WorldWideScience

Sample records for radiography theoretical analysis

  1. Radiography – How do students understand the concept of radiography?

    International Nuclear Information System (INIS)

    Lundgren, S.M.; Lundén, M.; Andersson, B.T.

    2015-01-01

    Background: Radiography as a concept has mainly been associated with the functional role of the radiographer. The concept has been studied from a theoretical point of view. However, there is a lack of a theoretical foundation and research on the actual substance of the term radiography used in education. It is therefore important to undertake an investigation in order to determine how students after three years education understand the subject of radiography. Aim: The aim of this study was to analyse how students in the Swedish radiographers' degree program understand the concept of radiography. Method: A concept analysis was made according to the hybrid model, which combines theoretical, fieldwork and analytical phases. A summative content analysis was used to identify the number and content of statements. The empirical data were collected from questionnaires answered by radiography students at four universities in Sweden. Findings: All radiography students' exemplified radiography with statements related to the practical level although some of them also identified radiography at an abstract level, as a subject within a discipline. The attribute ‘An interdisciplinary area of knowledge’ emerged, which is an attribute on the abstract level. The practical level was described by four attributes: Mastering Medical Imaging’, ‘To accomplish images for diagnosis and interventions’, ‘Creating a caring environment’ and ‘Enabling fruitful encounters’. Conclusion: The hybrid model used was a versatile model of concept development. The results of this study have increased the understanding of what characterizes the concept of radiography in a Swedish context. - Highlights: • This concept analysis of radiography was undertaken according to a hybrid model. • In radiography humanistic aspects are emphasized, a shift from the technological perspective. • The attributes demonstrate the essence and interdisciplinary nature of radiography. • This

  2. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  3. Preparation and realization of industrial radiography for the non destructive testing of welds in Nuclear Power Plants: A spatial cognition analysis

    International Nuclear Information System (INIS)

    Lafon, M.; Tonnoir, S.; Thibault, G.; Lafon, M.; Berthoz, A.

    2008-01-01

    Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)

  4. Theoretical and experimental comparison of proton and helium-beam radiography using silicon pixel detectors

    Science.gov (United States)

    Gehrke, T.; Amato, C.; Berke, S.; Martišíková, M.

    2018-02-01

    Ion-beam radiography (iRAD) could potentially improve the quality control of ion-beam therapy. The main advantage of iRAD is the possibility to directly measure the integrated stopping power. Until now there is no clinical implementation of iRAD. Topics of ongoing research include developing dedicated detection systems to achieve the desired spatial resolution (SR) and investigating different ion types as imaging radiation. This work focuses on the theoretical and experimental comparison of proton (pRAD) and helium-beam radiography (αRAD). The experimental comparison was performed with an in-house developed detection system consisting of silicon pixel detectors. This system enables the measurement of energy deposition of single ions, their tracking, and the identification of the ion type, which is important for αRAD due to secondary fragments. A 161 mm-thick PMMA phantom with an air gap of 1 mm placed at different depths was imaged with a 168 MeV u-1 proton/helium-ion beam at the Heidelberg ion-beam therapy center. The image quality in terms of SR and contrast-to-noise ratio (CNR) was evaluated. After validating MC simulations against experiments, pRAD and αRAD were compared to carbon-beam radiography (cRAD) in simulations. The theoretical prediction that the CNR of pRAD and αRAD is equal at similar imaging doses was experimentally confirmed. The measured SR of αRAD was 55% better compared to pRAD. The simulated cRads showed the expected improvement in SR and the decreased CNR at the same dose compared to the αRads, however only at dose levels exceeding typical doses of diagnostic x-ray projections. For clinically applicable dose levels, the cRads suffered from an insufficient number of carbon ions per pixel (220 μm  ×  220 μm). In conclusion, it was theoretically and experimentally shown that αRAD provides a better SR than pRAD without any disadvantages concerning the CNR. Using carbon ions instead of helium ions leads to a better SR at the

  5. Collaboration in radiography: A bibliometric analysis

    International Nuclear Information System (INIS)

    Snaith, Beverly

    2012-01-01

    Introduction: Increasing research activity is an aim of the radiography profession, but there is a lack of knowledge of how this can be achieved. Collaboration between clinical and academic centres as well as between individuals has increased productivity in other professions and has been suggested as a strategy for radiography. This bibliometric study maps the current contribution to the radiography evidence base through a single journal. Method: All articles published in Radiography from 1997 to 2011 were reviewed to identify collaboration trends together with article type and subject. Analysis also enabled comparison of research and publication patterns. Results: 706 articles were published by 1205 individual authors. 63.0% were written by UK based authors, although this varied over time. Over 80% of authors published only single article. Two thirds of articles were collaborative with an increase in clinical-academic co-authorship over the 15 years of the study. Although the majority of articles were diagnostic imaging based, the pattern mirrors the UK workforce profile. Clinicians, including clinical-academic co-authors, tend to write about clinical practice and roles, whereas academics write about a broader range of topics. Conclusions: There has been a growth in research and scholarship within the UK radiography journal and both clinical and academic radiographers are contributing to the evidence base through increased collaboration.

  6. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  7. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  8. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  9. Application of digital radiography in the analysis of cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T., E-mail: davi@lin.ufrj.br, E-mail: ccalza@lin.ufrj.br, E-mail: henrique@lin.ufrj.br, E-mail: joseilson@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear

    2013-07-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  10. Application of digital radiography in the analysis of cultural heritage

    International Nuclear Information System (INIS)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T.

    2013-01-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  11. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  12. Quantitative analysis of boron by neutron radiography

    International Nuclear Information System (INIS)

    Bayuelken, A.; Boeck, H.; Schachner, H.; Buchberger, T.

    1990-01-01

    The quantitative determination of boron in ores is a long process with chemical analysis techniques. As nuclear techniques like X-ray fluorescence and activation analysis are not applicable for boron, only the neutron radiography technique, using the high neutron absorption cross section of this element, can be applied for quantitative determinations. This paper describes preliminary tests and calibration experiments carried out at a 250 kW TRIGA reactor. (orig.) [de

  13. NDE of ceramic insulator blanks by radiography

    International Nuclear Information System (INIS)

    Sarvanan, S.; Venkatraman, B.; Jayakumar, T.; Baldev Raj

    1996-01-01

    The production of ceramic insulators in electrical industry involves a number of steps, one of which is the green blank. The defects such as voids and crack can be present in the extruded green blank. One of the best non-destructive evaluation (NDE) technique radiography. This paper deals with the development of methodology based on theoretical modeling for the examination of ceramics by high sensitivity radiography. (author)

  14. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  15. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  16. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  17. Theoretical foundations for reconstruction of the materials density by means of two-energy radiography

    International Nuclear Information System (INIS)

    Naydenov, S.V.; Ryzhikov, V.

    2003-01-01

    In non-destructive testing of building constructions, concrete structures, granular and powder materials, mixtures, alloys, etc. it is often very important to determine their mass and/or surface density. Density decreases or increases with respect to the standard values can substantially lower the quality of functional materials, as well strength of joints and constructions. In this paper, we have shown theoretically that the most complete solution of the inverse problem of quantitative reconstruction of the density profile can be given by means of two-energy radiography. A general expressions has been obtained for the surface density of an arbitrary material. Theoretically, the accuracy of the method is within several percent. An important point is that the approach proposed does not require any preliminary knowledge about physical or chemical composition of the tested object. This allows the use of the developed algorithm for universal testing of various construction objects in building and industry, including situations of prolonged service, when the chemical structure can get substantially changed. Among possible applications of the new method there are control testing in building and building industry, railway and vehicle transport, diagnostics of oil and gas pipes, hydrotechnical constructions (dams), etc

  18. Defective pixel map creation based on wavelet analysis in digital radiography detectors

    International Nuclear Information System (INIS)

    Park, Chun Joo; Lee, Hyoung Koo; Song, William Y.; Achterkirchen, Thorsten Graeve; Kim, Ho Kyung

    2011-01-01

    The application of digital radiography detectors has attracted increasing attention in both medicine and industry. Since the imaging detectors are fabricated by semiconductor manufacturing process over large areas, defective pixels in the detectors are unavoidable. Moreover, the radiation damage due to the routine use of the detectors progressively increases the density of defective pixels. In this study, we present a method of identifying defective pixels in digital radiography detectors based on wavelet analysis. Artifacts generated due to wavelet transformations have been prevented by an additional local threshold method. The proposed method was applied to a sample digital radiography and the result was promising. The proposed method uses a single pair of dark and white images and does not require them to be corrected in gain-and-offset properties. This method will be helpful for the reliable use of digital radiography detectors through the working lifetime.

  19. Analysis of causes of radiation overexposures for radiation workers in industrial radiography

    International Nuclear Information System (INIS)

    Mahajan, J.M.; Massand, O.P.

    2001-01-01

    About 5500 radiation workers are monitored from industrial institutions in our country out of which 3600 radiation workers are working in industrial radiography institutions. These workers have a higher potential of receiving overexposure (equivalent dose 3 10 mSv) due to their nature of work. This paper presents analysis of overexposures and their causes for radiation workers working in industrial radiography institutions during the last seven years. (author)

  20. Radiography and bone scintigraphy in multiple myeloma: a comparative analysis

    International Nuclear Information System (INIS)

    Ludwig, H.; Kumpan, W.; Sinzinger, H.

    1982-01-01

    The sensitivity of radionuclide imaging for detecting skeletal lesions was compared with that of radiography by evaluating 573 different anatomical sites in 41 patients with multiple myeloma. Radiography revealed a significantly greater number of myeloma-related bone lesions than did radionuclide imaging. Of the 179 myeloma-related bone lesions detected when both techniques were applied, 163 were seen by radiography and 82 by radionuclide imaging. Ninety-seven lesions were detected by radiography alone and 16 lesions seen by scintiscanning only, yielding a sensitivity of 91% for the former and of 46% for the latter technique. Radionuclide imaging proved superior to radiography only occasionally in the rib cage, and rarely in other anatomical sites. These findings suggest that radiography is the method of first choice in obtaining a skeletal survey in patients with multiple myeloma. In cases with continued pain, unexplained by standard radiography, the skeletal survey should be supplemented by tomography and radionuclide imaging. (author)

  1. Evaluation of the map accuracy thickness defects by computer analysis of the radiography images

    International Nuclear Information System (INIS)

    Wawszczak, J.; Wocial, A.

    2000-01-01

    Analysis of the sensitivity map radiography for the local profiles of the surface steel plate with artificial of the thickness defects were presented of the paper. Errors of these method estimation and they sources were presented also. Usefulness of this mapping radiography during field investigations for paper and film carriers were discussed and concluded. (author)

  2. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography

    International Nuclear Information System (INIS)

    Kirchner, J.; Stueckle, C.A.; Schilling, E.M.; Peters, J.

    2001-01-01

    To determine the diagnostic impact of daily bedside chest radiography in comparison with digital luminescence technique (DLR; storage phosphor radiography) and conventional film screen radiography, a prospective randomized study was completed in 210 mechanically ventilated patients with a total of 420 analysed radiographs. The patients were allocated to two groups: 150 patients underwent DLR, and 60 patients underwent conventional film screen radiography. Radiological analysis was performed consensually and therapeutic efficacy was assessed by the clinicians. There was no statistical significant difference between the frequency of abnormal findings seen on DLR and conventional film screen radiography. In total, 448 abnormal findings were present in 249 of 300 DLR and 97 of 120 conventional film screen radiographs. The most common findings were signs of overhydration (41 %), pleural effusion (31%), partial collapse of the lung (11%) and pneumothorax (2%). One hundred and twenty-three of 448 (27%) of these abnormal findings were thought to have a considerable impact on patient management. The high rate of abnormal findings with significant impact on patient management suggests that the use of daily bedside chest radiography may be reasonable. Copyright (2001) Blackwell Science Pty Ltd

  3. Human performance analysis of industrial radiography radiation exposure events

    International Nuclear Information System (INIS)

    Reece, W.J.; Hill, S.G.

    1995-01-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures

  4. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  5. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  6. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  7. Multidimensional analysis in industrial radiography

    International Nuclear Information System (INIS)

    Lavayssiere, B.; Georgel, B.

    1992-01-01

    EDF uses non-destructive testing by X or gamma-ray radiography for routine nozzle inspection in nuclear power plants. The images obtained are examined by radiographic specialists in order to detect, identify and quantify any defects, but the quality of the radiograms and the small size of the defects make their work extremely difficult. It is for these reasons that EDF developed ENTRAIGUES, a digital package for the processing and aid in interpretation of images generated by radiographical inspections, aimed at: -digitizing the radiographic films to be appraised, - facilitating analysis of the digitized radiograms. Defect orientation is estimated by 3D reconstruction of the component being inspected, based on a limited number of its projections. (authors). 11 figs., 6 refs

  8. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  9. Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis.

    Science.gov (United States)

    Alrajab, Saadah; Youssef, Asser M; Akkus, Nuri I; Caldito, Gloria

    2013-09-23

    Ultrasonography is being increasingly utilized in acute care settings with expanding applications. Pneumothorax evaluation by ultrasonography is a fast, safe, easy and inexpensive alternative to chest radiographs. In this review, we provide a comprehensive analysis of the current literature comparing ultrasonography and chest radiography for the diagnosis of pneumothorax. We searched English-language articles in MEDLINE, EMBASE and Cochrane Library dealing with both ultrasonography and chest radiography for diagnosis of pneumothorax. In eligible studies that met strict inclusion criteria, we conducted a meta-analysis to evaluate the diagnostic accuracy of pleural ultrasonography in comparison with chest radiography for the diagnosis of pneumothorax. We reviewed 601 articles and selected 25 original research articles for detailed review. Only 13 articles met all of our inclusion criteria and were included in the final analysis. One study used lung sliding sign alone, 12 studies used lung sliding and comet tail signs, and 6 studies searched for lung point in addition to the other two signs. Ultrasonography had a pooled sensitivity of 78.6% (95% CI, 68.1 to 98.1) and a specificity of 98.4% (95% CI, 97.3 to 99.5). Chest radiography had a pooled sensitivity of 39.8% (95% CI, 29.4 to 50.3) and a specificity of 99.3% (95% CI, 98.4 to 100). Our meta-regression and subgroup analyses indicate that consecutive sampling of patients compared to convenience sampling provided higher sensitivity results for both ultrasonography and chest radiography. Consecutive versus nonconsecutive sampling and trauma versus nontrauma settings were significant sources of heterogeneity. In addition, subgroup analysis showed significant variations related to operator and type of probe used. Our study indicates that ultrasonography is more accurate than chest radiography for detection of pneumothorax. The results support the previous investigations in this field, add new valuable information

  10. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  11. Research on non-destructive testing (NDT) aerospace igniter fuse with neutron radiography (NR)

    International Nuclear Information System (INIS)

    Mo Dawei; Liu Yisi; Cai Qingsheng; Chen Boxian

    1995-01-01

    The research works, facilities and results of NDT aerospace igniter fuse with neutron radiography at Tsinghua University swimming-pool reactor are introduced. The image quality (NR) of ASTM E545-85 I level was approached. The NR experimental research of the typical and possible defects was performed. The theoretical analysis was performed too. The feasibility of NDT aerospace igniter fuse with NR was proved experimentally

  12. Non-destructive analysis of rape plant pod by neutron radiography

    International Nuclear Information System (INIS)

    Makino-Nakanishi, Tomoko; Inanaga, Shinobu; Kobayashi, Hisao.

    1991-01-01

    Since the ripening process of the rape plant pod has not been studied well, non-destructive analysis of the pod has been carried out by neutron radiography. From the water distribution in the pod, the formation of pod parenchyma as well as vascular system were clearly observed. During the ripening process of the pod water content and weight of the seed were measured. It was found that at the early stage of the ripening process the water content of the seed became maximum and began to decrease, whereas the weight of each seed was gradually increased throughout the ripening process. Neutron radiography, which shows the water content of the pod, will give the clue to the decrease of the water content of the seed from the middle of the ripening process. (author)

  13. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  14. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  15. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  16. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  17. MTF analysis of the MURR real-time neutron radiography facility

    International Nuclear Information System (INIS)

    Lindsay, J.T.

    1982-01-01

    In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread function (LSF) to obtain the system MTF. A Gd foil was used for the knife-edge on several neutron converter screens and was imaged by a low-light level ISIT camera. The video signal was then digitized and presented to a PDP-11/05 microcomputer for the numerical calculations

  18. Cause analysis of missing diagnosis for vertebral fracture on lateral chest radiography

    International Nuclear Information System (INIS)

    Yu Wei; Yao Jinpeng; Lin Qiang; Mu Wenbin

    2010-01-01

    Objective: To analyze the cause of missing diagnosis for vertebral fracture on lateral chest radiography. Methods: Lateral chest radiographies of 1638 hospitalized patients (871 males and 767 females) were retrospectively reviewed for identifying vertebral fractures. Their ages ranged from 50 to 91 years with the mean of 63.5 years. Complains and application for chest radiography in all patients were not related to osteoporosis and vertebral fracture. Vertebral fracture and fracture severity were evaluated using Genant's semiquantitative visual method, taking approximately a 20%-25% vertebral height reduction as mild grade, 26%--40% as moderate grade and 41% or greater as severe grade. Evaluation results of the vertebral fracture, original X-ray reports, as well as medical records were compared for further analysis. Results: Eighty-four in 1638 patients showed vertebral fractures on the lateral chest radiographies. Of them, vertebral fractures were reported in 30 cases and 54 patients were not reported on their original X-ray reports. There were 63 vertebral fractures in 54 un-reported patients, most of which were single fracture (75% or 47/63). Grade I fracture accounted for 54% (34/63), Grade II fracture 33% (21/63), while 13% presented grade III fracture (8/63). In all 84 patients with vertebral fractures, only 5 cases (6%) underwent dual energy X-ray absorptiometry (DXA) measurement, 5 cases (6%) were recorded to have vertebral fractures on the medical papers, as well as 15 cases (18%) were prescribed drugs related to the osteoporosis when discharged from hospital. All drugs prescribed for the 15 patients were limited only to calcium. Conclusions: More attention should be paid to osteoporosis by doctors including radiologists. Vertebral fracture on lateral chest radiography should be completely diagnosed, which is helpful for both prevention and treatment. (authors)

  19. Digital radiography in space.

    Science.gov (United States)

    Hart, Rob; Campbell, Mark R

    2002-06-01

    With the permanent habitation of the International Space Station, the planning of longer duration exploration missions, and the possibility of space tourism, it is likely that digital radiography will be needed in the future to support medical care in space. Ultrasound is currently the medical imaging modality of choice for spaceflight. Digital radiography in space is limited because of prohibitive launch costs (in the region of $20,000/kg) that severely restrict the volume, weight, and power requirements of medical care hardware. Technological increases in radiography, a predicted ten-fold decrease in future launch costs, and an increasing clinical need for definitive medical care in space will drive efforts to expand the ability to provide medical care in space including diagnostic imaging. Normal physiological responses to microgravity, in conjunction with the high-risk environment of spaceflight, increase the risk of injury and could imply an extended recovery period for common injuries. The advantages of gravity on Earth, such as the stabilization of patients undergoing radiography and the drainage of fluids, which provide radiographic contrast, are unavailable in space. This creates significant difficulties in patient immobilization and radiographic positioning. Gravity-dependent radiological signs, such as lipohemarthrosis in knee and shoulder trauma, air or fluid levels in pneumoperitoneum, pleural effusion, or bowel obstruction, and the apical pleural edge in pneumothorax become unavailable. Impaired healing processes such as delayed callus formation following fracture will have implications on imaging, and recovery time lines are unknown. The confined nature of spacecraft and the economic impossibility of launching lead-based personal protective equipment present significant challenges to crew radiation safety. A modified, free-floating radiographic C-arm device equipped with a digital detector and utilizing teleradiology support is proposed as a

  20. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  1. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  2. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  3. SisRadiologia: a new software tool for analysis of radiological accidents and incidents in industrial radiography

    International Nuclear Information System (INIS)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da; Araujo, Rilton A.

    2013-01-01

    According to the International Atomic Energy Agency (IAEA), many efforts have been made by Member states, aiming a better control of radioactive sources. Accidents mostly happened in practices named as high radiological risk and classified by IAEA in categories 1 and 2, being highlighted those related to radiotherapy, large irradiators and industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography area, involving 37 workers, 110 members of the public and 12 fatalities. Records display 5 severe radiological accidents in industrial radiography activities in Brazil, in which 7 workers and 19 members of the public were involved. Such events led to hands and fingers radiodermatitis, but to no death occurrence. The purpose of this study is to present a computational program that allows the data acquisition and recording in the company, in such a way to ease a further detailed analysis of radiological event, besides providing the learning cornerstones aiming the avoidance of future occurrences. After one year of the 'Industrial SisRadiologia' computational program application - and mostly based upon the workshop about Analysis and Dose Calculation of Radiological Accidents in Industrial Radiography (Workshop sobre Analise e Calculo de dose de acidentes Radiologicos em Radiografia Industrial - IRD 2012), in which several Radiation Protection officers took part - it can be concluded that the computational program is a powerful tool to data acquisition, as well as, to accidents and incidents events recording and surveying in Industrial Radiography. The program proved to be efficient in the report elaboration to the Brazilian Regulatory Authority, and very useful in workers training to fix the lessons learned from radiological events.

  4. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  5. Fundamental of neutron radiography and the present of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Sekita, Junichiro

    1988-01-01

    Neutron radiography refers to the application of transmitted neutrons to analysis. In general, thermal neutron is used for neutron radiography. Thermal neutron is easily absorbed by light atoms, including hydrogen, boron and lithium, while it is not easily absorbed by such heavy atoms as tungsten, lead and uranium, permitting detection of impurities in heavy metals. Other neutrons than thermal neutron can also be applied. Cold neutron is produced from fast neutron using a moderator to reduce its energy down to below that of thermal neutron. Cold neutron is usefull for analysis of thick material. Epithermal neutron can induce resonance characteristic of each substance. With a relatively small reaction area, fast neutron permits observation of thick samples. Being electrically neutral, neutrons are difficult to detect by direct means. Thus a substance that releases charged particles is put in the path of neutrons for indirect measurement. X-ray film combined with converter screen for conversion of neutrons to charge particles is placed behind the sample. Photographing is carried out by a procedure similar to X-ray photography. Major institues and laboratories in Japan provided with neutron radiography facilities are listed. (Nogami, K.)

  6. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  7. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  8. Object position and image magnification in dental panoramic radiography: a theoretical analysis.

    Science.gov (United States)

    Devlin, H; Yuan, J

    2013-01-01

    The purpose of our study was to investigate how image magnification and distortion in dental panoramic radiography are influenced by object size and position for a small round object such as a ball bearing used for calibration. Two ball bearings (2.5 mm and 6 mm in diameter) were placed at approximately the same position between the teeth of a plastic skull and radiographed 21 times. The skull was replaced each time. Their images were measured by software using edge detection and ellipse-fitting algorithms. Using a standard definition of magnification, equations were derived to enable an object's magnification to be determined from its position and vice versa knowing the diameter and machine parameters. The average magnification of the 2.5 mm ball bearing was 1.292 (0.0445) horizontally and 1.257 (0.0067) vertically with a mean ratio of 1.028 (0.0322); standard deviations are in parentheses. The figures for the 6 mm ball bearing were 1.286 (0.0068), 1.255 (0.0018) and 1.025 (0.0061), respectively. Derived positions of each ball bearing from magnification were more consistent horizontally than vertically. There was less variation in either direction for the 6 mm ball bearing than the 2.5 mm one. Automatic measurement of image size resulted in less variation in vertical magnification values than horizontal. There are only certain positions in the focal trough that achieve zero distortion. Object location can be determined from its diameter, measured magnification and machine parameters. The 6 mm diameter ball bearing is preferable to the 2.5 mm one for more reliable magnification measurement and position determination.

  9. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  10. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis

    Science.gov (United States)

    Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.

    2017-08-01

    Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.

  11. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  12. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  13. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.

  14. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  15. Digital radiography: study of an alternative technique to conventional radiography

    International Nuclear Information System (INIS)

    Banchet, J.; Tisseur, D.; Thomas, A.

    2009-01-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  16. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  17. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  18. Basic principles of industrial radiography

    International Nuclear Information System (INIS)

    Bestbier, P.

    1983-01-01

    X-ray radiography and gamma radiography are used in industrial radiography. X-rays and gamma rays have the ability to penetrate materials and be absorbed by different densities. This characteristic makes them useful tools in industrial and medical radiography. The sources used for the generation of x-rays, gamma rays and radioisotopes are discussed. Films are one of the recording methods of x-radiography. The article also deals with advantages and disadvantages of radiography. Factors governing radiation exposure includes: the type of radiation source, material to be radiographed, distance, film, and the method for development. International specifications are also responsible for strict control over the standard of workmanship in industrial radiography

  19. In vitro synchrotron-based radiography of micro-gap formation at the implant–abutment interface of two-piece dental implants

    International Nuclear Information System (INIS)

    Rack, A.; Rack, T.; Stiller, M.; Riesemeier, H.; Zabler, S.; Nelson, K.

    2010-01-01

    Micro-radiography using hard X-ray synchrotron radiation is the first potential tool to allow an evaluation of the mechanical behavior of the dental implant–abutment complex during force application, thus enabling the enhancement of the design of dental implants which has been based on theoretical analysis to date. Micro-gap formation at the implant–abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites

  20. In vitro synchrotron-based radiography of micro-gap formation at the implant–abutment interface of two-piece dental implants

    Energy Technology Data Exchange (ETDEWEB)

    Rack, A., E-mail: arack@snafu.de [European Synchrotron Radiation Facility, Grenoble (France); Rack, T. [Charité, Department of Oral and Maxillofacial Surgery, Clinical Navigation and Robotics, Berlin (Germany); Stiller, M. [Charité, Department of Maxillofacial and Facial-Plastic Surgery, Division of Oral Medicine, Radiology and Surgery, Berlin (Germany); Riesemeier, H. [Bundesanstalt für Materialforschung und -prüfung, Division Structure Analysis, Polymer Analysis, Berlin (Germany); Zabler, S. [Technical University of Berlin, Institute for Materials Engineering (Germany); Nelson, K. [Charité, Department of Oral and Maxillofacial Surgery, Clinical Navigation and Robotics, Berlin (Germany)

    2010-03-01

    Micro-radiography using hard X-ray synchrotron radiation is the first potential tool to allow an evaluation of the mechanical behavior of the dental implant–abutment complex during force application, thus enabling the enhancement of the design of dental implants which has been based on theoretical analysis to date. Micro-gap formation at the implant–abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  1. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  2. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  3. Clinical analysis of 125I seed implants in worst-casts of the malignant tumors after radiography and chemotherapy

    International Nuclear Information System (INIS)

    Chen Zhijun; Tu Xinhua; Zhou Aiqing; Wang Xueqin

    2006-01-01

    Objective: To investigate the curative effect and side reaction after 125 I seed implanted among tissue were treated the malignant neoplasm by radiography and chemotherapy. Methods: Retrospective analysis the cancerous sufferer after the failure of radiography and chemotherapy, percutaneous puncture or intraoperative under gaze forward 125 I seed were implanted the bed of the tumour forever. Follow-up blood routine examination, symptom, sign, using USG or CT observe the change of the tumour and the distribution of the particles etc. Results: In 3 cases, treat 2 cases, tumour reduced obviously, symptoms improved obviously, the face of the ulcer cured, the particles did not shift, hemogram did not decline obviously. Conclusion: 125 I seed among the tissue implanted forever for the unsuccessful case after radiography and chemotherapy supply a new therapeutic methods. In the neat future curative effect is exactly, toxic reaction is small, which can remedy the deficiency of the treatment for radiography and chemotherapy. (authors)

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  6. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  7. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  9. Analysis of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants

    International Nuclear Information System (INIS)

    Sahuinco, Humberto Lazaro Choquepuma; Souza, Ricardo Pires de

    2006-01-01

    Objective: to determine agreement of three observers on analysis of linear measurements of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants. Material and Method: the samples of 17 patients were analyzed with computed tomography and panoramic radiography. Linear measurements obtained from both methods were made at the following anatomical points: left tuberosity, left canine pillar, incisive foramen, right canine pillar and right tuberosity. Kendall's W test was applied to assess the level of agreement. Results: measured W-values from the samples of the anatomical points mentioned above, analyzed with panoramic radiography and computed tomography, were: 0.75 and 0.901; 0.916 and 0.956; 0.843 and 0.964; 0.963 and 0.931; 0.95 and 0.89 respectively. Statistical analysis showed that there was no statistically significant difference. Conclusion: agreement occurred in the measurements of variables.That means that if the three observers were to select an implant to be placed in each of the anatomical regions studied, there would be a good chance whey would choose the same type. (author)

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  11. Clinical Evaluation of a Dual-Side Readout Technique Computed Radiography System in Chest Radiography of Premature Neonates

    International Nuclear Information System (INIS)

    Carlander, A.; Hansson, J.; Soederberg, J.; Steneryd, K.; Baath, M.

    2008-01-01

    Background: Recently, the dual-side readout technique has been introduced in computed radiography, leading to an increase in detective quantum efficiency (DQE) compared with the single-side readout technique. Purpose: To evaluate if the increase in DQE with the dual-side readout technique results in a higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Material and Methods: Twenty-four chest radiographs of premature neonates were collected from both a single-side readout technique system and a double-side readout technique system. The images were processed in the same image-processing station in order for the comparison to be only dependent on the difference in readout technique. Five radiologists rated the fulfillment of four image quality criteria, which were based on important anatomical landmarks. The given ratings were analyzed using visual grading characteristics (VGC) analysis. Results: The VGC analysis showed that the reproduction of the carina with the main bronchi and the thoracic vertebrae behind the heart was better with the dual-side readout technique, whereas no significant difference for the reproduction of the central vessels or the peripheral vessels could be observed. Conclusions: The results indicate that the higher DQE of the dual-side readout technique leads to higher clinical image quality in chest radiography of premature neonates at no increase in radiation dose. Keywords: Digital radiography; lung; observer performance; pediatrics; thorax

  12. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  13. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  14. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  15. Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography

    International Nuclear Information System (INIS)

    Grunert, J.H.; Borchert, B.; Farber, A.; Gmelin, E.

    1999-01-01

    Aims of the study: The purpose of this study was to investigate the efficacy of 4-fold magnification breast specimen radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography in evaluating the presence of absence of carcinoma at the surgical margins by detection of microcalcification. Results: In 50 specimen 2821 (1305 within 3 mm distance to the margins) microcalcifications were detected with the DIMA mammography technique compared to 1608 (446) microcalcifications with the conventional technique. This increased detection rate by DIMA-magnetification radiography was accompanied by a decreased specificity in comparison to the conventional magnification radiography (33,3% DIMA versus 83,3% conventional) regarding the evaluation of presence or absence of carcinoma at the surgical margins. Differentiating the microcalcifications into calcifications belonging to the suspicious cluster and those that are located outside the cluster led to an increase in specificity (83,3% DIMA versus 100% conventional). Conclusions: The efficacy of breast specimens radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification is not improved by 4-fold magnification radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography due to an increase in false-positive results. Analysis of the attachement of the microcalcifications to the cluster can improve the specificity. (orig.) [de

  16. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition); Surete radiologique en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-05-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in Horizontal-Ellipsis shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  17. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  18. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  19. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  20. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  1. Dose area product measurement for diagnostic reference levels and analysis of patient dose in dental radiography

    International Nuclear Information System (INIS)

    Han, S.; Lee, B.; Shin, G.; Choi, J.; Kim, J.; Park, C.; Park, H.; Lee, K.; Kim, Y.

    2008-01-01

    In this study, diagnostic reference levels (DRLs) were suggested and patient doses were analysed through the dose-area product value in dental radiography. In intraoral radiography, at three sites, i.e. molar, premolar and incisor on the maxilla and acquired third quartile values: 55.5, 46 and 36.5 mGy cm 2 , respectively, were measured. In panoramic, cephalo-metric and cone beam computed tomography, the values were 120.3, 146 and 3203 mGy cm 2 (16 x 18 cm), respectively. It has been shown that, in intraoral radiography, the patient dose changes proportionally to the value of mA s, but the change in extra-oral radiography in response to mA s could not be confirmed. The authors could confirm, however, the difference in dose according to the manufacturer in all dental radiography examinations, except for panoramic radiography. Depending on the size of hospital, there were some differences in patient dose in intraoral radiography, but no difference in patient dose in extra-oral radiography. (authors)

  2. Imaging characteristics in rotational panoramic radiography

    International Nuclear Information System (INIS)

    Sanderink, G.C.H.

    1987-01-01

    This study is concerned with imaging quality in rotational panoramic radiography. This imaging technique records an image of a curved layer within the object radiographed. The shape of this layer normally corresponds with the average form of the dental arch. In the centre of the layer a plane can be found which is depicted with a minimum of unsharpness. Unsharpness increases and the horizontal magnification changes as distance increases from that central plane. The image quality of the layer has been analyzed with the use of mathematical models to estimate the performance of the radiographic diagnostic system. Despite the application of these increasingly sophisticated models the question remains: will the results of the calculations based on these models adequately predict the diagnostic effectiveness of this type of imaging system? In this study a comparison is made between the theoretically determined quality of the system and the diagnostic quality using the observer as a measuring instrument. Experiments were carried out to measure the total unsharpness occurring in rotational panoramic radiography. 116 refs.; 114 figs.; 54 tabs

  3. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  4. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  5. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.

    Science.gov (United States)

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-12-01

    To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.

  6. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  7. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  8. Radiation dose distribution monitoring at neutron radiography facility area, Nuclear Energy Unit, Malaysia

    International Nuclear Information System (INIS)

    Abdul Razak Daud

    1995-01-01

    One experiment was carried out to get the distribution of radiation doses at the neutron radiography facilities, Nuclear Energy Unit, Malaysia. The analysis was done to evaluate the safety level of the area. The analysis was used in neutron radiography work

  9. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  10. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  11. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  12. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  13. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  14. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  15. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  16. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Mahmoud Yousefifard

    2016-01-01

    Full Text Available Introduction: The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. Methods: An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. Results: 12 studies were included in this meta-analysis (1554 subjects, 58.6% male. Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, p<0.001 and its pooled specificity was calculated to be 0.98 (95% CI: 0.92-1.0; I2= 88.65, p<0.001, while sensitivity and specificity of chest radiography were 0.51 (95% CI: 0.33-0.68; I2= 91.76, p<0.001 and 0.91 (95% CI: 0.68-0.98; I2= 92.86, p<0.001, respectively. Sensitivity of ultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Conclusion: Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  17. Radiogenic cancer induction associated with spinal radiography: a quantitative analysis

    International Nuclear Information System (INIS)

    Fickel, T.E.

    1988-01-01

    Computations of organ-specific radiation absorption by lung, breast, thyroid, active bone marrow and uterine tissues are used to rank sectional and full spine radiographic procedures according to their potentials for cancer induction. Assuming that the dose-effect relationship of radiation damage is linear and lacks a threshold effect, the prospective and retrospective carcinogenicities of commonly ordered spinal series are estimated. Cervical radiography is demonstrated to pose the least hazard to the patient, while full spine and lumbar (five views) procedures have the greatest. Organs most at risk as a result of spinal radiography are lung (thoracic and full spine), colon (lumbar and full spine), breast (thoracic and full spine), and prostate (full spine and lumbar)

  18. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  19. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  20. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  1. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  2. High speed motion neutron radiography of two-phase flow

    International Nuclear Information System (INIS)

    Robinson, A.H.; Wang, S.L.

    1983-01-01

    Current research in the area of two-phase flow utilizes a wide variety of sensing devices, but some limitations exist on the information which can be obtained. Neutron radiography is a feasible alternative to ''see'' the two-phase flow. A system to perform neutron radiographic analysis of dynamic events which occur on the order of several milliseconds has been developed at Oregon State University. Two different methods have been used to radiograph the simulated two-phase flow. These are pulsed, or ''flash'' radiography, and high speed movie neutron radiography. The pulsed method serves as a ''snap-shot'' with an exposure time ranging from 10 to 20 milliseconds. In high speed movie radiography, a scintillator is used to convert neutrons into light which is enhanced by an optical intensifier and then photographed by a high speed camera. Both types of radiography utilize the pulsing capability of the OSU TRIGA reactor. The principle difficulty with this type of neutron radiography is the fogging of the image due to the large amount of scattering in the water. This difficulty can be overcome by using thin regions for the two-phase flow or using heavy water instead of light water. The results obtained in this paper demonstrate the feasibility of using neutron radiography to obtain data in two-phase flow situations. Both movies and flash radiographs have been obtained of air bubbles in water and boiling from a heater element. The neutron radiographs of the boiling element show both nucleate boiling and film boiling. (Auth.)

  3. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  5. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  6. Structural analysis of jewelry from the Moche tomb of the `lady of Cao' by X-ray digital radiography

    Science.gov (United States)

    Azeredo, S. R.; Cesareo, R.; Franco, R.; Fernandez, A.; Bustamante, A.; Lopes, R. T.

    2018-04-01

    Nose ornaments from the tomb of the `Lady of Cao', a mummified woman representative of the Moche culture and dated to the third-or-fourth century AD, were analyzed by X-ray digital radiography. These spectacular gold and silver jewels are some of the most sophisticated metalworking ever produced in ancient America. The Mochecivilization flourished along the north coast of present-day Peru, between the Andes and the Pacific Ocean, approximately between 100 and 600 AD. The Moche were very sophisticated artisans and metal smiths, being considered the finest producers of jewels and artifacts of the region. A portable X-ray digital radiography (XDR) system consisting of a flat panel detector with high resolution image and a mini X-ray tube was used for the structural analysis of the Moche jewels aiming at inferring different joining methods of the silver-gold sheets. The radiographic analysis showed some differences in the joint of the silver-and-gold sheets. Presence of filler material and adhesive for joining the silver-and-gold sheets was visible as well as silver-gold junctions without filler material (or with a material invisible in radiography). Furthermore, the technique demonstrated the advantage of using a portable XDR micro system when the sample cannot be brought to the laboratory.

  7. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  8. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  9. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  10. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  11. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  12. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  13. Diagnostic Accuracy of Cone-beam Computed Tomography and Conventional Radiography on Apical Periodontitis: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Leonardi Dutra, Kamile; Haas, Letícia; Porporatti, André Luís; Flores-Mir, Carlos; Nascimento Santos, Juliana; Mezzomo, Luis André; Corrêa, Márcio; De Luca Canto, Graziela

    2016-03-01

    Endodontic diagnosis depends on accurate radiographic examination. Assessment of the location and extent of apical periodontitis (AP) can influence treatment planning and subsequent treatment outcomes. Therefore, this systematic review and meta-analysis assessed the diagnostic accuracy of conventional radiography and cone-beam computed tomographic (CBCT) imaging on the discrimination of AP from no lesion. Eight electronic databases with no language or time limitations were searched. Articles in which the primary objective was to evaluate the accuracy (sensitivity and specificity) of any type of radiographic technique to assess AP in humans were selected. The gold standard was the histologic examination for actual AP (in vivo) or in situ visualization of bone defects for induced artificial AP (in vitro). Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v.5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark) and MetaDisc v.1.4. software (Unit of Clinical Biostatistics Team of the Ramón y Cajal Hospital, Madrid, Spain). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Only 9 studies met the inclusion criteria and were subjected to a qualitative analysis. A meta-analysis was conducted on 6 of these articles. All of these articles studied artificial AP with induced bone defects. The accuracy values (area under the curve) were 0.96 for CBCT imaging, 0.73 for conventional periapical radiography, and 0.72 for digital periapical radiography. No evidence was found for panoramic radiography. Periapical radiographs (digital and conventional) reported good diagnostic accuracy on the discrimination of artificial AP from no lesions, whereas CBCT imaging showed excellent accuracy values. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  14. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  15. Accidents in industrial radiography in Brazil from 2005 to 2010

    International Nuclear Information System (INIS)

    Lopes, Ricardo Tadeu

    2011-01-01

    Analysis of accidents occurring in industrial radiography in Brazil from 2005 until 2010 led to the study of the main characteristics of the events, their risks and dangers. This study outlines the main doubts on the subject, through a simplified analysis of the contents of high dose reports sent to CNEN by the companies that provide services for industrial radiography and from examining the growing number of radioactive sources for industrial radiography in Brazil, over this period. We classified the recorded events, as incidents, accidents, negligence, sabotage, and others, and studied their main consequences. We concluded that from 76 accidents that occurred during that period - 25 were real accidents, 13 minor accidents and 22 were inadvertent incidents. We found that the rate of growth in the number of sources is much greater than the rate of growth of accidents, with a ratio of 7.57 between them. The continuation of this study over some years, will allow the construction of a pyramid of accidents like the one developed by the Insurance Company of North America, specifically for industrial radiography to forecast the number of incidents and accidents that lead to serious or fatal injury. (author)

  16. Diagnostic value of full-mouth radiography in cats

    International Nuclear Information System (INIS)

    Verstraete, F.J.M.; Kass, P.H.; Terpak, C.H.

    1998-01-01

    Objective-To determine the diagnostic value of full-mouth radiographyin cats.Sample Population-115 cats referred for dental treatment without a previous full-mouth radiographic series available. Procedure-In a prospective nested case-control analysis of multiple outcomes in a hospital cohort of cats referred for dental treatment, full-mouth radiography was done prior to oral examination and charting. After treatment, the clinical and radiographic findings were compared, with reference to presenting problems, main clinical findings, additional information obtained from radiography and unexpected radiographic findings. Importance of the radiographic findings in therapeutic decision making was assessed. Results-The main clinical findings were radiographically confirmed in all cats. Odontoclastic resorption lesions, missed on clinical examination, were diagnosed in 8.7% of cats. Analysis of selected presenting problems and main clinical findings yielded significantly increased odds ratios for a variety of other conditions, either expected or unexpected. Radiographs of teeth without clinical lesions yielded incidental or clinically important findings in 4.8 and 41.7% of cats, respectively, and were considered of no clinical value in 53.6%. Radiographs of teeth with clinical lesions merely confirmed the findings in 13.9% of cats, but yielded additional or clinically essential information in 53.9 and 32.2%, respectively. Clinical Relevance-The diagnostic yield of full-mouth radiography in new feline patients referred for dental treatment is high, and routine use of full-mouth radiography is justifiable

  17. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  18. Utilization and costs of lumbar and full spine radiography by Ontario chiropractors from 1994 to 2001.

    Science.gov (United States)

    Ammendolia, Carlo; Côté, Pierre; Hogg-Johnson, Sheilah; Bombardier, Claire

    2009-07-01

    In Ontario, chiropractors see one-third of patients who seek care for low back pain. Previous studies suggest that chiropractors have high utilization rates of lumbar and full spine radiography. There has been a proliferation of evidence-based guidelines recommending that plain film radiography be used only to assess high-risk patients with low back pain. Evidence for the use of full spine radiography, except for the evaluation of scoliosis is lacking. It is uncertain what impact the growing evidence against their use has had on radiography utilization by Ontario chiropractors. To describe the annual costs and use of lumbar and full spine plain film radiography among Ontario chiropractors between 1994 and 2001. Time-trend analysis of radiography utilization by Ontario chiropractors. Chiropractic claims data submitted to the Ontario Health Insurance Plan or the Workplace Safety & Insurance Board from 1994/1995 to 2000/2001. Change in the annual cost and proportion of claimants receiving lumbar and full spine radiography. Time-trend analysis of chiropractic claims submitted to the Ontario Health Insurance Plan (OHIP) or Workplace Safety & Insurance Board (WSIB) from 1994/1995 to 2000/2001 fiscal years. During the 7-year period, the proportion of OHIP claimants receiving lumbar spine radiography decreased from 4.54% to 3.25% and for full spine radiography from 3.87% to 3.04%. For WSIB claimants, lumbar spine radiography deceased from 6.49% to 3.30% of claimants and full spine radiography from 1.51% to 0.94%. OHIP payments for lumbar spine radiography decreased 12.7% to $562,944, whereas full spine radiography payments decreased 5.3% to $1,071,408. WSIB lumbar and full spine radiography payments decreased 44.2% and 34.3% to $31,202 and $11,713 respectively. Claims data from the two largest third-party payers of chiropractic services in Ontario, suggest that lumbar and full spine radiography, and their associated costs decreased steadily between 1994 and 2001.

  19. Evaluation of the effectiveness of digital radiography in emergency situations

    International Nuclear Information System (INIS)

    Pathi, R.; Langlois, S.

    2002-01-01

    The time differences between digital and conventional radiography for emergency patients were investigated, and clinician satisfaction with the two modalities was compared. Time-motion data was collected daily over 5 weeks for a digital group and a conventional X-ray group. For standardization purposes, only emergency patients requiring chest X-rays were selected for the study. Data were collected from 30 patients in each of the two groups in the time-motion study, and 31 out of 50 Emergency and Intensive Care clinicians responded to the questionnaire. Results were analysed by percentage, and χ 2 analysis was used where appropriate. The time for availability of images to requesting clinicians was 70% less for digital images compared to conventional radiography. The overall satisfaction between digital and conventional radiography was very similar, but most clinicians expressed an opinion that digital radiography offered significant image modification advantages. Copyright (2002) Blackwell Science Pty Ltd

  20. First experience with digital radiography

    International Nuclear Information System (INIS)

    Buchmann, F.

    1987-01-01

    The digital radiogram is explained, its advantages being the various possibilities of image processing, loss-free transmission, recording and storage capabilities, and in special cases, prompt availability of processed images. Digital subtraction angiography (DSA) and the high-resolution method of digital, luminescent radiography, which replaced the conventional film-foil radiography, are explained as the first developments for the introduction of digital radiography, which today already is an applicable technique. (orig./MG) [de

  1. Problems associated with digital luminescence radiography in the neonate and young infant. Problems with digital radiography.

    Science.gov (United States)

    Arthur, R J; Pease, J N

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted.

  2. Prospective study of irradiation and magnification on a pelvic imaging: EOS system versus conventional radiography

    International Nuclear Information System (INIS)

    Demoulin, Loic

    2015-01-01

    The pelvic x-ray is essential for the orthopedic practise. Recently, EOS system has been developed with technology to limit irradiation and theoretically not create magnification. The objective of this study was to evaluate the EOS system realizing a pelvic x-ray. All patients who underwent hip replacement between September 2014 and April 2015 have benefited pelvis radiograph with the 2 techniques, after surgery. The size of the head was measured with both techniques and compared to the established size. Irradiation of each technique was listed. A correlation study was carried out with the body mass index (BMI) of the patient. Irradiation was significantly greater with conventional radiography than with the EOS system: PDS of conventional radiography = 15.0 (10.5; 25.2) against the EOS system PDS = 8.2 (7.1; 9.7), p ≤0.0001. It was found a significant correlation between BMI and irradiation, particularly with conventional radiography. About expansion, the EOS system not create any except in 4 cases, unlike the conventional radiograph. The EOS system significantly decreases irradiation in all patients, compared to the conventional radiography, and it do not create magnification when realizing a pelvic x-ray, even in overweight patients [fr

  3. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  4. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  5. Proton radiography using highpower femtosecond laser

    International Nuclear Information System (INIS)

    Choi, Chang Il

    2010-08-01

    A femtosecond laser emits pulses whose width is between few and few hundreds femtoseconds (10 -15 s). The production mechanism of the high energy protons generated by the femtosecond laser is not clear so far, but the technologies have been improving. The applications using the generated protons are the proton therapy, proton radiography, nuclear physics, security inspection, and so on. Especially in the radiography, the laser-generated protons are very useful to obtain high quality images of thin objects, because protons are able to penetrate an object following an almost straight path and give a depth distribution information of various elements in a subject. Since the laser-driven protons require lower cost and smaller facility than accelerator-based protons, the radiography using laser-driven protons have been of interest. In this research, we have performed the radiography experiments by using protons generated by the 100 TW titanium sapphire femtosecond laser facility of Advanced Photonics Research Institute (APRI) of Gwangju Institute of Science Technology (GIST). A CR-39 Solid State Nuclear Track Detector (SSNTD) has been used as radiography screen. The radiography digital images have been obtained by using an optical microscope and a CCD camera. Modulation Transfer Function (MTF) has been derived from analyzing the obtained images, and the spatial resolution of the images have been evaluated. And, we have performed the radiography experiments of monoenergetic proton from the Tandem Van de Graaff accelerator of Korea Institute of Geoscience and Mineral Resources (KIGAM). We have obtained and compared the radiography images from other proton production methods which are the laser and the accelerator, respectively. And also, we have found out the optimized chemical etching condition, in order to improve the spatial resolution of the radiography images. Finally, the evaluated maximum spatial resolution of the images are 2.09 μm

  6. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  7. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  8. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  9. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  10. Neutron-induced alpha radiography; Radiografia com particulas alfa induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marco Antonio Stanojev

    2008-07-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the {alpha} - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 {mu}m in thickness can be inspected with a spatial resolution of 32 {mu}m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to {beta}, {gamma}, X-ray and visible light. (author)

  11. Screening Performance Characteristic of Ultrasonography and Radiography in Detection of Pleural Effusion; a Meta-Analysis.

    Science.gov (United States)

    Yousefifard, Mahmoud; Baikpour, Masoud; Ghelichkhani, Parisa; Asady, Hadi; Shahsavari Nia, Kavous; Moghadas Jafari, Ali; Hosseini, Mostafa; Safari, Saeed

    2016-01-01

    The role of ultrasonography in detection of pleural effusion has long been a subject of interest but controversial results have been reported. Accordingly, this study aims to conduct a systematic review of the available literature on diagnostic value of ultrasonography and radiography in detection of pleural effusion through a meta-analytic approach. An extended search was done in databases of Medline, EMBASE, ISI Web of Knowledge, Scopus, Cochrane Library, and ProQuest. Two reviewers independently extracted the data and assessed the quality of the articles. Meta-analysis was performed using a mixed-effects binary regression model. Finally, subgroup analysis was carried out in order to find the sources of heterogeneity between the included studies. 12 studies were included in this meta-analysis (1554 subjects, 58.6% male). Pooled sensitivity of ultrasonography in detection of pleural effusion was 0.94 (95% CI: 0.88-0.97; I2= 84.23, pultrasonography was found to be higher when the procedure was carried out by an intensivist or a radiologist using 5-10 MHz transducers. Chest ultrasonography, as a screening tool, has a higher diagnostic accuracy in identification of plural effusion compared to radiography. The sensitivity of this imaging modality was found to be higher when performed by a radiologist or an intensivist and using 5-10MHz probes.

  12. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  13. Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece) and Department of Natural Sciences, Technological Education Institute of Crete, P.O. Box 140, Iraklion 71004 Crete (Greece); Department of Radiology, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece); Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece)

    2009-10-15

    Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional

  14. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  15. New medical application: nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1977-01-01

    Nuclear scattering of 1 GeV protons is used to obtain three dimensional radiographies with a volume resolution of about 1 mm 3 . The information is different from the one given by X-ray radiographies and in particular one may get radiographies of the hydrogen included in objects. Results on a vertebral column and a 'sella turcica' are presented [fr

  16. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  17. Workshop on industrial isotope radiography: Programme and lectures

    International Nuclear Information System (INIS)

    1979-01-01

    The booklet contains the texts of lectures delivered in the Workshop on Industrial Radiography held at Bombay during 24-25 July 1979. The lectures cover some topics of relevance to industrial radiography. The topics are radiation protection and legislative aspects in industrial radiography; problems in field radiography in fertilizer industry, petrochemical industry and heavy engineering industry; occupational exposures in industrial radiography; and a review of the progress and recent trends in industrial radiographic techniques and equipment. (M.G.B.)

  18. Qualitative methods in radiography research: a proposed framework

    International Nuclear Information System (INIS)

    Adams, J.; Smith, T.

    2003-01-01

    Introduction: While radiography is currently developing a research base, which is important in terms of professional development and informing practice and policy issues in the field, the amount of research published by radiographers remains limited. However, a range of qualitative methods offer further opportunities for radiography research. Purpose: This paper briefly introduces a number of key qualitative methods (qualitative interviews, focus groups, observational methods, diary methods and document/text analysis) and sketches one possible framework for future qualitative work in radiography research. The framework focuses upon three areas for study: intra-professional issues; inter-professional issues; and clinical practice, patient and health delivery issues. While the paper outlines broad areas for future focus rather than providing a detailed protocol for how individual pieces of research should be conducted, a few research questions have been chosen and examples of possible qualitative methods required to answer such questions are outlined for each area. Conclusion: Given the challenges and opportunities currently facing the development of a research base within radiography, the outline of key qualitative methods and broad areas suitable for their application is offered as a useful tool for those within the profession looking to embark upon or enhance their research career

  19. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  20. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  1. Time resolved analysis of water drainage in porous asphalt concrete using neutron radiography.

    Science.gov (United States)

    Poulikakos, L D; Sedighi Gilani, M; Derome, D; Jerjen, I; Vontobel, P

    2013-07-01

    Porous asphalt as a road surface layer controls aquaplaning as rain water can drain through its highly porous structure. The process of water drainage through this permeable layer is studied using neutron radiography. Time-resolved water configuration and distribution within the porous structure are reported. It is shown that radiography depicts the process of liquid water transport within the complex geometry of porous asphalt, capturing water films, filled dead end pores and water islands. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Magnifying lens for 800 MeV proton radiography

    International Nuclear Information System (INIS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-01-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  3. Functioning of industrial radiography services

    International Nuclear Information System (INIS)

    Alves, R.N.; Costa, H.M. da; Bianchini, F.G.; Arrieta, L.A.I.

    1988-12-01

    The objective of this norm is establish the necessary requirements for the functioning of industrial radiography services, as well as the procedures for acquisition and transfer of radioactive sources and/or X-ray equipments used in industrial radiography [pt

  4. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  5. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  6. Industrial radiography techniques and their applications

    International Nuclear Information System (INIS)

    Wamorkar, R.R.

    1981-01-01

    Various aspects of industrial radiography are discussed. These include: radiation sources, geometrical unsharpness of image, radiation attenuation in the specimen, radiation effect of film, types of film, intensifying screens, exposure time calculations, source to film distance and sensivitity. Radiography techniques for examination of welded joints on flat plate and pipes or cylindrical objects, and castings are indicated. Applications of radiography in various industries are mentioned. (M.G.B.)

  7. Gonad Shielding during Pelvic Radiography: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Karami, Vahid; Zabihzadeh, Mansour; Shams, Nasim; Saki Malehi, Amal

    2017-02-01

    Gonad shielding has been extensively advocated during pelvic radiography at or below reproductive ages. The popular practice of gonad shielding is placement of a lead shield in the midline of the pelvis. The aim of this study was to address the prevalence of gonad shielding and find out whether the current practice of gonad shielding can be considered as an effective method to reduce radiation exposure in patients undergoing pelvic radiography. National and international electronic databases, including PubMed, MEDLIN, EMBASE, and Google-Scholar, were searched up to January 2016. The database searches were supplemented with manual searches of reference lists. Two authors independently assessed the eligibility of all studies and extracted data. The searches yielded a total of 243 publications. After assessing each identified study against specific inclusion exclusion criteria, 18 studies were deemed as relevant for this review. The total prevalence rate of gonad shielding was estimated at 58% (95% CI: 40 to 74%). It was estimated that only 34% (95% CI: 25 to 44%) of the radiographs had correct positioning of the shield. Also, incorrect positioning of the shield was statistically significantly higher in females than males (85% vs. 52 %; P-value gonad shielding during female pelvic radiography should be no longer considered as an effective method to reduce radiation exposure. Training the best qualified radiographers is the key to accurate positioning of the shield in male subjects.

  8. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  9. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  10. Dose reduction by x-ray beam filtration in screen-film radiography

    International Nuclear Information System (INIS)

    Koedooder, C.

    1986-01-01

    This thesis describes experimental and theoretical aspects of dose reduction by x-ray beam filtration in screen-film radiography. The thesis deals mainly with dose reduction under the constraint of constant image quality; an analytical approach is chosen. Therefore, part of the thesis deals with the development of an algorithm to calculate patient dose and exposure for different filter materials and different tube load conditions, under the constraint of constant contrast and constant optical density. (Auth.)

  11. An inventory of biomedical imaging physics elements-of-competence for diagnostic radiography education in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Caruana, Carmel J. [University of Malta, Institute of Health Care, St Lukes Hospital, Gwardamangia (Malta)]. E-mail: carmel.j.caruana@um.edu.mt; Plasek, Jaromir [Charles University, Faculty of Mathematics and Physics, Institute of Physics, Division of Biophysics, Prague (Czech Republic)

    2006-08-15

    Purpose: To develop an inventory of biomedical physics elements-of-competence for diagnostic radiography education in Europe. Method: Research articles in the English literature and UK documentation pertinent to radiography education, competences and role development were subjected to a rigorous analysis of content from a functional and competence analysis perspective. Translations of radiography curricula from across Europe and relevant EU legislation were likewise analysed to ensure a pan-European perspective. Broad Subject Specific Competences for diagnostic radiography that included major biomedical physics components were singled out. These competences were in turn carefully deconstructed into specific elements-of-competence and those elements falling within the biomedical physics learning domain inventorised. A pilot version of the inventory was evaluated by participants during a meeting of the Higher Education Network for Radiography in Europe (HENRE), held in Marsascala, Malta, in November 2004. The inventory was further refined taking into consideration suggestions by HENRE members and scientific, professional and educational developments. Findings: The evaluation of the pilot inventory was very positive and indicated that the overall structure of the inventory was sensible, easily understood and acceptable - hence a good foundation for further development. Conclusions: Use of the inventory by radiography programme leaders and biomedical physics educators would guarantee that all necessary physics elements-of-competence underpinning the safe, effective and economical use of imaging devices are included within radiography curricula. It will also ensure the relevancy of physics content within radiography education. The inventory is designed to be a pragmatic tool for curriculum development across the entire range of radiography education up to doctorate level and irrespective of whether curriculum delivery is discipline-based or integrated, presentation

  12. An inventory of biomedical imaging physics elements-of-competence for diagnostic radiography education in Europe

    International Nuclear Information System (INIS)

    Caruana, Carmel J.; Plasek, Jaromir

    2006-01-01

    Purpose: To develop an inventory of biomedical physics elements-of-competence for diagnostic radiography education in Europe. Method: Research articles in the English literature and UK documentation pertinent to radiography education, competences and role development were subjected to a rigorous analysis of content from a functional and competence analysis perspective. Translations of radiography curricula from across Europe and relevant EU legislation were likewise analysed to ensure a pan-European perspective. Broad Subject Specific Competences for diagnostic radiography that included major biomedical physics components were singled out. These competences were in turn carefully deconstructed into specific elements-of-competence and those elements falling within the biomedical physics learning domain inventorised. A pilot version of the inventory was evaluated by participants during a meeting of the Higher Education Network for Radiography in Europe (HENRE), held in Marsascala, Malta, in November 2004. The inventory was further refined taking into consideration suggestions by HENRE members and scientific, professional and educational developments. Findings: The evaluation of the pilot inventory was very positive and indicated that the overall structure of the inventory was sensible, easily understood and acceptable - hence a good foundation for further development. Conclusions: Use of the inventory by radiography programme leaders and biomedical physics educators would guarantee that all necessary physics elements-of-competence underpinning the safe, effective and economical use of imaging devices are included within radiography curricula. It will also ensure the relevancy of physics content within radiography education. The inventory is designed to be a pragmatic tool for curriculum development across the entire range of radiography education up to doctorate level and irrespective of whether curriculum delivery is discipline-based or integrated, presentation

  13. Experiments on muon radiography with emulsion track detectors

    International Nuclear Information System (INIS)

    Aleksandrov, Andrey; Bagulya, Alexander; Baklagin, Sergei; Chernyavsky, Mikhail; Galkin, Vladimir; Grachev, Victor; Konovalova, Nina; Managadze, Alexander; Polukhina, Natalya; Roganova, Tatiana; Starkov, Nikolai; Shchedrina, Tatiana; Tioukov, Valeri; Vladymirov, Mykhailo; Zemskova, Svetlana

    2016-01-01

    Muon radiography is a method of study the internal structure of large natural and industrial objects based on sensing an object with a flux of cosmic muons with their subsequent registration and analysis of the pattern of their dispersion, or conplete (or partial) absorption. The Lebedev Physical Institute of the Russian Academy of Sciences and the Skobeltsyn Institute of Nuclear Physics of Moscow State University have started a series of muon radiography experiments with nuclear emulsion detectors. As a result, the optimal conditions for experiment arrangement have been determined, algorithms of data processing have been worked out, and peculiarities of the method have been ultimately investigated

  14. Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging.

    Science.gov (United States)

    Tanaka, Rie

    2016-07-01

    Dynamic chest radiography is a flat-panel detector (FPD)-based functional X-ray imaging, which is performed as an additional examination in chest radiography. The large field of view (FOV) of FPDs permits real-time observation of the entire lungs and simultaneous right-and-left evaluation of diaphragm kinetics. Most importantly, dynamic chest radiography provides pulmonary ventilation and circulation findings as slight changes in pixel value even without the use of contrast media; the interpretation is challenging and crucial for a better understanding of pulmonary function. The basic concept was proposed in the 1980s; however, it was not realized until the 2010s because of technical limitations. Dynamic FPDs and advanced digital image processing played a key role for clinical application of dynamic chest radiography. Pulmonary ventilation and circulation can be quantified and visualized for the diagnosis of pulmonary diseases. Dynamic chest radiography can be deployed as a simple and rapid means of functional imaging in both routine and emergency medicine. Here, we focus on the evaluation of pulmonary ventilation and circulation. This review article describes the basic mechanism of imaging findings according to pulmonary/circulation physiology, followed by imaging procedures, analysis method, and diagnostic performance of dynamic chest radiography.

  15. Set theoretical aspects of real analysis

    CERN Document Server

    Kharazishvili, Alexander B

    2014-01-01

    This book addresses a number of questions in real analysis and classical measure theory that are of a set-theoretic flavor. Accessible to graduate students, the beginning of the book presents introductory topics on real analysis and Lebesque measure theory. These topics highlight the boundary between fundamental concepts of measurability and non-measurability for point sets and functions. The remainder of the book deals with more specialized material on set-theoretical real analysis. Problems are included at the end of each chapter.

  16. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  17. Neutron and gamma radiography with a research reactor

    International Nuclear Information System (INIS)

    Reijonen, Heikki

    1973-01-01

    The thesis consists of eight publications, which describe the instrumental analysis of both neutron and γ-radiography. The emphasis is on various research applications, especially solidification and segregation in Sn-Cd and Sn-In alloys. (L.M.K.)

  18. Radiation protection at industrial radiography in Germany exposures and unusual events

    International Nuclear Information System (INIS)

    Czarwinski, R.; Haeusler, U.; Frasch, G.

    2006-01-01

    In the Federal Republic of Germany safety related events in the use and transportation of radioactive materials as well as in the operation of accelerators are registered. The analysis of these events reveals their causation and allows this conclusions on avoidable errors. In this paper, a special insight is given into events in the field of gamma radiography which is a technical application of ionising radiation for non destructive testing of materials. Conclusions from analysis are drawn. In addition, the occupational radiation exposure of workers is presented taking into account that industrial radiography is performed under particular working conditions with different risks. (orig.)

  19. Dose-image quality study in digital chest radiography using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Correa, S.C.A.; Souza, E.M.; Silva, A.X.; Lopes, R.T.; Yoriyaz, H.

    2008-01-01

    One of the main preoccupations of diagnostic radiology is to guarantee a good image-sparing dose to the patient. In the present study, Monte Carlo simulations, with MCNPX code, coupled with an adult voxel female model (FAX) were performed to investigate how image quality and dose in digital chest radiography vary with tube voltage (80-150 kV) using air-gap technique and a computed radiography system. Calculated quantities were normalized to a fixed value of entrance skin exposure (ESE) of 0.0136 R. The results of the present analysis show that the image quality for chest radiography with imaging plate is improved and the dose reduced at lower tube voltage

  20. The added value of tomosynthesis in endoscopic retrograde cholangiography with radiography for the detection of choledocholithiasis.

    Science.gov (United States)

    Suyama, Yohsuke; Yamada, Yoshitake; Yamaguchi, Hideki; Someya, Gou; Otsuka, Seiji; Murayama, Yoshitami; Shinmoto, Hiroshi; Jinzaki, Masahiro; Ogawa, Kenji

    2018-04-16

    The diagnostic performance of endoscopic retrograde cholangiography (ERC) with radiography is imperfect. We assessed the value of adding tomosynthesis to ERC with radiography for the detection of choledocholithiasis. This study included 102 consecutive patients (choledocholithiasis/non-choledocholithiasis, n = 57/45), who underwent both radiography and tomosynthesis for ERC in the same examination and were not diagnosed with malignancy. The reference standard for the existence of choledocholithiasis was confirmed by endoscopic stone extraction during ERC, intraoperative cholangiography, or follow up with magnetic resonance cholangiopancreatography (n = 78, 11, and 13, respectively). A gastroenterologist and a radiologist independently evaluated the radiographs and the combination of tomosynthesis and radiographic images in a blinded and randomised manner. Receiver operating characteristic analysis was used for statistical analysis. The areas under the receiver operating characteristic curve for combined tomosynthesis and radiography were significantly higher than those for radiography alone for both readers: Reader 1/Reader 2, 0.929/0.956 [95% confidence interval (CI), 0.861-0.965/0.890-0.983) vs 0.803/0.769 (95% confidence interval, 0.707-0.873/0.668-0.846), respectively (p = 0.0047/tomosynthesis to radiography improved the diagnostic performance of ERC for detection of choledocholithiasis. Advances in knowledge: Adding tomosynthesis to radiography improves detection of choledocholithiasis and tomosynthesis images can be obtained easily after radiographs and repeated immediately.

  1. Effective dose in abdominal digital radiography: Patient factor

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Ji Sung; Koo, Hyun Jung; Park, Jung Hoon; Cho, Young Chul; Do, Kyung Hyun [Dept. of Radiology, and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul(Korea, Republic of); Yang, Hyung Jin [Dept. of Medical Physics, Korea University, Seoul (Korea, Republic of)

    2017-08-15

    To identify independent patient factors associated with an increased radiation dose, and to evaluate the effect of patient position on the effective dose in abdominal digital radiography. We retrospectively evaluated the effective dose for abdominal digital radiography in 222 patients. The patients were divided into two groups based on the cut-off dose value of 0.311 mSv (the upper third quartile of dose distribution): group A (n = 166) and group B (n = 56). Through logistic regression, independent factors associated with a larger effective dose were identified. The effect of patient position on the effective dose was evaluated using a paired t-test. High body mass index (BMI) (≥ 23 kg/m2), presence of ascites, and spinal metallic instrumentation were significantly associated with a larger effective dose. Multivariate logistic regression analysis revealed that high BMI [odds ratio (OR), 25.201; p < 0.001] and ascites (OR, 25.132; p < 0.001) were significantly associated with a larger effective dose. The effective dose was significantly lesser (22.6%) in the supine position than in the standing position (p < 0.001). High BMI and ascites were independent factors associated with a larger effective dose in abdominal digital radiography. Significant dose reduction in patients with these factors may be achieved by placing the patient in the supine position during abdominal digital radiography.

  2. Portable abdomen radiography. Moving to thickness-based protocols

    International Nuclear Information System (INIS)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A.

    2018-01-01

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  3. Portable abdomen radiography. Moving to thickness-based protocols

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Adrian A.; Reiser, Ingrid; Baxter, Tina; Zhang, Yue; Finkle, Joshua H.; Lu, Zheng Feng; Feinstein, Kate A. [University of Chicago Medical Center, Department of Radiology, Chicago, IL (United States)

    2018-02-15

    Default pediatric protocols on many digital radiography systems are configured based on patient age. However, age does not adequately characterize patient size, which is the principal determinant of proper imaging technique. Use of default pediatric protocols by inexperienced technologists can result in patient overexposure, inadequate image quality, or repeated examinations. To ensure diagnostic image quality at a well-managed patient radiation exposure by transitioning to thickness-based protocols for pediatric portable abdomen radiography. We aggregated patient thickness data, milliamperes (mAs), kilovoltage peak (kVp), exposure index (EI), source-to-detector distance, and grid use for all portable abdomen radiographs performed in our pediatric hospital in a database with a combination of automated and manual data collection techniques. We then analyzed the database and used it as the basis to construct thickness-based protocols with consistent image quality across varying patient thicknesses, as determined by the EI. Retrospective analysis of pediatric portable exams performed at our adult-focused hospitals demonstrated substantial variability in EI relative to our pediatric hospital. Data collection at our pediatric hospital over 4 months accumulated roughly 800 portable abdomen exams, which we used to develop a thickness-based technique chart. Through automated retrieval of data in our systems' digital radiography exposure logs and recording of patient abdomen thickness, we successfully developed thickness-based techniques for portable abdomen radiography. (orig.)

  4. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  5. WE-G-209-01: Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  6. Multi-energy method of digital radiography for imaging of biological objects

    Science.gov (United States)

    Ryzhikov, V. D.; Naydenov, S. V.; Opolonin, O. D.; Volkov, V. G.; Smith, C. F.

    2016-03-01

    This work has been dedicated to the search for a new possibility to use multi-energy digital radiography (MER) for medical applications. Our work has included both theoretical and experimental investigations of 2-energy (2E) and 3- energy (3D) radiography for imaging the structure of biological objects. Using special simulation methods and digital analysis based on the X-ray interaction energy dependence for each element of importance to medical applications in the X-ray range of energy up to 150 keV, we have implemented a quasi-linear approximation for the energy dependence of the X-ray linear mass absorption coefficient μm (E) that permits us to determine the intrinsic structure of the biological objects. Our measurements utilize multiple X-ray tube voltages (50, 100, and 150 kV) with Al and Cu filters of different thicknesses to achieve 3-energy X-ray examination of objects. By doing so, we are able to achieve significantly improved imaging quality of the structure of the subject biological objects. To reconstruct and visualize the final images, we use both two-dimensional (2D) and three-dimensional (3D) palettes of identification. The result is a 2E and/or 3E representation of the object with color coding of each pixel according to the data outputs. Following the experimental measurements and post-processing, we produce a 3D image of the biological object - in the case of our trials, fragments or parts of chicken and turkey.

  7. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  8. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  9. Imaging of bone tumors: evaluation of direct magnification radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Hillmann, A.; Erlemann, R.; Groenefeld, A.; Haeussler, M.; Heppe, A.E.; Vestring, T.; Peters, P.E.

    1996-01-01

    Objective. To evaluate the potentials of magnification radiography as compared with conventional radiography in diagnosing bone tumors. Design and patients. Sixty-two patients with primary bone tumors and tumorlike lesions underwent radiography with both conventional (non-magnified) and magnification (fivefold) techniques. All radiographs were analyzed by four radiologists and the findings correlated with the histopathology findings. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. Digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Results. The diagnosis of benign and malignant lesions as well as the individual tumor diagnosis were determined with higher accuracy using magnification compared with conventional radiography (88% vs 75% and 71% vs 52%, p<0.01). Margins of destruction, periosteal reactions and matrix patterns were evaluated with higher certainty by all of the radiologists (p<0.01). Conclusion. Magnification radiography may improve the evaluation and diagnosis of bone tumors. (orig.). With 6 tabs

  10. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  11. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  12. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  13. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  14. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  15. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  16. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  17. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  18. Process waste assessment for the Radiography Laboratory

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie (μCi) activity. The photochemical processes generate most of the Radiography Laboratory's routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance

  19. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  20. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  1. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  2. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  3. Radiography of pressure ulcers

    International Nuclear Information System (INIS)

    Borgstroem, P.S.; Ekberg, O.; Lasson, A.

    1988-01-01

    In patients with longstanding and/or deep pressure ulcers radiology is usually consulted. Survey radiography and sinography in 14 patients with pressure ulcers (6 over the tuber ischii and 8 over the femoral trochanter) were evaluated. Osteomyelitic involvement of adjacent bone was revealed in 9 patients on survey radiography. However, it was usually impossible to assess whether or not bony involvement represents healed or active osteomyelitis. Sinography did not contribute to the assessment of whether or not adjacent cortical bone was involved. However, when a fistulation to an adjacent joint was revealed this contributed substantially to the preoperative planning of resection. We therefore recommend that survey radiography and sinography should be included in the evaluation of these patients but that the results from such examinations are critically evaluated. Joint involvement should be taken seriously as progression of septic arthritis usually occurs rapidly. (orig.)

  4. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  5. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed. (author)

  6. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Full text: Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed

  7. Development of tungsten collimators for industrial radiography

    International Nuclear Information System (INIS)

    Varkey, P.A.; Verma, P.B.; Jayakumar, T.K.; Mammachan, M.K.

    2001-01-01

    Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)

  8. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  9. Digital and analogue industrial radiography, application fields

    International Nuclear Information System (INIS)

    Willems, Peter; Millord, Erik Yardin

    2000-01-01

    Full text: Reusable phosphor screens for computer radiography (CR), amorphous selenium screens for direct radiography (DR), film digitalisation (FD) constitute imaging methods accepted by industry and are used for non-destructive radiographic testing (RT). Economic pressures are involving and affecting digital RT technology. Standards and codes for film radiography and radioscopy qualification do no longer cover the wide range of digital RT applications. It will be our task to optimise the performance of digital RT characterisation and to create appropriate examination methods to use all these new and existent technologies. In the meantime, an increasing automation and control of manual methods of analogue radiography can as well be expected. (author)

  10. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  11. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  12. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  13. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  14. Trends that have influenced the Swedish radiography profession over the last four decades

    International Nuclear Information System (INIS)

    Andersson, B.T.; Lundgren, S.M.; Lundén, M.

    2017-01-01

    Introduction: The expansion of the radiography profession in recent decades has widened the scope of radiographic practice. This has raised questions about which trends have had an impact on the profession over the years. The study aim was to explore trends that have influenced the radiography profession over the last four decades. Methods: A qualitative design was used. Eleven focus group interviews inspired by the Scenario Planning Method were conducted at 11 diagnostic radiology departments in public hospitals in Sweden. The target group consisted of 48 registered radiographers. To analyse the data, qualitative content analysis was used. Results: Thematic data analysis revealed three broad categories; technological development and radiation doses, current status of the radiography profession and specialisation leading to expert knowledge. Each category derived from two or three sub-categories. Conclusion: The results demonstrate significant trends of influences on the radiography profession in Sweden over the last four decades. New methods and technology and control of radiation doses have had a favourable effect on the development of the radiography profession. Nevertheless, current status such as shortage of radiographers has had an adverse way. Specialisation leading to expert knowledge has an influence on career advancement and a specialist education regulated by the law, might be a prerequisite for the development of the radiography profession. - Highlights: • Scenario Planning Method, a relatively underutilised methodology, was used. • The findings report the influencing trends perceived by Swedish radiographers. • Technological development and radiation dose awareness impacted the profession. • Shortage, work shifting and higher independency influenced the profession. • Expert knowledge affects career advancement and requests specialist education.

  15. Root cause analysis of the radiation workers (radiography) in excess doses of NBD (case study: PT. XYZ)

    International Nuclear Information System (INIS)

    Arifin M Wibowo; Fajariadi; Aditia Anamta

    2013-01-01

    Negligence and non-compliance is the main factor of causing an incident in radiography. It shown as the result of TLD evaluation of PT. XYZ workers exceeding the dose limit (NBD). Root cause analysis stage begin in collecting data such as license, workers permit, dose, and incident sequence report. Causal chart is a tool to identification root cause to make easier of the analysis. Results of collecting data are to be clarified in BAPETEN investigation and then there are some a recommendation to facility. (author)

  16. Analysis of sculptures using XRF and X-ray radiography

    Science.gov (United States)

    Calza, C.; Oliveira, D. F.; Freitas, R. P.; Rocha, H. S.; Nascimento, J. R.; Lopes, R. T.

    2015-11-01

    This work reports the analysis of two sacred images on polychrome wood using X-ray Radiography and Energy Dispersive X-Ray Fluorescence. The first case is the analysis of a sculpture portraying Saint Sebastian, the patron saint of Rio de Janeiro, which is considered the second most ancient sacred image of Brazil. This sculpture was made in Portugal and was transported to Brazil by Estácio Sá, founder of the city of Rio de Janeiro, in 1565. Nowadays, it is located on the main altar of the Church of Capuchin Friars. The second case is the analysis of a sculpture representing Our Lady of Conception, which is located in the D. João VI Museum (EBA/UFRJ, Rio de Janeiro). The objective of these analyses was to evaluate the general conditions of the sculptures, identifying possible problems and internal damages, areas that revealed signs of previous retouchings and the materials and pigments employed by the artists, in order to assist its restoration procedures. EDXRF measurements were carried out with a portable system, developed at the Nuclear Instrumentation Laboratory, consisting of a Si-PIN XR-100CR detector from Amptek and an Oxford TF3005 X-ray tube with W anode. An X-ray source, a CR System GE CR50P and IP detectors were used to perform the radiographs. The XRF analysis of the sculptures identified the original pigments in both cases and the radiographic images revealed details of the manufacture; restored regions; extensive use of lead white; presence of cracks on the wood; use of nails and spikes, etc.

  17. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  18. Perceptions of radiography and the National Health Service: a qualitative study

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, C.R. E-mail: c.r.coombs@lboro.ac.uk; Park, J.R.; Loan-Clarke, J.; Arnold, J.; Preston, D.; Wilkinson, A.J

    2003-05-01

    Purpose: To identify the factors that determine the attractiveness of radiography as a career choice and of the National Health Service (NHS) as an employer to potential recruits and returners. Methods: Individual and group interviews were conducted in the East Midlands region to explore participants' perceptions of the attractiveness of the NHS as an employer to potential radiography staff. Interviews were conducted with school pupils, radiography students, mature students, radiography assistants, agency radiographers and independent sector radiographers. Results: Eighty-eight individuals participated in the qualitative stage of the study. Analysis of the interview transcripts indicated that radiography as a career choice is perceived as boring and routine, involving high workloads and little recognition from the general public. Working with patients is the source of considerable job satisfaction but is offset by staff shortages, lack of flexibility over working hours and a lack of consideration of family commitments in the NHS. Financial costs are highlighted as dissuading many participants from considering a career as a radiographer in the NHS or returning to work for the NHS. Greater use of open days in conjunction with more advertising of the profession is suggested as tactics to improve recruitment. Conclusions: The provision of more flexible working hours, greater consideration of family commitments and increased financial support for training are necessary to improve the attractiveness of a radiography career. NHS Human Resource Managers should consider these findings concerning the applicant and returner pools when developing strategies to address the current shortfall of radiographers.

  19. Perceptions of radiography and the National Health Service: a qualitative study

    International Nuclear Information System (INIS)

    Coombs, C.R.; Park, J.R.; Loan-Clarke, J.; Arnold, J.; Preston, D.; Wilkinson, A.J.

    2003-01-01

    Purpose: To identify the factors that determine the attractiveness of radiography as a career choice and of the National Health Service (NHS) as an employer to potential recruits and returners. Methods: Individual and group interviews were conducted in the East Midlands region to explore participants' perceptions of the attractiveness of the NHS as an employer to potential radiography staff. Interviews were conducted with school pupils, radiography students, mature students, radiography assistants, agency radiographers and independent sector radiographers. Results: Eighty-eight individuals participated in the qualitative stage of the study. Analysis of the interview transcripts indicated that radiography as a career choice is perceived as boring and routine, involving high workloads and little recognition from the general public. Working with patients is the source of considerable job satisfaction but is offset by staff shortages, lack of flexibility over working hours and a lack of consideration of family commitments in the NHS. Financial costs are highlighted as dissuading many participants from considering a career as a radiographer in the NHS or returning to work for the NHS. Greater use of open days in conjunction with more advertising of the profession is suggested as tactics to improve recruitment. Conclusions: The provision of more flexible working hours, greater consideration of family commitments and increased financial support for training are necessary to improve the attractiveness of a radiography career. NHS Human Resource Managers should consider these findings concerning the applicant and returner pools when developing strategies to address the current shortfall of radiographers

  20. Accelerated H-LBP-based edge extraction method for digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, Shuang; Zhao, Chen-yi; Huang, Ji-peng [School of Physics, Northeast Normal University, Changchun 130024 (China); Sun, Jia-ning, E-mail: sunjn118@nenu.edu.cn [School of Mathematics and Statistics, Northeast Normal University, Changchun 130024 (China)

    2015-01-11

    With the goal of achieving real time and efficient edge extraction for digital radiography, an accelerated H-LBP-based edge extraction method (AH-LBP) is presented in this paper by improving the existing framework of local binary pattern with the H function (H-LBP). Since the proposed method avoids computationally expensive operations with no loss of quality, it possesses much lower computational complexity than H-LBP. Experimental results on real radiographies show desirable performance of our method. - Highlights: • An accelerated H-LBP method for edge extraction on digital radiography is proposed. • The novel AH-LBP relies on numerical analysis of the existing H-LBP method. • Aiming at accelerating, H-LBP is reformulated as a direct binary processing. • AH-LBP provides the same edge extraction result as H-LBP does. • AH-LBP has low computational complexity satisfying real time requirements.

  1. Computational radiology in skeletal radiography

    International Nuclear Information System (INIS)

    Peloschek, Ph.; Nemec, S.; Widhalm, P.; Donner, R.; Birngruber, E.; Thodberg, H.H.; Kainberger, F.; Langs, G.

    2009-01-01

    Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment of alignment angles. Current results of computational image analysis in radiography are very promising, but some fundamental issues remain to be clarified, among which the definition of the optimal trade off between automatization and operator-dependency, the integration of these tools into clinical work flow and last not least the proof of incremental clinical benefit of these methods.

  2. Information extraction from muon radiography data

    International Nuclear Information System (INIS)

    Borozdin, K.N.; Asaki, T.J.; Chartrand, R.; Hengartner, N.W.; Hogan, G.E.; Morris, C.L.; Priedhorsky, W.C.; Schirato, R.C.; Schultz, L.J.; Sottile, M.J.; Vixie, K.R.; Wohlberg, B.E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  3. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  4. SIMPLE for industrial radiography

    International Nuclear Information System (INIS)

    Azhar Azmi; Abd Nassir Ibrahim; Siti Madiha Muhammad Amir; Glam Hadzir Patai Mohamad; Saidi Rajab

    2004-01-01

    The first thing industrial radiographers have to do before commencing radiography works is to determine manually the amount of correct exposure that the film need to be exposed in order to obtain the right density. The amount of exposure depends on many variables such as type of radioisotope, type of film, nature of test-object and its orientation, and specific arrangement related to object location and configuration. In many cases radiography works are rejected because of radiographs fail to meet certain reference criteria as defined in the applicable standard. One of the main reasons of radiograph rejection is due to inadequate exposure received by the films. SIMPLE is a software specially developed to facilitate the calculation of gamma-radiography exposure. By using this software and knowing radiographic parameters to be encountered during the work, it is expected that human error will be minimized, thus enhancing the quality and productivity of NDT jobs. (Author)

  5. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  6. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  7. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  8. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  9. Radiography with polarised neutrons

    International Nuclear Information System (INIS)

    Schulz, Michael L.

    2010-01-01

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd 1-x Ni x and Ni 3 Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd 1-x Ni x and Ni 3 Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni 3 Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T C on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with different ordering temperatures. This

  10. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography

    International Nuclear Information System (INIS)

    Souza, Luana Silva de

    2015-01-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  11. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.; Woodruff, K.H.; MacFarland, E.W.

    1983-01-01

    High energy, heavy-ion beams offer superior discrimination of tissue electron densities at very low radiation doses. This characteristic has potential for diagnostic medical imaging of neoplasms arising in the soft tissues and organs because it can detect smaller inhomogeneities than x rays. Heavy-ion imaging may also increase the accuracy of cancer radiotherapy planning involving use of accelerated charged particles. In the current physics research program of passive heavy-ion imaging, critical modulation transfer function tests are being carried out in heavy-ion projection radiography and heavy-ion computerized tomography. The research goal is to improve the heavy-ion imaging method until it reaches the limits of its theoretical resolution defined by range straggling, multiple scattering, and other factors involved in the beam quality characteristics. Clinical uses of the imaging method include the application of heavy-ion computerized tomography to heavy-ion radiotherapy planning, to the study of brain tumors and other structures of the head, and to low-dose heavy-ion projection mammography, particularly for women with dense breasts where other methods of diagnosis fail. The ions used are primarily 300 to 570 MeV/amu carbon and neon ions accelerated at the Lawrence Berkeley Laboratory Bevalac

  12. Industrial Radiography: Principle and Practical

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The successful and effectiveness of radiography method as a tool to increase quality level and safety of the engineering system and processing plants depend with the level of radiographer knowledge as service provider and also as supervisor. This book was published as effort several local experts to give their knowledge, theory and practical related to radiography technique to the involved public directly or indirectly. This book started with basic physic knowledge that becomes a root to radiography technology. Then, followed by discussion on tools and device that used in radiography work including x-ray machine, gamma projector, film, dark room, and others. Each aspect of radiograph quality also mentioned here to guide the reader on how to produce good radiograph that filled the specification wanted. The good radiograph does not mean anything if it failed to be interpreted correctly. Because of that, this book also explain how to choose good radiograph that qualified to be interpreted and after that how interpretation and evaluation process of object quality inspected was implemented based on image digestion that showed in radiograph. Several code and standard that usually applied in this country also will be referred as well for this work.

  13. Research on neutron radiography in Research Reactor Institute, Kyoto University and activities related to it

    International Nuclear Information System (INIS)

    Fujine, Shigenori; Yoneda, Kenji

    1994-01-01

    The research on neutron radiography in Research Reactor Institute, Kyoto University was begun in 1974 using the E-2 experimental hole which was designed for neutron irradiation. It was reconstructed for the excellent performance as neutron radiography facility by fixing aluminum plugs, a collimator and so on. The research activities thereafter are briefly described. In 1989, the cold neutron facility was installed in the graphite thermal neutron facility, and the experiment on cold neutron radiography became feasible. The reactor in Kyoto University is of the thermal output of 5 MW, and is put to the joint utilization by universities and research institutes in whole Japan. The experimental items carried out so far are enumerated. At present, the main subjects of research are the development of the standard for establishing image evaluation method, the analysis of gas-liquid two-phase flow, the construction of the data base for the literatures and images of neutron radiography, the application of cold neutron radiography, the development of the imaging method using fast neutrons and so on. The thermal neutron radiography and the cold neutron radiography facilities of Kyoto University research reactor are described. The research and activities at Kyoto University research reactor and the investigation of problems are reported. (K.I.) 56 refs

  14. An evaluation of author productivity in international radiography journals 2004–2011

    Energy Technology Data Exchange (ETDEWEB)

    Snaith, Beverly A [Radiology Department, Mid Yorkshire Hospitals NHS Trust, Pinderfields Hospital, Aberford Road (United Kingdom)

    2013-09-15

    Radiography, the allied health profession, has changed beyond recognition over the last century; however, in academic terms radiography is a relatively young profession. It is therefore still establishing its professional knowledge base. This article uses peer-review author productivity distribution to evaluate its scholarly maturity. Four peer-reviewed journals in medical radiation sciences were examined over an 8-year period (2004–2011) and author productivity was compared to Lotka's law. Further analysis of the most prolific authors provided an evaluation of their characteristics. The 1306 unique authors contributed 835 articles during the study period. Of these, 1012 (77.5%) contributed only one article to the journals studied, with an inverse power relationship of author productivity. At the 0.1 level of significance, radiography does not fit Lotka's law (n = −2.334; c = 0.712; D{sub max} = 0.0627; Critical threshold = 0.0337). There was a significant correlation between the most prolific authors and collaboration (P = 0.002), although variation was noted in author discipline and location. The results of this study add to the discussion of radiography scholarship and demonstrate that the radiography authors have similar productivity distribution to other professions, but do not follow Lotka's law.

  15. An evaluation of author productivity in international radiography journals 2004–2011

    International Nuclear Information System (INIS)

    Snaith, Beverly A

    2013-01-01

    Radiography, the allied health profession, has changed beyond recognition over the last century; however, in academic terms radiography is a relatively young profession. It is therefore still establishing its professional knowledge base. This article uses peer-review author productivity distribution to evaluate its scholarly maturity. Four peer-reviewed journals in medical radiation sciences were examined over an 8-year period (2004–2011) and author productivity was compared to Lotka's law. Further analysis of the most prolific authors provided an evaluation of their characteristics. The 1306 unique authors contributed 835 articles during the study period. Of these, 1012 (77.5%) contributed only one article to the journals studied, with an inverse power relationship of author productivity. At the 0.1 level of significance, radiography does not fit Lotka's law (n = −2.334; c = 0.712; D max = 0.0627; Critical threshold = 0.0337). There was a significant correlation between the most prolific authors and collaboration (P = 0.002), although variation was noted in author discipline and location. The results of this study add to the discussion of radiography scholarship and demonstrate that the radiography authors have similar productivity distribution to other professions, but do not follow Lotka's law

  16. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  17. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in … shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  18. Radiation Safety in Industrial Radiography. Specific Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  19. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  20. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  1. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  2. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  3. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  4. Neutron induced electron radiography; Radiografia com eletrons induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2008-07-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 {mu}m in 24 {mu}m of aluminum at a resolution of 32 {mu}m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  5. Measurement of Soot Deposition in Automotive Components Using Neutron Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Zekveld, David; Liu, Liaohui [AMEC NSS, 700 University Ave, Toronto, Ontario, M5G 1X6 (Canada); UOIT, 2000 Simcoe Street North, Oshawa, Ontario, L1H 7K4 (Canada); Harrison, Andrew; Gill, Spencer; Harvel, Glenn [UOIT, 2000 Simcoe Street North, Oshawa, Ontario, L1H 7K4 (Canada); Chang, Jen-Shih [McMaster University, 1280 Main Street West, Hamilton, Ontario, L8S 4L8 (Canada)

    2008-07-01

    About 40% of air pollution is generated by vehicles and transportation. The particulate matter (PM) emission significantly impacts human health. Fine particles below 2.5 {mu}m (PM2.5) can enter the lungs and lead to respiratory problems. These particles not only influence human health, but also reduce the capability of many automobile exhaust heat exchanging devices. Neutron radiography is a non-destructive method of analyzing carbonaceous PM. While neutron radiography has been demonstrated for soot measurement in the past, the application has not considered the presence of unburned hydrocarbons, significant amounts of moisture nor examined complex geometrical configurations. The purpose of this work is to study a reliable non-destructive testing methodology using neutron radiography for measurement of soot distribution in automotive components. A soot standard (aluminium target) was designed and manufactured as a calibration tool. The standard is radiographed and used to measure the differences between various soot thickness and compositions. The radiograph images are analyzed to determine a calibration curve based upon the composition of the materials which can then be used for analysis of the automotive components. Experiments are performed using a diesel engine to produce soot deposits on exhaust piping. Soot distribution on exhaust piping is measured using neutron radiography. (authors)

  6. Measurement of Soot Deposition in Automotive Components Using Neutron Radiography

    International Nuclear Information System (INIS)

    Zekveld, David; Liu, Liaohui; Harrison, Andrew; Gill, Spencer; Harvel, Glenn; Chang, Jen-Shih

    2008-01-01

    About 40% of air pollution is generated by vehicles and transportation. The particulate matter (PM) emission significantly impacts human health. Fine particles below 2.5 μm (PM2.5) can enter the lungs and lead to respiratory problems. These particles not only influence human health, but also reduce the capability of many automobile exhaust heat exchanging devices. Neutron radiography is a non-destructive method of analyzing carbonaceous PM. While neutron radiography has been demonstrated for soot measurement in the past, the application has not considered the presence of unburned hydrocarbons, significant amounts of moisture nor examined complex geometrical configurations. The purpose of this work is to study a reliable non-destructive testing methodology using neutron radiography for measurement of soot distribution in automotive components. A soot standard (aluminium target) was designed and manufactured as a calibration tool. The standard is radiographed and used to measure the differences between various soot thickness and compositions. The radiograph images are analyzed to determine a calibration curve based upon the composition of the materials which can then be used for analysis of the automotive components. Experiments are performed using a diesel engine to produce soot deposits on exhaust piping. Soot distribution on exhaust piping is measured using neutron radiography. (authors)

  7. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  8. Non-destructive analysis of ancient bimetal swords from western Asia by γ-ray radiography and X-ray fluorescence

    Science.gov (United States)

    Shizuma, Kiyoshi; Kajimoto, Tsuyoshi; Endo, Satoru; Matsugi, Kazuhiro; Arimatsu, Yui; Nojima, Hisashi

    2017-09-01

    Eight ancient bimetal swords held by Hiroshima University, Japan were analyzed non-destructively through γ-ray radiography and X-ray fluorescence (XRF). 137Cs and 60Co γ-ray irradiation sources were used to obtain transmission images of swords. A scanning radiography method using a 60Co γ-ray source was developed. XRF was used for qualitative elemental analysis of the swords. The presence of iron cores in the hilts of some swords had been observed and it was assumed that the cores were a ritual symbol or had a functional purpose. However, our work reveals that these swords were originally bronze-hilted iron swords and that the rusty blades were replaced with bronze blades to maintain the swords' commercial value as an antique. Consequently, the rest of the iron blade was left in the hilt as an iron tang. The junction of the blade and the guard was soldered and painted to match the patina color. XRF analysis clearly showed that the elemental Sn/Cu ratios of the blades and the hilts were different. These findings are useful for clarifying the later modifications of the swords and are important for interpreting Bronze Age and Iron Age history correctly.

  9. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  10. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  11. Digital radiography using scintillating screens

    International Nuclear Information System (INIS)

    Salvini, E.

    1988-01-01

    This paper briefly describes the technical features of a digital radiographic system based on the principle of scanning laser stimulated luminescence. Such aspects as the physics of the stimulable phosphor detector are dealt with, and image acquisition, processing, and hard-copy output. Automatic analysis of pixel histograms is described, in a qualitative way, together with contrast modifications and spatial filtering. Physical image characteristics are reported. The overall performance of digital radiography is examined, together with the current requirements and its eventual developments

  12. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  13. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  14. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  15. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  16. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  17. Need for New Optimisation Strategies in CR and Direct Digital Radiography

    International Nuclear Information System (INIS)

    Busch, H.P.

    2000-01-01

    Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference values for the dose and the image quality. This has to be done first for single exposures and fluoroscopic mode and secondly for diagnostic and interventional procedures. (author)

  18. Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

    Science.gov (United States)

    Moore, C S; Wood, T J; Beavis, A W; Saunderson, J R

    2013-07-01

    The purpose of this study was to examine the correlation between the quality of visually graded patient (clinical) chest images and a quantitative assessment of chest phantom (physical) images acquired with a computed radiography (CR) imaging system. The results of a previously published study, in which four experienced image evaluators graded computer-simulated postero-anterior chest images using a visual grading analysis scoring (VGAS) scheme, were used for the clinical image quality measurement. Contrast-to-noise ratio (CNR) and effective dose efficiency (eDE) were used as physical image quality metrics measured in a uniform chest phantom. Although optimal values of these physical metrics for chest radiography were not derived in this work, their correlation with VGAS in images acquired without an antiscatter grid across the diagnostic range of X-ray tube voltages was determined using Pearson's correlation coefficient. Clinical and physical image quality metrics increased with decreasing tube voltage. Statistically significant correlations between VGAS and CNR (R=0.87, pchest CR images acquired without an antiscatter grid. A statistically significant correlation has been found between the clinical and physical image quality in CR chest imaging. The results support the value of using CNR and eDE in the evaluation of quality in clinical thorax radiography.

  19. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  20. Radiography of steel castings by radioisotopes

    International Nuclear Information System (INIS)

    Agrawal, D.K.

    1977-01-01

    The salient features of isotope radiography techniques in the inspections of alloy castings are described. Some of the typical radiographic tests conducted in the Bharat Heavy Electricals Ltd., Bhopal and the problems encountered are described in detail. Specific examples are cited to enlighten the benefits of isotope radiography in heavy industries. (author)

  1. CONTENT ANALYSIS, DISCOURSE ANALYSIS, AND CONVERSATION ANALYSIS: PRELIMINARY STUDY ON CONCEPTUAL AND THEORETICAL METHODOLOGICAL DIFFERENCES

    Directory of Open Access Journals (Sweden)

    Anderson Tiago Peixoto Gonçalves

    2016-08-01

    Full Text Available This theoretical essay aims to reflect on three models of text interpretation used in qualitative research, which is often confused in its concepts and methodologies (Content Analysis, Discourse Analysis, and Conversation Analysis. After the presentation of the concepts, the essay proposes a preliminary discussion on conceptual and theoretical methodological differences perceived between them. A review of the literature was performed to support the conceptual and theoretical methodological discussion. It could be verified that the models have differences related to the type of strategy used in the treatment of texts, the type of approach, and the appropriate theoretical position.

  2. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  3. Radiography inspection of weld for nuclear fuel rod

    International Nuclear Information System (INIS)

    Zhang Kai; Zhang Xichang

    1995-05-01

    The survey of radiography inspection, advantages, disadvantages and applications of main kinds of radiography inspection methods are presented. Emphasis is put upon the structure and functions of X-ray flaw detecting device for nuclear fuel rod welds, the actuating program of the device, as well as the structure of some key mechanism and the functions of them. The analysis is made upon the actuating principles. Finally, the test of long-term operation proves the device to be stable in operation, reliable in action, to possess high level of automation and high sensitivity and it can simultaneously perform on-line X-ray inspection of 25 nuclear fuel rods with a diameter less than 10 mm, and meet the requirements of large-scale production of nuclear fuel rods (5 figs.)

  4. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... industrial radiography. An application for a specific license for the use of licensed material in industrial...

  5. Lateral radiography of the knee with single-leg standing

    International Nuclear Information System (INIS)

    Ohmori, Kan; Sugawara, Tsuyoshi; Murakami, Katsuyoshi; Kirinai, Mikio; Fujiwara, Junichi; Oikawa, Takumi; Matsumura, Yutaka; Sugawara, Tsukasa

    2002-01-01

    The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography. (author)

  6. Utility of routine postoperative chest radiography in pediatric tracheostomy.

    Science.gov (United States)

    Genther, Dane J; Thorne, Marc C

    2010-12-01

    Routine chest radiography following pediatric tracheostomy is commonly performed in order to evaluate for air-tracking complications. Routine chest radiography affords disadvantages of radiation exposure and cost. The primary objective of this study was to determine the utility of routine postoperative chest radiography following tracheostomy in pediatric patients. Secondary objectives were to compare the rates of postoperative complications by various patient and surgeon characteristics. All infants and children 18 years of age or less (n=421) who underwent tracheostomy at a single tertiary-care medical center from January 2000 to April 2009 were included in the study. A combination of data obtained from billing and administrative systems and review of electronic medical records were recorded and compiled in a database for statistical analysis. Three air-tracking complications (2 pneumothoraces and 1 pneumomediastinum) were identified in our population of 421 pediatric patients, for an incidence of 0.71% (95% CI: 0.1-2.0%). No significant relationships were found between the incidence of air-tracking complication and surgical specialty, patient age, or type of procedure (elective, urgent/emergent). Our study identified a low rate of pneumothorax and pneumomediastinum following pediatric tracheostomy. In all three cases, the pneumothorax was suspected clinically. This finding suggests that postoperative chest radiography should be reserved for cases where there is suspicion of a complication on the basis of intraoperative findings or clinical parameters. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Personnel exposures in industrial radiography

    International Nuclear Information System (INIS)

    Shenoy, K.S.; Patel, P.H.

    1979-01-01

    The manifold increase in production, and ease of availability of radioisotopes in India have been responsible for a tremendous increase in use of radioisotopes in industrial radiography during past fifteen years. Among various applications of radioisotopes the industrial radiography involves a large potential risk of occupational radiation exposures. The dose records of past fifteen years in respect of all radiation workers maintained by the Personnel Monitoring Group of Division of Radiological Protection of the Bhabha Atomic Research Centre, Bombay, have been analysed. Analysis of excessive exposure (exceeding 400 mrem/fortnight) reveals that this figure is increasing at an alarming rate among the radiation workers of this category. In spite of various regulatory controls the dose per person per week has remained higher as compared to the same in other categories. This combined with the increase in number of radiation workers every year would soon contribute significantly to the per capita dose for radiation workers. Use of adequately shielded fool-proof remote control equipment and training of all personnel in safe handling of radiation sources seem to be the only solution to arrest the rate of increase in personnel exposures of this category. (auth.)

  8. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  9. Industrial radiography

    International Nuclear Information System (INIS)

    Aloni, A.; Magal, O.

    1992-02-01

    This publication is meant to be a manual for industrial radiography. As such the manual concentrates on the practical aspects, presenting existing radiographic system and techniques of operation to satisfy specified quality requirements. The manual also reviews the safety aspect of performing radiographic work. (author) systems

  10. Skull Radiography

    Science.gov (United States)

    What you need to know about… Skull Radiography X-ray images of the skull are taken when it is necessary to see the cranium, facial bones or jaw bones. ... Among other things, x-ray exams of the skull can show fractures. Patient Preparation Before the examination, ...

  11. Analysis of the spatial rates dose rates during dental panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jong Kyung [Dept. of Radiation Safety Management Commission, Daegu Health College, Daegu (Korea, Republic of); Park, Myeong Hwan [Dept. of Radiologic Technology, Daegu Health College, Daegu (Korea, Republic of); Kim, Yong Min [Dept. of Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2016-12-15

    A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a 45°, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is 3,840 μSv/h, which is four times higher than the lowest level 778 μSv/h. Furthermore, the spatial dose rate was 408 μSv/h on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

  12. Security of radioactive sources in industrial radiography

    International Nuclear Information System (INIS)

    Popp, Andrew; Murray, Allan

    2010-01-01

    This paper describes the need and new requirements to ensure the security of radioactive sources used in the practice of industrial radiography. We describe the discussions and issues arising during the september 2010 regional workshop held in Sydney on the application of security measures to industrial radiography practices. The workshop provided the perspectives of both radiation regulators and industry practitioners, including those from the Philippines. We describe the outputs of the workshop, and how they were developed, and make suggestions for further consideration and applications of security measures in the practice of industrial radiography. (author)

  13. Charter of good practices in industrial radiography

    International Nuclear Information System (INIS)

    2010-01-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  14. Corrosion Surveillance In Pipe By Computed Radiography

    International Nuclear Information System (INIS)

    Nguyen The Man; Dao Duy Dung; Dang Thu Hong; Le Duc Thinh; Ha Hong Thu; Nguyen Trong Nghia

    2014-01-01

    Computed Radiography (CR) is a technique of digital industrial radiology which is developed to replace conventional radiography. With a CR system, the detection of the outer and inner wall surface of the pipe is done usually by edge detection and filter algorithms of the profile line at the position under investigation. Applying in industries, radiographic examination shall be performed in accordance with a written procedure. This paper summarizes collected knowledge and experimental results to establish a procedure for radiography applications in monitoring corrosion in small bore pipes. (author)

  15. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  16. Application of computed radiography to ERCP

    International Nuclear Information System (INIS)

    Lee, Shigeki; Mochizuki, Fukuji; Fujita, Naotaka; Itoh, Shoichiro; Ikeda, Takashi; Toyohara, Tokiaki; Matsumoto, Kyoichi

    1984-01-01

    Computed radiography technic was applied to ERCP. Fuji Computed Radiography System was used. The pancreatogram obtained by this method was compared with that of conventional screen-film radiograph. The much finer changes of the pancreatogram can be delineated by the new method. The diagnostic ability of ERCP is thus enhanced by the introduction of FCR. (author)

  17. Spectroscopic neutron radiography for a cargo scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Rahon, Jill [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Danagoulian, Areg, E-mail: aregjan@mit.edu [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); MacDonald, Thomas D. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Hartwig, Zachary S. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Lanza, Richard C. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States)

    2016-06-01

    Detection of cross-border smuggling of illicit materials and contraband is a challenge that requires rapid, low-dose, and efficient radiographic technology. The work we describe here is derived from a technique which uses monoenergetic gamma rays from low energy nuclear reactions, such as {sup 11}B(d,nγ){sup 12}C, to perform radiographic analysis of shipping containers. Transmission ratios of multiple monoenergetic gamma lines resulting from several gamma producing nuclear reactions can be employed to detect materials of high atomic number (Z), the details of which will be described in a separate paper. Inherent in this particular nuclear reaction is the production of fast neutrons which could enable neutron radiography and further characterization of the effective-Z of the cargo, especially within the range of lower Z. Previous research efforts focused on the use of total neutron counts in combination with X-ray radiography to characterize the hydrogenous content of the cargo. We present a technique of performing transmitted neutron spectral analysis to reconstruct the effective Z and potentially the density of the cargo. This is made possible by the large differences in the energy dependence of neutron scattering cross-sections between hydrogenous materials and those of higher Z. These dependencies result in harder transmission spectra for hydrogenous cargoes than those of non-hydrogenous cargoes. Such observed differences can then be used to classify the cargo based on its hydrogenous content. The studies presented in this paper demonstrate that such techniques are feasible and can provide a contribution to cargo security, especially when used in concert with gamma radiography.

  18. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  19. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  20. Digital radiography and caries diagnosis.

    Science.gov (United States)

    Wenzel, A

    1998-01-01

    Direct digital acquisition of intra-oral radiographs has been possible only in the last decade. Several studies have shown that, theoretically, there are a number of advantages of direct digital radiography compared with conventional film. Laboratory as well as controlled clinical studies are needed to determine whether new digital imaging systems alter diagnosis, treatment and prognosis compared with conventional methods. Most studies so far have evaluated their diagnostic performance only in laboratory settings. This review concentrates on what evidence we have for the diagnostic efficacy of digital systems for caries detection. Digital systems are compared with film and those studies which have evaluated the effects on diagnostic accuracy of contrast and edge enhancement, image size, variations in radiation dose and image compression are reviewed together with the use of automated image analysis for caries diagnosis. Digital intra-oral radiographic systems seem to be as accurate as the currently available dental films for the detection of caries. Sensitivities are relatively high (0.6-0.8) for detection of occlusal lesions into dentine with false positive fractions of 5-10%. A radiolucency in dentine is recognised as a good predictor for demineralisation. Radiography is of no value for the detection of initial (enamel) occlusal lesions. For detection of approximal dentinal lesions, sensitivities, specificities as well as the predictive values are fair, but are very poor for lesions known to be confined to enamel. Very little documented information exists, however, on the utilization of digital systems in the clinic. It is not known whether dose is actually reduced with the storage phosphor system, or whether collimator size is adjusted to fit sensor size in the CCD-based systems. There is no evidence that the number of retakes have been reduced. It is not known how many images are needed with the various CCD systems when compared with a conventional bitewing

  1. Radiography of X-ray in coral reefs

    International Nuclear Information System (INIS)

    Djoli Soembogo

    2016-01-01

    The application of X-ray radiography has been developed and it is already widely used in metal materials such as metal steel and carbon steel. This radiography using a source of radiation from X-ray machines. This research attempts to use the application of digital radiography X-ray source and use scanner Epson V700 positive films media for digitization results of conventional radiographic films on coral reefs. It has been testing radiography using Fuji film 100 to get the contrast medium, the sensitivity of the medium and image quality is good, Single Wall Single Image method , and using the media scanner films positive and X-ray sources, observation parameter are density radiographic film and the defect shape. Radiography uses Fuji film 100 to obtain a good contrast medium, good medium sensitivity and good quality image. Radiography of X-ray on coral reefs aims to find defects or discontinuities coral reefs such as porosity which would interfere with the determination of the age of the coral reefs. X-ray exposure time is 1 seconds for a thickness of 5.45 mm and 5.60 mm coral reefs by using a high voltage X-ray machine Rigaku of 130 kV. The result of the positive film scanner in the form of digital radiography that allows for the transfer of digital data or digital computerized data storage. The test results of radiographic on coral reefs with Single Wall Single Image method obtained radiographic film density parameter for Fuji film 100 on coral reefs No. 2 are 2.55; 2.53; 2.59 and on coral reefs No. 4 are 2.62; 2.65; 2.66, unsharpness geometric of radiographic results obtained 0.022 mm and 0.023 mm, sensitivity radiography are 1.648% and 1.604%. No defect found of Porosity that is significant. Status is acceptable for Fuji film 100, because the density of the film is in conformity with the standards referred to. Status of coral reefs No. 2 and No. 4 can be accepted, because it has conformed with the standards referred. (author)

  2. Feasibility study of gamma-ray medical radiography

    International Nuclear Information System (INIS)

    Alyassin, Abdalmajeid M.; Maqsoud, Hamza A.; Mashat, Ahmad M.; Al-Mohr, Al-Sayed; Abdulwajid, Subhan

    2013-01-01

    This research explores the feasibility of using gamma-ray radiography in medical imaging. We will show that gamma-ray medical radiography has the potential to provide alternative diagnostic medical information to X-ray radiography. Approximately one Ci Am-241 radioactive source which emits mono-energetic 59.5 keV gamma rays was used. Several factors that influence the feasibility of this study were tested. They were the radiation source uniformity, image uniformity, and image quality parameters such as contrast, noise, and spatial resolution. In addition, several gamma-ray and X-ray images were acquired using humanoid phantoms. These images were recorded on computed radiography image receptors and displayed on a standard monitor. Visual assessments of these images were then conducted. The Am-241 radioactive source provided relatively uniform radiation exposure and images. Image noise and image contrast were mainly dependent on the exposure time and source size, whereas spatial resolution was dependent on source size and magnification factor. The gamma-ray humanoid phantom images were of lower quality than the X-ray images mainly due to the low radioactivity used and not enough exposure time. Nevertheless, the gamma-ray images displayed most of the main structures contained in the humanoid phantoms. Higher exposure rates and thus lower exposure times were estimated for different pure Am-241 source sizes that are hypothesized to provide high quality images similar to X-ray images. For instance, a 10 mm source size of pure Am-241 with 7 s exposure time should produce images similar in contrast and noise to X-ray images. This research paves the way for the production and usage of a highly radioactive Am-241 source with the potential to lead to the feasibility of acceptable quality medical gamma-ray radiography. - Highlights: ► Characterized the performance of gamma-ray radiography. ► Displayed medical images of humanoid phantoms using gamma radiography. ► Am-241

  3. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  4. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  5. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  6. Fundamental research on isotherm capillary absorption of concrete by neutron radiography

    International Nuclear Information System (INIS)

    Kanematsu, Manabu; Tsuchiya, Naoko; Noguchi, Takafumi

    2013-01-01

    This study focuses on the absorption process of concrete to determine the influence of aggregates on the local water behavior in concrete, by using neutron radiography. At first, water quantification method by using thermal neutron radiography is summarized which is developed in previous researches. With this method, the water absorption process was examined in concrete specimens containing artificial cylindrical aggregates. Using the obtained hydraulic diffusivity, an unsteady water diffusion analysis captured the experimentally observed water distribution around the aggregates. The result shows that the water behavior can be well explained by the geometric layout of the aggregates. (author)

  7. Measurement of Liquid-Metal Two-Phase Flow with a Dynamic Neutron Radiography

    International Nuclear Information System (INIS)

    Cha, J. E.; Lim, I. C.; Kim, H. R.; Kim, C. M.; Nam, H. Y.; Saito, Y.

    2005-01-01

    The dynamic neutron radiography(DNR) has complementary characteristics to X-ray radiography and is suitable to visualization and measurement of a multi-phase flow research in a metallic duct and liquid metal flow. The flow-field information of liquid metal system is very important for the safety analysis of fast breeder reactor and the design of the spallation target of accelerator driven system. A DNR technique was applied to visualize the flow field in the gas-liquid metal two-phase flow with the HANARO-beam facility. The lead bismuth eutectic and the nitrogen gas were used to construct the two-phase flow field in the natural circulation U-channel. The two-phase flow images in the riser were taken at various combinations of the liquid flow and gas flow with high frame-rate neutron radiography at 1000 fps

  8. Gravity sag view of lateral radiography of the knee

    International Nuclear Information System (INIS)

    Hidaka, Kuniyuki; Yanagawa, Yasuhiro; Kawamoto, Kiyosumi; Maeda, Daisuke; Komizu, Mitsuru

    2007-01-01

    The gravity sag view (GSV) is a lateral radiograph taken in the same position when the posterior sag sign is observed. The purpose of this study was to standardize the radiography technique for GSV by adjusting lateral rotation. To confirm the benchmark and correction angle (CA) for the GSV position, we assessed three-dimensional (3D) CT of the GSV position of the knee using normal volunteers. The benchmark is established at the 3-point of the leg and adjusting the CA of the knee is established by estimating from Rosenberg technique radiography. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate in adjusting lateral radiography of the knee. (author)

  9. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  10. Opportunities for TRIGA reactors in neutron radiography

    International Nuclear Information System (INIS)

    Barton, John P.

    1978-01-01

    In this country the two most recent installations of TRIGA reactors have both been for neutron radiography, one at HEDL and the other at ANL. Meanwhile, a major portion of the commercial neutron radiography is performed on a TRIGA fueled reactor at Aerotest. Each of these installations has different primary objectives and some comparative observations can be drawn. Another interesting comparison is between the TRIGA reactors for neutron radiography and other small reactors that are being installed for this purpose such as the MIRENE slow pulse reactors in France, a U-233 fueled reactor for neutron radiography in India and the L88 solution reactor in Denmark. At Monsanto Laboratory, in Ohio, a subcritical reactor based on MTR-type fuel has recently been purchased for neutron radiography. Such systems, when driven by a Van de Graaff neutron source, will be compared with the standard TRIGA reactor. Future demands on TRIGA or competitive systems for neutron radiography are likely to include the pulsing capability of the reactor, and also the extraction of cold neutron beams and resonance energy beams. Experiments recently performed on the Oregon State TRIGA Reactor provide information in each of these categories. A point of particular current concern is a comparison made between the resonance energy beam intensity extracted from the edge of the TRIGA core and from a slot which penetrated to the center of the TREAT reactor. These results indicate that by using such slots on a TRIGA, resonance energy intensities could be extracted that are much higher than previously predicted. (author)

  11. Digital radiography: a survey of pediatric dentists.

    Science.gov (United States)

    Russo, Julie M; Russo, James A; Guelmann, Marcio

    2006-01-01

    The purpose of this study was to: (1) determine the popularity of digital radiography among members of the American Academy of Pediatric Dentistry (AAPD); and (2) report the most common systems in use. An AAPD-approved, voluntary, and anonymous electronic survey was developed and sent to 923 board certified pediatric dentists. Years in practice and in-office x-ray technology (digital or conventional) were inquired about initially. If negative for the use of digital radiography, future consideration for converting to digital radiography was ascertained. For positive responses, more in-depth information was requested. Information on type of system (sensor or phosphor plate), user friendliness, diagnostic ability, patient's comfort, general costs, durability, and parental and overall satisfaction was collected. For most of the questions, a 5-point assessment scale was used. Opportunity for additional comments was provided upon survey completion. Data was analyzed using descriptive statistics. A 32% (296/923) response rate was obtained. Twenty-six percent of practitioners (78/296) implemented digital radiography in their practices, whereas 71% considered future acquisition. Similar distribution for sensor and phosphor plate users was found. Sensor technology was reported to produce faster images, but was less tolerable by young children due to size and thickness. Phosphor plates were considered more children friendly, less expensive, and less durable. Parental satisfaction was very high with great marketing value. Picture quality was comparable to conventional film. Overall, digital radiography users would recommend it to other pediatric dentists. Digital radiography is not yet popular among pediatric dentists. Cost reduction and technology advancement may enhance utilization.

  12. An audit of follow-up chest radiography after coronary artery bypass graft

    Energy Technology Data Exchange (ETDEWEB)

    Karthik, S. [Department of Cardiothoracic Surgery, Yorkshire Heart Centre, Leeds General Infirmary, Leeds (United Kingdom); O' Regan, D.J. [Department of Cardiothoracic Surgery, Yorkshire Heart Centre, Leeds General Infirmary, Leeds (United Kingdom)]. E-mail: regan@leedsth.nhs.uk

    2006-07-15

    AIM: To investigate the clinical value and audit chest radiography, which is currently undertaken as part of routine practice, in the follow-up of coronary artery bypass graft (CABG) patients. MATERIAL AND METHODS: Six hundred and sixty-six first time CABG patients were identified from the Patient Analysis and Tracking System database representing the work of a single surgeon between February 2001 and September 2005. The data regarding the clinical and radiological findings on follow-up were collected from the follow-up clinic letters and case notes. Any need for re-admission/intervention was also noted. RESULTS: Of the 666 patients, 11 died and a further 10 either refused or failed to arrive for follow-up. Chest radiography was undertaken in 645 patients. Only 13 patients (2%) were found to have an abnormality on chest radiography. In all cases this was a pleural effusion that was confirmed on clinical examination in seven patients (53.9%) patients. Only one patient needed re-admission and intervention. In this case the effusion had been noted on clinical examination. Seven patients were discharged and the remaining five were followed up with repeat chest radiography before discharge. Seventy-four patients had a respiratory complication postoperatively, but only three had any evidence of an effusion on follow-up. CONCLUSION: The diagnostic yield of a routine chest radiography in a CABG follow-up clinic is low (2%) and the need for intervention is rare and is determined by clinical examination. The practice of routine radiography in this group of patients has now stopped and follow-up audit will be conducted in 12 months.

  13. Application of proton radiography to medical imaging

    International Nuclear Information System (INIS)

    Kramer, S.L.; Martin, R.L.; Moffett, D.R.; Colton, E.

    1977-12-01

    The use of charged particles for radiographic applications has been considered for some time, but progress has been impeded by the cost and availability of suitable accelerators. However, recent developments in technology could overcome these problems. A review is presented of the physical principles leading to an improvement in mass resolution per unit of absorbed dose for charged particle radiography relative to x-ray radiography. The quantitative comparisons between x-ray and proton radiographs presented here confirm this advantage. The implications of proton radiography on cancer detection, as well as future plans for developing a proton tomographic system, are discussed

  14. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  15. Mathematics and physics of neutron radiography

    International Nuclear Information System (INIS)

    Harms, A.A.; Wyman, D.R.

    1985-01-01

    This book provides detailed descriptions and analyses of selected experiments and their mathematical characterization. Also included are illustrative and quantitative procedures for applications. This book also discusses the radiography, nondestructive testing and nuclear reactor utilization. The contents discussed are: I: Introduction. II: Component Characterization. III: Object-Image Relations. IV: Rectangular Geometry. V: Cylindrical Geometry. VI: Two-Dimensional Analysis. VII: Object Scattering. VIII: Linear Systems Formulation. IX: Selected Topics. X: Neutron Radiographs. XI: Bibliography and References. Subject Index

  16. Development of computer assisted learning program using cone beam projection for head radiography

    International Nuclear Information System (INIS)

    Nakazeko, Kazuma; Araki, Misao; Kajiwara, Hironori; Watanabe, Hiroyuki; Kuwayama, Jun; Karube, Shuhei; Hashimoto, Takeyuki; Shinohara, Hiroyuki

    2012-01-01

    We present a computer assisted learning (CAL) program to simulate head radiography. The program provides cone beam projections of a target volume, simulating three-dimensional computed tomography (CT) of a head phantom. The generated image is 512 x 512 x 512 pixels with each pixel 0.6 mm on a side. The imaging geometry, such as X-ray tube orientation and phantom orientation, can be varied. The graphical user interface (GUI) of the CAL program allows the study of the effects of varying the imaging geometry; each simulated projection image is shown quickly in an adjoining window. Simulated images with an assigned geometry were compared with the image obtained using the standard geometry in clinical use. The accuracy of the simulated image was verified through comparison with the image acquired using radiography of the head phantom, subsequently processed with a computed radiography system (CR image). Based on correlation coefficient analysis and visual assessment, it was concluded that the CAL program can satisfactorily simulate the CR image. Therefore, it should be useful for the training of head radiography. (author)

  17. The industrial radiography of defects inside the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt; Kaempf, B.

    1976-03-01

    The concept of the industrial radiography applied to defect invesigation is defined. The following topics are successively discussed: the development of the industrial 'defect radiography', apparatus and auxiliary equipments used in the field, the market, the constructors, trade currents in 'defect radiography' inside the Community and in the outer market; prognostics on future requirements in the fields

  18. Diagnostic value of digital radiography compared to conventional screen-film system combinations

    International Nuclear Information System (INIS)

    Krug, B.; Zaehringer, M.; Lackner, K.

    1997-01-01

    Digital projection radiography provides digital data in X-ray examinations, which used to be carried out by examinations screen-film system combinations. The technological basis and clinical performances of digital luminescent radiography (DLR) and digital radiography are reviewed. Digital projection radiography does not allow to reduce selenium exposure significantly, compared to screen-film system combinations. Digital luminescent radiography can be used for the entire spectrum of analogous projection radiography the only exception being extremely subtile structural changes. The clinical experiences with digital selenium radiography achieved so far in chest X-rays are promising and the technique is expected to be increasing used in other anatomic regions as well. (orig.) [de

  19. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dong Hee; KIm, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

  20. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    International Nuclear Information System (INIS)

    Hong, Dong Hee; KIm, Hyeong Gyun

    2016-01-01

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test

  1. Code of practice in industrial radiography

    International Nuclear Information System (INIS)

    Karma, S. E. M.

    2010-12-01

    The aim of this research is to developing a draft for a new radiation protection code of practice in industrial radiography without ignoring that one issued in 1998 and meet the current international recommendation. Another aim of this study was to assess the current situation of radiation protection in some of the industrial radiography department in Sudan. To achieve the aims of this study, a draft of a code of practice has been developed which is based on international and local relevant recommendations. The developed code includes the following main issues: regulatory responsibilities, radiation protection program and design of radiation installation. The practical part of this study includes scientific visits to two of industrial radiography departments in Sudan so as to assess the degree of compliance of that department with what state in the developed code. The result of each scientific visits revealed that most of the department do not have an effective radiation protection program and that could lead to exposure workers and public to unnecessary dose. Some recommendations were stated that, if implemented could improve the status of radiation protection in industrial radiography department. (Author)

  2. Safety culture in industrial radiography facility

    International Nuclear Information System (INIS)

    Vincent-Furo, Evelyn

    2015-02-01

    This project reviewed published IAEA materials and other documents on safety culture with specific references to industrial radiography. Safety culture requires all duties important to safety to be carried out correctly, with alertness, due thought and full knowledge, sound judgment and a proper sense of accountability. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements. The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve a high degree of safety culture appropriate national and international infrastructure should exist to ensure effective training of workers and management system that supports commitment to safety culture at all level of the organization; management, managers and workforce. The result of the review revealed that all accidents in industrial radiography facilities were due to poor safety culture practices including inadequate regulatory control oversight. Some recommendations are provided and if implemented could improve safety culture leading to good safety performance which will significantly reduce accidents and their consequences in industrial radiography. These examples call for a review of safety culture in Industrial radiography. (au)

  3. Multi-energy radiography for non-destructive testing of materials and structures for civil engineering

    International Nuclear Information System (INIS)

    Naydenov, S.V.; Ryzhikov, V.

    2003-01-01

    Development of the technological base of modern non-destructive testing require new methods allowing determination of specified properties of materials and structures under study. A traditional direction of works is determination of internal spatial structure of the materials and other constructions. Restoration of this geometrical information is of qualitative character, though provides for determination of technical parameters affecting physical properties of the system. Reconstruction of the chemical composition, density and atomic structure (effective atomic number) is an inverse problem of direct quantitative determination of properties starting from data obtained by means of non-destructive testing. In the present work, we propose the use of multi-energy radiography for reconstruction of the substantial structure of materials. In framework of simple theoretical model it is shown that, using multi-channel absorption of X-rays, important substantial characteristics of materials and multi-compound structures can be readily reconstructed. The results obtained show high efficiency of 2-energy radiography for non-destructive testing in civil engineering

  4. X-ray imaging using amorphous selenium: photoinduced discharge (PID) readout for digital general radiography.

    Science.gov (United States)

    Rowlands, J A; Hunter, D M

    1995-12-01

    Digital radiographic systems based on photoconductive layers with the latent charge image readout by photoinduced discharge (PID) are investigated theoretically. Previously, a number of different systems have been proposed using sandwiched photoconductor and insulator layers and readout using a scanning laser beam. These systems are shown to have the general property of being very closely coupled (i.e., optimization of one imaging characteristic usually impacts negatively on others). The presence of a condensed state insulator between the photoconductor surface and the readout electrode does, however, confer a great advantage over systems using air gaps with their relatively low breakdown field. The greater breakdown field of condensed state dielectrics permits the modification of the electric field during the period between image formation and image readout. The trade-off between readout speed and noise makes this system suitable for instant general radiography and even rapid sequence radiography, however, the system is unsuitable for the low exposure rates used in fluoroscopy.

  5. Portable radiography using linear accelerators

    International Nuclear Information System (INIS)

    Reid, D.W.

    1984-01-01

    There are numerous instances where the availability of a portable high-energy radiography machine that could be transported to the inspection site with relative ease would save time, money, and make radiography of permanent installations, such as bridges, possible. One such machine, the Minac built by Schoenberg Radiation Inc., is commercially available. It operates at 9.3 GHz, has an electron energy on target of 3.5 MeV, and an output dose rate of 100 R/min. A second portable accelerator, recently completed at the Los Alamos National Laboratory, operates at 2.998 GHz, has electron energies on target of 6, 8, and 10 MeV, and an output dose rate of 800 R/min at 8 MeV. This paper discusses the need for and applications of portable accelerators for radiography. Physical characteristics and beam parameters of both machines are examined in detail. Problems of operating at higher frequencies to further minimize size and weight are discussed

  6. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Computed Radiography Exposure Indices in Mammography. L Koen, C Herbst, W Rae. Abstract. Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose ...

  7. Use of cost benefit analysis in the field of industrial radiography

    International Nuclear Information System (INIS)

    Croft, J.R.; Webb, G.A.M.; Tattersall, P.; Sutherland, A.; Spence, E.

    1988-01-01

    Over the past decade NRPB has had a program of work on the development of cost benefit analysis (CBA) techniques in the optimisation of radiological protection. A provisional framework for including suggestions for assigning a value to unit collective dose was published for consultation in 1981/82 and after various interim statements this process culminated in formal advice in 1986. As part of this work, and as part of a project for the Commission of the European Communities (CEC) the NRPB has carried out a number of case studies to demonstrate the practical implementation of ALARA or optimisation of protection using CBA. These techniques, used in conjunction with ALARA audits, are now in general use in the NRPB's Radiation Protection Advisor Service. They have been used for a variety of medical and industrial situations, but mainly in industrial radiography as this is the part of the non-nuclear sector where occupational exposure problems predominate. Three cases are presented as representative examples

  8. Application of direct digital radiography of nasal bone

    International Nuclear Information System (INIS)

    Gao Dengfa; Wang Haijun; Zhang Ailian; Wang Yulin

    2005-01-01

    Objective: To research the application value of direct digital radiograph (DDR ) in nasal bone imaging. Methods: One hundred cases were examined by DDR, 30 cases of them were examined by two methods both DDR and conventional radiography. All digital images were post-processed with 'MUSICA' (Multi-Scale Image Contrast Amplification), incision and largamente, analyzed and diagnosed by experienced two radiologists and two technicians. Results: One hundred cases of nasal bone, soft tissue of nose were showed excellent in DDR, and satisfactory cases were 95 and 92, respectively. Forty-six cases of nasal bone fractures were found. Thirty cases were examined by both DDR and conventional radiography, images of nasal bone, soft tissue of nose were showed, satisfactory cases were 28 in DDR; and satisfactory cases were 6 (χ 2 =20.05, P 2 =15.06, P 2 =5.14, P<0.05) in conventional and digital radiography, respectively. Conclusion: DDR images of nasal bone, soft tissue of nose was excellent, more fractures were discovered than conventional radiography. Image quality of DDR is better than conventional radiography in nasal bone imaging. (authors)

  9. Satisfaction of Search in Chest Radiography 2015.

    Science.gov (United States)

    Berbaum, Kevin S; Krupinski, Elizabeth A; Schartz, Kevin M; Caldwell, Robert T; Madsen, Mark T; Hur, Seung; Laroia, Archana T; Thompson, Brad H; Mullan, Brian F; Franken, Edmund A

    2015-11-01

    Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P chest radiography (P chest radiography has changed, but it is not clear why. SOS may be changing as a function of changes in radiology education and practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  10. Radiography with cosmic-ray and compact accelerator muons; Exploring inner-structure of large-scale objects and landforms.

    Science.gov (United States)

    Nagamine, Kanetada

    2016-01-01

    Cosmic-ray muons (CRM) arriving from the sky on the surface of the earth are now known to be used as radiography purposes to explore the inner-structure of large-scale objects and landforms, ranging in thickness from meter to kilometers scale, such as volcanic mountains, blast furnaces, nuclear reactors etc. At the same time, by using muons produced by compact accelerators (CAM), advanced radiography can be realized for objects with a thickness in the sub-millimeter to meter range, with additional exploration capability such as element identification and bio-chemical analysis. In the present report, principles, methods and specific research examples of CRM transmission radiography are summarized after which, principles, methods and perspective views of the future CAM radiography are described.

  11. Bacteriological research for the contamination of equipment in chest radiography

    International Nuclear Information System (INIS)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol

    2015-01-01

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections

  12. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  13. Radiation-absorbed doses and energy imparted from panoramic tomography, cephalometric radiography, and occlusal film radiography in children

    International Nuclear Information System (INIS)

    Bankvall, G.; Hakansson, H.A.

    1982-01-01

    The absorbed doses and energy imparted from radiographic examinations of children, using panoramic tomography (PTG), cephalometric radiography (CPR), and maxillary frontal occlusal overview (FOO), were examined. The absorbed dose at various sites of the head were measured with TL dosimeters in a phantom and in patients. The energy imparted was calculated from measurements of areal exposure using a planparallel ionization chamber. The maximum absorbed doses for panoramic tomography were located around the lateral rotation center, for cephalometric radiography in the left (tube side) parotid region, and for frontal occlusal radiography in the nose. The absorbed doses in the eyes, thyroid gland, and skin are discussed and compared with previous reports and, for the most part, are found to be in agreement. The mean energy imparted from all three examination methods is 5 mJ with about 57 percent from panoramic, 33 percent from cephalometric, and 10 percent from frontal occlusal examinations. The energy imparted from cephalometric radiography can be reduced to about 10 percent with the use of an improved examination technique, leaving panoramic tomography responsible for contributing about 80 percent of the total energy imparted

  14. Reproducible positioning in chest X-ray radiography

    International Nuclear Information System (INIS)

    1974-01-01

    A device is described that can be used to ensure reproducibility in the positioning of the patient during X-ray radiography of the thorax. Signals are taken from an electrocardiographic monitor and from a device recording the respiratory cycle. Radiography is performed only when two preselected signals coincide

  15. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  16. Visualization of frosting phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Yoshimura, Tomoya; Matsumoto, Ryosuke; Umekawa, Hisashi; Ami, Takeyuki; Saito, Yasushi

    2012-01-01

    This study focuses on the frost formation on the fin-tube heat exchanger using neutron radiography. The visualization of the frost formation was estimated by the attenuation of the neutron beam through the water. The visualization image of the neutron radiography shows clearly the frost formation phenomena on the fin-tube heat exchanger. The rapid frost formation was observed at the fin and tube edges. Local mass transfer coefficient can be calculated from the differential images of the neutron radiography. (author)

  17. Filmless Radiography

    Science.gov (United States)

    1997-01-01

    Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

  18. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION... Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  19. Safety guide of safe use of industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    The objective of this guidance is to present general regulations for the safe use and radiation protection of industrial radiography. Storage and inspection of apparatus, personal instructions for working in radiography facilities are offered

  20. Radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Panaiotov, L N

    1951-10-23

    A new method of hollow articles radiography is presented enabling to eliminate shortcomings coupled with medical personnel irradiation when the ampoule incorporating radioactive substance is removed from the protective container and adjusted in the article. The method presented permits to transport the ampoule from the protective container immediately into the inner cavity of the article.

  1. The “dirty chest”—correlations between chest radiography, multislice CT and tobacco burden

    Science.gov (United States)

    Kirchner, J; Goltz, J P; Lorenz, F; Obermann, A; Kirchner, E M; Kickuth, R

    2012-01-01

    Objectives Cigarette smoking-induced airway disease commonly results in an overall increase of non-specific lung markings on chest radiography. This has been described as “dirty chest”. As the morphological substrate of this condition is similar to the anthracosilicosis of coal workers, we hypothesised that it is possible to quantify the radiological changes using the International Labour Organization (ILO) classification of pneumoconiosis. The aims of this study were to evaluate whether there is a correlation between the extent of cigarette smoking and increased lung markings on chest radiography and to correlate the chest radiographic scores with findings on CT studies. Methods In a prospective analysis a cohort of 85 smokers was examined. The cigarette consumption was evaluated in pack years (defined as 20 cigarettes per day over 1 year). Film reading was performed by two board-certified radiologists. Chest radiographs were evaluated for the presence of thickening of bronchial walls, the presence of linear or nodular opacities, and emphysema. To correlate the smoking habits with the increase of overall lung markings in chest radiography, the ILO profusion score was converted to numbers ranging from zero to nine. Chest radiographs were rated according to the complete set of standard films of the revised ILO classification. Results 63/85 (74%) of the smokers showed an increase in overall lung markings on chest radiography; 32 (37%) had an ILO profusion score of chest radiography and the cigarette consumption quantified as pack years (r=0.68). The majority of the heavy smokers (>40 pack years) showed emphysema; there was no significant difference between the prevalence of emphysema as diagnosed by CT (62%) or chest radiography (71%) (pchest radiography. PMID:21937617

  2. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    Science.gov (United States)

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  3. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  4. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  5. X-ray fluorescence and computed radiography analysis of a famous brazilian painting from XIX century

    International Nuclear Information System (INIS)

    Calza, Cristiane; Oliveira, Davi F.; Rocha, Henrique S.; Lopes, Ricardo Tadeu

    2009-01-01

    This work used Energy Dispersive X-Ray Fluorescence (EDXRF) and Computed Radiography (CR) to evaluate the general conditions of the painting 'Gioventu' (Eliseu Visconti, 1898), identifying possible problems, areas that revealed signs of previous retouchings and the pigments used by the artist. EDXRF measurements were carried out with a portable system consisting of an X-ray tube Oxford TF3005 with W anode, operating at 25 kV and 100 μA, and a Si-PIN XR-100CR detector from Amptek. Several spectra were obtained in each color, with an acquisition time of 300 s and a beam collimation of 2 mm. The spectra were analyzed using the software QXAS-AXIL (IAEA). The results revealed that the drawings were made over a preparatory layer of lead white. Some pigments identified were: yellow, red and brown ochre; umbra; vermilion; cobalt blue; etc. The experimental setup used in the CR analysis consisted of an Oxford X-ray source, operating at 50 kV and 200 μA, placed at 85 cm from the painting, a GE CR 50P portable computed radiography scanner and a Fuji imaging plate detector. The exposure time was 600 s. The radiographic images revealed that the painting was in a good state of conservation and also a complete composition hidden underneath the visible paint layer.(author)

  6. X-ray fluorescence and computed radiography analysis of a famous brazilian painting from XIX century

    Energy Technology Data Exchange (ETDEWEB)

    Calza, Cristiane; Oliveira, Davi F.; Rocha, Henrique S.; Lopes, Ricardo Tadeu [Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear], e-mail: ccalza@lin.ufrj.br; Pedreira, Andrea [Museu Nacional de Belas Artes, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This work used Energy Dispersive X-Ray Fluorescence (EDXRF) and Computed Radiography (CR) to evaluate the general conditions of the painting 'Gioventu' (Eliseu Visconti, 1898), identifying possible problems, areas that revealed signs of previous retouchings and the pigments used by the artist. EDXRF measurements were carried out with a portable system consisting of an X-ray tube Oxford TF3005 with W anode, operating at 25 kV and 100 {mu}A, and a Si-PIN XR-100CR detector from Amptek. Several spectra were obtained in each color, with an acquisition time of 300 s and a beam collimation of 2 mm. The spectra were analyzed using the software QXAS-AXIL (IAEA). The results revealed that the drawings were made over a preparatory layer of lead white. Some pigments identified were: yellow, red and brown ochre; umbra; vermilion; cobalt blue; etc. The experimental setup used in the CR analysis consisted of an Oxford X-ray source, operating at 50 kV and 200 {mu}A, placed at 85 cm from the painting, a GE CR 50P portable computed radiography scanner and a Fuji imaging plate detector. The exposure time was 600 s. The radiographic images revealed that the painting was in a good state of conservation and also a complete composition hidden underneath the visible paint layer.(author)

  7. Compton radiography, 4. Magnification compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, S; Sera, K; Shishido, F; Fukuda, H [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis and Cancer; Mishina, H

    1978-03-01

    Compton radiography permits an acquisition of direct magnification Compton radiograms by use of a pinhole collimator, rendering it feasible to overcome the resolution of the scinticamera being employed. An improvement of resolution was attained from 7 mm to 1 mm separation. Usefulness of its clinical application can be seen in orientation of puncture and biopsy in deep structures and detection of various foreign bodies penetrated by blasts and so on under the ''magnification Compton fluoroscopy'' which can be developed on this principle in the near future.

  8. Time-grated energy-selected cold neutron radiography

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Brun, T.O.; Claytor, T.N.; Farnum, E.H.; Greene, G.L.; Morris, C.

    1998-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as Time-Gated Energy-Selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross section drops significantly. This difference in scattering characteristics can be recorded in the TGES radiography and, because the Bragg cutoff occurs at different energy levels for various materials, the approach can be used to differentiate among these materials. This paper outlines the TGES radiography technique and shows an example of radiography using the approach

  9. Intramodality and intermodality agreement in radiography and computed tomography of equine distal limb fractures.

    Science.gov (United States)

    Crijns, C P; Martens, A; Bergman, H-J; van der Veen, H; Duchateau, L; van Bree, H J J; Gielen, I M V L

    2014-01-01

    Computed tomography (CT) is increasingly accessible in equine referral hospitals. To document the level of agreement within and between radiography and CT in characterising equine distal limb fractures. Retrospective descriptive study. Images from horses that underwent radiographic and CT evaluation for suspected distal limb fractures were reviewed, including 27 horses and 3 negative controls. Using Cohen's kappa and weighted kappa analysis, the level of agreement among 4 observers for a predefined set of diagnostic characteristics for radiography and CT separately and for the level of agreement between the 2 imaging modalities were documented. Both CT and radiography had very good intramodality agreement in identifying fractures, but intermodality agreement was lower. There was good intermodality and intramodality agreement for anatomical localisation and the identification of fracture displacement. Agreement for articular involvement, fracture comminution and fracture fragment number was towards the lower limit of good agreement. There was poor to fair intermodality agreement regarding fracture orientation, fracture width and coalescing cracks; intramodality agreement was higher for CT than for radiography for these features. Further studies, including comparisons with surgical and/or post mortem findings, are required to determine the sensitivity and specificity of CT and radiography in the diagnosis and characterisation of equine distal limb fractures. © 2013 EVJ Ltd.

  10. Radiation protection in dental radiography

    International Nuclear Information System (INIS)

    Jozani, F.; Parnianpour, H.

    1976-08-01

    In considering the special provisions required in dental radiography, investigations were conducted in Iran. Radiation dose levels in dental radiography were found to be high. Patient exposure from intraoral radiographic examination was calculated, using 50kV X-ray. Thermoluminescent dosimeters were fastened to the nasion, eyes, lip, philtrum, thyroid, gonads and to the right and left of the supra-orbital, infra-orbital temporomandibular joints of live patients. The highest exposure value was for the lower lip. Recommendations concerning educational training and protection of staff and patients were included

  11. Educational aspects of industrial radiography

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Wamorkar, R.R.; Singh, G.

    1979-01-01

    The state of art of training and education in non-destructive testing in India, with special reference to industrial radiography is reviewed. Basic requirement of industry and potential of radioisotopes in industrial inspection are also described. Need for an organised training programme in industrial isotope radiography to exploit potentials for benefit of industry concurrent with the safety is stressed. A comprehensive training programme tailored to meet the needs of Indian industry is outlined. Benefits obtained from the course to the industry since the beginning of the training programme are briefly reviewed. (auth.)

  12. Muon radiography method for fundamental and applied research

    Science.gov (United States)

    Alexandrov, A. B.; Vladymyrov, M. S.; Galkin, V. I.; Goncharova, L. A.; Grachev, V. M.; Vasina, S. G.; Konovalova, N. S.; Malovichko, A. A.; Managadze, A. K.; Okat'eva, N. M.; Polukhina, N. G.; Roganova, T. M.; Starkov, N. I.; Tioukov, V. E.; Chernyavsky, M. M.; Shchedrina, T. V.

    2017-12-01

    This paper focuses on the basic principles of the muon radiography method, reviews the major muon radiography experiments, and presents the first results in Russia obtained by the authors using this method based on emulsion track detectors.

  13. Studies on the Fuji computed radiography depended on the panoramic radiography

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Shiota, Satoru; Takazawa, Kazuyoshi; Yoshida, Toru; Takagi, Yoshiko; Funamoto, Choichiro

    1986-01-01

    The Fuji Computed Radiography (FCR) developed recently involves the following procedures; photography in the same way as the hitherto radiography, printing auto imaging plate of photostimulable phospher, conversion to electric signals, and recording reproduced images by computerization. Highly valuable images for diagnoses in the medical field have already been obtained by the FCR. Then, we attempted to study FCR images panoramically radiographed for jaw lesions in the field of oral surgery. Method for study: As the samples to be studied, the selected subjects were cases of periodontal diseases, fracture of the jaw, odontogenic cyst and tumor, etc. In the present study the FCR images of panoramic radiography were compared with hitherto panoramic flat radiograms. Result of study: Although the images of the FCR vary depending on the methods of treatment, that is, on how gradient processing and spatial frequency enhancement are, the method of purpose-fitting treatment provided diagnostically significant images for grasping bone lesions. The images obtained from this FCR permitted us to grasp more distinctly condition of alveolar bone resorption in periodontal diseases, running of minute fracture lines in fracture of the jaw, and characteristic images of bone resorption in odontogenic cysts and tumor, etc. Thus the images of the FCR are highly useful in diagnosing bone lesions, but granularity of the images themselves have still been questioned, and additionally the images vary depending on the methods of gradient processing and spatial frequency enhancement. Therefore further repeat studies are probably needed for these questions. (author)

  14. Reconstructive dosimetry of radiological accidents - study of a brazilian case of industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, Francisco Cesar Augusto da; Hunt, John G.; Ramalho, Adriana; Pinto, Livia M.F. Amalfi

    2002-01-01

    On May 2000, an industrial gamma radiography operator, during a maintenance work of a 60 Co irradiator, has suffered a radiological accident with severe consequences to the left hand. The experts of the High Doses Analysis Group (GADE/IRD/CNEN) initiated the reconstructive dosimetry for the radiation dose estimation, in order to determine the real dose received by the operator, and to help the medical evaluation for prescribing the medical procedures for treatment of the involved victim. This paper presents the reconstructive dosimetry performed through the determination of the radiation doses of the operator, based on theoretical, experimental and computational methods. For the computer methods, a program for the calculation of external doses were used, based on the Monte Carlo method, and a human body simulator composed by voxels. The values of effective and equivalent doses are also presented which has caused severe lesions on the operator hand

  15. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  16. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  17. Mathematical and theoretical neuroscience cell, network and data analysis

    CERN Document Server

    Nieus, Thierry

    2017-01-01

    This volume gathers contributions from theoretical, experimental and computational researchers who are working on various topics in theoretical/computational/mathematical neuroscience. The focus is on mathematical modeling, analytical and numerical topics, and statistical analysis in neuroscience with applications. The following subjects are considered: mathematical modelling in Neuroscience, analytical  and numerical topics;  statistical analysis in Neuroscience; Neural Networks; Theoretical Neuroscience. The book is addressed to researchers involved in mathematical models applied to neuroscience.

  18. Inspection of welded joints and cords using industrial x-ray and gamma radiography

    International Nuclear Information System (INIS)

    Escobar R, E.J.

    2000-01-01

    The first part of this work contains five chapters related to theoretical aspects and basic knowledge of welding metallurgy, welding, welded joint discontinuity, non-destructive testing (NDT) and industrial x-rays. The second part contains experimental works applied and carried out by the Peruvian Institute of Nuclear Energy (IPEN). Due to the importance of identifying and applying the different methods of NDT in the industry's quality control, more emphasis is placed on industrial x-ray and gamma radiography, a method that involves the radiographic inspection of welded joints and cords

  19. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  20. Introduction to industrial radiography

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the first topic in this book, more on introduction to nondestructive testing, also a little bit on another technique such as magnetic testing, liquid penetrated, ultrasonic testing and others. This book mentions more on radiographic testing and for that, more details on this topic such as history, definition and devices that use in this technique. This radiography testing firstly started with the discovering of x-ray by Wilhelm Roentgen (1895). So, on 1913, David Coolidge successfully invented and developed x-ray tube that could made x-ray more intensified and produced highly penetration forces. Radiography in Malaysia firstly started two years after the discovery made by Wilhelm Roentgen when one hospital here used the x-ray machine for medical purposes. Besides using x-ray, radiography also used gamma rays, and for these purpose, they used Co-60 and Ir-192. Now, more company based on NDT established to provide a service on inspection pipe and others. For filled these requirement, radiographer must take an exam to make them expert and trained well to work in this field. There is no advantage using this technique or other technique. So that's why this book was published to make people understand what is radiographic testing truly.

  1. Problems associated with veterinary dental radiography

    International Nuclear Information System (INIS)

    Eisner, E.R.

    1990-01-01

    Veterinarians have been radiographing animal skulls for many years, but sophisticated dentistry was not widely used until the 1970s. Elevated awareness of veterinary dental techniques has led to the need for producing accurate radiographic images of the teeth and periodontal structures. Many problems arise for the clinician who treats small animals who has, before this time, radiographed the skull of dogs and cats solely for the purpose of assessing neoplastic, infectious, or traumatic disease of the mandible, maxilla, or calvarium and now desires to perform dental radiography. This chapter will describe the advantages and disadvantages of some of the more common types of radiographic equipment and supplies, discuss extraoral and intraoral radiographic positioning and technique, identify anatomic landmarks and diagnostic features of intraoral radiography, and offer suggestions concerning the art of using dental radiography in veterinary practice

  2. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  3. Industrial Radiography Safety in Australia

    International Nuclear Information System (INIS)

    Hockings, Colin

    2006-01-01

    The first applications of the imaging capability of X-rays were non-medical. Roentgen produced images of his shotgun, a compass and a set of weights in a closed box to show his colleagues. Prior to 1912, X-rays were used little outside the realms of medicine and dentistry because the X-ray tubes failed under the higher voltages required for industrial purposes. However, that changed in 1913 when high vacuum X-ray tubes designed by Coolidge became available. In 1922, industrial radiography took another step forward with the advent of the 200,000-volt X-ray tube that allowed radiographs of thick steel parts to be produced in a reasonable amount of time. In 1931 the American Society of Mechanical Engineers (ASME) permitted approval of fusion welded pressure vessels by x-ray, which promoted an acceptance and use of the method. That application continues. Radium became the initial gamma ray source for industrial radiography. The material allowed radiography of castings up to 30cm thick. During World War II, industrial radiography grew significantly as part of the US Navy's shipbuilding-program, and in 1946 gamma ray sources such as cobalt 60 and iridium 192 became available. These new sources gained rapid popularity because they emitted more intense radiation than radium and were less expensive. Present state: the majority of industrial radiography techniques have changed little since their inception. An image is captured, processed and analysed for evidence of fault or defect. Today however, the images are of higher quality and greater sensitivity, through the use of better quality films, smaller radiation sources and automated processing. Developments in electronics and computers now allow technicians to create a digital image, enhance it, transmit it or store it indefinitely. The most noticeable change in industrial radiography equipment from the technician's view would be the reduction in weight of the equipment for a given kV output. Never the less it remains

  4. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference

    International Nuclear Information System (INIS)

    Choo, Ji Yung; Lee, Ki Yeol; Choi, Jung Won; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Kang, Eun-Young; Oh, Yu Whan

    2016-01-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p < 0.05). DTS image quality was significantly better than chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. (orig.)

  5. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  6. Development of cosmic-ray radiography with nuclear emulsion and its applications

    International Nuclear Information System (INIS)

    Morishima, Kunihiro

    2017-01-01

    We are developing cosmic-ray radiography with nuclear emulsion. Cosmic-ray radiography is non-destructive inspection technology to take image of inner structure of gigantic objects (nuclear reactor, pyramids, volcanoes and so on). We conducted cosmic-ray radiography of Fukushima Daiichi Nuclear Power Plant from 2014 to 2015 and are conducting cosmic-ray radiography of Pyramids at Egypt from 2015. In this paper, technical details and latest results are presented. (author)

  7. Optimization of exposure factors for X-ray radiography non-destructive testing of pearl oyster

    Science.gov (United States)

    Susilo; Yulianti, I.; Addawiyah, A.; Setiawan, R.

    2018-03-01

    One of the processes in pearl oyster cultivation is detecting the pearl nucleus to gain information whether the pearl nucleus is still attached in the shell or vomited. The common tool used to detect pearl nucleus is an X-ray machine. However, an X-ray machine has a drawback that is the energy used is higher than that used by digital radiography. The high energy make the resulted image is difficult to be analysed. One of the advantages of digital radiography is the energy used can be adjusted so that the resulted image can be analysed easily. To obtain a high quality of pearl image using digital radiography, the exposure factors should be optimized. In this work, optimization was done by varying the voltage, current, and exposure time. Then, the radiography images were analysed using Contrast to Noise Ratio (CNR). From the analysis, it can be determined that the optimum exposure factors are 60 kV of voltage, 16 mA of current, and 0.125 s of exposure time which result in CNR of 5.71.

  8. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  9. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  10. Validation of Computed Radiography (CR) Exposure Chart for Stainless Steel and Aluminium

    International Nuclear Information System (INIS)

    Nassir, M.A.; Khairul Anuar Mohd Salleh; Arshad Yassin

    2015-01-01

    Computed radiography (CR) is a technique that is currently used to complement the conventional radiography in Non Destructive Testing (NDT). With CR, phosphorous base imaging plate (IP) is used to acquire digital radiographic images. The degree of absorption by the IP is proportional to the intensity of the dose received. The IP stores latent image which subsequently digitized by the CR reader. Prior to radiography exposure, the radiation dosage is determined by referring to the exposure chart. Exposure chart is one of the most important tools for achieving acceptable quality radiographs. Therefore, it is important to have a reliable and accurate exposure chart. The aim of this study is to test and validate exposure charts that were developed based on the statistical analysis of the digital radiographic grey values. The charts produced were for stainless steel and aluminum. According to EN 14784-2:2005, acceptable normalized signal-to-noise ratio (SNR N ) for testing class A and class B shall have minimum 70 and 120 respectively. (author)

  11. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.

    Science.gov (United States)

    Choo, Ji Yung; Lee, Ki Yeol; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Choi, Jung Won; Kang, Eun-Young; Oh, Yu Whan

    2016-09-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. • Digital tomosynthesis offers new diagnostic options for airway lesions. • Digital tomosynthesis is more sensitive and accurate than radiography for airway lesions. • Digital tomosynthesis shows better image quality than radiography. • Assessment of lesion severity, via tomosynthesis is comparable to computed tomography.

  12. Radiography and bone scintigraphy in bone marrow transplant multiple myeloma patients

    International Nuclear Information System (INIS)

    Aagren, B.; Aspelin, P.

    1997-01-01

    Purpose: To compare conventional radiography and bone scintigraphy in relation to clinical outcome in bone marrow transplant multiple myeloma patients. Material and Methods: A total of 70 radiographies and 70 bone scintigraphies were compared in 35 patients. Results: The skull, the extremities, the iliac and public bones were better assessed with radiography. For new vertebral lesions and for lesions in the ribs and sternum, bone scintigraphy proved superior. For the sacrum, the methods were equal. When bone scintigraphy was used as a complement to radiography, 4% more pathological sites were found. No patient had both a normal radiography and a pathological bone scintigraphy, but 5 patients had both a normal bone scintigraphy and a pathological radiography. The results of the radiological examinations did not always correlate with the clinician's grading of the patient's disease. The radiological examinations had no prognostic value for the 7 patients examined on several occasions. Conclusion: The ability of conventional radiography and bone scintigraphy to disclose myeloma lesions varies, depending on location and size of the lesions. Radiography should remain the primary examination modality also for bone marrow transplant multiple myeloma patients. Bone scintigraphy can severe as a complement for investigating unexplained pain, e.g. caused by lesions in vertebrae or ribs. (orig.)

  13. The MU-RAY project: Volcano radiography with cosmic-ray muons

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosi, G. [INFN sezione di Perugia (Italy); Ambrosino, F. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Battiston, R. [INFN sezione di Perugia (Italy); Universita di Perugia (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Cassese, F. [INFN sezione di Napoli (Italy); Castellini, G. [CNR-IFAC, Firenze (Italy); Ciaranfi, R. [INFN sezione Firenze (Italy); Cozzolino, F. [INFN sezione di Napoli (Italy); D' Alessandro, R. [INFN sezione Firenze (Italy); Universita di Firenze (Italy); La Taille, C. de [LAL, Orsay (France); Iacobucci, G. [INFN sezione di Napoli (Italy); Marotta, A. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Masone, V. [INFN sezione di Napoli (Italy); Martini, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Nishiyama, R. [Earthquake Research Institute, The University of Tokyo (Japan); Noli, P. [INFN sezione di Napoli (Italy); Universita Federico II, Napoli (Italy); Orazi, M. [INGV-Osservatorio Vesuviano, Napoli (Italy); Parascandolo, L.; Parascandolo, P. [INFN sezione di Napoli (Italy)

    2011-02-01

    Cosmic-ray muon radiography is a technique for imaging the variation of density inside the top few 100 m of a volcanic cone. With resolutions up to 10s of meters in optimal detection conditions, muon radiography can provide images of the top region of a volcano edifice with a resolution that is considerably better than that typically achieved with conventional methods. Such precise measurements are expected to provide us with information on anomalies in the rock density distribution, like those expected from dense lava conduits, low density magma supply paths or the compression with depth of the overlying soil. The MU-RAY project aims at the construction of muon telescopes and the development of new analysis tools for muon radiography. The telescopes are required to be able to work in harsh environment and to have low power consumption, good angular and time resolutions, large active area and modularity. The telescope consists of two X-Y planes of 2x2 square meters area made by plastic scintillator strips of triangular shape. Each strip is read by a fast WLS fiber coupled to a silicon photomultiplier. The readout electronics is based on the SPIROC chip.

  14. Simulation of the radiography formation process from CT patient volume

    International Nuclear Information System (INIS)

    Bifulco, P.; Cesarelli, M.; Verso, E.; Roccasalva Firenze, M.; Sansone, M.; Bracale, M.

    1998-01-01

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors)

  15. Digital image intensifier radiography. One year's experience with a Polytron system

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.; Georgi, M.

    1989-01-01

    Since January 1988, digital image intensifier radiography has been used in the Clinic in Mannheim for DSA examinations and also in place of conventional screen/film examinations. Measurements have shown that compared with 100 mm and film/screen formats, digital radiography has poorer spatial resolution, but improved contrast resolution. The most common use of digital radiography was for examinations of the gastrointestinal tract. Using the demonstration of the mucosal fine relief pattern as a criterion of image quality, digital image intensifier radiography was able to achieve this satisfactorily. Comparison with film/screen examinations showed no loss of diagnostic information. Advantages of image intensifier radiography are reduced radiation dose, the possibility of postprocessing and economy. On the basis of 399 examinations, digital image intensifier radiography is now firmly established as part of the daily routine of the Mannheim Clinic. (orig.) [de

  16. Ambulating radiography

    International Nuclear Information System (INIS)

    Magnusson, K.

    1989-01-01

    Strong gamme or X-ray sources are utilized for non-destructive testing of i.e. bridges. The activities involve certain risks of accident that might lead to serious injuries caused by radiation. The National Institute of Radiation Protection has during the laste decade greatly yhe inspection rate in this area. It has today made controls of most enterprieses running ambulating radiography. (O.S.)

  17. Evaluation of occupational exposure in intraoral radiography

    International Nuclear Information System (INIS)

    Miguel, Cristiano; Barros, Frieda S.; Rocha, Anna S.P.S.; Godoi, Walmor C.; Tilly Junior, Joao G.

    2014-01-01

    The intraoral radiography is widely performed in the dental office due to low cost and agility. The doses in intraoral radiology are considered low, however it is known that doses below the threshold for deterministic radiation has the potential to induce stochastic effects. An intraoral radiography has a risk of inducing fatal cancer or serious in order of 1:10,000,000. Besides the patient, the dentist may also be being exposed to radiation during the work with the radiographics practices. The bibliographies demonstrates the lack of information on radiation protection of dentists, however, the occupational dose reduction was observed in radiology over the past 14 years. This work aims to evaluate the effective dose of radiation to which workers can be exposed dentists in dental offices to perform intraoral radiographs. In this context, a study was be conducted between June 2013 and May 2014 with 44 professionals in Curitiba city. For each dentist was given a personal dosimeter to be used for 30 days. During this period, the number of radiographies and the length of the cable triggers of the X-ray equipment was registered and, the dosimeter´s dose was read. It was observed that the cables triggers meet regulatory standards and allow dentists to get the mean minimum distance of two meters from the radiation source in 93% of cases. Through analysis of the doses, it was concluded that occupational exposures of these workers are within the recommended threshold by regulatory 453/1998 of the Ministry of Health from Brazil. (author)

  18. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  19. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio; Abe, Takayuki; Ogawa, Kenji

    2013-01-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA -950 ) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950 . The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA -950 . (orig.)

  20. Development of techniques for furthering the use of isotope radiography

    International Nuclear Information System (INIS)

    Wamorkar, R.R.; Singh, G.; Kalurkar, A.R.; Jagasia, N.S.; Malhotra, H.K.

    1977-01-01

    Isotope radiography techniques in the non-conventional applications such as : (a) hot radiography - a method for examination of radioactive materials, and (b) thin section radiography for inspection of biological specimen and non-metallic specimen are described. Also, a process used for the reproduction of gamma-graphs of welds and castings has been discussed in detail. (author)

  1. Use of radiography in archaeology

    International Nuclear Information System (INIS)

    Chetin, M.; Ekinci, Sh.; Aksu, M.

    2014-01-01

    Full text : Radiography is a versatile technique with many applications to archaeological and art historical artefacts. It can be used to assess the condition of objects before conservation treatment, to gain insight into materials used and methods of construction and to reveal the secrets of the embalmers art, hidden within mummified remains. X-ray radiography is an invaluable investigative technique that is non-destructive, quick and cost effective. The study described below covers the investigations of the archaeological artefacts in order to determine their corrosion conditions and production histories which are important for restoration, conservation, replica, dating and inventory works

  2. Nuclear track radiography of 'hot' aerosol particles

    CERN Document Server

    Boulyga, S F; Kievets, M K; Lomonosova, E M; Zhuk, I V; Yaroshevich, O I; Perelygin, V P; Petrova, R I; Brandt, R; Vater, P

    1999-01-01

    Nuclear track radiography was applied to identify aerosol 'hot' particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the alpha-activity of 'hot' particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and (gamma,f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of 'hot' particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by sup 2 sup 3 sup 5 U, sup 2 sup 3 sup 9 Pu and sup 2 sup 4 sup 1 Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5x10 sup - sup 6 Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical imag...

  3. Nuclear track radiography of 'hot' aerosol particles

    International Nuclear Information System (INIS)

    Boulyga, S.F.; Kievitskaja, A.I.; Kievets, M.K.; Lomonosova, E.M.; Zhuk, I.V.; Yaroshevich, O.I.; Perelygin, V.P.; Petrova, R.; Brandt, R.; Vater, P.

    1999-01-01

    Nuclear track radiography was applied to identify aerosol 'hot' particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the α-activity of 'hot' particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and (γ,f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of 'hot' particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by 235 U, 239 Pu and 241 Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5x10 -6 Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical image of the SSNTD surface obtained through a video camera and the determination of size and activity of 'hot' particles

  4. Physical Violence between Siblings: A Theoretical and Empirical Analysis

    Science.gov (United States)

    Hoffman, Kristi L.; Kiecolt, K. Jill; Edwards, John N.

    2005-01-01

    This study develops and tests a theoretical model to explain sibling violence based on the feminist, conflict, and social learning theoretical perspectives and research in psychology and sociology. A multivariate analysis of data from 651 young adults generally supports hypotheses from all three theoretical perspectives. Males with brothers have…

  5. A probabilistic risk assessment for field radiography based on expert judgment and opinion

    International Nuclear Information System (INIS)

    Jang, Han-Ki; Ryu, Hyung-Joon; Kim, Ji-Young; Lee, Jai-Ki; Cho, Kun-Woo

    2011-01-01

    A probabilistic approach was applied to assess radiation risk associated with the field radiography using gamma sources. The Delphi method based on the expert judgments and opinions was used in the process of characterization of parameters affecting risk, which are inevitably subject to large uncertainties. A mathematical approach applying the Bayesian inferences was employed for data processing to improve the Delphi results. This process consists of three phases: (1) setting prior distributions, (2) constructing the likelihood functions and (3) deriving the posterior distributions based on the likelihood functions. The approach for characterizing input parameters using the Bayesian inference is provided for improved risk estimates without intentional rejection of part of the data, which demonstrated utility of Bayesian updating of distributions of uncertain input parameters in PRA (Probabilistic Risk Assessment). The data analysis portion for PRA in field radiography is addressed for estimates of the parameters used to determine the frequencies and consequences of the various events modeled. In this study, radiological risks for the worker and the public member in the vicinity of the work place are estimated for field radiography system in Korea based on two-dimensional Monte Carlo Analysis (2D MCA). (author)

  6. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  7. Quality comparison of direct digital panoramic radiography and computed radiography panoramic

    Directory of Open Access Journals (Sweden)

    Dariush Goodarzipour

    2013-09-01

    Full Text Available BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels. The first category is defined as computed radiography (CR or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR. Both of these technologies have their own advantages and disadvantages. One of the most important fields in comparison of these systems is their resultant image quality. The purpose of this study was to compare the subjective image quality of DDR and CR digital panoramic system, and to assess the overall density and contrast of their images. METHODS: 200 patients were randomly allocated to two digital systems: Promax [central control digital (CCD] and XC [photostimulable phosphor plates (PSP]. Image quality was evaluated in six regions on a 3-point scale by three oral and maxillofacial radiologists independently. In addition, observers assessed overall density and contrast of each image on a 3-point scale. RESULTS: Using chi-square test, no statistically significant differences were found (P >0.05 in subjective image quality of anatomic structures between the two radiographic systems. But DDR system outperformed CR system in overall density and contrast of the image. P values for both overall density and contrast of the images was less than 0.001. CONCLUSIONS: The subjective image quality of CR and DDR panoramic systems in specified anatomic regions were found statistically comparable in this study. In overall density and contrast of the radiographs, DDR system proved better than CR system.

  8. Radiography of the chest and upper airway

    International Nuclear Information System (INIS)

    Sharko, G.A.; Wilmot, D.M.

    1987-01-01

    The techniques of radiography of the chest in all pediatric-age groups differ only slightly from those used in adult radiography. The technologist's principal challenge, however, relates to optimum handling of the patient with respect to positioning and radiation protection. The hints provided in this chapter should permit the conscientious radiographer to obtain high quality radiographs on all pediatric patients

  9. Radiological protection in equine radiography and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoxall, A.T.

    1977-10-01

    The principles of radiological protection are summarised and consideration is then given to problems, which may confront the equine practitioner, in the fulfillment of these principles during diagnostic radiography of the limbs, head, and spine of the horse. The place of anaesthesia in such procedures is discussed and the special problems associated with therapeutic radiography of the horse are considered.

  10. Evaluation of a Noise Reduction Procedure for Chest Radiography

    Science.gov (United States)

    Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi

    2013-01-01

    Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577

  11. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  12. Establishing rigour in qualitative radiography research

    International Nuclear Information System (INIS)

    Murphy, F.J.; Yielder, J.

    2010-01-01

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  13. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  14. Learning Styles of Radiography Students during Clinical Practice

    Science.gov (United States)

    Ward, L. Patrice

    2009-01-01

    The purpose of this study was to identify and describe the common learning styles of radiography students during clinical practice. Quantitative, descriptive research methodology identified the learning styles of radiography students. A single self-report questionnaire, developed to assess learning styles in clinical practice, was administered…

  15. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  16. Common positioning errors in panoramic radiography: A review

    International Nuclear Information System (INIS)

    Randon, Rafael Henrique Nunes; Pereira, Yamba Carla Lara; Nascimento, Glauce Crivelaro do

    2014-01-01

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  17. Neutron radiography at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pleinert, H.; Lehmann, E.; Hammer, J.

    1994-01-01

    Neutron radiography provides an efficient tool of measurement for many applications in fundamental research as well as in industrial non-destructive testing (NDT). A neutron radiography program has been initiated at the Paul Scherrer Institute and implemented since 1992. From the beginning of 1992 until the end of 1993, a neutron facility has been in operation at the SAPHIR research reactor. Several applications have been tested and programs on two main fields of application have been established, focusing on the study of porous materials, especially concrete and granitic rock. The investigations on concrete and other building materials are carried out in cooperation with the Swiss Federal Institute of Technology in Zurich. The experimental activities are currently carried out at the Atominstitute of the Austrian Universities in Vienna, in the framework of a cooperation program with the Atominstitute. The continuation of the activities on a new radiography facility at the spallation source SINQ is planned at the Paul Scherrer Institute. In the following an overview of the method, of the actual and potential applications of neutron radiography at the Paul Scherrer Institute is given. (author) 6 figs., 1 tab., 3 refs

  18. Relationship Between the Number of Clinical Sites in Radiography Programs and Job Placement Rates of Graduates.

    Science.gov (United States)

    Harrell, Angela; Matthews, Eric

    2016-07-01

    To determine whether a relationship exists between the number of clinical sites available in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology and the job placement rates of graduates. We performed a secondary analysis of data on job placement rates and the number of clinical sites available in 438 degree-granting radiography programs from January 2015 to March 2015. A weak, negative, nonsignificant correlation existed between the number of clinical sites and the job placement rate (Spearman's rho = -.113, n = 438, P = .018). The coefficient of determination was 1.28%.Discussion Research evaluating factors contributing to graduate employability is limited but indicates no need for radiography program administrators to adjust clinical site numbers solely on the basis of improving graduate employability. The number of clinical sites available in a radiography program is not related to the job placement rate of its graduates. ©2016 American Society of Radiologic Technologists.

  19. Skin entrance dose for digital and film radiography in Korean dental schools

    International Nuclear Information System (INIS)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol

    2005-01-01

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 μGy for digital radiography and 1,205.0 μGy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  20. Skin entrance dose for digital and film radiography in Korean dental schools

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Eun Sang; Choi, Kun Ho; Kim, Min Gyu; Lim, Hoi Jeong; Yoon, Suk Ja; Kang, Byung Cheol [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    2005-12-15

    This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician at each school to set the exposure parameters and aiming the x-ray tube for the peri apical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter; Unifors instruments, Billdal, Sweden). The median dose was 491.2 {mu}Gy for digital radiography and 1,205.0 {mu}Gy for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Fifty-nine percent skin entrance dose reduction with digital peri apical radiography was achieved over the film radiography in Korean dental schools.

  1. Algorithm for optimisation of paediatric chest radiography

    International Nuclear Information System (INIS)

    Kostova-Lefterova, D.

    2016-01-01

    The purpose of this work is to assess the current practice and patient doses in paediatric chest radiography in a large university hospital. The X-ray unit is used in the paediatric department for respiratory diseases. Another purpose was to recommend and apply optimized protocols to reduce patient dose while maintaining diagnostic image quality for the x-ray images. The practice of two different radiographers was studied. The results were compared with the existing practice in paediatric chest radiography and the opportunities for optimization were identified in order to reduce patient doses. A methodology was developed for optimization of the x-ray examinations by grouping children in age groups or according to other appropriate indication and creating an algorithm for proper selection of the exposure parameters for each group. The algorithm for the optimisation of paediatric chest radiography reduced patient doses (PKA, organ dose, effective dose) between 1.5 and 6 times for the different age groups, the average glandular dose up to 10 times and the dose for the lung between 2 and 5 times. The resulting X-ray images were of good diagnostic quality. The subjectivity in the choice of exposure parameters was reduced and standardization has been achieved in the work of the radiographers. The role of the radiologist, the medical physicist and radiographer in the process of optimization was shown. It was proven the effect of teamwork in reducing patient doses at keeping adequate image quality. Key words: Chest Radiography. Paediatric Radiography. Optimization. Radiation Exposure. Radiation Protection

  2. Radiation protection and safety in industrial radiography

    International Nuclear Information System (INIS)

    1999-01-01

    The use of ionizing radiation, particularly in medicine and industry, is growing throughout the world, with further expansion likely as technical developments result from research. One of the longest established applications of ionizing radiation is industrial radiography, which uses both X radiation and gamma radiation to investigate the integrity of equipment and structures. Industrial radiography is widespread in almost all Member States. It is indispensable to the quality assurance required in modern engineering practice and features in the work of multinational companies and small businesses alike. Industrial radiography is extremely versatile. The equipment required is relatively inexpensive and simple to operate. It may be highly portable and capable of being operated by a single worker in a wide range of different conditions, such as at remote construction sites, offshore locations and cross-country pipelines as well as in complex fabrication facilities. The associated hazards demand that safe working practices be developed in order to minimize the potential exposure of radiographers and other persons who may be in the vicinity of the work. The use of shielded enclosures (fixed facilities), with effective safety devices, significantly reduces any radiation exposures arising from the work. This Safety Report summarizes good and current state of the art practices in industrial radiography and provides technical advice on radiation protection and safety. It contains information for Regulatory Authorities, operating organizations, workers, equipment manufacturers and client organizations, with the intention of explaining their responsibilities and means to enhance radiation protection and safety in industrial radiography

  3. Basic research for developing the quantitative neutron radiography

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Ikeda, Yasushi; Ohkubo, Kohei; Tasaka, Kanji; Yoneda, Kenji; Fujine, Shigenori.

    1992-01-01

    This investigation concerns the basic research and development on quantitative neutron radiography by using a honeycomb collimator which reduces the effect due to scattered neutrons in objective matter. On the observation of the hydrogenate materials such as metal hydrides, water and hydrocarbons by neutron radiography, scattered neutrons from these objectives make the quantitativeness of the neutron radiographic image lower grade. In order to improve the quantitativeness of the image, a honeycomb collimator, which is a honeycomb structure of neutron absorbing material, was introduced to the conventional neutron radiography system. By setting the neutron-absorbing honeycomb collimator between objective and imaging system, neutrons scattered in the objective were absorbed by the honeycomb material and attenuated before coming to the imaging system, but neutrons which were transmitted the objective sample without any interaction reached the imaging system and formed the image of the sample. As the image by purely transmitted neutrons is intrinsic due to the neutronic character of the sample, the image data give the quantitative information. In the present experiment, aluminum honeycomb which was coated with boron nitride was prepared and used in order to image the standard stepwise samples for the evaluation of the quantitative grade of the newly proposed neutron radiography method. From the comparison between macroscopic total cross section and the attenuation coefficient of the thermal neutron for aluminum, copper and hydrocarbons, it was confirmed that they were fairly consistent each other. It can be concluded that the newly proposed neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improves remarkably the quantitativeness of the neutron radiography technique. (author)

  4. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  5. Apparatus for proton radiography

    International Nuclear Information System (INIS)

    Martin, R.L.

    1976-01-01

    An apparatus for effecting diagnostic proton radiography of patients in hospitals comprises a source of negative hydrogen ions, a synchrotron for accelerating the negative hydrogen ions to a predetermined energy, a plurality of stations for stripping extraction of a radiography beam of protons, means for sweeping the extracted beam to cover a target, and means for measuring the residual range, residual energy, or percentage transmission of protons that pass through the target. The combination of information identifying the position of the beam with information about particles traversing the subject and the back absorber is performed with the aid of a computer to provide a proton radiograph of the subject. In an alternate embodiment of the invention, a back absorber comprises a plurality of scintillators which are coupled to detectors. 10 claims, 7 drawing figures

  6. Clinical evaluation of digital radiography based on a large-area cesium iodide-amorphous silicon flat-panel detector compared with screen-film radiography for skeletal system and abdomen

    International Nuclear Information System (INIS)

    Okamura, Terue; Tanaka, Saori; Koyama, Koichi; Norihumi, Nishida; Daikokuya, Hideo; Matsuoka, Toshiyuki; Yamada, Ryusaku; Kishimoto, Kenji; Hatagawa, Masakatsu; Kudoh, Hiroaki

    2002-01-01

    The aim of this clinical study was to compare the image quality of digital radiography using the new digital Bucky system based on a flat-panel detector with that of a conventional screen-film system for the skeletal structure and the abdomen. Fifty patients were examined using digital radiography with a flat-panel detector and screen-film systems, 25 for the skeletal structures and 25 for the abdomen. Six radiologists judged each paired image acquired under the same exposure parameters concerning three observation items for the bone and six items for the abdomen. Digital radiographic images for the bone were evaluated to be similar to screen-film images at the mean of 42.2%, to be superior at 50.2%, and to be inferior at 7.6%. Digital radiographic images for the abdomen were judged to be similar to screen-film images at the mean of 43.4%, superior at 52.4%, and inferior at 4.2%; thus, digital radiographic images were estimated to be either similar as or superior to screen-film images at over 92% for the bone and abdomen. On the statistical analysis, digital radiographic images were also judged to be preferred significantly in the most items for the bone and abdomen. In conclusion, the image quality of digital radiography with a flat-panel detector was superior to that of a screen-film system under the same exposure parameters, suggesting that dose reduction is possible with digital radiography. (orig.)

  7. Liquid metal flow measurement by neutron radiography

    International Nuclear Information System (INIS)

    Takenaka, N.; Ono, A.; Matsubayashi, M.; Tsuruno, A.

    1996-01-01

    Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd 3 ) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.)

  8. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup [Radiation Safety Division National Institute of Food and Drug Safety Evaluation, Seoul (Korea, Republic of)

    2009-12-15

    Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60-97 kVp, with the average use being 75 kVp, and the tube current ranged between 8-123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65-100 kVp (average use: 78 kVp) and 70-109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10-100 mAs(average use: 35 mAs) and between 8.9-300 mAs(average use: 64 mAs), respectively. The measurements of

  9. Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea

    International Nuclear Information System (INIS)

    Lee, Kwang Yong; Lee, Byung Young; Lee, Jung Eun; Lee, Hyun Koo; Jung, Seunbg Hwan; Kim, Byung Woo; Kim, Hyeog Ju; Kim, Dong Sup

    2009-01-01

    Pelvis and lumbar spine radiography, among various types of diagnostic radiography, include gonads of the human body and give patients high radiation dose. Nevertheless, diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography has not yet been established in Korea. Therefore, the radiation dose that patients receive from pelvis and lumbar radiography is measured and the diagnostic reference level on patient radiation dose for the optimization of radiation protection of patients in pelvis and lumbar spine radiography was established. The conditions and diagnostic imaging information acquired during the time of the postero-anterior view of the pelvis and the postero-anterior and lateral view of the lumbar spine at 125 medical institutions throughout Korea are collected for analysis and the entrance surface dose received by patients is measured using a glass dosimeter. The diagnostic reference levels for patient radiation dose in pelvis and lumbar spine radiography to be recommended to the medical institutes is arranged by establishing the dose from the patient radiation dose that corresponds to the 3rd quartile values as the appropriate diagnostic reference level for patient radiation dose. According to the results of the assessment of diagnostic imaging information acquired from pelvis and lumbar spine radiography and the measurement of patient entrance surface dose taken at the 125 medical institutes throughout Korea, the tube voltage ranged between 60-97 kVp, with the average use being 75 kVp, and the tube current ranged between 8-123 mAs, with the average use being 30 mAs. In the posteroanterior and lateral views of lumbar spine radiography, the tube voltage of each view ranged between 65-100 kVp (average use: 78 kVp) and 70-109 kVp (average use: 87 kVp), respectively, and the tube current of each view ranged between 10-100 mAs(average use: 35 mAs) and between 8.9-300 mAs(average use: 64 mAs), respectively. The measurements of

  10. Theoretical analysis of polarized structure functions

    International Nuclear Information System (INIS)

    Altarelli, G.; ); Ball, R.D.; Forte, S.; Ridolfi, G.

    1998-01-01

    We review the analysis of polarized structure function data using perturbative QCD and NLO We use the most recent experimental data to obtain updated results for polarized parton distributions, first moments and the strong coupling. We also discuss several theoretical issues involving in this analysis and in the interpretation of its results. Finally, we compare our results with other similar analyses in the recent literature. (author)

  11. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  12. Digital Radiography of a Drop Tested 9975 Radioactive Materials Packaging

    International Nuclear Information System (INIS)

    Blanton, P.S.

    2001-01-01

    This paper discusses the use of radiography as a tool for evaluating damage to radioactive material packaging subjected to regulatory accident conditions. The Code of Federal Regulations, 10 CFR 71, presents the performance based requirements that must be used in the development (design, fabrication and testing) of a radioactive material packaging. The use of various non-destructive examination techniques in the fabrication of packages is common. One such technique is the use of conventional radiography in the examination of welds. Radiography is conventional in the sense that images are caught one at a time on film stock. Most recently, digital radiography has been used to characterize internal damage to a package subjected to the 30-foot hypothetical accident conditions (HAC) drop. Digital radiography allows for real time evaluation of the item being inspected. This paper presents a summary discussion of the digital radiographic technique and an example of radiographic results of a 9975 package following the HAC 30-foot drop

  13. Non-destructive evaluation utilizing imaging plates for field radiography applications

    International Nuclear Information System (INIS)

    White, Brian S.

    2016-01-01

    The oil and gas industry has utilized film radiography for the evaluation of pipeline welds for many years. The world has evolved, and today people are easily sharing digital images as part of the information revolution. Computed radiography is ready to replace film radiography for portable outdoor use applications. Computed radiography technology adoption has been contingent upon achieving acceptable image quality and getting enough imaging plate use cycles to be profitable. Image quality is dependent upon shot conditions, imaging plate type, reader settings, and scatter control. Likewise, the number of achievable use cycles is dependent upon the imaging plate design for durability and the user's operating environment. This presentation reviews the basic principles of storage phosphor imaging plates. Usage criteria and guidelines for optimum image quality and maximized overall use cycles will be discussed for various imaging plate types. A comparison of film and computed radiography imaging plate technology will be presented.

  14. Report based on fiscal 2000 diagnostic X-ray equipment questionnaire survey. Conditions of radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, Mitsuo [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Allied Health Sciences; Matsuura, Takatoshi [Sekishinkai Sayama Hospital, Saitama (Japan); Okuaki, Tomoyuki; Imai, Yoshio; Tsukamoto, Atsuko [Kanto Medical Center NTT EC, Tokyo (Japan); Ide, Toshinori [Kajima Corp., Tokyo (Japan). Kajima Clinic; Shinohara, Fuminori [Nippon Medical School, Kawasaki, Kanagawa (Japan). Second Hospital; Miyazaki, Shigeru [Toho Univ., Tokyo (Japan). Ohashi Hospital

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film (SEF) in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations. (author)

  15. [Report based on fiscal 2000 diagnostic x-ray equipment questionnaire survey(conditions of radiography)].

    Science.gov (United States)

    Ishikawa, Mitsuo; Matsuura, Takatoshi; Okuaki, Tomiyuki; Imai, Yoshio; Tsukamoto, Atsuko; Ide, Toshinori; Shinohara, Fuminori; Miyazaki, Shigeru

    2002-08-01

    X-ray equipment has seen advances in inverters and the digitalization of reception systems. The X-ray Systems Study Group, in order to examine changes in the conditions of radiography, including pediatric radiography, variations in shortest irradiation time, and standardization of the conditions of radiography, carried out investigative research using a questionnaire survey that was sent to 400 facilities. The recovery rate was 33%. In terms of the reception system, half of the general radiography systems were using computed radiography (CR). Seventy percent of respondents used an intensifying screen and film(S EF)in stomach double-contrast radiography. About 80% used digital radiography (DR) and digital subtraction angiography (DSA) in aorta abdominalis angiography. At least 70% of high-voltage generators were of the inverter type. The conditions of radiography were not greatly influenced by changes in reception systems and X-ray equipment. Many pediatric radiographies were carried out by radiological technologists. We consider it useful to conduct such survey investigations.

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  17. Flash x-radiography for material motion detection

    International Nuclear Information System (INIS)

    Choate, L.M.; Buckalew, W.H.; Posey, L.D.

    1977-01-01

    A significant part of the experimental program dealing with the behavior of prototypic LMFBR fuel pin bundles under mild to severe power transients is that of the observation of fuel/cladding/coolant motion. The feasibility of using electron beam flash x-radiography as a diagnostic tool for safety test facilities is presently under evaluation. A summary of the objectives and approach of the flash x-radiography program is presented

  18. Radiological incidents in industrial gamma radiography in the Philippines, 1979-1993

    International Nuclear Information System (INIS)

    Borras, A.M.

    1994-01-01

    Among the many practices of radiation sources, the practice of industrial gamma radiography in the country has the most number of reported radiological incidents. During the past fourteen (14) years, from 1979-1993, twenty (20) incidents that have occurred were reported to the Institute. This paper presents the nature and extent of the 20 reported incidents as well as the results of the analysis of why these incidents happened. The results of the analysis showed that the causes of these incidents are mainly human error and equipment failure. Hence, the factors that can minimize or prevent the chance of occurrence and/or recurrence of incidents and in minimizing the hazard in case of radiological incidents are: a) proper training and re-training of personnel; b) proper and regular inspection and maintenance of equipment; c) adequate radiation survey; and d) proper storage and inventory of the radiography sealed sources. (author). 3 refs.; 5 figs.; 1 tab

  19. Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography

    Science.gov (United States)

    Tsuchiya, Yoshinori; Matsubayashi, Masahito; Takeda, Tohoru; Lwin, Thet Thet; Wu, Jin; Yoneyama, Akio; Matsumura, Akira; Hori, Tomiei; Itai, Yuji

    2003-11-01

    Neutron radiography is based on differences in neutron mass attenuation coefficients among the elements and is a non-destructive imaging method. To investigate biomedical applications of neutron radiography, imaging of rabbit VX-2 liver cancer was performed using thermal and cold neutron radiography with a neutron imaging plate. Hepatic vessels and VX-2 tumor were clearly observed by neutron radiography, especially by cold neutron imaging. The image contrast of this modality was better than that of absorption-contrast X-ray radiography.

  20. Radiography Student Participation in Professional Organizations.

    Science.gov (United States)

    Michael, Kimberly; Tran, Xuan; Keller, Shelby; Sayles, Harlan; Custer, Tanya

    2017-09-01

    To gather data on educational program requirements for student membership in a state or national professional society, organization, or association. A 10-question online survey about student involvement in professional societies was emailed to 616 directors of Joint Review Committee on Education in Radiologic Technology (JRCERT)-accredited radiography programs. A total of 219 responses were received, for a 36% response rate. Of these, 89 respondents (41%) answered that their programs require students to join a professional organization. The society respondents most often required (70%) was a state radiography society. Sixty respondents (68%) answered that students join a society at the beginning of the radiography program (from matriculation to 3 months in). Of programs requiring student membership in professional societies, 42 (49%) reported that their students attend the state or national society annual conference; however, participation in activities at the conferences and in the society throughout the year is lower than conference attendance. Some directors stated that although their programs' policies do not allow membership mandates, they encourage students to become members, primarily so that they can access webinars and other educational materials or information related to the profession. Survey data showed that most JRCERT-accredited radiography programs support but do not require student membership in professional organizations. The data reveal that more programs have added those requirements in recent years. Increased student participation could be realized if programs mandated membership and supported it financially. ©2017 American Society of Radiologic Technologists.

  1. Simulation of the radiography formation process from CT patient volume

    Energy Technology Data Exchange (ETDEWEB)

    Bifulco, P; Cesarelli, M; Verso, E; Roccasalva Firenze, M; Sansone, M; Bracale, M [University of Naples, Federico II, Electronic Engineering Department, Bioengineering Unit, Via Claudio, 21 - 80125 Naples (Italy)

    1999-12-31

    The aim of this work is to develop an algorithm to simulate the radiographic image formation process using volumetric anatomical data of the patient, obtained from 3D diagnostic CT images. Many applications, including radiographic driven surgery, virtual reality in medicine and radiologist teaching and training, may take advantage of such technique. The designed algorithm has been developed to simulate a generic radiographic equipment, whatever oriented respect to the patient. The simulated radiography is obtained considering a discrete number of X-ray paths departing from the focus, passing through the patient volume and reaching the radiographic plane. To evaluate a generic pixel of the simulated radiography, the cumulative absorption along the corresponding X-ray is computed. To estimate X-ray absorption in a generic point of the patient volume, 3D interpolation of CT data has been adopted. The proposed technique is quite similar to those employed in Ray Tracing. A computer designed test volume has been used to assess the reliability of the radiography simulation algorithm as a measuring tool. From the errors analysis emerges that the accuracy achieved by the radiographic simulation algorithm is largely confined within the sampling step of the CT volume. (authors) 16 refs., 12 figs., 1 tabs.

  2. The use of radiography for thickness measurement and corrosion monitoring in pipes

    International Nuclear Information System (INIS)

    Edalati, K.; Rastkhah, N.; Kermani, A.; Seiedi, M.; Movafeghi, A.

    2006-01-01

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques

  3. The use of radiography for thickness measurement and corrosion monitoring in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Edalati, K. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)]. E-mail: NDT99@aeoi.org.ir; Rastkhah, N. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Kermani, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Seiedi, M. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of); Movafeghi, A. [Department of NDT, Nuclear Safety and Radiation Protection Technological Centre, AEOI, P.O. Box 14155-1399, Tehran (Iran, Islamic Republic of)

    2006-10-15

    In this study of pipes of 150 mm diameters, thickness ranging from 4.2 to 15.0 mm was determined by using two radiography techniques: tangential radiography and double wall radiography. It was concluded that thickness losses of 10%, 20% and 50% could be determined by these methods. Formulae were developed for the double wall radiography method with a high precision of thickness measurement for non-insulated pipes. The precision was comparable with ultrasonic measurement results. Corrosion type and corrosion surface could be observed by these methods. Internal or external corrosion produced different effects in tangential radiography. Insulation removal was not necessary using the radiographic techniques.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Radiography) - Bone Bone x-ray uses a very small dose of ionizing radiation to produce pictures of ... exposing a part of the body to a small dose of ionizing radiation to produce pictures of ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  6. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  7. A study on the scattered dose in portable chest radiography

    International Nuclear Information System (INIS)

    Ahn, Bong Seon; Lee, Hwan Hyung

    2000-01-01

    The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. The average of distance of adjacent patients was 219.1 cm at the ward. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it dose not have influence on the adjacent patient. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment

  8. Compton radiography, 2

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Sera, Koichiro; Fukuda, Hiroshi; Shishido, Fumio; Mishina, Hitoshi.

    1977-01-01

    Compton radiography, a tomographic technic with Compton-scattered rays of a monochromatic gamma ray beam, was feasible of tomographing a chest phantom. The result suggested that the technic could be extended to imaging of the lung and the surrounding structures of the chest wall, mediastinum and liver in Compton tomographic mode. (auth.)

  9. Neutron resonance radiography: Report of a workshop, Los Alamos, NM: July 27-29, 1987

    International Nuclear Information System (INIS)

    1988-07-01

    Neutron resonance radiography is a new technique with great potential for non-destructive analysis and testing. This technique has been under research and development in a number of major research laboratories for some time. Unlike thermal neutron radiography, which is primarily oriented towards imaging hydrogen and a number of other highly neutron-absorptive materials without necessarily distinguishing between them, neutron resonance radiography has the capability of uniquely identifying many kinds of chemical elements and their individual isotopes. It also has the potential for temperature imaging in materials containing heavy elements and for certain dynamic features such as stroboscopic imaging. Although neutron resonance radiography has not yet been taken up in a systematic way for technological applications, significant development of ideas and instrumentation at the research level has blossomed. There have also been major developments in the availability of powerful pulsed-neutron sources. In light of these developments, the Los Alamos Neutron Scattering Center sponsored a workshop with the general aims of reviewing scientific and technical progress, discussing and highlighting future developments, and stimulating interest in technological exploitation of the methods. In addition to the techniques and instrumentation required for the field, the applications of neutron resonance radiography in some of the following industrial and manufacturing areas were discussed: nuclear fuel assay; nuclear safeguards in general; aerospace development (aeroengine blade temperature, stroboscopic techniques); diagnostics; non-nuclear industry (especially metallurgy); temperature imaging; use of mobile pulsed-neutron sources; and practical use of major pulsed-neutron facilities

  10. Measurements in support of a neutron radiography facility for the SLOWPOKE-2 at RMC

    International Nuclear Information System (INIS)

    Lewis, W.J.; Andrews, W.S.; Bennett, L.G.I.; Beeley, P.A.; Royal Military Coll. of Canada, Kingston, ON

    1990-01-01

    The feasibility of using the small (20 kWh) SLOWPOKE-2 research reactor for neutron radiography has been investigated. Although designed primarily for neutron activation analysis (NAA) and radioisotope production, the SLOWPOKE-2 at RMC was installed with a thermal column of heavy water in a sector of the water gap between the beryllium reflector and the reactor container. The thermal-neutron flux in the reactor pool, just beyond the reactor container, has been measured to be a factor of 2.7 higher than in similar locations remote from the thermal column. Placed in this location was a prototype neutron radiography facility, consisting of a beam tube (or collimator), vertically tangential to the reactor core, and a beam stop. Once the feasibility of using a SLOWPOKE-2 for neutron radiography was demonstrated, subsequent investigations were carried out to optimize the quality of the obtainable radiographs. Both neutron radiographic and thermal-neutron flux measurements were undertaken to determine the optimum placement and arrangement of the beam tube. A Category III (as defined by the ASTM Standard E545-86) neutron radiography facility was obtained, although Category I or II were indicated as feasible. Based on this prototype design and experimentation, a permanent neutron radiography facility will be installed. The design calculations have been finalized, construction blueprints have been prepared, and work is proceeding with the construction, installation and commissioning of the facility. (orig.)

  11. Game Theoretic Analysis of Road Traffic Problems in Nigeria ...

    African Journals Online (AJOL)

    Game Theoretic Analysis of Road Traffic Problems in Nigeria. ... problems in Nigeria are analysed in the context of a social dilemma. Game theoretic models based on the famous ... AJOL African Journals Online. HOW TO USE AJOL.

  12. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    Energy Technology Data Exchange (ETDEWEB)

    Walstrom, Peter Lowell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garnett, Robert William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chapman, Catherine A. B [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, Harry Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Otoole, Joseph Alfred [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Barber, Ronald L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gomez, Tony Simon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-28

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

  13. Common positioning errors in panoramic radiography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Randon, Rafael Henrique Nunes [Stomathology and Oral Diagnostic Program, School of Dentistry of Sao Paulo, University of Sao Paulo, Sao Paulo (Brazil); Pereira, Yamba Carla Lara [Biology Dental Buco Graduate Program, School of Dentistry of Piracicaba, University of Campinas, Piracicaba (Brazil); Nascimento, Glauce Crivelaro do [Psychobiology Graduate Program, School of Philosophy, Science and Literature of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto (Brazil)

    2014-03-15

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  14. Digital radiography detectors - A technical overview: Part 1

    International Nuclear Information System (INIS)

    Lanca, Luis; Silva, Augusto

    2009-01-01

    During the last two decades screen-film (SF) systems have been replaced by digital X-ray systems. The advent of digital technologies brought a number of digital solutions based on different detector and readout technologies. Improvements in technology allowed the development of new digital technologies for projection radiography such as computed radiography (CR) and digital radiography (DR). The large number of scientific papers concerning digital X-ray systems that have been published over the last 25 years indicates the relevance of these technologies in healthcare. There are important differences among different detector technologies that may affect system performance and image quality for diagnostic purposes. Radiographers are expected to have an effective understanding of digital X-ray technologies and a high level of knowledge and awareness concerning the capabilities of these systems. Patient safety and reliable diagnostic information are intrinsically linked to these factors. In this review article - which is the first of two parts - a global overview of the digital radiography systems (both CR and DR) currently available for clinical practice is provided

  15. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  16. The Delphi technique in radiography education research

    International Nuclear Information System (INIS)

    John-Matthews, J.St.; Wallace, M.J.; Robinson, L.

    2017-01-01

    Objectives: To describe and review the Delphi technique as a tool for radiographers engaged in mixed-methods research whereby agreement is required on the proficiencies needed by educational programmes for pre- and post- registration radiographers. This is achieved through a description offering a brief history of the technique. Through a literature search, radiography education research using this technique is identified. A protocol for a research project using the technique is presented. Using this worked example, advantages and disadvantages of the method are explored including sampling of participants, sample size, number of rounds and methods of feedback. Key findings: There are limited examples of the use of the Delphi technique in radiography literature including considerations on how to select experts and panel size. Conclusion: The Delphi technique is a suitable method for establishing collective agreement in the design of radiography educational interventions. Additional research is needed to deepen this evidence-based knowledge. - Highlights: • The Delphi Technique is used to gain collective agreement in forecasting healthcare education priorities. • There is increase of the use of the technique in healthcare education literature. • There are some examples of the technique in radiography education research. • A worked example of this technique is provided to critically evaluate this tool.

  17. Pilot experimental study on continual spectrum thermal neutron in-line phase contrast radiography

    International Nuclear Information System (INIS)

    Tang Bin; Huo Heyong; Wu Yang

    2009-01-01

    The in-line phase contrast radiography is one of phase contrast imaging methods. The neutron in-line phase contrast is developed with X-rays phase contrast radiography. In the paper, the principle of in-line phase contrast is introduced briefly and the experimental result of thermal neutron in-line contrast at SPRR-300 is analysed. It shows that thermal neutron can be used as in-line phase contrast radiography and enhances the edge of some sample in radiography and complements the disadvantage of conventional neutron radiography. (authors)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  19. Neutron radiography in metallurgy

    International Nuclear Information System (INIS)

    Rant, J.; Ilic, R.

    1977-01-01

    The review surveys microneutronographic and neutron-induced autoradiographic techniques and their applications in metallurgy. A brief survey of applications of neutron radiography as a method of non-destructive testing to some macroscopic problems in metallurgy is included. (author)

  20. Dynamic neutron radiography of a combustion engine

    International Nuclear Information System (INIS)

    Brunner, J.; Hillenbach, A.; Schillinger, B.

    2004-01-01

    Dynamic neutron radiography is a non-destructive testing method, which made big steps in the last years. Depending on the neutron flux, the object and the detector a time resolution down to 50 ms is possible. In the case of repetitive processes the object can be synchronized with the detector and better statistics in the image can be obtained by adding radiographies of the same phase. By delaying the trigger signal a radiography movie can be composed with a time resolution down to 100 μs. A combustion engine is an ideal sample for the explained technique, because the motor block of metal is relatively easy to penetrate, while oil and fuel attenuate the thermal neutron beam much stronger. Various experiments were performed at ILL and PSI. Soon the tomography station ANTARES at FRM-II will be ready for measurements. (author)

  1. Theoretical Analysis of Polarized Structure Functions

    CERN Document Server

    Altarelli, Guido; Forte, Stefano; Ridolfi, G

    1998-01-01

    We review the analysis of polarized structure function data using perturbative QCD at next-to-leading order. We use the most recent experimental data to obtain updated results for polarized parton distributions, first moments and the strong coupling. We also discuss several theoretical issues involved in this analysis and in the interpretation of its results. Finally, we compare our results with other similar analyses in the recent literature.

  2. Inspection of CF188 composite flight control surfaces with neutron radiography

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Mullin, S.K.

    1996-01-01

    At the Royal Military College of Canada's SLOWPOKE-2 Facility, a neutron radiography facility has been designed and installed using a small (20kWth), pool-type research reactor called the SLOWPOKE-2 (Safe Low Power c(K)ritical Experiment) as the neutron source. Since then, the research has continued along two fronts: developing applications and improving the quality of the neutron beam. The most interesting applications investigated to date has been the inspection of various metal ceramic composites and the inspection of the composite flight control surfaces of some of the CF188 Hornet aircraft. As part of the determination of the integrity of the aircraft, it was decided to inspect an aircraft with the highest flight house using both X- and neutron radiography. The neutron radiography and, to a lesser extent, X-radiography inspections completed at McClellan AFB revealed 93 anomalies. After returning to Canada, the component with the greatest structural significance, namely the right hand rudder from the vertical stabilizer, was removed from the aircraft and put through a rigorous program of numerous NDT inspections, including X-radiography (film and real-time), eddy current, ultrasonics (through transmission and pitch-catch), infrared thermography, and neutron radiography. Therefore, of all the techniques investigated, only through transmission ultrasonics and neutron radiography were able to identify large areas of hydration. However, only neutron radiography could identify the small areas of moisture and hydration. Given the structural significance of the flight control surfaces in modern fighter aircraft, even the smallest amounts of hydration could potentially lead to catastrophic results

  3. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  4. Swelling behavior detection of irradiated U-10Zr alloy fuel using indirect neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yong; Huo, He-yong; Wu, Yang [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Li, Jiangbo [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Zhou, Wei; Guo, Hai-bing [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Li, Hang, E-mail: lihang32@gmail.com [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China); Cao, Chao; Yin, Wei; Wang, Sheng; Liu, Bin; Feng, Qi-jie; Tang, Bin [Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang (China); Key Laboratory of Neutron Physics, Chinese Academy of Engineering Physics, Mianyang (China)

    2016-11-21

    It is hopeful that fusion-fission hybrid energy system will become an effective approach to achieve long-term sustainable development of fission energy. U-10Zr alloy (which means the mass ratio of Zr is 10%) fuel is the key material of subcritical blanket for fusion-fission hybrid energy system which the irradiation performance need to be considered. Indirect neutron radiography is used to detect the irradiated U-10Zr alloy because of the high residual dose in this paper. Different burnup samples (0.1%, 0.3%, 0.5% and 0.7%) have been tested with a special indirect neutron radiography device at CMRR (China Mianyang Research Reactor). The resolution of the device is better than 50 µm and the quantitative analysis of swelling behaviors was carried out. The results show that the swelling behaviors relate well to burnup character which can be detected accurately by indirect neutron radiography.

  5. Search for adequate quality standards for neutron radiography of nuclear fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-01-01

    Unlike in other fields of industrial radiography, where standard methods and procedures are used to control the quality of the radiographic image, no such standard exists for neutron radiography of nuclear fuel. To fill that gap it was felt that standardization work ought to be started in that field, too. Accordingly in 1979 an Euratom Neutron Radiography Working Group was constituted, which initiated standardization work in the field of neutron radiography of nuclear fuel. Finding adequate standards for image quality of neutron radiographs and checking the accuracy of dimension measurements from them were given first priority. (Auth.)

  6. Industrial radiography X and Gamma

    International Nuclear Information System (INIS)

    Torres M, Nelson; Torres B, Miguel; Montanez, Juan.

    1986-04-01

    This publication gives a practical orientation on industrial radiography. The first chapters deal with basic facts that are useful for professional work in this field. It comprises topics such as generation of X-rays, equipment being used, radiographic films, sensibility, and the penetrameters used. This publication also describes the most used radiographic techniques and the processing of the radiographic film. It contains practical recommendations on how to obtain a good radiographic inspection. It states the reasons for defects in the radiographies. Two annexes are attached which include tables for the selection of penetrameters according to the ASME and DIN codes as well as the time needed for development and fixing according to the temperature

  7. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  8. Neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi

    1988-01-01

    The thermal neutron absorption coefficient is essentially different from the X-ray absorption coefficient. Each substance has a characteristic absorption coefficient regardless of its density. Neutron deams have the following features: (1) neutrons are not transmitted efficiently by low molecular weight substances, (2) they are transmitted efficiently by heavy metals, and (3) the transmittance differs among isotopes. Thus, neutron beams are suitable for cheking for foreign matters in heavy metals and testing of composites consisting of both heavy and light materials. A neutron source generates fast neutrons, which should be converted into thermal neutrons by reducing their energy. Major neutron souces include nuclear reactors, radioisotopes and particle accelerators. Photographic films and television systems are mainly used to observe neutron transmission images. Computers are employed for image processing, computerized tomography and three-dimensional analysis. The major applications of neutron radiography include inspection of neclear fuel; evaluation of material for airplane; observation of fuel in the engine and oil in the hydraulic systems in airplanes; testing of composite materials; etc. (Nogami, K.)

  9. Diagnostic value of full-mouth radiography in dogs

    International Nuclear Information System (INIS)

    Verstraete, F.J.M.; Kass, P.H.; Terpak, C.H.

    1998-01-01

    Objective-To determine the diagnostic value of full-mouth radiography in dogs.Sample Population-Prospective series of 226 dogs referred for dental treatment without previous full-mouth radiographic views being available. Procedure-In a prospective nested case-control analysis of multiple outcomes in a hospital cohort of dogs presented for dental treatment, full-mouth radiographic views were obtained prior to oral examination and charting. After treatment, clinical and radiographic findings were compared, with reference to presenting problems, main clinical findings, additional information obtained from the radiographs, and unexpected radiographic findings. The importance of the radiographic findings in therapeutic decision-making was assessed. Results-The main clinical findings were radiographically confirmed in all dogs. Selected presenting problems and main clinical findings yielded significantly increased odds ratios for a variety of other conditions, either expected or unexpected. Radiographs of teeth without clinical lesions yielded incidental or clinically important findings in 41.7 and 27.8% of dogs, respectively, and were considered of no clinical value in 30.5%. Radiographs of teeth with clinical lesions merely confirmed the findings in 24.3% of dogs, yielded additional or clinically essential information in 50.0 and 22.6%, respectively, and were considered of no value in 3.1%. Older dogs derived more benefit from full-mouth radiography than did younger dogs. Incidental findings were more common in larger dogs. Clinical Relevance-Diagnostic yield of full-mouth radiography in new canine patients referred for dental treatment is high, and the routine use of such radiographs is justifiable

  10. Effective dose for patient in multimode panoramic radiography

    International Nuclear Information System (INIS)

    Yasaki, Shiro; Daibo, Motoji

    1999-01-01

    In recent years, multimode panoramic radiography has had various functions, such as the auto exposure function, auto focus function (auto function), TMJ radiography and tomogram radiography functions. The purpose of this study was to estimate the effective dose for patients in each mode of the new multimode panoramic radiography (J. MORITA MFG. CORP. Dental Panorama X-ray Apparatus: Veraview Scope X 600). The absorbed doses in important organs involved in the causation of stochastic effects were measured by a thermoluminescent dosimeter using RANDO phantom. The effective doses were calculated using modified tissue weighting factors recommended by the International Commission on Radiological Protection (ICRP) in 1999. The mean field size over skin in typical panoramic and tomographic examinations was about 3% and 0.4% of the total body surface area of 15000 cm 2 . Assuming that the incidence of skin cancer is proportional to the area of skin exposed to ionizing radiation, the tissue weighting factor of skin can be estimated to be about 0.0003 and 0.00004. The estimate in effective dose was lower (5.3 μSv) in the panoramic auto function mode (an average exposure condition of 69 kV 7 mA) than that (6.5-13.8 μSv) in the linear tomogram modes. Since the linear tomogram mode requires a scout view, such as standard panoramic radiography, the dose in the linear tomogram mode becomes higher than other modes. A percentage of gonad doses in effective doses was negligible. (author)

  11. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available   Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  12. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  13. Game theoretic analysis of physical protection system design

    International Nuclear Information System (INIS)

    Canion, B.; Schneider, E.; Bickel, E.; Hadlock, C.; Morton, D.

    2013-01-01

    The physical protection system (PPS) of a fictional small modular reactor (SMR) facility have been modeled as a platform for a game theoretic approach to security decision analysis. To demonstrate the game theoretic approach, a rational adversary with complete knowledge of the facility has been modeled attempting a sabotage attack. The adversary adjusts his decisions in response to investments made by the defender to enhance the security measures. This can lead to a conservative physical protection system design. Since defender upgrades were limited by a budget, cost benefit analysis may be conducted upon security upgrades. One approach to cost benefit analysis is the efficient frontier, which depicts the reduction in expected consequence per incremental increase in the security budget

  14. The technological development of neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Berger, H.

    1977-01-01

    Neutron radiography is a relatively recent technological development in the annals of non-destructive evaluation. It promises to play a role of increasing importance as the technology is further developed. The technique is placed in prospective with regard to other non-destructive evaluation methods in this paper. The history of the development of neutron radiography is traced to the early work of Becker, Bothe and the Joliot-Curies in Europe, and to the work of Chadwick in Great Britain. Details of the experiments which led to the discovery of the neutron by Chadwick in 1932, nuclear properties and energy classifications of neutrons, and the various interactions of neutrons with matter are discussed in detail. A history of neutron radiography is presented which outlines the early experiments by Kallmann and Kuhn; these experiments led to the production of the first neutron radiograph in Germany in 1938. The paper continues with a description of the general techniques that are characteristic of the neutron radiographic process. The breadth and extent of present neutron radiographic technology is discussed as a conclusion of the paper. (author)

  15. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  17. Radiography of osseous lesions of the bovine locomotor system

    International Nuclear Information System (INIS)

    Blond, L.; Beauregard, G.; Mulon, P.Y.

    2006-01-01

    Radiography is the ancillary test of choice for lameness in cattle. Osseous lesions due to osteoporosis, osteitis or osteomyelitis and sequestrae can be visualised. Radiography is the only ancillary examination that provides a thorough investigation of the lesion affecting a bovine presented with a non-weight bearing suspected fracture and limb inflammation associated with soft tissue crepitation. Radiography is the only method to ensure that the fracture is not open. It facilitates follow-up of healing of osseous lesions. The period of time required for immobilisation can be adjusted depending on the type of lesions [it

  18. Studies on image quality and dose exposure in chest radiography in children

    International Nuclear Information System (INIS)

    Schumacher, R.

    1985-01-01

    Chest radiography accounts for almost 50% of all radiographies in radiological departments for children, thus clearly dominating X-ray performances. The indications for examination in children are frequent infections of the upper airways, congenital cardiac defects, and controls in oncological patients. By contrast, indications for radioscopy of the chest organs which figure greatly in adult age and are often required concurrently with every chest radiography, are rather rare in the patient group of a paediatric X-ray department with their rate of c. 0.5% related to chest radiography. Chest radiographs and phantom radiographs were produced using different techniques and were compared by means of subjective and objective image quality parameters. Concurrently, thermoluminescence dosimetry was used to perform dose measurements of the small gonadal dose occurring in patients in chest radiographies. The study aimed at finding a chest radiography technique appropriate for use in paediatric radiology while considering both image quality parameters and the radiation dose required for producing pictures. (orig./DG) [de

  19. Quantitative neutron radiography using neutron absorbing honeycomb

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Oda, Masahiro; Takahashi, Kenji; Ohkubo, Kohei; Tasaka, Kanji; Tsuruno, Akira; Matsubayashi, Masahito.

    1993-01-01

    This investigation concerns quantitative neutron radiography and computed tomography by using a neutron absorbing honeycomb collimator. By setting the neutron absorbing honeycomb collimator between object and imaging system, neutrons scattered in the object were absorbed by the honeycomb material and eliminated before coming to the imaging system, but the neutrons which were transmitted the object without interaction could reach the imaging system. The image by purely transmitted neutrons gives the quantitative information. Two honeycombs were prepared with coating of boron nitride and gadolinium oxide and evaluated for the quantitative application. The relation between the neutron total cross section and the attenuation coefficient confirmed that they were in a fairly good agreement. Application to quantitative computed tomography was also successfully conducted. The new neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improved remarkably the quantitativeness of the neutron radiography and computed tomography. (author)

  20. Real-time transfer and display of radiography image

    International Nuclear Information System (INIS)

    Liu Ximing; Wu Zhifang; Miao Jicheng

    2000-01-01

    The information process network of cobalt-60 container inspection system is a local area network based on PC. The system requires reliable transfer of radiography image between collection station and process station and the real-time display of radiography image on process station. Due to the very high data acquisition rate, in order to realize the real-time transfer and display of radiography image, 100 M Ethernet technology and network process communication technology are adopted in the system. Windows Sockets is the most common process communication technology up to now. Several kinds of process communication way under Windows Sockets technology are compared and tested. Finally the author realized 1 Mbyte/s' inerrant image transfer and real-time display with blocked datagram transfer technology

  1. Digital vs conventional radiography: cost and revenue analysis

    International Nuclear Information System (INIS)

    Dalla Palma, L.; Cuttin, R.; Rimondini, A.; Grisi, G.

    1999-01-01

    The objective of this study was to analyse and compare the operating and investment costs of two radiographic systems, a conventional and a digital one, and to evaluate the cost/revenue ratio of the two systems. The radiological activity over 1 year for chest and skeletal exams was evaluated: 13,401 chest and 7,124 skeletal exams were considered. The following parameters of variable costs were evaluated: the difference between variable proportional costs of the two technologies, the effective variable cost of any size film, including the chemicals, and for different sizes of digital film, variable costs of chest plus skeletal exams performed with the two techniques. Afterwards the economical effect was considered taking into account depreciation during a time of utilization ranging between 8 and 4 years. In the second part of the analysis the total cost and the revenues of the two technologies were determined. The comparison between the digital and conventional systems has shown the following aspects: 1. Digital radiography system has a much higher investment cost in comparison with the conventional one. 2. Operating costs of digital equipment are higher or lower depending on the film size used. Evaluating chest X-ray we reach a breakeven point after 1 year and 10,000 exams only if displayed over 8 x 10-in. film and after 30,000 if displayed over a 11 x 14-in. film. 3. The total cost (variable cost, technology cost, labour cost) of digital technology is lower than that of the conventional system by 20 % on average using 8 x 10-in. film size. 4. Digital technology also allows lesser film waste and lesser film per exam (orig.)

  2. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND... Records of the specific license for industrial radiography. Each licensee shall maintain a copy of its...

  3. New developments in radiography. An overview

    International Nuclear Information System (INIS)

    Berger, H.; Orphan, V.

    1983-01-01

    Techniques for radiographic inspection are undergoing change. Changes in X-ray sources include higher voltage and current, pulse techniques, smaller focal spots, portability, ease-of-use, and high reliability. Detector improvements include better films, screens and scintillators, real-time methods, electrostatic methods and solid state detectors. We now use many radiation for radiography (X-rays, gamma rays, neutrons and charged particles) and can process radiographic information to accomplish such things as image enhancement, tomography and digital radiography. In this review, the authors discuss some of these developments, many of which have not been applied - or widely applied in the nuclear industry

  4. Radiologic accidents in industrial gamma radiography - Brazilian cases

    International Nuclear Information System (INIS)

    Silva, Francisco Cesar Augusto da

    1997-01-01

    Three severe radiological accidents in industrial gamma radiography happened in Brazil during the period of 1985 to 1988. Five operators and nineteen public people were involved. These accidents caused some injuries in parts of the body, mainly hands and fingers. The main causes were faults in source monitoring, inadequate routine procedures and unknowing of radiation warning symbol by public people. The present paper shows the Brazilian cases of radiological accidents and makes some analysis of them. (author)

  5. Non-destructive testing of rocket fuse by thermal neutron radiography

    International Nuclear Information System (INIS)

    An Fulin; Li Furong

    1999-01-01

    A neutron radiography system in reactor horizontal hole of Tsinghua University was introduced, and its capability of neutron radiography was evaluated by theory and experiment, the non-destructive testing for rocket fuse is successful

  6. A guide to collect data from abnormal events in industrial radiography

    International Nuclear Information System (INIS)

    Martins, M.M.; Silva, F.C.; Tahuata, L.

    1996-01-01

    The review of abnormal radiological events provides important information to evaluate the reasons of their cause. The IAEA and other institutions have dedicated special attention to this subject, studying mainly radiological accidents that affected individuals from the public and workers exposed. According to UNSCEAR, industrial radiography and other radiographic techniques are responsible for the great number of overexposure events. This paper can be used by health physicists and other professionals as a guide to extract the most important information related to abnormal events that happen in industrial radiography. This guide was used in 1992 in the information registration data base (1976-1992) of the Brazilian Nuclear Energy Commission (CNEN), where 175 events were identified with a minimal number of information for the analysis. The collected data is presented too. (authors). 6 refs., 1 ill

  7. Neutron radiography of aircraft composite flight control surfaces

    International Nuclear Information System (INIS)

    Lewis, W.J.; Bennett, L.G.I.; Chalovich, T.R.; Francescone, O.

    2001-01-01

    A small (20 kWth), safe, pool-type nuclear research reactor called the SLOWPOKE-2 is located at the Royal Military College of Canada (RMC). The reactor was originally installed for teaching, training, research and semi-routine analysis, specifically, neutron activation analysis. It was envisioned that the neutrons from the SLOWPOKE-2 could also be used for neutron radiography, and so a research program was initiated to develop this technology. Over a period of approximately 15 years, and through a series of successive modifications, a neutron radiography system (NRS) was developed. Once completed, several applications of the technology have been demonstrated, including the nondestructive examination of the composite flight control surfaces from the Canadian Air Force's primary jet fighter, the CF18 Hornet aircraft. An initial trial was setup to investigate the flight control surfaces of 3 aircraft, to determine the parameters for a final licensed system, and to compare the results to other nondestructive methods. Over 500 neutron radiographs were made for these first 3 aircraft, and moisture and corrosion were discovered in the honeycomb structure and hydration was found in the composite and adhesive layers. In comparison with other NDT methods, neutron radiography was the only method that could detect the small areas of corrosion and moisture entrapment. However, before examining an additional 7 aircraft, the recommended modifications to the NRS were undertaken. These modifications were necessary to accommodate the larger flight control surfaces safely by incorporating flexible conformable shielding. As well, to expedite inspections so that all flight control surfaces from one aircraft could be completed in less than two weeks, there was a need to decrease the exposure time by both faster film/conversion screen combinations and by incorporating the capability of near realtime, digital radioscopy. Finally, as there are no inspection specific image quality

  8. Theoretical concepts of X-ray nanoscale analysis theory and applications

    CERN Document Server

    Benediktovitch, Andrei; Ulyanenkov, Alexander

    2013-01-01

    This book provides a concise survey of modern theoretical concepts of X-ray materials analysis. The principle features of the book are: basics of X-ray scattering, interaction between X-rays and matter and new theoretical concepts of X-ray scattering. The various X-ray techniques are considered in detail: high-resolution X-ray diffraction, X-ray reflectivity, grazing-incidence small-angle X-ray scattering and X-ray residual stress analysis. All the theoretical methods presented use the unified physical approach. This makes the book especially useful for readers learning and performing data ana

  9. Tube Bulge Process : Theoretical Analysis and Finite Element Simulations

    International Nuclear Information System (INIS)

    Velasco, Raphael; Boudeau, Nathalie

    2007-01-01

    This paper is focused on the determination of mechanics characteristics for tubular materials, using tube bulge process. A comparative study is made between two different models: theoretical model and finite element analysis. The theoretical model is completely developed, based first on a geometrical analysis of the tube profile during bulging, which is assumed to strain in arc of circles. Strain and stress analysis complete the theoretical model, which allows to evaluate tube thickness and state of stress, at any point of the free bulge region. Free bulging of a 304L stainless steel is simulated using Ls-Dyna 970. To validate FE simulations approach, a comparison between theoretical and finite elements models is led on several parameters such as: thickness variation at the free bulge region pole with bulge height, tube thickness variation with z axial coordinate, and von Mises stress variation with plastic strain. Finally, the influence of geometrical parameters deviations on flow stress curve is observed using analytical model: deviations of the tube outer diameter, its initial thickness and the bulge height measurement are taken into account to obtain a resulting error on plastic strain and von Mises stress

  10. Medium range energy proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.

    1982-02-01

    This thesis is concerned with a new application of the strong nuclear interaction aiming to radiographic analysis. In this work, some physical processes have been analyzed with detail; these processes play a fundamental role in method quality and limitations; they have been detailed to facilitate comprehension to scientists who are not nuclear physicists. To better appreciate specific qualities of the RDN (Radiography par Diffusion Nucleaire), a chapter reviews strong nuclear interaction properties. Then, the experimental device is described, processing and acquisition system. Spatial resolution and sensitivity limits are studied. Results are presented [fr

  11. Irradiation hazards and safety standards for patients in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, B D.P.

    1975-07-01

    The historical developments which have led to a reduction in the hazards or potential hazards to patients in dental radiography are reviewed. Based on a simple risk estimate, the safety of present-day techniques employed in routine dental radiography is assessed. Also included in the review is a description of techniques used and results obtained from the National Radiation Laboratory's (NRL) surveillance programme of patients' exposure to irradiation in dental radiography. The possibilities of and need for achieving further reductions of irradiation are discussed.

  12. Value of postmortem thoracic CT over radiography in imaging of pediatric rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Terence S.; Babyn, Paul S. [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Reyes, Jeanette A.; Chiasson, David A. [The Hospital for Sick Children, Department of Paediatric Laboratory Medicine, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Berdon, Walter E. [Columbia Presbyterian Medical Center, Babies Hospital, Department of Radiology, New York, NY (United States)

    2011-06-15

    Studies have reported that thoracic CT may provide greater sensitivity compared with radiography in detection of pediatric rib fractures and fracture healing. The additional sensitivity afforded by thoracic CT may have medicolegal implications where abuse is suspected. To determine the additional value of postmortem thoracic CT compared with radiography in detecting pediatric rib fractures, and fracture healing, using autopsy findings as a gold standard. We retrospectively reviewed 56 coroner's cases with postmortem radiography and CT thoracic survey. All studies underwent primary interpretation by one or two radiologists. The study radiologist independently reviewed all images from 13 patients with positive findings on radiography, CT or autopsy. Sensitivity and specificity between observers and imaging modalities were compared. Primary interpretation: Fractures were recognized on radiography in 5/12 patients who had fractures found at autopsy, and on CT in 8/12 patients. In total, 29% (24/83) of fractures were reported on radiography, and 51% (52/101) of fractures were reported on CT. Study radiologist: Fractures were recognized on radiography in 7/12 patients who had fractures found at autopsy, and on CT in 11/12 patients. In total, 46% (38/83) of fractures were reported on radiography, and 85% (86/101) of fractures were reported on CT. Postmortem thoracic CT provides greater sensitivity than radiography in detecting pediatric rib fractures, most notably in anterior and posterior fractures. However, the degree of improvement in sensitivity provided by CT might depend on observer experience. (orig.)

  13. Wireless Information-Theoretic Security in an Outdoor Topology with Obstacles: Theoretical Analysis and Experimental Measurements

    Directory of Open Access Journals (Sweden)

    Dagiuklas Tasos

    2011-01-01

    Full Text Available This paper presents a Wireless Information-Theoretic Security (WITS scheme, which has been recently introduced as a robust physical layer-based security solution, especially for infrastructureless networks. An autonomic network of moving users was implemented via 802.11n nodes of an ad hoc network for an outdoor topology with obstacles. Obstructed-Line-of-Sight (OLOS and Non-Line-of-Sight (NLOS propagation scenarios were examined. Low-speed user movement was considered, so that Doppler spread could be discarded. A transmitter and a legitimate receiver exchanged information in the presence of a moving eavesdropper. Average Signal-to-Noise Ratio (SNR values were acquired for both the main and the wiretap channel, and the Probability of Nonzero Secrecy Capacity was calculated based on theoretical formula. Experimental results validate theoretical findings stressing the importance of user location and mobility schemes on the robustness of Wireless Information-Theoretic Security and call for further theoretical analysis.

  14. Recognition of internal structure of unknown objects with simultaneous neutron and gamma radiography

    International Nuclear Information System (INIS)

    Moghadam, K.K.; Nasseri, M.M.

    2004-01-01

    Generally speaking in customary industrial and medical radiography, there is no tendency to reveal the nature of the samples. Ordinarily, the main objective of taking a radiograph is to show the position and dimension of unknown parts, inside the test object and to determine cracks, defects, etc. Whereas in radiography many important factors such as material cross-sections and build-up factors are also involved. In this paper, by using both neutron and gamma radiography techniques, some mathematical relations were successfully generated, in order to calculate the neutron and gamma total macroscopic cross-sections of some unknown elements in the presence of the other elements. For this work, some test pieces were defined and made of lead, silver, copper, Nickel, tin, graphite and polyethylene. The neutron radiography facility at Tehran Research Reactor (TRR) was used as mixed neutron and gamma radiography source (Proceedings of the Second World Conference on Neutron Radiography, Paris, France, pp. 25-32). On testing of a correction of the above-mentioned generated relations, a new technique of simultaneous neutron and gamma radiography was also investigated

  15. Gamma-radiography techniques applied to quality control of welds in water pipe lines

    International Nuclear Information System (INIS)

    Sanchez, W.; Oki, H.

    1974-01-01

    Non-destructive testing of welds may be done by the gamma-radiography technique, in order to detect the presence or absence of discontinuities and defects in the bulk of deposited metal and near the base metal. Gamma-radiography allows the documentation of the test with a complete inspection record, which is a fact not common in other non-destructive testing methods. In the quality control of longitudinal or transversal welds in water pipe lines, two exposition techniques are used: double wall and panoramic exposition. Three different water pipe lines systems have analysed for weld defects, giving a total of 16,000 gamma-radiographies. The tests were made according to the criteria established by the ASME standard. The principal metallic discontinuites found in the weld were: porosity (32%), lack of penetration (29%), lack of fusion (20%), and slag inclusion (19%). The percentage of gamma-radiographies showing welds without defects was 39% (6168 gamma-radiographies). On the other hand, 53% (8502 gamma-radiographies) showed the presence of acceptable discontinuities and 8% (1330 gamma-radiographies) were rejected according to the ASME standards [pt

  16. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  17. Compton radiography, 2. Clinical significance of Compton radiography of a chest phantom

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, S; Sera, K; Fukuda, H; Shishido, F [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis, Leprosy and Cancer; Mishina, H

    1977-09-01

    Compton radiography, a tomographic technic with Compton-scattered rays of a monochromatic gamma ray beam, was feasible of tomographing a chest phantom. The result suggested that the technic could be extended to imaging of the lung and the surrounding structures of the chest wall, mediastinum and liver in Compton tomographic mode.

  18. Retrograde contrast radiography of the distal portions of the intestinal tract in foals

    International Nuclear Information System (INIS)

    Fischer, A.T.; Yarbrough, T.Y.

    1995-01-01

    A technique for retrograde contrast radiography of the distal portions of the intestinal tract of foals was developed and then performed in 25 foals (1 to 30 days old) with colic. Retrograde contrast radiography was shown to be sensitive (100%) and specific (100%) for evaluating obstruction of the small colon or transverse colon. It was slightly less sensitive (86%) and specific (83%) for evaluation of the entire large colon, particularly in older foals. Retrograde contrast radiography provided increased diagnostic capability, compared with that for noncontrast radiography. Retrograde contrast radiography can provide valuable information when evaluating foals with colic and should be part of the diagnostic evaluation

  19. Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index

    International Nuclear Information System (INIS)

    Peters, Sinead E.; Brennan, Patrick C.

    2002-01-01

    Manufacturers offer exposure indices as a safeguard against overexposure in computed radiography, but the basis for recommended values is unclear. This study establishes an optimum exposure index to be used as a guideline for a specific CR system to minimise radiation exposures for computed mobile chest radiography, and compares this with manufacturer guidelines and current practice. An anthropomorphic phantom was employed to establish the minimum milliamperes consistent with acceptable image quality for mobile chest radiography images. This was found to be 2 mAs. Consecutively, 10 patients were exposed with this optimised milliampere value and 10 patients were exposed with the 3.2 mAs routinely used in the department of the study. Image quality was objectively assessed using anatomical criteria. Retrospective analyses of 717 exposure indices recorded over 2 months from mobile chest examinations were performed. The optimised milliampere value provided a significant reduction of the average exposure index from 1840 to 1570 (p<0.0001). This new ''optimum'' exposure index is substantially lower than manufacturer guidelines of 2000 and significantly lower than exposure indices from the retrospective study (1890). Retrospective data showed a significant increase in exposure indices if the examination was performed out of hours. The data provided by this study emphasise the need for clinicians and personnel to consider establishing their own optimum exposure indices for digital investigations rather than simply accepting manufacturers' guidelines. Such an approach, along with regular monitoring of indices, may result in a substantial reduction in patient exposure. (orig.)

  20. Theoretical analysis of balanced truncation for linear switched systems

    DEFF Research Database (Denmark)

    Petreczky, Mihaly; Wisniewski, Rafal; Leth, John-Josef

    2012-01-01

    In this paper we present theoretical analysis of model reduction of linear switched systems based on balanced truncation, presented in [1,2]. More precisely, (1) we provide a bound on the estimation error using L2 gain, (2) we provide a system theoretic interpretation of grammians and their singu......In this paper we present theoretical analysis of model reduction of linear switched systems based on balanced truncation, presented in [1,2]. More precisely, (1) we provide a bound on the estimation error using L2 gain, (2) we provide a system theoretic interpretation of grammians...... for showing this independence is realization theory of linear switched systems. [1] H. R. Shaker and R. Wisniewski, "Generalized gramian framework for model/controller order reduction of switched systems", International Journal of Systems Science, Vol. 42, Issue 8, 2011, 1277-1291. [2] H. R. Shaker and R....... Wisniewski, "Switched Systems Reduction Framework Based on Convex Combination of Generalized Gramians", Journal of Control Science and Engineering, 2009....

  1. Registration of pencil beam proton radiography data with X-ray CT.

    Science.gov (United States)

    Deffet, Sylvain; Macq, Benoît; Righetto, Roberto; Vander Stappen, François; Farace, Paolo

    2017-10-01

    Proton radiography seems to be a promising tool for assessing the quality of the stopping power computation in proton therapy. However, range error maps obtained on the basis of proton radiographs are very sensitive to small misalignment between the planning CT and the proton radiography acquisitions. In order to be able to mitigate misalignment in postprocessing, the authors implemented a fast method for registration between pencil proton radiography data obtained with a multilayer ionization chamber (MLIC) and an X-ray CT acquired on a head phantom. The registration was performed by optimizing a cost function which performs a comparison between the acquired data and simulated integral depth-dose curves. Two methodologies were considered, one based on dual orthogonal projections and the other one on a single projection. For each methodology, the robustness of the registration algorithm with respect to three confounding factors (measurement noise, CT calibration errors, and spot spacing) was investigated by testing the accuracy of the method through simulations based on a CT scan of a head phantom. The present registration method showed robust convergence towards the optimal solution. For the level of measurement noise and the uncertainty in the stopping power computation expected in proton radiography using a MLIC, the accuracy appeared to be better than 0.3° for angles and 0.3 mm for translations by use of the appropriate cost function. The spot spacing analysis showed that a spacing larger than the 5 mm used by other authors for the investigation of a MLIC for proton radiography led to results with absolute accuracy better than 0.3° for angles and 1 mm for translations when orthogonal proton radiographs were fed into the algorithm. In the case of a single projection, 6 mm was the largest spot spacing presenting an acceptable registration accuracy. For registration of proton radiography data with X-ray CT, the use of a direct ray-tracing algorithm to compute

  2. Findings and recommendations of the competency based standards project for radiography

    International Nuclear Information System (INIS)

    Egan, Ingrid

    1993-01-01

    In February 1992, the National Office of Overseas Skills Recognition funded a $150,000 research project for the development of Competency Based Standards for the professions of Medical Radiation Science (MRS). The four professions of MRS are now considered to be: Radiography, Radiation Therapy, Nuclear Medicine Science and Sonography. The four national documents have aimed at describing the performances of the MRS practitioner at entry level to the profession. Findings from survey and interviews indicate that the existing structure of the undergraduate courses should be reviewed with emphasis on: problem solving skills, theater radiography, paediatric radiography, image interpretation or radiography pathology as well as venepuncture, if accepted nationally. . 5 refs., 1 tab., 5 figs

  3. Mature students' perspectives of studying radiography

    International Nuclear Information System (INIS)

    Williams, M.; Decker, S.

    2009-01-01

    The study set out to explore the experiences of all final year mature students on a diagnostic radiography course, in one United Kingdom University. The aims were to identify any difficulties they may have had and to make recommendations to improve mature students' learning experiences with the hope of lowering attrition rates in this group. A qualitative study involving one-to-one audio recorded interviews was utilised. Analysis of the transcripts of interviews suggested that the group believed that their maturity and previous experiences helped them in the clinical environment and put them in a good position, when asked, to counsel younger students. However for some of the mature students these experiential skills did not extend fully into seeking appropriate support for themselves. The mature students were found to be highly motivated but there was a conflict between balancing clinical and academic aspects of studying as well as balancing studying with home life. The group was found to be unprepared for the volume of academic work and its detrimental effect on family life as they sacrificed other aspects of their lives in order to complete the course. It is recommended that forewarning and forearming prospective mature students be considered by radiography education providers. Setting up and utilising an on-line forum providing a 24/7 peer support environment would aid in coping with academic, clinical or personal problems

  4. Void fraction measurements using neutron radiography

    International Nuclear Information System (INIS)

    Glickstein, S.S.; Vance, W.H.; Joo, H.

    1992-01-01

    Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10 6 n/cm 2 /s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image analysis techniques were employed to extract void fractions from the data which was recorded on videotape. This consisted of time averaging 256 video frames and measuring the gray level distribution throughout the region. The distribution of the measured void fraction across the duct was determined for various air/water mixtures. Details of the results of experiments for a variety of air and water flow conditions are presented

  5. Large-image intensifier photofluorography and conventional radiography in pulmonary emphysema

    International Nuclear Information System (INIS)

    Manninen, H.; Partanen, K.; Soimakallio, S.; Rytkoenen, H.

    1988-01-01

    Large-screen image intensifier (II) photofluorography was compared with full-size screen-film chest radiography in the diagnosis of pulmonary emphysema in 84 patients. Photospot films and conventional radiographs were interpreted independently by three radiologists. Computed tomography (CT) was used as an independent reference technique, and diagnostic performance of chest radiography in various CT patterns of emphysema was evaluated. The difference in diagnostic sensitivity for emphysema in favor of conventional chest radiography over photofluorography (0.65 versus 0.56) was statistically significant (p < 0.05). Specificity of the imaging modalities was equal: 0.78 in full-size films and 0.77 in photospot films. All CT patterns of emphysema had great false negative response rates in chest radiography, which is an inaccurate technique for the diagnosis of emphysema. CT is required for reliable radiologic evaluation of emphysema. (orig.)

  6. A method of detector correction for cosmic ray muon radiography

    International Nuclear Information System (INIS)

    Liu Yuanyuan; Zhao Ziran; Chen Zhiqiang; Zhang Li; Wang Zhentian

    2008-01-01

    Cosmic ray muon radiography which has good penetrability and sensitivity to high-Z materials is an effective way for detecting shielded nuclear materials. The problem of data correction is one of the key points of muon radiography technique. Because of the influence of environmental background, environmental yawp and error of detectors, the raw data can not be used directly. If we used the raw data as the usable data to reconstruct without any corrections, it would turn up terrible artifacts. Based on the characteristics of the muon radiography system, aimed at the error of detectors, this paper proposes a method of detector correction. The simulation experiments demonstrate that this method can effectively correct the error produced by detectors. Therefore, we can say that it does a further step to let the technique of cosmic muon radiography into out real life. (authors)

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that those parts of a patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of Bone X-ray (Radiography)? ...

  8. Clinical aspects of plain film radiography of the chest

    International Nuclear Information System (INIS)

    Ravin, C.E.

    1988-01-01

    In spite of the introduction of a number of intriguing new imaging modalities including Computed Tomography and Magnetic Resonance Imaging, the plain film of the chest remains the mainstay of thoracic imaging. It is estimated that more than fifty million chest radiographs are performed each year in the United States. In the attempt to compare newer imaging modalities with the standard plain film of the chest, investigators have been forced to adopt specific structures and or disease processes to be analyzed. To some extent identification of normally appearing structures in the mediastinum and lung parenchyma serves as a clue as to the ability of a newer technology to compete with or be compared with the plain film. However, as most authors would acknowledge, the ability to portray normal underlying anatomy is only the first step in analysis in intrathoracic disease. Experimental design becomes somewhat more complicated when one wishes to move beyond normal anatomy to analysis of disease processes. The challenge of digital radiography in whatever form it may take will be to equal or exceed the standard established by conventional plain film radiography and deliver such service at reasonable cost in a manner which allows for appropriate patient throughput

  9. Cold neutron radiography using low power accelerator

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki; Iwasa, Hirokatu

    1993-01-01

    A cold neutron source which can be adopted at a low power accelerator was studied. Time-of-flight radiography using the cold neutron source was performed. It is suggested that time-of-flight cold neutron radiography has possibility to distinguish the materials more clearly than the traditional film method since large contrast differences can be obtained by using digital data of the neutron intensity at different energies from thermal to cold region. Material will be identified at the same time by this method. (author)

  10. Gonadal dose reduction in lumbar spine radiography

    International Nuclear Information System (INIS)

    Moilanen, A.; Kokko, M.L.; Pitkaenen, M.

    1983-01-01

    Different ways to minimize the gonadal dose in lumbar spine radiography have been studied. Two hundred and fifty lumbar spine radiographs were reviewed to assess the clinical need for lateral L5/S1 projection. Modern film/screen combinations and gonadal shielding of externally scattered radiation play a major role in the reduction of the genetic dose. The number of exposures should be minimized. Our results show that two projections, anteroposterior (AP) and lateral, appear to be sufficient in routine radiography of the lumbar spine. (orig.)

  11. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  12. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2011-03-15

    The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. This report was carried out by review of the literatures. Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

  13. Diagnostic approach to reflex sympathetic dystrophy after fracture: radiography or bone scintigraphy?

    International Nuclear Information System (INIS)

    Todorovic-Tirnanic, M.; Obradovic, V.; Han, R.; Goldner, B.; Stankovic, D.; Sekulic, D.; Lazic, T.; Djordjevic, B.

    1995-01-01

    The aim of this paper was to compare the value of bone scintigraphy and radiography in the early diagnosis of post-fracture reflex sympathetic dystrophy (RSD). Thirty-seven adult patients with post-fracture RSD (28 in the first and nine in the second clinical stage of RSD), as well as seven patients with fracture but without RSD (control group), were investigated by radiography and bone scintigraphy. All of them were immobilized (duration of immobilization: 4-22 weeks). In 21 persons three phase bone scintigraphy was performed. The best distinction between the control group and the RSD patients was achieved by delayed bone scintigrams. The sensitivity (97%), positive predictive value (97%) and accuracy (95%) of delayed bone scintigraphy were very high compared to the values for radiography, which were 73%, 90% and 70% respectively. Bone scintigraphy also displayed higher specificity (86%) and negative predictive value (86%) than radiography (57% and 29% respectively). In the first clinical stage the difference between the accuracy of bone scintigraphy (97%) and radiography (63%) was greater than for the whole group. In the second stage of RSD the accuracy of bone scintigraphy (86%) and radiography (81%) was similar. Three-phase bone scintigraphy is not necessary for the diagnosis of post-fracture RSD: it is sufficient to perform delayed bone scintigraphy. It is concluded that bone scintigraphy is to be preferred to radiography for the early diagnosis of post-fracture RSD in the first clinical stage. In the second stage the diagnostic capabilities of bone scintigraphy and radiography are more comparable. (orig.)

  14. Corrections on energy spectrum and scattering for fast neutron radiography at NECTAR facility

    International Nuclear Information System (INIS)

    Liu Shuquan; Thomas, Boucherl; Li Hang; Zou Yubin; Lu Yuanrong; Guo Zhiyu

    2013-01-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM-Ⅱ in Technische Universitaet Mounchen (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections. (authors)

  15. Corrections on energy spectrum and scatterings for fast neutron radiography at NECTAR facility

    Science.gov (United States)

    Liu, Shu-Quan; Bücherl, Thomas; Li, Hang; Zou, Yu-Bin; Lu, Yuan-Rong; Guo, Zhi-Yu

    2013-11-01

    Distortions caused by the neutron spectrum and scattered neutrons are major problems in fast neutron radiography and should be considered for improving the image quality. This paper puts emphasis on the removal of these image distortions and deviations for fast neutron radiography performed at the NECTAR facility of the research reactor FRM- II in Technische Universität München (TUM), Germany. The NECTAR energy spectrum is analyzed and established to modify the influence caused by the neutron spectrum, and the Point Scattered Function (PScF) simulated by the Monte-Carlo program MCNPX is used to evaluate scattering effects from the object and improve image quality. Good analysis results prove the sound effects of the above two corrections.

  16. Inform: Efficient Information-Theoretic Analysis of Collective Behaviors

    Directory of Open Access Journals (Sweden)

    Douglas G. Moore

    2018-06-01

    Full Text Available The study of collective behavior has traditionally relied on a variety of different methodological tools ranging from more theoretical methods such as population or game-theoretic models to empirical ones like Monte Carlo or multi-agent simulations. An approach that is increasingly being explored is the use of information theory as a methodological framework to study the flow of information and the statistical properties of collectives of interacting agents. While a few general purpose toolkits exist, most of the existing software for information theoretic analysis of collective systems is limited in scope. We introduce Inform, an open-source framework for efficient information theoretic analysis that exploits the computational power of a C library while simplifying its use through a variety of wrappers for common higher-level scripting languages. We focus on two such wrappers here: PyInform (Python and rinform (R. Inform and its wrappers are cross-platform and general-purpose. They include classical information-theoretic measures, measures of information dynamics and information-based methods to study the statistical behavior of collective systems, and expose a lower-level API that allow users to construct measures of their own. We describe the architecture of the Inform framework, study its computational efficiency and use it to analyze three different case studies of collective behavior: biochemical information storage in regenerating planaria, nest-site selection in the ant Temnothorax rugatulus, and collective decision making in multi-agent simulations.

  17. Problems associated with digital luminescence radiography in the neonate and young infant

    International Nuclear Information System (INIS)

    Arthur, R.J.; Pease, J.N.

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted. (orig.)

  18. Computed radiography imaging plates and associated methods of manufacture

    Science.gov (United States)

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  19. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  20. Recommended practice for the neutron radiography of nuclear fuels

    International Nuclear Information System (INIS)

    Matfield, R.S.

    1983-01-01

    The document is part of a Neutron Radiography Handbook being prepared by a Neutron Radiography Working Party of the European Community. It commences with a description of the information that should be provided by a user of neutron radiography services and then gives recommendations on the equipment to be used. This is followed by two sections on the techniques to be used for detecting discontinuities and the making of measurements on nuclear fuel. This is then followed by recommended safety practices and then sections on film handling, film processing, viewing of radiographs, references, radiographs, storage and records. Recommendations on training and certification are being prepared. It does not include any technical justification for the practices which are recommended. (Auth.)

  1. Compton radiography, 1

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Sera, Koichiro; Fukuda, Hiroshi; Shishido, Fumio; Matsuzawa, Taiju

    1977-01-01

    Tomographic images of an object are obtainable by irradiating it with a collimated beam of monochromatic gamma rays and recording the resultant Compton rays scattered upward at right angles. This is the scattered-ray principle of the formation of a radiation image that differs from the traditional ''silhouette principle'' of radiography, and that bears prospects of stereopsis as well as cross-section tomography. (Evans, J.)

  2. Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages

    International Nuclear Information System (INIS)

    Sandborg, Michael; Tingberg, Anders; Ullman, Gustaf; Dance, David R.; Alm Carlsson, Gudrun

    2006-01-01

    The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography

  3. Reference dose levels for dental panoramic radiography in Gwangju (South Korea)

    International Nuclear Information System (INIS)

    Lee, J. S.; Kim, Y. H.; Yoon, S. J.; Kang, B. C.

    2010-01-01

    This study assessed the reference dose levels for dental panoramic radiography in Gwangju city (South Korea) based on the dose width product (DWP) and compared them with those already established elsewhere. A total of 44 panoramic dental radiographic sets (36 digital and 8 analogue panoramic sets) in 41 dental clinics in Gwangju city were chosen. The third quartile DWP was determined from 429 surface dose measurements of the adult surface dose in panoramic dental radiography. The third quartile DWP for panoramic radiography was 60.1 mGy mm. The proposed DWP reference levels of 60.1 mGy mm were less than or equal to those previously reported in other countries, such as Italy and UK, and acceptable for panoramic radiography in Gwangju (KR). (authors)

  4. Optimization of digital radiography techniques for specific application

    International Nuclear Information System (INIS)

    Harara, W.

    2010-12-01

    A low cost digital radiography system (DRS) for testing weld joints and castings in laboratory was assembled. The DRS is composed from X-ray source, scintillator, first surface mirror with Aluminum coating, charged coupled device (CCD) camera and lens. The DRS was used to test flawed carbon steel welded plates with thicknesses up to 12 mm. The comparison between the digital radiographs of the plates weldments and the radiographs of the same plates weldments using medium speed film type had shown that, the detection capability of the weld flaws are nearly identical for the two radiography techniques, while the sensitivity achieved in digital radiography of the plates weldments was one IQI wire less than the sensitivity achieved by conventional radiography of the same plates weldments according to EN 462-1. Further, the DRS was also successfully used to test (100 x 100 x 100) mm Aluminum casting with artificial flaws of varied dimensions and orientations. The resulted digital radiographs of the casting show that, all the flaws had been detected and their dimensions can be measured accurately, this confirm that, The proposed DRS can be used to detect and measure the flaws in the Aluminum and others light metals castings accurately. (author)

  5. Practical Uses of Neutron Radiography for Non-Destructive Testing

    International Nuclear Information System (INIS)

    Middleton, M.F.; de Beer, F.; Pazsit, Imre; Li, Kewen; Hilson, Jodie

    2006-01-01

    Over the past nine years, a research collaboration has been developed around the use of neutron radiography in non-destructive testing of porous rocks and other materials. This paper is a review of that work, with a critical reflection on the future potential of the technique. Neutrons are ideal for detecting water concentration, due to the high attenuation of neutrons by hydrogen, in porous or semi-porous media. Problems, which involve the determination of water concentration in porous media, are particularly amenable for neutron radiography analysis. In this context, water concentration in porous media is important in groundwater studies, petroleum reservoir studies, studies of geothermal systems, the understanding of water absorption in building materials, and more recently in mineral exploration and processing applications. Beyond these applications, neutron analysis of flawed and corroded aircraft parts has emerged as a valuable tool to support conventional non-destructive testing (NDT) techniques. Such investigations, using neutron radiography of aircraft parts, have been active in the United States, Canada and South Africa for over two decades. In 2001, an Australian Research Council (ARC) grant enabled the informal collaboration to establish a semi-portable neutron imaging system in Australia. Preliminary results of that ongoing research will also be presented herein. In overview, neutron radiography presents a powerful non-destructive testing method, which in many new areas of application remains to be evaluated. It has proven to be most valuable where water detection, in quantities greater than approximately 0.1 percent of the total volume, is required. This concentration is not a limitation on the technique, but only current applications. It has been demonstrated to be powerful tool to detect natural substances containing bound-water and neutron-attenuating minerals, such as clay, Glauconite and the various water-rich iron-bearing minerals (e.g. Goethite

  6. Shielding calculations for the design of neutron radiography facility around PARR

    International Nuclear Information System (INIS)

    Ashraf, M.M.; Khan, A.R.

    1989-06-01

    Shielding calculations for neutron radiography facility, proposed to be established around PARR have been carried out using two group diffusion theory and shielding formulae. Gamma radiation penetration calculations have been carried out using simple attenuation methods. The fabrication and installation of the neutron radiography facility would provide the basis for designing a better collimating system and would help establish under water radiography facility for the inspection of highly radioactive materials and components etc. (orig./A.B.)

  7. Acute Knee Trauma: Analysis of Multidetector Computed Tomography Findings and Comparison with Conventional Radiography

    International Nuclear Information System (INIS)

    Mustonen, A.O.T.; Kiuru, M.J.

    2005-01-01

    Purpose: To evaluate the multidetector computed tomography (MDCT) findings of acute knee trauma and to compare radiography with MDCT in patients referred ta level 1 trauma center. Material and Methods: During a 5-year period, a total of 415 MDCT examinations were performed on 409 patients with acute knee trauma to reveal complex fracture anatomy or rule out a fracture. MDCT and primary radiographs were re-evaluated with respect to fracture location and trauma mechanism. Tibial plateau fractures were further analyzed depending on anatomical location: anterior-medial, anterior-lateral, posterior-lateral, and posterior-medial regions. Maximal depression of the tibial articular surface was measured. Findings on the primary knee radiographs were compared with MDCT findings. Results: Of the 409 patients, 356 (87%) had a knee fracture. A total of 451 fractures were found in all anatomic regions: distal femur ( n = 49), proximal tibia ( n 307), patella ( n = 23), and proximal fibula ( n = 72). Primary radiographs were available in 316 (76%) cases. Of these, 225 (71%) had MDCT in order to reveal the fracture anatomy better, and 91 (29%) had a subsequent MDCT after negative plain radiographs. Overall sensitivity of radiography was 83%, while negative predictive value was 49%. On radiography, tibial plateau articular depression was underestimated in all regions except when the fracture consisted of the whole half of the anterior or posterior plateau. The three main injury mechanisms were traffic accident, a simple fall, and sport. In 49 cases (15%), primary radiographs were suboptimal due to positioning. Conclusion: In severely injured patients, diagnostically sufficient radiographs are difficult to obtain, and therefore a negative radiograph is not reliable in ruling out a fracture. In these patients, MDCT is a fast and accurate examination and is also recommended in patients with tibial plateau fractures or complex knee injuries in order to evaluate the fracture adequately

  8. The emergency department: An appropriate referral rate for radiography

    International Nuclear Information System (INIS)

    Richards, P.J.; Tins, B.; Cherian, R.; Rae, F.; Dharmarajah, R.; Phair, I.C.; McCall, I.

    2002-01-01

    AIM: To evaluate the hypothesis that where there is good clinical practice in an emergency department (ED), there is a low uptake of plain radiography. MATERIALS AND METHODS: Emergency notes and radiography records were reviewed over one week in January 1999, to determine the rate of radiography of first time attenders at the North Staffordshire NHS Trust. The clinical appropriateness of the imaging was assessed by pairs of radiology specialist registrars and casualty physicians. They judged the appropriateness of the imaging by the 1998 Royal College of Radiologists (RCR) guidelines and/or their clinical judgement, by consensus. Where there was no consensus or the data appeared incomplete, the radiology and ED consultant reviewed the notes. RESULTS: A total of 1615 notes were found out of 1643 (98%). Of these, 147 (9%) return attenders were excluded and 32 patients left without being seen. The number of first time attenders was 1436 (87%), of whom 637 (44%) were radiographed; 95% of these radiography examinations were appropriate and 5% were inappropriate. Of the first time attenders who were not radiographed the decision was appropriate in 95% of cases, and inappropriate for 5%, i.e. 5% of those who had no radiography, should have been X-rayed. There were no disagreements between RCR guidelines and the clinical judgements, but in 16% there were no suitable RCR guidelines. Junior doctors were not always able to find the relevant RCR guideline (relevant clinical guideline found in 73% of cases) in the guideline book, compared to the consultants (relevant clinical guideline found in 84% of cases). CONCLUSION: The application of the RCR guidelines is taken as representing good clinical practice in determining when to refer a patient for radiography. Based on this assumption, a referral rate for radiography of 44% of first time attenders was found to be appropriate. This referral rate can be taken as a benchmark. A benchmark is necessary in order to allow departments

  9. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  10. Mobile waste inspection real time radiography system

    International Nuclear Information System (INIS)

    Vigil, J.; Taggart, D.; Betts, S.; Rael, C.; Martinez, F.; Mendez, J.

    1995-01-01

    The 450-KeV Mobile Real Time Radiography System was designed and purchased to inspect containers of radioactive waste produced at Los Alamos National Laboratory (LANL). The Mobile Real Time Radiography System has the capability of inspecting waste containers of various sizes from 5-gal. buckets to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). The fact that this unit is mobile makes it an attractive alternative to the costly road closures associated with moving waste from the waste generator to storage or disposal facilities

  11. Supervision of radiography licensees - using electronic questionnaires

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Aa. [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2005-09-15

    The results from this questionnaire gave a general view of the state of the radiography practices in Sweden, and the questionnaire hopefully contributed to improve the knowledge of these regulations for the licensees. The largest deficiencies were found in the documentation of the radiation protection organisation as well as documentation of quality assurance and operational statistics. The results of the questionnaire constitute a useful basis for selecting companies for future inspections by SSI. Those who has not answered the questionnaire and are working with site radiography can expect a visit in the near future.

  12. Non-destructive test of lock actuator component using neutron radiography technique

    International Nuclear Information System (INIS)

    Juliyanti; Setiawan; Sutiarso

    2012-01-01

    Non-destructive test of lock actuator using neutron radiography technique has been done. The lock actuator is a mechanical system which is controlled by central lock module consisting of electronic circuit which drives the lock actuator works accordingly to open and lock the vehicle door. The non-destructive test using neutron radiography is carried out to identify the type of defect is presence by comparing between the broken and the brand new one. The method used to test the lock actuator component is film method (direct method). The result show that the radiography procedure has complied with the ASTM standard for neutron radiography with background density of 2.2, 7 lines and 3 holes was seen in the sensitivity indicator (SI) and the quite good image quality was obtained. In the brand new actuator is seen that isolator part which separated the coils has melted. By this non-destructive test using neutron radiography technique is able to detect in early stage the type of component's defect inside the lock actuator without to dismantle it. (author)

  13. An application of neutron radiography to archaeology

    International Nuclear Information System (INIS)

    Tugrul, B.

    1990-01-01

    Neutron radiography is more useful for certain materials than are the other radiographic techniques. Some neutrons are attenuated by light materials such as water, hydrocarbons and boron, but penetrate through heavy materials such as steel, lead and uranium. The object must be irradiated by neutrons for neutron radiography. The neutron irradiation can take place in a reactor or with a neutron source. The transfer technique relies on the build-up of radioactivity in a foil due to neutron absorption. In this way an activation image is formed in the foil. For this technique, dysprosium ( 164 Dy) and indium ( 115 In) foils can be used. After this irradiation, foils are transferred to a film in the dark-room, the latent image being formed in the film by decay radiation from the foil. The neutron radiography technique has been applied to a sword together with its sheath (inventory number 83/173) (Tugrul and Erdal 1987); a piece of cloth was visible on the handle of the sword. Sword and sheath had become corroded together. The artefact is from the Ikiztepe excavation near the city of Samsun in north Anatolia and belongs to the Early Bronze Age. First, X-ray radiography showed that the sword had been destroyed in large part and was not suitable for conservation and restoration procedures. Second, neutron radiography was carried out. Dysprosium-164 was used for the transfer method as a foil screen and irradiated in the reactor at 100 kW for half an hour. The dysprosium foil remained against the radiographic (Structurix, D-7) film for approximately three half-lives after the irradiation. The neutron radiograph shows the cloth layer continuing towards the bottom of the sheath. Through the cloth, water would have been introduced to the inside of the sheath and this was the main cause of corrosion to the artefact and so of the sword's destruction. (author)

  14. A survey of sub-specialty preferences of radiography students of the University of Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    E T Namah

    2013-01-01

    Full Text Available Background: Technological advances and computing have expanded both the scope and capacity of diagnostic medical imaging (the radiography profession. This has created many diverse imaging modalities which in turn, have culminated in different sub-specialties in the profession. Objective: The aims of the study were to determine the level of awareness of imaging sub-specialties, preferred sub specialties and reasons for preferences of sub-specialties in senior level radiography students of the University of Lagos. Methods: The study was a prospective cross-sectional survey. Consents were obtained before the students were recruited for the study. Data Collection and Analysis: A questionnaire semi-structured in line with objectives of the study was used in data collection. A computer software Epi Info version 3.3 was used to analyze data while results were expressed as percentages of responses and were presented in tables and pie charts. Results : Greater than 90% showed awareness of sub-specialties in the radiography profession whereas 35% preferred ultrasonography to other sub-specialties. The least preferred sub-specialty was conventional radiography (4.3%. Remuneration (73.3% and less physical exertion (73.3% were major attractors to preferred sub-specialties whereas concerns over radiation hazard were major detractors (58.3%. Conclusion : Awareness of sub-specialties in the radiography profession was high amongst students studied. Furthermore, ultrasonography was the most preferred sub-specialty among the respondents. Remuneration was the main attractor to sub-specialties whereas fears over effects of ionizing radiation were the major detractors to some sub-specialties.

  15. Analysis of hydrogen content and distribution in hydrogen storage alloys using neutron radiography

    International Nuclear Information System (INIS)

    Sakaguchi, Hiroki; Hatakeyama, Keisuke; Satake, Yuichi; Esaka, Takao; Fujine, Shigenori; Yoneda, Kenji; Kanda, Keiji

    2000-01-01

    Small amounts of hydrogen in hydrogen storage alloys, such as Mg 2 Ni, were detected using neutron radiography (NRG). Hydrogen concentrations in a hydrogenated solid solution were determined by this technique. Furthermore, we were able to obtain NRG images for an initial stage of hydrogen absorption in the hydrogen storage alloys. NRG would be a new measurement method to clarify the behavior of hydrogen in hydrogen storage alloys. (author)

  16. Information-theoretical analysis of private content identification

    NARCIS (Netherlands)

    Voloshynovskiy, S.; Koval, O.; Beekhof, F.; Farhadzadeh, F.; Holotyak, T.

    2010-01-01

    In recent years, content identification based on digital fingerprinting attracts a lot of attention in different emerging applications. At the same time, the theoretical analysis of digital fingerprinting systems for finite length case remains an open issue. Additionally, privacy leaks caused by

  17. Z-petawatt driven ion beam radiography development.

    Energy Technology Data Exchange (ETDEWEB)

    Schollmeier, Marius; Geissel, Matthias; Rambo, Patrick K.; Schwarz, Jens; Sefkow, Adam B.

    2013-09-01

    Laser-driven proton radiography provides electromagnetic field mapping with high spatiotemporal resolution, and has been applied to many laser-driven High Energy Density Physics (HEDP) experiments. Our report addresses key questions about the feasibility of ion radiography at the Z-Accelerator (%E2%80%9CZ%E2%80%9D), concerning laser configuration, hardware, and radiation background. Charged particle tracking revealed that radiography at Z requires GeV scale protons, which is out of reach for existing and near-future laser systems. However, it might be possible to perform proton deflectometry to detect magnetic flux compression in the fringe field region of a magnetized liner inertial fusion experiment. Experiments with the Z-Petawatt laser to enhance proton yield and energy showed an unexpected scaling with target thickness. Full-scale, 3D radiation-hydrodynamics simulations, coupled to fully explicit and kinetic 2D particle-in-cell simulations running for over 10 ps, explain the scaling by a complex interplay of laser prepulse, preplasma, and ps-scale temporal rising edge of the laser.

  18. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik

    ,3 mAs and SID SID of 180 centimetres using a phantom and lithium fluoride thermo luminescence dosimeter (TLD). Dose to risk organs mamma, thyroid and colon are measured at different collimations with one-centimetre steps. TLD results are used to estimate dose reduction for different collimations...... at the conference. Conclusion: Collimation improvement in basic chest radiography can reduce the radiation to female patients at chest x-ray examinations....

  19. A spectrometric approach in radiography for detection of materials by their effective atomic number

    CERN Document Server

    Ryzhikov, V D; Onyshchenko, G M; Lecoq, P; Smith, C F

    2009-01-01

    In this paper we report a spectrometric approach to dual-energy digital radiography that has been developed and applied to identify specific organic substances and discern small differences in their effective atomic number. An experimental setup has been designed, and a theoretical description proposed based on the experimental results obtained. The proposed method is based on the application of special reference samples made of materials with different effective atomic number and thickness parameters known to affect X-ray attenuation in the low-energy range. The results obtained can be used in the development of a new generation of multi-energy customs or medical X-ray scanners.

  20. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  1. Investigation of radiation exposure dosage in dental and panoramic radiography

    International Nuclear Information System (INIS)

    Ishii, Kenichi

    2005-01-01

    Dental radiography and a 10-sheet procedure were conducted at 10 sites in the maxillomandibular anterior teeth and at both sides of the premolar and molar teeth sections with and without a protective apron (total 22 patterns). Experiments, which included a total of five patterns, involving standard ortho-radiography were performed with and without a protective apron, positioning of an apron exclusively on the anterior or the posterior portion of the body and utility of an apron that covered the entire body. Results are as follows: In dental radiography, internal organs included in a bundle demonstrated high radiation exposure, whereas organs excluded from the bundle exhibited low radiation exposure. In organs situated below the thyroid gland, utilization of aprons resulted in lower radiation exposure. In ortho-radiography, radiation exposure was greatest in the parotid gland, followed by the mandibular, sublingual and thyroid glands, respectively. The protective apron resulted in lower radiation exposure at sites situated below the mammary glands; moreover, a protector covering the entire body led to lower radiation exposure in comparison to an apron worn exclusively on the anterior or the posterior aspect of the body. No significant difference was observed in terms of exposure between protective aprons worn on the anterior or the posterior aspect of the body. Furthermore, a protective collar resulted in nearly zero radiation exposure in the thyroid gland. However, a protective collar largely interferes with interpretation of the radiograph; thus, in order to produce interpretable radiographs, protection of the thyroid gland is not possible. In conclusion, radiation exposure dosage can be reduced via utilization of a protective apron positioned below the thyroid gland during dental radiography and below the mammary glands during ortho-radiography. We confirmed evidence indicating that application of a protective apron can reduce patient radiation exposure dosage

  2. Marginal Assessment of Crowns by the Aid of Parallel Radiography

    Directory of Open Access Journals (Sweden)

    Farnaz Fattahi

    2015-03-01

    Full Text Available Introduction: Marginal adaptation is the most critical item in long-term prognosis of single crowns. This study aimed to assess the marginal quality as well asthe discrepancies in marginal integrity of some PFM single crowns of posterior teeth by employing parallel radiography in Shiraz Dental School, Shiraz, Iran. Methods: In this descriptive study, parallel radiographies were taken from 200 fabricated PFM single crowns of posterior teeth after cementation and before discharging the patient. To calculate the magnification of the images, a metallic sphere with the thickness of 4 mm was placed in the direction of the crown margin on the occlusal surface. Thereafter, the horizontal and vertical space between the crown margins, the margin of preparations and also the vertical space between the crown margin and the bone crest were measured by using digital radiological software. Results: Analysis of data by descriptive statistics revealed that 75.5% and 60% of the cases had more than the acceptable space (50µm in the vertical (130±20µm and horizontal (90±15µm dimensions, respectively. Moreover, 85% of patients were found to have either horizontal or vertical gap. In 77% of cases, the margins of crowns invaded the biologic width in the mesial and 70% in distal surfaces. Conclusion: Parallel radiography can be expedient in the stage of framework try-in to yield some important information that cannot be obtained by routine clinical evaluations and may improve the treatment prognosis

  3. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  4. Image quality in conventional chest radiography. Evaluation using the postprocessing tool Diamond View

    International Nuclear Information System (INIS)

    Niemann, Tilo; Reisinger, Clemens; Rau, Philipp; Schwarz, Jochen; Ruis-Lopez, Laura; Bongartz, Georg

    2010-01-01

    The objective of this work was to evaluate the influence of the postprocessing tool Diamond View (Siemens AG Medical Solutions, Germany) on image quality in conventional chest radiography. Evaluation of image quality remains a challenge in conventional radiography. Based on the European Commission quality criteria we evaluated the improvement of image quality when applying the new postprocessing tool Diamond View (Siemens AG Medical solutions, Germany) to conventional chest radiographs. Three different readers prospectively evaluated 102 digital image pairs of chest radiographs. Statistical analysis was performed with a p value <0.05 considered as significant. Images were evaluated on basis of the modified imaging Quality Criteria by the Commission of the European Communities. Each of the 11 image quality criteria was evaluated separately using a five point classification. Statistical analysis showed an overall tendency for improved image quality for Diamond View (DV) for all criteria. Significant differences could be found in most of the criteria. In conclusion DV improves image quality in conventional chest radiographs.

  5. LANL12-RS-107J PYTHON Radiography Analysis Tool (PyRAT). Mid-Year Deliverable Report for FY15

    International Nuclear Information System (INIS)

    Temple, Brian Allen; Armstrong, Jerawan Chudoung

    2015-01-01

    This document is a mid-year report on a deliverable for the PYTHON Radiography Analysis Tool (PyRAT) for project LANL12-RS-107J in FY15. The deliverable is deliverable number 2 in the work package and is titled ''Add the ability to read in more types of image file formats in PyRAT''. Right now PyRAT can only read in uncompressed TIF files (tiff files). It is planned to expand the file formats that can be read by PyRAT, making it easier to use in more situations. A summary of the file formats added include jpeg, jpg, png and formatted ASCII files.

  6. Proton Radiography: Cross Section Measurement and Detector Development

    International Nuclear Information System (INIS)

    Longo, Michael J.

    2007-01-01

    Proton radiography offers significant advantages over conventional X-ray radiography, including the capability of looking into thick, dense materials, better contrast for a wide range of materials, sensitivity to different materials of similar density, and better resolution because of the ability to focus beams. In order to achieve this capability it is crucial to understand the background due to neutrons and photons and to develop techniques to reduce it to tolerable levels. The physics goal of this project is to measure forward production of neutrons and photons produced by high-energy proton beams striking a variety of targets. This work is being carried out in conjunction with the Fermilab Experiment 907 (MIPP) collaboration including physicists from Lawrence Livermore Laboratory. Our group is responsible for the E907 forward neutron/photon calorimeters. These are the only detectors in the experiment that provide information on neutrons and photons. We are taking a leading role in obtaining and analyzing the for-ward production data and in developing an optimal detector for proton radiography. With the support of our Stewardship Science Academic Alliances grant, we were able to design, build, and commission the calorimeters on budget and ahead of schedule. E-907 officially started physics running at Fermilab in January 2005, and data taking continued through February 2006. Data were taken on a range of targets, from liquid hydrogen to uranium, at beam energies from 5 GeV/c to 120 GeV/c. The analysis of the data is challenging because data from many different detector systems must be understood and merged and over 31 million events were accumulated. Our recent efforts have been devoted to the calibration of the neutron and photon detectors, to track and shower reconstruction, identification of forward-going neutrons, and simulation of the calorimeters in a Monte Carlo. Reconstruction of the data with improved tracking is underway

  7. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  8. Radiation protection in technical radiography

    International Nuclear Information System (INIS)

    Thiele, H.

    1980-01-01

    In on-site inspections, e.g. double-plate radiography of circumferential pipe welds Ir-192 is most frequently used. Methods, controlled area, possible personnel doses, and radiation protection measures for the inspection and construction personnel are briefly discussed. (HP) [de

  9. Neutron radiography in Brazil

    International Nuclear Information System (INIS)

    Rogers, J.D.

    1983-01-01

    Neutron radiography studies being carried out in reactor centres in Brazil are discussed. These research projects are under way using the 5 MW swimming pool reactor at the Institute of Energy and Nuclear Research (IPEN) in Sao Paulo and the Argonaut reactor at the Institute of Nuclear Engineering (IEN) in Rio de Janeiro. (Auth.)

  10. Short-Term changes on MRI predict long-Term changes on radiography in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Peterfy, Charles; Strand, Vibeke; Tian, Lu

    2017-01-01

    Objective In rheumatoid arthritis (RA), MRI provides earlier detection of structural damage than radiography (X-ray) and more sensitive detection of intra-Articular inflammation than clinical examination. This analysis was designed to evaluate the ability of early MRI findings to predict subsequent...

  11. Radiologic analysis of femoral acetabular impingement: from radiography to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dwek, Jerry R. [University of California at San Diego, Department of Radiology, Rady Children' s Hospital and Health Center, San Diego, CA (United States); San Diego Imaging, San Diego, CA (United States); Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Chung, Christine B. [University of California at San Diego, Department of Radiology, San Diego, CA (United States)

    2013-03-15

    Femoral acetabular impingement is a set of morphologic abnormalities that are considered to be a major cause of degenerative disease in the hip joint. Early changes are already present in adolescence when it is the pediatric radiologist who must assess current damage with the aim of averting progression to more severe and debilitating osteoarthritis. A multimodality approach is used for diagnosis, that includes conventional radiography and CT to assess the osseous structures. MR arthrography is the primary advanced imaging modality for assessment of morphologic changes as well as injuries of the labrum and articular cartilage. Details of radiologic imaging are offered to guide the radiologist and provide an avenue for the accurate description of the osseous and articular alterations and injury. (orig.)

  12. Low cost automatic cable winder for industrial radiography projector

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Abdul Nassir Ibrahim; Shaharudin Sayuti; Glam Hadzir Patai Mohamad; Masrol Nizam Salleh; Arshad Yasin; Nur Aira Abdul Rahman

    2009-04-01

    Radiography is a well-established technique that is widely used to detect internal flaws in welds, castings and to check for misconstruction in assemblies. In general it is to verify weld quality in engineering structures such as the fabrication of pressure vessels, pipelines and storage tanks. It can be used on all metals, from light metals such as aluminium to dense metals such as lead. One of the techniques is industrial radiography projector. Industrial radiography projector is used to store radioactive materials when it is not required to expose the material under test. The projector will come together with a guide tube and control unit (cable winder and drive cable). When the source is to be used to radiograph an item, the cable winder will wind-out the source from projector to the desired location through a guide tube. Upon completion of the work the source will be retracted back into its safe shielded position in this projector. In common procedure, the operator has to be close to the exposures projector while wind-out or wind-in the source from and into the projector. This made the radiography operator receive the highest exposure among the radiation operator and this agreed by IAEA. This paper describes a winder cable that can be used to guide the movement of radiography source out of and into the projector that can be controlled by a remote control system. The system comprises of a gear, reversible motor and low frequency automatic controller. This system is powered by DC chargeable battery. (author)

  13. Reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications

    Directory of Open Access Journals (Sweden)

    Vilson Lacerda Brasileiro Junior

    2014-02-01

    Full Text Available Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57% patients. Such individuals presented with a total of 29 (41.43% carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50 of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001 was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.

  14. The quality assessment of radial and tangential neutron radiography beamlines of TRR

    International Nuclear Information System (INIS)

    Dastjerdi, M.H. Choopan; Movafeghi, A.; Khalafi, H.; Kasesaz, Y.

    2017-01-01

    To achieve a quality neutron radiographic image in a relatively short exposure time, the neutron radiography beam must be of good quality and relatively high neutron flux. Characterization of a neutron radiography beam, such as determination of the image quality and the neutron flux, is vital for producing quality radiographic images and also provides a means to compare the quality of different neutron radiography facilities. This paper provides a characterization of the radial and tangential neutron radiography beamlines at the Tehran research reactor. This work includes determination of the facilities category according to the American Society for Testing and Materials (ASTM) standards, and also uses the gold foils to determine the neutron beam flux. The radial neutron beam is a Category I neutron radiography facility, the highest possible quality level according to the ASTM. The tangential beam is a Category IV neutron radiography facility. Gold foil activation experiments show that the measured neutron flux for radial beamline with length-to-diameter ratio (L/D) =150 is 6.1× 10 6 n cm −2 s −1 and for tangential beamline with (L/D)=115 is 2.4× 10 4 n cm −2 s −1 .

  15. Immersion technique in soft tissue radiography of the hands

    International Nuclear Information System (INIS)

    Maekelae, P.; Haaslahti, J.O.

    1978-01-01

    Soft tissue radiography of hands using the technique of mammary radiography and immersion in a 2.5 cm layer of 1 : 1 water-ethanol solution is evaluated. Using immersion the average background density decreases with a factor of about 2.5 : 1, with little deterioration in resolution (MTF). The immersion procedure makes the demonstration and evaluation of soft tisse swelling and periarticular oedema easier. (Auth.)

  16. Radiography of Co-60 in the lead cube castings

    International Nuclear Information System (INIS)

    Djoli Soembogo; Harun Al Rasyid R; Namad Sianta

    2016-01-01

    Radiography Co-60 on Carbon steel or Stainless steel has been widely applied, but for metal Lead has not yet been applied and has not yet widely known. Lead has a greater density than Carbon steel or Stainless steel and could muffle gamma radiation so it takes a longer exposure time. The result of its film radiography are also not as good as compared to radiography applications on carbon steel or Stainless steel. The study also applied digital radiography using isotope Co-60 sources and used Epson V700 scanner positive film for digitization results of conventional radiographic films. These radiographs using film AGFA D7 to get the contrast medium, medium sensitivity and good image quality. The purpose of radiography Co-60 on the cube castings Lead is to find indications of defective castings cube Lead and digitizing the results using conventional radiographic film with a positive film media scanner to process the data transfer and storage of digital data. Radiographic testing has been carried out using the isotope Co-60 on metal castings Lead with a single thickness of a single shadow method using positive film scanner media and isotope Co-60 with disabilities observation parameter Lead metal castings on radiographic film. Co-60 radiation time exposure is 3,500 hours for the thickness of the metal cube castings Lead 100 mm with the activity of 29 Ci and perpendicular SFD of 840 mm. Radiographic testing on metal cube castings Lead by the method of a single thickness of single image defects produce a parameter indicative for a cube of metal castings Lead of porosity level 2. The density mean of radiographic film was 2.051 and 2.046 for 5 minutes in a developer solution. The result of scanning positive film is in the form of digital radiography which allows for the transfer of digital data or computerized storage of digital data. This status is still within limits acceptable under the standards referred. (author)

  17. Non destructive testing and neutron radiography in 1994

    International Nuclear Information System (INIS)

    Bayon, G.

    1994-01-01

    Neutron radiography has been considered for a long time as a promising technique; however it plays a minor part in the world of non destructive testing today, due to the lack of suitable neutron sources and lack of new industrial applications. This paper reviews the present status of neutron sources, neutron radiography activities, especially in France (such as the neutron-capture-issued secondary radiation spectrometry), in nuclear, aerospace, aeronautical and metallurgical sectors, and the last applications of neutron dynamic imaging. 9 refs

  18. Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography

    International Nuclear Information System (INIS)

    Gondo, Gakuji; Ishiwata, Yusuke; Yamashita, Toshinori; Iida, Takashi; Moro, Yutaka

    1989-01-01

    Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography (CR) are discussed. Computed radiography is a digital radiography system in which an imaging plate is used as an X-ray detector and a final image is displayed on the film. In the angiograms performed with CR, the spatial frequency components can be enhanced for the easy analysis of fine blood vessels. Computed radiography has an automatic sensitivity and a latitude-setting mechanism, thus serving as an 'automatic camera.' This mechanism is useful for radiography with a mobile X-ray unit in hospital wards, intensive care units, or operating rooms where the appropriate setting of exposure conditions is difficult. We applied this mechanism to direct percutaneous carotid angiography and intravenous digital subtraction angiography with a mobile X-ray unit. Direct percutaneous carotid angiography using CR and a mobile X-ray unit were taken after the manual injection of a small amount of a contrast material through a fine needle. We performed direct percutaneous carotid angiography with this method 68 times on 25 cases from August 1986 to December 1987. Of the 68 angiograms, 61 were evaluated as good, compared with conventional angiography. Though the remaining seven were evaluated as poor, they were still diagnostically effective. This method is found useful for carotid angiography in emergency rooms, intensive care units, or operating rooms. Cerebral venography using CR and a mobile X-ray unit was done after the manual injection of a contrast material through the bilateral cubital veins. The cerebral venous system could be visualized from 16 to 24 seconds after the beginning of the injection of the contrast material. We performed cerebral venography with this method 14 times on six cases. These venograms were better than conventional angiograms in all cases. This method may be useful in managing patients suffering from cerebral venous thrombosis. (J.P.N.)

  19. Detectability of the mediastinal lines : comparison of conventional film-screen radiography and digital radiography

    International Nuclear Information System (INIS)

    Shin, Hye Young; Park, Kyung Joo; Kang, Doo Kyung; Lee, Kang Lai; Han, Chaing Jin; Suh, Jung Ho

    1998-01-01

    Using dynamic range compression (DRC) processing, this study compared the detectability of mediastinal lines by conventional film screen radiography (FS) and by storage phosphor digital radiography (DR). We selected 200 normal consecutive chest radiographs (100 FS, 100 DR); dynamic range compression was applied to DR processing and moving grids were used in both systems. Seven mediastinal lines (left paraspinal, right paraspinal, azygoesophageal, left para-aortic, posterio junctional, anterior junctional and right paratracheal) were scored from 0 point to 3 point (0: not visible, 1 : suspiciously visible, 2 : visible, but not clear, 3: clearly visible) according to visibility and sharpness, as agreed by a radiologist and a resident. The differences between the two modalities were compared and analyzed by chi-square test. DR processed with DRC visualizes mediastinal lines more frequently and clearly than conventional FS, and is therefore thought to be useful for the evaluation of mediastinal diseases. (author). 14 refs., 2 tabs., 2 figs

  20. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition); Seguridad radiologica en la radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-12-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.