (NPT) may be used to enhance the diagnostic accuracy of the test. The aim of this study was to test if the concomitant use of the NPT may be used to improve the differential diagnostic accuracy of the scintigraphy. Methods: A total of 144 cerebral perfusion studies (CPS) (Tc-ECD, 1110 MBq) were performed between March and October 2001. From this total 63 patients with non-specific complains of memory loss formed the study group. Patients with cancer, psychiatric disturbs or craniotomies were excluded. For analysis the patients were divided in 3 subgroups according to the major complain: a) memory deficit, b) depression and C) organic syndrome that included patients with cerebral stroke, occult hydrocephalus and head trauma. All patients submitted to the Neuro-Spect underwent a simultaneous NPT. The NPT included the following tests: Digit Span (WAIS-R), verbal fluency, clock drawing task, Minimental State Examination (MMSE) and Rey Auditory Verbal Learning Test (RAVLT). Well-established criteria, such as symmetry and concentration of the Tc-ECD were used for evaluation of the CPS. Concordance of the findings in the CPS and the anatomic lesion was used to reinforce the final conclusions. A scale for Alzheimer's Like Dementia (ALD) from 1 to 8 was developed (where 1=normal and 8 suggests ALD) using as reference the study of Holmann BL. Results: The NPT showed a positive correlation with the Neuro-Spect's probability scale. The tests with the best correlation were the verbal fluency (p<0.001), RAVLT and the memory recall (p<0.01). The MMSE did not show association with the Neuro-Spect probability scale. Conclusions: There is a positive association between the NPT and the Neuro-Spect. These results suggest that the NPT added to the Neuro-Spect may the be useful in the

  17. Iodine sorption of bentonite - radiometric and polarographic study

    International Nuclear Information System (INIS)

    Konirova, R.; Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    The experiments focused on kinetics of iodine retardation on bentonite, influence of aqueous phase pH, buffering properties of bentonite, etc. were carried out by batch method. Distribution coefficient KD was the criterion applied for evaluation of iodine interaction with solid phase. High sorption potential of bentonite to cationic forms of various radionuclides, resulting from relatively high cation exchange capacity, is generally known. On the other hand the inorganic anions are not adsorbed strongly to mineral surface of clays thus uptake of iodine (occurring mainly at iodide (I - ) or iodate (IO 3 - ) form under oxoic conditions) is limited. The distribution coefficients of iodine anions' sorption on bentonite R reach order of magnitude 10 -1 mL/g. In order to increase the sorption capacity of the solid phase, several additives were added to bentonite. Most of them didn't provide satisfactory results except of the addition of activated carbon, which has high surface area. Electromigration and polarographic methods were used for investigation of the redox state of iodine in aqueous phase and determination of KD values as well. Acquired results were compared with data obtained by radiometric measurements. (authors)

  18. Exploring a Black Body Source as an Absolute Radiometric Calibration Standard and Comparison with a NIST Traced Lamp Standard

    Science.gov (United States)

    Green, Robert O.; Chrien, Thomas; Sarture, Chuck

    2001-01-01

    Radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is required for the scientific research and application objectives pursued with the spectroscopic measurements. Specifically calibration is required for: inter-comparison of AVIRIS data measured at different locations and at different times; analysis of AVIRIS data with data measured by other instruments; and analysis of AVIRIS data in conjunction with computer models. The primary effect of radiometric calibration is conversion of AVIRIS instrument response values (digitized numbers, or DN) to units of absolute radiance. For example, a figure shows the instrument response spectrum measured by AVIRIS over a portion of Rogers Dry Lake, California, and another figure shows the same spectrum calibrated to radiance. Only the calibrated spectrum may be quantitatively analyzed for science research and application objectives. Since the initial development of the AVIRIS instrument-radiometric calibration has been based upon a 1000-W irradiance lamp with a calibration traced to the National Institute of Standards and Technology (NIST). There are several advantages to this irradiance-lamp calibration approach. First, the considerable effort of NIST backs up the calibration. Second, by changing the distance to the lamp, the output can closely span the radiance levels measured by AVIRIS. Third, this type of standard is widely used. Fourth, these calibrated lamps are comparatively inexpensive. Conversely, there are several disadvantages to this approach as well. First, the lamp is not a primary standard. Second, the lamp output characteristics may change in an unknown manner through time. Third, it is difficult to assess, constrain, or improve the calibration uncertainty delivered with the lamp. In an attempt to explore the effect and potentially address some of these disadvantages a set of analyses and measurements comparing an irradiance lamp with a black-body source have been completed

  19. Geologic-radiometric techniques applied for uranium prospection at the Hierro-Cayo Largo area

    International Nuclear Information System (INIS)

    Gongora, L.E.; Olivera, J.

    1995-01-01

    Using geologic-radiometric techniques uraniferous anomalies were evaluated at the Hierro-Cayo Largo area located in Pinar del Rio province. During the uranium prospection works at most promising areas, geologic itineraries and gamma ray, radon emanation spectrometric survey were done. Trenches were made and some boreholes were drilled (up to 20-30 m depth). In addition a lot of samples were taken in order to determine the amount of U, Ra, Th, y K by spectrometric techniques. As result of this investigation, a geological placing, a mineralogical and geochemical characteristic of uraniferous mineralization was possible to find out. The appropriate prospection indications for uranium exploration at Esperanza geologic zone were defined

  20. Two-stage triolein breath test differentiates pancreatic insufficiency from other causes of malabsorption

    International Nuclear Information System (INIS)

    Goff, J.S.

    1982-01-01

    In 24 patients with malabsorption, [ 14 C]triolein breath tests were conducted before and together with the administration of pancreatic enzymes (Pancrease, Johnson and Johnson, Skillman, N.J.). Eleven patients with pancreatic insufficiency had a significant rise in peak percent dose per hour 14 CO 2 excretion after Pancrease, whereas 13 patients with other causes of malabsorption had no increase in 14 CO 2 excretion (2.61 +/- 0.96 vs. 0.15 +/- 0.45, p less than 0.001). The two-stage [ 14 C]triolein breath test appears to be an accurate and simple noninvasive test of fat malabsorption that differentiates steatorrhea secondary to pancreatic insufficiency from other causes of steatorrhea

  1. Differential item functioning analysis of the Vanderbilt Expertise Test for cars.

    Science.gov (United States)

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge.

  2. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. II. Citric, tartaric, undecylenic acids

    Energy Technology Data Exchange (ETDEWEB)

    Harangozo, M.; Jombik, J.; Schiller, P. (Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta); Toelgyessy, J. (Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta)

    1981-01-01

    A method for the determination of citric, tartaric and undecylenic acids based on radiometric titration with 0.1 or 0.05 mole.l/sup -1/ NaOH was developed. As an indicator of the end point, radioactive kryptonate of glass was used. Experimental technique, results of determinations as well as other possible applications of the radioactive kryptonate of glass for end point determination in alkalimetric analyses of officinal pharmaceuticals are discussed.

  3. [Comparison of efficacy of tests for differentiation of typical and atypical strains of Yersinia pestis and Yersinia pseudotuberculosis].

    Science.gov (United States)

    Arsen'eva, T E; Lebedeva, S A; Trukhachev, A L; Vasil'eva, E A; Ivanova, V S; Bozhko, N V

    2010-01-01

    To characterize species specificity of officially recommended tests for differentiation of Yersiniapestis and Yersinia pseudotuberculosis and propose additional tests allowing for more accurate identification. Natural, laboratory and typical strains oftwo Yersinia species were studied using microbiological, molecular and biochemical methods. For PCR species-specific primers complementary to certain fragments of chromosomal DNA of each species as well as to several plasmid genes of Y. pestis were used. It was shown that such attributes of Y. pestis as form of colonies, fermentation ofrhamnose, melibiose and urea, susceptibility to diagnostic phages, nutritional requirements could be lost in pestis bacterial species or detected in pseudotuberculosis species. Such attribute as mobility as well as positive result of CoA-reaction on fraction V antigen are more reliable. Guaranteed differentiation of typical and changed according to differential tests strains is provided only by PCR-analysis with primers vlml2for/ISrev216 and JS respectively, which are homologous to certain chromosome fragments of one of two Yersinia species.

  4. Radiometric geological exploration method used in the central part of the State of Sonora

    International Nuclear Information System (INIS)

    Pacheco R, R.

    1978-01-01

    The purpose of this study is to make known the importance of the radiometric data, the physical principles on which they are based and the geological interpretation which will permit in an indirect way to select important radioactive areas in order to carry out verification studies on the ground to see if there are sufficient reasons to show any interest in these areas. Till now this work has been realized in the State of Sonora (Mexico) in an area of 51,000 Km 2 subdivided in 14 zones, numbered from 201 to 214, and for the present work the zone 208 has been selected. This Zone is located at the north-west of the City of Hermosillo, and has a total area of 3400 Km 2 which has been the object of the study by plane through systematic flights in an east-west direction, in order to obtain the configuration and interpret it from a radiometrical point of view. The obtained isorads configuration plans of 4 channels of detection are the following: total counting, potassium, bismuth and thallium as well as their relations. From the 14 verified anomalies the anomaly Noche Buena was selected in order to carry out reconnaissance surveys and preliminary and detailed geological studies. The geology of the area is represented by extrusive and intrusive igneous rocks as well as sedimentary. The uraniferous mineralization is secondary and is represented by autunite, meta-autunite and torbenite which represent an average of 200 g to 3.08 Kg. of U 3 O 8 per ton. (author)

  5. Radiometric analysis performed by the Environment Monitoring Service from IPEN (Institute of Energy and Nuclear Research), Brazil, between 1988 and 1991

    International Nuclear Information System (INIS)

    Venturini, L.; Nisti, M.B.; Pecequilo, B.R.S.

    1993-03-01

    This report presents the radiometric analyses made by the Environmental Monitoring Service from the Institute of Energy and Nuclear Research (IPEN), Brazil, in the period 1988-1991. The experimental procedures, the products analysed and their respective quantities are described. (F.E.). 11 refs, 3 tabs

  6. Accuracy of neuropsychological tests and the Neuropsychiatric Inventory in differential diagnosis between Frontotemporal dementia and Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Valéria Santoro Bahia

    Full Text Available Abstract The differential diagnosis between frontotemporal dementia (FTD and Alzheimer's disease (AD is sometimes difficult. Objectives: To verify the accuracy of neuropsychological tests and a behavioral disorders scale in the differential diagnosis between FTLD and AD. Methods: Retrospective data on 12 FTD patients and 12 probable AD patients were analyzed. The scores on neuropsychological tests (MMSE score, reverse digit span, delayed recall for drawings, semantic fluency of animals and the Neuropsychiatric Inventory (NPI in both groups were compared. Results: Both groups had similar performance on neuropsychological tests. All FTD patients and 50% of AD patients had neuropsychiatric abnormalities. The NPI score was 58.0±19.3 for the FTD patients, and 3.6±4.7 for the AD patients (p<0.01. Using a NPI cut-off score of 13, the sensitivity and specificity were 100% in this sample. The four most common neuropsychiatric disturbances in FTD patients were: apathy, aberrant motor behavior, disinhibition and eating abnormalities. Apathy and dysphoria/depression were the most common behavioral symptoms among the AD patients. Conclusions: In this study, NPI was found to be a useful tool for the differential diagnosis between FTD and AD. The neuropsychological tests commonly used in the medical office were unable to distinguish between the two groups.

  7. Recent advances in airborne radiometric technology

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1985-01-01

    Since its inception, the DOE Remote Sensing Laboratory has made dramatic innovations in airborne radiometric technology. In the past few years there have been at least four major changes in operational philosophy. (1) The helicopter is now the prime radiation survey vehicle. Surveys are conducted at low speed and low altitude, with lines spaced only a few hundred feet apart. Radiation anomalies and subtle changes in background can be readily identified. (2) Much greater emphasis is now placed on accurate, detailed analysis and interpretation of radiation data. Dramatic improvements in survey hardware and software provide much more data of considerably better quality. (3) Recent Laboratory research has been concentrated on error-free, positive identification of point radiation sources. In the past, the extent and magnitude of dispersed sources were the major concerns. (4) Integrated remote sensing has been strongly emphasized at the Laboratory in recent years. This involves the simultaneous use of radiation detectors, aerial cameras, and the multispectral scanner imagery. The synergistic effects of such data correlation are of significantly greater value in analyzing the terrestrial environment. Many of the changes in operational philosophy are directly traceable to new or dramatically improved hardware and software employed at the Laboratory. Six items have been instrumental in the above technological advances: (1) the UHF Transponder System and its predecessor, the Microwave Ranging System; (2) Model IC of the REDAR data acquisition system; (3) the development of the search algorithm; (4) continued improvements in the REDACA data analysis system; (5) deployment of polyscin sodium iodide radiation detectors; and (6) development of the Graphic Overview System

  8. Radiometric determination of density of fresh shielding concrete (in situ) in the nuclear industry

    International Nuclear Information System (INIS)

    Honig, A.

    1985-01-01

    Methods of radiometric determination of density have been in recent years elaborated in detail and successfully. But on the market no instruments are available for measuring fresh concrete when it is possible to repair inhomogeneities, if any, even before hardening, and thus to guarantee safety of biological protection of nuclear reactors. The paper describes an analog and digital radiation density meter and their application in the inspection of radiation protection concrete walls. By repairing defective, insufficiently dense locations still in the course of concrete placement it is possible to attain a laboratory quality of the concrete even under on-site conditions

  9. Thermal Infrared Radiometric Calibration of the Entire Landsat 4, 5, and 7 Archive (1982-2010)

    Science.gov (United States)

    Schott, John R.; Hook, Simon J.; Barsi, Julia A.; Markham, Brian L.; Miller, Jonathan; Padula, Francis P.; Raqueno, Nina G.

    2012-01-01

    Landsat's continuing record of the thermal state of the earth's surface represents the only long term (1982 to the present) global record with spatial scales appropriate for human scale studies (i.e., tens of meters). Temperature drives many of the physical and biological processes that impact the global and local environment. As our knowledge of, and interest in, the role of temperature on these processes have grown, the value of Landsat data to monitor trends and process has also grown. The value of the Landsat thermal data archive will continue to grow as we develop more effective ways to study the long term processes and trends affecting the planet. However, in order to take proper advantage of the thermal data, we need to be able to convert the data to surface temperatures. A critical step in this process is to have the entire archive completely and consistently calibrated into absolute radiance so that it can be atmospherically compensated to surface leaving radiance and then to surface radiometric temperature. This paper addresses the methods and procedures that have been used to perform the radiometric calibration of the earliest sizable thermal data set in the archive (Landsat 4 data). The completion of this effort along with the updated calibration of the earlier (1985 1999) Landsat 5 data, also reported here, concludes a comprehensive calibration of the Landsat thermal archive of data from 1982 to the present

  10. PSF blind test SSC, SPVC, and SVBC physics-dosimetry-metallurgy data packages

    International Nuclear Information System (INIS)

    1984-01-01

    Information is presented concerning the final PSF radiometric data; calculated spectral fluences and dosimeter activities for the metallurgical blind test irradiations at the ORR-PSF; fabrication data package for HEDL dosimetry in the ORNL Poolside Facility LWR pressure vessel mock-up irradiation; SSC-1; NUREG-CR-3457; and NUREG-CR-3295

  11. Radiometric analysis of P/sub 2/O/sub 5/ content in phosphorites from common radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    Belyakov, M A; Anderzhanov, V N; Ermolaeva, G M [Gosudarstvennyj Nauchno-Issledovatel' skij Inst. Gornokhimicheskogo Syr' ya, Moscow (USSR)

    1983-01-01

    A radiometric analysis of P/sub 2/O/sub 5/ content in phosphorites from natural radioactivity is described. A correlation between contents of phosphorus and uranium in phosphorites is a principle of the method. Potassium and thorium are interfering elements. Total radioactivity is proposed to be measured in the 0.1 to 0.6 MeV gamma radiation channel. Measurements in the channel provide a decrease in the potassium and thorium contributions to the total radioactivity, which increases an accuracy of P/sub 2/O/sub 5/ quantitative determination.

  12. Radiometric analyses of floodplain sediments at the Savannah River Plant

    International Nuclear Information System (INIS)

    Lower, M.W.

    1987-09-01

    A Comprehensive Cooling Water Study to assess the effects of reactor cooling water discharges and related reactor area liquid releases to onsite streams and the nearby Savannah River has been completed at the US Department of Energy's Savannah River Plant (SRP). Extensive radiometric analyses of man-made and naturally occurring gamma-emitting radionuclides were measured in floodplain sediment cores extracted from onsite surface streams at SRP and from the Savannah River. Gamma spectrometric analyses indicate that reactor operations contribute to floodplain radioactivity levels slightly higher than levels associated with global fallout. In locations historically unaffected by radioactive releases from SRP operations, Cs-137 concentrations were found at background and fallout levels of about 1 pCi/g. In onsite streams that provided a receptor for liquid radioactive releases from production reactor areas, volume-weighted Cs-137 concentrations ranged by core from background levels to 55 pCi/g. Savannah River sediments contained background and atmospheric fallout levels of Cs-137 only. 2 refs., 5 figs

  13. Radiometric determination of uniformity of putting paraffin on textile threads

    International Nuclear Information System (INIS)

    Ridel', Z.; Kherrmann, Eh.; Shefer, I.; Tseiner, A.

    1979-01-01

    To improve processing of the natural and synthetic fiber threads on stocking-frames, they are treated by paraffin. Paraffin is applied in the amounts nearly equal to 0.1 -1.0 g for 10 4 m of the thread's length. To determine amount of paraffin on thread and to determine uniformity if its application, a radiometric method has been developed. As a radioactive label, didocilephosphate of rare earths was used. This compound has good solubility in hydrocarbons and does not change physical properties of paraffin in the investigated field of its application as well as its concentration. It is possible to add to paraffin this radioactive label or a non-active label with subsequent its activation. Amount of paraffin, applied on a thread is determined by means of measurement of activity of thread samples of different length. Information about uniformity of paraffin application on thread have been obtained by means of autoradiography. It has been found that paraffin in mainly applied on the thread's bulges [ru

  14. Laboratory experience with radiometric detection of bacteremia with three culture media

    International Nuclear Information System (INIS)

    Wicher, K.; Koscinski, D.

    1984-01-01

    In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thioglycolate medium revealed 143 (1.1%) organisms not recovered from the 6A and 7B media. In study 2, isolates were identified in 1,135 (12.9%) of 8,759 cultures with all three media; 104 (1.2%) organisms were isolated only from the hypertonic medium. The increased yield of positive cultures in the three-medium system is likely due to the larger volume of blood cultured

  15. Children's differential susceptibility to parenting : An experimental test of “for better and for worse”

    NARCIS (Netherlands)

    Slagt, Meike; Dubas, Judith Semon; van Aken, Marcel; Ellis, Bruce J.; Dekovic, Maja

    2017-01-01

    Differential susceptibility theory proposes that a subset of individuals exist who display enhanced susceptibility to both negative (risk-promoting) and positive (development-enhancing) environments. This experiment represents the first attempt to directly test this assumption by exposing children

  16. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  17. An empirical likelihood ratio test robust to individual heterogeneity for differential expression analysis of RNA-seq.

    Science.gov (United States)

    Xu, Maoqi; Chen, Liang

    2018-01-01

    The individual sample heterogeneity is one of the biggest obstacles in biomarker identification for complex diseases such as cancers. Current statistical models to identify differentially expressed genes between disease and control groups often overlook the substantial human sample heterogeneity. Meanwhile, traditional nonparametric tests lose detailed data information and sacrifice the analysis power, although they are distribution free and robust to heterogeneity. Here, we propose an empirical likelihood ratio test with a mean-variance relationship constraint (ELTSeq) for the differential expression analysis of RNA sequencing (RNA-seq). As a distribution-free nonparametric model, ELTSeq handles individual heterogeneity by estimating an empirical probability for each observation without making any assumption about read-count distribution. It also incorporates a constraint for the read-count overdispersion, which is widely observed in RNA-seq data. ELTSeq demonstrates a significant improvement over existing methods such as edgeR, DESeq, t-tests, Wilcoxon tests and the classic empirical likelihood-ratio test when handling heterogeneous groups. It will significantly advance the transcriptomics studies of cancers and other complex disease. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Design and use of concrete pads for the calibration of radiometric survey instrumentation

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint

  19. Application of energy dispersive X-ray spectrometers with semiconductor detectors in radiometric analyses

    International Nuclear Information System (INIS)

    Jugelt, P.; Schieckel, M.

    1983-01-01

    Problems and possibilities of applying semiconductor detector spectrometers in radiometric analyses are described. A summary of the state of the art and tendencies of device engineering and spectra evaluation is given. Liquid-nitrogen cooled Li-drifted Si-detectors and high-purity Ge-detectors are compared. Semiconductor detectors working at room temperature are under development. In this connection CdTe and HgI 2 semiconductor detectors are compared. The use of small efficient computers in the spectrometer systems stimulates the development of algorithms for spectra analyses and for determining the concentration. Fields of application of energy dispersive X-ray spectrometers are X-ray diffraction and X-ray macroanalysis in investigating the structure of extensive surface regions

  20. Procedure and device for the radiometric determination of the quantity, quality and foreign substances in moved bulk materials

    International Nuclear Information System (INIS)

    Krone, C.; Jentsch, G.; Berger, J.

    1987-01-01

    This invention has to do with a procedure and device for the simultaneous radiometric determination of quantity, quality and foreign substances in moved bulk materials in particular lignite at one measuring point. The section of the bulk material discharge is transmitted by nuclides for soft and hard gamma radiation in pairs. The pulse rates are registered in pairs by means of detectors and evaluated in real-time operation

  1. Integrating prior knowledge in multiple testing under dependence with applications to detecting differential DNA methylation.

    Science.gov (United States)

    Kuan, Pei Fen; Chiang, Derek Y

    2012-09-01

    DNA methylation has emerged as an important hallmark of epigenetics. Numerous platforms including tiling arrays and next generation sequencing, and experimental protocols are available for profiling DNA methylation. Similar to other tiling array data, DNA methylation data shares the characteristics of inherent correlation structure among nearby probes. However, unlike gene expression or protein DNA binding data, the varying CpG density which gives rise to CpG island, shore and shelf definition provides exogenous information in detecting differential methylation. This article aims to introduce a robust testing and probe ranking procedure based on a nonhomogeneous hidden Markov model that incorporates the above-mentioned features for detecting differential methylation. We revisit the seminal work of Sun and Cai (2009, Journal of the Royal Statistical Society: Series B (Statistical Methodology)71, 393-424) and propose modeling the nonnull using a nonparametric symmetric distribution in two-sided hypothesis testing. We show that this model improves probe ranking and is robust to model misspecification based on extensive simulation studies. We further illustrate that our proposed framework achieves good operating characteristics as compared to commonly used methods in real DNA methylation data that aims to detect differential methylation sites. © 2012, The International Biometric Society.

  2. Multivariate analysis of subsurface radiometric data in Rongsohkham area, East Khasi Hills district, Meghalaya (India): implication on uranium exploration.

    Science.gov (United States)

    Kukreti, B M; Pandey, Pradeep; Singh, R V

    2012-08-01

    Non-coring based exploratory drilling was under taken in the sedimentary environment of Rangsohkham block, East Khasi Hills district to examine the eastern extension of existing uranium resources located at Domiasiat and Wakhyn in the Mahadek basin of Meghalaya (India). Although radiometric survey and radiometric analysis of surface grab/channel samples in the block indicate high uranium content but the gamma ray logging results of exploratory boreholes in the block, did not obtain the expected results. To understand this abrupt discontinuity between the two sets of data (surface and subsurface) multivariate statistical analysis of primordial radioactive elements (K(40), U(238) and Th(232)) was performed using the concept of representative subsurface samples, drawn from the randomly selected 11 boreholes of this block. The study was performed to a high confidence level (99%), and results are discussed for assessing the U and Th behavior in the block. Results not only confirm the continuation of three distinct geological formations in the area but also the uranium bearing potential in the Mahadek sandstone of the eastern part of Mahadek Basin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Level 0 to 1 processing of the imaging Fourier transform spectrometer GLORIA: generation of radiometrically and spectrally calibrated spectra

    Directory of Open Access Journals (Sweden)

    A. Kleinert

    2014-12-01

    Full Text Available The Gimballed Limb Observer for Radiance Imaging of the Atmosphere (GLORIA is an imaging Fourier transform spectrometer that is capable of operating on various high-altitude research aircraft. It measures the atmospheric emission in the thermal infrared spectral region in limb and nadir geometry. GLORIA consists of a classical Michelson interferometer combined with an infrared camera. The infrared detector has a usable area of 128 × 128 pixels, measuring up to 16 384 interferograms simultaneously. Imaging Fourier transform spectrometers impose a number of challenges with respect to instrument calibration and algorithm development. The optical setup with extremely high optical throughput requires the development of new methods and algorithms for spectral and radiometric calibration. Due to the vast amount of data there is a high demand for scientifically intelligent optimisation of the data processing. This paper outlines the characterisation and processing steps required for the generation of radiometrically and spectrally calibrated spectra. Methods for performance optimisation of the processing algorithm are presented. The performance of the data processing and the quality of the calibrated spectra are demonstrated for measurements collected during the first deployments of GLORIA on aircraft.

  4. Application and sensitivity investigation of Fourier transforms for microwave radiometric inversions

    Science.gov (United States)

    Holmes, J. J.; Balanis, C. A.

    1974-01-01

    Existing microwave radiometer technology now provides a suitable method for remote determination of the ocean surface's absolute brightness temperature. To extract the brightness temperature of the water from the antenna temperature equation, an unstable Fredholm integral equation of the first kind was solved. Fast Fourier Transform techniques were used to invert the integral after it is placed into a cross-correlation form. Application and verification of the methods to a two-dimensional modeling of a laboratory wave tank system were included. The instability of the Fredholm equation was then demonstrated and a restoration procedure was included which smooths the resulting oscillations. With the recent availability and advances of Fast Fourier Transform techniques, the method presented becomes very attractive in the evaluation of large quantities of data. Actual radiometric measurements of sea water are inverted using the restoration method, incorporating the advantages of the Fast Fourier Transform algorithm for computations.

  5. Time course of radiometric detection of positive blood cultures in childhood

    International Nuclear Information System (INIS)

    Meadow, W.L.; Schwartz, I.K.

    1986-01-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children

  6. Time course of radiometric detection of positive blood cultures in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Meadow, W.L.; Schwartz, I.K.

    1986-05-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children.

  7. Radiometric Normalization of Temporal Images Combining Automatic Detection of Pseudo-Invariant Features from the Distance and Similarity Spectral Measures, Density Scatterplot Analysis, and Robust Regression

    Directory of Open Access Journals (Sweden)

    Ana Paula Ferreira de Carvalho

    2013-05-01

    Full Text Available Radiometric precision is difficult to maintain in orbital images due to several factors (atmospheric conditions, Earth-sun distance, detector calibration, illumination, and viewing angles. These unwanted effects must be removed for radiometric consistency among temporal images, leaving only land-leaving radiances, for optimum change detection. A variety of relative radiometric correction techniques were developed for the correction or rectification of images, of the same area, through use of reference targets whose reflectance do not change significantly with time, i.e., pseudo-invariant features (PIFs. This paper proposes a new technique for radiometric normalization, which uses three sequential methods for an accurate PIFs selection: spectral measures of temporal data (spectral distance and similarity, density scatter plot analysis (ridge method, and robust regression. The spectral measures used are the spectral angle (Spectral Angle Mapper, SAM, spectral correlation (Spectral Correlation Mapper, SCM, and Euclidean distance. The spectral measures between the spectra at times t1 and t2 and are calculated for each pixel. After classification using threshold values, it is possible to define points with the same spectral behavior, including PIFs. The distance and similarity measures are complementary and can be calculated together. The ridge method uses a density plot generated from images acquired on different dates for the selection of PIFs. In a density plot, the invariant pixels, together, form a high-density ridge, while variant pixels (clouds and land cover changes are spread, having low density, facilitating its exclusion. Finally, the selected PIFs are subjected to a robust regression (M-estimate between pairs of temporal bands for the detection and elimination of outliers, and to obtain the optimal linear equation for a given set of target points. The robust regression is insensitive to outliers, i.e., observation that appears to deviate

  8. Justification of response time testing requirements for pressure and differential pressure sensors

    International Nuclear Information System (INIS)

    Weiss, J.M.; Mayo, C.; Swisher, V.

    1991-01-01

    This paper reports on response time testing (RTT) requirements that were imposed on pressure, differential pressure sensors as a conservative approach to insure that assumptions in the plant safety analyses were met. The purpose of this project has been to identify the need for response time testing using the bases identified in IEEE Standard 338. A combination of plant data analyses, failure modes, and effects analyses (FMEAs) was performed. Eighteen currently qualified sensor models were utilized. The results of these analyses indicate that there are only two failure modes that affect response time, not sensor output concurrently. For these failure modes, appropriate plant actions and testing techniques were identified. Safety system RTT requirements were established by IEEE Standard 338-1975. Criteria for the Periodic Testing of Class IE Power, Protection Systems, presuming the need existed for this testing. This standard established guidelines for periodic testing to verify that loop response times of installed nuclear safety-related equipment were within the limits presumed by the design basis plant transient, accident analyses. The requirements covered all passive, active components in an instrument loop, including sensors. Individual components could be tested either in groups or separately to determine the overall loop response time

  9. Study and characterization of porous germanium for radiometric measurements

    Energy Technology Data Exchange (ETDEWEB)

    Akkari, E.; Benachour, Z.; Touayar, O.; Benbrahim, J. [Activites de Recherche, Metrologie des Rayonnements, Institut National des Sciences Appliquees et de Technologie, INSAT, Tunis (Tunisia); Aouida, S.; Bessais, B. [Laboratoire de Nanomateriaux et des Systemes de l' Energie, LaNSE, Centre de Recherche et des Technologies de l' Energie, CRTEn, Hammam-Lif (Tunisia)

    2009-07-15

    The aim of this article is to study and realize a new detector based on a porous germanium (pGe) photodiode to be used as a standard for radiometric measurement in the wavelength region between 800 nm and 1700 nm. We present the development and characterization of a porous structure realized on a single-crystal substrate of p-type germanium (Ga doped) and of crystallographic orientation (100). The obtained structure allows, on the one hand, to trap the incident radiation, and on the other hand, to minimize the fluctuations of the front-face reflection coefficient of the photodiode. The first studies thus made show that it is possible to optimize, respectively, the electrical current density and the electrochemical operation time necessary for obtaining exploitable porous structures. The obtained results show that for 50 mA/cm{sup 2} and 5 min as operational parameters, we obtain a textured aspect of the porous samples that present a pyramidal form. The reflectivity study of the front surface shows a constant value of around 38% in a spectral range between 800 nm and 1700 nm approximately. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. A more general model for testing measurement invariance and differential item functioning.

    Science.gov (United States)

    Bauer, Daniel J

    2017-09-01

    The evaluation of measurement invariance is an important step in establishing the validity and comparability of measurements across individuals. Most commonly, measurement invariance has been examined using 1 of 2 primary latent variable modeling approaches: the multiple groups model or the multiple-indicator multiple-cause (MIMIC) model. Both approaches offer opportunities to detect differential item functioning within multi-item scales, and thereby to test measurement invariance, but both approaches also have significant limitations. The multiple groups model allows 1 to examine the invariance of all model parameters but only across levels of a single categorical individual difference variable (e.g., ethnicity). In contrast, the MIMIC model permits both categorical and continuous individual difference variables (e.g., sex and age) but permits only a subset of the model parameters to vary as a function of these characteristics. The current article argues that moderated nonlinear factor analysis (MNLFA) constitutes an alternative, more flexible model for evaluating measurement invariance and differential item functioning. We show that the MNLFA subsumes and combines the strengths of the multiple group and MIMIC models, allowing for a full and simultaneous assessment of measurement invariance and differential item functioning across multiple categorical and/or continuous individual difference variables. The relationships between the MNLFA model and the multiple groups and MIMIC models are shown mathematically and via an empirical demonstration. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. State of the art and trends of radiometric methods for measuring the mass per unit area

    International Nuclear Information System (INIS)

    Bernhardt, R.

    1984-01-01

    The determination of the mass per unit area by means of transmission or backscattering methods is one of the traditional radioisotope applications. Microelectronics have essentially contributed to the noticeable progress achieved in the development of radiometric instruments for mass per unit area measurements. The use of microcomputers led to both a reliable solution of the main problem of processing the measured data - the correlation of the mass per unit area value with the detector signal under nonlinear calibration conditions - and a considerable increase in the efficiency of the measuring equipment

  12. How to estimate the differential acceleration in a two-species atom interferometer to test the equivalence principle

    Energy Technology Data Exchange (ETDEWEB)

    Varoquaux, G; Nyman, R A; Geiger, R; Cheinet, P; Bouyer, P [Laboratoire Charles Fabry de l' Institut d' Optique, Campus Polytechnique, RD 128, 91127 Palaiseau (France); Landragin, A [LNE-SYRTE, UMR8630, UPMC, Observatoire de Paris, 61 avenue de l' Observatoire, 75014 Paris (France)], E-mail: philippe.bouyer@institutoptique.fr

    2009-11-15

    We propose a scheme for testing the weak equivalence principle (universality of free-fall (UFF)) using an atom-interferometric measurement of the local differential acceleration between two atomic species with a large mass ratio as test masses. An apparatus in free fall can be used to track atomic free-fall trajectories over large distances. We show how the differential acceleration can be extracted from the interferometric signal using Bayesian statistical estimation, even in the case of a large mass and laser wavelength difference. We show that this statistical estimation method does not suffer from acceleration noise of the platform and does not require repeatable experimental conditions. We specialize our discussion to a dual potassium/rubidium interferometer and extend our protocol with other atomic mixtures. Finally, we discuss the performance of the UFF test developed for the free-fall (zero-gravity) airplane in the ICE project (http://www.ice-space.fr)

  13. How to estimate the differential acceleration in a two-species atom interferometer to test the equivalence principle

    International Nuclear Information System (INIS)

    Varoquaux, G; Nyman, R A; Geiger, R; Cheinet, P; Bouyer, P; Landragin, A

    2009-01-01

    We propose a scheme for testing the weak equivalence principle (universality of free-fall (UFF)) using an atom-interferometric measurement of the local differential acceleration between two atomic species with a large mass ratio as test masses. An apparatus in free fall can be used to track atomic free-fall trajectories over large distances. We show how the differential acceleration can be extracted from the interferometric signal using Bayesian statistical estimation, even in the case of a large mass and laser wavelength difference. We show that this statistical estimation method does not suffer from acceleration noise of the platform and does not require repeatable experimental conditions. We specialize our discussion to a dual potassium/rubidium interferometer and extend our protocol with other atomic mixtures. Finally, we discuss the performance of the UFF test developed for the free-fall (zero-gravity) airplane in the ICE project (http://www.ice-space.fr).

  14. Protocol for the Differentiation of Human Induced Pluripotent Stem Cells into Mixed Cultures of Neurons and Glia for Neurotoxicity Testing.

    Science.gov (United States)

    Pistollato, Francesca; Canovas-Jorda, David; Zagoura, Dimitra; Price, Anna

    2017-06-09

    Human pluripotent stem cells can differentiate into various cell types that can be applied to human-based in vitro toxicity assays. One major advantage is that the reprogramming of somatic cells to produce human induced pluripotent stem cells (hiPSCs) avoids the ethical and legislative issues related to the use of human embryonic stem cells (hESCs). HiPSCs can be expanded and efficiently differentiated into different types of neuronal and glial cells, serving as test systems for toxicity testing and, in particular, for the assessment of different pathways involved in neurotoxicity. This work describes a protocol for the differentiation of hiPSCs into mixed cultures of neuronal and glial cells. The signaling pathways that are regulated and/or activated by neuronal differentiation are defined. This information is critical to the application of the cell model to the new toxicity testing paradigm, in which chemicals are assessed based on their ability to perturb biological pathways. As a proof of concept, rotenone, an inhibitor of mitochondrial respiratory complex I, was used to assess the activation of the Nrf2 signaling pathway, a key regulator of the antioxidant-response-element-(ARE)-driven cellular defense mechanism against oxidative stress.

  15. Differential Rearing Alters Forced Swim Test Behavior, Fluoxetine Efficacy, and Post-Test Weight Gain in Male Rats

    Science.gov (United States)

    Arndt, David L.; Peterson, Christy J.; Cain, Mary E.

    2015-01-01

    Environmental factors play a key role in the etiology of depression. The rodent forced swim test (FST) is commonly used as a preclinical model of depression, with increases in escape-directed behavior reflecting antidepressant effects, and increases in immobility reflecting behavioral despair. Environmental enrichment leads to serotonergic alterations in rats, but it is unknown whether these alterations may influence the efficacy of common antidepressants. Male Sprague-Dawley rats were reared in enriched (EC), standard (SC), or isolated (IC) conditions. Following the rearing period, fluoxetine (10 or 20 mg/kg, i.p.) was administered 23.5 hrs, 5 hrs, and 1 hr before locomotor and FST measures. Following locomotor testing and FST exposure, rats were weighed to assess fluoxetine-, FST-, and environmental condition-induced moderations in weight gain. Results revealed an antidepressant effect of environmental enrichment and a depressant effect of isolation. Regardless of significant fluoxetine effects on locomotor activity, fluoxetine generally decreased swimming and increased immobility in all three environmental conditions, with IC-fluoxetine (10 mg/kg) rats and EC-fluoxetine (20 mg/kg) rats swimming less than vehicle counterparts. Subchronic 20 mg/kg fluoxetine also induced significant weight loss, and differential rearing appeared to moderate weight gain following FST stress. These results suggest that differential rearing has the ability to alter FST behaviors, fluoxetine efficacy, and post-stressor well-being. Moreover, 20 mg/kg fluoxetine, administered subchronically, may lead to atypical effects of those commonly observed in the FST, highlighting the importance and impact of both environmental condition and dosing regimen in common animal models of depression. PMID:26154768

  16. Differential Rearing Alters Forced Swim Test Behavior, Fluoxetine Efficacy, and Post-Test Weight Gain in Male Rats.

    Directory of Open Access Journals (Sweden)

    David L Arndt

    Full Text Available Environmental factors play a key role in the etiology of depression. The rodent forced swim test (FST is commonly used as a preclinical model of depression, with increases in escape-directed behavior reflecting antidepressant effects, and increases in immobility reflecting behavioral despair. Environmental enrichment leads to serotonergic alterations in rats, but it is unknown whether these alterations may influence the efficacy of common antidepressants. Male Sprague-Dawley rats were reared in enriched (EC, standard (SC, or isolated (IC conditions. Following the rearing period, fluoxetine (10 or 20 mg/kg, i.p. was administered 23.5 hrs, 5 hrs, and 1 hr before locomotor and FST measures. Following locomotor testing and FST exposure, rats were weighed to assess fluoxetine-, FST-, and environmental condition-induced moderations in weight gain. Results revealed an antidepressant effect of environmental enrichment and a depressant effect of isolation. Regardless of significant fluoxetine effects on locomotor activity, fluoxetine generally decreased swimming and increased immobility in all three environmental conditions, with IC-fluoxetine (10 mg/kg rats and EC-fluoxetine (20 mg/kg rats swimming less than vehicle counterparts. Subchronic 20 mg/kg fluoxetine also induced significant weight loss, and differential rearing appeared to moderate weight gain following FST stress. These results suggest that differential rearing has the ability to alter FST behaviors, fluoxetine efficacy, and post-stressor well-being. Moreover, 20 mg/kg fluoxetine, administered subchronically, may lead to atypical effects of those commonly observed in the FST, highlighting the importance and impact of both environmental condition and dosing regimen in common animal models of depression.

  17. Differential Rearing Alters Forced Swim Test Behavior, Fluoxetine Efficacy, and Post-Test Weight Gain in Male Rats.

    Science.gov (United States)

    Arndt, David L; Peterson, Christy J; Cain, Mary E

    2015-01-01

    Environmental factors play a key role in the etiology of depression. The rodent forced swim test (FST) is commonly used as a preclinical model of depression, with increases in escape-directed behavior reflecting antidepressant effects, and increases in immobility reflecting behavioral despair. Environmental enrichment leads to serotonergic alterations in rats, but it is unknown whether these alterations may influence the efficacy of common antidepressants. Male Sprague-Dawley rats were reared in enriched (EC), standard (SC), or isolated (IC) conditions. Following the rearing period, fluoxetine (10 or 20 mg/kg, i.p.) was administered 23.5 hrs, 5 hrs, and 1 hr before locomotor and FST measures. Following locomotor testing and FST exposure, rats were weighed to assess fluoxetine-, FST-, and environmental condition-induced moderations in weight gain. Results revealed an antidepressant effect of environmental enrichment and a depressant effect of isolation. Regardless of significant fluoxetine effects on locomotor activity, fluoxetine generally decreased swimming and increased immobility in all three environmental conditions, with IC-fluoxetine (10 mg/kg) rats and EC-fluoxetine (20 mg/kg) rats swimming less than vehicle counterparts. Subchronic 20 mg/kg fluoxetine also induced significant weight loss, and differential rearing appeared to moderate weight gain following FST stress. These results suggest that differential rearing has the ability to alter FST behaviors, fluoxetine efficacy, and post-stressor well-being. Moreover, 20 mg/kg fluoxetine, administered subchronically, may lead to atypical effects of those commonly observed in the FST, highlighting the importance and impact of both environmental condition and dosing regimen in common animal models of depression.

  18. Statistical techniques applied to aerial radiometric surveys (STAARS): principal components analysis user's manual

    International Nuclear Information System (INIS)

    Koch, C.D.; Pirkle, F.L.; Schmidt, J.S.

    1981-01-01

    A Principal Components Analysis (PCA) has been written to aid in the interpretation of multivariate aerial radiometric data collected by the US Department of Energy (DOE) under the National Uranium Resource Evaluation (NURE) program. The variations exhibited by these data have been reduced and classified into a number of linear combinations by using the PCA program. The PCA program then generates histograms and outlier maps of the individual variates. Black and white plots can be made on a Calcomp plotter by the application of follow-up programs. All programs referred to in this guide were written for a DEC-10. From this analysis a geologist may begin to interpret the data structure. Insight into geological processes underlying the data may be obtained

  19. Finding differentially expressed genes in high dimensional data: Rank based test statistic via a distance measure.

    Science.gov (United States)

    Mathur, Sunil; Sadana, Ajit

    2015-12-01

    We present a rank-based test statistic for the identification of differentially expressed genes using a distance measure. The proposed test statistic is highly robust against extreme values and does not assume the distribution of parent population. Simulation studies show that the proposed test is more powerful than some of the commonly used methods, such as paired t-test, Wilcoxon signed rank test, and significance analysis of microarray (SAM) under certain non-normal distributions. The asymptotic distribution of the test statistic, and the p-value function are discussed. The application of proposed method is shown using a real-life data set. © The Author(s) 2011.

  20. Bolometric kinetic inductance detector technology for sub-millimeter radiometric imaging

    Science.gov (United States)

    Hassel, Juha; Timofeev, Andrey V.; Vesterinen, Visa; Sipola, Hannu; Helistö, Panu; Aikio, Mika; Mäyrä, Aki; Grönberg, Leif; Luukanen, Arttu

    2015-10-01

    Radiometric sub-millimeter imaging is a candidate technology especially in security screening applications utilizing the property of radiation in the band of 0.2 - 1.0 THz to penetrate through dielectric substances such as clothing. The challenge of the passive technology is the fact that the irradiance corresponding to the blackbody radiation is very weak in this spectral band: about two orders of magnitude below that of the infrared band. Therefore the role of the detector technology is of ultimate importance to achieve sufficient sensitivity. In this paper we present results related to our technology relying on superconducting kinetic inductance detectors operating in a thermal (bolometric) mode. The detector technology is motivated by the fact that it is naturally suitable for scalable multiplexed readout systems, and operates with relatively simple cryogenics. We will review the basic concepts of the detectors, and provide experimental figures of merit. Furthermore, we will discuss the issues related to the scale-up of our detector technology into large 2D focal plane arrays.

  1. The current perception threshold test differentiates categories of mechanical neck disorder.

    Science.gov (United States)

    Uddin, Zakir; MacDermid, Joy C; Galea, Victoria; Gross, Anita R; Pierrynowski, Michael R

    2014-07-01

    Cross-sectional discriminative analysis. To determine whether current perception threshold (CPT) can differentiate between categories of patients with mechanical neck disorders (MNDs). Neck pain is the third most common musculoskeletal disorder and affects a third of all adults each year. It can present as neck pain without musculoskeletal signs, neck pain with musculoskeletal signs but no neurological signs, or neck pain with neurological signs. CPT testing can assess altered sensory perception that may reflect neurological changes. Patients with MNDs (n = 106) were classified into 3 groups, based on a standardized musculoskeletal examination process performed by an experienced physiotherapist who was blinded to CPT scores. The 3 groups were defined as neck pain without musculoskeletal signs (MND I) (n = 60), neck pain with musculoskeletal signs (MND II) (n = 29), and neck pain with neurological signs (MND III) (n = 17). A rapid protocol of CPT testing was performed at 3 frequencies (5, 250, and 2000 Hz), using 3 dermatomal locations on the hand. A 1-way analysis of variance with post hoc comparison and effect sizes was calculated to compare the mean CPT scores between the groups. A binary logistic-regression model was used to predict probability of higher CPT in MND III and to create a receiver-operating-characteristic curve. Mean CPT differed significantly across the 3 MND groups (MND I, 9.7; MND II, 10.6; and MND III, 11.8; Pabnormal CPT in MND III had an estimated 73% sensitivity and 81% specificity; the odds ratio was 11.5 (P = .001) for the differentiation capacity of CPT between MND II and III, with a cutoff of 11. The area under the receiver-operating-characteristic curve was 0.84 (95% confidence interval: 0.72, 0.96; P<.001). CPT testing has moderate discriminatory accuracy, specificity, and sensitivity for classification of MND categories into neck pain with or without neurological signs. J Orthop Sports Phys Ther 2014;44(7):532-540. Epub 10 May 2014

  2. Aerial radiometric and magnetic reconnaissance survey of portions of Arizona--New Mexico, Nogales Quadrangle

    International Nuclear Information System (INIS)

    1978-11-01

    The results of a high-sensitivity aerial gamma-ray spectrometer and magnetometer survey of the Nogales Quadrangle, Arizona, are presented. Statistical and geological analysis of the radiometric data revealed 47 uranium anomalies worthy of field checking as possible prospects. Twenty-one anomalies suggest the presence of vein-type uranium in acid intrusives, and 16 anomalies may denote the same type of mineralization in acid volcanics. These anomalies also mark source areas for possible sedimentary deposits. Nine anomalies may represent sedimentary uranium, but many of these may be anomalous clastics deposited in low-background material. The ranges that appear most favorable for uranium mineralization are the Quinlan, Sierrita, Pajarito, Atascosa, Santa Rita, Patagonia, and Huachuca Mountains

  3. Digital radiography density measurements in differentiation between periapical granulomas and radicular cysts.

    Science.gov (United States)

    Rózyło-Kalinowska, Ingrid

    2007-05-01

    The distinction between radicular cysts and apical granulomas is a matter of considerable importance in making a treatment decision. Because there are no clearly defined radiographic criteria, the distinction is made on the grounds of size. However, it has been suggested that cysts can be distinguished from granulomas on the basis of their radiometric density. The results of previous studies have proved conflicting. To determine possibilities of application of digital radiography density measurements in differentiation of periapical granulomas and radicular cysts of inflammatory origin. The material consisted of 355 digital periapical radiograms obtained using Digora, RVG and Dixi 2 digital radiography systems in patients aged 20 to 84, divided into two groups: 259 granulomas and 102 radicular cysts. By means of Digora 2.0 software there were measured maximum and minimum densities along a line, then there was calculated the difference between maximum and minimum density. The largest dimensions of the lesions were measured - perpendicular and parallel to the root canal axis. It was proved that to some extent it was possible to differentiate cystic granulomas and radicular cysts on the basis of the difference between maximum and minimum density in linear measurement - when the difference exceeded 85.6 the lesion was a cyst and when it was below 45.9 a granuloma was diagnosed. Combination of two criteria - the calculated difference between densities and the largest dimension of a lesion, increased diagnostic possibilities of radiological differentiation of granulomas and radicular cysts.

  4. Second-line tests in the differential diagnosis of ACTH-dependent Cushing's syndrome.

    Science.gov (United States)

    Barbot, Mattia; Trementino, Laura; Zilio, Marialuisa; Ceccato, Filippo; Albiger, Nora; Daniele, Andrea; Frigo, Anna Chiara; Mardari, Rodica; Rolma, Giuseppe; Boscaro, Marco; Arnaldi, Giorgio; Scaroni, Carla

    2016-10-01

    Diagnosing Cushing's syndrome (CS) can be a challenge, especially in ACTH-dependent CS, when it comes to detecting the origin of ACTH secretion. Retrospective data were collected on 170 patients with ACTH-dependent CS (149 CD, 21 EAS) referring to two endocrinology units, focusing on three non-invasive tests: dexamethasone 8 mg overnight challenge (HDDST); corticotrophin-releasing hormone (CRH) assay and the desmopressin (DDAVP) test. Patients with EAS were slightly older and had higher ACTH, serum and urinary cortisol levels than patients with CD (p 52.7 % below the basal level suggested a pituitary origin with a SE of 88 % (95 % CI 81-93) and a SP of 90 % (95 % CI 68-99). There were no cases of EAS with positive responses to both these tests. Increases in ACTH and cortisol levels after the DDAVP test were also higher in CD than in EAS (p < 0.01), though the SE and SP were lower. Patients with CD showed a stronger response to HDDST and CRH, and the adopted cut-offs showed a good SE and SP in discriminating them from patients with EAS. Concordant tests indicated CD when positive, whereas no response to either test was highly suggestive of EAS. The DDAVP test was of limited utility in the diagnostic phase. In conclusion, the choice of tests may play an important part in the differential diagnosis of ACTH-dependent CS.

  5. Radiometric analysis of the longwave infrared channel of the Thematic Mapper on LANDSAT 4 and 5

    Science.gov (United States)

    Schott, John R.; Volchok, William J.; Biegel, Joseph D.

    1986-01-01

    The first objective was to evaluate the postlaunch radiometric calibration of the LANDSAT Thematic Mapper (TM) band 6 data. The second objective was to determine to what extent surface temperatures could be computed from the TM and 6 data using atmospheric propagation models. To accomplish this, ground truth data were compared to a single TM-4 band 6 data set. This comparison indicated satisfactory agreement over a narrow temperature range. The atmospheric propagation model (modified LOWTRAN 5A) was used to predict surface temperature values based on the radiance at the spacecraft. The aircraft data were calibrated using a multi-altitude profile calibration technique which had been extensively tested in previous studies. This aircraft calibration permitted measurement of surface temperatures based on the radiance reaching the aircraft. When these temperature values are evaluated, an error in the satellite's ability to predict surface temperatures can be estimated. This study indicated that by carefully accounting for various sensor calibration and atmospheric propagation effects, and expected error (1 standard deviation) in surface temperature would be 0.9 K. This assumes no error in surface emissivity and no sampling error due to target location. These results indicate that the satellite calibration is within nominal limits to within this study's ability to measure error.

  6. Standard operational radiation protection instructions for process instrumentation and control engineering applying radiometric equipment containing sealed sources

    International Nuclear Information System (INIS)

    1989-01-01

    According to article 16(3) of the Ordinance on the Implementation of Atomic Safety and Radiation Protection of 11 October 1984, operational radiation protection instructions have to be worked out for each type of nuclear energy application. Based on the valid legal provisions of the GDR and on experience and knowledge gained in practice, the most important operational instructions and procedures for the operation of radiometric equipment containing sealed sources were compiled. The example should enable the management to make the instructions directly applicable and, if necessary, to modify or supplement them

  7. Radiometric method for the characterization of particulate processes in colloidal suspensions. II. Experimental verification of the method

    Energy Technology Data Exchange (ETDEWEB)

    Subotic, B. [Institut Rudjer Boskovic, Zagreb (Yugoslavia)

    1979-09-15

    A radiometric method for the characterization of particulate processes is verified using stable hydrosols of silver iodide. Silver iodide hydrosols satisfy the conditions required for the applications of the proposed method. Comparison shows that the values for the change of particle size measured in silver iodide hydrosols by the proposed method are in excellent agreement with the values obtained by other methods on the same systems (electron microscopy, sedimentation analysis, light scattering). This shows that the proposed method is suitable for the characterization of particulate processes in colloidal suspensions. (Auth.).

  8. A test of the California competency-based differentiated role model.

    Science.gov (United States)

    Keating, Sarah B; Rutledge, Dana N; Sargent, Arlene; Walker, Polly

    2003-01-01

    To address the incongruence between the expectations of nursing service and education in California, the Education Industry Interface Task Force of the California Strategic Planning Committee for Nursing developed descriptions to assist employers and educators in clearly differentiating practice and educational competencies. The completion of the Competency-Based Role Differentiation Model resulted in the need to test the model for its utility in the service setting, in education, and for career planning for nurses. Three alpha demonstration sites were selected based on representative geographical regions of California. The sites were composed of tri-partnerships consisting of a medical center, an associate degree in nursing program, and a baccalaureate nursing program. Observers rated senior students and new graduates in medical-surgical units on their behaviors in teacher and leadership care provider and care coordinator roles. The alpha demonstration study results were as expected. That is, senior students practice predominantly at a novice level in teacher and management/leadership care provider functions and new graduates practice predominately at the competent level. New graduates are more likely to take on novice and competent care coordinator roles. The CBRDM may be useful for practice and education settings to evaluate student and nurse performance, to define role expectations, and to identify the preparation necessary for the roles. It is useful for all of nursing as it continues to define its levels of practice and their relationship to on-the-job performance, curriculum development, and carrier planning.

  9. Unibert - PC software for radiometric level gauging - the LB440 measuring system

    International Nuclear Information System (INIS)

    Mann, H.; Bickert, M.

    2001-01-01

    In almost all industrial branches radiometric measuring systems are being used today for a lot of different tasks. The most common field of this application are level gauging measurements by use of gamma radiation, i.e. for level detection as well as for level gauging over ranges of up to several meters. For our level gauge measuring system LB440 we developed a clearly arranged PC software, which allows starting, measuring and service of the level gauge. Over the RS232-interface the industrial computer can be connected with a Laptop or PC. The software is a supplemental or even a substitute for the operation over the frontpanel. The measuring system can be completely controlled by the Unibert PC-Software, realised by LabVIEW 5.1.1, which offers an interactive graphical user interface. The same functionality as in the ''embedded - software'' is available, completed with some additional functions. (orig.) [de

  10. Serum neutralization as a differential serological test for classical swine fever virus and other pestivirus infections

    Directory of Open Access Journals (Sweden)

    Paredes J.C.M.

    1999-01-01

    Full Text Available Serum neutralization tests (SN were performed against classical swine fever virus (CSFV, bovine viral diarrhea virus (BVDV and border disease virus (BDV on samples of swine serum collected for screening of antibodies to CSFV, in order to determine the SN value as a differential serological test. Ninety-nine sera out of a sample of 16,664 were positive for antibodies to pestiviruses in an ELISA test which did not distinguish antibodies to different pestiviruses. When submitted to SN, 81 sera were positive for CSFV antibodies only. In 17 sera, crossreactive antibodies to either CSFV, BVDV or BDV were detected. In most of these sera (13 out of 17 the differences between SN titres against the three viruses were not sufficient to estimate which was the most likely antibody-inducing virus. It was concluded that, for the SN to be useful in such differentiation, it is essential to examine a sample which must include a representative number of sera from the same farm where suspect animals were detected. When isolated serum samples are examined, such as those obtained with the sampling strategy adopted here, the SN may give rise to inconclusive results.

  11. High resolution aeromagnetic and radiometric survey in the Hokusatsu district, Japan; Hokusatsu Kushikino chiiki ni okeru kobunkaino kuchu jiki hoshano tansa kekka ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Hishida, H; Yoshioka, K [Metal Mining Agency of Japan, Tokyo (Japan)

    1997-10-22

    In FY 1996, aeromagnetic and radiometric survey was performed in the whole area of Hokusatsu district using a helicopter fixed with a stinger mount system with high density 200 m line spacing at low altitude of 80 m, which was the first in Japan. Based on the existing geological maps, Landsat TM data and radiometric data, lithologies and geological structures were extracted in response to individual magnetic characteristics in the whole magnetic map. Obtained geological characteristics are as follows. Straight magnetic anomalies suggested volcanic lava flows. Isolated ring-shaped magnetic anomalies suggested intrusive rocks. Ring-shaped weak magnetic anomalies suggested the centers of volcanoes. Wide range intense magnetic anomalies were caused by deep intrusive rocks. Wide range weak magnetic anomalies were caused by dissipation of magnetite due to hydrothermal alteration. Faults and fracture zones were recognized as linear configurations of magnetic anomaly and divided magnetic anomalies. Based on these results, local geological structures, hydrothermal alterations, and mineralization of known ore deposits were interpreted. 6 refs., 5 figs.

  12. Radiometric and Instrumental Neutron Activation Analysis (INAA) of environmental specimens: lacustrine sediments from Danube Delta

    International Nuclear Information System (INIS)

    Duliu, Octavian G.

    2002-01-01

    specificity analytical methods such as Instrumental Neutron Activation Analysis (INAA) could evidence more than 40 different elements at concentrations about ppm or lower. Unwanted events as atmospheric nuclear tests and Chernobyl accident discharged a great amount of radioactive 137 Cs that once fixed into sediments represents an excellent tracer for natural processes such as sediment transport, accumulation and redistribution during the last 40-50 years. For multielemental investigation of environmental samples such as soil, sediments, water or various minerals INAA is one of the most suitable technique. Presumably pollutants elements such as Cr, Co, Zn, As, Sb and Br as well as REE that could be easily determined by INAA are helpful indicators of the source as well as of the mechanism of deposition and incorporation of these components. Investigated in correlation with radiocesium distribution as well as some natural trace elements such as REE, Sc or Hf, their vertical profiles in sediments allows a rapid reconstruction of the history of recent pollution processes. Radiometric and INAA measurements have been performed 'in tandem' for sediments collected from different lakes located in both Fluvial (western part) and Fluvio-maritime (eastern part and the Razelm-Sinoe lacustrine complex) sections of the Danube Delta, i.e. Lung, Mesteru, Matita, Furtuna and Merhei as well as Razelm and Leahova, respectively. A review of these investigations concerning the vertical profiles of 4 major elements (Na, K, Ca and Fe), 15 trace elements (Rb, Cs, Ba, Sc, La, Ce, Sm, Eu, Tb, Yb, Lu, Th, U, Hf and Ta) as well as of 6 potential pollutants (Zn, Cr, Co, As, Sb and Br) in four lakes (Lung, Furtuna, Mester and Matita) together with anthropogenic 134 Cs and 137 Cs is presented. All these results reveal the great potential of radiometric as well as INAA in environmental as well as in geological investigations. (author)

  13. The construction of a radiometric calibration facility at Lanseria Airport, Republic of South Africa

    International Nuclear Information System (INIS)

    Corner, B.; Smit, C.J.B.

    1983-08-01

    The construction of standard sources suitable for the calibration of airborne and truck-mounted gamma-spectrometer systems is described. Four sources were built, three of which were doped with preselected quantities of uranium, thorium or potassium. A fourth source was left barren so as to provide a measure of the background radiation in the area. The sources are 8 m in diameter, 0,35 m thick and are recessed into the disused northern portion of runway 17 at Lanseria Airport, north of Johannesburg. Adopted concentrations of the major radioelements in the sources are: 6,10 % k 2 O in the potasssium source, 67,0 ppm U 3 O 8 in the uranium source (radiometric), 158 ppm ThO 2 in the thorium source

  14. Revisiting the paper “Using radiometric surface temperature for surface energy flux estimation in Mediterranean drylands from a two-source perspective”

    DEFF Research Database (Denmark)

    Kustas, William P.; Nieto, Hector; Morillas, Laura

    2016-01-01

    The recent paper by Morillas et al. [Morillas, L. et al. Using radiometric surface temperature for surface energy flux estimation in Mediterranean drylands from a two-source perspective, Remote Sens. Environ. 136, 234–246, 2013] evaluates the two-source model (TSM) of Norman et al. (1995) with re......The recent paper by Morillas et al. [Morillas, L. et al. Using radiometric surface temperature for surface energy flux estimation in Mediterranean drylands from a two-source perspective, Remote Sens. Environ. 136, 234–246, 2013] evaluates the two-source model (TSM) of Norman et al. (1995......) with revisions by Kustas and Norman (1999) over a semiarid tussock grassland site in southeastern Spain. The TSM - in its current incarnation, the two-source energy balance model (TSEB) - was applied to this landscape using ground-based infrared radiometer sensors to estimate both the composite surface...... greenness and local leaf area index values as well as modifications to the coefficients of the soil resistance formulation to account for the very rough (rocky) soil surface conditions with a clumped canopy. This indicates that both limitations in remote estimates of biophysical indicators of the canopy...

  15. The clinical utility of naturalistic action test in differentiating mild cognitive impairment from early dementia in memory clinic.

    Science.gov (United States)

    Bruce, Irene; Ntlholang, Ontefetse; Crosby, Lisa; Cunningham, Conal; Lawlor, Brian

    2016-03-01

    This study aimed to examine the validity of the Naturalistic Action Test in differentiating Mild Cognitive Impairment from early dementia compared to clinical diagnosis and ascertain Naturalistic Action Test cut-off points. This was a cross-sectional study of 70 consecutive patients diagnosed with Mild Cognitive Impairment attending the memory clinic in St James's Hospital, Dublin, Ireland. Patients with a diagnosis of Mild Cognitive Impairment who attended for routine annual assessment were asked to participate in the study. The Naturalistic Action Test was carried out after the patient had completed their routine assessment in the clinic. The Area under the Curve, AUC ± SE was 0.808 ± 0.058, p Cognitive Impairment in our study (PPV 50%, NPV 91%, sensitivity 78%, specificity 73% and accuracy of 74%). There was discrepancy in 18 patients using the new cut-off point (≥11 for Mild Cognitive Impairment vs ≤10 for dementia). The Naturalistic Action Test is a useful tool that can increase diagnostic accuracy in differentiating Mild Cognitive Impairment from early dementia. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Analysis of airborne radiometric data. Volume 2. Description, listing, and operating instructions for the code DELPHI/MAZAS. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sperling, M.; Shreve, D.C.

    1978-12-01

    The computer code DELPHI is an interactive English language command system for the analysis of airborne radiometric data. The code includes modules for data reduction, data simulation, time filtering, data adjustment and graphical presentation of the results. DELPHI is implemented in FORTRAN on a DEC-10 computer. This volume gives a brief set of operations instructions, samples of the output obtained from hard copies of the display on a Tektronix terminal and finally a listing of the code.

  17. Analysis of airborne radiometric data. Volume 2. Description, listing, and operating instructions for the code DELPHI/MAZAS. Final report

    International Nuclear Information System (INIS)

    Sperling, M.; Shreve, D.C.

    1978-01-01

    The computer code DELPHI is an interactive English language command system for the analysis of airborne radiometric data. The code includes modules for data reduction, data simulation, time filtering, data adjustment and graphical presentation of the results. DELPHI is implemented in FORTRAN on a DEC-10 computer. This volume gives a brief set of operations instructions, samples of the output obtained from hard copies of the display on a Tektronix terminal and finally a listing of the code

  18. Accelerator physics and radiometric properties of superconducting wavelength shifters; Beschleunigerphysik und radiometrische Eigenschaften supraleitender Wellenlaengenschieber

    Energy Technology Data Exchange (ETDEWEB)

    Scheer, Michael

    2008-11-17

    Subject of this thesis is the operation of wave-length shifters at electron storage rings and their use in radiometry. The basic aspects of the radiometry, the technical requirements, the influence of wave-length shifters on the storage ring, and results of first measurements are presented for a device installed at BESSY. Most of the calculations are carried out by the program WAVE, which has been developed within this thesis. WAVE allows to calculate the synchrotron radiation spectra of wavelength shifters within an relative uncertainty of 1/100000. The properties of wave-length shifters in terms of accelerator physics as well as a generating function for symplectic tracking calculations can also be calculated by WAVE. The later was implemented in the tracking code BETA to investigate the influence of insertion devices on the dynamic aperture and emittance of the storage ring. These studies led to the concept of alternating low- and high-beta-sections at BESSY-II, which allow to operate superconducting insertion devices without a significant distortion of the magnetic optics. To investigate the experimental aspects of the radiometry at wave-length shifters, a program based on the Monte-Carlo-code GEANT4 has been developed. It allows to simulate the radiometrical measurements and the absorption properties of detectors. With the developed codes first radiometrical measurements by the PTB have been analysed. A comparison of measurements and calculations show a reasonable agreement with deviations of about five percent in the spectral range of 40-60 keV behind a 1-mm-Cu filter. A better agreement was found between 20 keV and 80 keV without Cu filter. In this case the measured data agreed within a systematic uncertainty of two percent with the results of the calculations. (orig.)

  19. Microwave radiometric aircraft observations of the Fabry-Perot interference fringes of an ice-water system

    Science.gov (United States)

    Harrington, R. F.; Swift, C. T.; Fedors, J. C.

    1980-01-01

    Airborne stepped-frequency microwave radiometer (SFMR) observations of the Fabry-Perot interference fringes of ice-water systems are discussed. The microwave emissivity at normal incidence of a smooth layered dielectric medium over a semi-infinite dielectric medium is examined for the case of ice over water as a function of ice thickness and attenuation coefficient, and the presence of quarter-wavelength oscillations in emissivity as the ice thickness and frequency are varied is pointed out. Experimental observations of pronounced quarter-wavelength oscillations in radiometric brightness temperature due to the Fabry-Perot interference fringes over smooth sea ice and lake ice varying in roughness as the radiometer frequencies were scanned are then presented.

  20. The absolute radiometric calibration of the advanced very high resolution radiometer

    Science.gov (United States)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-01-01

    An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

  1. The absolute radiometric calibration of the advanced very high resolution radiometer

    Science.gov (United States)

    Slater, P. N.; Teillet, P. M.; Ding, Y.

    1988-10-01

    An increasing number of remote sensing investigations require radiometrically calibrated imagery from NOAA Advanced Very High Resolution Radiation (AVHRR) sensors. Although a prelaunch calibration is done for these sensors, there is no capability for monitoring any changes in the in-flight absolute calibration for the visible and near infrared spectral channels. Hence, the possibility of using the reflectance-based method developed at White Sands for in-orbit calibration of LANDSAT Thematic Mapper (TM) and SPOT Haute Resolution Visible (HVR) data to calibrate the AVHRR sensor was investigated. Three diffrent approaches were considered: Method 1 - ground and atmospheric measurements and reference to another calibrated satellite sensor; Method 2 - ground and atmospheric measurements with no reference to another sensor; and Method 3 - no ground and atmospheric measurements but reference to another satellite sensor. The purpose is to describe an investigation on the use of Method 2 to calibrate NOAA-9 AVHRR channels 1 and 2 with the help of ground and atmospheric measurements at Rogers (dry) Lake, Edwards Air Force Base (EAFB) in the Mojave desert of California.

  2. A comparison of radiometric correction techniques in the evaluation of the relationship between LST and NDVI in Landsat imagery.

    Science.gov (United States)

    Tan, Kok Chooi; Lim, Hwee San; Matjafri, Mohd Zubir; Abdullah, Khiruddin

    2012-06-01

    Atmospheric corrections for multi-temporal optical satellite images are necessary, especially in change detection analyses, such as normalized difference vegetation index (NDVI) rationing. Abrupt change detection analysis using remote-sensing techniques requires radiometric congruity and atmospheric correction to monitor terrestrial surfaces over time. Two atmospheric correction methods were used for this study: relative radiometric normalization and the simplified method for atmospheric correction (SMAC) in the solar spectrum. A multi-temporal data set consisting of two sets of Landsat images from the period between 1991 and 2002 of Penang Island, Malaysia, was used to compare NDVI maps, which were generated using the proposed atmospheric correction methods. Land surface temperature (LST) was retrieved using ATCOR3_T in PCI Geomatica 10.1 image processing software. Linear regression analysis was utilized to analyze the relationship between NDVI and LST. This study reveals that both of the proposed atmospheric correction methods yielded high accuracy through examination of the linear correlation coefficients. To check for the accuracy of the equation obtained through linear regression analysis for every single satellite image, 20 points were randomly chosen. The results showed that the SMAC method yielded a constant value (in terms of error) to predict the NDVI value from linear regression analysis-derived equation. The errors (average) from both proposed atmospheric correction methods were less than 10%.

  3. The water deprivation test and a potential role for the arginine vasopressin precursor copeptin to differentiate diabetes insipidus from primary polydipsia

    NARCIS (Netherlands)

    de Fost, M.; Oussaada, S. M.; Endert, E.; Linthorst, G. E.; Serlie, M. J.; Soeters, M. R.; DeVries, J. H.; Bisschop, P. H.; Fliers, E.

    2015-01-01

    The water deprivation test is the gold standard test to differentiate central or nephrogenic diabetes insipidus (DI) from primary polydipsia (PP) in patients with polyuria and polydipsia. Few studies have addressed the diagnostic performance of this test. The aim of this retrospective cohort study

  4. Radon exhalation and radiometric prospecting on rocks associated with Cu-U mineralizations in the Singhbhum shear zone, Bihar

    Energy Technology Data Exchange (ETDEWEB)

    Sengupta, D.; Kumar, Rajeev; Singh, A.K.; Prasad, Rajendra E-mail: aptolrp@amu.up.nic.in

    2001-11-01

    The Singhbhum thrust belt is a 200 km long arcuate orogenic belt in Bihar, eastern India. The huge mineral resources, viz. copper, uranium, magnetite, apatite and molybdenite, etc., make it significant from an economic as well as a geological point of view. The belt hosts three types of mineralization: sulphides of copper and other metals, uranium oxides and apatite-magnetite. Several distinct geological episodes are responsible for the evolution of mineralization and the thrust zone itself. Extensive and reliable radiometric prospecting and assaying have been carried out by us for the past 5 years from Dhobani in the east to Turamdih in the west of the Singhbhum shear zone. The present work indicates uranium mineralization in the Pathargora-Rakha area presently being mined for copper and also within areas in the vicinity of Bhatin. Studies on radon emanation have also been undertaken in some parts of the shear zone which indicate reasonably high radon emanation of the soils and rocks studied. This suggests the need for regular monitoring and suitable controls on the mine environment (air quality) and its vicinity. Radon emanation studies coupled with gamma-ray spectrometry and the subsequent modelling of the radiometric and radon measurements will help in the application of radon as a geophysical tracer in exploration of radioactive ore bodies and in radon risk assessment as well as in delineating active and passive faults and even in petroleum exploration.

  5. Differentiation of schizophrenia patients from healthy subjects by mismatch negativity and neuropsychological tests.

    Directory of Open Access Journals (Sweden)

    Yi-Ting Lin

    Full Text Available BACKGROUND: Schizophrenia is a heterogeneous disorder with diverse presentations. The current and the proposed DSM-V diagnostic system remains phenomenologically based, despite the fact that several neurobiological and neuropsychological markers have been identified. A multivariate approach has better diagnostic utility than a single marker method. In this study, the mismatch negativity (MMN deficit of schizophrenia was first replicated in a Han Chinese population, and then the MMN was combined with several neuropsychological measurements to differentiate schizophrenia patients from healthy subjects. METHODOLOGY/PRINCIPAL FINDINGS: 120 schizophrenia patients and 76 healthy controls were recruited. Each subject received examinations for duration MMN, Continuous Performance Test, Wisconsin Card Sorting Test, and Wechsler Adult Intelligence Scale Third Edition (WAIS-III. The MMN was compared between cases and controls, and important covariates were investigated. Schizophrenia patients had significantly reduced MMN amplitudes, and MMN decreased with increasing age in both patient and control groups. None of the neuropsychological indices correlated with MMN. Predictive multivariate logistic regression models using the MMN and neuropsychological measurements as predictors were developed. Four predictors, including MMN at electrode FCz and three scores from the WAIS-III (Arithmetic, Block Design, and Performance IQ were retained in the final predictive model. The model performed well in differentiating patients from healthy subjects (percentage of concordant pairs: 90.5%. CONCLUSIONS/SIGNIFICANCE: MMN deficits were found in Han Chinese schizophrenia patients. The multivariate approach combining biomarkers from different modalities such as electrophysiology and neuropsychology had a better diagnostic utility.

  6. Measurement of particle emission in automobil exhaust - application of continuous radiometric aerosol measurement to the emission of diesel engines

    International Nuclear Information System (INIS)

    Krasenbrink, A.; Georgi, B.

    1989-01-01

    The well-known method of measuring continuously dust by β-absorption is transferred to the problem of particle emission in automobile exhaust. With two similar dust-monitors FH62 having different sampling air flow rates and two low-pressure impactors the reliability of radiometric mass determination was verified. First static experiments with diesel soot showed the necessity of a dilution system, a new mass calibration with regard to the changed β-absorptivity and a quicker calculation of concentration for realtime measurements. (orig.) [de

  7. Radiometric titration of officinal radiopharmaceuticals using radioactive kryptonates as end-point indicators. I. Salicylic, acetylosalicylic, benzoic acids

    Energy Technology Data Exchange (ETDEWEB)

    Toelgyessy, J; Dillinger, P [Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia). Chemickotechnologicka Fakulta; Harangozo, M; Jombik, J [Komenskeho Univ., Bratislava (Czechoslovakia). Farmaceuticka Fakulta

    1980-01-01

    A method for the determination of salicylic, acetylsalicylic and benzoic acids in officinal pharmaceutical based on radiometric titration with 0.1 mol.l/sup -1/ NaOH was developed. The end-point was detected with the aid of radioactive glass kryptonate. After the end-point, the excess titrant attacks the glass surface layers and this results in releasing /sup 85/Kr, and consequently, in decreasing the radioactivity of the kryptonate employed. The radioactive kryptonate used as an indicator was prepared by the bombardment of glass with accelerated /sup 85/Kr ions. The developed method is simple, accurate and correct.

  8. 210Pb/226Ra disequilibria in otoliths of blue grenadier, (Macruronus novaezelandiae); problems associated with radiometric aging

    International Nuclear Information System (INIS)

    Fenton, G.E.; Ritz, D.A.

    1990-01-01

    Otoliths from blue grenadier (Macruronus novaezelandiae), which had been aged previously by annuli analysis, were analysed for the naturally occurring radionuclides 210 Pb and 226 Ra in an attempt to independently verify their age. It is concluded that the radiometric technique could not be applied to determine age because the results showed that 226 Ra was not incorporated at a constant rate throughout the life of M. novaezelandiae. Uptake of 226 Ra was greater in juveniles than in adult fish. This was probably due to the juvenile phase inhabiting inshore/estuarine waters. 20 refs., 1 tab., 2 figs

  9. Measuring instrument for the determination of dust concentrations. [air filter with. beta. radiometric gage

    Energy Technology Data Exchange (ETDEWEB)

    Dresia, H; Spohr, F

    1975-05-22

    The measuring instrument enables a continuous determination of the dust concentration or total dust content in gases on the basis of the radiometric mass determination of dusts. The partial current method is employed, with the gas fetched through a filter cell with a topped intake by a suction pump. A filter band to take up the dust deposit is continuously driven through the filter cell. The filter point and the measuring point with a ..beta..-radionuclide and a detector are both inside the filter cell. The filter cell is sealed all around, at the entrance and exit of the filter band. The band itself acts as a seal. The filter band also has borders strengthened with, e.g., plastic strips which engage the drive. The widths of the slits are adjustable in height.

  10. Effects of integration time on in-water radiometric profiles.

    Science.gov (United States)

    D'Alimonte, Davide; Zibordi, Giuseppe; Kajiyama, Tamito

    2018-03-05

    This work investigates the effects of integration time on in-water downward irradiance E d , upward irradiance E u and upwelling radiance L u profile data acquired with free-fall hyperspectral systems. Analyzed quantities are the subsurface value and the diffuse attenuation coefficient derived by applying linear and non-linear regression schemes. Case studies include oligotrophic waters (Case-1), as well as waters dominated by Colored Dissolved Organic Matter (CDOM) and Non-Algal Particles (NAP). Assuming a 24-bit digitization, measurements resulting from the accumulation of photons over integration times varying between 8 and 2048ms are evaluated at depths corresponding to: 1) the beginning of each integration interval (Fst); 2) the end of each integration interval (Lst); 3) the averages of Fst and Lst values (Avg); and finally 4) the values weighted accounting for the diffuse attenuation coefficient of water (Wgt). Statistical figures show that the effects of integration time can bias results well above 5% as a function of the depth definition. Results indicate the validity of the Wgt depth definition and the fair applicability of the Avg one. Instead, both the Fst and Lst depths should not be adopted since they may introduce pronounced biases in E u and L u regression products for highly absorbing waters. Finally, the study reconfirms the relevance of combining multiple radiometric casts into a single profile to increase precision of regression products.

  11. Brand positioning strategies : an expiremental test ot two types of benefit differentiation

    OpenAIRE

    Hem, Alexander Farestvedt; Teslo, Per Christian Strand

    2012-01-01

    The purpose of this study is to examine associative- and instrumental benefit differentiation based on secondary associations as part of brand positioning. The field of brand positioning has been subject to extensive research, however, differentiation based on secondary associations and differences between instrumental- and associative benefit differentiation has received less attention. Instrumental benefit differentiation relates to benefits that are linked directly to product performance, ...

  12. The Utility of the Wisconsin Card Sorting Test in Differential Diagnosis of Cognitive Disorders in Iranian Psychiatric Patients and Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Razieh Hashemi, MA

    2011-09-01

    Full Text Available Objective: The Wisconsin Test Card Sorting Test (WCST is a neuropsychological test that has been suggested as a more specific test for frontal lobes dysfunctions. This study was designed to determine whether WCST is able to differentiate between Iranian psychiatric patients with cognitive disorders and normal subjects, and whether WCST scores are related to severity of symptoms in depressive and schizophrenic patients.Method: Participants were four groups: schizophrenics with positive symptoms (n=25; schizophrenics with negative symptoms (n=25; major depressives (n=25; and normal subjects (n=25. All subjects were tested individually using WCST. To analyze the data, various descriptive statistics, ANOVA, t-test and multiple regression analysis were used.Results: Regarding the number of categories (P<0.001 and the rate of perseverative errors (P<0.01, according to the results, the normal subjects performed significantly better than patient groups on WCST, although the differences between patient groups were not significant. Our results also showed that greater positive or depressive symptoms were not associated with poorer scores on WCST performance. Only the level of severity of negative symptoms predicted scores on perseverative errors.Conclusion: It is concluded that WCST can differentiate Iranian psychiatric patients with cognitive disorders from normal subjects, but it is not able to clearly differentiate schizophrenic patients with negative symptoms from those with positive symptoms and depressives. Only severity of negative symptoms affects WCST performance

  13. X-ray radiometric analysis of lead and zinc concentrates using germanium radiation detector

    International Nuclear Information System (INIS)

    Vajgachev, A.A.; Mamysh, V.A.; Mil'chakov, V.I.; Shchekin, K.I.; Berezkin, V.V.

    1975-01-01

    The results of determination of lead, zinc and iron in lead and zinc concentrates by the X-ray-radiometric method with the use of germanium semiconductor detector are presented. In the experiments the 57 Co source and tritium-zirconium target were used. The activity of 57 Co was 2 mc. The area of the germanium detector employed was 5g mm 2 , its thickness - 2.3 mm. In lead concentrates zinc and iron were determined from the direct intensity of K-series radiation. In the analysis of zinc concentrates the same conditions of recording and excitation were used as in the case of lead concentrates, but the measurements were conducted in saturated layers. It is demonstrated that the use of germanium semiconductor detectors in combination with the suggested methods of measurements makes it possible to perform determination of iron, zinc and lead in zinc and lead concentrates with permissible error

  14. From SED HI concept to Pleiades FM detection unit measurements

    Science.gov (United States)

    Renard, Christophe; Dantes, Didier; Neveu, Claude; Lamard, Jean-Luc; Oudinot, Matthieu; Materne, Alex

    2017-11-01

    The first flight model PLEIADES high resolution instrument under Thales Alenia Space development, on behalf of CNES, is currently in integration and test phases. Based on the SED HI detection unit concept, PLEIADES detection unit has been fully qualified before the integration at telescope level. The main radiometric performances have been measured on engineering and first flight models. This paper presents the results of performances obtained on the both models. After a recall of the SED HI concept, the design and performances of the main elements (charge coupled detectors, focal plane and video processing unit), detection unit radiometric performances are presented and compared to the instrument specifications for the panchromatic and multispectral bands. The performances treated are the following: - video signal characteristics, - dark signal level and dark signal non uniformity, - photo-response non uniformity, - non linearity and differential non linearity, - temporal and spatial noises regarding system definitions PLEIADES detection unit allows tuning of different functions: reference and sampling time positioning, anti-blooming level, gain value, TDI line number. These parameters are presented with their associated criteria of optimisation to achieve system radiometric performances and their sensitivities on radiometric performances. All the results of the measurements performed by Thales Alenia Space on the PLEIADES detection units demonstrate the high potential of the SED HI concept for Earth high resolution observation system allowing optimised performances at instrument and satellite levels.

  15. Preliminary results of radiometric measurements of clear air and cloud brightness (antenna) temperatures at 37GHz

    Science.gov (United States)

    Arakelyan, A. K.; Hambaryan, A. K.; Arakelyan, A. A.

    2012-05-01

    In this paper the results of polarization measurements of clear air and clouds brightness temperatures at 37GHz are presented. The results were obtained during the measurements carried out in Armenia from the measuring complex built under the framework of ISTC Projects A-872 and A-1524. The measurements were carried out at vertical and horizontal polarizations, under various angles of sensing by Ka-band combined scatterometric-radiometric system (ArtAr-37) developed and built by ECOSERV Remote Observation Centre Co.Ltd. under the framework of the above Projects. In the paper structural and operational features of the utilized system and the whole measuring complex will be considered and discussed as well.

  16. Spectrally and Radiometrically Stable Wide-Band on Board Calibration Source for In-Flight Data Validation in Imaging Spectroscopy Applications

    Science.gov (United States)

    Coles, J. B.; Richardson, Brandon S.; Eastwood, Michael L.; Sarture, Charles M.; Quetin, Gregory R.; Hernandez, Marco A.; Kroll, Linley A.; Nolte, Scott H.; Porter, Michael D.; Green, Robert O.

    2011-01-01

    The quality of the quantitative spectral data collected by an imaging spectrometer instrument is critically dependent upon the accuracy of the spectral and radiometric calibration of the system. In order for the collected spectra to be scientifically useful, the calibration of the instrument must be precisely known not only prior to but during data collection. Thus, in addition to a rigorous in-lab calibration procedure, the airborne instruments designed and built by the NASA/JPL Imaging Spectroscopy Group incorporate an on board calibrator (OBC) system with the instrument to provide auxiliary in-use system calibration data. The output of the OBC source illuminates a target panel on the backside of the foreoptics shutter both before and after data collection. The OBC and in-lab calibration data sets are then used to validate and post-process the collected spectral image data. The resulting accuracy of the spectrometer output data is therefore integrally dependent upon the stability of the OBC source. In this paper we describe the design and application of the latest iteration of this novel device developed at NASA/JPL which integrates a halogen-cycle source with a precisely designed fiber coupling system and a fiber-based intensity monitoring feedback loop. The OBC source in this Airborne Testbed Spectrometer was run over a period of 15 hours while both the radiometric and spectral stabilities of the output were measured and demonstrated stability to within 1% of nominal.

  17. DIFFERENTIATION BETWEEN Staphylococcus aureus, S. intermedius AND S. hyicus USING PHENOTYPICAL TESTS AND PCR

    Directory of Open Access Journals (Sweden)

    E. A. GANDRA

    2009-01-01

    Full Text Available

    The aim of this work was to compare the use of two phenotypical tests (beta-galactosidase and acriflavine sensitivity and PCR for the coa and nuc gene sequences, for the identification of three species of coagulase positive staphylococcus (CPS: S. aureus, S. intermedius and S. hyicus. Sixty five staphylococcus isolates, previously characterized as CPS through the coagulase, thermonuclease and catalase production tests and Gram staining, were identified at species level using the beta-galactosidase production tests and sensitivity to acriflavine (7 g.mL-1. At the same time, the DNA of these isolates was extracted and amplified by PCR, using primers for the coa gene, specific for S. aureus, and for the nuc gene, specific for S. intermedius and for S. hyicus. It was possible to differentiate the three species of Staphylococcus through phenotypical tests as well as through the molecular technique. There was no difference in discriminatory power between the two techniques used, but the reproducibility and reliability of the technique based on PCR make this technique more precise.

  18. Radiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approach

    Directory of Open Access Journals (Sweden)

    Carolina Barrientos

    2016-07-01

    Full Text Available The absolute radiometric calibration of a satellite sensor is the critical factor that ensures the usefulness of the acquired data for quantitative applications on remote sensing. This work presents the results of the first cross-calibration of the sensor on board the Sistema Satelital de Observación de la Tierra (SSOT Chilean satellite or Air Force Satellite FASat-C. RapidEye-MSI was chosen as the reference sensor, and a simultaneous Nadir Overpass Approach (SNO was applied. The biases caused by differences in the spectral responses of both instruments were compensated through an adjustment factor derived from EO-1 Hyperion data. Through this method, the variations affecting the radiometric response of New AstroSat Optical Modular Instrument (NAOMI-1, have been corrected based on collections over the Frenchman Flat calibration site. The results of a preliminary evaluation of the pre-flight and updated coefficients have shown a significant improvement in the accuracy of at-sensor radiances and TOA reflectances: an average agreement of 2.63% (RMSE was achieved for the multispectral bands of both instruments. This research will provide a basis for the continuity of calibration and validation tasks of future Chilean space missions.

  19. Optimal design of sampling and mapping schemes in the radiometric exploration of Chipilapa, El Salvador (Geo-statistics)

    International Nuclear Information System (INIS)

    Balcazar G, M.; Flores R, J.H.

    1992-01-01

    As part of the knowledge about the radiometric surface exploration, carried out in the geothermal field of Chipilapa, El Salvador, its were considered the geo-statistical parameters starting from the calculated variogram of the field data, being that the maxim distance of correlation of the samples in 'radon' in the different observation addresses (N-S, E-W, N W-S E, N E-S W), it was of 121 mts for the monitoring grill in future prospectus in the same area. Being derived of it an optimization (minimum cost) in the spacing of the field samples by means of geo-statistical techniques, without losing the detection of the anomaly. (Author)

  20. A radiometric method for the determination of cationic detergents with the aid of Rose Bengal labelled with 131I

    International Nuclear Information System (INIS)

    Lengyel, J.; Krtil, J.; Vecernik, J.

    1983-01-01

    A novel radiometric method for the determination of cationic detergents represented by carbetoxypentadecyltrimethylammonium bromide (Septonex) is described. The method is based on the extraction of an ion associate Septonex-Rose Bengal from an alkaline medium into chloroform. Rose Bengal labelled with 131 I ( 131 I-RB) was used as a radioreagent. The 131 I activity in the extract is proportional to the cationic detergent concentration in the solution to be analyzed. The optimum conditions for the determination of Septonex were found and the composition of the extractable complexes Rose Bengal-Septonex was determined. (author)

  1. Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer

    Directory of Open Access Journals (Sweden)

    C. Monte

    2014-01-01

    Atmosphere is an airborne, imaging, infrared Fourier transform spectrometer that applies the limb-imaging technique to perform trace gas and temperature measurements in the Earth's atmosphere with three-dimensional resolution. To ensure the traceability of these measurements to the International Temperature Scale and thereby to an absolute radiance scale, GLORIA carries an on-board calibration system. Basically, it consists of two identical large-area and high-emissivity infrared radiators, which can be continuously and independently operated at two adjustable temperatures in a range from −50 °C to 0 °C during flight. Here we describe the radiometric and thermometric characterization and calibration of the in-flight calibration system at the Reduced Background Calibration Facility of the Physikalisch-Technische Bundesanstalt. This was performed with a standard uncertainty of less than 110 mK. Extensive investigations of the system concerning its absolute radiation temperature and spectral radiance, its temperature homogeneity and its short- and long-term stability are discussed. The traceability chain of these measurements is presented.

  2. A W-Band Radiometer with the Offset Parabolic Antenna for Radiometric Measurements

    Directory of Open Access Journals (Sweden)

    Li Wu

    2016-01-01

    Full Text Available This paper deals with the development of a W-band noise-adding radiometer which combines the millimeter-wave (MMW radiometric measurements with a high-resolution imager. The offset parabolic antenna is presented to achieve an accurate measurement and a high resolution. To reduce the cross-polarization level of the antenna, a multimode feed horn with a multistep structure is proposed to match the focal region fields of the reflector. It has advantages over the corrugated horns in lower mass and easier manufacturing. In addition, due to an unavoidable settling time for the noise-adding radiometer output signal passing through the low-pass filter, a theoretical criterion for the optimum duty cycle determination to reject extraneous contributions from the transient is proposed in this paper. The appropriate duty cycle threshold is 0.33 for the developed W-band radiometer. Also, a geometric correction method is presented to correct the obtained passive image suffering from a distortion for a better image interpretation. Preliminary experimental results are given to illustrate and verify the presented techniques.

  3. Radiometric inter-sensor cross-calibration uncertainty using a traceable high accuracy reference hyperspectral imager

    Science.gov (United States)

    Gorroño, Javier; Banks, Andrew C.; Fox, Nigel P.; Underwood, Craig

    2017-08-01

    Optical earth observation (EO) satellite sensors generally suffer from drifts and biases relative to their pre-launch calibration, caused by launch and/or time in the space environment. This places a severe limitation on the fundamental reliability and accuracy that can be assigned to satellite derived information, and is particularly critical for long time base studies for climate change and enabling interoperability and Analysis Ready Data. The proposed TRUTHS (Traceable Radiometry Underpinning Terrestrial and Helio-Studies) mission is explicitly designed to address this issue through re-calibrating itself directly to a primary standard of the international system of units (SI) in-orbit and then through the extension of this SI-traceability to other sensors through in-flight cross-calibration using a selection of Committee on Earth Observation Satellites (CEOS) recommended test sites. Where the characteristics of the sensor under test allows, this will result in a significant improvement in accuracy. This paper describes a set of tools, algorithms and methodologies that have been developed and used in order to estimate the radiometric uncertainty achievable for an indicative target sensor through in-flight cross-calibration using a well-calibrated hyperspectral SI-traceable reference sensor with observational characteristics such as TRUTHS. In this study, Multi-Spectral Imager (MSI) of Sentinel-2 and Landsat-8 Operational Land Imager (OLI) is evaluated as an example, however the analysis is readily translatable to larger-footprint sensors such as Sentinel-3 Ocean and Land Colour Instrument (OLCI) and Visible Infrared Imaging Radiometer Suite (VIIRS). This study considers the criticality of the instrumental and observational characteristics on pixel level reflectance factors, within a defined spatial region of interest (ROI) within the target site. It quantifies the main uncertainty contributors in the spectral, spatial, and temporal domains. The resultant tool

  4. Comparison of accelerator and radiometric radiocarbon measurements obtained from Late Devensian Lateglacial lake sediments from Llyn Gwernan, North Wales, UK

    International Nuclear Information System (INIS)

    Lowe, J.J.; Lowe, S.; Fowler, A.J.

    1988-01-01

    Accelerator mass spectrometry measurements of the radiocarbon activity of various chemical fractions prepared from Late Devensian Lateglacial lake sediments from the site of Llyn Gwernan, near Cader Idris. North Wales are presented and assessed. These are compared with radiocarbon measurements obtained by radiometric (decay) counting which were reported earlier from the same site and are considered in the light of pollen-stratigraphic information. The potensial advantages of accelerator radiocarbon measurements to the assessment of the chronology and correlation of Lateglacial lake sediments are evaluated

  5. Rapid susceptibility testing of Mycobacterium tuberculosis by bioluminescence assay of mycobacterial ATP

    International Nuclear Information System (INIS)

    Nilsson, L.E.; Hoffner, S.E.; Ansehn, S.

    1988-01-01

    Mycobacterial growth was monitored by bioluminescence assay of mycobacterial ATP. Cultures of Mycobacterium tuberculosis H37Rv and of 25 clinical isolates of the same species were exposed to serial dilutions of ethambutol, isoniazid, rifampin, and streptomycin. A suppression of ATP, indicating growth inhibition, occurred for susceptible but not resistant strains within 5 to 7 days of incubation. Breakpoint concentrations between susceptibility and resistance were determined by comparing these results with those obtained by reference techniques. Full agreement was found in 99% of the assays with the resistance ratio method on Lowenstein-Jensen medium, and 98% of the assays were in full agreement with the radiometric system (BACTEC). A main advantage of the bioluminescence method is its rapidity, with results available as fast as with the radiometric system but at a lower cost and without the need for radioactive culture medium. The method provides kinetic data concerning drug effects within available in vivo drug concentrations and has great potential for both rapid routine susceptibility testing and research applications in studies of drug effects on mycobacteria

  6. The fourth phase of the radiative transfer model intercomparison (RAMI) exercise: Actual canopy scenarios and conformity testing

    Czech Academy of Sciences Publication Activity Database

    Widlowski, J. L.; Mio, C.; Disney, M.; Adams, J.; Andredakis, I.; Atzberger, C.; Brennan, J.; Busetto, L.; Chelle, M.; Ceccherini, G.; Colombo, R.; Coté, J. F.; Eenmaee, A.; Essery, R.; Gastellu-Etchegorry, J. P.; Gobron, N.; Grau, E.; Haverd, V.; Homolová, Lucie; Huang, H.; Hunt, L.; Kobayashi, H.; Koetz, B.; Kuusk, A.; Kuusk, J.; Lang, M.; Lewis, P. E.; Lovell, J. L.; Malenovský, Zbyněk; Meroni, M.; Morsdorf, F.; Mottus, M.; Ni-Meister, W.; Pinty, B.; Rautiainen, M.; Schlerf, M.; Somers, B.; Stuckens, J.; Verstraete, M. M.; Yang, W.; Zhao, F.; Zenone, T.

    2015-01-01

    Roč. 169, nov (2015), s. 418-437 ISSN 0034-4257 Institutional support: RVO:67179843 Keywords : forest reflectance model * absolute radiometric calibration * remote-sensing data * Conformity testing * Radiative transfer * Model benchmarking * 3D virtual plant canopy * Digital hemispherical photography * Optical remote sensing * Shared risk * Guarded acceptance * gcos * iso -13528 Subject RIV: EH - Ecology, Behaviour Impact factor: 5.881, year: 2015

  7. Validation of differential gene expression algorithms: Application comparing fold-change estimation to hypothesis testing

    Directory of Open Access Journals (Sweden)

    Bickel David R

    2010-01-01

    performance. The posterior predictive assessment corroborates these findings. Conclusions Algorithms for detecting differential gene expression may be compared by estimating each algorithm's error in predicting expression ratios, whether such ratios are defined across microarray channels or between two independent groups. According to two distinct estimators of prediction error, algorithms using hierarchical models outperform the other algorithms of the study. The fact that fold-change shrinkage performed as well as conventional model selection criteria calls for investigating algorithms that combine the strengths of significance testing and fold-change estimation.

  8. Unmanned aerial vehicles ('drones') as tools for small scale radiometric surveys

    International Nuclear Information System (INIS)

    Luff, R.; Stöhlker, U.; Bossew, P.

    2017-01-01

    An UAV has been developed by the Federal Office for Radiation Protection (BfS) and tested in the Chernobyl exclusion zone in September 2016. A commercially available hexacopter has been equipped with a 1.5 cm³ CZT gamma spectrometric detector (μSPEC), GPS, data processing unit (Rasperry PI with Linux) and Wi-Fi for data transmission to the ground base. Optionally a camera can be carried. The system records gamma dose rate every 2 seconds and gamma spectra every 10 minutes. The total cost of the system is significantly below 10k€ which includes the detector (6k€), data acquisition system (0.2k€) and the UAV (1.2k€). The system is very mobile, easy to set up and to operate in the field. Results are plausible and easy to interpret, spatial resolution of the gamma dose rate on the ground is surprisingly high. Measurement results from the Chernobyl exclusion zone show that the sensitivity of the detector allows radiation survey in areas where the dose rate level is above 0.3 μSv/h. Limitation of the small system are the relatively short operation range of a few 100 m and the lack of an altimeter to assure constant flight altitude above ground. Among the results of the exercise were that a high gamma dose rate gradient in the field can be well identified and the observation that the measured gamma dose rate depends relatively little on the flight altitude between 3 and about 15 meters above ground, for a large scale contamination field. As a conclusion, the use of UAVs for radiometric surveys is a promising and viable complement to traditional air-borne reconnaissance for small areas, and an alternative to ground-based surveys in case of high radiation levels or difficult access. (author)

  9. Unmanned aerial vehicles ('drones') as tools for small scale radiometric surveys

    Energy Technology Data Exchange (ETDEWEB)

    Luff, R.; Stöhlker, U.; Bossew, P., E-mail: rluff@bfs.de [German Federal Office for Radiation Protection, Salzgitter (Germany)

    2017-07-01

    An UAV has been developed by the Federal Office for Radiation Protection (BfS) and tested in the Chernobyl exclusion zone in September 2016. A commercially available hexacopter has been equipped with a 1.5 cm³ CZT gamma spectrometric detector (μSPEC), GPS, data processing unit (Rasperry PI with Linux) and Wi-Fi for data transmission to the ground base. Optionally a camera can be carried. The system records gamma dose rate every 2 seconds and gamma spectra every 10 minutes. The total cost of the system is significantly below 10k€ which includes the detector (6k€), data acquisition system (0.2k€) and the UAV (1.2k€). The system is very mobile, easy to set up and to operate in the field. Results are plausible and easy to interpret, spatial resolution of the gamma dose rate on the ground is surprisingly high. Measurement results from the Chernobyl exclusion zone show that the sensitivity of the detector allows radiation survey in areas where the dose rate level is above 0.3 μSv/h. Limitation of the small system are the relatively short operation range of a few 100 m and the lack of an altimeter to assure constant flight altitude above ground. Among the results of the exercise were that a high gamma dose rate gradient in the field can be well identified and the observation that the measured gamma dose rate depends relatively little on the flight altitude between 3 and about 15 meters above ground, for a large scale contamination field. As a conclusion, the use of UAVs for radiometric surveys is a promising and viable complement to traditional air-borne reconnaissance for small areas, and an alternative to ground-based surveys in case of high radiation levels or difficult access. (author)

  10. Differential equations for dummies

    CERN Document Server

    Holzner, Steven

    2008-01-01

    The fun and easy way to understand and solve complex equations Many of the fundamental laws of physics, chemistry, biology, and economics can be formulated as differential equations. This plain-English guide explores the many applications of this mathematical tool and shows how differential equations can help us understand the world around us. Differential Equations For Dummies is the perfect companion for a college differential equations course and is an ideal supplemental resource for other calculus classes as well as science and engineering courses. It offers step-by-step techniques, practical tips, numerous exercises, and clear, concise examples to help readers improve their differential equation-solving skills and boost their test scores.

  11. Inference for High-dimensional Differential Correlation Matrices.

    Science.gov (United States)

    Cai, T Tony; Zhang, Anru

    2016-01-01

    Motivated by differential co-expression analysis in genomics, we consider in this paper estimation and testing of high-dimensional differential correlation matrices. An adaptive thresholding procedure is introduced and theoretical guarantees are given. Minimax rate of convergence is established and the proposed estimator is shown to be adaptively rate-optimal over collections of paired correlation matrices with approximately sparse differences. Simulation results show that the procedure significantly outperforms two other natural methods that are based on separate estimation of the individual correlation matrices. The procedure is also illustrated through an analysis of a breast cancer dataset, which provides evidence at the gene co-expression level that several genes, of which a subset has been previously verified, are associated with the breast cancer. Hypothesis testing on the differential correlation matrices is also considered. A test, which is particularly well suited for testing against sparse alternatives, is introduced. In addition, other related problems, including estimation of a single sparse correlation matrix, estimation of the differential covariance matrices, and estimation of the differential cross-correlation matrices, are also discussed.

  12. Conditional estimation of local pooled dispersion parameter in small-sample RNA-Seq data improves differential expression test.

    Science.gov (United States)

    Gim, Jungsoo; Won, Sungho; Park, Taesung

    2016-10-01

    High throughput sequencing technology in transcriptomics studies contribute to the understanding of gene regulation mechanism and its cellular function, but also increases a need for accurate statistical methods to assess quantitative differences between experiments. Many methods have been developed to account for the specifics of count data: non-normality, a dependence of the variance on the mean, and small sample size. Among them, the small number of samples in typical experiments is still a challenge. Here we present a method for differential analysis of count data, using conditional estimation of local pooled dispersion parameters. A comprehensive evaluation of our proposed method in the aspect of differential gene expression analysis using both simulated and real data sets shows that the proposed method is more powerful than other existing methods while controlling the false discovery rates. By introducing conditional estimation of local pooled dispersion parameters, we successfully overcome the limitation of small power and enable a powerful quantitative analysis focused on differential expression test with the small number of samples.

  13. New radiometric dates for the Prehistory of Northwestern Iberia: Valdavara Cave (Becerreá, Lugo

    Directory of Open Access Journals (Sweden)

    Vaquero Rodríguez, Manuel

    2009-06-01

    Full Text Available The goal of this paper is to make known the first results of the excavations in Valdavara Cave (Becerreá, Lugo, paying special attention to the radiometric dating that places this cave among the few Galician sites with Upper Palaeolithic dates. During the excavation carried out in 2007, two archaeological locations were documented in the same karstic system (Valdavara 1 and Valdavara 2. The test pit initiated in Valdavara 1 allowed us to identify so far two stratigraphic units: an upper unit corresponding to Recent Prehistory and a lower unit (level 4 that yielded the Upper Palaeolithic dates. An assemblage of human remains from the Bronze Age was found in Valdavara 2.

    El objetivo de este artículo es dar a conocer los primeros resultados de las excavaciones en la cueva de Valdavara (Becerreá, Lugo, prestando especial atención a las dataciones radiométricas que la sitúan entre los pocos yacimientos gallegos que han arrojado fechas correspondientes al Paleolítico Superior. La excavación realizada en el año 2007 permitió documentar dos localizaciones arqueológicas en el marco del mismo sistema cárstico (Valdavara 1 y Valdavara 2. El sondeo iniciado en Valdavara 1 ha permitido identificar hasta el momento dos conjuntos estratigráficos: un conjunto superior correspondiente a la Prehistoria reciente y un conjunto inferior (nivel 4 en el que se han obtenido las fechas del Paleolítico Superior final. En Valdavara 2 se encontró un conjunto de restos humanos de la Edad del Bronce.

  14. A Numerical Method for Partial Differential Algebraic Equations Based on Differential Transform Method

    Directory of Open Access Journals (Sweden)

    Murat Osmanoglu

    2013-01-01

    Full Text Available We have considered linear partial differential algebraic equations (LPDAEs of the form , which has at least one singular matrix of . We have first introduced a uniform differential time index and a differential space index. The initial conditions and boundary conditions of the given system cannot be prescribed for all components of the solution vector here. To overcome this, we introduced these indexes. Furthermore, differential transform method has been given to solve LPDAEs. We have applied this method to a test problem, and numerical solution of the problem has been compared with analytical solution.

  15. A radiometric model of an earth radiation budget radiometer optical system with diffuse-specular surfaces

    Science.gov (United States)

    Luther, M. R.

    1981-01-01

    The Earth Radiation Budget Experiment (ERBE) is to fly on NASA's Earth Radiation Budget Satellite (ERBS) and on NOAA F and NOAA G. Large spatial scale earth energy budget data will be derived primarily from measurements made by the ERBE nonscanning instrument (ERBE-NS). A description is given of a mathematical model capable of simulating the radiometric response of any of the ERBE-NS earth viewing channels. The model uses a Monte Carlo method to accurately account for directional distributions of emission and reflection from optical surfaces which are neither strictly diffuse nor strictly specular. The model computes radiation exchange factors among optical system components, and determines the distribution in the optical system of energy from an outside source. Attention is also given to an approach for implementing the model and results obtained from the implementation.

  16. Radiometric surveying for the assessment of radiation dose and radon specific exhalation in underground environment

    Science.gov (United States)

    Bochiolo, M.; Verdoya, M.; Chiozzi, P.; Pasquale, V.

    2012-08-01

    We performed a radiometric survey for evaluating the natural radioactivity and the related potential hazard level both outdoor and indoor a mine tunnel. The mine is located in a zone of uranium enrichment in the Western Alps (Italy). At first, a γ-ray spectrometry survey of the area surrounding the mine was carried out to define the extent of the ore deposit. Then, spectrometric measurements were performed in the tunnel and rock samples were collected for laboratory analyses. The results point to significant heterogeneity in uranium concentration and consequently in the absorbed dose rate spatial distribution. Spectrometric results in situ and in the laboratory, together with radon air concentration measurements, were used to infer the radon specific exhalation and flow from the mine rocks. The specific exhalation is positively related to the activity concentration of uranium.

  17. Benchmark test of MORSE-DD code using double-differential form cross sections

    International Nuclear Information System (INIS)

    Nakagawa, Masayuki; Mori, Takamasa; Ishiguro, Yukio

    1985-02-01

    The multi-group double-differential form cross sections (DDX) and the three dimensional Monte Carlo code MORSE-DD devised to utilize the DDX, which were developed for the fusion neutronics analysis, have been validated through many benchmark tests. All the problems tested have a 14 MeV neutron source. To compare the calculated results with the measured values, the following experiments were adopted as the benchmark problems; leakage neutron spectra from spheres composed of nine kinds of materials measured at LLNL, neutron angular spectra from the Li 2 O slab measured at FNS in JAERI, tritium production rate (TPR) in the graphite-reflected Li 2 O sphere measured at FNS and the TPR in the metallic Li sphere measured at KfK. In addition in order to test an accuracy of the calculation method in detail, spectra of neutrons scattered from a small sample and various reaction rates in a Li 2 O cylinder were compared between the present method and the continuous energy Monte Carlo method. The nuclear data files used are mainly ENDF/B4 and partly JENDL-3PR1. The tests were carried out through a comparison with the measured values and also with the results obtained from the conventional Legendre expansion method and the continuous energy Monte Carlo method. It is found that the results by the present method are more accurate than those by the conventional one and agree well with those by the continuous energy Monte Carlo calculations. Discrepancies due to the nuclear data are also discussed. (author)

  18. Clinical Utility of Short Social Cognitive Tests in Early Differentiation of Behavioral Variant Frontotemporal Dementia from Alzheimer’s Disease

    DEFF Research Database (Denmark)

    Buhl, Christian; Stokholm, Jette; Gade, Anders

    2013-01-01

    Traditional cognitive tests used in clinical practice may not be sensitive enough for the early differentiation of behavioral variant frontotemporal dementia (bvFTD) from Alzheimer's disease (AD). A growing body of literature has shown that deficits in various aspects of social cognition can be f...

  19. Helicopter-borne magnetic, electromagnetic and radiometric geophysical survey at Vanna, Karlsoey

    International Nuclear Information System (INIS)

    Rodionov, Alexei; Ofstad, Frode

    2012-01-01

    NGU conducted an airborne geophysical survey in Vanna area in June 2011 as a part of MINN project. This report describes and documents the acquisition, processing and visualization of recorded datasets. The geophysical survey results reported herein are 1336 line km. The modified Geotech Ltd. Hummingbird frequency domain system supplemented by optically pumped cesium magnetometer and 1024 channels RSX-5 spectrometer was used for data acquisition. The survey was flown with 200 m line spacing, line direction of 27 degrees NW and average speed 106 km/h. The average terrain clearance of the bird was 59 m. Collected data were processed in NGU using Geosoft Oasis Montaj software. Raw total magnetic field data were corrected for diurnal variation and levelled using standard micro levelling algorithm. EM data were filtered and levelled using both -automated and manual levelling procedure. Apparent resistivity was calculated from in-phase and quadrature data for four frequencies separately using a homogeneous half space model. Apparent resistivity dataset was filtered and levelled. Radiometric data were processed using standard procedures recommended by International Atomic Energy Association. All data were gridded with the cell size of 50 m and presented as a shaded relief maps at the scale of 1:50 000. (Author)

  20. Helicopter-borne magnetic, electromagnetic and radiometric geophysical survey at Vanna, Karlsoey

    Energy Technology Data Exchange (ETDEWEB)

    Rodionov, Alexei; Ofstad, Frode

    2012-07-01

    NGU conducted an airborne geophysical survey in Vanna area in June 2011 as a part of MINN project. This report describes and documents the acquisition, processing and visualization of recorded datasets. The geophysical survey results reported herein are 1336 line km. The modified Geotech Ltd. Hummingbird frequency domain system supplemented by optically pumped cesium magnetometer and 1024 channels RSX-5 spectrometer was used for data acquisition. The survey was flown with 200 m line spacing, line direction of 27 degrees NW and average speed 106 km/h. The average terrain clearance of the bird was 59 m. Collected data were processed in NGU using Geosoft Oasis Montaj software. Raw total magnetic field data were corrected for diurnal variation and levelled using standard micro levelling algorithm. EM data were filtered and levelled using both -automated and manual levelling procedure. Apparent resistivity was calculated from in-phase and quadrature data for four frequencies separately using a homogeneous half space model. Apparent resistivity dataset was filtered and levelled. Radiometric data were processed using standard procedures recommended by International Atomic Energy Association. All data were gridded with the cell size of 50 m and presented as a shaded relief maps at the scale of 1:50 000. (Author)

  1. Simultaneous Retrieval of Aerosol and Surface Optical Properties from Combined Airborne- and Ground-Based Direct and Diffuse Radiometric Measurements

    Science.gov (United States)

    Gatebe, C. K.; Dubovik, O.; King, M. D.; Sinyuk, A.

    2010-01-01

    This paper presents a new method for simultaneously retrieving aerosol and surface reflectance properties from combined airborne and ground-based direct and diffuse radiometric measurements. The method is based on the standard Aerosol Robotic Network (AERONET) method for retrieving aerosol size distribution, complex index of refraction, and single scattering albedo, but modified to retrieve aerosol properties in two layers, below and above the aircraft, and parameters on surface optical properties from combined datasets (Cloud Absorption Radiometer (CAR) and AERONET data). A key advantage of this method is the inversion of all available spectral and angular data at the same time, while accounting for the influence of noise in the inversion procedure using statistical optimization. The wide spectral (0.34-2.30 m) and angular range (180 ) of the CAR instrument, combined with observations from an AERONET sunphotometer, provide sufficient measurement constraints for characterizing aerosol and surface properties with minimal assumptions. The robustness of the method was tested on observations made during four different field campaigns: (a) the Southern African Regional Science Initiative 2000 over Mongu, Zambia, (b) the Intercontinental Transport Experiment-Phase B over Mexico City, Mexico (c) Cloud and Land Surface Interaction Campaign over the Atmospheric Radiation Measurement (ARM) Central Facility, Oklahoma, USA, and (d) the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) over Elson Lagoon in Barrow, Alaska, USA. The four areas are dominated by different surface characteristics and aerosol types, and therefore provide good test cases for the new inversion method.

  2. Lack of requirement for blind subcultures of BACTEC blood culture media

    International Nuclear Information System (INIS)

    McLaughlin, J.C.; Evers, J.L.; Officer, J.L.

    1981-01-01

    To determine the need for blind subculturing of BACTEC (Johnston Laboratories, Cockeysville, Md.) blood culture media, we compared results of radiometric readings, visual inspection, and blind subculturing for nearly 7,500 blood specimens. Visual inspection and radiometric testing were performed on day 1 through 7, and blind subcultures were made on day 3. In the first phase of the study, 402 of 3,896 aerobic bottles were positive by radiometric testing (growth index, greater than 25), visual inspection, or subculturing. Only six bottles were radiometrically negative but subculture positive on day 3. The second phase of the study was designed to determine if aerobic bottles eventually became radiometrically positive in those cases in which they were radiometrically negative but subculture positive on day 3. Two bottles were subculture positive but never gave a growth index of greater than or equal to 25 by day 7. One yielded Staphylococcus epidermidis, and one yielded viridans, Streptococcus sp. A total of 35 anaerobic organisms were isolated from 3,896 blood specimens. All of these anaerobes were detected by both radiometric testing and subculturing. We examined a total of 14,972 blood culture bottles. Twenty-nine bottles considered negative by visual inspection or radiometric readings were found to be positive by subculturing. Fifteen of these were shown, by chart review, to contain contaminants. Organisms in the other negative bottles would not have gone undetected because companion bottles from the same patients were radiometrically or visually positive. We concluded that it is necessary to perform blind subcultures of BACTEC 7B and 8B blood culture bottles

  3. A geological-radiometric uranium survey in the Tlaxiaco area of the State of Oaxaca

    International Nuclear Information System (INIS)

    Guillen R, O.E.

    1981-01-01

    Explorations were effected in the northwestern part of the State of Oaxaca neighbouring the city of Tlaxiaco and lying within the Oaxaca-Mixteca province. The survey comprised a regional area of 642.2.K, in which abnormalities auspicious to the presence of mineral uranium had previously been found. The area of interest, initially limited to a strip 10 kilometers long by 1/2 kilometers wide, showed evidence, however, of an even greater extension. Among the lithological units found of predominate interest were clastic, sedimentary rocks, mezozoic carbonate rocks, and extrusive and intrusive igneous rocks. From the high radiometric values obtained, the extrusive pyroclastic rocks showed more favourable signs of the presence of uranium ore and were considered of chief uranium significance in the area. Minerological, structural and lithological detectors (guides) have been set up in the area for an extensive location of abnormalities. The work based on regionally conducted geological and radiological surveys followed by detailed area of interest studies. (author)

  4. Determining water use of sorghum from two-source energy balance and radiometric temperatures

    Directory of Open Access Journals (Sweden)

    J. M. Sánchez

    2011-10-01

    Full Text Available Estimates of surface actual evapotranspiration (ET can assist in predicting crop water requirements. An alternative to the traditional crop-coefficient methods are the energy balance models. The objective of this research was to show how surface temperature observations can be used, together with a two-source energy balance model, to determine crop water use throughout the different phenological stages of a crop grown. Radiometric temperatures were collected in a sorghum (Sorghum bicolor field as part of an experimental campaign carried out in Barrax, Spain, during the 2010 summer growing season. Performance of the Simplified Two-Source Energy Balance (STSEB model was evaluated by comparison of estimated ET with values measured on a weighing lysimeter. Errors of ±0.14 mm h−1 and ±1.0 mm d−1 were obtained at hourly and daily scales, respectively. Total accumulated crop water use during the campaign was underestimated by 5%. It is then shown that thermal radiometry can provide precise crop water necessities and is a promising tool for irrigation management.

  5. Radiometric analysis of raw materials and end products in the Turkish ceramics industry

    Science.gov (United States)

    Turhan, Ş.; Arıkan, İ. H.; Demirel, H.; Güngör, N.

    2011-05-01

    This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest that the use of ceramic end product samples examined in the construction of dwellings, workplaces and industrial buildings in Turkey is unlikely to give rise to any significant radiation exposure to the occupants.

  6. Radiometric analysis of raw materials and end products in the Turkish ceramics industry

    International Nuclear Information System (INIS)

    Turhan, S.; Arikan, I.H.; Demirel, H.; Guengoer, N.

    2011-01-01

    This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest that the use of ceramic end product samples examined in the construction of dwellings, workplaces and industrial buildings in Turkey is unlikely to give rise to any significant radiation exposure to the occupants.

  7. Muscle Weakness in the Empty and Full Can Tests Cannot Differentiate Rotator Cuff Tear from Cervical Spondylotic Amyotrophy: Pain Provocation is a Useful Finding.

    Science.gov (United States)

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito

    2017-01-01

    Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.

  8. Effect of MODIS Terra Radiometric Calibration Improvements on Collection 6 Deep Blue Aerosol Products: Validation and Terra/Aqua Consistency

    Science.gov (United States)

    Sayer, A. M.; Hsu, N. C.; Bettenhausen, C.; Jeong, M.-J.; Meister, G.

    2015-01-01

    The Deep Blue (DB) algorithm's primary data product is midvisible aerosol optical depth (AOD). DB applied to Moderate Resolution Imaging Spectroradiometer (MODIS) measurements provides a data record since early 2000 for MODIS Terra and mid-2002 for MODIS Aqua. In the previous data version (Collection 5, C5), DB production from Terra was halted in 2007 due to sensor degradation; the new Collection 6 (C6) has both improved science algorithms and sensor radiometric calibration. This includes additional calibration corrections developed by the Ocean Biology Processing Group to address MODIS Terra's gain, polarization sensitivity, and detector response versus scan angle, meaning DB can now be applied to the whole Terra record. Through validation with Aerosol Robotic Network (AERONET) data, it is shown that the C6 DB Terra AOD quality is stable throughout the mission to date. Compared to the C5 calibration, in recent years the RMS error compared to AERONET is smaller by approximately 0.04 over bright (e.g., desert) and approximately 0.01-0.02 over darker (e.g., vegetated) land surfaces, and the fraction of points in agreement with AERONET within expected retrieval uncertainty higher by approximately 10% and approximately 5%, respectively. Comparisons to the Aqua C6 time series reveal a high level of correspondence between the two MODIS DB data records, with a small positive (Terra-Aqua) average AOD offset <0.01. The analysis demonstrates both the efficacy of the new radiometric calibration efforts and that the C6 MODIS Terra DB AOD data remain stable (to better than 0.01 AOD) throughout the mission to date, suitable for quantitative scientific analyses.

  9. Multivariate analysis of microarray data: differential expression and differential connection.

    Science.gov (United States)

    Kiiveri, Harri T

    2011-02-01

    Typical analysis of microarray data ignores the correlation between gene expression values. In this paper we present a model for microarray data which specifically allows for correlation between genes. As a result we combine gene network ideas with linear models and differential expression. We use sparse inverse covariance matrices and their associated graphical representation to capture the notion of gene networks. An important issue in using these models is the identification of the pattern of zeroes in the inverse covariance matrix. The limitations of existing methods for doing this are discussed and we provide a workable solution for determining the zero pattern. We then consider a method for estimating the parameters in the inverse covariance matrix which is suitable for very high dimensional matrices. We also show how to construct multivariate tests of hypotheses. These overall multivariate tests can be broken down into two components, the first one being similar to tests for differential expression and the second involving the connections between genes. The methods in this paper enable the extraction of a wealth of information concerning the relationships between genes which can be conveniently represented in graphical form. Differentially expressed genes can be placed in the context of the gene network and places in the gene network where unusual or interesting patterns have emerged can be identified, leading to the formulation of hypotheses for future experimentation.

  10. Glacier Remote Sensing Using Sentinel-2. Part I: Radiometric and Geometric Performance, and Application to Ice Velocity

    Directory of Open Access Journals (Sweden)

    Andreas Kääb

    2016-07-01

    Full Text Available With its temporal resolution of 10 days (five days with two satellites, and significantly more at high latitudes, its swath width of 290 km, and its 10 m and 20 m spatial resolution bands from the visible to the shortwave infrared, the European Sentinel-2 satellites have significant potential for glacier remote sensing, in particular mapping of glacier outlines and facies, and velocity measurements. Testing Level 1C commissioning and ramp-up phase data for initial sensor quality experiences, we find a high radiometric performance, but with slight striping effects under certain conditions. Through co-registration of repeat Sentinal-2 data we also find lateral offset patterns and noise on the order of a few metres. Neither of these issues will complicate most typical glaciological applications. Absolute geo-location of the data investigated was on the order of one pixel at the time of writing. The most severe geometric problem stems from vertical errors of the DEM used for ortho-rectifying Sentinel-2 data. These errors propagate into locally varying lateral offsets in the images, up to several pixels with respect to other georeferenced data, or between Sentinel-2 data from different orbits. Finally, we characterize the potential and limitations of tracking glacier flow from repeat Sentinel-2 data using a set of typical glaciers in different environments: Aletsch Glacier, Swiss Alps; Fox Glacier, New Zealand; Jakobshavn Isbree, Greenland; Antarctic Peninsula at the Larsen C ice shelf.

  11. Change of direction ability test differentiates higher level and lower level soccer referees

    Science.gov (United States)

    Los, Arcos A; Grande, I; Casajús, JA

    2016-01-01

    This report examines the agility and level of acceleration capacity of Spanish soccer referees and investigates the possible differences between field referees of different categories. The speed test consisted of 3 maximum acceleration stretches of 15 metres. The change of direction ability (CODA) test used in this study was a modification of the Modified Agility Test (MAT). The study included a sample of 41 Spanish soccer field referees from the Navarre Committee of Soccer Referees divided into two groups: i) the higher level group (G1, n = 20): 2ndA, 2ndB and 3rd division referees from the Spanish National Soccer League (28.43 ± 1.39 years); and ii) the lower level group (G2, n = 21): Navarre Provincial League soccer referees (29.54 ± 1.87 years). Significant differences were found with respect to the CODA between G1 (5.72 ± 0.13 s) and G2 (6.06 ± 0.30 s), while no differences were encountered between groups in acceleration ability. No significant correlations were obtained in G1 between agility and the capacity to accelerate. Significant correlations were found between sprint and agility times in the G2 and in the total group. The results of this study showed that agility can be used as a discriminating factor for differentiating between national and regional field referees; however, no observable differences were found over the 5 and 15 m sprint tests. PMID:27274111

  12. Radiometric studies on the oxidation of (I-14C) fatty acids by drug-susceptible and drug-resistant mycobacteria

    International Nuclear Information System (INIS)

    Camargo, E.E.; Kopajtic, T.M.; Hopkins, G.K.; Cannon, N.P.; Wagner Junior, H.N.

    1987-01-01

    A radiometric assay system has been used to study oxidation patterns of (l - 14 C) fatty acids by drug-susceptible and drug-resistant organisms of the genus Mycobacterium (M. tuberculosis - H 37 Rv and Erdman, M. bovis, M. avium, M. intracellulare, M.Kansasii and M. chelonei). The organisms were inoculated in sterile reaction vials containing liquid 7H9 medium, 10% ADC enrichment and 1.0 uli of one of the (l- 14 C) fatty acids (butyric, hexanoic, octanoic, decanoic, lauric, myristic, palmitic, stearic, oleic, linoleic, linolenic). Vials were incubated at 37 0 C and the 14 CO 2 envolved was measured daily for 3 days with a Bactec R-301 instrument. (M.A.C.) [pt

  13. Wide Band and Wide Azimuth Beam Effect on High-resolution Synthetic Aperture Radar Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Hong Jun

    2015-06-01

    Full Text Available Passive corner reflectors and active transponders are often used as man-made reference targets in Synthetic Aperture Radar (SAR radiometric calibration, With the emergence of new radar systems and the increasing demand for greater accuracy, wide-band and wide-beam radars challenge the hypothesis that the Radar Cross Section (RCS of reference targets is constant. In this study, the FEKO electromagnetic simulation software is used to obtain the change curve of the target RCS as a function of frequency and aspect angle while incorporating high-resolution point-target SAR simulation, and quantitatively analyzing the effect of the modulation effect on SAR images. The simulation results suggest that the abovementioned factors affect the SAR calibration by more than 0.2 dB within a fractional bandwidth greater than 10% or azimuth beam width of more than 20°, which must be corrected in the data processing.

  14. Differentiation of subdural effusions

    International Nuclear Information System (INIS)

    Wetterling, T.; Rama, B.

    1989-01-01

    Although X-ray computerized tomography facilitates the diagnosis of intracranial disorders, differentiation of the lesions like extracerebral effusions is often unsatisfactory. Epidural and acute subdural haematoma shown as hyperdensity in CT requires an emergency neurosurgical operation, so that differentiation of these hyperdense effusions may not be required. But the discrimination of the effusions shown as hypodensity in CT (chronic subdural haematoma, subdural hygroma, subdural empyema as well as arachnoid cysts) is urgent because of the different treatment of these effusions. The clinical differentiation is hampered by unspecific neurologic symptoms and the lack of adequate laboratory tests. Some aspects facilitating the diagnostic decision are presented. Recent magnetic resonance (MR) studies promise further progress in differentiating between subdural effusions. (orig.) [de

  15. CANONICAL BACKWARD DIFFERENTIATION SCHEMES FOR ...

    African Journals Online (AJOL)

    This paper describes a new nonlinear backward differentiation schemes for the numerical solution of nonlinear initial value problems of first order ordinary differential equations. The schemes are based on rational interpolation obtained from canonical polynomials. They are A-stable. The test problems show that they give ...

  16. Differential diagnosis of degenerative dementias using basic neuropsychological tests: multivariable logistic regression analysis of 301 patients.

    Science.gov (United States)

    Jiménez-Huete, Adolfo; Riva, Elena; Toledano, Rafael; Campo, Pablo; Esteban, Jesús; Barrio, Antonio Del; Franch, Oriol

    2014-12-01

    The validity of neuropsychological tests for the differential diagnosis of degenerative dementias may depend on the clinical context. We constructed a series of logistic models taking into account this factor. We retrospectively analyzed the demographic and neuropsychological data of 301 patients with probable Alzheimer's disease (AD), frontotemporal degeneration (FTLD), or dementia with Lewy bodies (DLB). Nine models were constructed taking into account the diagnostic question (eg, AD vs DLB) and subpopulation (incident vs prevalent). The AD versus DLB model for all patients, including memory recovery and phonological fluency, was highly accurate (area under the curve = 0.919, sensitivity = 90%, and specificity = 80%). The results were comparable in incident and prevalent cases. The FTLD versus AD and DLB versus FTLD models were both inaccurate. The models constructed from basic neuropsychological variables allowed an accurate differential diagnosis of AD versus DLB but not of FTLD versus AD or DLB. © The Author(s) 2014.

  17. Radiometric dating and quantitative analysis of elements in depth profiles of sediments by means of nuclear physical as well as X-ray fluorescence and atomic emission spectroscopic methods

    International Nuclear Information System (INIS)

    Schoenburg, M.

    1987-01-01

    The measurement of heavy metal concentration in sediments is of great importance for the assessment of water quality. If dating of the different layers of sediment cores is possible, informations about the history of pollution can be inferred. This paper describes the development and practical test of a procedure suitable for the investigation of sediment cores. Both the element analysis and the dating are based on physical methods. For element concentration determination inductively coupled plasma atomic emission spectrometry (ICP), total-reflection X-ray fluorescence analysis (TXRF) and neutron activation analysis (NAA) are used. The techniques are described and compared. For dating radiometric measurements of 210 Pb and 137 Cs are carried out with a coaxial well-type germanium γ-ray detector in a special low-level arrangement. Results of the systematic investigations are presented and a few individual depth profiles are discussed. (orig.) With 34 figs., 20 tabs [de

  18. Differential current measurement in the BNL energy recovery linac test facility

    International Nuclear Information System (INIS)

    Cameron, Peter

    2006-01-01

    An energy recovery linac (ERL) test facility is presently under construction at BNL [V.N. Litvinenko, et al., High current energy recovery linac at BNL, PAC, 2005; I. Ben-Zvi, et al., Extremely high current, high brightness energy recovery linac, PAC, 2005]. The goal of this test facility is to demonstrate CW operation with an average beam current greater than 100mA, and with greater than 99.95% efficiency of current recovery. This facility will serve as a test bed for the novel high current CW photo-cathode [A. Burrill, et al., Multi-alkali photocathode development at BNL, PAC, 2005; A. Murray, et al., State-of-the-art electron guns and injector designs for energy recovery linacs, PAC, 2005], the superconducting RF cavity with HOM dampers [R. Calaga, et al., High current superconducting cavities at RHIC, EPAC, 2004; R. Calaga, et al., in: Proceedings of the 11th workshop on RF superconductivity, Lubeck, Germany, 2003], and the lattice [D. Kayran, V. Litvinenko, Novel method of emittance preservation in ERL merging system in presence of strong space charge forces, PAC, 2005; D. Kayran, et al., Optics for high brightness and high current ERL project at BNL, PAC, 2005] and feedback systems needed to insure the specified beam parameters. It is an important stepping stone for electron cooling in RHIC [I. Ben-Zvi, et al., Electron cooling of RHIC, PAC, 2005], and essential to meet the luminosity specifications of RHICII [T. Hallman, et al., RHICII/eRHIC white paper, available at http://www.bnl.gov/henp/docs/NSAC_RHICII-eRHIC_2-15-03.pdf]. The expertise and experience gained in this effort might also extend forward into a 10-20GeV ERL for the electron-ion collider eRHIC [http://www.agsrhichome.bnl.gov/eRHIC/, Appendix A, The linac-ring option, 2005]. We report here on the use of a technique of differential current measurement to monitor the efficiency of current recovery in the test facility, and investigate the possibility of using such a monitor in the machine

  19. Development of radiometric methods for the determination of enzyme activities of iodothyronine deiodinases. Effect of the antidepressant fluoxetine on type 1, 2 and 3 deiodinase activities in the rat brain

    International Nuclear Information System (INIS)

    Pavelka, Stanislav

    2010-01-01

    The objectives of the present study were to establish valid assay conditions for measurement of the types 1, 2, and 3 (Dl, D2, and D3, respectively) iodothyronine deiodinases (IDs) activities, and to use the radiometric enzyme assays especially to follow the effects of antidepressant drug fluoxetine (Prozac) on the metabolism of thyroid hormones (TH) in the rat. In particular, the effects of subchronic administration of fluoxetine alone and in combination with 3,5,3'-triiodothyronine (T 3 ) on T 3 production and degradation in the CNS and peripheral tissues were investigated. The newly developed radiometric enzyme assays for IDs, based on the use of preferred 125 I-labeled iodothyronines as substrates, TLC separation of radioactive products from the unconsumed substrates, film-less autoradiography of radiochromatograms using storage phosphor screens, and quantification of the separated compounds with the BAS-5000 laser scanner, proved to be very sensitive and rapid and, at the same time, reliable and robust. (author)

  20. Pilot study of the application of Tellus airborne radiometric and soil geochemical data for radon mapping

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, J.D. [British Geological Survey, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom)], E-mail: jda@bgs.ac.uk; Miles, J.C.H.; Green, B.M.R. [Health Protection Agency (HPA) - Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Larmour, R. [Environment and Heritage Service, Department of the Environment, Belfast BT7 2JA (United Kingdom)

    2008-10-15

    The scope for using Tellus Project airborne gamma-ray spectrometer and soil geochemical data to predict the probability of houses in Northern Ireland having high indoor radon concentrations is evaluated, in a pilot study in the southeast of the province, by comparing these data statistically with in-house radon measurements. There is generally good agreement between radon maps modelled from the airborne radiometric and soil geochemical data using multivariate linear regression analysis and conventional radon maps which depend solely on geological and indoor radon data. The radon maps based on the Tellus Project data identify some additional areas where the radon risk appears to be relatively high compared with the conventional radon maps. One of the ways of validating radon maps modelled on the Tellus Project data will be to carry out additional indoor measurements in these areas.