  1. Intraarticular Pulsed Radiofrequency to Treat Refractory Lumbar Facet Joint Pain in Patients with Low Back Pain.

    Science.gov (United States)

    Chang, Min Cheol; Cho, Yun-Woo; Ahn, Da Hyun; Do, Kyung Hee

    2018-04-01

    Many treatment techniques have been used for refractory lumbar facet joint pain; however, their efficacy has been controversial. In this study, we investigated the clinical efficacy and safety of intra-articular pulsed radiofrequency for the treatment of refractory lumbar facet joint pain in patients with low back pain. Twenty patients with refractory lumbar facet joint pain were recruited, and each patient was treated via intra-articular pulsed radiofrequency. The treatment effects were measured with a numerical rating scale, and the technical accuracy of intra-articular pulsed radiofrequency treatment was evaluated independently by 2 radiologists. Any adverse events or complications also were checked. We performed intra-articular pulsed radiofrequency treatment at 48 levels of the lumbar facet joints in 20 patients (5 men and 15 women; mean age, 64.50 ± 10.65 years) with refractory lumbar facet joint pain. Pain scores were significantly reduced at 1 month, 3 months, and 6 months after treatment (P radiofrequency results in all 20 patients, without any serious adverse effects. Treatment using intra-articular pulsed radiofrequency is an alternative to other techniques in patients with refractory lumbar facet joint pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Bipolar Radiofrequency Facet Ablation of the Lumbar Facet Capsule: An Adjunct to Conventional Radiofrequency Ablation for Pain Management.

    Science.gov (United States)

    Jacobson, Robert E; Palea, Ovidiu; Granville, Michelle

    2017-09-01

    Radiofrequency facet ablation (RFA) has been performed using the same technique for over 50 years. Except for variations in electrode size, tip shape, and change in radiofrequency (RF) stimulation parameters, using standard, pulsed, and cooled RF wavelengths, the target points have remained absolutely unchanged from the original work describing RFA for lumbar pain control. Degenerative changes in the facet joint and capsule are the primary location for the majority of lumbar segmental pathology and pain. Multiple studies show that the degenerated facet joint is richly innervated as a result of the inflammatory overgrowth of the synovium. The primary provocative clinical test to justify an RFA is to perform an injection with local anesthetic into the facet joint and the posterior capsule and confirm pain relief. However, after a positive response, the radiofrequency lesion is made not to the facet joint but to the more proximal fine nerve branches that innervate the joint. The accepted target points for the recurrent sensory branch ignore the characteristic rich innervation of the pathologic lumbar facet capsule and assume that lesioning of these recurrent branches is sufficient to denervate the painful pathologic facet joint. This report describes the additional targets and technical steps for further coagulation points along the posterior capsule of the lumbar facet joint and the physiologic studies of the advantage of the bipolar radiofrequency current in this location. Bipolar RF to the facet capsule is a simple, extra step that easily creates a large thermo-coagulated lesion in this capsule region of the pathologic facet joint. Early studies demonstrate bipolar RF to the facet capsule can provide long-term pain relief when used alone for specific localized facet joint pain, to coagulate lumbar facet cysts to prevent recurrence, and to get more extensive pain control by combining it with traditional lumbar RFA, especially when RFA is repeated.

  3. Direct Posterior Bipolar Cervical Facet Radiofrequency Rhizotomy: A Simpler and Safer Approach to Denervate the Facet Capsule.

    Science.gov (United States)

    Palea, Ovidiu; Andar, Haroon M; Lugo, Ramon; Granville, Michelle; Jacobson, Robert E

    2018-03-14

    Radiofrequency cervical rhizotomy has been shown to be effective for the relief of chronic neck pain, whether it be due to soft tissue injury, cervical spondylosis, or post-cervical spine surgery. The target and technique have traditionally been taught using an oblique approach to the anterior lateral capsule of the cervical facet joint. The goal is to position the electrode at the proximal location of the recurrent branch after it leaves the exiting nerve root and loops back to the cervical facet joint. The standard oblique approach to the recurrent nerve requires the testing of both motor and sensory components to verify the correct position and ensure safety so as to not damage the slightly more anterior nerve root. Bilateral lesions require the repositioning of the patient's neck. Poorly positioned electrodes can also pass anteriorly and contact the nerve root or vertebral artery. The direct posterior approach presented allows electrode positioning over a broader expanse of the facet joint without risk to the nerve root or vertebral artery. Over a four-year period, direct posterior radiofrequency ablation was performed under fluoroscopic guidance at multiple levels without neuro-stimulation testing with zero procedural neurologic events even as high as the C2 spinal segment. The direct posterior approach allows either unipolar or bipolar lesioning at multiple levels. Making a radiofrequency lesion along the larger posterior area of the facet capsule is as effective as the traditional target point closer to the nerve root but technically easier, allowing bilateral access and safety. The article will review the anatomy and innervation of the cervical facet joint and capsule, showing the diffuse nerve supply extending into the capsule of the facet joint that is more extensive than the recurrent medial sensory branches that have been the focus of radiofrequency lesioning.

  4. A new technique to treat facet joint pain with pulsed radiofrequency.

    Science.gov (United States)

    Schianchi, Pietro Martino

    2015-02-01

    Facet joint pain affects 5% to 15% of the population with low back pain and the prevalence increases with age due to progression of arthritis. While conservative treatments are often unsuccessful, the scientific evidence on minimally invasive therapies such as intra-articular steroid infiltration and continuous and pulsed radiofrequency (PRF) of the medial branches is contradictory. Since PRF has recently been reported to successfully treat joint pain, a new application of this method is proposed for facetogenic lumbar pain via an intra-articular subcapsular approach. Here we reported two cases with successful treatment. A 71-year-old patient presented because of persisting pain in the left gluteal region radiating to the lateral thigh and calf when standing. Anti-inflammatory drugs produced only short-lasting insufficient relief. A 52-year-old employee was admitted in June 2012 because of axial lower lumbar pain with intermittent diffuse radiation to the right lower extremity that worsened during walking and lying down despite receiving analgesics and physiotherapy. A new approach to treat lumbar facet joint pain with PRF is simple to perform and without serious complications. In view of the good long-lasting results obtained with the two reported cases, randomized control trials are necessary to validate this new approach.

  5. The efficacy of conventional radiofrequency denervation in patients with chronic low back pain originating from the facet joints: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Kim, Chi Heon

    2017-11-01

    Radiofrequency denervation is commonly used for the treatment of chronic facet joint pain that has been refractory to more conservative treatments, although the evidence supporting this treatment has been controversial. We aimed to elucidate the precise effects of radiofrequency denervation in patients with low back pain originating from the facet joints relative to those obtained using control treatments, with particular attention to consistency in the denervation protocol. A meta-analysis of randomized controlled trials was carried out. Adult patients undergoing radiofrequency denervation or control treatments (sham or epidural block) for facet joint disease of the lumbar spine comprised the patient sample. Visual analog scale (VAS) pain scores were measured and stratified by response of diagnostic block procedures. We searched PubMed, Embase, Web of Science, and the Cochrane Database for randomized controlled trials regarding radiofrequency denervation and control treatments for back pain. Changes in VAS pain scores of the radiofrequency group were compared with those of the control group as well as the minimal clinically important difference (MCID) for back pain VAS. Meta-regression model was developed to evaluate the effect of radiofrequency treatment according to responses of diagnostic block while controlling for other variables. We then calculated mean differences and 95% confidence intervals (CIs) using random-effects models. We included data from seven trials involving 454 patients who had undergone radiofrequency denervation (231 patients) and control treatments such as sham or epidural block procedures (223 patients). The radiofrequency group exhibited significantly greater improvements in back pain score when compared with the control group for 1-year follow-up. Although the average improvement in VAS scores exceeded the MCID, the lower limit of the 95% CI encompassed the MCID. A subgroup of patients who responded very well to diagnostic block

  6. Management of lumbar zygapophysial (facet) joint pain

    Science.gov (United States)

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Falco, Frank JE; Boswell, Mark V

    2016-01-01

    . RESULTS: Across all databases, 16 high quality diagnostic accuracy studies were identified. In addition, multiple studies assessed the influence of multiple factors on diagnostic validity. In contrast to diagnostic validity studies, therapeutic efficacy trials were limited to a total of 14 randomized controlled trials, assessing the efficacy of intraarticular injections, facet or zygapophysial joint nerve blocks, and radiofrequency neurotomy of the innervation of the facet joints. The evidence for the diagnostic validity of lumbar facet joint nerve blocks with at least 75% pain relief with ability to perform previously painful movements was level I, based on a range of level I to V derived from a best evidence synthesis. For therapeutic interventions, the evidence was variable from level II to III, with level II evidence for lumbar facet joint nerve blocks and radiofrequency neurotomy for long-term improvement (greater than 6 mo), and level III evidence for lumbosacral zygapophysial joint injections for short-term improvement only. CONCLUSION: This review provides significant evidence for the diagnostic validity of facet joint nerve blocks, and moderate evidence for therapeutic radiofrequency neurotomy and therapeutic facet joint nerve blocks in managing chronic low back pain. PMID:27190760

  7. Cervical facet joint dysfunction: a review.

    Science.gov (United States)

    Kirpalani, Dhiruj; Mitra, Raj

    2008-04-01

    To review the relevant literature on cervical facet joint dysfunction and determine findings regarding its anatomy, etiology, prevalence, clinical features, diagnosis, and treatment. A computer-aided search of several databases was performed, including Medline (1966 to present), Ovid (1966 to present), and the Cochrane database (1993 to present). Selected articles had the following criteria: (1) all articles analyzed cervical facet joint pain-anatomy, prevalence, etiology, diagnosis, treatment; (2) only full, published articles were studied, not abstracts; and (3) all articles were published in English. All articles were critically evaluated and included the following categories: randomized controlled trials, meta-analyses, uncontrolled clinical trials, uncontrolled comparison studies, nonquantitative systematic reviews, and literature-based reviews. We examined 45 references that consisted of 44 journal articles and relevant sections from 1 textbook. Cervical facet joints have been well established in the literature as a common nociceptive pain generator, with an estimated prevalence that ranges from 25% to 66% of chronic axial neck pain. No studies have reported clinical examination findings that are diagnostic for cervical facet mediated pain. Overall the literature provides very limited information regarding the treatment of this condition, with only radiofrequency neurotomy showing evidence of effectively reducing pain from cervical facet joint dysfunction.

  8. Randomised sham-controlled double-blind multicentre clinical trial to ascertain the effect of percutaneous radiofrequency treatment for lumbar facet joint pain.

    Science.gov (United States)

    van Tilburg, C W J; Stronks, D L; Groeneweg, J G; Huygen, F J P M

    2016-11-01

    The aim of this study was to compare the effect of a percutaneous radiofrequency heat lesion at the medial branch of the primary dorsal ramus with a sham procedure, for the treatment of lumbar facet joint pain. A randomised sham-controlled double blind multicentre trial was carried out at the multidisciplinary pain centres of two hospitals. A total of 60 patients aged > 18 years with a history and physical examination suggestive of facet joint pain and a decrease of ≥ 2 on a numerical rating scale (NRS 0 to 10) after a diagnostic facet joint test block were included. In the treatment group, a percutaneous radiofrequency heat lesion (80 o C during 60 seconds per level) was applied to the medial branch of the primary dorsal ramus. In the sham group, the same procedure was undertaken without for the radiofrequency lesion. Both groups also received a graded activity physiotherapy programme. The primary outcome measure was decrease in pain. A secondary outcome measure was the Global Perceived Effect scale (GPE). There was a statistically significant effect on the level of pain in the factor Period (T0-T1). However, there was no statistically significant difference with the passage of time between the groups (Group × Period) or in the factor Group. In the crossover group, 11 of 19 patients had a decrease in NRS of ≥ 2 at one month crossover (p = 0.65). There was no statistically significant difference in satisfaction with the passage of time between the groups (Group × Period). The independent factors Group and Period also showed no statistically significant difference. There was no statistically significant Group × Period effect for recovery, neither an effect of Group or of Period. The null hypothesis of no difference in the decrease in pain and in GPE between the treatment and sham groups cannot be rejected. Post hoc analysis revealed that the age of the patients and the severity of the initial pain significantly predicted a positive outcome. Cite this article

  9. Audit of conservative management of chronic low back pain in a secondary care setting--part I: facet joint and sacroiliac joint interventions.

    Science.gov (United States)

    Chakraverty, Robin; Dias, Richard

    2004-12-01

    The work of a chronic back pain service in secondary care in the West Midlands is reported. The service offers acupuncture, spinal injection procedures, osteopathy and a range of other interventions for patients whose back pain has not responded to conservative management. This section of the report focuses on injection procedures for lumbar facet joint and sacroiliac joint pain, which have been shown to be the cause of chronic low back pain in 16-40% and 13-19% of patients respectively. Diagnosis relies on the use of intra-articular or sensory nerve block injections with local anaesthetic. Possible treatments following diagnosis include intra-articular corticosteroid, radiofrequency denervation (for facet joint pain) or ligament prolotherapy injections (for sacroiliac joint pain). The results of several hospital audits are reported. At six month follow up, 50% of 38 patients undergoing radiofrequency denervation following diagnostic blocks for facet joint pain had improved by more than 50%, compared to 29% of 34 patients treated with intra-articular corticosteroid injection. Sixty three per cent of 19 patients undergoing prolotherapy following diagnostic block injection for sacroiliac joint pain had improved at six months, compared to 33% of 33 who had intra-articular corticosteroid. Both radiofrequency denervation and sacroiliac prolotherapy showed good long-term outcomes at one year.

  10. Arthrography of the lumber facet joint and facet block

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hee Kyung; Chung, Tae Sub; Kim, Young Soo; Park, Hyung Chun; Moon, Jae Ho; Suh, Jung Ho; Kim, Dong Ik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    In spite of numerous clinical and patho-anatomical studied made in the past, there are still different opinions concerning the mechanism of low back pain. We have focused attention on the posterior structures as an alternative source of low back pain with sciatica. So we have studied and analyzed the finding of arthrography of facet joint and effect of the injection of methyprednisolone acetate suspension (Depomedrol) 20mg into the each facet joint. Our results are as follows: 1. Abnormal findings of facet joint arthrogram were degenerative osteoarthritis of facet joint (70.5%), synovial cyst (11.8%), accessory bone (11.8%), and spondylolysis (5.9%). 2. The mean facet angulations of patients of facet syndrome were abnormal on lower lumbar facet joint in 9 of 13 cases (69.2%). 3. On initial assessment, 11 of 17 cases (64.7%) showed complete relief and one month later, 6 of 11 cases (35.3%) showed continuous relief, after steroid injection.

  11. Arthrography of the lumber facet joint and facet block

    International Nuclear Information System (INIS)

    Cho, Hee Kyung; Chung, Tae Sub; Kim, Young Soo; Park, Hyung Chun; Moon, Jae Ho; Suh, Jung Ho; Kim, Dong Ik

    1988-01-01

    In spite of numerous clinical and patho-anatomical studied made in the past, there are still different opinions concerning the mechanism of low back pain. We have focused attention on the posterior structures as an alternative source of low back pain with sciatica. So we have studied and analyzed the finding of arthrography of facet joint and effect of the injection of methyprednisolone acetate suspension (Depomedrol) 20mg into the each facet joint. Our results are as follows: 1. Abnormal findings of facet joint arthrogram were degenerative osteoarthritis of facet joint (70.5%), synovial cyst (11.8%), accessory bone (11.8%), and spondylolysis (5.9%). 2. The mean facet angulations of patients of facet syndrome were abnormal on lower lumbar facet joint in 9 of 13 cases (69.2%). 3. On initial assessment, 11 of 17 cases (64.7%) showed complete relief and one month later, 6 of 11 cases (35.3%) showed continuous relief, after steroid injection.

  12. Facet joint syndrome

    International Nuclear Information System (INIS)

    Zigrai, M.; Zakovic, J.; Brezinova, M.; Pavlovicova, M.

    2002-01-01

    It is the purpose of the study to demonstrate the clinical relevance of degenerative changes in the facet joint of patients with low back pain irradiating to the lower extremities, and discuss some problems relating to diagnosis and different diagnosis. 119 patients presenting the listed bellow syndromes are covered by the study: scoliosis, polytopic pain vertebral syndrome, paresis and history of trauma. all patients undergo comprehensive neurological examination with special attention focused on the spine: CT and plain x-rays are taken of the lumbosacral segment to assess the condition of the facet joints. The neurological examination demonstrates in all cases pain syndrome in the lumbar spine referred to one or both lower extremities. In 56% it is a matter of persisting pain, and in 44% - recurrent. More than half of the patients complain of sacroiliac (SI) dislocation and palpatory pain. Unilateral or bilateral degenerative changes are documented by imaging studies in all patients, including: subchondral thickening, osteopathy narrowing the lateral or central part of the spinal canal with ensuing nerve root compression. The lumbosacral zygoapophyseal joints are source of pseudoradicular pain. A correlation between clinical picture and GT changes is noted in all patients with facet joint syndrome. CT is an indispensable method in diagnosing facet joint syndrome. (authors)

  13. Optimized cervical spine bone SPET for detection of facet joint injury after whiplash injury

    Energy Technology Data Exchange (ETDEWEB)

    Cardaci, G T; Bower, G D; Taylor, J [Perth and Perth Pain Management, South Perth, WA (Australia). Mount Medical Centre, Isotope Imaging

    1999-04-01

    Full text: The most frequent origin for chronic cervical pain in patients with a remote history of whiplash injury is the cervical facet joints. Exact localization of facet joint injury is difficult and currently advocated methods include multiple invasive diagnostic injections. Optimization of {sup 99}Tc{sup m}-HDP cervical SPET (CSPET) to accurately localize facet joint pathology was attempted and the results correlated with clinical localization relying on focal joint tenderness and passive movement methods. Imaging was performed on a dual-headed gamma camera system using an elliptical orbit over 360 deg. The patient's neck was flexed to eliminate the cervical lordosis. Reconstructed CSPET images were reorientated into the long axis of the vertebral bodies. CSPET studies were independently scored by two observers blinded to the clinical and other imaging information and correlated with clinical localization and response to radiofrequency ablation. 54 patients have been studied using this technique in a prospective study. Early patient follow-up data will be presented. CSPET was felt to be clinically useful by pain therapists in targeting treatment.

  14. Optimized cervical spine bone SPET for detection of facet joint injury after whiplash injury

    International Nuclear Information System (INIS)

    Cardaci, G.T.; Bower, G.D.; Taylor, J.

    1999-01-01

    Full text: The most frequent origin for chronic cervical pain in patients with a remote history of whiplash injury is the cervical facet joints. Exact localization of facet joint injury is difficult and currently advocated methods include multiple invasive diagnostic injections. Optimization of 99 Tc m -HDP cervical SPET (CSPET) to accurately localize facet joint pathology was attempted and the results correlated with clinical localization relying on focal joint tenderness and passive movement methods. Imaging was performed on a dual-headed gamma camera system using an elliptical orbit over 360 deg. The patient's neck was flexed to eliminate the cervical lordosis. Reconstructed CSPET images were reorientated into the long axis of the vertebral bodies. CSPET studies were independently scored by two observers blinded to the clinical and other imaging information and correlated with clinical localization and response to radiofrequency ablation. 54 patients have been studied using this technique in a prospective study. Early patient follow-up data will be presented. CSPET was felt to be clinically useful by pain therapists in targeting treatment

  15. Computed Tomography of the lumbar facet joints

    International Nuclear Information System (INIS)

    Choi, Mi Ryoung; Kim, Yung Soon; Lee, Joo Hyuk; Jeon, Hae Sang; Kim, Dae Yung

    1989-01-01

    The lumbar facet disease is a frequently overlooked cause of sciatic pain, but the lumbar facet joints are well-recognized source of low back pain and radiating leg pain which can be confused with sciatica due to herniated disc. We measured the angulation of the facet joints on axial spine CT films in 149 cases which contains 41 normal group and 108 abnormal group and studied the relationship between the angulation and degeneration of the facets, the asymmetry of each sided facets and facet degeneration, the asymmetry and disc protrusion, and the asymmetry and annular bulging of the disc. The results were as follows: 1. Facet angulation in abnormal group were more sagittally oriented than the normal group. 2. The angulation of right facet was more sagittally oriented than the left in L4-5 level of abnormal group. 3. Degeneration of facet joints occur asymmetrically, and the more facet joint degenerates, the more it orients sagittally, particularly in L4-5. 4. Asymmetry in facet joint degeneration and unilateral disc protrusion of L5-SI level is greater than the normal group

  16. Computed Tomography of the lumbar facet joints

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Mi Ryoung; Kim, Yung Soon; Lee, Joo Hyuk; Jeon, Hae Sang; Kim, Dae Yung [Kang Nam General Hospital, Seoul (Korea, Republic of)

    1989-08-15

    The lumbar facet disease is a frequently overlooked cause of sciatic pain, but the lumbar facet joints are well-recognized source of low back pain and radiating leg pain which can be confused with sciatica due to herniated disc. We measured the angulation of the facet joints on axial spine CT films in 149 cases which contains 41 normal group and 108 abnormal group and studied the relationship between the angulation and degeneration of the facets, the asymmetry of each sided facets and facet degeneration, the asymmetry and disc protrusion, and the asymmetry and annular bulging of the disc. The results were as follows: 1. Facet angulation in abnormal group were more sagittally oriented than the normal group. 2. The angulation of right facet was more sagittally oriented than the left in L4-5 level of abnormal group. 3. Degeneration of facet joints occur asymmetrically, and the more facet joint degenerates, the more it orients sagittally, particularly in L4-5. 4. Asymmetry in facet joint degeneration and unilateral disc protrusion of L5-SI level is greater than the normal gro0008.

  17. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    Science.gov (United States)

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially

  18. Relationship between facet tropism and facet joint degeneration in the sub-axial cervical spine

    Directory of Open Access Journals (Sweden)

    Xin Rong

    2017-02-01

    Full Text Available Abstract Background Facet tropism is the angular asymmetry between the left and right facet joint orientation. Although debatable, facet tropism was suggested to be associated with disc degeneration, facet degeneration and degenerative spondylolisthesis in the lumbar spine. The purpose of this study was to explore the relationship between facet tropism and facet degeneration in the sub-axial cervical spine. Methods A total of 200 patients with cervical spondylosis were retrospectively analyzed. Facet degeneration was categorized into 4 grade: grade I, normal; grade II, degenerative changes including joint space narrowing, cyst formation, small osteophytes (3 mm without fusion of the joint; grade IV, bony fusion of the facet joints. Facet orientations and facet tropisms with respect to the transverse, sagittal and coronal plane were calculated from the reconstructed cervical spine, which was based on the axial CT scan images. The paired facet joints were then categorized into three types: symmetric, moderated tropism and severe tropism. Univariate and multivariate analysis were performed to evaluate the relationship between any demographic and anatomical factor and facet degeneration. Results The mean age of enrolled patients was 46.23 years old (ranging from 30 to 64 years old. There were 114 males and 86 females. The degrees of facet degeneration varied according to cervical levels and ages. Degenerated facet joints were most common at C2-C3 level and more common in patients above 50 years old. The facet orientations were also different from level to level. By univariate analysis, genders, ages, cervical levels, facet orientations and facet tropisms were all significantly different between the normal facets and degenerated facets. However, results from multivariate logistic regression suggested only age and facet tropism with respect to the sagittal plane were related to facet degeneration. Conclusion Facet degeneration were more common at

  19. Augmented Reality-Guided Lumbar Facet Joint Injections.

    Science.gov (United States)

    Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda

    2018-05-08

    The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.

  20. Biochemical and biomechanical characterisation of equine cervical facet joint cartilage.

    Science.gov (United States)

    O'Leary, S A; White, J L; Hu, J C; Athanasiou, K A

    2018-04-15

    The equine cervical facet joint is a site of significant pathology. Located bilaterally on the dorsal spine, these diarthrodial joints work in conjunction with the intervertebral disc to facilitate appropriate spinal motion. Despite the high prevalence of pathology in this joint, the facet joint is understudied and thus lacking in viable treatment options. The goal of this study was to characterise equine facet joint cartilage and provide a comprehensive database describing the morphological, histological, biochemical and biomechanical properties of this tissue. Descriptive cadaver studies. A total of 132 facet joint surfaces were harvested from the cervical spines of six skeletally mature horses (11 surfaces per animal) for compiling biomechanical and biochemical properties of hyaline cartilage of the equine cervical facet joints. Gross morphometric measurements and histological staining were performed on facet joint cartilage. Creep indentation and uniaxial strain-to-failure testing were used to determine the biomechanical compressive and tensile properties. Biochemical assays included quantification of total collagen, sulfated glycosaminoglycan and DNA content. The facet joint surfaces were ovoid in shape with a flat articular surface. Histological analyses highlighted structures akin to articular cartilage of other synovial joints. In general, biomechanical and biochemical properties did not differ significantly between the inferior and superior joint surfaces as well as among spinal levels. Interestingly, compressive and tensile properties of cervical facet articular cartilage were lower than those of articular cartilage from other previously characterised equine joints. Removal of the superficial zone reduced the tissue's tensile strength, suggesting that this zone is important for the tensile integrity of the tissue. Facet surfaces were sampled at a single, central location and do not capture the potential topographic variation in cartilage properties. This

  1. Unilateral spondylolysis and the presence of facet joint tropism.

    Science.gov (United States)

    Rankine, James J; Dickson, Robert A

    2010-10-01

    Retrospective review of the CT scans performed in a group of patients examined for a possible spondylolysis. To investigate whether there is an association between unilateral spondylolysis and facet joint tropism. Spondylolysis is a fatigue fracture of the pars interarticularis of great importance in sports injury. The demonstration of a unilateral spondylolysis is important because there is a potential for full healing if the athletic activity is modified, whereas bilateral spondylolysis frequently leads to established nonunion. Coronally orientated facet joints are known to predispose to spondylolysis by increasing the point loading of the pars interarticularis. The importance of this finding has not been investigated in unilateral spondylolysis. A review of patients with low back pain and a possible diagnosis of spondylolysis who were investigated with multislice CT was performed. The coronal orientation of the facet joints at L4/5 and L5/S1 was measured and comparison was done between those with and without a spondylolysis. The coronal angle of 140 facet joints in 35 patients was recorded. Of 35 patients, 23 had a spondylolysis which was unilateral in 12 patients. The facet joint angle was significantly more coronally orientated in the presence of a spondylolysis when compared with an intact pars (means, 53° and 43°, respectively; P spondylolysis, the facet joint was significantly more coronally orientated on the side of the spondylolysis (means, 52° and 45°, respectively; P spondylolysis. Asymmetric facet joints do increase the force through one side of the spine, with a unilateral spondylolysis occurring on the side of the more coronally orientated facet joint.

  2. Utilization of Facet Joint and Sacroiliac Joint Interventions in Medicare Population from 2000 to 2014: Explosive Growth Continues!

    Science.gov (United States)

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Pampati, Vidyasagar; Boswell, Mark V

    2016-10-01

    Increasing utilization of interventional techniques in managing chronic spinal pain, specifically facet joint interventions and sacroiliac joint injections, is a major concern of healthcare policy makers. We analyzed the patterns of utilization of facet and sacroiliac joint interventions in managing chronic spinal pain. The results showed significant increase of facet joint interventions and sacroiliac joint injections from 2000 to 2014 in Medicare FFS service beneficiaries. Overall, the Medicare population increased 35 %, whereas facet joint and sacroiliac joint interventions increased 313.3 % per 100,000 Medicare population with an annual increase of 10.7 %. While the increases were uniform from 2000 to 2014, there were some decreases noted for facet joint interventions in 2007, 2010, and 2013, whereas for sacroiliac joint injections, the decreases were noted in 2007 and 2013. The increases were for cervical and thoracic facet neurolysis at 911.5 % compared to lumbosacral facet neurolysis of 567.8 %, 362.9 % of cervical and thoracic facet joint blocks, 316.9 % of sacroiliac joints injections, and finally 227.3 % of lumbosacral facet joint blocks.

  3. Effect of Radiofrequency Denervation on Pain Intensity Among Patients With Chronic Low Back Pain: The Mint Randomized Clinical Trials.

    Science.gov (United States)

    Juch, Johan N S; Maas, Esther T; Ostelo, Raymond W J G; Groeneweg, J George; Kallewaard, Jan-Willem; Koes, Bart W; Verhagen, Arianne P; van Dongen, Johanna M; Huygen, Frank J P M; van Tulder, Maurits W

    2017-07-04

    Radiofrequency denervation is a commonly used treatment for chronic low back pain, but high-quality evidence for its effectiveness is lacking. To evaluate the effectiveness of radiofrequency denervation added to a standardized exercise program for patients with chronic low back pain. Three pragmatic multicenter, nonblinded randomized clinical trials on the effectiveness of minimal interventional treatments for participants with chronic low back pain (Mint study) were conducted in 16 multidisciplinary pain clinics in the Netherlands. Eligible participants were included between January 1, 2013, and October 24, 2014, and had chronic low back pain, a positive diagnostic block at the facet joints (facet joint trial, 251 participants), sacroiliac joints (sacroiliac joint trial, 228 participants), or a combination of facet joints, sacroiliac joints, or intervertebral disks (combination trial, 202 participants) and were unresponsive to conservative care. All participants received a 3-month standardized exercise program and psychological support if needed. Participants in the intervention group received radiofrequency denervation as well. This is usually a 1-time procedure, but the maximum number of treatments in the trial was 3. The primary outcome was pain intensity (numeric rating scale, 0-10; whereby 0 indicated no pain and 10 indicated worst pain imaginable) measured 3 months after the intervention. The prespecified minimal clinically important difference was defined as 2 points or more. Final follow-up was at 12 months, ending October 2015. Among 681 participants who were randomized (mean age, 52.2 years; 421 women [61.8%], mean baseline pain intensity, 7.1), 599 (88%) completed the 3-month follow-up, and 521 (77%) completed the 12-month follow-up. The mean difference in pain intensity between the radiofrequency denervation and control groups at 3 months was -0.18 (95% CI, -0.76 to 0.40) in the facet joint trial; -0.71 (95% CI, -1.35 to -0.06) in the sacroiliac joint

  4. Hypertrophic Synovitis of the Facet Joint Causing Root Pain

    Directory of Open Access Journals (Sweden)

    Koichi Iwatsuki M.D.

    2008-01-01

    Full Text Available Osteoarthritic changes in the facet joints are common in the presence of degenerative disc disease. Changes in the joint capsule accompany changes in the articular surfaces. Intraspinal synovial cysts that cause radicular pain, cauda equina syndrome, and myelopathy have been reported; however, there have been few reports in orthopedic or neurosurgical literature regarding hypertrophic synovitis of the facet joint presenting as an incidental para-articular mass. Here, we report a case of hypertrophic synovitis causing root pain. We describe the case of a 65-year-old man suffering from right sciatica and right leg pain in the L5 nerve-root dermatome for 1 year; magnetic resonance imaging (MRI revealed an enhanced mass around the L4–5 facet joint. We investigated this mass pathologically. After right medial facetectomy, the symptoms resolved. Pathological investigation revealed this mass was hypertrophic synovitis. Hypertrophic synovitis of the facet joint might cause root pain.

  5. Factors affecting results of fluoroscopy-guided facet joint injection: Probable differences in the outcome of treatment between pure facet joint hypertrophy and concomitant diseases

    Directory of Open Access Journals (Sweden)

    Akif Albayrak

    2016-01-01

    Full Text Available Study Design: Retrospective cohort study. Purpose: Facet joints are considered a common source of chronic low-back pain. To determine whether pathogens related to the facet joint arthritis have any effect on treatment failure. Materials and Methods: Facet joint injection was applied to 94 patients treated at our hospital between 2011 and 2012 (mean age 59.5 years; 80 women and 14 men. For the purpose of analysis, the patients were divided into two groups. Patients who only had facet hypertrophy were placed in group A (47 patients, 41 women and 6 men, mean age 55.3 years and patients who had any additional major pathology to facet hypertrophy were placed in group B (47 patients, 39 women and 8 men, mean age 58.9 years. Injections were applied around the facet joint under surgical conditions utilizing fluoroscopy device guidance. A mixture of methylprednisolone and lidocaine was used as the injection ingredient. Results: In terms of Oswestry Disability Index (ODI and visual analog scale (VAS scores, no significant difference was found between preinjection and immediate postinjection values in both groups, and the scores of group A patients were significantly lower (P < 0.005 compared with that of group B patients at the end of the third, sixth, and twelfth month. Conclusion: For low-back pain caused by facet hypertrophy, steroid injection around the facet joint is an effective treatment, but if there is an existing major pathology, it is not as effective.

  6. Correlation of the Features of the Lumbar Multifidus Muscle With Facet Joint Osteoarthritis.

    Science.gov (United States)

    Yu, Bo; Jiang, Kaibiao; Li, Xinfeng; Zhang, Jidong; Liu, Zude

    2017-09-01

    Facet joint osteoarthritis is considered a consequence of the aging process; however, there is evidence that it may be associated with degenerative changes of other structures. The goal of this study was to investigate the correlation between lumbar multifidus muscle features and facet joint osteoarthritis. This retrospective study included 160 patients who had acute or chronic low back pain and were diagnosed with facet joint osteoarthritis on computed tomography scan. Morphometric parameters, including cross-sectional area, muscle-fat index, and percentage of bilateral multifidus asymmetry at L3-L4, L4-L5, and L5-S1, were evaluated with T2-weighted magnetic resonance imaging. Patients with facet joint osteoarthritis had a smaller cross-sectional area and a higher muscle-fat index than those without facet joint osteoarthritis (Posteoarthritis at all 3 spinal levels (Posteoarthritis only at L4-L5 (P=.005). Asymmetry of the bilateral multifidus cross-sectional area was independently associated with facet joint osteoarthritis at L5-S1 (P=.009), but did not seem to be responsible for asymmetric degeneration of the bilateral facet joints. A higher multifidus muscle-fat index was independently associated with facet joint osteoarthritis, and bilateral multifidus size asymmetry was associated with the development of facet joint osteoarthritis at L5-S1. It seems more accurate to consider facet joint osteoarthritis a failure of the whole joint structure, including the paraspinal musculature, rather than simply a failure of the facet joint cartilage. [Orthopedics. 2017; 40(5):e793-e800.]. Copyright 2017, SLACK Incorporated.

  7. Image-guided lumbar facet joint infiltration in nonradicular low back pain

    International Nuclear Information System (INIS)

    Chaturvedi, Arti; Chaturvedi, Sunil; Sivasankar, Rajiv

    2009-01-01

    To assess the efficacy of facet joint infiltrations for pain relief in 44 selected patients with chronic nonradicular low back pain (LBP). Forty-four patients with chronic LBP of more than 3 months' duration were selected for facet joint infiltration. The majority (n = 24) had facetal pain with no evidence of significant facetal arthropathy on imaging. Fifteen patients had radiological evidence of facetal arthropathy, one had a facet joint synovial cyst, three were post–lumbar surgery patients, and two patients had spondylolysis. Facet joint injections were carried out under fluoroscopic guidance in 39 patients and under CT guidance in 5 cases. Pain relief was assessed using the visual analog scale at 1 h post-procedure and, thereafter, at 1, 4, 12, and 24 weeks. A total of 141 facet joints were infiltrated in 44 patients over a 2-year period. There was significant pain relief in 81.8% patients 1 h after the procedure, in 86.3% after 1 week, in 93.3% after 4 weeks, in 85.7% after 12 weeks, and in 62.5% after 24 weeks. No major complications were encountered. Facet nerve block was found to be a simple, minimally invasive, and safe procedure. With meticulous patient selection, we achieved long-term success rates of over 60%. We conclude that this method represents an important alternative treatment for nonradicular back pain

  8. Lumbar facet syndrome - Lumbar facet joint injection and low back pain

    International Nuclear Information System (INIS)

    Acevedo Gonzalez, Juan Carlos; Jimenez Hakim, Enrique; Rodriguez, Jose Maria; Hakim Daccach, Fernando; Quinonez, German; Rodriguez Munera, Andres

    2004-01-01

    The authors conducted a retrospective study lo evaluate the effectiveness of injection therapy in the lumbar zygapophysial joints with anesthetics and steroids in patients with persisting low back pain and lumbar facer syndrome. Thirty-seven patients with low back pain who reported immediate relief of their pain after controlled blocks into the facet joints between the fourth and fifth lumbar vertebrae and the fifth lumbar and first sacral vertebrae were evaluated. Outcome was evaluated using the visual analog pain scales. All outcome measures were repeated at eight days and six weeks alter controlled injection. At six-week follow-up examination 83,7% of thirty-seven patients experienced a good response to controlled blocks of the lumbar zygaphyseal (facet) joints. Good result is the pain relief of 50% or more. Fifteen patients experienced a good response with pain relief of eight points or more in the VAS

  9. Subdural empyema following lumbar facet joint injection: An exceeding rare complication.

    Science.gov (United States)

    Fayeye, Oluwafikayo; Silva, Adikarige Haritha Dulanka; Chavda, Swarupsinh; Furtado, Navin Raoul

    2016-01-01

    Chronic low back pain is extremely common with a life time prevalence estimated at greater than 70%. Facet joint arthrosis is thought to be the causative aetiological substrate in approximately 25% of chronic low back pain cases. Facet joint injection is a routine intervention in the armamentarium for both the diagnostic and therapeutic management of chronic low back pain. In fact, a study by Carrino et al. reported in excess of 94,000 facet joint injection procedures were carried out in the US in 1999. Although generally considered safe, the procedure is not entirely without risk. Complications including bleeding, infection, exacerbation of pain, dural puncture headache, and pneumothorax have been described. We report a rare case of a 47-year-old female patient who developed a left L4/5 facet septic arthrosis with an associated subdural empyema and meningitis following facet joint injection. This case is unique, as to the best of our knowledge no other case of subdural empyema following facet joint injection has been reported in the literature. Furthermore this case serves to highlight the potential serious adverse sequelae of a routine and apparently innocuous intervention. The need for medical practitioners to be alert to and respond rapidly to the infective complications of facet joint injection cannot be understated. Copyright © 2016 Polish Neurological Society. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  10. Percutaneous Facet Screw Fixation in the Treatment of Symptomatic Recurrent Lumbar Facet Joint Cyst: A New Technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr; Gallo, Giacomo, E-mail: giacomo.gallo83@gmail.com; Bertrand, Anne-Sophie, E-mail: asbertrand3@hotmail.com [Centre Hospitalier Universitaire de Nice (France); Bard, Robert L., E-mail: rbard@cancerscan.com [New York Medical College (United States); Kelekis, Alexis, E-mail: akelekis@med.uoa.gr [University General Hospital “ATTIKON” (Greece)

    2016-01-15

    We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation could be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.

  11. Uncovertebral joint injury in cervical facet dislocation: the headphones sign

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, Francesco; Cassar-Pullicino, Victor N.; Dell' Atti, Claudia; Lalam, Radhesh K.; Tins, Bernhard J.; Tyrrell, Prudencia N.M.; McCall, Iain W. [Robert Jones and Agnes Hunt Orthopaedic and District Hospital, Department of Radiology, Oswestry, England (United Kingdom)

    2006-06-15

    The purpose of our study is to demonstrate the uncovertebral mal-alignment as a reliable indirect sign of cervical facet joint dislocation. We examined the uncovertebral axial plane alignment of 12 patients with unilateral and bilateral cervical facet joint dislocation (UCFJD and BCFJD, respectively), comparing its frequency to the reverse hamburger bun sign on CT and MR axial images. Of the seven cases with BCFJD, five clearly demonstrated the diagnostic reverse facet joint hamburger bun sign on CT and MR images, but in two cases this sign was not detectable. In the five cases with UCFJD, four demonstrated the reverse hamburger bun sign on both CT and MRI. In one case the reverse hamburger bun sign was not seen adequately with either image modality, but the facet dislocation was identified on sagittal imaging. The uncovertebral mal-alignment was detected in all 12 cases. Normally, the two components of the uncovertebral joint enjoy a concentric relationship that in the axial plane is reminiscent of the relationship of headphones with the wearer's head. We name this appearance the 'headphones' sign. Radiologists should be aware of the headphones sign as a reliable indicator of facet joint dislocation on axial imaging used in the assessment of cervical spine injuries. (orig.)

  12. Facet joint orientation and tropism in lumbar degenerative disc disease and spondylolisthesis.

    Science.gov (United States)

    Pichaisak, Witchate; Chotiyarnwong, Chayaporn; Chotiyarnwong, Pojchong

    2015-04-01

    Although degenerative disc disease (DDD) and degenerative spondylolisthesis (DS) are two common causes of back pain in elderly, the association between the lumbarfacet joint angle and tropism in these conditions are still unclear. To evaluate the difference in facet joint angles between normal population and lumbar degenerative disc disease and spondylolisthesis patient. The angle of lumbar facet joints were retrospectively measured with magnetic resonance imaging (MRI) to determine whether there was a difference between degenerative diseases. MRI of patients with DDD, DS, and control group at facet joint between L3-4, L4-5 and L5-S1 level were measured in axial view (60 subjects in each group). There was no difference infacetjoint angle in DDD (44.1 ± 11.9) and control (45.6 ± 8.9), but differed in DS (40.1 ± 10. 7) and control group (p = 0.010) at L4-5 level. Facet tropism showed difference between degenerative groups and control group at L4-5 level. DS group showed difference in facet joints angle and tropism when compared with control population, while DDD showed difference only in facet tropism. In addition, longitudinal studies are needed to understand the clinical significant between facet joint angle and tropism in spinal degenerative diseases.

  13. Treatment of lumbar facet joint syndrome by CT-guided intraarticular infiltration of fact joints

    International Nuclear Information System (INIS)

    Schleifer, J.; Fenzl, G.; Wolf, A.; Diehl, K.

    1994-01-01

    In 62 patients with facet syndrome a total of 205 joints were infiltrated, CT monitoring being used in all cases. Each facet joint was infiltrated with 0.3 ml bupivacaine and 0.8 ml methylprednisolone. The patients were divided into three groups. Group 1 consisted of 24 persons who had undergone lumbar disc surgery, group 2 of 23 patients with spondylarthrosis of the facet joints, and group 3 of 15 patients who had undergone lumbar disc surgery but hat additional spondylarthrosis. Very good results were defined as pain relief for longer than 4 weeks, good results as pain relief for up to 4 weeks and poor results as brief pain relief or none at all. In 27 patients facet infiltration was performed for the purpose of diagnosis. Results were significantly in group 2 than in group 1. In group 3 results were better than in group 1, but worse than in group 2. These differences were not statistical by significant. Seven patients in the diagnostic group had no pain relief, and facet syndrome was excluded. (orig.) [de

  14. Degenerative Changes of the Facet Joints in Adults With Lumbar Spondylolysis.

    Science.gov (United States)

    Goda, Yuichiro; Sakai, Toshinori; Harada, Taihei; Takao, Shoichiro; Takata, Yoichiro; Higashino, Kosaku; Harada, Masafumi; Sairyo, Koichi

    2017-07-01

    Radiologic analysis using computed tomography. To analyze the degenerative changes of the facet joints in patients with spondylolysis in comparison with control subjects. Defects of the pars interarticularis are thought to result in a reduction of biomechanical stress on adjacent facet joints. Therefore, degenerative changes of the facet joints in patients with spondylolysis are expected to be less than those in patients without spondylolysis. Abdominal and pelvic multidetector computed tomography scans of 2000 subjects, performed for conditions unrelated to low back pain, were reviewed. A total of 107 patients (37 women and 70 men) with L5 spondylolysis were identified [spondylolysis (+) group]. Sex-matched and age-matched controls without spondylolysis were chosen randomly [spondylolysis (-) group]. Subjects in the spondylolysis group were subdivided into either bilateral spondylolysis or unilateral spondylolysis groups for comparison with the control group. Four radiologic findings (narrowing, sclerosis, osteophyte, and bone cyst) indicative of degenerative change of the facet joints adjacent to the L5 pars defects were evaluated and the degree of degenerative change was graded by summing the number of degenerative changes (score range, 0-4). The χ test and Mann-Whitney U test were used for statistical analysis. Significantly more degenerative changes in both L4/L5 and L5/S facet joints were found in the spondylolysis (+) group than in the spondylolysis (-) group (χ test, P spondylolysis (+) group than in the spondylolysis (-) group. Degenerative changes of the facet joints at both L4/L5 and L5/S were more severe in the unilateral spondylolysis (+) group than in the spondylolysis (-) group. Degenerative changes of the facet joints in patients with lumbar spondylolysis were more severe than those without spondylolysis.

  15. [Feasibility and accuracy of ultrasound-guided methodology in the examination of lumbar spine facet joints].

    Science.gov (United States)

    Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui

    2013-03-01

    To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.

  16. Isolated Facet Joint Fracture as a Cause of Chronic Low Back Pain and Sciatica

    Directory of Open Access Journals (Sweden)

    Robert W Teasell

    1996-01-01

    Full Text Available A case of facet joint fracture following a rear-end motor vehicle accident who presented with chronic low back pain and sciatica is outlined. Diagnosis was made with 99Tc nuclear bone scan and was confirmed on computed tomographic scan after diagnosis with regular radiographs had failed. Facetectomy relieved pain but led to symptoms related to asymmetric load on the opposite facet joint. Symptoms were substantially relieved with a facet joint deinnervation procedure. Facet joint fracture was felt to occur as a consequence of compression forces on the facet joint at the time of impact.

  17. Facet joint injuries in acute cervical spine trauma : evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Jeon Ju; Kim, Dong Hyun; Lee, Jeong Hwa; Lee, Keon; Kwon, Hyeok Po; Kwon, Jung Hyeok; Yun, Seong Mun [Dongkang General Hospital, Seoul (Korea, Republic of)

    1999-05-01

    To evaluate injury patterns of facet joints and associated soft tissue injuries in patients with acute traumatic cervical facet joint injuries. From among patients with cervical spine trauma, 27 with facet joint injuries, as seen on CT and MRI, were chosen for this study. CT scans were analyzed with regard to the location of facet joint injury, the presence or absence of facet dislocation or fracture, and other associated fractures. MR images were analyzed with regard to ligament injury, intervertebral disc injury, intervertebral disc herniation, and spinal cord injury. The most common location of facet joint injury was C6-7 level(n=10), followed by C5-6(n=8). Among these 27 patients with facet joint injuries, 12(44%) had bilateral injuries and 15(56%) unilateral injuries. Facet fractures were present in 17 cases(63%) and the fracture of inferior facet was more frequent than superior. Patterns of fracture were vertical, transverse, or comminuted, but vertical fracture was the most common. Various degrees of dislocation were observed in patients with facet fractures. Fractures other than facet included pillar(n=11), lamina(n=6), transverse process(n=14), body(n=13), and spinous process(n=3). On MR images, anterior longitudinal ligament injury was found in 8 patients(30%), posterior longitudinal ligament injury in 4(15%), and interspinous ligament injury in 20(74%). Twelve patients(44%) had spinal cord injuries including edema(n=8) and hemorrhage(n=4). Among patients with disc abnormalities, 11(41%) had intervertebral disc injuries, and traumatic disc herniations were found in nine. Traumatic cervical facet joint injuries were manifested as various patterns and frequently associated with other fractures or soft tissue injuries. Analysis of CT and MR findings of these injury patterns helped formulate a therapeutic plan and determine of prognosis.

  18. Does sensory stimulation threshold affect lumbar facet radiofrequency denervation outcomes? A prospective clinical correlational study.

    Science.gov (United States)

    Cohen, Steven P; Strassels, Scott A; Kurihara, Connie; Lesnick, Ivan K; Hanling, Steven R; Griffith, Scott R; Buckenmaier, Chester C; Nguyen, Conner

    2011-11-01

    Radiofrequency facet denervation is one of the most frequently performed procedures for chronic low back pain. Although sensory stimulation is generally used as a surrogate measure to denote sufficient proximity of the electrode to the nerve, no study has examined whether stimulation threshold influences outcome. We prospectively recorded data in 61 consecutive patients undergoing lumbar facet radiofrequency denervation who experienced significant pain relief after medial branch blocks. For each nerve lesioned, multiple attempts were made to maximize sensory stimulation threshold (SST). Mean SST was calculated on the basis of the lowest stimulation perceived at 0.1-V increments for each medial branch. A positive outcome was defined as a ≥50% reduction in back pain coupled with a positive satisfaction score lasting ≥3 months. The relationship between mean SST and denervation outcomes was evaluated via a receiver's operating characteristic (ROC) curve, and stratifying outcomes on the basis of various cutoff values. No correlation was noted between mean SST and pain relief at rest (Pearson's r=-0.01, 95% confidence interval [CI]: -0.24 to 0.23, P=0.97), with activity (r=-0.17, 95% CI: -0.40 to 0.07, P=0.20), or a successful outcome. No optimal SST could be identified. There is no significant relationship between mean SST during lumbar facet radiofrequency denervation and treatment outcome, which may be due to differences in general sensory perception. Because stimulation threshold was optimized for each patient, these data cannot be interpreted to suggest that sensory testing should not be performed, or that high sensory stimulation thresholds obtained on the first attempt should be deemed acceptable.

  19. Comparison of facet joint activity on 99mTc-MDP SPECT/CT with facet joint signal change on MRI with fat suppression.

    Science.gov (United States)

    Lehman, Vance T; Murphy, Robert C; Schenck, Louis A; Carter, Rickey E; Johnson, Geoffrey B; Kotsenas, Amy L; Morris, Jonathan M; Nathan, Mark A; Wald, John T; Maus, Timothy P

    2016-01-01

    We compared signal change on magnetic resonance imaging (MRI) with fat suppression and bone scan activity of lumbar facet joints to determine if these two imaging findings are correlated. We retrospectively identified all patients who underwent imaging of the lumbar spine for pain evaluation using both technetium-99m methylene disphosphonate single-photon emission computed tomography/computed tomography (99mTc-MDP SPECT/CT) and MRI with at least one fat-suppressed T2- or T1-weighted sequence with gadolinium enhancement within a 180-day interval, at our institution between 1 January 2008 and 19 February 2013. Facet joint activity on 99mTc-MDP SPECT/CT and peri-facet signal change on MRI were rated as normal or increased. Agreement between the two examination types were determined with the κ and prevalence-adjusted bias-adjusted κ (PABAK) statistics. This study included 60 patients (28 male, 47%), with a mean age of 49±19.7 years (range, 12-93 years). The κ value indicated no agreement between 99mTc-MDP SPECT/CT and MRI (κ=-0.026; 95% confidence interval: -0.051, 0.000). The PABAK values were fair to high at each spinal level, which suggests that relatively low disease prevalence lowered the κ values. Together, the κ and PABAK values indicate that there is some degree of intermodality agreement, but that it is not consistent. Overall, facet joint signal change on fat-suppressed MRI did not always correlate with increased 99mTc-MDP SPECT/CT activity. MRI and 99mTc-MDP SPECT/CT for facet joint evaluation should not be considered interchangeable examinations in clinical practice or research.

  20. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    Science.gov (United States)

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint.

  1. Isolation and Characterization of Human Mesenchymal Stem Cells From Facet Joints and Interspinous Ligaments.

    Science.gov (United States)

    Kristjánsson, Baldur; Limthongkul, Worawat; Yingsakmongkol, Wicharn; Thantiworasit, Pattarawat; Jirathanathornnukul, Napaphat; Honsawek, Sittisak

    2016-01-01

    A descriptive in vitro study on isolation and differentiation of human mesenchymal stem cells (MSCs) derived from the facet joints and interspinous ligaments. To isolate cells from the facet joints and interspinous ligaments and investigate their surface marker profile and differentiation potentials. Lumbar spinal canal stenosis and ossification of the posterior longitudinal ligament are progressive conditions characterized by the hypertrophy and ossification of ligaments and joints within the spinal canal. MSCs are believed to play a role in the advancement of these diseases and the existence of MSCs has been demonstrated within the ligamentum flavum and posterior longitudinal ligament. The aim of this study was to investigate whether these cells could also be found within facet joints and interspinous ligaments. Samples were harvested from 10 patients undergoing spinal surgery. The MSCs from facet joints and interspinous ligaments were isolated using direct tissue explant technique. Cell surface antigen profilings were performed via flow cytometry. Their lineage differentiation potentials were analyzed. The facet joints and interspinous ligaments-derived MSCs have the tri-lineage potential to be differentiated into osteogenic, adipogenic, and chondrogenic cells under appropriate inductions. Flow cytometry analysis revealed both cell lines expressed MSCs markers. Both facet joints and interspinous ligaments-derived MSCs expressed marker genes for osteoblasts, adipocytes, and chondrocytes. The facet joints and interspinous ligaments may provide alternative sources of MSCs for tissue engineering applications. The facet joints and interspinous ligaments-derived MSCs are part of the microenvironment of the human ligaments of the spinal column and might play a crucial role in the development and progression of degenerative spine conditions.

  2. The prevalence of lumbar facet joint edema in patients with low back pain

    International Nuclear Information System (INIS)

    Friedrich, Klaus M.; Pinker, Katja; Trattnig, Siegfried; Nemec, Stefan; Peloschek, Philipp; Weber, Michael

    2007-01-01

    The objective was to assess the prevalence of lumbar facet joint edema in patients with low back pain. Lumbar spine MR examinations (1.5 T) of 145 consecutive patients (87 women, 58 men; mean age 52.8, range 17-94 years) were retrospectively evaluated with regard to the presence of facet joint edema. The MR protocol included sagittal short-tau inversion recovery (STIR), T1- and T2-weighted as well as transverse T2-weighted images. In 9 patients follow-up MR examinations were performed and results were compared with pain. The agreement between the change in intensity of facet joint edema and the change in intensity of pain was assessed using kappa statistics and Kendall's tau coefficient. In 21 of the 145 patients (14%) edema was found at the facet joints: in 52.4% at L4/5, in 19.0% at L5/S1, in 14.3% at L4/5 and L5/S1, in 9.5% at L3/4 and L4/5, and in 4.8% at L3/4. The agreement between the change in pain score and intensity of edema within the follow-up group was ''almost perfect'' (kappa = 0.81). Kendall's tau coefficient was 0.91, indicating high agreement. Sagittal STIR images detect facet joint edema in 14% of patients with low back pain. This fact may be useful for planning treatment including facet joint injections. (orig.)

  3. MR imaging and CT in osteoarthritis of the lumbar facet joints

    International Nuclear Information System (INIS)

    Weishaupt, D.; Zanetti, M.; Hodler, J.; Boos, N.

    1999-01-01

    Objective. To test the agreement between MR imaging and CT in the assessment of osteoarthritis of the lumbar facet joints, and thus to provide data about the need for an additional CT scan in the presence of an MR examination. Design and patients. Using a four-point scale, two musculoskeletal radiologists independently graded the severity of osteoarthritis of 308 lumbar facet joints on axial T2-weighted and on sagittal T1- and T2-weighted turbo-spin-echo images and separately on the corresponding axial CT scans. Kappa statistics and percentage agreement were calculated. Results. The weighted kappa coefficients for MR imaging versus CT were 0.61 and 0.49 for readers 1 and 2, respectively. The weighted kappa coefficients for interobserver agreement were 0.41 for MR imaging and 0.60 for CT, respectively. There was agreement within one grade between MR and CT images in 95% of cases for reader 1, and in 97% of cases for reader 2. Conclusion. With regard to osteoarthritis of the lumbar facet joints there is moderate to good agreement between MR imaging and CT. When differences of one grade are disregarded agreement is even excellent. Therefore, in the presence of an MR examination CT is not required for the assessment of facet joint degeneration. (orig.)

  4. Cooled radiofrequency denervation for treatment of sacroiliac joint pain: two-year results from 20 cases

    Science.gov (United States)

    Ho, Kok-Yuen; Hadi, Mohamed Abdul; Pasutharnchat, Koravee; Tan, Kian-Hian

    2013-01-01

    Background Sacroiliac joint pain is a common cause of chronic low back pain. Different techniques for radiofrequency denervation of the sacroiliac joint have been used to treat this condition. However, results have been inconsistent because the variable sensory supply to the sacroiliac joint is difficult to disrupt completely using conventional radiofrequency. Cooled radiofrequency is a novel technique that uses internally cooled radiofrequency probes to enlarge lesion size, thereby increasing the chance of completely denervating the sacroiliac joint. The objective of this study was to evaluate the efficacy of cooled radiofrequency denervation using the SInergy™ cooled radiofrequency system for sacroiliac joint pain. Methods The charts of 20 patients with chronic sacroiliac joint pain who had undergone denervation using the SInergy™ cooled radiofrequency system were reviewed at two years following the procedure. Outcome measures included the Numeric Rating Scale for pain intensity, Patient Global Impression of Change, and Global Perceived Effect for patient satisfaction. Results Fifteen of 20 patients showed a significant reduction in pain (a decrease of at least three points on the Numeric Rating Scale). Mean Numeric Rating Scale for pain decreased from 7.4 ± 1.4 to 3.1 ± 2.5, mean Patient Global Impression of Change was “improved” (1.4 ± 1.5), and Global Perceived Effect was reported to be positive in 16 patients at two years following the procedure. Conclusion Cooled radiofrequency denervation showed long-term efficacy for up to two years in the treatment of sacroiliac joint pain. PMID:23869175

  5. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping.

    Science.gov (United States)

    Stelzeneder, David; Messner, Alina; Vlychou, Marianna; Welsch, Goetz H; Scheurecker, Georg; Goed, Sabine; Pieber, Karin; Pflueger, Verena; Friedrich, Klaus M; Trattnig, Siegfried

    2011-11-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading ("normal" vs. "abnormal" discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab.

  6. Quantitative in vivo MRI evaluation of lumbar facet joints and intervertebral discs using axial T2 mapping

    International Nuclear Information System (INIS)

    Stelzeneder, David; Messner, Alina; Scheurecker, Georg; Goed, Sabine; Friedrich, Klaus M.; Trattnig, Siegfried; Vlychou, Marianna; Welsch, Goetz H.; Pieber, Karin; Pflueger, Verena

    2011-01-01

    To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading (''normal'' vs. ''abnormal'' discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab. (orig.)

  7. In vivo facet joint loading of the canine lumbar spine.

    Science.gov (United States)

    Buttermann, G R; Schendel, M J; Kahmann, R D; Lewis, J L; Bradford, D S

    1992-01-01

    This study describes a technique to measure in vivo loads and the resultant load-contact locations in the facet joint of the canine lumbar spine. The technique is a modification of a previously described in vitro method that used calibrated surface strains of the lateral aspect of the right L3 cranial articular process. In the present study, strains were measured during various in vivo static and dynamic activities 3 days after strain gage implantation. The in vivo recording technique and its errors, which depend on the location of the applied facet loads, is described. The results of applying the technique to five dogs gave the following results. Relative resultant contact load locations on the facet tended to be in the central and caudal portion of the facet in extension activities, central and cranial in standing, and cranial and ventral in flexion or right-turning activities. Right-turning contact locations were ventral and cranial to left-turning locations. Resultant load locations at peak loading during walking were in the central region of the facet, whereas resultant load locations at minimum loading during walking were relatively craniad. This resultant load-contact location during a walk gait cycle typically migrated in an arc with a displacement of 4 mm from minimum to maximum loading. Static tests resulted in a range of facet loads of 0 N in flexion and lying to 185 N for two-legged standing erect, and stand resulted in facet loads of 26 +/- 15 N (mean +/- standard deviation [SD]). Dynamic tests resulted in peak facet loads ranging from 55 N while walking erect to 170 N for climbing up stairs. Maximum walk facet loads were 107 +/- 27 N. The technique is applicable to in vivo studies of a canine facet joint osteoarthritis model and may be useful for establishing an understanding of the biomechanics of low-back pain.

  8. An observational feasibility study to assess the safety and effectiveness of intranasal fentanyl for radiofrequency ablations of the lumbar facet joints

    Directory of Open Access Journals (Sweden)

    Bartoszek MW

    2017-02-01

    Full Text Available Michael W Bartoszek,1 Amy McCoart,2 Kyung-soo Jason Hong,3 Chelsey Haley,2 Krista Beth Highland,4 Anthony R Plunkett1 1Department of Anesthesiology, Womack Army Medical Center, Fort Bragg, NC, 2Clinical Investigations, Defense and Veterans Center for Integrative Pain Management, Henry M. Jackson Foundation, Womack Army Medical Center, Fort Bragg, NC, 3Research Department, The Center for Clinical Research, Sceptor Pain Foundation, Winston Salem, NC, 4Defense and Veterans Center for Integrative Pain Management, Henry M. Jackson Foundation, Uniformed Services University, Bethesda, MD, USA Purpose: The purpose of the present observational, feasibility study is to assess the preliminary safety and effectiveness of intranasal fentanyl for lumbar facet radiofrequency ablation procedures.Patients and methods: This cohort observational study included 23 adult patients. Systolic and diastolic blood pressures, heart rate, oxygen saturation percent, Pasero Opioid-Induced Sedation Scale score, and the Defense and Veterans Pain Rating Scale pain score were assessed prior to the procedure and intranasal fentanyl (100 μg administration and every 15 minutes after administration, up to 60 minutes post administration. Follow-up of patient satisfaction with pain control and treatment was assessed 24 hours after discharge. The primary outcome was safety as evidenced by adverse events. Secondary outcomes included the above-mentioned vital signs and pain ratings.Results: No adverse events occurred in the present study and all participants maintained an acceptable level of awareness throughout the assessment period. One-way repeated measures analyses of covariance tests with Bonferroni-adjusted means indicated that oxygen saturation, blood pressure, and heart rate changed from baseline, whereas pain scores were lower at post-administration levels compared with baseline. Finally, the majority of participants reported being satisfied with pain control and treatment

  9. Congenital absence of the lumbar facet joint associated with bilateral spondylolysis of the fifth lumbar vertebra.

    Science.gov (United States)

    Wang, Zhuo; Sakakibara, Toshihiko; Kasai, Yuichi

    2013-01-01

    A 14-year-old boy presented with a rare case of congenital absence of lumbar facet joint manifesting as low back pain. Physical examination showed no neurological or hematologic abnormalities. Radiography revealed absence of a facet joint on the right side of L4-5. Computed tomography and three-dimensional computed tomography revealed absence of the facet joint on the right side of L4-5 and spondylolysis on both sides of L5. Pain subsided after conservative treatment. This is an extremely rare case of congenital absence of lumbar facet joint associated with bilateral spondylolysis.

  10. Radiofrequency Denervation Improves Health-Related Quality of Life in Patients with Thoracic Zygapophyseal Joint Pain.

    Science.gov (United States)

    Hambraeus, Johan; Hambraeus, Kjerstin S; Persson, Jan

    2018-05-01

    To describe a practical approach for the diagnosis and treatment of thoracic zygapophyseal joint pain and to present preliminary clinical data on the effects of this treatment approach on health-related quality of life. An observational study. Specialist outpatient pain clinic in northern Sweden. Patients with long-term thoracic pain. We describe a method of radiofrequency denervation of thoracic zygapophyseal joints. We compared health-related quality of life between patients who underwent radiofrequency denervation of thoracic zygapophyseal joints and patients who underwent radiofrequency denervation for lumbar and cervical zygapophyseal joint pain. Treatment according to the Spine Intervention Society Guidelines was performed on the lumbar region in 178 patients and in the cervical region in 55 patients. Another 82 patients were treated in the thoracic region with our proposed technique. A survival plot of improvements in health-related quality of life revealed that all three treatments were effective in 65% or more of patients. The improvement in health-related quality of life was maintained for 12 or more months after treatment in 47% to 51% of patients. Our results suggest that radiofrequency denervation of thoracic zygapophyseal joint pain is as effective as radiofrequency denervation, the standard treatment, for lumbar and cervical zygapophyseal joint pain. If these results can be confirmed by other centers, radiofrequency denervation is likely to become more widely available for the treatment of thoracic zygapophyseal joint pain.

  11. Inter-rater reliability of diagnostic criteria for sacroiliac joint-, disc- and facet joint pain.

    Science.gov (United States)

    van Tilburg, Cornelis W J; Groeneweg, Johannes G; Stronks, Dirk L; Huygen, Frank J P M

    2017-01-01

    Several diagnostic criteria sets are described in the literature to identify low back pain subtypes, but very little is known about the inter-rater reliability of these criteria. We conducted a study to determine the reliability of diagnostic tests that point towards SI joint-, disc- or facet joint pain. Inter-rater reliability study alongside three randomized clinical trials. Multidisciplinary pain center of general hospital. Patients aged 18 or more with medical history and physical examination suggestive of sacroiliac joint-, disc- and facet joint pain on lumbar level. Making use of nowadays most common used diagnostic criteria, a physical examination is taken independently by three physicians (two pain physicians and one orthopedic surgeon). Inter-rater reliability (Kappa (κ) measure of agreement) and significance (p) between raters are presented. Strengths of agreement, indicated with κ values above 0,20, are presented in order of agreement. One hundred patients were included. None of the parameters from the physical investigation had κ values of more than 0.21 (fair) in all pairs of raters. Between two raters (C and D), there was an almost perfect agreement on three parameters, more specifically ``Abnormal sensory and motor examination, hyperactive or diminished reflexes'', ``Sitting exam shows no reflex, motor or sensory signs in the legs'' and ``Straight leg raising (Laségue) negative between 30 and 70 degrees of flexion''. The ``Drop test positive'' parameters had moderate strength of agreement between raters A and D and fair strength between raters A and B. The ``Digital interspinous pressure test positive'' had moderate strength of agreement between raters C and D and fair strength of agreement between raters A and B as well as raters B and C. Three other parameters had a fair strength of agreement between two raters, all other parameters had a slight or poor strength of agreement. Inter-rater reliability, confidence intervals and significance of

  12. Contribution of facet joints, axial compression, and composition to human lumbar disc torsion mechanics.

    Science.gov (United States)

    Bezci, Semih E; Eleswarapu, Ananth; Klineberg, Eric O; O'Connell, Grace D

    2018-02-12

    Stresses applied to the spinal column are distributed between the intervertebral disc and facet joints. Structural and compositional changes alter stress distributions within the disc and between the disc and facet joints. These changes influence the mechanical properties of the disc joint, including its stiffness, range of motion, and energy absorption under quasi-static and dynamic loads. There have been few studies evaluating the role of facet joints in torsion. Furthermore, the relationship between biochemical composition and torsion mechanics is not well understood. Therefore, the first objective of this study was to investigate the role of facet joints in torsion mechanics of healthy and degenerated human lumbar discs under a wide range of compressive preloads. To achieve this, each disc was tested under four different compressive preloads (300-1200 N) with and without facet joints. The second objective was to develop a quantitative structure-function relationship between tissue composition and torsion mechanics. Facet joints have a significant contribution to disc torsional stiffness (∼60%) and viscoelasticity, regardless of the magnitude of axial compression. The findings from this study demonstrate that annulus fibrosus GAG content plays an important role in disc torsion mechanics. A decrease in GAG content with degeneration reduced torsion mechanics by more than an order of magnitude, while collagen content did not significantly influence disc torsion mechanics. The biochemical-mechanical and compression-torsion relationships reported in this study allow for better comparison between studies that use discs of varying levels of degeneration or testing protocols and provide important design criteria for biological repair strategies. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Radiofrequency therapy in back pain and complex regional pain syndrome (CRPS

    Directory of Open Access Journals (Sweden)

    Norina Bergamin

    2011-01-01

    Full Text Available Percutaneous radiofrequency procedures are frequently used in the management of chronic pain. Continuous radiofrequency (CRF has been established as a safe and effective treatment for pain originating from facet and sacroiliac joints by way of co-agulation of their nerve supply. Different methods have been proposed to account for the complex nerve supply of the sacroiliac joint. Due to its neurodestructive property, CRF was limited to the treatment of neuropathic pain. When applied to the dorsal root ganglion (DRG for spinal pain or to the sympathetic ganglia in treatment of CRPS, heat related side effects have been reported. With the development of pulsed radiofrequency (PRF, a less destructive alternative to CRF became available, that is more suitable to treat neuropathic pain. PRF was adopted in the treatment of several pain conditions with different success. The results with PRF adjacent to the DRG are promising, whereas for facet and sacroiliac joint pain PRF could not yet be proven equally effective as CRF. As for PRF in CRPS there is almost no evidence available. The potential of PRF seems to lie in those areas where CRF is of limited value. Con-versely, it is questionable if PRF will ever be equally effective in indications, where CRF is already well established. Despite its active use in clinical practice, PRF is not validated yet nor is its mode of action. The literature in both cases is accumulating but further studies are urgently needed.

  14. Intra-articular nerve growth factor regulates development, but not maintenance, of injury-induced facet joint pain & spinal neuronal hypersensitivity.

    Science.gov (United States)

    Kras, J V; Kartha, S; Winkelstein, B A

    2015-11-01

    The objective of the current study is to define whether intra-articular nerve growth factor (NGF), an inflammatory mediator that contributes to osteoarthritic pain, is necessary and sufficient for the development or maintenance of injury-induced facet joint pain and its concomitant spinal neuronal hyperexcitability. Male Holtzman rats underwent painful cervical facet joint distraction (FJD) or sham procedures. Mechanical hyperalgesia was assessed in the forepaws, and NGF expression was quantified in the C6/C7 facet joint. An anti-NGF antibody was administered intra-articularly in additional rats immediately or 1 day following facet distraction or sham procedures to block intra-articular NGF and test its contribution to initiation and/or maintenance of facet joint pain and spinal neuronal hyperexcitability. NGF was injected into the bilateral C6/C7 facet joints in separate rats to determine if NGF alone is sufficient to induce these behavioral and neuronal responses. NGF expression increases in the cervical facet joint in association with behavioral sensitivity after that joint's mechanical injury. Intra-articular application of anti-NGF immediately after a joint distraction prevents the development of both injury-induced pain and hyperexcitability of spinal neurons. Yet, intra-articular anti-NGF applied after pain has developed does not attenuate either behavioral or neuronal hyperexcitability. Intra-articular NGF administered to the facet in naïve rats also induces behavioral hypersensitivity and spinal neuronal hyperexcitability. Findings demonstrate that NGF in the facet joint contributes to the development of injury-induced joint pain. Localized blocking of NGF signaling in the joint may provide potential treatment for joint pain. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Evaluation of the relationship between age, gender, and body mass index, and lumbar facet joint pain

    Directory of Open Access Journals (Sweden)

    Arman Taheri

    2016-01-01

    Full Text Available Introduction: Lumbar facet joint pain accounts for 5-15% of the cases of chronic, axial low back pain. Most commonly, facetogenic pain is the result of repetitive stress and/or cumulative low level trauma, leading to inflammation and stretching of the joint capsule. Patients and Methods: In this descriptive study 76 patients who were diagnosed, after a diagnostic block, as having lumbar facet joint pain were evaluated by their age, sex, and body mass index (BMI. Data were collected according to a checklist and entered to SPSS version 16. Results: The mean age of the participants was 48.53 years; the participants included 44 women and 32 men. Lumbar facet joint pain was more frequent in the age range of 40-55 years. With respect to BMI, lumbar facet joint pain was most frequently seen in patients with BMI of 24.5-29.5 kg/m 2 (40.8%. Conclusion: Based on our findings, the chances of developing lumbar facet joint pain is more in women who are between 40 years and 55 years of age and whose BMI is 24.5-29.5 kg/m 2 .

  16. Detailed examination of the lower cervical spine facet joints in a road traffic crash fatality - a case study

    DEFF Research Database (Denmark)

    Uhrenholt, Lars; Nielsen, Edith; Vesterby, Annie

    2005-01-01

    The lower cervical spine facet joints of a road traffic crash fatality were examined using diagnostic imaging and histological techniques. No injuries to the cervical spine facet joints could be identified with diagnostic imaging including conventional radiology, CT and MRI. Examination of stained...... histological sections visualised the morphology and integrity of the facet joints in detail. Occult injuries to and in close proximity of the cervical spine facet joints were identified only on histological examination....

  17. Delayed onset of a spinal epidural hematoma after facet joint injection

    Directory of Open Access Journals (Sweden)

    Mirko Velickovic

    2016-10-01

    Full Text Available The treatment of chronic back pain is a challenging problem. Facet joint infiltration is an established treatment for chronic low back pain caused by arthrosis of the lumbar facet joints. Due to the increasing number of patients with chronic low back pain, this therapy has become more frequent. We treated a 51-year-old male patient, who developed an epidural hematoma 2 months after infiltration therapy. Our case shows that even a delayed onset of spinal epidural hematoma is possible and should be kept in mind as a possible cause of acute myelopathy after spinal intervention.

  18. Qualitative and quantitative assessment of degeneration of cervical intervertebral discs and facet joints.

    Science.gov (United States)

    Walraevens, Joris; Liu, Baoge; Meersschaert, Joke; Demaerel, Philippe; Delye, Hans; Depreitere, Bart; Vander Sloten, Jos; Goffin, Jan

    2009-03-01

    Degeneration of intervertebral discs and facet joints is one of the most frequently encountered spinal disorders. In order to describe and quantify degeneration and evaluate a possible relationship between degeneration and biomechanical parameters, e.g., the intervertebral range of motion and intradiscal pressure, a scoring system for degeneration is mandatory. However, few scoring systems for the assessment of degeneration of the cervical spine exist. Therefore, two separate objective scoring systems to qualitatively and quantitatively assess the degree of cervical intervertebral disc and facet joint degeneration were developed and validated. The scoring system for cervical disc degeneration consists of three variables which are individually scored on neutral lateral radiographs: "height loss" (0-4 points), "anterior osteophytes" (0-3 points) and "endplate sclerosis" (0-2 points). The scoring system for facet joint degeneration consists of four variables which are individually scored on neutral computed tomography scans: "hypertrophy" (0-2 points), "osteophytes" (0-1 point), "irregularity" on the articular surface (0-1 point) and "joint space narrowing" (0-1 point). Each variable contributes with varying importance to the overall degeneration score (max 9 points for the scoring system of cervical disc degeneration and max 5 points for facet joint degeneration). Degeneration of 20 discs and facet joints of 20 patients was blindly assessed by four raters: two neurosurgeons (one senior and one junior) and two radiologists (one senior and one junior), firstly based on first subjective impression and secondly using the scoring systems. Measurement errors and inter- and intra-rater agreement were determined. The measurement error of the scoring system for cervical disc degeneration was 11.1 versus 17.9% of the subjective impression results. This scoring system showed excellent intra-rater agreement (ICC = 0.86, 0.75-0.93) and excellent inter-rater agreement (ICC = 0

  19. Sacroiliac joint pain: Prospective, randomised, experimental and comparative study of thermal radiofrequency with sacroiliac joint block.

    Science.gov (United States)

    Cánovas Martínez, L; Orduña Valls, J; Paramés Mosquera, E; Lamelas Rodríguez, L; Rojas Gil, S; Domínguez García, M

    2016-05-01

    To compare the analgesic effects between the blockade and bipolar thermal radiofrequency in the treatment of sacroiliac joint pain. Prospective, randomised and experimental study conducted on 60 patients selected in the two hospitals over a period of nine months, who had intense sacroiliac joint pain (Visual Analogue Scale [VAS]>6) that lasted more than 3 months. Patients were randomised into three groups (n=20): Group A (two intra-articular sacroiliac injections of local anaesthetic/corticosteroid guided by ultrasound in 7 days). Group B: conventional bipolar radiofrequency "palisade". Target points were the lateral branch nerves of S1, S2, and S3, distance needles 1cm. Group C: modified bipolar radiofrequency "palisade" (needle distance >1cm). Patients were evaluated at one month, three months, and one year. Demographic data, VAS reduction, and side effects of the techniques were assessed. One month after the treatment, pain reduction was >50% in the three groups PDolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    International Nuclear Information System (INIS)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W.

    2000-01-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  1. Pedicle marrow signal intensity changes in the lumbar spine: a manifestation of facet degenerative joint disease

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, J.L.; Kaplan, P.A.; Dussault, R.G.; Anderson, M.W. [Dept. of Radiology, Univ. of Virginia Health System, Charlottesville, VA (United States)

    2000-12-01

    Objective. Signal intensity changes in lumbar pedicles, similar to those described in vertebral body endplates adjacent to degenerated discs, have been described as an ancillary sign of spondylolysis on MRI. The purpose of this study was to determine whether pedicle marrow signal intensity changes also occur in association with facet degenerative joint disease.Design. Eighty-nine lumbar spine MRI examinations without spondylolysis were reviewed for marrow signal intensity changes in pedicles and vertebral bodies as well as for facet degenerative joint disease.Results. Five percent (46/890) of lumbar pedicles in 23 patients had marrow signal intensity changes. Ninety-one percent (42/46) of the abnormal pedicles had adjacent degenerative joint disease of the facets, while only 21% (189/890) of normal pedicles had adjacent facet degenerative joint disease (p<0.001). Eighty-nine percent (41/46) of the pedicles with marrow signal intensity changes had adjacent degenerative disc disease.Conclusions. Pedicle marrow signal intensity changes are not a specific sign of spondylolysis; they are commonly seen with adjacent facet degenerative joint disease in the absence of spondylolysis. Pedicle marrow signal intensity changes are probably a response to abnormal stresses related to abnormal motion or loading caused by the degenerative changes in the spinal segment. (orig.)

  2. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Gevargez, A.; Schirp, S.; Braun, M. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); Groenemeyer, D. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); EFMT Development and Research Center for Microtherapy, Bochum (Germany)

    2002-06-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  3. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    International Nuclear Information System (INIS)

    Gevargez, A.; Schirp, S.; Braun, M.; Groenemeyer, D.

    2002-01-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  4. Talocalcaneal Joint Middle Facet Coalition Resection With Interposition of a Juvenile Hyaline Cartilage Graft.

    Science.gov (United States)

    Tower, Dyane E; Wood, Ryan W; Vaardahl, Michael D

    2015-01-01

    Talocalcaneal joint middle facet coalition is the most common tarsal coalition, occurring in ≤2% of the population. Fewer than 50% of involved feet obtain lasting relief of symptoms after nonoperative treatment, and surgical intervention is commonly used to relieve symptoms, increase the range of motion, improve function, reconstruct concomitant pes planovalgus, and prevent future arthrosis from occurring at the surrounding joints. Several approaches to surgical intervention are available for patients with middle facet coalitions, ranging from resection to hindfoot arthrodesis. We present a series of 4 cases, in 3 adolescent patients, of talocalcaneal joint middle facet coalition resection with interposition of a particulate juvenile hyaline cartilaginous allograft (DeNovo(®) NT Natural Tissue Graft, Zimmer, Inc., Warsaw, IN). With a mean follow-up period of 42.8 ± 2.9 (range 41 to 47) months, the 3 adolescent patients in the present series were doing well with improved subtalar joint motion and decreased pain, and 1 foot showed no bony regrowth on a follow-up computed tomography scan. The use of a particulate juvenile hyaline cartilaginous allograft as interposition material after talocalcaneal middle facet coalition resection combined with adjunct procedures to address concomitant pes planovalgus resulted in good short-term outcomes in 4 feet in 3 adolescent patients. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of Water Content in Lumbar Intervertebral Discs and Facet Joints Before and After Physiological Loading Using T2 Mapping MRI.

    Science.gov (United States)

    Yamabe, Daisuke; Murakami, Hideki; Chokan, Kou; Endo, Hirooki; Oikawa, Ryosuke; Sawamura, Shoitsu; Doita, Minoru

    2017-12-15

    T2 mapping was used to quantify the water content of lumbar spine intervertebral discs (IVDs) and facet joints before and after physiological loading. The aim of this study was to clarify the interaction between lumbar spine IVD and facet joints as load-bearing structures by measuring the water content of their matrix after physiological loading using T2 mapping magnetic resonance imaging (MRI). To date, few reports have functionally evaluated lumbar spine IVD and facet joints, and their interaction in vivo. T2 mapping may help detect changes in the water content of IVD and articular cartilage of facet joints before and after physiological loading, thereby enabling the evaluation of changes in interacted water retention between IVD and facet joints. Twenty asymptomatic volunteers (10 female and 10 male volunteers; mean age, 19.3 years; age range, 19-20 years) underwent MRI before and after physiological loading such as lumbar flexion, extension, and rotation. Each IVD from L1/2 to L5/S1 was sliced at center of the disc space, and the T2 value was measured at the nucleus pulposus (NP), anterior annulus fibrosus (AF), posterior AF, and bilateral facet joints. In the NP, T2 values significantly decreased after exercise at every lumbar spinal level. In the anterior AF, there were no significant differences in T2 values at any level. In the posterior AF, T2 values significantly increased only at L4/5. In the bilateral facet joints, T2 values significantly decreased after exercise at every level. There was a significant decrease in the water content of facet joints and the NP at every lumbar spinal level after dynamic loading by physical lumbar exercise. These changes appear to play an important and interactional role in the maintenance of the interstitial matrix in the IVD NP and cartilage in the facet joint. 3.

  6. Lumbar facet joint fat pads: Their normal anatomy and their appearance when enlarged

    International Nuclear Information System (INIS)

    Taylor, J.R.; McCormick, C.C.

    1991-01-01

    The polar recesses, superior and inferior to lumbar facet joints, are filled by fat pads from which fat-filled synovial folds project between the articular surfaces for a distance of two to four millimetres. The intracapsular superior recess lies between the ligamentum flavum and the lamina above. The extracapsular inferior recess lies on the back of the lamina below and communicates with the joint through a hole in the inferior capsule. The intracapsular folds move freely in and out of the joint during movements. These features are demonstrated in anatomic studies using transverse sections and radiologic studies using computed tomography. In about 4% of lumbar spines examined, the intraarticular fat pads are enlarged and extend from the joint recess(es) into the middle third of one or more facet joints. The fat pads can be identified in CT scans by their radiolucency and distinguished from vacuum phenomenon by measuring their attenuation values. The cause of the intra-articular enlargement of the fat pads is unknown, but it is suggested that their extension into the middle third of the joint may be secondary to degenerative change in the motion segment with capsular laxity in the affected joint. (orig.)

  7. Histological Osteoarthritic Changes in the Human Cervical Spine Facet Joints Related to Age and Gender

    DEFF Research Database (Denmark)

    Uhrenholt, Lars; Charles, Annie Vesterby; Gregersen, Markil

    2018-01-01

    STUDY DESIGN: Cross-sectional autopsy study. OBJECTIVE: Quantify histological changes in the lower cervical spine facet joints with regard to age and gender using systematic random sampling of entire joints. SUMMARY OF BACKGROUND DATA: Neck pain is a common debilitating musculoskeletal condition...... and one of the highest ranked causes of years lived with disability. The cause of neck pain is multifactorial and osteoarthritis is one potential cause. The cervical spine facet joints have been implicated in the aetiology of chronic neck pain. Hence, a detailed description of their anatomy and age......- and gender related changes is needed. METHODS: The lower four cervical spine segments (C4-C7 included) were obtained from 72 subjects during autopsy; 29 females (median age 53 years [22-77]) and 43 males (median age 38 years [20-78]). A total of 1132 articular facets were embedded in toto in hard plastic...

  8. Radiofrequency denervation of the hip joint for pain management: case report and literature review.

    Science.gov (United States)

    Gupta, Gaurav; Radhakrishna, Mohan; Etheridge, Paul; Besemann, Markus; Finlayson, Robert J

    2014-01-01

    A 55-year-old male presented with severe pain and functional limitations as a result of left hip osteoarthritis. He had failed multiple treatments while waiting for a hip arthroplasty, including physical therapy, medications, and various intra-articular injections. Thermal radiofrequency lesioning of the obturator and femoral articular branches to the hip joint was offered in the interim. To our knowledge, this is the first report to describe an inferior-lateral approach for lesioning the obturator branch, the clinical application of successive lesions to increase denervation area, and outcomes in a patient receiving a second treatment with previously good results. To discuss relevant and technical factors for this specific case, we reviewed previous literature on hip joint radiofrequency and critically evaluated previous anatomic studies in the context of radiofrequency. The first treatment provided significant benefit for a period of 6 months. A second treatment was employed providing only mild to moderate benefit until his joint replacement surgery 4 months later. Literature review revealed studies of low quality secondary to small sample sizes, patient selection methodology, inclusion of patients with heterogenous etiologies for pain, variable needle placement techniques, and lack of measurement of functional outcomes. Case report and low quality studies in existing literature. Hip joint radiofrequency denervation is a promising avenue for adjunctive treatment of hip pain. Further cadaveric studies are required to clarify a multitude of technical parameters. Once these are well defined, future clinical studies should consider pain, functional, and economic outcomes in their design.

  9. A Best-Evidence Systematic Appraisal of the Diagnostic Accuracy and Utility of Facet (Zygapophysial) Joint Injections in Chronic Spinal Pain.

    Science.gov (United States)

    Boswell, Mark V; Manchikanti, Laxmaiah; Kaye, Alan D; Bakshi, Sanjay; Gharibo, Christopher G; Gupta, Sanjeeva; Jha, Sachin Sunny; Nampiaparampil, Devi E; Simopoulos, Thomas T; Hirsch, Joshua A

    2015-01-01

    Spinal zygapophysial, or facet, joints are a source of axial spinal pain and referred pain in the extremities. Conventional clinical features and other noninvasive diagnostic modalities are unreliable in diagnosing zygapophysial joint pain. A systematic review of the diagnostic accuracy of spinal facet joint nerve blocks. To determine the diagnostic accuracy of spinal facet joint nerve blocks in chronic spinal pain. A methodological quality assessment of included studies was performed using Quality Appraisal of Reliability Studies (QAREL). Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. The level of evidence was classified as Level I to V based on the grading of evidence utilizing best evidence synthesis. Data sources included relevant literature identified through searches of PubMed and other electronic searches published from 1966 through March 2015, Cochrane reviews, and manual searches of the bibliographies of known primary and review articles. Studies must have been performed utilizing controlled local anesthetic blocks. The criterion standard must have been at least 50% pain relief from baseline scores and the ability to perform previously painful movements. The available evidence is Level I for lumbar facet joint nerve blocks with the inclusion of a total of 17 studies with dual diagnostic blocks, with at least 75% pain relief with an average prevalence of 16% to 41% and false-positive rates of 25% to 44%. The evidence for diagnosis of cervical facet joint pain with cervical facet joint nerve blocks is Level II based on a total of 11 controlled diagnostic accuracy studies, with significant variability among the prevalence in a heterogenous population with internal inconsistency. The prevalence rates ranged from 36% to 67% with at least 80% pain relief as the criterion standard and a false-positive rate of 27% to 63%. The level of evidence for the diagnostic accuracy of thoracic facet

  10. MR-guided facet joint injection therapy using an open 1.0-T MRI system: an outcome study

    International Nuclear Information System (INIS)

    Freyhardt, Patrick; Bucourt, Maximilian de; Maurer, Martin; Renz, Diane; Gebauer, Bernhard; Hamm, Bernd; Streitparth, Florian; Hartwig, Tony; Teichgraeber, Ulf K.M.

    2013-01-01

    To evaluate the accuracy, safety and efficacy of magnetic resonance imaging (MRI)-guided facet joint injection therapy using a 1.0-T open MRI. One hundred and sixty-six facet joint blocks in 45 patients with lower back pain were performed under MR fluoroscopic guidance using a proton-density-weighted turbo-spin-echo sequence. An in-room monitor, wireless MR-mouse for operator-controlled multiplanar navigation, a flexible surface coil and MR-compatible 20-G needle were used. Clinical outcome was evaluated by questionnaire before intervention and after 1 week, 3, 6 and 12 months using a numerical visual analogue scale (VAS). All facet joint blocks were considered technically successful with distribution of the injectant within and/or around the targeted facet joint. No major complications occurred. The final outcome analysis included 38 patients. An immediate effect was reported by 63 % of the patients. A positive mid-/long-term effect was seen in 13 patients (34 %) after 6 months and in 9 patients (24 %) after 12 months. Mean VAS was reduced from 7.1 ± 1.7 (baseline) to 3.5 ± 2.2, 4.1 ± 3.0, 3.8 ± 2.9 and 4.6 ± 2.9 at 1 week, 3, 6 and 12 months (P < 0.01). MR-guided facet joint injection therapy of the lumbosacral spine is accurate, safe and efficient in the symptomatic treatment of lower back pain. (orig.)

  11. Desmoid type fibromatosis in the facet joint of lumbar spine: Case report and review of literature

    Energy Technology Data Exchange (ETDEWEB)

    Kim, So Jung; Ha, Doo Hoe; Lee, Sang Min; Kang, Hae Youn [CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2013-10-15

    Desmoid type fibromatosis is a benign fibroblastic tumor arising from the fascia or musculoaponeurosis. It may occur in various locations, but most commonly in the shoulder girdle and neck; to our knowledge, there has been no reported case originating from a facet joint of the spine. We report CT and MR imaging findings of a desmoid type fibromatosis, involving the facet joint of the L3-4 spine with bone involvement.

  12. Association between facet joint osteoarthritis and the Oswestry Disability Index.

    Science.gov (United States)

    Maataoui, Adel; Vogl, Thomas J; Middendorp, Marcus; Kafchitsas, Konstantinos; Khan, M Fawad

    2014-11-28

    To investigate the correlation of facet joint osteoarthritis (FJOA) at lumbar levels L4/L5 and L5/S1 and the Oswestry Disability Index (ODI). The study involved lumbar MRIs of 591 patients with a mean age of 47.3 years. The MRIs of the lumbar spine were performed on a 1.5 Tesla scanner (Magnetom(®) Avanto, Siemens AG, Erlangen, Germany) using a dedicated receive only spine coil. After initial blinding, each dataset was evaluated by 2 board certified radiologist with more than 5 years experience in musculoskeletal imaging. In total 2364 facet joints were graded. Degenerative changes of the facet joints were evaluated according to the 4-point scale as proposed by Weishaupt et al Functional status was assessed using the ODI. The index is scored from 0 to 100 and interpreted as follows: 0%-20%, minimal disability; 20%-40%, moderate disability; 40%-60%, severe disability; 60%-80%, crippled; 80%-100%, patients are bedbound. Spearman's coefficient of rank correlation was used for statistical analysis, with significance set at P disability had a minimum of 0% and a maximum of 91.11% with an arithmetic mean of 32.77% ± 17.02%. The majority of patients (48.39%) had moderate functional disability (21%-40%). There was no significant correlation between FJOA and ODI on both sides of lumbar level L4/5 and on the left side of lumbar level L5/S1. A weak positive correlation was evaluated between ODI and FJOA on the right side of lumbar level L5/S1. The missing correlation of FJOA and ODI confirms our clinical experience that imaging alone is an insufficient approach explaining low back pain. Clinical correlation is imperative for an adequate diagnostic advance in patients with low back pain.

  13. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain.

    Science.gov (United States)

    Biswas, Binay Kumar; Dey, Samarjit; Biswas, Saumya; Mohan, Varinder Kumar

    2016-01-01

    Sacroiliac (SI) joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF) neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10) with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18 th -month follow-up, he is pain free except for mild pain (NRS 2/10) on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  14. Water-cooled radiofrequency neuroablation for sacroiliac joint dysfunctional pain

    Directory of Open Access Journals (Sweden)

    Binay Kumar Biswas

    2016-01-01

    Full Text Available Sacroiliac (SI joint dysfunction is a common source of chronic low-back pain. Recent evidences from different parts of the world suggest that cooled radiofrequency (RF neuroablation of sacral nerves supplying SI joints has superior pain alleviating properties than available existing treatment options for SI joint dysfunctional pain. A 35-year-old male had intractable bilateral SI joint pain (numeric rating scale [NRS] - 9/10 with poor treatment response to intra-articular steroid therapy. Bilateral water cooled = RF was applied for neuroablation of nerves supplying both SI joints. Postprocedure pain intensity was 5/10 and after 7 days it was 2/10. On 18th-month follow-up, he is pain free except for mild pain (NRS 2/10 on occasional extreme twisting of the back. This case attempts to highlight that sacral neuroablation based on cooled RF technique can be a long lasting remedial option for chronic SI joint pain unresponsive to conventional treatment.

  15. The possibility of the radiological and ultrasonographic examination of the facet joints of the equine thoracic and lumbar spine

    International Nuclear Information System (INIS)

    Reisinger, R.

    2003-03-01

    The facet joints of the equine thoracic and lumbar spine were examined by radiology and ultrasonography in 31 and 20 standing horses, respectively. The employed methods were evaluated. The left and right joints of 15/31 standing horses were comparatively x-rayed with both 20 o ventral oblique and 30 o dorsal oblique techniques. The independent evaluation of the ensuing films by four experienced veterinary surgeons yielded a significantly better assessment of the tested parameters in the 20 o ventral oblique technique. It was possible to depict the facet joints of the right and left sides between the caudal margin of the scapula and the diaphragm with the pulmonary field as background rich in contrast. In 20 horses, the facet joints were examined from Th10 to L6 in longitudinal and sagittal planes. A linear-array ultrasound probe with a frequency of 7,5 MHz and a convex ultrasound probe with a frequency of 3,5 MHz were used. Depending on the nutritional state, the soft tissue structures could be evaluated. The evaluation of the facet joints themselves was very limited. (author)

  16. Single strip lesions radiofrequency denervation for treatment of sacroiliac joint pain: two years' results.

    Science.gov (United States)

    Bellini, Martina; Barbieri, Massimo

    2016-01-01

    Sacroiliac joint pain can be managed by intra-articular injections or radiofrequency of its innervation. Single strip lesions radiofrequency denervation is a new system. The objective of this study was to present one of the first utilizations of this innovative technique. 60 patients who met the diagnostic criteria for sacroiliac joint syndrome were enrolled in the study. In total, 102 single strip lesions radiofrequency denervations were performed. Pain intensity was measured with the Oswestry low back pain disability questionnaire and the Oswestry Disability Index whose scores were assessed at 1, 3, 6 and 12 months after the procedure. 91.8 % of the 102 radiofrequency treatments resulted in a reduction of more than 50% pain intensity relief at 1 month, 81.6% at 3 months and 59.16% at 6 months. In 35.7% of cases, the relief was continuative up to 1 year. No relief was observed in 12.24% of cases. The ODI scores improved significantly 1 month after the procedure, compared with the baseline scores. The ODI scores after 6 months improved very clearly compared with the baseline scores and with the 3-month scores. Single strip lesions radiofrequency denervation using the Simplicity III probe is a potential modality for intermediate term relief for patients with sacroiliac pain.

  17. Fluoroscopy-guided intrA-articular facet joint steroid injection for the management of low back pain: Therapeutic effectiveness and arthrographic pattern

    International Nuclear Information System (INIS)

    Kim, Su Jin; Lee, Jun Woo; Lee, Guen Young; You, Ja Yeon; Kang, Heung Sik; Chai, Jae Won; Ahn, Joong Mo

    2015-01-01

    To evaluate the effectiveness of fluoroscopy-guided intra-articular facet joint steroid injection for the management of low back pain, and to document the incidence of epidural leakage. In total, 320 facet joint injections of 244 consecutive patients were included in this study. All patients had undergone an intra-articular facet joint steroid injection in 2007 and had follow-up post-treatment medical records. The response to treatment was analyzed on the basis of chart documentation (aggravated, no change, slightly improved, much improved, no pain). Fluoroscopic arthrograms of the injections were retrospectively analyzed by two radiologists. Of the 244 patients, 85.2% (n = 208) showed improvement after an initial intra-articular facet joint steroid injection. A total of 77.9% (n = 162) of the patients showed symptom recurrence, with a median of a 69 day symptom-free interval, while 30.3% (n = 74) of the patients showed symptom-free intervals of more than six months. Overall, 74 (33.3%) of the 222 cases of intra-articular facet joint steroid injections without concomitant epidural steroid injection showed epidural leakage in fluoroscopic arthrograms. Fluoroscopy-guided intra-articular facet joint injection is a reliable technique for the management of low back pain, with excellent immediate effectiveness and good prolonged (> 2 months) pain relief. Epidural leakage during injection was detected in one-third of the cases

  18. Fluoroscopy-guided intrA-articular facet joint steroid injection for the management of low back pain: Therapeutic effectiveness and arthrographic pattern

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Jin; Lee, Jun Woo; Lee, Guen Young; You, Ja Yeon; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Chai, Jae Won [Dept. of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Ahn, Joong Mo [Dept. of Radiology, University of Pittsburgh Medical Center, Pittsburgh (United States)

    2015-09-15

    To evaluate the effectiveness of fluoroscopy-guided intra-articular facet joint steroid injection for the management of low back pain, and to document the incidence of epidural leakage. In total, 320 facet joint injections of 244 consecutive patients were included in this study. All patients had undergone an intra-articular facet joint steroid injection in 2007 and had follow-up post-treatment medical records. The response to treatment was analyzed on the basis of chart documentation (aggravated, no change, slightly improved, much improved, no pain). Fluoroscopic arthrograms of the injections were retrospectively analyzed by two radiologists. Of the 244 patients, 85.2% (n = 208) showed improvement after an initial intra-articular facet joint steroid injection. A total of 77.9% (n = 162) of the patients showed symptom recurrence, with a median of a 69 day symptom-free interval, while 30.3% (n = 74) of the patients showed symptom-free intervals of more than six months. Overall, 74 (33.3%) of the 222 cases of intra-articular facet joint steroid injections without concomitant epidural steroid injection showed epidural leakage in fluoroscopic arthrograms. Fluoroscopy-guided intra-articular facet joint injection is a reliable technique for the management of low back pain, with excellent immediate effectiveness and good prolonged (> 2 months) pain relief. Epidural leakage during injection was detected in one-third of the cases.

  19. Efetividade da rizotomia facetária por radiofrequência na lombalgia mecânica crônica Efectividad de la rizotomía facetaria en lumbago mecánico Effectiveness of radiofrequency facet rhizotomy in the treatment of mechanical back pain

    Directory of Open Access Journals (Sweden)

    Lourimar Octaviano de Tolêdo

    2011-01-01

    Full Text Available OBJETIVO: Avaliar a efetividade da rizotomia facetária lombar por radiofreqüência no tratamento da dor lombar mecânica. MÉTODOS: Estudo prospectivo de 23 pacientes tratados com rizotomia por radiofrequência devido à dor lombar mecânica. O registro da intensidade da dor foi medido através de pontuação pela escala visual analógica (EVA e o número de analgésicos administrado a cada paciente no pré-operatório e nos controles de 3, 6 e 12 meses de pós-operatórios. RESULTADOS: Foi observado um declínio significativo da intensidade da dor (p OBJETIVO: Evaluar la efectividad de la rizotomía por radiofrecuencia facetaria lumbar en el tratamiento del lumbago mecánico. MÉTODOS: Estudio prospectivo de 23 pacientes tratados con rizotomía por radiofrecuencia en lumbago mecánico. El registro de la intensidad del dolor se midió por la puntuación de la escala analógica visual (VAS y el número de analgésicos administrados a cada paciente antes de la operación, y 3, 6 y 12 meses después de la intervención. RESULTADOS: Se observó una disminución significativa en la intensidad del dolor (p OBJECTIVE: To evaluate the effectiveness of radiofrequency lumbar facet rhizotomy in the treatment of mechanical low back pain. METHODS: Prospective study of 23 patients treated with radiofrequency rhizotomy in mechanical low back pain. The pain intensity was measured by the visual analog scale (VAS and the number of analgesics administered for each patient preoperatively and 3, 6 and 12 months postoperatively. RESULTS: We observed a significant decline in pain intensity (p<0.0001 in patients. CONCLUSIONS: In the series of patients assessed the treatment was effective in relieving symptoms of mechanical low back pain and the use of analgesics after the procedure was lower.

  20. Up-regulation of p55 TNF alpha-receptor in dorsal root ganglia neurons following lumbar facet joint injury in rats.

    Science.gov (United States)

    Sakuma, Yoshihiro; Ohtori, Seiji; Miyagi, Masayuki; Ishikawa, Tetsu; Inoue, Gen; Doya, Hideo; Koshi, Takana; Ito, Toshinori; Yamashita, Masaomi; Yamauchi, Kazuyo; Suzuki, Munetaka; Moriya, Hideshige; Takahashi, Kazuhisa

    2007-08-01

    The rat L5/6 facet joint is multisegmentally innervated from the L1 to L6 dorsal root ganglia (DRG). Tumor necrosis factor (TNF) is a known mediator of inflammation. It has been reported that satellite cells are activated, produce TNF and surround DRG neurons innervating L5/6 facet joints after facet injury. In the current study, changes in TNF receptor (p55) expression in DRG neurons innervating the L5/6 facet joint following facet joint injury were investigated in rats using a retrograde neurotransport method followed by immunohistochemistry. Twenty rats were used for this study. Two crystals of Fluorogold (FG; neurotracer) were applied into the L5/6 facet joint. Seven days after surgery, the dorsal portion of the capsule was cut in the injured group (injured group n = 10). No injury was performed in the non-injured group (n = 10). Fourteen days after the first application of FG, bilateral DRGs from T13 to L6 levels were resected and sectioned. They were subsequently processed for p55 immunohistochemistry. The number of FG labeled neurons and number of FG labeled p55-immunoreactive (IR) neurons were counted. FG labeled DRG neurons innervating the L5/6 facet joint were distributed from ipsilateral L1 to L6 levels. Of FG labeled neurons, the ratio of DRG neurons immunoreactive for p55 in the injured group (50%) was significantly higher than that in the non-injured group (13%). The ratio of p55-IR neurons of FG labeled DRG neurons was significantly higher in total L1 and L2 DRGs than that in total L3, 4, 5 and 6 DRGs in the injured group (L1 and 2 DRG, 67%; L3, 4, 5 and 6 DRG, 37%, percentages of the total number of p55-IR neurons at L1 and L2 level or L3-6 level/the total number of FG-labeled neurons at L1 and L2 level or L3-6 level). These data suggest that up-regulation of p55 in DRG neurons may be involved in the sensory transmission from facet joint injury. Regulation of p55 in DRG neurons innervating the facet joint was different between upper DRG innervated

  1. Imaging findings predicting the outcome of cervical facet joint blocks

    International Nuclear Information System (INIS)

    Hechelhammer, Lukas; Pfirrmann, Christian W.A.; Zanetti, Marco; Hodler, Juerg; Schmid, Marius R.; Boos, Norbert

    2007-01-01

    To determine which cross-sectional imaging findings predict the short-term outcome of cervical facet joint blocks (FJB) and to evaluate the effect of combined intra-/periarticular versus periarticular injection on pain. Fifty facet joints in 37 patients were included in the study. Single, unilateral FJBs in 24 patients, and bilateral single level FJBs in 13 patients were performed, respectively. In all patients, pain relief was assessed using a visual analogue scale. All computed tomography (CT) examinations were blindly reviewed by two radiologists. Osteoarthritis was rated using the Kellgren classification. The presence of combined intra-/periarticular vs. sole periarticular injection of contrast was evaluated. Kellgren Grades 0 (n=23), 1 (n=5), 2 (n=3), 3 (n=9), and 4 (n=10) were found. Mean pain relief after injection was 35% (range: 0-100%). 40% of all injections were combined intra-/periarticular. There was neither a statistically significant difference between pain relief and combined intra-/periarticular versus sole periarticular injection (p=0.64) nor the grade of osteoarthritis (p=0.49). Pain relief after cervical FJBs does not correlate with morphologic alterations seen on CT. Periarticular FJBs are not less successful than combined intra-/periarticular FJBs. (orig.)

  2. Pulsed Radiofrequency Application for the Treatment of Pain Secondary to Sacroiliac Joint Metastases

    OpenAIRE

    Yi, Yu Ri; Lee, Na Rea; Kwon, Young Suk; Jang, Ji Su; Lim, So Young

    2016-01-01

    Sacroiliac (SI) joint pain can result from degeneration, infection, malignancy, and trauma. Patients with metastatic bone pain who do not respond to conventional treatment may need more aggressive neuroinvasive approaches. Recently, pulsed radiofrequency (PRF) neuromodulation has emerged as a promising treatment alternative for refractory cases of SI joint pain. Nevertheless, there is no report on the treatment of pain arising from SI joint metastases with PRF. We are reporting about a 63-yea...

  3. Rotatory Subluxation and Facet Deformity in the Atlanto-occipital Joint in Patients with Chronic Atlantoaxial Rotatory Fixation: Two Case Reports.

    Science.gov (United States)

    Kashii, Masafumi; Masuhara, Kenta; Kaito, Takashi; Iwasaki, Motoki

    2017-01-01

    The relationship between the morphometry of atlantoaxial joint and chronic atlantoaxial rotatory fixation (AARF) is well known, but disorders in the atlanto-occipital joint in chronic AARF are not fully elucidated. The authors report two rare cases of secondary deformities in the atlanto-occipital joint in chronic AARF. Two patients with chronic AARF were treated with closed manipulation, skull traction and halo-vest immobilization. Clinical outcomes and radiographs were reviewed retrospectively, focusing on pathological changes in the atlanto-occipital joint using multiplanar reconstruction computed tomography and three-dimensional computed tomography images. Case 1 (12-year-old girl) had rotatory subluxation with a superior facet deformity of the atlas in the atlanto-occipital joint before the initiation of treatment. After a series of conservative treatments, both atlantoaxial and atlanto-occipital rotatory fixation could not be reduced, and both the superior facet deformity of the atlas and osteoarthritic changes in the atlanto-occipital developed. She was monitored without surgery because the disorder progressed to the spontaneous fusion of the occipital bone to the axis. Case 2 (13-year-old boy) had rotatory subluxation without facet deformity of the atlas in the atlanto-occipital joint before the initiation of treatment. However, both the superior facet deformity of the atlas and osteoarthritic changes in the atlanto-occipital developed over time, and both atlantoaxial and atlanto-occipital rotatory fixation could not be reduced after a series of conservative treatments. He still had severe neck pain and severely restricted neck mobility and underwent spinal fusion. Atlanto-occipital rotatory subluxation and facet deformity in the atlanto-occipital joint may occur after prolonged AARF. It is necessary to pay attention to pathological changes not only in the atlantoaxial joint but also in the atlanto-occipital joint, when orthopedic surgeons treat patients

  4. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate

  5. [Application of radiofrequency vaporization in arthroscopic treatment of patellofemoral joint disorders].

    Science.gov (United States)

    Xuan, Tao; Xu, Bin; Xu, Honggang; Wang, Hao

    2009-01-01

    To explore the treatment of patellofemoral joint disorders with radiofrequency vaporization under arthroscopy. From June 2004 to June 2007, 86 cases of patellofemoral joint disorder (98 knees) were treated by lateral retinacular release or medial retinacular tighten added, and combined with bipolar radiofrequency chondroplasty under arthroscopy. There were 30 males (34 knees) and 56 females (64 knees), aging 15-68 years (mean 40 years). The locations were left in 42 cases, right in 32 cases, both sides in 12 cases. The disease course was 3 months to 6 years (mean 30.5 months). In 98 knees, there were 28 knees of static patellar tilt, 10 knees of static patellar subluxation, 45 knees of dynamic patellar tilt and 15 knees of dynamic patellar subluxation. The Lysholm knee score preoperatively was 57.72 +/- 8.86. The patellofemoral cartilage abnormality were classified according to the Outerbridge grade (18 knees of grade I, 36 knees of grade II, 32 knees of grade III and 12 knees of grade IV). The incisions healed by first intention without complications such as infection or hemarthrosis. Seventy-five cases (82 knees) were followed up 8-37 months (mean 20.6 months). One month after operation, the patellofemoral joint pain was relieved remarkably, the knee joint activity was good and the radiological outcomes was also satisfactory. Six months after operation, the Lysholm knee score was improved significantly in patients of grades I, II and III (P 0.05). The postoperative score was 69.95 +/- 5.42 (P joint disorders.

  6. A New Technique for the Treatment of Lumbar Facet Joint Syndrome Using Intra-articular Injection with Autologous Platelet Rich Plasma.

    Science.gov (United States)

    Wu, Jiuping; Du, Zhenwu; Lv, Yang; Zhang, Jun; Xiong, Wei; Wang, Ruiqiang; Liu, Rui; Zhang, Guizhen; Liu, Qinyi

    2016-01-01

    Lumbar facet joint syndrome is currently suggested to be a main source of axial low back pain, and a large portion of axial low back pain is caused by disorders in lumbar facet joints. Intra-articular injection is one of the most common treatment methods in the early clinical application. Therefore, we attempt to seek a new injectable material, autologous platelet rich plasma (PRP), to treat lumbar facet syndrome, as well as to assess its therapeutic effectiveness and safety. A prospective clinic evaluation. The outpatient clinic of a single academic medical center. Total 19 patients with lumbar facet joint syndrome (8 men, 11 women; mean ages: 52.53 ± 6.79 years, range: 38 - 62 years) were enrolled to receive lumbar facet joint injection with autologous PRP under x-ray fluoroscopic control. Patients were followed up immediately, at one week, one month, 2 months, and 3 months following treatment, and the elements of this analysis included low back pain visual analogue scale (VAS) at rest and during flexion, Roland-Morris Disability Questionnaire (RMQ), Oswestry Disability Index (ODI), and modified MacNab criteria for the pain relief. All the 19 patients completed the intra-articular injections with autologous PRP successfully. At one week after treatment, low back pain reduced significantly compared with prior to treatment both at rest and during flexion. The outcomes were assessed as "good" or "excellent" for 9 patients (47.37%) immediately after treatment, 14 patients (73.68%) at one week, 15 patients (78.95%) at one month, 15 patients (78.95%) at 2 months, and 15 patients (78.95%) at 3 months. Statistically significant differences were observed based on RMQ and a more than 10% improvement in lumbar functional capacity was observed based on ODI between pre-treatment and post-treatment. In addition, there were no severe relevant complications during the whole process of injection and follow-up period. A control group and the curative effect observations with

  7. Assessment of trunk muscle density using CT and its association with degenerative disc and facet joint disease of the lumbar spine.

    Science.gov (United States)

    Sebro, Ronnie; O'Brien, Liam; Torriani, Martin; Bredella, Miriam A

    2016-09-01

    The purpose of this study was (1) to evaluate the association of trunk muscle density assessed by computed tomography (CT) with age, gender, and BMI and (2) to evaluate the association between trunk muscle CT density and degenerative disc and facet joint disease of the lumbar spine. The study was IRB approved and HIPAA compliant. The study group comprised 100 subjects (mean age 44.4 ± 22.2 years, 51 % male) who underwent CT of the abdomen and pelvis without intravenous contrast. Exclusion criteria included prior abdominal or spine surgery, active malignancy and scoliosis. CTs were reviewed and the attenuation of the rectus abdominis, transverse abdominis, internal and external obliques, psoas, multifidus, longissimus and gluteus maximus were measured bilaterally at consistent levels. Degenerative disc and bilateral facet joint disease were scored using established methods. Univariate analyses were performed using linear regression. Multivariate linear regression was performed to adjust for age, gender and BMI. CT density of each trunk muscle correlated inversely with age (p degenerative disc and facet joint disease in the univariate analyses (p degenerative disc and facet joint disease respectively in the multivariate analysis. Fatty infiltration of trunk musculature increases with age and BMI. Fatty infiltration of the gluteus maximus and transverse abdominis are associated with degenerative disc and facet joint disease, independent of age, gender and BMI.

  8. Comparative Analysis of Bone Structural Parameters Reveals Subchondral Cortical Plate Resorption and Increased Trabecular Bone Remodeling in Human Facet Joint Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Cordula Netzer

    2018-03-01

    Full Text Available Facet joint osteoarthritis is a prominent feature of degenerative spine disorders, highly prevalent in ageing populations, and considered a major cause for chronic lower back pain. Since there is no targeted pharmacological therapy, clinical management of disease includes analgesic or surgical treatment. The specific cellular, molecular, and structural changes underpinning facet joint osteoarthritis remain largely elusive. The aim of this study was to determine osteoarthritis-related structural alterations in cortical and trabecular subchondral bone compartments. To this end, we conducted comparative micro computed tomography analysis in healthy (n = 15 and osteoarthritic (n = 22 lumbar facet joints. In osteoarthritic joints, subchondral cortical plate thickness and porosity were significantly reduced. The trabecular compartment displayed a 42 percent increase in bone volume fraction due to an increase in trabecular number, but not trabecular thickness. Bone structural alterations were associated with radiological osteoarthritis severity, mildly age-dependent but not gender-dependent. There was a lack of association between structural parameters of cortical and trabecular compartments in healthy and osteoarthritic specimens. The specific structural alterations suggest elevated subchondral bone resorption and turnover as a potential treatment target in facet joint osteoarthritis.

  9. Radiofrequency sensory ablation as a treatment for symptomatic unilateral lumbosacral junction pseudarticulation (Bertolotti's syndrome): a case report.

    Science.gov (United States)

    Burnham, Robert

    2010-06-01

    Describe the clinical presentation, diagnostic evaluation, and successful treatment of a case of symptomatic unilateral lumbosacral junction pseudarticulation using a novel radiofrequency nerve ablation technique. A 56-year-old female patient who had suffered with low back and right upper buttock pain for 16 years experienced incomplete relief with L4/5 facet joint radiofrequency ablation. She was found to have an elongated right L5 transverse process that articulated with the sacral ala (Bertolotti's syndrome). Fluoroscopically guided local anesthetic/corticosteroid injection into the pseudarthrosis eliminated her residual right buttock pain for the duration of the local anesthetic only. Complete pain relief was achieved by injecting local anesthetic circumferentially around the posterior pseudarthrosis articular margin. Accordingly, bipolar radiofrequency strip thermal lesions were created at the same locations. Complete pain relief and full restoration of function was achieved for 16 months postprocedure. This case report describes a novel radiofrequency technique for treating symptomatic lumbosacral junction pseudarticulation that warrants further evaluation.

  10. CT-guided intradiscal ozone injection combined with intervertebral facet joint steroid injection for lumbar disk herniation accompanied with intervertebral arthritis

    International Nuclear Information System (INIS)

    Zhang Li; Chen Zhaohui; Sun Xijun; Liu Jianping; Li Jiakai

    2009-01-01

    Objective: To compare the clinical effectiveness of ozone (O 3 ) nucleus pulposus ablation only with that of O 3 nucleus pulposus ablation combined with intervertebral facet joint injection of compound Betamethasome in treating lumbar disk herniation accompanied with intervertebral facet arthritis. Methods: Eighty patients with lumbar disk herniation and intervertebral facet arthritis were equally and randomly divided into two groups. Under CT guidance, O 3 nucleus pulposus ablation was performed in patients of group A(n=40), while O 3 nucleus pulposus ablation combined with intervertebral facet joint injection of compound Betamethasome (0.5-1 ml) was carried out in patients of group B(n=40). Using double blind method the therapeutic effectiveness was evaluated before and 1 week,3,6-months after the procedure by an Oswestry Low Back Pain Disability Questionnaire. Results: One week after the procedure the effective rate of group A and group B was 65% and 82.5% respectively. Three and six months after the treatment, the effective rate was 75% and 70% respectively for group A, while it was 90% and 92.5% respectively for group B. The difference between two groups was significant (P 3 combined with intervertebral facet joint injection of compound Betamethasome is an effective and safe treatment for lumbar disk herniation accompanied with intervertebral facet arthritis.It is worth popularizing this technique in clinical practice. (authors)

  11. Lumbar disc degeneration was not related to spine and hip bone mineral densities in Chinese: facet joint osteoarthritis may confound the association.

    Science.gov (United States)

    Pan, Jianjiang; Lu, Xuan; Yang, Ge; Han, Yongmei; Tong, Xiang; Wang, Yue

    2017-12-01

    A sample of 512 Chinese was studied and we observed that greater disc degeneration on MRI was associated with greater spine DXA BMD. Yet, this association may be confounded by facet joint osteoarthritis. BMD may not be a risk factor for lumbar disc degeneration in Chinese. Evidence suggested that lumbar vertebral bone and intervertebral disc interact with each other in multiple ways. The current paper aims to determine the association between bone mineral density (BMD) and lumbar disc degeneration using a sample of Chinese. We studied 165 patients with back disorders and 347 general subjects from China. All subjects had lumbar spine magnetic resonance (MR) imaging and dual- energy X-ray absorptiometry (DXA) spine BMD studies, and a subset of general subjects had additional hip BMD measurements. On T2-weighted MR images, Pfirrmann score was used to evaluate the degree of lumbar disc degeneration and facet joint osteoarthritis was assessed as none, slight-moderate, and severe. Regression analyses were used to examine the associations between lumbar and hip BMD and disc degeneration, adjusting for age, gender, body mass index (BMI), lumbar region, and facet joint osteoarthritis. Greater facet joint osteoarthritis was associated with greater spine BMD (P osteoarthritis entered the regression model, however, greater spine BMD was associated with greater facet joint osteoarthritis (P  0.05). No statistical association was observed between spine BMD and lumbar disc degeneration in patients with back disorders (P > 0.05), and between hip BMD and disc degeneration in general subjects (P > 0.05). BMD may not be a risk factor for lumbar disc degeneration in Chinese. Facet joint osteoarthritis inflates DXA spine BMD measurements and therefore, may confound the association between spine BMD and disc degeneration.

  12. Assessment of trunk muscle density using CT and its association with degenerative disc and facet joint disease of the lumbar spine

    International Nuclear Information System (INIS)

    Sebro, Ronnie; O'Brien, Liam; Torriani, Martin; Bredella, Miriam A.

    2016-01-01

    The purpose of this study was (1) to evaluate the association of trunk muscle density assessed by computed tomography (CT) with age, gender, and BMI and (2) to evaluate the association between trunk muscle CT density and degenerative disc and facet joint disease of the lumbar spine. The study was IRB approved and HIPAA compliant. The study group comprised 100 subjects (mean age 44.4 ± 22.2 years, 51 % male) who underwent CT of the abdomen and pelvis without intravenous contrast. Exclusion criteria included prior abdominal or spine surgery, active malignancy and scoliosis. CTs were reviewed and the attenuation of the rectus abdominis, transverse abdominis, internal and external obliques, psoas, multifidus, longissimus and gluteus maximus were measured bilaterally at consistent levels. Degenerative disc and bilateral facet joint disease were scored using established methods. Univariate analyses were performed using linear regression. Multivariate linear regression was performed to adjust for age, gender and BMI. CT density of each trunk muscle correlated inversely with age (p < 0.001) and BMI (p < 0.001). CT density of each trunk muscle correlated inversely with degenerative disc and facet joint disease in the univariate analyses (p < 0.001); however, only the gluteus maximus and the transverse abdominis remained significant predictors of degenerative disc and facet joint disease respectively in the multivariate analysis. Fatty infiltration of trunk musculature increases with age and BMI. Fatty infiltration of the gluteus maximus and transverse abdominis are associated with degenerative disc and facet joint disease, independent of age, gender and BMI. (orig.)

  13. Facet orientation and tropism: associations with spondylolysis.

    Science.gov (United States)

    Kalichman, Leonid; Guermazi, Ali; Li, Ling; Hunter, David J; Suri, Pradeep

    2010-04-01

    Cross-sectional study. To evaluate the association between lumbar spine facet joint orientation, facet joint tropism, and spondylolysis identified by multidetector computed tomography (CT) in the community-based Framingham Heart Study. The association between lumbar spondylolysis and facet orientation and tropism remains unclear. This study was an ancillary project to the Framingham Heart Study. Three thousand five hundred twenty-nine participants of the Framingham Heart Study aged 40 to 80 years underwent multidetector CT imaging to assess aortic calcification. One hundred ninety-one subjects were included in this ancillary study. Facet joint features and spondylolysis were evaluated on CT scans. The final analyzed sample included 104 men with mean age 51.90+/-11.25 years and 84 women with mean age 53.61+/-10.20 years. The association between spondylolysis and facet orientation and tropism was examined using univariate and multivariate analyses. Spondylolysis was prevalent in 11.5% of the total population. chi2 test demonstrated a significant sex difference in prevalence of spondylolysis (P=0.0154), with almost 3 times higher prevalence among men. There was no statistically significant difference in facet orientation and continuous facet tropism between individuals with and without spondylolysis at the L5 level (P=0.49 to 0.91). After adjustment for age, sex, and body mass index, no significant association between the occurrence of spondylolysis and facet orientation and tropism was found. In the studied sample the prevalence of facet joint osteoarthritis was significantly higher in individuals with spondylolysis than in those without spondylolysis at both sides of L4-L5 spinal level (P=0.044 at the right side and P=0.003 at the left side) and at left side of L5-S1 level (P=0.038). We did not find an association between facet orientation, facet tropism, and spondylolysis. One of the possible explanations for this is that the high prevalence of facet joint

  14. Treatment of lumbar facet joint syndrome by CT-guided intraarticular infiltration of fact joints; Behandlung des lumbalen Facettensyndroms durch CT-gesteuerte Infiltration der Zwischenwirbelgelenke

    Energy Technology Data Exchange (ETDEWEB)

    Schleifer, J. [Knappschaftsklinik Puettlingen/Saar (Germany). Orthopaedische Abteilung; Fenzl, G. [Knappschaftsklinik Puettlingen/Saar (Germany). Orthopaedische Abteilung; Wolf, A. [Knappschaftsklinik Puettlingen/Saar (Germany). Radiologische Abteilung; Diehl, K. [Knappschaftsklinik Puettlingen/Saar (Germany). Radiologische Abteilung

    1994-11-01

    In 62 patients with facet syndrome a total of 205 joints were infiltrated, CT monitoring being used in all cases. Each facet joint was infiltrated with 0.3 ml bupivacaine and 0.8 ml methylprednisolone. The patients were divided into three groups. Group 1 consisted of 24 persons who had undergone lumbar disc surgery, group 2 of 23 patients with spondylarthrosis of the facet joints, and group 3 of 15 patients who had undergone lumbar disc surgery but hat additional spondylarthrosis. Very good results were defined as pain relief for longer than 4 weeks, good results as pain relief for up to 4 weeks and poor results as brief pain relief or none at all. In 27 patients facet infiltration was performed for the purpose of diagnosis. Results were significantly in group 2 than in group 1. In group 3 results were better than in group 1, but worse than in group 2. These differences were not statistical by significant. Seven patients in the diagnostic group had no pain relief, and facet syndrome was excluded. (orig.) [Deutsch] Bei 62 Patienten mit lumbalem Facettensyndrom wurden insgesamt 205 Zwischenwirbelgelenke (Facettengelenke) perkutan CT-gesteuert infiltriert. Je Gelenk wurden 0,3 ml Bupivacain und 0,8 ml Methylprednisolon intraartikulaer infiziert. Die Patienten wurden in 3 Gruppen unterteilt. Die 1. Gruppe umfasste 24 Patienten mit Postnukleotomiesyndrom, die 2. Gruppe 23 Patienten mit spondylarthrotischen Veraenderungen, die 3. Gruppe 15 bandscheibenoperierte Patienten mit zusaetzlicher Spondylarthrose. In Gruppe 2 fanden sich signifikant bessere Ergebnisse als in Gruppe 1. Gute Resultate ergab auch die dritte Gruppe, sie waren jedoch nicht signifikant besser als die der Gruppe 1. Die sorgfaeltige Auswahl der Patienten ist fuer den Erfolg der Behandlung entscheidend. Die Infiltrationsbehandlung der Zwischenwirbelgelenke hat nahezu keine Nebenwirkungen. Ausser zur Therapie wird das Verfahren diagnostisch zum Ausschluss eines Facettensyndromes im Rahmen der Abklaerung

  15. Osseous associated cervical spondylomyelopathy at the C2-C3 articular facet joint in 11 dogs.

    Science.gov (United States)

    Cooper, C; Gutierrez-Quintana, R; Penderis, J; Gonçalves, R

    2015-11-21

    In dogs, vertebral canal stenosis at C2-C3 due to articular facet joint degeneration is only sporadically identified. The authors' aims were to review the clinical presentation, MRI characteristics, treatment and outcome of dogs presenting with this condition. Eleven cases were eligible for inclusion. Neurological examination revealed tetraparesis and proprioceptive ataxia in all 4 limbs in 3/11, proprioceptive tetra-ataxia only in 4/11, pelvic limb proprioceptive ataxia in 2/11 and no gait abnormalities in 2/11 dogs. Cervical hyperaesthesia was present in 7/11 dogs. MRI revealed bilateral articular facet joint degeneration in 10/11 cases and unilateral degeneration in one. Surgery was performed in six cases and medical management elected in five. Long-term follow-up information was available for 11 animals. Four of the surgical cases are alive and have no neurological deficits, one was euthanased for an unrelated condition and one lost to follow-up. Of the cases managed medically, three are alive showing no neurological deficits, one is alive still displaying neurological deficits and one euthanased for an unrelated condition whilst still ataxic. This study shows that both medical and surgical management can result in good outcomes in dogs with vertebral canal stenosis resulting from articular facet joint degeneration at the level of C2-C3. British Veterinary Association.

  16. Systematic review of patient history and physical examination to diagnose chronic low back pain originating from the facet joints.

    Science.gov (United States)

    Maas, E T; Juch, J N S; Ostelo, R W J G; Groeneweg, J G; Kallewaard, J W; Koes, B W; Verhagen, A P; Huygen, F J P M; van Tulder, M W

    2017-03-01

    Patient history and physical examination are frequently used procedures to diagnose chronic low back pain (CLBP) originating from the facet joints, although the diagnostic accuracy is controversial. The aim of this systematic review is to determine the diagnostic accuracy of patient history and/or physical examination to identify CLBP originating from the facet joints using diagnostic blocks as reference standard. We searched MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Collaboration database from inception until June 2016. Two review authors independently selected studies for inclusion, extracted data and assessed the risk of bias. We calculated sensitivity and specificity values, with 95% confidence intervals (95% CI). Twelve studies were included, in which 129 combinations of index tests and reference standards were presented. Most of these index tests have only been evaluated in single studies with a high risk of bias. Four studies evaluated the diagnostic accuracy of the Revel's criteria combination. Because of the clinical heterogeneity, results were not pooled. The published sensitivities ranged from 0.11 (95% CI 0.02-0.29) to 1.00 (95% CI 0.75-1.00), and the specificities ranged from 0.66 (95% CI 0.46-0.82) to 0.91 (95% CI 0.83-0.96). Due to clinical heterogeneity, the evidence for the diagnostic accuracy of patient history and/or physical examination to identify facet joint pain is inconclusive. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. © 2016 European Pain Federation - EFIC®.

  17. Management of low back pain with facet joint injections and nerve root blocks under computed tomography guidance. A prospective study

    International Nuclear Information System (INIS)

    Fotiadou, Anastasia; Wojcik, Andrew; Shaju, Antony

    2012-01-01

    The aim of this work was to assess the performance of facet joint and nerve root infiltrations under computed tomography guidance for the management of low back pain and to investigate the complications and patient tolerance. The study was board-certified and informed consent was obtained from all patients. In 1 year, 86 consecutive patients (47 male, 39 female, age range 47-87 years, mean age 63) with low back pain for more than 2 years were included. All patients were clinically examined and had cross-sectional imaging performed before the procedure. Fifty-five facet joint infiltrations and 31 nerve blocks were performed under computed tomography guidance. All patients completed two valid pain questionnaires before and 3 months after the procedures. At the same time, they were clinically examined by the referring Orthopaedic Surgeon. The pain response was assessed by comparing the scores of the questionnaires. The improvement in clinical examination findings was assessed as well. In patients who underwent facet joint infiltrations, long-term pain improvement was achieved in 79% and in those with nerve blocks in 85%. Immediate pain relief was demonstrated in 83% of patients with nerve infiltrations. No complications were observed. All procedures were very well tolerated by patients. Facet joint and nerve infiltrations under computed tomography guidance constitute an accurate and safe method that could be used to relieve low back pain and minimize the risk of disability. (orig.)

  18. Lumbar Facet Joint Compressive Injury Induces Lasting Changes in Local Structure, Nociceptive Scores, and Inflammatory Mediators in a Novel Rat Model

    Directory of Open Access Journals (Sweden)

    James L. Henry

    2012-01-01

    Full Text Available Objective. To develop a novel animal model of persisting lumbar facet joint pain. Methods. Sprague Dawley rats were anaesthetized and the right lumbar (L5/L6 facet joint was exposed and compressed to ~1 mm with modified clamps applied for three minutes; sham-operated and naïve animals were used as control groups. After five days, animals were tested for hind-paw sensitivity using von Frey filaments and axial deep tissue sensitivity by algometer on assigned days up to 28 days. Animals were sacrificed at selected times for histological and biochemical analysis. Results. Histological sections revealed site-specific loss of cartilage in model animals only. Tactile hypersensitivity was observed for the ipsi- and contralateral paws lasting 28 days. The threshold at which deep tissue pressure just elicited vocalization was obtained at three lumbar levels; sensitivity at L1>L3/4>L6. Biochemical analyses revealed increases in proinflammatory cytokines, especially TNF-α, IL-1α, and IL-1β. Conclusions. These data suggest that compression of a facet joint induces a novel model of local cartilage loss accompanied by increased sensitivity to mechanical stimuli and by increases in inflammatory mediators. This new model may be useful for studies on mechanisms and treatment of lumbar facet joint pain and osteoarthritis.

  19. The clinical aspects of the acute facet syndrome

    DEFF Research Database (Denmark)

    Hestbaek, Lise; Kongsted, Alice; Jensen, Tue Secher

    2009-01-01

    ABSTRACT: BACKGROUND: The term 'acute facet syndrome' is widely used and accepted amongst chiropractors, but poorly described in the literature, as most of the present literature relates to chronic facet joint pain. Therefore, research into the degree of consensus on the subject amongst a large g...... from the facet joints has been described in the literature. Furthermore, the acute, uncomplicated facet syndrome was considered to have an uncomplicated clinical course, responding quickly to spinal manipulative therapy....

  20. Evaluation of Facet Joint Arthrosis in Stenotic and Normal Lumbar Spines with MRI

    Directory of Open Access Journals (Sweden)

    Ebru Ozan

    2013-10-01

    Full Text Available Aim: To reveal the prevalence of lumbar facet joint arthrosis in normal and stenotic lumbar spines with magnetic resonance imaging. Material and Method: Study group consisted of 30 patients with complaints and findings of lower back pain, neurologic claudicatio and lumbar spinal stenosis detected at L3-4, L4-5 and/or L5-S1 with magnetic resonance imaging (cross section area of the dural sac

  1. FacetGist: Collective Extraction of Document Facets in Large Technical Corpora.

    Science.gov (United States)

    Siddiqui, Tarique; Ren, Xiang; Parameswaran, Aditya; Han, Jiawei

    2016-10-01

    Given the large volume of technical documents available, it is crucial to automatically organize and categorize these documents to be able to understand and extract value from them. Towards this end, we introduce a new research problem called Facet Extraction. Given a collection of technical documents, the goal of Facet Extraction is to automatically label each document with a set of concepts for the key facets ( e.g. , application, technique, evaluation metrics, and dataset) that people may be interested in. Facet Extraction has numerous applications, including document summarization, literature search, patent search and business intelligence. The major challenge in performing Facet Extraction arises from multiple sources: concept extraction, concept to facet matching, and facet disambiguation. To tackle these challenges, we develop FacetGist, a framework for facet extraction. Facet Extraction involves constructing a graph-based heterogeneous network to capture information available across multiple local sentence-level features, as well as global context features. We then formulate a joint optimization problem, and propose an efficient algorithm for graph-based label propagation to estimate the facet of each concept mention. Experimental results on technical corpora from two domains demonstrate that Facet Extraction can lead to an improvement of over 25% in both precision and recall over competing schemes.

  2. Long-term follow-up in sacroiliac joint pain patients treated with radiofrequency ablative therapy

    Directory of Open Access Journals (Sweden)

    Flávio Ramalho Romero

    2015-06-01

    Full Text Available Sacroiliac joint (SIJ pain is responsible for up to 40% of all cases of lumbar back pain. Objective Report the long-term efficacy of radiofrequency denervation for sacroiliac joint pain at six, twelve and eighteen months.Method Third-two adults’ patients with sacroiliac join pain diagnosis were included for a prospective study. Primary outcome measure was pain intensity on the Numeric Rating Scale (NRS. Secondary outcome measure was Patient Global Impression of Change Scale (PGIC.Results Short-term pain relief was observed, with the mean NRS pain score decreasing from 7.7 ± 1.8 at baseline to 2.8 ± 1.2 at one month and to 3.1 ± 1.9 at six months post-procedure (p < 0.001. Long-term pain relief was sustained at twelve and eighteen months post-procedure, with NRS pain remaining at 3.4 ± 2.1 and 4.0 ± 2.7, respectively.Conclusion Radiofrequency denervation of the SIJ can significantly reduce pain in selected patients with sacroiliac syndrome.

  3. Pulsed Radiofrequency Application for the Treatment of Pain Secondary to Sacroiliac Joint Metastases.

    Science.gov (United States)

    Yi, Yu Ri; Lee, Na Rea; Kwon, Young Suk; Jang, Ji Su; Lim, So Young

    2016-01-01

    Sacroiliac (SI) joint pain can result from degeneration, infection, malignancy, and trauma. Patients with metastatic bone pain who do not respond to conventional treatment may need more aggressive neuroinvasive approaches. Recently, pulsed radiofrequency (PRF) neuromodulation has emerged as a promising treatment alternative for refractory cases of SI joint pain. Nevertheless, there is no report on the treatment of pain arising from SI joint metastases with PRF. We are reporting about a 63-year-old woman suffering from buttock pain due to breast cancer metastases in the SI joint. We treated this patient with PRF neuromodulation of the L4-S3 primary dorsal rami and lateral branches using a rotating curved needle technique. The patient tolerated the procedures well, without any complications. She experienced about 70% reduction in pain, and pain relief was sustained for 10 months. This result suggests that PRF neuromodulation is a safe, effective treatment for pain from SI joint metastases.

  4. A critical evaluation of subtalar joint arthrosis associated with middle facet talocalcaneal coalition in 21 surgically managed patients: a retrospective computed tomography review. Investigations involving middle facet coalitions-part III.

    Science.gov (United States)

    Kernbach, Klaus J; Barkan, Howard; Blitz, Neal M

    2010-01-01

    Symptomatic middle facet talocalcaneal coalition is frequently associated with rearfoot arthrosis that is often managed surgically with rearfoot fusion. However, no objective method for classifying the extent of subtalar joint arthrosis exists. No study has clearly identified the extent of posterior facet arthrosis present in a large cohort treated surgically for talocalcaneal coalition through preoperative computerized axial tomography. The authors conducted a retrospective review of 21 patients (35 feet) with coalition who were surgically treated over a 12-year period for coalition on at least 1 foot. Using a predefined original staging system, the extent of the arthrosis was categorized into normal or mild (Stage I), moderate (Stage II), and severe (Stage III) arthrosis. The association of stage and age is statistically significant. All of the feet with Stage III arthrosis had fibrous coalitions. No foot with osseous coalition had Stage III arthrosis. The distribution of arthrosis staging differs between fibrous and osseous coalitions. Only fibrous coalitions had the most advanced arthrosis (Stage III), whereas osseous coalitions did not. This suggests that osseous coalitions may have a protective effect in the prevention of severe degeneration of the subtalar joint. Concomitant subtalar joint arthrosis severity progresses with age; surgeons may want to consider earlier surgical intervention to prevent arthrosis progression in patients with symptomatic middle facet talocalcaneal coalition.

  5. Value of 18F-FDG PET/MRI for the outcome of CT-guided facet block therapy in cervical facet syndrome: initial results

    International Nuclear Information System (INIS)

    Sawixki, Lino M.; Schaarscjmidt, Benedikt M.; Heusch, Philipp; Buchbender, Christian; Antoch, Gerald; Rosenbaum-Krumme, Sandra; Bockisch, Andreas; Umutlu, Lale; Eicker, Sven O.; Floeth, Frank W.

    2017-01-01

    The aim of this study was to evaluate the ability of 18 F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging ( 18 F-FDG PET/MRI) to detect PET-positive cervical facet arthropathy and identify patients who benefit from facet block therapy. Ten patients with cervical facet syndrome (mean age: 65 ± 12 years) underwent 18 F-FDG PET/MRI of the neck. Focal 18 F-FDG uptake in PET-positive facet joints served as target for computed tomography (CT)-guided facet blocks. In PET-negative patients, the target joint for facet block therapy was selected by current clinical standards considering the level of maximum facet arthrosis and pain. Neck pain was measured on visual analogue scale (VAS) before and after therapy. Bone marrow signal intensity (SI) ratio on turbo inversion recovery magnitude (TIRM) images and maximum standard uptake values (SUVmax) was calculated for each facet joint. Pearson's correlation coefficient (r) was calculated between bone marrow SI ratios on TIRM and SUVmax. 18 F-FDG PET/MRI detected PET-positive facet arthropathy in six patients. Patients with PET-positive facet arthropathy had significantly less pain compared with the pretreatment pain 3 h (P = 0.002), 4 weeks (P = 0.002) and 3 months (P = 0.026) after facet block therapy. Pain did not change significantly in patients with PET-negative facet arthropathy. TIRM SI ratio was higher in PET-positive facet arthropathy than in PET-negative facet arthropathy (P < 0.001). Correlation was strong between bone marrow SI ratio on TIRM images and SUVmax (r = 0.7; P < 0.001).

  6. Cervical Facet Joint Infection and Associated Epidural Abscess with Streptococcus intermedius from a Dental Infection Origin A Case Report and Review.

    Science.gov (United States)

    Kaye, Ian David; Protopsaltis, Themistocles S

    2016-09-01

    Pyogenic cervical facet joint infections are rare and such infections from a dental origin are even less common. Of these few cases, none have described infection with Streptococcus intermedius as the pathogen. A 65-year-old orthopaedic surgeon complained of fevers, right-sided radiating neck pain, stiffness, swelling, erythema, and right upper extremity weakness one month after he had broken a crown over his right mandibular premolar, a continued source of pain. Imaging of the cervical spine showed a right C4-C5 facet inflammatory arthropathy and a small epidural abscess that was cultured and initially treated with intravenous antibiotics. The oral maxillofacial surgery team performed an extraction of the infected, symptomatic tooth. For continued right upper extremity weakness, the patient underwent C4-C5 laminoforaminotomy and irrigation and debridement of the right C4-C5 facet joint. After 6 weeks of intravenous antibiotics, the patient's infectious and inflammatory markers had normalized. By 4 months, he had regained full strength at his upper extremity and a painless and full range of motion of his cervical spine.Pyogenic cervical facet joint infection is very rare and potentially dangerous. A high clinical suspicion and appropriate imaging, including magnetic resonance imaging, are important for correct diagnosis. Prompt medical and surgical treatment may avert complications, and although the patient presented made a complete recovery, patients may be left with neurological compromise.

  7. Septic arthritis of a lumbar facet joint: Detection with bone SPECT imaging

    International Nuclear Information System (INIS)

    Swayne, L.C.; Dorsky, S.; Caruana, V.; Kaplan, I.L.

    1989-01-01

    We present a rare case of septic arthritis of a lumbar facet joint with an associated epidural abscess resulting from Staphylococcus aureus. The infection was initially detected with planar bone scintigraphy and precisely localized with single photon emission computed tomography bone scintigraphy, despite an initially negative radiologic evaluation that included radiographs of the lumbar spine, lumbar myelography, and a postmyelography x-ray computed tomography scan. In the appropriate clinical setting, a bone scan demonstrating unilateral increased activity within the spine should raise the suspicion of inflammatory involvement of the posterior elements

  8. Pseudomeningocele in communication with the facet joint: demonstration by computerized tomography-arthrography

    International Nuclear Information System (INIS)

    Ganiyusufoglu, Kursat; Ozturk, Cagatay; Sirvanci, Mustafa; Aksu, Neslihan; Hamzaoglu, Azmi

    2008-01-01

    Pseudomeningocele is an uncommon but well-known complication of lumbar spine operations. Although it is mostly asymptomatic and managed conservatively in most cases, it is claimed as a causative factor of failed back surgery syndrome and requires surgery in some cases. Usually, its diagnosis is confidently done with imaging modalities such as magnetic resonance imaging, computed tomography and myelography. In this report, we describe a case of pseudomeningocele that communicated with a facet joint. The diagnostic approach for this unusual lesion and its probable causes are discussed. (orig.)

  9. Pseudomeningocele in communication with the facet joint: demonstration by computerized tomography-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Ganiyusufoglu, Kursat; Ozturk, Cagatay; Sirvanci, Mustafa; Aksu, Neslihan; Hamzaoglu, Azmi [Florence Nightingale Hospital, Istanbul Bilim University, Istanbul Spine Center, Istanbul (Turkey)

    2008-08-15

    Pseudomeningocele is an uncommon but well-known complication of lumbar spine operations. Although it is mostly asymptomatic and managed conservatively in most cases, it is claimed as a causative factor of failed back surgery syndrome and requires surgery in some cases. Usually, its diagnosis is confidently done with imaging modalities such as magnetic resonance imaging, computed tomography and myelography. In this report, we describe a case of pseudomeningocele that communicated with a facet joint. The diagnostic approach for this unusual lesion and its probable causes are discussed. (orig.)

  10. Bending stresses in Facetted Glass Shells

    DEFF Research Database (Denmark)

    Bagger, Anne; Jönsson, Jeppe; Almegaard, Henrik

    2008-01-01

    A shell structure of glass combines a highly effective structural principle with a material of optimal permeability to light. A facetted shell structure has a piecewise plane geometry, and together the facets form an approximation to a curved surface. A distributed load on a plane-based facetted...... structure will locally cause bending moments in the loaded facets. The bending stresses are dependent on the stiffness of the joints. Approximate solutions are developed to estimate the magnitude of the bending stresses. A FE-model of a facetted glass shell structure is used to validate the expressions...

  11. The Treatment of Joint Pain with Intra-articular Pulsed Radiofrequency.

    Science.gov (United States)

    Schianchi, Pietro M; Sluijter, Menno E; Balogh, Susan E

    2013-09-01

    The intra-articular (IA) application of pulsed radiofrequency (PRF) for pain in small and large joints represents a recent development that has proven to be effective in many cases. We performed a retrospective study of 89 such procedures in 57 consecutive patients with chronic articular pain. The aim of this retrospective study is to evaluate the effectiveness of intraarticular PRF in a group of 57 consecutive patients with chronic joint pain. Patients with intractable joint pain for more than 6 months were treated with IA PRF 40-45V for 10-15 min in small joints and 60V for 15 min in large joints using fluoroscopic confirmation of correct needle position. A total of 28 shoulders, 40 knees, 10 trapezio-metacarpal, and 11 first metatarso-phalangeal joints were treated. Results were evaluated at 1, 2, and 5 months. The procedure was repeated after 1 month in 10 patients with initial suboptimal results. Success was defined as a reduction of pain score by at least 50%. All groups showed significant reductions in pain scores at all three follow-up visits. Success rates were higher in small joints (90% and 82%, respectively) than large ones (64% and 60%, respectively). Interestingly, IA PRF was successful in 6 out of 10 patients who had undergone previous surgery, including 3 with prosthetic joint replacement and in 6 of the 10 repeated procedures. There were no significant adverse effects or complications. IA PRF induced significant pain relief of long duration in a majority of our patients with joint pain. The exact mechanism is unclear, but may be related to the exposure of immune cells to low-strength RF fields, inducing an anti-inflammatory effect. The success rate appears to be highest in small joints. We recommend additional research including control groups to further investigate and clarify this method; our data suggest that it may represent a useful modality in the treatment of arthrogenic pain.

  12. Biomechanical analysis of press-extension technique on degenerative lumbar with disc herniation and staggered facet joint

    Directory of Open Access Journals (Sweden)

    Hong-gen Du

    2016-05-01

    Full Text Available This study investigates the effect of a new Chinese massage technique named “press-extension” on degenerative lumbar with disc herniation and facet joint dislocation, and provides a biomechanical explanation of this massage technique. Self-developed biomechanical software was used to establish a normal L1–S1 lumbar 3D FE model, which integrated the spine CT and MRI data-based anatomical structure. Then graphic technique is utilized to build a degenerative lumbar FE model with disc herniation and facet joint dislocation. According to the actual press-extension experiments, mechanic parameters are collected to set boundary condition for FE analysis. The result demonstrated that press-extension techniques bring the annuli fibrosi obvious induction effect, making the central nucleus pulposus forward close, increasing the pressure in front part. Study concludes that finite element modelling for lumbar spine is suitable for the analysis of press-extension technique impact on lumbar intervertebral disc biomechanics, to provide the basis for the disease mechanism of intervertebral disc herniation using press-extension technique.

  13. Lumbar facet joint septic arthritis presenting atypically as acute abdomen – A case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Aysha Rajeev

    2016-01-01

    Conclusion: The atypical presentation of facet joint septic arthritis is one of the reasons why early diagnosis is elusive. Definitive diagnoses with MRI and bacterial culture as well as prolonged antibiotic therapy are recommended in this condition.

  14. MRI-guided focused ultrasound (MRgFUS) to treat facet joint osteoarthritis low back pain - case series of an innovative new technique

    Energy Technology Data Exchange (ETDEWEB)

    Weeks, Evan M.; Platt, Michael W. [St Mary' s Hospital, Imperial College Healthcare NHS Trust, Department of Anaesthesia and Pain Medicine, London (United Kingdom); Gedroyc, Wladyslaw [St Mary' s Hospital, Imperial College Healthcare NHS Trust, Department of Radiology, London (United Kingdom)

    2012-12-15

    To evaluate the safety and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) to treat facet joint osteoarthritis pain. Patients with a positive response to facet joint interventions were recruited from Pain and Spinal Clinics. Treatments were performed at the levels of pain according to symptomatology, previous invasive treatment and MRI grading of facet joint osteoarthritis. Both safety and efficacy data were collected. Pain palliation was evaluated using a validated pain numerical rating scale (NRS), Oswestry disability questionnaire (ODQ), Brief Pain Inventory (BPI) and the EuroQol (EQ-5D) health state score Eighteen patients were treated. There were no major adverse events. At 6/12 we found a reduction in both the NRS (average/worst) pain scores (60.2 %/51.2 %). This was associated with 45.9 % improvement in the ODQ score and 61.9 % reduction in the BPI interference score. We observed an improvement in the EuroQol (EQ-5D) health state score based on UK coefficients of +0.379 (0.317 to 0.696). Our phase I observational pilot study has evaluated an innovative new technique that is both non-invasive and radiation free. It is the first description of this procedure in the literature. In all patients the technique was safe, free of complications, effective and well tolerated. (orig.)

  15. MRI-guided focused ultrasound (MRgFUS) to treat facet joint osteoarthritis low back pain - case series of an innovative new technique

    International Nuclear Information System (INIS)

    Weeks, Evan M.; Platt, Michael W.; Gedroyc, Wladyslaw

    2012-01-01

    To evaluate the safety and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) to treat facet joint osteoarthritis pain. Patients with a positive response to facet joint interventions were recruited from Pain and Spinal Clinics. Treatments were performed at the levels of pain according to symptomatology, previous invasive treatment and MRI grading of facet joint osteoarthritis. Both safety and efficacy data were collected. Pain palliation was evaluated using a validated pain numerical rating scale (NRS), Oswestry disability questionnaire (ODQ), Brief Pain Inventory (BPI) and the EuroQol (EQ-5D) health state score Eighteen patients were treated. There were no major adverse events. At 6/12 we found a reduction in both the NRS (average/worst) pain scores (60.2 %/51.2 %). This was associated with 45.9 % improvement in the ODQ score and 61.9 % reduction in the BPI interference score. We observed an improvement in the EuroQol (EQ-5D) health state score based on UK coefficients of +0.379 (0.317 to 0.696). Our phase I observational pilot study has evaluated an innovative new technique that is both non-invasive and radiation free. It is the first description of this procedure in the literature. In all patients the technique was safe, free of complications, effective and well tolerated. (orig.)

  16. Unusual case of paediatric septic arthritis of the lumbar facet joints due to Kingella kingae.

    Science.gov (United States)

    Le Hanneur, M; Vidal, C; Mallet, C; Mazda, K; Ilharreborde, B

    2016-11-01

    A 32-month-old boy presented with febrile limping that had developed over 6days, associated with right lumbosacral inflammatory swelling. Magnetic resonance imaging (MRI) showed joint effusion of the right L5-S1 zygapophyseal joint, complicated by destructive osteomyelitis of the L5 articular process and paraspinal abscess. Surgery was decided to evacuate the fluid accumulation and rule out differential diagnoses. The diagnosis of septic arthritis of the facet joint was confirmed intraoperatively; real-time quantitative PCR analysis identified Kingella kingae. This is the first substantiated paediatric case of zygapophyseal joint septic arthritis due to K. kingae. K. kingae is the most common pathogen responsible for invasive osteoarticular infection in children under 4years of age. Since empiric antibiotics are effective in early stages, physicians should consider the possibility of spinal infections due to K. kingae when a limping child under 4years of age presents with a fever. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Isolated septic facet joint arthritis as a rare cause of acute and chronic low back pain – a case report and literature review

    International Nuclear Information System (INIS)

    Klekot, Dominika; Zimny, Anna; Czapiga, Bogdan; Sąsiadek, Marek

    2012-01-01

    The most common cause of low back pain is degenerative disease of the intervertebral disc and other structures of the lumbar spine. However, in some cases other less frequent causes of such pain can be seen, for example septic facet joint arthritis. Until now, only 40 cases of such inflammatory changes within the spine have been reported in the literature. The disease is probably underestimated due to improper diagnostic pathway. The authors describe a case of a 53-year-old woman who was repeatedly hospitalized during a five-month period because of an acute, severe low back pain, with sphincter dysfunction, partially resembling sciatic symptoms. Physical examinations revealed also focal tenderness in the area of the lumbar spine. Inflammatory markers (ESR – erythrocyte sedimentation rate, CRP – C-reactive protein) were elevated. Conservative analgetic treatment brought only partial and temporary relief of the pain and symptoms. The final accurate diagnosis of isolated septic facet joint arthritis at the level of L5/S1 was established after several months from the onset of the first symptoms, after performing various imaging examinations, including bone scintigraphy as well as CT and MRI of the lumbosacral spine. The patient fully recovered after antibiotic therapy and surgery, which was proven in several follow-up examinations showing no relevant pathology of the lumbar spine. The authors broadly describe the etiology and clinical symptoms of the septic facet joint arthritis as well as the significant role of imaging methods, especially MRI, in diagnostic process. The authors also discuss currently available treatment options, both conservative and surgical. The diagnostic procedure of septic facet joint arthritis requires several steps to be taken. Establishing a correct diagnosis may be difficult, that is why it is important to remember about rare causes of low back pain and to perform detailed physical examination, laboratory tests and choose appropriate

  18. Short-term outcome of fluoroscopic-guided steroid injection therapy of lumber facet cyst-induced radicular pain

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Mi Ri; Kwon, Jong Won; Lee, Jong Seo; Kim, Eu Sang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    To determine the short-term effect of fluoroscopic-guided steroid injection therapy of lumbar facet cyst-induced radicular pain. Seventeen patients with radiculopathy due to lumbar synovial cysts, who were treated with fluoroscopically guided injection, were retrospectively evaluated. All plain radiographic images and MR images before the therapy were reviewed. Five patients underwent only the facet joint injection, whereas twelve patients underwent the facet joint injection with perineural injection therapy. The clinical course of pain was evaluated on the first follow-up after therapy. Effective pain relief was achieved in 11 (64.7%) of the 17 patients. Among 12 patients who underwent facet joint injection with perineural injection, 9 patients (75%) had an effective pain relief. Of 5 patients, 2 (40%) patients only took the facet joint injection and had an effective pain relief. Fluoroscopic-guided steroid injection therapy shows a good short-term effect in patients with symptomatic lumbar facet joint synovial cysts.

  19. Lumbar Facet Joint Arthritis Is Associated with More Coronal Orientation of the Facet Joints at the Upper Lumbar Spine

    International Nuclear Information System (INIS)

    Jentzsch, Th.; Geiger, J.; Zimmermann, S.M.; Slankamenac, K.; Werner, C.M.L.; Nguyen-Kim, Th.D.L.

    2013-01-01

    We retrospectively analyzed CT scans of 620 individuals, who presented to our traumatology department between 2008 and 2010. Facet joint (FJ) arthritis was present in 308 (49.7%) individuals with a mean grade of 1. It was seen in 27% of individuals ≤40 years and in 75% of individuals ≥41 years ( Ρ <0.0001) as well as in 52% of females and 49% of males ( Ρ=0.61). Mean FJ orientation was 30.4° at L2/3, 38.7° at L3/4, 47° at L4/5, and 47.3° at L5/S1. FJ arthritis was significantly associated with more coronal (increased degree) FJ orientation at L2/3 (Ρ=0.03) with a cutoff point at ≥32°. FJs were more coronally oriented (48.8°) in individuals ≤40 years and more sagittally oriented (45.6°) in individuals ≥41 years at L5/S1 (Ρ=0.01). Mean FJ asymmetry was 4.89° at L2/3, 6.01° at L3/4, 6.67° at L4/5, and 7.27° at L5/S1, without a significant difference for FJ arthritis. FJ arthritis is common, increases with age, and affects both genders equally. More coronally oriented FJs (≥32°) in the upper lumbar spine may be an individual risk factor for development of FJ arthritis.

  20. The lumbar facet arthrosis syndrome. Clinical presentation and articular surface changes.

    Science.gov (United States)

    Eisenstein, S M; Parry, C R

    1987-01-01

    We describe a lumbar facet syndrome in which disabling symptoms are associated with normal or near-normal plain radiographs. Local spinal fusion relieved symptoms in 12 patients; the excised facet joint surfaces showed some of the histological changes seen in chondromalacia patellae and in osteoarthritis of other large joints. The most frequent change was focal full-thickness cartilage necrosis or loss of cartilage with exposure of subchondral bone, but osteophyte formation was remarkably absent in all specimens. We suggest that there are both clinical and histological similarities between the facet arthrosis syndrome and chondromalacia patellae. Facet arthrosis may be a relatively important cause of intractable back pain in young and middle-aged adults.

  1. THERAPEUTIC EFFECTIVENESS OF THORACIC FACET JOINT INTERVENTIONS IN CHRONIC THORACIC PAIN%X光引导胸椎小关节注射治疗胸背痛的疗效观察

    Institute of Scientific and Technical Information of China (English)

    李晓宏; 李世杰; 黄翔; 富沛勇; 杨承祥

    2013-01-01

    目的:评价小关节注射治疗胸背部疼痛的临床疗效及安全性.方法:60例经保守治疗无效的慢性胸背痛患者,随机分为超激光治疗组(S组,n=30)和介入治疗组(Ⅰ组,n=30).S组患者取俯卧位,超激光照射病变关节部位,每天1次,每次15 rain,共14次;Ⅰ组患者取俯卧位,在X光引导下确定病变小关节平面,穿刺针经皮正确无误到达胸椎后关节突关节间隙,到位后注射消炎镇痛液.对治疗后第1周、2周、1个月、3个月的VAS进行评分、生活质量改善情况及安全性进行评估.结果:与S组比较,Ⅰ组治疗患者术后3个月的VAS评分较治疗前有显著性降低(P<0.05),且未发现有严重并发症.结论:小关节注射治疗胸背痛是一项操作简便、安全,疗效确切、可靠的微创介入治疗方法.%Objective:To determine the clinical effectiveness of zygapophysial joint injections with fluoroscopy in managing chronic mid back or upper back pain of facet joint origin.Methods:A total of 60 patients were randomized divided into two groups,with 30 patients in each of the super laser and facet joint interventions groups.All of the patients met the diagnostic criteria of thoracic facet joint pain by means of the inclusion criteria.Group S patients received thoracic facet joint with super laser,whereas Group Ⅰ patients received thoracic facet joint intervention with bupivacaine and non-particulate betamethasone.The clinical efficacy were assessed by patients with visual analogue scale(VAS).All outcomes were assessed at baseline,1 week,2 weeks,1 month,and 3 months after treatment.Results:In Group S,compared with baseline,patients showed significant pain relief and functional improvement at 1 week (P < 0.05) But there were no significant pain relief after 2 weeks.In Group Ⅰ,patients showed significant pain relief and functional improvement after facet joint injection,a significant change 3 months after treatment from baseline (P < 0

  2. Arthroscopic surgery using radio-frequency electrocautery

    International Nuclear Information System (INIS)

    Takatsuka, Shigeyuki; Yoshida, Kan; Nakagawa, Kiyomasa; Yamamoto, Etsuhide; Kubota, Yoshiyuki; Narinobou, Masayoshi; Terai, Koichi; Hasegawa, Hiroshi

    2008-01-01

    Arthroscopic surgery using radio-frequency electrocautery was carried out on 23 temporomandibular joints (TMJs) in 13 patients. Because these patients did not respond to conservative therapy, surgery was indicated. Preoperative MRI showed anterior disc displacement without reduction in all patients. Disturbed translation was also recognized in all of the discs and mandibular condyles. Intraoperative arthroscopic examination showed severe fibrous adhesion in the upper joint compartment and disc displacement. Four joints showed perforation between the disc and retrodiscal tissue. Postoperative findings included an increased range of vertical maximal mouth opening and decreased pain on mandibular movement. Analyses of postoperative MRI indicated recovery of disc and condylar translation. These results suggested that the introduction of arthroscopic surgery using radiofrequency electrocautery would significantly reduce the number of patients with osteoarthritic TMJ disorders. (author)

  3. Gradient-echo imaging of intervertebral disk degeneration and facet joint disease

    International Nuclear Information System (INIS)

    Berns, D.H.; Kormos, D.; Modic, M.T.; Carter, J.; Masaryk, T.J.; Ross, J.S.

    1988-01-01

    The purpose of this study was to evaluate the accuracy of gradient-echo, partial-flip angle images in the evaluation of components of degenerative spine disease. First, cadaveric spines were studied with plain radiographs, high-resolution CT, T1-weighted spin-echo (SE) MR images (repetition time msec/echo time msec=500/17). T2-weighted SE images (2,000/30-90), and fast low-angle shot (FLASH) images (200/10.50 0 ) before and after intradiskal injection of air (0.1-1cc). Second, lumbar spine MR images were retrospectively evaluated to compare gradient-echo and SE sequences. Results indicate that the signal intensity changes of the intervertebral disk related to degeneration were best appreciated on T2-weighted SE studies in both groups. Vacuum phenomenon and calcification were most accurately assessed with FLASH imaging (based on susceptibility changes) and CT images. SE images appeared more sensitive to adjacent marrow change. In the facet joints, CT was more accurate for changes in the subarticular bone, but FLASH images were more sensitive to change in the articular cartilage

  4. Investigation of stresses in facetted glass shell structures

    DEFF Research Database (Denmark)

    Bagger, Anne; Jönsson, Jeppe; Wester, Ture

    2007-01-01

    by in-plane forces in the facets and the transfer of distributed in-plane forces across the joints. It is described how these facets work structurally, specifically how bending moments develop and cause possible stress concentrations in the corners, which are subjected to uplift. Apart from local...... bending moments from distributed load, other types of bending moments are likely to occur, especially if the shell has areas of low stiffness, for example along a free edge. A facetted shell structure has been modelled in a finite element program, and the resulting stresses are presented and discussed....

  5. Pain from intra-articular NGF or joint injury in the rat requires contributions from peptidergic joint afferents.

    Science.gov (United States)

    Kras, Jeffrey V; Weisshaar, Christine L; Pall, Parul S; Winkelstein, Beth A

    2015-09-14

    Non-physiological stretch of the cervical facet joint's capsular ligament induces persistent behavioral hypersensitivity and spinal neuronal hyperexcitability via an intra-articular NGF-dependent mechanism. Although that ligament is innervated by nociceptors, it is unknown if a subpopulation is exclusively responsible for the behavioral and spinal neuronal responses to intra-articular NGF and/or facet joint injury. This study ablated joint afferents using the neurotoxin saporin targeted to neurons involved in either peptidergic ([Sar(9),Met (O2)(11)]-substance P-saporin (SSP-Sap)) or non-peptidergic (isolectin B4-saporin (IB4-Sap)) signaling to investigate the contributions of those neuronal populations to facet-mediated pain. SSP-Sap, but not IB4-Sap, injected into the bilateral C6/C7 facet joints 14 days prior to an intra- articular NGF injection prevents NGF-induced mechanical and thermal hypersensitivity in the forepaws. Similarly, only SSP- Sap prevents the increase in mechanical forepaw stimulation- induced firing of spinal neurons after intra-articular NGF. In addition, intra-articular SSP-Sap prevents both behavioral hypersensitivity and upregulation of NGF in the dorsal root ganglion after a facet joint distraction that normally induces pain. These findings collectively suggest that disruption of peptidergic signaling within the joint may be a potential treatment for facet pain, as well as other painful joint conditions associated with elevated NGF, such as osteoarthritis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Comparison of QuadrapolarTM radiofrequency lesions produced by standard versus modified technique: an experimental model

    Directory of Open Access Journals (Sweden)

    Safakish R

    2017-06-01

    Full Text Available Ramin Safakish Allevio Pain Management Clinic, Toronto, ON, Canada Abstract: Lower back pain (LBP is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI joint pain is responsible for LBP in 18%–30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques. Keywords: lower back pain, radiofrequency ablation, sacroiliac joint, Quadrapolar radiofrequency ablation

  7. Intraarticular Facet Injections for Low Back Pain: Design Considerations, Consensus Methodology to Develop the Protocol for a Randomized Controlled Trial.

    Science.gov (United States)

    Mars, Tom; Ellard, David R; Antrobus, James H L; Cairns, Melinda; Underwood, Martin; Haywood, Kirstie; Keohane, Susie; Sandhu, Harbinder; Griffiths, Frances

    2015-01-01

    Since the publication of guidelines by the UK National Institute for Health and Care Excellence (NICE) and the American Pain Society guidelines for low back pain in 2009 there have been deep divisions in the pain treatment community about the use of therapeutic intraarticular facet joint injections. While evidence for the effectiveness or not of intraarticular facet joint injections remains sparse, uncertainty will remain. The Warwick feasibility study, along with a concurrent study with a different design led by another group, aims to provide a stable platform from which the effectiveness and cost effectiveness of intraarticular facet joint injections added to normal care could be evaluated in randomized controlled trials (RCTs). To reach consensus on key design considerations for the Warwick facet feasibility study from which the study protocol and working manuals will be developed. A consensus conference involving expert professionals and lay members. Preliminary work identified 5 key design considerations for deliberation at our consensus conference. Three concerned patient assessment and treatment: diagnosis of possible facet joint pain, interaarticular facet joint injection technique, and best usual care. Two concerned trial analysis: a priori sub-groups and minimally important difference and are reported elsewhere. We did systematic evidence reviews of the design considerations and summarized the evidence. Our design questions and evidence summaries were distributed to all delegates. This formed the basis for discussions on the day. Clinical experts in all aspects of facet joint injection from across the UK along with lay people were invited via relevant organizations. Nominal group technique was used in 15 facilitated initial small group discussions. Further discussion and ranking was undertaken in plenary. All small group and plenary results were recorded and checked and verified post conference. Where necessary participants were contacted via email to

  8. Characteristic MRI and MR Myelography Findings for the Facet Cyst Hematoma at T12-L1 Spine: A Case Report

    International Nuclear Information System (INIS)

    Chung, Seung Eun; Lee, Sang Ho; Kim, Tae Hong; Choi, Gun; Paeng, Sung Suk

    2011-01-01

    A facet cyst is a very rare condition in the thoracolumbar spine and more so, hemorrhage into a cyst is extremely rare. We present a case of a facet cyst hematoma in the T12-L1 spine. A 69-year-old woman complained of chronic back pain with right lower extremity pain, and weakness for 3 years. MRI and MR myelography showed an extradural mass at the T12-L1 level with heterogeneous signal intensity on both T1-and T2-weighted images, which was continuous to the right T12-L1 facet joint. The neighboring facet joint showed severe degeneration on the CT scan. The mass a was simple hematoma covered with a thin fibrous membrane and connected with facet joint macroscopically and microscopically. The pathogenesis of the facet cyst hematoma is not clear but it can compress nerve roots or dura mater and cause radiculopathy or cauda equina syndrome. Surgical removal should be recommended for symptomatic relief.

  9. Characteristic MRI and MR Myelography Findings for the Facet Cyst Hematoma at T12-L1 Spine: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Seung Eun [Dept of Diagnostic Radiology, Wooridul Spine Hospital, Seoul (Korea, Republic of); Lee, Sang Ho [Dept. of Neurosurgery, Wooridul Spine Hospital, Seoul (Korea, Republic of); Kim, Tae Hong [Dept. of Neurosurgery, Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of); Choi, Gun [Dept. of Neurosurgery, Seoul Wooridul Hospital, Seoul (Korea, Republic of); Paeng, Sung Suk [Dept of Radiology, Wooridul Spine Hospital, Seoul (Korea, Republic of)

    2011-05-15

    A facet cyst is a very rare condition in the thoracolumbar spine and more so, hemorrhage into a cyst is extremely rare. We present a case of a facet cyst hematoma in the T12-L1 spine. A 69-year-old woman complained of chronic back pain with right lower extremity pain, and weakness for 3 years. MRI and MR myelography showed an extradural mass at the T12-L1 level with heterogeneous signal intensity on both T1-and T2-weighted images, which was continuous to the right T12-L1 facet joint. The neighboring facet joint showed severe degeneration on the CT scan. The mass a was simple hematoma covered with a thin fibrous membrane and connected with facet joint macroscopically and microscopically. The pathogenesis of the facet cyst hematoma is not clear but it can compress nerve roots or dura mater and cause radiculopathy or cauda equina syndrome. Surgical removal should be recommended for symptomatic relief.

  10. A report of 3 soldiers returned to full duty after lumbar radiofrequency facet denervation in a theater of war.

    Science.gov (United States)

    Dragovich, Anthony; Trainer, Robert J

    2011-04-01

    To provide the advanced interventional procedure of zygapophysial joint neurotomy to soldiers meeting the diagnostic criteria in a combat environment and thus reduce medical evacuations of soldiers from a theater of war. Retrospective chart review was performed on three consecutive soldiers who received neuroablation of the lumbar ZP joint. Patients received single MBB with 1 cc of 1% lidocaine at the b/l L3-L5 levels considered diagnostic if >50% analgesia was achieved concordant with duration of anesthetic.   All procedures were co-performed by the two authors at the Ibn Sina hospital in Baghdad, Iraq over a 3-month period. Three consecutive patients with >50% pain relief from diagnostic medial branch blocks were treated with radiofrequency ablation of the bilateral L3-L4 medial branch nerves and L5 posterior primary ramus. Sensory test stimulation at 50 Hz and motor stimulation at 2 Hz were performed at each level. The nerves were then lesioned at 80° Centigrade for 90 seconds after injection of lidocaine and methylprednisolone. Procedure was considered successful if patients were able to wear body armour without significant discomfort (at least 1 hour/day). Medical evacuation from Iraq was prevented and all soldiers returned to rigorous combat duties including the wearing of body armour daily. We believe to be the first to report on the use of RF nerve ablation in a war time setting and with this functional outcome. Wiley Periodicals, Inc.

  11. Differences Regarding Branded HA in Italy, Part 2: Data from Clinical Studies on Knee, Hip, Shoulder, Ankle, Temporomandibular Joint, Vertebral Facets, and Carpometacarpal Joint

    Science.gov (United States)

    Migliore, A.; Bizzi, E.; De Lucia, O.; Delle Sedie, A.; Tropea, S.; Bentivegna, M.; Mahmoud, A.; Foti, C.

    2016-01-01

    OBJECTIVES The aim of the current study is to collect scientific data on all branded hyaluronic acid (HA) products in Italy that are in use for intra-articular (IA) injection in osteoarthritis (OA) compared with that reported in the leaflet. METHODS An extensive literature research was performed for all articles reporting data on the IA use of HA in OA. Selected studies were taken into consideration only if they are related to products based on HAs that are currently marketed in Italy with the specific joint indication for IA use in patients affected by OA. RESULTS Sixty-two HA products are marketed in Italy: 30 products are indicated for the knee but only 8 were proved with some efficacy; 9 products were effective for the hip but only 6 had hip indication; 7 products proved to be effective for the shoulder but only 3 had the indication; 5 products proved effective for the ankle but only one had the indication; 6 products were effective for the temporomandibular joint but only 2 had the indication; only 2 proved effective for vertebral facet joints but only 1 had the indication; and 5 products proved effective for the carpometacarpal joint but only 2 had the indication. CONCLUSIONS There are only a few products with some evidences, while the majority of products remain without proof. Clinicians and regulators should request postmarketing studies from pharmaceuticals to corroborate with that reported in the leaflet and to gather more data, allowing the clinicians to choose the adequate product for the patient. PMID:27279754

  12. Facet orientation and tropism: Associations with asymmetric lumbar paraspinal and psoas muscle parameters in patients with chronic low back pain.

    Science.gov (United States)

    Xu, W B; Chen, S; Fan, S W; Zhao, F D; Yu, X J; Hu, Z J

    2016-08-10

    Many studies have explored the relationship between facet tropism and facet joint osteoarthritis, disc degeneration and degenerative spondylolisthesis. However, the associations between facet orientation and tropism, and paraspinal muscles have not been studied. To analyze the associations between facet orientation and tropism, and parameters of paraspinal muscles in patients with chronic low back pain. Ninety-five patients with chronic low back pain were consecutively enrolled. Their facet joint angles were measured on computed tomography (CT) while gross cross-sectional area (GCSA), functional cross-sectional area (FCSA) and T2 signal intensity of lumbar paraspinal and psoas muscle were evaluated on magnetic resonance imaging (MRI). The GCSA and FCSA were significantly smaller for multifidus muscle (Plow back pain. Longitudinal studies are needed to understand the causal relationship between facet orientation and tropism and muscular asymmetry in future.

  13. Superior facet syndrome

    International Nuclear Information System (INIS)

    Kubo, Yoshichika; Igarashi, Seishi; Koyama, Tsunemaro

    1985-01-01

    Sciatica caused by root entrapment in the lateral recess was named superior facet syndrome by Epstein in 1972. Few reports on this subject based on large numbers of cases have been documented to date. Of the patients with sciatica, 32 patients were diagnosed to have root entrapment at the lateral recess L 5 or/and S 1 lumbar spine. Out of 32 patients, 20 patients were operated on and the lateral entrapment was recognized in all of surgical cases. Neuroradiological findings, especially of metrizamide CT (met. CT), were documented in detail. Thirty two patients were classified in three types according to radiological findings. They were congenital or developmental, degenerative, and combined type, respectively, Fourteen cases belonged to the congenital type, 13 to the degenerative and 5 to the combined type. Each group had the mean ages of 23.4, 53.8, and 36.8 years old, respectively. Of 32 cases the entrapment occured in 47 L 5 roots and 11 S 1 roots. There was no remarkable laterality. In operation the unroofing of the lateral recess were done and the sciatica subsided postoperatively in all of surgical cases. Met. CT revealed extreme medial protrusion of the superior articular joint in 18 of 24 cases(75%) and none filling of the root in the lateral recess in 21 of 24 cases (87.5%). In the degenerative type, met. CT showed some degenerative changes that were hypertrophy or deformity of the articular joints and spur formation of the vertebral body. In contrast to met. CT, metrizamide myelography revealed only slight changes, which were poor filling of the root before it turned out the pedicle of lateral compression of the root. In plain films or lumbar spine articular joints at Lsub(4/5) were formed in coronal plane in 69% of cases of the L 5 root entrapment. Met. CT using ReView technique was of great diagnostic value in superior facet syndrome. (author)

  14. Diagnostic value of lumbar facet joint injection: a prospective triple cross-over study.

    Directory of Open Access Journals (Sweden)

    Uwe Schütz

    Full Text Available The diagnosis "lumbar facet syndrome" is common and often indicates severe lumbar spine surgery procedures. It is doubtful whether a painful facet joint (FJ can be identified by a single FJ block. The aim of this study was to clarify the validity of a single and placebo controlled bilateral FJ blocks using local anesthetics. A prospective single blinded triple cross-over study was performed. 60 patients (31 f, 29 m, mean age 53.2 yrs (22-73 with chronic low back pain (mean pain persistance 31 months, 6 months of conservative treatment without success admitted to a local orthopaedic department for surgical or conservative therapy of chronic LBP, were included in the study. Effect on pain reduction (10 point rating scale was measured. The 60 subjects were divided into six groups with three defined sequences of fluoroscopically guided bilateral monosegmental lumbar FJ test injections in "oblique needle" technique: verum-(local anaesthetic-, placebo-(sodium chloride- and sham-injection. Carry-over and periodic effects were evaluated and a descriptive and statistical analysis regarding the effectiveness, difference and equality of the FJ injections and the different responses was performed. The results show a high rate of non-response, which documents the lack of reliable and valid predictors for a positive response towards FJ blocks. There was a high rate of placebo reactions noted, including subjects who previously or later reacted positively to verum injections. Equivalence was shown among verum vs. placebo and partly vs. sham also. With regard to test validity criteria, a single intraarticular FJ block with local anesthetics is not useful to detect the pain-responsible FJ and therefore is no valid and reliable diagostic tool to specify indication of lumbar spine surgery. Comparative FJ blocks with local anesthetics and placebo-controls have to be interpretated carefully also, because they solely give no proper diagnosis on FJ being main pain

  15. Lumbar Radiofrequency Rhizotomy in Patients with Chronic Low Back Pain Increases the Diagnosis of Sacroiliac Joint Dysfunction in Subsequent Follow-Up Visits

    Science.gov (United States)

    2017-01-01

    Chronic back pain is often a result of coexisting pathologies; secondary causes of pain can become more apparent sources of pain once the primary pathology has been addressed. The objective of our study was to determine if there is an increase in diagnosis of Sacroiliac joint pain following a Lumbar Rhizotomy. A list of patients who underwent Lumbar Radiofrequency during a 6-month period in our clinic was generated. Records from subsequent clinic visits were reviewed to determine if a new diagnosis of SI joint pathology was made. In patients who underwent a recent Lumbar Rhizotomy procedure to treat facetogenic pain, the prevalence of Sacroiliac joint pain increased to 70%. We infer that there is a significant increase in the diagnosis of Sacroiliac joint syndrome following a Lumbar Rhizotomy, potentially due to unmasking of a preexisting condition. In patients presenting with persistent back pain after Lumbar Rhizotomy, the clinician must have a high degree of suspicion for latent Sacroiliac joint pain prior to attributing the pain to block failure. It would be prudent to use >80% relief of pain after a diagnostic medial branch block as a diagnostic criterion for facetogenic pain rather than the currently accepted >50% in order to minimize unmasking of preexisting subclinical pain from the SI joint. PMID:28255260

  16. Lumbar Radiofrequency Rhizotomy in Patients with Chronic Low Back Pain Increases the Diagnosis of Sacroiliac Joint Dysfunction in Subsequent Follow-Up Visits

    Directory of Open Access Journals (Sweden)

    Varun Kumar Rimmalapudi

    2017-01-01

    Full Text Available Chronic back pain is often a result of coexisting pathologies; secondary causes of pain can become more apparent sources of pain once the primary pathology has been addressed. The objective of our study was to determine if there is an increase in diagnosis of Sacroiliac joint pain following a Lumbar Rhizotomy. A list of patients who underwent Lumbar Radiofrequency during a 6-month period in our clinic was generated. Records from subsequent clinic visits were reviewed to determine if a new diagnosis of SI joint pathology was made. In patients who underwent a recent Lumbar Rhizotomy procedure to treat facetogenic pain, the prevalence of Sacroiliac joint pain increased to 70%. We infer that there is a significant increase in the diagnosis of Sacroiliac joint syndrome following a Lumbar Rhizotomy, potentially due to unmasking of a preexisting condition. In patients presenting with persistent back pain after Lumbar Rhizotomy, the clinician must have a high degree of suspicion for latent Sacroiliac joint pain prior to attributing the pain to block failure. It would be prudent to use >80% relief of pain after a diagnostic medial branch block as a diagnostic criterion for facetogenic pain rather than the currently accepted >50% in order to minimize unmasking of preexisting subclinical pain from the SI joint.

  17. Lumbar Radiofrequency Rhizotomy in Patients with Chronic Low Back Pain Increases the Diagnosis of Sacroiliac Joint Dysfunction in Subsequent Follow-Up Visits.

    Science.gov (United States)

    Rimmalapudi, Varun Kumar; Kumar, Sanjeev

    2017-01-01

    Chronic back pain is often a result of coexisting pathologies; secondary causes of pain can become more apparent sources of pain once the primary pathology has been addressed. The objective of our study was to determine if there is an increase in diagnosis of Sacroiliac joint pain following a Lumbar Rhizotomy. A list of patients who underwent Lumbar Radiofrequency during a 6-month period in our clinic was generated. Records from subsequent clinic visits were reviewed to determine if a new diagnosis of SI joint pathology was made. In patients who underwent a recent Lumbar Rhizotomy procedure to treat facetogenic pain, the prevalence of Sacroiliac joint pain increased to 70%. We infer that there is a significant increase in the diagnosis of Sacroiliac joint syndrome following a Lumbar Rhizotomy, potentially due to unmasking of a preexisting condition. In patients presenting with persistent back pain after Lumbar Rhizotomy, the clinician must have a high degree of suspicion for latent Sacroiliac joint pain prior to attributing the pain to block failure. It would be prudent to use >80% relief of pain after a diagnostic medial branch block as a diagnostic criterion for facetogenic pain rather than the currently accepted >50% in order to minimize unmasking of preexisting subclinical pain from the SI joint.

  18. Percutaneous radiofrequency rhizotomy for cervical zygapophyseal joint mediated neck pain: A retrospective review of outcomes in forty-four cases.

    Science.gov (United States)

    Duff, Patricia; Das, Basabjit; McCrory, Connail

    2016-01-01

    Percutaneous radiofrequency (RF) rhizotomy of the medial branches of the dorsal rami from the spinal nerves is the standard treatment for cervical zygapophyseal joint mediated pain. There is a paucity of data regarding the longevity of analgesia following this procedure. To determine the duration of complete pain relief, analgesic consumption and any adverse events following percutaneous cervical RF rhizotomy. Retrospective chart review of patients who had undergone percutaneous cervical RF rhizotomy for zygapophyseal joint mediated neck pain. Patient reviews were undertaken by the pain consultant at 6 weeks, 6 months and 1 year following the procedure. Where follow-up was incomplete, the patient was assumed only to have had pain relief until their last review where complete pain relief had been documented. Analgesic consumption and any adverse events were recorded. The data was analysed using Microsoft Excel®. At 12 months 63.64% of patients were pain free. Median duration of complete pain relief was 52 weeks. Patients who experienced pain relief had ceased using prescription analgesia by their 6 week review. There were no repeat cervical RF rhizotomies, procedure related infections or unplanned hospital admissions. Percutaneous cervical RF rhizotomy is an effective treatment for cervical zygapophyseal joint mediated neck pain.

  19. Effects on the Distal Radioulnar Joint of Ablation of Triangular Fibrocartilage Complex Tears With Radiofrequency Energy.

    Science.gov (United States)

    Huber, Michaela; Loibl, Markus; Eder, Christoph; Kujat, Richard; Nerlich, Michael; Gehmert, Sebastian

    2016-11-01

    This cadaver study investigated the temperature profile in the wrist joint and distal radioulnar joint (DRUJ) during radiofrequency energy (RFE) application for triangular fibrocartilage complex resection. An arthroscopic partial resection of the triangular fibrocartilage complex using monopolar and bipolar RFE was simulated in 14 cadaver limbs. The temperature was recorded simultaneously in the DRUJ and at 6 other anatomic locations of the wrist during RFE application. The mean temperature in the DRUJ was 43.3 ± 8.2°C for the bipolar system in the ablation mode (60 W) and 30.4 ± 3.4°C for the monopolar system in the cut mode (20 W) after 30 seconds. The highest measured temperature in the DRUJ was 54.3°C for the bipolar system and 68.1°C for the monopolar system. The application of RFE for debridement or resection of the triangular fibrocartilage complex in a clinical setting can induce peak temperatures that might cause damage to the cartilage of the DRUJ. Bipolar systems produce higher mean temperatures than monopolar devices. RFE application increases the mean temperature in the DRUJ after 30 seconds to a level that may jeopardize cartilage tissue. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Radiofrequency Neurotomy

    Science.gov (United States)

    ... your specific symptoms. What you can expect Before radiofrequency neurotomy Let your doctor know if you take ... tobacco products the day of your procedure. During radiofrequency neurotomy Radiofrequency neurotomy is an outpatient procedure, so ...

  1. Percutaneous CT-guided interventional procedures in musculoskeletal system (our experience)

    Energy Technology Data Exchange (ETDEWEB)

    Thanos, Loukas E-mail: loutharad@yahoo.com; Mylona, Sophia; Kalioras, Vasilios; Pomoni, Maria; Batakis, Nikolaos

    2004-06-01

    Percutaneous interventional procedures include a broad spectrum of minimal invasive techniques, which are a useful diagnostic and therapeutic tool. In this study we present our experience in CT-guided percutaneous musculoskeletal biopsies, drainages of musculoskeletal abscesses, facet and sacroiliac joint injection and radiofrequency thermal ablation of painful metastases or osteoid osteomas.

  2. Development and Validation of the Faceted Inventory of the Five-Factor Model (FI-FFM).

    Science.gov (United States)

    Watson, David; Nus, Ericka; Wu, Kevin D

    2017-06-01

    The Faceted Inventory of the Five-Factor Model (FI-FFM) is a comprehensive hierarchical measure of personality. The FI-FFM was created across five phases of scale development. It includes five facets apiece for neuroticism, extraversion, and conscientiousness; four facets within agreeableness; and three facets for openness. We present reliability and validity data obtained from three samples. The FI-FFM scales are internally consistent and highly stable over 2 weeks (retest rs ranged from .64 to .82, median r = .77). They show strong convergent and discriminant validity vis-à-vis the NEO, the Big Five Inventory, and the Personality Inventory for DSM-5. Moreover, self-ratings on the scales show moderate to strong agreement with corresponding ratings made by informants ( rs ranged from .26 to .66, median r = .42). Finally, in joint analyses with the NEO Personality Inventory-3, the FI-FFM neuroticism facet scales display significant incremental validity in predicting indicators of internalizing psychopathology.

  3. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  4. Modulation of Cervical Facet Joint Nociception and Pain Attenuates Physical and Psychological Features of Chronic Whiplash: A Prospective Study.

    Science.gov (United States)

    Smith, Ashley Dean; Jull, Gwendolen; Schneider, Geoff M; Frizzell, Bevan; Hooper, Robert A; Sterling, Michele

    2015-09-01

    To investigate changes in clinical (physical and psychological) features of individuals with chronic whiplash-associated disorder who had previously undergone cervical radiofrequency neurotomy at the time point when the effects of radiofrequency neurotomy had dissipated and pain returned. Prospective cohort observational trial of consecutive patients. Tertiary spinal intervention centre in Calgary, Alberta, Canada. A total of 53 consecutive individuals with chronic whiplash-associated disorder. Individuals underwent radiofrequency neurotomy and were assessed before radiofrequency neurotomy, at 1 and 3 months postprocedure, and then after the return of pain (approximately 10 months postprocedure). Quantitative sensory tests (pressure; thermal pain thresholds; brachial plexus provocation test), nociceptive flexion reflex, and motor function (cervical range of movement; craniocervical flexion test) were measured. Self-reported disability, psychological distress, pain catastrophization, and posttraumatic stress disorder symptoms also were measured. Upon the return of pain after radiofrequency neurotomy, levels of disability increased (P .22). There were no significant changes in pressure hyperalgesia (P > .054) or craniocervical flexion test performance (P > .07) after the return of pain. Psychological distress and pain catastrophizing increased significantly after the return of pain (P .13). However, there was no difference in number or severity of posttraumatic stress symptoms after the return of pain (P > .30). Physical and psychological features of chronic whiplash-associated disorder are modulated dynamically with cervical radiofrequency neurotomy. These findings indicate that peripheral nociception is involved in the manifestations of chronic whiplash-associated disorder in this cohort of individuals. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  5. The cervical facet capsule and its role in whiplash injury: a biomechanical investigation.

    Science.gov (United States)

    Winkelstein, B A; Nightingale, R W; Richardson, W J; Myers, B S

    2000-05-15

    Cervical facet capsular strains were determined during bending and at failure in the human cadaver. To determine the effect of an axial pretorque on facet capsular strains and estimate the risk for subcatastrophic capsular injury during normal bending motions. Epidemiologic and clinical studies have identified the facet capsule as a potential site of injury and prerotation as a risk factor for whiplash injury. Unfortunately, biomechanical data on the cervical facet capsule and its role in whiplash injury are not available. Cervical spine motion segments were tested in a pure-moment test frame and the full-field strains determined throughout the facet capsule. Motion segments were tested with and without a pretorque in pure bending. The isolated facet was then elongated to failure. Maximum principal strains during bending were compared with failure strains, by paired t test. Statistically significant increases in principal capsular strains during flexion-extension loading were observed when a pretorque was applied. All measured strains during bending were significantly less than strains at catastrophic joint failure. The same was true for subcatastrophic ligament failure strains, except in the presence of a pretorque. Pretorque of the head and neck increases facet capsular strains, supporting its role in the whiplash mechanism. Although the facet capsule does not appear to be at risk for gross injury during normal bending motions, a small portion of the population may be at risk for subcatastrophic injury.

  6. Surgical treatment of traumatic cervical facet dislocation: anterior, posterior or combined approaches?

    Directory of Open Access Journals (Sweden)

    Catarina C. Lins

    Full Text Available ABSTRACT Surgical treatment is well accepted for patients with traumatic cervical facet joint dislocations (CFD, but there is uncertainty over which approach is better: anterior, posterior or combined. We performed a systematic literature review to evaluate the indications for anterior and posterior approaches in the management of CFD. Anterior approaches can restore cervical lordosis, and cause less postoperative pain and less wound problems. Posterior approaches are useful for direct reduction of locked facet joints and provide stronger fixation from a biomechanical point of view. Combined approaches can be used in more complex cases. Although both anterior and posterior approaches can be used interchangeably, there are some patients who may benefit from one of them over the other, as discussed in this review. Surgeons who treat cervical spine trauma should be able to perform both procedures as well as combined approaches to adequately manage CFD and improve patients’ final outcomes.

  7. Medial branch neurotomy in low back pain

    International Nuclear Information System (INIS)

    Masala, Salvatore; Mammucari, Matteo; Simonetti, Giovanni; Nano, Giovanni; Marcia, Stefano

    2012-01-01

    This study aimed to assess the effectiveness of pulsed radiofrequency medial branch dorsal ramus neurotomy in patients with facet joint syndrome. From January 2008 to April 2010, 92 patients with facet joint syndrome diagnosed by strict inclusion criteria and controlled diagnostic blocks undergone medial branch neurotomy. We did not exclude patients with failed back surgery syndrome (FBSS). Electrodes (20G) with 5-mm active tip were placed under fluoroscopy guide parallel to medial branch. Patients were followed up by physical examination and by Visual Analog Scale and Oswestry Disability Index at 1, 6, and 12 months. In all cases, pain improvement was statistically significant and so quality of life. Three non-FBSS patients had to undergo a second neurotomy because of non-satisfactory pain decrease. Complications were reported in no case. Medial branch radiofrequency neurotomy has confirmed its well-established effectiveness in pain and quality of life improvement as long as strict inclusion criteria be fulfilled and nerve ablation be accomplished by parallel electrode positioning. This statement can be extended also to FBSS patients. (orig.)

  8. Medial branch neurotomy in low back pain

    Energy Technology Data Exchange (ETDEWEB)

    Masala, Salvatore; Mammucari, Matteo; Simonetti, Giovanni [Interventional Radiology and Radiotherapy University ' ' Tor Vergata' ' , Department of Diagnostic and Molecular Imaging, Rome (Italy); Nano, Giovanni [Interventional Radiology and Radiotherapy University ' ' Tor Vergata' ' , Department of Diagnostic and Molecular Imaging, Rome (Italy); University ' ' Tor Vergata' ' , Department of Radiology, Rome (Italy); Marcia, Stefano [S. Giovanni di Dio Hospital, Department of Diagnostic and Molecular Imaging, Cagliari (Italy)

    2012-07-15

    This study aimed to assess the effectiveness of pulsed radiofrequency medial branch dorsal ramus neurotomy in patients with facet joint syndrome. From January 2008 to April 2010, 92 patients with facet joint syndrome diagnosed by strict inclusion criteria and controlled diagnostic blocks undergone medial branch neurotomy. We did not exclude patients with failed back surgery syndrome (FBSS). Electrodes (20G) with 5-mm active tip were placed under fluoroscopy guide parallel to medial branch. Patients were followed up by physical examination and by Visual Analog Scale and Oswestry Disability Index at 1, 6, and 12 months. In all cases, pain improvement was statistically significant and so quality of life. Three non-FBSS patients had to undergo a second neurotomy because of non-satisfactory pain decrease. Complications were reported in no case. Medial branch radiofrequency neurotomy has confirmed its well-established effectiveness in pain and quality of life improvement as long as strict inclusion criteria be fulfilled and nerve ablation be accomplished by parallel electrode positioning. This statement can be extended also to FBSS patients. (orig.)

  9. Faceted Search

    CERN Document Server

    Tunkelang, Daniel

    2009-01-01

    We live in an information age that requires us, more than ever, to represent, access, and use information. Over the last several decades, we have developed a modern science and technology for information retrieval, relentlessly pursuing the vision of a "memex" that Vannevar Bush proposed in his seminal article, "As We May Think." Faceted search plays a key role in this program. Faceted search addresses weaknesses of conventional search approaches and has emerged as a foundation for interactive information retrieval. User studies demonstrate that faceted search provides more

  10. Significance of interfacet distance, facet joint orientation, and lumbar lordosis in spondylolysis.

    Science.gov (United States)

    Chung, Sang-Bong; Lee, Sungjoon; Kim, Hoon; Lee, Sun-Ho; Kim, Eun Sang; Eoh, Whan

    2012-04-01

    The aim of this study is to reveal the association between lumbar spondylolysis and several radiologic parameters, which had been suggested to be significant. The authors examine interfacet distance (IFD), facet joint orientation (FJO), and lumbar segmental lordosis (LSL) all together on the basis of lumbar computed tomography (CT) scan of 35 patients with L5 spondylolysis and 36 unaffected control groups. Thirty-five Korean military recruits, aged 19-23 (mean 20.9 years), were diagnosed as L5 spondylolysis by lumber CT scans. As a control group, 36 male Korean military recruits, aged 18-25 (mean 21.3 years), were reconfirmed as not affected by lumbar spondylolysis by CT scan when they visited our hospital complaining of back pain. This study compares IFD, FJO, and LSL for each lumbar segment between the spondylolytic and unaffected groups. We also propose the use of normal mean data of IFD, FJO, and LSL of lumbar vertebrae from 36 Korean young military recruits because each measurement has power as an absolute value, like data from an osteologic collection in other studies. Comparison of IFD between spondylolytic and unaffected individuals reveals significant differences at the L3, L4, and L5 level (P = 0.0384, P = 0.0219, and P spondylolysis, the increase of IFD from L4 to S1 was less pronounced (P spondylolysis and individuals without pars defect on L5. In the spondylolysis group, and the increase of IFD from L4 to S1 was less pronounced and the LSL at L5-S1 was more lordotic. Copyright © 2011 Wiley Periodicals, Inc.

  11. Radiofrequency neurotomy of the medial branch for the management of lumbar zygapophysial joint pain

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Kim, Hyoung Ihl; Han, Young Min

    2006-01-01

    We wanted to investigate the efficacy of percutaneous radiofrequency (RF) neurotomy of the medial branch for the management of chronic low back pain due to lumbar zygapophysial joint dysfunction. Thirteen patients who had unremitting chronic low back pain for more than 6 months and whose VAS scores were over 7 were selected on the basis of double comparative nerve blocks. The patients consist of three males and 10 females, and their nean age was 67 years. Sensory stimulation was performed to detect the 'pathologic branches' that were responsible for pain generation. RF neurotomy was performed using a lesion generator at 80 C for 90 seconds. The postoperative outcome was classified, depending on the degree of pain reduction, as excellent (≥ 75%), good (50-75%), and poor (<50%). Follow-up evaluation was performed at 6 weeks, 3 months and 6 months after surgery. The mean number of medial branches was 6.2. Eleven patients had bilateral disease and two had unilateral disease. Sensory stimulation was positive in all patients with a mean amplitude of 4.5V (range: 0.15-6 V). The L5 dorsal ramus was the most frequently involved segment, and this was followed by L4, L3 and L2. The number of lesionings for each medial branch was 3.7. The surgical outcome was graded as excellent (53%), good (23%), and poor (24%) after 6 months of follow-up. Transient backaches were noticed in two patients; however, complications were not observed. Recurrences were not demonstrated during the follow-up period. We conclude that RF neurotomy of the medial branches is an efficient method to substantially alleviate the chronic low back pain caused by zygapophysial joint dysfunction

  12. Radiofrequency neurotomy of the medial branch for the management of lumbar zygapophysial joint pain

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Hoon [Bong-Sang Clinic, Seoul (Korea, Republic of); Kim, Hyoung Ihl [Presbyterian Medical Center, Seoul (Korea, Republic of); Han, Young Min [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2006-08-15

    We wanted to investigate the efficacy of percutaneous radiofrequency (RF) neurotomy of the medial branch for the management of chronic low back pain due to lumbar zygapophysial joint dysfunction. Thirteen patients who had unremitting chronic low back pain for more than 6 months and whose VAS scores were over 7 were selected on the basis of double comparative nerve blocks. The patients consist of three males and 10 females, and their nean age was 67 years. Sensory stimulation was performed to detect the 'pathologic branches' that were responsible for pain generation. RF neurotomy was performed using a lesion generator at 80 C for 90 seconds. The postoperative outcome was classified, depending on the degree of pain reduction, as excellent ({>=} 75%), good (50-75%), and poor (<50%). Follow-up evaluation was performed at 6 weeks, 3 months and 6 months after surgery. The mean number of medial branches was 6.2. Eleven patients had bilateral disease and two had unilateral disease. Sensory stimulation was positive in all patients with a mean amplitude of 4.5V (range: 0.15-6 V). The L5 dorsal ramus was the most frequently involved segment, and this was followed by L4, L3 and L2. The number of lesionings for each medial branch was 3.7. The surgical outcome was graded as excellent (53%), good (23%), and poor (24%) after 6 months of follow-up. Transient backaches were noticed in two patients; however, complications were not observed. Recurrences were not demonstrated during the follow-up period. We conclude that RF neurotomy of the medial branches is an efficient method to substantially alleviate the chronic low back pain caused by zygapophysial joint dysfunction.

  13. Radiofrequency ablation of chondroblastoma using a multi-tined expandable electrode system: initial results

    International Nuclear Information System (INIS)

    Tins, Bernhard; Cassar-Pullicino, Victor; McCall, Iain; Cool, Paul; Williams, David; Mangham, David

    2006-01-01

    The standard treatment for chondroblastoma is surgery, which can be difficult and disabling due to its apo- or epiphyseal location. Radiofrequency (RF) ablation potentially offers a minimally invasive alternative. The often large size of chondroblastomas can make treatment with plain electrode systems difficult or impossible. This article describes the preliminary experience of RF treatment of chondroblastomas with a multi-tined expandable RF electrode system. Four cases of CT guided RF treatment are described. The tumour was successfully treated in all cases. In two cases, complications occurred; infraction of a subarticular chondroblastoma in one case and cartilage and bone damage in the unaffected compartment of a knee joint in the other. Radiofrequency treatment near a joint surface threatens the integrity of cartilage and therefore long-term joint function. In weight-bearing areas, the lack of bone replacement in successfully treated lesions contributes to the risk of mechanical failure. Multi-tined expandable electrode systems allow the treatment of large chondroblastomas. In weight-bearing joints and lesions near to the articular cartilage, there is a risk of cartilage damage and mechanical weakening of the bone. In lesions without these caveats, RF ablation appears promising. The potential risks and benefits need to be evaluated for each case individually. (orig.)

  14. Radiofrequency ablation of chondroblastoma using a multi-tined expandable electrode system: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Tins, Bernhard; Cassar-Pullicino, Victor; McCall, Iain [RJAH Orthopaedic and District Hospital, Department of Radiology, Oswestry (United Kingdom); Cool, Paul [RJAH Orthopaedic and District Hospital, Musculoskeletal Tumour Unit, Oswestry (United Kingdom); Williams, David [Hereford Hospital, Department of Orthopaedics, Hereford (United Kingdom); Mangham, David [RJAH Orthopaedic and District Hospital, Department of Pathology, Oswestry (United Kingdom)

    2006-04-15

    The standard treatment for chondroblastoma is surgery, which can be difficult and disabling due to its apo- or epiphyseal location. Radiofrequency (RF) ablation potentially offers a minimally invasive alternative. The often large size of chondroblastomas can make treatment with plain electrode systems difficult or impossible. This article describes the preliminary experience of RF treatment of chondroblastomas with a multi-tined expandable RF electrode system. Four cases of CT guided RF treatment are described. The tumour was successfully treated in all cases. In two cases, complications occurred; infraction of a subarticular chondroblastoma in one case and cartilage and bone damage in the unaffected compartment of a knee joint in the other. Radiofrequency treatment near a joint surface threatens the integrity of cartilage and therefore long-term joint function. In weight-bearing areas, the lack of bone replacement in successfully treated lesions contributes to the risk of mechanical failure. Multi-tined expandable electrode systems allow the treatment of large chondroblastomas. In weight-bearing joints and lesions near to the articular cartilage, there is a risk of cartilage damage and mechanical weakening of the bone. In lesions without these caveats, RF ablation appears promising. The potential risks and benefits need to be evaluated for each case individually. (orig.)

  15. Facet development for a faceted stretched-membrane dish by Solar Kinetics, Inc

    Energy Technology Data Exchange (ETDEWEB)

    Schertz, P.T.; Brown, D.C.; Konnerth, A. III (Solar Kinetics, Inc., Dallas, TX (United States))

    1991-07-01

    A 3.6-meter diameter stretched-membrane optical facet for a parabolic dish has been successfully designed and demonstrated under contract with Sandia National Laboratories. Twelve facets identical to them will be used to make the lightweight reflector of the dish. The project goal of 2.5-mrad surface accuracy was met with each of the two full-sized prototypes, and accuracies of as low as 1.1 mrad were achieved. The facet weight is 11.7 kg/m{sup 2} (2.4lbs/ft{sup 2}). The facet is similar in construction to the successful stretched-membrane heliostat; it has two thin metal membranes attached to a ring. However, the front membrane for this facet is plastically formed at the factor in order to achieve a shorter facet f/D (approximately 3.0). A passive tether restrains the from membrane when not in operation, that is, when the stabilizing vacuum is off. The optical surface is achieved with a silvered-acrylic film laminated to the metal membrane. The facet is expected to cost $55.40/m{sup 2} at a production rate of 10,000 facets per year and $115, 000/m{sup 2}-at a production rate of 500 facets a year. Several key issues have been resolved. Stress concentrations due to seams in the reflective laminate did not cause membrane rupture during forming as they have for dishes with lower focal length-to-diameter ratios. The laminate survived the forming process and simulated operation without deterioration. The optical effect of the tether on the membrane was tested and found to be very small. Most important, highly accurate shapes were obtained using a simple forming procedure. Additional tests are needed to demonstrate process repeatablility and facet performance in typical operating conditions. 18 refs., 36 figs., 11 tabs.

  16. Nonsurgical interventional therapies for low back pain: a review of the evidence for an American Pain Society clinical practice guideline.

    Science.gov (United States)

    Chou, Roger; Atlas, Steven J; Stanos, Steven P; Rosenquist, Richard W

    2009-05-01

    Systematic review. To systematically assess benefits and harms of nonsurgical interventional therapies for low back and radicular pain. Although use of certain interventional therapies is common or increasing, there is also uncertainty or controversy about their efficacy. Electronic database searches on Ovid MEDLINE and the Cochrane databases were conducted through July 2008 to identify randomized controlled trials and systematic reviews of local injections, botulinum toxin injection, prolotherapy, epidural steroid injection, facet joint injection, therapeutic medial branch block, sacroiliac joint injection, intradiscal steroid injection, chemonucleolysis, radiofrequency denervation, intradiscal electrothermal therapy, percutaneous intradiscal radiofrequency thermocoagulation, Coblation nucleoplasty, and spinal cord stimulation. All relevant studies were methodologically assessed by 2 independent reviewers using criteria developed by the Cochrane Back Review Group (for trials) and by Oxman (for systematic reviews). A qualitative synthesis of results was performed using methods adapted from the US Preventive Services Task Force. For sciatica or prolapsed lumbar disc with radiculopathy, we found good evidence that chemonucleolysis is moderately superior to placebo injection but inferior to surgery, and fair evidence that epidural steroid injection is moderately effective for short-term (but not long-term) symptom relief. We found fair evidence that spinal cord stimulation is moderately effective for failed back surgery syndrome with persistent radiculopathy, though device-related complications are common. We found good or fair evidence that prolotherapy, facet joint injection, intradiscal steroid injection, and percutaneous intradiscal radiofrequency thermocoagulation are not effective. Insufficient evidence exists to reliably evaluate other interventional therapies. Few nonsurgical interventional therapies for low back pain have been shown to be effective in

  17. Facet-controlled synthesis and facet-dependent photocatalytic properties of SnO{sub 2} micropolyhedrons

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Gengxia [Key Laboratory of Modern Acoustics, MOE, Institute of Acoustics and Collaborative Innovation Center of Advanced Microstructures, National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China); Wu, Xinglong, E-mail: hkxlwu@nju.edu.cn [Key Laboratory of Modern Acoustics, MOE, Institute of Acoustics and Collaborative Innovation Center of Advanced Microstructures, National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China); Liu, Lizhe; Zhu, Xiaobin [Key Laboratory of Modern Acoustics, MOE, Institute of Acoustics and Collaborative Innovation Center of Advanced Microstructures, National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China); Zhu, Xiaoshu [Center for Analysis and Testing, Nanjing Normal University, Nanjing 210093 (China); Hao, Yanling [Key Laboratory of Modern Acoustics, MOE, Institute of Acoustics and Collaborative Innovation Center of Advanced Microstructures, National Laboratory of Solid State Microstructures, Nanjing University, Nanjing 210093 (China); Chu, Paul K. [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China)

    2015-09-15

    Graphical abstract: - Highlights: • SnO{sub 2} micropolyhedrons with (1 0 1) and (1 0 0) facets at different ratios are fabricated. • The vapor–solid growth mechanism of micropolyhedrons is discussed. • SnO{sub 2} octahedrons with complete (1 0 1) facets show strong photocatalytic activity. • Enhanced photocatalytic activity stems from the facet-dependent surface states. - Abstract: The facet-dependent properties of SnO{sub 2} are of fundamental and practical importance. In this study, by adjusting the deposition temperature during chemical vapor deposition, octahedral SnO{sub 2} with the exposed (1 0 1) facet and two other kinds of SnO{sub 2} polyhedrons with (1 0 1) and (1 0 0) facets with different ratios are fabricated controllably based on the vapor–solid growth mechanism. A slight increase in the deposition temperature from 1030 to 1070 °C decreases the surface energy of the reduced (1 0 1) facet with Sn termination, leading to the formation of polyhedrons with different area ratios of (1 0 1) to (1 0 0) facets. By adopting the terephthalic acid fluorescent method, the SnO{sub 2} octahedrons are demonstrated to have the strongest photocatalytic activity due to the formation of surface states induced by 5s electrons of bivalent Sn on the (1 0 1) surface. The results reveal that the photocatalytic properties of SnO{sub 2} microcrystals can be enhanced by facet-controlled synthesis.

  18. The sacroiliac joint: anatomy, physiology and clinical significance.

    Science.gov (United States)

    Forst, Stacy L; Wheeler, Michael T; Fortin, Joseph D; Vilensky, Joel A

    2006-01-01

    The sacroiliac joint (SIJ) is a putative source of low back pain. The objective of this article is to provide clinicians with a concise review of SIJ structure and function, diagnostic indicators of SIJ-mediated pain, and therapeutic considerations. The SIJ is a true diarthrodial joint with unique characteristics not typically found in other diarthrodial joints. The joint differs with others in that it has fibrocartilage in addition to hyaline cartilage, there is discontinuity of the posterior capsule, and articular surfaces have many ridges and depressions. The sacroiliac joint is well innervated. Histological analysis of the sacroiliac joint has verified the presence of nerve fibers within the joint capsule and adjoining ligaments. It has been variously described that the sacroiliac joint receives its innervation from the ventral rami of L4 and L5, the superior gluteal nerve, and the dorsal rami of L5, S1, and S2, or that it is almost exclusively derived from the sacral dorsal rami. Even though the sacroiliac joint is a known putative source of low back and lower extremity pain, there are few findings that are pathognomonic of sacroiliac joint pain. The controlled diagnostic blocks utilizing the International Association for the Study of Pain (IASP) criteria demonstrated the prevalence of pain of sacroiliac joint origin in 19% to 30% of the patients suspected to have sacroiliac joint pain. Conservative management includes manual medicine techniques, pelvic stabilization exercises to allow dynamic postural control, and muscle balancing of the trunk and lower extremities. Interventional treatments include sacroiliac joint, intra-articular joint injections, radiofrequency neurotomy, prolotherapy, cryotherapy, and surgical treatment. The evidence for intra-articular injections and radiofrequency neurotomy has been shown to be limited in managing sacroiliac joint pain.

  19. Chronic whiplash-associated disorder and traumatic cerebrospinal fluid leak. Analysis of cases with radioisotope cisternography, epidural blood patch, and cervical facet joint blocks

    International Nuclear Information System (INIS)

    Ishikawa, Shinichi; Kobayashi, Hiroyuki; Takahara, Hiroshi; Kojo, Shigeru; Hashimoto, Hidenori; Moriyama, Eiji; Nishida, Ayumi

    2008-01-01

    This paper describes RI cisternographic (RIC) examinations of whiplash-associated disorder (WAD) and results of their treatment with nerve block and epidural blood patch (EBP) conducted in authors' facilities. Subjects were 40 chronic (av. symptomatic period of 3.1 y) WAD patients (av. age 34 y) with traffic (28 cases), sports (7) and falling (5) causes with complication of suspicious cerebrospinal fluid (CSF) leak. RIC was done 2.5-24 hr after injection of 37 MBq of 111 In-diethylenetriamine pentaacetic acid (DTPA) in the medullary space through epidural puncturing needle. Positive finding of clear leak or early accumulation of RI in the bladder was seen in 21 cases and negative, in 19. Positive patients had significantly higher rates of headache, abnormal vision and fatigue than negative ones. EBP was conducted through X-ray to all positive patients and to negative ones with strongly suspicious leak complication (7 cases), which resulted in improvement of symptoms like headache and vision in the former, but no improvement in the latter cases. Repeated RIC of the patients with poor improvement in the former was suggested effective for judgment of repetition of EBP treatment. Cervical facet joint blocks were found effective in cases with posterior cervical pain. Symptoms in WAD accompanying headache should be differentially diagnosed whether it is derived from posttraumatic CSF leak or from pain due to cervical facet arthritis. (R.T.)

  20. Effects of Facet Joint Injection Reducing the Need for Percutaneous Vertebroplasty in Vertebral Compression Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Im, Tae Seong; Lee, Joon Woo; Lee, Eugene; Kang, Yusuhn; Ahn, Joong Mo, E-mail: joongmoahn@gmail.com; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology (Korea, Republic of)

    2016-05-15

    ObjectiveTo evaluate the effects of facet joint injection (FJI) reducing the need for percutaneous vertebroplasty (PVP) in cases of vertebral compression fracture (VCF).Materials and MethodsA total of 169 patients who were referred to the radiology department of our institution for PVP between January 2011 and December 2014 were retrospectively evaluated. The effectiveness of FJI was evaluated by the proportion of patients who cancelled PVP and who experienced reduced pain. In addition, by means of medical chart and MRI review, those clinical factors (age, sex, history of trauma, amount of injected steroids and interval days elapsed between VCF and FJI) and MR image factors (kyphosis angle, height loss, single or multiple level of VCF, burst fracture, central canal compromise, posterior element injury) that were believed to be significant for the effectiveness of FJI were statistically analysed.ResultsIn the 26 patients with FJI prior to PVP, six (23 %) patients cancelled PVP with considerable improvement in reported pain. In the 20 patients with PVP after FJI, improvement in pain after FJI was reported by six patients, resulting in a total of 12 patients (46 %) who experienced reduced pain after FJI. Clinical factors and MR image factors did not show any statistically significant difference between those groups, divided by PVP cancellation and by improvement of pain.ConclusionAfter FJI prior to PVP, about one quarter of patients cancelled PVP due to reduced pain and overall about half of the patients experienced reduced pain.

  1. Sacroiliac Joint Interventions.

    Science.gov (United States)

    Soto Quijano, David A; Otero Loperena, Eduardo

    2018-02-01

    Sacroiliac joint (SIJ) pain is an important cause of lower back problems. Multiple SIJ injection techniques have been proposed over the years to help in the diagnosis and treatment of this condition. However, the SIJ innervation is complex and variable, and truly intra-articular injections are sometimes difficult to obtain. Different sacroiliac joint injections have shown to provide pain relief in patients suffering this ailment. Various techniques for intraarticular injections, sacral branch blocks and radiofrequency ablation, both fluoroscopy guided and ultrasound guided are discussed in this paper. Less common techniques like prolotherapy, platelet rich plasma injections and botulism toxin injections are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Sacroiliac joint dysfunction.

    Science.gov (United States)

    Ilaslan, Hakan; Arslan, Ahmet; Koç, Omer Nadir; Dalkiliç, Turker; Naderi, Sait

    2010-07-01

    Sacroiliac joint dysfunction is a disorder presenting with low back and groin pain. It should be taken into consideration during the preoperative differential diagnosis of lumbar disc herniation, lumbar spinal stenosis and facet syndrome. Four cases with sacroiliac dysfunction are presented. The clinical and radiological signs supported the evidence of sacroiliac dysfunction, and exact diagnosis was made after positive response to sacroiliac joint block. A percutaneous sacroiliac fixation provided pain relief in all cases. The mean VAS scores reduced from 8.2 to 2.2. It is concluded that sacroiliac joint dysfunction diagnosis requires a careful physical examination of the sacroiliac joints in all cases with low back and groin pain. The diagnosis is made based on positive response to the sacroiliac block. Sacroiliac fixation was found to be effective in carefully selected cases.

  3. Indian Hedgehog signaling pathway members are associated with magnetic resonance imaging manifestations and pathological scores in lumbar facet joint osteoarthritis

    Science.gov (United States)

    Shuang, Feng; Zhou, Ying; Hou, Shu-Xun; Zhu, Jia-Liang; Liu, Yan; Zhang, Chun-Li; Tang, Jia-Guang

    2015-05-01

    Indian Hedgehog (HH) has been shown to be involved in osteoarthritis (OA) in articular joints, where there is evidence that Indian HH blockade could ameliorate OA. It seems to play a prominent role in development of the intervertebral disc (IVD) and in postnatal maintenance. There is little work on IHH in the IVD. Hence the aim of the current study was to investigate the role of Indian Hedgehog in the pathology of facet joint (FJ) OA. 24 patients diagnosed with lumbar intervertebral disk herniation or degenerative spinal stenosis were included. Preoperative magnetic resonance imaging (MRI) and Osteoarthritis Research Society International (OARSI) histopathology grading system was correlated to the mRNA levels of GLI1, PTCH1, and HHIP in the FJs. The Weishaupt grading and OARSI scores showed high positive correlation (r = 0.894) (P < 0.01). MRI Weishaupt grades showed positive correlation with GLI1 (r = 0.491), PTCH1 (r = 0.444), and HHIP (r = 0.654) mRNA levels (P < 0.05 in each case). OARSI scores were also positively correlated with GLI1 (r = 0. 646), PTCH1 (r = 0. 518), and HHIP (r = 0.762) mRNA levels (P < 0.01 in each case). Cumulatively our findings indicate that Indian HH signaling is increased in OA and is perhaps a key component in OA pathogenesis and progression.

  4. FACET

    International Nuclear Information System (INIS)

    Cole, C.W.; Banszky, I.J.

    1989-01-01

    The merits of using commercially available software packages versus in-house software and databases are frequently assessed by cost engineers in consulting, contracting and operating companies alike. There is no consensus on which approach is better as each company has individual requirements that are better provided for by one or the other alternative. This paper describes Mobil Oil Canada's FACET (Facilities Cost Estimating Techniques) programs and provides a framework for building any successful in-house PC-based cost estimating and control system. The FACET series of programs enables detailed cost estimates to be quickly developed from relatively conceptual cost data and allows project cost estimates to be compared with actual costs as the project proceeds

  5. Radiofrequency Procedures to Relieve Chronic Knee Pain: An Evidence-Based Narrative Review.

    Science.gov (United States)

    Bhatia, Anuj; Peng, Philip; Cohen, Steven P

    2016-01-01

    Chronic knee pain from osteoarthritis or following arthroplasty is a common problem. A number of publications have reported analgesic success of radiofrequency (RF) procedures on nerves innervating the knee, but interpretation is hampered by lack of clarity regarding indications, clinical protocols, targets, and longevity of benefit from RF procedures. We reviewed the following medical literature databases for publications on RF procedures on the knee joint for chronic pain: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Google Scholar up to August 9, 2015. Data on scores for pain, validated scores for measuring physical disability, and adverse effects measured at any timepoint after 1 month following the interventions were collected, analyzed, and reported in this narrative review. Thirteen publications on ablative or pulsed RF treatments of innervation of the knee joint were identified. A high success rate of these procedures in relieving chronic pain of the knee joint was reported at 1 to 12 months after the procedures, but only 2 of the publications were randomized controlled trials. There was evidence for improvement in function and a lack of serious adverse events of RF treatments. Radiofrequency treatments on the knee joint (major or periarticular nerve supply or intra-articular branches) have the potential to reduce pain from osteoarthritis or persistent postarthroplasty pain. Ongoing concerns regarding the quality, procedural aspects, and monitoring of outcomes in publications on this topic remain. Randomized controlled trials of high methodological quality are required to further elaborate role of these interventions in this population.

  6. Superior facet syndrome. Findings on metrizamide CT myelography

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Yoshichika; Igarashi, Seishi; Koyama, Tsunemaro

    1985-02-01

    Sciatica caused by root entrapment in the lateral recess was named superior facet syndrome by Epstein in 1972. Few reports on this subject based on large numbers of cases have been documented to date. Of the patients with sciatica, 32 patients were diagnosed to have root entrapment at the lateral recess L5 or/and S1 lumbar spine. Out of 32 patients, 20 patients were operated on and the lateral entrapment was recognized in all of surgical cases. Neuroradiological findings, especially of metrizamide CT (met. CT), were documented in detail. Thirty two patients were classified in three types according to radiological findings. They were congenital or developmental, degenerative, and combined type, respectively. Fourteen cases belonged to the congenital type, 13 to the degenerative and 5 to the combined type. Each group had the mean ages of 23.4, 53.8, and 36.8 years old, respectively. Of 32 cases the entrapment occured in 47 L5 roots and 11 S1 roots. There was no remarkable laterality. In operation the unroofing of the lateral recess were done and the sciatica subsided postoperatively in all of surgical cases. Met. CT revealed extreme medial protrusion of the superior articular joint in 18 of 24 cases(75%) and none filling of the root in the lateral recess in 21 of 24 cases (87.5%). In the degenerative type, met. CT showed some degenerative changes that were hypertrophy or deformity of the articular joints and spur formation of the vertebral body. In contrast to met. CT, metrizamide myelography revealed only slight changes, which were poor filling of the root before it turned out the pedicle of lateral compression of the root. In plain films or lumbar spine articular joints at Lsub(4/5) were formed in coronal plane in 69% of cases of the L5 root entrapment. Met. CT using ReView technique was of great diagnostic value in superior facet syndrome.

  7. WORKSHOPS: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991

  8. WORKSHOPS: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-01-15

    In the continual push towards higher energy particle beams, superconducting radiofrequency techniques now play a vital role, highlighted in the fifth workshop on radiofrequency superconductivity, held at DESY from 19 - 24 August 1991.

  9. Facets of Facebook: Use and Users

    OpenAIRE

    2016-01-01

    The debate on Facebook raises questions about the use and users of this information service. This collected volume gathers a broad spectrum of social science and information science articles about Facebook.Facebook has many facets, and we just look forward above all to the use and users. The facet of users has sub-facets, such as different age, sex, and culture. The facet of use consists of sub-facets of privacy behavior after the Snowden affair, dealing with friends, unfriending and becoming...

  10. Radiofrequency Ablation of Lung Tumors

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiofrequency Ablation (RFA) / Microwave Ablation (MWA) of Lung Tumors ... and Microwave Ablation of Lung Tumors? What are Radiofrequency and Microwave Ablation of Lung Tumors? Radiofrequency ablation, ...

  11. Correlation between facet tropism and lumbar degenerative disease: a retrospective analysis.

    Science.gov (United States)

    Gao, Tian; Lai, Qi; Zhou, Song; Liu, Xuqiang; Liu, Yuan; Zhan, Ping; Yu, Xiaolong; Xiao, Jun; Dai, Min; Zhang, Bin

    2017-11-22

    The aim of this study was to investigate the correlation between facet tropism and spinal degenerative diseases, such as degenerative lumbar spondylolisthesis, degenerative lumbar scoliosis, and lumbar disc herniation. This study retrospectively analysed clinical data from the Department of Orthopaedics at The First Affiliated Hospital of Nanchang University. Ninety-two patients were diagnosed with lumbar spondylolisthesis, 64 patients with degenerative scoliosis, and 86 patients with lumbar disc herniation between 1 October 2014 and 1 October 2016. All patients were diagnosed using 3.0 T magnetic resonance imaging and underwent conservative or operative treatment. Facet tropism was defined as greater than a ten degree between the facet joint angles on both sides. For L3-L4 degenerative lumbar spondylolisthesis, one out of six cases had tropism compared to seven out of the 86 controls (p = 0.474). At the L4-L5 level, 17/50 cases had tropism compared to 4/42 cases in the control group (p = 0.013). At the L5-S1 level, 18/36 cases had tropism compared to 7/56 controls (p = 0.000). For degenerative lumbar scoliosis at the L1-L5 level, 83/256 cases had tropism as compared to 36/256 controls (p = 0.000). For L3-L4 lumbar disc herniation two out of eight cases had tropism compared to 14/78 controls (p = 0.625). At the L4-L5 level, 19/44 cases had tropism compared to four out of 42 controls (p = 0.001). At the L5-S1 level, 24/34 cases had tropism compared to 10/52 controls (p = 0.000). At the L4-5 and L5-S1 levels, facet tropism is associated with degenerative spondylolisthesis. In the degenerative lumbar scoliosis group, the number of case with facet tropism was significantly higher than that of the control group. Facet tropism was associated with lumbar disc herniation at the L4-5 and L5-S1 levels. Overall, in these three lumbar degenerative diseases, facet tropism is a common phenomenon.

  12. Distraction of facets with intraarticular spacers as treatment for lumbar canal stenosis: report on a preliminary experience with 21 cases.

    Science.gov (United States)

    Goel, Atul; Shah, Abhidha; Jadhav, Madan; Nama, Santhosh

    2013-12-01

    The authors report their experience in treating 21 patients by using a novel form of treatment of lumbar degenerative disease that leads to canal stenosis. The surgery involved distraction of the facets using specially designed Goel intraarticular spacers and was aimed at arthrodesis of the spinal segment in a distracted position. The operation is based on the premise that subtle and longstanding facet instability, joint space reduction, and subsequent facet override had a profound and primary influence in the pathogenesis of degenerative lumbar canal stenosis. The surgical technique and the rationale for treatment are discussed. Between April 2006 and January 2011, 21 cases of lumbar degenerative disease resulting in characteristic lumbar canal stenosis were treated in the authors' department with the proposed technique. The patients were prospectively analyzed. There were 15 men and 6 women who ranged in age from 48 to 71 years (mean 58 years). Nine patients underwent 1-level and 12 patients underwent 2-level treatment. Surgery involved wide opening of the articular joint, denuding of the articular capsule/endplate cartilage, distraction of the facets, and forced impaction of Goel intraarticular spacers. Bone graft pieces obtained by sectioning the spinous processes were placed within and over the joint and in the midline over the adequately prepared host area of laminae. The Oswestry Disability Index and visual analog scale were used to clinically assess the patients before and after surgery and at follow-up. The alterations in the physical architecture of spinal canal and intervertebral foramen dimensions were evaluated before and after placement of the intrafacet implant and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of local back pain and radiculopathy. Impaction of spacers within the facet joints resulted in an increase in the spinal canal and intervertebral root canal dimensions (mean 2.33 mm), reduction

  13. Facet Effusion without Radiographic Instability Has No Effect on the Outcome of Minimally Invasive Decompression Surgery.

    Science.gov (United States)

    Tamai, Koji; Kato, Minori; Konishi, Sadahiko; Matsumura, Akira; Hayashi, Kazunori; Nakamura, Hiroaki

    2017-02-01

    Retrospective cohort study. Lumbar segmental instability is a key factor determining whether decompression alone or decompression and fusion surgery is required to treat lumbar spinal stenosis (LSS). Some recent reports have suggested that facet joint effusion is correlated with spinal segmental instability. The aim of this study is to report the effect of facet effusion without radiographic segmental instability on the outcome of less-invasive decompression surgery for LSS. Seventy-nine patients with LSS (32 women, mean age: 69.1 ± 9.1 years) who had no segmental instability on dynamic radiographs before undergoing L4-L5 microsurgical decompression and who were followed for at least 2 years postoperatively were analyzed. They were divided into three groups on the basis of the existence and size of L4-L5 facet effusion using preoperative magnetic resonance imaging: grade 0 had no effusion ( n  = 31), grade 1 had measurable effusion ( n  = 35), and grade 2 had large effusion ( n  = 13). Japanese Orthopedics Association (JOA) score, visual analog scale (VAS), and the Short-Form (SF)-36 scores were recorded preoperatively and 12 and 24 months postoperatively. JOA score; VAS of low back pain, leg pain, and numbness; and SF-36 (physical component summary and mental component summary) scores did not differ significantly between the three groups in every terms ( p  = 0.921, 0.996, 0.950, 0.693, 0.374, 0.304, and 0.624, respectively, at final follow-up). In the absence of radiographic instability, facet joint effusion has no effect on the outcome of less-invasive decompression surgery.

  14. Facetal distraction as treatment for single- and multilevel cervical spondylotic radiculopathy and myelopathy: a preliminary report.

    Science.gov (United States)

    Goel, Atul; Shah, Abhidha

    2011-06-01

    The authors discuss their successful preliminary experience with 36 cases of cervical spondylotic disease by performing facetal distraction using specially designed Goel cervical facet spacers. The clinical and radiological results of treatment are analyzed. The mechanism of action of the proposed spacers and the rationale for their use are evaluated. Between 2006 and February 2010, 36 patients were treated using the proposed technique. Of these patients, 18 had multilevel and 18 had single-level cervical spondylotic radiculopathy and/or myelopathy. The average follow-up period was 17 months with a minimum of 6 months. The Japanese Orthopaedic Association classification system, visual analog scale (neck pain and radiculopathy), and Odom criteria were used to monitor the clinical status of the patient. The patients were prospectively analyzed. The technique of surgery involved wide opening of the facet joints, denuding of articular cartilage, distraction of facets, and forced impaction of Goel cervical facet spacers into the articular cavity. Additionally, the interspinous process ligaments were resected, and corticocancellous bone graft from the iliac crest was placed and was stabilized over the adjoining laminae and facets after adequately preparing the host bone. Eighteen patients underwent single-level, 6 patients underwent 2-level, and 12 patients underwent 3-level treatment. The alterations in the physical architecture of spine and canal dimensions were evaluated before and after the placement of intrafacet joint spacers and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of pain, radiculopathy, and myelopathy. Analysis of radiological features suggested that the distraction of facets with the spacers resulted in an increase in the intervertebral foraminal dimension (mean 2.2 mm), an increase in the height of the intervertebral disc space (range 0.4-1.2 mm), and an increase in the interspinous distance (mean 2

  15. Vacuum pumping system for the JT-60 radio-frequency heating system

    International Nuclear Information System (INIS)

    Yokokura, Kenji; Ikeda, Yoshitaka; Imai, Tuyoshi; Suganuma, Kazuaki; Nagashima, Takashi

    1988-01-01

    The basic design requirements set up for the JT-60 radio-frequency heating system included: (1) rapid pumping of gas released upon application of a radio-frequency power to maintain the pressure in the launchers at 10 -2 - 10 -3 Pa or less, (2) incorporation of a gas analysis system that can operate under a strong field and high pressure (>10 -2 Pa) to permit remote controlled data collection and processing, and (3) low cost, multiple functions and high reliability. The vacuum pumping system, consisting of three units for low hybrid radio-frequency (LHRF) and one unit for ion cyclotron radio-frequency (ICRF), is connected to each launcher provided at the four ports of JT-60. The LHRF unit is composed of a main pump, an alumina joint for electrical insulation from the launcher, a metallic gate valve for isolation from the JT-60 vacuum region, and various vacuum gauges. Only a turbo-molecular pump is used for the ICRF system because a large-scale differential pumping is not required. A gas measuring system is incorporated which consists of a mass filter, personal computer, turbo-molecular pump, and variable flow valve equipped with an APG control. This system is designed to identify and make use of gas impurities released during the launcher aging process. The control system employed consists of a personal computer, interlock control board, data logger and other devices such as vacuum gages. (Nogami, K.)

  16. Quantum mechanical facets of chemical bonds

    International Nuclear Information System (INIS)

    Daudel, R.

    1976-01-01

    To define the concept of bond is both a central problem of quantum chemistry and a difficult one. The concept of bond appeared little by little in the mind of chemists from empirical observations. From the wave-mechanical viewpoint it is not an observable. Therefore there is no precise operator associated with that concept. As a consequence there is not a unique approach to the idea of chemical bond. This is why it is preferred to present various quantum mechanical facets, e.g. the energetic facet, the density facet, the partitioning facet and the functional facet, of that important concept. (Auth.)

  17. Radiofrequency ablation of osteoid osteoma

    NARCIS (Netherlands)

    Vanderschueren, Geert Maria Joris Michael

    2009-01-01

    The main purpose of this thesis was to evaluate the effectiveness and safety of CT-guided radiofrequency ablation for the treatment of spinal and non-spinal osteoid osteomas. Furthermore, the technical requirements needed for safe radiofrequency ablation and the clinical outcome after radiofrequency

  18. The Variations in Calcaneal Articular Facets In North Indian Population and its Clinical Implication

    Directory of Open Access Journals (Sweden)

    Seema

    2012-01-01

    Full Text Available Aims and Objectives- To know the most common type of calcanei in North Indian population and itsclinical importance. There are three articular facets on superior surface of calcaneus- anterior, middle andposterior. Three types of calcanei are noted according to number and arrangement of the articular facets-type A, B and C. Methodology - The present studywas done on 300 dry adult human calcanei of unknownsex taken from Department of Anatomy Sri Guru Ram Das Institute of Medical Sciences and ResearchVallah (Amritsar. Results- In our study Type B was found as the most common type. Type A is the nextmost common. Interpretation- The talocalcaneal joint is important in arthritis and coalition, flat foot, valgus deformity, congenital anomalies and intra articular fractures.

  19. Intra-articular calcaneal fractures: effect of open reduction and internal fixation on the contact characteristics of the subtalar joint.

    Science.gov (United States)

    Mulcahy, D M; McCormack, D M; Stephens, M M

    1998-12-01

    Intra-articular calcaneal fractures are associated with significant long-term morbidity, and considerable controversy exists regarding the optimum method of treating them. The contact characteristics in the intact subtalar joint were determined at known loads and for different positions of the ankle and subtalar joint, using pressure-sensitive film (Super Low; Fuji, Itochu Canada Ltd, Montreal, Quebec). We measured the contact area to joint area ratio (pressure > 5 kg force/cm2 [kgf/cm2]) which normalizes for differences in joint size and the ratio of high pressure zone (>20 kgf/cm2) as a reflection of overall increase in joint pressure. Three simulated fracture patterns were then created and stabilized with either 1 or 2 mm of articular incongruity. Eight specimens were prepared with a primary fracture line through the posterior facet, eight with a joint depression-type fracture, and six with a central joint depression fracture. A measure of 1 to 2 mm of incongruity in the posterior facet for all three fracture patterns produced significant unloading of the depressed fragment, with a redistribution of the overall pattern of pressure distribution to parts of the facet that were previously unloaded.

  20. Association of facet tropism and progressive facet arthrosis after lumbar total disc replacement using ProDisc-L.

    Science.gov (United States)

    Shin, Myung-Hoon; Ryu, Kyeong-Sik; Hur, Jung-Woo; Kim, Jin-Sung; Park, Chun-Kun

    2013-08-01

    The purpose of this retrospective study was to examine the association of facet tropism and progressive facet arthrosis (PFA) after lumbar total disc replacement (TDR) surgery using ProDisc-L. A total of 51 segments of 42 patients who had undergone lumbar TDR using ProDisc-L between October 2003 and July 2007 and completed minimum 36-month follow-up period were retrospectively reviewed. The changes of facet arthrosis were categorized as non-PFA and PFA group. Comparison between non-PFA and PFA group was made according to age, sex, mean follow-up duration, grade of preoperative facet arthrosis, coronal and sagittal prosthetic position and degree of facet tropism. Multiple logistic regression analysis was also performed to analyze the effect of facet tropism on the progression of facet arthrosis. The mean age at the surgery was 44.43 ± 11.09 years and there were 16 males and 26 females. The mean follow-up period was 53.18 ± 15.79 months. Non-PFA group was composed of 19 levels and PFA group was composed of 32 levels. Age at surgery, sex proportion, mean follow-up period, level of implant, grade of preoperative facet arthrosis and coronal and sagittal prosthetic position were not significantly different between two groups (p = 0.264, 0.433, 0.527, 0.232, 0.926, 0.849 and 0.369, respectively). However, PFA group showed significantly higher degree of facet tropism (7.37 ± 6.46°) than that of non-PFA group (3.51 ± 3.53°) and p value was 0.008. After adjustment for age, sex and coronal and sagittal prosthetic position, multiple logistic regression analysis revealed that facet tropism of more than 5° was the only significant independent predictor of progression of facet arthrosis (odds ratio 5.39, 95 % confidence interval 1.251-19.343, p = 0.023). The data demonstrate that significant higher degree of facet tropism was seen in PFA group compared with non-PFA group and facet tropism of more than 5° had a significant association with PFA after TDR using ProDisc-L.

  1. The hamatolunate facet: characterization and association with cartilage lesions - magnetic resonance arthrography and anatomic correlation in cadaveric wrists

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, C.W.A. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States); Orthopedic University Hospital Balgrist, Department of Radiology, Forchstrasse 340, 8008 Zurich (Switzerland); Theumann, N.H.; Chung, C.B.; Trudell, D.J.; Resnick, D. [Department of Radiology, Veterans Administration Medical Center, 3350 La Jolla Village Dr., San Diego, CA 92161 (United States)

    2002-08-01

    The objective of this study was to characterize the appearance of the hamatolunate facet using high-resolution magnetic resonance (MR) arthrography in cadavers and to correlate the presence of this anatomic variant with the presence of osteoarthritis in the wrist. High-resolution MR images of 22 cadaveric wrist specimens were obtained after tri-compartmental arthrography. Two readers in consensus analyzed the MR images and recoded the presence or absence of a hamatolunate facet. Geometric characteristics and cartilage and ligament integrity were analyzed. A third reader, who was blinded to the purpose of the study, recorded cartilage lesions of all the bones of the proximal and distal carpal rows. A hamatolunate facet was present in 11 of 22 wrists (50%). The mean coronal size of the lunate facet at the lunate (type II lunate) was 4.5 mm (range, 2-6 mm). The highest frequencies of cartilage lesions were seen in the scapho-trapezio-trapezoid joint (45.5%) and at the proximal pole of the hamate (54.4% and 40.9% for consensus reading/blinded reading, respectively). In cases with a hamatolunate facet, the frequency of cartilage lesions in the proximal pole of the hamate was 81.8% and 63.6% versus 27.3% and 18.2% without such a facet (chi-squared, P=0.01/P=0.03). No correlation of the presence of a hamatolunate facet with interosseous ligament tears or lesions of the triangular fibrocartilage was seen. In conclusion, the hamatolunate facet is a very common anatomic variant. The presence of a hamatolunate facet is associated with cartilage damage in the proximal pole of the hamate. (orig.)

  2. Lumbar Facet Tropism: A Comprehensive Review.

    Science.gov (United States)

    Alonso, Fernando; Kirkpatrick, Christina M; Jeong, William; Fisahn, Christian; Usman, Sameera; Rustagi, Tarush; Loukas, Marios; Chapman, Jens R; Oskouian, Rod J; Tubbs, R Shane

    2017-06-01

    Scattered reports exist in the medical literature regarding facet tropism. However, this finding has had mixed conclusions regarding its origin and impact on the normal spine. We performed a literature review of the anatomy, embryology, biomechanics, and pathology related to lumbar facet tropism. Facet tropism is most commonly found at L4-L5 vertebral segments and there is some evidence that this condition may lead to facet degenerative spondylolisthesis, intervertebral disc disease, and other degenerative conditions. Long-term analyses of patients are necessary to elucidate relationships between associated findings and facet tropism. In addition, a universally agreed definition that is more precise should be developed for future investigative studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Morphometric analysis of the cervical facets and the feasibility, safety, and effectiveness of Goel inter-facet spacer distraction technique

    Directory of Open Access Journals (Sweden)

    Abhidha Shah

    2014-01-01

    Full Text Available Aim: Quantitative anatomy of the facets of the sub-axial cervical spine was performed. The purpose of the evaluation was to determine the feasibility of insertion of Goel inter-facetal articular spacers in the sub-axial cervical spine. Only few studies detailing the morphometry of the facets are available in the literature. Materials and Methods: Ten cervical vertebrae from C3 to C7 with a total of 20 facets were evaluated by the author. The anatomic parameters studied were the height, width, thickness, shape, orientation, and inclination of each of the superior and inferior facets. The alterations in a number of intervertebral segmental distances were measured before and after spacer insertion. The distance of the inferior facet from the foramen tranversarium, spinal canal, and neural foramina was measured to assess safety of spacer insertion with respect to the vertebral artery and neural structures. Results: The height, width and thickness of the superior facets from C3 to C7 ranged from 6 to 12 mm, 8 to 12 mm, and 2.5 to 6 mm, respectively. The inferior facets had an average height of 10.5 mm, average width of 11.2 mm and average thickness of 3.5 mm. The inclination of the superior facets with respect to the transverse plane ranged from 22° to 45° and that of the inferior facets ranged from 29° to 53°. The distance of the anterior margin of the inferior facet from the posterior border of the foramen transversium ranged from 5 to 7 mm. This distance was maximum at C3 level, then decreased at C4 and remained constant from C5 to C7. Conclusion: This anatomic evaluation aided in understanding the morphology of the cervical facets and the suitability of the cervical facetal articular cavity for insertion of spacers.

  4. Does increased femoral antetorsion predispose to cartilage lesions of the patellofemoral joint?

    Science.gov (United States)

    Oppermann, Johannes; Bredow, Jan; Wissusek, Boris; Spies, Christian Karl; Boese, Christoph Kolja; Chang, Shi-Min; Eysel, Peer; Dargel, Jens

    2017-09-01

    The purpose of this study was to investigate whether there was a relationship between femoral neck antetorsion and the presence and pattern of osteoarthritis of the patellofemoral joint. It was hypothesized that an increased femoral neck antetorsion (1) correlates with osteoarthritic changes of the lateral facet of the patellofemoral joint and (2) correlates with an increased lateral trochlear height and a decreased sulcus angle. Seventy-eight formalin-embedded cadaveric lower extremities from thirty-nine subjects with a median age of 74 years (range 60-88) were used. Surrounding soft tissues of the lower limb were removed. The femoral neck antetorsion was measured and referenced to the transepicondylar axis and the posterior condylar line. The height of the medial and lateral facet of the trochlea and the sulcus angle was measured. The location and the degree of patellofemoral cartilage degeneration were recorded. A Pearson's correlation analysis was performed to correlate the femoral neck antetorsion with the measured knee parameters. No significant correlation could be found between the femoral antetorsion and cartilage degeneration of the lateral patellofemoral joint (n.s.), the height of the lateral trochlea (n.s.) and the sulcus angle (n.s.). This study could not document that the femoral neck antetorsion and subsequent internal rotation of the distal femur correlated with the degree of degeneration of the lateral facet of the patellofemoral joint. Clinically, femoral internal rotation may play a minor role in the development of lateral patellofemoral joint degeneration.

  5. Mindfulness facets and Big Five personality facets in persons with recurrent depression in remission

    NARCIS (Netherlands)

    Spinhoven, Philip; Huijbers, Marloes J.; Zheng, Yixia; Ormel, Johan; Speckens, Anne E. M.

    2017-01-01

    Studies examining mindfulness in relation to personality traits have been mainly conducted in non-clinical samples and resulted in mixed findings. The present cross-sectional study examined which mindfulness facets are most strongly associated with Big Five personality domains and facets implicated

  6. 21 CFR 882.4725 - Radiofrequency lesion probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion probe. 882.4725 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4725 Radiofrequency lesion probe. (a) Identification. A radiofrequency lesion probe is a device connected to a radiofrequency (RF...

  7. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  8. The value of SPECT bone scans in diagnosis of patients with zygapophseal joint pain

    International Nuclear Information System (INIS)

    Hu Jiajia; Liang Yu; Li Biao; Zhu Chengmo; Chen Gang; Wang Chao; Tian Weijia; Qu Liumin

    2008-01-01

    Objective: Bone scintigraphy with SPECT of the lumbar spine allows identification of lesions not seen with planar imaging, in patients with chronic low back pain. The aim of this study was to investigate the value of SPECT bone scans in diagnosis of patients with zygapophyseal joint pain. Methods: Thirty-five consecutive patients in Ruijin hospital from July 2006 to March 2007 with low back pain were en- rolled. All patients underwent bone scintigraphy with SPECT. According to the results of SPECT, patients with isotope-uptake joints received injections at the levels where abnormalities were identified on the scan. Patients with negative scans received other treatment (conservative treatment or surgery) but not facet joint injection. Clinical records were collected at 1-, 3-, and 6-month in SPECT-positive group after their initial treatment. And the SPECT-negative group were followed up at 6-month after therapy. Statistical analysis was performed with SPSS 10.0. Patients with SPECT-positive and -negative results were performed with the grouped t-test. Visual analog scales (VAS) were with the paired t-test used in patients with positive scans at before and after treatment. Results: Fifteen cases had facetal uptake of isotope on SPECT bone scans. After facet joint injection, 85.7% patients (12/14, 1 patient was excluded for operation) had improvement in pain score at 1-month, 78.6% (11/14) at 3-month, and 50.0% (7/14) at 6-month. Of 20 negative cases, 3 were treated by surgery and 17 by conservative treatment. All 20 cases were followed up for 6 months and 70.0% (14/20) had long time pain relief. Conclusion: SPECT bone scans are helpful to identify patients with low back pain who would benefit from facet joint injections. (authors)

  9. A folk-psychological ranking of personality facets

    Directory of Open Access Journals (Sweden)

    Eka Roivainen

    2016-10-01

    Full Text Available Background Which personality facets should a general personality test measure? No consensus exists on the facet structure of personality, the nature of facets, or the correct method of identifying the most significant facets. However, it can be hypothesized (the lexical hypothesis that high frequency personality describing words more likely represent important personality facets and rarely used words refer to less significant aspects of personality. Participants and procedure A ranking of personality facets was performed by studying the frequency of the use of popular personality adjectives in causal clauses (because he is a kind person on the Internet and in books as attributes of the word person (kind person. Results In Study 1, the 40 most frequently used adjectives had a cumulative usage frequency equal to that of the rest of the 295 terms studied. When terms with a higher-ranking dictionary synonym or antonym were eliminated, 23 terms remained, which represent 23 different facets. In Study 2, clusters of synonymous terms were examined. Within the top 30 clusters, personality terms were used 855 times compared to 240 for the 70 lower-ranking clusters. Conclusions It is hypothesized that personality facets represented by the top-ranking terms and clusters of terms are important and impactful independent of their correlation with abstract underlying personality factors (five/six factor models. Compared to hierarchical personality models, lists of important facets probably better cover those aspects of personality that are situated between the five or six major domains.

  10. FACET Emittance Growth

    Energy Technology Data Exchange (ETDEWEB)

    Frederico, J; Hogan, M.J.; Nosochkov, Y.; Litos, M.D.; Raubenheimer, T.; /SLAC

    2011-04-05

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to {approx}20 {micro}m long and {approx}10 {micro}m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  11. FACET Emittance Growth

    International Nuclear Information System (INIS)

    Frederico, Joel

    2011-01-01

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The FACET beamline consists of a chicane and final focus system to compress the 23 GeV, 3.2 nC electron bunches to ∼20 (micro)m long and ∼10 (micro)m wide. Simulations of the FACET beamline indicate the short-duration and large, 1.5% rms energy spread beams may suffer a factor of four emittance growth from a combination of chromaticity, incoherent synchrotron radiation (ISR), and coherent synchrotron radiation (CSR). Emittance growth is directly correlated to head erosion in plasma wakefield acceleration and is a limiting factor in single stage performance. Studies of the geometric, CSR, and ISR components are presented. Numerical calculation of the rms emittance can be overwhelmed by long tails in the simulated phase space distributions; more useful definitions of emittance are given. A complete simulation of the beamline is presented as well, which agrees with design specifications.

  12. Clinical Outcome Following Radiofrequency Denervation for Refractory Sacroiliac Joint Dysfunction Using the Simplicity III Probe: A 12-Month Retrospective Evaluation.

    Science.gov (United States)

    Hegarty, Dominic

    2016-01-01

    Sacroiliac joint syndrome (SIJ) is diagnosed in 10% to 25% of cases of lower back pain. The response to traditional radiofrequency (RF) denervation of the SIJ has being inconsistent. The Simplicity III RF probe (Neruotherm. Inc.) offers a novel treatment option. To evaluate the long-term clinical outcome (12 months) refractory SIJ syndrome in terms of pain intensity and functional improvement. A 50% reduction in intensity pain intensity (VAS) at 12 months was deemed clinically significant. A 12-month retrospective observational evaluation all of adults treated with RF for refractory SIJ. Chronic pain management center. The medical records of all adults treated with this technique was retrospectively reviewed. The primary outcome was pain intensity scores (VAS) over a 12 months period; Secondary outcomes included Roland-Morris Functional scores (RMF), Brief Pain Inventory (BPI), general health assessment (Sf12), and patient satisfaction scores (GPI), which were recorded pre and post denervation. Pain Intensity improved by 4.7 points compared to pre-treatment representing a 61% reduction in pain at 12 months (n=11, P < 0.001). Significant improvements in (a) RMF (P < 0.01, W2 = 0.63 (large effect size); (b) BPI (P < 0.001, W2 = 0.72 (strong effect size); and (c) Sf12 (P < 0.01) were noted. Overall patients were satisfied with the outcome (GPI = 77.7%). The retrospective in nature of the study and the small sample size are limitations. As it was our policy to monitor the progress of the individuals since the introduction of this technique a reliable method of recording the baseline and outcome variables at each point of contact was in place. Access to a complete set of variables in all individuals over a 12-month period was therefore possible, which we feel contributes to the quality of the dataset. By creating a consistent radiofrequency lesion between the sacral foramen and the SIJ will reliably capture the innervation to the SIJ with significant long-term clinical

  13. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  14. Predicting nurses' acceptance of radiofrequency identification technology.

    Science.gov (United States)

    Norten, Adam

    2012-10-01

    The technology of radiofrequency identification allows for the scanning of radiofrequency identification-tagged objects and individuals without line-of-sight requirements. Healthcare organizations use radiofrequency identification to ensure the health and safety of patients and medical personnel and to uncover inefficiencies. Although the successful implementation of a system incorporating radiofrequency identification technologies requires acceptance and use of the technology, some nurses using radiofrequency identification in hospitals feel like "Big Brother" is watching them. This predictive study used a theoretical model assessing the effect of five independent variables: privacy concerns, attitudes, subjective norms, controllability, and self-efficacy, on a dependent variable, nurses' behavioral intention to use radiofrequency identification. A Web-based questionnaire containing previously validated questions was answered by 106 US RNs. Multiple linear regression showed that all constructs together accounted for 60% of the variance in nurses' intention to use radiofrequency identification. Of the predictors in the model, attitudes provided the largest unique contribution when the other predictors in the model were held constant; subjective norms also provided a unique contribution. Privacy concerns, controllability, and self-efficacy did not provide a significant contribution to nurses' behavioral intention to use radiofrequency identification.

  15. Conventional Radiofrequency Thermocoagulation vs Pulsed Radiofrequency Neuromodulation of Ganglion Impar in Chronic Perineal Pain of Nononcological Origin.

    Science.gov (United States)

    Usmani, Hammad; Dureja, G P; Andleeb, Roshan; Tauheed, Nazia; Asif, Naiyer

    2018-01-10

    Chronic nononcological perineal pain has been effectively managed by ganglion Impar block. Chemical neurolysis, cryoablation, and radiofrequency ablation have been the accepted methods of blockade. Recently, pulsed radiofrequency, a novel variant of conventional radiofrequency, has been used for this purpose. This was a prospective, randomized, double-blind study. Two different interventional pain management centers in India. To compare the efficacy of conventional radiofrequency and pulsed radiofrequency for gangliom Impar block. The patients were randomly allocated to one of two groups. In the conventional radiofrequency (CRF) group (N = 34), conventional radiofrequency ablation was done, and in the PRF pulsed radiofrequency (PRF) group (N = 31), pulsed radiofrequency ablation was done. After informed and written consent, fluoroscopy-guided ganglion Impar block was performed through the first intracoccygeal approach. The extent of pain relief was assessed by visual analog scale (VAS) at 24 hours, and at the first, third, and sixth weeks following the intervention. A questionnaire to evaluate subjective patient satisfaction was also used at each follow-up visit. In the CRF group, the mean VAS score decreased significantly from the baseline value at each follow-up visit. But in the PRF group, this decrease was insignificant except at 24-hour follow-up. Intergroup comparison also showed significantly better pain relief in the CRF group as compared with the PRF group. At the end of follow-up, 28 patients (82%) in the CRF group and four patients (13%) in the PRF group had excellent results, as assessed by the subjective patient satisfaction questionnaire. There was no complication in any patient of either study group, except for short-lived infection at the site of skin puncture in a few. Ganglion Impar block by conventional radiofrequency provided a significantly better quality of pain relief with no major side effects in patients with chronic

  16. Radiofrequency ablation in dermatology

    Directory of Open Access Journals (Sweden)

    Sachdeva Silonie

    2007-01-01

    Full Text Available Radiofreqeuency ablation is a versatile dermatosurgical procedure used for surgical management of skin lesions by using various forms of alternating current at an ultra high frequency. The major modalities in radiofrequency are electrosection, electrocoagulation, electrodessication and fulguration. The use of radiofrequency ablation in dermatosurgical practice has gained importance in recent years as it can be used to treat most of the skin lesions with ease in less time with clean surgical field due to adequate hemostasis and with minimal side effects and complications. This article focuses on the major tissue effects and factors influencing radiofrequency ablation and its application for various dermatological conditions.

  17. FACET CLASSIFICATIONS OF E-LEARNING TOOLS

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2013-12-01

    Full Text Available The article deals with the classification of e-learning tools based on the facet method, which suggests the separation of the parallel set of objects into independent classification groups; at the same time it is not assumed rigid classification structure and pre-built finite groups classification groups are formed by a combination of values taken from the relevant facets. An attempt to systematize the existing classification of e-learning tools from the standpoint of classification theory is made for the first time. Modern Ukrainian and foreign facet classifications of e-learning tools are described; their positive and negative features compared to classifications based on a hierarchical method are analyzed. The original author's facet classification of e-learning tools is proposed.

  18. CT-guided radiofrequency tumor ablation in children

    International Nuclear Information System (INIS)

    Botsa, Evanthia; Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas; Koutsogiannis, Ioannis; Ziakas, Panayiotis D.; Alexopoulou, Efthimia

    2014-01-01

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  19. CT-guided radiofrequency tumor ablation in children

    Energy Technology Data Exchange (ETDEWEB)

    Botsa, Evanthia [National and Kapodistrian University of Athens, First Pediatric Clinic, Agia Sofia Children' s Hospital, Athens (Greece); Poulou, Loukia S.; Koundouraki, Antonia; Thanos, Loukas [Sotiria General Hospital for Chest Diseases, Department of Medical Imaging and Interventional Radiology, Athens (Greece); Koutsogiannis, Ioannis [General Military Hospital NIMTS, Department of Medical Imaging, Athens (Greece); Ziakas, Panayiotis D. [Warren Alpert Medical School of Brown University Rhode Island Hospital, Division of Infectious Diseases, Providence, RI (United States); Alexopoulou, Efthimia [Attikon University Hospital, Second Department of Radiology, Athens University School of Medicine, Athens (Greece)

    2014-11-15

    Image-guided radiofrequency ablation is a well-accepted technique of interventional oncology in adults. To evaluate the efficacy and safety of CT-guided radiofrequency ablation as a minimally invasive treatment for metastatic neoplasms in children. A total of 15 radiofrequency ablation sessions were performed in 12 children and young adults (median age 9.5; range 5-18 years) with metastatic malignancies. Seven children and young adults had secondary hepatic lesions, three had pulmonary and two had bone lesions. Radiofrequency ablation was performed under conscious sedation. The median lesion size was 1.7 cm (range 1.3-2.8 cm). The median time for ablation was 8 min (range 7-10 min). Radiofrequency procedures were technically successful in all tumors. Postablation imaging immediately after, and 1 month and 3 months after radiofrequency ablation showed total necrosis in all patients. At 6-month follow-up, three patients (all with lesion size >2 cm) had local recurrence and underwent a second radiofrequency ablation session. At 2-year follow-up no patient had recurrence of the treated tumor. Post-ablation syndrome occurred in four children. No major complication occurred. CT-guided radiofrequency tumor ablation was safe and efficient for palliative treatment in our cohort of patients. (orig.)

  20. RADIOFREQUENCY SUPERCONDUCTIVITY: Workshop

    International Nuclear Information System (INIS)

    Lengeler, Herbert

    1989-01-01

    Superconducting radiofrequency is already playing an important role in the beam acceleration system for the TRISTAN electron-positron collider at the Japanese KEK Laboratory and new such systems are being prepared for other major machines. Thus the fourth Workshop on Radiofrequency Superconductivity, organized by KEK under the chairmanship of local specialist Yuzo Kojima and held just before the International Conference on High Energy Accelerators, had much progress to review and even more to look forward to

  1. Antero-medial approach to the wrist: anatomic basis and new application in cases of fracture of the lunate facet.

    Science.gov (United States)

    Uzel, A-P; Bulla, A; Laurent-Joye, M; Caix, P

    2011-08-01

    The Henry approach is the classical anterolateral surgical exposure of the volar aspect of the distal radius. This approach does not allow good access to the medial side of the volar distal radius (lunate facet) and the distal radio-ulnar joint, unless it is extended proximally, retracting the tendons and the median nerve medially, which can cause some trauma. The purpose of our study was to investigate the anatomic basis and to outline the advantages of the unusual anteromedial approach, reporting our experience in the treatment of 4 distal radius fractures, with a 90° or 180° twist of the lunate facet, and 10 wrist dissections on cadavers. The average follow-up was 68.8 months (range 18 to 115 months). In our series, this approach did not cause any nerve injuries or any sensory loss of the distal forearm and the palm. All the fractures of the lunate facet and of the radial styloid process healed. One patient with an ulnar styloid process fracture associated showed pseudarthrosis, but with no instability of the distal radio-ulnar joint or pain on the ulnar side. Using the criteria of Green and O'Brien, modified by Cooney, the results were: excellent in two cases, good in one case, and average in another. The evaluation of arthritis according to Knirk and Jupiter's classification showed grade 0 in three cases and grade 3 in one case with osteochondral sclerosis. We showed that the anteromedial approach is reliable and convenient in the case of fractures situated in the antero-medial portion of the radius, for the double objective of reducing the fracture under direct control and checking the congruence of the distal radio-ulnar joint.

  2. A faceted eye on intellectual giftedness: Examining the personality of gifted students using FFM domains and facets

    Directory of Open Access Journals (Sweden)

    Altaras-Dimitrijević Ana

    2012-01-01

    Full Text Available The study examines the personality profile of gifted vs. average-ability students from the perspective of the FFM. The issue was approached by (1 reviewing the literature for well-established personality characteristics of the gifted, (2 establishing correspondences between these traits and FFM domains/facets, and (3 formulating a domain and a facet-level model which were hypothesized to discriminate significantly between gifted and nongifted students. The domain-level model consisted of Openness and Agreeableness. The facet-level model included 14 traits: Anxiety, Impulsiveness, Gregariousness, Assertiveness, Fantasy, Feelings, Aesthetics, Ideas, Compliance, Modesty, Tendermindedness, Order, Achievement, and Deliberation. The models were tested on three samples (N1=515 high-school students, 155 gifted; N2=132 psychology students, 28 gifted; N3=443 psychology students, 91 gifted. Results indicate that the domain-level model does not discriminate significantly between gifted and nongifted students in each sample, whereas the proposed 14-facet model yields a significant discrimination across all samples. The latter model may be further adjusted by removing facets which proved inconsistent or unsubstantial in distinguishing between the two groups. This yields a 7-facet discriminant function, which is also significant across samples, indicating that gifted students are consistently distinguished by a combination of high Ideas, Fantasy, Aesthetics, and Assertiveness, but low Gregariuosness, Modesty, and Tendermindeness. Educational implications and limitations are discussed. [Projekat Ministarstva nauke Republike Srbije, br. 179018

  3. 21 CFR 882.4400 - Radiofrequency lesion generator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency lesion generator. 882.4400 Section... (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4400 Radiofrequency lesion generator. (a) Identification. A radiofrequency lesion generator is a device used to produce...

  4. Radiofrequency Energy and Electrode Proximity Influences Stereoelectroencephalography-Guided Radiofrequency Thermocoagulation Lesion Size: An In Vitro Study with Clinical Correlation.

    Science.gov (United States)

    Staudt, Michael D; Maturu, Sarita; Miller, Jonathan P

    2018-02-16

    Radiofrequency thermocoagulation of epileptogenic foci via stereoelectroencephalography (SEEG) electrodes has been suggested as a treatment for medically intractable epilepsy, but reported outcomes have been suboptimal, possibly because lesions generated using conventional high-energy radiofrequency parameters are relatively small. To describe a technique of delivering low energy across separate SEEG electrodes in order to create large confluent radiofrequency lesions. The size and configuration of radiofrequency lesions using different radiofrequency intensity and interelectrode distance was assessed in egg whites. Magnetic resonance images (MRI) from 3 patients who had undergone radiofrequency lesion creation were evaluated to determine the contribution of lesion intensity and electrode separation on lesion size. Electroencephalography, MRI, and clinical data were assessed before and after lesion creation. Both in Vitro and in Vivo analysis revealed that less energy paradoxically produced larger lesions, with the largest possible lesions produced when radiofrequency power was applied for long duration at less than 3 W. Linear separation of electrodes also contributed to lesion size, with largest lesions produced when electrodes were separated by a linear distance of between 5 and 12 mm. Clinical lesions produced using these parameters were large and resulted in improvement in interictal and ictal activity. Radiofrequency lesions produced using low-energy delivery between SEEG electrodes in close proximity can produce a large lesion. These findings might have advantages for treatment of focal epilepsy.

  5. Radiofrequency ablation of hepatocellular carcinoma: Mono or multipolar?

    Science.gov (United States)

    Cartier, Victoire; Boursier, Jérôme; Lebigot, Jérôme; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Aubé, Christophe

    2016-03-01

    Thermo-ablation by radiofrequency is recognized as a curative treatment for early-stage hepatocellular carcinoma. However, local recurrence may occur because of incomplete peripheral tumor destruction. Multipolar radiofrequency has been developed to increase the size of the maximal ablation zone. We aimed to compare the efficacy of monopolar and multipolar radiofrequency for the treatment of hepatocellular carcinoma and determine factors predicting failure. A total of 171 consecutive patients with 214 hepatocellular carcinomas were retrospectively included. One hundred fifty-eight tumors were treated with an expandable monopolar electrode and 56 with a multipolar technique using several linear bipolar electrodes. Imaging studies at 6 weeks after treatment, then every 3 months, assessed local effectiveness. Radiofrequency failure was defined as persistent residual tumor after two sessions (primary radiofrequency failure) or local tumor recurrence during follow-up. This study received institutional review board approval (number 2014/77). Imaging showed complete tumor ablation in 207 of 214 lesions after the first session of radiofrequency. After a second session, only two cases of residual viable tumor were observed. During follow-up, there were 46 local tumor recurrences. Thus, radiofrequency failure occurred in 48/214 (22.4%) cases. By multivariate analysis, technique (P radiofrequency failure. Failure rate was lower with the multipolar technique for tumors radiofrequency, multipolar radiofrequency improves tumor ablation with a subsequent lower rate of local tumor recurrence. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  6. The growth of faceted/nonfaceted eutectics

    International Nuclear Information System (INIS)

    Suchtelen, J. van

    1976-01-01

    This paper is concerned with the unidirectional solidification of eutectic melts in which one of the phases has a faceted, the other a nonfaceted solid-liquid interface. The occurrence of complex microstructures in such eutectics is explained as a growth phenomenon. The essential condition for the occurrence of such structures is a non-isothermal solid-liquid interface, developing into a faceted-cellular structure. The faceted shape of the cells is imposed by the faceted component of the eutectic. Breakdown to such a cellular structure occurs not only in constitutional-supercooling conditions, but under any circumstances, the cellular period being a function of growth velocity, temperature gradient etc. The two-phase morphology of the eutectic structure is discussed in terms of the relative magnitude of the periods of the cellular and of the eutectic structure. (orig.) [de

  7. Proposal plan of classification faceted for federal universities

    Directory of Open Access Journals (Sweden)

    Renata Santos Brandão

    2017-09-01

    Full Text Available This study aims to present a faceted classification plan for the archival management of documents in the federal universities of Brazil. For this, was done a literature review on the archival management in Brazil, the types of classification plans and the theory of the Ranganathan faceted classification, through searches in databases in the areas of Librarianship and Archivology. It was identified the classification plan used in the Federal Institutions of Higher Education to represent the functional facet and created the structural classification plan to represent the structural facet. The two classification plans were inserted into a digital repository management system to give rise to the faceted classification plan. The system used was Tainacan, free software wordpress-based used in digital document management. The developed faceted classification plan allows the user to choose and even combine the way to look for the information that guarantees agreater efficiency in the information retrieval.

  8. Pulse-dose radiofrequency treatment in pain management-initial experience.

    Science.gov (United States)

    Ojango, Christine; Raguso, Mario; Fiori, Roberto; Masala, Salvatore

    2018-05-01

    Radiofrequency procedures have been used for treating various chronic pain conditions for decades. These minimally invasive percutaneous treatments employ an alternating electrical current with oscillating radiofrequency wavelengths to eliminate or alter pain signals from the targeted site. The aim of the continuous radiofrequency procedure is to increase the temperature sufficiently to create an irreversible thermal lesion on nerve fibres and thus permanently interrupt pain signals. The pulsed radiofrequency procedure utilises short pulses of radiofrequency current with intervals of longer pauses to avert a temperature increase to the level of permanent tissue damage. The goal of these pulses is to alter the processing of pain signals, but to avoid relevant structural damage to nerve fibres, as seen in the continuous radiofrequency procedure. The pulse-dose radiofrequency procedure is a technical improvement of the pulsed radiofrequency technique in which the delivery mode of the current is adapted. During the pulse-dose radiofrequency procedure thermal damage is avoided. In addition, the amplitude and width of the consecutive pulses are kept the same. The method ensures that each delivered pulse keeps the same characteristics and therefore the dose is similar between patients. The current review outlines the pulse-dose radiofrequency procedure and presents our institution's chronic pain management studies.

  9. Work functions and surface charges at metallic facet edges

    International Nuclear Information System (INIS)

    Fall, C.J.; Binggeli, N.; Baldereschi, A.

    2002-04-01

    The electronic charge densities and work functions at sharp metallic facet edges are determined from ab initio calculations, combined with macroscopic averaging techniques. In particular, we examine how two different work functions coexist at close range near edges between inequivalent facets. The surface ionic relaxation at facet edges is shown to influence appreciably the local electrostatic potential in the vacuum. Various edges between Al(100) and Al(111) facets are studied, as well as between Na(110) facets. We also develop a model of electronic surface dipoles, which accounts for the surface charge transfer between inequivalent facets, and which allows us to predict the influence of the shape and size of a macroscopic crystal on its work functions. (author)

  10. A survey on monopolar radiofrequency treatment.

    Science.gov (United States)

    Suh, Dong Hye; Hong, Eun Sun; Kim, Hyun Joo; Lee, Sang Jun; Kim, Hei Sung

    2017-09-01

    This questionnaire-based study was aimed to measure the level of appreciation, awareness of the special tips, and practice patterns of monopolar radiofrequency among Korean dermatologists practicing a specific monopolar radiofrequency device (Thermage® Inc., Hayward, CA). A total of 82 surveys were analyzed to show that the majority of participants (78.8%) were highly satisfied with the outcomes of monopolar radiofrequency treatment. All respondents were aware of the Eye Tip 0.25 cm 2 , and the majority knew the difference between the Face tip (blue) and the Total tip (orange). Most (86.3%) agreed to the statement that 900 shots were appropriate for facial tightening in those between the ages of 35 and 65 years. 66.2% of participants reported to have perform monopolar radiofrequency to extra-facial sites within the past year. As for the tips, the Total tip was most popular for all body sties and the Big tip was favored for the abdomen, thighs and buttock. We hope our data allow dermatologists to better utilize monopolar radiofrequency. © 2017 Wiley Periodicals, Inc.

  11. Scalable Faceted Ranking in Tagging Systems

    Science.gov (United States)

    Orlicki, José I.; Alvarez-Hamelin, J. Ignacio; Fierens, Pablo I.

    Nowadays, web collaborative tagging systems which allow users to upload, comment on and recommend contents, are growing. Such systems can be represented as graphs where nodes correspond to users and tagged-links to recommendations. In this paper we analyze the problem of computing a ranking of users with respect to a facet described as a set of tags. A straightforward solution is to compute a PageRank-like algorithm on a facet-related graph, but it is not feasible for online computation. We propose an alternative: (i) a ranking for each tag is computed offline on the basis of tag-related subgraphs; (ii) a faceted order is generated online by merging rankings corresponding to all the tags in the facet. Based on the graph analysis of YouTube and Flickr, we show that step (i) is scalable. We also present efficient algorithms for step (ii), which are evaluated by comparing their results with two gold standards.

  12. Management of pain on hallux valgus with percutaneous intra-articular Pulse-Dose Radiofrequency.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Calabria, Eros; Raguso, Mario; de Vivo, Dominique; Cuzzolino, Alessandro; Simonetti, Giovanni

    2017-01-01

    The purpose of our study was to investigate the role of intra-articular pulse-dose radiofrequency in management of painful hallux valgus refractory to conservative therapies. Between November 2010 and April 2012, 51 patients (15 male, 36 female) with a median age of 71.4 years were included in our clinical trial. Under fluoroscopic guidance we introduced a 22 gauge 10 cm length cannula by a percutaneous access in the first metatarsophalangeal joint and its tip was placed intra-articularly. After removing the spindle, a radiofrequency needle with a 5 mm active tip was introduced. The following parameters were used: 1200 pulses at high voltage (45 V) with 20 msec duration followed by 480 msec silent phases. A great reduction in pain intensity was documented at 1 week, 1 month and 3 months after procedures. Pain intensity increased between 5 and 8 months after treatments, so we performed a second procedure in all patients between 7 months and 9 months since the first treatment. Also in this case we obtained a great reduction of pain intensity in the first 3 months after the procedure. Pain intensity returned at preprocedural values after 9 months after second procedure. No complications were observed. Our experience shows pulse-dose radiofrequency is a safe, repeatable and effective technique for managing patients with symptomatic hallux valgus in the short and medium term. Pulse-dose radiofrequency may improve pain control and quality of life in patients with hallux valgus refractory to conservative therapies. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  13. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  14. SLAC Linac Preparations for FACET

    International Nuclear Information System (INIS)

    Erickson, Roger

    2011-01-01

    The SLAC 3km linear electron accelerator has been cut at the two-thirds point to provide beams to two independent programs. The last third provides the electron beam for the Linac Coherent Light Source (LCLS), leaving the first two-thirds available for FACET, the new experimental facility for accelerator science and test beams. In this paper, we describe this separation and projects to prepare the linac for the FACET experimental program.

  15. Framework Application for Core Edge Transport Simulation (FACETS)

    Energy Technology Data Exchange (ETDEWEB)

    Malony, Allen D; Shende, Sameer S; Huck, Kevin A; Mr. Alan Morris, and Mr. Wyatt Spear

    2012-03-14

    The goal of the FACETS project (Framework Application for Core-Edge Transport Simulations) was to provide a multiphysics, parallel framework application (FACETS) that will enable whole-device modeling for the U.S. fusion program, to provide the modeling infrastructure needed for ITER, the next step fusion confinement device. Through use of modern computational methods, including component technology and object oriented design, FACETS is able to switch from one model to another for a given aspect of the physics in a flexible manner. This enables use of simplified models for rapid turnaround or high-fidelity models that can take advantage of the largest supercomputer hardware. FACETS does so in a heterogeneous parallel context, where different parts of the application execute in parallel by utilizing task farming, domain decomposition, and/or pipelining as needed and applicable. ParaTools, Inc. was tasked with supporting the performance analysis and tuning of the FACETS components and framework in order to achieve the parallel scaling goals of the project. The TAU Performance System® was used for instrumentation, measurement, archiving, and profile / tracing analysis. ParaTools, Inc. also assisted in FACETS performance engineering efforts. Through the use of the TAU Performance System, ParaTools provided instrumentation, measurement, analysis and archival support for the FACETS project. Performance optimization of key components has yielded significant performance speedups. TAU was integrated into the FACETS build for both the full coupled application and the UEDGE component. The performance database provided archival storage of the performance regression testing data generated by the project, and helped to track improvements in the software development.

  16. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  17. Radiofrequency Ablation of Hepatic Cysts : Case Report

    International Nuclear Information System (INIS)

    Lee, Ye Ri; Kim, Pyo Nyun

    2005-01-01

    Radiofrequency ablation has been frequently performed on intra-hepatic solid tumor, namely, hepatocellular carcinoma, metastatic tumor and cholangio carcinoma, for take the cure. But, the reports of radiofrequency ablation for intrahepatic simple cysts are few. In vitro experiment of animal and in vivo treatment for intrahepatic cysts of human had been reported in rare cases. We report 4 cases of radiofrequency ablation for symptomatic intrahepatic cysts

  18. Ablation of liver metastases by radiofrequency

    International Nuclear Information System (INIS)

    Baere, T. de

    2012-01-01

    Radiofrequency is a thermal ablative technique that is most often used percuteanously under image guidance. Thermal damage is obtained through frictional heating of a high frequency current. The maximal volume of destruction obtained in one radiofrequency delivery is around 4 cm and consequently, best indication for treatment are tumours below 3 cm. When compared, radiofrequency and surgical removal for tumours below 25 mm in diameter demonstrated a rate of incomplete resection/ablation of 6% and 7.3% respectively. Median survival after the first radiofrequency of a liver metastasis of CRC is reported to be 24 to 52 months with a 5 years overall survival of 18 to 44%. The median overall survival increases from 22 to 48 months depending on the use of radiofrequency ablation as rescue treatment after failure of others, or as a first line treatment. For patients with a single tumour, less than 4 cm, the survival rates at 1, 3, and 5 years are respectively 97%, 84% and 40%, with a median survival of 50 months. Follow-up imaging requires to use contrast-enhanced CT or MRI, looking for local recurrences evidenced by local foci of enhancement at the periphery of the ablation zone. (author)

  19. 47 CFR 1.1310 - Radiofrequency radiation exposure limits.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency radiation exposure limits. 1... Procedures Implementing the National Environmental Policy Act of 1969 § 1.1310 Radiofrequency radiation... exposure to radiofrequency (RF) radiation as specified in § 1.1307(b), except in the case of portable...

  20. Pulsed radiofrequency of the composite nerve supply to the knee joint as a new technique for relieving osteoarthritic pain: a preliminary report.

    Science.gov (United States)

    Vas, Lakshmi; Pai, Renuka; Khandagale, Nishigandha; Pattnaik, Manorama

    2014-01-01

    We report a new technique for pulsed radiofrequency (PRF) of the entire nerve supply of the knee as an option in treating osteoarthritis (OA) of knee. We targeted both sensory and motor nerves supplying all the structures around the knee: joint, muscles, and skin to address the entire nociception and stiffness leading to peripheral and central sensitization in osteoarthritis. Ten patients with pain, stiffness, and loss of function in both knees were treated with ultrasonography (USG) guided PRF of saphenous, tibial, and common peroneal nerves along with subsartorial, peripatellar, and popliteal plexuses. USG guided PRF of the femoral nerve was also done to address the innervation of the quadriceps muscle. Assessment of pain (Numerical Rating Scale [NRS], pain DETECT, knee function [Western Ontario and McMaster Universities Osteoarthritis Index- WOMAC]) were documented pre and post PRF at 3 and 6 months. Knee radiographs (Kellgren-Lawrence [K-L] grading) were done before PRF and one week later. All the patients showed a sustained improvement of NRS, pain DETECT, and WOMAC at 3 and 6 months. The significant improvement of patellar position and tibio-femoral joint space was concordant with the patient's reporting of improvement in stiffness and pain. The sustained pain relief and muscle relaxation enabled the patients to optimize physiotherapy thereby improving endurance training to include the daily activities of life. We conclude that OA knee pain is a product of neuromyopathy and that PRF of the sensory and motor nerves appeared to be a safe, effective, and minimally invasive technique. The reduction of pain and stiffness improved the knee function and probably reduced the peripheral and central sensitization.

  1. Preamble to marine microbiology: Facets and opportunities

    Digital Repository Service at National Institute of Oceanography (India)

    Ramaiah, N.

    The book titled 'Marine Microbiology: Facets & Opportunities' is an attempt to bring together some facets of marine microbiology as have been made out by many contemporaries in particular from the tropical marine regions. There are 18 contributed...

  2. Migration mechanisms of a faceted grain boundary

    Science.gov (United States)

    Hadian, R.; Grabowski, B.; Finnis, M. W.; Neugebauer, J.

    2018-04-01

    We report molecular dynamics simulations and their analysis for a mixed tilt and twist grain boundary vicinal to the Σ 7 symmetric tilt boundary of the type {1 2 3 } in aluminum. When minimized in energy at 0 K , a grain boundary of this type exhibits nanofacets that contain kinks. We observe that at higher temperatures of migration simulations, given extended annealing times, it is energetically favorable for these nanofacets to coalesce into a large terrace-facet structure. Therefore, we initiate the simulations from such a structure and study as a function of applied driving force and temperature how the boundary migrates. We find the migration of a faceted boundary can be described in terms of the flow of steps. The migration is dominated at lower driving force by the collective motion of the steps incorporated in the facet, and at higher driving forces by the step detachment from the terrace-facet junction and propagation of steps across the terraces. The velocity of steps on terraces is faster than their velocity when incorporated in the facet, and very much faster than the velocity of the facet profile itself, which is almost stationary. A simple kinetic Monte Carlo model matches the broad kinematic features revealed by the molecular dynamics. Since the mechanisms seem likely to be very general on kinked grain-boundary planes, the step-flow description is a promising approach to more quantitative modeling of general grain boundaries.

  3. Cervical endplate and facet arthrosis: an anatomic study of cadaveric specimens.

    Science.gov (United States)

    Master, Daniel L; Toy, Jason O; Eubanks, Jason D; Ahn, Nicholas U

    2012-10-01

    An anatomic, epidemiologic study of cervical endplate and facet arthrosis in cadaveric spines. To determine the prevalence of cervical endplate and facet arthrosis and the relationship between these 2 entities in a large population sample. Cervical endplate and facet arthrosis are common radiographic findings, which have both been linked to pain. However, the prevalence and relationship between cervical endplate and facet arthrosis has not been clearly defined. The cervical vertebrae from 234 cadaveric spines were examined by a single investigator for evidence of endplate and facet arthrosis. Arthrosis at each endplate and facet was graded on a continuum from 0 to IV. Race, age at death, and sex of each specimen were also recorded. Stepwise multiple linear regression was used to analyze any association between race, age, sex, endplate arthrosis, and facet arthrosis. Factors with P values arthrosis severity scores among patients within the same decades of life. Concurrent cervical endplate and facet arthrosis was present in 77% of the study population. Stepwise multiple linear regression revealed significant (Parthrosis and between age and facet arthrosis. Race and sex did not correlate with facet arthrosis. In addition, patients in age groups 30 to 39, 40 to 49, 50 to 59, 60 to 69, 70 to 79, and 80 to 89 demonstrated more severe (Parthrosis in comparison with facet arthrosis. Concurrent cervical endplate and facet arthrosis is a common condition. Cervical endplate arthrosis and advancing age are associated with cervical facet arthrosis independent of race and sex. Cervical endplate arthrosis precedes facet arthrosis.

  4. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1997-08-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed.

  5. Saline-enhanced radiofrequency electrocoagulation in bovine liver

    International Nuclear Information System (INIS)

    Shin, Hong Seop; Oh, Joo Hyeong; Yoon, Yup; Kim, Hyun Cheol; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won; Kim, Eui Jong

    1997-01-01

    To determine the effectiveness of saline-enhanced radiofrequency electrocoagulation in bovine liver tissue Saline-enhanced radiofrequency electrocoagulation (group I), hot saline injection induced by radiofrequency electrocoagulation (group II), and radiofrequency electrocoagulation (group III) were performed in ex vivo bovine liver. Radiofrequency power was 100 and 200 watts, and current was applied for 10, 20, and 30 seconds. Tissue was histopathologically examined for thermal injury. The largest diameter of thermal injury was about 41.0 mm in group I, 12.3 mm in group II and 9.3 mm in group III. The mean diameter of the injury increased with higher wattage in group I and II and with longer procedure time in group I (p<0.05). At corresponding wattage and times, group I showed a larger diameter of thermal injury and more increase in than group II or III (p<0.05). The degree of carbonization was more severe in group III than in groups I and II. Grossly, thermal injury showed a well-defined, relatively spherical configuration without extension along parenchymal interstitium. In an animal model, saline-enhanced radiofrequency electrocoagulation may effectively induce thermal injury, and may thus be another effective tool for use in the treatment of hepatic tumors. Further clinical experience is needed

  6. Analysis of movement axes of the ankle and subtalar joints: relationship with the articular surfaces of the talus.

    Science.gov (United States)

    Cho, Ho-Jung; Kwak, Dai-Soon; Kim, In-Beom

    2014-10-01

    Bone shape varies among human populations, and in the case of articular joints, the shape of the articulating surfaces strongly influences joint movement. In this study, we aimed to analyse the axes of the talocrural and subtalar joints, using the talar articular surface method, and compare these results with those of the previous studies. We used three-dimensional reconstruction models of tali among Korean individuals. The axes of the talocrural and subtalar joints were calculated by using the least-square sphere fitting method, and the principal axis was used for reference coordination. The shape of the talus was classified based on the shape of its anterior, middle, and posterior calcaneal facets, and the talar shape was compared with the movement axes. The movement axes did not differ according to the type of calcaneal facets of the talus. Interestingly, we also noted that the axes of the talocrural and subtalar joints in this study differed significantly from those reported in the previous studies; these differences may be due to variations in the shape of the bones. © IMechE 2014.

  7. Image-guided radiofrequency ablation of renal cell carcinoma

    International Nuclear Information System (INIS)

    Boss, Andreas; Clasen, Stephan; Pereira, Philippe L.; Kuczyk, Markus; Schick, Fritz

    2007-01-01

    The incidence of renal cell carcinoma is rising with the increased number of incidental detection of small tumours. During the past few years, percutaneous imaging-guided radiofrequency ablation has evolved as a minimally invasive treatment of small unresectable renal tumours offering reduced patient morbidity and overall health care costs. In radiofrequency ablation, thermal energy is deposited into a targeted tumour by means of a radiofrequency applicator. In recent studies, radiofrequency ablation was shown to be an effective and safe modality for local destruction of renal cell carcinoma. Radiofrequency applicator navigation can be performed via ultrasound, computed tomography or magnetic resonance guidance; however, ultrasound seems less favourable because of the absence of monitoring capabilities during ablation. On-line monitoring of treatment outcome can only be performed with magnetic resonance imaging giving the possibility of eventual applicator repositioning to ablate visible residual tumour tissue. Long-term follow-up is crucial to assess completeness of tumour ablation. New developments in ablation technology and radiological equipment will further increase the indication field for radiofrequency ablation of renal cell carcinoma. Altogether, radiofrequency ablation seems to be a promising new modality for the minimally invasive treatment of renal cell carcinoma, which was demonstrated to exhibit high short-term effectiveness. (orig.)

  8. New-generation radiofrequency technology.

    Science.gov (United States)

    Krueger, Nils; Sadick, Neil S

    2013-01-01

    Radiofrequency (RF) technology has become a standard treatment in aesthetic medicine with many indications due to its versatility, efficacy, and safety. It is used worldwide for cellulite reduction; acne scar revision; and treatment of hypertrophic scars and keloids, rosacea, and inflammatory acne in all skin types. However, the most common indication for RF technology is the nonablative tightening of tissue to improve skin laxity and reduce wrinkles. Radiofrequency devices are classified as unipolar, bipolar, or multipolar depending on the number of electrodes used. Additional modalities include fractional RF; sublative RF; phase-controlled RF; and combination RF therapies that apply light, massage, or pulsed electromagnetic fields (PEMFs). This article reviews studies and case series on these devices. Radiofrequency technology for aesthetic medicine has seen rapid advancements since it was used for skin tightening in 2003. Future developments will continue to keep RF technology at the forefront of the dermatologist's armamentarium for skin tightening and rejuvenation.

  9. Concurrent, parallel, multiphysics coupling in the FACETS project

    Energy Technology Data Exchange (ETDEWEB)

    Cary, J R; Carlsson, J A; Hakim, A H; Kruger, S E; Miah, M; Pletzer, A; Shasharina, S [Tech-X Corporation, 5621 Arapahoe Avenue, Suite A, Boulder, CO 80303 (United States); Candy, J; Groebner, R J [General Atomics (United States); Cobb, J; Fahey, M R [Oak Ridge National Laboratory (United States); Cohen, R H; Epperly, T [Lawrence Livermore National Laboratory (United States); Estep, D J [Colorado State University (United States); Krasheninnikov, S [University of California at San Diego (United States); Malony, A D [ParaTools, Inc (United States); McCune, D C [Princeton Plasma Physics Laboratory (United States); McInnes, L; Balay, S [Argonne National Laboratory (United States); Pankin, A, E-mail: cary@txcorp.co [Lehigh University (United States)

    2009-07-01

    FACETS (Framework Application for Core-Edge Transport Simulations), is now in its third year. The FACETS team has developed a framework for concurrent coupling of parallel computational physics for use on Leadership Class Facilities (LCFs). In the course of the last year, FACETS has tackled many of the difficult problems of moving to parallel, integrated modeling by developing algorithms for coupled systems, extracting legacy applications as components, modifying them to run on LCFs, and improving the performance of all components. The development of FACETS abides by rigorous engineering standards, including cross platform build and test systems, with the latter covering regression, performance, and visualization. In addition, FACETS has demonstrated the ability to incorporate full turbulence computations for the highest fidelity transport computations. Early indications are that the framework, using such computations, scales to multiple tens of thousands of processors. These accomplishments were a result of an interdisciplinary collaboration among computational physics, computer scientists and applied mathematicians on the team.

  10. Clinical trial involving sufferers and non-sufferers of cervicogenic headache (CGH): potential mechanisms of action of photobiomodulation (Conference Presentation)

    Science.gov (United States)

    Liebert, Ann D.; Bicknell, Brian

    2017-02-01

    Photobiomodulation (PBM) is an effective tool for the management of spinal pain including inflammation of facet joints. Apart from cervical and lumbar joint pain the upper cervical spine facet joint inflammation can result in the CGH (traumatic or atraumatic in origin). This condition affects children, adults and elders and is responsible for 19% of chronic headache and up to 33% of patients in pain clinics. The condition responds well to physiotherapy, facet joint injection, radiofrequency neurotomy and surgery at a rate of 75%. The other 25% being unresponsive to treatment with no identified features of unresponsiveness. In other conditions of chronic unresponsive cervical pain have responded to photobiomodulation at a level of 80% in the short and medium term. A clinical trial was therefore conducted on a cohort of atraumatic patients from the ages of 5-93 (predominantly Neurologist referred / familial sufferers 2/3 generations vertically and laterally) who had responded to a course of PBM and physiotherapy. The CGH sufferers and their non CGH suffering relatives over these generations were then compared for features that distinguish the two groups. Fifty parameters were tested (anthropmetric, movement and neural tension tests included) and there was a noted difference in tandem stance between the groups (.04 significance with repeated measures). As this impairment is common to benign ataxia and migrainous vertigo and in these conditions there is an ion channelopathy (especially potassium channelopathy). A postulated mechanism of action of PBM would involve modulation of ion channels and this is discussed in this presentation.

  11. Cervical facet oedema: prevalence, correlation to symptoms, and follow-up imaging

    International Nuclear Information System (INIS)

    Nevalainen, M.T.; Foran, P.J.; Roedl, J.B.; Zoga, A.C.; Morrison, W.B.

    2016-01-01

    Aim: To evaluate the prevalence of cervical facet oedema in patients referred for magnetic resonance imaging (MRI) to investigate neck pain and/or radiculopathy, and to investigate whether there is a correlation between the presence of oedema and patients' symptoms. Materials and methods: A retrospective report review of 1885 patients undergoing cervical spine MRI between July 2008 and June 2015 was performed. Exclusion criteria included acute trauma, surgery, neoplastic disease, or infection in the cervical spine. One hundred and seventy-three MRI studies with cervical facet oedema were evaluated by each of the two radiologists. In these patients, the grade of bone marrow oedema (BMO) and corresponding neuroforaminal narrowing at the cervical facets was assessed. Correlation with symptoms was performed based on pre-MRI questionnaire. Results: The prevalence of cervical facet oedema was 9%; the most commonly affected levels were C3–4, C4–5, and C2–3. A total of 202 cervical facets were evaluated: mild BMO was seen in 35%, moderate in 41%, and severe in 24% of cases. Surrounding soft-tissue oedema was observed in 36%, 69%, and 92% of the BMO grades, respectively. The correlations between unilateral radiculopathy and ipsilateral facet BMO grades were 79%, 83%, and 73% (chi-square, p<0.001), respectively. Furthermore, neuroforaminal narrowing on the corresponding level was found in 35%, 38%, and 11% of cases, respectively. At follow-up imaging, facet oedema was most likely to remain unchanged or to decrease. Conclusion: The prevalence of cervical facet oedema is 9%. Cervical facet oedema is associated with ipsilateral radiculopathy. Neuroforaminal narrowing, however, is not associated with facet oedema. - Highlights: • Association between the cervical facet oedema and cervical radiculopathy was studied. • Prevalence of the cervical facet oedema was 9%. • Facet oedema was associated with radiculopathy regardless of the degree of oedema. • Neuroforaminal

  12. Eight Key Facets of Small Business Management.

    Science.gov (United States)

    Scott, James Calvert

    1980-01-01

    Identifies eight key facets of small business management and suggests activities that may be used to assist in their development. The key facets are (1) product or service, (2) competition, (3) marketing strategies, (4) personnel needs, (5) equipment and facility needs, (6) finances, (7) planning, and (8) entrepreneurship. (JOW)

  13. Future ATM Concepts Evaluation Tool (FACET) Interface Control Document

    Science.gov (United States)

    Grabbe, Shon R.

    2017-01-01

    This Interface Control Document (ICD) documents the airspace adaptation and air traffic inputs of NASA's Future ATM Concepts and Evaluation Tool (FACET). Its intended audience is the project manager, project team, development team, and stakeholders interested in interfacing with the system. FACET equips Air Traffic Management (ATM) researchers and service providers with a way to explore, develop and evaluate advanced air transportation concepts before they are field-tested and eventually deployed. FACET is a flexible software tool that is capable of quickly generating and analyzing thousands of aircraft trajectories. It provides researchers with a simulation environment for preliminary testing of advanced ATM concepts. Using aircraft performance profiles, airspace models, weather data, and flight schedules, the tool models trajectories for the climb, cruise, and descent phases of flight for each type of aircraft. An advanced graphical interface displays traffic patterns in two and three dimensions, under various current and projected conditions for specific airspace regions or over the entire continental United States. The system is able to simulate a full day's dynamic national airspace system (NAS) operations, model system uncertainty, measure the impact of different decision-makers in the NAS, and provide analysis of the results in graphical form, including sector, airport, fix, and airway usage statistics. NASA researchers test and analyze the system-wide impact of new traffic flow management algorithms under anticipated air traffic growth projections on the nation's air traffic system. In addition to modeling the airspace system for NASA research, FACET has also successfully transitioned into a valuable tool for operational use. Federal Aviation Administration (FAA) traffic flow managers and commercial airline dispatchers have used FACET technology for real-time operations planning. FACET integrates live air traffic data from FAA radar systems and weather data

  14. Lumbar facet anatomy changes in spondylolysis: a comparative skeletal study

    Science.gov (United States)

    Dar, Gali; Peleg, Smadar; Steinberg, Nili; Alperovitch-Najenson, Dvora; Salame, Khalil; Hershkovitz, Israel

    2007-01-01

    Opinions differ as to the exact mechanism responsible for spondylolysis (SP) and whether individuals with specific morphological characteristics of the lumbar vertebral neural arch are predisposed to SP. The aim of our study was to reveal the association between SP and the architecture of lumbar articular facets and the inter-facet region. Methods: Using a Microscribe three-dimensional apparatus (Immersion Co., San Jose, CA, USA), length, width and depth of all articular facets and all inter-facet distances in the lumbar spine (L1–L5) were measured. From the Hamann-Todd Human Osteological Collection (Cleveland Museum of Natural History, OH, USA) 120 normal male skeletons with lumbar spines in the control group and 115 with bilateral SP at L5 were selected. Analysis of variance was employed to examine the differences between spondylolytic and normal spines. Results: Three profound differences between SP and the norm appeared: (1) in individuals with SP, the size and shape of L4’s neural arch had significantly greater inter-facet widths, significantly shorter inter-facet heights and significantly shorter and narrower articular facets; (2) only in the L4 vertebra in individuals with SP was the inferior inter-facet width greater in size than the superior inter-facet width of the vertebra below (L5) (38.7 mm versus 40 mm); (3) in all lumbar vertebrae, the right inferior articular facets in individuals with SP were flatter compared to the control group. Conclusions: Individuals with L4 “SP” characteristics are at a greater risk of developing fatigue fractures in the form of spondylolysis at L5. PMID:17440753

  15. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  16. Acromioclavicular joint separation

    Directory of Open Access Journals (Sweden)

    Devan Pandya, BS

    2018-04-01

    Full Text Available History of present illness: A 30-year-old male was brought in by ambulance to the emergency department as a trauma activation after a motorcycle accident. The patient was the helmeted rider of a motorcycle traveling at an unknown speed when he lost control and was thrown off his vehicle. He denied loss of consciousness, nausea, or vomiting. The patient’s vital signs were stable and his only complaint was pain around his left shoulder. On exam, the patient had a prominent left clavicle without skin compromise. He had adequate range of motion in the left shoulder with moderate pain, and his left upper extremity was neurovascularly intact. Significant findings: Plain films of the left shoulder showed elevation of the left clavicle above the acromion. There was an increase in the acromioclavicular (AC and coracoclavicular (CC distances (increased joint distances marked with red and blue arrows, respectively. A normal AC joint measures 1-3 mm whereas a normal CC distance measures 11-13 mm.1 The injury was classified as a Rockwood type III AC joint separation. Discussion: The AC joint is a synovial joint between an oval facet on the acromion and a similar facet on the distal end of the clavicle. Horizontal stability is provided by the AC joint while axial stability is provided by the CC joint.2,3 AC joint injuries account for about 9%-12% of shoulder girdle injuries, and the most common mechanism is direct trauma.4,5 Initial evaluation with imaging includes plain films with three views: the anterior-posterior (AP view with the shoulder in internal and external rotation as well as an axillary, or scapula-Y view (sensitivity 40%, specificity 90% for all films.6,7 AC joint injuries are classified by the Rockwood system.8 Type I involves a sprain or incomplete tear of the AC ligaments with an intact CC ligament. The AC joint appears normal on X-ray, but can become widened with stress, achieved by having the patient hold a 10-15 pound weight from each

  17. Radiofrequency initiation and radiofrequency sustainment of laser initiated seeded high pressure plasma

    International Nuclear Information System (INIS)

    Paller, Eric S.; Scharer, John E.; Akhtar, Kamran; Kelly, Kurt; Ding, Guowen

    2001-01-01

    We examine radiofrequency initiation of high pressure(1-70 Torr) inductive plasma discharges in argon, nitrogen, air and organic seed gas mixtures. Millimeter wave interferometry, optical emission and antenna wave impedance measurements for double half-turn helix and helical inductive antennas are used to interpret the rf/plasma coupling, measure the densities in the range of 10 12 cm -3 and analyze the ionization and excited states of the gas mixtures. We have also carried out 193 nm excimer laser initiation of an organic gas seed plasma which is sustained at higher pressures(150 Torr) by radiofrequency coupling at 2.8 kW power levels

  18. Arthroscopic guided biopsy and radiofrequency thermoablation of a benign neoplasm of the tibial spines area: a treatment option

    Directory of Open Access Journals (Sweden)

    Zoccali Carmine

    2012-04-01

    Full Text Available Abstract Background Lesions located in the area of the tibial spines are rare. In most cases, treatment follows histological diagnosis, but when imaging and clinical data are considered to be "very" characteristic for benign lesions, such as chondroblastoma or osteoid osteoma, treatment may be performed without biopsy. Traditional curettage requires opening the joint, which presents a high risk of contamination of the joint itself and surrounding structures, such as the popliteal area, with possible contamination of the neurovascular bundle when performing curettage with the posterior approach. In this case, the re-excision of a local recurrence would be extremely difficult. Results We describe a technique using arthroscopic guidance for radiofrequency thermoablation of a benign lesion in the tibial spines area. We report on an illustrative case. The patient so treated, reported immediate relief from the pain, and after two weeks, was free of pain. The biopsy performed before the treatment confirmed the radiological diagnosis of chondroblastoma. At one year of follow-up, the patient is without pain, with a 0-130°range of motion, has no activity limitations and is apparently free of disease. Conclusion This technique allows a radiofrequency thermoablation of a lesion in the tibial spines area and in the posterior tibial surface to be performed without opening the joint, monitoring the tibial plateau surface, probably decreasing the risk of cartilage damage. Unfortunately, in the case presented, the high pressure from the arthroscopy's pump broke the tibial plateau surface creating a communication to the tibial tunnel used for thermoablation.

  19. Subtalar joint stress imaging with tomosynthesis.

    Science.gov (United States)

    Teramoto, Atsushi; Watanabe, Kota; Takashima, Hiroyuki; Yamashita, Toshihiko

    2014-06-01

    The purpose of this study was to perform stress imaging of hindfoot inversion and eversion using tomosynthesis and to assess the subtalar joint range of motion (ROM) of healthy subjects. The subjects were 15 healthy volunteers with a mean age of 29.1 years. Coronal tomosynthesis stress imaging of the subtalar joint was performed in a total of 30 left and right ankles. A Telos stress device was used for the stress load, and the load was 150 N for both inversion and eversion. Tomographic images in which the posterior talocalcaneal joint could be confirmed on the neutral position images were used in measurements. The angle of the intersection formed by a line through the lateral articular facet of the posterior talocalcaneal joint and a line through the surface of the trochlea of the talus was measured. The mean change in the angle of the calcaneus with respect to the talus was 10.3 ± 4.8° with inversion stress and 5.0 ± 3.8° with eversion stress from the neutral position. The result was a clearer depiction of the subtalar joint, and inversion and eversion ROM of the subtalar joint was shown to be about 15° in healthy subjects. Diagnostic, Level IV.

  20. Hyperkalaemia after radiofrequency ablation of hepatocellular carcinoma

    NARCIS (Netherlands)

    Verhoevena, BH; Haagsma, EB; Appeltans, BMG; Slooff, MJH; de Jong, KP

    Radiofrequency ablation of liver tumours is a useful therapy for otherwise unresectable tumours. The complication rate is said to be low. In this case report we describe hyperkalaemia after radiofrequency ablation of a hepatocellular carcinoma in a patient with end-stage renal insufficiency. (C)

  1. Radio-frequency integrated-circuit engineering

    CERN Document Server

    Nguyen, Cam

    2015-01-01

    Radio-Frequency Integrated-Circuit Engineering addresses the theory, analysis and design of passive and active RFIC's using Si-based CMOS and Bi-CMOS technologies, and other non-silicon based technologies. The materials covered are self-contained and presented in such detail that allows readers with only undergraduate electrical engineering knowledge in EM, RF, and circuits to understand and design RFICs. Organized into sixteen chapters, blending analog and microwave engineering, Radio-Frequency Integrated-Circuit Engineering emphasizes the microwave engineering approach for RFICs. Provide

  2. Radiofrequency catheter oblation in atrial flutter

    International Nuclear Information System (INIS)

    Yan Ji; Wang Heping; Xu Jian; Liu Fuyuan; Fan Xizhen; An Chunsheng; Han Xiaoping; Ding Xiaomei; Wang Jiasheng; Gu Tongyuan

    2002-01-01

    Objective: To evaluate the radiofrequency catheter ablation for type I atrial flutter through application of Holo catheter labelling with anatomic imaging localization to ablate the isthmus of IVCTA during complete double-way block. Methods: Eleven cases with type I atrial flutter undergone Holo catheter labelling technique and consecution with conduction time change of coronary venous sinus orifice with-right atrial lower lateral wall pace excitation, were performed with radiofrequency catheter ablation for the isthmus outcoming with complete double-way conduction block. Results: All together 11 cases with 4 of atrial flutter and 7 of sinus rhythm were undergone radiofrequency catheter ablation resulting with double-way conduction block of the isthmus accompanied by prolongation of right atrial conduction time 56.0 ± 2.3 ms and 53.0 ± 4.6 ms respectively. The right atrial excitation appeared to be in clockwise and counter-clockwise of single direction. No recurrence occurred during 3-34 months follow up with only one showing atrial fibrillation. Conclusions: The application of Holo catheter labelling technique with anatomic imaging localization to achieve the double-way conduction block by radiofrequency catheter ablation of TVC-TA isthmus, is a reliable method for treating atrial flutter

  3. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  4. 21 CFR 870.2910 - Radiofrequency physiological signal transmitter and receiver.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency physiological signal transmitter... Devices § 870.2910 Radiofrequency physiological signal transmitter and receiver. (a) Identification. A radiofrequency physiological signal transmitter and receiver is a device used to condition a physiological signal...

  5. Effect of Calcaneus Fracture Gap Without Step-Off on Stress Distribution Across the Subtalar Joint.

    Science.gov (United States)

    Barrick, Brett; Joyce, Donald A; Werner, Frederick W; Iannolo, Maria

    2017-03-01

    Subtalar arthritis is a common consequence following calcaneal fracture, and its development is related to the severity of the fracture. Previous calcaneal fracture models have demonstrated altered contact characteristics when a step-off is created in the posterior facet articular surface. Changes in posterior facet contact characteristics have not been previously characterized for calcaneal fracture gap without step-off. The contact characteristics (peak pressure, area of contact, and centroid of pressure) of the posterior facet of the subtalar joint were determined in 6 cadaveric specimens. After creating a calcaneal fracture to simulate a Sanders type II fracture, the contact characteristics were determined with the posterior facet anatomically reduced followed by an incremental increase in fracture gap displacement of 2, 3, and 5 mm without a step-off of the articular surface. Peak pressure on the medial fragment was significantly less with a 5-mm gap compared to a 2- or 3-mm gap, or reduced. On the lateral fragment, the peak pressure was significantly increased with a 5-mm gap compared to a 2- or 3-mm gap. Contact area significantly changed with increased gap. In this study, there were no significant differences in contact characteristics between a <3-mm gap and an anatomically reduced fracture, conceding the study limitations including limiting axial loading to 50% of donor body weight. A small amount of articular incongruity without a step-off can be tolerated by the subtalar joint, in contrast to articular incongruity with a step-off present.

  6. Large conservation gains possible for global biodiversity facets

    Science.gov (United States)

    Pollock, Laura J.; Thuiller, Wilfried; Jetz, Walter

    2017-06-01

    Different facets of biodiversity other than species numbers are increasingly appreciated as critical for maintaining the function of ecosystems and their services to humans. While new international policy and assessment processes such as the Intergovernmental Science-Policy Platform on Biodiversity and Ecosystem Services (IPBES) recognize the importance of an increasingly global, quantitative and comprehensive approach to biodiversity protection, most insights are still focused on a single facet of biodiversity—species. Here we broaden the focus and provide an evaluation of how much of the world’s species, functional and phylogenetic diversity of birds and mammals is currently protected and the scope for improvement. We show that the large existing gaps in the coverage for each facet of diversity could be remedied by a slight expansion of protected areas: an additional 5% of the land has the potential to more than triple the protected range of species or phylogenetic or functional units. Further, the same areas are often priorities for multiple diversity facets and for both taxa. However, we find that the choice of conservation strategy has a fundamental effect on outcomes. It is more difficult (that is, requires more land) to maximize basic representation of the global biodiversity pool than to maximize local diversity. Overall, species and phylogenetic priorities are more similar to each other than they are to functional priorities, and priorities for the different bird biodiversity facets are more similar than those of mammals. Our work shows that large gains in biodiversity protection are possible, while also highlighting the need to explicitly link desired conservation objectives and biodiversity metrics. We provide a framework and quantitative tools to advance these goals for multi-faceted biodiversity conservation.

  7. Large conservation gains possible for global biodiversity facets.

    Science.gov (United States)

    Pollock, Laura J; Thuiller, Wilfried; Jetz, Walter

    2017-06-01

    Different facets of biodiversity other than species numbers are increasingly appreciated as critical for maintaining the function of ecosystems and their services to humans. While new international policy and assessment processes such as the Intergovernmental Science-Policy Platform on Biodiversity and Ecosystem Services (IPBES) recognize the importance of an increasingly global, quantitative and comprehensive approach to biodiversity protection, most insights are still focused on a single facet of biodiversity-species. Here we broaden the focus and provide an evaluation of how much of the world's species, functional and phylogenetic diversity of birds and mammals is currently protected and the scope for improvement. We show that the large existing gaps in the coverage for each facet of diversity could be remedied by a slight expansion of protected areas: an additional 5% of the land has the potential to more than triple the protected range of species or phylogenetic or functional units. Further, the same areas are often priorities for multiple diversity facets and for both taxa. However, we find that the choice of conservation strategy has a fundamental effect on outcomes. It is more difficult (that is, requires more land) to maximize basic representation of the global biodiversity pool than to maximize local diversity. Overall, species and phylogenetic priorities are more similar to each other than they are to functional priorities, and priorities for the different bird biodiversity facets are more similar than those of mammals. Our work shows that large gains in biodiversity protection are possible, while also highlighting the need to explicitly link desired conservation objectives and biodiversity metrics. We provide a framework and quantitative tools to advance these goals for multi-faceted biodiversity conservation.

  8. Correlation between lumbar lordosis and the treatment of chronic low back pain with pulsed radiofrequency applied to the L2 dorsal root ganglion

    Directory of Open Access Journals (Sweden)

    Hsien-Ta Hsu

    2017-01-01

    Conclusion: PRF applied to the L2 DRG is an alternative procedure for treating patients with chronic low back pain, regardless of which type of LL the patients have. Chronic low back pain, including discogenic pain and facet joint pain, may be treated by PRF applied to the L2 DRG.

  9. About a possibility of increasing the adhesion strength between mineral glass and polymeric binder under radio-frequency induction plasma treatment

    International Nuclear Information System (INIS)

    Miftakhov, I S; Trofimov, A V; Nagmutdinova, A I; Voznesensky, E F; Sharifullin, F S; Krasina, I V; Rakhmatullina, G R

    2017-01-01

    The paper investigated influences of radio-frequency induction plasma treatment on the surface of sheet mineral glasses for household purpose. Discussion for casting the most suitable treatment modes and theirs substantiation is shown. During the investigation the most productive plasma treatment modes for applied binders have been found. It is shown that the durability of adhesive joints between mineral glass and polymeric binder under low-temperature plasma treatment increase to 65%. (paper)

  10. Radiofrequency-thermoablation in malignant liver disease

    International Nuclear Information System (INIS)

    Pichler, L.; Anzboeck, W.; Paertan, G.; Hruby, W.

    2002-01-01

    The clinical application of radiofrequency tumor ablation in primary liver tumors and metastatic liver disease is rapidly growing because this technique has proven to be simple, safe, and effective in first clinical studies. Most of the patients with malignant liver disease are not candidates for surgical resection due localisation or comorbidity, so radiofrequency therapy offers a good alternative for inoperable patients. With this method, high frequency alternating current is delivered to tissue via a needle electrode, the produced heat leads to coagulation necrosis. The largest focus of necrosis that can be induced with the currently available systems is approximately 4-5 cm with a single application. The radiofrequency needle is usually placed with US or CT guidance. For follow up examinations CT and MRI can be used, they proved to be equally accurate in the assessment of treatment response. (orig.) [de

  11. Fractionated bipolar radiofrequency and bipolar radiofrequency potentiated by infrared light for treating striae: A prospective randomized, comparative trial with objective evaluation.

    Science.gov (United States)

    Harmelin, Yona; Boineau, Dominique; Cardot-Leccia, Nathalie; Fontas, Eric; Bahadoran, Philippe; Becker, Anne-Lise; Montaudié, Henri; Castela, Emeline; Perrin, Christophe; Lacour, Jean-Philippe; Passeron, Thierry

    2016-03-01

    Very few treatments for striae are based on prospective randomized trials. The objective of this study was to assess the efficacy of bipolar fractional radiofrequency and bipolar radiofrequency potentiated with infrared light, alone or combined, for treating abdominal stretch marks. Bicentric prospective interventional randomized controlled trial in the department of Dermatology of University Hospital of Nice and Aesthetics Laser Center of Bordeaux, France. Men and women of age 18 years or above, who presented for the treatment of mature or immature abdominal striae were included. The patients' abdomens were divided into four equal quadrants. Bipolar radiofrequency potentiated with infrared light and fractional bipolar radiofrequency were applied, alone or combined, and compared to the remaining untreated quadrant. The main criterion of evaluation was the measurement of depth of striae, using 3D photography at 6 months follow-up. A global assessment was also rated by the physician performing the treatment and by the patients. Histological analysis and confocal laser microscopy were additionally performed. A total of 22 patients were enrolled, and 384 striae were measured. In per protocol analysis mean striae depth was decreased by 21.64%, observed at 6 months follow-up with the combined approach, compared to an increase of 1.73% in the control group (P radiofrequency, combined with bipolar radiofrequency potentiated by infrared light, is an effective treatment of both immature and mature striae of the abdomen. © 2016 Wiley Periodicals, Inc.

  12. Temperature-controlled radiofrequency ablation of cardiac tissue

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1999-01-01

    BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequ......BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available...... for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips......-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors...

  13. Pulsed Radiofrequency Ablation for Treating Sural Neuralgia.

    Science.gov (United States)

    Abd-Elsayed, Alaa; Jackson, Markus; Plovanich, Elizabeth

    2018-01-01

    Sural neuralgia is persistent pain in the distribution of the sural nerve that provides sensation to the lateral posterior corner of the leg, lateral foot, and fifth toe. Sural neuralgia is a rare condition but can be challenging to treat and can cause significant limitation. We present 2 cases of sural neuralgia resistant to conservative management that were effectively treated by pulsed radiofrequency ablation. A 65-year-old female developed sural neuralgia after a foot surgery and failed conservative management. She had successful sural nerve blocks, and pulsed radiofrequency ablation led to an 80% improvement in her pain. A 33-year-old female presented with sural neuralgia secondary to two falls. The patient had tried several conservative modalities with no success. We performed diagnostic blocks and pulsed radiofrequency ablation, and the patient reported 80% improvement in her pain. Pulsed radiofrequency ablation may be a safe and effective treatment for patients with sural neuralgia that does not respond to conservative therapy. However, studies are needed to elucidate its effectiveness and safety profile.

  14. Impact of Project Leadership Facets on Project Outcome

    Directory of Open Access Journals (Sweden)

    Arslan Ayub

    2015-08-01

    Full Text Available The study analyzes the role of project leadership facets on effective project outcome. Numerous such initiatives have already been taken on project outcome/performance in the context of apposite leadership styles or project management. However, the current study is unique in the milieu of project outcome that it introduces a new leadership approach, which throws light on the significance of variant leadership facets on project outcome. The study uses explanatory approach; primary data is collected from project management professionals working in different project organizations. The study uses structural equation model (SEM technique to test the hypothesis. The study found a positive relationship between project leadership facets and project outcome.

  15. The radiofrequency frontier: a review of radiofrequency and combined radiofrequency pulsed-light technology in aesthetic medicine.

    Science.gov (United States)

    Sadick, Neil; Sorhaindo, Lian

    2005-05-01

    Radiofrequency (RF) and combined RF light source technologies have established themselves as safe and effective treatment modalities for several dermatologic procedures, including skin tightening, hair and leg vein removal, acne scarring, skin rejuvenation, and wrinkle reduction. This article reviews the technology, clinical applications, and recent advances of RF and combined RF light/laser source technologies in aesthetic medicine.

  16. Treatment of acne vulgaris with fractional radiofrequency microneedling.

    Science.gov (United States)

    Kim, Sang Tae; Lee, Kang Hoon; Sim, Hyung Jun; Suh, Kee Suck; Jang, Min Soo

    2014-07-01

    Fractional radiofrequency microneedling is a novel radiofrequency technique that uses insulated microneedles to deliver energy to the deep dermis at the point of penetration without destruction of the epidermis. It has been used for the treatment of various dermatological conditions including wrinkles, atrophic scars and hypertrophic scars. There have been few studies evaluating the efficacy of fractional radiofrequency microneedling in the treatment of acne, and none measuring objective parameters like the number of inflammatory and non-inflammatory acne lesions or sebum excretion levels. The safety and efficacy of fractional radiofrequency microneedling in the treatment of acne vulgaris was investigated. In a prospective clinical trial, 25 patients with moderate to severe acne were treated with fractional radiofrequency microneedling. The procedure was carried out three times at 1-month intervals. Acne lesion count, subjective satisfaction score, sebum excretion level and adverse effects were assessed at baseline and at 4, 8 and 12 weeks after the first treatment as well as 4, 8 and 12 weeks after the last treatment. Number of acne lesions (inflammatory and non-inflammatory) decreased. Sebum excretion and subjective satisfaction were more favorable at every time point compared with the baseline values (P acne vulgaris. © 2014 Japanese Dermatological Association.

  17. Crack Front Segmentation and Facet Coarsening in Mixed-Mode Fracture

    Science.gov (United States)

    Chen, Chih-Hung; Cambonie, Tristan; Lazarus, Veronique; Nicoli, Matteo; Pons, Antonio J.; Karma, Alain

    2015-12-01

    A planar crack generically segments into an array of "daughter cracks" shaped as tilted facets when loaded with both a tensile stress normal to the crack plane (mode I) and a shear stress parallel to the crack front (mode III). We investigate facet propagation and coarsening using in situ microscopy observations of fracture surfaces at different stages of quasistatic mixed-mode crack propagation and phase-field simulations. The results demonstrate that the bifurcation from propagating a planar to segmented crack front is strongly subcritical, reconciling previous theoretical predictions of linear stability analysis with experimental observations. They further show that facet coarsening is a self-similar process driven by a spatial period-doubling instability of facet arrays.

  18. Domains and facets: hierarchical personality assessment using the revised NEO personality inventory.

    Science.gov (United States)

    Costa, P T; McCrae, R R

    1995-02-01

    Personality traits are organized hierarchically, with narrow, specific traits combining to define broad, global factors. The Revised NEO Personality Inventory (NEO-PI-R; Costa & McCrae, 1992c) assesses personality at both levels, with six specific facet scales in each of five broad domains. This article describes conceptual issues in specifying facets of a domain and reports evidence on the validity of NEO-PI-R facet scales. Facet analysis-the interpretation of a scale in terms of the specific facets with which it correlates-is illustrated using alternative measures of the five-factor model and occupational scales. Finally, the hierarchical interpretation of personality profiles is discussed. Interpretation on the domain level yields a rapid understanding of the individual interpretation of specific facet scales gives a more detailed assessment.

  19. Tests of beam-based alignement at FACET

    CERN Document Server

    Latina, A; Schulte, D; Adli, E

    2014-01-01

    The performance of future linear colliders will depend critically on beam-based alignment (BBA) and feedback systems, which will play a crucial role in guaranteeing the low emittance transport throughout such machines. BBA algorithms designed to improve the beam transmission in a linac by simultaneously optimising the trajectory and minimising the residual dispersion, have thoughtfully been studied in theory over the last years, and successfully verified experimentally. One such technique is called Dispersion-Free Steering (DFS). A careful study of the DFS performance at the SLAC test facility FACET lead us to design a beam-based technique specifically targeted to reduce the impact of transverse short-range wakefields, rather than of the dispersion, being the wakefields the limiting factor to the FACET performance. This technique is called Wakefield-Free Steering (WFS). The results of the first tests of WFS at FACET are presented in this paper.

  20. Improving personality facet scores with multidimensional computer adaptive testing

    DEFF Research Database (Denmark)

    Makransky, Guido; Mortensen, Erik Lykke; Glas, Cees A W

    2013-01-01

    personality tests contain many highly correlated facets. This article investigates the possibility of increasing the precision of the NEO PI-R facet scores by scoring items with multidimensional item response theory and by efficiently administering and scoring items with multidimensional computer adaptive...

  1. Radiofrequency amplifier based on a DC superconducting quantum interference device

    International Nuclear Information System (INIS)

    Martinis, J.M.; Hilbert, C.; Clarke, J.

    1986-01-01

    A method is described of amplifying a radiofrequency signal consisting of: disposing a single symmetrically biased dc SQUID and an input coil within a superconducting shield, the dc SQUID having a superconducting ring interrupted by two shunted Josephson junctions, and the input coil being inductively coupled solely to the ring of the single SQUID, establishing a constant magnetic flux threading the SQUID ring, applying the radiofrequency signal to the input coil from outside of the superconducting shield, obtaining an amplified radiofrequency signal solely from across the ring of the single SQUID, transmitting the amplified radiofrequency signal from across the SQUID ring to the outside of the superconducting shield

  2. Metallic implants and exposure to radiofrequency radiation

    International Nuclear Information System (INIS)

    Joyner, K.H.; Fleming, A.H.F.; MacFarlane, I.P.; Hocking, B.

    1988-01-01

    There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches 1 . The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in Telecom Australia, beginning with the general principles and then presenting a specific example discussion of a specific example

  3. New resonant circuits for the ISOLTRAP radiofrequency quadrupole trap

    CERN Document Server

    SENECAL, Pierre

    2015-01-01

    This report describes my work during my Summer Student Program. My main project was building and testing a resonance-circuit box for a radio-frequency power supply used with the radio-frequency cooler and buncher.

  4. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications.

    Science.gov (United States)

    Trinidad, José Manuel; Carnota, Ana Isabel; Failde, Inmaculada; Torres, Luis Miguel

    2015-01-01

    Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%). The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied). We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  5. Radiofrequency for the Treatment of Lumbar Radicular Pain: Impact on Surgical Indications

    Directory of Open Access Journals (Sweden)

    José Manuel Trinidad

    2015-01-01

    Full Text Available Study Design. Quasiexperimental study. Objective. To investigate whether radiofrequency treatment can preclude the need for spinal surgery in both the short term and long term. Background. Radiofrequency is commonly used to treat lumbosacral radicular pain. Only few studies have evaluated its effects on surgical indications. Methods. We conducted a quasiexperimental study of 43 patients who had been scheduled for spinal surgery. Radiofrequency was indicated for 25 patients. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment (pulsed radiofrequency of dorsal root ganglion, 76%; conventional radiofrequency of the medial branch, 12%; combined technique, 12%. The primary endpoint was the decision of the patient to reject spinal surgery 1 month and 1 year after treatment. In addition, we also evaluated adverse effects, ODI, NRS. Results. We observed after treatment with radiofrequency 80% of patients rejected spinal surgery in the short term and 76% in the long term. We conclude that radiofrequency is a useful treatment strategy that can achieve very similar outcomes to spinal surgery. Patients also reported a very high level of satisfaction (84% satisfied/very satisfied. We also found that optimization of the electrical parameters of the radiofrequency improved the outcome of this technique.

  6. Symplicity multi-electrode radiofrequency renal denervation system feasibility study.

    Science.gov (United States)

    Whitbourn, Robert; Harding, Scott A; Walton, Antony

    2015-05-01

    The aim of this study was to test the safety and performance of the Symplicity™ multi-electrode radio-frequency renal denervation system which was designed to reduce procedure time during renal denervation. The multi-electrode radiofrequency renal denervation system feasibility study is a prospective, non-randomised, open label, feasibility study that enrolled 50 subjects with hypertension. The study utilises a new renal denervation catheter which contains an array of four electrodes mounted in a helical configuration at 90 degrees from each other to deliver radiofrequency energy simultaneously to all four renal artery quadrants for 60 seconds. The protocol specified one renal denervation treatment towards the distal end of each main renal artery with radiofrequency energy delivered for 60 seconds per treatment. Total treatment time for both renal arteries was two minutes. The 12-month change in office systolic blood pressure (SBP) and 24-hour SBP was -19.2±25.2 mmHg, prenal artery stenosis or hypertensive emergencies occurred. The Symplicity multi-electrode radiofrequency renal denervation system was associated with a significant reduction in SBP at 12 months and minimal complications whilst it also reduced procedure time. NCT01699529.

  7. The Structure of Spatial Ability Items: A Faceted Analysis.

    Science.gov (United States)

    Guttman, Ruth; Shoham, Ilana

    1982-01-01

    Eight spatial tests assembled with a mapping sentence of four content facets (rule type, dimensionality, presence or absence of rotation, and test format) were administered to 800 individuals. Smallest Space Analysis of an intercorrelation matrix yielded three facets which formed distinct regions in a two-dimensional projection of a…

  8. Faceted MoS2 nanotubes and nanoflowers

    International Nuclear Information System (INIS)

    Deepak, Francis Leonard; Mayoral, Alvaro; Yacaman, Miguel Jose

    2009-01-01

    A simple synthesis of novel faceted MoS 2 nanotubes (NTs) and nanoflowers (NFs) starting from molybdenum oxide and thiourea as the sulphur source is reported. The MoS 2 nanotubes with the faceted morphology have not been observed before. Further the as-synthesized MoS 2 nanotubes have high internal surface area. The nanostructures have been characterized by a variety of electron microscopy techniques. It is expected that these MoS 2 nanostrutures will find important applications in energy storage, catalysis and field emission.

  9. Treatment of Benign Thyroid Nodules: Comparison of Surgery with Radiofrequency Ablation.

    Science.gov (United States)

    Che, Y; Jin, S; Shi, C; Wang, L; Zhang, X; Li, Y; Baek, J H

    2015-07-01

    Nodular goiter is one of the most common benign lesions in thyroid nodule. The main treatment of the disease is still the traditional surgical resection, however there are many problems such as general anesthesia, surgical scar, postoperative thyroid or parathyroid function abnormalities, and high nodules recurrence rate in residual gland. The purpose of this study was to compare the efficacy, safety, and cost-effectiveness of 2 treatment methods, surgery and radiofrequency ablation, for the treatment of benign thyroid nodules. From May 2012 to September 2013, 200 patients with nodular goiters who underwent surgery (group A) and 200 patients treated by radiofrequency ablation (group B) were enrolled in this study. Inclusion criteria were the following: 1) cosmetic problem, 2) nodule-related symptoms, 3) hyperfunctioning nodules related to thyrotoxicosis, and 4) refusal of surgery (for group B). An internally cooled radiofrequency ablation system and an 18-ga internally cooled electrode were used. We compared the 2 groups in terms of efficacy, safety, and cost-effectiveness during a 1-year follow-up. After radiofrequency ablation, the nodule volume decreased significantly from 5.4 to 0.4 mL (P = .002) at the 12-month follow-up. The incidence of complications was significantly higher from surgery than from radiofrequency ablation (6.0% versus 1.0%, P = .002). Hypothyroidism was detected in 71.5% of patients after surgery but in none following radiofrequency ablation. The rate of residual nodules (11.9% versus 2.9%, P = .004) and hospitalization days was significantly greater after surgery (6.6 versus 2.1 days, P radiofrequency ablation are both effective treatments of nodular goiter. Compared with surgery, the advantages of radiofrequency ablation include fewer complications, preservation of thyroid function, and fewer hospitalization days. Therefore, radiofrequency ablation should be considered a first-line treatment for benign thyroid nodules. © 2015 by American

  10. Long-Term Developmental Changes in Children's Lower-Order Big Five Personality Facets.

    Science.gov (United States)

    de Haan, Amaranta; De Pauw, Sarah; van den Akker, Alithe; Deković, Maja; Prinzie, Peter

    2017-10-01

    This study examined long-term developmental changes in mother-rated lower-order facets of children's Big Five dimensions. Two independent community samples covering early childhood (2-4.5 years; N = 365, 39% girls) and middle childhood to the end of middle adolescence (6-17 years; N = 579, 50% girls) were used. All children had the Belgian nationality. Developmental changes were examined using cohort-sequential latent growth modeling on the 18 facets of the Hierarchical Personality Inventory for Children. In early childhood, changes were mostly similar across child gender. Between 2 and 4.5 years, several facets showed mean-level stability; others changed in the direction of less Extraversion and Emotional Stability, and more Benevolence and Imagination. The lower-order facets of Conscientiousness showed opposite changes. Gender differences became more apparent from middle childhood onward for facets of all dimensions except Imagination, for which no gender differences were found. Between 6 and 17 years, same-dimension facets showed different shapes of growth. Facets that changed linearly changed mostly in the direction of less Extraversion, Benevolence, Conscientiousness, Emotional Stability, and Imagination. Changes in facets for which nonlinear growth was found generally moved in direction or magnitude during developmental transitions. This study provides comprehensive, fine-grained knowledge about personality development during the first two decades of life. © 2016 Wiley Periodicals, Inc.

  11. Specific oriented metal-organic framework membranes and their facet-tuned separation performance.

    Science.gov (United States)

    Mao, Yiyin; Su, Binbin; Cao, Wei; Li, Junwei; Ying, Yulong; Ying, Wen; Hou, Yajun; Sun, Luwei; Peng, Xinsheng

    2014-09-24

    Modulating the crystal morphology, or the exposed crystal facets, of metal-organic frameworks (MOFs) expands their potential applications in catalysis, adsorption, and separation. In this article, by immobilizing the citrate modulators on Au nanoparticles and subsequently being fixed on solid copper hydroxide nanostrands, a well-intergrown and oriented HKUST-1 cube crystal membrane was formed at room temperature. In contrast, in the absence of Au nanoparticles, well-intergrown and oriented cuboctahedron and octahedron membranes were formed in water/ethanol and ethanol, respectively. The gas separation performances of these HKUST-1 membranes were tuned via their exposed facets with defined pore sizes. The HKUST-1 cube membrane with exposed {001} facets demonstrated the highest permeance but lowest gas binary separation factors, while the octahedron membrane with exposed {111} facets presented the highest separation factors but lowest permeance, since the window size of {111} facets is 0.46 nm which is smaller than 0.9 nm of {001} facets. Separation of 0.38 nm CO2 from 0.55 nm SF6 was realized by the HKUST-1 octahedron membrane. As a proof of concept, this will open a new way to design MOF-related separation membranes by facet controlling.

  12. Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency, Bipolar Radiofrequency, and Microwave, Using Ex Vivo Calf Liver Model

    Science.gov (United States)

    Pillai, Krishna; Akhter, Javid; Chua, Terence C.; Shehata, Mena; Alzahrani, Nayef; Al-Alem, Issan; Morris, David L.

    2015-01-01

    Abstract Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices. With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored. With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres. Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected. Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5. MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink. PMID:25738477

  13. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  14. The prevalence cervical facet arthrosis: an osseous study in a cadveric population.

    Science.gov (United States)

    Lee, Michael J; Riew, K Daniel

    2009-09-01

    Cervical facet arthrosis has been implicated as a cause for neck pain, radiculopathy, occipital headache, and ear pain. The objective of this study was to examine the occurrence of facet arthrosis in the cervical spine. This study examined cadaveric specimens from the Hamann Todd Collection. None. None. Four hundred sixty-five skeletally mature human cervical spines from the Hamann Todd Collection in the Cleveland Museum of Natural History were obtained for analysis. We analyzed the facets for arthrosis. We graded no arthrosis as Grade 0. Facets with peripheral osteophytic reaction, but with no lateral mass distortion were graded as Grade 1. Facets with peripheral osteophytic reaction and lateral mass distortion were graded as Grade 2. Facets that were ankylosed were graded as Grade 3. Each specimen was examined bilaterally at levels from C2-C3 through C6-C7, yielding 4,650 specimen assessments. The data were analyzed to compare cervical levels, gender, facet side, age groups, and race. Proportion analysis, using the Fisher exact test, was used to assess for statistical difference between various groupings. In the entire population of 465 specimens, the upper cervical specimens appeared to be affected by facet arthrosis more frequently than the lower levels; 12.37% of the specimens had bony evidence of arthrosis at the C2-C3 level; 13.33% of the specimens had arthrosis occur at the C3-C4 level; 14.62% at the C4-C5 level; 7.85% at the C5-C6 level, and 4.84% at the C6-C7 level. The large majority of all cervical facet arthrosis was found to be Grade 1 at all levels. In the older population, the prevalence of facet arthrosis is as high as 29.87% for the C4-C5 level. C4-C5 level appears to be affected the most frequently, followed by the C3-C4 level, then C2-C3, C5-C6, and C6-C7. The prevalence of cervical facet arthrosis increases with age, and occurs more commonly in the upper cervical spine.

  15. Radiofrequency ablation of liver tumors (II): clinical application and outcomes.

    Science.gov (United States)

    Vanagas, Tomas; Gulbinas, Antanas; Pundzius, Juozas; Barauskas, Giedrius

    2010-01-01

    Radiofrequency ablation is one of the alternatives in the management of liver tumors, especially in patients who are not candidates for surgery. The aim of this article is to review applicability of radiofrequency ablation achieving complete tumor destruction, utility of imaging techniques for patients' follow-up, indications for local ablative procedures, procedure-associated morbidity and mortality, and long-term results in patients with different tumors. The success of local thermal ablation consists in creating adequate volumes of tissue destruction with adequate "clear margin," depending on improved delivery of radiofrequency energy and modulated tissue biophysiology. Different volumes of coagulation necrosis are achieved applying different types of electrodes, pulsing energy sources, utilizing sophisticated ablation schemes. Some additional methods are used to increase the overall deposition of energy through alterations in tissue electrical conductivity, to improve heat retention within the tissue, and to modulate tolerance of tumor tissue to hyperthermia. Contrast-enhanced computed tomography, magnetic resonance imaging, ultrasound or positron emission tomography are applied to control the effectiveness of radiofrequency ablation. The long-term results of radiofrequency ablation are controversial.

  16. The usability issues of faceted navigation in digital libraries

    Directory of Open Access Journals (Sweden)

    Eliane Blumer

    2014-05-01

    For more than five years, the project ACCEPT, a subproject of a Swiss national project called e-lib.ch, analyzes the usability and usefulness of digital libraries, by using user oriented methods. Experience has shown that filters provided through faceted navigation are considered as positive and very useful by end users. Nevertheless, based on different test results, several returning mistakes have been detected and it turns out that there are some ‘unwritten standards’ concerning e.g. position, labelling or ranking which should be respected to fulfil the aim of a good usability which users do expect of such web services. In this poster we will first give an introduction to faceted navigation, actual design issues and their use in digital libraries and then present testing methods, which can be easily applied in a digital library context. Together with a list of best practices concerning faceted navigation drawn out of different test experiences, the paper should give the reader all important information to evaluate its current faceted navigation and see where improvements could be made.

  17. 77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment

    Science.gov (United States)

    2012-07-25

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 2 [FCC 12-60] Grantee Codes for Certified Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... authorization program for radiofrequency (RF) devices under part 2 of its rules. This program is one of the...

  18. Clinical application and developmental trend of radiofrequency ablation technology

    International Nuclear Information System (INIS)

    Chen Dongfeng

    2009-01-01

    For recent two decades, radiofrequency ablation technology has made great progress in the field of the treatment for neoplasm. At the very beginning, radiofrequency ablation was adopted in treating the hepatic carcinoma, and since then it has been gradually practiced in treating malignancies of lung, bone, kidney, breast, prostate and other solid tumors. Statistical report of the year 2008 has indicated that in the aspect of similar therapeutic measures radiofrequency ablation therapy for tumors holds a 9% market share. Moreover, in the coming years the clinical use of this kind of therapy for tumors will be steadily increasing by 13% every year. (authors)

  19. Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.

    Science.gov (United States)

    Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn

    2011-06-01

    The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, Pradiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.

  20. Facility for Advanced Accelerator Experimental Tests at SLAC (FACET) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.; Bane, K.; /SLAC

    2009-10-30

    This Conceptual Design Report (CDR) describes the design of FACET. It will be updated to stay current with the developing design of the facility. This CDR begins as the baseline conceptual design and will evolve into an 'as-built' manual for the completed facility. The Executive Summary, Chapter 1, gives an introduction to the FACET project and describes the salient features of its design. Chapter 2 gives an overview of FACET. It describes the general parameters of the machine and the basic approaches to implementation. The FACET project does not include the implementation of specific scientific experiments either for plasma wake-field acceleration for other applications. Nonetheless, enough work has been done to define potential experiments to assure that the facility can meet the requirements of the experimental community. Chapter 3, Scientific Case, describes the planned plasma wakefield and other experiments. Chapter 4, Technical Description of FACET, describes the parameters and design of all technical systems of FACET. FACET uses the first two thirds of the existing SLAC linac to accelerate the beam to about 20GeV, and compress it with the aid of two chicanes, located in Sector 10 and Sector 20. The Sector 20 area will include a focusing system, the generic experimental area and the beam dump. Chapter 5, Management of Scientific Program, describes the management of the scientific program at FACET. Chapter 6, Environment, Safety and Health and Quality Assurance, describes the existing programs at SLAC and their application to the FACET project. It includes a preliminary analysis of safety hazards and the planned mitigation. Chapter 7, Work Breakdown Structure, describes the structure used for developing the cost estimates, which will also be used to manage the project. The chapter defines the scope of work of each element down to level 3.

  1. Facility for Advanced Accelerator Experimental Tests at SLAC (FACET) Conceptual Design Report

    International Nuclear Information System (INIS)

    Amann, J.; Bane, K.

    2009-01-01

    This Conceptual Design Report (CDR) describes the design of FACET. It will be updated to stay current with the developing design of the facility. This CDR begins as the baseline conceptual design and will evolve into an 'as-built' manual for the completed facility. The Executive Summary, Chapter 1, gives an introduction to the FACET project and describes the salient features of its design. Chapter 2 gives an overview of FACET. It describes the general parameters of the machine and the basic approaches to implementation. The FACET project does not include the implementation of specific scientific experiments either for plasma wake-field acceleration for other applications. Nonetheless, enough work has been done to define potential experiments to assure that the facility can meet the requirements of the experimental community. Chapter 3, Scientific Case, describes the planned plasma wakefield and other experiments. Chapter 4, Technical Description of FACET, describes the parameters and design of all technical systems of FACET. FACET uses the first two thirds of the existing SLAC linac to accelerate the beam to about 20GeV, and compress it with the aid of two chicanes, located in Sector 10 and Sector 20. The Sector 20 area will include a focusing system, the generic experimental area and the beam dump. Chapter 5, Management of Scientific Program, describes the management of the scientific program at FACET. Chapter 6, Environment, Safety and Health and Quality Assurance, describes the existing programs at SLAC and their application to the FACET project. It includes a preliminary analysis of safety hazards and the planned mitigation. Chapter 7, Work Breakdown Structure, describes the structure used for developing the cost estimates, which will also be used to manage the project. The chapter defines the scope of work of each element down to level 3.

  2. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  3. Technical Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-08-26

    Electrons can “surf” on waves of plasma – a hot gas of charged particles – gaining very high energies in very short distances. This approach, called plasma wakefield acceleration, has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider has been the focus of FACET, a National User Facility at SLAC. FACET used part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and their antimatter counterparts, positrons. Research into plasma wakefield acceleration was the primary motivation for constructing FACET. In April 2016, FACET operations came to an end to make way for the second phase of SLAC’s x-ray laser, the LCLS-II, which will use part of the tunnel occupied by FACET. FACET-II is a new test facility to provide the unique capability to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. FACET-II represents a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique.

  4. Radiofrequency ablation of osteoid osteomas: five years experience.

    Science.gov (United States)

    Papathanassiou, Zafiria G; Petsas, Theodore; Papachristou, Dionysios; Megas, Panagiotis

    2011-12-01

    The purpose of this study is to retrospectively evaluate the efficacy of radiofrequency ablation as a curative treatment method for benign bone tumours. Twenty-nine osteoid osteomas were treated with radiofrequency ablation. Primary success rate was 89.6% and total secondary success rate was 93.1%. Mean clinical follow-up period was 26.7 months (range: 6-63 months). Statistical analysis of 25 cases of osteoid osteomas with CT follow-up revealed that post-treatment re-ossification does not correlate with clinical outcome (p = 0.14) but is strongly correlated with long-term (> or = 12 months) CT follow-up (p = 0.014). Percutaneous radiofrequency ablation was found to be an effective and safe treatment for osteoid osteomas. CT findings cannot solely differentiate between treatment successes and failures.

  5. Extraversion and psychopathology: A facet-level analysis.

    Science.gov (United States)

    Watson, David; Stasik, Sara M; Ellickson-Larew, Stephanie; Stanton, Kasey

    2015-05-01

    The goal of this study was to explicate how the lower order facets of extraversion are related to psychopathology. We used a "bottom-up" approach in which specific extraversion scales from 3 comprehensive personality inventories were used to model these facets as latent factors. We collected both self-report and interview measures of a broad range of psychopathology from a large community sample. Replicating previous findings using a similar approach (Naragon-Gainey & Watson, 2014; Naragon-Gainey, Watson, & Markon, 2009), structural analyses yielded four factors: Positive Emotionality, Sociability, Assertiveness, and Experience Seeking. Scores on these latent dimensions were related to psychopathology in correlational analyses and in two sets of regressions (the first series used the four facets as predictors; the second included composite scores on the other Big Five domains as additional predictors). These results revealed a striking level of specificity. As predicted, Positive Emotionality displayed especially strong negative links to depressive symptoms and diagnoses. Sociability also was negatively related to psychopathology, showing particularly strong associations with indicators of social dysfunction and the negative symptoms of schizotypy (i.e., social anxiety, social aloofness, and restricted affectivity). Assertiveness generally had weak associations at the bivariate level but was negatively related to social anxiety and was positively correlated with some forms of externalizing. Finally, Experience Seeking had substantial positive associations with a broad range of indicators related to externalizing and bipolar disorder; it also displayed negative links to agoraphobia. These differential correlates demonstrate the importance of examining personality-psychopathology relations at the specific facet level. (c) 2015 APA, all rights reserved).

  6. Interactions between radiofrequency signals and living organisms

    International Nuclear Information System (INIS)

    Boudin, F.; Hours, M.; Lacronique, J.F.; Conil, E.; Hadjem, A.; El Habachi, A.; Wiart, K.; Mann, S.; Kundi, M.; Marc-Vergnes, J.P.; Roosli, M.; Mohler, E.; Frei, P.; Davis, Ch.C.; Balzano, Q.; Ait-Aissa, S.; Billaudel, B.; Poulletier De Gannes, F.; Hurtier, A.; Haro, E.; Taxile, M.; Veyret, B.; Lagroye, I.; Ait-Aissa, S.; Poulletier De Gannes, F.; Athane, A.; Veyret, B.; Lagroye, I.; Yardin, C.; Perrin, A.; Freire, M.; Bachelet, Ch.; Collin, A.; Pla, S.; Debouzy, J.C.; Leveque, Ph.; Van Nierop, L.E.; Huss, A.; Roosli, M.; Egger, M.; Calvez, M.; Salomon, D.

    2010-01-01

    This dossier is composed of 13 articles dealing with the interactions between radio-frequencies and living organisms. It is an overview of various scientific approaches to the field and is of interest for all citizens as the use of mobile phones is widely spread. In the first article it is shown how a model has been built to assess the distribution of the whole body exposure of the population. The second article reviews the state of the art in personal exposure measurements at radio-frequencies. The third article shows that the knowledge of the mechanism of action by which exposure increases the risk of health hazards is necessary. The fourth article shows that individual neuro-psychic factors take a prominent but maybe not unique, part in electromagnetic hypersensitivity. The fifth article shows that no evidence was found to link health disturbances of electromagnetic hypersensitive individuals with radiofrequency exposure. The sixth article shows that the wireless phone is not an athermal hazard to the brain. The seventh article shows that the in utero and post-natal exposure to Wi-Fi does not damage the brains of young rats. The eighth article concludes that recent studies provide no convincing proof of deleterious effects of radiofrequency exposure on the integrity of the blood-brain barrier for specific absorption rates up to 6 W/kg. The ninth article shows that no co-genotoxic effect of radiofrequency was found at levels of exposure that did not induce heating. The tenth article confirms that industry-sponsored studies were least likely to report results suggesting effects. The last article shows that general practitioners are increasingly questioned by their patients about the issue of electromagnetic waves. (A.C.)

  7. 2016 FACET-II Science Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Hogan, Mark J., ed.

    2017-07-19

    The second in a series of FACET-II Science Workshops was held at SLAC National Accelerator Laboratory on October 17-19, 2016 [1]. The workshop drew thirty-five participants from eighteen different institutions including CERN, DESY, Ecole Polytechnique, FNAL, JAI, LBNL, LLNL, Radiabeam, Radiasoft, SLAC, Stony Brook, Strathclyde, Tech-X, Tsinghua, UC Boulder, UCLA and UT Austin. The 2015 workshop [2, 3] helped prioritize research directions for FACET-II. The 2016 workshop was focused on understanding what improvements are needed at the facility to support the next generation of experiments. All presentations are linked to the workshop website as a permanent record.

  8. Radiofrequency catheter ablation in the treatment of cardiac arrhythmias (first of two parts)

    International Nuclear Information System (INIS)

    Kou, W.H; Morady, F.

    1997-01-01

    The intravenous radiofrequency catheter inside cardiac s chambers, for inspect signals intracardiac s and to encourage, has been developed as diagnostic tool with the purpose to search arrhythmias physiology and physiopathology.Many energy sources has been used: direct energy, radiofrequency 11-15, laser 6,17, and microwave 18,19. A comparison between radiofrequency and electric energy shock has been described in cardiac arrhythmias treatment, in the present article. It has been tested the radiation biological effects and risk in Wolff Parkinson White patients as well as doctors who handling the fluoroscopy for image during the radiofrequency ablation. Has been described the following techniques: Catheter ablation radiofrequency slow way and fast way

  9. Reconfigurable radio-frequency arbitrary waveforms synthesized in a silicon photonic chip.

    Science.gov (United States)

    Wang, Jian; Shen, Hao; Fan, Li; Wu, Rui; Niu, Ben; Varghese, Leo T; Xuan, Yi; Leaird, Daniel E; Wang, Xi; Gan, Fuwan; Weiner, Andrew M; Qi, Minghao

    2015-01-12

    Photonic methods of radio-frequency waveform generation and processing can provide performance advantages and flexibility over electronic methods due to the ultrawide bandwidth offered by the optical carriers. However, bulk optics implementations suffer from the lack of integration and slow reconfiguration speed. Here we propose an architecture of integrated photonic radio-frequency generation and processing and implement it on a silicon chip fabricated in a semiconductor manufacturing foundry. Our device can generate programmable radio-frequency bursts or continuous waveforms with only the light source, electrical drives/controls and detectors being off-chip. It modulates an individual pulse in a radio-frequency burst within 4 ns, achieving a reconfiguration speed three orders of magnitude faster than thermal tuning. The on-chip optical delay elements offer an integrated approach to accurately manipulating individual radio-frequency waveform features without constraints set by the speed and timing jitter of electronics, and should find applications ranging from high-speed wireless to defence electronics.

  10. Fast beam radiofrequency spectroscopy

    International Nuclear Information System (INIS)

    Pipkin, F.M.

    1983-01-01

    The combination of a fast atom or ion beam derived from a small accelerator with radiofrequency spectroscopy methods provides a powerful method for measuring the fine structure of atomic and molecular systems. The fast beam makes possible measurements in which two separated oscillatory fields are used to obtain resonance lines whose widths are less than the natural line width due to the lifetimes of the states. The separated oscillatory field lines have, in addition, a number of features which make possible measurements with greater precision and less sensitivity to systematic errors. The fast beam also makes accessible multiple photon radiofrequency transitions whose line width is intrinsically narrower than that of the single photon transitions and which offer great potential for high precision measurements. This report focuses on the techniques and their promise. Recent measurements of the fine structure of H and He + are used as illustrations

  11. Joint Manipulation: Toward a General Theory of High-Velocity, Low-Amplitude Thrust Techniques.

    Science.gov (United States)

    Harwich, Andrew S

    2017-12-01

    The objective of this study was to describe the initial stage of a generalized theory of high-velocity, low-amplitude thrust (HVLAT) techniques for joint manipulation. This study examined the movements described by authors from the fields of osteopathy, chiropractic, and physical therapy to produce joint cavitation in both the metacarpophalangeal (MCP) joint and the cervical spine apophysial joint. This study qualitatively compared the kinetics, the similarities, and the differences between MCP cavitation and cervical facet joint cavitation. A qualitative vector analysis of forces and movements was undertaken by constructing computer-generated, simplified graphical models of the MCP joint and a typical cervical apophysial joint and imposing the motions dictated by the clinical technique. Comparing the path to cavitation of 2 modes of HVLAT for the MCP joint, namely, distraction and hyperflexion, it was found that the hyperflexion method requires an axis of rotation, the hinge axis, which is also required for cervical HVLAT. These results show that there is an analogue of cervical HVLAT in one of the MCP joint HVLATs. The study demonstrated that in a theoretical model, the path to joint cavitation is the same for asymmetric separation of the joint surfaces in the cervical spine and the MCP joints.

  12. Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.

    Science.gov (United States)

    Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H

    2016-05-01

    Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.

  13. Percutaneous radiofrequency treatment for refractory anteromedial pain of osteoarthritic knees.

    Science.gov (United States)

    Ikeuchi, Masahiko; Ushida, Takahiro; Izumi, Masashi; Tani, Toshikazu

    2011-04-01

    Although severe knee osteoarthritis with refractory pain is commonly treated surgically, this is often not an option for patients with poor health status or unwillingness to undergo major surgery. We examined the efficacy of radiofrequency application to sensory nerves as a novel alternative treatment for refractory knee pain. This study was an open-label, nonrandomized, and controlled study. Patients complaining of refractory anteromedial knee pain associated with radiological osteoarthritis (moderate or severe) were included. They were assigned to one of two groups: those receiving radiofrequency thermocoagulation (N = 18) or those receiving nerve block (N = 17), depending on the time period that they were referred to the clinic. Radiofrequency current or local anesthetics was applied to the medial retinacular nerve and the infrapatellar branch of the saphenous nerve. Western Ontario McMaster Universities osteoarthritis index score, pain visual analog scale (VAS), and patient's global assessment were assessed with a minimum follow-up of 6 months.   Radiofrequency treatment significantly decreased knee pain as measured by VAS for 12 weeks compared with the control group. In terms of responders, more patients in the RF group responded to the treatment than in the control group. The differences were statistically significant at 4 weeks, 8 weeks, and 12 weeks in pain VAS. Eight patients (44%) treated with radiofrequency rated excellent or good but only three (18%) in the control group rated good, although the difference was not statistically significant. Some patients were able to benefit substantially from radiofrequency treatment. Even if its effective period is limited, radiofrequency application is a promising treatment to alleviate refractory anteromedial knee pain with osteoarthritis. Further experience and technical improvements are needed to establish its role in the management of knee osteoarthritis. Wiley Periodicals, Inc.

  14. Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.

    Science.gov (United States)

    Luo, Fang; Lu, Jingjing; Ji, Nan

    2018-02-26

    No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.

  15. Percutaneous radiofrequency treatment of osteoid osteoma using cool-tip electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain)]. E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Avda. de Budapest s/n, 28922 Alcorcon, Madrid (Spain); Ortiz, Eduardo [Departamento de Cirugia ortopedica, Fundacion Hospital Alcorcon, Madrid (Spain)

    2005-12-15

    Objectives: To report our experience with percutaneous cool-tip radiofrequency ablation of osteoid osteomas and to evaluate clinical outcome. Methods and material: Forty-one patients with clinically and radiologically suspected osteoid osteoma were seen over a 48-month period (27 males and 14 females with a mean age of 18.7 years; range 5-43 years). Thirty-eight patients were treated by computed tomography (CT)-guided percutaneous radiofrequency ablation. The procedure was performed under regional or general anaesthesia. After location of the nidus, a 14G-bone biopsy needle is introduced into the nidus. Sampling is performed with a 17G-bone biopsy needle using a coaxial technique. The radiofrequency needle with a 10 mm active tip (cool-tip) is inserted through the biopsy needle and is connected to the radiofrequency generator for 6-8 min. Results: Primary success was obtained in 37 patients (97%) with a 100% secondary success rate. All patients are currently pain-free. No major complications occurred. Patients could resume unrestricted normal activity within 24 h. Conclusions: Percutaneous radiofrequency ablation of osteoid osteomas is an efficient and safe method that can be considered the procedure of choice for most cases.

  16. Visualizing radiofrequency-skin interaction using multiphoton microscopy in vivo.

    Science.gov (United States)

    Tsai, Tsung-Hua; Lin, Sung-Jan; Lee, Woan-Ruoh; Wang, Chun-Chin; Hsu, Chih-Ting; Chu, Thomas; Dong, Chen-Yuan

    2012-02-01

    Redundant skin laxity is a major feature of aging. Recently, radiofrequency has been introduced for nonablative tissue tightening by volumetric heating of the deep dermis. Despite the wide range of application based on this therapy, the effect of this technique on tissue and the subsequent tissue remodeling have not been investigated in detail. Our objective is to evaluate the potential of non-linear optics, including multiphoton autofluorescence and second harmonic generation (SHG) microscopy, as a non-invasive imaging modality for the real-time study of radiofrequency-tissue interaction. Electro-optical synergy device (ELOS) was used as the radiofrequency source in this study. The back skin of nude mouse was irradiated with radiofrequency at different passes. We evaluated the effect on skin immediately and 1 month after treatment with multiphoton microscopy. Corresponding histology was performed for comparison. We found that SHG is negatively correlated to radiofrequency passes, which means that collagen structural disruption happens immediately after thermal damage. After 1 month of collagen remodeling, SHG signals increased above baseline, indicating that collagen regeneration has occurred. Our findings may explain mechanism of nonablative skin tightening and were supported by histological examinations. Our work showed that monitoring the dermal heating status of RF and following up the detailed process of tissue reaction can be imaged and quantified with multiphoton microscopy non-invasively in vivo. Copyright © 2011. Published by Elsevier Ireland Ltd.

  17. Hydrothermal synthesis of magnetite particles with uncommon crystal facets

    Directory of Open Access Journals (Sweden)

    Junki Sato

    2014-09-01

    Full Text Available Hydrothermal synthesis of Fe3O4 (magnetite particles was carried out using organic compounds as morphology control agents to obtain magnetite crystals with uncommon facets. It was established that the morphology of Fe3O4 crystals obtained by hydrothermal treatment of an aqueous solution containing Fe2+ and organic compounds depended on the organic compound used. The shape of the Fe3O4 particles obtained when no additives were used was quasi-octahedral. In contrast, the addition of picolinic acid, citric acid or pyridine resulted in the formation of polyhedral crystals, indicating the presence of not only {1 1 1}, {1 0 0} and {1 1 0} facets but also high-index facets including at least {3 1 1} and {3 3 1}. When citric acid was used as an additive, octahedral crystals with {1 1 1} facets also appeared, and their size decreased as the amount of citric acid was increased. Thus, control of Fe3O4 particle morphology was achieved by a simple hydrothermal treatment using additives.

  18. Effect of radiofrequency on capacitance of low density plasma sheath

    International Nuclear Information System (INIS)

    Carneiro, L.T.; Cunha Rapozo, C. da

    1988-01-01

    It is shown that the influence of induced radiofrequency potential (V RF ) modifies the Bohm theory on ion saturation current, measured with Langmuir probes. The effect of radiofrequency potential on diode type plasma sheath resonance is also investigated. (M.C.K.)

  19. Synthesis and photocatalytic activity of mesoporous – (001) facets TiO_2 single crystals

    International Nuclear Information System (INIS)

    Dong, Yeshuo; Fei, Xuening; Zhou, Yongzhu

    2017-01-01

    Highlights: • The (001) facets of TiO_2 single crystals with mesoporous structure. • The (010) and (100) facets of TiO_2 single crystals were covered by the flower – shaped TiO_2 crystals. • This special structure could promote charge separation and provide more active sites, which will lead to a substantial increase in photocatalytic activity. - Abstract: In this work, the mesoporous – (001) facets TiO_2 single crystals have been successfully synthesized through a two-step solvothermal route without any template. Their structure and morphology were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), ultraviolet-visible (UV–vis) diffuse reflectance spectroscopy and energy dispersive X-ray spectrometer (EDX). Based on the different characteristics and atomic arrangements on each facet of anatase TiO_2 single crystals, we synthesized these mesoporous – (001) facets TiO_2 single crystals by controlling the interaction characteristics of hydrofluoric acid (HF) and isopropanol (i-PrOH) on the crystal facets. It can been seen that the (001) facets of these as-synthesized TiO_2 single crystals have a clear mesoporous structure through the SEM images and BET methods. Moreover, the other four facets were covered by the flower – shaped TiO_2 crystals with the generation of the mesoporous – (001) facets. This special and interesting morphology could promote charge separation and provide more active sites, which will lead to a substantial increase in photocatalytic activity. Moreover, it is more intuitive to reflect that the different crystal facets possess the different properties due to their atomic arrangement. Besides, according to the different synthetic routes, we proposed and discussed a plausible synthesis mechanism of these mesoporous – (001) facets TiO_2 single crystals.

  20. Eye examinations of laser and radiofrequency radiation workers

    International Nuclear Information System (INIS)

    Hocking, B.

    1988-01-01

    There are a growing number of uses of lasers and radiofrequency radiation in industry. Because these radiations may lead to various ocular effects, examinations of the eye are required for laser and radiofrequency workers as part of safe working practices. Various issues concerning these examinations are raised for discussion including: handling personal data, placement criteria, data collection, quality control, control data, the load on service providers, and costs

  1. Local facet approximation for image stitching

    Science.gov (United States)

    Li, Jing; Lai, Shiming; Liu, Yu; Wang, Zhengming; Zhang, Maojun

    2018-01-01

    Image stitching aims at eliminating multiview parallax and generating a seamless panorama given a set of input images. This paper proposes a local adaptive stitching method, which could achieve both accurate and robust image alignments across the whole panorama. A transformation estimation model is introduced by approximating the scene as a combination of neighboring facets. Then, the local adaptive stitching field is constructed using a series of linear systems of the facet parameters, which enables the parallax handling in three-dimensional space. We also provide a concise but effective global projectivity preserving technique that smoothly varies the transformations from local adaptive to global planar. The proposed model is capable of stitching both normal images and fisheye images. The efficiency of our method is quantitatively demonstrated in the comparative experiments on several challenging cases.

  2. Bray–Liebhafsky oscillatory reaction in the radiofrequency electromagnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stanisavljev, Dragomir R., E-mail: dragisa@ffh.bg.ac.rs [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia); Velikić, Zoran [Institute of Physics, University of Belgrade, Pregrevica 118, Zemun (Serbia); Veselinović, Dragan S.; Jacić, Nevena V.; Milenković, Maja C. [Faculty of Physical Chemistry, University of Belgrade, Studentski trg 12-16, P.O. Box 473, 11001 Belgrade (Serbia)

    2014-09-30

    Highlights: • Oscillatory Bray–Liebhafsky reaction is coupled with the radiofrequency radiation. • The effects of radiofrequency field on oscillatory parameters are investigated. • Radiofrequency power of up to the 0.2 W did not produced observable changes. • The explanation related with dissipative and capacitive effects is given. • Open the possibility of investigations of reactive effects on biological systems. - Abstract: Oscillatory Bray–Liebhafsky (BL) reaction is capacitively coupled with the electromagnetic radiation in the frequency range 60–110 MHz. Because of the specific reaction dynamics characterized by several characteristic parameters (induction period, period between chemical oscillations and their amplitude) it served as a good model system for the investigation of the effects of radiofrequent (RF) radiation. RF power of up to 0.2 W did not produce observable changes of the BL reaction parameters in the limit of the experiment reproductivity. Results indicate that, under the given experimental conditions, both dissipative and reactive properties of the solution are not considerably coupled with the RF electrical field.

  3. Percutaneous radiofrequency ablation for benign nodules of the thyroid gland

    International Nuclear Information System (INIS)

    Baek, Jung Hwan; Jeong, Hyun Jo; Kim, Yoon Suk; Kwak, Min Sook; Chang, Sun Hee; Rhim, Hyun Chul

    2005-01-01

    We wanted to evaluate the efficacy and safety of using ultrasound guided percutaneous radiofrequency ablation for the benign nodules of the thyroid gland. We studied 148 patients with benign thyroid nodules (200 total nodules) that were confirmed histopathologically, and we performed ultrasound guided radiofrequency ablation. The radiofrequency ablation was done 1 to 5 times per one nodule, and follow-up ultrasonography was performed one to nineteen months after the ablation procedures. The physical changes and the decrease of volume of the nodules were evaluated, and the complications related to radiofrequency ablation were observed. The mean initial nodule volume was 0.01-95.61 ml (mean; 6.83 ± SD of 10.63 ml) and the nodule volume after radiofrequency ablation was decreased to 0.00-46.56 ml (mean; 1.83 ± SD of 4.69 ml). The mean volume reduction rate was 73.2%. Reduction of more than 50% was noted in 90% of all cases. For 180 nodules (90%), the decrease was 50% or more, in 20 nodules (10%), the decrease was 49% or less. On gray-scale ultrasonogram obtained after ablation, the echogenicity of the nodules changed to darker, and on the doppler-sonogram, the vascular flow within the nodules disappeared in all cases. Most patients complained pain during or right after the procedure, but the pain was transient and subsided after medication. Two patients developed hoarseness that was improved in 1 week and 2 months, respectively. Sonoguided percutaneous radiofrequency ablation can be one of the treatments for benign nodules of the thyroid gland

  4. Knee cooled radiofrequency vs continuous radiofrequency for genicular neurotomy: preliminary experience - Crio-radiofrequenza vs radiofrequenza continua per neurotomia dei nervi genicolati: esperienza preliminare

    Directory of Open Access Journals (Sweden)

    Alfonso Papa

    2016-09-01

    Full Text Available Radiofrequency neurotomy of genicular nerves has been often used as an efficacious treatment option in all patients suffering from chronic osteoarthritis pain to provide long-term pain relief. After providing informed written consent, 80 patients with severe knee chronic osteoarthritis pain had been enrolled; patients had been divided into two groups (Group C, crioneurolysis, vs Group R, traditional radiofrequency, 40 patients for each group. Pain relief in C group was poorer and with shorter time in duration (median NRS reducing from 8 to 5. Radiofrequency can be considered as an effective, minimally invasive treat­ment for these kinds of conditions, and offers the benefit of being a fast procedure with long-term pain relief.

  5. Mechanisms for enlarging lesion size during irrigated tip radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Roman-Gonzalez, Javier; Johnson, Susan B

    2004-01-01

    INTRODUCTION: Irrigated tip radiofrequency ablation of cardiac arrhythmias was developed to increase the size of the radiofrequency-induced lesion, since cooling of the electrode tip allows use of higher power settings. The purpose of this study was to determine if the increased lesion size during...

  6. Paying attention to radiofrequency ablation therapy for neoplasms

    International Nuclear Information System (INIS)

    Wang Zhongming; Li Linsun

    2010-01-01

    Radiofrequency ablation is an effective treatment for malignant tumors. With the development of imaging technique, it has been widely used in treating different kinds of malignant tumors, such as liver cancer, lung cancer, kidney carcinoma, etc. Radiofrequency ablation has a lot of advantages. As a minimally-invasive, safe and effective treatment with less sufferings and fewer complications, this technique has attracted more and more attention of the experts both at home and abroad. (authors)

  7. Radiofrequency for the treatment of skin laxity: mith or truth*

    Science.gov (United States)

    de Araújo, Angélica Rodrigues; Soares, Viviane Pinheiro Campos; da Silva, Fernanda Souza; Moreira, Tatiane da Silva

    2015-01-01

    The nonablative radiofrequency is a procedure commonly used for the treatment of skin laxity from an increase in tissue temperature. The goal is to induce thermal damage to thus stimulate neocollagenesis in deep layers of the skin and subcutaneous tissue. However, many of these devices haven't been tested and their parameters are still not accepted by the scientific community. Because of this, it is necessary to review the literature regarding the physiological effects and parameters for application of radiofrequency and methodological quality and level of evidence of studies. A literature search was performed in MEDLINE, PEDro, SciELO, PubMed, LILACS and CAPES and experimental studies in humans, which used radiofrequency devices as treatment for facial or body laxity, were selected. The results showed that the main physiological effect is to stimulate collagen synthesis. There was no homogeneity between studies in relation to most of the parameters used and the methodological quality of studies and level of evidence for using radiofrequency are low. This fact complicates the determination of effective parameters for clinical use of this device in the treatment of skin laxity. The analyzed studies suggest that radiofrequency is effective, however the physiological mechanisms and the required parameters are not clear in the literature. PMID:26560216

  8. Optical fiber end-facet polymer suspended-mirror devices

    Science.gov (United States)

    Yao, Mian; Wu, Jushuai; Zhang, A. Ping; Tam, Hwa-Yaw; Wai, P. K. A.

    2017-04-01

    This paper presents a novel optical fiber device based on a polymer suspended mirror on the end facet of an optical fiber. With an own-developed optical 3D micro-printing technology, SU-8 suspended-mirror devices (SMDs) were successfully fabricated on the top of a standard single-mode optical fiber. Optical reflection spectra of the fabricated SU- 8 SMDs were measured and compared with theoretical analysis. The proposed technology paves a way towards 3D microengineering of the small end-facet of optical fibers to develop novel fiber-optic sensors.

  9. Buckling behavior of origami unit cell facets under compressive loads

    Science.gov (United States)

    Kshad, Mohamed Ali Emhmed; Naguib, Hani E.

    2018-03-01

    Origami structures as cores for sandwich structures are designed to withstand the compressive loads and to dissipate compressive energy. The deformation of the origami panels and the unit cell facets are the primary factors behind the compressive energy dissipation in origami structures. During the loading stage, the origami structures deform through the folding and unfolding process of the unit cell facets, and also through the plastic deformation of the facets. This work presents a numerical study of the buckling behavior of different origami unit cell elements under compressive loading. The studied origami configurations were Miura and Ron-Resch-like origami structures. Finite element package was used to model the origami structures. The study investigated the buckling behavior of the unit cell facets of two types of origami structures Miura origami and Ron-Resch-Like origami structures. The simulation was conducted using ANSYS finite element software, in which the model of the unit cell represented by shell elements, and the eigenvalues buckling solver was used to predict the theoretical buckling of the unit cell elements.

  10. The biological effects of quadripolar radiofrequency sequential application: a human experimental study.

    Science.gov (United States)

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-10-01

    An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radiofrequency applications were performed on human full-thickness skin and subcutaneous tissue specimens harvested during surgery for body contouring. In the in vivo assessments the applications were performed on two volunteer patients scheduled for body contouring surgery at the end of the study. The assessment methods were: clinical examination and medical photography, temperature measurement with thermal imaging scan, and light microscopy histological examination. The ex vivo assessments allowed for identification of the effective safety range for human application. The in vivo assessments allowed for demonstration of the biological effects of sequential radiofrequency applications. After a course of radiofrequency applications, the collagen fibers underwent an immediate heat-induced rearrangement and were partially denaturated and progressively metabolized by the macrophages. An overall thickening and spatial rearrangement was appreciated both in the collagen and elastic fibers, the latter displaying a juvenile reticular pattern. A late onset in the macrophage activation after sequential radiofrequency applications was appreciated. Our data confirm the effectiveness of sequential radiofrequency applications in obtaining attenuation of the skin wrinkles by an overall skin tightening.

  11. One-year results of the use of endovenous radiofrequency ablation utilising an optimised radiofrequency-induced thermotherapy protocol for the treatment of truncal superficial venous reflux.

    Science.gov (United States)

    Badham, George E; Dos Santos, Scott J; Lloyd, Lucinda Ba; Holdstock, Judy M; Whiteley, Mark S

    2018-06-01

    Background In previous in vitro and ex vivo studies, we have shown increased thermal spread can be achieved with radiofrequency-induced thermotherapy when using a low power and slower, discontinuous pullback. We aimed to determine the clinical success rate of radiofrequency-induced thermotherapy using this optimised protocol for the treatment of superficial venous reflux in truncal veins. Methods Sixty-three patients were treated with radiofrequency-induced thermotherapy using the optimised protocol and were followed up after one year (mean 16.3 months). Thirty-five patients returned for audit, giving a response rate of 56%. Duplex ultrasonography was employed to check for truncal reflux and compared to initial scans. Results In the 35 patients studied, there were 48 legs, with 64 truncal veins treated by radiofrequency-induced thermotherapy (34 great saphenous, 15 small saphenous and 15 anterior accessory saphenous veins). One year post-treatment, complete closure of all previously refluxing truncal veins was demonstrated on ultrasound, giving a success rate of 100%. Conclusions Using a previously reported optimised, low power/slow pullback radiofrequency-induced thermotherapy protocol, we have shown it is possible to achieve a 100% ablation at one year. This compares favourably with results reported at one year post-procedure using the high power/fast pullback protocols that are currently recommended for this device.

  12. Comparison of renal artery, soft tissue, and nerve damage after irrigated versus nonirrigated radiofrequency ablation.

    Science.gov (United States)

    Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu

    2015-01-01

    The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (Pradiofrequency group (Pradiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (Pradiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.

  13. Electromagnetic field sources in radiofrequency

    International Nuclear Information System (INIS)

    Oliveira, C.; Sebastiao, D.; Ladeira, D.; Antunes, M.; Correia, L.M.

    2010-01-01

    In the scope of the monIT Project, several measurements were made of electromagnetic fields in Portugal. This paper presents an analysis of the sources operating in the radiofrequency range, resulting from 2429 measurements in 466 locations.

  14. Fiber facet gratings for high power fiber lasers

    Science.gov (United States)

    Vanek, Martin; Vanis, Jan; Baravets, Yauhen; Todorov, Filip; Ctyroky, Jiri; Honzatko, Pavel

    2017-12-01

    We numerically investigated the properties of diffraction gratings designated for fabrication on the facet of an optical fiber. The gratings are intended to be used in high-power fiber lasers as mirrors either with a low or high reflectivity. The modal reflectance of low reflectivity polarizing grating has a value close to 3% for TE mode while it is significantly suppressed for TM mode. Such a grating can be fabricated on laser output fiber facet. The polarizing grating with high modal reflectance is designed as a leaky-mode resonant diffraction grating. The grating can be etched in a thin layer of high index dielectric which is sputtered on fiber facet. We used refractive index of Ta2O5 for such a layer. We found that modal reflectance can be close to 0.95 for TE polarization and polarization extinction ratio achieves 18 dB. Rigorous coupled wave analysis was used for fast optimization of grating parameters while aperiodic rigorous coupled wave analysis, Fourier modal method and finite difference time domain method were compared and used to compute modal reflectance of designed gratings.

  15. Some Results on facets for linear inequality in 0-1 variables

    Directory of Open Access Journals (Sweden)

    D. Sashi Bhusan

    2010-03-01

    Full Text Available The facet of Knapsack ploytope, i.e. convex hull of 0-1 points satisfying a given linear inequality has been presented in this current paper. Such type of facets plays an important role in set covering set partitioning, matroidal-intersection vertex- packing, generalized assignment and other combinatorial problems. Strong covers for facets of Knapsack ploytope has been developed in the first part of the present paper. Generating family of valid cutting planes that satisfy inequality with 0-1 variables through algorithms are the attraction of this paper.

  16. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions.

    Science.gov (United States)

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A

    2015-01-01

    standard and Level III evidence for single diagnostic blocks with at least 75% pain relief as the criterion standard. The evidence for cooled radiofrequency neurotomy in managing sacroiliac joint pain is Level II to III. The evidence for conventional radiofrequency neurotomy, intraarticular steroid injections, and periarticular injections with steroids or botulinum toxin is limited: Level III or IV. The limitations of this systematic review include inconsistencies in diagnostic accuracy studies with a paucity of high quality, replicative, and consistent literature. The limitations for therapeutic interventions include variations in technique, variable diagnostic standards for inclusion criteria, and variable results. The evidence for the accuracy of diagnostic and therapeutic effectiveness of sacroiliac joint interventions varied from Level II to Level IV.

  17. [Catheter ablation in patients with refractory cardiac arrhythmias with radiofrequency techniques].

    Science.gov (United States)

    de Paola, A A; Balbão, C E; Silva Netto, O; Mendonça, A; Villacorta, H; Vattimo, A C; Souza, I A; Guiguer Júnior, N; Portugal, O P; Martinez Filho, E E

    1993-02-01

    evaluate the efficacy of radiofrequency catheter ablation in patients with refractory cardiac arrhythmias. twenty patients with refractory cardiac arrhythmias were undertaken to electrophysiologic studies for diagnosis and radiofrequency catheter ablation of their reentrant arrhythmias. Ten patients were men and 10 women with ages varying from 13 to 76 years (mean = 42.4 years). Nineteen patients had supraventricular tachyarrhythmias: One patient had atrial tachycardia and 1 atrial fibrillation with rapid ventricular rate, 5 patients had reentrant nodal tachycardia, 12 patients had reentrant atrioventricular tachycardia and 1 patient had right ventricular outflow tract tachycardia. the mean time of the procedure was 4.1 hours. The radiofrequency current energy applied was 40-50 V for 30-40 seconds. Ablation was successful in 18/20 (90%) patients; in 15/18 (83%) of successfully treated patients the same study was done for diagnosis and radiofrequency ablation. One patient had femoral arterial occlusion and was treated with no significant sequelae. During a mean follow-up of 4 months no preexcitation or reentrant tachycardia occurred. the results of our experience with radiofrequency catheter ablation of cardiac arrhythmias suggest that this technique can benefit an important number of patients with cardiac arrhythmias.

  18. Radiofrequency ablation of hepatic metastasis: Results of treatment in forty patients

    Directory of Open Access Journals (Sweden)

    Rath G

    2008-01-01

    Full Text Available Aim: To evaluate the local control of hepatic metastasis with radiofrequency ablation treatment. Materials and Methods: We did a retrospective analysis in 40 patients treated with radiofrequency ablation for hepatic metastasis. The tumors ablated included up to two metastatic liver lesions, with primaries in breast, gastrointestinal tract, cervix, etc. Radiofrequency ablation was performed under general anesthesia in all cases, using ultrasound guidance. Radionics Cool-Tip RF System was used to deliver the treatment. Results: The median age of patients treated was 49 years. There were 13 female and 27 male patients. The median tumor size ablated was 1.5 cm (0.75-4.0 cm. A total of 52 radiofrequency ablation cycles were delivered. Successful ablation was achieved in all patients with hepatic metastasis less than 3 cm in size. Pain was the most common complication seen (75%. One patients developed skin burns. At 2-year follow-up 7.5% of patients had locally recurrent disease. Conclusions: Radiofrequency ablation is a minimally invasive treatment modality. It can be useful in a select group of patients with solitary liver metastasis of less than 3 cm size.

  19. 21 CFR 179.30 - Radiofrequency radiation for the heating of food, including microwave frequencies.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Radiofrequency radiation for the heating of food... PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation Sources § 179.30 Radiofrequency radiation for the heating of food, including microwave frequencies. Radiofrequency radiation, including...

  20. The morphological characteristics of the antebrachiocarpal joint of the cheetah (Acinonyx jubatus).

    Science.gov (United States)

    Ohale, L O C; Groenewald, H B

    2003-03-01

    A morphological study of the structures of the antebrachiocarpal (AC) joint of the cheetah was carded out by dissection of eight forelimbs obtained from four adult cheetahs culled from the Kruger National Park, Republic of South Africa. The aim was to evaluate the deviations of this joint from the normal feline pattern and to consider their possible relationship to the cheetah's adaptation to speed. Although published data on the AC joint of the other felids show general resemblance to that of the cheetah, there are nevertheless slight, but significant variations and modifications which tend to suggest adaptation to speed. The shafts of the radius and ulna of the cheetah are relatively straight and slender, with poorly developed distal ends. The ulnar notch is reduced to a very shallow concavity while the corresponding ulnar facet is a barely noticeable convexity, separated from the distal ulnar articular facet by an ill-defined groove. The movement of the distal radio-ulnar joint is highly restricted by the presence of a fibro-cartilaginous structure and a strong interrosseous membrane, limiting pronation and supination normally achieved by the rotation of the radius around the ulna. The extensor grooves at the distal extremity of the radius are deep and narrow and are guarded by prominent ridges. A thick extensor retinaculum anchors the strong extensor tendons in these grooves. The distal articular surface of the radius is concave in all directions except at the point where it moves into its stylold process. At this point it is convex in the dorsopalmar direction, with a surface that is rather deep and narrow. The proximal row of carpal bones presents a strongly convex surface, which is more pronounced in the dorsopalmar direction with the greatest convexity on the lateral aspect. Medially, there is a ridge-like concavity across the base of the tubercle, which rocks on the flexor surface of the radius, limiting excessive flexion as well as restricting lateral

  1. Simulation on Temperature Field of Radiofrequency Lesions System Based on Finite Element Method

    International Nuclear Information System (INIS)

    Xiao, D; Qian, Z; Li, W; Qian, L

    2011-01-01

    This paper mainly describes the way to get the volume model of damaged region according to the simulation on temperature field of radiofrequency ablation lesion system in curing Parkinson's disease based on finite element method. This volume model reflects, to some degree, the shape and size of the damaged tissue during the treatment with all tendencies in different time or core temperature. By using Pennes equation as heat conduction equation of radiofrequency ablation of biological tissue, the author obtains the temperature distribution field of biological tissue in the method of finite element for solving equations. In order to establish damage models at temperature points of 60 deg. C, 65 deg. C, 70 deg. C, 75 deg. C, 80 deg. C, 85 deg. C and 90 deg. C while the time points are 30s, 60s, 90s and 120s, Parkinson's disease model of nuclei is reduced to uniform, infinite model with RF pin at the origin. Theoretical simulations of these models are displayed, focusing on a variety of conditions about the effective lesion size on horizontal and vertical. The results show the binary complete quadratic non-linear joint temperature-time models of the maximum damage diameter and maximum height. The models can comprehensively reflect the degeneration of target tissue caused by radio frequency temperature and duration. This lay the foundation for accurately monitor of clinical RF treatment of Parkinson's disease in the future.

  2. [Features of the new minimally invasive techniques facet fixation system «Facet Wedge» in the treatment of degenerative diseases of the lumbar spine in elderly patients.

    Science.gov (United States)

    Byvaltsev, V A; Kalinin, A A; Okoneshnikova, A K

    2017-01-01

    The aim of the study was a comparative analysis of the clinical and radiographic effectiveness of the use of interbody fusion and open pedicle screw stabilization of simultaneous and new minimally invasive techniques facet fixation system «Facet Wedge» in the treatment of degenerative diseases of the lumbar spine in elderly patients. The study included 39 elderly patients (older than 60), which carries out the transforaminal interbody fusion Cage «T-pal»: open transpedicaular stabilization was used in 1st group (n=23), ipsilateral open transpedicular stabilization with contralateral transfaset installing titanium Cage «facet Wedge» -in 2nd group (n=16). We used intraoperative interventions and specific post-operative patient management, clinical data and radiographic outcomes for a comparative analysis of the parameters. Dynamic assessment was made in a period of 8 to 36 months after surgery (median 24 mo.). As a result, it found that the use of the system «facet Wedge» allows you to achieve the best clinical outcomes and fewer postoperative complications compared with open transpedicular stabilization in similar radiographic findings of bone block formation. Low traumatic facet fixation makes it possible to use methods for the treatment of elderly patients with degenerative diseases of the lumbosacral spine.

  3. Influence of the size of facets on point focus solar concentrators

    Energy Technology Data Exchange (ETDEWEB)

    Riveros-Rosas, David [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Col. Copilco, Coyoacan, CP 04510 DF (Mexico); Sanchez-Gonzalez, Marcelino [Centro Nacional de Energias Renovables, c/Somera 7-9, CP 28026 Madrid (Spain); Arancibia-Bulnes, Camilo A.; Estrada, Claudio A. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/n, Morelos (Mexico)

    2011-03-15

    It is a common practice in the development of point focus solar concentrators to use multiple identical reflecting facets, as a practical and economic alternative for the design and construction of large systems. This kind of systems behaves in a different manner than continuous paraboloidal concentrators. A theoretical study is carried out to understand the effect of the size of facets and of their optical errors in multiple facet point focus solar concentrating systems. For this purpose, a ray tracing program was developed based on the convolution technique, in which the brightness distribution of the sun and the optical errors of the reflecting surfaces are considered. The study shows that both the peak of concentration and the optimal focal distance of the system strongly depend on the size of the facets, and on their optical errors. These results are useful to help concentrator developers to have a better understanding of the relationship between manufacturing design restrictions and final optical behavior. (author)

  4. Facets of emotional awareness and associations with emotion regulation and depression.

    Science.gov (United States)

    Boden, Matthew Tyler; Thompson, Renee J

    2015-06-01

    Emotion theories posit that effective emotion regulation depends upon the nuanced information provided by emotional awareness; attending to and understanding one's own emotions. Additionally, the strong associations between facets of emotional awareness and various forms of psychopathology may be partially attributable to associations with emotion regulation. These logically compelling hypotheses are largely uninvestigated, including which facets compose emotional awareness and how they relate to emotion regulation strategies and psychopathology. We used exploratory structural equation modeling of individual difference measures among a large adult sample (n = 919) recruited online. Results distinguished 4 facets of emotional awareness (type clarity, source clarity, involuntary attention to emotion, and voluntary attention to emotion) that were differentially associated with expressive suppression, acceptance of emotions, and cognitive reappraisal. Facets were associated with depression both directly and indirectly via associations with emotion regulation strategies. We discuss implications for theory and research on emotional awareness, emotion regulation, and psychopathology. (c) 2015 APA, all rights reserved).

  5. Job Stress, Employee Health, and Organizational Effectiveness: A Facet Analysis, Model, and Literature Review.

    Science.gov (United States)

    Beehr, Terry A.; Newman, John E.

    1978-01-01

    The empirical research on job stress and employee health is reviewed within the context of six facets (environmental, personal, process, human consequences, organizational consequences, and time) of a seven facet conceptualization of the job stress-employee health research domain. Models are proposed for tying the facets together. (Author/SJL)

  6. A practical scale for Multi-Faceted Organizational Health Climate Assessment.

    Science.gov (United States)

    Zweber, Zandra M; Henning, Robert A; Magley, Vicki J

    2016-04-01

    The current study sought to develop a practical scale to measure 3 facets of workplace health climate from the employee perspective as an important component of a healthy organization. The goal was to create a short, usable yet comprehensive scale that organizations and occupational health professionals could use to determine if workplace health interventions were needed. The proposed Multi-faceted Organizational Health Climate Assessment (MOHCA) scale assesses facets that correspond to 3 organizational levels: (a) workgroup, (b) supervisor, and (c) organization. Ten items were developed and tested on 2 distinct samples, 1 cross-organization and 1 within-organization. Exploratory and confirmatory factor analyses yielded a 9-item, hierarchical 3-factor structure. Tests confirmed MOHCA has convergent validity with related constructs, such as perceived organizational support and supervisor support, as well as discriminant validity with safety climate. Lastly, criterion-related validity was found between MOHCA and health-related outcomes. The multi-faceted nature of MOHCA provides a scale that has face validity and can be easily translated into practice, offering a means for diagnosing the shortcomings of an organization or workgroup's health climate to better plan health and well-being interventions. (c) 2016 APA, all rights reserved).

  7. Randomized Sham-controlled Double-Blind Multicenter Clinical Trial to Ascertain the Effect of Percutaneous Radiofrequency Treatment for Sacroiliac Joint Pain: Three-month Results

    NARCIS (Netherlands)

    C.W.J. van Tilburg (Cornelis); F.A. Schuurmans (Fleur A.); D.L. Stronks (Dirk); J.G. Groeneweg (George); F.J.P.M. Huygen

    2016-01-01

    markdownabstractObjectives: To investigate the effect of a percutaneous radiofrequency (RF) heat lesion compared with a sham procedure, applied to the lateral branches of L5, S1, S2, S3, and S4 nerve roots. Materials and Methods: Sixty patients aged 18 years and above with a medical history and

  8. Progress report for FACETS (Framework Application for Core-Edge Transport Simulations): C.S. SAP

    Energy Technology Data Exchange (ETDEWEB)

    Epperly, T W

    2008-10-01

    The mission of the Computer Science Scientific Application Partnership (C.S. SAP) at LLNL is to develop and apply leading-edge scientific component technology to FACETS software. Contributions from LLNL's fusion energy program staff towards the underlying physics modules are described in a separate report. FACETS uses component technology to combine selectively multiple physics and solver software modules written in different languages by different institutions together in an tightly-integrated, parallel computing framework for Tokamak reactor modeling. In the past fiscal year, the C.S. SAP has focused on two primary tasks: applying Babel to connect UEDGE into the FACETS framework through UEDGE's existing Python interface and developing a next generation componentization strategy for UEDGE which avoids the use of Python. The FACETS project uses Babel to solve its language interoperability challenges. Specific accomplishments for the year include: (1) Refined SIDL interfaces for UEDGE to meet satisfy the standard interfaces required by FACETS for all physics modules. This required consensus building between framework and UEDGE developers. (2) Wrote prototype C++ driver for UEDGE to demonstrate how UEDGE can be called from C++ using Babel. (3) Supported the FACETS project by adding new features to Babel such as release number tagging, porting to new machines, and adding new configuration options. Babel modifications were delivered to FACETS by testing and publishing development snapshots in the projects software repository. (4) Assisted Tech-X Corporation in testing and debugging of a high level build system for the complete FACETS tool chain--the complete list of third-party software libraries that FACETS depends on directly or indirectly (e.g., MPI, HDF5, PACT, etc.). (5) Designed and implemented a new approach to wrapping UEDGE as a FACETS component without requiring Python. To get simulation results as soon as possible, our initial connection from the

  9. Progress report for FACETS (Framework Application for Core-Edge Transport Simulations): C.S. SAP

    International Nuclear Information System (INIS)

    Epperly, T.W.

    2008-01-01

    The mission of the Computer Science Scientific Application Partnership (C.S. SAP) at LLNL is to develop and apply leading-edge scientific component technology to FACETS software. Contributions from LLNL's fusion energy program staff towards the underlying physics modules are described in a separate report. FACETS uses component technology to combine selectively multiple physics and solver software modules written in different languages by different institutions together in an tightly-integrated, parallel computing framework for Tokamak reactor modeling. In the past fiscal year, the C.S. SAP has focused on two primary tasks: applying Babel to connect UEDGE into the FACETS framework through UEDGE's existing Python interface and developing a next generation componentization strategy for UEDGE which avoids the use of Python. The FACETS project uses Babel to solve its language interoperability challenges. Specific accomplishments for the year include: (1) Refined SIDL interfaces for UEDGE to meet satisfy the standard interfaces required by FACETS for all physics modules. This required consensus building between framework and UEDGE developers. (2) Wrote prototype C++ driver for UEDGE to demonstrate how UEDGE can be called from C++ using Babel. (3) Supported the FACETS project by adding new features to Babel such as release number tagging, porting to new machines, and adding new configuration options. Babel modifications were delivered to FACETS by testing and publishing development snapshots in the projects software repository. (4) Assisted Tech-X Corporation in testing and debugging of a high level build system for the complete FACETS tool chain--the complete list of third-party software libraries that FACETS depends on directly or indirectly (e.g., MPI, HDF5, PACT, etc.). (5) Designed and implemented a new approach to wrapping UEDGE as a FACETS component without requiring Python. To get simulation results as soon as possible, our initial connection from the FACETS

  10. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation

    Directory of Open Access Journals (Sweden)

    Yeon Jin Choi

    2012-01-01

    Full Text Available Background: As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. Aim: To compare Polaris WRA TM , a combination device of diode light and RF, and ReFirme ST TM , a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Methods: Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm 2 , RF fluence 90 J/cm 3 on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm 3 on the left half of their faces. Clinical photos of front and bilateral sides of the subjects′ faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators′ and the subjects′ global assessments were performed. Results: There is no statistically significant difference in the overall outcome between Polaris WRA TM and Refirme ST TM based on pre- and post-treatment objective measurements. Polaris WRA TM was more effective than Refirme ST TM at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA TM -treated facial area than that of Refirme ST TM . Treatment was generally well tolerated, and there was no serious complication. Conclusion: In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at

  11. The safety and efficacy of a combined diode laser and bipolar radiofrequency compared with combined infrared light and bipolar radiofrequency for skin rejuvenation.

    Science.gov (United States)

    Choi, Yeon Jin; Lee, Jung Yeon; Ahn, Ji Young; Kim, Myeung Nam; Park, Mi Youn

    2012-01-01

    As the demand for noninvasive procedures for skin rejuvenation is increasing, combined diode laser and radiofrequency and combined infrared and radiofrequency devices have recently emerged. To compare Polaris WRA(TM), a combination device of diode light and RF, and ReFirme ST(TM), a combination device of infrared and bipolar RF, in terms of safety and efficacy on skin rejuvenation. Fourteen Korean volunteers of skin type II-IV, with facial laxity and periorbital rhytids, received three treatments at 3-week intervals with combined diode laser and bipolar radiofrequency (laser fluence 30 J/cm2, RF fluence 90 J/cm3) on the right half of their faces and combined infrared light and bipolar radiofrequency (RF fluence 120 J/cm3) on the left half of their faces. Clinical photos of front and bilateral sides of the subjects' faces were taken at baseline and at 6, 9, 12 weeks after the treatment initiation. The investigators' and the subjects' global assessments were performed. There is no statistically significant difference in the overall outcome between Polaris WRA(TM) and Refirme ST(TM) based on pre- and post-treatment objective measurements. Polaris WRA(TM) was more effective than Refirme ST(TM) at reducing wrinkles when therapeutic results of the two appliances were compared based on the patient satisfaction measurements. After the treatment with both instruments, histological increase in the production and rearrangement of collagen fibers at the dermal layer was observed. The density of the collagen fibers was more increased with the Polaris WRA(TM)-treated facial area than that of Refirme ST(TM). Treatment was generally well tolerated, and there was no serious complication. In this study, both the lasers appeared to be safe, and effective methods for treating skin laxity and facial wrinkles. Combined diode laser and radiofrequency was more effective than combined infrared and radiofrequency at reducing wrinkles and pores when the therapeutic results of both the

  12. 12-month efficacy of a single radiofrequency ablation on autonomously functioning thyroid nodules.

    Science.gov (United States)

    Bernardi, Stella; Stacul, Fulvio; Michelli, Andrea; Giudici, Fabiola; Zuolo, Giulia; de Manzini, Nicolò; Dobrinja, Chiara; Zanconati, Fabrizio; Fabris, Bruno

    2017-09-01

    Radiofrequency ablation has been advocated as an alternative to radioiodine and/or surgery for the treatment of autonomously functioning benign thyroid nodules. However, only a few studies have measured radiofrequency ablation efficacy on autonomously functioning benign thyroid nodules. The aim of this work was to evaluate the 12-month efficacy of a single session of radiofrequency ablation (performed with the moving shot technique) on solitary autonomously functioning benign thyroid nodules. Thirty patients with a single, benign autonomously functioning benign thyroid nodules, who were either unwilling or ineligible to undergo surgery and radioiodine, were treated with radiofrequency ablation between April 2012 and May 2015. All the patients underwent a single radiofrequency ablation, performed with the 18-gauge needle and the moving shot technique. Clinical, laboratory, and ultrasound evaluations were scheduled at baseline, and after 1, 3, 6, and 12 months from the procedure. A single radiofrequency ablation reduced thyroid nodule volume by 51, 63, 69, and 75 % after 1, 3, 6, and 12 months, respectively. This was associated with a significant improvement of local cervical discomfort and cosmetic score. As for thyroid function, 33 % of the patients went into remission after 3 months, 43 % after 6 months, and 50 % after 12 months from the procedure. This study demonstrates that a single radiofrequency ablation allowed us to withdraw anti-thyroid medication in 50 % of the patients, who remained euthyroid afterwards. This study shows that a single radiofrequency ablation was effective in 50 % of patients with autonomously functioning benign thyroid nodules. Patients responded gradually to the treatment. It is possible that longer follow-up studies might show greater response rates.

  13. WORKSHOP: Radiofrequency superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-10-15

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators.

  14. WORKSHOP: Radiofrequency superconductivity

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The Second Workshop on Radiofrequency Superconductivity was held at CERN from 23-27 July, four years after the first, organized at Karlsruhe. 35 invited talks were presented to the about 80 participants from Australia, Brazil, Europe, Japan and the United States. For the first time, ten Laboratories operating or planning superconducting accelerators for heavy ions participated and shared their experience with the community proposing the use of superconducting accelerating sections for electron accelerators

  15. Surface Area of Patellar Facets: Inferential Statistics in the Iraqi Population

    Directory of Open Access Journals (Sweden)

    Ahmed Al-Imam

    2017-01-01

    Full Text Available Background. The patella is the largest sesamoid bone in the body; its three-dimensional complexity necessitates biomechanical perfection. Numerous pathologies occur at the patellofemoral unit which may end in degenerative changes. This study aims to test the presence of statistical correlation between the surface areas of patellar facets and other patellar morphometric parameters. Materials and Methods. Forty dry human patellae were studied. The morphometry of each patella was measured using a digital Vernier Caliper, electronic balance, and image analyses software known as ImageJ. The patellar facetal surface area was correlated with patellar weight, height, width, and thickness. Results. Inferential statistics proved the existence of linear correlation of total facetal surface area and patellar weight, height, width, and thickness. The correlation was strongest for surface area versus patellar weight. The lateral facetal area was found persistently larger than the medial facetal area, the p value was found to be <0.001 (one-tailed t-test for right patellae, and another significant p value of < 0.001 (one-tailed t-test was found for left patellae. Conclusion. These data are vital for the restoration of the normal biomechanics of the patellofemoral unit; these are to be consulted during knee surgeries and implant designs and can be of an indispensable anthropometric, interethnic, and biometric value.

  16. Cross-cultural evidence for the two-facet structure of pride

    Science.gov (United States)

    Shi, Yan; Chung, Joanne M.; Cheng, Joey T.; Tracy, Jessica L.; Robins, Richard W.; Chen, Xiao; Zheng, Yong

    2016-01-01

    Across six studies conducted in Mainland China and South Korea, the present research extended prior findings showing that pride is comprised of two distinct conceptual and experiential facets in the U.S.: a pro-social, achievement-oriented “authentic pride”, and an arrogant, self-aggrandizing “hubristic pride”. This same two-facet structure emerged in Chinese participants’ semantic conceptualizations of pride (Study 1), Chinese and Koreans’ dispositional tendencies to experience pride (Studies 2, 3a, and 3b), Chinese and Koreans’ momentary pride experiences (Studies 3a, 3b, and 5), and Americans’ pride experiences using descriptors derived indigenously in Korea (Study 4). Together, these studies provide the first evidence that the two-facet structure of pride generalizes to cultures with highly divergent views of pride and self-enhancement processes from North America. PMID:27158171

  17. Cross-cultural evidence for the two-facet structure of pride.

    Science.gov (United States)

    Shi, Yan; Chung, Joanne M; Cheng, Joey T; Tracy, Jessica L; Robins, Richard W; Chen, Xiao; Zheng, Yong

    2015-04-01

    Across six studies conducted in Mainland China and South Korea, the present research extended prior findings showing that pride is comprised of two distinct conceptual and experiential facets in the U.S.: a pro-social, achievement-oriented "authentic pride", and an arrogant, self-aggrandizing "hubristic pride". This same two-facet structure emerged in Chinese participants' semantic conceptualizations of pride (Study 1), Chinese and Koreans' dispositional tendencies to experience pride (Studies 2, 3a, and 3b), Chinese and Koreans' momentary pride experiences (Studies 3a, 3b, and 5), and Americans' pride experiences using descriptors derived indigenously in Korea (Study 4). Together, these studies provide the first evidence that the two-facet structure of pride generalizes to cultures with highly divergent views of pride and self-enhancement processes from North America.

  18. Exploring the relationship between facets of mindfulness and eating pathology in women.

    Science.gov (United States)

    Lavender, Jason M; Gratz, Kim L; Tull, Matthew T

    2011-01-01

    Although researchers have examined the efficacy of acceptance- and mindfulness-based interventions in the treatment of eating disorders, few studies have explored the association between trait mindfulness and eating pathology. Therefore, the purpose of the current investigation was to examine the unique associations between multiple facets of mindfulness (acting with awareness, nonreactivity, nonjudgment, describing, and observing) and eating pathology. Undergraduate women (N = 276) completed the Eating Attitudes Test-26, the Five Facet Mindfulness Questionnaire, and the 21-item version of the Depression Anxiety Stress Scales. A hierarchical regression analysis revealed that four mindfulness facets (awareness, nonreactivity, nonjudgment, and describing) were uniquely associated with eating pathology above and beyond anxiety and depression symptoms. Results are discussed with regard to the potential role of various facets of trait mindfulness in eating pathology as well as the possible utility of mindfulness-based treatments for eating disorders.

  19. Rotational injury of cervical facets: CT analysis of fracture patterns with implications for management and neurologic outcome.

    Science.gov (United States)

    Shanmuganathan, K; Mirvis, S E; Levine, A M

    1994-11-01

    Imaging studies of patients with rotational facet injuries of the cervical spine were retrospectively reviewed to determine the prevalence and pattern of associated fractures, to correlate injury pattern with recommended surgical stabilization, and to assess neurologic outcome. Radiographs and CT scans obtained for 40 consecutive patients with rotational facet injuries of the cervical spine during a 70-month period were retrospectively reviewed to determine injury level, presence, and orientation of facet fractures, and concurrent nonfacet injuries. Imaging findings were reviewed to assess the likelihood of instability and to determine the most appropriate stabilization requirement. Medical records were reviewed to ascertain mechanism of injury, initial neurologic deficit, and surgical findings. Among the 40 patients with cervical rotational facet injuries, 11 (27%) had pure unilateral facet dislocation or subluxation without associated fractures, and 29 (73%) had concurrent facet fractures involving the inferior facet of the rotated vertebra (n = 13), the superior facet of the subjacent vertebra (n = 9), or both (n = 7). Injury of the rotated vertebra was unilateral in 22 patients but bilateral in 18 patients. Facet fractures frequently extended into the ipsilateral lamina or articular pillar or both. An avulsion fracture from the posteroinferior aspect of the rotated vertebral body, indicating disk disruption, occurred in 10 patients (25%), and seven patients (17%) had complete isolation of an articular pillar. Facet fractures were confirmed for 27 patients who underwent surgical stabilization. Neurologic deficits developed in 29 (73%) of the 40 patients and included radiculopathy in 11 patients and cord syndromes in 18 patients. Pure dislocation without a facet fracture was more likely to lead to a cord syndrome (p = .006). Cervical rotational facet injuries are often accompanied by facet fractures and bilateral damage of the rotated vertebra. These injuries

  20. Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung Hee; Yun, Chung Bang [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Inman, Daniel J. [Virginia Polytechnic Institute and State University, Virginia (United States)

    2007-06-15

    This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure

  1. Remote Impedance-based Loose Bolt Inspection Using a Radio-Frequency Active Sensing Node

    International Nuclear Information System (INIS)

    Park, Seung Hee; Yun, Chung Bang; Inman, Daniel J.

    2007-01-01

    This paper introduces an active sensing node using radio-frequency (RF) telemetry. This device has brought the traditional impedance-based structural health monitoring (SHM) technique to a new paradigm. The RF active sensing node consists of a miniaturized impedance measuring device (AD5933), a microcontroller (ATmega128L), and a radio frequency (RF) transmitter (XBee). A macro-fiber composite (MFC) patch interrogates a host structure by using a self-sensing technique of the miniaturized impedance measuring device. All the process including structural interrogation, data acquisition, signal processing, and damage diagnostic is being performed at the sensor location by the microcontroller. The RF transmitter is used to communicate the current status of the host structure. The feasibility of the proposed SHM strategy is verified through an experimental study inspecting loose bolts in a bolt-jointed aluminum structure

  2. Segmental translation after lumbar total disc replacement using Prodisc-L®: associated factors and relation to facet arthrosis.

    Science.gov (United States)

    Shin, Myung H; Ryu, Kyeong S; Rathi, Nitesh K; Park, Chun K

    2017-02-01

    Segmental translation after lumbar total disc replacement (TDR) with ProDisc-L® prosthesis frequently observed radiographic findings during follow-up period. However its precise pathomechanism and relation with facet arthrosis have not been investigated yet. This study was performed to evaluate possible factors that affect postoperative segmental translation and to identify its relation with facet joint degeneration after lumbar TDR using ProDisc-L® prosthesis. Thirty-five consecutive patients, who underwent lumbar TDR using ProDisc-L®, completed minimum 24 months follow-up. Segmental translation was assessed postoperatively at 1 month and at least at 24 months by using dynamic plain radiograph. Segmental translation was assessed in relation to patient age, sex, change of functional spinal unit (FSU) height, segmental range of motion (ROM), global lumbar ROM, implanted level, relative prosthesis size and prosthesis position. The comparison of segmental translation between progressive facet arthrosis (PFA) group and non-PFA group was also made. The mean segmental translation was 0.49±0.49 mm at 1 month after surgery and showed significant increase to 0.83±0.78 mm at last follow-up (P=0.014). Change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis were the significant factors among the variables related to segmental translation that authors assessed (P=0.032, P=0.000, P=0.001, P=0.046 and P=0.042, respectively). There was no significant intergroup difference of mean segmental translation between PFA group and non-PFA group (P=0.586). This study demonstrates that segmental translation after TDR using ProDisc-L® has significant relations with change of FSU height, segmental ROM, global lumbar ROM, implanted level and relative size of prosthesis. With the intergroup comparison, PFA group did not show significant higher segmental translation than non-PFA group.

  3. Controlled synthesis and facets-dependent photocatalysis of TiO2 nanocrystals

    Science.gov (United States)

    Roy, Nitish; Park, Yohan; Sohn, Youngku; Pradhan, Debabrata

    2015-04-01

    Titanium dioxide (TiO2) is a wide band gap semiconductor that has been extensively used in several environmental applications including degradation of organic hazardous chemicals, water splitting to generate hydrogen, dye sensitized solar cells, self cleaning agents, and pigments. Herein we demonstrate the synthesis of TiO2 nanocrystals (NCs) with the shapes of ellipsoids, rods, cuboids, and sheets with different exposed facets using a noncorrosive and nontoxic chemical (i.e. diethanolamine) as the shape controlling agent, unlike hydrofluoric acid commonly used. The TiO2 NCs of diverse shapes with different exposed facets were tested for photocatalytic hydroxyl radical (OH•) formation, which determines their photocatalytic behavior and the results were compared with the standard P-25 Degussa. The formation rate of OH• per specific surface area was found to be >6 fold higher for rod-shaped TiO2 NCs than that of commercial Degussa P25 catalyst. The highest photocatalytic activity of rod-shaped TiO2 NCs is ascribed to the unique chemical environment of {010} exposed facets which facilitates the electron/hole separation in presence of {101} facets.

  4. CO-CO coupling on Cu facets: Coverage, strain and field effects

    International Nuclear Information System (INIS)

    Sandberg, Robert B.; Montoya, Joseph H.; Chan, Karen; Nørskov, Jens K.

    2016-01-01

    We present a DFT study on the effect of coverage, strain, and electric field on CO-CO coupling energetics on Cu (100), (111), and (211). Our calculations indicate that CO-CO coupling is facile on all three facets in the presence of a cation-induced electric field in the Helmholtz plane, with the lowest barrier on Cu(100). The CO dimerization pathway is therefore expected to play a role in C_2 formation at potentials negative of the Cu potential of zero charge, corresponding to CO_2/CO reduction conditions at high pH. Both increased *CO coverage and tensile strain further improve C-C coupling energetics on Cu (111) and (211). Since CO dimerization is facile on all 3 Cu facets, subsequent surface hydrogenation steps may also play an important role in determining the overall activity towards C_2 products. Adsorption of *CO, *H, and *OH on the 3 facets were investigated with a Pourbaix analysis. Here, the (211) facet has the largest propensity to co-adsorb *CO and *H, which would favor surface hydrogenation following CO dimerization.

  5. Cooling system for the IFMIF-EVEDA radiofrequency system

    International Nuclear Information System (INIS)

    Perez Pichel, G. D.

    2012-01-01

    The IFMIF-EVEDA project consists on an accelerator prototype that will be installed at Rokkasho (Japan). Through CIEMAT, that is responsible of the development of many systems and components. Empresarios Agrupados get the responsibility of the detailed design of the cooling system for the radiofrequency system (RF system) that must feed the accelerator. the RF water cooling systems is the water primary circuit that provides the required water flow (with a certain temperature, pressure and water quality) and also dissipates the necessary thermal power of all the radiofrequency system equipment. (Author) 4 refs.

  6. Fraxelated radiofrequency device for acne scars

    Science.gov (United States)

    Rao, Babar K.; Khokher, Sairah

    2012-09-01

    Acne scars can be improved with various treatments such as topical creams, chemical peels, dermal fillers, microdermabrasion, laser, and radiofrequency devices. Some of these treatments especially lasers and deep chemical peels can have significant side effects such as post inflammatory hyperpigmentation in darker skin types. Fraxelated RF Laser devices have been reported to have lower incidence of side effects in all skin phototypes. Nine patients between ages 18 and 35 of various skin phototypes were selected from a private practice and treated with a RF fraxelated device (E-matrix) for acne scars. Outcomes were measured by physician observation, subjective feedback received by patients, and comparison of before and after photographs. In this small group of patients with various skin phototypes, fraxelated radiofrequency device improved acne scars with minimal side effects and downtime.

  7. Transurethral radiofrequency collagen denaturation for the treatment of women with urinary incontinence.

    Science.gov (United States)

    Kang, Diana; Han, Julia; Neuberger, Molly M; Moy, M Louis; Wallace, Sheila A; Alonso-Coello, Pablo; Dahm, Philipp

    2015-03-18

    Transurethral radiofrequency collagen denaturation is a relatively novel, minimally invasive device-based intervention used to treat individuals with urinary incontinence (UI). No systematic review of the evidence supporting its use has been published to date. To evaluate the efficacy of transurethral radiofrequency collagen denaturation, compared with other interventions, in the treatment of women with UI.Review authors sought to compare the following.• Transurethral radiofrequency collagen denaturation versus no treatment/sham treatment.• Transurethral radiofrequency collagen denaturation versus conservative physical treatment.• Transurethral radiofrequency collagen denaturation versus mechanical devices (pessaries for UI).• Transurethral radiofrequency collagen denaturation versus drug treatment.• Transurethral radiofrequency collagen denaturation versus injectable treatment for UI.• Transurethral radiofrequency collagen denaturation versus other surgery for UI. We conducted a systematic search of the Cochrane Incontinence Group Specialised Register (searched 19 December 2014), EMBASE and EMBASE Classic (January 1947 to 2014 Week 50), Google Scholar and three trials registries in December 2014, along with reference checking. We sought to identify unpublished studies by handsearching abstracts of major gynaecology and urology meetings, and by contacting experts in the field and the device manufacturer. Randomised and quasi-randomised trials of transurethral radiofrequency collagen denaturation versus no treatment/sham treatment, conservative physical treatment, mechanical devices, drug treatment, injectable treatment for UI or other surgery for UI in women were eligible. We screened search results and selected eligible studies for inclusion. We assessed risk of bias and analysed dichotomous variables as risk ratios (RRs) with 95% confidence intervals (CIs) and continuous variables as mean differences (MDs) with 95% CIs. We rated the quality of

  8. Ion collection from laser-induced plasma by applying radio-frequency voltage

    International Nuclear Information System (INIS)

    Shibata, Takemasa; Ogura, Koichi

    1995-01-01

    Ions were collected on the electrodes from a laser resonance photoionized plasma by applying 1.8MHz radio-frequency voltage to the electrode. It was demonstrated that the ions are collected in a shorter time at the same kinetic energy of the collected ions compared with ion collection by applying DC voltage to the electrode. A simple one-dimensional model was extended for prediction of ion collection times in the cases of applications of not only the DC voltage but also the radio-frequency voltage. The ion collection times estimated using the simple one-dimensional model agreed with experimental values in both cases of DC and radio-frequency voltages. (author)

  9. Faceting of stepped silicon (1 1 3) surfaces: Self assembly of nanoscale gratings

    Science.gov (United States)

    Mochrie, S. G. J.; Song, S.; Yoon, Mirang; Abernathy, D. L.; Stephenson, G. B.

    1996-02-01

    Synchrotron X-ray scattering studies of the phase behavior and phase transformations of stepped Si(113) surfaces tilted towards [001] are reviewed for temperatures between 300 and 1500 K. At the highest temperatures, these surfaces are uniformly stepped, and the intensity of near-specularly scattered X-rays increases with decreasing temperature. This is two-dimensional critical opalescence, which foreshadows a faceting transformation. At temperatures below the faceting transformation, (113) facets appear in coexistence with a stepped phase, leading to a mesoscopically grooved morphology. Both the misorientation angle at the phase boundary separating one- and two-phase regions and the intensity of the near-specular diffuse scattering may be described as power laws versus reduced temperature. This can be understood qualitatively on the basis of a mean-field theory, which incorporates an attractive interaction between steps. At lower temperatures, the surfaces are completely faceted, comprising (114) and (113) facets. The kinetics of faceting is also described. Following a quench from a one-phase region of the phase diagram into a two-phase region, the grooved superstructure forms and subsequently coarsens in time. For times between one and several hundred seconds, the surface morphology is self-similar at different times, with a characteristic groove size that evolves as a power law versus time. At later times, the groove size approaches a limiting value, as a result of elastic effects.

  10. Effect of Radiofrequency Endometrial Ablation on Dysmenorrhea.

    Science.gov (United States)

    Wyatt, Sabrina N; Banahan, Taylor; Tang, Ying; Nadendla, Kavita; Szychowski, Jeff M; Jenkins, Todd R

    To examine rates of dysmenorrhea after radiofrequency endometrial ablation in patients with and without known dysmenorrhea symptoms prior to the procedure in a diverse population. Retrospective cohort study (Canadian Task Force classification II-2). Academic gynecology practice. A total of 307 women underwent endometrial ablation between 2007 and 2013 at our institution. Patients who had preoperative and postoperative pain symptom assessments as well as a description of pain timing recorded were included in our analysis. Exclusion criteria were age dysmenorrhea was evaluated. Demographic information and other outcome variables were used to evaluate factors associated with resolution of dysmenorrhea. A total of 307 patients who underwent radiofrequency endometrial ablation were identified. After exclusions, 296 charts were examined, and 144 patients met our enrollment criteria. The mean age of the study cohort was 45.4 ± 6.2 years; 57 patients (40%) were African American, 16 (11%) had a body mass index (BMI) > 40, and 41 (29%) were of normal weight. Preoperative dysmenorrhea was reported by 100 patients (69%); 48 of these patients (48%) experienced resolution of symptoms postoperatively. Only 3 of the 44 patients (7%) without preoperative dysmenorrhea reported new-onset dysmenorrhea postoperatively. Significantly fewer patients had dysmenorrhea after compared to before radiofrequency ablation (55 of 144 [38%] vs 100 of 144 [69%]; p dysmenorrhea after ablation was associated with reduction in bleeding volume (p = .048) but not with a reduction in frequency of bleeding (p = .12). Approximately one-half of women who undergo radiofrequency endometrial ablation to treat heavy menstrual bleeding who also have preoperative dysmenorrhea exhibit documented pain resolution after the procedure. Resolution of dysmenorrhea is more likely if menstrual flow volume is decreased postprocedure. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  11. Patterns of astragalar fibular facet orientation in extant and fossil primates and their evolutionary implications.

    Science.gov (United States)

    Boyer, Doug M; Seiffert, Erik R

    2013-07-01

    A laterally sloping fibular facet of the astragalus (=talus) has been proposed as one of few osteological synapomorphies of strepsirrhine primates, but the feature has never been comprehensively quantified. We describe a method for calculating fibular facet orientation on digital models of astragali as the angle between the planes of the fibular facet and the lateral tibial facet. We calculated this value in a sample that includes all major extant primate clades, a diversity of Paleogene primates, and nonprimate euarchontans (n = 304). Results show that previous characterization of a divide between extant haplorhines and strepsirrhines is accurate, with little overlap even when individual data points are considered. Fibular facet orientation is conserved in extant strepsirrhines despite major differences in locomotion and body size, while extant anthropoids are more variable (e.g., low values for catarrhines relative to non-callitrichine platyrrhines). Euprimate outgroups exhibit a mosaic of character states with Cynocephalus having a more obtuse strepsirrhine-like facet and sampled treeshrews and plesiadapiforms having more acute haplorhine-like facets. Surprisingly, the earliest species of the adapiform Cantius have steep haplorhine-like facets as well. We used a Bayesian approach to reconstruct the evolution of fibular facet orientation as a continuous character across a supertree of living and extinct primates. Mean estimates for crown Primatomorpha (97.9°), Primates (99.5°), Haplorhini (98.7°), and Strepsirrhini (108.2°) support the hypothesis that the strepsirrhine condition is derived, while lower values for crown Anthropoidea (92.8°) and Catarrhini (88.9°) are derived in the opposite direction. Copyright © 2013 Wiley Periodicals, Inc.

  12. FACET: A simulation software framework for modeling complex societal processes and interactions

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, J. H.

    2000-06-02

    FACET, the Framework for Addressing Cooperative Extended Transactions, was developed at Argonne National Laboratory to address the need for a simulation software architecture in the style of an agent-based approach, but with sufficient robustness, expressiveness, and flexibility to be able to deal with the levels of complexity seen in real-world social situations. FACET is an object-oriented software framework for building models of complex, cooperative behaviors of agents. It can be used to implement simulation models of societal processes such as the complex interplay of participating individuals and organizations engaged in multiple concurrent transactions in pursuit of their various goals. These transactions can be patterned on, for example, clinical guidelines and procedures, business practices, government and corporate policies, etc. FACET can also address other complex behaviors such as biological life cycles or manufacturing processes. To date, for example, FACET has been applied to such areas as land management, health care delivery, avian social behavior, and interactions between natural and social processes in ancient Mesopotamia.

  13. The HEXACO correlates of authoritarianism's facets in the U.S. and Denmark

    DEFF Research Database (Denmark)

    Liu, Jie; Ludeke, Steven G.; Zettler, Ingo

    2017-01-01

    was the predictable differences in the relations the facets had with Honesty-Humility, which was more positively related to conventionalism than authoritarian aggression in the U.S. sample, but not in the Danish sample. Interestingly, the U.S. sample scored significantly higher in authoritarianism and its facets than...

  14. Radiofrequency Ablation Effectively Treated Focal Recurrence of Mesothelioma.

    Science.gov (United States)

    Nakamura, Akifumi; Takuwa, Teruhisa; Hashimoto, Masaki; Kondo, Nobuyuki; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Hasegawa, Seiki

    2018-02-01

    A 55-year-old man with malignant pleural mesothelioma underwent multimodality treatment comprising induction chemotherapy followed by extrapleural pneumonectomy and radiation therapy. After 2.5 years, focal recurrence occurred, with computed tomography revealing a tumor in the left cardiophrenic angle. Surgery was considered a problem for the patient because of the previous extrapleural pneumonectomy and difficult tumor location. Radiofrequency ablation was thus performed; the course was uneventful, and there was no recurrence. Radiofrequency ablation should be considered an option to treat recurrence of malignant pleural mesothelioma. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  16. An Examination of the Multi-Faceted Motivation System in Healthy Young Adults

    Directory of Open Access Journals (Sweden)

    Susana Da Silva

    2018-05-01

    Full Text Available Background: Amotivation is a prevalent symptom in schizophrenia (SZ and depression (MDD, and is linked to poor functional outcomes in affected individuals. Conceptualizations of motivation have outlined a multi-faceted construct comprised of reward responsiveness, reward expectancy, reward valuation, effort valuation, and action selection/preference-based decision making. To date, findings from studies utilizing variable-centered approaches to examining isolated facets of motivation in SZ and MDD have been inconsistent. Thus, the present study adopted a person-centered approach, and comprehensively examined the reward system in a non-clinical sample in an attempt to explore potential subtypes of motivation impairments, while minimizing the effects of illness-related confounds.Methods: Ninety-six healthy undergraduate students were evaluated for amotivation, schizotypal traits, depressive symptoms, and cognition, and administered objective computerized tasks to measure the different facets of motivation. Cluster analysis was performed to explore subgroups of individuals based on similar motivation task performance. Additionally, correlational analyses were conducted in order to examine inter-relationships between motivation facets, and relations between clinical measures and facets of motivation.Results: Cluster analysis identified two subgroups of individuals with differential motivation performance profiles. Correlational analyses revealed that reward responsiveness was associated with amotivation, depressive symptoms, and negative schizotypy. Further, significant inter-correlations were found between reward responsiveness and reward expectancy, as well as between reward valuation and effort valuation.Conclusions: Our results mark important steps forward in understanding motivation in a non-clinical sample, and guide future dimensional and comprehensive analyses of the multi-faceted reward system. It remains to be seen whether these patterns of

  17. An Examination of the Multi-Faceted Motivation System in Healthy Young Adults.

    Science.gov (United States)

    Da Silva, Susana; Apatsidou, Areti; Saperia, Sarah; Siddiqui, Ishraq; Jeffay, Eliyas; Voineskos, Aristotle N; Daskalakis, Zafiris J; Remington, Gary; Zakzanis, Konstantine K; Foussias, George

    2018-01-01

    Background: Amotivation is a prevalent symptom in schizophrenia (SZ) and depression (MDD), and is linked to poor functional outcomes in affected individuals. Conceptualizations of motivation have outlined a multi-faceted construct comprised of reward responsiveness, reward expectancy, reward valuation, effort valuation, and action selection/preference-based decision making. To date, findings from studies utilizing variable-centered approaches to examining isolated facets of motivation in SZ and MDD have been inconsistent. Thus, the present study adopted a person-centered approach, and comprehensively examined the reward system in a non-clinical sample in an attempt to explore potential subtypes of motivation impairments, while minimizing the effects of illness-related confounds. Methods: Ninety-six healthy undergraduate students were evaluated for amotivation, schizotypal traits, depressive symptoms, and cognition, and administered objective computerized tasks to measure the different facets of motivation. Cluster analysis was performed to explore subgroups of individuals based on similar motivation task performance. Additionally, correlational analyses were conducted in order to examine inter-relationships between motivation facets, and relations between clinical measures and facets of motivation. Results: Cluster analysis identified two subgroups of individuals with differential motivation performance profiles. Correlational analyses revealed that reward responsiveness was associated with amotivation, depressive symptoms, and negative schizotypy. Further, significant inter-correlations were found between reward responsiveness and reward expectancy, as well as between reward valuation and effort valuation. Conclusions: Our results mark important steps forward in understanding motivation in a non-clinical sample, and guide future dimensional and comprehensive analyses of the multi-faceted reward system. It remains to be seen whether these patterns of results will

  18. Posterior longitudinal ligament status in cervical spine bilateral facet dislocations

    International Nuclear Information System (INIS)

    Carrino, John A.; Manton, Geoffrey L.; Morrison, William B.; Flanders, Adam E.; Vaccaro, Alex R.; Schweitzer, Mark E.

    2006-01-01

    It is generally accepted that cervical spine bilateral facet dislocation results in complete disruption of the posterior longitudinal ligament. The goal of this study was to evaluate the integrity of numerous spine-stabilizing structures by MRI, and to determine if any associations between injury patterns exist with respect to the posterior longitudinal ligament status. Retrospective case series. A retrospective review was performed of 30 cervical spine injury subjects with bilateral facet dislocation. Assessment of 1.5T MRI images was carried out for: intervertebral disc disruption, facet fracture, and ligamentous disruption. Statistical analyses were performed to evaluate for associations between various injury patterns and posterior longitudinal ligament status. The frequency of MRI abnormalities was: anterior longitudinal ligament disruption (26.7%), disc herniation or disruption (90%), posterior longitudinal ligament disruption (40%), facet fracture (63.3%) and disruption of the posterior column ligament complex (97%). There were no significant associations between injury to the posterior longitudinal ligament and other structures. Compared to surgical reports, MRI was accurate for determining the status for 24 of 26 ligaments (three of three anterior longitudinal ligament, seven of nine posterior longitudinal ligament, and 14 of 14 posterior column ligament complex) but generated false negatives in two instances (in both MRI showed an intact posterior longitudinal ligament that was torn at surgery). (orig.)

  19. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  20. Dioptrics of the facet lenses in the dorsal rim area of the cricket Gryllus bimaculatus

    NARCIS (Netherlands)

    Ukhanov, KY; Leertouwer, HL; Gribakin, FG; Stavenga, DG

    1996-01-01

    1. The optics of the corneal facet lenses from the dorsal rim area (DRA) and from the dorso-lateral areas (DA) of the compound eye of the cricket Gryllus bimaculatus were studied. 2. The DRA of the cricket eye contains quite normally shaped facet lenses. The diameter of the facet lens in the DA is

  1. Feasibility of Noninvasive Temperature Assessment During Radiofrequency Liver Ablation on Computed Tomography

    NARCIS (Netherlands)

    Pandeya, Ganga D.; Greuter, Marcel J. W.; de Jong, Koert P.; Schmidt, Bernhard; Flohr, Thomas; Oudkerk, Matthijs

    2011-01-01

    Purpose: The purpose of this study was to assess the feasibility of noninvasive thermometry using high-resolution computer tomography (CT) for the monitoring of bovine liver during radiofrequency (RF) ablation. Methods: Radiofrequency probes were used to ablate bovine livers from 20 degrees C to 98

  2. Ophthalmic branch radiofrequency thermocoagulation for atypical trigeminal neuralgia:a case report.

    Science.gov (United States)

    Du, Shibin; Ma, Xiaoliang; Li, Xiaoqin; Yuan, Hongjie

    2015-01-01

    Trigeminal neuralgia is an intense neuralgia involving facial areas supplied by trigeminal nerve. The pain is characterized by sudden onset, short persistence, sharp or lancinating. Trigeminal neuralgia commonly affects frontal areas, infraorbital or paranasal areas, mandibular areas and teeth. While Trigeminal neuralgia affecting merely the upper eyelid is rare. Here we report a case of atypical Trigeminal neuralgia confined to the upper eyelid. The patient was pain free during the follow-up period of 6 months after unusual ophthalmic branch radiofrequency thermocoagulation. A 55-year-old female patient was diagnosed as primary trigeminal neuralgia involving the right upper eyelid. As the pain could not be controlled by drug therapy, peripheral nerve branch radiofrequency thermocoagulation was recommended. A combination of infratrochlear, supratrochlear and lacrimal radiofrequency thermocoagulation was implemented in this case. The point where the bridge of the nose abuts the supraorbital ridge and the point slightly above the lateral canthus along outer border of the orbit were selected respectively as the puncture sites. After positive diagnostic test, radiofrequency thermocoagulation of the above-mentioned nerve branches was performed respectively. The patient was pain free immediately after the treatment and during the follow-up period of 6 months. Trigeminal neuralgia is a common severe and chronic facial neuralgia which requires accurate diagnosis and effective therapy. With typical clinical symptoms, normal neurological signs, normal CT and MRI findings, the patient was diagnosed as classic trigeminal neuralgia. As the patient was drug resistant, some invasive treatments were considered. Peripheral branch neurolysis was chosen for its minimal invasiveness, convenience, low risk and not affecting further invasive treatments. According to the anatomic data and the diagnostic test results, infratrochlear, supratrochlear and lacrimal nerve were responsible

  3. Sphenopalatine ganglion: block, radiofrequency ablation and neurostimulation - a systematic review.

    Science.gov (United States)

    Ho, Kwo Wei David; Przkora, Rene; Kumar, Sanjeev

    2017-12-28

    Sphenopalatine ganglion is the largest collection of neurons in the calvarium outside of the brain. Over the past century, it has been a target for interventional treatment of head and facial pain due to its ease of access. Block, radiofrequency ablation, and neurostimulation have all been applied to treat a myriad of painful syndromes. Despite the routine use of these interventions, the literature supporting their use has not been systematically summarized. This systematic review aims to collect and summarize the level of evidence supporting the use of sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on sphenopalatine ganglion block, radiofrequency ablation and neurostimulation. Studies included in this review were compiled and analyzed for their treated medical conditions, study design, outcomes and procedural details. Studies were graded using Oxford Center for Evidence-Based Medicine for level of evidence. Based on the level of evidence, grades of recommendations are provided for each intervention and its associated medical conditions. Eighty-three publications were included in this review, of which 60 were studies on sphenopalatine ganglion block, 15 were on radiofrequency ablation, and 8 were on neurostimulation. Of all the studies, 23 have evidence level above case series. Of the 23 studies, 19 were on sphenopalatine ganglion block, 1 study on radiofrequency ablation, and 3 studies on neurostimulation. The rest of the available literature was case reports and case series. The strongest evidence lies in using sphenopalatine ganglion block, radiofrequency ablation and neurostimulation for cluster headache. Sphenopalatine ganglion block also has evidence in treating trigeminal neuralgia, migraines, reducing the needs of analgesics after endoscopic sinus surgery and reducing pain associated with nasal packing

  4. Influence of the austenitizing temperature in the cleavage facet size of Niocor 2

    International Nuclear Information System (INIS)

    Darwish, F.A.I.; Teixeira, J.C.G.; Fernandes, R.A.; Juer, S.

    1983-01-01

    Convetional Charpy specimens of Niocor 2 steel cooled in air from various austenitizing temperatures were fractured at -196 0 C so as to insure failure by cleavage. The cleavage facet size distribution was determined and then correlated with the grain size and other aspects of the microstructure. The results that the average facet size can be increased through a coarsening of the microstructure. For the case where the γ→α transformation products are predominantely acicular, the facet size is shown to depend on substructural aspects primarily the lath packet size. (Author) [pt

  5. Contact characteristics of the subtalar joint after a simulated calcaneus fracture.

    Science.gov (United States)

    Sangeorzan, B J; Ananthakrishnan, D; Tencer, A F

    1995-06-01

    A simple calcaneus fracture consisting of two parts was modeled in nine fresh cadaver hindfoot specimens to assess changes in subtalar joint contact characteristics with increasing plantar depression of the posterolateral fracture component. To perform the experiment, rods were placed in the tibial and fibular shafts of each specimen, which was mounted in a frame in neutral stance. A pneumatic cylinder was used to deliver a vertical compressive load through the rods into the foot while permitting free motion of the foot in the horizontal plane. Sealed packets of pressure-sensitive film were inserted into the anterior-middle and posterior facets of the talocalcaneal articulation, and a 700-N load was applied. After testing of the intact foot, a primary fracture line was created using a microoscillating saw. The osteotomized posterolateral component was anatomically reduced and fixed, the film inserted, and the load reapplied. The test was repeated after the posterolateral fragment was displaced 2, 5, and 10 mm in a plantar direction. The resulting pressure prints were scanned along with pressure/color density calibration strips using a flat-bed scanner, and an image analysis system was used to determine contact areas within specified pressure intervals. The contact area (> 0.5 MPa) of the posterior facet was significantly decreased with 2, 5, and 10 mm displacements of the posterolateral calcaneus fracture component. The ratio of high-pressure area (< 5.0 MPa) to contact area in the posterior facet was significantly increased only with displacements of 5 and 10 mm. There were no significant changes in any contact parameters in the anterior-middle facet.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. On the relative importance of bending and compression in cervical spine bilateral facet dislocation.

    Science.gov (United States)

    Nightingale, Roger W; Bass, Cameron R; Myers, Barry S

    2018-03-08

    Cervical bilateral facet dislocations are among the most devastating spine injuries in terms of likelihood of severe neurological sequelae. More than half of patients with tetraparesis had sustained some form of bilateral facet fracture dislocation. They can occur at any level of the sub-axial cervical spine, but predominate between C5 and C7. The mechanism of these injuries has long been thought to be forceful flexion of the chin towards the chest. This "hyperflexion" hypothesis comports well with intuition and it has become dogma in the clinical literature. However, biomechanical studies of the human cervical spine have had little success in producing this clinically common and devastating injury in a flexion mode of loading. The purpose of this manuscript is to review the clinical and engineering literature on the biomechanics of bilateral facet dislocations and to describe the mechanical reasons for the causal role of compression, and the limited role of head flexion, in producing bilateral facet dislocations. Bilateral facet dislocations have only been produced in experiments where compression is the primary loading mode. To date, no biomechanical study has produced bilateral facet dislocations in a whole spine by bending. Yet the notion that it is primarily a hyper-flexion injury persists in the clinical literature. Compression and compressive buckling are the primary causes of bilateral facet dislocations. It is important to stop using the hyper-flexion nomenclature to describe this class of cervical spines injuries because it may have a detrimental effect on designs for injury prevention. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Improving personality facet scores with multidimensional computer adaptive testing: an illustration with the Neo Pi-R

    NARCIS (Netherlands)

    Makransky, Guido; Mortensen, Erik Lykke; Glas, Cornelis A.W.

    2013-01-01

    Narrowly defined personality facet scores are commonly reported and used for making decisions in clinical and organizational settings. Although these facets are typically related, scoring is usually carried out for a single facet at a time. This method can be ineffective and time consuming when

  8. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  9. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  10. Long-wave plasma radiofrequency ablation for treatment of xanthelasma palpebrarum.

    Science.gov (United States)

    Baroni, Adone

    2018-03-01

    Xanthelasma palpebrarum is the most common type of xanthoma affecting the eyelids. It is characterized by asymptomatic soft yellowish macules, papules, or plaques over the upper and lower eyelids. Many treatments are available for management of xanthelasma palpebrarum, the most commonly used include surgical excision, ablative CO 2 or erbium lasers, nonablative Q-switched Nd:YAG laser, trichloroacetic acid peeling, and radiofrequency ablation. This study aims to evaluate the effectiveness of RF ablation in the treatment of xanthelasma palpebrarum, with D.A.S. Medical portable device (Technolux, Italia), a radiofrequency tool working with long-wave plasma energy and without anesthesia. Twenty patients, 15 female and 5 male, affected by xanthelasma palpebrarum, were enrolled for long-wave plasma radiofrequency ablation treatment. The treatment consisted of 3/4 sessions that were carried out at intervals of 30 days. Treatments were well tolerated by all patients with no adverse effects and optimal aesthetic results. The procedure is very fast and can be performed without anesthesia because of the low and tolerable pain stimulation. Long-wave plasma radiofrequency ablation is an effective option for treatment of xanthelasma palpebrarum and adds an additional tool to the increasing list of medical devices for aesthetic treatments. © 2018 Wiley Periodicals, Inc.

  11. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  12. Big Five Personality Factors and Facets as Predictors of Openness to Diversity.

    Science.gov (United States)

    Han, Suejung; Pistole, M Carole

    2017-11-17

    Openness to diversity is a crucial component of cultural competence needed in the increasingly diversified modern society and a necessary condition for benefitting from diversity contacts and interventions (e.g., diversity training, cultural courses). Responding to the recent call for more research on personality and its relation to diversity outcomes, we examined the associations between Big Five personality (i.e., Openness to Experience, Agreeableness, Extraversion, Neuroticism, and Conscientiousness) higher order factors and lower order facets and universal-diverse orientation (i.e., open attitude of appreciating human universality and diversity; Miville et al., 1999 ). In the Study 1 (N = 338) web survey on Big Five factors, Openness to Experience and Agreeableness were associated with universal-diverse orientation significantly. In the Study 2 (N = 176) paper survey on both Big Five factors and facets, Openness to Experience, low Neuroticism, and Conscientiousness, and various lower-order facets of all the Big Five personality were associated with universal-diverse orientation significantly. Practical implications were suggested on how personality facets could be incorporated into current diversity interventions to enhance their effectiveness of promoting openness to diversity.

  13. Unique relationships between facets of mindfulness and eating pathology among female smokers.

    Science.gov (United States)

    Adams, Claire E; Apperson McVay, Megan; Kinsaul, Jessica; Benitez, Lindsay; Vinci, Christine; Stewart, Diana W; Copeland, Amy L

    2012-12-01

    Female smokers often have higher levels of eating disorder symptoms than non-smokers, and concerns about eating and weight might interfere with smoking cessation. Thus, it is critical to identify factors to promote healthier eating and body image in this population. Initial research suggests that specific aspects of trait mindfulness predict lower body dissatisfaction and eating disorder symptoms among non-smokers. However, these relationships are unknown among smokers. The current study examined associations between facets of trait mindfulness and eating disorder symptoms in 112 college female smokers (83% Caucasian; mean age 20 years, SD=1.69). After controlling for relevant sociodemographic variables, Describing and Nonjudging facets of mindfulness predicted lower bulimic symptoms and body dissatisfaction (psmindfulness facets are related to lower eating disorder symptoms among smokers, whereas other facets are not associated or have a positive relationship with these symptoms. Mindfulness-based interventions focusing on Describing, Nonjudging, and Acting with Awareness may help to reduce eating pathology among female smokers, which could potentially improve smoking cessation rates in this population. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Radiofrequency energy in the arthroscopic treatment of knee chondral lesions: a systematic review.

    Science.gov (United States)

    Rocco, Papalia; Lorenzo, Diaz Balzani; Guglielmo, Torre; Michele, Paciotti; Nicola, Maffulli; Vincenzo, Denaro

    2016-03-01

    Cartilage debridement is one of the recommended procedures for the management of chondral defects. Radiofrequency probes allow to debride the cartilage, but may induce subchondral bone necrosis. Medline, Cochrane and Google Scholar were searched to identify studies on arthroscopic debridement of the articular cartilage of the knee using radiofrequency chondroplasty. The methodological quality of the studies was assessed using the Coleman methodology score (CMS). Monopolar and bipolar radiofrequency devices provide significantly better clinical outcomes, especially for patients with high-grade chondral lesions, compared with mechanical shaver only. Despite the original concerns regarding subchondral bone necrosis, low complication rates are reported. Heterogeneity in terms of type of device does not allow sound comparison of the published results. There is lack of evidence on the long-term effects of radiofrequency chondroplasty. Study methodology should be improved: the average Coleman methodology score was 56.2 out of 100. More comparative, well-designed and larger cohort trials are needed to ascertain whether radiofrequency chondroplasty offers long-term benefits over other simpler and more economical alternatives. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Trait and facet-level predictors of first-onset depressive and anxiety disorders in a community sample of adolescent girls.

    Science.gov (United States)

    Goldstein, Brandon L; Kotov, Roman; Perlman, Greg; Watson, David; Klein, Daniel N

    2017-09-20

    Individual differences in neuroticism, extraversion, and conscientiousness are associated with, and may predict onset of, internalizing disorders. These general traits can be parsed into facets, but there is a surprising paucity of research on facet risk for internalizing disorders. We examined general traits and facets of neuroticism, extraversion, and conscientiousness in predicting first onsets of depressive and anxiety disorders. A community sample of 550 adolescent females completed general and facet-level personality measures and diagnostic interviews. Interviews were re-administered 18 months later. First onsets of depressive disorders were predicted by neuroticism, extraversion, and conscientiousness. Facets predicting first onset of depression included depressivity (neuroticism facet) and lower positive emotionality and sociability (extraversion facets). First onsets of generalized anxiety disorder (GAD) were predicted by neuroticism, and particularly the facet of anxiousness. First onsets of social phobia were predicted at the facet level by anxiousness. First onsets of specific phobia were predicted by neuroticism, low conscientiousness, and all neuroticism facets. In multivariate analyses, first onsets of depression were uniquely predicted by depressivity, and onsets of GAD and social phobia were uniquely predicted by anxiousness over and above the general trait of neuroticism. General traits predict first onsets of depressive and anxiety disorders. In addition, more specific associations are evident at the facet level. Facets can refine our understanding of the links between personality and psychopathology risk, and provide finer-grained targets for personality-informed interventions.

  16. Framework Application for Core Edge Transport Simulation (FACETS)

    Energy Technology Data Exchange (ETDEWEB)

    Krasheninnikov, Sergei; Pigarov, Alexander

    2011-10-15

    The FACETS (Framework Application for Core-Edge Transport Simulations) project of Scientific Discovery through Advanced Computing (SciDAC) Program was aimed at providing a high-fidelity whole-tokamak modeling for the U.S. magnetic fusion energy program and ITER through coupling separate components for each of the core region, edge region, and wall, with realistic plasma particles and power sources and turbulent transport simulation. The project also aimed at developing advanced numerical algorithms, efficient implicit coupling methods, and software tools utilizing the leadership class computing facilities under Advanced Scientific Computing Research (ASCR). The FACETS project was conducted by a multi-discipline, multi-institutional teams, the Lead PI was J.R. Cary (Tech-X Corp.). In the FACETS project, the Applied Plasma Theory Group at the MAE Department of UCSD developed the Wall and Plasma-Surface Interaction (WALLPSI) module, performed its validation against experimental data, and integrated it into the developed framework. WALLPSI is a one-dimensional, coarse grained, reaction/advection/diffusion code applied to each material boundary cell in the common modeling domain for a tokamak. It incorporates an advanced model for plasma particle transport and retention in the solid matter of plasma facing components, simulation of plasma heat power load handling, calculation of erosion/deposition, and simulation of synergistic effects in strong plasma-wall coupling.

  17. Influence of higher order modes on angled-facet amplifiers

    DEFF Research Database (Denmark)

    Wang, Z.; Mikkelsen, B.; Stubkjær, Kristian

    1991-01-01

    The influence of the first-order mode on the residual reflectivity of angled-facet amplifiers is analyzed. For a 7 degrees angled-facet ridge waveguide amplifier with a single-layer antireflective (AR) coating, a gain ripple lower than 1-dB at 25-dB gain can be obtained independent...... of the polarization, even in the presence of a first-order mode with a 15-dB gain. The tolerances for the thickness and refractive index of the AR coating are reduced by a factor of three compared to operation in the fundamental mode only. The influence of the higher order mode can virtually be suppressed...

  18. b-tree facets for the simple graph partitioning polytope

    DEFF Research Database (Denmark)

    Sørensen, Michael Malmros

    2004-01-01

    The simple graph partitioning problem is to partition an edge-weighted graph into mutually disjoint subgraphs, each consisting of no more than b nodes, such that the sum of the weights of all edges in the subgraphs is maximal. In this paper we introduce a large class of facet defining inequalities...... for the simple graph partitioning polytopes P_n(b), b >= 3, associated with the complete graph on n nodes. These inequalities are induced by a graph configuration which is built upon trees of cardinality b. We provide a closed-form theorem that states all necessary and sufficient conditions for the facet...... defining property of the inequalities. Udgivelsesdato: JUN...

  19. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    International Nuclear Information System (INIS)

    Choi, Ji Won; Yoo, Seung Min; Kwak, Seo Hyun

    2005-01-01

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 ρ 0.5 mm in group I and 11.4 ρ 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal wall

  20. Ultrasound-guided radiofrequency ablation of thyroid gland: a preliminary study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Yoo, Seung Min [College of Medicine, Chungang University, Seoul, (Korea, Republic of); Kwak, Seo Hyun [Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2005-07-15

    The purpose of this study was to evaluate the possibility of using radiofrequency ablation as the treatment modality for the benign or malignant thyroid nodules in humans. Therefore, we examined the results of using radiofrequency ablation on the thyroid glands in dogs, in respect of the extent of the ablated tissue and the complications. Five dogs (10 lobes of the thyroid glands) were included in this study. US-guided radiofrequency ablation was undertaken with a 10 mm, uncovered 17 gauge cool-tip needle. The power and duration was 20 wattage and 1 minute in five thyroid lobes (group 1) and 20 wattage and 2 minutes in another 5 thyroid lobes (group 2). The ultrasound scans and the pre-and post-enhancement CT scans were undertaken before and immediately after the procedures, and at 24 hours, 72 hours and 1 week later. The US and CT findings of the ablated tissue and complications were evaluated. Blood sampling was done at the pre-procedure time and 1 week later for evaluating the functional status of the thyroid gland. Laryngoscopy was done at the pre-procedure and post-procedure times, and at 24 hours, 72 hours and 1 week later for the evaluation of any recurrent laryngeal nerve palsy. The echo pattern of the ablated thyroid gland at immediately after the radiofrequency ablation appeared as poorly marginated and hyperechoic. On the US obtained 24 hours after radiofrequency ablation, the echo pattern of the ablated thyroid gland was hypoechoic. The maximum diameters after RFA were 9.4 {rho} 0.5 mm in group I and 11.4 {rho} 0.5 mm in group II. The pre-enhanced CT scan taken at immediately after the radiofrequency ablation showed ill defined hypodense areas in the ablated thyroid gland. Differentiation between the normal and abnormal portions of the thyroid gland was difficult on the contrast enhanced CT scan. Complications induced by radiofrequency ablation were one recurrent laryngeal nerve palsy, two perforations of esophagus and five thickenings of the esophageal

  1. What’s in a word? : Rethinking facet headings in a discovery service

    Directory of Open Access Journals (Sweden)

    David Nelson

    2015-06-01

    Full Text Available The emergence of Discovery systems has been well received by libraries who have long been concerned with offering a smorgasbord of databases that require either individual searching of databases or the problematic use of federated searching.  The ability to search across a wide array of subscribed and open-access information resources via a centralized index has opened up access for users to a library’s wealth of information resources.  This capability has been particularly praised for its ‘google like’ search interface, thereby conforming to user expectations for information searching.  Yet, all discovery services also include facets as a search capability and thus provide faceted navigation which is a search feature that Google is not particularly well suited for.  Discovery services thus provide a hybrid search interface.  An examination of e-commerce sites clearly shows that faceted navigation is an integral part of their discovery systems.  Many library OPACs also now are being developed with faceted navigation capabilities.  However, the discovery services faceted structures suffer from a number of problems which inhibit their usefulness and their potential.  This article examines a number of these issues and it offers suggestions for improving the discovery search interface.  It also argues that vendors and libraries need to work together to more closely analyze the user experience of the discovery system.

  2. Stepwise radiofrequency ablation of Barrett's esophagus preserves esophageal inner diameter, compliance, and motility

    NARCIS (Netherlands)

    Beaumont, H.; Gondrie, J. J.; McMahon, B. P.; Pouw, R. E.; Gregersen, H.; Bergman, J. J.; Boeckxstaens, G. E.

    2009-01-01

    Background and aim: Stepwise endoscopic circumferential and focal radiofrequency ablation is safe and effective for the eradication of Barrett's esophagus. In contrast to other techniques, radiofrequency ablation appears to avoid significant esophageal scarring or stenosis. Our aim was to evaluate

  3. Preliminary Conceptual Design Report for the FACET-II Project at SLAC National Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Hogan, Mark [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-04-22

    Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10μ by 10μ transversely with a bunch length of 10μ. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes

  4. Polygons and Faceted Polyhedra and Nanoporous Networks.

    Science.gov (United States)

    Lu, Jianjiang; Mondal, Arunendu; Moulton, Brian; Zaworotko, Michael J

    2001-06-01

    Small rhombihexahedra and small cubicuboctahedra, namely faceted polyhedra, form the basis of two novel low-density framework solids that are afforded by the self-assembly of molecular squares only or molecular squares and triangles, respectively. © 2001 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  5. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  6. Sensing the facet orientation in silver nano-plates using scanning Kelvin probe microscopy in air

    Energy Technology Data Exchange (ETDEWEB)

    Abdellatif, M.H. [Department of Nanostructures, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova (Italy); Physics Department, National Research Center, Elbehoos st., 12622, Dokki, Giza (Egypt); Salerno, M., E-mail: marco.salerno@iit.it [Department of Nanophysics, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova (Italy); Polovitsyn, Anatolii [Department of Nanochemistry, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova (Italy); Dipartimentodi Fisica, Università di Genova, via Dodecaneso 33, I-16146 Genova (Italy); Marras, Sergio [Department of Nanochemistry, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova (Italy); De Angelis, Francesco [Department of Nanostructures, Istituto Italiano di Tecnologia, via Morego 30, I-16163 Genova (Italy)

    2017-05-01

    Highlights: • The surface potential of drop cast nanocrystals was measured by SKPM in ambient air. • The nanocrystal facet work function was derived by theory. • By comparing theory and experiment we distinguished the nanocrystal facets. • Nanocrystal facet control is of practical interest for optoelectronic devices. - Abstract: The work function of nano-materials is important for a full characterization of their electronic properties. Because the band alignment, band bending and electronic noise are very sensitive to work function fluctuations, the dependence of the work function of nano-scale crystals on facet orientation can be a critical issue in optimizing optoelectronic devices based on these materials. We used scanning Kelvin probe microscopy to assess the local work function on samples of silver nano-plates at sub-micrometric spatial resolution. With the appropriate choice of the substrate and based on statistical analysis, it was possible to distinguish the surface potential of the different facets of silver nano-plates even if the measurements were done in ambient conditions without the use of vacuum. A phenomenological model was used to calculate the differences of facet work function of the silver nano-plates and the corresponding shift in Fermi level. This theoretical prediction and the experimentally observed difference in surface potential on the silver nano-plates were in good agreement. Our results show the possibility to sense the nano-crystal facets by appropriate choice of the substrate in ambient conditions.

  7. Sensing the facet orientation in silver nano-plates using scanning Kelvin probe microscopy in air

    International Nuclear Information System (INIS)

    Abdellatif, M.H.; Salerno, M.; Polovitsyn, Anatolii; Marras, Sergio; De Angelis, Francesco

    2017-01-01

    Highlights: • The surface potential of drop cast nanocrystals was measured by SKPM in ambient air. • The nanocrystal facet work function was derived by theory. • By comparing theory and experiment we distinguished the nanocrystal facets. • Nanocrystal facet control is of practical interest for optoelectronic devices. - Abstract: The work function of nano-materials is important for a full characterization of their electronic properties. Because the band alignment, band bending and electronic noise are very sensitive to work function fluctuations, the dependence of the work function of nano-scale crystals on facet orientation can be a critical issue in optimizing optoelectronic devices based on these materials. We used scanning Kelvin probe microscopy to assess the local work function on samples of silver nano-plates at sub-micrometric spatial resolution. With the appropriate choice of the substrate and based on statistical analysis, it was possible to distinguish the surface potential of the different facets of silver nano-plates even if the measurements were done in ambient conditions without the use of vacuum. A phenomenological model was used to calculate the differences of facet work function of the silver nano-plates and the corresponding shift in Fermi level. This theoretical prediction and the experimentally observed difference in surface potential on the silver nano-plates were in good agreement. Our results show the possibility to sense the nano-crystal facets by appropriate choice of the substrate in ambient conditions.

  8. A facet approach to extending the normative component of the theory of reasoned action.

    Science.gov (United States)

    Donald, I; Cooper, S R

    2001-12-01

    Using facet theory, this study addresses the weak explanatory power of normative influence in theories of reasoned action or planned behaviour. A broad normative construct is hypothesized as being characterized by two facets--social unit and behavioural modality--each of which is examined in relation to recreational drug use. A questionnaire was developed from the facets and administered to undergraduate students. Data (N = 181) were analysed using Smallest Space Analysis (SSA). The results suggest that the facets provide an adequate description of the normative construct and that personal and social normative beliefs, behavioural norms and behavioural intentions can be distinguished empirically. The results also lend partial support to Ajzen's (1988; Ajzen & Fishbein, 1977) principle of compatibility. Implications for how social influence is operationalized and conceptualized are also discussed.

  9. Influence of radiofrequency surgery on architecture of the palatine tonsils.

    Science.gov (United States)

    Plzak, Jan; Macokova, Pavla; Zabrodsky, Michal; Kastner, Jan; Lastuvka, Petr; Astl, Jaromir

    2014-01-01

    Radiofrequency surgery is a widely used modern technique for submucosal volume reduction of the tonsils. So far there is very limited information on morphologic changes in the human tonsils after radiofrequency surgery. We performed histopathological study of tonsillectomy specimens after previous bipolar radiofrequency induced thermotherapy (RFITT). A total of 83 patients underwent bipolar RFITT for hypertrophy of palatine tonsils. Tonsil volume reduction was measured by 3D ultrasonography. Five patients subsequently underwent tonsillectomy. Profound histopathological examination was performed to determine the effect of RFITT on tonsillar architecture. All tonsillectomy specimens showed the intact epithelium, intact germinal centers, normal vascularization, and no evidence of increased fibrosis. No microscopic morphological changes in tonsillectomy specimens after bipolar RFITT were observed. RFITT is an effective submucosal volume reduction procedure for treatment of hypertrophic palatine tonsils with no destructive effect on microscopic tonsillar architecture and hence most probably no functional adverse effect.

  10. Systematic Review of Radiofrequency Ablation and Pulsed Radiofrequency for Management of Cervicogenic Headaches.

    Science.gov (United States)

    Grandhi, Ravi K; Kaye, Alan David; Abd-Elsayed, Alaa

    2018-02-23

    Cervicogenic headache (CHA) is a secondary headache which has a source in the upper cervical spine. Many traditional analgesic choices lack good efficacy in managing the associated pain. As a result, in management of CHA, radiofrequency ablation (RFA) or pulse radiofrequency (PRF) has been tried with success. Our study investigated the use of RFA and PRF for the management of CHA. In the present investigation, a review of the literature was conducted using PubMed (1966 to February 2017). The quality assessment was determined using The Cochrane Risk of Bias. After initial search and consultation with experts, 34 articles were identified for initial review and 10 articles met inclusion for review. Criteria for inclusion were primarily based on identification of articles discussing cervicogenic headaches which were previously treatment resistant and occurred without any other pathology of the craniofacial region or inciting event such as trauma. This systematic review demonstrated that RFA and PRFA provide very limited benefit in the management of CHA. At present, there is no high-quality RCT and/or strong non-RCTs to support the use of these techniques, despite numerous case reports which have demonstrated benefit. This review is one of the first to provide a comprehensive overview of the use of RFA and PRF in the management of CHA.

  11. Consensually defined facets of personality as prospective predictors of change in depression symptoms.

    Science.gov (United States)

    Naragon-Gainey, Kristin; Watson, David

    2014-08-01

    Depression has robust associations with personality, showing a strong relation with neuroticism and more moderate associations with extraversion and conscientiousness. In addition, each Big Five domain can be decomposed into narrower facets. However, we currently lack consensus as to the contents of Big Five facets, with idiosyncrasies across instruments; moreover, few studies have examined associations with depression. In the current study, community participants completed six omnibus personality inventories; self-reported depressive symptoms were assessed at baseline and 5 years later. Exploratory factor analyses suggested three to five facets in each domain, and these facets served as prospective predictors of depression in hierarchical regressions, after accounting for baseline and trait depression. In these analyses, high anger (from neuroticism), low positive emotionality (extraversion), low conventionality (conscientiousness), and low culture (openness to experiences) were significant prospective predictors of depression. Results are discussed in regard to personality structure and assessment, as well as personality-psychopathology associations. © The Author(s) 2014.

  12. Exploring relations among mindfulness facets and various meditation practices: Do they work in different ways?

    Science.gov (United States)

    Cebolla, Ausiàs; Campos, Daniel; Galiana, Laura; Oliver, Amparo; Tomás, Jose Manuel; Feliu-Soler, Albert; Soler, Joaquim; García-Campayo, Javier; Demarzo, Marcelo; Baños, Rosa María

    2017-03-01

    Several meditation practices are associated with mindfulness-based interventions but little is known about their specific effects on the development of different mindfulness facets. This study aimed to assess the relations among different practice variables, types of meditation, and mindfulness facets. The final sample was composed of 185 participants who completed an on-line survey, including information on the frequency and duration of each meditation practice, lifetime practice, and the Five Facet Mindfulness Questionnaire. A Multiple Indicators Multiple Causes structural model was specified, estimated, and tested. Results showed that the Model's overall fit was adequate: χ 2 (1045)=1542.800 (p<0.001), CFI=0.902, RMSEA=0.042. Results revealed that mindfulness facets were uniquely related to the different variables and types of meditation. Our findings showed the importance of specific practices in promoting mindfulness, compared to compassion and informal practices, and they pointed out which one fits each mindfulness facet better. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Cost Utility Analysis of Cervical Therapeutic Medial Branch Blocks in Managing Chronic Neck Pain.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Pampati, Vidyasagar; Kaye, Alan D; Hirsch, Joshua A

    2017-01-01

    Background: Controlled diagnostic studies have established the prevalence of cervical facet joint pain to range from 36% to 67% based on the criterion standard of ≥ 80% pain relief. Treatment of cervical facet joint pain has been described with Level II evidence of effectiveness for therapeutic facet joint nerve blocks and radiofrequency neurotomy and with no significant evidence for intraarticular injections. However, there have not been any cost effectiveness or cost utility analysis studies performed in managing chronic neck pain with or without headaches with cervical facet joint interventions. Study Design: Cost utility analysis based on the results of a double-blind, randomized, controlled trial of cervical therapeutic medial branch blocks in managing chronic neck pain. Objectives: To assess cost utility of therapeutic cervical medial branch blocks in managing chronic neck pain. Methods: A randomized trial was conducted in a specialty referral private practice interventional pain management center in the United States. This trial assessed the clinical effectiveness of therapeutic cervical medial branch blocks with or without steroids for an established diagnosis of cervical facet joint pain by means of controlled diagnostic blocks. Cost utility analysis was performed with direct payment data for the procedures for a total of 120 patients over a period of 2 years from this trial based on reimbursement rates of 2016. The payment data provided direct procedural costs without inclusion of drug treatments. An additional 40% was added to procedural costs with multiplication of a factor of 1.67 to provide estimated total costs including direct and indirect costs, based on highly regarded surgical literature. Outcome measures included significant improvement defined as at least a 50% improvement with reduction in pain and disability status with a combined 50% or more reduction in pain in Neck Disability Index (NDI) scores. Results: The results showed direct

  14. Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

    Science.gov (United States)

    Mahfoud, Felix; Tunev, Stefan; Ruwart, Jennifer; Schulz-Jander, Daniel; Cremers, Bodo; Linz, Dominik; Zeller, Thomas; Bhatt, Deepak L; Rocha-Singh, Krishna; Böhm, Michael; Melder, Robert J

    2014-12-01

    In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA. We report marked blood pressure reduction after RDN in a patient with resistant hypertension who underwent previous stenting. Subsequently, radiofrequency ablation was investigated within the stented segment of porcine RA, distal to the stented segment, and in nonstented RA and compared with stent only and untreated controls. There were neither observations of thrombus nor gross or histological changes in the kidneys. After radiofrequency ablation of the nonstented RA, sympathetic nerves innervating the kidney were significantly reduced, as indicated by significant decreases in sympathetic terminal axons and reduction of norepinephrine in renal tissue. Similar denervation efficacy was found when RDN was performed distal to a renal stent. In contrast, when radiofrequency ablation was performed within the stented segment of the RA, significant sympathetic nerve ablation was not seen. Histological observation showed favorable healing in all arteries. Radiofrequency ablation of previously stented RA demonstrated that RDN provides equally safe experimental procedural outcomes in a porcine model whether the radiofrequency treatment is delivered within, adjacent, or without the stent struts being present in the RA. However, efficacious RDN is only achieved when radiofrequency ablation is delivered to the nonstented RA segment distal to the stent. © 2014 American Heart Association, Inc.

  15. Pulse-Dose Radiofrequency in Athletic Pubalgia: Preliminary Results.

    Science.gov (United States)

    Masala, Salvatore; Fiori, Roberto; Raguso, Mario; Ojango, Christine; Morini, Marco; Cuzzolino, Alessandro; Calabria, Eros; Simonetti, Giovanni

    2017-05-01

    Chronic pubalgia affects around 10% of athletes. To determine the role of pulse-dose radiofrequency (PDRF) in athletes with chronic pubalgia and investigate the causes with imaging. Prospective nonrandomized single-group study. PDRF was performed on 32 patients with a chronic pain that had been refractory to conservative therapies during the last 3 mo. The genital branches of the genitofemoral, ilioinguinal, and iliohypogastric nerves and the obturator nerve were the goals of treatment. A 10-cm, 20-gauge cannula was inserted with a percutaneous access on the upper and lower edges of the iliopubic branch. After the spindle was removed, a radiofrequency needle with a 10-mm "active tip" was inserted. The radiofrequency technique was performed with 1200 pulses at 45 V and 20-ms duration, followed by a 480-ms silent phase. The follow-up with a clinical examination was performed at 1, 3, 6, and 9 mo after the procedure. During the follow-up visits, the patients were asked to rate their pain on a 0-10 VAS scale. All of the enrolled patients completed the study. Mean VAS score before the treatment was 8.4 ± 0.6. Twenty-four patients had a reduction of pain VAS scores more than 50% during all follow-up visits and started training and physiotherapy in the days after the radiofrequency procedure. Six patients, each treated 2 times, had a reduction more than 50% of VAS scores and could start training and physiotherapy only after the 2nd procedure. One patient had no pain relief with 2 treatments. Pain intensity decreased up to 9 mo in 31 patients (mean VAS scores 3.4 ± 0.5 at 6 mo and 3.8 ± 0.9 at 9 mo). No complications were observed. PDRF is an effective and safe technique in management of chronic pubalgia in athletes.

  16. Perivascular radiofrequency renal denervation lowers blood pressure and ameliorates cardiorenal fibrosis in spontaneously hypertensive rats

    Science.gov (United States)

    Zhang, Yan; Su, Linan; Zhang, Yunrong; Wang, Qiang; Yang, Dachun; Li, De; Yang, Yongjian; Ma, Shuangtao

    2017-01-01

    Background Catheter-based renal denervation (RDN) is a promising approach to treat hypertension, but innervation patterns limit the response to endovascular RDN and the post-procedural renal artery narrowing or stenosis questions the endovascular ablation strategy. This study was performed to investigate the anti-hypertensive and target organ protective effects of perivascular RDN in spontaneously hypertensive rats (SHR). Methods SHR and normotensive Wistar-Kyoto (WKY) rats were divided into sham group (n = 10), radiofrequency ablation group (n = 20) in which rats received bilateral perivascular ablation with radiofrequency energy (2 watts), and chemical (10% phenol in 95% ethanol) ablation group (n = 12). The tail-cuff blood pressure was measured before the ablation and on day 14 and day 28 after the procedure. The plasma levels of creatinine, urea nitrogen, and catecholamines, urinary excretion of electrolytes and protein, and myocardial and glomerular fibrosis were analyzed and compared among the groups on day 28 after the procedure. Results We identified that 2-watt is the optimal radiofrequency power for perivascular RDN in rats. Perivascular radiofrequency and chemical ablation achieved roughly comparable blood pressure reduction in SHR but not in WKY on day 14 and day 28 following the procedure. Radiofrequency-mediated ablation substantially destroyed the renal nerves surrounding the renal arteries of both SHR and WKY without damaging the renal arteries and diminished the expression of tyrosine hydroxylase, the enzyme marker for postganglionic sympathetic nerves. Additionally, perivascular radiofrequency ablation also decreased the plasma catecholamines of SHR. Interestingly, both radiofrequency and chemical ablation decreased the myocardial and glomerular fibrosis of SHR, while neither increased the plasma creatinine and blood urea nitrogen nor affected the urinary excretion of electrolytes and protein when compared to sham group. Conclusions Radiofrequency

  17. Radiofrequency glow discharge time of flight mass spectrometry: pulsed vs. continuous mode

    International Nuclear Information System (INIS)

    Lobo, L.; Pereiro, R.; Sanz-Medel, A.; Bordel, N.; Tempez, A.; Chapon, P.; Hohl, M.; Michler, J.

    2009-01-01

    Full text: Glow discharge (GD) is a well established tool for the direct analysis of solids. The application field of the original direct current GD, restricted to conductive samples, has been extended by radiofrequency powered GDs that can be applied for conductive and non-conductive samples. Moreover, the introduction of pulsed GD has opened the possibility of applying higher instantaneous powers that can improve the atomization-ionization processes and therefore the sensitivity. Furthermore, pulsed-GD may enable temporal separation of discharge gas species from the sample ions. In this work the analytical performances of radiofrequency and pulsed radiofrequency glow discharges are evaluated by using a time of flight mass analyzer (TOFMS). (author)

  18. Radiofrequency fields in our surroundings

    International Nuclear Information System (INIS)

    2011-01-01

    In 2010, the National Radiation Protection Authority (NRPA) with the Post and Telecommunications Authority carried out a project where it is measured radiofrequency fields from various telecom systems in homes, kindergartens, schools, offices, and urban environments. Close to 99 percent of the measurement points were found values of less than one thousandth of the maximum. No values were near the limits. (AG)

  19. Atorvastatin can ameliorate left atrial stunning induced by radiofrequency ablation for atrial fibrillation.

    Science.gov (United States)

    Xie, Ruiqin; Yang, Yingtao; Cui, Wei; Yin, Hongning; Zheng, Hongmei; Zhang, Jidong; You, Ling

    2017-09-01

    The objective of this study was to study the functional changes of the left atrium after radiofrequency ablation treatment for atrial fibrillation and the therapeutic effect of atorvastatin. Fifty-eight patients undergoing radiofrequency ablation for atrial fibrillation were randomly divided into non-atorvastatin group and atorvastatin group. Patients in the atorvastatin group were treated with atorvastatin 20 mg p.o. per night in addition to the conventional treatment of atrial fibrillation; patients in the non-atorvastatin group received conventional treatment of atrial fibrillation only. Echocardiography was performed before radiofrequency ablation operation and 1 week, 2 weeks, 3 weeks, and 4 weeks after operation. Two-dimensional ultrasound speckle tracking imaging system was used to measure the structural indexes of the left atrium. Results indicated that there was no significant change for indexes representing the structural status of the left atrium within a month after radiofrequency ablation (P > 0.05); however, there were significant changes for indexes representing the functional status of the left atrium. There were also significant changes in indexes reflecting left atrial strain status: the S and SRs of atorvastatin group were higher than those of non-atorvastatin group (P atorvastatin could improve left atrial function and shorten the duration of atrial stunning after radiofrequency ablation of atrial fibrillation.

  20. Effects of radiation from a radiofrequency identification (RFID) microchip on human cancer cells.

    Science.gov (United States)

    Lai, Henry C; Chan, Ho Wing; Singh, Narendra P

    2016-01-01

    Radiofrequency identification (RFID) microchips are used to remotely identify objects, e.g. an animal in which a chip is implanted. A passive RFID microchip absorbs energy from an external source and emits a radiofrequency identification signal which is then decoded by a detector. In the present study, we investigated the effect of the radiofrequency energy emitted by a RFID microchip on human cancer cells. Molt-4 leukemia, BT474 breast cancer, and HepG2 hepatic cancer cells were exposed in vitro to RFID microchip-emitted radiofrequency field for 1 h. Cells were counted before and after exposure. Effects of pretreatment with the spin-trap compound N-tert-butyl-alpha-phenylnitrone or the iron-chelator deferoxamine were also investigated. Results We found that the energy effectively killed/retarded the growth of the three different types of cancer cells, and the effect was blocked by the spin-trap compound or the iron-chelator, whereas an inactive microchip and energy from the external source had no significant effect on the cells. Conclusions Data of the present study suggest that radiofrequency field from the microchip affects cancer cells via the Fenton Reaction. Implantation of RFID microchips in tumors may provide a new method for cancer treatment.

  1. Radio-frequency wave enhanced runaway production rate

    International Nuclear Information System (INIS)

    Chan, V.S.; McClain, F.W.

    1983-01-01

    Enhancement of runaway electron production (over that of an Ohmic discharge) can be achieved by the addition of radio-frequency waves. This effect is studied analytically and numerically using a two-dimensional Fokker--Planck quasilinear equation

  2. First muon acceleration using a radio-frequency accelerator

    Directory of Open Access Journals (Sweden)

    S. Bae

    2018-05-01

    Full Text Available Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu^{-}, which are bound states of positive muons (μ^{+} and two electrons, are generated from μ^{+}’s through the electron capture process in an aluminum degrader. The generated Mu^{-}’s are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ. In the RFQ, the Mu^{-}’s are accelerated to 89 keV. The accelerated Mu^{-}’s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

  3. Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

    Energy Technology Data Exchange (ETDEWEB)

    Litos, M.D.; Bionta, M.R.; Dolgashev, V.A.; England, R.J.; Fritz, D.; Gilevich, S.; Hering, Ph.; Hogan, M.J.; /SLAC

    2011-08-19

    Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

  4. Facets of clinicians' anxiety and the delivery of cognitive behavioral therapy.

    Science.gov (United States)

    Levita, Liat; Salas Duhne, Paulina Gonzalez; Girling, Carla; Waller, Glenn

    2016-02-01

    Psychological therapists commonly fail to adhere to treatment protocols in everyday clinical practice. In part, this pattern of drift is attributable to anxious therapists being less likely to undertake some elements of evidence-based therapies - particularly the exposure-based elements. This study considers what facets of anxiety (cognitive, behavioral, physiological) are related to junior clinicians' reported use of cognitive-behavioral therapy techniques. Thirty-two clinicians (mean age = 28.9 years; mean length of CBT experience = 1.5 years; 23 female, nine male) who offered CBT were assessed for their cognitive, behavioral and physiological characteristics (Intolerance of Uncertainty scale; risk taking; skin conductance response and heart rate variability). While the three different facets of anxiety were relatively poorly associated with each other, as is usual in this literature, each facet was linked differently to the reported delivery of CBT techniques (P behavioral or cognitive methods. Of the three facets of anxiety, only physiological reactivity showed an association with the clinicians' temporal characteristics, with more experienced therapists being more likely to have greater skin conductance responses to positive and negative outcomes. These findings suggest that clinicians who are more anxious are less likely to deliver the full evidence-based form of CBT and to focus instead on less challenging elements of the therapy. Potential ways of overcoming this limitation are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Stabilization of the sacroiliac joint.

    Science.gov (United States)

    Shaffrey, Christopher I; Smith, Justin S

    2013-07-01

    Lower back pain and pain involving the area of the posterior iliac spine are extremely common. Degeneration of the sacroiliac joint (SIJ) is one potential cause for lower back pain and pain radiating into the groin or buttocks. Degenerative changes to the lumbar spine and sacroiliac joints are common. A recent study evaluating SIJ abnormalities in a primary low back pain population demonstrated 31.7% of patients demonstrated SI joint abnormalities. (4) As is the case for the evaluation and management of isolated lower back pain, the evaluation, management, and role for surgical intervention in SIJ pain is very controversial. Many patients have degenerative changes of the disc, facet joints, and SIJs. A recent systematic review performed to determine the diagnostic accuracy of tests available to clinicians to identify the disc, facet joint, or SIJ as the source of low back pain concluded that tests do exist that change the probability of the disc or SIJ (but not the facet joint) as the source of low back pain. (3) It was also concluded that the usefulness of these tests in clinical practice, particularly for guiding treatment selection, remains unclear. (3) Although there is general agreement that SIJ pathological changes are a potential cause of pain, there is far less agreement about the optimal management of these conditions. A variety of conditions can cause SIJ dysfunction including degenerative and inflammatory arthritis, trauma, prior lumbosacral fusion, hip arthritis, limb length inequality, infections, and neoplasia. (8) There is increasing evidence that image intensifier-guided single periarticular injection can correctly localize pain to the SIJ but the optimal management strategy remains controversial. Recent publications have compared surgical versus injection treatments and fusion versus denervation procedures. (1 , 8) A systematic review found improvement regardless of the treatment, with most studies reporting over 40% improvement in pain as measured

  6. Mindfulness facets, trait emotional intelligence, emotional distress, and multiple health behaviors: A serial two-mediator model.

    Science.gov (United States)

    Jacobs, Ingo; Wollny, Anna; Sim, Chu-Won; Horsch, Antje

    2016-06-01

    In the present study, we tested a serial mindfulness facets-trait emotional intelligence (TEI)-emotional distress-multiple health behaviors mediation model in a sample of N = 427 German-speaking occupational therapists. The mindfulness facets-TEI-emotional distress section of the mediation model revealed partial mediation for the mindfulness facets Act with awareness (Act/Aware) and Accept without judgment (Accept); inconsistent mediation was found for the Describe facet. The serial two-mediator model included three mediational pathways that may link each of the four mindfulness facets with multiple health behaviors. Eight out of 12 indirect effects reached significance and fully mediated the links between Act/Aware and Describe to multiple health behaviors; partial mediation was found for Accept. The mindfulness facet Observe was most relevant for multiple health behaviors, but its relation was not amenable to mediation. Implications of the findings will be discussed. © 2016 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  7. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results

    International Nuclear Information System (INIS)

    Daniels, M J; Varghese, T; Madsen, E L; Zagzebski, J A

    2007-01-01

    Minimally invasive therapies (such as radiofrequency ablation) are becoming more commonly used in the United States for the treatment of hepatocellular carcinomas and liver metastases. Unfortunately, these procedures suffer from high recurrence rates of hepatocellular carcinoma (∼34-55%) or metastases following ablation therapy. The ability to perform real-time temperature imaging while a patient is undergoing radiofrequency ablation could provide a significant reduction in these recurrence rates. In this paper, we demonstrate the feasibility of ultrasound-based temperature imaging on a tissue-mimicking phantom undergoing radiofrequency heating. Ultrasound echo signals undergo time shifts with increasing temperature, which are tracked using 2D correlation-based speckle tracking methods. Time shifts or displacements in the echo signal are accumulated, and the gradient of these time shifts are related to changes in the temperature of the tissue-mimicking phantom material using a calibration curve generated from experimental data. A tissue-mimicking phantom was developed that can undergo repeated radiofrequency heating procedures. Both sound speed and thermal expansion changes of the tissue-mimicking material were measured experimentally and utilized to generate the calibration curve relating temperature to the displacement gradient. Temperature maps were obtained, and specific regions-of-interest on the temperature maps were compared to invasive temperatures obtained using fiber-optic temperature probes at the same location. Temperature elevation during a radiofrequency ablation procedure on the phantom was successfully tracked to within ±0.5 0 C

  8. International radiofrequency standards

    International Nuclear Information System (INIS)

    Lincoln, J.

    2001-01-01

    Of the various radiofrequency standards in use around the world, many are based on or similar to the Guidelines published by ICNIRP (The International Commission on Non-ionising Radiation Protection). This organisation is a working group operating in co-operation with the Environmental Health division of the World Health Organisation (WHO). This paper presents a very brief overview of current international standards, beginning with a summary of the salient points of the ICNIRP Guidelines. It should be remembered that these are guidelines only and do not exist as a separate standard. Copyright (2001) Australasian Radiation Protection Society Inc

  9. Two-velocity elasticity theory and facet growth

    OpenAIRE

    Andreev, A. F.; Melnikovsky, L. A.

    2002-01-01

    We explain the linear growth of smooth solid helium facets by the presence of lattice point defects. To implement this task, the framework of very general two-velocity elasticity theory equations is developed. Boundary conditions for these equations for various surface types are derived. We also suggest additional experiments to justify the concept.

  10. Management of trigeminal neuralgia by radiofrequency ...

    African Journals Online (AJOL)

    The outcome depends on the type of TN with best results with classical idiopathic type. Also better results occurred with isolated V3 affection. The radiofrequency thermocoagulation of trigeminal nerve is a low risk, highly effective and minimally invasive procedure that should be started with in all cases of TN.

  11. Reliability aspects and facet damage in high-power emission from (AlGa)As cw laser diodes at room temperature

    International Nuclear Information System (INIS)

    Kressel, H.; Ladany, I.

    1975-01-01

    Factors are described that limit the optical power output from (AlGa)As laser diodes (lambda = 8100 to 8300 A) operating cw at room temperature with uncoated facets. Rapid laser ''catastrophic'' degradation due to facet damage (in contrast to ''bulk'' phenomena previously considered) has been found to occur as a result of excessive optical flux density at the facets. The diodes studied are capable of initial cw power emission values of 25 to 100 mW from one facet depending on their dimensions. Data are presented showing long-term constant-current operation at power levels below these maximum values. Preliminary data are also presented on devices utilizing dielectric facet coatings to minimize facet damage. (U.S.)

  12. INTRAOPERATIVE RADIOFREQUENCY AND CRYOABLATION FOR ATRIAL FIBRILLATION IN PATIENTS WITH VALVULAR HEART DISEASE

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaie

    2007-05-01

    Full Text Available Patients with valvular heart disease and suffering atrial fibrillation of more than 12 months duration have a low probability of remaining in sinus rhythm after valve surgery alone. We performed intra-operative radiofrequency ablation or cryoablation as an alternative to surgical maze ІІІ procedure to create linear lesion lines for conversion of this arrhythmia to sinus rhythm. A total of 30 patients with valvular heart disease and chronic persistent atrial fibrillation underwent different combinations of valve surgery and concomitant maze procedure with radiofrequency or cryo probes. These patients aged 48.10 ± 9.84 years in radiofrequency ablation group and 51.10 ± 13.93 years in cryoablation group. Both atrial ablation with radiofrequency probes, needed 26.15 ± 3.67 min extra ischemic time and ablation by mean of cryo-probes needed an extra ischemic time of 29.62 ± 4.27 min. There was one in hospital death postoperatively because of respiratory failure but no other complication. 6 months after the operation, among 30 patients with both atrial ablations, 25 patients were in sinus rhythm, no patient had junctional rhythm and 5 patients had persistent atrial fibrillation. At 12 months follow up, freedom from atrial fibrillation was 85% in radiofrequency group and 80% in cryo group. Doppler echocardiography in these patients demonstrated atrial contractility in 70% of the patients. Intraoperative radiofrequency or cryo-ablation of both atriums are effective and less invasive alternatives for the original maze procedure to eliminate the atrial fibrillation, and can be done in patients with valvular heart disease without increasing the risk of operation.

  13. Ion-storage in radiofrequency electric quadrupole field

    International Nuclear Information System (INIS)

    Gheorghe, V.

    1976-01-01

    The confinement of charged particles in a quadrupole radiofrequency electric field are presented. The stability diagrams and phase space trajectories for the quadrupole mass spectrometer and for the ion trap are represented and their main characteristics are discussed. (author)

  14. Massive hematemesis after radiofrequency ablation of metastatic liver tumor with successful hemostasis achieved through transarterial embolization.

    Science.gov (United States)

    Liu, Chien-An; Chiu, Nai-Chi; Chiou, Yi-You

    2018-03-03

    Hemorrhagic complications are the most common major complications that occur after radiofrequency ablation, but hematemesis as a complication after radiofrequency ablation for hepatic tumor has not been mentioned before. A hepatogastric fistula as a delayed complication is also rare. We present the case of a 77-year-old man with severe hematemesis that occurred 2 months after radiofrequency ablation of a liver metastasis of gastric cancer. A ruptured hepatic artery pseudoaneurysm and a hepatogastric fistula were confirmed through serial imaging examinations. The current case is reported in combination with 2 rare major complications after radiofrequency ablation of a liver tumor. Copyright © 2018. Published by Elsevier Inc.

  15. GPU accelerated Discrete Element Method (DEM) molecular dynamics for conservative, faceted particle simulations

    Energy Technology Data Exchange (ETDEWEB)

    Spellings, Matthew [Chemical Engineering, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Marson, Ryan L. [Materials Science & Engineering, University of Michigan, 2300 Hayward St., Ann Arbor, MI 48109 (United States); Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Anderson, Joshua A. [Chemical Engineering, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Glotzer, Sharon C., E-mail: sglotzer@umich.edu [Chemical Engineering, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States); Materials Science & Engineering, University of Michigan, 2300 Hayward St., Ann Arbor, MI 48109 (United States); Biointerfaces Institute, University of Michigan, 2800 Plymouth Rd., Ann Arbor, MI 48109 (United States)

    2017-04-01

    Faceted shapes, such as polyhedra, are commonly found in systems of nanoscale, colloidal, and granular particles. Many interesting physical phenomena, like crystal nucleation and growth, vacancy motion, and glassy dynamics are challenging to model in these systems because they require detailed dynamical information at the individual particle level. Within the granular materials community the Discrete Element Method has been used extensively to model systems of anisotropic particles under gravity, with friction. We provide an implementation of this method intended for simulation of hard, faceted nanoparticles, with a conservative Weeks–Chandler–Andersen (WCA) interparticle potential, coupled to a thermodynamic ensemble. This method is a natural extension of classical molecular dynamics and enables rigorous thermodynamic calculations for faceted particles.

  16. 21 CFR 880.6300 - Implantable radiofrequency transponder system for patient identification and health information.

    Science.gov (United States)

    2010-04-01

    ... patient identification and health information. 880.6300 Section 880.6300 Food and Drugs FOOD AND DRUG... radiofrequency transponder system for patient identification and health information. (a) Identification. An implantable radiofrequency transponder system for patient identification and health information is a device...

  17. Radio-frequency energy in fusion power generation

    International Nuclear Information System (INIS)

    Lawson, J.Q.; Becraft, W.R.; Hoffman, D.J.

    1983-01-01

    The history of radio-frequency (rf) energy in fusion experiments is reviewed, and the status of current efforts is described. Potential applications to tasks other than plasma heating are described, as are the research and development needs of rf energy technology

  18. Modes of oscillation in radiofrequency Paul traps

    DEFF Research Database (Denmark)

    Landa, H.; Reznik, B.; Drewsen, M.

    2012-01-01

    We examine the time-dependent dynamics of ion crystals in radiofrequency traps. The problem of stable trapping of general threedimensional crystals is considered and the validity of the pseudopotential approximation is discussed. We analytically derive the micromotion amplitude of the ions...

  19. Thermal Protection with 5% Dextrose Solution Blanket During Radiofrequency Ablation

    International Nuclear Information System (INIS)

    Chen, Enn Alexandria; Neeman, Ziv; Lee, Fred T.; Kam, Anthony; Wood, Brad

    2006-01-01

    A serious complication for any thermal radiofrequency ablation is thermal injury to adjacent structures, particularly the bowel, which can result in additional major surgery or death. Several methods using air, gas, fluid, or thermometry to protect adjacent structures from thermal injury have been reported. In the cases presented in this report, 5% dextrose water (D5W) was instilled to prevent injury to the bowel and diaphragm during radiofrequency ablation. Creating an Insulating envelope or moving organs with D5W might reduce risk for complications such as bowel perforation

  20. Exposure of Ontario workers to radiofrequency fields from dielectric heaters

    International Nuclear Information System (INIS)

    Bitran, M.E.; Nishio, J.M.; Charron, D.E.

    1992-01-01

    As part of a program to assess and reduce the exposure of Ontario workers to non-ionizing radiations, stray electric and magnetic fields from 383 dielectric heaters were measured in 71 industrial establishments from 1988 to 1990. This represents a population of over 800 workers potentially exposed to radiofrequency (RE) electromagnetic fields. Electric and magnetic field strengths at the head, waist, and thigh levels of the operators, corrected by duty cycle, are presented for the different heater types surveyed. Worker exposure data and compliance with Ontario radiofrequency exposure guidelines are discussed. (author)

  1. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion.

    Science.gov (United States)

    Ledonio, Charles Gt; Polly, David W; Swiontkowski, Marc F; Cummings, John T

    2014-01-01

    The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS) surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI) outcomes associated with each of these techniques. A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher's exact test and two nonparametric tests, ie, the Mann-Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39-82] years) than the open group (median age 51 [34-74] years). Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44-78]) than in the MIS group (median 53 [14-84]). Postoperative improvement in ODI was statistically significant within and between groups, with MIS resulting in greater improvement. The open and MIS sacroiliac joint fusion techniques resulted in statistically and clinically significant improvement for patients with degenerative sacroiliitis refractory to nonoperative management. However, the number of patients

  2. Radiofrequency/infrared double resonance spectroscopy of the HD+ ion

    International Nuclear Information System (INIS)

    Carrington, Alan; McNab, I.R.; Montgomerie, C.A.

    1989-01-01

    We describe a double resonance technique for obtaining radiofrequency spectra of the HD + ion in vibration-rotation levels close to the dissociation limit. Infrared transitions are driven by Doppler tuning an HD + ion beam into resonance with a carbon dioxide infrared laser, and are detected by measuring H + fragment ions produced by electric field dissociation of the upper vibration-rotation level. Radiofrequency transitions between nuclear hyperfine components of the lower vibration-rotation level are then detected through resonant increases in the H + fragment ion current. The high spectroscopic resolution obtained, and the ability to measure magnetic dipole hyperfine transitions, will enable the hyperfine constants to be determined accurately. (author)

  3. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    olayemitoyin

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed ... mobile phones on autonomic modulation of the heart. ..... Electrocardiogram and Its Technology. J. Am.

  4. [Percutaneous radiofrequency ablation of hepatic metastases. Preliminary experience].

    Science.gov (United States)

    De Baere, T; Elias, D; Ducreux, M; Dromain, C; Kuach, V; Gamal El Din, M; Sobotka, A; Lasser, P; Roche, A

    1999-11-01

    To evaluate the efficiency of percutaneous radiofrequency ablation in the treatment of liver metastases. Eighteen patients with 31 liver metastases, mainly from colorectal cancer, 10 - 35 mm in diameter (m = 23), underwent 26 courses of percutaneous radiofrequency ablation. Fifteen patients had previously undergone hepatectomy, and 3 patients had contra-indications to surgery. Imaging guidance was ultrasound in 21 patients, CT in 4 (tumors not seen with ultrasound), and both in 1. A generator working at 450 KHz with a maximum output power of 150 W was used to treat each lesion for 18 - 20 min. Treatment was monitored with real time ultrasound. Among the 12 patients followed more than 3 months, only one of the 24 treated lesions recurred after a mean follow up of 259 ¿ 109 days. Liver disease was controlled in 8 of the 12 patients after 90 - 509 days (m = 306). Among these 8 patients, 3 were tumor free after 559, 378 and 90 days, respectively; 2 died tumor free of non-tumoral disease (pulmonary embolism, digestive bleeding); 3 developed lung metastases treated with chemotherapy (n = 2) or surgery (n = 1). Three of the 12 patients had widespread hepatic tumor occurrence, and one patient died of these metastases. Six patients experienced mild skin burns, but no major complication was observed. Radiofrequency ablation of hepatic metastases appears safe and promising in this preliminary experience. Further investigation is needed.

  5. [Multi-facetted clinical presentation of thrombotic thrombocytopenic purpura

    DEFF Research Database (Denmark)

    Niemann, C.U.; Jurlander, J.; Daugaard, G.

    2009-01-01

    smears. Determination of the ADAMTS13-activity is now becoming available as a routine analysis. We present two cases that illustrate the multi-facetted clinical presentation under which TTP occurs. The importance of access to ADAMTS13 measurements is stressed Udgivelsesdato: 2009/1/26...

  6. Radiofrequency Coblation Versus Intramural Bipolar Cautery for the Treatment of Inferior Turbinate Hypertrophy.

    Science.gov (United States)

    Shah, Anil N; Brewster, Douglas; Mitzen, Kelly; Mullin, David

    2015-09-01

    Compare intramural bipolar electrocautery and radiofrequency coblation in the treatment of inferior turbinate hypertrophy with regards to objective and subjective improvement in nasal obstruction, rate and type of complications, experience during the procedure, and rate of recovery. Prospective, single-blinded study. Single tertiary medical center from 2008 to 2010. Forty-one adult patients with inferior turbinate hypertrophy refractory to medical management were treated with radiofrequency coblation in one nostril and intramural bipolar cautery in the other. Subjective and objective data, including use of a Visual Analog Scale (VAS) for subjective outcomes, acoustic rhinometry, and nasal endoscopy, were then obtained from each patient comparing the 2 techniques. Radiofrequency coblation was significantly less painful than intramural bipolar cautery during the procedure (P = .03) and during the early postoperative period (P measured by acoustic rhinometry and subjective VAS outcomes. Radiofrequency coblation seems to offer an equivalent alternative to bipolar electrocautery for the treatment of inferior turbinate hypertrophy with less discomfort during the procedure and early post-operative period. © The Author(s) 2015.

  7. Lumbar radiculopathy due to unilateral facet hypertrophy following lumbar disc hernia operation: a case report.

    Science.gov (United States)

    Kökeş, Fatih; Günaydin, Ahmet; Aciduman, Ahmet; Kalan, Mehmet; Koçak, Halit

    2007-10-01

    To present a radiculopathy case due to unilateral facet hypertrophy developing three years after a lumbar disc hernia operation. A fifty two-year-old female patient, who had been operated on for a left L5-S1 herniated lumbar disc three years ago, was hospitalized and re-operated with a diagnosis of unilateral facet hypertrophy. She had complaints of left leg pain and walking restrictions for the last six months. Left Straight Leg Raising test was positive at 40 degrees , left ankle dorsiflexion muscle strength was 4/5, left Extensor Hallucis Longus muscle strength was 3/5, and left Achilles reflex was hypoactive. Lumbar spinal Magnetic Resonance Imaging revealed left L5-S1 facet hypertrophy. Lumbar radiculopathy due to lumbar facet hypertrophy is a well-known neurological condition. Radicular pain develops during the late postoperative period following lumbar disc hernia operations that are often related to recurrent disc herniation or to formation of post-operative scar tissue. In addition, it can be speculated that unilateral facet hypertrophy, which may develop after a disc hernia operation, might also be one of the causes of radiculopathy.

  8. Pulmonary venous thrombosis secondary to radiofrequency ablation of the pulmonary veins

    Directory of Open Access Journals (Sweden)

    Raquel López-Reyes

    Full Text Available Background: Pulmonary Vein Thrombosis (PVT is a rare and underdiagnosed entity produced by local mechanical nature mechanisms, vascular torsion or direct injury to the vein. PVT has been described in clinical cases or small multicenter series mainly in relation to pulmonary vein stenosis, metastatic carcinoma, fibrosing mediastinitis, as an early surgical complication of lung transplantation lobectomy and radiofrequency ablation performed in patients with atrial fibrillation, although in some cases the cause is not known. Case: We report the case of a 57 years old male with history of atrial fibrillation treated by radiofrequency ablation who was admitted in our center because of a two-week history of consistent pleuritic pain in the left hemithorax and low-grade hemoptysis and a lung consolidation treated as a pneumonia with antibiotic but not responding to medical therapy. In view of the poor evolution of the patient, computed tomography angiography was performed with findings of PVT and secondary venous infarction and anticoagulation therapy was optimized. At the end, pulmonary resection was performed due to hemorrhagic recurrence. Conclusion: PVT remains a rare complication of radiofrequency ablation and other procedures involving pulmonary veins. Clinical suspicion and early diagnosis is crucial because is a potentially life-threatening entity. Keywords: Venous thrombosis, Atrial fibrilation, Radiofrequency ablation, Hemoptysis, Lung consolidation, Lung infarction, Lung resection surgery

  9. Lesion size in relation to ablation site during radiofrequency ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A

    1998-01-01

    This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was perfor......This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation...... was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly.......61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased...

  10. MORPHOMETRY OF THE ARTICULAR FACETS ON THE SUPERIOR, MEDIAL AND LATERAL SURFACES OF THE BODY OF TALUS AND ITS CLINICAL RELEVANCE

    Directory of Open Access Journals (Sweden)

    Goda Jatin B, Patel Shailesh M, Parmar Ajay M, Agarwal GC

    2015-07-01

    Full Text Available Background: In the formation of Ankle joint, tibio-fibular mortice receives superior, medial and lateral articular surfaces of body of Talus. Because of very limited availability of the data on the Morphometry of the articular facets on the Body of the dry human tali, this study was undertaken. Aims: To prepare the database on the articular facets on the superior, medial and lateral surfaces of body of talus, to find if there is statistically significant difference between both the sides of measurements and to compare the results with the previous studies. Methods and Material: 40 Dry Human Tali (20 Right and 20 Left were measured with Digital vernier caliper for the following Measurements: On the Trochlear surface: Medial length, Central length, Lateral length, Anterior width, Central width, Posterior width. On the lateral triangular articular facet: Central height, Central width. On the coma shaped medial articular facet: Central height, Central width. Results: Mean values of Medial, Central and Lateral lengths were 31.02, 30.39 and 29.63mm on Right side and 31.79, 30.65 and 29.45mm on Left side. Mean Anterior, Central and Posterior widths were 28.87, 28.16 and 21.59mm on right side and 29.08, 27.54 and 21.78mm on left side. On the medial articular surface, mean central height was 11.93mm on the right side and 11.29mm on the left side, Mean central width was 27.94mm on the right side and 28.29mm on the left side. On the lateral articular surface, mean central height was 22.14mm on the right side and 22.63mm on the left side. Mean central width was 18.93mm on the right side and 18.99mm on the left side. There is no significant difference between right and left sides of measurements. Conclusion: The trochlear articular surface is wider in front, measurements of opposite talus bone can be used as a control during talus bone replacement surgery, it may help surgeons to plan pre-operatively the complex talar fracture surgeries, to design accurate

  11. Radiofrequency and microwave interactions between biomolecular systems

    Czech Academy of Sciences Publication Activity Database

    Kučera, Ondřej; Cifra, Michal

    2016-01-01

    Roč. 42, č. 1 (2016), s. 1-8 ISSN 0092-0606 R&D Projects: GA ČR(CZ) GA15-17102S Institutional support: RVO:67985882 Keywords : Cell signaling * Radiofrequency * Bioelectrodynamics Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.241, year: 2016

  12. Subfracture insult to the human cadaver patellofemoral joint produces occult injury.

    Science.gov (United States)

    Atkinson, P J; Haut, R C

    1995-11-01

    The current criterion used by the automotive industry for injury to the lower extremity is based on visible bone fracture. Studies suggest, however, that chronic joint degeneration may occur after subfracture impact loads on the knee. We hypothesized that subfracture loading of the patellofemoral joint could result in previously undocumented microtrauma in areas of high contact pressure. In the current study, seven patellofemoral joints from human cadavers were subjected to impact with successively greater energy until visible fracture was noted. Transverse and comminuted fractures of the patella were noted at 6.7 kN of load. Approximately 45% of the impact energy then was delivered to the contralateral joint. Subfracture loads of 5.2 kN resulted in no gross bone fracture in five of seven specimens. Histological examination of the patellae horizontal split fracture in the subchondral bone, at the tidemark, or at the interface of calcified cartilage and subchondral bone. The trauma appeared predominantly on the lateral facet, adjacent to or directly beneath preexisting fibrillation of the articular surface. Surface fibrillation was noted in histological sections of control patellae (not subjected to impact loading), but occult damages were not observed. Although the mechanism of this occult trauma is unknown, similar damage has been shown to occur from direct shear loading. As these microcracks can potentiate a disease process in the joint, this study may suggest that the current criterion for injury, based on bone fracture alone, is not sufficiently conservative.

  13. The Biological Effects of Quadripolar Radiofrequency Sequential Application: A Human Experimental Study

    OpenAIRE

    Nicoletti, Giovanni; Cornaglia, Antonia Icaro; Faga, Angela; Scevola, Silvia

    2014-01-01

    Objective: An experimental study was conducted to assess the effectiveness and safety of an innovative quadripolar variable electrode configuration radiofrequency device with objective measurements in an ex vivo and in vivo human experimental model. Background data: Nonablative radiofrequency applications are well-established anti-ageing procedures for cosmetic skin tightening. Methods: The study was performed in two steps: ex vivo and in vivo assessments. In the ex vivo assessments the radio...

  14. Temperature-Controlled Delivery of Radiofrequency Energy in Fecal Incontinence: A Randomized Sham-Controlled Clinical Trial.

    Science.gov (United States)

    Visscher, Arjan P; Lam, Tze J; Meurs-Szojda, Maria M; Felt-Bersma, Richelle J F

    2017-08-01

    Controlled delivery of radiofrequency energy has been suggested as treatment for fecal incontinence. The aim of this study was to determine whether the clinical response to the radiofrequency energy procedure is superior to sham in patients with fecal incontinence. This was a randomized sham-controlled clinical trial from 2008 to 2015. This study was conducted in an outpatient clinic. Forty patients with fecal incontinence in whom maximal conservative management had failed were randomly assigned to receiving either radiofrequency energy or sham procedure. Fecal incontinence was measured using the Vaizey incontinence score (range, 0-24). The impact of fecal incontinence on quality of life was measured by using the fecal incontinence quality-of-life score (range, 1-4). Measurements were performed at baseline and at 6 months. Anorectal function was evaluated using anal manometry and anorectal endosonography at baseline and at 3 months. At baseline, Vaizey incontinence score was 16.8 (SD 2.9). At t = 6 months, the radiofrequency energy group improved by 2.5 points on the Vaizey incontinence score compared with the sham group (13.2 (SD 3.1), 15.6 (SD 3.3), p = 0.02). The fecal incontinence quality-of-life score at t = 6 months was not statistically different. Anorectal function did not show any alteration. Patients with severe fecal incontinence were included in the study, thus making it difficult to generalize the results. Both radiofrequency energy and sham procedure improved the fecal incontinence score, the radiofrequency energy procedure more than sham. Although statistically significant, the clinical impact for most of the patients was negligible. Therefore, the radiofrequency energy procedure should not be recommended for patients with fecal incontinence until patient-related factors associated with treatment success are known. See Video Abstract at http://links.lww.com/DCR/A373.

  15. Longitudinal outcomes of radiofrequency ablation versus surveillance endoscopy for Barrett's esophagus with low-grade dysplasia.

    Science.gov (United States)

    Kahn, A; Al-Qaisi, M; Kommineni, V T; Callaway, J K; Boroff, E S; Burdick, G E; Lam-Himlin, D M; Temkit, M; Vela, M F; Ramirez, F C

    2018-04-01

    Radiofrequency ablation of Barrett's esophagus with low-grade dysplasia is recommended in recent American College of Gastroenterology guidelines, with endoscopic surveillance considered a reasonable alternative. Few studies have directly compared outcomes of radiofrequency ablation to surveillance and those that have are limited by short duration of follow-up. This study aims to compare the long-term effectiveness of radiofrequency ablation versus endoscopic surveillance in a large, longitudinal cohort of patients with Barrett's esophagus, and low-grade dysplasia.We conducted a retrospective analysis of patients with confirmed low-grade dysplasia at a single academic medical center from 1991 to 2014. Patients progressing to high-grade dysplasia or esophageal adenocarcinoma within one year of index LGD endoscopy were defined as missed dysplasia and excluded. Risk factors for progression were assessed via Cox proportional hazards model. Comparison of progression risk was conducted using a Kaplan-Meier analysis. Subset analyses were conducted to examine the effect of reintroducing early progressors and excluding patients diagnosed prior to the advent of ablative therapy. Of 173 total patients, 79 (45.7%) underwent radiofrequency ablation while 94 (54.3%) were untreated, with median follow up of 90 months. Seven (8.9%) patients progressed to high-grade dysplasia or adenocarcinoma despite ablation, compared with 14 (14.9%) undergoing surveillance (P = 0.44). This effect was preserved when patients diagnosed prior to the introduction of radiofrequency ablation were excluded (8.9% vs 13%, P = 0.68). Reintroduction of patients progressing within the first year of follow-up resulted in a trend toward significance for ablation versus surveillance (11.1% vs 23.8%, P = 0.053).In conclusion, progression to high-grade dysplasia or adenocarcinoma was not significantly reduced in the radiofrequency ablation cohort when compared to surveillance. Despite recent studies

  16. The correlation of radiographic findings and patient symptomatology in cervical degenerative joint disease: a cross-sectional study.

    Science.gov (United States)

    Rudy, Iris Sun; Poulos, Alexandra; Owen, Laura; Batters, Ashlee; Kieliszek, Kasia; Willox, Jessica; Jenkins, Hazel

    2015-01-01

    There are few known studies investigating the correlation of symptomatology with the specific subtypes of cervical spine degenerative joint disease demonstrated on radiograph. The aim of this study was to assess the correlation and diagnostic test accuracy of specific symptoms in determining the presence, type and severity of degenerative joint disease on radiograph. A retrospective cross-sectional design was used to correlate cervical radiographic findings with neck pain and related symptomatology. Radiographs of 322 patients from April 2010 to June 2012 were assessed and evidence of radiographic cervical degenerative joint disease was extracted. Clinical data for each patient was obtained from their patient files including: pain using a VAS, presence of neck stiffness, presence of headaches, presence of shoulder referral, presence of hand radiculopathy and presence of hand numbness. Measures of diagnostic test accuracy and regression analysis were used to assess for any correlation between symptoms and radiographic findings. Referral of pain to the shoulder and neck stiffness showed small degrees of correlation with cervical degenerative joint disease, however, these correlations were not maintained when age was accounted for. Only age showed consistent statistical significance as a predictor for degree of disc degeneration (correlation coefficient (95% confidence interval): 0.06 (0.055, 0.066)); the presence of facet hypertrophy (odds ratio (95% confidence interval): 1.12 (1.09, 1.15)); or uncinate process hypertrophy (odds ratio (95% confidence interval): 1.15 (1.12, 1.18)). Neck stiffness demonstrated a small degree of diagnostic test accuracy for the degree of cervical disc degeneration (area under the curve (95%CI): 0.62 (0.56, 0.68)) and the presence of either facet (diagnostic OR (95%CI):1.69 (1.04, 2.76)) and uncinated process hypertrophy (LR+ (95%CI): 1.17 (1.00, 1.38)). The results of this study indicate that clinical symptoms such as pain level

  17. The anterior borders of the clavicle and the acromion are not always aligned in the intact acromioclavicular joint: a cadaveric study.

    Science.gov (United States)

    Barth, Johannes; Boutsiadis, Achilleas; Narbona, Pablo; Lädermann, Alexandre; Arrigoni, Paolo; Adams, Christopher R; Burkhart, Stephen S; Denard, Patrick J

    2017-07-01

    The aim of this study was to find reliable anatomic landmarks of the normal acromioclavicular joint (ACJ) that could enable the precise evaluation of the horizontal displacement of the clavicle after dislocation. The hypothesis was that the anterior borders of the acromion and the clavicle are always aligned in intact ACJs. In 30 cadaveric specimens, the anterior and posterior borders of the ACJ's articular facets and the most prominent anterior and posterior bony landmarks of the acromion and the clavicle were identified. The anterior and posterior overhang of the acromion and the clavicle was measured in relation to the borders of the articular facets. Therefore, the possible anterior and posterior alignment of the ACJ was evaluated. Anteriorly, only 18 ACJs (60%) were aligned whereas 7 (24%) had major overhang of the acromion and 3 (10%) had major overhang of the clavicle. Similarly, 18 cases (60%) were posteriorly aligned, whereas 6 (20%) had major clavicular overhang and 4 (14%) had major overhang of the acromion. In 78% of these cases, the ACJ was aligned as well anteriorly as posteriorly (P < .001). Finally, the larger the width of the acromion (P = .032) or the clavicle (P = .049), the better the posterior joint alignment. Our hypothesis was not verified. The acromion and clavicle are not perfectly aligned in a significant number of specimens with intact ACJs (40% of cases). The most reliable landmarks remain their articular facets. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Randomized Controlled Trial of Minimally Invasive Sacroiliac Joint Fusion Using Triangular Titanium Implants vs Nonsurgical Management for Sacroiliac Joint Dysfunction: 12-Month Outcomes

    Science.gov (United States)

    Polly, David W.; Wine, Kathryn D.; Whang, Peter G.; Frank, Clay J.; Harvey, Charles F.; Lockstadt, Harry; Glaser, John A.; Limoni, Robert P.; Sembrano, Jonathan N.

    2015-01-01

    BACKGROUND: Sacroiliac joint (SIJ) dysfunction is a prevalent cause of chronic, unremitting lower back pain. OBJECTIVE: To concurrently compare outcomes after surgical and nonsurgical treatment for chronic SIJ dysfunction. METHODS: A total of 148 subjects with SIJ dysfunction were randomly assigned to minimally invasive SIJ fusion with triangular titanium implants (n = 102) or nonsurgical management (n = 46). Pain, disability, and quality-of-life scores were collected at baseline and at 1, 3, 6, and 12 months. Success rates were compared using Bayesian methods. Crossover from nonsurgical to surgical care was allowed after the 6-month study visit was complete. RESULTS: Six-month success rates were higher in the surgical group (81.4% vs 26.1%; posterior probability of superiority > 0.9999). Clinically important (≥ 15 point) Oswestry Disability Index improvement at 6 months occurred in 73.3% of the SIJ fusion group vs 13.6% of the nonsurgical management group (P Sacroiliac Fusion Treatment MCS, mental component summary NSM, nonsurgical management ODI, Oswestry Disability Index PCS, physical component summary RFA, radiofrequency ablation SF-36, Short Form-36 SIJ, sacroiliac joint TTO, time trade-off VAS, visual analog scale PMID:26291338

  19. Joint Resource Optimization for Cognitive Sensor Networks with SWIPT-Enabled Relay.

    Science.gov (United States)

    Lu, Weidang; Lin, Yuanrong; Peng, Hong; Nan, Tian; Liu, Xin

    2017-09-13

    Energy-constrained wireless networks, such as wireless sensor networks (WSNs), are usually powered by fixed energy supplies (e.g., batteries), which limits the operation time of networks. Simultaneous wireless information and power transfer (SWIPT) is a promising technique to prolong the lifetime of energy-constrained wireless networks. This paper investigates the performance of an underlay cognitive sensor network (CSN) with SWIPT-enabled relay node. In the CSN, the amplify-and-forward (AF) relay sensor node harvests energy from the ambient radio-frequency (RF) signals using power splitting-based relaying (PSR) protocol. Then, it helps forward the signal of source sensor node (SSN) to the destination sensor node (DSN) by using the harvested energy. We study the joint resource optimization including the transmit power and power splitting ratio to maximize CSN's achievable rate with the constraint that the interference caused by the CSN to the primary users (PUs) is within the permissible threshold. Simulation results show that the performance of our proposed joint resource optimization can be significantly improved.

  20. A New Vacuum Brazing Route for Niobium-316L Stainless Steel Transition Joints for Superconducting RF Cavities

    Science.gov (United States)

    Kumar, Abhay; Ganesh, P.; Kaul, R.; Bhatnagar, V. K.; Yedle, K.; Ram Sankar, P.; Sindal, B. K.; Kumar, K. V. A. N. P. S.; Singh, M. K.; Rai, S. K.; Bose, A.; Veerbhadraiah, T.; Ramteke, S.; Sridhar, R.; Mundra, G.; Joshi, S. C.; Kukreja, L. M.

    2015-02-01

    The paper describes a new approach for vacuum brazing of niobium-316L stainless steel transition joints for application in superconducting radiofrequency cavities. The study exploited good wettability of titanium-activated silver-base brazing alloy (CuSil-ABA®), along with nickel as a diffusion barrier, to suppress brittle Fe-Nb intermetallic formation, which is well reported during the established vacuum brazing practice using pure copper filler. The brazed specimens displayed no brittle intermetallic layers on any of its interfaces, but instead carried well-distributed intermetallic particles in the ductile matrix. The transition joints displayed room temperature tensile and shear strengths of 122-143 MPa and 80-113 MPa, respectively. The joints not only exhibited required hermeticity (helium leak rate high vacuum but also withstood twelve hour degassing heat treatment at 873 K (suppresses Q-disease in niobium cavities), without any noticeable degradation in the microstructure and the hermeticity. The joints retained their leak tightness even after undergoing ten thermal cycles between the room temperature and the liquid nitrogen temperature, thereby establishing their ability to withstand service-induced low cycle fatigue conditions. The study proposes a new lower temperature brazing route to form niobium-316L stainless steel transition joints, with improved microstructural characteristics and acceptable hermeticity and mechanical properties.

  1. Parallel Syndromes: Two Dimensions of Narcissism and the Facets of Psychopathic Personality in Criminally-Involved Individuals

    Science.gov (United States)

    2012-01-01

    Little research has examined different dimensions of narcissism that may parallel psychopathy facets in criminally-involved individuals. The present study examined the pattern of relationships between grandiose and vulnerable narcissism, assessed using the Narcissistic Personality Inventory-16 and the Hypersensitive Narcissism Scale, respectively, and the four facets of psychopathy (interpersonal, affective, lifestyle, and antisocial) assessed via the Psychopathy Checklist: Screening Version (PCL:SV). As predicted, grandiose and vulnerable narcissism showed differential relationships to psychopathy facets, with grandiose narcissism relating positively to the interpersonal facet of psychopathy and vulnerable narcissism relating positively to the lifestyle facet of psychopathy. Paralleling existing psychopathy research, vulnerable narcissism showed stronger associations than grandiose narcissism to 1) other forms of psychopathology, including internalizing and substance use disorders, and 2) self- and other-directed aggression, measured using the Life History of Aggression and the Forms of Aggression Questionnaire. Grandiose narcissism was nonetheless associated with social dysfunction marked by a manipulative and deceitful interpersonal style and unprovoked aggression. Potentially important implications for uncovering etiological pathways and developing treatment interventions for these disorders in externalizing adults are discussed. PMID:22448731

  2. Radiofrequency Ablation in Coccydynia: A Case Series and Comprehensive, Evidence-Based Review.

    Science.gov (United States)

    Chen, Yian; Huang-Lionnet, Julie H Y; Cohen, Steven P

    2017-06-01

    Coccydynia is a condition with a multitude of different causes, characterized by ill-defined management. There are multiple prospective studies, including several controlled trials, that have evaluated conservative therapies. Additionally, a plethora of observational studies have assessed coccygectomy, but few studies have reported results for nonsurgical interventional procedures. In this report, we describe the treatment results of 12 patients who received conventional or pulsed radiofrequency for coccydynia and systematically review the literature on management. We performed a retrospective data analysis evaluating patients who underwent pulsed or conventional radiofrequency treatment at Johns Hopkins Hospital and Walter Reed National Military Medical Center. A comprehensive literature review was also performed to contextualize these results. The mean age of patients treated was 50.25 years (SD = 11.20 years, range = 32-72 years), with the mean duration of symptoms being 3.6 years (SD = 3.36 years, range 1-10 years). There were 10 males and two females in this cohort. Among patients who received radiofrequency treatment, the average benefit was 55.5% pain relief (SD = 30.33%, range = 0-100%). Those who underwent conventional (vs pulsed radiofrequency) and who received prognostic blocks were more likely to experience a positive outcome. There were two cases of neuritis, which resolved spontaneously after several weeks. Radiofrequency ablation of the sacrococcygeal nerves may serve as a useful treatment option for patients with coccydynia who have failed more conservative measures. Further research into this therapeutic approach and its benefit for coccydynia should incorporate a control group for comparison. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  3. {331}-Faceted trisoctahedral gold nanocrystals: synthesis, superior electrocatalytic performance and highly efficient SERS activity

    Science.gov (United States)

    Song, Yahui; Miao, Tingting; Zhang, Peina; Bi, Cuixia; Xia, Haibing; Wang, Dayang; Tao, Xutang

    2015-04-01

    We investigate the effect of gold (Au) seeds prepared in cetyltrimethylammonium chloride solution (CTAC-Au seeds) on the index facets of trisoctahedral gold nanocrystals (TOH Au NCs). We demonstrate that monodisperse {331}-faceted TOH Au NCs with controllable sizes (from 60 to 255 nm) can be successfully prepared in high yield by using 3.0 nm CTAC-Au seeds or as-prepared 70 nm TOH Au NCs as seeds. We find that the electrocatalytic performance on methanol oxidation and surface enhancement Raman spectroscopy (SERS) activity of {331}-faceted TOH Au NCs is size-dependent. In comparison with well-known nanoporous gold (0.088 mA cm-2), {331}-faceted TOH Au NCs with sizes of 110 nm exhibit fairly high catalytic activity (0.178 mA cm-2) on methanol oxidation (1.0 M) in alkaline media due to the presence of increasing density of atomic steps, ledges, and kinks on the NC surfaces. Their current density is reduced by less than 7% after 500 cycling tests. {331}-Faceted TOH Au NCs with sizes of 175 nm exhibit the highest SERS activity for 4-aminothiophenol (4-ATP) molecules. The enhancement factors of a1 modes of 4-ATP molecules can reach the order of 109 when the 4-ATP concentration is 3 × 10-6 M. Moreover, Raman signals (ag modes) of 4,4'-dimercaptoazobenzene (DMAB) molecules on TOH Au NCs are stronger than those on spherical Au NCs of comparable size due to the enhanced laser-induced transformation of 4-ATP molecules by high-index {331}-facets during SERS measurement. Furthermore, the SERS intensities of 4-methylbenzenethiol (4-MTP) molecules on TOH Au NCs are also higher than those on spherical Au NCs of comparable size due to sharp extremities.We investigate the effect of gold (Au) seeds prepared in cetyltrimethylammonium chloride solution (CTAC-Au seeds) on the index facets of trisoctahedral gold nanocrystals (TOH Au NCs). We demonstrate that monodisperse {331}-faceted TOH Au NCs with controllable sizes (from 60 to 255 nm) can be successfully prepared in high yield by

  4. Facet formation and ohmic contacts for laser diodes on non- and semipolar GaN

    Energy Technology Data Exchange (ETDEWEB)

    Rass, Jens; Ploch, Simon; Vogt, Patrick [Technische Universitaet Berlin (Germany). Institute of Solid State Physics; Wernicke, Tim; Redaelli, Luca; Einfeldt, Sven [Ferdinand- Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Kneissl, Michael [Technische Universitaet Berlin (Germany). Institute of Solid State Physics; Ferdinand- Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany)

    2009-07-01

    Group-III-Nitride heterostructures grown on nonpolar and semipolar planes allow the realization of highly efficient devices such as laser diodes and LEDs due to the reduction or elimination of the quantum confined Stark effect. However, the realization of these devices poses a number of challenges, in particular the formation of smooth laser facets and the fabrication of ohmic contacts. In this talk optimized schemes for facet formation and contact resistance reduction for nitride based devices on non- and semipolar planes are presented, and various concepts are discussed. We discuss a laser scribing process that allows the cleaving of facets along the c- and a-plane for devices grown on nonpolar substrates. For semipolar planes there is no low-index cleavage plane in order to form resonators along the projection of the c-axis. Therefore we have investigated etching techniques in order to produce flat facets perpendicular to the plane of growth. For the challenging formation of p-type contacts to GaN we discuss different methods such as chemical treatments, different metallization schemes and capping layers to reduce the contact resistivity.

  5. A Framework for a Multi-Faceted, Educational, Knowledge-Based Recommender System

    Directory of Open Access Journals (Sweden)

    John W. Coffey

    2016-08-01

    Full Text Available The literature on intelligent or adaptive tutoring systems generally has a focus on how to determine what resources to present to students as they make their way through a course of study. The idea of multi-faceted student modeling is that a variety of measures, both academic and non-academic, might be represented in student models in service of a broader educational context. This paper contains a framework for a multi-faceted, educational, knowledge-based recommender system, including a basic set of descriptors that the model contains, and a taxonomy of inferences that might be made over such models.

  6. Selective Facet Reactivity During Cation Exchange in Cadmium Sulfide Nanorods

    Energy Technology Data Exchange (ETDEWEB)

    Sadtler, Bryce; Demchenko, Denis; Zheng, Haimei; Hughes, Steven; Merkle, Maxwell; Dahmen, Ulrich; Wang, Lin-Wang; Alivisatos, A. Paul

    2008-12-18

    The partial transformation of ionic nanocrystals through cation exchange has been used to synthesize nanocrystal heterostructures. We demonstrate that the selectivity for cation exchange to take place at different facets of the nanocrystal plays an important role in determining the resulting morphology of the binary heterostructure. In the case of copper I (Cu+) cation exchange in cadmium sulfide (CdS) nanorods, the reaction starts preferentially at the ends of the nanorods such that copper sulfide (Cu2S) grows inwards from either end. The resulting morphology is very different from the striped pattern obtained in our previous studies of silver I (Ag+) exchange in CdS nanorods where non-selective nucleation of silver sulfide (Ag2S) occurs. From interface formation energies calculated for several models of epitaxialconnections between CdS and Cu2S or Ag2S, we infer the relative stability of each interface during the nucleation and growth of Cu2S or Ag2S within the CdS nanorods. The epitaxial connections of Cu2S to the end facets of CdS nanorods minimize the formation energy, making these interfaces stable throughout the exchange reaction. However, as the two end facets of wurtzite CdS nanorods are crystallographically nonequivalent, asymmetric heterostructures can be produced.

  7. Facet Appearance on the Lateral Face of Sapphire Single-Crystal Fibers during LHPG Growth

    Directory of Open Access Journals (Sweden)

    Liudmila D. Iskhakova

    2016-08-01

    Full Text Available Results of the study of the lateral surface of single-crystal (SC sapphire fibers grown along crystallographic directions [ 0001 ] and [ 11 2 ¯ 0 ] by the LHPG method are presented. The appearance or absence of faceting of the lateral surface of the fibers depending on the growth direction is analyzed. The crystallographic orientation of the facets is investigated. The microstructure of the samples is investigated with the help of an optical microscope and a JSM-5910LV scanning electronic microscope (JEOL. The crystallographic orientations of the facets on the SC sapphire fiber surface are determined by electron backscatter diffraction (EBSD. The seed orientation is studied by means of XRD techniques.

  8. The radiographic distinction of degenerative slippage (spondylolisthesis and retrolisthesis) from traumatic slippage of the cervical spine

    International Nuclear Information System (INIS)

    Lee, C.; Woodring, J.H.; Rogers, L.F.; Kim, K.S.

    1986-01-01

    In a review of 42 cases of degenerative arthritis of the cervical spine and 22 cases of cervical spine trauma with an observed anterior slip-page (spondylolisthesis) or posterior slippage (retrolisthesis) of the vertebral bodies of 2 mm or more, characteristic features were observed which allowed distinction between degenerative and traumatic slippage of the cervical spine. In degenerative slippage the shape of the articular facets and width of the facet joint space may remain normal; however, in most cases the articular facets become 'ground-down' with narrowing of the facet joint space and the articular facets themselves becoming thinned or ribbon-like. In traumatic slippage the articular facets will either be normally shaped or fractured and the facet joint space will be abnormally widened. Plain radiographs will usually allow this distinction to be made; however, in difficult cases polytomography may be required. (orig.)

  9. Within-Trait Heterogeneity in Age Group Differences in Personality Domains and Facets: Implications for the Development and Coherence of Personality Traits

    Science.gov (United States)

    Mõttus, René; Realo, Anu; Allik, Jüri; Esko, Tõnu; Metspalu, Andres; Johnson, Wendy

    2015-01-01

    The study investigated differences in the Five-Factor Model (FFM) domains and facets across adulthood. The main questions were whether personality scales reflected coherent units of trait development and thereby coherent personality traits more generally. These questions were addressed by testing if the components of the trait scales (items for facet scales and facets for domain scales) showed consistent age group differences. For this, measurement invariance (MI) framework was used. In a sample of 2,711 Estonians who had completed the NEO Personality Inventory 3 (NEO PI-3), more than half of the facet scales and one domain scale did not meet the criterion for weak MI (factor loading equality) across 12 age groups spanning ages from 18 to 91 years. Furthermore, none of the facet and domain scales met the criterion for strong MI (intercept equality), suggesting that items of the same facets and facets of the same domains varied in age group differences. When items were residualized for their respective facets, 46% of them had significant (p traits should show similar age group differences. Given this, the FFM domains and facets as embodied in the NEO PI-3 do not reflect aetiologically coherent traits. PMID:25751273

  10. FACET, Radiation View Factor with Shadowing

    International Nuclear Information System (INIS)

    Shapiro, A.B.

    1988-01-01

    1 - Description of program or function: FACET calculates the radiation geometric view factor (alternatively called shape factor, angle factor, or configuration factor) between surfaces for axisymmetric, two-dimensional planar and three-dimensional geometries with interposed third surface obstructions. FACET was developed to calculate view factors as input data to finite element heat transfer analysis codes. 2 - Method of solution: Three algorithms are incorporated to integrate the view factor equation for three dimensional geometries. The algorithm used for any two surfaces depends on their geometric relationship and whether third surface obstructions exist. The three algorithms are the area integration (AI) method, the line integration method (LI), and the Mitalas and Stephenson (MS) method. The LI method is used to calculate the view factor between two disjoint surfaces. If the two surfaces have an adjoint edge, the MS method is used. The AI method is used if there is self or third surface shadowing. In two-dimensional planar geometries, the view factor between two surfaces is calculated using Hottel's cross string method. For axisymmetric geometries in the absence of shadowing, the view factor between two surfaces is calculated by view factor algebra using the view factors between parallel coaxial discs. In the presence of self or third surface shadowing, the geometry is represented in three dimensions before calculating the view factors

  11. Differentiating Between Donald Trump and Hillary Clinton Voters Using Facets of Right-Wing Authoritarianism and Social-Dominance Orientation.

    Science.gov (United States)

    Crowson, Howard Michael; Brandes, Joyce A

    2017-06-01

    Historically, much of the research on right-wing authoritarianism and social dominance orientation has proceeded from the assumption that they are unidimensional. Recently, researchers have begun to seriously consider the possibility that they are multidimensional in nature and should be measured as such. Several studies have examined the unique relationships between right-wing authoritarianism and social dominance orientation facets and social and political outcome measures of interest. However, there have been no efforts to include the full slate of right-wing authoritarianism and social dominance orientation facets as predictors in the same model. This is problematic when investigating the discriminant validity of these facets, given the potential empirical overlap among the facets both within and across scales. We included facets of right-wing authoritarianism and social dominance orientation as predictors of U.S. voters' intentions to vote for Hillary Clinton versus Donald Trump in the 2016 Presidential Election. Data were collected in September 2016. We found evidence for the discriminant validity of several of the right-wing authoritarianism and social dominance orientation facets.

  12. Pulsed radiofrequency on radial nerve under ultrasound guidance for treatment of intractable lateral epicondylitis.

    Science.gov (United States)

    Oh, Dae Seok; Kang, Tae Hyung; Kim, Hyae Jin

    2016-06-01

    Lateral epicondylitis is a painful and functionally limiting disorder. Although lateral elbow pain is generally self-limiting, in a minority of people symptoms persist for a long time. When various conservative treatments fail, surgical approach is recommended. Surgical denervation of several nerves that innervate the lateral humeral epicondyle could be considered in patients with refractory pain because it denervates the region of pain. Pulsed radiofrequency is a minimally invasive procedure that improves chronic pain when applied to various neural tissues without causing any significant destruction and painful complication. This procedure is safe, minimally invasive, and has less risk of complications relatively compared to the surgical approach. The radial nerve can be identified as a target for pulsed radiofrequency lesioning in lateral epicondylitis. This innovative method of pulsed radiofrequency applied to the radial nerve has not been reported before. We reported on two patients with intractable lateral epicondylitis suffering from elbow pain who did not respond to nonoperative treatments, but in whom the ultrasound-guided pulsed radiofrequency neuromodulation of the radial nerve induced symptom improvement. After a successful diagnostic nerve block, radiofrequency probe adjustment around the radial nerve was performed on the lateral aspect of the distal upper arm under ultrasound guidance and multiple pulsed treatments were applied. A significant reduction in pain was reported over the follow-up period of 12 weeks.

  13. Characterization of etch pits found on a large-grain bulk niobium superconducting radio-frequency resonant cavity

    Science.gov (United States)

    Zhao, Xin; Ciovati, G.; Bieler, T. R.

    2010-12-01

    The performance of superconducting radio-frequency (SRF) resonant cavities made of bulk niobium is limited by nonlinear localized effects. Surface analysis of regions of higher power dissipation is thus of intense interest. Such areas (referred to as “hotspots”) were identified in a large-grain single-cell cavity that had been buffered-chemical polished and dissected for examination by high resolution electron microscopy, electron backscattered diffraction microscopy (EBSD), and optical microscopy. Pits with clearly discernible crystal facets were observed in both “hotspot” and “coldspot” specimens. The pits were found in-grain, at bicrystal boundaries, and on tricrystal junctions. They are interpreted as etch pits induced by crystal defects (e.g. dislocations). All coldspots examined had a qualitatively lower density of etch pits or relatively smooth tricrystal boundary junctions. EBSD mapping revealed the crystal orientation surrounding the pits. Locations with high pit density are correlated with higher mean values of the local average misorientation angle distributions, indicating a higher geometrically necessary dislocation content. In addition, a survey of the samples by energy dispersive x-ray analysis did not show any significant contamination of the samples’ surface. The local magnetic field enhancement produced by the sharp-edge features observed on the samples is not sufficient to explain the observed degradation of the cavity quality factor, which starts at peak surface magnetic field as low as 20 mT.

  14. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, J; Low, D [University of California, Los Angeles, Los Angeles, CA (United States); Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J [ViewRay, Inc., Oakwood Village, OH (United States)

    2016-06-15

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  15. TU-H-BRA-01: The Physics of High Power Radiofrequency Isolation in a Novel Compact Linear Accelerator Based MRI Guided Radiation Therapy System

    International Nuclear Information System (INIS)

    Lamb, J; Low, D; Mutic, S; Shvartsman, S; Chmielewski, T; Fought, G; Sharma, A; Dempsey, J

    2016-01-01

    Purpose: To develop a method for isolating the radiofrequency waves emanating from linear accelerator components from the magnetic resonance imaging (MRI) system of an integrated MRI-linac. Methods: An MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. The radiofrequency waves created by the accelerating process would degrade MR image quality, so a method for containing the radiofrequency waves and isolating the MR imager from them was developed. The linear accelerator radiofrequency modulator was placed outside the room, so a filter was designed to eliminate the radiofrequency corresponding to the proton Larmour frequency of 14.7 MHz. Placing the radiofrequency emitting components in a typical Faraday cage would have reduced the radiofrequency emissions, but the design would be susceptible to small gaps in the shield due to the efficiency of the Faraday cage reflecting internal radiofrequency emissions. To reduce internal radiofrequency reflections, the Faraday cage was lined with carbon fiber sheets. Carbon fiber has the property of attenuating the radiofrequency energy so that the overall radiofrequency field inside the Faraday cage is reduced, decreasing any radiofrequency energy emitted from small gaps in the cage walls. Results: Within a 1.2 MHz band centered on the Larmor frequency, the radiofrequency (RF) leakage from the Faraday cage was measured to be −90 dB with no RF on, −40 dB with the RF on and no shield, returning to −90 dB with the RF on and shields in place. The radiofrequency filter attenuated the linear accelerator modulator emissions in the 14.7 MHz band by 70 dB. Conclusions: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of isolating the high power RF system from the MRI, has been solved. The measured radiofrequency emissions are sufficiently small to enable system integration. This research was

  16. Evaluation of microneedling fractional radiofrequency device for treatment of acne scars

    Directory of Open Access Journals (Sweden)

    Byalekere Shivanna Chandrashekar

    2014-01-01

    Full Text Available Background: Various treatment modalities including non-invasive methods such as chemical peels, topical retinoids, microdermabrasion, minimally invasive techniques such as microneedling, fractional lasers, microneedling radiofrequency devices and invasive procedures such as acne scar surgeries and ablative lasers are used for acne scars, each with its own unique advantages and disadvantages. This study is a retrospective assessment of efficacy and safety of microneedling fractional radiofrequency in the treatment of acne scars. Methods: Thirty one patients of skin types III-V with moderate and severe facial acne scarring received four sequential fractional radiofrequency treatments over a period of 6 months with an interval of 6 weeks between each session. Goodman & Baron′s acne scar grading system was used for assessment by a side by side comparison of preoperative and post- operative photographs taken at their first visit and at the end of 3 months after the last session. Results: Estimation of improvement with Goodman and Baron′s Global Acne Scarring System showed that by qualitative assessment of 31 patients with grade 3 and grade 4 acne scars, 80.64% showed improvement by 2 grades and 19.35% showed improvement by 1 grade. Quantitative assessment showed that 58% of the patients had moderate, 29% had minimal, 9% had good and 3% showed very good improvement. Adverse effects were limited to transient pain, erythema, edema and hyperpigmentation. Conclusion: Microneedling fractional radiofrequency is efficacious for the treatment of moderate and severe acne scars.

  17. Novel high-resolution temperature probe for radiofrequency dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Schuderer, Juergen [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland); Schmid, Thomas [Schmid and Partner Engineering AG, 8004 Zurich (Switzerland); Urban, Gerald [IMTEK, Albert-Ludwigs University Freiburg, 79110 Freiburg (Germany); Samaras, Theodoros [Department of Physics, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kuster, Niels [Foundation for Research on Information Technologies in Society (IT' IS), Integrated Systems Laboratory IIS, Swiss Federal Institute of Technology (ETH), CH-8092 Zurich (Switzerland)

    2004-03-21

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 {mu}m x 100 {mu}m layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 {mu}m from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  18. Novel high-resolution temperature probe for radiofrequency dosimetry

    International Nuclear Information System (INIS)

    Schuderer, Juergen; Schmid, Thomas; Urban, Gerald; Samaras, Theodoros; Kuster, Niels

    2004-01-01

    A novel integrated thermistor probe for temperature evaluations in radiofrequency-heated environments was realized. The probe's sensitive area is based on a highly resistive 50 μm x 100 μm layer of amorphous germanium processed on a glass tip. The small dimensions allow measurements with a distance as close as 150 μm from solid boundaries. Due to its high temperature resolution of 4 mK and its short response time of the order of 10 ms, the sensor is very well suited for dosimetric measurements in strong absorption gradients. The influence of radiofrequency (RF) electric fields on the signal is minimized due to the high resistance of the sensor and the leads. The probe was successfully used to determine the highly nonuniform absorption distribution resulting from the RF exposure of cell cultures placed in Petri dishes. (note)

  19. A glimpse behind the mask: facets of narcissism and feelings of self-worth.

    Science.gov (United States)

    Zeigler-Hill, Virgil; Besser, Avi

    2013-01-01

    This study examined the connections that the facets of narcissism captured by the Narcissistic Personality Inventory (NPI; Raskin & Hall, 1979) and the Pathological Narcissism Inventory (PNI; Pincus et al., 2009) have with self-esteem. This was accomplished by asking 372 participants to complete measures of narcissism and self-esteem level as well as daily diary measures concerning their state self-esteem and daily experiences. Our analyses found that the facets of narcissism differed in their associations with average level of self-esteem, fluctuations in state self-esteem over time, and self-esteem reactions following daily events. These results suggest that it is important to consider specific facets of narcissism when examining feelings of self-worth rather than relying on broader composite measures of narcissistic personality features. Implications of these results for our understanding of the dynamics of the narcissistic personality are discussed.

  20. Facets of operational performance in an emergency room (ER)

    NARCIS (Netherlands)

    van der Vaart, Taco; Vastag, Gyula; Wijngaard, Jacob

    This paper, using detailed time measurements of patients complemented by interviews with hospital management and staff, examines three facets of an emergency room's (ER) operational performance: (1) effectiveness of the triage system in rationing patient treatment; (2) factors influencing ER's

  1. Potential health risks due to telecommunications radiofrequency ...

    African Journals Online (AJOL)

    Background: The global system mobile telecommunications system (GSM) which was recently introduced in Nigeria is now being used by over 40 million people in Nigeria. The use of GSM is accompanied with exposure of the users to radiofrequency radiation (RFR), which if significant, may produce health hazards. This is ...

  2. Synthesis of ZnWO{sub 4} Electrode with tailored facets: Deactivating the Microorganisms through Photoelectrocatalytic methods

    Energy Technology Data Exchange (ETDEWEB)

    Zhan, Su [Department of Materials Science and Engineering, Dalian Maritime University, Dalian 116026 (China); Zhou, Feng, E-mail: zhoufeng99@mails.tsinghua.edu.cn [Department of Materials Science and Engineering, Dalian Maritime University, Dalian 116026 (China); Huang, Naibao; Liu, Yujun; He, Qiuchen; Tian, Yu; Yang, Yifan [Department of Materials Science and Engineering, Dalian Maritime University, Dalian 116026 (China); Ye, Fei [Department of Materials Science and Engineering, Dalian University of Technology, Dalian 116026 (China)

    2017-01-01

    Highlights: • ZnWO{sub 4} with different exposed facets was synthesized by the hydrothermal method. • The reactive facets were tailored by varying the solution pH. • The photoelectrocatalysis was more efficient in deactivating the microorganism. - Abstract: The exotic invasive species from the ballast water in the ship will bring about serious damages to ecosystem. Photocatalyst films have been widely studied for sterilization. In this study, ZnWO{sub 4} with different exposed facets was synthesized by hydrothermal method, and ZnWO{sub 4} film electrodes have been applied in ballast water treatment through the electro-assisted photocatalytic system. Then the samples were investigated by X-ray diffraction (XRD), X-ray photo-electron spectroscopy (XPS), Field emission on scanning electron microcopy (FE-SEM), Transmission electron microscopy (TEM), UV–vis diffuse reflectance spectroscopy (DRS), BET specific surface area analysis, Fourier transform infrared (FT-IR) and Electrochemical impedance spectra (EIS). ZnWO{sub 4} with an appropriate exposure of (0 1 1) facets ratio exhibited the best photocatalytic and photoelectrocatalytic activities. The microorganisms deactivated completely in 10 min by ZnWO{sub 4} films with 3 V bias. The mechanisms of (0 1 1) facets enhanced the photocatalytic and photoelectrocatalytic activities which were deduced based on the calculated result from the first principles. Simultaneously, appropriate exposed facets and applied bias could reduce the recombination of the photogenerated electron-hole pairs, and improve the photocatalytic activities of ZnWO{sub 4}.

  3. Hierarchical (0 0 1) facet anatase/rutile TiO2 heterojunction photoanode with enhanced photoelectrocatalytic performance

    International Nuclear Information System (INIS)

    Tian, Hongyi; Zhao, Guohua; Zhang, Ya-nan; Wang, Yanbin; Cao, Tongcheng

    2013-01-01

    Highlights: ► (0 0 1) facet TiO 2 photoanode with large surface area is reported for the first time. ► Ordered heterojunction further improves light absorption in (0 0 1) facet TiO 2 system. ► (0 0 1) facet TiO 2 photoanode possesses promoted photoelectrocatalytic performance. ► Photoelectrical enhancement mechanism is clarified by electrochemical methods. ► Photogenerated carrier and lifetime are remarkably enhanced by ingenious design. -- Abstract: A hierarchical heterojunction TiO 2 photoanode with large surface/body ratio is reported to exhibit high oxidation activity due to the constructing of anatase TiO 2 with exposed (0 0 1) facets. The mixed-phase photoanode is fabricated through surfactant-assisted anchoring ultrathin anatase nanosheets on vertically ordered rutile nanorod arrays. This cactaceae-like TiO 2 possesses high-exposed (0 0 1) facets outer layer, large specific surface area (375 m 2 g −1 ), efficient photo-to-current conversion (8.2%) and excellent photocatalytic ability to degrade bisphenol A. The greatly promoted photoelectric and photocatalytic performance results from the synergetic effects of the architecture design of high-active (0 0 1) facets and hierarchical heterojunctions. The mechanism analysis reveals that the remarkable increase of photogenerated carrier concentration (2.40 × 10 22 cm −3 ) improves photocatalytic activity, by virtue of constructing staggered energy levels, suppressing the recombination of electrons and holes, and extending the electron lifetime (133 ms)

  4. The Role of Surface Passivation in Controlling Ge Nanowire Faceting.

    Science.gov (United States)

    Gamalski, A D; Tersoff, J; Kodambaka, S; Zakharov, D N; Ross, F M; Stach, E A

    2015-12-09

    In situ transmission electron microscopy observations of nanowire morphologies indicate that during Au-catalyzed Ge nanowire growth, Ge facets can rapidly form along the nanowire sidewalls when the source gas (here, digermane) flux is decreased or the temperature is increased. This sidewall faceting is accompanied by continuous catalyst loss as Au diffuses from the droplet to the wire surface. We suggest that high digermane flux and low temperatures promote effective surface passivation of Ge nanowires with H or other digermane fragments inhibiting diffusion and attachment of Au and Ge on the sidewalls. These results illustrate the essential roles of the precursor gas and substrate temperature in maintaining nanowire sidewall passivation, necessary to ensure the growth of straight, untapered, ⟨111⟩-oriented nanowires.

  5. Investigation on CO catalytic oxidation reaction kinetics of faceted perovskite nanostructures loaded with Pt

    KAUST Repository

    Yin, S. M.

    2017-01-18

    Perovskite lead titanate nanostructures with specific {111}, {100} and {001} facets exposed, have been employed as supports to investigate the crystal facet effect on the growth and CO catalytic activity of Pt nanoparticles. The size, distribution and surface chemical states of Pt on the perovskite supports have been significantly modified, leading to a tailored conversion temperature and catalytic kinetics towards CO catalytic oxidation.

  6. Investigation on CO catalytic oxidation reaction kinetics of faceted perovskite nanostructures loaded with Pt

    KAUST Repository

    Yin, S. M.; Duanmu, J. J.; Zhu, Yihan; Yuan, Y. F.; Guo, S. Y.; Yang, J. L.; Ren, Z. H.; Han, G. R.

    2017-01-01

    Perovskite lead titanate nanostructures with specific {111}, {100} and {001} facets exposed, have been employed as supports to investigate the crystal facet effect on the growth and CO catalytic activity of Pt nanoparticles. The size, distribution and surface chemical states of Pt on the perovskite supports have been significantly modified, leading to a tailored conversion temperature and catalytic kinetics towards CO catalytic oxidation.

  7. Non-exponential decoherence of radio-frequency resonance rotation of spin in storage rings

    Science.gov (United States)

    Saleev, A.; Nikolaev, N. N.; Rathmann, F.; Hinder, F.; Pretz, J.; Rosenthal, M.

    2017-08-01

    Precision experiments, such as the search for electric dipole moments of charged particles using radio-frequency spin rotators in storage rings, demand for maintaining the exact spin resonance condition for several thousand seconds. Synchrotron oscillations in the stored beam modulate the spin tune of off-central particles, moving it off the perfect resonance condition set for central particles on the reference orbit. Here, we report an analytic description of how synchrotron oscillations lead to non-exponential decoherence of the radio-frequency resonance driven up-down spin rotations. This non-exponential decoherence is shown to be accompanied by a nontrivial walk of the spin phase. We also comment on sensitivity of the decoherence rate to the harmonics of the radio-frequency spin rotator and a possibility to check predictions of decoherence-free magic energies.

  8. Intentions to Cheat: Ajzen's Planned Behavior and Goal-Related Personality Facets.

    Science.gov (United States)

    Lonsdale, Damian

    2017-02-17

    This study sought to test antecedents to college students' intentions to cheat by utilizing Ajzen's ( 1991 ) theory of planned behavior (TPB), and four goal-related personality facets. Those facets were behavioral approach, behavioral inhibition, need for achievement-hope of success, and need for achievement-fear of failure. As hypothesized, perceived friends' and parents' attitudes toward academic dishonesty (two subjective norms) and perceived ease of cheating (perceived behavioral control) all positively predicted overall intentions to cheat. Perceived friends' attitudes seemed to play a more influential role than perceived parents' attitudes. Interestingly, male students reported greater parental acceptance of academic misconduct than female students reported. Among the personality facets, behavioral approach and need for achievement-hope of success were positive and negative predictors of cheating intentions, respectively. A more fine-grained examination of take-home assignments revealed that students considered them easier to cheat on and reported greater intentions to cheat on them in comparison to other forms of academic work (e.g., exams and papers). Also, need for achievement-fear of failure positively predicted intentions to cheat on take-home assignments, but not other cheating intentions. Implications and suggestions for future research are discussed.

  9. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    Science.gov (United States)

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  10. Solvothermal synthesis of TiO{sub 2} nanocrystals with {001} facets using titanic acid nanobelts for superior photocatalytic activity

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yuhui; Zong, Lanlan [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Li, Qiuye, E-mail: qiuyeli@henu.edu.cn [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China); Li, Chen; Li, Junli [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Yang, Jianjun, E-mail: yangjianjun@henu.edu.cn [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China)

    2017-01-01

    Highlights: • TiO{sub 2} exposed with {001} facets were firstly prepared using TAN as Ti source. • The mineralization rate of MO on sample with 77% {001} facets was as high as 96%. • The superior photocatalytic activity was greatly due to {001} facets exposing. - Abstract: Anatase TiO{sub 2} nanocrystals exposed with {001} facets were fabricated by solvothermal strategy in HF-C{sub 4}H{sub 9}OH mixed solution, using titanic acid nanobelts (TAN) as a precursor. The shape of TAN is a long flat plane with a high aspect ratio, and F{sup −} is easily adsorbed on the surface of the nanobelts, inducing a higher exposure of {001} facet of TiO{sub 2} nanoparticles during the structure reorganization. The exposed percentage of {001} facets could vary from 40 to 77% by adjusting the amount of HF. The as-prepared samples were characterized by transmission electron microscopy, N{sub 2} adsorption-desorption isotherms, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscope. The photocatalytic measurement showed that TiO{sub 2} nanocrystals with 77% {001} facets exhibited much superior photocatalytic activity for photodegradation of methyl orange, methylene blue, and rhodamine B. And what’s more, the mineralization rate of methyl orange was as high as 96% within 60 min. The photocatalytic enhancement is due to a large amount of the high energetic {001} facets exposing, the special truncated octahedral morphology and a stronger ability for dyes adsorption.

  11. Contemporary cybernetics and its facets of cognitive informatics and computational intelligence.

    Science.gov (United States)

    Wang, Yingxu; Kinsner, Witold; Zhang, Du

    2009-08-01

    This paper explores the architecture, theoretical foundations, and paradigms of contemporary cybernetics from perspectives of cognitive informatics (CI) and computational intelligence. The modern domain and the hierarchical behavioral model of cybernetics are elaborated at the imperative, autonomic, and cognitive layers. The CI facet of cybernetics is presented, which explains how the brain may be mimicked in cybernetics via CI and neural informatics. The computational intelligence facet is described with a generic intelligence model of cybernetics. The compatibility between natural and cybernetic intelligence is analyzed. A coherent framework of contemporary cybernetics is presented toward the development of transdisciplinary theories and applications in cybernetics, CI, and computational intelligence.

  12. Phase measuring deflectometry. An improved setup for measuring CTA mirror facets

    Energy Technology Data Exchange (ETDEWEB)

    Specovius, Andreas; Eldik, Christopher van; Woernlein, Andre; Ziegler, Alexander [Erlangen Centre for Astroparticle Physics (ECAP) (Germany)

    2016-07-01

    The future Cherenkov Telescope Array (CTA) will consist of up to 100 single telescopes with a total reflecting surface of ∝10.000 m{sup 2} made of numerous mirror facets. Characterizing the surface properties of these facets is quite challenging concerning time and logistics. An efficient way to reliably reconstruct the surface of specular free-forms is Phase Measuring Deflectometry (PMD). PMD is routinely used to characterize the focal distance and point spread function of spherical CTA prototype mirrors. To address the possibility to measure the surface properties of aspherical mirrors, a new PMD setup has recently been built. First experience with this setup is reported.

  13. Spontaneous resolution of symptoms associated with a facet synovial cyst in an adult female – a case report

    Science.gov (United States)

    Ngo, Trung; Decina, Philip; Hsu, William

    2013-01-01

    Background: Facet cysts are implicated in neural compression in the lumbar spine. Surgery is the definitive treatment for symptomatic facet cysts since the failure rate for conservative treatment is quite high; however, the role of physical/manual medicine practitioners in the management of symptomatic facet cysts has not been well explored. This case report will add to the body of evidence of spontaneous resolution of symptoms associated with facet cysts in the chiropractic literature. Case: A 58 year old female presented with acute low back and right leg pain which she attributed to a series of exercise classes that involved frequent foot stomping. Physical examination did not elicit any objective evidence of radiculopathy but MRI and CT scans revealed a facet cyst impinging on the right L5 nerve root. Injections and surgery were recommended; however, the patient’s radicular symptoms completely resolved after three months without surgical intervention. Summary: There is currently a paucity of data in the literature regarding the chiropractor’s role in the management of symptomatic facet cysts. The case presented here has added to this literature and possible areas for future research have been explored. PMID:23483069

  14. Fabrication of etched facets and vertical couplers in InP for packaging and on-wafer test

    NARCIS (Netherlands)

    Lemos Alvares Dos Santos, Rui; D'Agostino, D.; Soares, F. M.; Haghighi, H. Rabbani; Williams, K. A.; Leijtens, X. J. M.

    2016-01-01

    In this letter, the fabrication and the characterization of angled and straight etched facets in InP-based technology are reported. In addition, we report on etched facets combined with coupler mirrors for vertical outcoupling, realized with a wet-etching process.

  15. Facile Synthesis of Gold Nanorice Enclosed by High- Index Facets and Its Application for CO Oxidation

    International Nuclear Information System (INIS)

    Zheng, Y.; Tao, J.; Liu, H.; Zeng, J.; Yu, T.; Ma, Y.; Moran, C.; Wu, L.; Zhu, Y.; Liu, J.; Xia, Y.

    2011-01-01

    A facile method for generating Au nanorice enclosed by high-index facets in high purity. The nanorice shows much higher catalytic activity for CO oxidation than multiply twinned particles of Au enclosed by {111} facets at temperatures below 300 C.

  16. The role of PET/CT in evaluation of Facet and Disc abnormalities in patients with low back pain using 18Fluorine

    International Nuclear Information System (INIS)

    Gamie, S.; El-Maghraby, T.

    2008-01-01

    Bone scintigraphy including Single Photon Emission Computed Tomography (SPECT) is known for its role in the diagnosis of low back pain disorders. Positron Emission Tomography (PET) with 18 Fluoride) as a tracer can be used to carry out bone scans with improved image quality. With the addition of CT, simultaneous PET/CT fused images provide more accurate anatomical details. The objectives of this work are E VCT 64-Slice combined scanner. Imaging started 45-60 minutes after administration of 12-15 mCi (444-55 MBq) of 18 F-Fluoride. The PET scan was acquired from the skull base through the inguinal region in 3D mode at 2 minutes/bed. A low resolution, non-contrast CT scan was also acquired for anatomic localization and attenuation correction. The 18 F-PET/CT showed abnormal uptake in the spine in 56 patients, with an overall detection ability of 84%. Facet joints as a cause of back pain was much more frequent (25 with abnormal scans). One-third (36%) of the patients showed multiple positive uptake in both facet joints and disc areas (20/56). The patients were further divided into two groups. Group A consisted of 42 patients (63%) with back pain and no previous operative procedures, and the 18 F-PET/CT showed a high sensitivity (88%) in identifying the source of pain in 37/42 patients. Group B included 25 patients (37%) with prior lumbar fusion or laminectomy, in which the PET/CT showed positive uptake in 76% (19/25 patients). 18 F-PET/CT showed positive uptake in all patients (100%) with a history of pain after lumbar fusion, while in the laminectomy subgroup only 11 cases (65%) showed positive focal uptake. 18 FPET-CT has potential use in evaluating adult patients with back pain. It has a promising role in identifying causes of persistent back pain following vertebral surgical interventions. (authors)

  17. Efficacy of inferior turbinoplasty with the use of CO(2) laser, radiofrequency, and electrocautery.

    Science.gov (United States)

    Prokopakis, Emmanuel P; Koudounarakis, Eleftherios I; Velegrakis, George A

    2014-01-01

    Inferior turbinate surgery is one of the most commonly performed methods for the treatment of rhinitis symptoms, especially nasal obstruction. This is a comparative study of CO2 laser, electrocautery, and radiofrequency turbinoplasty in the treatment of rhinitis symptoms. From 1994 to 2011, 3219 patients were enrolled in the study. Two hundred eighty-three patients were lost during follow-.up. Of the remaining 2936 patients, 1066 were managed using the CO2 laser, whereas 664 and 1206 were managed with the use of radiofrequency and electrocautery, respectively. All procedures were performed under local anesthesia. Patients were asked to evaluate their symptoms with the visual analog scale (VAS) preoperatively, as well as 1 month and 1 year postoperatively. Rhinomanometry was used to objectively evaluate the effect on nasal obstruction. Mean VAS values preoperatively, regarding nasal obstruction, were 7.43 ± 0.96, 7.33 ± 0.87, and 7.64 ± 0.95 in the CO2 laser, radiofrequency, and electrocautery group, respectively. One month postoperatively, the score was significantly improved in all groups (CO2 laser, 3.44 ± 0.99; radiofrequency, 3.26 ± 0.76; electrocautery, 3.19 ± 0.79), which was almost stable in the 1st year of follow-up. Similar results were also observed in the evaluation of sneezing and rhinorrhea. Outcome did not statistically differ between the three methods. The CO2 laser, radiofrequency and electrocautery offer excellent postoperative results in turbinoplasty cases under local anesthesia.

  18. Use of Radiofrequency Ablation in Benign Thyroid Nodules: A Literature Review and Updates

    OpenAIRE

    Wong, KP; Lang, HHB

    2013-01-01

    Successful thermal ablation using radiofrequency has been reported in various tumors including liver or kidney tumors. Nonsurgical minimally invasive ablative therapy such as radiofrequency ablation (RFA) has been reported to be a safe and efficient treatment option in managing symptomatic cold thyroid nodules or hyperfunctioning thyroid nodules. Pressure and cosmetic symptoms have been shown to be significantly improved both in the short and long terms after RFA. For hyperfunctioning thyroid...

  19. Length of Barrett's segment predicts failure of eradication in radiofrequency ablation for Barrett's esophagus: a retrospective cohort study.

    Science.gov (United States)

    Luckett, Tyler; Allamneni, Chaitanya; Cowley, Kevin; Eick, John; Gullick, Allison; Peter, Shajan

    2018-05-21

    We aim to investigate factors that may contribute to failure of eradication of dysplastic Barrett's Esophagus among patients undergoing radiofrequency ablation treatment. A retrospective review of patients undergoing radiofrequency ablation for treatment of Barrett's Esophagus was performed. Data analyzed included patient demographics, medical history, length of Barrett's Esophagus, number of radiofrequency ablation sessions, and histopathology. Subsets of patients achieving complete eradication were compared with those not achieving complete eradication. A total of 107 patients underwent radiofrequency ablation for Barrett's Esophagus, the majority white, overweight, and male. Before treatment, 63 patients had low-grade dysplasia, and 44 patients had high-grade dysplasia or carcinoma. Complete eradication was achieved in a majority of patients (57% for metaplasia, and 76.6% for dysplasia). Failure of eradication occurred in 15.7% of patients. The median number of radiofrequency ablation treatments in patients achieving complete eradication was 3 sessions, compared to 4 sessions for failure of eradication (p = 0.06). Barrett's esophagus length of more than 5 cm was predictive of failure of eradication (p Radiofrequency ablation for dysplastic Barrett's Esophagus is a proven and effective treatment modality, associated with a high rate of complete eradication. Our rates of eradication from a center starting an ablation program are comparable to previously published studies. Length of Barrett's segment > 5 cm was found to be predictive of failure of eradication in patients undergoing radiofrequency ablation.

  20. Treatment of Décolletage Photoaging With Fractional Microneedling Radiofrequency.

    Science.gov (United States)

    Lyons, Alexis; Roy, Jillian; Herrmann, Jennifer; Chipps, Lisa

    2018-01-01

    The objective of this study was to examine the efficacy and safety of a novel fractional microneedling radiofrequency device to improve the appearance of rhytides and skin laxity of the décolletage. Twelve subjects received a total of three fractional microneedling radiofrequency treatments with Endymed Intensif (EndyMed Ltd., Cesarea, Israel) at least three weeks apart. Primary outcome measure was clinical efficacy quantified by a patient survey to assess treatment satisfaction as well as a physician Global Aesthetic Improvement Scale (GAIS). Photos were taken before every treatment and at a follow-up appointment. Assessments by two board-certified dermatologists revealed an overall improvement in 67% of patients. Seventy percent of subjects rated their post-treatment skin laxity and rhytides as improved, while 60% of patients rated their skin texture as improved. Eighty percent of subjects were at least slightly satisfied with their treatment. Forty percent of subjects would recommend this treatment to others. Subjects in this study demonstrated an overall improvement in décolletage appearance in regard to skin tightening, wrinkles, and skin texture suggested by overall patient satisfaction (80%) and physician-rated GAIS improvement (67%). This study suggests that fractional microneedling radiofrequency devices are a safe and efficacious way to improve overall décolletage appearance with little down time. J Drugs Dermatol. 2018;17(1):74-76..

  1. Radiofrequency radiation

    International Nuclear Information System (INIS)

    Elder, J.A.; Czerski, P.A.; Stuchly, M.A.; Mild, K.H.; Sheppard, A.R.

    1989-01-01

    High-level radiofrequency radiation is a source of thermal energy that carries all of the known implications of heating for biological systems, including burns, temporary and permanent changes in reproduction, cataracts, and death. In general, no changes in chromosomes, DNA or the reproductive potential of animals exposed to RF radiation have been reported in the absence of significant rises in temperature, though there are limited data on DNA and chromosomal changes at non-thermal levels. Human data are currently limited and do not provide adequate information about the relationship between prolonged low-level RF radiation exposure and increased mortality or morbidity, including cancer incidence. In epidemiological studies and clinical reports of RF effects in man, the problems of quantification are numerous and include uncertainties about ''dose'', health effects, latent periods, dose-response relationships, and interactions with other physical or chemical agents. 228 refs, 6 figs, 2 tabs

  2. Mitral valve perforation appearing years after radiofrequency ablation

    DEFF Research Database (Denmark)

    Fisch-Thomsen, Marie; Jensen, Jesper K; Egeblad, Henrik

    2011-01-01

    The case is reported of a young adult with Wolff-Parkinson-White (WPW) syndrome who, three years after a complicated radiofrequency (RF) catheter ablation procedure, developed dyspnea on exertion. Echocardiography revealed severe mitral valve regurgitation caused by a perforation of the posterior...

  3. Radiofrequency solutions in clinical high field magnetic resonance

    NARCIS (Netherlands)

    Andreychenko, A.

    2013-01-01

    Magnetic resonance imaging (MRI) and spectroscopy (MRS) benefit from the sensitivity gain at high field (≥7T). However, high field brings also certain challenges associated with growing frequency and spectral dispersion. Frequency growth results in degraded performance of large volume radiofrequency

  4. Endovascular ultrasound for renal sympathetic denervation in patients with therapy-resistant hypertension not responding to radiofrequency renal sympathetic denervation.

    Science.gov (United States)

    Stiermaier, Thomas; Okon, Thomas; Fengler, Karl; Mueller, Ulrike; Hoellriegel, Robert; Schuler, Gerhard; Desch, Steffen; Lurz, Philipp

    2016-06-12

    Recent studies have reported a considerable number of non-responders after renal sympathetic de-nervation (RSD) with radiofrequency technology. Here we report our results of repeat RSD using ultrasound in these patients. A cohort study was performed in patients who underwent ultrasound RSD after non-response to RSD with radiofrequency. Non-response was defined as mean daytime systolic blood pressure ≥140 mmHg and/or a reduction of ≤10 mmHg in ambulatory blood pressure measurement (ABPM) ≥6 months after radiofrequency denervation. ABPM was recorded at baseline, post radiofrequency RSD as well as at three and six months post ultrasound RSD. A total of 24 non-responders underwent retreatment with the ultrasound device at a mean 15.3±8.2 months after radiofrequency RSD. Ultrasound RSD was performed successfully in all patients without severe adverse events. Mean daytime systolic blood pressure changed from 161.7±14.6 mmHg at baseline to 158.5±9.5 mmHg post radiofrequency RSD and to 150.5±10.4 mmHg and 151.6±11.0 mmHg at three and six months, respectively, post ultrasound RSD (pmeasures analysis of variance). The main results of post hoc testing were as follows: baseline versus post radiofrequency RSD, p=0.83; baseline versus three months post ultrasound RSD, p=0.01; and baseline versus six months post ultrasound RSD, p=0.04. Ultrasound RSD appears to be safe and an effective therapeutic approach in patients not responding to previous RSD with radiofrequency technology.

  5. Complications associated with radiofrequency ablation of pulmonary veins.

    Science.gov (United States)

    Madrid Pérez, J M; García Barquín, P M; Villanueva Marcos, A J; García Bolao, J I; Bastarrika Alemañ, G

    Radiofrequency ablation is an efficacious alternative in patients with symptomatic atrial fibrillation who do not respond to or are intolerant to at least one class I or class III antiarrhythmic drug. Although radiofrequency ablation is a safe procedure, complications can occur. Depending on the location, these complications can be classified into those that affect the pulmonary veins themselves, cardiac complications, extracardiac intrathoracic complications, remote complications, and those that result from vascular access. The most common complications are hematomas, arteriovenous fistulas, and pseudoaneurysms at the puncture site. Some complications are benign and transient, such as gastroparesis or diaphragmatic elevation, whereas others are potentially fatal, such as cardiac tamponade. Radiologists must be familiar with the complications that can occur secondary to pulmonary vein ablation to ensure early diagnosis and treatment. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Obtaining Content Weights for Test Specifications from Job Analysis Task Surveys: An Application of the Many-Facets Rasch Model

    Science.gov (United States)

    Wang, Ning; Stahl, John

    2012-01-01

    This article discusses the use of the Many-Facets Rasch Model, via the FACETS computer program (Linacre, 2006a), to scale job/practice analysis survey data as well as to combine multiple rating scales into single composite weights representing the tasks' relative importance. Results from the Many-Facets Rasch Model are compared with those…

  7. Comparative effectiveness of open versus minimally invasive sacroiliac joint fusion

    Directory of Open Access Journals (Sweden)

    Ledonio CGT

    2014-06-01

    Full Text Available Charles GT Ledonio,1 David W Polly Jr,1 Marc F Swiontkowski,1 John T Cummings Jr2 1Department of Orthopaedic Surgery, University of Minnesota, Twin Cities, MN, 2Community Neurosurgical Care, Indianapolis, IN, USA Background: The mainstay of sacroiliac joint disruption/degenerative sacroiliitis therapy has been nonoperative management. This nonoperative management often includes a regimen of physical therapy, chiropractic treatment, therapeutic injections, and possibly radiofrequency ablation at the discretion of the treating physician. When these clinical treatments fail, sacroiliac joint fusion has been recommended as the standard treatment. Open and minimally invasive (MIS surgical techniques are typical procedures. This study aims to compare the perioperative measures and Oswestry Disability Index (ODI outcomes associated with each of these techniques. Methods: A comparative retrospective chart review of patients with sacroiliac joint fusion and a minimum of 1 year of follow-up was performed. Perioperative measures and ODI scores were compared using the Fisher's exact test and two nonparametric tests, ie, the Mann–Whitney U test and the Wilcoxon signed-rank test. The results are presented as percent or median with range, as appropriate. Results: Forty-nine patients from two institutions underwent sacroiliac joint fusion between 2006 and 2012. Ten patients were excluded because of incomplete data, leaving 39 evaluable patients, of whom 22 underwent open and 17 underwent MIS sacroiliac joint fusion. The MIS group was significantly older (median age 66 [39–82] years than the open group (median age 51 [34–74] years. Surgical time and hospital stay were significantly shorter in the MIS group than in the open group. Preoperative ODI was significantly greater in the open group (median 64 [44–78] than in the MIS group (median 53 [14–84]. Postoperative improvement in ODI was statistically significant within and between groups, with MIS

  8. Within-trait heterogeneity in age group differences in personality domains and facets: implications for the development and coherence of personality traits.

    Science.gov (United States)

    Mõttus, René; Realo, Anu; Allik, Jüri; Esko, Tõnu; Metspalu, Andres; Johnson, Wendy

    2015-01-01

    The study investigated differences in the Five-Factor Model (FFM) domains and facets across adulthood. The main questions were whether personality scales reflected coherent units of trait development and thereby coherent personality traits more generally. These questions were addressed by testing if the components of the trait scales (items for facet scales and facets for domain scales) showed consistent age group differences. For this, measurement invariance (MI) framework was used. In a sample of 2,711 Estonians who had completed the NEO Personality Inventory 3 (NEO PI-3), more than half of the facet scales and one domain scale did not meet the criterion for weak MI (factor loading equality) across 12 age groups spanning ages from 18 to 91 years. Furthermore, none of the facet and domain scales met the criterion for strong MI (intercept equality), suggesting that items of the same facets and facets of the same domains varied in age group differences. When items were residualized for their respective facets, 46% of them had significant (p < 0.0002) residual age-correlations. When facets were residualized for their domain scores, a majority had significant (p < 0.002) residual age-correlations. For each domain, a series of latent factors were specified using random quarters of their items: scores of such latent factors varied notably (within domains) in correlations with age. We argue that manifestations of aetiologically coherent traits should show similar age group differences. Given this, the FFM domains and facets as embodied in the NEO PI-3 do not reflect aetiologically coherent traits.

  9. Personality Facets and RIASEC Interests: An Integrated Model

    Science.gov (United States)

    Armstrong, Patrick Ian; Anthoney, Sarah Fetter

    2009-01-01

    Research examining links between personality and interest have typically focused on links between measures of the five factor model and Holland's RIASEC types. However, the five factor model of personality can be divided in to a larger set of narrow domain personality scales measuring facets of the "big five" traits. Research in a number of fields…

  10. A note on clique-web facets for multicut polytopes

    DEFF Research Database (Denmark)

    Sørensen, Michael Malmros

    2002-01-01

    In this note we provide a previously undiscovered necessary condition for the facet-defining property of clique-web inequalities for the multicut polytope. This condition imposes a minimum cardinality requirement on the node set of the clique, thus implying, in general, that clique-web inequaliti...

  11. A hybrid polarization-selective atomic sensor for radio-frequency field detection with a passive resonant-cavity field amplifier

    OpenAIRE

    Anderson, David A.; Paradis, Eric G.; Raithel, Georg

    2018-01-01

    We present a hybrid atomic sensor that realizes radio-frequency electric field detection with intrinsic field amplification and polarization selectivity for robust high-sensitivity field measurement. The hybrid sensor incorporates a passive resonator element integrated with an atomic vapor cell that provides amplification and polarization selectivity for detection of incident radio-frequency fields. The amplified intra-cavity radio-frequency field is measured by atoms using a quantum-optical ...

  12. Diagnostic accuracy of low-dose versus ultra-low-dose CT for lumbar disc disease and facet joint osteoarthritis in patients with low back pain with MRI correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sun Hwa [Inje University College of Medicine, Department of Emergency Medicine, Sanggye Paik Hospital, Nowon-gu (Korea, Republic of); Yun, Seong Jong; Jo, Hyeon Hwan; Kim, Dong Hyeon [Republic of Korea Air Force, Department of Radiology, Aerospace Medical Center, Cheongwon-gun, Chungcheongbuk-do (Korea, Republic of); Song, Jae Gwang [Republic of Korea Air Force, Department of Orthopedic Surgery, Aerospace Medical Center, Cheongwon-gun, Chungcheongbuk-do (Korea, Republic of); Park, Yong Sung [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2018-04-15

    To compare the image quality, radiation dose, and diagnostic performance between low-dose (LD) and ultra-low-dose (ULD) lumbar-spine (L-spine) CT with iterative reconstruction (IR) for patients with chronic low back pain (LBP). In total, 260 patients with chronic LBP who underwent L-spine CT between November 2015 and September 2016 were prospectively enrolled. Of these, 143 underwent LD-CT with IR and 117 underwent ULD-CT with IR. The patients were divided according to their body mass index (BMI) into BMI1 (<22.9 kg/m{sup 2}), BMI2 (23.0-24.9 kg/m{sup 2}), and BMI3 (≥25 kg/m{sup 2}) groups. Two blinded radiologists independently evaluated the signal-to-noise ratio (SNR), qualitative image quality, and final diagnoses (lumbar disc disease and facet joint osteoarthritis). L-spine MRIs interpreted by consensus were used as the reference standard. All data were statistically analyzed. ULD protocol showed significantly lower SNR for all patients (p < 0.001) except the vertebral bodies and lower qualitative image quality for BMI3 patients (p ≤ 0.033). There was no statistically significant difference between ULD (sensitivity, 95.1-98.1%; specificity, 92.5-98.7%; accuracy, 94.6-98.0%) and LD protocols (sensitivity, 95.6-100%; specificity, 95.5-98.9%; accuracy, 97.4-98.1%), (all p≥0.1) in the BMI1 and BMI2; while dose was 60-68% lower with the ULD protocol. Interobserver agreements were excellent or good with regard to image quality and final diagnoses. For the BM1 and BMI2 groups, ULD-CT provided an acceptable image quality and exhibited a diagnostic accuracy similar to that of LD-CT. These findings suggest that it is a useful diagnostic tool for patients with chronic LBP who exhibit a BMI of <25 kg/m{sup 2}. (orig.)

  13. Diagnostic accuracy of low-dose versus ultra-low-dose CT for lumbar disc disease and facet joint osteoarthritis in patients with low back pain with MRI correlation

    International Nuclear Information System (INIS)

    Lee, Sun Hwa; Yun, Seong Jong; Jo, Hyeon Hwan; Kim, Dong Hyeon; Song, Jae Gwang; Park, Yong Sung

    2018-01-01

    To compare the image quality, radiation dose, and diagnostic performance between low-dose (LD) and ultra-low-dose (ULD) lumbar-spine (L-spine) CT with iterative reconstruction (IR) for patients with chronic low back pain (LBP). In total, 260 patients with chronic LBP who underwent L-spine CT between November 2015 and September 2016 were prospectively enrolled. Of these, 143 underwent LD-CT with IR and 117 underwent ULD-CT with IR. The patients were divided according to their body mass index (BMI) into BMI1 (<22.9 kg/m 2 ), BMI2 (23.0-24.9 kg/m 2 ), and BMI3 (≥25 kg/m 2 ) groups. Two blinded radiologists independently evaluated the signal-to-noise ratio (SNR), qualitative image quality, and final diagnoses (lumbar disc disease and facet joint osteoarthritis). L-spine MRIs interpreted by consensus were used as the reference standard. All data were statistically analyzed. ULD protocol showed significantly lower SNR for all patients (p < 0.001) except the vertebral bodies and lower qualitative image quality for BMI3 patients (p ≤ 0.033). There was no statistically significant difference between ULD (sensitivity, 95.1-98.1%; specificity, 92.5-98.7%; accuracy, 94.6-98.0%) and LD protocols (sensitivity, 95.6-100%; specificity, 95.5-98.9%; accuracy, 97.4-98.1%), (all p≥0.1) in the BMI1 and BMI2; while dose was 60-68% lower with the ULD protocol. Interobserver agreements were excellent or good with regard to image quality and final diagnoses. For the BM1 and BMI2 groups, ULD-CT provided an acceptable image quality and exhibited a diagnostic accuracy similar to that of LD-CT. These findings suggest that it is a useful diagnostic tool for patients with chronic LBP who exhibit a BMI of <25 kg/m 2 . (orig.)

  14. Personality and externalizing behavior in the transition to young adulthood: the additive value of personality facets.

    Science.gov (United States)

    Klimstra, Theo A; Luyckx, Koen; Hale Iii, William W; Goossens, Luc

    2014-08-01

    The directionality of effects in the associations between personality and externalizing behavior (i.e., delinquency, soft drugs use, and alcohol abuse) is unclear. Moreover, previous studies only examined personality trait domains when examining these associations, whereas personality facets underlying these broad domains provide more specificity. To address these limitations, the present study examined the directionality of effects between externalizing behavior and personality while employing a facet-level approach to personality. Cross-lagged panel models were employed to four annual measurement waves of longitudinal data on 485 Belgian-Caucasian late adolescents (87.4 % female; M age = 18.63 years, SD = 0.61). Participants filled out the NEO-FFI as a measure of personality, the Deviant Behavior Scale as a measure of delinquency, and single items for soft drugs use and alcohol abuse on all four measurement occasions. The incremental value of personality facets over broad trait domains was demonstrated, as it was often the case that only some, but not all, facets underlying a specific trait domain were significantly associated with specific externalizing behaviors. Furthermore, linkages between personality and externalizing behavior were shown to be complex. Depending on the personality trait domain or facet and the specific behavior under investigation, the directionality of effects may differ. To capture the full complexity of the linkages between personality and externalizing behavior, a facet approach to personality is recommended. This information is potentially important for clinicians, as it indicates which specific aspects of a broad trait domain affect, and are affected by, specific externalizing behaviors.

  15. CW operation of high-power blue laser diodes with polished facets on semi-polar ( 20 2 ¯ 1 ¯ ) GaN substrates

    KAUST Repository

    Pourhashemi, A.

    2016-10-11

    Continuous wave (CW) operation of high-power blue laser diodes (LDs) with polished facets on semi-polar (202̅1̅) gallium nitride (GaN) substrates is demonstrated. Ridge waveguide LDs were fabricated using indium GaN waveguiding layers and GaN cladding layers. At a lasing wavelength of 452 nm, the peak two-facet CW output power from an LD with uncoated facets was 1.71 W at a current of 3 A, corresponding to an optical power density of 32.04 MW/cm2 on each facet. The dependence of output power on current did not change with repeated CW measurements, indicating that the polished facets did not degrade under high-power CW operation. These results show that polished facets are a viable alternative to cleaved or etched facets for high-power CW semi-polar LDs.

  16. CW operation of high-power blue laser diodes with polished facets on semi-polar ( 20 2 ¯ 1 ¯ ) GaN substrates

    KAUST Repository

    Pourhashemi, A.; Farrell, R.M.; Cohen, D.A.; Becerra, D.L.; DenBaars, S.P.; Nakamura, S.

    2016-01-01

    Continuous wave (CW) operation of high-power blue laser diodes (LDs) with polished facets on semi-polar (202̅1̅) gallium nitride (GaN) substrates is demonstrated. Ridge waveguide LDs were fabricated using indium GaN waveguiding layers and GaN cladding layers. At a lasing wavelength of 452 nm, the peak two-facet CW output power from an LD with uncoated facets was 1.71 W at a current of 3 A, corresponding to an optical power density of 32.04 MW/cm2 on each facet. The dependence of output power on current did not change with repeated CW measurements, indicating that the polished facets did not degrade under high-power CW operation. These results show that polished facets are a viable alternative to cleaved or etched facets for high-power CW semi-polar LDs.

  17. Utilization and growth patterns of sacroiliac joint injections from 2000 to 2011 in the medicare population.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Hansen, Hans; Pampati, Vidyasagar; Falco, Frank J E

    2013-01-01

      The high prevalence of persistent low back pain and growing number of diagnostic and therapeutic modalities employed to manage chronic low back pain and the subsequent impact on society and the economy continue to hold sway over health care policy. Among the multiple causes responsible for chronic low back pain, the contributions of the sacroiliac joint have been a subject of debate albeit a paucity of research. At present, there are no definitive conservative, interventional or surgical management options for managing sacroiliac joint pain. It has been shown that the increases were highest for facet joint interventions and sacroiliac joint blocks with an increase of 310% per 100,000 Medicare beneficiaries from 2000 to 2011. There has not been a systematic assessment of the utilization and growth patterns of sacroiliac joint injections. Analysis of the growth patterns of sacroiliac joint injections in Medicare beneficiaries from 2000 to 2011. To evaluate the utilization and growth patterns of sacroiliac joint injections. This assessment was performed utilizing Centers for Medicare and Medicaid Services (CMS) Physician/Supplier Procedure Summary (PSPS) Master data from 2000 to 2011. The findings of this assessment in Medicare beneficiaries from 2000 to 2011 showed a 331% increase per 100,000 Medicare beneficiaries with an annual increase of 14.2%, compared to an increase in the Medicare population of 23% or annual increase of 1.9%. The number of procedures increased from 49,554 in 2000 to 252,654 in 2011, or a rate of 125 to 539 per 100,000 Medicare beneficiaries. Among the various specialists performing sacroiliac joint injections, physicians specializing in physical medicine and rehabilitation have shown the most increase, followed by neurology with 1,568% and 698%, even though many physicians from both specialties have been enrolling in interventional pain management and pain management. Even though the numbers were small for nonphysician providers including

  18. Final Report for Project "Framework Application for Core-Edge Transport Simulations (FACETS)"

    Energy Technology Data Exchange (ETDEWEB)

    Estep, Donald [Colorado State Univ., Fort Collins, CO (United States)

    2014-01-17

    This is the final report for the Colorado State University Component of the FACETS Project. FACETS was focused on the development of a multiphysics, parallel framework application that could provide the capability to enable whole-device fusion reactor modeling and, in the process, the development of the modeling infrastructure and computational understanding needed for ITER. It was intended that FACETS be highly flexible, through the use of modern computational methods, including component technology and object oriented design, to facilitate switching from one model to another for a given aspect of the physics, and making it possible to use simplified models for rapid turnaround or high-fidelity models that will take advantage of the largest supercomputer hardware. FACETS was designed in a heterogeneous parallel context, where different parts of the application can take advantage through parallelism based on task farming, domain decomposition, and/or pipelining as needed and applicable. As with all fusion simulations, an integral part of the FACETS project was treatment of the coupling of different physical processes at different scales interacting closely. A primary example for the FACETS project is the coupling of existing core and edge simulations, with the transport and wall interactions described by reduced models. However, core and edge simulations themselves involve significant coupling of different processes with large scale differences. Numerical treatment of coupling is impacted by a number of factors including, scale differences, form of information transferred between processes, implementation of solvers for different codes, and high performance computing concerns. Operator decomposition involving the computation of the individual processes individually using appropriate simulation codes and then linking/synchronizing the component simulations at regular points in space and time, is the defacto approach to high performance simulation of multiphysics

  19. Endoscopic release of congenital muscular torticollis with radiofrequency in teenagers.

    Science.gov (United States)

    Wang, Jun-Liang; Qi, Wei; Liu, Yu-Jie

    2018-05-03

    Congenital muscular torticollis (CMT) is due to contracture of the sternocleidomastoid muscle which may cause activity limitations of the neck, tilt of the head, craniofacial asymmetry, and deformity of the skull. The authors present their experience of arthroscopic tight fibrous band release with radiofrequency in teenagers under local anesthesia and evaluate the clinical results. A total of 69 patients who underwent arthroscopic release of CMT with radiofrequency under local anesthesia by a single surgeon could participate in this study. Before operation, surface landmarks of sternocleidomastoid muscle, bone, and neurovascular structures were marked. Local infiltrating anesthesia of the surgical region was then performed. Through a working space created by blunt dissection, the arthroscopy and radiofrequency devices were introduced. Then, the clavicular and sternal heads of the sternocleidomastoid muscle were identified and gradually transected. The patients were followed up postoperatively with Cheng's scoring system. There were 31 male patients and 38 female patients. The mean age of the patients was 16.1 years. The mean length of follow-up in this series was 36.7 months (range, 28 to 67 months). During the operation, 62 patients (89.9%) had no pain, 6 patients (8.7%) felt mild pain, and only 1 patient (1.4%) regarded the procedure as very painful. At all follow-up periods, there were no repeat arthroscopies for any of these patients. At the final follow-up, the average rotation deficit improved from 22.5° to 4.1° postoperatively, and the average lateral bending deficit improved from 14.6° to 3.3° (p radiofrequency under local anesthesia provides surgeons with an alternative to traditional open techniques for the management of congenital muscular torticollis (CMT). Our date shows that this method is minimally invasive and provides good functional recovery with a lower risk of complications.

  20. Measurement of intrahepatic pressure during radiofrequency ablation in porcine liver.

    Science.gov (United States)

    Kawamoto, Chiaki; Yamauchi, Atsushi; Baba, Yoko; Kaneko, Keiko; Yakabi, Koji

    2010-04-01

    To identify the most effective procedures to avoid increased intrahepatic pressure during radiofrequency ablation, we evaluated different ablation methods. Laparotomy was performed in 19 pigs. Intrahepatic pressure was monitored using an invasive blood pressure monitor. Radiofrequency ablation was performed as follows: single-step standard ablation; single-step at 30 W; single-step at 70 W; 4-step at 30 W; 8-step at 30 W; 8-step at 70 W; and cooled-tip. The array was fully deployed in single-step methods. In the multi-step methods, the array was gradually deployed in four or eight steps. With the cooled-tip, ablation was performed by increasing output by 10 W/min, starting at 40 W. Intrahepatic pressure was as follows: single-step standard ablation, 154.5 +/- 30.9 mmHg; single-step at 30 W, 34.2 +/- 20.0 mmHg; single-step at 70 W, 46.7 +/- 24.3 mmHg; 4-step at 30 W, 42.3 +/- 17.9 mmHg; 8-step at 30 W, 24.1 +/- 18.2 mmHg; 8-step at 70 W, 47.5 +/- 31.5 mmHg; and cooled-tip, 114.5 +/- 16.6 mmHg. The radiofrequency ablation-induced area was spherical with single-step standard ablation, 4-step at 30 W, and 8-step at 30 W. Conversely, the ablated area was irregular with single-step at 30 W, single-step at 70 W, and 8-step at 70 W. The ablation time was significantly shorter for the multi-step method than for the single-step method. Increased intrahepatic pressure could be controlled using multi-step methods. From the shapes of the ablation area, 30-W 8-step expansions appear to be most suitable for radiofrequency ablation.