WorldWideScience

Sample records for radiographs

  1. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  2. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  3. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  4. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  5. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  6. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  7. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  8. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  9. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  10. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  11. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  12. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  13. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  14. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  15. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  16. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  17. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  18. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  19. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  20. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  1. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  2. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  3. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  4. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  5. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  6. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  7. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  8. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  9. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  10. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  11. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  12. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  13. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  14. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  15. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  16. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  17. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  18. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  19. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  20. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  1. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  2. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  3. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  4. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  5. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  6. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  7. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  8. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  9. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  10. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  11. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  12. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  13. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  14. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  15. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  16. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  17. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  18. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  19. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  20. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  1. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  2. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  3. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  4. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  5. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  6. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  7. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  8. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  9. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  10. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  11. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  12. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  13. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  14. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  15. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  16. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  17. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  18. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  19. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  20. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  1. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  2. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1988-01-01

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  3. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  4. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H; Brostroem, L A; Aparisi, T

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  5. Computational simulation of radiographic film

    International Nuclear Information System (INIS)

    Goncalves, Elicardo A. de S.; Santos, Marcio H. dos; Anjos, Marcelino J.; Oliveira, Luis F. de

    2013-01-01

    The composition of a radiographic film gives its values of speed, spatial resolution and base density. The technical knowledge allows to predict how a film with a known composition works, and simulate how this film will work with changes in composition and exposure. In this paper, characterization of films composed by different emulsions was realized, in a way to know the characteristic curve, and to study how the format, organization and concentration of silver salt crystals set the radiographic film images.This work aims to increase an existing simulator, where parallel programming was used to simulate X-ray fluorescence processes. The setup of source and X-ray interactions with objects stills the same, and the detector constructed in this work was placed to form images. At first, considering the approach that the film is a square matrix where each element has a specific quantity of silver grains, that each grain fills a specific area, and that each interaction to radiation transforms a salt silver grain in to metallic silver grain (black grain), we have a blackening standard, and it should show how is the behavior of a optic density in a specific area of the film. Each matrix element has a degree of blackening, and it is proportional to the black grains area. (author)

  6. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  7. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  8. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  9. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  10. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  11. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  12. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  13. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  14. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  15. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)

  16. Radiographic study of the odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Hyung Kyu [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1983-11-15

    The author studied clinically and radiologically 55 cases which had been diagnosed as odontoma in SNUDH. The obtained results were as follows: 1. In sex distribution, there was no prevalence in both sexes. And the incidence was the highest in the 2nd decade (16 patient, 29%). 2. There were 42 cases of compound odontoma (76%) and 13 cases of complex odontoma (24%). In most cases, compound odontoma was located at the anterior portion (34 cases, 81%) and complex odontoma at the posterior portions (9 cases, 69%). 3. There was no apparent clinical symptom in compound odontoma (83%), but in complex odontoma, 80% of cases show swelling. 4. The adjacent root resorption was not observed in any case. 5. Five cases radiographically diagnosed as cystic odontoma were not confirmed histopathologically.

  17. Radiographic inspection on offshore platforms

    International Nuclear Information System (INIS)

    Soares, Sergio Damasceno; Sperandio, Augusto Gasparoni

    1994-01-01

    One of the great challenges for non-destructive inspection is on offshore platforms, where safety is a critical issue. Inspection by gammagraphy is practically forbidden on the platform deck due to problems to personnel safety and radiological protection. Ir-192 sources are used and the risk of an accident with loss of radioisotope must be considered. It is unfeasible to use gammagraphy, because in case of an accident the rapid evacuation from the platform would be impossible. This problem does not occur when X-ray equipment is used as the radiation source. The limited practicality and portability of the X-ray equipment have prevented its use as a replacement for the gammagraphy. This paper presents the preliminary tests to see the viable use of radiographic tests with constant potential on offshore platforms. (author). 2 refs., 1 fig., 2 tabs, 3 photos

  18. Radiographic evaluation of hallux valgus

    International Nuclear Information System (INIS)

    Richardson, M.L.; Hansen, S.T.; Kilcoyne, R.F.

    1987-01-01

    This paper presents the common preoperative and postoperative findings in hallux valgus, a common foot disorder of multiple etiologies, which can lead to significant foot pain and deformity. Little has been published in radiologic literature about the proper initial radiographic workup and the postoperative follow-up of this very common and very treatable cause of foot pain. Besides the primary findings of varus angulation of the first metatarsal and valgus angulation of the great toe, one may also see dorsal slaying of the first metatarsal head. As increased weight is borne by the central metatarsals, they may develop hyperostosis and stress fractures. Angular deformities of the hallux sesamoid joint and lesser toes may also be seen

  19. Glass Foreign Body Hand Radiograph

    Directory of Open Access Journals (Sweden)

    Hamid Ehsani-Nia, DO

    2018-04-01

    Full Text Available History of present illness: A 27-year-old female sustained an injury to her left hand after she tripped and fell on a vase. She presented to the emergency department (ED complaining of pain over the laceration. Upon examination, patient presented with multiple small abrasions of the medial aspect of the left 5thdigit that are minimally tender. Additionally, she has one 0.5cm linear laceration of the medial aspect of the 5thmetacarpal with severe tenderness in the area and palpable underlying foreign body. Significant findings: Left hand plain radiography demonstrated a subcutaneous foreign body medial to the 5thmetacarpal that is radiopaque, trapezoidal in shape, and measures approximately 11mm x 3mm. Discussion: Laceration repairs are amongst the most common procedures in the emergency department; however, consideration for foreign body is often underdiagnosed. Imaging is performed in only about 11% of all traumatic wounds in the ED.1 Of those injuries relating to the hand that are subsequently imaged, about 15% are found to have a foreign body.2,3 Additionally, it is estimated that foreign bodies are present in 7% to 8.7% of all wounds caused by glass objects.4,5 Glass is among the most common foreign bodies in lacerations, and fortunately they are radiopaque and relatively well visualized radiographically. It has been demonstrated that 2mm glass foreign bodies have a 99% detection rate with radiography, and 1mm glass foreign bodies an 83% detection rate.6 Patient perception of foreign body has a positive predictive value of 31%, making it a poor source in influencing clinical decision-making to obtain wound radiographs.3 Clinicians should have a high suspicion for foreign body in lacerations, particularly those caused by glass, and utilize close physical examination and imaging for evaluation. Topics: Radiography, glass, foreign body, trauma

  20. Conversion into numerical form of radiographic images

    International Nuclear Information System (INIS)

    Cappabianca, C.; Della Rocca, A.B.; Ferriani, S.

    1986-01-01

    Radiographic means are widely used for non destructive testing. However, human and technological factors strongly influence reliability of the results and further use of these technique. Image Processing can help to overtake those difficulties if radiographic films are previously digitized. This paper shows methods and equipments used in this field. The system EDI (Enea Digital. Imagery) operating in Casaccia Energy Research Centre is described

  1. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  2. Digital interactive learning of oral radiographic anatomy.

    Science.gov (United States)

    Vuchkova, J; Maybury, T; Farah, C S

    2012-02-01

    Studies reporting high number of diagnostic errors made from radiographs suggest the need to improve the learning of radiographic interpretation in the dental curriculum. Given studies that show student preference for computer-assisted or digital technologies, the purpose of this study was to develop an interactive digital tool and to determine whether it was more successful than a conventional radiology textbook in assisting dental students with the learning of radiographic anatomy. Eighty-eight dental students underwent a learning phase of radiographic anatomy using an interactive digital tool alongside a conventional radiology textbook. The success of the digital tool, when compared to the textbook, was assessed by quantitative means using a radiographic interpretation test and by qualitative means using a structured Likert scale survey, asking students to evaluate their own learning outcomes from the digital tool. Student evaluations of the digital tool showed that almost all participants (95%) indicated that the tool positively enhanced their learning of radiographic anatomy and interpretation. The success of the digital tool in assisting the learning of radiographic interpretation is discussed in the broader context of learning and teaching curricula, and preference (by students) for the use of this digital form when compared to the conventional literate form of the textbook. Whilst traditional textbooks are still valued in the dental curriculum, it is evident that the preference for computer-assisted learning of oral radiographic anatomy enhances the learning experience by enabling students to interact and better engage with the course material. © 2011 John Wiley & Sons A/S.

  3. Consultant breast radiographers: Where are we now?

    International Nuclear Information System (INIS)

    Rees, Zebby

    2014-01-01

    Introduction: The aim of this study is to: • Evaluate the current role of the consultant breast radiographer. • Compare current practice with the four key components for consultant practice. • Gauge the support of radiologist colleagues. • Determine the other professional commitments involved with the role. This study could be the precursor for a macro study of all consultant radiographer practice in other specialities. Methodology: Methodology used was a comparative ethnographic study. Questionnaires to the 24 consultant breast radiographers currently in post, and consultant breast radiologists, who work with them, were conducted. Data collection was a qualitative thematic approach. Conclusion: Consultant breast radiographers provide high quality care to patients through excellent clinical practice, leadership and good communication. However, this study shows hospital Trusts emphasis for non medical consultants is for clinical practice first. Some radiologists are still a barrier to progression for consultant breast radiographers, and radiologists have a big influence in recruitment decisions. Consultant breast radiographer posts are well established, their numbers are increasing through recognition of the role and of their abilities and performance. Consultant breast radiographers state that becoming a consultant is the major achievement of their career, proving the Society of Radiographers' vision of the four-tier career structure has been well received by the radiography profession

  4. Equipment for fully automatic radiographic pipe inspection

    International Nuclear Information System (INIS)

    Basler, G.; Sperl, H.; Weinschenk, K.

    1977-01-01

    The patent describes a device for fully automatic radiographic testing of large pipes with longitudinal welds. Furthermore the invention enables automatic marking of films in radiographic inspection with regard to a ticketing of the test piece and of that part of it where testing took place. (RW) [de

  5. Radiographic arthrosis after elbow trauma: interobserver reliability.

    NARCIS (Netherlands)

    Lindenhovius, A.; Karanicolas, P.J.; Bhandari, M.; Ring, D.; Kampen, A. van; et al.,

    2012-01-01

    PURPOSE: This study measured observer variation in radiographic rating of elbow arthrosis. METHODS: Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  6. Automatic Cobb Angle Determination From Radiographic Images

    NARCIS (Netherlands)

    Sardjono, Tri Arief; Wilkinson, Michael H. F.; Veldhuizen, Albert G.; van Ooijen, Peter M. A.; Purnama, Ketut E.; Verkerke, Gijsbertus J.

    2013-01-01

    Study Design. Automatic measurement of Cobb angle in patients with scoliosis. Objective. To test the accuracy of an automatic Cobb angle determination method from frontal radiographical images. Summary of Background Data. Thirty-six frontal radiographical images of patients with scoliosis. Methods.

  7. Influence of radiographic contrast media on phagocytosis

    International Nuclear Information System (INIS)

    Rasmussen, F.; Georgsen, J.; Grunnet, N.; Aalborg Sygehus

    1988-01-01

    To evaluate the influence of radiographic contrast media (CM) on human polymorphonuclear leucocytes (PML), the ability of these cells to ingest latex particles after in vitro exposure to five different radiographic contrast media was investigated. All CM inhibited the phagocytic properties of PML. The inhibition was dose dependent. The inhibitory effect was partly due to hyperosmolality but CM specific inhibition was also evident. (orig.)

  8. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  9. Radiographic Arthrosis After Elbow Trauma: Interobserver Reliability

    NARCIS (Netherlands)

    Lindenhovius, Anneluuk; Karanicolas, Paul Jack; Bhandari, Mohit; Ring, David; Allan, Cristopher; Axelrod, Terry; Baratz, Mark; Beingessner, Daphne; Cassidy, Charles; Coles, Chad; Conflitti, Joe; Rocca, Gregory Della; van Dijk, C. Niek; Elmans, L. H. G. J.; Feibe, Roger; Frihagen, Frede; Gosens, Taco; Greenberg, Jeffrey; Grosso, Elena; Harness, Neil; van der Heide, Huub; Jeray, Kyle; Kalainov, David; van Kampen, Albert; Kawamura, Sumito; Kloen, Peter; McCormac, Bob; McKee, Michael; Page, Richard; Pesantez, Rodrigo; Peters, Anil; Petrisor, Brad; Poolman, Rudolf; Richardson, Martin; Seiler, John; Swiontkowski, Marc; Trumble, Thomas; Wright, Thomas; Zalavras, Charalampos; Zura, Robert

    2012-01-01

    Purpose This study measured observer variation in radiographic rating of elbow arthrosis. Methods Thirty-seven independent orthopedic surgeons graded the extent of elbow arthrosis in 20 consecutive sets of plain radiographs, according to the Broberg and Morrey rating system (grade 0, normal joint;

  10. Validity of radiographic assessment of ankylosis

    International Nuclear Information System (INIS)

    Stenvik, A.; Beyer-Olsen, E.; Aabyholm, F.; Haanaes, H.R.; Gerner, N.W.

    1990-01-01

    The accuracy and sensitivity of radiographic assessments of reactive processes in dental tissues were evaluated by comparison of radiographs and histologic sections. Experimental lesions inflicted on the roots of 10 monkey incisors had been observed by means of serially obtained radiographs over a period of 315 to 370 days. The material was used for evaluation of radiographic assessment of ankylosis. For comparative purposes, assessment of the experimental lesion penetrating to the pulp and periapical radiolucency was added. True and falsely positive or negative recordings formed the basis for calculation of the accuracy and sensitivity of the radiographic assessment. The sensitivity, or the obsevers ability to detect the actual changes, was high for pulp penetration, intermediate for inflammation, and low for ankylosis. 6 refs., 3 figs., 2 tabs

  11. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  12. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  13. Chest radiographic findings in acute paraquat poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Na, Gyeong Gyun; Lee, Mi Sook; Kim, Hee Jun; Sun, In O [Presbyterian Medical Center, Jeonju (Korea, Republic of)

    2016-01-15

    To describe the chest radiographic findings of acute paraquat poisoning. 691 patients visited the emergency department of our hospital between January 2006 and October 2012 for paraquat poisoning. Of these 691, we identified 56 patients whose initial chest radiographs were normal but who developed radiographic abnormalities within one week. We evaluated their radiographic findings and the differences in imaging features based on mortality. The most common finding was diffuse consolidation (29/56, 52%), followed by consolidation with linear and nodular opacities (18/56, 32%), and combined consolidation and pneumomediastinum (7/56, 13%). Pleural effusion was noted in 17 patients (30%). The two survivors (4%) showed peripheral consolidations, while the 54 patients (96%) who died demonstrated bilateral (42/54, 78%) or unilateral (12/54, 22%) diffuse consolidations. Rapidly progressing diffuse pulmonary consolidation was observed within one week on follow-up radiographs after paraquat ingestion in the deceased, but the survivors demonstrated peripheral consolidation.

  14. The radiographic acromiohumeral interval is affected by arm and radiographic beam position

    Energy Technology Data Exchange (ETDEWEB)

    Fehringer, Edward V.; Rosipal, Charles E.; Rhodes, David A.; Lauder, Anthony J.; Feschuk, Connie A.; Mormino, Matthew A.; Hartigan, David E. [University of Nebraska Medical Center, Department of Orthopaedic Surgery and Rehabilitation, Omaha, NE (United States); Puumala, Susan E. [Nebraska Medical Center, Department of Preventive and Societal Medicine, Omaha, NE (United States)

    2008-06-15

    The objective was to determine whether arm and radiographic beam positional changes affect the acromiohumeral interval (AHI) in radiographs of healthy shoulders. Controlling for participant's height and position as well as radiographic beam height and angle, from 30 right shoulders of right-handed males without shoulder problems four antero-posterior (AP) radiographic views each were obtained in defined positions. Three independent, blinded physicians measured the AHI to the nearest millimeter in 120 randomized radiographs. Mean differences between measurements were calculated, along with a 95% confidence interval. Controlling for observer effect, there was a significant difference between AHI measurements on different views (p<0.01). All pair-wise differences were statistically significant after adjusting for multiple comparisons (all p values <0.01). Even in healthy shoulders, small changes in arm position and radiographic beam orientation affect the AHI in radiographs. (orig.)

  15. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  16. Gamma radiographic exposure time indicator

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1979-01-01

    In industrial radiography, with the proper selection of source and film, the radiographic quality depends very much on the exposure time, which in turn depends upon the source strength and the source to film distance. Conventional methods to arrive at correct exposure time involve time consuming calculations and in these methods the knowledge of the above mentioned parameters is imperative. An instrument to determine the required exposure time has been developed which indicates exposure times in about 30 secs. This covers two commonly used gamma radiography sources, viz., 192 Ir and 60 Co and six commonly used radiography films of different speeds. Knowledge of source strength and source to film distance is not required with the use of this instrument. With a knowledge of the total exposure required by the film to give the required sensitivity and by the measurement of radiation level at the film location, the correct exposure time is determined. The radiation level is measured by placing a GM counter behind the radiographic specimen at the film location. To match the responses of the film and the GM counter, the counter is incorporated in a suitably designed probe. In this instruments, an integrator to integrate the GM-pulses and a constant current integrator (timer) are started simultaneously. The voltage at the GM-pulse integrator is compared with a preselected voltage, (selected on the basis of film type, source, source strength and order of object thickness) by a comparator. The comparator is so adjusted that when the GM-pulse integrator voltage exceeds the preselected voltage, it switches its state and stops the integration of constant current. The constant current integrator output which is proportional to the time taken for the GM-pulse integrator to reach the preselected voltage, is read on a meter graduated in terms of exposure time. The instrument can measure exposure times from 5 minutes to 10 hours read in two ranges, the range-changing being automatic

  17. Reporting by radiographers: a policy and practice guide

    International Nuclear Information System (INIS)

    Paterson, Audrey M.; Price, Richard C.; Thomas, Adrian; Nuttall, Lorraine

    2004-01-01

    Reporting by radiographers and other non-medical staff has developed considerably in the past decade, and especially so since the College of Radiographers published its vision paper on reporting by radiographers, in 1997. It was felt necessary, therefore, to develop guidance to assist radiographers and others undertaking radiographic reporting. The guidance provided includes guidance on planning and implementing a reporting service using reporting radiographers; the education, continuing education and support required by reporting radiographers; quality and standards related to reporting; and the nature of a report. Broader issues that will need to be addressed as reporting by radiographers becomes the norm are also raised

  18. Agreement between radiographic and photographic trabecular patterns

    International Nuclear Information System (INIS)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der; Spruijt, R.J.; Mosekilde, L.

    1998-01-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach's α>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  19. Agreement between radiographic and photographic trabecular patterns

    Energy Technology Data Exchange (ETDEWEB)

    Korstjens, C.M.; Geraets, W.G.M.; Stelt, P.F. van der [Dept. of Oral Radiology, Academic Centre for Dentistry, Amsterdam (Netherlands); Spruijt, R.J. [Div. of Psychosocial Research and Epidemiology, Netherlands Cancer Inst., Amsterdam (Netherlands); Mosekilde, L. [Dept. of Cell Biology, Univ. of Aarhus (Denmark)

    1998-11-01

    Purpose: It has been hypothesized that photographs can facilitate the interpretation of the radiographic characteristics of trabecular bone. The reliability of these photographic and radiographic approaches has been determined, as have various agreements between the two approaches and their correlations with biomechanical characteristics. Material and Methods: Fourteen vertebral bodies were obtained at autopsy from 6 women and 8 men aged 22-76 years. Photographs (n=28) and radiographs (n=28) were taken of midsagittal slices from the third lumbar vertebra. The radiographs and photographs were digitized and the geometric properties of the trabecular architecture were then determined with a digital images analysis technique. Information on the compressive strength and ash density of the vertebral body was also available. Results: The geometric properties of both radiographs and photographs could be measured with a high degree of reliability (Cronbach`s {alpha}>0.85). Agreement between the radiographic and photographic approaches was mediocre as only the radiographic measurements showed insignificant correlations (p<0.05) with the biomechanical characteristics. We suggest that optical phenomena may result in the significant correlations between the photographs and the biomechanical characteristics. Conclusion: For digital image processing, radiography offers a superior description of the architecture of trabecular bone to that offered by photography. (orig.)

  20. Radiographic markers - A reservoir for bacteria?

    International Nuclear Information System (INIS)

    Tugwell, Jenna; Maddison, Adele

    2011-01-01

    Introduction: Amongst the most frequently handled objects in the radiology department are radiographic markers. They are personal accessories used with every patient, and are kept in the radiographers pockets when not utilised. Upon enquiry it was discovered that many radiographers disregarded the potential of these accessories to become a vector for cross-contamination thus never or rarely clean them. The aims of this study were therefore to identify if radiographic markers are a reservoir for bacteria and to establish an effective cleaning method for decontaminating them. Methodology: 25 radiographers/student radiographers were selected for this study. Swabbing of their markers prior and post cleaning took place. The microbiology laboratory subsequently analyzed the results by quantifying and identifying the bacteria present. The participants also completed a closed questionnaire regarding their markers (e.g. frequency of cleaning and type of marker) to help specify the results gained from the swabbing procedure. Results: From the sample swabbed, 92% were contaminated with various organisms including Staphylococcus and Bacillus species, the amount of bacteria present ranged from 0 to >50 CFU. There were no significant differences between disinfectant wipes and alcohol gel in decontaminating the markers. Both successfully reduced their bacterial load, with 80% of the markers post cleaning having 0 CFU. Conclusion: The results indicated that radiographic markers can become highly contaminated with various organisms thus serve as a reservoir for bacteria. In addition, the markers need to be cleaned on a regular basis, with either disinfectant wipes or alcohol gel to reduce their bacterial load.

  1. Radiographers and trainee radiologists reporting accident radiographs: A comparative plain film-reading performance study

    International Nuclear Information System (INIS)

    Buskov, L.; Abild, A.; Christensen, A.; Holm, O.; Hansen, C.; Christensen, H.

    2013-01-01

    Aim: To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital. Materials and methods: Plain radiographs of the appendicular skeleton from 1000 consecutive emergency room patients were included in the study: 500 primarily reported by radiographers and 500 by trainee radiologists. The final reporting was subsequently undertaken by a consultant radiologist in consensus with an orthopaedic surgeon. Two observers classified reports as either true positive/negative or false positive/negative based on the final report, which was considered the reference standard. To evaluate the severity of incorrect primary reports, errors were graded into three categories concerning clinical impact and erroneous reports graded as the most severe category were subsequently analysed. Mann–Whitney and Chi-squared tests were used to compare differences and associations between radiographers versus trainee radiologists regarding film reporting. Results: The sensitivity for correct diagnosis was 99% for reporting radiographers and 94% for trainee radiologists. The specificity was found to be 97% for reporting radiographers and 99% for trainee radiologists. Radiographers missed significantly fewer fractures (n = 2) than trainee radiologists (n = 14; p = 0.006) but had a higher, but not significant, degree of overcalling. No significant difference was found between groups regarding clinical impact of incorrect reporting. Conclusion: Trained radiographers report accident radiographs of the extremities with high accuracy and constitute a qualified resource to help meet increasing workload and demands in quality standards.

  2. Unicystic Jaw Lesions: A Radiographic Guideline

    Directory of Open Access Journals (Sweden)

    Giju George

    2010-01-01

    Full Text Available The unilocular radiolucencies remain the topic of much interest for the clinicians and histhopathologists for decades. Adequate use of diagnostic aids and careful observation will clinically help the dentist to arrive at a proper diagnosis and renders quality treatment to patients. Despite of the development of various cross-sectional imaging modalities, the radiograph still remains as the first and most important investigation. Jaw bone lesions, especially unilocular ones, are difficult to diagnose radiologically because of their similar radiographic appearance. It is, thus, very important for the clinician to have a sound knowledge of various radiographic features of the tooth and its supporting structures.

  3. A case of a found radiographic source

    International Nuclear Information System (INIS)

    Pucelj, B.; Korun, M.; Kavsek, D.; Kreft, Z.; Krizman, M.; Martincic, R.; Rosman, M.; Sutej, T.

    1996-01-01

    High dose-rate levels were detected outdoors in the vicinity of a bunker used for storage of radiographic sources in a plant which manufactures metallic products. The investigation revealed that radiation was due to a buried sealed radiographic source, containing 28 GBq of 137 Cs. A special republic radiological emergency team removed the source in a carefully planned operation. There was no evidence for overexposure of the population or of radiographic and other workers of the plant. The highest dose to the recovery team was 50 μSv

  4. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  5. Radiographic observation for tuberculous spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Se; Jung, Marn Kyoon; Kim, Byung Soo [College of Medicine, Busan National University, Busan (Korea, Republic of)

    1974-04-15

    Radiographic observation of 152 cases of tuberculous spondylitis selected from total 194 cases of tuberculous arthritis during the past 6 years and 8 months, was carried out to study. 1. The youngest one was 15 months old male infant of active tuberculous spondylitis. The active tuberculous spondylitis under 10 years of age were 50 percent (28 cases). 2. The ratio of male to female was 1.5:1 3. The most common site of involvement was the lumbar spine which was 44.1 percent of the total tuberculous spondylitis. The next were thoracic spine (33.6%), and thoraco-lumber spine (13.1%). 4. The most common roentgenographic findings are bony destructions of the vertebral bodies which were 97.4 percent. The next were joint space narrowing (93.4%), osteoporosis (79.6%), kyphosis (34.2%), fusion deformity of the vertebral body (25.7%), and cold abscess shadow (16.4%). 5. The most of patients (88.8%) had or have been pulmonary tuberculous lesions. 6. In annual incidence, the number of patients were not changed greatly.

  6. Radiographic evaluation of AIDS patients

    International Nuclear Information System (INIS)

    Le Blang, S.D.; Witheman, M.L.; Donovan Post, M.J.; Casillas, J.V.

    1995-01-01

    Morphological imaging, based on the use of various techniques including ultrasound, X-ray computed tomography (CT), and magnetic resonance imaging (MRI), plays an important role in the characterization, diagnosis and follow-up of patients with Human Immunodeficiency Virus (HIV) infection and Acquired Immunodeficiency Syndrome (AIDS). While the presence of thoracic infections, the most frequently observed illnesses in AIDS patients, can best be performed by using conventional chest films and CT, the assessment of cerebral involvement in AIDS patients - characterized by the presence of focal masses, demyelination, meningitis, and infarction - is best achieved using MRI. The work-up of patients with gastrointestinal symptoms should include the use of ultrasound for the evaluation of visceral involvement and lymphadenopathy, completed by CT to further characterize pathologic conditions in either the bowel or visceral organs. Ultrasound is the screening exam of choice in AIDS patients with suspected renal disease, but other methods may be necessary for the assessment of the complications due to pharmacological treatment. Musculoskeletal complications may require the combined use of all the above methods, since they may be caused by infections, tumors and rheumatologic illness. The use of the radiographic methods for the detection of the numerous forms of infections and malignancies in AIDS patients is described in detail for the various body districts

  7. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  8. Radiographic features of appendiceal colic in children

    International Nuclear Information System (INIS)

    Schisgall, R.M.

    1986-01-01

    The concept of appendiceal colic was introduced in 1980 to explain the common problem of recurrent crampy abdominal pain (RAP) in children. Children with appendiceal colic often have inspissated casts of stool as foreign bodies of the appendix. The radiographic findings of 115 children operated upon for appendiceal colic have been reviewed. The radiographic features of this syndrom have included: filling defects of the appendix (83% incidence of inspissated casts of stool within the appendix); partial filling of the appendix (44% incidence of fecal casts); retained barium behind 72 h (92% incidence of fecal casts blocking egress of barium); non-visualization of the appendix (42% incidence of fecal casts); and distention of the appendix (100% incidence of fecal casts). The correlation of radiographic and operative findings will be presented. A rational approach to the radiographic workup of a child with RAP will be presented. (orig.)

  9. Radiographers and radiologists reporting plain radiograph requests from accident and emergency and general practice

    International Nuclear Information System (INIS)

    Brealey, S.D.; King, D.G.; Hahn, S.; Crowe, M.; Williams, P.; Rutter, P.; Crane, S.

    2005-01-01

    AIM: To assess selectively trained radiographers and consultant radiologists reporting plain radiographs for the Accident and Emergency Department (A and E) and general practitioners (GPs) within a typical hospital setting. METHODS: Two radiographers, a group of eight consultant radiologists, and a reference standard radiologist independently reported under controlled conditions a retrospectively selected, random, stratified sample of 400 A and E and 400 GP plain radiographs. An independent consultant radiologist judged whether the radiographer and radiologist reports agreed with the reference standard report. Clinicians then assessed whether radiographer and radiologist incorrect reports affected confidence in their diagnosis and treatment plans, and patient outcome. RESULTS: For A and E and GP plain radiographs, respectively, there was a 1% (95% confidence interval (CI) -2 to 5) and 4% (95% CI -1 to 8) difference in reporting accuracy between the two professional groups. For both A and E and GP cases there was an 8% difference in the clinicians' confidence in their diagnosis based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 2% and 8% difference in the clinicians' confidence in their management plans based on radiographer or radiologist incorrect reports. For A and E and GP cases, respectively, there was a 1% and 11% difference in effect on patient outcome of radiographer or radiologist incorrect reports. CONCLUSION: There is the potential to extend the reporting role of selectively trained radiographers to include plain radiographs for all A and E and GP patients. Further research conducted during clinical practice at a number of sites is recommended

  10. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  11. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  12. Consultant radiographer leadership - A discussion

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter [Directorate of Radiography, University of Salford, Allerton Building, Frederick Road, Salford, Greater Manchester M6 6PU (United Kingdom)], E-mail: p.hogg@salford.ac.uk; Hogg, Dianne [Henwood Associates (South East) Ltd, Company Number: 513796, Registered Office: 2 Lakeview Stables, Lower St Clere, Kemsing, Kent, TN15 6NL (United Kingdom); Henwood, Suzanne [East Lancashire Primary Care Trust, Linden Business Centre, Linden Road, Colne. BB8 9BA (United Kingdom)

    2008-12-15

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills.

  13. Early characteristic radiographic changes in mucolipidosis II

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Lillian M. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); Lachman, Ralph S. [Lucile Packard Children' s Hospital and Stanford University, Pediatric Radiology, Palo Alto, CA (United States); University of California, International Skeletal Dysplasia Registry, Los Angeles, CA (United States)

    2016-11-15

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  14. Early characteristic radiographic changes in mucolipidosis II

    International Nuclear Information System (INIS)

    Lai, Lillian M.; Lachman, Ralph S.

    2016-01-01

    Although mucolipidosis type II has similar metabolic abnormalities to those found in all the mucopolysaccharidoses and mucolipidoses, there are distinctive diagnostic radiographic changes of mucolipidosis II in the perinatal/newborn/infant period. To describe the early characteristic radiographic changes of mucolipidosis II and to document when these changes manifest and resolve. We retrospectively reviewed radiographs and clinical records of 19 cases of mucolipidosis II from the International Skeletal Dysplasia Registry (1971-present; fetal age to 21/2 years). A radiologist with special expertise in skeletal dysplasias evaluated the radiographs. The most common abnormalities were increased vertebral body height (80%, nonspecific), talocalcaneal stippling (86%), periosteal cloaking (74%) and vertebral body rounding (50%). Unreported findings included sacrococcygeal sclerosis (54%) and vertebral body sclerosis (13%). Rickets and hyperparathyroidism-like (pseudohyperparathyroidism) changes (rarely reported) were found in 33% of cases. These changes invariably started in the newborn period and resolved by 1 year of age. The conversion from these early infantile radiographic features to dysostosis multiplex changes occurred in 41% of cases, and within the first year after birth. Several findings strongly suggest the diagnosis of mucolipidosis II, including cloaking in combination with one or more of the following radiographic criteria: talocalcaneal stippling, sacrococcygeal or generalized vertebral body sclerosis, vertebral body rounding, or rickets/hyperparathyroidism-like changes in the perinatal/newborn/infancy period. These findings are not found in the other two forms of mucolipidosis nor in any of the mucopolysaccharidoses. (orig.)

  15. Radiographic manifestations of arthritis in AIDS patients

    International Nuclear Information System (INIS)

    Rosenberg, Z.S.; Norman, A.; Solomon, G.

    1988-01-01

    The purpose of this study is to familiarize the radiologist with a newly discovered association between arthritis and acquired immunodeficiency syndrome (AIDS). The authors retrospectively reviewed the clinical and radiographic findings in 31 patients with human immunodeficiency virus (HIV) infection referred to their rheumatology clinic with musculoskeletal complaints. The patients carried a wide range of clinical diagnosis including Reiter syndrome, psoriatic arthritis, undifferentiated seronegative arthritis, isolated enthesopathies, rheumatoid arthritis and osteonecrosis. Radiographs were available in 24 of the 31 patients, and in 20 they showed radiographic features of arthritis, which included soft-tissue swelling periarticular osteoporosis, synovial effusions, sacroiliitis, periosteal reaction, joint space narrowing, marginal erosions, and osteonecrosis. Although the radiographic abnormalities were frequently mild, they were significant, given the short duration of disease in many of their patients (weeks to months) at the time radiographs were obtained. The range of radiographic findings in their series was varied and paralleled the wide range of clinical diagnoses. No findings were pathognomonic for HIV-associated arthritis. Nevertheless, HIV infection needs to be considered in any patient belonging to a recognized risk group who presents with musculoskeletal disease. This is particularly important since immunosupressive drugs used for the treatment of arthritis can be detrimental to patients with HIV infection

  16. Radiation protection education and training of radiographers

    International Nuclear Information System (INIS)

    Elsakkers, P.

    1995-01-01

    The International Society of Radiographers and Radiological Technicians (ISRRT) is an international non-governmental organisation in official relationship with the World Health Organization. Over 50 countries are members of the ISRRT. The ISRRT encourages and facilitates communication between radiographers throughout the world. The ISRRT has produced several documents, e.g. ''The Role of the Radiographer in Europe''. The ISRRT has also done research and developed initiatives to analyse the quality of training of radiographers in the different member states of the EC. Research was done in the member states to analyse the efforts in the field of quality control. An extended study was performed on the current level of education in radiation protection in the European member states. The ICRP recommends in its publications the need of good training and continuing education for all radiographers. An important part of the basic training of radiographers should focus on the performance of radiation protection and quality control tests. Good daily practice can decrease patient dose in many ways. (Author)

  17. Radiographic signs and diagnosis of dental disease

    International Nuclear Information System (INIS)

    Bellows, J.

    1993-01-01

    Dental radiographs are critical for the complete assessment and treatment of dental diseases. Dental radiography is commonly used to evaluate congenital dental defects, periodontal disease, orthodontic manipulations, oral tumors, endodontic treatments, oral trauma, and any situation where an abnormality is suspected. Although standard radiographic equipment and film can be used to produce dental radiographs, dental X-ray equipment and film provide superior quality images and greater convenience of animal patient positioning. An understanding of normal dental radiographic anatomy is important when interpreting dental radiographs. Stage III periodontitis is the earliest stage of periodontal disease at which radiographic abnormalities become apparent. Bone loss associated with periodontal disease can be classified as either horizontal or vertical. Periapical radiolucencies can represent granulomas, cysts, or abscesses, whereas periapical radiodensities may represent sclerotic bone or condensing osteitis. Lytic lesions of the bone of the jaw often represent oral neoplasms. Neoplasms also can displace or disrupt teeth in the dental arch. Resorptive lesions can be external or internal and appear as radiolucent areas involving the external surface of the root or the pulp cavity, respectively. Feline dental resorptive lesions, also known as odontoclastic resorptions, are a specific form of dental resorptive lesions unique to cats

  18. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  19. Radiographer performed single contrast small bowel enteroclysis

    International Nuclear Information System (INIS)

    Law, Robert L.; Slack, Nicola; Harvey, Richard F.

    2005-01-01

    Aim: To analyse the technical success and reporting sensitivity of radiographer performed small bowel enteroclysis (SBE) undertaken by a specialist radiographer according to a standard technique [Nolan DJ, Cadman PJ. The small bowel enema made easy. Clinical Radiology 1987;38(3):295-301]. Methods: Patients (1413) had 1646 SBE in 10 years from May 1992 to April 2002. The original request card and the separate radiographer and consultant radiologist reports were reviewed. Where the radiology reports were discordant or inconclusive, the clinical notes were also reviewed. Results: Patients (1022) X-ray films were available. Nine hundred and forty-three (93.3%) SBEs had been successfully completed. Radiographer and consultant radiologist reporting had a 99.3% concordance. There was a 98.4% sensitivity for Crohn's disease (181 of 184 cases where Crohn's disease was the clinical final diagnosis). Overall reporting sensitivity was 93.7% although correct 'probably normal and abnormal' reporting bias suggests a sensitivity of 96.9%. Sixty of 943 (6.4%) reports were inconclusive. Of 1022 patients, 68 (6.6%) of small bowel intubations were not achieved, or else consent was withdrawn at the time of the procedure. Conclusion: Specialist radiographers can perform small bowel enteroclysis with a reporting sensitivity equal to that of a consultant radiologist. Radiographers accustomed to providing an SBE service become skilled at passing fine bore feeding tubes into the small bowel and can provide this service also

  20. Radiographic and Clinical Analysis of Lateral Epicondylitis.

    Science.gov (United States)

    Shillito, Matthew; Soong, Maximillian; Martin, Nicholas

    2017-06-01

    The literature suggests that radiographs may be unnecessary in the initial evaluation of lateral epicondylitis because treatment is rarely altered as a result of the radiographic findings. The most commonly reported radiographic finding is calcification at the lateral epicondyle. Our goal was to perform a quantitative and qualitative analysis of this finding to determine its importance and possible relationship with various clinical factors and patient-reported measures. All patients diagnosed with lateral epicondylitis by a single surgeon during a 5-year period were retrospectively reviewed. Age, sex, laterality, hand dominance, pain visual analog scale, duration of symptoms, Quick-Disability of the Arm, Shoulder, and Hand questionnaire score, and history of steroid injection were recorded. Calcifications on standard elbow radiographs, acquired digitally and viewed at 200% magnification on a 24-inch monitor, were characterized by size and relationship with the lateral epicondyle. We reviewed 245 patients diagnosed with lateral epicondylitis. A total of 115 elbows (47%) demonstrated lateral epicondyle calcifications. Patients with and without calcifications were similar with regard to clinical factors, as were patients with larger or smaller lesions. Eighty-five elbows (35%) had additional radiographic findings. Treatment was not altered by the radiographic findings in any case. Lateral epicondyle calcifications are much more common in lateral epicondylitis than previously reported, possibly owing to modern digital radiography and magnification, although they do not appear to be related to clinical factors including patient-reported measures. Thus, patients and surgeons should be careful to avoid overinterpretation of such findings. Although radiographs may be helpful in ruling out additional pathology, we did not find other clinically important contributions to the initial evaluation and management of this condition, and thus we do not recommend their routine use

  1. Chest radiograph interpretation by medical students

    International Nuclear Information System (INIS)

    Jeffrey, D.R.; Goddard, P.R.; Callaway, M.P.; Greenwood, R.

    2003-01-01

    AIM: To assess the ability of final year medical students to interpret conventional chest radiographs. MATERIALS AND METHODS: Ten conventional chest radiographs were selected from a teaching hospital radiology department library that were good radiological examples of common conditions. All were conditions that a medical student should be expected to recognize by the end of their training. One normal radiograph was included. The radiographs were shown to 52 final year medical students who were asked to describe their findings. RESULTS: The median score achieved was 12.5 out of 20 (range 6-18). There was no difference between the median scores of male and female students (12.5 and 12.3, respectively, p=0.82) but male students were more likely to be certain of their answers than female students (median certainty scores 23.0 and 14.0, respectively). The overall degree of certainty was low. On no radiograph were more than 25% of students definite about their answer. Students had received little formal radiology teaching (2-42 h, median 21) and few expressed an interest in radiology as a career. Only two (3.8%) students thought they were good at interpreting chest radiographs, 17 (32.7%) thought they were bad or awful. CONCLUSION: Medical students reaching the end of their training do not perform well at interpreting simple chest radiographs. They lack confidence and have received little formal radiological tuition. Perhaps as a result, few are interested in radiology as a career, which is a matter for concern in view of the current shortage of radiologists in the UK

  2. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  3. Radiographic testing - optimum radiographs of plastics and composite materials with dosimeter control

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wavelength radiation corresponding 10 to 25 kV.P. (orig.) [de

  4. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  5. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  6. Radiographers' preconditions for evidence-based radiography

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari; Liikanen, Eeva

    2010-01-01

    Evidence-based practice (EBP) is essential in today's health care, but its establishment requires several preconditions from individuals and organizations (e.g. knowledge, understanding, attitudes, abilities, self-confidence, support, and resources). Previous studies suggest that radiographers do generate and use evidence in their work, but evidence-based radiography (EBR) is not yet used routinely as established practice, especially in terms of research utilization. This paper aims to describe radiographers' preconditions for EBR, and their participation in research activities. Main focus is on research utilization. Using an electronic questionnaire developed for this study, a survey was conducted: data collected from Finnish radiographers and radiotherapists (N = 438) were analysed both statistically and qualitatively. The final response rate was 39%. The results suggest radiographers' preconditions for EBR to consist of knowledge of research, significance of research activities, research-orientated way of working, and support. In addition, adequate resourcing is essential. Reading scientific journals, participation in research activities, a higher degree of education, and senior post seem to be significant promoters of EBR and research utilization. The results support the notion that EBR, and especially research utilization, are not yet well-established in Finland, and radiographers' viewpoints concerning the role and significance of research evidence and research activities still seem to vary.

  7. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  8. Radiographic findings in tuberculosis of the calvarium

    Energy Technology Data Exchange (ETDEWEB)

    Patankar, T.; Varma, R.; Krishnan, A.; Prasad, S. [Dept. of Radiology, King Edward Memorial Hospital, Parel, Bombay (India); Desai, K. [Dept. of Neurosurgery, King Edward Memorial Hospital, Bombay (India); Castillo, M. [Dept. of Radiology, University of North Carolina School of Medicine, Chapel Hill, NC (United States)

    2000-07-01

    We reviewed the pattern of involvement of the calvarium by tuberculosis (TB) in five patients and the role of imaging in its management. Four patients presented with localised scalp swelling and one with generalized seizures. Radiographs revealed lucent lesions with minimal surrounding sclerosis in the frontal (2), parietal (2) and occipital (1) bones. CT showed lesions involving the entire thickness of the calvarium and accompanying contrast-enhancing soft tissue. The patient presenting with seizures had a ring-enhancing lesion in the parietal lobe in addition to the extra-axial lesions. Although radiographs in all cases demonstrated calvarial TB, CT showed the extent of the defect, involvement of adjacent soft tissues, and in one case an intra-axial lesion. Radiographs suffice for follow-up of these patients. (orig.)

  9. Understanding chest radiographic anatomy with MDCT reformations

    Energy Technology Data Exchange (ETDEWEB)

    Sussmann, A.R. [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States); Ko, J.P., E-mail: jane.ko@nyumc.or [Department of Radiology, Thoracic Imaging, NYU Langone Medical Center, New York, NY (United States)

    2010-02-15

    Chest radiograph interpretation requires an understanding of the mediastinal reflections and anatomical structures. Computed tomography (CT) improves the learning of three-dimensional (3D) anatomy, and more recently multidetector CT (MDCT) technology has enabled the creation of high-quality reformations in varying projections. Multiplanar reformations (MPRs) of varying thickness in the coronal and sagittal projections can be created for direct correlation with findings on frontal and lateral chest radiographs, respectively. MPRs enable simultaneous visualization of the craniocaudal extent of thoracic structures while providing the anatomic detail that has been previously illustrated using cadaveric specimens. Emphasis will be placed on improving knowledge of mediastinal anatomy and reflections including edges, lines, and stripes that are visible on chest radiographs.

  10. Radiographic abnormalities in tricyclic acid overdose

    International Nuclear Information System (INIS)

    Varnell, R.M.; Richardson, M.L.; Vincent, J.M.; Godwin, J.D.

    1987-01-01

    Several case reports have described adult respiratory distress syndrome (ARDS) secondary to tricyclic acid (TCA) overdose. During a 1-year period 83 patients requiring intubation secondary to drug overdose were evaluated. Abnormalities on chest radiographs occurred in 26 (50%) of the 54 patients with TCA overdose, compared to six (21%) of the 29 patients overdosed with other drugs. In addition, five (9%) of the patients with TCA overdose subsequently had radiographic and clinical abnormalities meeting the criteria for ARDS. Only one (3%) of the patients with non-TCA overdose subsequently had change suggesting ARDS. TCAs should be added to the list of drugs associated with ARDS, and TCA overdose should be considered a major risk factor in the development of radiographically evident abnormalities

  11. Opportunistic esophagitis in AIDS: Radiographic diagnosis

    International Nuclear Information System (INIS)

    Levine, M.S.; Woldenberg, R.; Herlinger, H.; Laufer, I.

    1987-01-01

    Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention

  12. Development of low-silver radiographic detectors

    International Nuclear Information System (INIS)

    Troitskij, V.A.; Novikov, I.A.; Nikitin, V.F.; Krasnyj-Admoni, L.V.; Valevich, M.I.; Belyj, N.G.; Grom, V.S.

    1988-01-01

    The results of investigations on radiographic testing of welded joints of St20, 08Kh18N10T steels, the AMG-6 alloy, copper, titanium using radiographic detectors with the low silver content are presented. The roentgenographic and photographic paper, as well as the samples of experimental films with heavy elements in the photolayer are tested using intensifying screens of different types. Experimental films containing silver 2 times as less as standard X-ray films are shown to provide the similar sensitivity of testing under equal conditions, but the exposure time is two times higher. Prints on the radiophotographic paper in quality and exposure time approach to prints obtained on the RT-1 film containing silver 10 times less than that in the roentgenographic film. The exposure time of the radiographic paper is several times less than that of the ''unibrom'' contrast paper. The testing sensitivity decreases to some extent in this case

  13. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  14. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  15. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  16. Pseudoprominent aorta: Radiographic findings and CT correlation

    International Nuclear Information System (INIS)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-01-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented

  17. Inferior hilar window on lateral chest radiographs

    International Nuclear Information System (INIS)

    Park, C.K.; Webb, W.R.; Klein, J.S.

    1990-01-01

    This paper determines the accuracy of lateral chest radiography in the detection of masses in the inferior hilar window, a normally avascular hilar region anterior to the lower lobe bronchi. Fifty patients with normal thoracic CT scans and 25 with hilar masses/adenopathy were selected retrospectively. The 75 corresponding lateral chest radiographs were blindly evaluated for visibility of the anterior walls of the lower lobe bronchi and the presence and laterality of abnormal soft tissue (>1 cm) in the inferior hilar window. Only a 7 x 7-cm square of the lateral radiograph was viewed

  18. Pelvic radiograph in skeletal dysplasias: An approach

    Directory of Open Access Journals (Sweden)

    Manisha Jana

    2017-01-01

    Full Text Available The bony pelvis is constituted by the ilium, ischium, pubis, and sacrum. The pelvic radiograph is an important component of the skeletal survey performed in suspected skeletal dysplasia. Most of the common skeletal dysplasias have either minor or major radiological abnormalities; hence, knowledge of the normal radiological appearance of bony pelvis is vital for recognizing the early signs of various skeletal dysplasias. This article discusses many common and some uncommon radiological findings on pelvic radiographs along with the specific dysplasia in which they are seen; common differential diagnostic considerations are also discussed.

  19. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  20. Cardiac and pericardial calcifications on chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, E.C., E-mail: ecferguson@hotmail.co [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States); Berkowitz, E.A. [University of Texas Medical School at Houston, Department of Diagnostic and Interventional Imaging, Section of Thoracic Imaging, Houston, TX 77030 (United States)

    2010-09-15

    Many types of cardiac and pericardial calcifications identified on chest radiographs can be recognized and distinguished based on characteristic locations and appearances. The purpose of this review is to emphasize the importance of detecting cardiac and pericardial calcifications on chest radiographs, and to illustrate and describe the various types of calcifications that may be encountered and how they may be differentiated from one another. Each type of cardiac and pericardial calcification is discussed, its location and appearance described, and its significance explained. Recognizing and understanding these calcifications is important as they are often encountered in daily practice and play an important role in patient care.

  1. Pattern of scattered exposure from portable radiographs

    International Nuclear Information System (INIS)

    North, D.

    1985-01-01

    Concern periodically arises among the nursing and medical staffs of the institution's intensive care unit regarding their occupational exposure to radiation from the many radiographs taken in the unit. The patients are located in open areas or within individual cubicles whose walls are relatively thin and not shielded. To form a data base for educating the nursing/medical staffs and the technologists, the intensity and distribution of scattered exposure from actual radiographs of patients were measured. Comparison was also made with a simple phantom experiment in which the variables could be more precisely controlled

  2. Diagnosis of calcification on abdominal radiographs

    International Nuclear Information System (INIS)

    Lamb, C.R.; Kleine, L.J.; McMillan, M.C.

    1991-01-01

    A wide variety of normal and pathologic factors may induce intraabdominal calcification. In general, the most reliable indication of the cause of a calcification is its location; therefore, if the affected organ can be identified the radiographic diagnosis is often straightforward or, at least, limited to relatively few possibilities. With this principle in mind, a series of patients with abdominal calcification are described for the purpose of illustrating the appearance of calcification of various abdominal organs. In addition, etiology for the calcification in each patient is discussed. Certain extraabdominal calcifications which may be seen on abdominal radiographs are also mentioned

  3. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  4. Evaluation of contrast in duplicated radiographs

    International Nuclear Information System (INIS)

    Thunthy, K.H.; Weinberg, R.

    1982-01-01

    This investigation evaluated changes in the contrast of duplicated radiographs made at different ultraviolet light exposures. Increasing ultraviolet light exposure had different effects on the duplicates of originals of different background densities. When correctly exposed, a duplicate radiograph enhanced contrast. When originals had the same contrast but different background densities, their duplicates did not have the same contrast. It was not possible to duplicate accurately all the different contrasts measured on an original. It was possible, however, to produce duplicates with all contrasts greater than those of the original

  5. A radiographic study of the position and shape of mental foramen in panoramic radiographs

    International Nuclear Information System (INIS)

    Choi, Karp Shik; Kim, Dong Youn; Sohn, Jeong Ick; Bae, Yong Chul

    1997-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in panoramic radiographs. For this study, panoramic radiographs were obtained from the 200 adults and evaluated the position and shape of mental foramen. According to various positional changes in panoramic radiographs of the patients, the author also obtained panoramic radiographs from the 100 adults and then evaluated the positional and shape changes of mental foramen. The following results were obtained : 1. Shapes of mental foramen were observed elliptical (43.3%), round or oval (42.5%), unidentified (7.5%) and diffuse (6.7%) type in descending order of frequency. 2. Horizontal position of mental foramen were most frequently observed at the 2nd premolar area (54.2%), and area between the 1st premolar and 2nd premolar (43.1%), area between the 2nd premolar and 1st molar (2.7%), and at apex (9.7%), overlap with apex (1.9%), superior of apex (0.2%) in descending order of frequency. 4. According to various positional changes in panoramic radiographs of the patients, shape changes of mental foramen were more obviously observed at the forward 10 mm and chin down 10 degree positioned panoramic radiographs, And changes of horizontal and vertical position were observed in similar to compared with normal positioned panoramic radiographs.

  6. The radiographer's role in child protection: Comparison of radiographers perceptions by use of focus groups

    International Nuclear Information System (INIS)

    Davis, Michaela; Reeves, Pauline

    2006-01-01

    The research presented in this paper is taken from a larger study whose aims were to devise a holistic picture of how diagnostic radiographers approach child protection issues and to explore how radiographers and other professionals see the role of radiographers in the chain of evidence in relation to child protection as this applies to children who present at the Imaging Department with suspected non-accidental injuries (NAI). A focus group methodology was used with focus groups being conducted in the United Kingdom and Republic of Ireland. The results indicated that both United Kingdom and Republic of Ireland radiographers agreed that they had a role in child protection; however, they identified a wide interpretation as to the extent of that role. Although radiographers in the United Kingdom and Republic of Ireland work within different legal systems there were themes identified which were common to both countries. Although radiographers referred to a duty to the child as to all patients, no radiographer specifically mentioned the system and child care law under which it is assumed they operate. This research revealed an area which would benefit from more detailed research using a wider audience. However, the study revealed a need for training in relation to possible NAI indicators and the correct procedure for documenting their suspicions and initiating an NAI referral

  7. Three-dimensional hindfoot alignment measurements based on biplanar radiographs: comparison with standard radiographic measurements

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Buck, Florian M.; Espinosa, Norman

    2013-01-01

    To establish a hindfoot alignment measurement technique based on low-dose biplanar radiographs and compare with hindfoot alignment measurements on long axial view radiographs, which is the current reference standard. Long axial view radiographs and low-dose biplanar radiographs of a phantom consisting of a human foot skeleton embedded in acrylic glass (phantom A) and a plastic model of a human foot in three different hindfoot positions (phantoms B1-B3) were imaged in different foot positions (20 internal to 20 external rotation). Two independent readers measured hindfoot alignment on long axial view radiographs and performed 3D hindfoot alignment measurements based on biplanar radiographs on two different occasions. Time for three-dimensional (3D) measurements was determined. Intraclass correlation coefficients (ICC) were calculated. Hindfoot alignment measurements on long axial view radiographs were characterized by a large positional variation, with a range of 14 /13 valgus to 22 /27 varus (reader 1/2 for phantom A), whereas the range of 3D hindfoot alignment measurements was 7.3 /6.0 to 9.0 /10.5 varus (reader 1/2 for phantom A), with a mean and standard deviation of 8.1 ± 0.6/8.7 ± 1.4 respectively. Interobserver agreement was high (ICC = 0.926 for phantom A, and ICC = 0.886 for phantoms B1-B3), and agreement between different readouts was high (ICC = 0.895-0.995 for reader 1, and ICC = 0.987-0.994 for reader 2) for 3D measurements. Mean duration of 3D measurements was 84 ± 15/113 ± 15 s for reader 1/2. Three-dimensional hindfoot alignment measurements based on biplanar radiographs were independent of foot positioning during image acquisition and reader independent. In this phantom study, the 3D measurements were substantially more precise than the standard radiographic measurements. (orig.)

  8. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  9. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  10. Ergonomic strategies to improve radiographers' posture during mammography activities.

    Science.gov (United States)

    Cernean, Nicolai; Serranheira, Florentino; Gonçalves, Pedro; Sá Dos Reis, Cláudia

    2017-08-01

    To identify alternatives for radiographers' postures while performing mammography that can contribute to reduce the risk of work-related musculoskeletal disorders (WRMSDs). Radiographers' postures to positioning craniocaudal (CC) and mediolateral oblique (MLO) views were simulated without any intervention for three scenarios: radiographer/patient with similar statures, radiographer smaller than patient and radiographer taller than patient. Actions were taken to modify the postures: seated radiographer; patient on a step; seated patient; radiographer on a step. All the postures were analysed using kinovea 0.8.15 software and the angles were measured twice and classified according to European standard EN1005-4: 2005. The non-acceptable angles were measured mainly during MLO positioning when radiographer was taller than the patient: 139° and 120° for arm-flexion and abduction, 72° for trunk and -24° for head/neck-flexion. The introduction of alternative postures (radiographer seated), allowed improvements in posture (60° and 99° for arm flexion and abduction, 14° for trunk and 0° for head/neck flexion), being classified as acceptable. The alternative postures simulated have the potential to reduce the risk of developing WRMSDs when radiographers and patients have different statures. • Radiographers' postures in mammography can contribute to work-related musculoskeletal disorders • Non-acceptable posture was identified for MLO breast positioning (radiographer taller than patient) • Adapting posture to patient biotype reduces the WRMSD risk for radiographers.

  11. Algorithms for boundary detection in radiographic images

    International Nuclear Information System (INIS)

    Gonzaga, Adilson; Franca, Celso Aparecido de

    1996-01-01

    Edge detecting techniques applied to radiographic digital images are discussed. Some algorithms have been implemented and the results are displayed to enhance boundary or hide details. An algorithm applied in a pre processed image with contrast enhanced is proposed and the results are discussed

  12. Comparison of radiographic technique by computer simulation

    International Nuclear Information System (INIS)

    Brochi, M.A.C.; Ghilardi Neto, T.

    1989-01-01

    A computational algorithm to compare radiographic techniques (KVp, mAs and filters) is developed based in the fixation of parameters that defines the images, such as optical density and constrast. Before the experience, the results were used in a radiography of thorax. (author) [pt

  13. Detecting objects in radiographs for homeland security

    Science.gov (United States)

    Prasad, Lakshman; Snyder, Hans

    2005-05-01

    We present a general scheme for segmenting a radiographic image into polygons that correspond to visual features. This decomposition provides a vectorized representation that is a high-level description of the image. The polygons correspond to objects or object parts present in the image. This characterization of radiographs allows the direct application of several shape recognition algorithms to identify objects. In this paper we describe the use of constrained Delaunay triangulations as a uniform foundational tool to achieve multiple visual tasks, namely image segmentation, shape decomposition, and parts-based shape matching. Shape decomposition yields parts that serve as tokens representing local shape characteristics. Parts-based shape matching enables the recognition of objects in the presence of occlusions, which commonly occur in radiographs. The polygonal representation of image features affords the efficient design and application of sophisticated geometric filtering methods to detect large-scale structural properties of objects in images. Finally, the representation of radiographs via polygons results in significant reduction of image file sizes and permits the scalable graphical representation of images, along with annotations of detected objects, in the SVG (scalable vector graphics) format that is proposed by the world wide web consortium (W3C). This is a textual representation that can be compressed and encrypted for efficient and secure transmission of information over wireless channels and on the Internet. In particular, our methods described here provide an algorithmic framework for developing image analysis tools for screening cargo at ports of entry for homeland security.

  14. 21 CFR 1020.31 - Radiographic equipment.

    Science.gov (United States)

    2010-04-01

    ...) RADIOLOGICAL HEALTH PERFORMANCE STANDARDS FOR IONIZING RADIATION EMITTING PRODUCTS § 1020.31 Radiographic... and time, a preset number of pulses, or a preset radiation exposure to the image receptor. (i) Except... exposure of greater than one-half second. Except during panoramic dental radiography, termination of...

  15. Radiographic contrast media, function and future reassessed

    International Nuclear Information System (INIS)

    Sovak, M.

    1988-01-01

    A brief review is given of the use of radiographic contrast media in cholecysto- and cholangiography, central nervous system imaging, urography and angiography. Other aspects briefly discussed are the use of large i.v. doses of contrast media for CT contrast enhancement and the design theory for improved water soluble contrast media. (U.K.)

  16. Radiographic analysis of ameloblastoma: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chandramani More

    2012-01-01

    Conclusion: Radiographs are an important aid for the diagnosis of oral lesions of various types, especially those that involve bone. It is important for the practicing clinicians to know the salient features of ameloblastoma which are peculiar to the local population.

  17. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  18. Unusual radiographic changes of a gout patient

    International Nuclear Information System (INIS)

    Markota, J.

    2004-01-01

    Background. Gout is a metabolic disorder that results in hyperuricemia and accumulation of uric acid crystals (urats) in tissues, especially joint cartilage. The gouty arthritis presents as acute attacks of arthritis leading eventually to chronic gouty arthritis. In 80% of cases it first occurs in the matatarsophalangeal (MTP) joint of the great toe and is more frequent in male population. Case report. We present a case of unusual radiographic changes accompanying gouty arthritis. A 63 year old female complained about swelling of the first MTP joint on the right, right knee, about stiffness of feet and hands' digits and about backache. First symptoms started to appear 30 years ago. In the time of examination radiographs displayed degenerative changes of the majority of presented joints, bilateral sacroiliitis and osseous ankylosis of both insteps. Microscopic examination showed urate crystals in the samples of the synovial fluid aspirated from the knee. The histological findings of the synovial tissue after the synovectomy were also in favour of gouty arthritis. Conclusions. Radiographs are the most important imaging modality in the diagnostic process of gout. However, radiographic differential diagnosis can be difficult, since the findings overlap with other conditions which cause arthritis and osteoarthritis especially in longstanding gout, elderly patients and females. The diagnosis must be often confirmed with the help of laboratory and histological findings. (author)

  19. Transfer function analysis of radiographic imaging systems

    International Nuclear Information System (INIS)

    Metz, C.E.; Doi, K.

    1979-01-01

    The theoretical and experimental aspects of the techniques of transfer function analysis used in radiographic imaging systems are reviewed. The mathematical principles of transfer function analysis are developed for linear, shift-invariant imaging systems, for the relation between object and image and for the image due to a sinusoidal plane wave object. The other basic mathematical principle discussed is 'Fourier analysis' and its application to an input function. Other aspects of transfer function analysis included are alternative expressions for the 'optical transfer function' of imaging systems and expressions are derived for both serial and parallel transfer image sub-systems. The applications of transfer function analysis to radiographic imaging systems are discussed in relation to the linearisation of the radiographic imaging system, the object, the geometrical unsharpness, the screen-film system unsharpness, other unsharpness effects and finally noise analysis. It is concluded that extensive theoretical, computer simulation and experimental studies have demonstrated that the techniques of transfer function analysis provide an accurate and reliable means for predicting and understanding the effects of various radiographic imaging system components in most practical diagnostic medical imaging situations. (U.K.)

  20. Radiographic Features of Acute Patellar Tendon Rupture.

    Science.gov (United States)

    Fazal, Muhammad Ali; Moonot, Pradeep; Haddad, Fares

    2015-11-01

    The purpose of our study was to assess soft tissue features of acute patellar tendon rupture on lateral knee radiograph that would facilitate early diagnosis. The participants were divided into two groups of 35 patients each. There were 28 men and seven women with a mean age of 46 years in the control group and 26 men and nine women with a mean age of 47 years in the rupture group. The lateral knee radiograph of each patient was evaluated for Insall-Salvati ratio for patella alta, increased density of the infrapatellar fat pad, appearance of the soft tissue margin of the patellar tendon and bony avulsions. In the rupture group there were three consistent soft tissue radiographic features in addition to patellar alta. These were increased density of infrapatellar fat pad; loss of sharp, well-defined linear margins of the patellar tendon and angulated wavy margin of the patellar tendon while in the control group these features were not observed. The soft tissue radiographic features described in the rupture group are consistent and reliable. When coupled with careful clinical assessment, these will aid in early diagnosis and further imaging will be seldom required. © 2015 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  1. Assessment of radiation protection practices among radiographers ...

    African Journals Online (AJOL)

    Application of shielding devices such as gonad shield for protection was neglected mostly in government hospitals. Most x-ray machines were quite old and evidence of quality assurance tests performed on such machines were lacking. Conclusion: Radiographers within Lagos metropolis showed an excellent knowledge of ...

  2. Chest radiographic findings in Human Immunodeficiency Virus ...

    African Journals Online (AJOL)

    This study was carried out to determine findings on chest radiographs in HIV positive/AIDS patients at the University of Benin Teaching Hospital (UBTH) Benin City. All consecutive HIV positive/AIDS patients, managed at the UBTH between 1991 and 2001 were included in the study. Patients had postero-anterior (PA) chest ...

  3. Thoracic radiographic anatomy in goats | Makungu | Tanzania ...

    African Journals Online (AJOL)

    The aim of this study was to describe the normal radiographic anatomy of the thorax of small East African goats as a reference for clinical use. Radiography of the thorax was performed under general anaesthesia in 10 healthy small East African goats. Right lateral (RL), left lateral (LL), dorsoventral (DV) and ventrodorsal ...

  4. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  5. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  6. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  7. Correlation Of Radiographic Patterns Of Pulmonary Tuberculosis ...

    African Journals Online (AJOL)

    Patients with higher CD4+ counts often present in \\"classic\\" fashion (upper zone infiltrates cavities) whereas those with low CD4+ counts are more likely to present atypically. The chest radiographic appearances of HIV-seropositive patients presenting with pulmonary tuberculosis (PTB) are diverse, creating difficulty in ...

  8. Effects of rotation radiographic dimensions of metacarpals

    International Nuclear Information System (INIS)

    Armes, F.M.; Horsman, A.; Bentley, H.B.

    1979-01-01

    An experiment is described which shows that small rotations of metacarpals about their long axis produce small systematic changes in the cortical dimensions as measured by radiographic morphometry. The effect is of no significance in cross-sectional studies but is an important source of error in sequential studies. (author)

  9. Image rejects/retakes--radiographic challenges.

    Science.gov (United States)

    Waaler, D; Hofmann, B

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5 %. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter-subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted.

  10. Image rejects/retakes-radiographic challenges

    International Nuclear Information System (INIS)

    Waaler, D.; Hofmann, B.

    2010-01-01

    A general held position among radiological personnel prior to digitalisation was that the problem of image rejects/retakes should more or less vanish. However, rejects/retakes still impose several challenges within radiographic imaging; they occupy unnecessary resources, expose patients to unnecessary ionizing radiation and may also indicate suboptimal quality management. The latter is the main objective of this paper, which is based on a survey of international papers published both for screen/film and digital technology. The digital revolution in imaging seems to have reduced the percentage of image rejects/retakes from 10-15 to 3-5%. The major contribution to the decrease appears to be the dramatic reduction of incorrect exposures. At the same time, rejects/retakes due to lack of operator competence (positioning, etc.) are almost unchanged, or perhaps slightly increased (due to lack of proper technical competence, incorrect organ coding, etc.). However, the causes of rejects/retakes are in many cases defined and reported with reference to radiographers' subjective evaluations. Thus, unless radiographers share common views on image quality and acceptance criteria, objective measurements and assessments of reject/retake rates are challenging tasks. Interestingly, none of the investigated papers employs image quality parameters such as 'too much noise' as categories for rejects/retakes. Surprisingly, no reject/retake analysis seems yet to have been conducted for direct digital radiography departments. An increased percentage of rejects/retakes is related to 'digital skills' of radiographers and therefore points to areas for extended education and training. Furthermore, there is a need to investigate the inter subjectivity of radiographers' perception of, and attitude towards, both technical and clinical image quality criteria. Finally, there may be a need to validate whether reject/retake rate analysis is such an effective quality indicator as has been asserted

  11. Predicting lower third molar eruption on panoramic radiographs after cephalometric comparison of profile and panoramic radiographs

    DEFF Research Database (Denmark)

    Begtrup, Anders; Grønastøð, Halldis Á; Christensen, Ib Jarle

    2012-01-01

    and to find a simple and reliable method for predicting the eruption of the mandibular third molar by measurements on panoramic radiographs. The material consisted of profile and panoramic radiographs, taken before orthodontic treatment, of 30 males and 23 females (median age 22, range 18-48 years......Previous studies have suggested methods for predicting third molar tooth eruption radiographically. Still, this prediction is associated with uncertainty. The aim of the present study was to elucidate the association between cephalometric measurements on profile and panoramic radiographs...... the length from the ramus to the incisors (olr-id) showed a statistically significant correlation. By combining this length with the mesiodistal width of the lower second molar, the prediction of eruption of the lower third molar was strengthened. A new formula for calculating the probability of eruption...

  12. Occupational kneeling and radiographic tibiofemoral and patellofemoral osteoarthritis

    DEFF Research Database (Denmark)

    Rytter, Søren; Egund, Niels; Jensen, Lilli Kirkeskov

    2009-01-01

    ABSTRACT: BACKGROUND: The objective of our study was to evaluate the association between occupational kneeling and compartment specific radiographic tibiofemoral (TF) and patellofemoral (PF) osteoarthritis (OA). METHODS: Questionnaire data and bilateral knee radiographs were obtained in 134 male...

  13. Recognizing the radiographic features of some common bovine foot problems

    International Nuclear Information System (INIS)

    Ebeid, M.; Steiner, A.

    1996-01-01

    Radiographs of an injured or infected bovine foot can be tricky to interpret - the anatomy is complex, and the signs may be subtle. This guide leads you through the classic radiographic features of several common foot conditions

  14. 21 CFR 892.1970 - Radiographic ECG/respirator synchronizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic ECG/respirator synchronizer. 892.1970... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1970 Radiographic ECG/respirator synchronizer. (a) Identification. A radiographic ECG/respirator synchronizer is a device intended to be used to...

  15. Appearance of the mandibular incisive canal on panoramic radiographs

    NARCIS (Netherlands)

    Jacobs, R.; Mraiwa, N.; van Steenberghe, D.; Sanderink, G.C.H.; Quirynen, M.

    2004-01-01

    Panoramic radiographs are routinely used in the dental office for various diagnostic purposes. This study aimed to evaluate the visibility of neurovascular structures in the mandibular interforaminal region on such radiographs. Panoramic radiographs were obtained with a Cranex Tome (Soredex) from

  16. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Digital radiographic assessment of coronary flow reserve

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1985-01-01

    A method for measuring relative changes in regional blood flow using digital radiographic enhancement of selective coronary arteriography. Coronary flow reserve is measured in individual arterial distributions using the washin ratio of contrast appearance time under baseline and hyperemic conditions. Information is quantitatively presented in functional (parametric) image format. These images, termed contrast medium appearance pictures (CMAP), depict the transit of contrast through the arterial, myocardial and early venous stages. This process can be divided into three general phases: data acquisition, CMAP formation and CMAP analysis. The technique has evolved over its development period from a cine film-based technology which required substantial processing time to a real-time digital radiographic technique

  18. RADIOGRAPHIC EXAMINATION OF TEMPOROMANDIBULAR DISORDERS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Heru Suryonegoro

    2015-06-01

    Full Text Available The temporomandibular joint has a very important role in the stomatognathic system. Its main function is for the opening and closing movement, mastication, and speech. It is located anterior to the ear. The temporomandibular joint connects maxilla and mandible through the articular fossa, hence the slightest change that happens would cause serious matters such as pain, exiting, speech disorder, difficulty in opening and closing movement, headache, and even trismus. In a child or an adolescent, the symptoms are often vague; everything is interpreted as “pain”. This is probably why temporomandibular disorder are often undetected by dentists. Therefore, patience and accuracy is needed to determine the actual disorder through means of clinical and radiographic examination. The radiographic examination suitable for child is the transcranial projection. This projection is believed to be more accurate amongst other projection for child patients.

  19. Radiographic examination of the equine stifle

    International Nuclear Information System (INIS)

    Denoix, J.M.

    1986-01-01

    A radiographic technique is described for the equine stifle joint with the horse in the standing position or under general anaesthesia. The method with the animal anaesthetised in the dorsal recumbency and the leg extended was preferred because it gave greater flexibility with a better range of views and greatly reduced the safety hazards. In the standing position a useful practical tip for the lateral view was to raise and extent the limb caudally. This provides some flexion and ventral movement of the stifle allowing improved access for the cassette, a more accurate lateral view of the joint and a reduction in exposure. Some of the features of radiographic anatomy, from birth to adulthood, of this rather complex joint are described to form a basis for radiological interpretation in cases of suspected stifle lameness

  20. The radiographic features of familial expansile osteolysis

    International Nuclear Information System (INIS)

    Crone, M.D.; Wallace, R.G.H.

    1990-01-01

    The radiographic features of a unique autosomal dominant bone dysplasia are presented. The features are classified as generalised and/or focal. Generalised features are either altered trabecular pattern or modelling abnormalities. Focal features comprise lytic areas which progressively enlarge, producing expansion of the bone and eventual disintegration due to fibrous and finally fatty replacement of the normal medulla. Almost 90% of these lesions occur in the appendicular skeleton. Clinically, hearing loss is the earliest manifestation of the disease, presenting sometimes as early as 4 years of age. Apical and cervical resorption of teeth is extremely common, resulting in premature loss of teeth. Radiologically, the differential diagnosis refers to Paget's disease, polyostotic fibrous dysplasia, and osteofibrous dysplasia. The progressive destruction of the bone is similar to massive osteolysis (Gorham's disease). The radiographic features in combination with the histopathology render the condition unique. (orig.)

  1. An Applied Image Processing for Radiographic Testing

    International Nuclear Information System (INIS)

    Ratchason, Surasak; Tuammee, Sopida; Srisroal Anusara

    2005-10-01

    An applied image processing for radiographic testing (RT) is desirable because it decreases time-consuming, decreases the cost of inspection process that need the experienced workers, and improves the inspection quality. This paper presents the primary study of image processing for RT-films that is the welding-film. The proposed approach to determine the defects on weld-images. The BMP image-files are opened and developed by computer program that using Borland C ++ . The software has five main methods that are Histogram, Contrast Enhancement, Edge Detection, Image Segmentation and Image Restoration. Each the main method has the several sub method that are the selected options. The results showed that the effective software can detect defects and the varied method suit for the different radiographic images. Furthermore, improving images are better when two methods are incorporated

  2. Radiographic and pathologic observations of eosinophilic gastroenteritis

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Lae Won [Busan Nationa University College of Medicine, Busan (Korea, Republic of); Hong, Sook Hee; Lee, Jung Dal [Busan Gospel Hospital, Busan (Korea, Republic of)

    1974-10-15

    This report presents two cases with eosinophilic gastroenteritis in detail. The radiographic and pathologic features of eosinophilic gastroenteritis are summarized with emphasis on the differential diagnostic features. Radiographic eosinophilic gastritis should be differentiated from gastric carcinoma and lymphoma, and eosinophilic enteritis from intestinal tuberculosis and intussusception of the small bowel in Korea where these entities are prevent. Eosinophilic gastroenteritis is pathologically characterized by diffuse infiltration of the submucosa and muscle coats with eosinophilic in conjunction with hypertrophy of individual muscle fibers. This leads to thickening of the gastrointestinal wall resulting in narrowing and obstruction of the lumen. Eosinophilic venulitis is another characteristic feature which is helpful for differentiation this entity from a parasitic infection.

  3. The radiographic examination of the colon

    International Nuclear Information System (INIS)

    Hendrix, T.R.; Saba, G.P. II.

    1980-01-01

    To provide medical and scientific background on certain selected technologies generally considered to be of particular significance, the National Center for Health Care Technology commissioned a series of overview papers, one of which is entitled 'The Radiographic Examination of the Colon.' These overviews are likely to be of most immediate interest to clinicians and biomedical scientists; they also may provide valuable background for assessments undertaken by the Center and for exploring the broad societal implications of health care technologies. Barium enema is the most available and widely used technique for examining the colon. It is often a routine part of the gastrointestinal work-up regardless of the suspected basis, anatomical or functional, of the patient's symptoms. Indeed, common practice is not to entertain a diagnosis of functional disorder before excluding all reasonable possibility of an anatomical abnormality. Barium enema is one of the most frequently ordered radiographic examinations

  4. MINAC, portable high energy radiographic inspection system

    International Nuclear Information System (INIS)

    Lapides, M.E.; Schonberg, R.

    1985-01-01

    MINAC, a portable, high energy radiographic source (1) was recognized as a desired inspection device for nuclear generation plants during EPRI-sponsored studies of the late 1970s and rapidly transitioned from proof-of-principle (1978-1980) to field-proven hardware (1981-present date). The equipment has completed its second generation of configuration development (SHRINKAC), that has recently been used in the field for detection of pipe cracks. Important auxiliaries for image data processing and real-time, thick section radiography have been demonstrated in both laboratory and field situations. Finally, a 6 MeV accelerator alternate is in bench test. These significant developments have, and are expected to continue to upgrade the utility of radiographic inspection in power plant practice. This paper describes the development and experience with this modular system during the last three years

  5. Radiographic and pathologic observations of eosinophilic gastroenteritis

    International Nuclear Information System (INIS)

    Jung, Lae Won; Hong, Sook Hee; Lee, Jung Dal

    1974-01-01

    This report presents two cases with eosinophilic gastroenteritis in detail. The radiographic and pathologic features of eosinophilic gastroenteritis are summarized with emphasis on the differential diagnostic features. Radiographic eosinophilic gastritis should be differentiated from gastric carcinoma and lymphoma, and eosinophilic enteritis from intestinal tuberculosis and intussusception of the small bowel in Korea where these entities are prevent. Eosinophilic gastroenteritis is pathologically characterized by diffuse infiltration of the submucosa and muscle coats with eosinophilic in conjunction with hypertrophy of individual muscle fibers. This leads to thickening of the gastrointestinal wall resulting in narrowing and obstruction of the lumen. Eosinophilic venulitis is another characteristic feature which is helpful for differentiation this entity from a parasitic infection

  6. Black Lung Benefits Act: standards for chest radiographs. Final rule.

    Science.gov (United States)

    2014-04-17

    Physicians and adjudicators use chest radiographs (X-rays) as a tool in evaluating whether a coal miner suffers from pneumoconiosis (black lung disease). Accordingly, the Department's regulations implementing the Black Lung Benefits Act allow the submission of radiographs in connection with benefit claims and set out quality standards for administering and interpreting film-based chest radiographs. This final rule updates the Department's existing film-radiograph standards and provides parallel standards for digital radiographs. This rule also updates outdated terminology and removes certain obsolete provisions.

  7. Chest radiographic manifestations of scrub typhus.

    Science.gov (United States)

    Abhilash, Kpp; Mannam, P R; Rajendran, K; John, R A; Ramasami, P

    2016-01-01

    Respiratory system involvement in scrub typhus is seen in 20-72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. The study cohort contained 398 patients. Common presenting complaints included fever (100%), generalized myalgia (83%), headache (65%), dyspnea (54%), cough (24.3%), and altered sensorium (14%). Almost half of the patients (49.4%) had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%), acute respiratory distress syndrome (14%), airspace opacity (10.5%), reticulonodular opacities (10.3%), peribronchial thickening (5.8%), and pulmonary edema (2%). Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89-33.16), invasive ventilation (OR: 18.07; 95% CI: 6.42-50.88), inotropes (OR: 8.76; 95% CI: 4.35-17.62), higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; Pscrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  8. The equine flexed lateral fetlock radiographic view

    International Nuclear Information System (INIS)

    Dyer, L.L.

    1993-01-01

    Recommendations for obtaining the flexed lateral radiographic view of the equine fetlock are provided. By tilting the X-ray tube in a 10-degrees dorsal direction, the angle of the flexed lateral fetlock joint is matched. While this view will not be effective on all horses, utilizing the flexed view aids in evaluating those horses that present an abnormal conformation when the fetlock joint is flexed

  9. Video enhancement of dental radiographic films

    International Nuclear Information System (INIS)

    Van Dis, M.L.; Beck, F.M.; Miles, D.A.

    1989-01-01

    A prototype video image display system, a real-time analog enhancer (RAE), was compared to conventional viewing conditions with the use of nonscreen dental films. When medium optical density films were evaluated, there was no significant difference in the number of radiographic details detected. Conventional viewing conditions allowed perception of more details when dark films were evaluated; however, the RAE unit allowed the perception of more details when light films were viewed

  10. Radiographic investigations during medico-legal autopsies

    Energy Technology Data Exchange (ETDEWEB)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-04-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described.

  11. An improved method for simulating radiographs

    International Nuclear Information System (INIS)

    Laguna, G.W.

    1986-01-01

    The parameters involved in generating actual radiographs and what can and cannot be modeled are examined in this report. Using the spectral distribution of the radiation source and the mass absorption curve for the material comprising the part to be modeled, the actual amount of radiation that would pass through the part and reach the film is determined. This method increases confidence in the results of the simulation and enables the modeling of parts made of multiple materials

  12. Intraligamentary--intraosseous anesthesia. A radiographic demonstration.

    Science.gov (United States)

    Garfunkel, A A; Kaufman, E; Marmary, Y; Galili, D

    1983-10-01

    Intraligamentary dental anesthesia has become a widely accepted technique. The periodontal ligament seems to provide easy access to the tooth apex. In the present study, radiopaque material was injected into baboon monkeys. Serial radiographs during incremental injections showed clouding of the crestal bone. The material was seen gradually advancing through the alveolar bone crest, apically. The spread was noticed through the marrow spaces, unexpectedly avoiding the PDL route.

  13. A radiographic anthology of vertebral names.

    Science.gov (United States)

    Yochum, T R; Hartley, B; Thomas, D P; Guebert, G M

    1985-06-01

    There are many conditions of the spine to which various authors have applied descriptive names. This paper, an extensive review of the literature, provides the first complete source for such named vertebrae. Included are 88 names covering all categories of bone disease. A brief description of the radiographic appearance and its pathogenesis is provided for each, along with a consideration of the disease processes which may produce the appearance.

  14. Radiographic imaging of the canine intercondylar fossa

    International Nuclear Information System (INIS)

    Montgomery, R.D.; Fitch, R.B.; Hathcock, J.T.; LaPrade, R.F.; Wilson, M.E.; Garrett, P.D.

    1996-01-01

    The intercondylar fossa is believed to play an important role in the pathology of cranial cruciate ligament rupture and therefore has received considerable attention in the last decade. Accurate radiographic imaging of the intercondylar fossa requires that the central x-ray beam pass through the center of the intercondylar “tunnel”. The anatomy of the canine intercondylar fossa is similar to humans, however, the orientations of the intercondylar fossa's differ. Consequently, the positioning techniques described for humans are not appropriate for the dog. To pass through the center of the dog, intercondylar fossa, the central x-ray beam should be 12° (S.D. 1.7°) caudal from the femoral diaphysis in the sagittal plane and obliqued caudolateral to craniomedial 7° (S.D. 0.60°) (caudo78°proximo7° lateralcraniodistomedial oblique). Cross table positioning was used with the hip flexed and the radiograph cassette placed on the cranial surface of the stifle. However, superimposition of the tuber ischii and soft tissues caudal to the femur made 15° to 20° the best angle obtainable. There was not a significant difference (p = 0.17) in the notch width index between a 12° versus 20° angle of the central x-ray beam caudal to the femoral diaphysis, both with 7° of external rotation of the stifle. The notch width index of 0.252 obtained from radiographic measurements was not significantly different from measurements obtained grossly of 0.254 (n = 26; p = 0.69). Failure to oblique the central x-ray beam caused a significant (p = 0.0008) decrease in the apparent fossa width radiographically

  15. The Society of Radiographers' research strategy

    International Nuclear Information System (INIS)

    Reeves, Pauline; Wright, Caroline; Shelley, Susan; Williams, Pat

    2004-01-01

    A research strategy for the Radiography (London 1995) profession was approved by the Council of the Society and College of Radiographers at the end of 2001.This paper discusses the formulation of that strategy, including the factors that lay behind its development. The recommendations of the strategy are then addressed one by one, together with a review as to their implementation by the College's Research Group

  16. Data acquisition system for radiographic imaging

    International Nuclear Information System (INIS)

    Lanza, R.C.; Votano, J.R.; Russ, T.

    1992-01-01

    This patent describes a continuous data acquisition system for radiographic imaging without interrupting acquisition activity the acquisition system. It comprises at least two memory means for storing radiographic data from a radiation detector wherein each of the memory means having a plurality of addressable memory locations and each of the memory means are such that the locations of the memory means correspond to spatial locations in the radiation detector; logic control means for sensing radiographic data transmitted by the radiation detector, for selecting one of the memory means for storage of the data, for transferring data to the selected memory means, and for switching form one memory means to another memory means according to a predefined schedule and according to memory capacity level, the logic control means further comprising a logic device which receives data and increments the contents of locations in a memory means in response to such data; and interface control means for reading data from one or the other memory means when such memory means is not actively acquiring data such that data can be acquired continuously by the system

  17. Nosocomial Legionnaires’ Disease: Clinical and Radiographic Patterns

    Directory of Open Access Journals (Sweden)

    Thomas J Marrie

    1992-01-01

    Full Text Available From 1981 to 1991, 55 patients (33 males, 22 females, mean age 58.6 years with nosocomial Legionnaires’ disease were studied. The mortality rate was 64%. One-half of the patients developed nosocomial Legionnaires’ disease within three weeks of admission. A surprising clinical feature was the low rate of findings of consolidation on physical examination, despite the fact that 52% of patients had this finding on chest radiograph. More than one-half of patients had pre-existing lung disease, rendering a radiographic diagnosis of pneumonia due to Legionella pneumophila impossible in 16% of cases despite microbiological confirmation. Nineteen per cent of patients who had blood cultures done had a pathogen other than L pneumophila isolated, suggesting dual infection in at least some of the patients. When the clinical and radiographic findings were combined it was noted that 40% of patients had one of three patterns suggestive of nosocomial Legionnaires’ disease: rapidly progressive pneumonia, lobar opacity and multiple peripheral opacities. However, in 60% of patients there were no distinctive features.

  18. Artificial intelligence for analyzing orthopedic trauma radiographs.

    Science.gov (United States)

    Olczak, Jakub; Fahlberg, Niklas; Maki, Atsuto; Razavian, Ali Sharif; Jilert, Anthony; Stark, André; Sköldenberg, Olof; Gordon, Max

    2017-12-01

    Background and purpose - Recent advances in artificial intelligence (deep learning) have shown remarkable performance in classifying non-medical images, and the technology is believed to be the next technological revolution. So far it has never been applied in an orthopedic setting, and in this study we sought to determine the feasibility of using deep learning for skeletal radiographs. Methods - We extracted 256,000 wrist, hand, and ankle radiographs from Danderyd's Hospital and identified 4 classes: fracture, laterality, body part, and exam view. We then selected 5 openly available deep learning networks that were adapted for these images. The most accurate network was benchmarked against a gold standard for fractures. We furthermore compared the network's performance with 2 senior orthopedic surgeons who reviewed images at the same resolution as the network. Results - All networks exhibited an accuracy of at least 90% when identifying laterality, body part, and exam view. The final accuracy for fractures was estimated at 83% for the best performing network. The network performed similarly to senior orthopedic surgeons when presented with images at the same resolution as the network. The 2 reviewer Cohen's kappa under these conditions was 0.76. Interpretation - This study supports the use for orthopedic radiographs of artificial intelligence, which can perform at a human level. While current implementation lacks important features that surgeons require, e.g. risk of dislocation, classifications, measurements, and combining multiple exam views, these problems have technical solutions that are waiting to be implemented for orthopedics.

  19. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Brandt, Andrew; Louw, Brand; Dekker, Gerrit; Andronikou, Savvas; Wieselthaler, Nicki; Kilborn, Tracy; Bertelsman, Jessica; Dreyer, Catherine

    2007-01-01

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  20. On being dyslexic: Student radiographers' perspectives

    International Nuclear Information System (INIS)

    Murphy, Fred

    2011-01-01

    The purpose of this paper was to provide an insight into life as a dyslexic student radiographer, identify barriers and risks in clinical training, and develop recommendations for the support of students with dyslexia. The paucity of research into dyslexia within the radiography profession is worrying, with attention focused only on the support provided by Higher Education Institutions (HEI) or inferences drawn from the experiences of other healthcare students. The impact and significance of dyslexia for student radiographers in clinical practice has never been investigated. Results: On a self-reporting scale of clinical tasks there was little or no difference between dyslexic students and non-dyslexics. Some minor traits commonly associated with dyslexics were also reported by students with no learning disabilities and an inclusion support plan for all students was advocated. In-depth interviews of 10 student radiographers revealed six distinct themes of visualising the disability, self-protection, strengths and talents, time, the badge of disability and adjustments and support. Like other healthcare students, some radiography students reported significant difficulties and prejudices and very little structured support in the clinical environment. Despite the Special Educational Needs and Disability Act being in place for several years, the support in clinical departments fell significantly short of that provided in the universities. The dyslexic students took extra responsibility for their own learning and some had developed complex coping strategies to overcome any difficulties. Conclusion: Several inclusive recommendations were developed as a result of this study that could be used to support all students on clinical placement.

  1. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  2. Segmentation of ribs in digital chest radiographs

    Science.gov (United States)

    Cong, Lin; Guo, Wei; Li, Qiang

    2016-03-01

    Ribs and clavicles in posterior-anterior (PA) digital chest radiographs often overlap with lung abnormalities such as nodules, and cause missing of these abnormalities, it is therefore necessary to remove or reduce the ribs in chest radiographs. The purpose of this study was to develop a fully automated algorithm to segment ribs within lung area in digital radiography (DR) for removal of the ribs. The rib segmentation algorithm consists of three steps. Firstly, a radiograph was pre-processed for contrast adjustment and noise removal; second, generalized Hough transform was employed to localize the lower boundary of the ribs. In the third step, a novel bilateral dynamic programming algorithm was used to accurately segment the upper and lower boundaries of ribs simultaneously. The width of the ribs and the smoothness of the rib boundaries were incorporated in the cost function of the bilateral dynamic programming for obtaining consistent results for the upper and lower boundaries. Our database consisted of 93 DR images, including, respectively, 23 and 70 images acquired with a DR system from Shanghai United-Imaging Healthcare Co. and from GE Healthcare Co. The rib localization algorithm achieved a sensitivity of 98.2% with 0.1 false positives per image. The accuracy of the detected ribs was further evaluated subjectively in 3 levels: "1", good; "2", acceptable; "3", poor. The percentages of good, acceptable, and poor segmentation results were 91.1%, 7.2%, and 1.7%, respectively. Our algorithm can obtain good segmentation results for ribs in chest radiography and would be useful for rib reduction in our future study.

  3. Chest radiographic manifestations of scrub typhus

    Directory of Open Access Journals (Sweden)

    KPP Abhilash

    2016-01-01

    Full Text Available Background and Rationale: Respiratory system involvement in scrub typhus is seen in 20–72% of patients. In endemic areas, good understanding and familiarity with the various radiologic findings of scrub typhus are essential in identifying pulmonary complications. Materials and Methods: Patients admitted to a tertiary care center with scrub typhus between October 2012 and September 2013 and had a chest X ray done were included in the analysis. Details and radiographic findings were noted and factors associated with abnormal X-rays were analyzed. Results: The study cohort contained 398 patients. Common presenting complaints included fever (100%, generalized myalgia (83%, headache (65%, dyspnea (54%, cough (24.3%, and altered sensorium (14%. Almost half of the patients (49.4% had normal chest radiographs. Common radiological pulmonary abnormalities included pleural effusion (14.6%, acute respiratory distress syndrome (14%, airspace opacity (10.5%, reticulonodular opacities (10.3%, peribronchial thickening (5.8%, and pulmonary edema (2%. Cardiomegaly was noted in 3.5% of patients. Breathlessness, presence of an eschar, platelet counts of 2 mg/dL had the highest odds of having an abnormal chest radiograph. Patients with an abnormal chest X-ray had a higher requirement of noninvasive ventilation (odds ratio [OR]: 13.98; 95% confidence interval CI: 5.89–33.16, invasive ventilation (OR: 18.07; 95% CI: 6.42–50.88, inotropes (OR: 8.76; 95% CI: 4.35–17.62, higher involvement of other organ systems, longer duration of hospital stay (3.18 ± 3 vs. 7.27 ± 5.58 days; P< 0.001, and higher mortality (OR: 4.63; 95% CI: 1.54–13.85. Conclusion: Almost half of the patients with scrub typhus have abnormal chest radiographs. Chest radiography should be included as part of basic evaluation at presentation in patients with scrub typhus, especially in those with breathlessness, eschar, jaundice, and severe thrombocytopenia.

  4. Automatic segmentation of vertebrae from radiographs

    DEFF Research Database (Denmark)

    Mysling, Peter; Petersen, Peter Kersten; Nielsen, Mads

    2011-01-01

    Segmentation of vertebral contours is an essential task in the design of automatic tools for vertebral fracture assessment. In this paper, we propose a novel segmentation technique which does not require operator interaction. The proposed technique solves the segmentation problem in a hierarchical...... is constrained by a conditional shape model, based on the variability of the coarse spine location estimates. The technique is evaluated on a data set of manually annotated lumbar radiographs. The results compare favorably to the previous work in automatic vertebra segmentation, in terms of both segmentation...

  5. Radiographic imaging system for high energy radiation

    International Nuclear Information System (INIS)

    1975-01-01

    A radiographic imaging system for high energy radiation is described utilizing a detector of such radiation and a mask having regions relatively transparent to such radiation and interspersed among regions relatively opaque to such radiation. A relative motion is imparted between the mask and the detector, the detector providing a time varying signal in response to the incident radiation and in response to the relative motion. The time varying signal provides, with the aid of a decoder, an image of a source of such radiation

  6. Improvements in or relating to radiographic apparatus

    International Nuclear Information System (INIS)

    Hounsfield, G.N.

    1978-01-01

    Radiographic apparatus is described for examining part of the interior of a body by means of penetrating radiation including a packing member comprising a bag containing particulate or viscous material, having an absorption to the radiation similar to that of human tissue, the member as a whole being flexible and being adapted to be placed in contact with the body in the vicinity of the part to be examined. Locating means, arranged to maintain the member in place, and means for disposing the locating means in a predetermined position with respect to the source of the radiation are provided. (author)

  7. Radiographic imaging system for high energy radiation

    International Nuclear Information System (INIS)

    Barrett, H.H.

    1976-01-01

    A radiographic imaging system for high energy radiation utilizing a detector of such radiation and a mask having regions relatively transparent to such radiation interspersed among regions relatively opaque to such radiation is described. A relative motion is imparted between the mask and the detector, the detector providing a time varying signal in response to the incident radiation and in response to the relative motion. The time varying signal provides, with the aid of a decoder, an image of a source of such radiation

  8. Radiographic investigations during medico-legal autopsies

    International Nuclear Information System (INIS)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-01-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described. (orig.) [de

  9. Radiographic analysis of temporomandibular joint arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo [Department of Oral Radiology, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1984-11-15

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  10. Radiographic film orientation in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Suchowerska, N.; Davison, A.; Drew, J.; Metcalfe, P.

    1996-01-01

    Since the discovery of x-rays, film has been used as a detection medium for radiation. More recently radiographic film has become established as a practical tool for the measurement of dose distribution in radiotherapy. The accuracy and reproducibility of film dosimetry depends on photon energy, processing conditions and film plane orientation. The relationship between photon energy, processing conditions and film dosimetry accuracy has been studied. The role of film plane orientation is still controversial. The current work aims to clarify the effects film plane orientation has on film dosimetry. Poster 205. (author)

  11. General-purpose radiographic and fluoroscopic table

    International Nuclear Information System (INIS)

    Ishizaki, Noritaka

    1982-01-01

    A new series of diagnostic tables, Model DT-KEL, was developed for general-purpose radiographic and fluoroscopic systems. Through several investigations, the table was so constructed that the basic techniques be general radiography and GI examination, and other techniques be optionally added. The diagnostic tables involve the full series of the type for various purposes and are systematized with the surrounding equipment. A retractable mechanism of grids was adopted first for general use. The fine grids with a density of 57 lines per cm, which was adopted in KEL-2, reduced the X-ray doses by 16 percent. (author)

  12. Revolutionizing radiographic diagnostic accuracy in periodontics

    Directory of Open Access Journals (Sweden)

    Brijesh Sharma

    2016-01-01

    Full Text Available Effective diagnostic accuracy has in some way been the missing link between periodontal diagnosis and treatment. Most of the clinicians rely on the conventional two-dimensional (2D radiographs. But being a 2D image, it has its own limitations. 2D images at times can give an incomplete picture about the severity or type of disease and can further affect the treatment plan. Cone beam computed tomography (CBCT has a better potential for detecting periodontal bone defects with accuracy. The purpose here is to describe how CBCT imaging is beneficial in accurate diagnosis and will lead to a precise treatment plan.

  13. Normal radiographic findings. 4. act. ed.

    International Nuclear Information System (INIS)

    Moeller, T.B.

    2003-01-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  14. Radiographic analysis of temporomandibular joint arthrosis

    International Nuclear Information System (INIS)

    You, Dong Soo

    1984-01-01

    The author analysed the bone changes, the positional relationships between condylar head and articular fossa, and the interrelationship between the bone changes and the abnormal position of condylar head, from 1,036 radiographs of 259 patients with temporomandibular joint arthrosis, which were obtained by the oblique-lateral transcranial projection and orthopantomograms. The results were as follows: 1. Among the radiographic bone changes of the temporomandibular joint arthrosis, deformity was 36..90% (217 cases), sclerosis 34.18% (201 cases), erosive change 25.58% (152 cases) and marginal proliferation 3.06% (18 cases) respectively. 2. In the positional changes between condylar head and articular fossa, the downward positioning of condylar head in centric occlusion was most frequent (36.90%), of which frequency was significantly higher than forward positioning (11.22%) and backward positioning (4.76%) in same condition. Also, radiographs showed that the enlargement of articular space showed higher frequency than its narrowing. In the opening position of mouth, the restrict ed movement of condylar head within articular fossa was most frequent (35.03%). The forward positioning and the downward positioning was 15.65% and 9.52% respectively. Also, radiographs revealed that the incomplete movement or no positional change of condylar head was most frequent. 3. In the interrelationship between bone changes and abnormal position of condylar head, deformity was 42.79% in the cases of downward positioning of condylar head in centric occlusion and 37.50% in those of normal positioning of condylar head in same condition. This revealed that deformity was most frequent bone change in above condylar positionings. However, erosive change was 34.62% in the cases of downward positioning of condylar head in centric occlusion and 33 .33% in those of forward positioning. In opening position of condylar head, and deformity in the cases of norma l positioning, forward positioning and

  15. Normal radiographic findings. 4. act. ed.; Roentgennormalbefunde

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, T.B. [Gemeinschaftspraxis fuer Radiologie und Nuklearmedizin, Dillingen (Germany)

    2003-07-01

    This book can serve the reader in three ways: First, it presents normal findings for all radiographic techniques including KM. Important data which are criteria of normal findings are indicated directly in the pictures and are also explained in full text and in summary form. Secondly, it teaches the systematics of interpreting a picture - how to look at it, what structures to regard in what order, and for what to look in particular. Checklists are presented in each case. Thirdly, findings are formulated in accordance with the image analysis procedure. All criteria of normal findings are defined in these formulations, which make them an important didactic element. (orig.)

  16. Contribution to identification of factors causing radiographic image unsharpness

    International Nuclear Information System (INIS)

    Branzan, C.; Popescu, A.; Radu, R.

    1995-01-01

    Radiographic image quality is crucial for the ability of the radiographic method to give us a maximum information about the macroscopic structure of materials and pieces, investigated by penetrating radiation. Radiographic image quality depends on several factors. A high quality image is able to show small and typical defects. One of the most important factor affecting radiographic image is unsharpness. The total effective unsharpness of the film must be some function of several factors and their contribution is taken into account by summing up different kinds of unsharpness: geometric unsharpness, internal unsharpness, screen unsharpness, and accidental unsharpness. This work analyses the weight of the radiographic image unsharpness and the possibilities for determining its influence on the quality of the radiographic image. (author)

  17. Commitment of the radiographer - does it matter to the patient?

    International Nuclear Information System (INIS)

    Blagoeva, D.; Shuleva, L.; Goudeva, V.; Stoinova, V.

    2015-01-01

    Full text: Radiographers are responsible for providing safe and accurate imaging examinations in a wide range of clinical environments, using a variety of imaging modalities and techniques so that appropriate management and treatment of patients and clients can proceed. The purpose of this presentation is to discuss: the responsibilities of radiographer in the clinical radiology department; their professional judgment to decide how to achieve a diagnostic outcome; the relationship patient/radiographer; the impact of the radiographer on patient care. Patient care and advocacy has always been an integral part of the radiography profession. The radiographer should respect the patient at all the times, be genuine in nature and empathies with the patient‘s condition. Good listening and observational skills are also very important components. The radiographers are personally accountable for their work and professional conduct

  18. Radiographic evaluation of coxofemoral joint laxity in dogs part I: New stress-radiographic positioning techniques

    International Nuclear Information System (INIS)

    Phiwipha Kamonrat; Duangdaun Kaenkangploo

    2002-01-01

    Two new stress-radiographic positioning techniques, namely 60 deg and 90 deg stress techniques, were introduced for quantifying hip joint laxity in dogs. The comparative characteristics and efficiency of these new techniques with angled hindlimbs were evaluated relative to the standard hip-extended radiographic technique. Forty, healthy, mongrel dogs with normal hip joint conformation were anesthetized and placed in dorsal recumbency before 3 radiograhps of the standard, 60 deg , and 90 deg stress techniques were taken. For the 60 deg stress technique, hindlimbs were extended in parallel to each other at 60 deg angled to the table top and stifles were slightly rotated inward, femoral heads were manually pushed in a craniodorsal direction during exposure. For the 90 deg stress technique, femurs were positioned perpendicular to the table top, stifles were 90 deg flexed and adducted and femoral heads were manually pushed in a craniodorsal direction during exposure. The subluxation index (SI) and dorsolateral subluxation score (DLS score) were calculated from 3 radiographic views for both hip joints to quantitate the relative degree of joint laxity. Results of the study indicated that the 60 deg (SI = 0.20+-0.045, DLS score = 62.5+-7.96 percent) and 90 deg (SI = 0.23+-0.044, DLS score = 61.2+-9.47 percent) stress-radiographs yielded significantly (p0.001) higher degree of hip joint laxity than the standard technique (SI)

  19. Radiographic analysis of partial or total vertebral body resection

    International Nuclear Information System (INIS)

    Whitten, C.G.; Hammer, G.H.; El-Khoury, G.Y.; Hugus, J.; Weinstein, J.N.

    1991-01-01

    Partial and total vertebrectomies are used in the treatment of primary and metastatic neoplasms of the spine. Serial radiographic studies are crucial in the follow-up of patients with vertebrectomies. This paper presents 33 cases and illustrates radiographic examples of both successful and complicated vertebrectomies, including radiographic signs of local tumor recurrence, loosening, migration or fracture of the hardware or methylmethacrylate, bone graft failure, and progressive spinal instability

  20. Xeroradiographic and radiographic anatomy of the channel catfish, Ictalurus punctatus

    International Nuclear Information System (INIS)

    Smith, S.A.; Smith, B.J.

    1994-01-01

    The purpose of this study was to provide an anatomic reference for the channel catfish (Ictalurus punctatus) using xeroradiography† and conventional radiography. The entire body of three adult fish was radiographed using standard xeroradiographic and conventional radiographic techniques. Two xeroradiographs and their corresponding conventional radiographs were selected, and the xeroradiographs labeled to illustrate the normal skeletal and soft-tissue anatomy of the channel catfish

  1. Occupational stress and its predictors in radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, D.R. [Centre for Research in Health Behaviour, Department of Psychology, University of Kent, Keynes College, Canterbury CT2 7NP (United Kingdom)], E-mail: d.r.rutter@kent.ac.uk; Lovegrove, M.J. [Department of Allied Health Professions, London South Bank University, London SE1 0AA (United Kingdom)

    2008-05-15

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it.

  2. Radiographic film: surface dose extrapolation techniques

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW; Currie, M.

    2004-01-01

    Full text: Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate 2 dimensional map of surface dose if required. Results have shown that surface % dose can be estimated within ±3% of parallel plate ionisation chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10cm, 20cmand 30cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. Corresponding parallel plate ionisation chamber measurement are 16%, 27% and 37% respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  3. Radiographic Control of 137-Cs Brachytherapy Sources

    International Nuclear Information System (INIS)

    Bistrovic, M.; Viculin, T.; Jurkovic, S.

    2003-01-01

    1 37C s brachytherapy sources are practical for the intracavitary application due to their relatively long lifetime (T 1/2 = 30 y). On the other hand, due to the relatively low energy (0.66 MeV) of the emitted photons, they are suitable for an efficient radiation protection. The dose distribution around the sources is usually calculated by a specific program. However this program requires the knowledge of the position of sources within the applicator as well as the distribution of activity along them. The only way to learn these data is to make an X-ray picture of applicators and sources superimposed to the autoradiography of every source. It is difficult to achieve satisfactory radiographs with high dose rate sources with standard X-ray film material because autoradiography covers the structure of the radiographic shadow. The problem can be overcome either by applying a high intensity X-ray or gamma beam (originating from a radiotherapeutic machine), or by using photographic material of very low sensitivity, for example photographic paper. Combining both possibilities one can obtain satisfactory images. (author)

  4. Lead arthropathy: radiographic, CT and MRI findings

    International Nuclear Information System (INIS)

    Fernandes, Joao Luiz; Lopes Rocha, Arthemizio Antonio; Veloso Ayrimoraes Soares, Mayra; Lopes Viana, Sergio

    2007-01-01

    Lead arthropathy is a well-known complication of gunshot injuries with retained intra-articular bullets. Although several previous reports have discussed the radiological findings of this entity, computed tomography (CT) and magnetic resonance imaging (MRI) findings have never been described before in this setting. In this paper the authors review the imaging findings of 11 patients with lead arthropathy (1 of whom had clinical signs of lead poisoning as well), all of them studied by means of radiographs. In addition, non-enhanced CT scans were obtained in 3 patients and gadolinium-enhanced MRI in 1. Classic findings of intra-articular speckled lead deposits (occasionally with a ''lead arthrogram'' appearance), joint space narrowing and preserved bone density were found at radiographs in the great majority of cases. Furthermore, extension of intra-articular lead to adjacent tendon sheaths was observed in almost half of the patients, an observation rarely reported in the literature. CT scans and MRI, in their turn, were superior with regard to soft tissue abnormalities, accurately depicting joint effusion and the thickened synovium with lead particles embedded in it. Post-gadolinium MRI had the advantage of showing the enhancement pattern of the inflamed synovium and associated bone marrow edema pattern. Although it is not possible to establish the role of axial imaging in lead arthropathy from the small number of cases studied, this initial experience shows that both methods hold promise in this setting and may be useful, at least in selected cases. (orig.)

  5. Occupational stress and its predictors in radiographers

    International Nuclear Information System (INIS)

    Rutter, D.R.; Lovegrove, M.J.

    2008-01-01

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it

  6. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  7. Necrotizing fasciitis : plain radiographic and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Dae; Park, Jeong Hee; Jeon, Hae Jeong; Lim, Jong Nam; Heo, Tae Haeng; Park, Dong Rib [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate the plain radiographic and CT findings of the necrotizing fasciitis. We retrospectively reviewed the radiologic findings of 4 cases with necrotizing fasciitis. Three cases were proven pathologically. We evaluated pattern and extent of the gas shadows in plain films. CT findings were analysed, with emphasis on : (a) gas pattern, (b) extent, (c) location and involved site, (d) associated focal abscess, and (e) swelling of the adjacent muscles. On plain radiographs, four cases showed streaky or mottled gas densities in the pelvis, three cases in the perineum, one case in the abdomen, and two cases in the thigh. On CT images, gas pattern was mottled and streaky appearance with swelling of the adjacent muscles. Gas shadows located in the extraperitoneal space in four cases, fascial layer in four cases, and subcutaneous layer in four cases. There were gas shadows in pelvic wall, perineum, abdominal wall, buttock, thigh, and scrotum. Focal low density lesion suggestive of focal abscess was not visualized. Plain radiography is useful for early diagnosis of the necrotizing fasciitis and CT is very useful for detection of precise location and extent of the disease. CT is also useful for differentiation of necrotizing fasciitis from focal abscess and cellulitis.

  8. MRI and radiographic findings in Currarino's triad

    International Nuclear Information System (INIS)

    Pfluger, T.; Czekalla, R.; Koletzko, S.; Muensterer, O.; Willemsen, U.F.; Hahn, K.

    1996-01-01

    Currarino's triad is a rare complex of a congential sacral bony abnormality, anorectal malformation and a presacral mass. Intractable constipation since birth is the leading symptom of this triad, which follows an autosomal dominant mode of heredity. We report conventional radiographic and MR findings in one family consisting of a mother and her two daughters. In all three cases, radiography revealed an abnormality of the os sacrum, the so-called scimitar sacrum. MR examination, undertaken next in our institution, was applied with T1-, T2- and proton density weighted sequences in all three orientations before and after i.v. application of gadolinium diethylene-triamine-pentaacetic acid (Gd-DTPA). In two patients we were able to diagnose the complete form of the triad and in one patient an incomplete form. In any case of a radiographically diagnosed scimitar sacrum in combination with constipation. Currarino's triad should be considered. MRI, as the method of choice, should be the next step to detect a presacral mass and any anomalies of the spinal canal. The importance of early recognition lies in the high morbidity and mortality rates resulting from this disorder. (orig.)

  9. Monte Carlo simulation for radiographic applications

    International Nuclear Information System (INIS)

    Tillack, G.R.; Bellon, C.

    2003-01-01

    Standard radiography simulators are based on the attenuation law complemented by built-up-factors (BUF) to describe the interaction of radiation with material. The assumption of BUF implies that scattered radiation reduces only the contrast in radiographic images. This simplification holds for a wide range of applications like weld inspection as known from practical experience. But only a detailed description of the different underlying interaction mechanisms is capable to explain effects like mottling or others that every radiographer has experienced in practice. The application of Monte Carlo models is capable to handle primary and secondary interaction mechanisms contributing to the image formation process like photon interactions (absorption, incoherent and coherent scattering including electron-binding effects, pair production) and electron interactions (electron tracing including X-Ray fluorescence and Bremsstrahlung production). It opens up possibilities like the separation of influencing factors and the understanding of the functioning of intensifying screen used in film radiography. The paper discusses the opportunities in applying the Monte Carlo method to investigate special features in radiography in terms of selected examples. (orig.) [de

  10. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  11. Reflections on the role of consultant radiographers in the UK: What is a consultant radiographer?

    International Nuclear Information System (INIS)

    Booth, L.; Henwood, S.; Miller, P.

    2016-01-01

    Context: This paper is the second paper from a two year in depth case study, exploring the role of consultant radiographers in the UK. Methods: A longitudinal case study approach was used to determine the role of consultant radiographers. Interviews were used to explore experiences of being a consultant, which were analysed using thematic analysis. Eight consultant radiographers participated (Note, two of the consultants withdrew after the first interview due to workload). Therefore two consultants were interviewed only once. The remaining six consultants were interviewed twice over a 12 month period. Findings: The data presented in this paper explores the nature of the role, differences between roles, the four domains of practice, and how the role fits into local organisational structures. The study shows wide variation in the types of roles undertaken, reflecting that the creation of these roles were in response to local clinical need and often related to an individual practitioner's skills. The broad scope of the role was shown across all the consultants, with evidence of roles developing into new areas of service delivery. Conclusions: The paper offers insight into the role(s) of consultant radiographers in the UK. The range and scope of their practice is extensive, with much variation. It is evident that the clinical aspect of the role dominates, with research being the least supported domain of practice. There remains a lack of clarity around the role, with concerns about remuneration and other limitations that may restrict the role developing further. - Highlights: • This paper shows the variation in roles between consultant radiographers. • The commonality with medical roles is highlighted. • Problem solving is identified as a core skill in consultant radiography. • Consultants offered evidence of the roles developing service provision. • While all four domains of practice are covered, research is the least well supported.

  12. Common pitfalls in radiographic interpretation of the Thorax

    International Nuclear Information System (INIS)

    Godshalk, C.P.

    1994-01-01

    Errors in radiographic interpretation of the thorax are common. Many mistakes result from interpreting normal anatomic variants as abnormalstructures, such as misdiagnosing dorsal and rightward deviation of the cranial thoracic trachea on lateral radiographs of normal dogs. Some of the more common errors specifically relate to misinterpretation of radiographs made on obese patients. The age of the patient also plays a role in misdiagnosis. Aging cats seem to have a horizontally positioned heart on lateral radiographs, and older dogs, primarily collies,often have pulmonary osteomas that are misdiagnosed as metastatic neoplastic disease or healed pulmonary fungal infections

  13. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  14. Radiographic evaluation of dentigerous cyst with cone beam CT

    International Nuclear Information System (INIS)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do

    2010-01-01

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  15. Radiographic evaluation of dentigerous cyst with cone beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yong Chan; Lee, Wan; Lee, Byung Do [School of Dentisity, Wonkwang University, Iksan (Korea, Republic of)

    2010-09-15

    The purpose of this study was to accurately analyze the radiographic characteristics of dentigerous cyst (DC) with multiplanar images of cone beam computed tomography (CBCT). Thirty eight radiographically and histopathologically proven cases of DCs were analyzed with panoramic radiograph and CBCT, retrospectively. The radiographic CT pattern, symmetry of radiolucency around the unerupted tooth crown, ratio of long length to short length, degree of cortical bone alternation, effects on adjacent tooth, and cyst size were analyzed. Relative frequencies of these radiographic features were evaluated. In order to compare the CBCT features of DC with those of odontogenic keratocyst (OKC), 9 cases of OKCs were analyzed with the same method radiographically. DCs consisted of thirty unilocular cases (79.0%), seven lobulated cases (18.4%) and one multilocular case (2.6%). Eight were asymmetric (21.0%) and thirty were symmetric (79.0%). Maxillary DC showed rounder shape than mandibular DC (L/S ratio; maxilla 1.32, mandible 1.67). Alternations of lingual cortical bone (14 cases, 48.2%) were more frequent than those of buccal side (7 cases, 24.1%). CBCT images of DC showed definite root resorption and bucco-lingual tooth displacement. These findings were hardly observed on panoramic radiographs of DCs. Comparison of CBCT features of DC with those of OKC showed several different features. CBCT images of DC showed various characteristic radiographic features. Therefore, CBCT can be helpful for the diagnosis of DC radiographically.

  16. Radiographic aspects of Pneumocystis carinii pneumonia in the miniature dachshund

    International Nuclear Information System (INIS)

    Kirberger, R.M.; Lobetti, R.G.

    1998-01-01

    The thoracic radiographic changes of Pneumocystis carinii in 7 miniature Dachshunds were reviewed, The dogs were 7-12 months old and presented with polypnea, exercise intolerance and clinical signs suggestive of immune-incompetence. P. carinii pneumonia was diagnosed in all the dogs using transtracheal aspirate cytology and confirmed at postmortemin 3 dogs that died. Radiographically, diffuse pulmonary changes we represent and varied from a mild interstitial and bronchial pattern to an alveolar pattern. Radiographic evidence of cor pulmonale was present in 1 dog. The most severe radiographic changes were seen in 2 of the dogs that died

  17. Radiographic anatomy of the medial coronoid process of dogs

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Takiguchi, M.; Schrader, S.C.; Biller, D.S.

    1995-01-01

    Mediolateral, flexed mediolateral, mediocaudal-laterocranial 15 degrees oblique (extended and supinated mediolateral), and craniolateral-caudomedial 20 degrees to 30 degrees oblique radiographs of 16 elbow-joint specimens were produced to study the radiographic anatomy of the medial coronoid process. On the mediolateral view, the cranial point of the coronoid process was at the level of the distal one-third of the radial epiphysis. Degree of superimposition of the proximal radius and ulna determined how the medial coronoid process was projected on the radiographs. Mediocaudal-laterocranial oblique radiographs best showed the cranial outline of the medial coronoid process with moderate superimposition of the proximal radius and ulna

  18. Radiographic caries diagnosis and restorative treatment decision making

    International Nuclear Information System (INIS)

    Mileman, P.A.

    1985-01-01

    This thesis is concerned with a single diagnostic technique: the bitewing radiograph, and the way it is used by dentists to decide on patient treatment need for interproximal caries. The variation in caries diagnosis and treatment decisions using bitewing radiographs is described and the radiographic criteria of choice for minimizing over and undertreatment according to a norm are investigated. Three possible diagnostic strategies in interproximal caries diagnosis using a decision analysis approach are described and evaluated, and the effect of the reported diagnostic behaviour and knowledge of practicing Dutch dentists in their use of bitewing radiographs for the diagnosis and treatment of interproximal caries is described and analyzed. (Auth.)

  19. Simulated radiographic bone and joint modeling from 3D ankle MRI: feasibility and comparison with radiographs and 2D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Nordeck, Shaun M. [University of Texas Southwestern Medical College, Dallas, TX (United States); University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Koerper, Conrad E.; Adler, Aaron [University of Texas Southwestern Medical College, Dallas, TX (United States); Malhotra, Vidur; Xi, Yin [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); Liu, George T. [University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States); Chhabra, Avneesh [University of Texas Southwestern Medical Center, Musculoskeletal Radiology, Dallas, TX (United States); University of Texas Southwestern Medical Center, Orthopaedic Surgery, Dallas, TX (United States)

    2017-05-15

    The purpose of this work is to simulate radiographs from isotropic 3D MRI data, compare relationship of angle and joint space measurements on simulated radiographs with corresponding 2D MRIs and real radiographs (XR), and compare measurement times among the three modalities. Twenty-four consecutive ankles were included, eight males and 16 females, with a mean age of 46 years. Segmented joint models simulating radiographs were created from 3D MRI data sets. Three readers independently performed blinded angle and joint space measurements on the models, corresponding 2D MRIs, and XRs at two time points. Linear mixed models and the intraclass correlation coefficient (ICC) was ascertained, with p values less than 0.05 considered significant. Simulated radiograph models were successfully created in all cases. Good agreement (ICC > 0.65) was noted among all readers across all modalities and among most measurements. Absolute measurement values differed between modalities. Measurement time was significantly greater (p < 0.05) on 2D versus simulated radiographs for most measurements and on XR versus simulated radiographs (p < 0.05) for nearly half the measurements. Simulated radiographs can be successfully generated from 3D MRI data; however, measurements differ. Good inter-reader and moderate-to-good intra-reader reliability was observed and measurements obtained on simulated radiograph models took significantly less time compared to measurements with 2D and generally less time than XR. (orig.)

  20. Performance evaluation of real time radiographic systems

    International Nuclear Information System (INIS)

    Venkatraman, B.; Saravanan, S.; Jayakumar, T.; Kalyanasundaram, P.; Baldev Raj

    1996-01-01

    The Real Time Radiography (RTR) system can be studied completely by knowing the modulation transfer function (MTF) of the whole system. The MTF curve is a special form of contrast/detail-size diagram in which the image contrast is plotted against the spatial frequency of a test object measured in line-pairs per millimetre (lp/mm). MTF curves are widely used to measure the characteristics of optical equipment, particularly for assessing the contribution of individual items in a complex imaging transfer system. Codes of practice indicate that the image intensifier systems should be checked periodically to assess its performance through the use of MTF curves and step wedges for contrast ratio. Authors, instead, suggest the use of performance curves which are simple to obtain and can be easily interpreted by radiographers. (author)

  1. Radiographic studies of the ventricles in syringomyelia

    International Nuclear Information System (INIS)

    West, R.J.; Williams, B.

    1980-01-01

    Radiographic investigations of 171 patients with communicating syringomyelia have been reviewed. Hydrocephalus was found in one third of the cases and has occasionally progressed after operation on the posterior fossa, sometimes with accompanying clinical deterioration. The outlets of the fourth ventricle were usually abnormal; tonsillar descent, arachnoiditis and both together were seen. Arachnoiditis correlated strongly with a history of difficult birth. The foramen of Magendie was sometimes patent and sometimes blocked. There was no consistent level of occulusion corresponding to a persistent roof of the fourth ventricle. The cisterna magna was usually small or obliterated but some examples of large cisterns or subarachnoid pouches were found. Radiological demonstration of a communication from the fourth ventricle to the syrinx occurred in only seven patients by positive contrast material and not by air. It is suggested that a sizable communication is rare at the time when patients seek treatment. (orig.)

  2. Predictive value of radiographic findings in gastritis

    International Nuclear Information System (INIS)

    Remley, K.B.; Mann, F.A.; Simons, M.A.

    1986-01-01

    In a retrospective review of biphasic upper gastrointestinal (GI) tract examinations in 300 consecutive patients with abdominal pain, blood loss, nausea and vomiting, weight loss or dysphagia, the author evaluated the frequency of radiographic findings suggestive of gastritis. Forty-eight patients had undergone endoscopy within 1 week of upper GI tract examination. ''Best findings'' were defined by receiver operating characteristic wave analysis of individual findings, including aphthous lesions, serrated or nodular folds, marginal spiculation, and luminal constriction. Most false negative studies were in the fundus or proximal body; most false positive studies were in the antrum. They present a pictorial dictionary of findings and data for use of ''best findings'' to improve sensitivity and specificity in the diagnosis of gastritis

  3. Chest radiographic findings of tuberculous pneumonia

    International Nuclear Information System (INIS)

    Jung, Seung Hye; Sung, Dong Wook; Yoon, Yup; Lim, Jae Hoon

    1991-01-01

    When tuberculous pneumonia appears as a segmental or loabr consolidation, its is difficult to differentiate tuberculous pneumonia from nontuberculous bacterial pneumonia radiologically. The object of this study was to define the typical radiographic findings of tuberculous pneumonia through comparative analysis of tuberculous and nontuberculous pneumonia. A review of chest radiolograph in 29 patients with tuberculous pneumonia and in 23 patients with nontuberculous bacterial pneumonia was made with regard to homogeneity, volume loss, air-fluid level within the cavities, air-bronchogram, pleural disease, and predilection sites. The characteristic findings of tuberculous pneumonia are a heterogeneous density of infiltration (66%), evidence of volume loss of infiltrative lesion (52%), and cavity formation (48%) without air - fluid level. An associated parameter of analysis is the relative absence of leukocytosis (76%)

  4. Radiographer perceptions of managerial transformational leadership levels.

    Science.gov (United States)

    Legg, Jeffrey S; Akroyd, Duane; Jackowski, Melissa B

    2010-01-01

    Transformational leadership focuses on the ability of a leader to impact employees by inspiring employees to broaden interests in work as well as to be innovative and creative. It is positively associated with employee satisfaction and commitment to the organization. Characteristics of transformational leaders include confidence, ability to mange and deal with complexity, and belief in their employees and organizations. Considering the importance of leadership skills in radiology departments, this paper addresses directly the empirical evidence concerning radiographer's perception of their radiology managers and supervisors transformational leadership levels in the United States. Leadership can be taught, and we as a profession must begin to implement leadership training programs for our current and future leaders.

  5. Radiographic examination takes on an automated image

    International Nuclear Information System (INIS)

    Aman, J.

    1988-01-01

    Automation can be effectively applied to nondestructive testing (NDT). Until recently, film radiography used in NDT was largely a manual process, involving the shooting of a series of x-rays, manually positioned and manually processed. In other words, much radiographic work is being done the way it was over 50 years ago. Significant advances in automation have changed the face of manufacturing, and industry has shared in the benefits brought by such progress. The handling of parts, which was once responsible for a large measure of labor costs, is now assigned to robotic equipment. In nondestructive testing processes, some progress has been achieved in automation - for example, in real-time imaging systems. However, only recently have truly automated NDT begun to emerge. There are two major reasons to introduce automation into NDT - reliability and productivity. Any process or technique that can improve the reliability of parts testing could easily justify the capital investments required

  6. Radiographic manifestations of reperfusion edema after transplantation

    International Nuclear Information System (INIS)

    Park, Se Young; Kim, Tae Hoon; Ryu, Young Hoon; Moon, Sung Wook; Kim, Hyung Joong; Ahn, Chul Min; Paik, Hyo Chae; Lee, Doo Yun; Kim, Sang Jin

    2003-01-01

    To elucidate the sequential radiologic manifestations of reperfusion edema after lung transplantation. The study group comprised five consecutive lung transplant recipients (M:F=3:2;mean age; 47.5 years) who between July 1996 and April 2002 underwent lung transplantation procedures (four, unilateral; one, bilateral) at our institution. We retrospectively reviewed the serial postoperative radiographs obtained and characterized the lung infiltrates. Lung infiltrates compatible with reperfusion edema were present in all patients (5/5). Reperfusion edema appeared on day 1 in four, and by day 2 in the other. In all transplanted lungs, infiltrates were found in the perihilar and basilar regions, and were scored as maximal on day 1 in one, day 3 in two, day 4 in one and day 5 in the other. The recognition of sequential radiological manifestations helps identify recognition of reperfusion edema after lung transplantation

  7. The radiographic observation of the cervical strain

    International Nuclear Information System (INIS)

    Rhee, Chung Sik

    1972-01-01

    A total of 100 cases of cervical disorders were analysed of clinical signs and symptoms. The cervical strain is proved by the loss of normal lordotic curvature of the cervical spinal column on the lateral x-ray film in Ewha University Hospital from January, 1970 to december 1971 with the following results. 1. The 53 cervical strain was diagnosed in radiographic study for its abnormal locations. The hyperextension with abnormal curve is twice more after than hyperflection type. 2. The most frequent location of the cervical strain is demonstrated in the 4-6 th cervical spinal bodies (80%). 3. Most pronounced symptoms of cervical strain are local tenderness (40%), limitation of motion (17%) and radiating pain (15%). 4. The ratio of the sex incidence of male female was 3:2

  8. The radiographic observation of the cervical strain

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Chung Sik [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    1972-12-15

    A total of 100 cases of cervical disorders were analysed of clinical signs and symptoms. The cervical strain is proved by the loss of normal lordotic curvature of the cervical spinal column on the lateral x-ray film in Ewha University Hospital from January, 1970 to december 1971 with the following results. 1. The 53 cervical strain was diagnosed in radiographic study for its abnormal locations. The hyperextension with abnormal curve is twice more after than hyperflection type. 2. The most frequent location of the cervical strain is demonstrated in the 4-6 th cervical spinal bodies (80%). 3. Most pronounced symptoms of cervical strain are local tenderness (40%), limitation of motion (17%) and radiating pain (15%). 4. The ratio of the sex incidence of male female was 3:2.

  9. Low grade gastric MALT lymphoma: Radiographic findings

    International Nuclear Information System (INIS)

    Brown, J.A.; Carson, B.W.; Gascoyne, R.D.; Cooperberg, P.L.; Connors, J.M.; Mason, A.C.

    2000-01-01

    AIMS: Gastric MALT (mucosa-associated lymphoid tissue) lymphoma is now recognized as a distinct entity within extranodal non-Hodgkin's lymphoma. The purpose of this study was to describe the radiographic findings in low grade gastric MALT lymphoma. MATERIALS AND METHODS: We retrospectively reviewed the radiographic findings in 22 cases of low-grade gastric MALT lymphoma. The study group consisted of 15 men and seven women (median age 68 years, range 41-91 years). Lesions were designated as infiltrative or polypoid by consensus of two radiologists. Polypoid lesions were categorized by number and size. Anatomical site within the stomach and presence of transpyloric or oesophagogastric extension was determined for each case. The presence of abdominal lymphadenopathy was categorized as regional or distant. The presence of Helicobacter pylori was determined from endoscopic and surgical biopsies. RESULTS: Computed tomography (CT) revealed abnormalities of the stomach in 19 cases of the 21 in which it was performed. There were 14 infiltrative lesions and five polypoid lesions. Of the 14 infiltrative lesions, the mean gastric wall thickness was 2.2 cm (range 0.8-6.0 cm). There were three single and two multiple polypoid lesions (mean size 2.2 cm, range 1.5-2.7 cm). Transpyloric extension was observed in two cases and oesophagogastric extension in one. Abdominal lymphadenopathy was observed in 10 of 21 patients. Helicobacter pylori was found in 19 of 22 cases (86%). CONCLUSION: Low grade B cell gastric MALT lymphomas present with an infiltrative form on CT in about three-quarters of cases and a polypoid pattern in the remainder. Abdominal lymphadenopathy is seen in approximately one-half of cases. There is a high association with Helicobacter pylori. Brown, J.A. 2000. Clinical Radiology 55, 384-389

  10. Radiographic outcomes among South African coal miners.

    Science.gov (United States)

    Naidoo, Rajen N; Robins, Thomas G; Solomon, A; White, Neil; Franzblau, Alfred

    2004-10-01

    This study, the first to document the prevalence of pneumoconiosis among a living South African coal mining cohort, describes dose-response relationships between coal workers' pneumoconiosis and respirable dust exposure, and relationships between pneumoconiosis and both lung function deterioration and respiratory symptoms. A total of 684 current miners and 188 ex-miners from three bituminous-coal mines in Mpumalanga, South Africa, was studied. Chest radiographs were read according to the International Labour Organization (ILO) classification by two experienced readers, one an accredited National Institute for Occupational Safety and Health (NIOSH) "B" reader. Interviews were conducted to assess symptoms, work histories (also obtained from company records), smoking, and other risk factors. Spirometry was performed by trained technicians. Cumulative respirable dust exposure (CDE) estimates were constructed from historical company-collected sampling and researcher-collected personal dust measurements. kappa-Statistics compared the radiographic outcomes predicted by the two readers. An average profusion score was used in the analysis for the outcomes of interest. Because of possible confounding by employment status, most analyses were stratified on current and ex-miner status. The overall prevalence of pneumoconiosis was low (2%-4%). The degree of agreement between the two readers for profusion was moderate to high (kappa=0.58). A significant association (Pminers only. A significant (Pminers with pneumoconiosis than among those without. Logistic regression models showed no significant relationships between pneumoconiosis and symptoms. The overall prevalence of pneumoconiosis, although significantly associated with CDE, was low. The presence of pneumoconiosis is associated with meaningful health effects, including deterioration in lung function. Intervention measures that control exposure are indicated, to reduce these functional effects.

  11. Mentoring assistant practitioners - The radiographer's perspective

    International Nuclear Information System (INIS)

    Colthart, Iain; McBride, Margot; Murray, Maria

    2010-01-01

    Purpose: The aim of this study was to evaluate the experiences of diagnostic and therapeutic radiographers as they mentored trainee assistant practitioners undertaking an educational programme. The evaluation study describes the challenges and benefits the radiographers experienced as mentors as well as giving their insights into the introduction of assistant practitioners in their departments. Method: The mentors' opinions were sought by a questionnaire which formed part of the evaluation of the respective diagnostic imaging and therapeutic educational programmes run by two colleges. Results: The response rate was 54% (22/41). Mentors described personal and professional benefits for themselves from undertaking this role. Although mentoring had provided a number of challenges including an increase in workload, the experience had also enhanced their teaching and mentoring skills and contributed to their Continuing Professional Development (CPD). Whilst the role was more time consuming than initially expected this had not impacted generally on their ability to undertake CPD or deliver patient care. In relation to the wider impact of the programmes some negative impact was reported on the speed of service delivery but not on the quality of practice. Mentors felt that the programmes had a positive effect on teamworking and had been beneficial for patient care. Some difficulties were noted in balancing the mentoring of trainee assistant practitioners and radiography undergraduates. Conclusion: The mentors strongly endorsed the educational programmes and their roles and responsibilities in their delivery. Protected time to carry out mentoring duties and establishing good communication with the colleges providing the theoretical teaching were identified as means of further improving the mentoring process.

  12. Stereoscopic radiographic images with gamma source encoding

    International Nuclear Information System (INIS)

    Strocovsky, S.G.; Otero, D

    2012-01-01

    Conventional radiography with X-ray tube has several drawbacks, as the compromise between the size of the focal spot and the fluence. The finite dimensions of the focal spot impose a limit to the spatial resolution. Gamma radiography uses gamma-ray sources which surpass in size, portability and simplicity to X-ray tubes. However, its low intrinsic fluence forces to use extended sources that also degrade the spatial resolution. In this work, we show the principles of a new radiographic technique that overcomes the limitations associated with the finite dimensions of X-ray sources, and that offers additional benefits to conventional techniques. The new technique called coding source imaging (CSI), is based on the use of extended sources, edge-encoding of radiation and differential detection. The mathematical principles and the method of images reconstruction with the new proposed technique are explained in the present work. Analytical calculations were made to determine the maximum spatial resolution and the variables on which it depends. The CSI technique was tested by means of Monte Carlo simulations with sets of spherical objects. We show that CSI has stereoscopic capabilities and it can resolve objects smaller than the source size. The CSI decoding algorithm reconstructs simultaneously four different projections from the same object, while conventional radiography produces only one projection per acquisition. Projections are located in separate image fields on the detector plane. Our results show it is possible to apply an extremely simple radiographic technique with extended sources, and get 3D information of the attenuation coefficient distribution for simple geometry objects in a single acquisition. The results are promising enough to evaluate the possibility of future research with more complex objects typical of medical diagnostic radiography and industrial gamma radiography (author)

  13. How patient positioning affects radiographic signs of canine lung disease

    International Nuclear Information System (INIS)

    Steyn, P.F.; Green, R.W.

    1990-01-01

    A single radiographic projection risks missing signs of lung disease. Four case reports of dogs are given to emphasize inadequate visualization with just one or two radiographs. It is advisable to take both right and left lateral views along with a dorsoventral view in a patient, that might have lung disease

  14. Radiographic demonstration of small intestinal villi on routine clinical studies

    International Nuclear Information System (INIS)

    Gelfand, D.W.; Ott, D.J.

    1981-01-01

    The radiographic demonstration of the small intestinal villi is reported. The villi were demonstrable with both single- and double-contrast methods on routine clinical studies. The primary requirement for their delineation appears to be employment of a high-resolution radiographic system. (orig.) [de

  15. Occupational stress among radiographers: the impact of sonagraphy ...

    African Journals Online (AJOL)

    Sonography responsibility on radiographers did not have any significant effect on psychosocial stress. A balance in the extended role could aid efficiency in service delivery while improving the social strength of the individual. Keywords: Occupational stress; radiographers; sonographers. Internet Journal of Medical Update ...

  16. Radiologist perceptions of radiographer role development in Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J. [School of Health Sciences, Robert Gordon University, Faculty of Health and Social Care, Garthdee Road, Garthdee, Aberdeen AB10 7QG (United Kingdom)]. E-mail: l.forsyth@rgu.ac.uk; Robertson, Elizabeth M. [Department of Radiology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZN (United Kingdom)]. E-mail: e.m.robertson@arh.grampian.scot.nhs.uk

    2007-02-15

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training.

  17. Comparative analysis of human and bovine teeth: radiographic density

    Directory of Open Access Journals (Sweden)

    Jefferson Luis Oshiro Tanaka

    2008-12-01

    Full Text Available Since bovine teeth have been used as substitutes for human teeth in in vitro dental studies, the aim of this study was to compare the radiographic density of bovine teeth with that of human teeth to evaluate their usability for radiographic studies. Thirty bovine and twenty human teeth were cut transversally in 1 millimeter-thick slices. The slices were X-rayed using a digital radiographic system and an intraoral X-ray machine at 65 kVp and 7 mA. The exposure time (0.08 s and the target-sensor distance (40 cm were standardized for all the radiographs. The radiographic densities of the enamel, coronal dentin and radicular dentin of each slice were obtained separately using the "histogram" tool of Adobe Photoshop 7.0 software. The mean radiographic densities of the enamel, coronal dentin and radicular dentin were calculated by the arithmetic mean of the slices of each tooth. One-way ANOVA demonstrated statistically significant differences for the densities of bovine and human enamel (p 0.05. Based on the results, the authors concluded that: a the radiographic density of bovine enamel is significantly higher than that of human enamel; b the radiodensity of bovine coronal dentin is statistically lower than the radiodensity of human coronal dentin; bovine radicular dentin is also less radiodense than human radicular dentin, although this difference was not statistically significant; c bovine teeth should be used with care in radiographic in vitro studies.

  18. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  19. Radiographic identification of the equine ventral conchal bulla.

    Science.gov (United States)

    Finnegan, C M; Townsend, N B; Barnett, T P; Barakzai, S Z

    Involvement of the ventral conchal sinus (VCS) is an important diagnostic and prognostic feature in cases of the equine sinus disease. The authors aimed to ascertain if the caudo-dorsal extension of the VCS, the ventral conchal bulla (VCB) is identifiable on plain radiographs of cadaver skulls without sinus disease. Bilateral frontonasal sinus flaps were made in 10 equine cadaver skulls. Plain lateral, lateral oblique and dorso-ventral radiographs were then obtained followed by the same views taken with stainless steel wire outlining the caudal border of the VCB. Plain radiographs were randomised and blindly evaluated by two observers who marked where they believed the VCB to be positioned. This was then correlated with the true position of the VCB using radiographs with wires in place. The ease of identification of the VCB was classified as 'easy' or 'difficult'. The VCB was correctly identified in 70 per cent of lateral radiographs, but only 45 per cent of lateral oblique radiographs and 17 per cent of dorso-ventral radiographs. If a clinician was confident that he or she could identify the VCB, they were usually correct. Conversely if the clinician judged VCB identification as 'difficult', they usually identified it incorrectly. In the authors' clinical experience, the VCB of horses with sinusitis involving this compartment is more radiologically evident than in clinically normal horses. Knowledge of the normal radiographic anatomy of this structure should aid clinicians in identifying horses with sinusitis affecting the VCS.

  20. Adult sail sign: radiographic and computed tomographic features.

    Science.gov (United States)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-02-01

    The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. To investigate the sail sign appearing in adult chest radiography. Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.

  1. Radiographic studies of developing calvaria at prenatal stages in ...

    African Journals Online (AJOL)

    Radiographic studies on the fetal heads of 32 one-humped camels (Camelus dromedarius) with 11 fetuses at the first trimester, 12 at the second trimester and 9 at the third trimester levels were conducted in Sokoto Metropolis. The study involved the radiographic evaluation of calvaria of different fetuses at first, second and ...

  2. The POEMS syndrome: Report of three cases with radiographic abnormalities

    International Nuclear Information System (INIS)

    Tanaka, O.; Ohsawa, T.

    1984-01-01

    Three cases of a unique multisystemic syndrome with polyneuropathy, organomegaly, endocrinopathy, M protein, and skin changes (the POEMS syndrome) are presented, along with a review of the literature. Clinical and radiographic features of this syndrome and etiological considerations are discussed. A variety of osteosclerotic lesions, nonspecific pleural effusion and ascites are characteristic radiographic manifestations. (orig.) [de

  3. Radiologist perceptions of radiographer role development in Scotland

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Robertson, Elizabeth M.

    2007-01-01

    Aim: To survey the perceptions of the Scottish radiology community in relation to radiographer role development. Methods: A postal questionnaire was sent to all consultant radiologists recorded on the NHS Scotland database of consultants. Results: Response rate was 63%. (i) Respondents considered increased professional standing of radiographers, best use of manpower resources, reduced pressure on the service and improved recruitment and retention, as positive advantages of radiographer development. (ii) The potential impact on radiology specialist registrar training, lack of clear medico-legal responsibilities and radiographers recognising the limitations of their abilities were identified as the main areas of radiologist anxiety. (iii) Fifty-seven percent did not consider current post-registration radiography education and training resources adequate to underpin the requirement of developed roles. (iv) Barriers to radiographer development were identified as lack of radiography and radiology staff, suitable education, financial constraints, traditional views and resistance to change. (v) Eighty-two percent reported support for radiographer role development and willingness to participate actively in developments. Conclusion: Despite reservations Scottish radiologists are supportive of the development of radiography colleagues, however, guidance is required on the medico-legal and accountability aspects of radiographers assuming new roles. Radiologist involvement in education and training for new roles may increase their confidence and trust in radiographers to work within the limitations of their competency and training

  4. Flash radiographic technique applied to fuel injector sprays

    International Nuclear Information System (INIS)

    Vantine, H.C.

    1977-01-01

    A flash radiographic technique, using 50 ns exposure times, was used to study the pattern and density distribution of a fuel injector spray. The experimental apparatus and method are described. An 85 kVp flash x-ray generator, designed and fabricated at the Lawrence Livermore Laboratory, is utilized. Radiographic images, recorded on standard x-ray films, are digitized and computer processed

  5. Clinical and Plain Radiograph Pattern of Joint Dislocations and ...

    African Journals Online (AJOL)

    Plain radiograph is an integral part of early assessment of patients' evaluation, though newer imaging modalities such as magnetic resonance imaging (MRI), ... Conclusion: The shoulder joint is the most frequently dislocated and a conventional plain radiograph is still valuable as a first line investigative modality in ...

  6. Evaluation of panoramic radiographs taken from 1056 Turkish children

    African Journals Online (AJOL)

    Objective: Panoramic radiographs (PRs) play an important role in the diagnosis and treatment planning of a wide range of dental and maxillofacial diseases and conditions. To examine and to determine the status of oral lesions, dental anomalies and pathologies in panoramic radiographs, which were taken at the ...

  7. Studies on the method of producing radiographic 170Tm source

    International Nuclear Information System (INIS)

    Maeda, Sho

    1976-08-01

    A method of producing radiographic 170 Tm source has been studied, including target preparation, neutron irradiation, handling of the irradiated target in the hot cell and source capsules. On the basis of the results, practical 170 Tm radiographic sources (29 -- 49Ci, with pellets 3mm in diameter and 3mm long) were produced in trial by neutron irradiation with the JMTR. (auth.)

  8. An exploratory study of radiographer's perceptions of radiographer commenting on musculo-skeletal trauma images in rural community based hospitals

    International Nuclear Information System (INIS)

    Howard, Morag L.

    2013-01-01

    Aim: This study sought to explore the perceptions of community hospital based radiographers in North East Scotland regarding the practice of radiographer commenting on musculo-skeletal trauma images. Method: A purposive sample of radiographers (n = 8) were recruited from community hospitals throughout the North-east of Scotland. A qualitative, exploratory study was conducted employing semi-structured interviews consisting of one focus group and two individual interviews. The interviews were audio recorded and transcribed in full to allow thematic analysis of the data using a framework adapted from Pope and Mays (2006). Main findings: This study revealed that the practice of radiographer commenting in the community provides a valuable front line opinion on musculo-skeletal trauma image appearances to enhance diagnostic outcomes for patients and streamline their care pathway. The appreciation shown from inter-professional colleagues for this practice induced feelings of professional pride and job satisfaction in the sample group. All participants expressed a desire to undertake additional training to allow progression from radiographer commenting to radiographer reporting of musculo-skeletal trauma images. Perceived barriers to the practice of radiographer commenting were time constraints and a lack of support with regards to continuing professional development (CPD) opportunities and mentorship from radiology colleagues. Conclusion: The practice of radiographer commenting in the community setting should be supported by ongoing training, and radiologist involvement in mentoring could provide radiographers with a valuable support mechanism. The voice of all radiographers regarding this extended role must be heard by professional leaders to ensure that the skills and education required for radiographer commenting are provided and subsequent patient care is not compromised

  9. Relation between size of contrast meter and radiographic density difference for radiographic test aluminium welds

    International Nuclear Information System (INIS)

    Senda, Tomio; Hirayama, Kazuo; Masaoka, Naotoshi; Fujita, Minoru.

    1977-01-01

    The influence of contrast meter with difference surface area (5.0 mm x 5.0 mm, 10.0 mm x 10.0 mm, 15.0 mm x 15.0 mm, 30.0 mm x 30.0 mm) and separated type on radiographic density difference (Δ D) were investigated for radiographic test of aluminum welds. It was found that the effect of scattered radiation on contrast meter represented highest at test specimen thickness of 20 mm, and Δ D was constant as the size was increased from 10.0 mm x 10.0 mm to 15.0 mm x 15.0 mm for aluminum contrast meter. For this reason, a proposal of the contrast meter with 10.0 mm x 10.0 mm (surface area) has made to replace (15.0 mm x 15 mm) at amendment of JIS Z 3105. (auth.)

  10. Methodology to evaluation of the density in radiographic image

    International Nuclear Information System (INIS)

    Louzada, M.J.Q.; Pela, C.A.; Belangero, W.D.; Santos-Pinto, R.

    1998-01-01

    This study was designed in order to optimize the optical densitometry technique in radiographic images by the setorization of the characteristic curves of the radiographic films. We used 24 radiographs of a stepped aluminium wedge that were taken without rigorous control development and manually revealed. The densitometric values of the steps images and its thickness, for each radiographic, was utilized to generate its particular mathematics expressions that represent its characteristic densitometric curves and then it were used for setorization. The densitometric values were obtained by a Macbeth TD528 densitometer. The study showed an optimization in the representation of the relationship between the optical density of the steps images of the wedge and its correspondent thickness, provided by the setorization, with mean square error around 10 -5 . This optimization will allow the use of this methodology in quantitative evaluations of bone mass, by radiographic images. (author)

  11. Radiographic heart-volume estimation in normal cats

    International Nuclear Information System (INIS)

    Ahlberg, N.E.; Hansson, K.; Svensson, L.; Iwarsson, K.

    1989-01-01

    Heart volume mensuration was evaluated on conventional radiographs from eight normal cats in different body positions using computed tomography (CT). Heart volumes were calculated from orthogonal thoracic radiographs in ventral and dorsal recumbency and from radiographs exposed with a vertical X-ray beam in dorsal and lateral recumbency using the formula for an ellipsoid body. Heart volumes were also estimated with CT in ventral, dorsal, right lateral and left lateral recumbency. No differences between heart volumes from CT in ventral recumbency and those from CT in right and left lateral recumbency were seen. In dorsal recumbency, however, significantly lower heart volumes were obtained. Heart volumes from CT in ventral recumbency were similar to those from radiographs in ventral and dorsal recumbency and dorsal/left lateral recumbency. Close correlation was also demonstrated between heart volumes from radiographs in dorsal/ left lateral recumbency and body weights of the eight cats

  12. Plain abdominal radiographs in acute medical emergencies: an abused investigation?

    Science.gov (United States)

    Feyler, S; Williamson, V; King, D

    2002-02-01

    Plain abdominal radiographs are commonly requested for acute medical emergencies on patients with non-specific abdominal symptoms and signs. In this study 131 plain abdominal radiographs performed on the day of admission were prospectively analysed. In only 16 cases (12%) the reasons for requests conformed to the recommended guidelines by the Royal College of Radiologists. The reason for the request was stated in the case notes in only three cases. In 62 cases (47%), there was no comment made on the film by the requesting clinician. There was a discrepancy in the interpretation of the radiograph between the clinician and the radiologist in 31 cases (24%). The clinical management was influenced by plain abdominal radiographs in only nine cases (7%). The majority of plain abdominal radiographs requested on acute medical emergencies is inappropriate. There is a need to ensure guidelines are followed to prevent unnecessary exposure of patients to radiation as well as preventing expenditure on irrelevant investigations.

  13. Is the owner entitled to radiographs taken of his animal?

    International Nuclear Information System (INIS)

    Hartung, K.

    1990-01-01

    In the Federal Republic of Germany a veterinarian owns radiographs taken of animals in his practice. They have to be filed like any other results of diagnostic procedures. This is important, because evidence is required in the case of a law suit. On the other hand, it has to be stressed that taking radiographs is the subject of a free contract between owner and veterinarian. So it is possible to take the radiographs solely with the purpose of giving them to the owner, who may have them analysed by any other veterinarian of his choice. This is especially true in hip radiographs, which are evaluated and filed by an adjudicator of the breed association. In any case the radiologist has the obligation to lend the radiographs to another veterinarian on request for inspection. The second veterinarian has to give them back as soon as possible

  14. Clinical and radiographic assessment of approximal carious lesions

    International Nuclear Information System (INIS)

    Espelid, I.; Tveit, A.B.

    1986-01-01

    The aim of the study was to compare the radiographic diagnosis of approximal carious lesions with visual observations of the approximal surfaces and within drilled Class II cavities (made into the pulp). Sound (n=28) and carious (n=123) approximal surfaces of extracted premolars and molars were radiographed. The radiographs were studied by seven observers to diagnose caries. Lesions without cavitation were most often classified as sound (61.3%). When lesions had cavities, the rate of detection increased to 89.1%. Sound surfaces were erroneously classified as carious in 15.7% of cases. Statistically, about 6 our of every 10 qualitative assessments of lesion depth on the basis of radiographs, correctly recorded lesions as being in enamel or extending into dentin. The interexaminer variation in radiographic caries diagnosis were mostly due to difference in diagnostic criteria, whereas differences in diagnostic capability were less important

  15. Conventional frontal radiographs compared with frontal radiographs obtained from cone beam computed tomography.

    Science.gov (United States)

    Nur, Metin; Kayipmaz, Saadettin; Bayram, Mehmet; Celikoglu, Mevlut; Kilkis, Dogan; Sezgin, Omer Said

    2012-07-01

    To test the hypothesis that there is no difference between measurements performed on conventional frontal radiographs (FRs) and those performed on FRs obtained from cone beam computed tomography (CBCT) scans. This study consisted of conventional FRs and CBCT-constructed FRs obtained from 30 young adult patients. Twenty-three landmarks were identified on both types of cephalometric radiographs. Twenty-one widely used cephalometric variables (14 linear distances, 4 angles, and 3 ratios) were calculated. Paired t-tests were performed to compare the means of corresponding measurements on two cephalometric radiographs of the same patient. Reproducibility of measurements ranged from 0.85 to 0.99 for CBCT-constructed FRs, and from 0.78 to 0.96 for conventional FRs. A statistically significant difference was observed between conventional FRs and CBCT-constructed FRs for all linear measurements (eurR-eurL, loR-loL, moR-moL, zygR-zygL, lapR-lapL, mxR-mxL, maR-maL, umR-umL, lmR-lmL, agR-agL, me-ans) (P .05). However, no statistically significant differences were noted between conventional FRs and CBCT-constructed FRs for ratios and angular measurements (P > .05). The hypothesis was rejected. A difference has been noted between measurements performed on conventional FRs and those performed on CBCT-constructed FRs, particularly in terms of linear measurements.

  16. Neonates do not need to be handled for radiographs

    International Nuclear Information System (INIS)

    Slade, Dawn; Alfaham, Mazin; Davis, Peter; Tuthill, David; Harrison, Sara; Morris, Susan; Guildea, Zoe

    2005-01-01

    The handling of sick neonates may have detrimental effects such as hypoxia or bradycardia. Such handling is inevitable due to the frequent need for practical procedures; however, minimising handling reduces these adverse events and may improve outcome. Radiography is one of the commonest procedures performed on neonates. Usually the infant is lifted and placed onto the radiographic cassette; however, modern incubators often incorporate a tray beneath the mattress in which the radiographic cassette can be placed without the need to disturb the infant. To compare the quality of chest radiographs taken using the standard direct contact method, with those taken using the under-tray technique. A series of chest radiographs taken over a 21-month period were analysed independently by two consultant paediatric radiologists unaware of the radiographic details. The position of the radiograph, i.e. direct contact or under-tray, was determined by the radiographer. Radiographic quality was scored on the following features: exposure, blurring, rotation, cut-off or coning, and side markers. A subjective score was also included. The results from each radiologist were analysed separately. Seventy chest radiographs were analysed - 25 standard method, 45 under-tray. A statistically significant advantage for the under-tray method was seen on two analyses - radiologist 1 for exposure, and radiologist 2 for cut-off. No other significant differences were noted. There were no differences in the infants' weights or radiation exposure. The under-tray method for taking radiographs may produce films of at least equivalent quality to the standard method. Since the standard method involves handling with potential desaturation and bradycardia, this technique should cease. (orig.)

  17. Advanced radiographic scanning, enhancement and electronic data storage

    International Nuclear Information System (INIS)

    Savoie, C.; Rivest, D.

    2003-01-01

    It is a well-known fact that radiographs deteriorate with time. Substantial cost is attributed to cataloguing and storage. To eliminate deterioration issues and save time retrieving radiographs, laser scanning techniques were developed in conjunction with viewing and enhancement software. This will allow radiographs to be successfully scanned and stored electronically for future reference. Todays radiographic laser scanners are capable Qf capturing images with an optical density of up to 4.1 at 256 grey levels and resolutions up to 4096 pixels per line. An industrial software interface was developed for the nondestructive testing industry so that, certain parameters such as scan resolution, number of scans, file format and location to be saved could be adjusted as needed. Once the radiographs have been scanned, the tiff images are stored, or retrieved into Radiance software (developed by Rivest Technologies Inc.), which will help to properly interpret the radiographs. Radiance was developed to allow the user to quickly view the radiographs correctness or enhance its defects for comparison and future evaluation. Radiance also allows the user to zoom, measure and annotate areas of interest. Physical cost associated with cataloguing, storing and retrieving radiographs can be eliminated. You can now successfully retrieve and view your radiographs from CD media or dedicated hard drive at will. For continuous searches and/or field access, dedicated hard drives controlled by a server would be the media of choice. All scanned radiographs will be archived to CD media (CD-R). Laser scanning with a proper acquisition interface and easy to use viewing software will permit a qualified user to identify areas of interest and share this information with his/her colleagues via e-mail or web data access. (author)

  18. A radiographic study of solitary bone cysts

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Rak; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral and Maxillofacial Radiology, Division of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1994-02-15

    The aim of this study was to evaluate the clinical, radiographic and histopathologic features of 23 cases of solitary bone cyst by means of the analysis of radiographs and biopsy specimens in 23 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chunbuk National University. The obtained results were as follows; 1. The incidence of solitary bone cyst was almost equal in males (52.2%) and in females(42.8%) and the prevalent age of the solitary bone cyst were the second decade (47.8%) and the third decade (21.7%). 2. In the signs and symptoms of solitary bone cyst, pain or tenderness revealed in 17.4%, swelling revealed in 13.0%, pain and swelling revealed in 21.7%, paresthesia revealed in 4.4% and 43.5% were a symptom and the tooth vitality involved in the solitary bone cyst, 76.5% were posterior and 23.5% were either positive or negative. 3. In the location of the solitary bone cyst, 47.8% present posterior region, 21.7% present anterior region, 21.6% present anterior and posterior region, 4.4% present condylar process area. 4. In the hyperostotic border of the solitary bone cyst, 47.8% were seen entirely, 21.8% were seen partially, and 30.4% were not seen. 5. In the change of tooth, 59.1% were loss of the alveolar lamina dura, 13.6% were root resorption 4.55% were tooth displacement, 4.55% were root resorption and tooth displacement. 6. In the change of cortical bone of the solitary bone cyst, 39.1% were intact and 60.9% were thinning and expansion of cortical bone. 7. In the histopathologic findings of 9 cases, 33.3% were thin connective tissue wall, 11.1% were thickened myxo-fibromatous wall, 55.6% were thickened myxofibromatous wall with dysplastic bone formation.

  19. A radiographic study of solitary bone cysts

    International Nuclear Information System (INIS)

    Kim, Kyung Rak; Hwang, Eui Hwan; Lee, Sang Rae

    1994-01-01

    The aim of this study was to evaluate the clinical, radiographic and histopathologic features of 23 cases of solitary bone cyst by means of the analysis of radiographs and biopsy specimens in 23 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chunbuk National University. The obtained results were as follows; 1. The incidence of solitary bone cyst was almost equal in males (52.2%) and in females(42.8%) and the prevalent age of the solitary bone cyst were the second decade (47.8%) and the third decade (21.7%). 2. In the signs and symptoms of solitary bone cyst, pain or tenderness revealed in 17.4%, swelling revealed in 13.0%, pain and swelling revealed in 21.7%, paresthesia revealed in 4.4% and 43.5% were a symptom and the tooth vitality involved in the solitary bone cyst, 76.5% were posterior and 23.5% were either positive or negative. 3. In the location of the solitary bone cyst, 47.8% present posterior region, 21.7% present anterior region, 21.6% present anterior and posterior region, 4.4% present condylar process area. 4. In the hyperostotic border of the solitary bone cyst, 47.8% were seen entirely, 21.8% were seen partially, and 30.4% were not seen. 5. In the change of tooth, 59.1% were loss of the alveolar lamina dura, 13.6% were root resorption 4.55% were tooth displacement, 4.55% were root resorption and tooth displacement. 6. In the change of cortical bone of the solitary bone cyst, 39.1% were intact and 60.9% were thinning and expansion of cortical bone. 7. In the histopathologic findings of 9 cases, 33.3% were thin connective tissue wall, 11.1% were thickened myxo-fibromatous wall, 55.6% were thickened myxofibromatous wall with dysplastic bone formation.

  20. Digitization of radiographic inspection for pipeline girth welded joints

    International Nuclear Information System (INIS)

    Uemura, Shimpei

    2016-01-01

    In radiographic inspection for the girth welded joints of natural gas pipeline, film radiographic testing (FRT) is applied presently in Japan. However, as of July 2016, the work of establishing JIS standard for radiographic inspection with digital detector is in progress. In order to provide users with the merit of digitization as soon as possible, the authors have developed NSDART (Nittetsu-Sumikin digital detector array technology) as a field X-ray inspection system for the girth welded joints of pipeline. This paper reports the required performances discussed in face of development of NSDART, selection of digital detector, and outline of NSDART, and shows part of the radiographic images acquired with NSDART. As required performances, the following were established: (1) required image quality for radiographic image, (2) identifiable minimum wire diameter of transmission meter, (3) density range of radiographic image and value of gradation meter, (4) spatial resolution via Duplex Wire, (5) X-ray generator, (6) real time performance, and (7) display for observing radiographic image. As for the selection of digital detector, flat panel detector was judged to be the most suitable, and its incorporation to NSDART was determined. NSDART devices are composed of a magnet-wheeled self-propelled imaging device, personal computer, controller, and externally installed display for judgment. (A.O.)

  1. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  2. Relationship between stress ankle radiographs and injured ligaments on MRI

    International Nuclear Information System (INIS)

    Lee, Kyoung Min; Chung, Chin Youb; Chung, Myung Ki; Won, Sung Hun; Lee, Seung Yeol; Park, Moon Seok; Kwon, Soon-Sun

    2013-01-01

    This study was performed to investigate the relationship between the injured lateral ankle ligaments on MRI and stress ankle radiographs. Two hundred and twenty-nine consecutive patients (mean age 35.5 years, SD 14.6 years; 136 males and 93 females) that underwent ankle stress radiographs and MRI for lateral ankle instability were included. Tibiotalar tilt angle and anterior translation of talus were measured on stress ankle radiographs. Degree of lateral ligaments (anterior talofibular, calcaneofibular, and posterior talofibular) and deltoid ligament injuries were evaluated and scored as intact (0), partial injury (1), and complete injury (2) on MR images. Effusion of ankle joint was also recorded. The effects of gender, age, injuries of ligaments, and ankle joint effusion on stress radiographs were statistically analyzed. Gender (p = 0.010), age (p = 0.020), and anterior talofibular ligament (ATFL) injury (p < 0.001) were the factors significantly affecting tibiotalar tilt angle. Posterior talofibular ligament (PTFL) injury (p = 0.014) was found to be the only significant factor affecting the anterior translation on the anterior drawer radiographs. ATFL injury and PTFL injury on MRI significantly affected tibiotalar tilt angle and anterior drawer on stress radiographs. Other factors, such as age and gender, need to be considered in evaluating radiographic lateral ankle instability. (orig.)

  3. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  4. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  5. Chest radiographic features of human metapneumovirus infection in pediatric patients

    International Nuclear Information System (INIS)

    Hilmes, Melissa A.; Daniel Dunnavant, F.; Singh, Sudha P.; Ellis, Wendy D.; Payne, Daniel C.; Zhu, Yuwei; Griffin, Marie R.; Edwards, Kathryn M.; Williams, John V.

    2017-01-01

    Human metapneumovirus (HMPV) was identified in 2001 and is a common cause of acute respiratory illness in young children. The radiologic characteristics of laboratory-confirmed HMPV acute respiratory illness in young children have not been systematically assessed. We systematically evaluated the radiographic characteristics of acute respiratory illness associated with HMPV in a prospective cohort of pediatric patients. We included chest radiographs from children <5 years old with acute respiratory illness who were enrolled in the prospective New Vaccine Surveillance Network (NVSN) study from 2003 to 2009 and were diagnosed with HMPV by reverse transcription-polymerase chain reaction (RT-PCR). Of 215 HMPV-positive subjects enrolled at our tertiary care children's hospital, 68 had chest radiographs obtained by the treating clinician that were available for review. Two fellowship-trained pediatric radiologists, independently and then in consensus, retrospectively evaluated these chest radiographs for their radiographic features. Parahilar opacities were the most commonly observed abnormality, occurring in 87% of children with HMPV. Hyperinflation also occurred frequently (69%). Atelectasis (40%) and consolidation (18%) appeared less frequently. Pleural effusion and pneumothorax were not seen on any radiographs. The clinical presentations of HMPV include bronchiolitis, croup and pneumonia. Dominant chest radiographic abnormalities include parahilar opacities and hyperinflation, with occasional consolidation. Recognition of the imaging patterns seen with common viral illnesses like respiratory syncytial virus (RSV) and HMPV might facilitate diagnosis and limit unnecessary antibiotic treatment. (orig.)

  6. Image quality preferences among radiographers and radiologists. A conjoint analysis

    International Nuclear Information System (INIS)

    Ween, Borgny; Kristoffersen, Doris Tove; Hamilton, Glenys A.; Olsen, Dag Rune

    2005-01-01

    Purpose: The aim of this study was to investigate the image quality preferences among radiographers and radiologists. The radiographers' preferences are mainly related to technical parameters, whereas radiologists assess image quality based on diagnostic value. Methods: A conjoint analysis was undertaken to survey image quality preferences; the study included 37 respondents: 19 radiographers and 18 radiologists. Digital urograms were post-processed into 8 images with different properties of image quality for 3 different patients. The respondents were asked to rank the images according to their personally perceived subjective image quality. Results: Nearly half of the radiographers and radiologists were consistent in their ranking of the image characterised as 'very best image quality'. The analysis showed, moreover, that chosen filtration level and image intensity were responsible for 72% and 28% of the preferences, respectively. The corresponding figures for each of the two professions were 76% and 24% for the radiographers, and 68% and 32% for the radiologists. In addition, there were larger variations in image preferences among the radiologists, as compared to the radiographers. Conclusions: Radiographers revealed a more consistent preference than the radiologists with respect to image quality. There is a potential for image quality improvement by developing sets of image property criteria

  7. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  8. Chest radiographic features of human metapneumovirus infection in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Hilmes, Melissa A.; Daniel Dunnavant, F.; Singh, Sudha P.; Ellis, Wendy D. [Vanderbilt University School of Medicine, Department of Radiology, Nashville, TN (United States); Payne, Daniel C. [Centers for Disease Control and Prevention, Atlanta, GA (United States); Zhu, Yuwei [Vanderbilt University School of Medicine, Department of Biostatistics, Nashville, TN (United States); Griffin, Marie R. [Vanderbilt University School of Medicine, Department of Health Policy, Nashville, TN (United States); Edwards, Kathryn M. [Vanderbilt University School of Medicine, Department of Pediatrics, Nashville, TN (United States); Williams, John V. [University of Pittsburgh School of Medicine, Department of Pediatrics, Pittsburgh, PA (United States); University of Pittsburgh of UPMC, Children' s Hospital of Pittsburgh, Pittsburgh, PA (United States)

    2017-12-15

    Human metapneumovirus (HMPV) was identified in 2001 and is a common cause of acute respiratory illness in young children. The radiologic characteristics of laboratory-confirmed HMPV acute respiratory illness in young children have not been systematically assessed. We systematically evaluated the radiographic characteristics of acute respiratory illness associated with HMPV in a prospective cohort of pediatric patients. We included chest radiographs from children <5 years old with acute respiratory illness who were enrolled in the prospective New Vaccine Surveillance Network (NVSN) study from 2003 to 2009 and were diagnosed with HMPV by reverse transcription-polymerase chain reaction (RT-PCR). Of 215 HMPV-positive subjects enrolled at our tertiary care children's hospital, 68 had chest radiographs obtained by the treating clinician that were available for review. Two fellowship-trained pediatric radiologists, independently and then in consensus, retrospectively evaluated these chest radiographs for their radiographic features. Parahilar opacities were the most commonly observed abnormality, occurring in 87% of children with HMPV. Hyperinflation also occurred frequently (69%). Atelectasis (40%) and consolidation (18%) appeared less frequently. Pleural effusion and pneumothorax were not seen on any radiographs. The clinical presentations of HMPV include bronchiolitis, croup and pneumonia. Dominant chest radiographic abnormalities include parahilar opacities and hyperinflation, with occasional consolidation. Recognition of the imaging patterns seen with common viral illnesses like respiratory syncytial virus (RSV) and HMPV might facilitate diagnosis and limit unnecessary antibiotic treatment. (orig.)

  9. Do general radiographic examinations resemble a person-centred environment?

    International Nuclear Information System (INIS)

    Hayre, C.M.; Blackman, S.; Eyden, A.

    2016-01-01

    Aim and objective: It is argued whether general radiographic examinations adhere to a person-centred approach within the direct digital radiography (DDR) environment. General radiographic examinations continue to increase and constitute approximately 90% of all examinations undertaken in the clinical environment. This study explored the potential impact patients experience whilst undergoing general imaging examinations. Method: An ethnographic methodology provided insight of two general radiography environments in the United Kingdom (UK) using participant observation and semi-structured interviews. Findings: The findings highlighted an ‘in and out’ culture whereby patients are ‘hurried’ and ‘rushed’ out of X-ray rooms in response to increasing time pressures experienced by diagnostic radiographers. In addition, this study challenged that patients may begin to rank ‘speed’ and ‘waiting times’ above other elements of radiographic care thus presenting new challenges for radiographers within the clinical environment. Conclusion: It is asserted that radiographers should remain holistic healthcare professionals and not begin to resemble operators on the production line. Further, it challenges whether patients are beginning to rank aspects of radiographic care within contemporary practices. Advances in knowledge: Few studies have explored the radiographer–patient relationship within the DDR environment, yet this study provides insight of person-centred practices within contemporary practices. - Highlights: • Challenges whether the use of DDR conforms to a person-centred approach. • Challenges whether radiographers are ‘treating patients as persons’ using DDR. • Patients may begin to rank ‘speed’ and ‘waiting times’ above other aspects of radiographic care.

  10. Standardization of thorax, skull and pelvis radiographic images

    International Nuclear Information System (INIS)

    Pina, D.R.; Ghilardi Netto, T.; Trad, C.S.; Brochi, M.A. Corte; Duarte, S.B.; Pina, S.R.

    2001-01-01

    The radiographic techniques for production of chest, skull and pelvis exam were determined for the standard patient. These techniques produced the quality image with smaller dose, for a standard patient, at any conventional X-ray equipment. The radiographic contrast produced for these techniques was measured utilizing the realistic-analytic phantom and classified as an ideal radiographic contrast. This work has the aim to keep the standard of the quality image, for any thickness of patients usually found in clinic routine of the radiodiagnosis service, satisfying the relation risk-benefit for the patient and cost- benefit for the institution. (author)

  11. The concept of advanced radiographic practice: An international perspective

    International Nuclear Information System (INIS)

    Hardy, Maryann; Legg, Jeffrey; Smith, Tony; Ween, Borgny; Williams, Imelda; Motto, Jenny

    2008-01-01

    Advanced radiographic practice has been the focus of much discussion and debate over the last decade, not only in the United Kingdom where advanced practitioner roles are now recognised within the national career framework, but also internationally. Yet, despite almost simultaneous professional movement towards advanced radiographic practice philosophy and ideals in many countries, international collaboration on this development has been minimal. This paper marks a growing international dialogue in this field. It discusses the theoretical concepts of advanced radiographic practice and the development of advanced practitioner roles, incorporating evidence and ideas from differing international perspectives and debates progress towards a potential unified global advanced practice identity

  12. Main factors of efficiency of automated radiographic complex

    International Nuclear Information System (INIS)

    Akopov, V.S.; Voronin, S.A.; Grachev, A.V.; Golenishchev, I.A.; Majorov, A.N.; Meshalkin, I.A.

    1978-01-01

    The amount of work providing an assessment of the efficiency of a complex for automatized radiographic control is considered. The technique involves four stages. An analysis was performed to ascertain the efficiency of control of flaw detectability with regard to each of the stages of radiographic control. The relationships used in determining control efficiency and cited in the paper serve as a foundation for optimizing the technical parameters of the devices of the automatized complex and for creating calculation methods for generalized assessments of the efficiency of radiographic control

  13. Radiological diagnosis of chest wall tuberculosis: CT versus chest radiograph

    International Nuclear Information System (INIS)

    Liu Fugeng; Pan Jishu; Chen Qihang; Zhou Cheng; Yu Jingying; Tang Dairong

    2006-01-01

    Objective: To evaluate the role of CT or Chest radiograph in diagnosis of chest wall tuberculosis. Methods: The study population included 21 patients with chest wall tuberculosis confirmed by operation or biopsy. Chest radiograph and plain CT were performed in all eases, while enhanced CT in 9 cases, and all images were reviewed by 2 radiologists. Results: Single soft tissue mass of the chest wall was detected in all cases on CT, but not on chest radiograph(χ 2 =42.000, P 2 =4.421, P<0.05). Conclusion: CT, especially enhanced CT scan is the first choice in the diagnosis of chest wall tuberculosis. (authors)

  14. Radiographic imaging of otitis media and interna in pigs

    International Nuclear Information System (INIS)

    Harlizius, J.; Kluczniok, C.; Bollwahn, W.

    1997-01-01

    Middle and inner ear infections have been reported as a clinical entity in swine, other animal species and humans. In pigs, the anatomical-pathological and microbiological findings have been described. In this report, we describe radiographic findings in affected pigs. A total of 25 pigs with a head tilt and circling, as clinical signs of otitis media and interna, were examined. The majority were weaner-pigs with dyspnea or rhinitis. In radiographs, there was an increased opacity of the bulla tympanica, often accompanied by marginal destruction or thickening of the bulla wall. The radiographic findings confirmed the clinical diagnosis in each affected pig, but there were 5 false positive interpretations

  15. Skeletal changes mimicking intrathoracic disease on chest radiographs

    International Nuclear Information System (INIS)

    Gelderen, WFC van

    2009-01-01

    Full text: Various chest radiographs are illustrated to demonstrate features where bony changes may mimic intrathoracic disease. To confirm the skeletal origin and nature, further conventional radiographs often suffice, and the need for CT or scintigraphy may therefore be obviated. At the time of presentation for radiography of the chest, further pertinent clinical details can be obtained from the patient by the department staff, as required. All previous radiographs and radiological reports should be readily available. In order to add to the educational value of the 13 cases illustrated, all are presented in quiz format, with the answers and further images included in the text.

  16. Radiographic differentiation of atypical tuberculosis from mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Tarver, R.D.; Pearcy, E.A.; Conces, D.J. Jr.; Mathur, P.N.

    1987-01-01

    The chest radiographs of 95 patients with the new diagnosis of atypical turberculosis were reviewed to determine if any significant differences between atypical tuberculosis and that caused by Mycobacterium tuberculosis could be discerned. Findings included upper lobe involvement in B4 of the 95 patients and cavities in 76, with nearly equal groups having no, moderate, or extensive surrounding alveolar disease. Nodules were common; in six patients a nodule was the sole manifestation of disease. Adenopathy was seen in 12 of the 95 patients, atlectasis in 45, pleural thickening in 90, and effusions in three. These radiographic findings did not allow the radiographic differentiation of atypical tuberculosis from Mycobacterium tuberculosis infection

  17. Comparison of radiographic and radionuclide skeletal surveys in battered children

    International Nuclear Information System (INIS)

    Pickett, W.J.; Faleski, E.J.; Chacko, A.; Jarrett, R.V.

    1983-01-01

    A review of 13 cases of suspected child abuse in which radionuclide (RN) scans, radiographic skeletal surveys, and sufficient follow-up were available showed that the RN scans were insensitive, even though fractures were more than 48 hours old at the time of the scan. Frequently missed lesions included skull and extremity fractures. Furthermore, soft tissue and visceral abnormalities that were identified on radiographic examination went undetected on RN scan. We conclude that, although the RN scan may augment the radiographic examination, it should not be used alone to screen for the battered child

  18. Radiographic studies on the development of cheek teeth in donkeys

    International Nuclear Information System (INIS)

    Misk, N.A.; Seilem, S.M.

    1997-01-01

    The current study was carried out on 60 head specimens of donkeys in addition to five living animals. Specimens and animal's heads were radiographed. Radiographs were grouped from 1 day up to 15 years of age. Recorded data included the following points: 1) Time of radiographic appearance and different developmental stages of deciduous and permanent cheek teeth. 2) Length of deciduous cheek teeth from birth to shedding. 3) Length of permanent cheek teeth from birth to senility. 4) Body and root length from age 5 up to 15 years of age. 5) Wolf teeth: occurrence, time of eruption and shedding. All results were documented and illustrated in tables and photographs

  19. Retrospective assessment of thoracic radiographic findings in metastatic canine hemangiosarcoma

    International Nuclear Information System (INIS)

    Hammer, A.S.; Bailey, M.Q.; Sagartz, J.E.

    1994-01-01

    Twenty-one dogs with histopathologically confirmed hemangiosarcoma were evaluated by thoracic radiography for metastatic disease. All dogs had histopathologic examinations of the lungs within two weeks of thoracic radiography. Fourteen dogs had histopathologic evidence of pulmonary hemangiosarcoma; metastatic disease was detected radiographically in eleven of these dogs. The most common radiographic pattern was that of poorly defined small coalescing nodules (8 dogs); other radiographic patterns included well-circumscribed nodules (3 dogs) and alveolar infiltrates secondary to hemorrhage (2 dogs). Differential diagnoses for diffuse, poorly defined, coalescing pulmonary opacities should include hemangiosarcoma in addition to edema, lymphoma, systemic mycoses, fibrosis, allergy, toxicosis, and carcinomas

  20. Neutron radiographic techniques, facilities and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    This is a collection of three papers, written for presentation on two international conferences. The first paper: ''Neutron radiography. Techniques and facilities'', written by J.P. Barton of N-Ray Engineering Co. La Jolla, CA., USA and J.C. Domanus was presented at the International Symposium on the Use and Development of Low and Medium Flux Research Reactors at the Massachusets Institute of Technology, Cambridge, Mass., USA, 16-19 October 1983. The second paper: ''Neutron radiography with the DR-1 reactor at Risoe National Laboratory'', written by J.C. Domanus, was presented at the same Symposium. The third paper: ''Defects in nuclear fuel revealed by neutron radiography'', written by J.C. Domanus is accepted for presentation on 18 October 1984 to the 3rd European Conference on Nondestructive Testing, Florence, Italy, 15-18 October 1984. While the first paper describes the principles of neutron radiographic techniques and facilities, the second one describes an example of such facility and the third gives an example of application of neutron radiography in the field of nuclear fuel. (author)

  1. Cold neutron radiographic apparatus and method

    International Nuclear Information System (INIS)

    Larsen, J.E.

    1980-01-01

    Cold neutron radiography may be improved by matching neutron temperature to the specific material to be analyzed. It is possible to bombard the material with neutrons having the precise average temperature necessary to realize the minimum attenuation coefficient, or to choose a neutron temperature that would increase the attenuation by inclusions, defects, etc., or to choose a neutron temperature that provides a good balance between sample transmission and defect attenuation. Other neutron temperatures might also be chosen for other reasons. This may be done by having a source of neutrons embedded in a moderator material, such as solid methane, and cooling the moderator material to the desired temperature by a cryogenic refrigerator. In another embodiment, neutrons from a nuclear reactor are passed through a moderator cooled by a cryogenic refrigerator. Since the neutron temperature is matched to the material being radiographically inspected, improved contrast and resolution can be obtained through thicker materials than it has heretofore been possible to analyze by cold neutron radiography. More optimum filtering of a neutron beam is also achieved by using a cryogenic refrigerator to cool the neutron beam filter. (auth)

  2. Advanced radiographic practice - the legal aspects

    International Nuclear Information System (INIS)

    Alderson, C.J.; Hogg, P.

    2003-01-01

    Allied health and nursing professionals are continuing to expand their responsibilities into clinical areas outside their traditional spheres of interest; typically, many of these new responsibilities are found within the medical (doctor) domain. Such responsibilities are often at an advanced clinical level and consequently higher demands are placed upon the professionals, not least in terms of clinical updating, competence to practice and also legal liability. This article explores the legal implications of practising at an advanced clinical level with particular reference to legal claims. The first part of the article commences with an outline of pertinent law in England and Wales. The latter part of the article explores actual cases from which allied health professionals (eg radiographers) can gain valuable information. Throughout the article suggestions for good practice are indicated. Examples of good practice include: the need to base your practice on evidence and peer practice; the need to keep detailed records (protocols) of such practice; the need to know when you are at the limit of your ability; and as such when to ask for advice from a medical practitioner/radiologist

  3. Non-radiographic methods for IGRT

    International Nuclear Information System (INIS)

    Semwal, Manoj K.

    2016-01-01

    The primary goal of radiation therapy is to deliver a tumouricidal dose within a defined target volume while minimizing dose to surrounding normal tissues. In recent years, advanced technologies such as intensity modulated radiotherapy (IMRT), stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT) have been used to meet the goal. High dose conformity and steep dose gradients beyond the target volume achieved with these technologies warrant high level of accuracy in the dose delivery. Therefore, accurate patient localization, target segmentation and motion compensation have become mandatory requirements. Several technologies have been developed over the years to image the patient for treatment planning and for subsequent daily imaging/tracking while the patient is on the treatment table. For image guided radiotherapy (IGRT) some of the technologies are kilovoltage (kV) x-rays imaging, in-room computed tomography (CT), kV and MV cone-beam CT(CBCT). One of the chief drawbacks of these technologies is addition of radiation dose to the patients. There are other technologies that do not use ionizing radiation such as USG, MRI, patient surface monitoring using infrared and optical radiation, and radiofrequency (RF)-based localization/tracking systems that are also being developed for the purpose. These technologies may be collectively called as non-radiographic (NR) technologies for IGRT

  4. Radiographic features of Golden Retriever muscular dystrophy.

    Science.gov (United States)

    Brumitt, Jason W; Essman, Stephanie C; Kornegay, Joe N; Graham, John P; Weber, William J; Berry, Clifford R

    2006-01-01

    Golden Retriever muscular dystrophy is an inherited, degenerative myopathy due to the absence of dystrophin and is used as a model of Duchenne muscular dystrophy of young boys. This report describes the radiographic abnormalities of Golden Retriever muscular dystrophy in 26 dogs. The thoracic abnormalities included diaphragmatic asymmetry (18/26), diaphragmatic undulation (18/26), and gastro-esophageal hiatal hernia (6/26). Pelvic abnormalities included narrowing of the body of the ilia (14/19), ventral deviation and curvature of the tuber ischii (14/19), elongation of the obturator foramen with a decrease in opacity of the surrounding bone (12/19), and lateral flaring of the wings of the ilia (12/19). Abdominal abnormalities consisted of hepatomegaly (14/22) and poor serosal detail (12/22). The unique thoracic abnormalities were a consistent finding in affected Golden Retriever muscular dystrophy dogs. The diagnosis of muscular dystrophy should be included in the differential list if the combination of diaphragm undulation and asymmetry, and gastro-esophageal hiatal hernia are identified. These diaphragmatic abnormalities are related to hypertrophy and hyperplasia of the diaphragm. Additionally, the skeletal changes of pelvic tilt, elongation of the pelvis, widening of the obturator foramina and thinning of the ischiatic tables appear to be specific to Golden Retriever muscular dystrophy in dogs. These pelvic abnormalities are most likely secondary to bone remodeling associated with the progressive skeletal myopathy and subsequent contracture/fibrosis.

  5. Radiographic identification of ingested disc batteries

    International Nuclear Information System (INIS)

    Maves, M.D.

    1986-01-01

    Recently, the hazards by posed the accidental ingestion and impaction of small disc batteries have been widely publicized in the medical and lay press. These foreign bodies, when lodged in the esophagus, leak a caustic solution of 26 to 45% sodium or potassium hydroxide which can cause a burn injury to the esophagus in a very short period of time. Because of the considerable clinical morbidity and mortality from this foreign body, it becomes imperative for the radiologist to quickly and accurately identify disc batteries on plain radiographs. This communication offers a series of radiologic signs important in the identification of disc batteries demonstrate a double density shadow due to the bilaminar structure of the battery. On lateral view, the edges of most disc batteries are round and again present a step-off at the junction of the cathode and anode. These findings are differentiated from the more common esophageal foreign body of a coin which does not have a double density on frontal projection, has a much sharper edge and no visible stepoff. (orig.)

  6. Lung involvement quantification in chest radiographs

    International Nuclear Information System (INIS)

    Giacomini, Guilherme; Alvarez, Matheus; Oliveira, Marcela de; Miranda, Jose Ricardo A.; Pina, Diana R.; Pereira, Paulo C.M.; Ribeiro, Sergio M.

    2014-01-01

    Tuberculosis (TB) caused by Mycobacterium tuberculosis, is an infectious disease which remains a global health problem. The chest radiography is the commonly method employed to assess the TB's evolution. The methods for quantification of abnormalities of chest are usually performed on CT scans (CT). This quantification is important to assess the TB evolution and treatment and comparing different treatments. However, precise quantification is not feasible for the amount of CT scans required. The purpose of this work is to develop a methodology for quantification of lung damage caused by TB through chest radiographs. It was developed an algorithm for computational processing of exams in Matlab, which creates a lungs' 3D representation, with compromised dilated regions inside. The quantification of lung lesions was also made for the same patients through CT scans. The measurements from the two methods were compared and resulting in strong correlation. Applying statistical Bland and Altman, all samples were within the limits of agreement, with a confidence interval of 95%. The results showed an average variation of around 13% between the two quantification methods. The results suggest the effectiveness and applicability of the method developed, providing better risk-benefit to the patient and cost-benefit ratio for the institution. (author)

  7. Radiographic analysis of shoulder anatomical arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Merolla, Giovanni [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)], E-mail: gmerolla@shouldertech.it; Di Pietto, Francesco; Romano, Stefania [Department of Diagnostic Imaging, ' A. Cardarelli' Hospital, Naples (Italy); Paladini, Paolo; Campi, Fabrizio; Porcellini, Giuseppe [Unit of Shoulder and Elbow Surgery, ' D. Cervesi' Hospital, L. Van Beethoven 46 Street, 47841 Cattolica (Italy)

    2008-10-15

    Arthroplasty is the standard treatment for advanced shoulder osteoarthritis. Modern prostheses designs have modular features whose size, shaft/head and body morphology can be adjusted. Total Shoulder Arthroplasty (TSA) provides better results. A complete X-ray follow-up is essential to assess the results and evaluate the survival rates of a shoulder prosthesis. Antero-posterior at 40 deg. in both internal and external rotation (true AP view) and axillary view are recommended to assess the following parameters: orientation and translation of the humeral component, offset, size and height of the humeral head, acromio-humeral distance, distribution and fixation of the cement, stress shielding and cortical resorption, radiolucent lines, subsidence and tilt, glenoid wear and 'bone stock', prostheses instability, glenoid component shift. Shoulder hemiarthroplasty can lead to glenoid wear; the true AP film at 40 deg. of internal rotation provides the best profile of gleno-humeral joint to depict glenoid erosion. Shift of the glenoid component in TSA is identified as tilting or medial migration on true AP and axillary views in the early postoperative period (1-2 months) and at minimum of 2 years. An exhaustive radiographic analysis remains essential to monitor the prosthetic implant and detect early and late complications or risk factors of prosthetic loosening.

  8. MINAC, A new radiographic inspection capability

    International Nuclear Information System (INIS)

    Lapides, M.E.; Schonberg, R.

    1983-01-01

    In service, radiographic inspection of thick section, metallic components has historically been limited to the capabilities of radioisotopic sources such as cobalt and iridium. Although practical in many applications, these sources tend to be restricted by output intensity, by resolution obtainable, and by the physical size and weight of necessary transport shielding. In nuclear plant applications, any radiography is also frequently inhibited by the presence of a radiation background from activated corrosion products on the inspection object which may fog the film before the desired exposure is achieved. In recognition of these limitations and the need for improved capability in the conduct of mandated ten-year inspection of U.S. nuclear plant components such as reactor coolant pumps, pressure vessel nozzles and valve bodies, the Electric Power Research Institute (EPRI) undertook the development of a high energy, X-ray device appropriate for in service inspection of thick section (up to approximately 30 cm of steel) components. The development was conducted by Schonberg Radiation (U.S.A). The product, MINAC, a miniaturized linear accelerator system, has been in use in many plant inspections since April 1981. This paper describes the development and typical applications of MINAC

  9. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Suojaervi, Nora; Lindfors, N. [Helsinki University Central Hospital, Department of Hand Surgery, Helsinki (Finland); Sillat, T.; Koskinen, S.K. [HUS Helsinki Medical Imaging Center, Helsinki University Central Hospital, Department of Radiology, Helsinki (Finland)

    2015-12-15

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities. (orig.)

  10. Radiographical measurements for distal intra-articular fractures of the radius using plain radiographs and cone beam computed tomography images.

    Science.gov (United States)

    Suojärvi, Nora; Sillat, T; Lindfors, N; Koskinen, S K

    2015-12-01

    Operative treatment of an intra-articular distal radius fracture is one of the most common procedures in orthopedic and hand surgery. The intra- and interobserver agreement of common radiographical measurements of these fractures using cone beam computed tomography (CBCT) and plain radiographs were evaluated. Thirty-seven patients undergoing open reduction and volar fixation for a distal radius fracture were studied. Two radiologists analyzed the preoperative radiographs and CBCT images. Agreement of the measurements was subjected to intra-class correlation coefficient and the Bland-Altman analyses. Plain radiographs provided a slightly poorer level of agreement. For fracture diastasis, excellent intraobserver agreement was achieved for radiographs and good or excellent agreement for CBCT, compared to poor interobserver agreement (ICC 0.334) for radiographs and good interobserver agreement (ICC 0.621) for CBCT images. The Bland-Altman analyses indicated a small mean difference between the measurements but rather large variation using both imaging methods, especially in angular measurements. For most of the measurements, radiographs do well, and may be used in clinical practice. Two different measurements by the same reader or by two different readers can lead to different decisions, and therefore a standardization of the measurements is imperative. More detailed analysis of articular surface needs cross-sectional imaging modalities.

  11. Radiographic assessment of venous catheter position in children: Value of the lateral view

    International Nuclear Information System (INIS)

    Stark, D.D.; Brasch, R.C.; Gooding, C.A.

    1984-01-01

    Frontal chest radiographs can be misleading in the evaluation of central venous catheter placement. Lateral chest radiographs were obtained, in addition to the standard frontal radiographs, in 25 young children. In five (20%) of the children, the catheters were found to be malpositioned, and the frontal radiograph showed evidence of the abnormality in all five. The lateral radiographs also showed evidence of the abnormality in all five children; however, in three of the five, the lateral radiographs provided additional, more specific, diagnostic information. The lateral chest radiographs also demonstrated satisfactory catheter positioning in three other children in whom the frontal radiographs suggested abnormal positioning. Accurate assessment of catheter position was possible in all patients using both frontal and lateral chest radiographs. Injection of contrast material was not necessary to locate malpositioned catheters. Lateral radiographs are recommended whenever an abnormal catheter position is suspected clinically or from findings on the routine frontal radiograph. (orig.)

  12. Radiographic findings of primary lung cancer with delayed detection on chest radiographs

    International Nuclear Information System (INIS)

    Kim, Young Min; Kim, Jin Hwan; Jung, Bin Young; Jun, Kwang Jin; Jeong, Ki Ho; Kim, Ju Ok; Kim, Sun Young; Yang, Chang Kyu

    1999-01-01

    To analyze the causes of delayed detection of lung cancer on chest radiographs. We retrospectively reviewed 105 cases in which an initial diagnosis of lung cancer, based on an examination of plain radiographs, had been missed or misinterpreted. All occurred between October 1993 and April 1997. We reviewed the initial chest radiographs and compared the features noted with those seen on later chest radiographs and computed tomographic (CT) images. Undetected lung cancer was identified in 56 patients (56/105, 53.3%) It had been hidden by superimposed structures (41, 73.2%), overlapped by combined benign diseases (12, 21.4%), or the nodules were subtle (3, 5.4%). Of the 41 lung cancers hidden by a superimposed structure, the central type accounted for 29 (70.7%) and the peripheral type for 12 (29.3%). The 29 central type had been hidden by the left hilum (n=15), the right hilum (n=10), the heart (n=3), or a rib (n=1). The twelve peripheral type were hidden by a rib (n=7), the heart (n=2), the diaphragm (n=2), or the left hilum (n=1). Of the 12 lung cancers overlapped by combined benign diseases, pulmonary tuberculosis (n=6), pleural effusion (n=4), congestive heart failure (n=1), and diffuse interstitial lung disease (n=1) were present at the time of interpretation. The misinterpreted lung cancers were identified in 49 patients (49/105, 46.7%) and were seen to be combined with benign disease (16, 32.6%), or as obstructive pneumonia without a central mass (15, 30.6%), air-space consolidation (7, 14.3%), cavity (7, 14.3%), double lesion (2, 4.1%), or young age below 26 years (2,4.1%). Of the 16 lung cancers misinterpreted as combined disease, pulmonary tuberculosis (n=14) and pleural disease (n=2) had been initially diagnosed. Most commonly, lung cancer was missed or misinterpreted because it was hidden by a normal structure or combined with a benign disease. Perceptual errors can be reduced by appropriate techniques and the scrutiny of trouble spots such as the

  13. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    Science.gov (United States)

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  14. The interest of radiographical investigations of bone diseases in the selection of stallions [orthopedic lesions, abnormal radiographic findings, multivariate analysis

    International Nuclear Information System (INIS)

    Valette, J.P.; Touzot, G.; Denoix, J.M.

    1997-01-01

    Breeding of sport horses requires products with qualities for performance traits. The objectives of this study were to investigate the relation between radiographical examination and descendant of sires. Foots, fetlocks of both thoracic and pelvic limbs, carpus, tarsus and stifles were examined radiographically in 225 3-year old horses descent from 25 stallions. Data were analysed by multivariate analysis. Results indicate that descendant of a stallion presents the same abnormal radiographic findings. It is concluded that bone diseases are of great importance in breeding sport horses and that these abnormalities could have a genetic component [fr

  15. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    Energy Technology Data Exchange (ETDEWEB)

    Albers, Brittany K.; Garner, Hillary W. [Mayo Clinic, Department of Radiology, Jacksonville, FL (United States); Sluzevich, Jason C. [Mayo Clinic, Department of Dermatology, Jacksonville, FL (United States)

    2016-05-15

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)

  16. Radiographic findings in pulmonary hypertension from unresolved embolism

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-04-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms.

  17. Radiographic findings in pulmonary hypertension from unresolved embolism

    International Nuclear Information System (INIS)

    Woodruff, W.W. III; Hoeck, B.E.; Chitwood, W.R. Jr.; Lyerly, H.K.; Sabiston, D.C. Jr.; Chen, J.T.T.

    1985-01-01

    Pulmonary artery hypertension with chronic pulmonary embolism is an uncommon entity that is potentially treatable with pulmonary embolectomy. Although the classic radiographic features have been described, several recent investigators report a significant percentage of these patients with normal chest radiographs. In a series of 22 patients, no normal radiographs were seen. Findings included cardiomegaly (86.4%) with right-sided enlargement (68.4%), right descending pulmonary artery enlargement (54.5%), azygos vein enlargement (27.3%), mosaic oligemia (68.2%), chronic volume loss (27.3%), atelectasis and/or effusion (22.7%), and pleural thickening (13.6%). Good correlation with specific areas of diminished vascularity was seen on chest radiographs compared with pulmonary angiograms

  18. Influence of the radiographer on the pain felt during mammography

    International Nuclear Information System (INIS)

    Goethem, M. van; Verslegers, I.; Biltjes, I.; De Schepper, A.; Mortelmans, D.; Bruyninckx, E.; Hove, E. Van

    2003-01-01

    Mammography is the only useful examination in screening for breast cancer. Mortality from breast cancer can be reduced if women go regularly for a screening mammography. Moreover, it is still the key examination in diagnosis of breast diseases and in the follow-up of patients treated for breast cancer. Pain with mammography can deter women from going for regular screening or follow-up; therefore, it is important to reduce pain experience or discomfort from mammography. In this study we evaluate the impact of the ''radiographer'' on the pain risk during mammography by analysing questionnaires filled in by women and radiographers. Study results reveal that the opinion of the radiographer, the information and communication during the examination and the number of years of experience are important factors in pain and discomfort experience. The attitude of the radiographer plays an important role in the pain experience. (orig.)

  19. 21 CFR 892.1920 - Radiographic head holder.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  20. Radiographic features of bisphosphonate therapy in pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Grissom, L.E.; Theodore Harcke, H. [Dept. of Medical Imaging, Alfred I. duPont Hospital for Children, Nemours Children' s Clinic, Wilmington, DE (United States)

    2003-04-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  1. Radiographic versus electronic root canal working length determination

    Directory of Open Access Journals (Sweden)

    Lumnije Kqiku

    2011-01-01

    Conclusions: The present ex vivo study showed that electronic root canal working length determination is not superior to radiographic methods. Both methods provided a good performance in determining the root canal working length.

  2. Evaluating the role of the diagnostic research radiographer

    International Nuclear Information System (INIS)

    Reid, Karen; Edwards, Hazel

    2011-01-01

    The NHS has an increasingly strong focus on evidence-based medicine to underpin policy making and the development of a culture of evaluation and learning. Good quality research is the foundation for this ethos. Numbers of research projects and clinical trials involving imaging are increasing and therefore more radiographers are contributing to these studies but perhaps on some occasions they may be unaware. This paper describes the benefits of having a dedicated research radiographer within a radiology department to organise and monitor studies. We explain the procedures of the research process, the knowledge and skills that such a radiographer requires and the value of coordination and governance in developing a culture of research in a radiology department. We make suggestions to overcome perceived barriers to engaging with research and discuss the advantages and limitations of the role. Others who are considering appointing a dedicated research radiographer may find our experience helpful.

  3. A new technique for radiographic measurement of acetabular cup orientation.

    Science.gov (United States)

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  4. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    International Nuclear Information System (INIS)

    Albers, Brittany K.; Garner, Hillary W.; Sluzevich, Jason C.

    2016-01-01

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)

  5. Radiographic appearance of the navicular bone in sound horses

    International Nuclear Information System (INIS)

    Kaser-Hotz, B.; Ueltschi, G.

    1992-01-01

    Radiographs of the navicular bone in 523 sound horses were reviewed. Detailed evaluation criteria were used. The incidence of radiographic changes and variations in normal horses were recorded. Results were tested for right-left limb difference and for age relationship. Variation in shape and bone structure was commonly seen in the navicular bone. Radiographic changes with an incidence of less than 2% included flexor cortex defects and calcification on the flexor surface. Fragments at the distal navicular bone border, calcification in the impar ligament and enthesiophytes at the proximal border were radiographic findings with an incidence of 2% to 10%. Abnormal canals at the distal border were found in 11% horses. Elongation of the lateral proximal extremity was commonly found. The mean width of the flexor cortex was 3.6 mm

  6. Measurement of Lumbosacral Angle in Normal Radiographs: A ...

    African Journals Online (AJOL)

    normal lumbar lordosis measurement, the retrospective approach is a credible alternative to the prospective ... complaints, low back pain without any radiographically demonstrable ..... effects of hamstring stretching on sagittal spinal curvatures.

  7. Comparison of codes and standards for radiographic inspection

    International Nuclear Information System (INIS)

    Bingoeldag, M. M.; Aksu, M.; Akguen, A. F.

    1995-01-01

    This report compares the procedurel requirements and acceptance criteria for radiographic inspections specified in the relevant national and international codes and standards. In particular, detailed analysis of inspection conditions such as exposure arrangements, and contrast requirements are given

  8. Application of digital techniques to the restoration of radiographic images

    International Nuclear Information System (INIS)

    Burch, S.F.

    1980-09-01

    The methods of constrained least squares and maximum entropy have been used to restore digital X and γ-ray radiographs. Both methods require the blurring of the image to be a linear, spatially invariant process. Although the blurring processes in radiography can be complex, situations have been identified where these simplifying assumptions are valid. Algorithms for deriving the point-spread function of each image are discussed. These include a pinhole method for X-ray radiographs, and reconstruction from edge profiles for γ-ray radiographs. The results from the restoration of geometrically blurred radiographs of sparking plugs are given. Maximum entropy gives results superior to those obtained by constrained least squares. The resolution is improved by a factor of about three when maximum entropy is used, and by a factor of about two for constrained least squares. (author)

  9. Radiographic features of bisphosphonate therapy in pediatric patients

    International Nuclear Information System (INIS)

    Grissom, L.E.; Theodore Harcke, H.

    2003-01-01

    Background: Pediatric patients are being treated with bisphosphonates for low bone mineral density. Skeletal radiographic findings have been described with bisphosphonates given orally and intravenously. Objective: To determine and describe the radiographic findings of cyclic intravenous bisphosphonate therapy in the growing skeleton. Materials and methods: Retrospective review of radiographs of 32 patients with osteogenesis imperfecta or cerebral palsy treated with intravenous bisphosphonates on a quarterly schedule. Results: Principal observations were metaphyseal bands and increased bone mineral density. The bands varied in spacing according to the age of the patient, rate of growth, and the location of the metaphysis. Fractures continued to be seen in patients with osteogenesis imperfecta. Conclusion: Cyclic bisphosphonate therapy results in distinctive radiographic findings in the growing skeleton. (orig.)

  10. Radiographic visualization of magma dynamics in an erupting volcano.

    Science.gov (United States)

    Tanaka, Hiroyuki K M; Kusagaya, Taro; Shinohara, Hiroshi

    2014-03-10

    Radiographic imaging of magma dynamics in a volcanic conduit provides detailed information about ascent and descent of magma, the magma flow rate, the conduit diameter and inflation and deflation of magma due to volatile expansion and release. Here we report the first radiographic observation of the ascent and descent of magma along a conduit utilizing atmospheric (cosmic ray) muons (muography) with dynamic radiographic imaging. Time sequential radiographic images show that the top of the magma column ascends right beneath the crater floor through which the eruption column was observed. In addition to the visualization of this magma inflation, we report a sequence of images that show magma descending. We further propose that the monitoring of temporal variations in the gas volume fraction of magma as well as its position in a conduit can be used to support existing eruption prediction procedures.

  11. Full-body digital radiographic imaging of the injured child

    African Journals Online (AJOL)

    radiographic exposure increasing the cumulative dose of ionising ... radiography system in the Trauma Unit at Red Cross War Memorial ..... that resveratrol and similar drugs will treat age-related disorders such as type 2 diabetes and cancer.

  12. Study of scattering in bi-dimensional neutron radiographic images

    International Nuclear Information System (INIS)

    Oliveira, K.A.M. de; Crispim, V.R.; Silva, F.C.

    2009-01-01

    The effect of neutron scattering frequently causes distortions in neutron radiographic images and, thus, reduces the quality. In this project, a type of filter, comprised of cadmium (a neutron absorber), was used in the form of a grid to correct this effect. This device generated image data in the discrete shadow bands of the absorber, components relative to neutron scattering on the test object and surroundings. Scattering image data processing, together with the original neutron radiographic image, resulted in a corrected image with improved edge delineation and, thus, greater definition in the neutron radiographic image of the test object. The objective of this study is to propose a theoretical/experimental methodology that is capable of eliminating the components relative to neutron scattering in neutron radiographic images, coming from the material that composes the test object and the materials that compose the surrounding area. (author)

  13. Radiographic and scintigraphic evaluation of total knee arthroplasty

    International Nuclear Information System (INIS)

    Schneider, R.; Soudry, M.

    1986-01-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent

  14. Radiographic inspection and densitometric evaluation of CP-5 reactor fuel

    International Nuclear Information System (INIS)

    Staroba, J.F.; Knoerzer, T.W.

    1978-02-01

    This report covers the radiographic and densitometric techniques used as part of a quality verification program for CP-5 reactor fuel by the Nondestructive Assay Section of the Special Materials Division. Other nondestructive tests used were ultrasonic and gamma-ray spectrometry. The main objectives were to perform a one-hundred percent radiographic inspection of the fuel tubes and to derive a quantitative relationship between fuel thickness and film density with the use of fabricated fuel step wedges. By the use of tangential x-ray techniques, measurements were made of fuel peaks or ''hot spots'' that protruded above the main fuel line. Other general problems in radiographic inspection and solutions for the upgrading of the total radiographic inspection program are also discussed

  15. Standardization principles of radiographic investigation of concrete structures

    International Nuclear Information System (INIS)

    Runkiewicz, L.

    1979-01-01

    The PN-78/B-06264 Polish Standard concerning the radiographic methods of concrete structure control is discussed. It concerns the inner structure of the building elements, dimensions and position of honeycombs and reinforcement. (author)

  16. Use your good judgement - Radiographers' knowledge in image production work

    International Nuclear Information System (INIS)

    Larsson, W.; Lundberg, N.; Hillergard, K.

    2009-01-01

    It has been shown that the demand for radiography services has markedly increased and radiographers' work has become more complex as their role has changed. More specifically, it entails new activities, new ways of communicating and new responsibilities. This means that radiographers work in new ways and need new ways to learn. The knowledge needed in this learning process is still unexplored. The aim of this study is to identify and present how radiographers use knowledge in image production work using PACS. This is explored by studying how radiographers use their knowledge in practice. The study adopts a qualitative approach, using participant observation of and semi-structured interviews with radiographers at five Swedish hospitals. To identify properties of knowledge, Blackler's theory of knowledge components was applied. The results of this study show that radiographers use the knowledge components in different situations in their image production work. They use embrained knowledge in planning X-ray examinations and in viewing images. Encoded knowledge is required for the use of various kinds of documentation, such as manuals and protocols. Embodied knowledge is action-oriented and involves 'gut feelings'. The study also illustrates that radiographers use their knowledge at different levels as routine actors or as reflective actors, in a more static way or with a flexible attitude, more unreflectively or more as critical reflectors, and finally more as performing automatic action or problem-solving action. This study concludes that radiographers need more reflective actors in the image production process when working with PACS. The study also illustrates that radiographers need to be flexible in their work; there is little room for static work. In work they need to analyze images, it is not enough to 'check them off'; they cannot just read documents, you need to interpret them to optimize work performance. Overall, radiographers need to have a critical and

  17. Reestablishment of radiographic kidney size in Miniature Schnauzer dogs.

    Science.gov (United States)

    Sohn, Jungmin; Yun, Sookyung; Lee, Jeosoon; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2017-01-10

    Kidney size may be altered in renal diseases, and the detection of kidney size alteration has diagnostic and prognostic values. We hypothesized that radiographic kidney size, the kidney length to the second lumbar vertebra (L2) length ratio, in normal Miniature Schnauzer dogs may be overestimated due to their shorter vertebral length. This study was conducted to evaluate radiographic and ultrasonographic kidney size and L2 length in clinically normal Miniature Schnauzers and other dog breeds to evaluate the effect of vertebral length on radiographic kidney size and to reestablish radiographic kidney size in normal Miniature Schnauzers. Abdominal radiographs and ultrasonograms from 49 Miniature Schnauzers and 54 other breeds without clinical evidence of renal disease and lumbar vertebral abnormality were retrospectively evaluated. Radiographic kidney size, in the Miniature Schnauzer (3.31 ± 0.26) was significantly larger than that in other breeds (2.94 ± 0.27). Relative L2 length, the L2 length to width ratio, in the Miniature Schnauzer (1.11 ± 0.06) was significantly shorter than that in other breeds (1.21 ± 0.09). However, ultrasonographic kidney sizes, kidney length to aorta diameter ratios, were within or very close to normal range both in the Miniature Schnauzer (6.75 ± 0.67) and other breeds (7.16 ± 1.01). Thus, Miniature Schnauzer dogs have breed-specific short vertebrae and consequently a larger radiographic kidney size, which was greater than standard reference in normal adult dogs. Care should be taken when evaluating radiographic kidney size in Miniature Schnauzers to prevent falsely diagnosed renomegaly.

  18. Adult Sail Sign: Radiographic and Computed Tomographic Features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo (Dept. of Radiology, Cheil General Hospital, Kwandong Univ. College of Medicine, Seoul (KR))

    2008-02-15

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  19. Silver impregnation in situ: an aid to radiographic interpretation

    International Nuclear Information System (INIS)

    Boyd, J.; Rantanen, N.W.

    1984-01-01

    In evaluating radiographs of the limb joints and head, students encounter difficulty where superimposition occurs. By replacing calcium with silver salts in the bone, enhanced radiopacity can be produced. In this study, silver impregnation was used to increase the radiopacity of individual carpal and tarsal bones, selected bones of the skull and the sinuses, and guttural pouch of the horse. This provides an interpretation aid for teaching radiographic anatomy of these regions

  20. The radiographic findings of adult congenital megacolon disease

    International Nuclear Information System (INIS)

    Deng Xiaotao; Yu Jingying; Zhang Yongchun

    2000-01-01

    Objective: To describe the radiographic findings of adult megacolon. Methods: Barium enema examination was performed in 6 patients with megacolon proved by operation. Results: The principal radiographic findings were a markedly dilated colon, the largest diameter was 22 cm, and a narrowed rectum, its length was 3-7 cm; with a cone or funnel shaped transitional segment, it is about 2-6 cm long. Conclusion: The barium enema examination is the most reliable and simple method in diagnosing adult congenital megacolon

  1. Adult Sail Sign: Radiographic and Computed Tomographic Features

    International Nuclear Information System (INIS)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Y oun, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-01-01

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  2. Role of a radiographer in mammography- new perspective

    International Nuclear Information System (INIS)

    Malik, S.

    2006-01-01

    giving the background to breast cancer in kenya. The importance of public education. The significance of early detection of breast cancer and patient survival. the emphasis of change of mind set of machine oriented radiographer to a clinically focused role. this involves a better understanding of the breast, the disease pattern, clinical examination of the breast and correlation with radiographic findings. The importance of other imaging modalities used to supplement mammography

  3. Detection of corrosion by radiographic techniques

    International Nuclear Information System (INIS)

    Ahmad, M.; Ashraf, M.M.; Khurshid, U.

    2004-01-01

    Radiation processing technologies are playing an increasing role during manufacturing and subsequent use of everyday products. These technologies are now well established and are extensively practiced in industries, to ensure quality and safety of machinery. Corrosion reduces the operational life of the component, its efficiency and helps generate waste. There is an increasing need to detect and characterize the formation of corrosion in industrial components and assemblies at an early stage. Radiation methods and techniques are applied worldwide to examine defects and corrosion-formation in industrial components. For safety and economic reason, appropriate monitoring of the machinery and industrial components would help reduce accidental risks during operation and avoid production-losses. In the present study, X-ray and neutron-radiography techniques were applied for the inspection and evaluation of corrosion in metallic samples for thickness values of the order of 5 mm or less. Relative contrast at various degrees of metal corrosion product loss was computed theoretical and also measured experimentally by applying radiographic techniques. The relative contrast-sensitivity was also measured in two different ways by X-ray and neutron radiography, to compare the visibility of coarse and fine features. Thick metallic areas, free from sealant and variable paint thickness, were imaged with thermal neutrons beam. Low KV X-rays were also applied for imaging corrosion in metallic components. To optimize exposure-time at low KV in X-ray radiography, a medical film/screen combination was used. X-ray radiography approved to be the more promising technique for imaging of corrosion, as compared to neutron radiography. (author)

  4. Computed image analysis of neutron radiographs

    International Nuclear Information System (INIS)

    Dinca, M.; Anghel, E.; Preda, M.; Pavelescu, M.

    2008-01-01

    Similar with X-radiography, using neutron like penetrating particle, there is in practice a nondestructive technique named neutron radiology. When the registration of information is done on a film with the help of a conversion foil (with high cross section for neutrons) that emits secondary radiation (β,γ) that creates a latent image, the technique is named neutron radiography. A radiographic industrial film that contains the image of the internal structure of an object, obtained by neutron radiography, must be subsequently analyzed to obtain qualitative and quantitative information about the structural integrity of that object. There is possible to do a computed analysis of a film using a facility with next main components: an illuminator for film, a CCD video camera and a computer (PC) with suitable software. The qualitative analysis intends to put in evidence possibly anomalies of the structure due to manufacturing processes or induced by working processes (for example, the irradiation activity in the case of the nuclear fuel). The quantitative determination is based on measurements of some image parameters: dimensions, optical densities. The illuminator has been built specially to perform this application but can be used for simple visual observation. The illuminated area is 9x40 cm. The frame of the system is a comparer of Abbe Carl Zeiss Jena type, which has been adapted to achieve this application. The video camera assures the capture of image that is stored and processed by computer. A special program SIMAG-NG has been developed at INR Pitesti that beside of the program SMTV II of the special acquisition module SM 5010 can analyze the images of a film. The major application of the system was the quantitative analysis of a film that contains the images of some nuclear fuel pins beside a dimensional standard. The system was used to measure the length of the pellets of the TRIGA nuclear fuel. (authors)

  5. High-frame-rate digital radiographic videography

    Science.gov (United States)

    King, Nicholas S. P.; Cverna, Frank H.; Albright, Kevin L.; Jaramillo, Steven A.; Yates, George J.; McDonald, Thomas E.; Flynn, Michael J.; Tashman, Scott

    1994-10-01

    High speed x-ray imaging can be an important tool for observing internal processes in a wide range of applications. In this paper we describe preliminary implementation of a system having the eventual goal of observing the internal dynamics of bone and joint reactions during loading. Two Los Alamos National Laboratory (LANL) gated and image intensified camera systems were used to record images from an x-ray image convertor tube to demonstrate the potential of high frame-rate digital radiographic videography in the analysis of bone and joint dynamics of the human body. Preliminary experiments were done at LANL to test the systems. Initial high frame-rate imaging (from 500 to 1000 frames/s) of a swinging pendulum mounted to the face of an X-ray image convertor tube demonstrated high contrast response and baseline sensitivity. The systems were then evaluated at the Motion Analysis Laboratory of Henry Ford Health Systems Bone and Joint Center. Imaging of a 9 inch acrylic disk with embedded lead markers rotating at approximately 1000 RPM, demonstrated the system response to a high velocity/high contrast target. By gating the P-20 phosphor image from the X-ray image convertor with a second image intensifier (II) and using a 100 microsecond wide optical gate through the second II, enough prompt light decay from the x-ray image convertor phosphor had taken place to achieve reduction of most of the motion blurring. Measurement of the marker velocity was made by using video frames acquired at 500 frames/s. The data obtained from both experiments successfully demonstrated the feasibility of the technique. Several key areas for improvement are discussed along with salient test results and experiment details.

  6. Radiographic and MRI findings in ochronosis

    International Nuclear Information System (INIS)

    Perrone, Anna; Impara, Luca; Bruni, Antonio; Primicerio, Paolo; Marini, Mario

    2005-01-01

    Purpose. Ochronotic arthropathy is the articular manifestation of alkaptonuria, a rare hereditary metabolic disease that leads to the deposition of homogentisinic acid particularly in the joints where it causes articular degeneration and inflammation. We studied the radiological patterns of the disorder using both traditional X rays both MRI and comparing the results obtained with the two techniques. Materials and methods. The study included five patients (4 males, 1 female, mean age 51 years); we studied the most frequently affected sites, the knee, the shoulder and the spine. As regards the conventional study we used a radiographic score which considered the state of the articular space and the presence of calcifications. MRI of the peripheral joints was performed on the most symptomatic site or, if asymptomatic, on the most severely affected site as established by radiography; in all cases T1- and T2 weighted sequences in the axial, sagittal and coronal planes were acquired. Results. Both the X-ray and MRI study revealed the typical alterations of ochronosis in the cases with a known diagnosis: articular space narrowing up to osseous ankylosis, calcifications, osteophytosis, reactive sclerosis of the articular surfaces; MRI was how evermore accurate. in identifying the alterations and revealing lesions not visible at conventional radiology, such as ligament lesions. In the case of newly diagnosed ochronotic arthropathy MRI proved valuable for its ability to detect alterations that are poorly appreciable at conventional radiology. Conclusions. Modern diagnostic imaging, above all MRI, allowed to identify the peculiar characteristic features of ochronosis and is fundamental both for the diagnosis and for differentiating ochronosis from other articular disorders [it

  7. Radiographic anatomy of Japanese domestic cats

    International Nuclear Information System (INIS)

    Kimura, H.; Suganuma, T.; Ogata, M.; Wakui, S.; Kano, Y.; Asari, M.

    1994-01-01

    Of 51 Japanese domestic cats the number of vertebrae, the distance between the occipital bone and the 1st cervical vertebra (C 1 ), and that between C 1 and the 2nd cervical vertebra (C 2 ), as well as the sizes of the cardiac and local great vessels and kidneys were measured radiographically. The proportion of the C 1 vertebral canal to the distance between the caudal margin of the occipital bone and C1 was 1 0.61, and that of the C 1 diameter to the minimum distance between C 1 and C 2 was 1 0.19. The diameters of the trachea, thoracic aorta and caudal vena cave were almost similar and the diameters of the both pulmonary trank and pulmonary vein were almost equivalent to the smallest diameters of the 8th and 10th ribs, respectively. The depth of the thorax was greater in Japanese domestic cats than in the American mixed breed (Hamlin et al., 1963). The V-D view of the abdominal region showed that the proportions of L2 to the longitudinal length of the right and left kidneys were 1: 2.49 and 1: 2.38, respectively. The ratio of L2 to the transversal length of the right and left kidneys were 1 3.05 and 1 3.03, respectively. On the lateral view, the proportions of L 2 length to the longitudinal length of the right and left kidneys were 1 2.39, while those to the transversal length of the right and left kidneys were 1 5.25 and 1 5.20, respectively

  8. A radiographic study of nasopalatine duct cysts

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1993-02-15

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  9. A radiographic study of nasopalatine duct cysts

    International Nuclear Information System (INIS)

    Jun, Chan Duck; Hwang, Eui Hwan; Lee, Sang Rae

    1993-01-01

    The purpose of this study was to evaluate the clinical and radiographic features of 35 cases of nasopalatine duct cyst by means of the analysis of periapical and/or occlusal radiograms in 35 persons visited the Department of Oral and Maxillofacial Radiology, School of Dentistry, Kyung Hee University and Chonbuk National University. The obtained results were as follows: 1. The incidence of nasopalatine duct cysts was higher in males (74.3%) than in females (25.7%). 2. The nasopalatine duct cysts were the most frequently occurred in the 4th decades (34.3%). The 6th and 7th decades (17.1%, 17.1%) were next in order to frequency followed by the 5th decades (14.3%), the 3rd decades (8.6%), the 2nd decades (5.7%), and 8th decades (2.9%). 3. In the signs and symptoms of nasopalatine duct cysts, 25.7% were swelling, 17.1% were swelling and tenderness, 20.0% were swelling and pain, and 37.2% were a symptom. 4. In the shape of nasopalatine duct cysts, 40.0% were round type, 48.6% 11.8% were heart type. 5. In symmetry of the nasopalatine duct cysts, 11.4% were 6-10 mm, 48.6% were 11-20 mm, 25.7% were 21-30 mm, and 14.3% were 31-40 mm. 6. In the periphery of nasopalatine duct cysts, 82.9% were distinct, 17.1% were relatively distinct. 7. In the change of root, 51.5% were intact, 17.1% were root divergence, 20.0% were root resorption, and 11.4% were root divergence and resorption.

  10. Technical errors in complete mouth radiographic survey according to radiographic techniques and film holding methods

    International Nuclear Information System (INIS)

    Choi, Karp Sik; Byun, Chong Soo; Choi, Soon Chul

    1986-01-01

    The purpose of this study was to investigate the numbers and causes of retakes in 300 complete mouth radiographic surveys made by 75 senior dental students. According to radiographic techniques and film holding methods, they were divided into 4 groups: Group I: Bisecting-angle technique with patient's fingers. Group II: Bisecting-angle technique with Rinn Snap-A-Ray device. Group III: Bisecting-angle technique with Rinn XCP instrument (short cone) Group IV: Bisecting-angle technique with Rinn XCP instrument (long cone). The most frequent cases of retakes, the most frequent tooth area examined, of retakes and average number of retakes per complete mouth survey were evaluated. The obtained results were as follows: Group I: Incorrect film placement (47.8), upper canine region, and 0.89. Group II: Incorrect film placement (44.0), upper canine region, and 1.12. Group III: Incorrect film placement (79.2), upper canine region, and 2.05. Group IV: Incorrect film placement (67.7), upper canine region, and 1.69.

  11. A novel tool for automated evaluation of radiographic weld images

    International Nuclear Information System (INIS)

    Rajagopalan, C.; Venkatraman, B.; Jayakumar, T.; Kalyanasundaram, P.; Raj, B.

    2004-01-01

    Radiography is one of the oldest and the most widely used NDT method for the detection of volumetric defects in welds and castings. Once a radiograph of a weld or a casting or an assembly is taken, the radiographer examines the same. The task of the radiographer consists of identifying the defects and quantitatively evaluating the same based on codes and specifications. Radiographic interpretation primarily depends on the expertise of the individual radiographer. To overcome the subjectivity involved in human interpretation, it is thus desirable to develop a computer based automated system to aid in the interpretation of radiographs. Towards this goal, the authors have developed a flowchart chalking out the various stages involved. Typical weld images of tube to tubesheet weld joints were digitised using high resolution digitiser. The images were segmented and 52 invariant moments were computed to be used as features. The results of these are presented in this paper. Once the features (invariant moments) are extracted and ranked, a neural network classifier based on error back-propagation has to classify the (top ranking) features and evaluate the image for acceptance or rejection. (author)

  12. Distortion of digital panoramic radiographs used for implant site assessment

    Directory of Open Access Journals (Sweden)

    Rayyan Abdulhamid Kayal

    2016-01-01

    Full Text Available Aims: This study is conducted to determine the amount of distortion of digital panoramic radiographs. Materials and Methods: Panoramic radiographs of all patients who received dental implants in the years 2012 and 2013 were selected from the records at the faculty of dentistry, King Abdulaziz University. Radiographs were analyzed using the R4 Kodak Software for linear measurements of implants length and width. The measurements were compared to the actual size of the implant, and the amount of distortion was calculated. Results: A total of 169 implants were analyzed. Horizontally, there was a statistically significant increase of 0.4 mm in width in the radiographic measurement compared to the actual size in the incisor region. Vertically, the sample overall exhibited a decrease by 0.4 mm compared to the actual size. Incisors had the highest difference with a decrease of 1.7 mm in the radiographic measurements compared to actual size. The highest distortion was found in the incisor region for both diameter and length (1.1 and 0.86, respectively. Conclusion: Digital panoramic radiographs show minimal to no distortion. The highest distortion is found in the anterior area.

  13. Chest radiographic findings in neurotuberculosis without pulmonary signs and symptoms

    International Nuclear Information System (INIS)

    Aurangzeb, S.; Badshah, M.; Khan, B.R.S.

    2008-01-01

    To determine the chest radiographic findings in patients of adult neurotuberculosis, with no pulmonary signs and symptoms. A total of 100 patients fulfilling pre-defined criteria of neurotuberculosis were included. Chest radiographic (CXR) evidence of pulmonary TB was looked for in those patients and its frequency, pattern and association with the clinical grades at presentation was determined by using Chi-square test. Out of the 100 patients of neurotuberculosis, with no clinical evidence of pulmonary TB, radiographic evidence of pulmonary TB was seen in only 30% patients. The predominant patterns on CXR were apical infiltration (26.6%), military mottling (20%) and hilar enlargement (16.6%). Positive CXR was found in 16.7% patients in clinical grade I and 40% and 43.3% in patients in grade II and III respectively. There was a strong association of grade II and grade III with positive chest radiographic findings (p= 0.03). Patients of neurotuberculosis may have chest radiographic evidence of pulmonary TB even in the absence of pulmonary signs and symptoms at presentation. There is a strong association of clinical grade II and grade III with positive chest radiographic findings. (author)

  14. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  15. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  16. Evaluation of a standardised radiographic technique of the equine hoof

    International Nuclear Information System (INIS)

    Kummer, M.; Lischer, C.; Ohlerth, S.; Vargas, J.; Auer, J.

    2004-01-01

    Radiography of the equine hoof is often used to obtain a diagnosis. Quantitative interpretation, especially for research purposes requires high quality and accuracy of radiographs. The purpose of this study was to describe and evaluate a radiographic technique for the lateromedial (LM) and the dorsopalmar (DP) view of the equine hoof. Ten radiographs for each view from one cadaver limb and from both front feet in a standing horse were taken in order to assess repeatability of the radiographic technique. The method requires easy to use adjustable and portable equipment and strictly defined external radio opaque markers on the hoof capsule. The digitalised radiographs were processed and analysed with the software package Metron PXTM, measuring 13 parameters in the LM view and 10 parameters in the DP view, respectively. Results show that with few exceptions measurements of these parameters revealed a coefficient of variation that was smaller than 0.05. It was concluded that this easy to use standardised radiographic technique ensures excellent accuracy and repeatability for both the LM and DP view. Hence, this method provides an adequate tool for quantitative assessment of the equine hoof, inter- and intraindividually

  17. Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

    Energy Technology Data Exchange (ETDEWEB)

    Radhakrishnan, Pillai Devu; Varma, Nilambur Kovilakam Sapna; Ajith, Vallikat Velath [Dept. of Orthodontics, Amrita School of Dentistry, Kochi (India)

    2017-06-15

    The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measured using both a lateral cephalogram and a panoramic radiograph. In the lateral cephalograms, the gonial angle was measured at the point of intersection of the ramus plane and the mandibular plane. In the panoramic radiographs, the gonial angle was measured by drawing a line tangent to the lower border of the mandible and another line tangent to the distal border of the ascending ramus and the condyle on both sides. The data obtained from both radiographs were statistically compared. No statistically significant difference was observed between the gonial angle measured using the lateral cephalograms and that determined using the panoramic radiographs. Further, there was no statistically significant difference in the measured gonial angle with respect to gender. The results also showed a statistically insignificant difference in the mean of the right and the left gonial angles measured using the panoramic radiographs. As the gonial angle measurements using panoramic radiographs and lateral cephalograms showed no statistically significant difference, panoramic radiography can be considered in orthodontics for measuring the gonial angle without any interference due to superimposed images.

  18. When disaster strikes; the role of the forensic radiographer

    International Nuclear Information System (INIS)

    Walsh, Mary; Reeves, Pauline; Scott, Susan

    2004-01-01

    Forensic radiography is a vital tool utilised in the many facets of Forensic Medicine. This paper investigates the role of the forensic radiographer in a mass disaster situation; it also explores the psychological impact of this type of work on radiographers. A literature review indicated that limited work had been documented on the role of the radiographer in mass disasters. This ultimately creates doubt about whether or not the radiographer is acknowledged for the vital role he/she plays and if proper provisions were in place to assess any emotional damage in the aftermath of an emotionally and physically straining situation. A qualitative method of research was used (semi-structured interviews) in order to elicit radiographers' feelings and perceptions. This method is best suited to this research topic because it is a delicate subject. Four interviews were carried out and the responses are presented in themes including emergency versus mass grave experiences (including issues of time and preparation). Other themes include the role of the radiographer and interaction with other members of the team, as well as a discussion of the aftermath of their experiences, including the feelings of pride experienced

  19. Radiographic diagnoses and treatment decisions on approximal caries

    International Nuclear Information System (INIS)

    Espelid, I.

    1987-01-01

    Mineral loss which represents a threshold value for radiographic diagnosis, cannot be defined exactly. For clinical use 10% mineral loss in the direction of the X-ray beam may constitute a border line lesion for radiographic detection, and caries lesions without cavitation seemed to be beyond this diagnostic threshold. The degree of caries estimated by using radiographs is fairly closely related to the depth of the tissue changes recorded in the prepared cavity. Radiographic examinations more often lead to underestimation than overestimation of the degree of caries. Radiographic caries diagnoses made at different degrees of penetration toward the pulp showed insignificant variations with respect to quality, but the observers were more confident of caries being present (used more strict criterion) when they scored caries in inner dentin. Consensus on diagnostic criteria and improved diagnostic quality are considerably more important to the quality of therapeutic decisions on approximal caries than viewing conditions and film density. A semi-radiopaque material in Class II fillings seems to offer advantages compared to amalgam in respect of the diagnosis of secondary caries and marginal defects. There is a danger that dentists will restore approximal caries lesions too early and before these can be diagnosed in dentin radiographically

  20. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    International Nuclear Information System (INIS)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A.

    2018-01-01

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  1. Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs. An accuracy and feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Hakimian, David; Khoury, Amal; Mosheiff, Rami; Liebergall, Meir; Weil, Yoram A. [Hadassah Hebrew University Hospital, Department of Orthopaedics, Jerusalem (Israel)

    2018-04-15

    Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA copyright software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft. (orig.)

  2. Radiographic diagnosis of diaphragmatic hernia: review of 60 cases in dogs and cats.

    Science.gov (United States)

    Hyun, Changbaig

    2004-06-01

    Sixty cases of diaphragmatic hernia in dogs and cats were radiologically reviewed and categorized by their characteristic radiographic signs. Any particular predilection for age, sex, or breed was not observed. Liver, stomach and small intestine were more commonly herniated. At least two radiographs, at different angles, were required for a valid diagnosis, because some radiographic signs were not visible in a single radiographic view and more clearly detectable in two radiographic views. In addition to previously reported radiographic signs for diaphragmatic hernia, we found that the location of the stomach axis and the displacement of tracheal and bronchial segments were also useful radiographic signs.

  3. Radiographic alterations of the frontal sinus morphology according to variations of the vertical angle in posteroanterior radiographs of the skull

    Directory of Open Access Journals (Sweden)

    Rhonan Ferreira Silva

    2014-03-01

    The frontal sinuses play a highly relevant role in comparative human identification processes. Since forensic radiology is a branch in the forensic sciences, adequate radiological analysis of the frontal sinuses is essential for comparative human identifications. The current study investigates radiographic morphological changes in the frontal sinuses according to vertical angle distortions in posteroanterior (PA radiographs. A standard PA radiograph of the skull of an adult was obtained. Eight addition PA radiographs were taken at different vertical angles. Frontal sinuses were analyzed qualitatively and quantitatively according to Ribeiro´s (2000 technique. Both qualitative and quantitative analyses revealed significant image distortions. Further, overlapping anatomical structures were reported when PA radiographs were analyzed in negative angulation distortions (from -10° to -40°. Positive and negative angular distortions up to 20º slightly affected the qualitative morphological analysis. However, 10° positive and negative distortions provided a significant interference in quantitative analysis and impaired the measuring process. Most forensic techniques for the analysis of frontal sinuses comprise measurements of morphological distances. Distortions of approximately 10° or over in vertical angulation of cranial PA radiographs should be avoided so that more accurate comparative human identifications could be achieved.

  4. Comparison of film/screen and PCR digital lateral cervical spine radiographs

    International Nuclear Information System (INIS)

    Silver, D.I.; Kreipke, D.L.; Tarver, R.; Braunstein, E.M.

    1988-01-01

    The authors compared film/screen and Phillips computed radiography (PCR) radiographs of the cervical spine. In 109 patients. fiilm/screen and digital radiographs were compared for adequate visualization (readability) of bone, soft tissue, and trachea. The lowest cervical vertebra seen was noted in each case. The radiographs were interpreted by four radiologists, and both interobserver and intraobserver consistency were measured. Of the PCR radiographs, 97% were readable with a viewbox alone. Of the film/screen radiographs, 9% were readable with a viewbox. With a hotlight, 83% of the film/screen radiographs became readable. Bone, soft tissue, and trachea were better seen on PCR radiographs than on film/screen radiographs (P<.001). There was less interobserver variation on digital radiographs. Readability of cervical spine radiographs was significantly improved with PCR

  5. Stereoscopic radiographic images with thermal neutrons

    International Nuclear Information System (INIS)

    Silvani, M.I.; Almeida, G.L.; Rogers, J.D.; Lopes, R.T.

    2011-01-01

    Spatial structure of an object can be perceived by the stereoscopic vision provided by eyes or by the parallax produced by movement of the object with regard to the observer. For an opaque object, a technique to render it transparent should be used, in order to make visible the spatial distribution of its inner structure, for any of the two approaches used. In this work, a beam of thermal neutrons at the main port of the Argonauta research reactor of the Instituto de Engenharia Nuclear in Rio de Janeiro/Brazil has been used as radiation to render the inspected objects partially transparent. A neutron sensitive Imaging Plate has been employed as a detector and after exposure it has been developed by a reader using a 0.5 μm laser beam, which defines the finest achievable spatial resolution of the acquired digital image. This image, a radiographic attenuation map of the object, does not represent any specific cross-section but a convoluted projection for each specific attitude of the object with regard to the detector. After taking two of these projections at different object attitudes, they are properly processed and the final image is viewed by a red and green eyeglass. For monochromatic images this processing involves transformation of black and white radiographies into red and white and green and white ones, which are afterwards merged to yield a single image. All the processes are carried out with the software ImageJ. Divergence of the neutron beam unfortunately spoils both spatial and contrast resolutions, which become poorer as object-detector distance increases. Therefore, in order to evaluate the range of spatial resolution corresponding to the 3D image being observed, a curve expressing spatial resolution against object-detector gap has been deduced from the Modulation Transfer Functions experimentally. Typical exposure times, under a reactor power of 170 W, were 6 min for both quantitative and qualitative measurements. In spite of its intrinsic constraints

  6. Stereoscopic radiographic images with thermal neutrons

    Science.gov (United States)

    Silvani, M. I.; Almeida, G. L.; Rogers, J. D.; Lopes, R. T.

    2011-10-01

    Spatial structure of an object can be perceived by the stereoscopic vision provided by eyes or by the parallax produced by movement of the object with regard to the observer. For an opaque object, a technique to render it transparent should be used, in order to make visible the spatial distribution of its inner structure, for any of the two approaches used. In this work, a beam of thermal neutrons at the main port of the Argonauta research reactor of the Instituto de Engenharia Nuclear in Rio de Janeiro/Brazil has been used as radiation to render the inspected objects partially transparent. A neutron sensitive Imaging Plate has been employed as a detector and after exposure it has been developed by a reader using a 0.5 μm laser beam, which defines the finest achievable spatial resolution of the acquired digital image. This image, a radiographic attenuation map of the object, does not represent any specific cross-section but a convoluted projection for each specific attitude of the object with regard to the detector. After taking two of these projections at different object attitudes, they are properly processed and the final image is viewed by a red and green eyeglass. For monochromatic images this processing involves transformation of black and white radiographies into red and white and green and white ones, which are afterwards merged to yield a single image. All the processes are carried out with the software ImageJ. Divergence of the neutron beam unfortunately spoils both spatial and contrast resolutions, which become poorer as object-detector distance increases. Therefore, in order to evaluate the range of spatial resolution corresponding to the 3D image being observed, a curve expressing spatial resolution against object-detector gap has been deduced from the Modulation Transfer Functions experimentally. Typical exposure times, under a reactor power of 170 W, were 6 min for both quantitative and qualitative measurements. In spite of its intrinsic constraints

  7. Radiographic diagnosis of diaphragmatic hernia: review of 60 cases in dogs and cats

    International Nuclear Information System (INIS)

    Hyun, C.B.

    2004-01-01

    Sixty cases of diaphragmatic hernia in dogs and cats were radiologically reviewed and categorized by their characteristic radiographic signs. Any particular predilection for age, sex, or breed was not observed. Liver, stomach and small intestine were more commonly herniated. At least two radiographs, at different angles, were required for a valid diagnosis, because some radiographic signs were not visible in a single radiographic view and more clearly detectable in two radiographic views

  8. Pulp polyp - A periapical lesion: Radiographic observational study

    Directory of Open Access Journals (Sweden)

    Kandagal V Suresh

    2015-01-01

    Full Text Available Introduction: Pulp polyp (PP is a chronic hyperplastic condition resulting in formation of granulation tissue and proliferative mass. The radiographic appearance of PP has innumerable presentations. Diagnosing and treatment planning of periapical lesions, heavily relies on the radiographic changes surrounding the root structures. Objective: To evaluate different radiographic periapical changes in clinically detected PP patients. Materials and Methods: Patients reporting to Department of Oral Medicine and Radiology and who were clinically diagnosed with PP by an oral diagnostician were subjected to radiographic examination. Digital intraoral periapical radiographs of 50 patients with PP were taken. Various periapical changes in the digital radiographs were recorded by a skilled oral radiologist. The data obtained was subjected to statistical analysis using SPSS ver 17.0 and P-value was set at <0.05 as significant. Result: Periapical changes like periodontal space widening (PDLW, loss of lamina dura, periapical abscess, periapical granuloma, hypercementosis, condensing osteitis and root resorption were noted. Periodontal space widening was seen in all patients (100%, loss of lamina dura was noted in 72%, periapical rarefying osteitis in 56%, condensing osteitis in 8%, hypercementosis, periapical granuloma, and root resorption were seen in 4% of PP patients. Majority of PP were asymptomatic (66%. Pulp polyp was commonly seen in mandibular first molar followed by mandibular second molar and maxillary first molar. Statistically significant difference was noticed between periapical changes in PP patients (P value <0.0001. All PP patients showed definite periapical changes suggesting it to be a periapical lesion. Conclusion: Pulp polyp is confined to the pulpal portion of the tooth which, may or may not cause changes in periapical region. The results of the present study showed that majority of the PP patients were associated with definite periapical

  9. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  10. Effects of Different Viewing Conditions on Radiographic Interpretation

    Directory of Open Access Journals (Sweden)

    Mahkameh Moshfeghi

    2016-08-01

    Full Text Available Objectives: Optimum viewing conditions facilitate identification of radiographic details and decrease the need for retakes, patients’ costs and radiation dose. This study sought to evaluate the effects of different viewing conditions on radiographic interpretation.Materials and Methods: This diagnostic study was performed by evaluating radiograph of a 7mm-thick aluminum block, in which 10 holes with 2mm diameters were randomly drilled with depths ranging from 0.05 mm to 0.50mm. The radiograph was viewed by four oral radiologists independently under four viewing conditions, including a white light viewing light box in a lit room, yellow light viewing light box in a lit room, white light viewing light box in a dark room and yellow light viewing light box in a dark room. Number of circular shadows observed on the film was recorded. The data were analyzed by two-way ANOVA.Results: The mean number of detected circular shadows was 6.75, 7.5, 7.25 and 7.75 in white light viewing light box in a lit room, white light viewing light box in a dark room, yellow light viewing light box in a lit room and yellow light viewing light box in a dark room, respectively. Although the surrounding illumination had statistically significant effect on the radiographic details (P≤0.03, the light color of the viewing light box had no significant effect on visibility of the radiographic details.Conclusion: White and yellow light of the viewing light box had no significant effect on visibility of the radiographic details but more information was obtained in a dark room.

  11. Evaluation of the styloid process on digital panoramic radiographs

    International Nuclear Information System (INIS)

    More, Chandramani B; Asrani, Mukesh K

    2010-01-01

    The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 – 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. To assess the styloid process on digital panoramic radiographs. The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin

  12. Are reporting radiographers fulfilling the role of advanced practitioner?

    International Nuclear Information System (INIS)

    Milner, R.C.; Snaith, B.

    2017-01-01

    Background: Advanced practice roles are emerging in all disciplines at a rapid pace and reporting radiographers are ideally placed to work at such level. Advanced practitioners should demonstrate expert practice and show progression into three other areas of higher level practice. Most existing literature has focussed on the image interpretation aspect of the role, however there is little evidence that plain film reporting radiographers are undertaking activities beyond image interpretation and fulfilling the role of advanced practitioner. Method: Letters were posted to every acute NHS trust in the UK, inviting reporting radiographers to complete an online survey. Both quantitative and qualitative information was sought regarding demographics and roles supplementary to reporting. Results: A total of 205 responses were analysed; 83.3% of reporting radiographers describe themselves as advanced practitioner, however significantly less are showing progression into the four core functions of higher level practice. A total of 97.0% undertake expert practice, 54.7% have a leadership role, 19.8% provide expert lectures and 71.1% have roles encompassing service development or research, though most of these fall into the service development category. 34.5% felt that they were aware of the differences between extended and advanced practice though much less (9.3%) could correctly articulate the difference. Conclusion: Few individuals are aware of the difference between extended and advanced practice. Though the majority of plain film reporting radiographers identify themselves as advanced practitioners, significantly less evidence all four core functions of higher level practice. The number of individuals undertaking research and providing expert-level education is low. - Highlights: • 83.3% of reporting radiographers describe themselves as advanced practitioners. • Only 56.0% undertake all four core functions of higher level practice. • Only 15.4% of reporting

  13. Factors for lifelong job retention among Swiss radiographers

    International Nuclear Information System (INIS)

    Lehmann, P.; Meystre, N. Richli; Mamboury, N.

    2015-01-01

    In Switzerland, a shortage of radiographers in the three radiology domains, radio-diagnostic, radiotherapy and nuclear medicine, is supposed to increase in the upcoming years. As job satisfaction has been shown to contribute to workplace retention, one purpose of the study was to explore the relationship between workplace retention and duration in the profession with job satisfaction. The study was based on two surveys. The institutional survey was addressed to all chiefs of radiology units in hospitals and ambulatory institutes (340, response rate 48%). All radiographers were asked to complete the individual survey (3000, response rate 25%). Two thirds of radiographers had been employed for five or more years in the same workplace, and nearly half intended to stay for 10 more years. The professional lifespan of radiographers is estimated to be approximately 27 years. 75% expressed their satisfaction with key aspects of professional activity, including the content of the work, autonomy, technology and their relationships with professionals and patients. These factors were not linked to a particular workplace, but to the profession itself. The radiographers build their own propitious work environment, even if salary and recognition by physicians are contributing to their dissatisfaction. The retention in the profession, consolidated by a high level of satisfaction, is an essential feature for a workforce policy. However, active measures for reinforcing retention are still necessary when considering that a lifelong career needs challenges and rewards. Additionally, the retention rate does not provide a guarantee adequacy for the future projected needs in the profession. - Highlights: • Retention in the profession, with a high level of satisfaction, is a major point for a workforce policy. • Job satisfaction of radiographers is not linked to a particular workplace, but to the profession itself. • The professional lifespan of radiographers in Switzerland is

  14. Radiographic evidence of femoroacetabular impingement in athletes with athletic pubalgia.

    Science.gov (United States)

    Economopoulos, Kostas J; Milewski, Matthew D; Hanks, John B; Hart, Joseph M; Diduch, David R

    2014-03-01

    Two of the most common causes of groin pain in athletes are femoroacetabular impingement (FAI) and athletic pubalgia. An association between the 2 is apparent, but the prevalence of radiographic signs of FAI in patients undergoing athletic pubalgia surgery remains unknown. The purpose of this study was to determine the prevalence of radiologic signs of FAI in patients with athletic pubalgia. We hypothesized that patients with athletic pubalgia would have a high prevalence of underlying FAI. Case series. Level 4. A retrospective review of all patients evaluated at our institution with athletic pubalgia who underwent surgical treatment (ie, for sports hernia) from 1999 to 2011 was performed. The radiographs of patients with athletic pubalgia were reviewed for radiographic signs of FAI. Alpha angles were measured using frog-leg lateral radiographs. Pincer lesions were identified by measuring the lateral center-edge angle and identifying the presence of a "crossover" sign on anteroposterior radiographs. Phone follow-up was performed 2 years or more after the initial sports hernia surgery to evaluate recurrent symptoms. Forty-three patients underwent 56 athletic pubalgia surgeries. Radiographic evidence of FAI was identified in at least 1 hip in 37 of 43 patients (86%). Cam lesions were identified in 83.7% of the population; the alpha angle averaged 66.7° ± 17.9° for all hips. Pincer lesions were present in 28% of the hips. Eight patients had recurrent groin pain, 3 patients had revision athletic pubalgia surgery, and 1 had hip arthroscopy. The study demonstrates a high prevalence of radiographic FAI in patients with athletic pubalgia. Underlying FAI may be a cause of continued groin pain after athletic pubalgia surgery. Patients with athletic pubalgia should be evaluated closely for FAI.

  15. Evaluation of the styloid process on digital panoramic radiographs

    Directory of Open Access Journals (Sweden)

    More Chandramani

    2010-01-01

    Full Text Available Background: The styloid process is an anatomical structure, whose clinical importance is not well understood. Proper clinical and radiographic evaluation can detect an elongated styloid process and calcification of the stylohyoid ligament. It has been reported that 2 - 28% of the general population show radiographic evidence of mineralization of a portion of the stylohyoid chain. The elongated styloid process may be symptomatic in many cases. Panoramic radiography is the best imaging modality to view the styloid process bilaterally. Aim: To assess the styloid process on digital panoramic radiographs. Materials and Methods: The study was conducted on 500 digital panoramic radiographs available in the archives of our department as soft copies. These radiographs were taken using a digital panoramic system. The radiographic length of the styloid process was measured on both sides using the measurement toolbars on the accompanying analysis software. For statistical analysis we used the unpaired t test, Chi-square test, and one-way ANOVA test, as necessary. Results: The average length of the left styloid was 25.41 ± 6.32 mm and that of the right styloid was 25.53 ± 6.62 mm. The length of both styloids increased with age and males had longer styloids than females. Elongated styloids were present in 19.4% of the panoramic radiographs. Langlais type I elongated styloids and a partial calcification pattern were more common than others. Conclusion: Panoramic radiography is useful for detection of an elongated styloid process and / or ossification of the stylohyoid ligament in patients with or without symptoms, and helps avoid a misdiagnosis of tonsillar pain or pain of dental, pharyngeal, or muscular origin.

  16. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-09-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing both properties separately are available it is desirable that the method permits the assessment of all the relevant properties together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas radiographic image thicknesses. The use of the constant exposure technique could be used to compare both the sensitometric properties as well as the image quality for different radiographic materials. It consist of exposing different film or paper brands at a chosen, constant mAmin exposure when testing radiographic image quality for different thicknesses of a given material. From the results obtained with the constant exposure technique conclusions are drawn about its applicability as a standard method for assessing radiographic film and paper. (author)

  17. Chest radiographic findings in bronchogenic carcinoma in pakistani population

    International Nuclear Information System (INIS)

    Suliman, M.I.; Ali, B.; Majeed, H.; Qureshi, F.

    2008-01-01

    To observe the common radiographic findings in histologically confirmed cases of bronchogenic carcinoma. This descriptive study comprised of 35 consecutive histopathologically / cytological confirmed cases of bronchogenic carcinoma that were admitted from January 2000 to April 2003 in Bahawal Victoria Hospital Bahawalpur. Plain chest radiographs were obtained in all cases Two radiologists blinded to the cell types were asked to interpret the radiographs. Hilar mass was the major manifestation in 62.8% cases. Chest radiographs showed 7 different types of lesions in four cell varieties in 35 cases, these included hilar mass in 62% cases of squamous cell carcinoma. Cavitation and rib erosion were found exclusively in squamous cell type carcinoma. In small cell carcinomas, hilar Involvement was present in 83.3% cases. Half of large cell carcinomas and one case of adenocarcinoma presented with a peripheral mass. Hilar mass was seen in 50% cases with adenocarcinoma Wide mediastinum was seen only in cases with small cell carcinoma. The chest radiograph findings in bronchogenic carcinoma has more or less a standard patterns which Can help the physician in better suspicion and diagnosis. (author)

  18. Measuring anteversion in the femoral neck from routine radiographs

    International Nuclear Information System (INIS)

    Hermann, K.L.; Egund, N.

    1998-01-01

    Purpose: To describe a new method for measuring femoral neck anteversion (FNA) that requires only one lateral radiograph of the knee in addition to routine radiographs of the hip for evaluation of total hip replacement; and to compare the proposed method with FNA measurement by means of 3D CT. Material and Methods: In 18 femoral specimens, radiographic examinations of the hip and knee, in three different rotational positions, and one CT examination were made, and the measurements of FNA were compared. Similarly, in 38 patients with 40 total hip replacements, measurements form routine radiographic examinations of the hip and knee and from CT examinations were compared. The accuracy and reproducibility of the FNA measurements produced by this proposed method were calculated. Results: Accuracy and reproducibility were 2 and 2 for the proposed method in the femoral specimen study, and accuracy was 4 in the hip patient study. The proposed method had a minor flaw that was caused almost solely by differences in knee size at inward rotation of the femur. Conclusion: FNA measurement can be made from a routine radiographic examination of the hip and a lateral view of the knee. This method achieves an acceptable level of accuracy and reproducibility. (orig.)

  19. Study on application of contrastmeter in radiographic examination, 1

    International Nuclear Information System (INIS)

    Ooka, Kiichi; Hirayama, Kazuo; Senda, Tomio.

    1986-01-01

    As a check on the image quality of radiograph, it is customary to place a Image Quality Indicator, I. Q. I., and a contrastmeter. Although the observation results of I. Q. I. on the radiograph are affected remarkably by the difference amonge individuals, the density difference of contrastmeter dose not depend on it since the radiographic density is measured with densitometer. In order to apply both I. Q. I. and contrastmeter on all material thickness, it is necessary to know the quantitative relationship between the I. Q. I. sensitivity and the density difference in the contrastmeter. The quantitative relationship for aluminium welds are discussed. The value of dennity difference when the I. Q. I. sensitivity is considered is suitable for controlling the image quality of radiograph. For the reason that the value of density difference of contrastmeter is not strongly infuluenced, it is necessary for adopting the value obtained by dividing the density difference by radiographic density. The dimension of contrastmeter for Aluminium welds more over 20 mm in material thickness should be 20 mm in width and 3.0 mm and 4.0 mm in thickness corresponding to the material thickness. (author)

  20. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  1. Variability interexaminer of chronic apical periodontitis diagnostics in panoramic radiographs

    International Nuclear Information System (INIS)

    Montero Aguilar, Mauricio; Zeledon Mayorga, Rodolfo; Ramirez Mora, Tatiana; Monestel Umana, Silvia

    2009-01-01

    The accuracy of radiological diagnosis of Apical Periodontitis (AP) is reported between examiners with differents levels of clinical experience using panoramic radiographs. 1032 teeth in 41 panoramic radiographs have been diagnosed. The evaluation of the x-rays and radiological diagnosis is performed by three independent dentists for AP to each tooth. The teeth have presented without radiological signs of AP in 96.6%. The number of teeth classified with an uncertain diagnosis of AP at the has been inversely proportional to the number of years of experience of the examiner. The examiner A has been used as a reference and compared the diagnoses of other examiners.The percentage agreement for all teeth was 95% for examiner B and 94% for examiner C. Kappa for all has been of 0.44 for examiner B and 0.43 for examiner C. The different categories were analyzed separately, the inferior teeth and the anterior teeth have obtained the best results. The level of clinical experience of the examiner has been indifferent in the diagnosis of AP in panoramic radiographs; however, it is important experience in the number of radiographs extras that will be needed to give a radiological diagnosis definitive. The panoramic radiographs were reliable diagnostic tools for AP. (author) [es

  2. Cost-effectiveness of barium enemas performed by radiographers

    International Nuclear Information System (INIS)

    Brown, Lorraine; Desai, Sharad

    2002-01-01

    AIM: To assess the cost-effectiveness of barium enemas performed by radiographers compared to those performed by consultant radiologists. METHOD: Prospective study of 200 barium enemas carried out by a senior radiographer and a consultant radiologist. The sample was a consecutive sample of adult out-patients over a 3-month period, with no exclusion. The length of time of the enema and the numbers and grades of staff involved in the procedure were recorded. This was translated into staffing costs using the appropriate pay scales. RESULTS: The barium enemas performed by the superintendent radiographer were more cost-effective than those performed by the consultant radiologist (1406 pounds for 100 radiographer-performed barium enemas compared to 1787 pounds for 100 carried out by the consultant radiologist). CONCLUSION: In terms of staffing costs, radiographers performing barium enemas not only liberates radiologist time, it is also a cost-effective method of providing an out-patient barium enema service. Brown, L. and Desai, S. (2002)

  3. General practitioners' willingness to request plain lumbar spine radiographic examinations

    International Nuclear Information System (INIS)

    Ryynaenen, Olli-Pekka; Lehtovirta, Jukka; Soimakallio, Seppo; Takala, Jorma

    2001-01-01

    Objectives: To examine general practitioners' attitudes to plain lumbar spine radiographic examinations. Design: A postal questionnaire consisting of questions on background data and doctors' opinions about plain lumbar spine radiographic examinations, as well as eight vignettes (imaginary patient cases) presenting indications for lumbar radiography, and five vignettes focusing on the doctors' willingness to request lumbar radiography on the basis of patients' age and duration of symptoms. The data were analysed according to the doctor's age, sex, workplace and the medical school of graduation. Setting: Finland. Subjects: Six hundred and fifteen randomly selected physicians working in primary health care (64% of original target group). Results: The vignettes revealed that the use of plain lumbar radiographic examination varied between 26 and 88%. Patient's age and radiation protection were the most prominent factors influencing doctors' decisions to request lumbar radiographies. Only slight differences were observed between the attitudes of male and female doctors, as well as between young and older doctors. Doctors' willingness to request lumbar radiographies increased with the patient's age in most vignettes. The duration of patients' symptoms had a dramatic effect on the doctor's decision: in all vignettes, doctors were more likely to request lumbar radiography when patient's symptoms had exceeded 4 weeks. Conclusions: General practitioners commonly use plain lumbar spine radiographic examinations, despite its limited value in the diagnosis of low back pain. Further consensus and medical education is needed to clarify the indications for plain lumbar radiographic examination

  4. Surgical crown lengthening: a 12-month study - radiographic results

    Directory of Open Access Journals (Sweden)

    Daniela Eleutério Diniz

    2007-08-01

    Full Text Available OBJECTIVE: The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. MATERIAL AND METHODS: Twenty-three periodontally healthy subjects (mean age 32.5 years that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. RESULTS: Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. CONCLUSION: The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest.

  5. Justification of radiographic examinations: What are the key issues?

    Science.gov (United States)

    Vom, Jason; Williams, Imelda

    2017-09-01

    Justification of radiographic examinations is the practice of evaluating requested radiological examinations to assess for clinical merit and appropriateness based on clinical notes and patient information. This implies that justification in radiography requires the evaluation of requested examinations, the justification of exposures being applied and determining whether patients fit the recommended criteria for the procedure. Medico-legal requirements by the professional registration body, the Medical Radiation Practice Board of Australia (MRPBA), identify justification as an advocated and obligatory practice for radiographers. Yet, justification remains an inconsistent practice implemented amongst Australian radiographers. This review aims to identify associated barriers inhibiting the consistent practice of justification and the hesitance by radiographers in practicing justification responsibilities. It also recommends a change in workplace culture which encourages radiographers to accept a more autonomous role that cultivates critical thinking, reflection and research-informed decision making as justification will ultimately benefit patients. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  6. Digital image processing of mandibular trabeculae on radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Ogino, Toshi

    1987-06-01

    The present study was aimed to reveal the texture patterns of the radiographs of the mandibular trabeculae by digital image processing. The 32 cases of normal subjects and the 13 cases of patients with mandibular diseases of ameloblastoma, primordial cysts, squamous cell carcinoma and odontoma were analyzed by their intra-oral radiographs in the right premolar regions. The radiograms were digitized by the use of a drum scanner densitometry method. The input radiographic images were processed by a histogram equalization method. The result are as follows : First, the histogram equalization method enhances the image contrast of the textures. Second, the output images of the textures for normal mandible-trabeculae radiograms are of network pattern in nature. Third, the output images for the patients are characterized by the non-network pattern and replaced by the patterns of the fabric texture, intertwined plants (karakusa-pattern), scattered small masses and amorphous texture. Thus, these results indicates that the present digital image system is expected to be useful for revealing the texture patterns of the radiographs and in the future for the texture analysis of the clinical radiographs to obtain quantitative diagnostic findings.

  7. [The importance of conventional radiographs in the diagnosis of osteosarcoma].

    Science.gov (United States)

    Meyer, S; Reinhard, H; Graf, N; Püschel, W; Ziegler, K; Schneider, G

    2002-01-01

    We report about a 12-year-old boy with a history of recurrent patella luxation. Due to persistent pain in the distal left femur a MRI examination was performed in another hospital which suggested a malignant bone tumor. Without validation of the MRI findings by conventional radiographs bone biopsy was performed. Histopathological examination yielded the diagnosis of a chondroblastic osteosarcoma. Before initiating polychemotherapy, plain radiographs for the first time, a nuclear imaging study and an additional MRI examination were performed in our hospital. The results of these studies made the diagnosis of an osteosarcoma unlikely. In particular, plain radiographs did not show any osseous lesion which was characteristic of an osteosarcoma. To establish a definite diagnosis biopsy was repeated with resection of the bone area which showed suspicious changes in MRI studies. An osteosarcoma was ruled out by histopathological examination. The pathologic changes detected in MRI were rated as bone bruise on plain radiographs and seemed to be of traumatic origin. Our case report emphasises the importance of conventional radiographs in establishing the diagnosis of an osteoarcoma respectively bone tumors and tumor-like lesions in general. They still remain the mainstay in diagnosing bone forming tumors. MRI imaging studies may show changes which mimick solid lesions but in deed can be of traumatic origin. Without informing the pathologist about the exact origin of the specimen, histopathological examination may lead to the misdiagnosis of a chondroblastic osteosarcoma if specimen, like in this case report, represents epiphyseal tissue showing cartilaginous areas with reactive bone formation.

  8. Neutron radiographic findings in light water reactor fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1979-06-01

    The assessment of neutron radiographs of nuclear fuel elements can be much easier, faster and simpler if reference can be made to typical defects, which can be revealed by neutron radiography. In other fields of industrial radiography collections of reference radiographs, showing typical defects in welding, or casting have been completed and published long ago. Since 1974 neutron radiography is routinely used at Risoe National Laboratory, Denmark, for the quality and performance control of nuclear fuel. About 2000 neutron radiographs were taken, mainly during the post irradiation examination of light water reactor fuel. During assessment of neutron radiographs some typical defects of the fuel were found and it was felt that a classification of such defects will help to speed up the assessment procedure. Therefore an attempt was made to establish such a classification, which is currently used at Risoe now. This classification is presented in this atlas, which contains 36 neutron radiographs reproduced on film (in original size) and on paper (twice enlarged). (author)

  9. Radiographic features of paediatric pneumocystis pneumonia - a historical perspective

    International Nuclear Information System (INIS)

    Pitcher, R.D.; Zar, H.J.

    2008-01-01

    Aim: To determine differences between the plain radiographic features of paediatric pneumocystis pneumonia (PCP) recorded before the emergence of human immunodeficiency virus (HIV) in 1982 and those documented in the HIV era. To establish differences in the radiographic features of PCP documented in HIV-infected children in developed and developing countries. Method: A Medline search of articles was conducted from 1950 to 2006, using the terms 'pneumocystis pneumonia in children' and 'chest radiographic features' or 'bilateral opacification' or 'lobar consolidation' or 'asymmetrical opacification' or 'pneumatocoeles' or 'cavities' or 'pneumothorax' or 'pneumomediastinum' or 'pleural effusion' or 'mediastinal adenopathy' or 'nodules' or 'normal chest radiography'. Appropriate articles were retrieved, radiological data extracted, reference lists examined and hand searches of referenced articles conducted. Results: Diffuse bilateral 'ground-glass' or alveolar pulmonary opacification, which may show some asymmetry, has been consistently documented as the commonest radiographic finding in childhood PCP throughout the period under review. The less common radiological features of PCP in children are similar to those in adults. In developed countries, PCP-related pulmonary air cysts have been reported at an earlier age in HIV-infected children, compared with uninfected children. PCP-related air cysts, pneumothorax, and pneumomediastinum have been reported in children in developed but not in developing countries. Conclusion: The radiological features of paediatric PCP documented before the HIV epidemic are similar to those recorded in the HIV era. Further study of the determinants of the uncommon radiographic features in children is warranted

  10. Construction of a homogeneous phantom for radiographic image standardization

    International Nuclear Information System (INIS)

    Pina, Diana Rodrigues de

    1996-01-01

    The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow the obtention of k Vp and m As combinations, to produce radiographic images of good quality, and the reproduction of these combinations to any conventional equipment of diagnostic X-rays. Also presented are the comparison of the doses imparted by these combinations and those used in routine of the Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto's radiodiagnosis service. (author)

  11. Presence of bias in radiographer plain film reading performance studies

    International Nuclear Information System (INIS)

    Brealey, S.; Scally, A.J.; Thomas, N.B.

    2002-01-01

    Purpose To raise awareness of the frequency of bias that can affect the quality of radiographer plain film reading performance studies. Methods Studies that assessed radiographer(s) plain film reading performance were located by searching electronic databases and grey literature, hand-searching journals, personal communication and scanning reference lists. Thirty studies were judged eligible from all data sources. Results A one-way analysis of variance (ANOVA) demonstrates no statistically significant difference (P=0.25) in the mean proportion of biases present from diagnostic accuracy (0.37), performance (0.42) and outcome (0.44) study designs. Pearson's correlation coefficient showed no statistically significant linear association between the proportion of biases present for the three different study designs and the year that the study was performed. The frequency of biases in film and observer selection and application of the reference standard was quite low. In contrast, many biases were present concerning independence of film reporting and comparison of reports for concordance. Conclusions The findings indicate variation in the presence of bias in radiographer plain film reading performance studies. The careful consideration of bias is an essential component of study quality and hence the validity of the evidence-base used to underpin radiographic reporting policy

  12. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  13. Radiographic findings of femoroacetabular impingement in National Football League Combine athletes undergoing radiographs for previous hip or groin pain.

    Science.gov (United States)

    Nepple, Jeffrey J; Brophy, Robert H; Matava, Matthew J; Wright, Rick W; Clohisy, John C

    2012-10-01

    The purpose of this study was to investigate the prevalence of radiographic findings of femoroacetabular impingement (FAI) in elite football players with a history of hip pain or groin injury who underwent radiographs. We performed a retrospective review of athletes undergoing hip radiography at the National Football League Combine from 2007 to 2009. Radiographs were obtained in athletes with a history of hip pain or injury. Anteroposterior pelvis and frog-lateral radiographs were obtained in 123 hips (107 players) that met our inclusion criteria. Radiographic indicators of cam-type FAI (alpha angle, head-neck offset ratio) and pincer-type FAI (acetabular retroversion, center-edge angle, acetabular inclination) were recorded. Findings were correlated with clinical factors (previous groin/hip pain, position, race, and body mass index). The most common previous injuries included groin strain (n = 57) and sports hernia/abdominal strain (n = 21). Markers of cam- and/or pincer-type FAI were present in 94.3% of hips (116 of 123). Radiographic evidence of combined cam- and pincer-type FAI was the most common (61.8%, 76 hips), whereas isolated cam-type FAI (9.8%, 12 hips) and pincer-type FAI (22.8%, 28 hips) were less common. The most common deformities included acetabular retroversion (71.5%) and an abnormal alpha angle (61.8%). A body mass index greater than 35 was associated with the presence of global overcoverage (46.2% v 17.3%, P = .025). Radiographic indicators of FAI are very common among athletes evaluated at the National Football League Scouting Combine subjected to radiographic examination for the clinical suspicion of hip disease. Elite football athletes with significant or recurrent pain about the hip should be evaluated clinically and radiographically for FAI, because pain from FAI may be falsely attributed to or may be present in addition to other disorders. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America

  14. Educational and experiential effects on radiographers' radiation safety behavior

    International Nuclear Information System (INIS)

    Tilson, E.R.

    1982-01-01

    Forty-four radiographers from 11 hospitals in Northern California were observed for radiation safety behaviors in six categories. A multiple regression analysis was performed to determine if there was a significant relationship between the six radiation safety behaviors and the radiographer's age, sex, type of professional training, years since completion of professional training, years of professional practice, time of day, and exposure frequency. The multiple regression analysis showed that there was a significant relationship between use of gonadal shielding and years since completion of professional training, years of professional practice, type of training, and age. The multiple regression analysis also showed that the number of repeated films due to technical error was significantly related to the type of professional training a radiographer received

  15. The effects of PACS on radiographer's work practice

    International Nuclear Information System (INIS)

    Larsson, W.; Aspelin, P.; Bergquist, M.; Hillergard, K.; Jacobsson, B.; Lindskoeld, L.; Wallberg, J.; Lundberg, N.

    2007-01-01

    This paper identifies and analyses the effects of picture archiving and communication systems (PACS) on radiographers' work practice. It shows that the introduction of PACS did not simply entail the transfer of data and information from the analogue world to the digital world, but it also led to the introduction of new ways of communicating, and new activities and responsibilities on the part of radiography staff. Radiographers are called upon to work increasingly independently, and individual practitioners require higher levels of professional expertise. In all, this paper demonstrates that new technical solutions sometimes lead to substantial changes in responsibilities in work. In this example, the radiographers' work practice has become more highly scientific and they are enjoying a higher level of prestige

  16. Quality of the radiographic image in paper radiography

    International Nuclear Information System (INIS)

    Domanus, J.C.; El Fouly, H.M.

    1981-09-01

    The quality of the radiographic image was investigated by the use of standard ISO wire Image Quality Indicators and ASTM Penetrameters. 10, 20, and 30 mm thick welds on alumunium and steel plates were radiographed using X-ray machines with voltages from 35 to 300 kV. Agfa-Gevaert Structurix IC paper with Structurix IC screens Type II as well as Kodak Industrex 600 and 620 and Rapid 700 paper with Fl and F2 screens were used throughout the investigation. The results reached for radiographic paper were compared with those for a fast X-ray film (Kodak Industrex D). The results of the investigation were presented at the International Conference Joining of Metals JOM-1 in Elsinore, Denmark (9-12.8.1981) and at the Second European Conference on Non-Destructive Testing in Vienna (14-16.9.1981). The texts of both papers are reproduced in this report. (author)

  17. Observations of radiographer communication: An exploratory study using Transactional Analysis

    International Nuclear Information System (INIS)

    Booth, Lisa A.; Manning, David J.

    2006-01-01

    Purpose: Communication in medical imaging is a neglected area of research, despite the necessity for good communication if optimum diagnostic images are to be achieved. Methods: The present study has investigated the styles of communication used in medical imaging, using an approach known as Transactional Analysis. This approach has been demonstrated previously as having reliability and validity, using observations and supporting interviews with medical imaging staff, along with inter-rater observations of radiographer-patient interactions. Results: The results indicate that Transactional Analysis can be used effectively for identifying and naming interaction events in diagnostic radiography, with diagnostic radiographers using five styles of communication. Conclusion: Radiographers tend to use Parental styles of communicating; these styles are commonly associated with a practitioner-centred approach to dealing with patients which often result in non-adherence

  18. Pacman dysplasia: a lethal skeletal dysplasia with variable radiographic features

    Energy Technology Data Exchange (ETDEWEB)

    Miller, S.F. [Dept. of Radiology, Children' s Hospital of the King' s Daughters, Norfolk (United States); Proud, V.K. [Dept. of Genetics, Children' s Hospital of the King' s Daughters, Norfolk (United States); Werner, A.L. [Dept. of Pathology, Children' s Hospital of the King' s Daughters, Norfolk (United States); Field, F.M.; Wilcox, W.F.; Lachman, R.S.; Rimoin, D.L. [International Skeletal Dysplasia Registry, Cedars-Sinai Medical Center, Los Angeles (United States)

    2003-04-01

    Background: Punctate or stippled cartilaginous calcifications are associated with many conditions, including chromosomal, infectious, endocrine, and teratogenic etiologies. Some of these conditions are clinically mild, while others are lethal. Accurate diagnosis can prove instrumental in clinical management and in genetic counseling. Objective: To describe the diagnostic radiographic features seen in Pacman dysplasia, a distinct autosomal recessive, lethal skeletal dysplasia. Materials and methods: We present the fourth reported case of Pacman dysplasia and compare the findings seen in our patient with the three previously described patients. Results: Invariable and variable radiographic findings were seen in all four cases of histologically proven Pacman dysplasia. Conclusion: Pacman dysplasia presents both constant and variable diagnostic radiographic features. (orig.)

  19. Quantitative radiographic analysis of fiber reinforced polymer composites.

    Science.gov (United States)

    Baidya, K P; Ramakrishna, S; Rahman, M; Ritchie, A

    2001-01-01

    X-ray radiographic examination of the bone fracture healing process is a widely used method in the treatment and management of patients. Medical devices made of metallic alloys reportedly produce considerable artifacts that make the interpretation of radiographs difficult. Fiber reinforced polymer composite materials have been proposed to replace metallic alloys in certain medical devices because of their radiolucency, light weight, and tailorable mechanical properties. The primary objective of this paper is to provide a comparable radiographic analysis of different fiber reinforced polymer composites that are considered suitable for biomedical applications. Composite materials investigated consist of glass, aramid (Kevlar-29), and carbon reinforcement fibers, and epoxy and polyether-ether-ketone (PEEK) matrices. The total mass attenuation coefficient of each material was measured using clinical X-rays (50 kev). The carbon fiber reinforced composites were found to be more radiolucent than the glass and kevlar fiber reinforced composites.

  20. Imaging of juvenile spondyloarthritis. Part I: Classifications and radiographs

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are manifested mainly by symptoms of peripheral arthritis and enthesitis. By contrast with adults, children rarely present with sacroiliitis and spondylitis. Imaging and laboratory tests allow early diagnosis and treatment. Conventional radiographs visualize late inflammatory lesions and post-inflammatory complications. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presents classifications of juvenile spondyloarthropathies and discusses their radiographic presentation. Typical radiographic features of individual types of juvenile spondyloarthritis are listed (including ankylosing spondylitis, juvenile psoriatic arthritis, reactive arthritis and arthritis in the course of inflammatory bowel diseases. The second part will describe changes visible on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance imaging also visualizes early inflammatory changes in the axial skeleton and subchondral bone marrow edema, which is considered an early sign of inflammation.

  1. Radiographic changes in rhesus macaques affected by scurvy

    International Nuclear Information System (INIS)

    Morgan, J.P.; Eisele, P.H.

    1992-01-01

    Spontaneous vitamin C deficiency, or scurvy, was recognized in juvenile rhesus monkeys maintained in a research center as a result of being fed a commercial diet for 2 to 3 months with low levels of vitamin C. Most severely affected animals (13) were radiographed repeatedly up to day 300 following detection of the disease. Early radiographic changes consisted of widened, lucent metaphyses with lateral flaring and radiopaque metaphyseal lines at the junction of the metaphyses and physes. Physeal slippage was noted commonly. Following institution of vitamin C therapy, calcification of subperiosteal hemorrhage occurred in the metaphyseal regions. Metaphyses and physes returned to normal radiographic appearance within 15 to 30 days. Initially, the subperiosteal hemorrhage progressed and a longer time was required for solution of the calcified hematomas. The macaques improved clinically and were released from the hospital when fractures were stable at 4-5 weeks after admission. Of the 13 macaques studied, all but one returned as normal members of the colony

  2. Comparisons of NIF convergent ablation simulations with radiograph data.

    Science.gov (United States)

    Olson, R E; Hicks, D G; Meezan, N B; Koch, J A; Landen, O L

    2012-10-01

    A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.

  3. Subglottic cysts and asymmetrical subglottic narrowing on neck radiograph

    International Nuclear Information System (INIS)

    Holinger, L.D.; Torium, D.M.; Anandappa, E.C.

    1988-01-01

    The congenital subglottic hemangioma typically appears as an asymmetric subglottic narrowing or mass on frontal neck radiograph. Therefore, soft tissue neck radiography has been advocated as a definitive non-operative approach for diagnosing these lesions. However, we have noted similar asymmetric subglottic narrowing in patients with acquired subglottic cysts. These retention cysts occur following long-term intubation in the neonate. The mechanism probably involves subglottic fibrosis which obstructs glands with subsequent cyst formation. Acquired subglottic cysts typically appear as an asymmetric narrowing on frontal or lateral soft tissue neck radiographs. These lesions may produce airway compromise but are effectively treated by forceps or laser removal. Acquired subglottic cysts must be included in the differential diagnosis of asymmetric subglottic narrowing. The definitive diagnosis is made by direct laryngoscopy, not soft tissue neck radiograph. (orig.)

  4. Defects quantization in industrial radiographs by image processing

    International Nuclear Information System (INIS)

    Briand, F.Y.; Brillault, B.; Philipp, S.

    1988-01-01

    This paper refers to the industrial application of image processing using Non Destructive Testing by radiography. The various problems involved by the conception of a numerical tool are described. This tool intends to help radiograph experts to quantify defects and to follow up their evolution, using numerical techniques. The sequences of processings that achieve defect segmentation and quantization are detailed. They are based on the thorough knowledge of radiographs formation techniques. The process uses various methods of image analysis, including textural analysis and morphological mathematics. The interface between the final product and users will occur in an explicit language, using the terms of radiographic expertise without showing any processing details. The problem is thoroughly described: image formation, digitization, processings fitted to flaw morphology and finally product structure in progress. 12 refs [fr

  5. Radiographic imaging for Ilizarov limb lengthening in children

    International Nuclear Information System (INIS)

    Blane, C.E.; DiPietro, M.A.; Herzenberg, J.E.

    1991-01-01

    The Ilizarov method for limb lengthening is rapidly gaining popularity in North America. Use of this new technique has necessitated modifications in radiographic protocol. Initial imaging problems gained from our experience with twenty children are detailed including accurate centering for the plain films, correcting for magnification to accurately measure the distraction gap and the expected radiographic appearance of the regenerate bone. Ultrasonography has potential value in accurately measuring the distraction gap and in imaging the new bone prior to radiographic appearance. Since overly fast distraction inhibits bone formation and overly slow distraction leads to premature consolidation, ultrasound may serve a useful role in the qualitative evaluation of new bone formation in Ilizarov limb lengthening, enabling the orthopedic surgeon to tailor the distraction rate to the particular child. (orig.)

  6. Early diagnosis of atherosclerosis with panoramic radiographs: a review

    Directory of Open Access Journals (Sweden)

    Daiane Landim Borba

    Full Text Available Abstract Carotid artery disease has been linked with cerebral vascular accident, also known as stroke, cerebral hemorrhage, or cerebral ischemia. It is caused by narrowing or obstruction of arteries in the neck (the carotid arteries that are responsible for transporting blood from the aorta to the brain. Panoramic radiographs are used in dentistry to show both dental arches as a supplement to the clinical dental examination. The objective of this study is to highlight the importance of panoramic radiographs for diagnosis of arterial disease, by means of a bibliographic review. The PubMed database was searched using the keywords “atherosclerosis” and “panoramic”, with the filters “last 5 years” and “humans”. Twenty articles were identified, six of which were chosen for this study because they were open access. The review concluded that panoramic radiographs enable early diagnosis of carotid artery calcification, resulting in earlier interventions, and offer an accessible cost.

  7. The radiographic appearance of primary liver neoplasia in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Evans, S. M.

    1987-11-15

    The signalment, anamnesis, and histopathologic, gross pathologic, and radiographic findings in 22 dogs with nonvascular, nonhematopoletic primary liver tumors were reviewed. The tumor types represented were hepatoma (8), bile duct cystadenoma (1), hepatocellular carcinoma (5), and cholangiocellular carcinoma (8). The dogs averaged 11.1 years of age. Females were predisposed to cholangiocellular carcinoma. The most common presenting clinical signs were general malaise, anorexia, PU/PD, vomiting, and seizures. Tumors ranged in size from diffuse 0.5-1 cm nodules to an 18-cm solitary mass and were located in any of the liver lobes. Four of the five diffuse tumors were cholangiocellular carcinomas. The most common radiographic appearance for any type of liver tumor was a right cranial abdominal mass causing caudal and left gastric displacement. In 54.5% of the dogs, radiographic evidence of intraperitoneal disease was identified. Nodular interstitial pulmonary masses were seen in 3 of the 22 dogs.

  8. The radiographic appearance of primary liver neoplasia in dogs

    International Nuclear Information System (INIS)

    Evans, S.M.

    1987-01-01

    The signalment, anamnesis, and histopathologic, gross pathologic, and radiographic findings in 22 dogs with nonvascular, nonhematopoletic primary liver tumors were reviewed. The tumor types represented were hepatoma (8), bile duct cystadenoma (1), hepatocellular carcinoma (5), and cholangiocellular carcinoma (8). The dogs averaged 11.1 years of age. Females were predisposed to cholangiocellular carcinoma. The most common presenting clinical signs were general malaise, anorexia, PU/PD, vomiting, and seizures. Tumors ranged in size from diffuse 0.5-1 cm nodules to an 18-cm solitary mass and were located in any of the liver lobes. Four of the five diffuse tumors were cholangiocellular carcinomas. The most common radiographic appearance for any type of liver tumor was a right cranial abdominal mass causing caudal and left gastric displacement. In 54.5% of the dogs, radiographic evidence of intraperitoneal disease was identified. Nodular interstitial pulmonary masses were seen in 3 of the 22 dogs

  9. Cauda equina syndrome in the dog: radiographic evaluation

    International Nuclear Information System (INIS)

    Morgan, J.P.; Bailey, C.S.

    1990-01-01

    Dogs with clinical signs typical of cauda equina syndrome require careful evaluation to determine the cause of the disease as this strongly influences choice of treatment. Possible aetiologies include congenital or developmental, inflammatory, traumatic, neoplastic, and degenerative lesions that may involve vertebrae, vertebral joints, intervertebral discs, spinal cord, spinal nerves, or meninges. It must be determined whether clinical signs are due to musculoskeletal or neurological disease before performing special radiographic procedures. Non-contrast radiography permits false-positive diagnosis of obvious degenerative changes involving the L-S disc that may be without clinical signs or permits a false-negative diagnosis due to the failure to appreciate soft tissue lesions not seen radiographically. Special radiographic techniques are recommended and include: (1) stress radiography, (2) discography, and (3) epidural myelography. Evaluation of the results of these studies assists in determining the cause of the cauda equina syndrome and the type of therapy required

  10. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  11. Radiographers as doctors: A profile of UK doctoral achievement

    International Nuclear Information System (INIS)

    Snaith, B.; Harris, M.A.; Harris, R.

    2016-01-01

    Introduction: Radiography aspires to be a research active profession, but there is limited information regarding the number of individuals with, or studying for, a doctoral award. This study aims to profile UK doctoral radiographers; including their chosen award, approach and employment status. Method: This was a prospective cohort study utilising an electronic survey. No formal database of doctoral radiographers existed therefore a snowball sampling method was adopted. The study sample was radiographers (diagnostic and therapeutic) based in the UK who were registered with the Health and Care Professions Council (HCPC) and who held, or were studying for, a doctoral award. Results: A total of 90 unique responses were received within the timescale. The respondents comprised 58 females (64.4%) and the majority were diagnostic radiographers (n = 71/90; 78.9%). The traditional PhD was the most common award, although increasing numbers were pursuing Education or Professional Doctorates. An overall increase in doctoral studies is observed over time, but was greatest amongst those working in academic institutions, with 63.3% of respondents (n = 57/90) working solely within a university, and a further 10% employed in a clinical–academic role (n = 9/90). Conclusion: This study has demonstrated that radiography is emerging as a research active profession, with increasing numbers of radiographers engaged in study at a doctoral level. This should provide a platform for the future development of academic and clinical research. - Highlights: • 90 radiographers were identified as holding, or studying for, a doctoral award. • The PhD is the most common award. • EdD and professional doctorates are increasing in popularity. • Academic staff were more likely to pursue such research training.

  12. Poor Utility of Gonadal Shielding for Pediatric Pelvic Radiographs.

    Science.gov (United States)

    Lee, Mark C; Lloyd, Jessica; Solomito, Matthew J

    2017-07-01

    Plain pelvic radiographs are commonly used for a variety of pediatric orthopedic disorders. Lead shielding is typically placed over the gonads to minimize radiation exposure to these sensitive tissues. However, misplaced shielding can sabotage efforts to protect patients from excessive radiation exposure either by not covering radiosensitive tissues or by obscuring anatomic areas of interest, prompting repeat radiographic examinations. The goal of this study was to determine the incidence of misplaced shielding for pelvic radiographs obtained for pediatric orthopedic evaluation. Children 8 to 16 years old who had an anteroposterior or frog lateral pelvic radiograph between 2008 and 2014 were included. A total of 3400 patients met the inclusion criteria, and 84 boys and 84 girls were randomly selected for review. For both boys and girls, the percentage of incorrectly positioned or missing shields was calculated. Chi-square testing was used to compare the frequency of missing or incorrectly placed shields between sexes and age groups. Pelvic shields were misplaced in 49% of anteroposterior and 63% of frog lateral radiographs. Shielding was misplaced more frequently for girls than for boys on frog lateral radiographs (76% vs 51%; P<.05). Pelvic bony landmarks were often obscured by pelvic shielding, with a frequency of 7% to 43%, depending on the specific landmark. The femoral head and acetabulum were obscured by shielding in up to 2% of all images. The findings suggest that accepted pelvic shielding protocols are ineffective. Consideration should be given to alternative protocols or abandonment of this practice. [Orthopedics. 2017; 40(4):e623-e627.]. Copyright 2017, SLACK Incorporated.

  13. Radiographic follow-up study of Little Leaguer's shoulder

    International Nuclear Information System (INIS)

    Kanematsu, Yoshiji; Iwase, Takenobu; Matsuura, Tetsuya; Suzue, Naoto; Sairyo, Koichi; Kashiwaguchi, Shinji; Iwame, Toshiyuki

    2015-01-01

    Little Leaguer's shoulder is a syndrome involving the proximal humeral epiphyseal plate. Conservative treatment usually resolves the symptoms. However, there are no reports of a radiographic follow-up study of this disease. The purpose of this study was to show the radiographic healing process of Little Leaguer's shoulder. A total of 19 male baseball players diagnosed as having Little Leaguer's shoulder were retrospectively evaluated. The mean age at first presentation was 12.7 years. External rotation anteroposterior radiographs of the shoulder were taken. All patients were treated with rest from throwing, and no throwing was recommended until remodeling was confirmed. Follow-up radiographs were taken at 1-month intervals to assess healing. All patients were observed until healing was confirmed radiographically, after which they returned to baseball. The mean follow-up period was 8.5 months. In addition to radiography, patients were asked whether they had any symptoms and whether they had been able to return to baseball. At the first examination, radiographs showed a wider epiphyseal plate of the throwing side compared with the asymptomatic contralateral shoulder. Healing was observed in all cases. Healing occurred first along the medial side and was then extended laterally. The mean time required for healing was 4.7 months. All patients were able to return to playing baseball at their pre-injury level of play and were asymptomatic when examined at the final follow-up. The healing process of Little Leaguer's shoulder advanced from medial to lateral, and healing was achieved about 5 months after initial examination. (orig.)

  14. Reliability and relationship of radiographic measurements in hallux valgus.

    Science.gov (United States)

    Lee, Kyoung Min; Ahn, Soyeon; Chung, Chin Youb; Sung, Ki Hyuk; Park, Moon Seok

    2012-09-01

    Although various radiographic measurements have been developed and used for evaluating hallux valgus, not all are universally believed to be necessary and their relationships have not been clearly established. Determining which are related could provide some insight into which might be useful and which would not. We investigated the reliability of eight radiographic measurements used to evaluate hallux valgus, and determined which were correlated and which predicted the hallux valgus angle. We determined eight radiographic indices for 732 patients (mean age, 51 years; SD, 17 years; 107 males and 625 females) with hallux valgus: hallux valgus angle, intermetatarsal angle, hallux interphalangeal angle, distal metatarsal articular angle, proximal phalangeal articular angle, simplified metatarsus adductus angle, first metatarsal protrusion distance, and sesamoid rotation angle. Intraobserver and interobserver reliabilities of each radiographic measurement were analyzed on 36 feet from 36 randomly selected patients. Correlations among the radiographic measurements were analyzed. Radiographic measurements predicting hallux valgus angle were evaluated using multiple regression analysis. Hallux valgus angle had the highest reliability, whereas the distal metatarsal articular angle and simplified metatarsus adductus angle had the lowest. Distal metatarsal articular angle, intermetatarsal angle, and sesamoid rotation angle had the highest correlations with hallux valgus angle. Distal metatarsal articular angle correlated with sesamoid rotation angle. The intermetatarsal angle, interphalangeal angle, distal metatarsal articular angle, first metatarsal protrusion distance, sesamoid rotation angle, and metatarsus adductus angle predicted the hallux valgus angle. We suggest using hallux valgus angle, intermetatarsal angle, interphalangeal angle, sesamoid rotation angle, and first metatarsal protrusion distance considering their reliability and prediction of the deformity.

  15. Radiographic analysis of the course of Legionella pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J. (Dalhousie Univ., Halifax, Nova Scotia (Canada))

    1983-06-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients.

  16. Radiographic techniques adaptation for any conventional X-ray equipment

    International Nuclear Information System (INIS)

    Pina, Diana R.; Ghilardi Netto, Thomaz; Martinez, Alexandre S.; Duarte, Sergio B.; Trad, Clovis S.; Brochi, Marco Aurelio C.

    2001-01-01

    In order to obtain a better risk-benefice relation in diagnostic radiology it turns out to be essential the control and optimization of the radiographic techniques used to reduce the absorbed doses until its minimum, keeping or adjusting the diagnostic image at any X-ray equipment. The present work deals with the standardization of radiographic techniques of chest, skull and pelvis, which is more suitable for obtaining a safe diagnostic with smaller doses, for a standard patient, at any conventional X-ray equipment. (author)

  17. Sensitometric properties and image quality of radiographic film and paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1985-01-01

    When using X-ray film or radiographic paper for industrial applications one is interested in knowing not only their sensitometric properties (such as speed and contrast) but also the image quality obtainable with a particular brand of film or paper. Although standard methods for testing sensitometric properties and image quality separately are available, it is desirable to find a method by the use of which all the relevant properties could be tested together. The sensitometric properties are usually determined at constant kilovoltage and filtration at the X-ray tube, whereas the radiographic image quality is tested at different kilovoltages and for different material thicknesses

  18. Collagenase chemonucleolysis: a long term radiographic study in normal dogs

    International Nuclear Information System (INIS)

    Atilola, M.A.O.; Cockshutt, J.R.; Mclaughlin, R.; Cochrane, S.M.; Pennock, P.W.

    1993-01-01

    Five clinically normal five year old dogs were used in this study. From a randomized table intervertebral discs were each injected with either collagenase or calcium chloride diluent. The surgically exposed cervical discs were injected with 50 units whereas thoracic and lumbar discs were injected under fluoroscopic guidance with 100 units of the enzyme. Postinjection radiographs revealed significant (p ltoreq .05) disc space narrowing in enzyme injected discs. The cervical discs had the highest frequency of radiographic narrowing (87%) followed by the thoracic (70%) and lumbar (53%) discs. Spondylosis deformans developed at the sites of cervical enzyme injections. None of the dogs had neurologic abnormalities one year postinjection

  19. Eric Woods - A lone radiographer at the Normandy landings

    International Nuclear Information System (INIS)

    Barrett, Jean; Ferris, Christine

    2009-01-01

    Although much of the activity around D-day is recorded many of the support services such as radiography do not feature. This account of a radiographer at the Normandy landings gives an insight into the everyday work of a lone radiographer in the Armed Forces in the 1940s. This work is the product of an oral history taken by Jean Barrett in accordance with the acknowledged ethical requirements of oral history. Eric Wood has given his permission for the publication of his stories. The work was presented at the conference for the British Society for the History of Radiology 2008 (Sheffield).

  20. Quantitative analysis of real-time radiographic systems

    International Nuclear Information System (INIS)

    Barker, M.D.; Condon, P.E.; Barry, R.C.; Betz, R.A.; Klynn, L.M.

    1988-01-01

    A method was developed which yields quantitative information on the spatial resolution, contrast sensitivity, image noise, and focal spot size from real time radiographic images. The method uses simple image quality indicators and computer programs which make it possible to readily obtain quantitative performance measurements of single or multiple radiographic systems. It was used for x-ray and optical images to determine which component of the system was not operating up to standard. Focal spot size was monitored by imaging a bar pattern. This paper constitutes the second progress report on the development of the camera and radiation image quality indicators

  1. Coke detection in furnaces tubes by radiographic examination

    International Nuclear Information System (INIS)

    Santos, I.S. dos

    1987-01-01

    The coke detection technique by radiographic examinations allows to quantify the coke in furnace coils of Petroleum refineries and petrochemical industries. The paper describes how was determined the radiographic parameters, the wall apparent thickness calculation, the distance source-film, the position of the source and films, the chosen of films and the calculation of exposure time, aiming to obtain high producticity and good quality image. This technique is being used and improved for more than two years with good results. (E.G.) [pt

  2. Theoretical analysis of radiographic images by nonstationary Poisson processes

    International Nuclear Information System (INIS)

    Tanaka, Kazuo; Uchida, Suguru; Yamada, Isao.

    1980-01-01

    This paper deals with the noise analysis of radiographic images obtained in the usual fluorescent screen-film system. The theory of nonstationary Poisson processes is applied to the analysis of the radiographic images containing the object information. The ensemble averages, the autocorrelation functions, and the Wiener spectrum densities of the light-energy distribution at the fluorescent screen and of the film optical-density distribution are obtained. The detection characteristics of the system are evaluated theoretically. Numerical examples one-dimensional image are shown and the results are compared with those obtained under the assumption that the object image is related to the background noise by the additive process. (author)

  3. Application of artificial neural network in radiographic diagnosis

    International Nuclear Information System (INIS)

    Piraino, D.; Amartur, S.; Richmond, B.; Schils, J.; Belhobek, G.

    1990-01-01

    This paper reports on an artificial neural network trained to rate the likelihood of different bone neoplasms when given a standard description of a radiograph. A three-layer back propagation algorithm was trained with descriptions of examples of bone neoplasms obtained from standard radiographic textbooks. Fifteen bone neoplasms obtained from clinical material were used as unknowns to test the trained artificial neural network. The artificial neural network correctly rated the pathologic diagnosis as the most likely diagnosis in 10 of the 15 unknown cases

  4. Eric Woods - A lone radiographer at the Normandy landings

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Jean [British Society for the History of Radiology (United Kingdom); Ferris, Christine [International Development Facilitator, Robert Winston Building, Faculty of Health and Wellbeing, Sheffield Hallam University, Sheffield S10 2BP (United Kingdom)], E-mail: c.m.ferris@shu.ac.uk

    2009-12-15

    Although much of the activity around D-day is recorded many of the support services such as radiography do not feature. This account of a radiographer at the Normandy landings gives an insight into the everyday work of a lone radiographer in the Armed Forces in the 1940s. This work is the product of an oral history taken by Jean Barrett in accordance with the acknowledged ethical requirements of oral history. Eric Wood has given his permission for the publication of his stories. The work was presented at the conference for the British Society for the History of Radiology 2008 (Sheffield)

  5. Radiographic analysis of the course of Legionella pneumonia

    International Nuclear Information System (INIS)

    Lo, C.D.; MacKeen, A.D.; Campbell, D.R.; Fraser, D.B.; Marrie, T.J.

    1983-01-01

    The radiographic findings in the acute phase of Legionella pneumonia are generally non-specific and have been previously documented. A retrospective assessment of 12 patients with this bacterial pneumonia revealed that resolution of the radiographic findings was prolonged in five. The predominant feature in such patients is the transient finding of interstitial consolidation following the air-space consolidation, not unlike that of Mycoplasma or viral pneumonia. Eventual return to normal was evident in three patients and residual parenchymal fibrosis was noted in two patients

  6. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  7. Clinical history and physical examination skills - A requirement for radiographers?

    International Nuclear Information System (INIS)

    Snaith, Beverly A.; Lancaster, Anne

    2008-01-01

    Radiographer's roles have evolved with their scope broadening over the last 20 years culminating in the development of advanced and consultant posts. Yet one development has not been embraced, despite being inherent in medicine and a common extension of nurse and other allied health professionals' roles, is that of clinical assessment. This article explores the evolving role of the radiographer and discusses whether this should include skills in clinical history taking and physical examination. Issues for education and development will be addressed together with examples of current and potential roles

  8. Software development for the management of cephalometric radiographic data

    Energy Technology Data Exchange (ETDEWEB)

    BeGole, E A [Illinois Univ., Chicago (USA). Medical Center

    1980-04-01

    This paper presents the details and logic of a set of three IBM System 370 Assembler Language programs designed to manage a data bank, of ever increasing magnitude, which contains coordinate data obtained from cephalometric radiographs. The data from the radiographs, and consequently, the programs, are primarily intended for use by the orthodontist who is engaged in clinical research, and are especially useful in studies related to changes within the facial and dental complexes which occur as a result of growth and orthodontic treatment.

  9. Instant radiography: a computerized support system for industrial radiographers

    International Nuclear Information System (INIS)

    Taiyus, M.K.; Sadique, J.

    1995-08-01

    This work describes an approach for systematic collection of information, organization of these information to create a database, which is based to create a user friendly software ( Instant Radiography). It helps to reduce the vagaries of radiographic practice and reduces the number of trials needed to get good radiographs. This software considers the interrelated and dependent parameters of radiography, e.g., quality of radiation, properties of films, source-to-film distance(SFD), processing conditions etc. and provides precise numerical values for exposure time and other parameters needed for field work. (author), 2 figs., 15 refs

  10. Software development for the management of cephalometric radiographic data

    International Nuclear Information System (INIS)

    BeGole, E.A.

    1980-01-01

    This paper presents the details and logic of a set of three IBM System 370 Assembler Language programs designed to manage a data bank, of ever increasing magnitude, which contains coordinate data obtained from cephalometric radiographs. The data from the radiographs, and consequently, the programs, are primarily intended for use by the orthodontist who is engaged in clinical research, and are especially useful in studies related to changes within the facial and dental complexes which occur as a result of growth and orthodontic treatment. (Auth.)

  11. The Society and College of Radiographers - 60 years on

    International Nuclear Information System (INIS)

    Kinloch, J.

    1980-01-01

    The year 1980 heralded the Diamond Jubilee of the Society and College of Radiographers. A personal review of the history of the Society and College and its aims over the past sixty years is given. The review commences with the formation of the Society in 1920 and follows its testing time throughout the twenties, the expansion of its activities in the period up to the Second World War, its wartime function, its postwar activities particularly in relation to radiographers' conditions of service and salaries and finally the events of the 60's to the present day. (U.K.)

  12. Problematic fine bore nasogastric intubation: A radiographer led service development

    International Nuclear Information System (INIS)

    Law, Robert

    2008-01-01

    Developing from the intubation and performing of small bowel enteroclysis a consultant radiographer led service expanded to include problematic gastric, enteric and colonic intubations for diagnostic, therapeutic and interventional purposes. The radiographer led service has also extended to include 'hot reporting' chest images taken to check siting of ward placed nasogastric tubes as well as resiting those tubes that were misplaced. The service has demonstrated itself to be safe and efficient. It has also proven to be both cost and clinically effective. The protracted discomfort and distress to the patient are reduced by minimizing the delay in correctly relocating misplaced tubes

  13. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  14. Standardized radiographic interpretation of thoracic tuberculosis in children

    International Nuclear Information System (INIS)

    Concepcion, Nathan David P.; Laya, Bernard F.; Andronikou, Savvas; Daltro, Pedro A.N.; Sanchez, Marion O.; Uy, Jacqueline Austine U.; Lim, Timothy Reynold U.

    2017-01-01

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging. (orig.)

  15. Radiographic control of mineral fibre-reinforced cement plates

    International Nuclear Information System (INIS)

    Domanus, J.C.; Moeller Jensen, L.

    1980-03-01

    The usefulnes of the radiographic technique in the examination of Spinrock fibres reinforced cement plates was investigated with soft X-rays. A preliminary investigation has shown that soft X-rays are most suitable for radiography of cement plates, and therefore a 50 kV X-ray machine with a 0.5 mm focus and beryllium window X-ray tube was used througout the investigation. X-ray films of different speed and graininess were used, and it was proved that a relatively fast Kodak Industrex D film can produce radiographs of adequate quality. An Agfa-Gevaert Structurix IC paper can also be used. (author)

  16. Patients exposure assessment for radiographic procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Stankovic, K.; Lazarevic, Dj.; Ciraj-Bjelac, O.)

    2007-01-01

    In this work the results of dose assessment for the most frequent radiographic procedures in diagnostic radiology are shown. Entrance surface doses were assessed for 7 radiographic procedures. Three hospitals, six x-ray units in total, were enrolled in investigation. Patient doses were estimated based on results of x-ray tube output measurements. Finally, doses were compared with Diagnostic reference level. Higher dose values were observed for chest examinations. In comparison with results from other countries, doses from this procedure in Serbia are significantly higher. Estimated doses for other procedures were well below Diagnostic reference levels [sr

  17. Standardized radiographic interpretation of thoracic tuberculosis in children

    Energy Technology Data Exchange (ETDEWEB)

    Concepcion, Nathan David P.; Laya, Bernard F. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Taguig City (Philippines); St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Quezon City (Philippines); Andronikou, Savvas [Bristol Royal Hospital for Children and the University of Bristol, Department of Paediatric Radiology, Bristol (United Kingdom); Daltro, Pedro A.N. [Clinica de Diagnostico por Imagem, Section of Pediatric Radiology, Rio de Janeiro (Brazil); Sanchez, Marion O. [St. Luke' s Medical Center, Section of Pediatric Pulmonology, Institute of Pulmonary Medicine, Quezon City (Philippines); Uy, Jacqueline Austine U. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Taguig City (Philippines); Lim, Timothy Reynold U. [St. Luke' s Medical Center, Section of Pediatric Radiology, Institute of Radiology, Quezon City (Philippines)

    2017-09-15

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging. (orig.)

  18. Destructive spondyloarthropathy and radiographic follow-up in hemodialysis patients

    International Nuclear Information System (INIS)

    Orzincolo, C.; Cardona, P.; Bedani, P.L.; Gilli, P.; Scutellari, P.N.; Trotta, F.

    1990-01-01

    Nine patients undergoing regular dialytic treatment for more than 60 months showed clinical and radiologic features of a noninfective and destructive spondyloarthropathy. Typically, radiographs and CT scans revealed narrowing of intervertebral spaces, with destruction or sclerosis of the subchondral bone of the vertebral plate. A radiographic follow-up of the cervical spine was performed in seven patients after a period of 12 months and showed that the bone destruction in DSA is very rapid and progressive. The lower biocompatibility of the cuprophan membranes of dialyzers is probably the factor most responsible for hyperproduction of β 2 -m and subsequently osteoarticular deposition of a new type of amyloidosis. (orig./DG)

  19. Standardized radiographic interpretation of thoracic tuberculosis in children.

    Science.gov (United States)

    Concepcion, Nathan David P; Laya, Bernard F; Andronikou, Savvas; Daltro, Pedro A N; Sanchez, Marion O; Uy, Jacqueline Austine U; Lim, Timothy Reynold U

    2017-09-01

    There is a lack of standardized approach and terminology to classify the diverse spectrum of manifestations in tuberculosis. It is important to recognize the different clinical and radiographic patterns to guide treatment. As a result of changing epidemiology, there is considerable overlap in the radiologic presentations of primary tuberculosis and post-primary tuberculosis. In this article we promote a standardized approach in clinical and radiographic classification for children suspected of having or diagnosed with childhood tuberculosis. We propose standardized terms to diminish confusion and miscommunication, which can affect management. In addition, we present pitfalls and limitations of imaging.

  20. Development of a portable, high-energy radiographic source

    International Nuclear Information System (INIS)

    Reinhart, E.R.; Wenk, S.A.; Schonberg, R.G.; Mixon, G.L.

    1979-01-01

    The Electric Power Research Institute (EPRI) is sponsoring a two-year program to develop a portable, high-energy (3 to 4 MeV) radiographic system for inservice and repair inspections of components at nuclear power stations. The basic design concept uses a lightweight, portable linear accelerator (LINAC). The design objectives, concepts employed, and progress to date are described. Specific potential applications and accompanying radiographic techniques are discussed, along with the novel beam angulation devices to permit utilization in areas of highly restricted access

  1. Performance of a thermal neutron radiographic system using imaging plates

    International Nuclear Information System (INIS)

    Silvani, Maria Ines; Almeida, Gevaldo L. de; Furieri, Rosanne; Lopes, Ricardo T.

    2009-01-01

    A performance evaluation of a neutron radiographic system equipped with a thermal neutron sensitive imaging plate has been undertaken. It includes the assessment of spatial resolution, linearity, dynamic range and the response to exposure time, as well as a comparison of these parameters with the equivalent ones for neutron radiography employing conventional films and a gadolinium foil as converter. The evaluation and comparison between the radiographic systems have been performed at the Instituto de Engenharia Nuclear - CNEN, using the Argonauta Reactor as source of thermal neutrons and a commercially available imaging plate reader. (author)

  2. Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

    Science.gov (United States)

    Generazio, Edward R.

    1990-01-01

    Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

  3. Macroscopic and radiographic examination of proximal root surface caries

    International Nuclear Information System (INIS)

    Nordenram, G.; Bergvist, A.; Johnson, G.; Henriksen, C.O.; Anneroth, G.

    1988-01-01

    The purpose of the study was to compare macroscopic and radiographic examination of proximal root surface caries of extracted teeth from patients aged 65-95 years. Although the study conditions for macroscopic and radiographic diagnosis favored more sensitive evaluations than routine clinical conditions, there was a 24% disagreement in diagnosis. This finding indicates that under routine clinical conditions it is difficult to register with certainty all superficial root carious lesions. Even in the absence of clinically detectable root surface caries, preventive measures should be considered for elderly people with exposed root surfaces

  4. Radiographic findings in wrists and hands of patients with leprosy

    International Nuclear Information System (INIS)

    Carreto, A.; Montero, F.; Garcia Frasquet, A.; Carpintero, P.

    1998-01-01

    Leprosy, like other neuropathic disorders, can involve the skeleton, affecting both bone and joints, especially those segments that have to withstand weight. To asses the osteoarticular involvement of the wrist and hand in 58 patients with leprosy. The radiographic images of wrist and hand of 58 patients with Hansen's disease were reviewed. The entire spectrum of specific and nonspecific bone lesions described in the literature is presented. Despite the fact that the upper limbs do not have to withstand the weight that the feet and ankles do, radiographic images show that gripping and other common motions can also produce lesions compatible with those of neuropathic arthropathy. (Author) 20 refs

  5. A reflection on the role of an emergency care Consultant Radiographer in achieving appropriate imaging conditions for nasogastric tube positioning

    International Nuclear Information System (INIS)

    Jones, H.C.; Robinson, L.

    2008-01-01

    The College of Radiographers state that the role of a Consultant Radiographer comprises four core functions [College of Radiographers. Developing a business case for consultant radiographers. London: College of Radiographers; 2003; Hardy M, Snaith B. How to achieve consultant practitioner status: a discussion paper. Radiography, in press. doi:10.1016/j.radi.2006.04.003 [accessed 16.08.07

  6. New view on the initial development site and radiographic classification system of osteoarthritis of the knee based on radiographic analysis.

    Science.gov (United States)

    Moon, Ki-Ho

    2012-12-01

    Radiographic pathology of severe osteoarthritis of the knee (OAK) such as severe osteophyte at tibial spine (TS), compartment narrowing, marginal osteophyte, and subchondral sclerosis is well known. Kellgren-Lawrence grading system, which is widely used to diagnose OAK, describes narrowing-marginal osteophyte in 4-grades but uses osteophyte at TS only as evidence of OAK without detailed-grading. However, kinematically the knee employs medial TS as an axis while medial and lateral compartments carry the load, suggesting that early OAK would occur sooner at TS than at compartment. Then, Kellgren-Lawrence system may be inadequate to diagnose early-stage OAK manifested as a subtle osteophyte at TS without narrowing-marginal osteophyte. This undiagnosed-OAK will deteriorate becoming a contributing factor in an increasing incidence of OAK. This study developed a radiographic OAK-marker based on both osteophyte at TS and compartment narrowing-marginal osteophyte and graded as normal, mild, moderate, and severe. With this marker, both knee radiographs of 1,728 patients with knee pain were analyzed. Among 611 early-stage mild OAK, 562 or 92% started at TS and 49 or 8% at compartment. It suggests the initial development site of OAK, helping develop new site-specific radiographic classification system of OAK accurately to diagnose all severity of OAK at early, intermediate, or late-stage. It showed that Kellgren-Lawrence system missed 92.0% of early-stage mild OAK from diagnosis. A subtle osteophyte at TS is the earliest radiographic sign of OAK. A new radiographic classification system of OAK was suggested for accurate diagnosis of all OAK in severity and at stage.

  7. X-ray generator for radiographs of seeds

    International Nuclear Information System (INIS)

    Suarez Canner, E.

    1996-01-01

    It is presented an X-ray generator which is destined to obtaining X-ray radiographs of seeds. It utilizes a low power X-ray tube with fine focal point. It consist of an electronic block and an irradiation chamber

  8. Digital radiographic technology; non-destructive testing of tubine blades

    NARCIS (Netherlands)

    Penumadu, P.S.

    2014-01-01

    Inspection of turbine blades has always been a big challenge. Any irregularities in the blade have a huge impact on the gas turbine, so these blades have to be manufactured and inspected in the most sophisticated way possible. The evolution of digital radiographic technology took a leap forward to

  9. Clinical and radiographic findings of focally infected polycystic kidneys

    International Nuclear Information System (INIS)

    Rothermel, F.J.; Miller, F.J. Jr.; Sanford, E.; Drago, J.; Rohner, T.J.

    1977-01-01

    Three patients with localized polycystic kidney infections are presented with the pertinent clinical, laboratory, and radiographic findings. Gallium-67 citrate and angiography play an important role in evaluation of these patients. Angiography in particular is valuable in the diagnosis and the exact localization of the inflammatory disease. Localization is extremely important in planning surgical treatment should conservative therapy fail

  10. Personalized models of bones based on radiographic photogrammetry.

    Science.gov (United States)

    Berthonnaud, E; Hilmi, R; Dimnet, J

    2009-07-01

    The radiographic photogrammetry is applied, for locating anatomical landmarks in space, from their two projected images. The goal of this paper is to define a personalized geometric model of bones, based uniquely on photogrammetric reconstructions. The personalized models of bones are obtained from two successive steps: their functional frameworks are first determined experimentally, then, the 3D bone representation results from modeling techniques. Each bone functional framework is issued from direct measurements upon two radiographic images. These images may be obtained using either perpendicular (spine and sacrum) or oblique incidences (pelvis and lower limb). Frameworks link together their functional axes and punctual landmarks. Each global bone volume is decomposed in several elementary components. Each volumic component is represented by simple geometric shapes. Volumic shapes are articulated to the patient's bone structure. The volumic personalization is obtained by best fitting the geometric model projections to their real images, using adjustable articulations. Examples are presented to illustrating the technique of personalization of bone volumes, directly issued from the treatment of only two radiographic images. The chosen techniques for treating data are then discussed. The 3D representation of bones completes, for clinical users, the information brought by radiographic images.

  11. Systematic assessment of constipation on plain abdominal radiographs in children

    International Nuclear Information System (INIS)

    Bosch, Maurice van den; Graafmans, Doortje; Nievelstein, Rutger; Beek, Erik

    2006-01-01

    Constipation in childhood is common and its clinical assessment is often difficult. Plain abdominal radiography is simple and used to quantify constipation. Three scoring systems, those of Barr et al., Leech et al. and Blethyn et al., have been developed to quantify fecal loading on the abdominal radiograph. In order to determine which method is the most useful in clinical practice, we assessed the reproducibility of the three scoring systems. Plain abdominal radiographs from 40 clinically constipated children were retrospectively reviewed by two paediatric radiologists on two separate occasions. The radiographs were scored according to three different systems developed by Barr et al., Leech et al., Blethyn et al. Intraobserver variability and interobserver reproducibility were determined for each system. Kappa coefficients were calculated as indicators of inter- and intraobserver agreement for categorical outcome variables. The Leech score showed the highest reproducibility: the intraobserver agreement was high for both observers (κ values of 0.88 and 1.00, respectively, P<0.05). Furthermore, the interobserver agreement was also high: κ 0.91 in the first round and 0.84 in the second. The Leech score proved to be a highly reproducible tool for assessment of childhood constipation and is of value in clinical practice for systematic assessment of constipation on plain abdominal radiographs in children. (orig.)

  12. Acute neuropathic joint in diabetic foot: Plain radiographic findings

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Kang, Heung Sik; Sim, Jung Suk; Yoon, Yong Kyu; Kim, Chu Wan

    1994-01-01

    To determine the plain film findings of acute neuropathic joint in diabetic foot. Acute neuropathic joint in diabetic foot was considered when fragmentation of the articular ends of bone and subluxation of the affected joint developed within eight weeks after clinical onset of diabetic gangrene. Eight toes of six diabetics were satisfactory to our criteria. We analyzed plain radiographic findings of the affected joint and soft tissue, interval changes in followed-up radiographs, and deformities after healing. The time interval between clinical onset of gangrene and bone destruction ranges from 2 weeks to 4 weeks(mean 2.6 weeks). Plane radiographs showed fragmentation of the articular ends, subluxation, and soft tissue swelling of the metatarsophalangeal joint or interphalangeal joint. The significant feature of these patients was rapid progression of the lesions. Clinically, all patients had diabetic gangrene in affected toes, however, there was no evidence of osteomyelitis in our series. Amputation was done in 2 cases, and lesions in 3 of the remaining 4 cases were repaired spontaneously with regression of gangrene, leaving radiological residua such as pointed-end, tapered-end, and ball and socket deformity. Rapid disorganisation of the joint with associated evidence of soft tissue gangrene in plain radiograph is believed to be valuable for the diagnosis of diabetic osteoarthropathy

  13. International Society of Radiographers and Radiological Technologists and radiation protection

    International Nuclear Information System (INIS)

    Yule, A.

    2001-01-01

    The ISRRT was formed in 1962 with 15 national societies and by the year 2000 has grown to comprise more than 70 member societies. The main objects of the organization are to: Improve the education of radiographers; Support the development of medical radiation technology worldwide; Promote a better understanding and implementation of radiation protection standards. The ISRRT has been a non-governmental organization in official relations with the World Health Organization (WHO) since 1967. It is the only international radiographic organization that represents radiation medicine technology and has more than 200 000 members within its 70 member countries. Representatives of the ISRRT have addressed a number of assemblies of WHO regional committees on matters relating to radiation protection and radiation medicine technology. In this way, the expertise of radiographers worldwide contributes to the establishment of international standards in vital areas, such as: Quality control; Legislation for radiation protection; Good practice in radiographic procedures; Basic radiological services. The ISRRT believes that good and consistent standards of practice throughout the world are essential

  14. Development of tools for radiographic defects scanning in ceramic materials

    International Nuclear Information System (INIS)

    Lipnik, Boris.

    1994-03-01

    This work is concentrated on implementation of the most used non-destructive technique - radiography to quality control of structural ceramics. The present thesis deals with microfocus radiographic evaluation of ceramics produced by slip casting method. Radiographic processes are examined relying on image processing by algorithms expanded from others developed for tomographic images of non ceramics objects. At the first stage experiments aimed for characterization of a real-time microfocus radiographic system were carried out. The question of signal-to-noise ratio referring to a defect's detection limit was explored. Arithmetic image operations were used to correct for the background variations. At the second stage microfocus radiographs of: ceramics were systematically processed and analyzed by means of regularization and 'weak membrane' algorithms. The images were considerably improved and it resulted in identification and dimension extraction of defects as small as 40 pico meter . The usefulness of pseudocoloring methods was explored to obtain a fast assessment of gray level variations and to detect more details in the initial digital image. The potential for practical application was found to be very reasonable. The problems experienced were discussed along with suggestions for further studies and improvement

  15. Method and apparatus for improving the alignment of radiographic images

    International Nuclear Information System (INIS)

    Schuller, P.D.; Hatcher, D.C.; Caelli, T.M.; Eggert, F.M.; Yuzyk, J.

    1991-01-01

    This invention relates generally to the field of radiology, and has to do particularly with a method and apparatus for improving the alignment of radiographic images taken at different times of the same tissue structure, so that the images can be sequentially shown in aligned condition, whereby changes in the structure can be noted. (author). 10 figs

  16. Radiographic display of carious lesions and cavitation in approximal surfaces

    DEFF Research Database (Denmark)

    Wenzel, Ann

    2014-01-01

    cavitation in approximal surfaces. Nonetheless, there are several drawbacks with CBCT, such as radiation dose, costs and imaging artefacts. Therefore, CBCT cannot be advocated at current as a primary radiographic examination with the aim of diagnosing cavitated carious lesions. Conclusions. Bitewing...

  17. Basal cell naevus syndrome - radiographic findings in the skull

    Energy Technology Data Exchange (ETDEWEB)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-09-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed.

  18. The basal cell naevus syndrome - radiographic findings in the skull

    International Nuclear Information System (INIS)

    Stoll, P.; Dueker, J.; Weingart, D.

    1986-01-01

    Besides uni- and multiocular jaw cysts the Gorlin Goltz syndrome shows other characteristic radiographic findings which help to ensure diagnosis. These are particularly calcification of the falx cerebri and a so called ''bridging'' between processus clinoideus anterior and posterior of the sella turcica. The importance of early diagnosis is stressed. (orig.) [de

  19. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  20. The radiographic localization of unerupted maxillary incisors and supernumeraries

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Lee, Chang Yul; You, Choong Hyun

    2003-01-01

    To evaluate the use of the vertical tube shift from a panoramic film and a periapical film to localize unerupted maxillary incisors and supernumeraries. The total of 103 displaced maxillary incisors or embedded supernumeraries were examined in this study. The vertical tube shift technique with panoramic and periapical radiography by normal projection taken and compared to localize the position of the embedded maxillary incisors or supernumeraries by a radiologist and 5 general dentists. The gold standard used for the radiographic comparisons was the true position of the embedded tooth as confirmed by horizontal tube shift technique using three periapical radiographs. The general dentist examiners were instructed on the use of the modified acronym 'SLDOBU' by the radiologist as it pertains to panoramic radiographs as the principle of vertical tube shift. All of the embedded maxillary incisors and supernumeraries were successfully located using the vertical tube shift from a panoramic and a maxillary anterior periapical radiograph by the radiologist and 5 general dentists. The use of a panoramic film with a periapical film combination for a vertical tube shift can be useful to localize unerupted maxillary incisors and supernumeraries.

  1. Advanced Neutron Radiographic Equipment within the US Army

    Science.gov (United States)

    2014-01-29

    The first of the two new neutron generators developed for ARDEC was built and delivered by Phoenix Nuclear Labs ( PNL ) located in Madison, WI...PRELIMINARY NEUTRON RADIOGRAPHS AND RESULTS During the hardware and software testing of the PNL neutron generator several test shots were

  2. assessment of the toxicity of radiographic developer effluent

    African Journals Online (AJOL)

    Stephen

    ASSESSMENT OF THE TOXICITY OF RADIOGRAPHIC DEVELOPER ... as a source of food (protein), sporting tools for anglers; and a vital part of the ecosystem (tertiary ... in estuaries and coastal waters which because of the ... particularly vulnerable (Dicks, 1983; Health 1987). .... discharges into the marine and coastal.

  3. Radiation exposure of radiographers who handle 18 F ...

    African Journals Online (AJOL)

    18F-fluorodeoxyglucose (18F-FDG) is used in most diagnostic applications of Positron Emission Tomography (PET). It has high annihilation energy of 511 keV, which results in potentially high radiation doses for staff. This study investigated radiographer radiation exposure during receipt, administration and scanning of ...

  4. The lungs in rheumatoid arthritis - a clinical, radiographic and ...

    African Journals Online (AJOL)

    The lungs in rheumatoid arthritis - a clinical, radiographic and pulmonary function study. Stephen C. Morrison, Girish M. Mody, Sally R. Benatar, Orlando L Meyers. Abstract. Objective. To detennine the prevalence and spectrum of pulmonary abnormalities in patients with rheumatoid arthritis (RA) in a developing country.

  5. Radiographically ossified ganglion cyst of finger in a swimmer

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, J.; Anavim, A. [Department of Radiological Sciences, University of California, Orange (United States); Lin, F. [Department of Pathology, University of California, Irvine Medical Center, Orange (Canada)

    1998-12-01

    Ganglion cysts are fibrous-walled cystic lesions closely associated with joint or tendon sheaths and contain gelatinous mucinous fluid. The radiographic appearance is usually normal. Calcification or ossification in these cysts is extremely unusual. We report on an unusual appearing ganglion cyst of the little finger in a swimmer with ossification resembling myositis ossificans. (orig.) With 3 figs., 8 refs.

  6. Analysis of fuel-bundle radiographs using modeling

    International Nuclear Information System (INIS)

    Demuth, H.B.

    1975-07-01

    It was desired to estimate the thickness of gaps imaged on highly degraded radiographs. A powerful mathematical method for estimating gap widths was developed and applied. The problem, the techniques used to solve the problem, and results, conclusions, and suggestions for future work are presented. (U.S.)

  7. Radiographic evaluation of cases referred for surgical endodontics

    NARCIS (Netherlands)

    Doornbusch, H.; Broersma, L.; Boering, G.; Wesselink, P.R.

    Aim The aim of this study is to test the hypothesis that more patients with failed root-canal treatment or other endodontic problems are referred for periradicular surgery rather than nonsurgical re-treatment. Methodology Three sets of 100 periapical radiographs representing typical cases referred

  8. A radiographic study on the conventional endodontic treatment

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Kwon, Hyuck Choon; You, Dong Soo

    1985-01-01

    The purpose of this study was to evaluate the initial and postoperative radiographic features of the endodontic treated teeth. The author examined the radiographs which comprise 114 teeth with 155 canals of 64 persons. The following factors were considered; Age, sex, tooth location, number of root canal, postoperative periods, initial diagnosis, and radiographic findings, postoperative radiographic findings. The apical levels of the root fillings were 76.8% to apex, 19.0% underfilling, 3.9% overfilling. The following results were obtained. 1. Of the 93 teeth which revealed initial periapical rarefaction, 66 teeth(71.0%) had showed complete bone healing, 19 teeth (20.4%) decreased rarefaction, 6 teeth (6.5%) no change, 2 teeth (2.2%) increased rarefaction after 20.0 months mean healing time. 2. 21 teeth which had on initial periapical rarefaction showed no occurrence of new periapical rarefaction. 3. Of the 66 teeth completely healed, 53 teeth (80.3%) had showed reappearance of laminadura, 64 teeth (97.0%) reappearance of periodontal ligament space after 23.4 months mean healing time.

  9. Radiographic features of tuberculous osteitis in greater trochanter and lschium

    International Nuclear Information System (INIS)

    Hahm, So Hee; Lee, Ye Ri; Kim, Dong Jin; Sung, Ki Jun; Lim, Jong Nam

    1996-01-01

    To evaluate, if possible, the radiographic features of tuberculous osteitis in the greater trochanter and ischium, and to determine the cause of the lesions. We reterospectively reviewed the plain radiographic findings of 14 ptients with histologically proven tuberculous osteitis involving the greater trochanter and ischium. In each case, the following were analyzed:morphology of bone destruction, including cortical erosion;periosteal reaction;presence or abscence of calcific shadows in adjacent soft tissue. On the basis of an analysis of radiographic features and correlation of the anatomy with adjacent structures we attempted to determine causes. Of the 14 cases evaluated, 12 showed varrious degrees of extrinsic erosion on the outer cortical bone of the greater trochanter and ischium ; in two cases, bone destruction was so severe that the radiographic features of advanced perforated osteomyelitis were simulated. In addition to findings of bone destruction, in these twelve cases, the presence of sequestrum or calcific shadows was seen in adjacent soft tissue. Tuberculous osteitis in the greater trochanter and ischium showed the characteristic findings of chronic extrinsic erosion. On the basis of these findings we can suggest that these lesions result from an extrinsic pathophysiologic cause such as adjacent bursitis

  10. Radiographic features of tuberculous osteitis in greater trochanter and lschium

    Energy Technology Data Exchange (ETDEWEB)

    Hahm, So Hee; Lee, Ye Ri [Hanil Hospital Affiliated to KEPCO, Seoul (Korea, Republic of); Kim, Dong Jin; Sung, Ki Jun [Yonsei Univ. Wonju College of Medicine, Wonju (Korea, Republic of); Lim, Jong Nam [Konkuk Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-11-01

    To evaluate, if possible, the radiographic features of tuberculous osteitis in the greater trochanter and ischium, and to determine the cause of the lesions. We reterospectively reviewed the plain radiographic findings of 14 ptients with histologically proven tuberculous osteitis involving the greater trochanter and ischium. In each case, the following were analyzed:morphology of bone destruction, including cortical erosion;periosteal reaction;presence or abscence of calcific shadows in adjacent soft tissue. On the basis of an analysis of radiographic features and correlation of the anatomy with adjacent structures we attempted to determine causes. Of the 14 cases evaluated, 12 showed varrious degrees of extrinsic erosion on the outer cortical bone of the greater trochanter and ischium ; in two cases, bone destruction was so severe that the radiographic features of advanced perforated osteomyelitis were simulated. In addition to findings of bone destruction, in these twelve cases, the presence of sequestrum or calcific shadows was seen in adjacent soft tissue. Tuberculous osteitis in the greater trochanter and ischium showed the characteristic findings of chronic extrinsic erosion. On the basis of these findings we can suggest that these lesions result from an extrinsic pathophysiologic cause such as adjacent bursitis.

  11. Radiographic analysis of body composition by computerized axial tomography

    International Nuclear Information System (INIS)

    Heymsfield, S.B.

    1986-01-01

    Radiographic methods of evaluating body composition have been applied for over five decades. A marked improvement in this approach occurred in the mid-nineteen-seventies with the introduction of computerized axial tomography. High image contrast, cross-sectional imaging and rapid computerized data processing make this technique a sophisticated clinically applicable tool. (author)

  12. Gender determination from diagnostic factors on anteroposterior pelvic radiographs

    Directory of Open Access Journals (Sweden)

    Azadeh Memarian

    2017-03-01

    Conclusion: The results of this study revealed that the evaluation of the radiographic images of pelvic bones by assessing the mentioned factors can be useful for sex determination from skeletal remains. However, ethical considerations should also be taken into account while using these factors.

  13. Para-acetabular peritendinitis calcarea; its radiographic manifestations

    International Nuclear Information System (INIS)

    Kawashima, Akira; Murayama, Sadayuki; Ohuchida, Toshiyuki; Russell, W.J.

    1987-02-01

    Peritendinitis calcarea and os acetabuli have long been confused during interpretations of hip-joint radiographs. Such confusion is reflected in the medical literature. The present study differentiated these two entities according to their interval radiographic progression and regression. There were 137 instances of para-acetabular calcifications among 110 subjects (59 men and 51 women), whose mean age was 46.8 years at the time of their initial detection. Twenty-six of the subjects had lumbago, which was probably unrelated. Other abnormalities including narrowed intervertebral spaces, scoliosis, and spondylolysis were observed in 21 of the subjects. These could have been responsible for any symptoms they had had, but none of the subjects complained of local hip-joint pain when the radiographs in question were made. Ninety-three of these instances of calcification were reviewed by means of serial radiographs. Interval changes in the sizes and shapes of the calcifications occurred among 90 of them, indicative of the latent type of peritendinitis calcarea. No interval changes were noted in the remaining three cases, indicating they were secondary ossification centers; namely, os acetabuli. This study showed that in asymptomatic adults, most para-acetabular calcifications were really not os acetabuli, but actually peritendinitis calcarea. (author)

  14. A radiographic study of alveolar bone loss in Irish schoolchildren

    International Nuclear Information System (INIS)

    Buckley, L.A.

    1982-01-01

    Bitewing radiographs were used to assess evidence of alveolar bone loss in 1492 children in the age range 7-12 years. According to the method used in this study, alveolar bone loss was shown to occur in 1.7% of the children, and maxillary teeth were affected twice as frequently as mandibular teeth. (Author)

  15. Radiographic evaluation of degenerative joint disease in horses: interpretive principles

    International Nuclear Information System (INIS)

    Widmer, W.R.; Blevins, W.E.

    1994-01-01

    Degenerative joint disease in horses is characterized by the progressive deterioration of articular cartilage of synovial joints. The morbidity associated with degenerative joint disease, particularly the loss of function in pleasure and performance horses, costs horse owners millions of dollars each year. Although new drugs, such as polysulfated glycosaminoglycans and hyaluronic acid, are available for the treatment of patients with degenerative joint disease, the success of therapy depends on early diagnosis. Diagnostic imaging strategies, therefore, should focus on accurate and timely diagnosis of degenerative joint disease to provide prompt therapy. Early identification of degenerative joint disease is also beneficial because the use and/or training methods of affected patients may be altered, possibly limiting the progression of the disease. The pathogenesis of degenerative joint disease is complex and multifactorial. Current evidence suggests that initiating factors lead to a final common pathway-breakdown of articular cartilage. There are many diagnostic tests that aid practitioners in detecting degenerative joint disease; however, the most important imaging technique is radiography. During the early stages of the disease, radiographic changes may be slight; therefore, it is essential that practitioners have adequate equipment to obtain high-quality radiographs. Thinning of the joint space, osteophytosis, enthesopathy, changes in subchondral bone, and increased synovium and synovia provide radiographic evidence of degenerative joint disease. By understanding the pathophysiology of the disease and how technical alterations affect the subtle radiographic changes, practitioners can more accurately diagnose degenerative joint disease during its early stages and institute proper therapy

  16. Justification of radiographic examinations: What are the key issues?

    OpenAIRE

    Vom, Jason; Williams, Imelda

    2017-01-01

    Abstract Justification of radiographic examinations is the practice of evaluating requested radiological examinations to assess for clinical merit and appropriateness based on clinical notes and patient information. This implies that justification in radiography requires the evaluation of requested examinations, the justification of exposures being applied and determining whether patients fit the recommended criteria for the procedure. Medico?legal requirements by the professional registratio...

  17. Guesstimation of posterior malleolar fractures on lateral plain radiographs

    NARCIS (Netherlands)

    Meijer, D. T.; Doornberg, J. N.; Sierevelt, I. N.; Mallee, W. H.; van Dijk, C. N.; Kerkhoffs, G. M.; Stufkens, S. A.; Palmanovich, Ezequiel; van Sterkenburg, Maayke; Engvall, Andreas; Arroyo, Ernesto; Golovakha, Maksym; Pereira, Ernesto; Josep Torrent, Eugene Toh; Haverkamp, Daniel; Bojanic, Ivan; Sousa, Manuel; Aragon, Oscar Castro; Russo, Alessandro; Cortes, Carlos; Pánics, Gergely; Vide, João; Spanos, Loannis; Carvalho, Manuel Santos; Maggi, Pablo; Thomas, Zach; Tanaka, Hirofumi; Dinato, Mauro; Fay, Jakob; Kimtys, Vytautas; Correia Moreira, António José; Hatziemmanuil, Dimitrios; Low, Tze-Choong; van der Plaat, Laurens Wessel; Mora, Allan David; van Rensen, Inge; del Vecchio, Javier; Ramos, James; Azevedo, Jorge; Bustamante, Carlos; Oliveira, Alexandre; Zaw, Htwe; Kurup, Harish; Yli-Kyyny, Tero; Baca, Emre; Haapasalo, Heidi; Bakhtamyan, Gurgen; Zbikowski, Piotr; van den Bekerom, Michel; de Muinck Keizer, Robert-Jan

    2015-01-01

    Accurate assessment of articular involvement of the posterior malleolar fracture fragments in ankle fractures is essential, as this is the leading argument for internal fixation. The purpose of this study is to assess diagnostic accuracy of measurements on plain lateral radiographs. Quantification

  18. Systematic assessment of constipation on plain abdominal radiographs in children

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, Maurice van den; Graafmans, Doortje [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Nievelstein, Rutger; Beek, Erik [Wilhelmina Children' s Hospital, Department of Paediatric Radiology, Utrecht (Netherlands)

    2006-03-15

    Constipation in childhood is common and its clinical assessment is often difficult. Plain abdominal radiography is simple and used to quantify constipation. Three scoring systems, those of Barr et al., Leech et al. and Blethyn et al., have been developed to quantify fecal loading on the abdominal radiograph. In order to determine which method is the most useful in clinical practice, we assessed the reproducibility of the three scoring systems. Plain abdominal radiographs from 40 clinically constipated children were retrospectively reviewed by two paediatric radiologists on two separate occasions. The radiographs were scored according to three different systems developed by Barr et al., Leech et al., Blethyn et al. Intraobserver variability and interobserver reproducibility were determined for each system. Kappa coefficients were calculated as indicators of inter- and intraobserver agreement for categorical outcome variables. The Leech score showed the highest reproducibility: the intraobserver agreement was high for both observers ({kappa} values of 0.88 and 1.00, respectively, P<0.05). Furthermore, the interobserver agreement was also high: {kappa} 0.91 in the first round and 0.84 in the second. The Leech score proved to be a highly reproducible tool for assessment of childhood constipation and is of value in clinical practice for systematic assessment of constipation on plain abdominal radiographs in children. (orig.)

  19. Estimation of lung volumes from chest radiographs using shape information

    International Nuclear Information System (INIS)

    Pierce, R.J.; Brown, D.J.; Holmes, M.; Cumming, G.; Denison, D.M.

    1979-01-01

    The cross-sectional shapes of the chest and its contained structures were assessed in post-mortem anatomical sections and from computerised tomographic scans in living subjects. These shapes are described by simple equations that can be used to increase the accuracy of measuring lung volumes from chest radiographs. Radiographic estimates of total lung capacity, using the equations, were compared with plethysmographic and single-breath helium dilution measurements in 35 normal subjects. After correction for posture effects the radiographic estimates of TLC, which measure the displacement volume of the lung, exceeded the plethysmographic estimates of contained gas volume by a mean of 720 ml, which was taken as the volume of tissue, blood, and water in the lungs. The single-breath dilution estimates of TLC fell short of the plethysmographic values by a mean of 480 ml, taken as the volume of contained gas that was inaccessible to helium in 10 seconds. The tomographic studies suggested that the radiographic technique of measuring lung displacement volumes has an accuracy of +- 210 ml. The method is rapid and simple to use and the intra- and inter-observer variabilities of <1% and <5% respectively. (author)

  20. Reliable Radiographic Inspection of Flexible Risers for the Oil Industry

    Science.gov (United States)

    Almeida, Rômulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-01

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.