WorldWideScience

Sample records for radiation measurements arm

  1. Science Plan for the Atmospheric Radiation Measurement Program (ARM)

    International Nuclear Information System (INIS)

    1996-02-01

    The purpose of this Atmospheric Radiation Measurement (ARM) Science Plan is to articulate the scientific issues driving the ARM Program, and to relate them to DOE's programmatic objectives for ARM, based on the experience and scientific progress gained over the past five years. ARM programmatic objectives are to: (1) Relate observed radiative fluxes and radiances in the atmosphere, spectrally resolved and as a function of position and time, to the temperature and composition of the atmosphere, specifically including water vapor and clouds, and to surface properties, and sample sufficient variety of situations so as to span a wide range of climatologically relevant possibilities; (2) develop and test parameterizations that can be used to accurately predict the radiative properties and to model the radiative interactions involving water vapor and clouds within the atmosphere, with the objective of incorporating these parameterizations into general circulation models. The primary observational methods remote sending and other observations at the surface, particularly remote sensing of clouds, water vapor and aerosols

  2. "Atmospheric Radiation Measurement (ARM) Research Facility at Oliktok Point Alaska"

    Science.gov (United States)

    Helsel, F.; Ivey, M.; Hardesty, J.; Roesler, E. L.; Dexheimer, D.

    2017-12-01

    Scientific Infrastructure To Support Atmospheric Science, Aerosol Science and UAS's for The Department Of Energy's Atmospheric Radiation Measurement Programs At The Mobile Facility 3 Located At Oliktok Point, Alaska.The Atmospheric Radiation Measurement (ARM) Program's Mobile Facility 3 (AMF3) located at Oliktok Point, Alaska is a U.S. Department of Energy (DOE) site designed to collect data and help determine the impact that clouds and aerosols have on solar radiation. AMF3 provides a scientific infrastructure to support instruments and collect arctic data for the international arctic research community. The infrastructure at AMF3/Oliktok is designed to be mobile and it may be relocated in the future to support other ARM science missions. AMF3's present base line instruments include: scanning precipitation Radars, cloud Radar, Raman Lidar, Eddy correlation flux systems, Ceilometer, Balloon sounding system, Atmospheric Emitted Radiance Interferometer (AERI), Micro-pulse Lidar (MPL) Along with all the standard metrological measurements. In addition AMF3 provides aerosol measurements with a Mobile Aerosol Observing System (MAOS). Ground support for Unmanned Aerial Systems (UAS) and tethered balloon flights. Data from these instruments and systems are placed in the ARM data archives and are available to the international research community. This poster will discuss what instruments and systems are at the ARM Research Facility at Oliktok Point Alaska.

  3. Satellite data sets for the atmospheric radiation measurement (ARM) program

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L.; Bernstein, R.L. [SeaSpace Corp., San Diego, CA (United States)

    1996-04-01

    This abstract describes the type of data obtained from satellite measurements in the Atmospheric Radiation Measurement (ARM) program. The data sets have been widely used by the ARM team to derive cloud-top altitude, cloud cover, snow and ice cover, surface temperature, water vapor, and wind, vertical profiles of temperature, and continuoous observations of weather needed to track and predict severe weather.

  4. Measurements of surgeons' exposure to ionizing radiation dose: comparison of conventional and mini C-arm fluoroscopy.

    Science.gov (United States)

    Sung, K H; Min, E; Chung, C Y; Jo, B C; Park, M S; Lee, K

    2016-03-01

    This study was performed to measure the equivalent scattered radiation dose delivered to susceptible organs while simulating orthopaedic surgery using conventional and mini C-arm fluoroscopy. In addition, shielding effects on the thyroid, thymus, and gonad, and the direct exposure delivered to the patient's hands were also compared. A conventional and mini C-arms were installed in an operating room, and a hand and an operator phantom were used to simulate a patient's hand and a surgeon. Photoluminescence dosimeters were used to measure the equivalent dose by scattered radiation arriving at the thyroid, thymus, and gonad on a whole-body phantom in the position of the surgeon. Equivalent scattered radiation doses were measured in four groups: (1) unshielded conventional C-arm group; (2) unshielded mini C-arm group; (3) lead-shielded conventional C-arm group; and (4) lead-shielded mini C-arm group. Equivalent scattered radiation doses to the unshielded group were significantly lower in the mini C-arm group than those in the conventional C-arm group for all organs. The gonad in the lead-shielded conventional C-arm group showed the highest equivalent dose among operator-susceptible organs, and radiation dose was reduced by approximately 96% compared with that in the unshielded group. Scattered radiation was not detected in any susceptible organ in the lead-shielded mini C-arm group. The direct radiation dose to the hand phantom measured from the mini C-arm was significantly lower than that measured from the conventional C-arm. The results show that the equivalent scattered radiation dose to the surgeon's susceptible organs and the direct radiation dose to a patient's hand can be decreased significantly by using a mini C-arm rather than a conventional C-arm. However, protective lead garments, such as a thyroid shield and apron, should be applied to minimize radiation exposure to susceptible organs, even during use of mini C-arm fluoroscopy. © The Author(s) 2015.

  5. Measurements of surgeons' exposure to ionizing radiation dose during intraoperative use of C-arm fluoroscopy.

    Science.gov (United States)

    Lee, Kisung; Lee, Kyoung Min; Park, Moon Seok; Lee, Boram; Kwon, Dae Gyu; Chung, Chin Youb

    2012-06-15

    Measurement of radiation dose from C-arm fluoroscopy during a simulated intraoperative use in spine surgery. OBJECTIVE.: To investigate scatter radiation doses to specific organs of surgeons during intraoperative use of C-arm fluoroscopy in spine surgery and to provide practical intraoperative guidelines. There have been studies that reported the radiation dose of C-arm fluoroscopy in various procedures. However, radiation doses to surgeons' specific organs during spine surgery have not been sufficiently examined, and the practical intraoperative radioprotective guidelines have not been suggested. Scatter radiation dose (air kerma rate) was measured during the use of a C-arm on an anthropomorphic chest phantom on an operating table. Then, a whole body anthropomorphic phantom was located besides the chest phantom to simulate a surgeon, and scatter radiation doses to specific organs (eye, thyroid, breast, and gonads) and direct radiation dose to the surgeon's hand were measured using 4 C-arm configurations (standard, inverted, translateral, and tube translateral). The effects of rotating the surgeon's head away from the patient and of a thyroid shield were also evaluated. Scatter radiation doses decreased as distance from the patient increased during C-arm fluoroscopy use. The standard and translateral C-arm configurations caused lower scatter doses to sensitive organs than inverted and tube translateral configurations. Scatter doses were highest for breast and lowest for gonads. The use of a thyroid shield and rotating the surgeon's head away from the patient reduced scatter radiation dose to the surgeon's thyroid and eyes. The direct radiation dose was at least 20 times greater than scatter doses to sensitive organs. The following factors could reduce radiation exposure during intraoperative use of C-arm; (1) distance from the patient, (2) C-arm configuration, (3) radioprotective equipments, (4) rotating the surgeons' eyes away from the patient, and (5) avoiding

  6. Proceedings of the third Atmospheric Radiation Measurement (ARM) science team meeting

    International Nuclear Information System (INIS)

    1994-03-01

    This document contains the summaries of papers presented at the 1993 Atmospheric Radiation Measurement (ARM) Science Team meeting held in Morman, Oklahoma. To put these papers in context, it is useful to consider the history and status of the ARM Program at the time of the meeting. Individual papers have been cataloged separately

  7. Proceedings of the third Atmospheric Radiation Measurement (ARM) science team meeting

    Energy Technology Data Exchange (ETDEWEB)

    1994-03-01

    This document contains the summaries of papers presented at the 1993 Atmospheric Radiation Measurement (ARM) Science Team meeting held in Morman, Oklahoma. To put these papers in context, it is useful to consider the history and status of the ARM Program at the time of the meeting. Individual papers have been cataloged separately.

  8. ARM Airborne Carbon Measurements (ARM-ACME) and ARM-ACME 2.5 Final Campaign Reports

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Tom, M. S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sweeney, C. [NOAA Earth Systems Research Lab., Boulder, CO (United States)

    2016-01-01

    We report on a 5-year multi-institution and multi-agency airborne study of atmospheric composition and carbon cycling at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, with scientific objectives that are central to the carbon-cycle and radiative-forcing goals of the U.S. Global Change Research Program and the North American Carbon Program (NACP). The goal of these measurements is to improve understanding of 1) the carbon exchange of the Atmospheric Radiation Measurement (ARM) SGP region; 2) how CO2 and associated water and energy fluxes influence radiative-forcing, convective processes, and CO2 concentrations over the ARM SGP region, and 3) how greenhouse gases are transported on continental scales.

  9. Atmospheric Radiation Measurement (ARM) Climate Research Facility Management Plan

    Energy Technology Data Exchange (ETDEWEB)

    Mather, James [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-04-01

    Mission and Vision Statements for the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mission The ARM Climate Research Facility, a DOE scientific user facility, provides the climate research community with strategically located in situ and remote-sensing observatories designed to improve the understanding and representation, in climate and earth system models, of clouds and aerosols as well as their interactions and coupling with the Earth’s surface. Vision To provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes to resolve the uncertainties in climate and Earth system models toward the development of sustainable solutions for the nation's energy and environmental challenges.

  10. User interface development and metadata considerations for the Atmospheric Radiation Measurement (ARM) archive

    Science.gov (United States)

    Singley, P. T.; Bell, J. D.; Daugherty, P. F.; Hubbs, C. A.; Tuggle, J. G.

    1993-01-01

    This paper will discuss user interface development and the structure and use of metadata for the Atmospheric Radiation Measurement (ARM) Archive. The ARM Archive, located at Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, is the data repository for the U.S. Department of Energy's (DOE's) ARM Project. After a short description of the ARM Project and the ARM Archive's role, we will consider the philosophy and goals, constraints, and prototype implementation of the user interface for the archive. We will also describe the metadata that are stored at the archive and support the user interface.

  11. ARM Airborne Carbon Measurements VI (ARM-ACME VI) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Biraud, Sebastien [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-05-01

    From October 1, 2015 through September 30, 2016, AAF deployed a Cessna 206 aircraft over the Southern Great Plains, collecting observations of trace gas mixing ratios over the ARM/SGP Central Facility. The aircraft payload included two Atmospheric Observing Systems (AOS Inc.) analyzers for continuous measurements of CO2, and a 12-flask sampler for analysis of carbon cycle gases (CO2, CO, CH4, N2O, 13CO2). The aircraft payload also includes solar/infrared radiation measurements. This research (supported by DOE ARM and TES programs) builds upon previous ARM-ACME missions. The goal of these measurements is to improve understanding of: (a) the carbon exchange of the ARM region; (b) how CO2 and associated water and energy fluxes influence radiative forcing, convective processes, and CO2 concentrations over the ARM region, and (c) how greenhouse gases are transported on continental scales.

  12. Proceedings of the second Atmospheric Radiation Measurement (ARM) Science Team Meeting

    International Nuclear Information System (INIS)

    1992-12-01

    The second Atmospheric Radiation Measurement (ARM) Science Team Meeting was held in Denver, Colorado, in October 1991. The five-day meeting provided a forum for a technical exchange among the members of the ARM Science Team and a discussion of the technical aspects of the project infrastructure. The meeting included several activities: Science Team presentations, discussions of the first site occupation plan, experiment design sessions, and poster sessions. This Proceedings document includes papers presented at the meeting. The papers included are those from the technical sessions, the experiment design sessions, the first site occupation, and descriptions of locales for future sites. Individual projects are processed separately for the database

  13. Environmental assessment for the Atmospheric Radiation Measurement (ARM) Program: Southern Great Plains Cloud and Radiation Testbed (CART) site

    International Nuclear Information System (INIS)

    Policastro, A.J.; Pfingston, J.M.; Maloney, D.M.; Wasmer, F.; Pentecost, E.D.

    1992-03-01

    The Atmospheric Radiation Measurement (ARM) Program is aimed at supplying improved predictive capability of climate change, particularly the prediction of cloud-climate feedback. The objective will be achieved by measuring the atmospheric radiation and physical and meteorological quantities that control solar radiation in the earth's atmosphere and using this information to test global climate and related models. The proposed action is to construct and operate a Cloud and Radiation Testbed (CART) research site in the southern Great Plains as part of the Department of Energy's Atmospheric Radiation Measurement Program whose objective is to develop an improved predictive capability of global climate change. The purpose of this CART research site in southern Kansas and northern Oklahoma would be to collect meteorological and other scientific information to better characterize the processes controlling radiation transfer on a global scale. Impacts which could result from this facility are described

  14. Environmental assessment for the Atmospheric Radiation Measurement (ARM) Program: Southern Great Plains Cloud and Radiation Testbed (CART) site

    Energy Technology Data Exchange (ETDEWEB)

    Policastro, A.J.; Pfingston, J.M.; Maloney, D.M.; Wasmer, F.; Pentecost, E.D.

    1992-03-01

    The Atmospheric Radiation Measurement (ARM) Program is aimed at supplying improved predictive capability of climate change, particularly the prediction of cloud-climate feedback. The objective will be achieved by measuring the atmospheric radiation and physical and meteorological quantities that control solar radiation in the earth`s atmosphere and using this information to test global climate and related models. The proposed action is to construct and operate a Cloud and Radiation Testbed (CART) research site in the southern Great Plains as part of the Department of Energy`s Atmospheric Radiation Measurement Program whose objective is to develop an improved predictive capability of global climate change. The purpose of this CART research site in southern Kansas and northern Oklahoma would be to collect meteorological and other scientific information to better characterize the processes controlling radiation transfer on a global scale. Impacts which could result from this facility are described.

  15. Single-column data assimilation for the Atmospheric Radiation Measurement (ARM) Program

    International Nuclear Information System (INIS)

    Louis, J.F.

    1994-01-01

    The main purpose of the ARM program is to provide the necessary data to develop, test and validate the parameterization of clouds and of their interactions with the radiation field, and the computation of radiative transfer in climate models. For various reasons, much of the ARM observations will be imperfect, incomplete, redundant, indirect and unrepresentative. Various techniques of data assimilation have been developed to deal with these problems. The variational data assimilation and adjoint method applied to a single column model is described here. A model is used to simulate the evolution of the atmosphere during an assimilation period. As the model is run, a cost function is computed which is essentially a measure of simulation errors. The method then consists in adjusting some model parameters to minimize the cost function. Optimization of the model parameters needs to be done with a much longer series of data, to cover different meteorological situations. Once parameters are set, nudging terms are used as control variables. The Derber nudging method will require considerable tuning, especially in defining the vertical profiles of the nudging terms. Extensive tests are currently underway of both model optimization and data assimilation

  16. Measurement and Modeling of Vertically Resolved Aerosol Optical Properties and Radiative Fluxes Over the ARM SGP Site

    Science.gov (United States)

    Schmid, B.; Arnott, P.; Bucholtz, A.; Colarco, P.; Covert, D.; Eilers, J.; Elleman, R.; Ferrare, R.; Flagan, R.; Jonsson, H.

    2003-01-01

    In order to meet one of its goals - to relate observations of radiative fluxes and radiances to the atmospheric composition - the Department of Energy's Atmospheric Radiation Measurement (ARM) program has pursued measurements and modeling activities that attempt to determine how aerosols impact atmospheric radiative transfer, both directly and indirectly. However, significant discrepancies between aerosol properties measured in situ or remotely remain. One of the objectives of the Aerosol Intensive Operational Period (TOP) conducted by ARM in May 2003 at the ARM Southern Great Plains (SGP) site in north central Oklahoma was to examine and hopefully reduce these differences. The IOP involved airborne measurements from two airplanes over the heavily instrumented SGP site. We give an overview of airborne results obtained aboard the Center for Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter aircraft. The Twin Otter performed 16 research flights over the SGP site. The aircraft carried instrumentation to perform in-situ measurements of aerosol absorption, scattering, extinction and particle size. This included such novel techniques as the photoacoustic and cavity ring-down methods for in-situ absorption (675 nm) and extinction (675 and 1550 nm) and a new multiwavelength, filter-based absorption photometer (467, 530, 660 nm). A newly developed instrument measured cloud condensation nucleus concentration (CCN) concentrations at two supersaturation levels. Aerosol optical depth and extinction (354-2139 nm) were measured with the NASA Ames Airborne Tracking 14-channel sunphotometer. Furthermore, up-and downwelling solar (broadband and spectral) and infrared radiation were measured using seven individual radiometers. Three up-looking radiometers werer mounted on a newly developed stabilized platform, keeping the instruments level up to aircraft pitch and roll angles of approximately 10(exp 0). This resulted in unprecedented continuous vertical profiles

  17. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    Science.gov (United States)

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  18. Proceedings of the sixth Atmospheric Radiation Measurement (ARM) Science Team meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    This document contains the summaries of papers presented at the 1996 Atmospheric Radiation Measurement (ARM) Science Team meeting held at San Antonio, Texas. The history and status of the ARM program at the time of the meeting helps to put these papers in context. The basic themes have not changed. First, from its beginning, the Program has attempted to respond to the most critical scientific issues facing the US Global Change Research Program. Second, the Program has been strongly coupled to other agency and international programs. More specifically, the Program reflects an unprecedented collaboration among agencies of the federal research community, among the US Department of Energy`s (DOE) national laboratories, and between DOE`s research program and related international programs, such as Global Energy and Water Experiment (GEWEX) and the Tropical Ocean Global Atmosphere (TOGA) program. Next, ARM has always attempted to make the most judicious use of its resources by collaborating and leveraging existing assets and has managed to maintain an aggressive schedule despite budgets that have been much smaller than planned. Finally, the Program has attracted some of the very best scientific talent in the climate research community and has, as a result, been productive scientifically.

  19. Atmospheric Radiation Measurement Program Science Plan. Current Status and Future Directions of the ARM Science Program

    Energy Technology Data Exchange (ETDEWEB)

    Ackerman, Thomas P.; Del Genio, Anthony D.; Ellingson, Robert G.; Ferrare, Richard A.; Klein, Steve A.; McFarquhar, Gregory M.; Lamb, Peter J.; Long, Charles M.; Verlinde, Johannes

    2004-10-30

    The Atmospheric Radiation Measurement (ARM) Program has matured into one of the key programs in the U.S. Climate Change Science Program. The ARM Program has achieved considerable scientific success in a broad range of activities, including site and instrument development, atmospheric radiative transfer, aerosol science, determination of cloud properties, cloud modeling, and cloud parameterization testing and development. The focus of ARM science has naturally shifted during the last few years to an increasing emphasis on modeling and parameterization studies to take advantage of the long time series of data now available. During the next 5 years, the principal focus of the ARM science program will be to: Maintain the data record at the fixed ARM sites for at least the next five years; Improve significantly our understanding of and ability to parameterize the 3-D cloud-radiation problem at scales from the local atmospheric column to the global climate model (GCM) grid square; Continue developing techniques to retrieve the properties of all clouds, with a special focus on ice clouds and mixed-phase clouds; Develop a focused research effort on the indirect aerosol problem that spans observations, physical models, and climate model parameterizations; Implement and evaluate an operational methodology to calculate broad-band heating rates in the atmospheric columns at the ARM sites; Develop and implement methodologies to use ARM data more effectively to test atmospheric models, both at the cloud-resolving model scale and the GCM scale; and, Use these methodologies to diagnose cloud parameterization performance and then refine these parameterizations to improve the accuracy of climate model simulations. In addition, the ARM Program is actively developing a new ARM Mobile Facility (AMF) that will be available for short deployments (several months to a year or more) in climatically important regions. The AMF will have much of the same instrumentation as the remote

  20. Raman lidar measurements of water vapor and aerosols during the atmospheric radiation measurement (ARM) remote clouds sensing (RCS) intensive observation period (IOP)

    Energy Technology Data Exchange (ETDEWEB)

    Melfi, S.H.; Starr, D.O`C.; Whiteman, D. [NASA Goddard Space Flight Center, Greenbelt, MD (United States)] [and others

    1996-04-01

    The first Atmospheric Radiation Measurement (ARM) remote Cloud Study (RCS) Intensive Operations Period (IOP) was held during April 1994 at the Southern Great Plains (SGP) site. This experiment was conducted to evaluate and calibrate state-of-the-art, ground based remote sensing instruments and to use the data acquired by these instruments to validate retrieval algorithms developed under the ARM program.

  1. Use of the ARM Measurements of Spectral Zenith Radiance for Better Understanding of 3D Cloud-Radiation Processes & Aerosol-Cloud Interaction

    Energy Technology Data Exchange (ETDEWEB)

    Alexander Marshak; Warren Wiscombe; Yuri Knyazikhin; Christine Chiu

    2011-05-24

    We proposed a variety of tasks centered on the following question: what can we learn about 3D cloud-radiation processes and aerosol-cloud interaction from rapid-sampling ARM measurements of spectral zenith radiance? These ARM measurements offer spectacular new and largely unexploited capabilities in both the temporal and spectral domains. Unlike most other ARM instruments, which average over many seconds or take samples many seconds apart, the new spectral zenith radiance measurements are fast enough to resolve natural time scales of cloud change and cloud boundaries as well as the transition zone between cloudy and clear areas. In the case of the shortwave spectrometer, the measurements offer high time resolution and high spectral resolution, allowing new discovery-oriented science which we intend to pursue vigorously. Research objectives are, for convenience, grouped under three themes: • Understand radiative signature of the transition zone between cloud-free and cloudy areas using data from ARM shortwave radiometers, which has major climatic consequences in both aerosol direct and indirect effect studies. • Provide cloud property retrievals from the ARM sites and the ARM Mobile Facility for studies of aerosol-cloud interactions. • Assess impact of 3D cloud structures on aerosol properties using passive and active remote sensing techniques from both ARM and satellite measurements.

  2. Radiation Pattern of Chair Armed Microstrip Antenna

    Science.gov (United States)

    Mishra, Rabindra Kishore; Sahu, Kumar Satyabrat

    2016-12-01

    This work analyzes planar antenna conformable to chair arm shaped surfaces for WLAN application. Closed form expressions for its radiation pattern are developed and validated using measurements on prototype and commercial EM code at 2.4 GHz.

  3. Proceedings of the fifth Atmospheric Radiation Measurement (ARM) science team meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    This document contains the summaries of papers presented at the 1995 Atmospheric Radiation Measurement (ARM) Science Team meeting held in San Diego, California. To put these papers in context, it is useful to consider the history and status of the ARM program at the time of the meeting. The history of the project has several themes. First, the Program has from its very beginning attempted to respond to most critical scientific issues facing the US Global Change Research Program. Second, the Program has been strongly coupled to other agency and international programs. Indeed, the Program reflects an unprecedented collaboration among various elements of the federal research community, among the US Department of Energy`s national laboratories, and between an agency`s research program and the related international programs, such as Global Energy and Water Experiment and TOGA. Next, ARM has always attempted to make the most judicious use of its resources by collaborating and leveraging existing assets and has managed to maintain an aggressive schedule despite budgets that have been much smaller than planned. Finally, the Program has attracted some of the very best scientific talent in the climate research community and has, as a result, been productive scientifically. This introduction covers the first three points--the papers themselves speak to the last point. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  4. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Laboratory; Sisterson, DL [Argonne National Laboratory

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily-accessible, well-articulated estimate of ARM measurement uncertainty is needed.

  5. Measurement Capabilities of the DOE ARM Aerial Facility

    Science.gov (United States)

    Schmid, B.; Tomlinson, J. M.; Hubbe, J.; Comstock, J. M.; Kluzek, C. D.; Chand, D.; Pekour, M. S.

    2012-12-01

    The Department of Energy Atmospheric Radiation Measurement (ARM) Program is a climate research user facility operating stationary ground sites in three important climatic regimes that provide long-term measurements of climate relevant properties. ARM also operates mobile ground- and ship-based facilities to conduct shorter field campaigns (6-12 months) to investigate understudied climate regimes around the globe. Finally, airborne observations by ARM's Aerial Facility (AAF) enhance the surface-based ARM measurements by providing high-resolution in situ measurements for process understanding, retrieval algorithm development, and model evaluation that is not possible using ground-based techniques. AAF started out in 2007 as a "virtual hangar" with no dedicated aircraft and only a small number of instruments owned by ARM. In this mode, AAF successfully carried out several missions contracting with organizations and investigators who provided their research aircraft and instrumentation. In 2009, the Battelle owned G-1 aircraft was included in the ARM facility. The G-1 is a large twin turboprop aircraft, capable of measurements up to altitudes of 7.5 km and a range of 2,800 kilometers. Furthermore the American Recovery and Reinvestment Act of 2009 provided funding for the procurement of seventeen new instruments to be used aboard the G-1 and other AAF virtual-hangar aircraft. AAF now executes missions in the virtual- and real-hangar mode producing freely available datasets for studying aerosol, cloud, and radiative processes in the atmosphere. AAF is also heavily engaged in the maturation and testing of newly developed airborne sensors to help foster the next generation of airborne instruments. In the presentation we will showcase science applications based on measurements from recent field campaigns such as CARES, CALWATER and TCAP.

  6. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report

    Energy Technology Data Exchange (ETDEWEB)

    Campos, E [Argonne National Lab. (ANL), Argonne, IL (United States); Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. The ARM Facility currently provides data and supporting metadata (information about the data or data quality) to its users through a number of sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, the Facility relies on instrument mentors and the ARM Data Quality Office (DQO) to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. Note that some of the instrument observations require mathematical algorithms (retrievals) to convert a measured engineering variable into a useful geophysical measurement. While those types of retrieval measurements are identified, this study does not address particular methods for retrieval uncertainty. As well, the ARM Facility also provides engineered data products, or value-added products (VAPs), based on multiple instrument measurements. This study does not include uncertainty estimates for those data products. We propose here that a total measurement uncertainty should be calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). The study will not expand on methods for computing these uncertainties. Instead, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available in the ARM community through the ARM instrument mentors and their ARM instrument handbooks. As a result, this study will address the first steps towards reporting ARM measurement uncertainty

  7. Understanding the scatter radiation distribution during C-arm CT examination. A body phantom study

    International Nuclear Information System (INIS)

    Norimasa, Toshiyo; Kakimi, Akihiko; Takao, Yoshinori; Sasaki, Shohei; Katayama, Yutaka; Himoto, Daisuke; Izuta, Shinichiro; Ichida, Takao

    2016-01-01

    The purpose of this study was to understand the scatter radiation distribution during C-arm CT examination in the interventional radiography (IVR) room to show the escaped area and the radiation protective method. The C-arm rotates 200deg in 5 s. The tube voltage was 90 kV, and the entrance dose to the detector was 0.36 μGy/frame during C-arm CT examination. The scattered doses were measured each 50 cm from the isocenter like a grid pattern. The heights of the measurement were 50, 100, and 150 cm from the floor. The maximum scattered doses were 38.23 ± 0.60 μGy at 50 cm, 43.86 ± 20 μGy at 100 cm, and 25.78 ± 0.37 μGy at 150 cm. The scatter radiation distribution at 100 cm was the highest scattered dose. The operator should protect their reproductive gland, thyroid, and lens. The scattered dose was low behind the C-arm body and the bed, so they will be able to become the escaped area for staff. (author)

  8. A research program on radiative transfer model development in support of the ARM program

    International Nuclear Information System (INIS)

    Clough, S.A.

    1993-01-01

    The objective of this research effort is to develop radiative transfer models that are consistent with ARM spectral radiance measurements for clear and cloudy atmospheres. Our approach is to develop the model physics and related databases with a line-by-line model in the context of available spectral radiance measurements. The line-by-line model then functions as an intermediate standard to both develop and validate rapid radiative transfer models appropriate to GCM applications. A preprint of an extended abstract for the 1994 AMS volume describing a Quality Measurement Experiment using the ARM spectral data is included as an attachment

  9. Southern Great Plains Atmospheric Radiation Measurement Site

    Data.gov (United States)

    Federal Laboratory Consortium — The Southern Great Plains Atmospheric Radiation Measurement Site (SGP-ARM) is the oldest and largest of DOE's Arm sites. It was established in 1992. It consists of...

  10. Atmospheric Radiation Measurement Climate Research (ARM)

    Data.gov (United States)

    Federal Laboratory Consortium — With heavily instrumented field sites around the globe, the ARM Climate Research Facility provides the world's most comprehensive outdoor laboratory and data archive...

  11. A Unified Approach for Reporting ARM Measurement Uncertainties Technical Report: Updated in 2016

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, Douglas [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-01-15

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is observationally based, and quantifying the uncertainty of its measurements is critically important. With over 300 widely differing instruments providing over 2,500 datastreams, concise expression of measurement uncertainty is quite challenging. ARM currently provides data and supporting metadata (information about the data or data quality) to its users through several sources. Because the continued success of the ARM Facility depends on the known quality of its measurements, ARM relies on Instrument Mentors and the ARM Data Quality Office to ensure, assess, and report measurement quality. Therefore, an easily accessible, well-articulated estimate of ARM measurement uncertainty is needed. This report is a continuation of the work presented by Campos and Sisterson (2015) and provides additional uncertainty information from instruments not available in their report. As before, a total measurement uncertainty has been calculated as a function of the instrument uncertainty (calibration factors), the field uncertainty (environmental factors), and the retrieval uncertainty (algorithm factors). This study will not expand on methods for computing these uncertainties. As before, it will focus on the practical identification, characterization, and inventory of the measurement uncertainties already available to the ARM community through the ARM Instrument Mentors and their ARM instrument handbooks. This study continues the first steps towards reporting ARM measurement uncertainty as: (1) identifying how the uncertainty of individual ARM measurements is currently expressed, (2) identifying a consistent approach to measurement uncertainty, and then (3) reclassifying ARM instrument measurement uncertainties in a common framework.

  12. Overview of the aerial radiological measuring system (ARMS) program

    International Nuclear Information System (INIS)

    Deal, L.J.; Doyle, J.F. III.

    1975-01-01

    Since 1960 EG and G, Inc. has developed and maintained for the U.S. Energy Research and Development Administration (ERDA) a state-of-the-art radiation surveillance program called the Aerial Radiological Measuring System (ARMS). Radiological surveys covering more than 300,000 square miles have been performed. In addition to the radiation detector gear, the system includes an inertial navigation system, radar altimeter, meteorological probes, air sampler, air sample analyzer, multispectral cameras, aerial mapping camera and infrared scanner. The recently improved data acquisition system, REDAR, records all inputs digitally on magnetic tape and is readily mounted in fixed-wing aircraft or helicopters. The data analysis system, REDAC, is mounted in a mobile processing laboratory which accompanies the aircraft on surveys. Radiation isopleth maps, both for gross counts and selected isotopes, can be prepared in the field. Special computer software enables the ARMS to detect changes of less than 1.0 μR/hr in exposure rates between successive surveys of a given site

  13. Atmospheric Radiation Measurement Program plan

    International Nuclear Information System (INIS)

    1990-02-01

    In order to understand energy's role in anthropogenic global climate change, significant reliance is being placed on General Circulation Models (GCMs). A major goal is to foster the development of GCMs capable of predicting the timing and magnitude of greenhouse gas-induced global warming and the regional effects of such warming. The Atmospheric Radiation Measurement (ARM) Program will contribute to the Department of Energy goal by improving the treatment of cloud radiative forcing and feedbacks in GCMs. Two issues will be addressed: the radiation budget and its spectral dependence and the radiative and other properties of clouds. The experimental objective of the ARM Program is to characterize empirically the radiative processes in the Earth's atmosphere with improved resolution and accuracy. A key to this characterization is the effective treatment of cloud formation and cloud properties in GCMs. Through this characterization of radiative properties, it will be possible to understand both the forcing and feedback effects. 19 refs., 4 figs., 2 tabs

  14. Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Frank; Clausen, Sven; Jahnke, Anika; Steil, Volker; Wenz, Frederik [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Radiation Oncology; Bludau, Frederic; Obertacke, Udo [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Trauma Surgery; Suetterlin, Marc [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Obstetrics and Gynaecology

    2014-10-01

    Background: Intraoperative radiotherapy (IORT) using the INTRABEAM {sup registered} system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with {sup 192}Ir or {sup 60}Co. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 μSv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses > 6 mSv) for each paradigm of about 4 m ± 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM {sup registered} system. (orig.)

  15. The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu [Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota (United States); Brinkmann, Debra H.; Ward, Shelly B. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Durski, Jolanta [Department of Radiology, Nuclear Medicine Program, Mayo Clinic, Rochester, Minnesota (United States); Laack, Nadia N.; Yan, Elizabeth; Schomberg, Paula J.; Garces, Yolanda I. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Suman, Vera J. [Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States); Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2013-03-15

    Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.

  16. The addition of SPECT/CT lymphoscintigraphy to breast cancer radiation planning spares lymph nodes critical for arm drainage.

    Science.gov (United States)

    Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A

    2013-03-15

    This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Atmospheric radiation measurement: A program for improving radiative forcing and feedback in general circulation models

    International Nuclear Information System (INIS)

    Patrinos, A.A.; Renne, D.S.; Stokes, G.M.; Ellingson, R.G.

    1991-01-01

    The Atmospheric Radiation Measurement (ARM) Program is a key element of the Department of Energy's (DOE's) global change research strategy. ARM represents a long-term commitment to conduct comprehensive studies of the spectral atmospheric radiative energy balance profile for a wide range of cloud conditions and surface types, and to develop the knowledge necessary to improve parameterizations of radiative processes under various cloud regimes for use in general circulation models (GCMs) and related models. The importance of the ARM program is a apparent from the results of model assessments of the impact on global climate change. Recent studies suggest that radiatively active trace gas emissions caused by human activity can lead to a global warming of 1.5 to 4.5 degrees Celsius and to important changes in water availability during the next century (Cess, et al. 1989). These broad-scale changes can be even more significant at regional levels, where large shifts in temperature and precipitation patterns are shown to occur. However, these analyses also indicate that considerable uncertainty exists in these estimates, with the manner in which cloud radiative processes are parameterized among the most significant uncertainty. Thus, although the findings have significant policy implications in assessment of global and regional climate change, their uncertainties greatly influence the policy debate. ARM's highly focused observational and analytical research is intended to accelerate improvements and reduce key uncertainties associated with the way in which GCMs treat cloud cover and cloud characteristics and the resulting radiative forcing. This paper summarizes the scientific context for ARM, ARM's experimental approach, and recent activities within the ARM program

  18. The possible direct use of satellite radiance measurements by the Atmospheric Radiation Measurement Program

    International Nuclear Information System (INIS)

    1993-03-01

    The Atmospheric Radiation Measurement (ARM) Program is a major research program initiated by the Department of Energy to improve our understanding of radiative and cloud processes critical to predicting the Earth's climate and its changes. Central to this concept is the use of four to six intensively instrumented sites for long-term study and characterization of the processes of interest. The instrumentation suites will include ground-based, high-accuracy radiometers for measuring the short and longwave surface flux, as well as an extensive set of ground-and air-based instrumentation for characterizing the intervening atmospheric column. Satellite-based measurements are expected to play a very important role in providing top-of-the-atmosphere measurements. In this study, we examine the possibility of comparing ARM outputs directly with satellite measurements, thereby ensuring the independence of these two important data sets. Thus we focused on what do satellites really measure and how well do they measure it. On what can we do about the general lack of adequate visible channel calibration. On what is the best way for ARM to obtain near-real-time access to this unprocessed data. And on what is the optimum way for ARM to make use of satellite data

  19. Atmospheric Radiation Measurement Climate Research Facility (ACRF) Annual Report 2008

    Energy Technology Data Exchange (ETDEWEB)

    LR Roeder

    2008-12-01

    The Importance of Clouds and Radiation for Climate Change: The Earth’s surface temperature is determined by the balance between incoming solar radiation and thermal (or infrared) radiation emitted by the Earth back to space. Changes in atmospheric composition, including greenhouse gases, clouds, and aerosols, can alter this balance and produce significant climate change. Global climate models (GCMs) are the primary tool for quantifying future climate change; however, there remain significant uncertainties in the GCM treatment of clouds, aerosol, and their effects on the Earth’s energy balance. In 1989, the U.S. Department of Energy (DOE) Office of Science created the Atmospheric Radiation Measurement (ARM) Program to address scientific uncertainties related to global climate change, with a specific focus on the crucial role of clouds and their influence on the transfer of radiation in the atmosphere. To reduce these scientific uncertainties, the ARM Program uses a unique twopronged approach: • The ARM Climate Research Facility, a scientific user facility for obtaining long-term measurements of radiative fluxes, cloud and aerosol properties, and related atmospheric characteristics in diverse climate regimes; and • The ARM Science Program, focused on the analysis of ACRF and other data to address climate science issues associated with clouds, aerosols, and radiation, and to improve GCMs. This report provides an overview of each of these components and a sample of achievements for each in fiscal year (FY) 2008.

  20. Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.

    Science.gov (United States)

    Martin, Dennis P; Chapman, Talia; Williamson, Christopher; Tinsley, Brian; Ilyas, Asif M; Wang, Mark L

    2017-11-01

    This study aims to test the hypothesis that: (1) radiation exposure is increased with the intended use of Flat Surface Image Intensifier (FSII) units above the operative surface compared with the traditional below-table configuration; (2) this differential increases in a dose-dependent manner; and (3) radiation exposure varies with body part and proximity to the radiation source. A surgeon mannequin was seated at a radiolucent hand table, positioned for volar distal radius plating. Thermoluminescent dosimeters measured exposure to the eyes, thyroid, chest, hand, and groin, for 1- and 15-minute trials from a mini C-arm FSII unit positioned above and below the operating surface. Background radiation was measured by control dosimeters placed within the operating theater. At 1-minute of exposure, hand and eye dosages were significantly greater with the flat detector positioned above the table. At 15-minutes of exposure, hand radiation dosage exceeded that of all other anatomic sites with the FSII in both positions. Hand exposure was increased in a dose-dependent manner with the flat detector in either position, whereas groin exposure saw a dose-dependent only with the flat detector beneath the operating table. These findings suggest that the surgeon's hands and eyes may incur greater radiation exposure compared with other body parts, during routine mini C-arm FSII utilization in its intended position above the operating table. The clinical impact of these findings remains unclear, and future long-term radiation safety investigation is warranted. Surgeons should take precautions to protect critical body parts, particularly when using FSII technology above the operating with prolonged exposure time.

  1. Using the Atmospheric Radiation Measurement (ARM) Datasets to Evaluate Climate Models in Simulating Diurnal and Seasonal Variations of Tropical Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hailong [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland, Washington; Burleyson, Casey D. [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland, Washington; Ma, Po-Lun [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland, Washington; Fast, Jerome D. [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland, Washington; Rasch, Philip J. [Atmospheric Sciences and Global Change Division, Pacific Northwest National Laboratory, Richland, Washington

    2018-04-01

    We use the long-term Atmospheric Radiation Measurement (ARM) datasets collected at the three Tropical Western Pacific (TWP) sites as a tropical testbed to evaluate the ability of the Community Atmosphere Model (CAM5) to simulate the various types of clouds, their seasonal and diurnal variations, and their impact on surface radiation. We conducted a series of CAM5 simulations at various horizontal grid spacing (around 2°, 1°, 0.5°, and 0.25°) with meteorological constraints from reanalysis. Model biases in the seasonal cycle of cloudiness are found to be weakly dependent on model resolution. Positive biases (up to 20%) in the annual mean total cloud fraction appear mostly in stratiform ice clouds. Higher-resolution simulations do reduce the positive bias in the frequency of ice clouds, but they inadvertently increase the negative biases in convective clouds and low-level liquid clouds, leading to a positive bias in annual mean shortwave fluxes at the sites, as high as 65 W m-2 in the 0.25° simulation. Such resolution-dependent biases in clouds can adversely lead to biases in ambient thermodynamic properties and, in turn, feedback on clouds. Both the CAM5 model and ARM observations show distinct diurnal cycles in total, stratiform and convective cloud fractions; however, they are out-of-phase by 12 hours and the biases vary by site. Our results suggest that biases in deep convection affect the vertical distribution and diurnal cycle of stratiform clouds through the transport of vapor and/or the detrainment of liquid and ice. We also found that the modelled gridmean surface longwave fluxes are systematically larger than site measurements when the grid that the ARM sites reside in is partially covered by ocean. The modeled longwave fluxes at such sites also lack a discernable diurnal cycle because the ocean part of the grid is warmer and less sensitive to radiative heating/cooling compared to land. Higher spatial resolution is more helpful is this regard. Our

  2. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  3. Broadband Outdoor Radiometer Calibration Process for the Atmospheric Radiation Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.

  4. [Radiative and hygienic certification in Armed Forces, problems of its implementation and ways of perfection].

    Science.gov (United States)

    Rusakov, V N; Cherkashin, A V; Shishkanov, A P; Ian'shin, L A; Gracheva, T N

    2010-12-01

    Radiative and hygienic passportization is one of the most actual pattern of socio and hygienic monitoring in Armed Forces. Radiative and hygienic passport is the main document which characterizes the safety control in military unit and uses the sources of ionizing radiation. Sanitary and epidemiologic institutions were imputed to control the formation of radiative and hygienic passports, analysis and generalization of its data, formation of conclusions about the condition of radiation security in the military units. According to radiative and hygienic passportization, which took place in 2009, the radiation security in the Armed Forces and organizations is satisfactory, but there are some problems of providing of radiation security of personnel under the professional and medical radiation. The salvation of its problems requires the effective work of official functionary of radiac object and institutions of state sanitary and epidemiological supervision in Armed Forces of Russian Federation.

  5. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  6. The Atmospheric Radiation Measurement Program and interfaces with external data sources

    International Nuclear Information System (INIS)

    Stokes, G.M.; Cress, T.S.; Melton, R.B.

    1993-10-01

    The Atmospheric Radiation Measurement (ARM) Program is the Department of Energy's major field project in support of its global change research program. Its objective is to improve the performance of cloud and radiation models and parameterizations in general circulation models (GCMs) used for climate research. The data produced by ARM will be handled and maintained to satisfy the research needs of the program and to be accessible and usable by the general research and academic communities. In addition to data from field instrumentation, ARM Science Team needs include a substantial amount of data from outside the ARM Program (''external data''), which will be acquired and provided routinely through the ARM data system. With respect to data archival and sharing, the ARM Program reflects the objectives delineated by the US Global Change. The purpose of this presentation is to summarize the conceptual designs embodied in the ARM data system and the status of its implementation

  7. Atmospheric radiation measurement program facilities newsletter, June 2002.; TOPICAL

    International Nuclear Information System (INIS)

    Holdridge, D. J.

    2002-01-01

    ARM Intensive Operational Period Scheduled to Validate New NASA Satellite-Beginning in July, all three ARM sites (Southern Great Plains[SGP], North Slope of Alaska, and Tropical Western Pacific; Figure 1) will participate in the AIRS Validation IOP. This three-month intensive operational period (IOP) will validate data collected by the satellite-based Atmospheric Infrared Sounder (AIRS) recently launched into space. On May 4, the National Aeronautics and Space Administration (NASA) launched Aqua, the second spacecraft in the Earth Observing System (EOS) series. The EOS satellites monitor Earth systems including land surfaces, oceans, the atmosphere, and ice cover. The first EOS satellite, named Terra, was launched in December 1999. The second EOS satellite is named Aqua because its primary focus is understanding Earth's water cycle through observation of atmospheric moisture, clouds, temperature, ocean surface, precipitation, and soil moisture. One of the instruments aboard Aqua is the AIRS, built by the Jet Propulsion Laboratory, a NASA agency. The AIRS Validation IOP complements the ARM mission to improve understanding of the interactions of clouds and atmospheric moisture with solar radiation and their influence on weather and climate. In support of satellite validation IOP, ARM will launch dedicated radiosondes at all three ARM sites while the Aqua satellite with the AIRS instrument is orbiting overhead. These radiosonde launches will occur 45 minutes and 5 minutes before selected satellite overpasses. In addition, visiting scientists from the Jet Propulsion Laboratory will launch special radiosondes to measure ozone and humidity over the SGP site. All launches will generate ground-truth data to validate satellite data collected simultaneously. Data gathered daily by ARM meteorological and solar radiation instruments will complete the validation data sets. Data from Aqua-based instruments, including AIRS, will aid in weather forecasting, climate modeling, and

  8. Improved Correction of IR Loss in Diffuse Shortwave Measurements: An ARM Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Younkin, K; Long, CN

    2003-11-01

    Simple single black detector pyranometers, such as the Eppley Precision Spectral Pyranometer (PSP) used by the Atmospheric Radiation Measurement (ARM) Program, are known to lose energy via infrared (IR) emission to the sky. This is especially a problem when making clear-sky diffuse shortwave (SW) measurements, which are inherently of low magnitude and suffer the greatest IR loss. Dutton et al. (2001) proposed a technique using information from collocated pyrgeometers to help compensate for this IR loss. The technique uses an empirically derived relationship between the pyrgeometer detector data (and alternatively the detector data plus the difference between the pyrgeometer case and dome temperatures) and the nighttime pyranometer IR loss data. This relationship is then used to apply a correction to the diffuse SW data during daylight hours. We developed an ARM value-added product (VAP) called the SW DIFF CORR 1DUTT VAP to apply the Dutton et al. correction technique to ARM PSP diffuse SW measurements.

  9. Single-Column Modeling, GCM Parameterizations and Atmospheric Radiation Measurement Data

    International Nuclear Information System (INIS)

    Somerville, R.C.J.; Iacobellis, S.F.

    2005-01-01

    Our overall goal is identical to that of the Atmospheric Radiation Measurement (ARM) Program: the development of new and improved parameterizations of cloud-radiation effects and related processes, using ARM data at all three ARM sites, and the implementation and testing of these parameterizations in global and regional models. To test recently developed prognostic parameterizations based on detailed cloud microphysics, we have first compared single-column model (SCM) output with ARM observations at the Southern Great Plains (SGP), North Slope of Alaska (NSA) and Topical Western Pacific (TWP) sites. We focus on the predicted cloud amounts and on a suite of radiative quantities strongly dependent on clouds, such as downwelling surface shortwave radiation. Our results demonstrate the superiority of parameterizations based on comprehensive treatments of cloud microphysics and cloud-radiative interactions. At the SGP and NSA sites, the SCM results simulate the ARM measurements well and are demonstrably more realistic than typical parameterizations found in conventional operational forecasting models. At the TWP site, the model performance depends strongly on details of the scheme, and the results of our diagnostic tests suggest ways to develop improved parameterizations better suited to simulating cloud-radiation interactions in the tropics generally. These advances have made it possible to take the next step and build on this progress, by incorporating our parameterization schemes in state-of-the-art 3D atmospheric models, and diagnosing and evaluating the results using independent data. Because the improved cloud-radiation results have been obtained largely via implementing detailed and physically comprehensive cloud microphysics, we anticipate that improved predictions of hydrologic cycle components, and hence of precipitation, may also be achievable. We are currently testing the performance of our ARM-based parameterizations in state-of-the--art global and regional

  10. Atmospheric Radiation Measurement Program Plan

    International Nuclear Information System (INIS)

    1990-02-01

    In order to understand energy's role in anthropogenic global climate change, significant reliance is being placed on General Circulation Models (GCMs). A major goal of the Department is to foster the development of GCMs capable of predicting the timing and magnitude of greenhouse gas-induced global warming and the regional effects of such warming. DOE research has revealed that cloud radiative feedback is the single most important effect determining the magnitude of possible climate responses to human activity. However, cloud radiative forcing and feedbacks are not understood at the levels needed for reliable climate prediction. The Atmospheric Radiation Measurement (ARM) Program will contribute to the DOE goal by improving the treatment of cloud radiative forcing and feedbacks in GCMs. Two issues will be addressed: the radiation budget and its spectral dependence and the radiative and other properties of clouds. Understanding cloud properties and how to predict them is critical because cloud properties may very well change as climate changes. The experimental objective of the ARM Program is to characterize empirically the radiative processes in the Earth's atmosphere with improved resolution and accuracy. A key to this characterization is the effective treatment of cloud formation and cloud properties in GCMs. Through this characterization of radiative properties, it will be possible to understand both the forcing and feedback effects. GCM modelers will then be able to better identify the best approaches to improved parameterizations of radiative transfer effects. This is expected to greatly improve the accuracy of long-term, GCM predictions and the efficacy of those predictions at the important regional scale, as the research community and DOE attempt to understand the effects of greenhouse gas emissions on the Earth's climate. 153 refs., 24 figs., 6 tabs

  11. The Development of light-weight 2-link robot arm for high radiation area

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Cheol; Seo, Yong Chil; Jung, Kyung Min; Choi, Young Soo

    2009-10-15

    A light-weight 2-link robot arm which weight is less than 8kg was developed for treating the small radio-active material in the high radiation area such as nuclear power plants and NDT area. The light-weight 2-link robot arm can be attached on a small mobile robot and carry out tasks. It is a 5 DOF robot arm including a gripper

  12. A Climatology of Surface Cloud Radiative Effects at the ARM Tropical Western Pacific Sites

    Energy Technology Data Exchange (ETDEWEB)

    McFarlane, Sally A.; Long, Charles N.; Flaherty, Julia E.

    2013-04-01

    Cloud radiative effects on surface downwelling fluxes are investigated using long-term datasets from the three Atmospheric Radiation Measurement (ARM) sites in the Tropical Western Pacific (TWP) region. The Nauru and Darwin sites show significant variability in sky cover, downwelling radiative fluxes, and surface cloud radiative effect (CRE) due to El Niño and the Australian monsoon, respectively, while the Manus site shows little intra-seasonal or interannual variability. Cloud radar measurement of cloud base and top heights are used to define cloud types so that the effect of cloud type on the surface CRE can be examined. Clouds with low bases contribute 71-75% of the surface shortwave (SW) CRE and 66-74% of the surface longwave (LW) CRE at the three TWP sites, while clouds with mid-level bases contribute 8-9% of the SW CRE and 12-14% of the LW CRE, and clouds with high bases contribute 16-19% of the SW CRE and 15-21% of the LW CRE.

  13. Instrument development for atmospheric radiation measurement (ARM): Status of the Atmospheric Emitted Radiance Interferometer - extended Resolution (AERI-X), the Solar Radiance Transmission Interferometer (SORTI), and the Absolute Solar Transmission Inferometer (ASTI)

    Energy Technology Data Exchange (ETDEWEB)

    Murcray, F.; Stephen, T.; Kosters, J. [Univ. of Denver, CO (United States)

    1996-04-01

    This paper describes three instruments currently under developemnt for the Atmospheric Radiation Measurement (ARM) Program at the University of Denver: the AERI-X (Atmospheric Emitted Radiance Interferometer-Extended Resolution) and the SORTI (Solar R adiance Transmission Interferometer), and ASTI (Absolute Solar transmission Interferometer).

  14. Preliminary Findings from the One-Year Electric Field Study in the North Slope of Alaska (OYES-NSA), Atmospheric Radiation Measurement (ARM) Field Campaign

    Science.gov (United States)

    Lavigne, T.; Liu, C.

    2017-12-01

    Previous studies focusing on the comparison of the measured electric field to the physical properties of global electrified clouds have been conducted almost exclusively in the Southern Hemisphere. The One-Year Electric Field Study-North Slope of Alaska (OYES-NSA) aims to establish a long-running collection of this valuable electric field data in the Northern Hemisphere. Presented here is the six-month preliminary data and results of the OYES-NSA Atmospheric Radiation Mission (ARM) field campaign. The local electric field measured in Barrow, Alaska using two CS110 reciprocating shutter field meters, has been compared to simultaneous measurements from the ARM Ka-Band zenith radar, to better understand the influence and contribution of different types of clouds on the local electric field. The fair-weather electric field measured in Barrow has also been analyzed and compared to the climatology of electric field at Vostok Station, Antarctica. The combination of the electric field dataset in the Northern Hemisphere, alongside the local Ka cloud radar, global Precipitation Feature (PF) database, and quasi-global lightning activity (55oN-55oS), allows for advances in the physical understanding of the local electric field, as well as the Global Electric Circuit (GEC).

  15. ARM Mentor Selection Process

    Energy Technology Data Exchange (ETDEWEB)

    Sisterson, D. L. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-10-01

    The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud formation processes and their influence on radiative transfer. In 2003, the ARM Program became a national scientific user facility, known as the ARM Climate Research Facility. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, also known as lead mentors. Lead mentors must have an excellent understanding of in situ and remote-sensing instrumentation theory and operation and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Climate Research Facility is seeking the best overall qualified candidate who can fulfill lead mentor requirements in a timely manner.

  16. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  17. Intraoperative radiation exposure in spinal scoliosis surgery for pediatric patients using the O-arm® imaging system.

    Science.gov (United States)

    Kobayashi, Kazuyoshi; Ando, Kei; Ito, Kenyu; Tsushima, Mikito; Morozumi, Masayoshi; Tanaka, Satoshi; Machino, Masaaki; Ota, Kyotaro; Ishiguro, Naoki; Imagama, Shiro

    2018-05-01

    The O-arm ® navigation system allows intraoperative CT imaging that can facilitate highly accurate instrumentation surgery, but radiation exposure is higher than with X-ray radiography. This is a particular concern in pediatric surgery. The purpose of this study is to examine intraoperative radiation exposure in pediatric spinal scoliosis surgery using O-arm. The subjects were 38 consecutive patients (mean age 12.9 years, range 10-17) with scoliosis who underwent spinal surgery with posterior instrumentation using O-arm. The mean number of fused vertebral levels was 11.0 (6-15). O-arm was performed before and after screw insertion, using an original protocol for the cervical, thoracic, and lumbar spine doses. The average scanning range was 6.9 (5-9) intervertebral levels per scan, with 2-7 scans per patient (mean 4.0 scans). Using O-arm, the dose per scan was 92.5 (44-130) mGy, and the mean total dose was 401 (170-826) mGy. This dose was 80.2% of the mean preoperative CT dose of 460 (231-736) mGy (P = 0.11). The total exposure dose and number of scans using intraoperative O-arm correlated strongly and significantly with the number of fused levels; however, there was no correlation with the patient's height. As the fused range became wider, several scans were required for O-arm, and the total radiation exposure became roughly the same as that in preoperative CT. Use of O-arm in our original protocol can contribute to reduction in radiation exposure.

  18. DEVELOPMENT OF IMPROVED TECHNIQUES FOR SATELLITE REMOTE SENSING OF CLOUDS AND RADIATION USING ARM DATA, FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Minnis, Patrick [NASA Langley Research Center, Hampton, VA

    2013-06-28

    During the period, March 1997 – February 2006, the Principal Investigator and his research team co-authored 47 peer-reviewed papers and presented, at least, 138 papers at conferences, meetings, and workshops that were supported either in whole or in part by this agreement. We developed a state-of-the-art satellite cloud processing system that generates cloud properties over the Atmospheric Radiation (ARM) surface sites and surrounding domains in near-real time and outputs the results on the world wide web in image and digital formats. When the products are quality controlled, they are sent to the ARM archive for further dissemination. These products and raw satellite images can be accessed at http://cloudsgate2.larc.nasa.gov/cgi-bin/site/showdoc?docid=4&cmd=field-experiment-homepage&exp=ARM and are used by many in the ARM science community. The algorithms used in this system to generate cloud properties were validated and improved by the research conducted under this agreement. The team supported, at least, 11 ARM-related or supported field experiments by providing near-real time satellite imagery, cloud products, model results, and interactive analyses for mission planning, execution, and post-experiment scientific analyses. Comparisons of cloud properties derived from satellite, aircraft, and surface measurements were used to evaluate uncertainties in the cloud properties. Multiple-angle satellite retrievals were used to determine the influence of cloud structural and microphysical properties on the exiting radiation field.

  19. [Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system].

    Science.gov (United States)

    Grelat, M; Zairi, F; Quidet, M; Marinho, P; Allaoui, M; Assaker, R

    2015-08-01

    Transforaminal lumbar interbody fusion with a minimally invasive approach (MIS TLIF) has become a very popular technique in the treatment of degenerative diseases of the lumbar spine, as it allows a decrease in muscle iatrogenic. However, iterative radiological controls inherent to this technique are responsible for a significant increase in exposure to ionizing radiation for the surgeon. New techniques for radiological guidance (O-arm navigation-assisted) would overcome this drawback, but this remains unproven. To analyze the exposure of the surgeon to intraoperative X-ray during a MIS TLIF under fluoroscopy and under O-arm navigation-assisted. This prospective study was conducted at the University Hospital of Lille from February to May 2013. Twelve patients underwent a MIS TLIF for the treatment of low-grade spondylolisthesis; six under standard fluoroscopy (group 1) and six under O-arm system (group 2). Passive dosimeters (rings and glasses) and active dosimeters for thorax were used to measure the radiation exposure of the surgeon. For group 1, the average time of fluoroscopy was 3.718 minutes (3.13-4.56) while no radioscopy was perform on group 2. For the first group, the average exposure dose was 12 μSv (5-20 μSv) on the thorax, 1168 μSv (510-2790 μSv) on the main hand and 179 μSv (103-486 μSv) on the lens. The exposure dose was measured zero on the second group. The maximum recommended doses can be reached, mainly for the lens. In addition to the radioprotection measures, O-arm navigation systems are safe alternatives to significantly reduce surgeon exposure. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. DOE ASR Final Report on “Use of ARM Observations to Investigate the Role of Tropical Radiative Processes and Cloud Radiative Effects in Climate Simulations”

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qiang [Univ. of Washington, Seattle, WA (United States). Dept. of Atmospheric Sciences; Comstock, Jennifer [Univ. of Washington, Seattle, WA (United States). Dept. of Atmospheric Sciences

    2018-01-29

    The overall objective of this ASR funded project is to investigate the role of cloud radiative effects, especially those associated with tropical thin cirrus clouds in the tropical tropopause layer, by analyzing the ARM observations combined with numerical models. In particular, we have processed and analyzed the observations from the Raman lidar at the ARM SGP and TWP sites. In the tenure of the project (8/15/2013 – 8/14/2016 and with a no-cost extension to 8/14/2017), we have been concentrating on (i) developing an automated feature detection scheme of clouds and aerosols for the ARM Raman lidar; (ii) developing an automated retrieval of cloud and aerosol extinctions for the ARM Raman lidar; (iii) investigating cloud radiative effects based on the observations on the simulated temperatures in the tropical tropopause layer using a radiative-convective model; and (iv) examining the effect of changes of atmospheric composition on the tropical lower-stratospheric temperatures. In addition, we have examined the biases in the CALIPSO-inferred aerosol direct radiative effects using ground-based Raman lidars at the ARM SGP and TWP sites, and estimated the impact of lidar detection sensitivity on assessing global aerosol direct radiative effects. We have also investigated the diurnal cycle of clouds and precipitation at the ARM site using the cloud radar observations along with simulations from the multiscale modeling framework. The main results of our research efforts are reported in the six referred journal publications that acknowledge the DOE Grant DE-SC0010557.

  1. Data systems for science integration within the Atmospheric Radiation Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Gracio, D.K.; Hatfield, L.D.; Yates, K.R.; Voyles, J.W. [Pacific Northwest Lab., Richland, WA (United States); Tichler, J.L. [Brookhaven National Lab., Upton, NY (United States); Cederwall, R.T.; Laufersweiler, M.J.; Leach, M.J. [Lawrence Livermore National Lab., CA (United States); Singley, P. [Oak Ridge National Lab., TN (United States)

    1995-12-31

    The Atmospheric Radiation Measurement (ARM) Program was developed by the US Department of Energy to support the goals and mission of the US Global Change Research Program. The purpose of the ARM program is to improve the predictive capabilities of General Circulation Models (GCMs) in their treatment of clouds and radiative transfer effects. Three experimental testbeds were designed for the deployment of instruments to collect atmospheric data used to drive the GCMs. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in early 1996 in the Tropical Western Pacific (TWP) and in 1997 on the North Slope of Alaska (NSA). Approximately 1.5 GB of data are transferred per day via the Internet from the CART sites, and external data sources to the ARM Experiment Center (EC) at Pacific Northwest Laboratory in Richland, Washington. The Experimental Center is central to the ARM data path and provides for the collection, processing, analysis and delivery of ARM data. Data from the CART sites from a variety of instrumentation, observational systems and from external data sources are transferred to the Experiment Center. The EC processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while maintaining a three-month running archive of data.

  2. Data management and scientific integration within the Atmospheric Radiation Measurement Program

    Science.gov (United States)

    Gracio, Deborah K.; Hatfield, Larry D.; Yates, Kenneth R.; Voyles, Jimmy W.; Tichler, Joyce L.; Cederwall, Richard T.; Laufersweiler, Mark J.; Leach, Martin J.; Singley, Paul

    1995-01-01

    The Atmospheric Radiation Measurement (ARM) Program has been developed by the U.S. Department of Energy with the goal to improve the predictive capabilities of General Circulation Models (GCM's) in their treatment of clouds and radiative transfer effects. To achieve this goal, three experimental testbeds were designed for the deployment of instruments that will collect atmospheric data used to drive the GCM's. Each site, known as a Cloud and Radiation Testbed (CART), consists of a highly available, redundant data system for the collection of data from a variety of instrumentation. The first CART site was deployed in April 1992 in the Southern Great Plains (SGP), Lamont, Oklahoma, with the other two sites to follow in September 1995 in the Tropical Western Pacific and in 1997 on the North Slope of Alaska. Approximately 400 MB of data are transferred per day via the Internet from the SGP site to the ARM Experiment Center at Pacific Northwest Laboratory in Richland, Washington. The Experiment Center is central to the ARM data path and provides for the collection, processing, analysis, and delivery of ARM data. Data are received from the CART sites from a variety of instrumentation, observational systems, amd external data sources. The Experiment Center processes these data streams on a continuous basis to provide derived data products to the ARM Science Team in near real-time while providing a three-month running archive of data. A primary requirement of the ARM Program is to preserve and protect all data produced or acquired. This function is performed at Oak Ridge National Laboratory where leading edge technology is employed for the long-term storage of ARM data. The ARM Archive provides access to data for participation outside of the ARM Program. The ARM Program involves a collaborative effort by teams from various DOE National Laboratories, providing multi-disciplinary areas of expertise. This paper will discuss the collaborative methods in which the ARM teams

  3. Radiation measurements and applications

    International Nuclear Information System (INIS)

    Griffin, H.C.; Rogers, W.L.

    1990-01-01

    This 1990 symposium was the seventh in a series of meetings which began in 1964. The 300 participants from 23 countries and the 65 oral and 77 poster presentations were more than double the size of the 1985 symposium. Some of this increase derived from the broadened scope of the program. Previous meetings emphasized X-rays and gamma-rays, but it has been increasingly clear that distinction from other forms of radiation (i.e., electrons, alpha-particles and neutrons) was contrived. This broadening led to papers in fields such as ''airport'' monitors and arms control. However, most of the increase in size of the symposium is simply a reflection of the vigorous activity, both academic and industrial in radiation measurements and their many applications. The papers in these Proceedings are arranged by major topic without regard to whether the paper was invited or contributed, oral or poster. Discussion, although an important part of the meeting, was not recorded and therefore is not included in the Proceedings

  4. ARM Climate Research Facility Annual Report 2005

    Energy Technology Data Exchange (ETDEWEB)

    J. Voyles

    2005-12-31

    Through the ARM Program, the DOE funded the development of several highly instrumented ground stations for studying cloud formation processes and their influence on radiative transfer, and for measuring other parameters that determine the radiative properties of the atmosphere. This scientific infrastructure, and resultant data archive, is a valuable national and international asset for advancing scientific knowledge of Earth systems. In fiscal year (FY) 2003, the DOE designated ARM sites as a national scientific user facility: the ARM Climate Research (ACRF). The ACRF has enormous potential to contribute to a wide range interdisciplinary science in areas such as meteorology, atmospheric aerosols, hydrology, biogeochemical cycling, and satellite validation, to name only a few.

  5. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  6. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris, E-mail: boris.schell@googlemail.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Heidenreich, Ralf, E-mail: ralf.heidenreich@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Heidenreich, Monika, E-mail: info@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Thalhammer, Axel, E-mail: axel.thalhammer@kgu.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Naeem, Naguib Nagy Naguib, E-mail: nagynnn@yahoo.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas Josef, E-mail: T.Vogl@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Zangos, Stefan, E-mail: Zangos@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany)

    2012-12-15

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  7. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    Science.gov (United States)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  8. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    International Nuclear Information System (INIS)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-01-01

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  9. Characteristics and direct radiative effect of mid-latitude continental aerosols: the ARM case

    Directory of Open Access Journals (Sweden)

    M. G. Iziomon

    2003-01-01

    Full Text Available A multi-year field measurement analysis of the characteristics and direct radiative effect of aerosols at the Southern Great Plains (SGP central facility of the Atmospheric Radiation Measurement (ARM Program is presented. Inter-annual mean and standard deviation of submicrometer scattering fraction (at 550 nm and Ångström exponent å (450 nm, 700 nm at the mid-latitude continental site are indicative of the scattering dominance of fine mode aerosol particles, being 0.84±0.03 and 2.25±0.09, respectively. We attribute the diurnal variation of submicron aerosol concentration to coagulation, photochemistry and the evolution of the boundary layer. Precipitation does not seem to play a role in the observed afternoon maximum in aerosol concentration. Submicron aerosol mass at the site peaks in the summer (12.1±6.7mg m-3, with the summer value being twice that in the winter. Of the chemically analyzed ionic components (which exclude carbonaceous aerosols, SO4= and NH4+ constitute the dominant species at the SGP seasonally, contributing 23-30% and 9-12% of the submicron aerosol mass, respectively. Although a minor species, there is a notable rise in NO3- mass fraction in winter. We contrast the optical properties of dust and smoke haze. The single scattering albedo w0 shows the most remarkable distinction between the two aerosol constituents. We also present aircraft measurements of vertical profiles of aerosol optical properties at the site. Annually, the lowest 1.2 km contributes 70% to the column total light scattering coefficient. Column-averaged and surface annual mean values of hemispheric backscatter fraction (at 550 nm, w0 (at 550 nm and å (450 nm, 700 nm agree to within 5% in 2001. Aerosols produce a net cooling (most pronounced in the spring at the ARM site

  10. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  11. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  12. "Radiative Closure Studies for Clear Skies During the ARM 2003 Aerosol Intensive Observation Period"

    Energy Technology Data Exchange (ETDEWEB)

    J. J. Michalsky, G. P. Anderson, J. Barnard, J. Delamere, C. Gueymard, S. Kato, P. Kiedron, A. McComiskey, and P. Ricchiazzi

    2006-04-01

    The Department of Energy's Atmospheric Radiation Measurement (ARM) program sponsored a large intensive observation period (IOP) to study aerosol during the month of May 2003 around the Southern Great Plains (SGP) Climate Research Facility (CRF) in north central Oklahoma. Redundant measurements of aerosol optical properties were made using different techniques at the surface as well as in vertical profile with sensors aboard two aircraft. One of the principal motivations for this experiment was to resolve the disagreement between models and measurements of diffuse horizontal broadband shortwave irradiance at the surface, especially for modest aerosol loading. This paper focuses on using the redundant aerosol and radiation measurements during this IOP to compare direct beam and diffuse horizontal broadband shortwave irradiance measurements and models at the surface for a wide range of aerosol cases that occurred during 30 clear-sky periods on 13 days of May 2003. Models and measurements are compared over a large range of solar-zenith angles. Six different models are used to assess the relative agreement among them and the measurements. Better agreement than previously achieved appears to be the result of better specification of input parameters and better measurements of irradiances than in prior studies. Biases between modeled and measured direct irradiances are less than 1%, and biases between modeled and measured diffuse irradiances are less than 2%.

  13. Level of Agreement Between Forearm and Upper Arm Blood Pressure Measurements in Patients With Large Arm Circumference.

    Science.gov (United States)

    Watson, Sheri; Aguas, Marita; Colegrove, Pat; Foisy, Nancy; Jondahl, Bonnie; Anastas, Zoe

    2017-02-01

    The purpose of the study was to determine if forearm blood pressures (BPs) measured in three different locations agree with the recommended upper arm location for noninvasive BP measurement. A method-comparison design was used. In a convenience sample of postanesthesia care unit patients with large upper arm circumference, BP's were obtained in three different forearm locations (lower forearm, middle forearm, and upper forearm) and compared to upper arm BP using an automated BP measuring device. The level of agreement (bias ± precision) between each forearm location and the upper arm BP was calculated using standard formulas. Acceptable levels of agreement based on expert opinion were set a priori at bias and precision values of less than ±5 mm Hg (bias) and ±8 mm Hg (precision). Forty-eight postanesthesia patients participated in the study. Bias and precision values were found to exceed the acceptable level of agreement for all but one of the systolic and diastolic BP comparisons in the three forearm BP locations. Fifty-six percent of all patients studied had one or more BP difference of at least 10 mm Hg in each of the three forearm locations, with 10% having one or more differences of at least 20 mm Hg. The differences in forearm BP measurements observed in this study indicate that the clinical practice of using a forearm BP with a regular-sized BP cuff in place of a larger sized BP cuff placed on the upper arm in postanesthesia care unit patients with large arm circumferences is inappropriate. The BPs obtained at the forearm location are not equivalent to the BPs obtained at the upper arm location. Copyright © 2015 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  14. Unequal-Arms Michelson Interferometers

    Science.gov (United States)

    Tinto, Massimo; Armstrong, J. W.

    2000-01-01

    Michelson interferometers allow phase measurements many orders of magnitude below the phase stability of the laser light injected into their two almost equal-length arms. If, however, the two arms are unequal, the laser fluctuations can not be removed by simply recombining the two beams. This is because the laser jitters experience different time delays in the two arms, and therefore can not cancel at the photo detector. We present here a method for achieving exact laser noise cancellation, even in an unequal-arm interferometer. The method presented in this paper requires a separate readout of the relative phase in each arm, made by interfering the returning beam in each arm with a fraction of the outgoing beam. By linearly combining the two data sets with themselves, after they have been properly time shifted, we show that it is possible to construct a new data set that is free of laser fluctuations. An application of this technique to future planned space-based laser interferometer detector3 of gravitational radiation is discussed.

  15. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  16. Atmospheric Radiation Measurement Climate Research Facility Operations Quarterly Report October 1-December 31, 2016

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-01-01

    Individual datastreams from instrumentation at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research observatories (sites) are collected and routed to the ARM Data Center (ADC). The Data Management Facility (DMF), a component of the ADC, executes datastream processing in near-real time. Processed data are then delivered approximately daily to the ARM Data Archive, also a component of the ADC, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archive to the expected number of data records. DOE requires national user facilities to report time-based operating data.

  17. MPL-net at ARM Sites

    Science.gov (United States)

    Spinhirne, J. D.; Welton, E. J.; Campbell, J. R.; Berkoff, T. A.; Starr, David OC. (Technical Monitor)

    2002-01-01

    The NASA MPL-net project goal is consistent data products of the vertical distribution of clouds and aerosol from globally distributed lidar observation sites. The four ARM micro pulse lidars are a basis of the network to consist of over twelve sites. The science objective is ground truth for global satellite retrievals and accurate vertical distribution information in combination with surface radiation measurements for aerosol and cloud models. The project involves improvement in instruments and data processing and cooperation with ARM and other partners.

  18. Obesity predicts for arm edema in conservatively treated breast cancer patients

    International Nuclear Information System (INIS)

    Werner, R.S.; McCormick, B.; Gray, J.R.; Cox, L.; Cirrincione, C.; Petrek, J.A.; Yahalom, J.

    1990-01-01

    This paper identifies risk factors for arm edema (AE) following breast-conserving surgery and radiation therapy. Upper and lower arm circumferences were measured at interval follow-up visits in 284 patients. A different of 2.5 cm or more in either measurement (treated vs untreated arms) defined AE. Possible predictors for AE examined by univariate and multivariate analysis included level of dissection; number of nodes removed; number involved; tumor size and location; use of supraclavicular fields; patient age, weight, and size (tangent separation measurement); and systemic therapy

  19. Atmospheric Radiation Measurement Madden-Julian Oscillation Investigation Experiment Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Long, Chuck [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.

    2016-07-01

    Every 30–90 days during the Northern Hemisphere winter, the equatorial tropical atmosphere experiences pulses of extraordinarily strong deep convection and rainfall. This phenomenon is referred to as the Madden–Julian Oscillation, or MJO, named after the scientists who identified this cycle. The MJO significantly affects weather and rainfall patterns around the world (Zhang 2013). To improve predictions of the MJO—especially about how it forms and evolves throughout its lifecycle—an international group of scientists collected an unprecedented set of observations from the Indian Ocean and western Pacific region from October 2011 through March 2012 through several coordinated efforts. The coordinated field campaigns captured six distinct MJO cycles in the Indian Ocean. The rich set of observations capturing several MJO events from these efforts will be used for many years to study the physics of the MJO. Here we highlight early research results using data from the Atmospheric Radiation Measurement (ARM) Madden-Julian Oscillation Investigation Experiment (AMIE), sponsored by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility.

  20. ARM West Antarctic Radiation Experiment (AWARE) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, Daniel [Univ. of California, San Diego, CA (United States). Scripps Inst. of Oceanography; Bromwich, David H [Ohio State University; Vogelmann, Andrew M [Brookhaven National Lab. (BNL), Upton, NY (United States); Verlinde, Johannes [Pennsylvania State Univ., University Park, PA (United States); Russell, Lynn M [Univ. of California, San Diego, CA (United States). Scripps Inst. of Oceanography

    2017-09-15

    The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) is the most technologically advanced atmospheric and climate science campaign yet fielded in Antarctica. AWARE was motivated be recent concern about the impact of cryospheric mass loss on global sea level rise. Specifically, the West Antarctic Ice Sheet (WAIS) is now the second largest contributor to rising sea level, after the Greenland Ice Sheet. As steadily warming ocean water erodes the grounding lines of WAIS components where they meet the Amundsen and Bellingshausen Seas, the retreating grounding lines moving inland and downslope on the underlying terrain imply mechanical instability of the entire WAIS. There is evidence that this point of instability may have already been reached, perhaps signifying more rapid loss of WAIS ice mass. At the same time, the mechanical support provided by adjacent ice shelves, and also the fundamental stability of exposed ice cliffs at the ice sheet grounding lines, will be adversely impacted by a warming atmosphere that causes more frequent episodes of surface melting. The surface meltwater damages the ice shelves and ice cliffs through hydrofracturing. With the increasing concern regarding these rapid cryospheric changes, AWARE was motivated by the need to (a) diagnose the surface energy balance in West Antarctica as related to both summer season climatology and potential surface melting, and (b) improve global climate model (GCM) performance over Antarctica, such that future cryospheric projections can be more reliable.

  1. MAGIC: Marine ARM GPCI Investigation of Clouds

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, ER; Wiscombe, WJ; Albrecht, BA; Bland, GL; Flagg, CN; Klein, SA; Kollias, P; Mace, G; Reynolds, RM; Schwartz, SE; Siebesma, AP; Teixeira, J; Wood, R; Zhang, M

    2012-10-03

    The second Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF2) will be deployed aboard the Horizon Lines cargo container ship merchant vessel (M/V) Spirit for MAGIC, the Marine ARM GPCI1 Investigation of Clouds. The Spirit will traverse the route between Los Angeles, California, and Honolulu, Hawaii, from October 2012 through September 2013 (except for a few months in the middle of this time period when the ship will be in dry dock). During this field campaign, AMF2 will observe and characterize the properties of clouds and precipitation, aerosols, and atmospheric radiation; standard meteorological and oceanographic variables; and atmospheric structure. There will also be two intensive observational periods (IOPs), one in January 2013 and one in July 2013, during which more detailed measurements of the atmospheric structure will be made.

  2. Science team participation in the ARM program

    International Nuclear Information System (INIS)

    Cess, R.D.

    1993-01-01

    This progress report discusses the Science Team participation in the Atmospheric Radiation Measurement (ARM) Program for the period of October 31, 1992 to November 1, 1993. This report summarized the research accomplishments of six papers

  3. Final report for the project "Improving the understanding of surface-atmosphere radiative interactions by mapping surface reflectance over the ARM CART site" (award DE-FG02-02ER63351)

    Energy Technology Data Exchange (ETDEWEB)

    Alexander P. Trishchenko; Yi Luo; Konstantin V. Khlopenkov, William M. Park; Zhanqing Li; Maureen Cribb

    2008-11-28

    Surface spectral reflectance (albedo) is a fundamental variable affecting the transfer of solar radiation and the Earth’s climate. It determines the proportion of solar energy absorbed by the surface and reflected back to the atmosphere. The International Panel on Climate Change (IPCC) identified surface albedo among key factors influencing climate radiative forcing. Accurate knowledge of surface reflective properties is important for advancing weather forecasting and climate change impact studies. It is also important for determining radiative impact and acceptable levels of greenhouse gases in the atmosphere, which makes this work strongly linked to major scientific objectives of the Climate Change Research Division (CCRD) and Atmospheric Radiation Measurement (ARM) Program. Most significant accomplishments of eth project are listed below. I) Surface albedo/BRDF datasets from 1995 to the end of 2004 have been produced. They were made available to the ARM community and other interested users through the CCRS public ftp site ftp://ftp.ccrs.nrcan.gc.ca/ad/CCRS_ARM/ and ARM IOP data archive under “PI data Trishchenko”. II) Surface albedo properties over the ARM SGP area have been described for 10-year period. Comparison with ECMWF data product showed some deficiencies in the ECMWF surface scheme, such as missing some seasonal variability and no dependence on sky-conditions which biases surface energy budget and has some influence of the diurnal cycle of upward radiation and atmospheric absorption. III) Four surface albedo Intensive Observation Period (IOP) Field Campaigns have been conducted for every season (August, 2002, May 2003, February 2004 and October 2004). Data have been prepared, documented and transferred to ARM IOP archive. Nine peer-reviewed journal papers and 26 conference papers have been published.

  4. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  5. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  6. Passive detection of nuclear-armed SLCMs

    International Nuclear Information System (INIS)

    Sagdeev, R.Z.; Prilutsky, O.F.; Frolov, V.A.

    1992-01-01

    Effective procedures have been developed, using national technical measures (photoreconnaissance satellites, radiointercept stations, etc.), for verification of reductions in land-based intercontinental ballistic missiles, such as marine-based ballistic missiles, and strategic bombers. However, there is agreement on procedures for verifying limitations of numbers of long-range nuclear-armed cruise missiles. The difficulties in developing such procedures are sometimes regarded (by opponents of nuclear disarmament) as a reason why cruise missiles based on ships and submarines ought not to be limited by future arms-reduction treaties. This paper considers the detectability of nuclear-armed cruise missiles through the penetrating radiation emitted spontaneously from their warheads

  7. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  8. Radiation practices and radiation measurements

    International Nuclear Information System (INIS)

    2008-03-01

    The guide presents the principal requirements on accuracy of radiation measurements and on the approval, calibration and operating condition inspections of radiation meters, together with requirements for dosimetric services measuring the individual radiation doses of workers engaged in radiation work (approved dosimetric services). The Guide also sets out the definitions of quantities and units used in radiation measurements. The radiation protection quantities used for assessing the harmful effects of radiation and for expressing the maximum values for radiation exposure (equivalent dose and effective dose) are set out in Guide ST 7.2. This Guide concerns measurements of ionizing radiation involved in radiation practices, the results of which are used for determining the radiation exposure of workers engaged in radiation work and members of the public, and of patients subject to the use of radiation in health services, or upon the basis of which compliance with safety requirements of appliances currently in use and of their premises of use or of the workplaces of workers is ensured. The Guide also concerns measurements of the radon concentration of inhaled air in both workplaces and dwellings. The Guide does not apply to determining the radiation exposure of aircrews, determination of exposure caused by internal radiation, or measurements made to protect the public in the event of, or in preparation for abnormal radiation conditions

  9. Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm

    Directory of Open Access Journals (Sweden)

    Yang-Sub Lee

    2015-01-01

    Full Text Available Background: The aim of this study was to investigate clinical applications of mobile C-arms and consequent radiation risk, to increase medical attention on radiation protection, and to provide basic data for safe radiation use in the operating room. Materials and Methods: In this study, a total of 374 surgical operations, conducted using a portable fluoroscopic X-ray system from January to March of 2013, were analyzed. Dose summaries produced by the General Electric C-arm and data elements in digital imaging and communications in the medicine header of Ziehm C-arm, fluoroscopy time were used to obtain dose-area product (DAP and effective dose. Corresponding mean and maximum values were calculated, and the resulting data on the frequency of application, fluoroscopy time, DAP, and effective dose were compared and analyzed in terms of surgical specialty and operation types. Results: Orthopedic surgery was the most frequent with 165 cases (44.1%. The highest DAP value and effective dose were found in liver transplant among surgical specialty fields, with mean values of 2.90 ± 3.76 mGy∙m 2 and 58 ± 75.2 mSv, respectively (P = 0.0001. The highest DAP value and effective dose were observed in intra-operative mesenteric portography among types of surgery, showing mean values of 2.90 ± 3.81 mGy∙m 2 and 58.03 ± 76.24 mSv, respectively (P = 0.0001. Conclusion: Because DAP varies significantly across surgical specialties and types of operation, aggressive efforts to understand the effects of radiation dose is critical for radiation protection from intra-operative use of mobile C-arms.

  10. A Climatology of Midlatitude Continental Clouds from the ARM SGP Site. Part II; Cloud Fraction and Surface Radiative Forcing

    Science.gov (United States)

    Xi, B.; Minnis, P.

    2006-01-01

    Data collected at the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Central Facility (SCF) are analyzed to determine the monthly and hourly variations of cloud fraction and radiative forcing between January 1997 and December 2002. Cloud fractions are estimated for total cloud cover and for single-layered low (0-3 km), middle (3-6 km), and high clouds (more than 6 km) using ARM SCG ground-based paired lidar-radar measurements. Shortwave (SW) and longwave (LW) fluxes are derived from up- and down-looking standard precision spectral pyranometers and precision infrared radiometer measurements with uncertainties of approximately 10 Wm(exp -2). The annual averages of total, and single-layered low, middle and high cloud fractions are 0.49, 0.11, 0.03, and 0.17, respectively. Both total and low cloud amounts peak during January and February and reach a minimum during July and August, high clouds occur more frequently than other types of clouds with a peak in summer. The average annual downwelling surface SW fluxes for total and low clouds (151 and 138 Wm(exp-2), respectively) are less than those under middle and high clouds (188 and 201 Wm(exp -2), respectively), but the downwelling LW fluxes (349 and 356 Wm(exp -2)) underneath total and low clouds are greater than those from middle and high clouds (337 and 333 Wm(exp -2)). Low clouds produce the largest LW warming (55 Wm(exp -2) and SW cooling (-91 Wm(exp -2)) effects with maximum and minimum absolute values in spring and summer, respectively. High clouds have the smallest LW warming (17 Wm(exp -2)) and SW cooling (-37 Wm(exp -2)) effects at the surface. All-sky SW CRF decreases and LW CRF increases with increasing cloud fraction with mean slopes of -0.984 and 0.616 Wm(exp -2)%(exp -1), respectively. Over the entire diurnal cycle, clouds deplete the amount of surface insolation more than they add to the downwelling LW flux. The calculated CRFs do not appear to be significantly

  11. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  12. Inconsistency between simultaneous blood pressure measurements in the arm, forearm, and leg in anesthetized children.

    Science.gov (United States)

    Keidan, Ilan; Sidi, Avner; Ben-Menachem, Erez; Tene, Yael; Berkenstadt, Haim

    2014-02-01

    To determine the accuracy and precision of simultaneous noninvasive blood pressure (NIBP) measurement in the arm, forearm, and ankle in anesthetized children. Prospective, randomized study. University medical center. 101 ASA physical status 1 and 2 children (aged 1-8 yrs) scheduled for elective surgery with general anesthesia. Simultaneous NIBP measurements were recorded at the arm, forearm, and ankle at 5-minute intervals. The systolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 63% and 29% of measurements, and within the ± 20% range in 85% and 67% of measurements, respectively. The diastolic blood pressure difference between the arm-forearm or the arm-ankle was within the ± 10% range in 42% and 44% and within the ± 20% range in 67% and 74% of measurements, respectively. In patients in whom the initial three NIBP measurements were within the ± 20% range between the forearm and arm, 86% of the subsequent measurements were also within that limit. Forearm and ankle NIBP measurements are unreliable and inconsistent with NIBP measured in the arm of anesthetized children. These alternative BP measurement sites are not reliable in accuracy (comparison with reference "gold" standard) and precision (reproducibility). Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Measures for regional security and arms control in the South-East Asian area

    International Nuclear Information System (INIS)

    Uren, R.T.

    1992-01-01

    The subject of regional security and arms control in the South-East Asia raises some new and difficult issues. No approach to ensuring regional security could be complete without military dimension including the following categories: regional arms control; global arms control measure; confidence building measures that are designed to enhance the transparency of defense policies; confidence building measures that encourage cooperation among the military forces in the region

  14. Aeroradiometric Measurements In The Framework Of The ARM03 Exercise

    International Nuclear Information System (INIS)

    Bucher, B.; Rybach, L.; Schwarz, G.

    2004-11-01

    The annually repeated measurement flights took place in 2003 from 23 to 26 June and were focused on the bilateral exercise with the Austrian team of the Bundesministerium fuer Inneres (BMI). This exercise was held near Klagenfurt in Kaernten. Furtheron the periodically surveys in the environs of the nuclear power plants Goesgen and Muehleberg were carried out. The flights took place in the framework of the exercise ARM03 and were lead by Y. Loertscher of the Swiss National Emergency Operations Centre (NAZ). As a further activity the results of the international exercise RESUME 2002 in Scotland were compared with measurements on soil sampIes and with in situ gamma spectrometry results. This comparison shows a good agreement within the uncertainties, whereas the 137 Cs results differ the most from the measurements of soil sampIes. This is mainly caused by the different size of the area from which the measured signal is coming for airborne and ground measurements and by the different depth distributions used in the calculations. Within the bilateral exercise in Kaernten six radioactive sources of activities between 120 MBq and 50.4 GBq should be localized by airborne measurements. Two areas with those six sources in each were measured. The Austrian team was using a large volume Geiger-Mueller counter and could localize three sources in each area. Because of the additional spectral information the Swiss team could localize and identify five radioactive sources in each area. The weakest 60 Co source with an activity of 120 MBq could not be detected. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Goesgen and Muehleberg were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Goesgen couldn't be recognised on the activity maps. But the nuclear power plant Muehleberg could be identified by its direct radiation

  15. Technical progress report: Completion of spectral rotating shadowband radiometers and analysis of atmospheric radiation measurement spectral shortwave data

    Energy Technology Data Exchange (ETDEWEB)

    Michalsky, J.; Harrison, L. [State Univ. of New York, Albany, NY (United States)

    1996-04-01

    Our goal in the Atmospheric Radiation Measurement (ARM) Program is the improvement of radiation models used in general circulation models (GCMs), especially in the shortwave, (1) by providing improved shortwave radiometric measurements for the testing of models and (2) by developing methods for retrieving climatologically sensitive parameters that serve as input to shortwave and longwave models. At the Atmospheric Sciences Research Center (ASRC) in Albany, New York, we are acquiring downwelling direct and diffuse spectral irradiance, at six wavelengths, plus downwelling broadband longwave, and upwelling and downwelling broadband shortwave irradiances that we combine with National Weather Service surface and upper air data from the Albany airport as a test data set for ARM modelers. We have also developed algorithms to improve shortwave measurements made at the Southern Great Plains (SGP) ARM site by standard thermopile instruments and by the multifilter rotating shadowband radiometer (MFRSR) based on these Albany data sets. Much time has been spent developing techniques to retrieve column aerosol, water vapor, and ozone from the direct beam spectral measurements of the MFRSR. Additionally, we have had success in calculating shortwave surface albedo and aerosol optical depth from the ratio of direct to diffuse spectral reflectance.

  16. A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

    Science.gov (United States)

    Avkshtol, Vladimir; Dong, Yanqun; Hayes, Shelly B; Hallman, Mark A; Price, Robert A; Sobczak, Mark L; Horwitz, Eric M; Zaorsky, Nicholas G

    2016-01-01

    Prostate cancer is the most prevalent cancer diagnosed in men in the United States besides skin cancer. Stereotactic body radiation therapy (SBRT; 6-15 Gy per fraction, up to 45 minutes per fraction, delivered in five fractions or less, over the course of approximately 2 weeks) is emerging as a popular treatment option for prostate cancer. The American Society for Radiation Oncology now recognizes SBRT for select low- and intermediate-risk prostate cancer patients. SBRT grew from the notion that high doses of radiation typical of brachytherapy could be delivered noninvasively using modern external-beam radiation therapy planning and delivery methods. SBRT is most commonly delivered using either a traditional gantry-mounted linear accelerator or a robotic arm-mounted linear accelerator. In this systematic review article, we compare and contrast the current clinical evidence supporting a gantry vs robotic arm SBRT for prostate cancer. The data for SBRT show encouraging and comparable results in terms of freedom from biochemical failure (>90% for low and intermediate risk at 5-7 years) and acute and late toxicity (6 MV). Finally, SBRT (particularly on a gantry) may also be more cost-effective than conventionally fractionated external-beam radiation therapy. Randomized controlled trials of SBRT using both technologies are underway.

  17. ARM Climate Research Facility Quarterly Ingest Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Koontz, A. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2016-10-01

    The purpose of this report is to provide a concise status update for ingests maintained by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new ingests for which development has begun, (2) progress on existing ingests, (3) future ingests that have been recently approved, (4) other work that leads to an ingest, and (5) top requested ingests from the ARM Data Archive. New information is highlighted in blue text.

  18. ARM Climate Research Facility Quarterly Ingest Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Koontz, A. [ARM Climate Reesearch Facility, Washington, DC (United States); Sivaraman, C. [ARM Climate Reesearch Facility, Washington, DC (United States)

    2016-07-01

    The purpose of this report is to provide a concise status update for ingests maintained by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new ingests for which development has begun, (2) progress on existing ingests, (3) future ingests that have been recently approved, (4) other work that leads to an ingest, and (5) top requested ingests from the ARM Data Archive. New information is highlighted in blue text.

  19. An ARM data-oriented diagnostics package to evaluate the climate model simulation

    Science.gov (United States)

    Zhang, C.; Xie, S.

    2016-12-01

    A set of diagnostics that utilize long-term high frequency measurements from the DOE Atmospheric Radiation Measurement (ARM) program is developed for evaluating the regional simulation of clouds, radiation and precipitation in climate models. The diagnostics results are computed and visualized automatically in a python-based package that aims to serve as an easy entry point for evaluating climate simulations using the ARM data, as well as the CMIP5 multi-model simulations. Basic performance metrics are computed to measure the accuracy of mean state and variability of simulated regional climate. The evaluated physical quantities include vertical profiles of clouds, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, radiative fluxes, aerosol and cloud microphysical properties. Process-oriented diagnostics focusing on individual cloud and precipitation-related phenomena are developed for the evaluation and development of specific model physical parameterizations. Application of the ARM diagnostics package will be presented in the AGU session. This work is performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, IM release number is: LLNL-ABS-698645.

  20. ARM Climate Research Facility Annual Report 2004

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, J.

    2004-12-31

    Like a rock that slowly wears away beneath the pressure of a waterfall, planet earth?s climate is almost imperceptibly changing. Glaciers are getting smaller, droughts are lasting longer, and extreme weather events like fires, floods, and tornadoes are occurring with greater frequency. Why? Part of the answer is clouds and the amount of solar radiation they reflect or absorb. These two factors clouds and radiative transfer represent the greatest source of error and uncertainty in the current generation of general circulation models used for climate research and simulation. The U.S. Global Change Research Act of 1990 established an interagency program within the Executive Office of the President to coordinate U.S. agency-sponsored scientific research designed to monitor, understand, and predict changes in the global environment. To address the need for new research on clouds and radiation, the U.S. Department of Energy (DOE) established the Atmospheric Radiation Measurement (ARM) Program. As part of the DOE?s overall Climate Change Science Program, a primary objective of the ARM Program is improved scientific understanding of the fundamental physics related to interactions between clouds and radiative feedback processes in the atmosphere.

  1. Aeroradiometric Measurements In The Framework Of The ARM03 Exercise; Aeroradiometrische Messungen im Rahmen der Uebung ARM03

    Energy Technology Data Exchange (ETDEWEB)

    Bucher, B.; Rybach, L.; Schwarz, G

    2004-11-01

    The annually repeated measurement flights took place in 2003 from 23 to 26 June and were focused on the bilateral exercise with the Austrian team of the Bundesministerium fuer Inneres (BMI). This exercise was held near Klagenfurt in Kaernten. Furtheron the periodically surveys in the environs of the nuclear power plants Goesgen and Muehleberg were carried out. The flights took place in the framework of the exercise ARM03 and were lead by Y. Loertscher of the Swiss National Emergency Operations Centre (NAZ). As a further activity the results of the international exercise RESUME 2002 in Scotland were compared with measurements on soil sampIes and with in situ gamma spectrometry results. This comparison shows a good agreement within the uncertainties, whereas the {sup 137}Cs results differ the most from the measurements of soil sampIes. This is mainly caused by the different size of the area from which the measured signal is coming for airborne and ground measurements and by the different depth distributions used in the calculations. Within the bilateral exercise in Kaernten six radioactive sources of activities between 120 MBq and 50.4 GBq should be localized by airborne measurements. Two areas with those six sources in each were measured. The Austrian team was using a large volume Geiger-Mueller counter and could localize three sources in each area. Because of the additional spectral information the Swiss team could localize and identify five radioactive sources in each area. The weakest {sup 60}Co source with an activity of 120 MBq could not be detected. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Goesgen and Muehleberg were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Goesgen couldn't be recognised on the activity maps. But the nuclear power plant Muehleberg could be identified by its

  2. Evaluation of cloud fraction and its radiative effect simulated by IPCC AR4 global models against ARM surface observations

    Directory of Open Access Journals (Sweden)

    Y. Qian

    2012-02-01

    Full Text Available Cloud Fraction (CF is the dominant modulator of radiative fluxes. In this study, we evaluate CF simulated in the IPCC AR4 GCMs against ARM long-term ground-based measurements, with a focus on the vertical structure, total amount of cloud and its effect on cloud shortwave transmissivity. Comparisons are performed for three climate regimes as represented by the Department of Energy Atmospheric Radiation Measurement (ARM sites: Southern Great Plains (SGP, Manus, Papua New Guinea and North Slope of Alaska (NSA. Our intercomparisons of three independent measurements of CF or sky-cover reveal that the relative differences are usually less than 10% (5% for multi-year monthly (annual mean values, while daily differences are quite significant. The total sky imager (TSI produces smaller total cloud fraction (TCF compared to a radar/lidar dataset for highly cloudy days (CF > 0.8, but produces a larger TCF value than the radar/lidar for less cloudy conditions (CF < 0.3. The compensating errors in lower and higher CF days result in small biases of TCF between the vertically pointing radar/lidar dataset and the hemispheric TSI measurements as multi-year data is averaged. The unique radar/lidar CF measurements enable us to evaluate seasonal variation of cloud vertical structures in the GCMs.

    Both inter-model deviation and model bias against observation are investigated in this study. Another unique aspect of this study is that we use simultaneous measurements of CF and surface radiative fluxes to diagnose potential discrepancies among the GCMs in representing other cloud optical properties than TCF. The results show that the model-observation and inter-model deviations have similar magnitudes for the TCF and the normalized cloud effect, and these deviations are larger than those in surface downward solar radiation and cloud transmissivity. This implies that other dimensions of cloud in addition to cloud amount, such as cloud optical thickness and

  3. Macrobend optical sensing for pose measurement in soft robot arms

    International Nuclear Information System (INIS)

    Sareh, Sina; Noh, Yohan; Liu, Hongbin; Althoefer, Kaspar; Li, Min; Ranzani, Tommaso

    2015-01-01

    This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic

  4. Uncertainties of Large-Scale Forcing Caused by Surface Turbulence Flux Measurements and the Impacts on Cloud Simulations at the ARM SGP Site

    Science.gov (United States)

    Tang, S.; Xie, S.; Tang, Q.; Zhang, Y.

    2017-12-01

    Two types of instruments, the eddy correlation flux measurement system (ECOR) and the energy balance Bowen ratio system (EBBR), are used at the Atmospheric Radiation Measurement (ARM) program Southern Great Plains (SGP) site to measure surface latent and sensible fluxes. ECOR and EBBR typically sample different land surface types, and the domain-mean surface fluxes derived from ECOR and EBBR are not always consistent. The uncertainties of the surface fluxes will have impacts on the derived large-scale forcing data and further affect the simulations of single-column models (SCM), cloud-resolving models (CRM) and large-eddy simulation models (LES), especially for the shallow-cumulus clouds which are mainly driven by surface forcing. This study aims to quantify the uncertainties of the large-scale forcing caused by surface turbulence flux measurements and investigate the impacts on cloud simulations using long-term observations from the ARM SGP site.

  5. Radiation measurement

    International Nuclear Information System (INIS)

    Go, Sung Jin; Kim, Seung Guk; No, Gyeong Seok; Park, Myeong Hwan; Ann, Bong Seon

    1998-03-01

    This book explains technical terms about radiation measurement, which are radiation, radiation quantity and unit such as prefix of international unit, unit for defence purposes of radiation, coefficient of radiation and interaction, kinds and principles of radiation detector, ionization chamber, G-M counter, G-M tube, proportional counter, scintillation detector, semiconductor radiation detector, thermoluminescence dosimeter, PLD, others detector, radiation monitor, neutron detector, calibration of radiation detector, statistics of counting value, activation analysis and electronics circuit of radiation detector.

  6. Recent Observational Efforts Using the DOE ARM Observatory at Oliktok Point, Alaska

    Science.gov (United States)

    de Boer, G.; Shupe, M.; McComiskey, A. C.; Creamean, J.; Williams, C. R.; Matrosov, S. Y.; Solomon, A.; Turner, D. D.; Norgren, M.; Maahn, M.; Lawrence, D.; Argrow, B. M.; Palo, S. E.; Weibel, D.; Curry, N.; Nichols, T.; D'Amore, P.; Finamore, W.; Ivey, M.; Bendure, A.; Schmid, B.; Biraud, S.

    2016-12-01

    The US Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program has deployed it's third mobile facility (AMF-3) to Oliktok Point, Alaska for an extended measurement campaign. This facility includes a variety of instruments to measure clouds, aerosols, surface meteorology, and surface energy exchange (including radiation). Additionally, this site features two areas of controlled airspace in which additional measurements can be made using manned- and unmanned aircraft and tethered balloons. Over the past two years, several field campaigns have taken place to make measurements complimentary to those collected by the AMF-3. These include several unmanned aircraft and tethered balloon campaigns (Coordinated Observations of the Lower Arctic Atmosphere, COALA; Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems, ERASMUS; Inaugural Campaigns for ARM Research using Unmanned Systems, ICARUS), as well as a manned aircraft campaign during the summer of 2015 (ARM Carbon Measurement Experiment, ACME-5). In addition to these field campaigns, DOE has formed a site science team to conduct research using AMF-3 measurements. In this presentation, we will provide an overview of these measurement campaigns. Additionally, we will provide an overview of scientific results from these campaigns and from AMF-3 research that aid to inform numerical modeling efforts.

  7. Designing and evaluating conventional arms control measures: The case of the Korean peninsula

    International Nuclear Information System (INIS)

    Han Yongsup.

    1991-01-01

    As a method of designing and evaluating arms control measures, this study takes a combined approach of qualitative analysis and military simulation. Three qualitative criteria derived from the case studies on the Korean and European arms control are used to examine whether these measures are legally binding, verifiable, and negotiable. One quantifiable criterion is used to test against the base case scenario (a one-day surprise attach by North Korea) whether arms control measures will stabilize or destabilize the military status quo on the Peninsula in terms of North Korea's extent of penetration in the actual war situations. Four alternative measures are derived from the analysis: (1) Confidence and Security Building Measures (CSBMs); (2) Establishment of Asymmetric Non-Deployment Zone (NDZ); (3) Reduction of the joint US-South Korean 'Team Spirit' exercises and North Korea's Forward Deployed Forces; and, (4) Reduction of South Korean and US forces and North Korean Forces. Findings indicate that establishment of the NDZ and a North Korean unilateral reduction are estimated to best achieve the goal of South Korean arms control

  8. Ultrasound power measurements of HITU transducer with a more stable radiation force balance

    International Nuclear Information System (INIS)

    Karaboece, B; Sadiko'lu, E; Bilgic, E

    2011-01-01

    A new radiation force balance (RFB) system was established at Turkish National Metrology Institute (UME) Ultrasonics Laboratory for High intensity therapeutic ultrasound (HITU) power measurements. The new system is highly stable at high power levels up to 500 Watts. The measurement system consists of a Plexiglas cylindrical balance arm, target mounting scale disks, conical reflecting and absorbing targets, adjustment nuts, and a hanging wire. Both of the two sides of balance were mounted similar size and weight targets. The equilibrium of the balance arm can be adjusted with nuts on screws located at both sides of the balance arm. Transducer was mounted to bottom of water tank. Absorbers in the bottom and the near walls of the tank were used for reflecting target case. Ultrasound power was applied to one scale of the balance where the reflecting/absorbing target was mounted and corresponding force was measured on the other scale of balance where was connected to a balance with a thin wire while the thin rest standing on a support. Ultrasound power of two HITU transducers at frequencies 0.93 MHz, 1.1 MHz and 3.3 MHz were measured with conventional and new system, the values were compared and uncertainty components were assessed in this paper.

  9. Ultrasound power measurements of HITU transducer with a more stable radiation force balance

    Energy Technology Data Exchange (ETDEWEB)

    Karaboece, B; Sadiko' lu, E; Bilgic, E, E-mail: baki.karaboce@ume.tubitak.gov.t [Tuebitak Ulusal Metroloji Enstituesue (UME), P.K. 54 41470 Gebze-Kocaeli (Turkey)

    2011-02-01

    A new radiation force balance (RFB) system was established at Turkish National Metrology Institute (UME) Ultrasonics Laboratory for High intensity therapeutic ultrasound (HITU) power measurements. The new system is highly stable at high power levels up to 500 Watts. The measurement system consists of a Plexiglas cylindrical balance arm, target mounting scale disks, conical reflecting and absorbing targets, adjustment nuts, and a hanging wire. Both of the two sides of balance were mounted similar size and weight targets. The equilibrium of the balance arm can be adjusted with nuts on screws located at both sides of the balance arm. Transducer was mounted to bottom of water tank. Absorbers in the bottom and the near walls of the tank were used for reflecting target case. Ultrasound power was applied to one scale of the balance where the reflecting/absorbing target was mounted and corresponding force was measured on the other scale of balance where was connected to a balance with a thin wire while the thin rest standing on a support. Ultrasound power of two HITU transducers at frequencies 0.93 MHz, 1.1 MHz and 3.3 MHz were measured with conventional and new system, the values were compared and uncertainty components were assessed in this paper.

  10. Radiation dose reduction and new image modalities development for interventional C-arm imaging system

    Science.gov (United States)

    Niu, Kai

    Cardiovascular disease and stroke are the leading health problems and causes of death in the US. Due to the minimally invasive nature of the evolution of image guided techniques, interventional radiological procedures are becoming more common and are preferred in treating many cardiovascular diseases and strokes. In addition, with the recent advances in hardware and device technology, the speed and efficacy of interventional treatment has significantly improved. This implies that more image modalities can be developed based on the current C-arm system and patients treated in interventional suites can potentially experience better health outcomes. However, during the treatment patients are irradiated with substantial amounts of ionizing radiation with a high dose rate (digital subtraction angiography (DSA) with 3muGy/frame and 3D cone beam CT image with 0.36muGy/frame for a Siemens Artis Zee biplane system) and/or a long irradiation time (a roadmapping image sequence can be as long as one hour during aneurysm embolization). As a result, the patient entrance dose is extremely high. Despite the fact that the radiation dose is already substantial, image quality is not always satisfactory. By default a temporal average is used in roadmapping images to overcome poor image quality, but this technique can result in motion blurred images. Therefore, reducing radiation dose while maintaining or even improving the image quality is an important area for continued research. This thesis is focused on improving the clinical applications of C-arm cone beam CT systems in two ways: (1) Improve the performance of current image modalities on the C-arm system. (2) Develop new image modalities based on the current system. To be more specific, the objectives are to reduce radiation dose for current modalities (e.g., DSA, fluoroscopy, roadmapping, and cone beam CT) and enable cone beam CT perfusion and time resolved cone beam CT angiography that can be used to diagnose and triage acute

  11. Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhijin [Univ. of California, Los Angeles, CA (United States); Sha, Feng [Univ. of California, Los Angeles, CA (United States); Liu, Yangang [Brookhaven National Lab. (BNL), Upton, NY (United States); Lin, Wuyin [Brookhaven National Lab. (BNL), Upton, NY (United States); Toto, Tami [Brookhaven National Lab. (BNL), Upton, NY (United States); Vogelmann, Andrew [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-02-02

    This five-year award supports the project “Continuous Evaluation of Fast Processes in Climate Models Using ARM Measurements (FASTER)”. The goal of this project is to produce accurate, consistent and comprehensive data sets for initializing both single column models (SCMs) and cloud resolving models (CRMs) using data assimilation. A multi-scale three-dimensional variational data assimilation scheme (MS-3DVAR) has been implemented. This MS-3DVAR system is built on top of WRF/GSI. The Community Gridpoint Statistical Interpolation (GSI) system is an operational data assimilation system at the National Centers for Environmental Prediction (NCEP) and has been implemented in the Weather Research and Forecast (WRF) model. This MS-3DVAR is further enhanced by the incorporation of a land surface 3DVAR scheme and a comprehensive aerosol 3DVAR scheme. The data assimilation implementation focuses in the ARM SGP region. ARM measurements are assimilated along with other available satellite and radar data. Reanalyses are then generated for a few selected period of time. This comprehensive data assimilation system has also been employed for other ARM-related applications.

  12. Clinical comparison of automatic, noninvasive measurements of blood pressure in the forearm and upper arm.

    Science.gov (United States)

    Schell, Kathleen; Bradley, Elisabeth; Bucher, Linda; Seckel, Maureen; Lyons, Denise; Wakai, Sandra; Bartell, Deborah; Carson, Elizabeth; Chichester, Melanie; Foraker, Teresa; Simpson, Kathleen

    2005-05-01

    When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure. To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm. A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level. Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure). Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.

  13. Real-time statistical quality control and ARM

    International Nuclear Information System (INIS)

    Blough, D.K.

    1992-05-01

    An important component of the Atmospheric Radiation Measurement (ARM) Program is real-time quality control of data obtained from meteorological instruments. It is the goal of the ARM program to enhance the predictive capabilities of global circulation models by incorporating in them more detailed information on the radiative characteristics of the earth's atmosphere. To this end, a number of Cloud and Radiation Testbeds (CART's) will be built at various locations worldwide. Each CART will consist of an array of instruments designed to collect radiative data. The large amount of data obtained from these instruments necessitates real-time processing in order to flag outliers and possible instrument malfunction. The Bayesian dynamic linear model (DLM) proves to be an effective way of monitoring the time series data which each instrument generates. It provides a flexible yet powerful approach to detecting in real-time sudden shifts in a non-stationary multivariate time series. An application of these techniques to data arising from a remote sensing instrument to be used in the CART is provided. Using real data from a wind profiler, the ability of the DLM to detect outliers is studied. 5 refs

  14. Atmospheric Radiation Measurement Climate Research Facility (ACRF) Annual Report 2007

    Energy Technology Data Exchange (ETDEWEB)

    LR Roeder

    2007-12-01

    This annual report describes the purpose and structure of the program, and presents key accomplishments in 2007. Notable achievements include: • Successful review of the ACRF as a user facility by the DOE Biological and Environmental Research Advisory Committee. The subcommittee reinforced the importance of the scientific impacts of this facility, and its value for the international research community. • Leadership of the Cloud Land Surface Interaction Campaign. This multi-agency, interdisciplinary field campaign involved enhanced surface instrumentation at the ACRF Southern Great Plains site and, in concert with the Cumulus Humilis Aerosol Processing Study sponsored by the DOE Atmospheric Science Program, coordination of nine aircraft through the ARM Aerial Vehicles Program. • Successful deployment of the ARM Mobile Facility in Germany, including hosting nearly a dozen guest instruments and drawing almost 5000 visitors to the site. • Key advancements in the representation of radiative transfer in weather forecast models from the European Centre for Medium-Range Weather Forecasts. • Development of several new enhanced data sets, ranging from best estimate surface radiation measurements from multiple sensors at all ACRF sites to the extension of time-height cloud occurrence profiles to Niamey, Niger, Africa. • Publication of three research papers in a single issue (February 2007) of the Bulletin of the American Meteorological Society.

  15. Observational study comparing non-invasive blood pressure measurement at the arm and ankle during caesarean section.

    Science.gov (United States)

    Drake, M J P; Hill, J S

    2013-05-01

    Upper-arm non-invasive blood pressure measurement during caesarean section can be uncomfortable and unreliable because of movement artefact in the conscious parturient. We aimed to determine whether ankle blood pressure measurement could be used instead in this patient group by comparing concurrent arm and ankle blood pressure measured throughout elective caesarean section under regional anaesthesia in 64 term parturients. Bland-Altman analysis of mean difference (95% limits of agreement [range]) between the ankle and arm was 11.2 (-20.3 to +42.7 [-67 to +102]) mmHg for systolic arterial pressure, -0.5 (-21.0 to +19.9 [-44 to +91]) mmHg for mean arterial pressure and -3.8 (-25.3 to +17.8 [-41 to +94]) mmHg for diastolic arterial pressure. Although ankle blood pressure measurement is well tolerated and allows greater mobility of the arms than measurement from the arm, the degree of discrepancy between the two sites is unacceptable to allow routine use of ankle blood pressure measurement, especially for systolic arterial pressure. However, ankle blood pressure measurement may be a useful alternative in situations where arm blood pressure measurement is difficult or impossible. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  16. Blood pressure measurement method and inter-arm differences: a meta-analysis.

    Science.gov (United States)

    Verberk, Willem J; Kessels, Alfons G H; Thien, Theo

    2011-11-01

    Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P arms, with one or two automatic devices and multiple readings should be taken.

  17. ARM Enhanced Shortwave Experiment (ARESE) Solar Radiation Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The ARM Enhanced Shortwave Experiment (ARESE) was conducted at the Department of Energy's ARM Southern Great Plains (SGP) Central Facility between September 22, 1995...

  18. Simultaneous blood pressure measurement in both arms in hypertensive and nonhypertensive adult patients.

    Science.gov (United States)

    Fonseca-Reyes, Salvador; Forsyth-MacQuarrie, Avril M; García de Alba-García, Javier Eduardo

    2012-08-01

    When blood pressure (BP) is taken for the first time, it should be measured in both arms; follow-up measurements should be taken in the arm with the highest BP. However, in clinical practice, this recommendation is rarely followed. Identify the degree of differences in BP between the right and the left arm in individuals with normal and high BP. We measured BP in 111 hypertensive and 80 normotensive patients in both arms at the same time using identical Omron HEM 725 CIC automatic sphygmomanometers. The devices were then switched to the other arm and another set of readings was taken. The absolute and relative difference in BP between arms was calculated from the average of these two readings. We categorized differences as at least 5, at least 10, and at least 20 mmHg for systolic blood pressure/diastolic blood pressure (SBP/DBP). The BP was higher in the right arm, with no statistical significance. The relative differences were also not significant: SBP 1.1±7.1 and DBP 0.21±5.0. However, the absolute differences were significant at an individual level, with a systolic difference of 5.4±4.8 mmHg and a diastolic difference of 3.9 ±3.2 mmHg. The percentages of absolute SBP/DBP differences more than 5 mmHg (21.4%/20.4%) and more than 10 mmHg (15.7%/4.7%) were considerable. The range of arm differences was clinically significant; in hypertensives, the SBP/DBP was -13.2 to +15/-9.2 to +9.6 mmHg and in nonhypertensives it was -12.9 to +15.6/-9.7 to +10.1 mmHg. Although on average there was no clinically significant relative difference between arms, absolute differences at an individual level were often clinically significant. Failure to determine interarm BP differences will lead to erroneous clinical decisions.

  19. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  20. Placement of iliosacral screws using 3D image-guided (O-Arm) technology and Stealth Navigation: comparison with traditional fluoroscopy.

    Science.gov (United States)

    Theologis, A A; Burch, S; Pekmezci, M

    2016-05-01

    We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (sd) 1922) than during fluoroscopy (11.9 mRem sd 14.8) (p Cite this article: Bone Joint J 2016;98-B:696-702. ©2016 The British Editorial Society of Bone & Joint Surgery.

  1. Observations of a cold front with strong vertical undulations during the ARM RCS-IOP

    Energy Technology Data Exchange (ETDEWEB)

    Starr, D.O`C.; Whiteman, D.N. [Goddard Space Flight Center, Greenbelt, MD (United States); Melfi, S.H. [Univ. of Maryland, Baltimore, MD (United States)] [and others

    1996-04-01

    Passage of a cold front was observed on the night of April 14-15, 1994, during the Atmospheric Radiation Measurement (ARM) Remote Cloud Sensing (RCS) Intensive Observatios Period (IOP) at the Southern Great Plains Cloud and Radiation Testbed (CART) site near Lamont, Oklahoma. The observations are described.

  2. Airborne gamma spectrometry measurements in the context of the exercise ARM02; Aeroradiometrische Messungen im Rahmen der Uebung ARM02

    Energy Technology Data Exchange (ETDEWEB)

    Bucher, B.; Rybach, L. [ETH Zuerich (Switzerland); Schwarz, G. [Swiss Nuclear Safety Authority, Villigen (Switzerland); Baerlocher, C. [ETH Zuerich (Switzerland)

    2003-05-01

    The international exercise under the European Union project ECCOMAGS (European Coordination and Calibration of Mobile and Airborne Gamma Spectrometry) stood in the centre of the yearly airborne gamma spectrometry measurement flights which were carried out in the time of 27 -31 May 2002. The exercise was held in Southwest Scotland in the region of Dumfries and Galloway. Unfortunately due to difficulties with flight approvals for military aircrafts data could be taken in the exercise area only on the flight back to Switzerland. Immediately after returning to Switzerland the regular measurements around the nuclear power plants Beznau (KKB) and Leibstadt (KKL), around the intermediate storage facilities for radioactive waste (ZWILAG) and around the research facility Paul Scherrer Institute were performed. The flights took place in the context of the exercise ARM02 and were lead by the Swiss National Emergency Operations Centre (NAZ). Unfortunately just a few measurements in the common intercalibration areas could be taken on the flight back from the international exercise. Nevertheless comparisons of the results with those of other European teams could be made. These comparisons proved the good calibration of our equipment. On the flight back measurements were also carried out at great altitude above the sea. This data allowed to determine very well the background of the aircraft and the cosmic stripping ratios. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Beznau and Leibstadt and around the nuclear research facility Paul Scherrer Institute were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Beznau couldn't be recognised on the activity maps. But the nuclear power plant Leibstadt could be identified by its direct radiation which is specific for this type of reactor (BWR). At the site of the Paul

  3. Counterbalanced radiation detection system

    International Nuclear Information System (INIS)

    Platz, W.

    1987-01-01

    A counterbalanced radiation detection system is described comprising: (a) a stand; (b) a first radiation detector; (c) a first radiation detector arm means for tiltably connecting the first radiation detector with the stand; (d) a second radiation detector; (e) a second radiation detector arm means for tiltably connecting the second radiation detector with the stand, whereby the tilting angles of the radiation detector arm means define a distance between the radiation detectors; and (f) a torque transforming means connected between the first and second radiation detector arm means for transforming the torque created by one of the radiation detectors in a sense opposed to the torque created by the other radiation detector

  4. Testbed model and data assimilation for ARM

    International Nuclear Information System (INIS)

    Louis, J.F.

    1992-01-01

    The objectives of this contract are to further develop and test the ALFA (AER Local Forecast and Assimilation) model originally designed at AER for local weather prediction and apply it to three distinct but related purposes in connection with the Atmospheric Radiation Measurement (ARM) program: (a) to provide a testbed that simulates a global climate model in order to facilitate the development and testing of new cloud parametrizations and radiation models; (b) to assimilate the ARM data continuously at the scale of a climate model, using the adjoint method, thus providing the initial conditions and verification data for testing parameumtions; (c) to study the sensitivity of a radiation scheme to cloud parameters, again using the adjoint method, thus demonstrating the usefulness of the testbed model. The data assimilation will use a variational technique that minimizes the difference between the model results and the observation during the analysis period. The adjoint model is used to compute the gradient of a measure of the model errors with respect to nudging terms that are added to the equations to force the model output closer to the data. The radiation scheme that will be included in the basic ALFA model makes use of a gen two-stream approximation, and is designed for vertically inhonogeneous, multiple-scattering atmospheres. The sensitivity of this model to the definition of cloud parameters will be studied. The adjoint technique will also be used to compute the sensitivities. This project is designed to provide the Science Team members with the appropriate tools and modeling environment for proper testing and tuning of new radiation models and cloud parametrization schemes

  5. ARM User Survey Report: Data Access, Quality, and Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Mather, JH; Roeder, LR; Sivaraman, C

    2012-06-28

    The objective of this survey was to obtain user feedback to determine how users of the Atmospheric Radiation Measurement (ARM) Climate Research Facility Data Archive interact with the more than 2000 available types of datastreams. The survey also gathered information about data discovery and data quality. The Market and Competitive Analysis group at Pacific Northwest National Laboratory worked with web administrators to develop a landing page from which users could access the survey. A survey invitation was sent by ARM via email to about 6100 users on February 22, 2012. The invitation was also posted on the ARM website and Facebook page. Reminders were sent via e-mail and posted on Facebook while the survey was open, February 22-March 23, 2012.

  6. Satellite Data Support for the ARM Climate Research Facility, 8/01/2009 - 7/31/2015

    Energy Technology Data Exchange (ETDEWEB)

    Minnis, Patrick [NASA Langley Research Center, Hampton, VA (United States); Khaiyer, Mandana M [Science Systems and Applications, Inc., Hampton, VA (United States)

    2015-10-06

    This report summarizes the support provided by NASA Langley Research for the DOE ARM Program in the form of cloud and radiation products derived from satellite imager data for the period between 8/01/09 through 7/31/15. Cloud properties such as cloud amount, height, and optical depth as well as outgoing longwave and shortwave broadband radiative fluxes were derived from geostationary and low-earth orbiting satellite imager radiance measurements for domains encompassing ARM permanent sites and field campaigns during the performance period. Datasets provided and documents produced are listed.

  7. Arm-associated measurements as estimates of true height in black ...

    African Journals Online (AJOL)

    arm-associated measurements to true height included that of the World Health ... Conclusion: Findings indicate the need for gender and race-specific height estimation ..... New. York, NY: Springer; 2012. 12. Golshan M, Amra B, Hoghoghi MA.

  8. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  9. Some possible applications of measurements on mu mesons to nuclear safeguards, nonproliferation, and arms control activities

    International Nuclear Information System (INIS)

    Kane, W.R.; Vanier, P.E.

    1997-01-01

    In the nuclear safeguards and arms control areas, well-developed methodologies exist for determining the properties of nuclear materials via measurements of the gamma rays and neutrons emitted from these materials, or in the arms control area, by the use of radiography. In certain favorable instances, it may by feasible to perform comparable measurements with the use of a ubiquitous, naturally-occurring radiation--cosmic ray mu mesons (muons). At the earth's surface these charged particles have a broad energy distribution peaking at about 500 MeV with a flux of approximately 10 -2 /cm 2 -sec-steradian. In traversing matter, muons lose energy at a rate of approximately 2 MeV/gram almost independent of atomic number. Muons can readily be detected by either plastic scintillators or wire planes. While the flux is small, a scintillator of one meter area, for example, will register about 20,000 events/min. these particles should have utility in the detection and imaging of objects with sectional densities of a few hundred grams/cm 2 . The degree of intrusiveness of the imaging can be controlled through the detector configuration. Some possible applications include: (1) mass measurements on large UF 6 cylinders, (2) determination of the size of treaty-limited objects, e.g., missiles, in rail cars or other containment; (3) verification of single or multiple warheads or components; (4) the detection of concealed, underground cavities. Examples will be presented

  10. Treatment of cloud radiative effects in general circulation models

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W.C.; Dudek, M.P.; Liang, X.Z.; Ding, M. [State Univ. of New York, Albany, NY (United States)] [and others

    1996-04-01

    We participate in the Atmospheric Radiation Measurement (ARM) program with two objectives: (1) to improve the general circulation model (GCM) cloud/radiation treatment with a focus on cloud verticle overlapping and layer cloud optical properties, and (2) to study the effects of cloud/radiation-climate interaction on GCM climate simulations. This report summarizes the project progress since the Fourth ARM Science Team meeting February 28-March 4, 1994, in Charleston, South Carolina.

  11. Airborne gamma spectrometry measurements in the context of the exercise ARM02

    International Nuclear Information System (INIS)

    Bucher, B.; Rybach, L.; Schwarz, G.; Baerlocher, C.

    2003-05-01

    The international exercise under the European Union project ECCOMAGS (European Coordination and Calibration of Mobile and Airborne Gamma Spectrometry) stood in the centre of the yearly airborne gamma spectrometry measurement flights which were carried out in the time of 27 -31 May 2002. The exercise was held in Southwest Scotland in the region of Dumfries and Galloway. Unfortunately due to difficulties with flight approvals for military aircrafts data could be taken in the exercise area only on the flight back to Switzerland. Immediately after returning to Switzerland the regular measurements around the nuclear power plants Beznau (KKB) and Leibstadt (KKL), around the intermediate storage facilities for radioactive waste (ZWILAG) and around the research facility Paul Scherrer Institute were performed. The flights took place in the context of the exercise ARM02 and were lead by the Swiss National Emergency Operations Centre (NAZ). Unfortunately just a few measurements in the common intercalibration areas could be taken on the flight back from the international exercise. Nevertheless comparisons of the results with those of other European teams could be made. These comparisons proved the good calibration of our equipment. On the flight back measurements were also carried out at great altitude above the sea. This data allowed to determine very well the background of the aircraft and the cosmic stripping ratios. In the context of the regular measurements in the environs of the nuclear facilities in Switzerland the areas around the nuclear power plants Beznau and Leibstadt and around the nuclear research facility Paul Scherrer Institute were measured. The results were very similar to the results of earlier measurements in the last years. The nuclear power plant Beznau couldn't be recognised on the activity maps. But the nuclear power plant Leibstadt could be identified by its direct radiation which is specific for this type of reactor (BWR). At the site of the Paul

  12. Design And Measurement Of Radiation Exposure Rates At An X-Ray Diagnostic Radiological Unit

    International Nuclear Information System (INIS)

    Tito-Sutjipto

    2003-01-01

    Every radiation employees suffers radiation exposure risk while doing his job. It is important therefore to investigate the occupational health and safety of radiation employees on its relationship with the design and measurement of radiation exposure rates at an X-ray diagnostic radiological unit in this work, a case study was held on the radiological unit at BP-4 Yogyakarta for patient diagnostics, This research armed to investigate the relationship between the design of radiological unit for X-ray diagnostics and the location of the X-ray machine, based on the distance variable and radiation exposure rate during patient diagnostics. This was performed using radiological unit design data for X-ray diagnostics and the measurement of radiation exposure rates throughout patient diagnostics. The design data can then be used for determining the requirement of primary and secondary shielding materials for radiological unit as well as a calculation basis of radiation exposure rates during patient diagnostics. From the result of the research, it can be concluded that from the occupational health and safety point of view, radiation exposure around the X-ray machines are fairly good, both for the shielding materials in each X-ray room and the radiation exposures received by the workers, because they are far beyond the maximum permittable average limit (16.67 m R/days). (author)

  13. [Treatment of cloud radiative effects in general circulation models

    International Nuclear Information System (INIS)

    Wang, W.C.

    1993-01-01

    This is a renewal proposal for an on-going project of the Department of Energy (DOE)/Atmospheric Radiation Measurement (ARM) Program. The objective of the ARM Program is to improve the treatment of radiation-cloud in GCMs so that reliable predictions of the timing and magnitude of greenhouse gas-induced global warming and regional responses can be made. The ARM Program supports two research areas: (I) The modeling and analysis of data related to the parameterization of clouds and radiation in general circulation models (GCMs); and (II) the development of advanced instrumentation for both mapping the three-dimensional structure of the atmosphere and high accuracy/precision radiometric observations. The present project conducts research in area (I) and focuses on GCM treatment of cloud life cycle, optical properties, and vertical overlapping. The project has two tasks: (1) Development and Refinement of GCM Radiation-Cloud Treatment Using ARM Data; and (2) Validation of GCM Radiation-Cloud Treatment

  14. LES ARM Symbiotic Simulation and Observation (LASSO) Implementation Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Gustafson Jr., WI [Pacific Northwest National Laboratory; Vogelmann, AM [Brookhaven National Laboratory

    2015-09-01

    This document illustrates the design of the Large-Eddy Simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) workflow to provide a routine, high-resolution modeling capability to augment the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s high-density observations. LASSO will create a powerful new capability for furthering ARM’s mission to advance understanding of cloud, radiation, aerosol, and land-surface processes. The combined observational and modeling elements will enable a new level of scientific inquiry by connecting processes and context to observations and providing needed statistics for details that cannot be measured. The result will be improved process understanding that facilitates concomitant improvements in climate model parameterizations. The initial LASSO implementation will be for ARM’s Southern Great Plains site in Oklahoma and will focus on shallow convection, which is poorly simulated by climate models due in part to clouds’ typically small spatial scale compared to model grid spacing, and because the convection involves complicated interactions of microphysical and boundary layer processes.

  15. Upper arm circumference measurement for detecting overweight and obesity in children aged 6-7 years

    Directory of Open Access Journals (Sweden)

    Dewi Rosariah Ayu

    2017-02-01

    Full Text Available Background Obesity is a worldwide problem and is associated with increased risk of metabolic syndrome. Nutritional status in children has traditionally been determined by body mass index (BMI scores, but with limitations. Upper arm circumference measurement may be a better predictor of energy, protein, and fat storage, as well as a simpler method for screening overweight and obesity in children. Objective To determine the diagnostic value of upper arm circumference compared to BMI for detecting overweight and obesity in children aged 6-7 years. Methods This diagnostic study with a cross-sectional design was performed from September to October 2015 at 16 primary schools in Palembang, Indonesia. We measured the heights, weights, and upper arm circumferences, and calculated BMIs of 2,258 children. Receiver-operator characteristic (ROC curve analysis was used to find an optimal upper arm circumference cut-off point to detect overweight and obesity. Diagnostic value was calculated by using a 2x2 table analysis. Results The prevalences of overweight and obesity were 5.8% and 11.7%, respectively. The optimal upper arm circumference cut-off points for detecting overweight in children aged 6-7 years was 185 mm (sensitivity 88.1% and specificity 78.3%, and for obesity was 195 mm (sensitivity 90.15% and specificity 86.65%. Upper arm circumference had a strong correlation with BMI. Conclusion Upper arm circumference measurement is an accurate method fordistinguishing between normoweight, overweight, and obesity in children aged 6-7 years.

  16. ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chengzhu [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Xie, Shaocheng [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-10-15

    A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstrated in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which

  17. Atmospheric Radiation Measurement Program facilities newsletter, February 2001.; TOPICAL

    International Nuclear Information System (INIS)

    Holdridge, D. J.

    2001-01-01

    This newsletter consists of the following: (1) ARM Science Team Meeting Scheduled-The 11th Annual ARM Science Team meeting is scheduled for March 19-23, 2001, in Atlanta, Georgia. Members of the science team will exchange research results achieved by using ARM data. The science team is composed of working groups that investigate four topics: instantaneous radiative flux, cloud parameterizations and modeling, cloud properties, and aerosols. The annual meeting brings together the science team's 150 members to discuss issues related to ARM and its research. The members represent universities, government laboratories and research facilities, and independent research companies. (2) Communications to Extended Facilities Upgraded-New communications equipment has been installed at all of the SGP extended facilities. Shelters were installed to house the new equipment used to transfer data from instruments via the Internet to the site data system at the central facility. This upgrade has improved data availability from the extended facilities to 100% and reduced telephone costs greatly. (3) SGP Goes ''Buggy''-Steve Sekelsky, a researcher from the University of Massachusetts, is planning to bring a 95-GHz radar to the SGP central facility for deployment in March-October 2001. The radar will help to identify signals due to insects flying in the air. The ARM millimeter cloud radar, which operates at 35 GHz, is sensitive to such insect interference. Testing will also be performed by using a second 35-GHz radar with a polarized radar beam, which can differentiate signals from insects versus cloud droplets. (4) Winter Fog-Fog can add to hazards already associated with winter weather. Common types of fog formation include advection, radiation, and steam. Advection fog: An advection fog is a dense fog that forms when a warm, moist air mass moves into an area with cooler ground below. For example, fog can form in winter when warmer, water-saturated air from the south (associated with

  18. The Design of EMG Measurement System for Arm Strength Training Machine

    Directory of Open Access Journals (Sweden)

    Tze-Yee Ho

    2015-01-01

    Full Text Available The setup of interactive communication between arm strength training machine and the people will make exercise and rehabilitation therapy become more friendly. The employment of electromyographic not only can help physical therapy but also can achieve more effective rehabilitation. Both of the system hardware and software of the arm strength training machine with EMG system are well designed and described. The fundamental design of electromyographic measurement system based on a microcontroller is analyzed and discussed. The software programming is developed in MPLAB integrated development environment from the Microchip Technology Inc. and the friendly user interface is created as well. Finally, an arm strength training machine with electromyographic control system is realized and demonstrated. The experimental results show the feasibility and fidelity of the complete designed system.

  19. Tools and methods for experimental in-vivo measurement and biomechanical characterization of an Octopus vulgaris arm.

    Science.gov (United States)

    Margheri, Laura; Mazzolai, Barbara; Cianchetti, Matteo; Dario, Paolo; Laschi, Cecilia

    2009-01-01

    This work illustrates new tools and methods for an in vivo and direct, but non-invasive, measurement of an octopus arm mechanical properties. The active elongation (longitudinal stretch) and the pulling force capability are measured on a specimen of Octopus vulgaris in order to quantitatively characterize the parameters describing the arm mechanics, for biomimetic design purposes. The novel approach consists of observing and measuring a living octopus with minimally invasive methods, which allow the animal to move with its complete ability. All tools are conceived in order to create a collaborative interaction with the animal for the acquisition of active measures. The data analysis is executed taking into account the presence of an intrinsic error due to the mobility of the subject and the aquatic environment. Using a system of two synchronized high-speed high-resolution cameras and purpose-made instruments, the maximum elongation of an arm and its rest length (when all muscles fibres are relaxed during propulsion movement) are measured and compared to define the longitudinal stretch, with the impressive average result of 194%. With a similar setup integrated with a force sensor, the pulling force capability is measured as a function of grasp point position along the arm. The measured parameters are used as real specifications for the design of an octopus-like arm with a biomimetic approach.

  20. Verifying Operational and Developmental Air Force Weather Cloud Analysis and Forecast Products Using Lidar Data from Department of Energy Atmospheric Radiation Measurement (ARM) Sites

    Science.gov (United States)

    Hildebrand, E. P.

    2017-12-01

    Air Force Weather has developed various cloud analysis and forecast products designed to support global Department of Defense (DoD) missions. A World-Wide Merged Cloud Analysis (WWMCA) and short term Advected Cloud (ADVCLD) forecast is generated hourly using data from 16 geostationary and polar-orbiting satellites. Additionally, WWMCA and Numerical Weather Prediction (NWP) data are used in a statistical long-term (out to five days) cloud forecast model known as the Diagnostic Cloud Forecast (DCF). The WWMCA and ADVCLD are generated on the same polar stereographic 24 km grid for each hemisphere, whereas the DCF is generated on the same grid as its parent NWP model. When verifying the cloud forecast models, the goal is to understand not only the ability to detect cloud, but also the ability to assign it to the correct vertical layer. ADVCLD and DCF forecasts traditionally have been verified using WWMCA data as truth, but this might over-inflate the performance of those models because WWMCA also is a primary input dataset for those models. Because of this, in recent years, a WWMCA Reanalysis product has been developed, but this too is not a fully independent dataset. This year, work has been done to incorporate data from external, independent sources to verify not only the cloud forecast products, but the WWMCA data itself. One such dataset that has been useful for examining the 3-D performance of the cloud analysis and forecast models is Atmospheric Radiation Measurement (ARM) data from various sites around the globe. This presentation will focus on the use of the Department of Energy (DoE) ARM data to verify Air Force Weather cloud analysis and forecast products. Results will be presented to show relative strengths and weaknesses of the analyses and forecasts.

  1. ARM Tethered Balloon System & AALCO Activities at AMF3 Site at Oliktok Point, AK

    Science.gov (United States)

    Hardesty, J.; Dexheimer, D.; Mei, F.; Roesler, E. L.; Longbottom, C.; Hillman, B. R.

    2017-12-01

    Sandia National Laboratories (SNL) has operated the Atmospheric Radiation Measurement program's (ARM) third ARM Mobile Facility (AMF3) and the restricted airspace associated with it at Oliktok Point, Alaska, since October 2013. The site hosts ground-based instrumentation which collects a variety of continuous atmospheric measurements as well as user-conducted unmanned aircraft and tethered balloon campaigns. SNL has operated ARM's tethered balloon system (TBS) as part of the Inaugural Campaigns for ARM Research using Unmanned Systems (ICARUS) since 2016. AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), is an ARM Intensive Operations Period conducted by SNL at the AMF3 since 2016. The operation of the TBS during ICARUS and AALCO to altitudes above 4,000' AGL in a variety of seasons and conditions is addressed. A Distributed Temperature Sensing (DTS) system and supercooled liquid water content (SLWC) sensors have been deployed under both campaigns. The performance of these sensors is discussed and results are presented. DTS measurements and their relationship to concurrent temperature measurements from unmanned aircraft and radiosondes are shown. SLWC sensor in situ measurements are compared with microwave radiometer and radiosonde-derived measurements. Preliminary analysis of using Large Eddy Simulations to compare with the SLWC measurements reveals three-dimensional properties of the observed clouds.

  2. Department of Energy’s ARM Climate Research Facility External Data Center Operations Plan Located At Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Cialella, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gregory, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lazar, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Liang, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ma, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tilp, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wagener, R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-01

    The External Data Center (XDC) Operations Plan describes the activities performed to manage the XDC, located at Brookhaven National Laboratory (BNL), for the Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility. It includes all ARM infrastructure activities performed by the Data Management and Software Engineering Group (DMSE) at BNL. This plan establishes a baseline of expectation within the ARM Operations Management for the group managing the XDC.

  3. Design and implementation of a computer based site operations log for the ARM Program

    International Nuclear Information System (INIS)

    Tichler, J.L.; Bernstein, H.J.; Bobrowski, S.F.; Melton, R.B.; Campbell, A.P.; Edwards, D.M.; Kanciruk, P.; Singley, P.T.

    1992-01-01

    The Atmospheric Radiation Measurement (ARM) Program is a Department of Energy (DOE) research effort to reduce the uncertainties found in general circulation and other models due to the effects of clouds and solar radiation. ARM will provide an experimental testbed for the study of important atmospheric effects, particularly cloud and radiative processes, and testing of parameterizations of the processes for use in atmospheric models. The design of the testbed known as the Clouds and Radiation Testbed (CART), calls for five, long-term field data collection sites. The first site, located in the Southern Great Plains (SGP) in Lamont, OK began operation in the spring of 1992. The CART Data Environment (CDE) is the element of the testbed which acquires the basic observations from the instruments and processes them to meet the ARM requirements. A formal design was used to develop a description of the logical requirements for the CDE. This paper discusses the design and prototype implementation of a part of the CDE known as the site operations log, which records metadata defining the environment within which the data produced by the instruments is collected

  4. Study of Shortwave Spectra in Fully 3D Environment: Synergy Between Scanning Radars and Spectral Radiation Measurements

    Science.gov (United States)

    Wiscombe, Warren J.

    2012-01-01

    The main theme for our research is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars, shortwave spectrometers, and microwave radiometers with the arsenal of radiative transfer tools developed by our group. In particular, we define first a large number of cloudy test cases spanning all 3D possibilities not just the customary uniform-overcast ones. Second, for each case, we define a "Best Estimate of Clouds That Affect Shortwave Radiation" using all relevant ARM instruments, notably the new scanning radars, and contribute this to the ARM Archive. Third, we test the ASR-signature radiative transfer model RRTMG_SW for those cases, focusing on the near-IR because of long-standing problems in this spectral region, and work with the developers to improve RRTMG_SW in order to increase its penetration into the modeling community.

  5. Acupuncture for radiation or combined treatment induced edema in arms and legs of breast and cervical cancer patients

    International Nuclear Information System (INIS)

    Bardychev, M.S.; Guseva, L.I.; Zubova, N.D.

    1988-01-01

    Acupuncture was carried out in 141 sufferers from delayed radiation injuries to skin and soft tissues. 122 patients (86%) revealed clinical manifestations of edema of varying gravity in arms and legs, while 19 (14%) suffered radiation-induced neufritis or plexitis unaccompanied by edema. Radionuclide and rheographic studies as well as evaluation of hemostatic function showed acupuncture to be an effective treatment for edema and pain. it also improved lymph flow, rheovasographic indexes and normalized hemostasis. The best results were obtained in cases of stage 1-2 edema

  6. Acupuncture for radiation or combined treatment induced edema in arms and legs of breast and cervical cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Bardychev, M S; Guseva, L I; Zubova, N D

    1988-01-01

    Acupuncture was carried out in 141 sufferers from delayed radiation injuries to skin and soft tissues. 122 patients (86%) revealed clinical manifestations of edema of varying gravity in arms and legs, while 19 (14%) suffered radiation-induced neufritis or plexitis unaccompanied by edema. Radionuclide and rheographic studies as well as evaluation of hemostatic function showed acupuncture to be an effective treatment for edema and pain. it also improved lymph flow, rheovasographic indexes and normalized hemostasis. The best results were obtained in cases of stage 1-2 edema.

  7. Remote Sensing and In-Situ Observations of Arctic Mixed-Phase and Cirrus Clouds Acquired During Mixed-Phase Arctic Cloud Experiment: Atmospheric Radiation Measurement Uninhabited Aerospace Vehicle Participation

    International Nuclear Information System (INIS)

    McFarquhar, G.M.; Freer, M.; Um, J.; McCoy, R.; Bolton, W.

    2005-01-01

    The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring

  8. A radiation closure study of Arctic stratus cloud microphysical properties using the collocated satellite-surface data and Fu-Liou radiative transfer model

    Science.gov (United States)

    Dong, Xiquan; Xi, Baike; Qiu, Shaoyue; Minnis, Patrick; Sun-Mack, Sunny; Rose, Fred

    2016-09-01

    Retrievals of cloud microphysical properties based on passive satellite imagery are especially difficult over snow-covered surfaces because of the bright and cold surface. To help quantify their uncertainties, single-layered overcast liquid-phase Arctic stratus cloud microphysical properties retrieved by using the Clouds and the Earth's Radiant Energy System Edition 2 and Edition 4 (CERES Ed2 and Ed4) algorithms are compared with ground-based retrievals at the Atmospheric Radiation Measurement North Slope of Alaska (ARM NSA) site at Barrow, AK, during the period from March 2000 to December 2006. A total of 206 and 140 snow-free cases (Rsfc ≤ 0.3), and 108 and 106 snow cases (Rsfc > 0.3), respectively, were selected from Terra and Aqua satellite passes over the ARM NSA site. The CERES Ed4 and Ed2 optical depth (τ) and liquid water path (LWP) retrievals from both Terra and Aqua are almost identical and have excellent agreement with ARM retrievals under snow-free and snow conditions. In order to reach a radiation closure study for both the surface and top of atmosphere (TOA) radiation budgets, the ARM precision spectral pyranometer-measured surface albedos were adjusted (63.6% and 80% of the ARM surface albedos for snow-free and snow cases, respectively) to account for the water and land components of the domain of 30 km × 30 km. Most of the radiative transfer model calculated SW↓sfc and SW↑TOA fluxes by using ARM and CERES cloud retrievals and the domain mean albedos as input agree with the ARM and CERES flux observations within 10 W m-2 for both snow-free and snow conditions. Sensitivity studies show that the ARM LWP and re retrievals are less dependent on solar zenith angle (SZA), but all retrieved optical depths increase with SZA.

  9. ARM Cloud-Aerosol-Precipitation Experiment (ACAPEX) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Leung, L Ruby [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-01

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s ARM Cloud-Aerosol-Precipitation Experiment (ACAPEX) field campaign contributes to CalWater 2015, a multi-agency field campaign that aims to improve understanding of atmospheric rivers and aerosol sources and transport that influence cloud and precipitation processes. The ultimate goal is to reduce uncertainties in weather predictions and climate projections of droughts and floods in California. With the DOE G-1 aircraft and ARM Mobile Facility 2 (AMF2) well equipped for making aerosol and cloud measurements, ACAPEX focuses specifically on understanding how aerosols from local pollution and long-range transport affect the amount and phase of precipitation associated with atmospheric rivers. ACAPEX took place between January 12, 2015 and March 8, 2015 as part of CalWater 2015, which included four aircraft (DOE G-1, National Oceanic and Atmospheric Administration [NOAA] G-IV and P-3, and National Aeronautics and Space Administration [NASA] ER-2), the NOAA research ship Ron Brown, carrying onboard the AMF2, National Science Foundation (NSF)-sponsored aerosol and precipitation measurements at Bodega Bay, and the California Department of Water Resources extreme precipitation network.

  10. A Climatology of Midlatitude Continental Clouds from the ARM SGP Central Facility. Part II; Cloud Fraction and Radiative Forcing

    Science.gov (United States)

    Dong, Xiquan; Xi, Baike; Minnis, Patrick

    2006-01-01

    Data collected at the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) central facility are analyzed for determining the variability of cloud fraction and radiative forcing at several temporal scales between January 1997 and December 2002. Cloud fractions are estimated for total cloud cover and for single-layer low (0-3 km), middle (3-6 km), and high clouds (greater than 6 km) using ARM SGP ground-based paired lidar-radar measurements. Shortwave (SW), longwave (LW), and net cloud radiative forcings (CRF) are derived from up- and down-looking standard precision spectral pyranometers and precision infrared radiometer measurements. The annual averages of total, and single-layer, nonoverlapped low, middle and high cloud fractions are 0.49, 0.11, 0.03, and 0.17, respectively. Total and low cloud amounts were greatest from December through March and least during July and August. The monthly variation of high cloud amount is relatively small with a broad maximum from May to August. During winter, total cloud cover varies diurnally with a small amplitude, mid-morning maximum and early evening minimum, and during summer it changes by more than 0.14 over the daily cycle with a pronounced early evening minimum. The diurnal variations of mean single-layer cloud cover change with season and cloud height. Annual averages of all-sky, total, and single-layer high, middle, and low LW CRFs are 21.4, 40.2, 16.7, 27.2, and 55.0 Wm(sup -2), respectively; and their SW CRFs are -41.5, -77.2, -37.0, -47.0, and -90.5 Wm(sup -2). Their net CRFs range from -20 to -37 Wm(sup -2). For all-sky, total, and low clouds, the maximum negative net CRFs of -40.1, -70, and -69.5 Wm(sup -2), occur during April; while the respective minimum values of -3.9, -5.7, and -4.6 Wm(sup -2), are found during December. July is the month having maximum negative net CRF of -46.2 Wm(sup -2) for middle clouds, and May has the maximum value of -45.9 Wm(sup -2) for high clouds. An

  11. Comparison of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease with Flat-Panel Detectors on Mobile C-arm versus Fixed Systems.

    Science.gov (United States)

    Guillou, Marie; Maurel, Blandine; Necib, Hatem; Vent, Pierre-Alexandre; Costargent, Alain; Chaillou, Philippe; Gouëffic, Yann; Kaladji, Adrien

    2018-02-01

    Flat-panel detectors on mobile C-arm (MC-arm) systems are currently challenging fixed C-arm (FC-arm) systems used in hybrid operating rooms. MC-arm systems offer an alternative to FC-arm systems in the endovascular treatment of peripheral arterial disease (PAD) but their efficiency has not been evaluated comparatively. Two series of patients undergoing arteriography with intention to treat were included. Each series consisted of 2 nonrandomized groups: an MC-arm group and an FC-arm group. Series 1 evaluated exposure to the patient (MC-arm, n = 113; FC-arm, n = 206) while series 2 evaluated exposure to patients and also health care personnel (MC-arm, n = 24; FC-arm, n = 76). The primary end points for evaluating exposure were air kerma (AK, in mGy) for patients and effective dose for health care personnel (in μSv). After adjustment for the effect of body mass index (analysis of covariance test), AK was found to be lower in the MC-arm group than in the FC-arm group (124.1 ± 142 vs. 173.3 ± 248.7, P = 0.025). There was no difference between the groups with regard to effective dose recorded for senior surgeons or for operating room nurses. However, a higher effective dose was recorded by the MC-arm group external dosimeter for the trainee resident and for nurse anesthetists. In endovascular treatment of lower limb PAD, use of an FC-arm system is associated with more radiation exposure to the patient than an MC-arm system. However, this type of imaging system does not appear to affect exposure to health care personnel. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Exploring Large Scale Data Analysis and Visualization for ARM Data Discovery Using NoSQL Technologies

    Science.gov (United States)

    Krishna, B.; Gustafson, W. I., Jr.; Vogelmann, A. M.; Toto, T.; Devarakonda, R.; Palanisamy, G.

    2016-12-01

    This paper presents a new way of providing ARM data discovery through data analysis and visualization services. ARM stands for Atmospheric Radiation Measurement. This Program was created to study cloud formation processes and their influence on radiative transfer and also include additional measurements of aerosol and precipitation at various highly instrumented ground and mobile stations. The total volume of ARM data is roughly 900TB. The current search for ARM data is performed by using its metadata, such as the site name, instrument name, date, etc. NoSQL technologies were explored to improve the capabilities of data searching, not only by their metadata, but also by using the measurement values. Two technologies that are currently being implemented for testing are Apache Cassandra (noSQL database) and Apache Spark (noSQL based analytics framework). Both of these technologies were developed to work in a distributed environment and hence can handle large data for storing and analytics. D3.js is a JavaScript library that can generate interactive data visualizations in web browsers by making use of commonly used SVG, HTML5, and CSS standards. To test the performance of NoSQL for ARM data, we will be using ARM's popular measurements to locate the data based on its value. Recently noSQL technology has been applied to a pilot project called LASSO, which stands for LES ARM Symbiotic Simulation and Observation Workflow. LASSO will be packaging LES output and observations in "data bundles" and analyses will require the ability for users to analyze both observations and LES model output either individually or together across multiple time periods. The LASSO implementation strategy suggests that enormous data storage is required to store the above mentioned quantities. Thus noSQL was used to provide a powerful means to store portions of the data that provided users with search capabilities on each simulation's traits through a web application. Based on the user selection

  13. A Pilot Study: Comparison of Arm Versus Ankle Noninvasive Blood Pressure Measurement at 2 Different Levels of Backrest Elevation.

    Science.gov (United States)

    Henley, Nicole; Quatrara, Beth D; Conaway, Mark

    2015-01-01

    Standard practice for obtaining noninvasive blood pressure includes arm blood pressure (BP) cuff placement at the level of the heart; however, some critical care patients cannot have BPs taken in their arm because of various conditions, and ankle BPs are frequently used as substitutes. The aim of this study was to determine if there was a significant variation between upper arm and ankle BP measurements at different backrest elevations with consideration of peripheral edema factors. After institutional review board approval was obtained, a pilot study was implemented to evaluate noninvasive BP measurements of the arm and ankle with backrest elevation at 0° and 30° in a population of medical intensive care unit patients. Participants served as their own controls and were randomly assigned to left- versus right-side BP readings. Data were also collected on presence of arm versus ankle edema. A total of 30 participants enrolled in the study and provided 120 BP measurements. Blood pressure readings were analyzed in terms of diastolic and systolic findings as well as backrest elevations and edema presence. Thirteen participants presented with either arm or ankle edema. There was a statistical difference between the systolic arm and ankle BP measurements in the 0° (P = .008) and 30° (P arm and ankle diastolic BP is greater for participants without ankle edema (P = .038, r = 0.54) than for participants with ankle edema (P = .650, r = 0.14), but it is not statistically significant (P = .47). Even though ankle BPs are often substituted for arm BPs when the arm is unable to be used, ankle BPs and arm BPs are not interchangeable. Adjustments in backrest elevation and considerations of edema do not normalize the differences. Blood pressures obtained from the ankle are significantly greater than those obtained from the arm. This information needs to be considered when arms are not available and legs are used as surrogates for the upper arm.

  14. Establishment of one-axis vibration test system for measurement of biodynamic response of human hand-arm system.

    Science.gov (United States)

    Shibata, Nobuyuki; Hosoya, Naoki; Maeda, Setsuo

    2008-12-01

    Prolonged exposure to hand-arm vibration (HAV) due to use of hand-held power tools leads to an increased occurrence of symptoms of disorders in the vascular, neurological, and osteo-articular systems of the upper limbs called hand-arm vibration syndrome (HAVS). Biodynamic responses of the hand-arm system to vibration can be suggestive parameters that give us better assessment of exposure to HAV and fundamental data for design of low-vibration-exposure power tools. Recently, a single axis hand-arm vibration system has been installed in the Japan National Institute of Occupational Safety and Health (NIOSH). The aims of this study were to obtain the fundamental dynamic characteristics of an instrumented handle and to validate the performance and measurement accuracy of the system applied to dynamic response measurement. A pseudo-random vibration signal with a frequency range of 5-1,250 Hz and a power spectrum density of 1.0 (m/s2)2/Hz was used in this study. First the dynamic response of the instrumented handle without any weight was measured. After this measurement, the dynamic response measurement of the handle with weights mounted on the handle was performed. The apparent mass of a weight itself was obtained by using the mass cancellation method. The mass of the measuring cap on the instrumented handle was well compensated by using the mass cancellation method. Based on the 10% error tolerance, this handle can reliably measure the dynamic response represented by an apparent mass with a minimum weight of 2.0 g in a frequency range of 10.0 to 1,000 Hz. A marked increase in the AM magnitude of the weights of 15 g and 20 g in frequency ranges greater than 800 Hz is attributed not to the fundamental resonance frequency of the handle with weights, but to the fixation of the weight to the measuring cap. In this aspect, the peak of the AM magnitude can be reduced and hence should not be an obstacle to the biodynamic response measurement of the human hand-arm system. On the

  15. ARM Data File Standards Version: 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kehoe, Kenneth [University of Oklahoma; Beus, Sherman [Pacific Northwest National Laboratory; Cialella, Alice [Brookhaven National Laboratory; Collis, Scott [Argonne National Laboratory; Ermold, Brian [Pacific Northwest National Laboratory; Perez, Robin [State University of New York, Albany; Shamblin, Stefanie [Oak Ridge National Laboratory; Sivaraman, Chitra [Pacific Northwest National Laboratory; Jensen, Mike [Brookhaven National Laboratory; McCord, Raymond [Oak Ridge National Laboratory; McCoy, Renata [Sandia National Laboratories; Moore, Sean [Alliant Techsystems, Inc.; Monroe, Justin [University of Oklahoma; Perkins, Brad [Los Alamos National Laboratory; Shippert, Tim [Pacific Northwest National Laboratory

    2014-04-01

    The Atmospheric Radiation Measurement (ARM) Climate Research Facility performs routine in situ and remote-sensing observations to provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes. The result is a diverse data sets containing observational and derived data, currently accumulating at a rate of 30 TB of data and 150,000 different files per month (http://www.archive.arm.gov/stats/storage2.html). Continuing the current processing while scaling this to even larger sizes is extremely important to the ARM Facility and requires consistent metadata and data standards. The standards described in this document will enable development of automated analysis and discovery tools for the ever-growing volumes of data. It also will enable consistent analysis of the multiyear data, allow for development of automated monitoring and data health status tools, and facilitate development of future capabilities for delivering data on demand that can be tailored explicitly to user needs. This analysis ability will only be possible if the data follows a minimum set of standards. This document proposes a hierarchy that includes required and recommended standards.

  16. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  17. ARM Climate Research Facility Quarterly Value-Added Product Report

    Energy Technology Data Exchange (ETDEWEB)

    Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2016-10-01

    The purpose of this report is to provide a concise status update for Value-Added Products (VAPs) implemented by the Atmospheric Radiation Measurement (ARM) Climate Research Facility. The report is divided into the following sections: (1) new VAPs for which development has begun; (2) progress on existing VAPs; (3) future VAPs that have been recently approved; (4) other work that leads to a VAP; (5) top requested VAPs from the ARM Data Archive; and (6) a summary of VAP and data releases to production and evaluation. New information is highlighted in blue text. New information about processed data by the developer is highlighted in red text. The upcoming milestones and dates are highlighted in green.

  18. Radiation protection, measurements and methods

    International Nuclear Information System (INIS)

    1983-06-01

    The introductory lectures discuss subjects such as radiation protection principles and appropriate measuring techniques; methods, quantities and units in radiation protection measurement; technical equipment; national and international radiation protection standards. The papers presented at the various sessions deal with: Dosimetry of external radiation (27 papers); Working environment monitoring and emission monitoring (21 contributions); Environmental monitoring (19 papers); Incorporation monitoring (9 papers); Detection limits (4 papers); Non-ionizing radiation, measurement of body dose and biological dosimetry (10 papers). All 94 contributions (lectures, compacts and posters) are retrievable as separate records. (HP) [de

  19. Processing ARM VAP data on an AWS cluster

    Science.gov (United States)

    Martin, T.; Macduff, M.; Shippert, T.

    2017-12-01

    The Atmospheric Radiation Measurement (ARM) Data Management Facility (DMF) manages over 18,000 processes and 1.3 TB of data each day. This includes many Value Added Products (VAPs) that make use of multiple instruments to produce the derived products that are scientifically relevant. A thermodynamic and cloud profile VAP is being developed to provide input to the ARM Large-eddy simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) project (https://www.arm.gov/capabilities/vaps/lasso-122) . This algorithm is CPU intensive and the processing requirements exceeded the available DMF computing capacity. Amazon Web Service (AWS) along with CfnCluster was investigated to see how it would perform. This cluster environment is cost effective and scales dynamically based on demand. We were able to take advantage of autoscaling which allowed the cluster to grow and shrink based on the size of the processing queue. We also were able to take advantage of the Amazon Web Services spot market to further reduce the cost. Our test was very successful and found that cloud resources can be used to efficiently and effectively process time series data. This poster will present the resources and methodology used to successfully run the algorithm.

  20. The ARM-GCSS Intercomparison Study of Single-Column Models and Cloud System Models

    International Nuclear Information System (INIS)

    Cederwall, R.T.; Rodriques, D.J.; Krueger, S.K.; Randall, D.A.

    1999-01-01

    The Single-Column Model (SCM) Working Group (WC) and the Cloud Working Group (CWG) in the Atmospheric Radiation Measurement (ARM) Program have begun a collaboration with the GEWEX Cloud System Study (GCSS) WGs. The forcing data sets derived from the special ARM radiosonde measurements made during the SCM Intensive Observation Periods (IOPs), the wealth of cloud and related data sets collected by the ARM Program, and the ARM infrastructure support of the SCM WG are of great value to GCSS. In return, GCSS brings the efforts of an international group of cloud system modelers to bear on ARM data sets and ARM-related scientific questions. The first major activity of the ARM-GCSS collaboration is a model intercomparison study involving SCMs and cloud system models (CSMs), also known as cloud-resolving or cloud-ensemble models. The SCM methodologies developed in the ARM Program have matured to the point where an intercomparison will help identify the strengths and weaknesses of various approaches. CSM simulations will bring much additional information about clouds to evaluate cloud parameterizations used in the SCMs. CSMs and SCMs have been compared successfully in previous GCSS intercomparison studies for tropical conditions. The ARM Southern Great Plains (SGP) site offers an opportunity for GCSS to test their models in continental, mid-latitude conditions. The Summer 1997 SCM IOP has been chosen since it provides a wide range of summertime weather events that will be a challenging test of these models

  1. A Climatology of Midlatitude Continental Clouds from the ARM SGP Site. Part I; Low-Level Cloud Macrophysical, Microphysical, and Radiative Properties

    Science.gov (United States)

    Dong, Xiquan; Minnis, Patrick; Xi, Baike

    2005-01-01

    A record of single-layer and overcast low cloud (stratus) properties has been generated using approximately 4000 hours of data collected from January 1997 to December 2002 at the Atmospheric Radiation Measurement (ARM) Southern Great Plains Central Facility (SCF). The cloud properties include liquid-phase and liquid-dominant, mixed-phase, low cloud macrophysical, microphysical, and radiative properties including cloud-base and -top heights and temperatures, and cloud physical thickness derived from a ground-based radar and lidar pair, and rawinsonde sounding; cloud liquid water path (LWP) and content (LWC), and cloud-droplet effective radius (r(sub e)) and number concentration (N) derived from the macrophysical properties and radiometer data; and cloud optical depth (tau), effective solar transmission (gamma), and cloud/top-of-atmosphere albedos (R(sub cldy)/R(sub TOA)) derived from Eppley precision spectral pyranometer measurements. The cloud properties were analyzed in terms of their seasonal, monthly, and hourly variations. In general, more stratus clouds occur during winter and spring than in summer. Cloud-layer altitudes and physical thicknesses were higher and greater in summer than in winter with averaged physical thicknesses of 0.85 km and 0.73 km for day and night, respectively. The seasonal variations of LWP, LWC, N. tau, R(sub cldy), and R(sub TOA) basically follow the same pattern with maxima and minima during winter and summer, respectively. There is no significant variation in mean r(sub e), however, despite a summertime peak in aerosol loading, Although a considerable degree of variability exists, the 6-yr average values of LWP, LWC, r(sub e), N, tau, gamma, R(sub cldy) and R(sub TOA) are 150 gm(exp -2) (138), 0.245 gm(exp -3) (0.268), 8.7 micrometers (8.5), 213 cm(exp -3) (238), 26.8 (24.8), 0.331, 0.672, 0.563 for daytime (nighttime). A new conceptual model of midlatitude continental low clouds at the ARM SGP site has been developed from this study

  2. Inter-arm Differences in Simultaneous Blood Pressure Measurements in Ambulatory Patients without Cardiovascular Diseases.

    Science.gov (United States)

    Kim, Kyoung Bog; Oh, Mi Kyeong; Kim, Haa Gyoung; Ki, Ji Hoon; Lee, Soo Hee; Kim, Su Min

    2013-03-01

    It has traditionally been known that there is normally a difference in blood pressure (BP) between the two arms; there is at least 20 mm Hg difference in the systolic blood pressure (SBP) and 10 mm Hg difference in the diastolic blood pressure (DBP). However, recent epidemiologic studies have shown that there are between-arm differences of arm differences in simultaneous BP measurements obtained from ambulatory patients without cardiovascular diseases and to identify the factors associated these differences. We examined 464 patients who visited the outpatient clinic of Gangneung Asan Hospital clinical department. For the current analysis, we excluded patients with ischemic heart disease, stroke, arrhythmia, congestive heart failure, or hyperthyroidism. Simultaneous BP measurements were obtained using the Omron MX3 BP monitor in both arms. The inter-arm difference (IAD) in BP was expressed as the relative difference (right-arm BP [R] minus left-arm BP [L]: R - L) and the absolute difference (|R - L|). The mean absolute IAD in SBP and DBP were 3.19 ± 2.38 and 2.41 ± 1.59 mm Hg, respectively, in men and 2.61 ± 2.18 and 2.25 ± 2.01 mm Hg, respectively, in women. In men, there were 83.8% of patients with the IAD in SBP of ≤ 6 mm Hg, 98.1% with the IAD in SBP of ≤ 10 mm Hg, 96.5% with the IAD in DBP of ≤ 6 mm Hg and 0% with the IAD in DBP of > 10 mm Hg. In women, 89.6% of patients had IAD in SBP of ≤ 6 mm Hg, 92.1% with IAD in DBP of ≤ 6 mm Hg, and 0% with IAD in SBP of > 10 mm Hg or IAD in DBP of > 10 mm Hg. Gangneung Asan Hospital clinical series of patients showed that the absolute IAD in SBP had a significant correlation with cardiovascular risk factors such as the 10-year Framingham cardiac risk scores and higher BP in men and higher BP in women. However, the absolute IAD in SBP and DBP had no significant correlation with the age, obesity, smoking, drinking, hyperlipidemia, diabetes, metabolic syndrome, and renal function. Our results showed that there

  3. Hello to Arms

    Science.gov (United States)

    2005-01-01

    This image highlights the hidden spiral arms (blue) that were discovered around the nearby galaxy NGC 4625 by the ultraviolet eyes of NASA's Galaxy Evolution Explorer. The image is composed of ultraviolet and visible-light data, from the Galaxy Evolution Explorer and the California Institute of Technology's Digitized Sky Survey, respectively. Near-ultraviolet light is colored green; far-ultraviolet light is colored blue; and optical light is colored red. As the image demonstrates, the lengthy spiral arms are nearly invisible when viewed in optical light while bright in ultraviolet. This is because they are bustling with hot, newborn stars that radiate primarily ultraviolet light. The youthful arms are also very long, stretching out to a distance four times the size of the galaxy's core. They are part of the largest ultraviolet galactic disk discovered so far. Located 31 million light-years away in the constellation Canes Venatici, NGC 4625 is the closest galaxy ever seen with such a young halo of arms. It is slightly smaller than our Milky Way, both in size and mass. However, the fact that this galaxy's disk is forming stars very actively suggests that it might evolve into a more massive and mature galaxy resembling our own. The armless companion galaxy seen below NGC 4625 is called NGC 4618. Astronomers do not know why it lacks arms but speculate that it may have triggered the development of arms in NGC 4625.

  4. Atmospheric radiation measurement program facilities newsletter, September 2001.; TOPICAL

    International Nuclear Information System (INIS)

    Holdridge, D. J.

    2001-01-01

    Our Changing Climate-Is our climate really changing? How do we measure climate change? How can we predict what Earth's climate will be like for generations to come? One focus of the Atmospheric Radiation Measurement (ARM) Program is to improve scientific climate models enough to achieve reliable regional prediction of future climate. According to the Environmental Protection Agency (EPA), the global mean surface temperature has increased by 0.5-1.0 F since the late 19th century. The 20th century's 10 warmest years all occurred in the last 15 years of the century, with 1998 being the warmest year of record. The global mean surface temperature is measured by a network of temperature-sensing instruments distributed around the world, including ships, ocean buoys, and weather stations on land. The data from this network are retrieved and analyzed by various organizations, including the National Aeronautics and Space Administration, the National Oceanic and Atmospheric Administration, and the World Meteorological Organization. Worldwide temperature records date back to 1860. To reconstruct Earth's temperature history before 1860, scientists use limited temperature records, along with proxy indicators such as tree rings, pollen records, and analysis of air frozen in ancient ice. The solar energy received from the sun drives Earth's weather and climate. Some of this energy is reflected and filtered by the atmosphere, but most is absorbed by Earth's surface. The absorbed solar radiation warms the surface and is re-radiated as heat energy into the atmosphere. Some atmospheric gases, called greenhouse gases, trap some of the re-emitted heat, keeping the surface temperature regulated and suitable for sustaining life. Although the greenhouse effect is natural, some evidence indicates that human activities are producing increased levels of some greenhouse gases such as carbon dioxide, methane, and nitrous oxide. Scientists believe that the combustion of fossil fuels is

  5. Radiation Calibration Measurements

    International Nuclear Information System (INIS)

    Omondi, C.

    2017-01-01

    KEBS Radiation Dosimetry mandate are: Custodian of Kenya Standards on Ionizing radiation, Ensure traceability to International System (SI ) and Calibration radiation equipment. RAF 8/040 on Radioisotope applications for troubleshooting and optimizing industrial process established Radiotracer Laboratory objective is to introduce and implement radiotracer technique for problem solving of industrial challenges. Gamma ray scanning technique applied is to Locate blockages, Locate liquid in vapor lines, Locate areas of lost refractory or lining in a pipe and Measure flowing densities. Equipment used for diagnostic and radiation protection must be calibrated to ensure Accuracy and Traceability

  6. Radiation measurement practice for understanding statistical fluctuation of radiation count using natural radiation sources

    International Nuclear Information System (INIS)

    Kawano, Takao

    2014-01-01

    It is known that radiation is detected at random and the radiation counts fluctuate statistically. In the present study, a radiation measurement experiment was performed to understand the randomness and statistical fluctuation of radiation counts. In the measurement, three natural radiation sources were used. The sources were fabricated from potassium chloride chemicals, chemical fertilizers and kelps. These materials contain naturally occurring potassium-40 that is a radionuclide. From high schools, junior high schools and elementary schools, nine teachers participated to the radiation measurement experiment. Each participant measured the 1-min integration counts of radiation five times using GM survey meters, and 45 sets of data were obtained for the respective natural radiation sources. It was found that the frequency of occurrence of radiation counts was distributed according to a Gaussian distribution curve, although the obtained 45 data sets of radiation counts superficially looked to be fluctuating meaninglessly. (author)

  7. Comparison of mesoscale model and tower measurements of surface fluxes during Winter Icing and Storms Program/Atmospheric Radiation Measurement 91

    International Nuclear Information System (INIS)

    Oncley, S.P.; Dudhia, J.

    1994-01-01

    This study is an evaluation of the ability of the Pennsylvania State University/National Center for Atmospheric Research (NCAR) mesoscale model (MM4) to determine surface fluxes to see if measured fluxes should be assimilated into model runs. Fluxes were compared from a high-resolution (5 km grid spacing) MM4 run during one day of the Winter Icing and Storms Programs/Atmospheric Radiation Measurement (WISP/ARM) experiment (over NE Colorado in winter 1991) with direct flux measurements made from a tower over a representative site by a three-dimensional sonic anemometer and fast response temperature and humidity sensors. This tower was part of the NCAR Atmosphere-Surface Turbulent Exchange Research (ASTER) facility. Also, mean values were compared to check whether any differences were due to the model parameterization or model variables

  8. Using a simple apparatus to measure direct and diffuse photosynthetically active radiation at remote locations.

    Directory of Open Access Journals (Sweden)

    Michael J Cruse

    Full Text Available Plant canopy interception of photosynthetically active radiation (PAR drives carbon dioxide (CO2, water and energy cycling in the soil-plant-atmosphere system. Quantifying intercepted PAR requires accurate measurements of total incident PAR above canopies and direct beam and diffuse PAR components. While some regional data sets include these data, e.g. from Atmospheric Radiation Measurement (ARM Program sites, they are not often applicable to local research sites because of the variable nature (spatial and temporal of environmental variables that influence incoming PAR. Currently available instrumentation that measures diffuse and direct beam radiation separately can be cost prohibitive and require frequent adjustments. Alternatively, generalized empirical relationships that relate atmospheric variables and radiation components can be used but require assumptions that increase the potential for error. Our goal here was to construct and test a cheaper, highly portable instrument alternative that could be used at remote field sites to measure total, diffuse and direct beam PAR for extended time periods without supervision. The apparatus tested here uses a fabricated, solar powered rotating shadowband and other commercially available parts to collect continuous hourly PAR data. Measurements of total incident PAR had nearly a one-to-one relationship with total incident radiation measurements taken at the same research site by an unobstructed point quantum sensor. Additionally, measurements of diffuse PAR compared favorably with modeled estimates from previously published data, but displayed significant differences that were attributed to the important influence of rapidly changing local environmental conditions. The cost of the system is about 50% less than comparable commercially available systems that require periodic, but not continual adjustments. Overall, the data produced using this apparatus indicates that this instrumentation has the

  9. Stature and Its Estimation Utilizing Arm Span Measurements of both gender Adolescents from Southern Region in Kosovo

    Directory of Open Access Journals (Sweden)

    Fitim Arifi

    2018-06-01

    Full Text Available This study is based on measurements of Southern region Kosovan adolescents. The aim of this study was to examine the stature of adolescents from Southern region as well relationship between arm span and stature in both Kosovar genders. A total measured subject participated in this research was 225 out of which (105 girls and 120 boys, females average of age is 18.36±0.50 years old (range 18-20 years and for male 18.40±0.55 years old (range 18-20 years.The anthropometric measurements were done by trained people and were taken according to the ISAK manual. Relationship between stature and arm span has been analyzed by the simple correlation coeffi cient at a 95% confi dence interval. The linear regression analysis was carried out to examine extent to which arm span can reliably predict of stature. Statistical importance was placed at level p<0.05. As a result anthropometric measurements for both sexes showed that the average of stature for boys adolescents from Southern region are 178.60±5.73 centimeters and have the arm span average of 180.92±6.92 centimeters, while girls from Southern 165.33±4.45 centimeters tall, and have the arm span average of 165.60±6.03 centimeters. The results have shown that the arm span was estimated as a reliable indicator of stature assessment to the both genders adolescents from Southern region of Kosovo population. This study also confi rms the necessity for developing separate height models for each region in Kosovo.

  10. Measurements of the LHCb software stack on the ARM architecture

    International Nuclear Information System (INIS)

    Kartik, S Vijay; Couturier, Ben; Clemencic, Marco; Neufeld, Niko

    2014-01-01

    The ARM architecture is a power-efficient design that is used in most processors in mobile devices all around the world today since they provide reasonable compute performance per watt. The current LHCb software stack is designed (and thus expected) to build and run on machines with the x86/x86 6 4 architecture. This paper outlines the process of measuring the performance of the LHCb software stack on the ARM architecture – specifically, the ARMv7 architecture on Cortex-A9 processors from NVIDIA and on full-fledged ARM servers with chipsets from Calxeda – and makes comparisons with the performance on x86 6 4 architectures on the Intel Xeon L5520/X5650 and AMD Opteron 6272. The paper emphasises the aspects of performance per core with respect to the power drawn by the compute nodes for the given performance – this ensures a fair real-world comparison with much more 'powerful' Intel/AMD processors. The comparisons of these real workloads in the context of LHCb are also complemented with the standard synthetic benchmarks HEPSPEC and Coremark. The pitfalls and solutions for the non-trivial task of porting the source code to build for the ARMv7 instruction set are presented. The specific changes in the build process needed for ARM-specific portions of the software stack are described, to serve as pointers for further attempts taken up by other groups in this direction. Cases where architecture-specific tweaks at the assembler lever (both in ROOT and the LHCb software stack) were needed for a successful compile are detailed – these cases are good indicators of where/how the software stack as well as the build system can be made more portable and multi-arch friendly. The experience gained from the tasks described in this paper are intended to i) assist in making an informed choice about ARM-based server solutions as a feasible low-power alternative to the current compute nodes, and ii) revisit the software design and build system for portability and

  11. Thermoluminescent measurement in space radiation dosimetry

    International Nuclear Information System (INIS)

    Chen Mei; Qi Zhangnian; Li Xianggao; Huang Zengxin; Jia Xianghong; Wang Genliang

    1999-01-01

    The author introduced the space radiation environment and the application of thermoluminescent measurement in space radiation dosimetry. Space ionization radiation is charged particles radiation. Space radiation dosimetry was developed for protecting astronauts against space radiation. Thermoluminescent measurement is an excellent method used in the spaceship cabin. Also the authors mentioned the recent works here

  12. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  13. [Determination of arm circumference for correct measurement of blood pressure. Results of an intervention study].

    Science.gov (United States)

    Oliveras Puig, A; Dalfó-Pibernat, A; Jdid Rosàs, N; Mayor Isaac, E; Pérez-Romero, L; Gibert Llorach, E; Dalfó-Baqué, A

    2015-01-01

    To assess the effectiveness of an intervention to promote standardized arm circumference measurement as way to choose appropriate cuff size to measure blood pressure. A before-after intervention study was performed in a basic health care area in Barcelona. Doctors, nurses and pharmacy staff participated by filling out an anonymous self-administered questionnaire pre- and post-intervention (3m). Variables included: demographics, type of professional, years since they finished their studies, availability of different cuff sizes, if arm circumference measurement were obtained or not, knowledge about the cutoff values for each cuff size and type of blood pressure monitor. The written results were given to the participants and presented in sessions. Pre- and post-intervention: 74.3 and 67.3% answered the questionnaires (P=ns), respectively. Determination of arm circumference varied from 1.3 to 19.1% (P=.009). A total of 37.3% and 44.1% declared that they had 2 or more available cuff sizes (P=ns). Knowledge about the correct measurement of the cuffs was 2.7 to 33.8% regarding the standard cuff size (P=.0198) and 0 to 23.5% for obese subjects (P<.05). When more than one cuff was available, reasons for the choice went from: «making a rough guess» or «when velcro stops sticking» before and after the intervention. All blood pressure devices in our primary health care center were electronic and automatic as were those of the 9 pharmacies. The intervention increased the determination of arm circumference prior to the reading of the blood pressure and the knowledge about the cutoff interval for standard and obese cuff size after intervention. There was greater availability of different sized cuffs. Despite this, the choice of the appropriate cuff size was not made based on arm circumference. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  14. 3D Measurement of Forearm and Upper Arm during Throwing Motion using Body Mounted Sensor

    Science.gov (United States)

    Koda, Hideharu; Sagawa, Koichi; Kuroshima, Kouta; Tsukamoto, Toshiaki; Urita, Kazutaka; Ishibashi, Yasuyuki

    The aim of this study is to propose the measurement method of three-dimensional (3D) movement of forearm and upper arm during pitching motion of baseball using inertial sensors without serious consideration of sensor installation. Although high accuracy measurement of sports motion is achieved by using optical motion capture system at present, it has some disadvantages such as the calibration of cameras and limitation of measurement place. Whereas the proposed method for 3D measurement of pitching motion using body mounted sensors provides trajectory and orientation of upper arm by the integration of acceleration and angular velocity measured on upper limb. The trajectory of forearm is derived so that the elbow joint axis of forearm corresponds to that of upper arm. Spatial relation between upper limb and sensor system is obtained by performing predetermined movements of upper limb and utilizing angular velocity and gravitational acceleration. The integration error is modified so that the estimated final position, velocity and posture of upper limb agree with the actual ones. The experimental results of the measurement of pitching motion show that trajectories of shoulder, elbow and wrist estimated by the proposed method are highly correlated to those from the motion capture system within the estimation error of about 10 [%].

  15. Tc-99m-Human Serum Albumin Transit Time as a Measure of Arm Breast Cancer-Related Lymphedema

    DEFF Research Database (Denmark)

    Toyserkani, Navid M; Hvidsten, Svend; Tabatabaeifar, Siavosh

    2017-01-01

    34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent bilateral lymphoscintigraphy using intradermal injection in both hands of technetium-99m-labeled human serum albumin and sequential 5 min imaging for 5 hours. The mean transit time (MTT) in the arms was calculated...... based on time activity curves generated from injection site and arm regions. Visual lymphedema scoring was performed based on dermal backflow and lymph node presence. Excess arm volume was calculated from circumference measurements. RESULTS: The MTT (mean ± SD) was significantly longer in the lymphedema...

  16. Study on the method or reducing the operator's exposure dose from a C-Arm system

    International Nuclear Information System (INIS)

    Kim, Ki Sik; Song, Jong Nam; Kim, Seung Ok

    2016-01-01

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment

  17. Deviating measurements in radiation protection. Legal assessment of deviations in radiation protection measurements

    International Nuclear Information System (INIS)

    Hoegl, A.

    1996-01-01

    This study investigates how, from a legal point of view, deviations in radiation protection measurements should be treated in comparisons between measured results and limits stipulated by nuclear legislation or goods transport regulations. A case-by-case distinction is proposed which is based on the legal concequences of the respective measurement. Commentaries on nuclear law contain no references to the legal assessment of deviating measurements in radiation protection. The examples quoted in legal commentaries on civil and criminal proceedings of the way in which errors made in measurements for speed control and determinations of the alcohol content in the blood are to be taken into account, and a commentary on ozone legislation, are examined for analogies with radiation protection measurements. Leading cases in the nuclear field are evaluated in the light of the requirements applying in case of deviations in measurements. The final section summarizes the most important findings and conclusions. (orig.) [de

  18. Kinematics study and workspace analysis of an articulated robotic arm of a rpar

    International Nuclear Information System (INIS)

    Zeb, J.; Rashid, F.; Iqbal, N.

    2007-01-01

    An itinerant RPAR (Radiation Protection Assistant Robot) has been constructed to assist radiation workers in radiation area which are radiologically hazardous and beyond tile safe approach of radiation workers. The RPAR comprises of a cubicle tri- wheeled platform and a 4-DOF (Four Degree of Freedom) serial type articulated robotic arm. The movement of the platform is controlled by two differential wheeled driving systems. The Kinematics and Manipulator Jacobian of the end-effector (gripper) of the articulated robotic arm mounted on the RPAR were evaluated. The work space analyses of the articulated robotic arm have been carried out. The RPAR is helpful for surveillance of radiation zones, to pick and carry dropdown radioactive samples and sources, in routine radiological operations as well as during an emergency response to a radiological accident. The performance of the RPAR was found satisfactory. (author)

  19. ARM Data File Standards Version 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Palanisamy, Giri [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-05-01

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility performs routine in situ and remote-sensing observations to provide a detailed and accurate description of the Earth atmosphere in diverse climate regimes. The result is a huge archive of diverse data sets containing observational and derived data, currently accumulating at a rate of 30 terabytes (TB) of data and 150,000 different files per month (http://www.archive.arm.gov/stats/). Continuing the current processing while scaling this to even larger sizes is extremely important to the ARM Facility and requires consistent metadata and data standards. The standards described in this document will enable development of automated analysis and discovery tools for the ever growing data volumes. It will enable consistent analysis of the multiyear data, allow for development of automated monitoring and data health status tools, and allow future capabilities of delivering data on demand that can be tailored explicitly for the user needs. This analysis ability will only be possible if the data follows a minimum set of standards. This document proposes a hierarchy of required and recommended standards.

  20. An ARM Mobile Facility Designed for Marine Deployments

    Science.gov (United States)

    Wiscombe, W. J.

    2007-05-01

    The U.S. Dept. of Energy's ARM (Atmospheric Radiation Measurements) Program is designing a Mobile Facility exclusively for marine deployments. This marine facility is patterned after ARM's land Mobile Facility, which had its inaugural deployment at Point Reyes, California, in 2005, followed by deployments to Niger in 2006 and Germany in 2007 (ongoing), and a planned deployment to China in 2008. These facilities are primarily intended for the study of clouds, radiation, aerosols, and surface processes with a goal to include these processes accurately in climate models. They are preferably embedded within larger field campaigns which provide context. They carry extensive instrumentation (in several large containers) including: cloud radar, lidar, microwave radiometers, infrared spectrometers, broadband and narrowband radiometers, sonde-launching facilities, extensive surface aerosol measurements, sky imagers, and surface latent and sensible heat flux devices. ARM's Mobile Facilities are designed for 6-10 month deployments in order to capture climatically-relevant datasets. They are available to any scientist, U.S. or international, who wishes to submit a proposal during the annual Spring call. The marine facility will be adapted to, and ruggedized for, the harsh marine environment and will add a scanning two-frequency radar, a boundary-layer wind profiler, a shortwave spectrometer, and aerosol instrumentation adapted to typical marine aerosols like sea salt. Plans also include the use of roving small UAVs, automated small boats, and undersea autonomous vehicles in order to address the point-to-area-average problem which is so crucial for informing climate models. Initial deployments are planned for small islands in climatically- interesting cloud regimes, followed by deployments on oceanic platforms (like decommissioned oil rigs and the quasi-permanent platform of this session's title) and eventually on large ships like car carriers plying routine routes.

  1. Relationship between Arm Span Measurements and Body Height in Dinaric Alpes Population: a Systematic Review

    Directory of Open Access Journals (Sweden)

    Bojan Masanovic

    2017-08-01

    Full Text Available Several researches have reported the benefit of using various body parameters in predicting standing height, and arm span happened to be one of the most reliable ones in adults. On the other hand, it is well-known the tallness and body proportions are specific in the area that are covered by Dinaric Alpes. Therefore, the purpose of this study was to investigate the potential relationship between arm span measurements and body height in Dinaric Alpes population. The most visible electronic database (Google Scholar was searched for original research articles available until September 2017. Then research findings were summarized and relationship between arm span measurements and body height in Dinaric Alpes population were identified, as well as areas of future research were recommended. The assessment of body height using various anthropometric measures is very typical from the past centuries and it has been attempted to be studied by many researchers. However, it is important to underline that the arm span has been obtained as the most reliable body indicator for predicting the true height of an individual. However, the studies sampled with the populations lived at Dinaric Alpes mountains have specific estimates. Therefore, all above-mentioned have confirmed the necessity for developing separate body height models for each population on account of ethnic as well as regional differences.

  2. Ultraviolet radiation, measurements and safety evaluations for radiation protection purposes

    International Nuclear Information System (INIS)

    Witew, B.; Fischer, P.G.

    1983-01-01

    In order to evaluate the effects of ultraviolet radiation, one has to study that photobiologically effective radiation which induces a just measurable threshold reaction. For practical radiation protection, one has to determine the permissible duration of exposure at the end of which the threshold reaction is induced. This time limit is derived by means of spectral measurements and determination of radiation intensity. Detrimental photobiological effects can be avoided, and favourable effects optimized, by observing the time limit. Thus these measurements are used to determine the threshold at which the desired effects of ultraviolet radiation will be accompanied by unwanted effects or damage to persons, as for instance in the use of ultraviolet radiation for operating room sterilization, arc welding work, or cosmetic purposes. (orig.) [de

  3. Marine ARM GPCI Investigation of Clouds (MAGIC) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Ernie R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-12-01

    The Marine ARM GPCI Investigation of Clouds (MAGIC) field campaign, which deployed the second ARM Mobile Facility (AMF2) aboard the Horizon Lines cargo container ship Spirit as it ran its regular route between Los Angeles, California and Honolulu, Hawaii, measured properties of clouds and precipitation, aerosols, radiation, and atmospheric, meteorological, and oceanic conditions with the goal of obtaining statistics of these properties to achieve better understanding of the transition between stratocumulus and cumulus cloud regimes that occur in that region. This Sc-Cu transition is poorly represented in models, and a major reason for this is the lack of high-quality and comprehensive data that can be used to constrain, validate, and improve model representation of the transition. MAGIC consisted of 20 round trips between Los Angeles and Honolulu, and thus over three dozen transects through the transition, totaling nearly 200 days at sea between September, 2012 and October, 2013. During this time MAGIC collected a unique and unprecedented data set, including more than 550 successful radiosonde launches. An Intensive Observational Period (IOP) occurred in July, 2013 during which more detailed measurements of the atmospheric structure were made. MAGIC was very successful in its operations and overcame numerous logistical and technological challenges, clearly demonstrating the feasibility of a marine AMF2 deployment and the ability to make accurate measurements of clouds and precipitation, aerosols, and radiation while at sea.

  4. Proprioceptive Interaction between the Two Arms in a Single-Arm Pointing Task.

    Directory of Open Access Journals (Sweden)

    Kazuyoshi Kigawa

    Full Text Available Proprioceptive signals coming from both arms are used to determine the perceived position of one arm in a two-arm matching task. Here, we examined whether the perceived position of one arm is affected by proprioceptive signals from the other arm in a one-arm pointing task in which participants specified the perceived position of an unseen reference arm with an indicator paddle. Both arms were hidden from the participant's view throughout the study. In Experiment 1, with both arms placed in front of the body, the participants received 70-80 Hz vibration to the elbow flexors of the reference arm (= right arm to induce the illusion of elbow extension. This extension illusion was compared with that when the left arm elbow flexors were vibrated or not. The degree of the vibration-induced extension illusion of the right arm was reduced in the presence of left arm vibration. In Experiment 2, we found that this kinesthetic interaction between the two arms did not occur when the left arm was vibrated in an abducted position. In Experiment 3, the vibration-induced extension illusion of one arm was fully developed when this arm was placed at an abducted position, indicating that the brain receives increased proprioceptive input from a vibrated arm even if the arm was abducted. Our results suggest that proprioceptive interaction between the two arms occurs in a one-arm pointing task when the two arms are aligned with one another. The position sense of one arm measured using a pointer appears to include the influences of incoming information from the other arm when both arms were placed in front of the body and parallel to one another.

  5. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2015-01-01

    This fourth edition reflects recent major developments that have occurred in radiation detector materials, systems, and applications. It continues to provide the most practical and up-to-date introduction to radiation detector technology, proper measurement techniques, and analysis of results for engineers and scientists using radiation sources. New chapters emphasize the expanded use of radiation detection systems in nuclear non-proliferation, homeland security, and nuclear medicine. The book also discusses the correct ways to perform measurements following current health physics procedures.

  6. Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, S.; Nithiananthan, S.; Mirota, D. J.; Uneri, A.; Stayman, J. W.; Zbijewski, W.; Schmidgunst, C.; Kleinszig, G.; Khanna, A. J.; Siewerdsen, J. H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 (United States); Siemens Healthcare XP Division, Erlangen (Germany); Department of Orthopaedic Surgery, Johns Hopkins University, Baltimore, Maryland 21239 (United States); Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21202 and Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States)

    2011-08-15

    Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter

  7. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  8. ARM Aerial Facility ArcticShark Unmanned Aerial System

    Science.gov (United States)

    Schmid, B.; Hubbell, M.; Mei, F.; Carroll, P.; Mendoza, A.; Ireland, C.; Lewko, K.

    2017-12-01

    The TigerShark Block 3 XP-AR "ArcticShark" Unmanned Aerial System (UAS), developed and manufactured by Navmar Applied Sciences Corporation (NASC), is a single-prop, 60 hp rotary-engine platform with a wingspan of 6.5 m and Maximum Gross Takeoff Weight of 295 Kg. The ArcticShark is owned by the U.S. Department of Energy (DOE) and has been operated by Pacific Northwest National Laboratory (PNNL) since March 2017. The UAS will serve as an airborne atmospheric research observatory for DOE ARM, and, once fully operational, can be requested through ARM's annual call for proposals. The Arctic Shark is anticipated to measure a wide range of radiative, aerosol, and cloud properties using a variable instrument payload weighing up to 46 Kg. SATCOM-equipped, it is capable of taking measurements up to altitudes of 5.5 Km over ranges of up to 500 Km. The ArcticShark operates at airspeeds of 30 to 40 m/s, making it capable of slow sampling. With a full fuel load, its endurance exceeds 8 hours. The aircraft and its Mobile Operations Center (MOC) have been hardened specifically for operations in colder temperatures.ArcticShark's design facilitates rapid integration of various types of payloads. 2500 W of its 4000 W electrical systems is dedicated to payload servicing. It has an interior payload volume of almost 85 L and four wing-mounted pylons capable of carrying external probes. Its payload bay volume, electrical power, payload capacity, and flight characteristics enable the ArcticShark to accommodate multiple combinations of payloads in numerous configurations. Many instruments will be provided by the ARM Aerial Facility (AAF), but other organizations may eventually propose instrumentation for specific campaigns. AAF-provided measurement capabilities will include the following atmospheric state and thermodynamics: temperature, pressure, winds; gases: H2O and CO2; up- and down-welling broadband infrared and visible radiation; surface temperature; aerosol number concentration

  9. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    Directory of Open Access Journals (Sweden)

    Chien-Lun Hou

    2011-02-01

    Full Text Available In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm.

  10. Solar and infrared radiation measurements

    CERN Document Server

    Vignola, Frank; Michalsky, Joseph

    2012-01-01

    The rather specialized field of solar and infrared radiation measurement has become more and more important in the face of growing demands by the renewable energy and climate change research communities for data that are more accurate and have increased temporal and spatial resolution. Updating decades of acquired knowledge in the field, Solar and Infrared Radiation Measurements details the strengths and weaknesses of instruments used to conduct such solar and infrared radiation measurements. Topics covered include: Radiometer design and performance Equipment calibration, installation, operati

  11. Design of the CART data system for the US Department of Energy's ARM Program

    International Nuclear Information System (INIS)

    Melton, R.B.; Campbell, A.P.; Edwards, D.M.; Kanciruk, P.; Tichler, J.L.

    1991-01-01

    The Department of Energy (DOE) has initiated a major atmospheric research effort to reduce the uncertainties found in general circulation and other models due to the effects of clouds and radiation. The objective of the Atmospheric Radiation Measurement Program (ARM) is to provide an experimental testbed for the study of important atmospheric effects, particularly cloud and radiative processes, and testing parameterizations of the processes for use in atmospheric models. This experimental testbed, known as the Clouds and Radiation Testbed (CART), will include a complex data system, the CART Data Environment (CDE). The major functions of the CDE will be to: acquire environments from instruments and external data sources; perform quality assessments of the data streams; create data streams of known quality to be used as model input compared to model output; execute the models and capture their predictions; and make data streams associated with model tests available to ARM investigators in near real-time. The CDE will also be expected to capture ancillary information (''meta-data'') associated with the data streams, provide data management facilities for design of ARM experiments, and provide for archival data storage. The first section of this paper presents background information on CART. Next the process for the functional design of the system is described, the functional requirements summarized, and the conceptual architecture of the CDE is presented. Finally, the status of the CDE design activities is summarized, and major technical challenges are discussed

  12. ARM/GCSS/SPARC TWP-ICE CRM Intercomparison Study

    Science.gov (United States)

    Fridlind, Ann; Ackerman, Andrew; Petch, Jon; Field, Paul; Hill, Adrian; McFarquhar, Greg; Xie, Shaocheng; Zhang, Minghua

    2010-01-01

    Specifications are provided for running a cloud-resolving model (CRM) and submitting results in a standardized format for inclusion in a n intercomparison study and archiving for public access. The simulated case study is based on measurements obtained during the 2006 Tropical Warm Pool - International Cloud Experiment (TWP-ICE) led by the U. S. department of Energy Atmospheric Radiation Measurement (ARM) program. The modeling intercomparison study is based on objectives developed in concert with the Stratospheric Processes And their Role in Climate (SPARC) program and the GEWEX cloud system study (GCSS) program. The Global Energy and Water Cycle Experiment (GEWEX) is a core project of the World Climate Research PRogramme (WCRP).

  13. Status of radiation-based measurement technology

    International Nuclear Information System (INIS)

    Moon, B. S.; Lee, J. W.; Chung, C. E.; Hong, S. B.; Kim, J. T.; Park, W. M.; Kim, J. Y.

    1999-03-01

    This report describes the status of measurement equipment using radiation source and new technologies in this field. This report includes the development status in Korea together with a brief description of the technology development and application status in ten countries including France, America, and Japan. Also this report describes technical factors related to radiation-based measurement and trends of new technologies. Measurement principles are also described for the equipment that is widely used among radiation-based measurement, such as level measurement, density measurement, basis weight measurement, moisture measurement, and thickness measurement. (author). 7 refs., 2 tabs., 21 figs

  14. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  15. Biomarkers specific to densely-ionising (high LET) radiations

    International Nuclear Information System (INIS)

    Brenner, D.J.; Okladnikova, N.; Hande, P.; Burak, L.; Geard, C.R.; Azizova, T.

    2001-01-01

    There have been several suggestions of biomarkers that are specific to high LET radiation. Such a biomarker could significantly increase the power of epidemiological studies of individuals exposed to densely-ionising radiations such as alpha particles (e.g. radon, plutonium workers, individuals exposed to depleted uranium) or neutrons (e.g. radiation workers, airline personnel). We discuss here a potentially powerful high LET biomarker (the H value) which is the ratio of induced inter-chromosomal aberrations to intra-arm aberrations. Both theoretical and experimental studies have suggested that this ratio should differ by a factor of about three between high LET radiation and any other likely clastogen, and will yield more discrimination than the previously suggested F value (ratio of inter-chromosomal aberrations to intra-chromosomal inter-arm aberrations). Evidence of the long-term stability of such chromosomal biomarkers has also been generated. Because these stable intra-arm and inter-chromosomal aberrations are (1) frequent and (2) measurable at long times after exposure, this H value appears to be a practical biomarker of high LET exposure, and several in vitro studies have confirmed the approach for unstable aberrations. The approach is currently being tested in a population of Russian radiation workers exposed several decades ago to high- or low LET radiation. (author)

  16. ARM Cloud Radar Simulator Package for Global Climate Models Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuying [North Carolina State Univ., Raleigh, NC (United States); Xie, Shaocheng [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-05-01

    It has been challenging to directly compare U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility ground-based cloud radar measurements with climate model output because of limitations or features of the observing processes and the spatial gap between model and the single-point measurements. To facilitate the use of ARM radar data in numerical models, an ARM cloud radar simulator was developed to converts model data into pseudo-ARM cloud radar observations that mimic the instrument view of a narrow atmospheric column (as compared to a large global climate model [GCM] grid-cell), thus allowing meaningful comparison between model output and ARM cloud observations. The ARM cloud radar simulator value-added product (VAP) was developed based on the CloudSat simulator contained in the community satellite simulator package, the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package (COSP) (Bodas-Salcedo et al., 2011), which has been widely used in climate model evaluation with satellite data (Klein et al., 2013, Zhang et al., 2010). The essential part of the CloudSat simulator is the QuickBeam radar simulator that is used to produce CloudSat-like radar reflectivity, but is capable of simulating reflectivity for other radars (Marchand et al., 2009; Haynes et al., 2007). Adapting QuickBeam to the ARM cloud radar simulator within COSP required two primary changes: one was to set the frequency to 35 GHz for the ARM Ka-band cloud radar, as opposed to 94 GHz used for the CloudSat W-band radar, and the second was to invert the view from the ground to space so as to attenuate the beam correctly. In addition, the ARM cloud radar simulator uses a finer vertical resolution (100 m compared to 500 m for CloudSat) to resolve the more detailed structure of clouds captured by the ARM radars. The ARM simulator has been developed following the COSP workflow (Figure 1) and using the capabilities available in COSP

  17. Nuclear instrumentation for radiation measurement

    International Nuclear Information System (INIS)

    Madan, V.K.

    2012-01-01

    Nuclear radiation cannot be detected by human senses. Nuclear detectors and associated electronics facilitate detection and measurement of different types of radiation like alpha particles, beta particles, gamma radiation, and detection of neutrons. Nuclear instrumentation has evolved greatly since the discovery of radioactivity. There has been tremendous advancement in detector technology, electronics, computer technology, and development of efficient algorithms and methods for spectral processing to extract precisely qualitative and quantitative information of the radiation. Various types of detectors and nuclear instruments are presently available and are used for different applications. This paper describes nuclear radiation, its detection and measurement and associated electronics, spectral information extraction, and advances in these fields. The paper also describes challenges in this field

  18. Improvements in AVHRR Daytime Cloud Detection Over the ARM NSA Site

    Science.gov (United States)

    Chakrapani, V.; Spangenberg, D. A.; Doelling, D. R.; Minnis, P.; Trepte, Q. Z.; Arduini, R. F.

    2001-01-01

    Clouds play an important role in the radiation budget over Arctic and Antarctic. Because of limited surface observing capabilities, it is necessary to detect clouds over large areas using satellite imagery. At low and mid-latitudes, satellite-observed visible (VIS; 0.65 micrometers) and infrared (IR; 11 micrometers) radiance data are used to derive cloud fraction, temperature, and optical depth. However, the extreme variability in the VIS surface albedo makes the detection of clouds from satellite a difficult process in polar regions. The IR data often show that the surface is nearly the same temperature or even colder than clouds, further complicating cloud detection. Also, the boundary layer can have large areas of haze, thin fog, or diamond dust that are not seen in standard satellite imagery. Other spectral radiances measured by satellite imagers provide additional information that can be used to more accurately discriminate clouds from snow and ice. Most techniques currently use a fixed reflectance or temperature threshold to decide between clouds and clear snow. Using a subjective approach, Minnis et al. (2001) found that the clear snow radiance signatures vary as a function of viewing and illumination conditions as well as snow condition. To routinely process satellite imagery over polar regions with an automated algorithm, it is necessary to account for this angular variability and the change in the background reflectance as snow melts, vegetation grows over land, and melt ponds form on pack ice. This paper documents the initial satellite-based cloud product over the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site at Barrow for use by the modeling community. Cloud amount and height are determined subjectively using an adaptation of the methodology of Minnis et al. (2001) and the radiation fields arc determined following the methods of Doelling et al. (2001) as applied to data taken during the Surface Heat and Energy Budget of the

  19. Body Height and Its Estimation Utilizing Arm Span Measurements of both Gender Adolescents from Central Region in Kosovo

    Directory of Open Access Journals (Sweden)

    Fitim Arifi

    2017-06-01

    Full Text Available This study is based on measurements of Central region Kosovar adolescents. The aim of this study was to examine the Body Height of adolescents from Central region as well relationship between arm span and Body Height in both Kosovar genders. A total measured subject participated in this research was 193 out of which (93 girls and 100 boys, females average of age is 18.15±0.35 years old (range 18-20 years and for male 18.26±0.44 years old (range 18-20 years. The anthropometric measurements were done by trained people and were taken according to the ISAK manual. Relationship between Body Height and arm span has been analyzed by the simple correlation coefficient at a 95% confidence interval. The linear regression analysis was carried out to examine extent to which arm span can reliably predict of Body Height. Statistical importance was placed at level p<0.05. As a result anthropometric measurements for both sexes showed that the average of Body Height for boys adolescents from Central region are 180.62±5.88 centimeters and have the arm span average of 181.36±7.08 centimeters, while girls from Central 166.77±4.71 centimeters tall, and have the arm span average of 167.08±5.03 centimeters. The results have shown that the arm span was estimated as a reliable indicator of Body Height assessment to the both genders adolescents from Central region of Kosovo population. This study also confirms the necessity for developing separate height models for each region in Kosovo.

  20. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  1. Evaluating the Effects of Aluminum-Containing and Non-Aluminum Containing Deodorants on Axillary Skin Toxicity During Radiation Therapy for Breast Cancer: A 3-Armed Randomized Controlled Trial

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lucy, E-mail: Lucy.lewis@curtin.edu.au [Centre for Nursing Research, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Nursing and Midwifery Curtin University, Perth (Australia); Carson, Sharron [Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); Bydder, Sean [Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, Western Australia (Australia); School of Surgery, The University of Western Australia, Crawley, Western Australia (Australia); Athifa, Mariyam [School of Nursing and Midwifery Curtin University, Perth (Australia); Williams, Anne M. [School of Nursing and Midwifery Curtin University, Perth (Australia); School of Nursing and Midwifery, Edith Cowan University, Perth, Western Australia (Australia); Bremner, Alexandra [School of Population Health, The University of Western Australia, Crawley, Western Australia (Australia)

    2014-11-15

    Purpose: Deodorant use during radiation therapy for breast cancer has been controversial as there are concerns deodorant use may exacerbate axillary skin toxicity. The present study prospectively determined the use of both aluminum-containing and non aluminum containing deodorants on axillary skin toxicity during conventionally fractionated postoperative radiation therapy for breast cancer. Methods and Materials: This 3-arm randomized controlled study was conducted at a single center, tertiary cancer hospital between March 2011 and April 2013. Participants were randomized to 1 of 2 experimental groups (aluminum-containing deodorant and soap or non–aluminum containing deodorant and soap) or a control group (soap). A total of 333 participants were randomized. Generalized estimating equations were used to estimate and compare the odds of experiencing high levels of sweating and skin toxicity in each of the deodorant groups to the odds in the control group. The study evaluated a range of endpoints including objective measurements of axilla sweating, skin toxicity, pain, itch and burning. Quality of life was assessed with a validated questionnaire. Results: Radiation characteristics were similar across all groups. Patients in the deodorant groups did not report significantly different ratings for axillary pain, itch, or burning compared with the control group. Patients in the aluminum-containing deodorant group experienced significantly less sweating than the control; the odds of their sweating being barely tolerable and frequently or always interfering with their daily activities was decreased by 85% (odds ratio, 0.15; 95% confidence interval, 0.03-0.91). Conclusions: We found no evidence that the use of either aluminum-containing or non–aluminum containing deodorant adversely effects axillary skin reaction during conventionally fractionated radiation therapy for breast cancer. Our analysis also suggests patients in the aluminum-containing deodorant arm had

  2. Evaluating the Effects of Aluminum-Containing and Non-Aluminum Containing Deodorants on Axillary Skin Toxicity During Radiation Therapy for Breast Cancer: A 3-Armed Randomized Controlled Trial

    International Nuclear Information System (INIS)

    Lewis, Lucy; Carson, Sharron; Bydder, Sean; Athifa, Mariyam; Williams, Anne M.; Bremner, Alexandra

    2014-01-01

    Purpose: Deodorant use during radiation therapy for breast cancer has been controversial as there are concerns deodorant use may exacerbate axillary skin toxicity. The present study prospectively determined the use of both aluminum-containing and non aluminum containing deodorants on axillary skin toxicity during conventionally fractionated postoperative radiation therapy for breast cancer. Methods and Materials: This 3-arm randomized controlled study was conducted at a single center, tertiary cancer hospital between March 2011 and April 2013. Participants were randomized to 1 of 2 experimental groups (aluminum-containing deodorant and soap or non–aluminum containing deodorant and soap) or a control group (soap). A total of 333 participants were randomized. Generalized estimating equations were used to estimate and compare the odds of experiencing high levels of sweating and skin toxicity in each of the deodorant groups to the odds in the control group. The study evaluated a range of endpoints including objective measurements of axilla sweating, skin toxicity, pain, itch and burning. Quality of life was assessed with a validated questionnaire. Results: Radiation characteristics were similar across all groups. Patients in the deodorant groups did not report significantly different ratings for axillary pain, itch, or burning compared with the control group. Patients in the aluminum-containing deodorant group experienced significantly less sweating than the control; the odds of their sweating being barely tolerable and frequently or always interfering with their daily activities was decreased by 85% (odds ratio, 0.15; 95% confidence interval, 0.03-0.91). Conclusions: We found no evidence that the use of either aluminum-containing or non–aluminum containing deodorant adversely effects axillary skin reaction during conventionally fractionated radiation therapy for breast cancer. Our analysis also suggests patients in the aluminum-containing deodorant arm had

  3. Radiation protection measures in the case of incidents and radiation accidents

    International Nuclear Information System (INIS)

    Herzberg, B.

    1976-01-01

    Measures to be taken in the case of radiation accidents connected with an unusually high radiation exposure to persons, the amounts of which exceed the limiting values, with depend on whether there has been an external or an internal exposure. In order to give further treatment in the case of whole-body or partial-body irradiation, it is necessary to estimate the exposure dose. In nuclear medicine the accident doses are generally low, i.e. acute radiation damage does not occur here, and immediate measures are not necessary. Therapeutic measures in the case of incorporation accidents are only necessary when the maximum amounts for the nuclide in question recommended by the ICRP has been reached or exceeded in the organism. However, decorporation measures ought to be carried out only by qualified radiation protection physicians. The type of radiation accident which occurs most frequently in nuclear medicine is radiation exposure as a result of contamination. If in the case of contamination of a person the measurement exceeds the radioactivity limit, the decontamination measures are necessary. In the present contribution, these measures for cases without injuries are described in detail. (orig./HP) [de

  4. Calculating the diffuse solar radiation in regions without solar radiation measurements

    International Nuclear Information System (INIS)

    Li, Huashan; Bu, Xianbiao; Long, Zhen; Zhao, Liang; Ma, Weibin

    2012-01-01

    Correlations for calculating diffuse solar radiation can be classified into models with global solar radiation (H-based method) and without it (Non-H method). The objective of the present study is to compare the performance of H-based and Non-H methods for calculating the diffuse solar radiation in regions without solar radiation measurements. The comparison is carried out at eight meteorological stations in China focusing on the monthly average daily diffuse solar radiation. Based on statistical error tests, the results show that the Non-H method that includes other readily available meteorological elements gives better estimates. Therefore, it can be concluded that the Non-H method is more appropriate than the H-based one for calculating the diffuse solar radiation in regions without solar radiation measurements. -- Highlights: ► Methods for calculating diffuse solar radiation in regions without solar radiation measurements are investigated. ► Diffuse solar radiation models can be classified into two groups according to global solar radiation. ► Two approaches are compared at the eight meteorological stations in China. ► The method without global solar radiation is recommended.

  5. Study on the method or reducing the operator's exposure dose from a C-Arm system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Sik; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of); Kim, Seung Ok [Dept. of Radiology, Catholic Kwangdong Universty International ST.Mary' s Hospital, Incheon (Korea, Republic of)

    2016-12-15

    In this study, C-Arm equipment is being used as we intend to verify the exposure dose on the operator by the scattering rays during the operation of the C-Arm equipment and to provide an effective method of reducing the exposure dose. Exposure dose is less than the Over Tube method utilizes the C-arm equipment Under Tube the scheme, The result showed that the exposure dose on the operator decreased with a thicker shield, and as the operator moved away from the center line. Moreover, as the research time prolongated, the exposure dose increased, and among the three affixed location of the dosimeter, the most exposure dose was measured at gonadal, then followed by chest and thyroid. However, in consideration of the relationship between the operator and the patient, the distance cannot be increased infinitely and the research time cannot be decreased infinitely in order to reduce the exposure dose. Therefore, by changing the thickness of the radiation shield, the exposure dose on the operator was able to be reduced. If you are using a C-Arm equipment discomfort during surgery because the grounds that the procedure is neglected and close to the dose of radiation shielding made can only increase. Because a separate control room cannot be used for the C-Arm equipment due to its characteristic, the exposure dose on the operator needs to be reduced by reinforcing the shield through an appropriate thickness of radiation shield devices, such as apron, etc. during a treatment.

  6. Atmospheric Radiation Measurement's Data Management Facility captures metadata and uses visualization tools to assist in routine data management.

    Science.gov (United States)

    Keck, N. N.; Macduff, M.; Martin, T.

    2017-12-01

    The Atmospheric Radiation Measurement's (ARM) Data Management Facility (DMF) plays a critical support role in processing and curating data generated by the Department of Energy's ARM Program. Data are collected near real time from hundreds of observational instruments spread out all over the globe. Data are then ingested hourly to provide time series data in NetCDF (network Common Data Format) and includes standardized metadata. Based on automated processes and a variety of user reviews the data may need to be reprocessed. Final data sets are then stored and accessed by users through the ARM Archive. Over the course of 20 years, a suite of data visualization tools have been developed to facilitate the operational processes to manage and maintain the more than 18,000 real time events, that move 1.3 TB of data each day through the various stages of the DMF's data system. This poster will present the resources and methodology used to capture metadata and the tools that assist in routine data management and discoverability.

  7. Measurement uncertainty in broadband radiofrequency radiation level measurements

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2014-01-01

    Full Text Available For the evaluation of measurement uncertainty in the measurement of broadband radio frequency radiation, in this paper we propose a new approach based on the experience of the authors of the paper with measurements of radiofrequency electric field levels conducted in residential areas of Belgrade and over 35 municipalities in Serbia. The main objective of the paper is to present practical solutions in the evaluation of broadband measurement uncertainty for the in-situ RF radiation levels. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  8. AmeriFlux Measurement Component (AMC) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Reichl, Ken [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Biraud, Sebastien C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-04-01

    An AMC system was installed at the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling photosynthetically active radiation (PAR) sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape.

  9. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  10. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  11. Ray tracing reconstruction investigation for C-arm tomosynthesis

    Science.gov (United States)

    Malalla, Nuhad A. Y.; Chen, Ying

    2016-04-01

    C-arm tomosynthesis is a three dimensional imaging technique. Both x-ray source and the detector are mounted on a C-arm wheeled structure to provide wide variety of movement around the object. In this paper, C-arm tomosynthesis was introduced to provide three dimensional information over a limited view angle (less than 180o) to reduce radiation exposure and examination time. Reconstruction algorithms based on ray tracing method such as ray tracing back projection (BP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were developed for C-arm tomosynthesis. C-arm tomosynthesis projection images of simulated spherical object were simulated with a virtual geometric configuration with a total view angle of 40 degrees. This study demonstrated the sharpness of in-plane reconstructed structure and effectiveness of removing out-of-plane blur for each reconstruction algorithms. Results showed the ability of ray tracing based reconstruction algorithms to provide three dimensional information with limited angle C-arm tomosynthesis.

  12. Validation of satellite-retrieved MBL cloud properties using DOE ARM AMF measurements at the Azores

    Science.gov (United States)

    Xi, B.; Dong, X.; Minnis, P.; Sun-Mack, S.

    2013-05-01

    Marine Boundary Layer (MBL) cloud properties derived for the Clouds and the Earth's Radiant Energy System (CERES) Project using Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data are compared with observations taken at the Atmospheric Radiation Measurement (ARM) AMF AZORES site from June 2009 through December 2010. Retrievals from ARM surface-based data were averaged over a 1-hour interval centered at the time of each satellite overpass, and the CERES-MODIS Ed4 cloud properties were averaged within a 30-km x 30-km box centered on the ARM AZORES site. Two datasets were analyzed: all of the single-layered unbroken decks (SL) and those cases without temperature inversions. The CERES-MODIS cloud top/base heights were determined from cloud top/base temperature by using a lapse rate method normalized to the 24-h mean surface air temperature. The preliminary results show: for all SL MBL at daytime, they are, on average, 0.148 km (cloud top) and 0.087 km (cloud base) higher than the ARM radar-lidar observed cloud top and base, respectively. At nighttime, they are 0.446 km (cloud top) and 0.334 km (cloud base). For those cases without temperature inversions, the comparisons are close to their SL counterparts. For cloud temperatures, the MODIS-derived cloud-top and -base temperatures are 1.6 K lower and 0.4 K higher than the surface values with correlations of 0.92 during daytime. At nighttime, the differences are slightly larger and correlations are lower than daytime comparisons. Variations in the height difference are mainly caused by uncertainties in the surface air temperatures and lapse rates. Based on a total of 61 daytime and 87 nighttime samples (ALL SL cases), the temperature inversion layers occur about 72% during daytime and 83% during nighttime. The difference of surface-observed lapse rate and the satellite derived lapse rate can be 1.6 K/km for daytime and 3.3K/km for nighttime. From these lapse rates, we can further analyze the surface

  13. Virtual Reality Aided Positioning of Mobile C-Arms for Image-Guided Surgery

    Directory of Open Access Journals (Sweden)

    Zhenzhou Shao

    2014-06-01

    Full Text Available For the image-guided surgery, the positioning of mobile C-arms is a key technique to take X-ray images in a desired pose for the confirmation of current surgical outcome. Unfortunately, surgeons and patient often suffer the radiation exposure due to the repeated imaging when the X-ray image is of poor quality or not captured at a good projection view. In this paper, a virtual reality (VR aided positioning method for the mobile C-arm is proposed by the alignment of 3D surface model of region of interest and preoperative anatomy, so that a reference pose of the mobile C-arm with respect to the inside anatomy can be figured out from outside view. It allows a one-time imaging from the outside view to greatly reduce the additional radiation exposure. To control the mobile C-arm to the desired pose, the mobile C-arm is modeled as a robotic arm with a movable base. Experiments were conducted to evaluate the accuracy of appearance model and precision of mobile C-arm positioning. The appearance model was reconstructed with the average error of 2.16 mm. One-time imaging of mobile C-arm was achieved, and new modeling of mobile C-arm with 8 DoFs enlarges the working space in the operating room.

  14. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  15. Effects of age, sex and arm on the precision of arm position sense—left-arm superiority in healthy right-handers

    OpenAIRE

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally th...

  16. Extended wavelength anisotropy resolved multidimensional emission spectroscopy (ARMES) measurements: better filters, validation standards, and Rayleigh scatter removal methods

    Science.gov (United States)

    Casamayou-Boucau, Yannick; Ryder, Alan G.

    2017-09-01

    Anisotropy resolved multidimensional emission spectroscopy (ARMES) provides valuable insights into multi-fluorophore proteins (Groza et al 2015 Anal. Chim. Acta 886 133-42). Fluorescence anisotropy adds to the multidimensional fluorescence dataset information about the physical size of the fluorophores and/or the rigidity of the surrounding micro-environment. The first ARMES studies used standard thin film polarizers (TFP) that had negligible transmission between 250 and 290 nm, preventing accurate measurement of intrinsic protein fluorescence from tyrosine and tryptophan. Replacing TFP with pairs of broadband wire grid polarizers enabled standard fluorescence spectrometers to accurately measure anisotropies between 250 and 300 nm, which was validated with solutions of perylene in the UV and Erythrosin B and Phloxine B in the visible. In all cases, anisotropies were accurate to better than ±1% when compared to literature measurements made with Glan Thompson or TFP polarizers. Better dual wire grid polarizer UV transmittance and the use of excitation-emission matrix measurements for ARMES required complete Rayleigh scatter elimination. This was achieved by chemometric modelling rather than classical interpolation, which enabled the acquisition of pure anisotropy patterns over wider spectral ranges. In combination, these three improvements permit the accurate implementation of ARMES for studying intrinsic protein fluorescence.

  17. High Spectral Resolution Infrared and Raman Lidar Observations for the ARM Program: Clear and Cloudy Sky Applications

    Energy Technology Data Exchange (ETDEWEB)

    Revercomb, Henry; Tobin, David; Knuteson, Robert; Borg, Lori; Moy, Leslie

    2009-06-17

    This grant began with the development of the Atmospheric Emitted Radiance Interferometer (AERI) for ARM. The AERI has provided highly accurate and reliable observations of downwelling spectral radiance (Knuteson et al. 2004a, 2004b) for application to radiative transfer, remote sensing of boundary layer temperature and water vapor, and cloud characterization. One of the major contributions of the ARM program has been its success in improving radiation calculation capabilities for models and remote sensing that evolved from the multi-year, clear-sky spectral radiance comparisons between AERI radiances and line-by-line calculations (Turner et al. 2004). This effort also spurred us to play a central role in improving the accuracy of water vapor measurements, again helping ARM lead the way in the community (Turner et al. 2003a, Revercomb et al. 2003). In order to add high-altitude downlooking AERI-like observations over the ARM sites, we began the development of an airborne AERI instrument that has become known as the Scanning High-resolution Interferometer Sounder (Scanning-HIS). This instrument has become an integral part of the ARM Unmanned Aerospace Vehicle (ARM-UAV) program. It provides both a cross-track mapping view of the earth and an uplooking view from the 12-15 km altitude of the Scaled Composites Proteus aircraft when flown over the ARM sites for IOPs. It has successfully participated in the first two legs of the “grand tour” of the ARM sites (SGP and NSA), resulting in a very good comparison with AIRS observations in 2002 and in an especially interesting data set from the arctic during the Mixed-Phase Cloud Experiment (M-PACE) in 2004.

  18. Methodology for the assessment of measuring uncertainties of articulated arm coordinate measuring machines

    International Nuclear Information System (INIS)

    Romdhani, Fekria; Hennebelle, François; Ge, Min; Juillion, Patrick; Fontaine, Jean François; Coquet, Richard

    2014-01-01

    Articulated Arm Coordinate Measuring Machines (AACMMs) have gradually evolved and are increasingly used in mechanical industry. At present, measurement uncertainties relating to the use of these devices are not yet well quantified. The work carried out consists of determining the measurement uncertainties of a mechanical part by an AACMM. The studies aiming to develop a model of measurement uncertainty are based on the Monte Carlo method developed in Supplement 1 of the Guide to Expression of Uncertainty in Measurement [1] but also identifying and characterizing the main sources of uncertainty. A multi-level Monte Carlo approach principle has been developed which allows for characterizing the possible evolution of the AACMM during the measurement and quantifying in a second level the uncertainty on the considered measurand. The first Monte Carlo level is the most complex and is thus divided into three sub-levels, namely characterization on the positioning error of a point, estimation of calibration errors and evaluation of fluctuations of the ‘localization point’. The global method is thus presented and results of the first sub-level are particularly developed. The main sources of uncertainty, including AACMM deformations, are exposed. (paper)

  19. Radiation exposure during ureteroscopy

    International Nuclear Information System (INIS)

    Bagley, D.H.; Cubler-Goodman, A.

    1990-01-01

    Use of fluoroscopy during ureteroscopy increases the risk of radiation exposure to the urologist and patient. Radiation entrance dosages were measured at skin level in 37 patients, and at the neck, trunk and finger of the urologist, and neck and trunk of the circulating nurse. Radiation exposure time was measured in 79 patients, and was related to the purpose of the procedure and the type of ureteroscope used, whether rigid or flexible. Exposure could be minimized by decreasing the fluoroscopy time. A portable C-arm fluoroscopy unit with electronic imaging and last image hold mode should be used to minimize exposure time. Lead aprons and thyroid shields should be used by the urologist and other personnel in the endoscopy room

  20. Measurement and detection of radiation

    CERN Document Server

    Tsoulfanidis, Nicholas

    2011-01-01

    This is an update of the standard textbook for the field of radiation measurement. It includes illustrative examples and new problems. The research and applications of nuclear instrumentation have grown substantially since publication of the previous editions. With the miniaturization of equipment, increased speed of electronic components, and more sophisticated software, radiation detection systems are now more productively used in many disciplines, including nuclear nonproliferation, homeland security, and nuclear medicine. Continuing in the tradition of its bestselling predecessors, "Measurement and Detection of Radiation, Third Edition" illustrates the fundamentals of nuclear interactions and radiation detection with a multitude of examples and problems. It offers a clearly written, accessible introduction to nuclear instrumentation concepts. The following are new to the third edition: a new chapter on the latest applications of radiation detection, covering nuclear medicine, dosimetry, health physics, no...

  1. Information booklet on personal protective equipment: arm and hand protection

    International Nuclear Information System (INIS)

    1992-01-01

    Fire, heat, cold, electro-magnetic and ionising radiation, electricity, chemicals, impacts, cuts, abrasion, etc. are the common hazards for arms and hands at work. The gloves chosen for protection of the arm and hand should cover those parts adequately and the material of the gloves should be capable of offering protection against the specific hazard involved. Criteria for choosing arm and hand protection equipment will be based on their shape and part of the arm and hand protected. Guide lines for choosing such personal protection equipment for nuclear facilities are given. (M.K.V.). 3 annexures, 1 appendix

  2. The ARM Cloud Radar Simulator for Global Climate Models: Bridging Field Data and Climate Models

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yuying [Lawrence Livermore National Laboratory, Livermore, California; Xie, Shaocheng [Lawrence Livermore National Laboratory, Livermore, California; Klein, Stephen A. [Lawrence Livermore National Laboratory, Livermore, California; Marchand, Roger [University of Washington, Seattle, Washington; Kollias, Pavlos [Stony Brook University, Stony Brook, New York; Clothiaux, Eugene E. [The Pennsylvania State University, University Park, Pennsylvania; Lin, Wuyin [Brookhaven National Laboratory, Upton, New York; Johnson, Karen [Brookhaven National Laboratory, Upton, New York; Swales, Dustin [CIRES and NOAA/Earth System Research Laboratory, Boulder, Colorado; Bodas-Salcedo, Alejandro [Met Office Hadley Centre, Exeter, United Kingdom; Tang, Shuaiqi [Lawrence Livermore National Laboratory, Livermore, California; Haynes, John M. [Cooperative Institute for Research in the Atmosphere/Colorado State University, Fort Collins, Colorado; Collis, Scott [Argonne National Laboratory, Argonne, Illinois; Jensen, Michael [Brookhaven National Laboratory, Upton, New York; Bharadwaj, Nitin [Pacific Northwest National Laboratory, Richland, Washington; Hardin, Joseph [Pacific Northwest National Laboratory, Richland, Washington; Isom, Bradley [Pacific Northwest National Laboratory, Richland, Washington

    2018-01-01

    Clouds play an important role in Earth’s radiation budget and hydrological cycle. However, current global climate models (GCMs) have had difficulties in accurately simulating clouds and precipitation. To improve the representation of clouds in climate models, it is crucial to identify where simulated clouds differ from real world observations of them. This can be difficult, since significant differences exist between how a climate model represents clouds and what instruments observe, both in terms of spatial scale and the properties of the hydrometeors which are either modeled or observed. To address these issues and minimize impacts of instrument limitations, the concept of instrument “simulators”, which convert model variables into pseudo-instrument observations, has evolved with the goal to improve and to facilitate the comparison of modeled clouds with observations. Many simulators have (and continue to be developed) for a variety of instruments and purposes. A community satellite simulator package, the Cloud Feedback Model Intercomparison Project (CFMIP) Observation Simulator Package (COSP; Bodas-Salcedo et al. 2011), contains several independent satellite simulators and is being widely used in the global climate modeling community to exploit satellite observations for model cloud evaluation (e.g., Klein et al. 2013; Zhang et al. 2010). This article introduces a ground-based cloud radar simulator developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program for comparing climate model clouds with ARM observations from its vertically pointing 35-GHz radars. As compared to CloudSat radar observations, ARM radar measurements occur with higher temporal resolution and finer vertical resolution. This enables users to investigate more fully the detailed vertical structures within clouds, resolve thin clouds, and quantify the diurnal variability of clouds. Particularly, ARM radars are sensitive to low-level clouds, which are

  3. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  4. Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Werncke, Thomas, E-mail: Werncke.Thomas@mh-hannover.de [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Sonnow, Lena; Meyer, Bernhard C. [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany); Lüpke, Matthias [University of Veterinary Medicine Hannover, Institute for General Radiology and Medical Physics, Bischofsholer Damm 15, 30173 Hannover (Germany); Hinrichs, Jan; Wacker, Frank K.; Falck, Christian von [Institute of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover (Germany)

    2017-04-15

    Objective: Objective of this phantom and cadaveric study was to compare the effective radiation dose (ED) and image quality (IQ) between C-arm computed tomography (CACT) using an ultra-high resolution 1 × 1 binning with a standard 16-slice CT (MDCT) arthrography of the wrist. Methods: ED was determined with thermoluminescence dosimetry using an anthropomorphic phantom and different patient positions. Imaging was conducted in 10 human cadaveric wrists after tri-compartmental injection of diluted iodinated contrast material and a wire phantom. IQ of MDCT was compared with CACT reconstructed with a soft (CACT1) and sharp (CACT2) kernel. High and low contrast resolution was determined. Three radiologists assessed IQ of wrist structures and occurrence of image artifacts using a 5-point Likert scale. Results: ED of MDCT was comparable to standard CACT (4.3 μSv/3.7 μSv). High contrast resolution was best for CACT2, decreased to CACT1 and MDCT. Low contrast resolution increased between CACT2 and MDCT (P < 0.001). IQ was best for CACT2 (1.3 ± 0.5), decreased to CACT1 (1.9 ± 0.6) and MDCT (3.5 ± 0.6). Non-compromising artifacts were only reported for CACT. Conclusions: The results of this phantom and cadaveric study indicate that ultra-high resolution C-Arm CT arthrography of the wrist bears the potential to outperform MDCT arthrography in terms of image quality and workflow at the cost of mildly increasing image artifacts while radiation dose to the patient is comparably low for both, MDCT and C-Arm CT.

  5. Body Height and its Estimation Utilizing Arm Span Measurements in Male Adolescents from Southern Region in Montenegro

    Directory of Open Access Journals (Sweden)

    Rajko Milašinović

    2016-06-01

    Full Text Available The purpose of this study was to examine the body height in Montenegrin male adolescents from southern region as well as the relationship between arm span as an alternative to estimating the body height, which would vary from region to region in Montenegro. Our investigation analyses 87 male adolescents from the southern region in Montenegro. The anthropometric measurements were taken according to the protocol of the International Society for the Advancement of Kinanthropometry (ISAK. Means and standard deviations regarding the anthropometric measurements were obtained. The relationships between body height and arm span were determined using simple correlation coefficients and their 95% confidence interval. Then a linear regression analysis was performed to examine the extent to which the arm span can reliably predict body height. The results displayed that male Southern-Montenegrins are 182.53±7.53 cm tall and have an arm span of 184.55±9.03 cm. Compared to other studies, the results of this study have shown that this gender made Southern- Montenegrins the tall population, taller than most of nation around the Europe. On the other hand, expectably, the arm span reliably predicts body height in this gender. However, the estimation equations which have been obtained in Southern-Montenegrins are, different alike in general population, since arm span was closer to body heights (2.03±1.50 cm, more than in general population. Hence, this study also confirms the necessity for developing separate height models for each region in Montenegro.

  6. BODY HEIGHT AND ITS ESTIMATION UTILIZING ARM SPAN MEASUREMENTS IN MALE ADOLESCENTS FROM CENTRAL REGION IN MONTENEGRO

    Directory of Open Access Journals (Sweden)

    Dobrislav Vujović

    2015-05-01

    Full Text Available Anthropologists recognized the tallness of nations in the Dinaric Alps long time ago (Popovic et al, 2013. As the modern Montenegrins fall partly into the Dinaric racial classification (Bjelica et al., 2012, the purpose of this study was to examine the body height in Montenegrin male adolescents from central region as well as the relationship between arm span as an alternative to estimating the body height, which would vary from region to region in Montenegro. Method: Our investigation analyses 548 male adolescents from the central region in Montenegro. The anthropometric measurements were taken according to the protocol of the International Society for the Advancement of Kinanthropometry (ISAK. Means and standard deviations regarding the anthropometric measurements were obtained. A comparison of means of body heights and arm spans within this gender group were carried out using a t-test. The relationships between body height and arm span were determined using simple correlation coefficients and their 95% confidence interval. Then a linear regression analysis was performed to examine the extent to which the arm span can reliably predict body height. Results: The results displayed that male Central-Montenegrins are 183.66±6.93 cm tall and have an arm span of 184.99±8.30cm. Discussion: Compared to other studies, the results of this study have shown that this gender made Central-Macedonians the tall population, taller than general male population in Montenegro (Bjelica et al., 2012. On the other hand, expectably, the arm span reliably predicts body height in this gender. However, the estimation equations which have been obtained in Central-Montenegrins are, different alike in general population, since arm span was closer to body heights (1.33±1.37 centimetres, more than in general population (Bjelica et al., 2012. This confirms the necessity for developing separate height models for each region in Montenegro.

  7. Pressing problems of measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Fominykh, V.I.; Yudin, M.F.

    1993-01-01

    The current system for ensuring the unity of measurements in the Russian Federation and countries of the former Soviet Union ensures a high quality of dosimetric, radiometric, and spectrometric measurements in accordance with the recommendations of the Consulative Committee on Standards for Measurements of Ionizing Radiations of the International Bureau of Weights and Measures (IBWM), International Organization on Radiological Units (ICRU), International Commission on Radiological Protection (ICRP), International Organization on Legislative Metrology (IOLM), International Atomic Energy Agency (IAEA), World Health Organization (WHO), etc. Frequent collation of the national primary and secondary standards of Russia with those of IBWM and the leading national laboratories of the world facilitate mutual verification of the measurements of ionizing radiations. The scope of scientific and scientific-technical problems that can be solved by using ionizing radiations has expanded significantly in recent years. In this paper the authors consider some pressing problems of the metrology of ionizing radiations which have arisen as a result of this expansion. These include the need for unity and reliability of measurements involved in radiation protection, the measurement of low doses involving low dose rates, ensuring the unity of measurements when monitoring the radiological security of the population, the need for more uniformity on an international scale regarding the basic physical quantities and their units for characterizing radiation fields, determination of the accuracy of measurement of the radiation dose absorbed by an irradiated tissue or organ, and the development of complex standards for ionizing radiations. 5 refs., 1 tab

  8. CyARM: Haptic Sensing Device for Spatial Localization on Basis of Exploration by Arms

    Directory of Open Access Journals (Sweden)

    Junichi Akita

    2009-01-01

    Full Text Available We introduce a new type of perception aid device based on user's exploration action, which is named as CyARM (acronym of “Cyber Arm”. The user holds this device in her/his arm, the extension of the arm is controlled by tension in wires, which are attached to her/his body according to the distance to the object. This user interface has unique characteristics that give users the illusion of an imaginary arm that extends to existing objects. The implementations of CyARM and our two experiments to investigate the efficiency and effectiveness of CyARM are described. The results show that we could confirm that CyARM can be used to recognize the presence of an object in front of the user and to measure the relative distance to the object.

  9. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    The book is a complete, clear and up-to-date text that provides a basic review of instruments and methods of ionizing radiation. The text covers detailed discussion of all detector types introductory discussions of radiation sources, interactions, and counting statistics functional analysis of the electronics and pulse processing aspects of radiation detectors in instrumentation systems and consideration of shielding and background potentially vital in low-level counting. A total of 350 figures and approximately 900 references to current scientific literature is included. The book is largely intended as a textbook for a junior/senior or first-year graduate course in nuclear instrumentation and radiation measurements

  10. MEASUREMENT OF GALACTIC LOGARITHMIC SPIRAL ARM PITCH ANGLE USING TWO-DIMENSIONAL FAST FOURIER TRANSFORM DECOMPOSITION

    International Nuclear Information System (INIS)

    Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S.; Puerari, Ivânio

    2012-01-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.

  11. Measurement of Galactic Logarithmic Spiral Arm Pitch Angle Using Two-dimensional Fast Fourier Transform Decomposition

    Science.gov (United States)

    Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S.; Puerari, Ivânio

    2012-04-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.

  12. MEASUREMENT OF GALACTIC LOGARITHMIC SPIRAL ARM PITCH ANGLE USING TWO-DIMENSIONAL FAST FOURIER TRANSFORM DECOMPOSITION

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S. [Arkansas Center for Space and Planetary Sciences, 202 Field House, University of Arkansas, Fayetteville, AR 72701 (United States); Puerari, Ivanio [Instituto Nacional de Astrofisica, Optica y Electronica, Calle Luis Enrique Erro 1, 72840 Santa Maria Tonantzintla, Puebla (Mexico)

    2012-04-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quantitative way to measure this morphological feature. This will allow comparison of spiral galaxy pitch angle to other galactic parameters and test spiral arm genesis theories. In this work, we detail our image processing and analysis of spiral galaxy images and discuss the robustness of our analysis techniques.

  13. The Great Plains low-level jet (LLJ) during the atmospheric radiation measurement (ARM) intensive observation period (IOP)-4 and simulations of land use pattern effect on the LLJ

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y.; Raman, S. [North Carolina State Univ., Raleigh, NC (United States)

    1996-04-01

    The Great Plains low-level jet (LLJ) is an important element of the low-level atmospheric circulation. It transports water vapor from the Gulf of Mexico, which in turn affects the development of weather over the Great Plains of the central United States. The LLJ is generally recognized as a complex response of the atmospheric boundary layer to the diurnal cycle of thermal forcing. Early studies have attributed the Great Plains LLJ to the diurnal oscillations of frictional effect, buoyancy over sloping terrain, and the blocking effects of the Rocky Mountains. Recent investigations show that the speed of the LLJ is also affected by the soil type and soil moisture. Some studies also suggest that synoptic patterns may play an important role in the development of the LLJ. Land surface heterogeneties significantly affect mesoscale circulations by generating strong contrasts in surface thermal fluxes. Thus one would expect that the land use pattern should have effects on the LLJ`s development and structure. In this study, we try to determine the relative roles of the synoptic forcing, planetary boundary layers (PBL) processes, and the land use pattern in the formation of the LLJ using the observations from the Atmospheric Radiation Measurement (ARM) Intensive Operation Period (IOP)-4 and numerical sensitivity tests.

  14. A long-term study of aerosol–cloud interactions and their radiative effect at the Southern Great Plains using ground-based measurements

    Directory of Open Access Journals (Sweden)

    E. T. Sena

    2016-09-01

    Full Text Available Empirical estimates of the microphysical response of cloud droplet size distribution to aerosol perturbations are commonly used to constrain aerosol–cloud interactions in climate models. Instead of empirical microphysical estimates, here macroscopic variables are analyzed to address the influence of aerosol particles and meteorological descriptors on instantaneous cloud albedo and the radiative effect of shallow liquid water clouds. Long-term ground-based measurements from the Atmospheric Radiation Measurement (ARM program over the Southern Great Plains are used. A broad statistical analysis was performed on 14 years of coincident measurements of low clouds, aerosol, and meteorological properties. Two cases representing conflicting results regarding the relationship between the aerosol and the cloud radiative effect were selected and studied in greater detail. Microphysical estimates are shown to be very uncertain and to depend strongly on the methodology, retrieval technique and averaging scale. For this continental site, the results indicate that the influence of the aerosol on the shallow cloud radiative effect and albedo is weak and that macroscopic cloud properties and dynamics play a much larger role in determining the instantaneous cloud radiative effect compared to microphysical effects. On a daily basis, aerosol shows no correlation with cloud radiative properties (correlation = −0.01 ± 0.03, whereas the liquid water path shows a clear signal (correlation = 0.56 ± 0.02.

  15. Arms control and disarmament

    International Nuclear Information System (INIS)

    Acton, P.

    1992-01-01

    Article VI of the Non-Proliferation Treaty commits each party to work towards nuclear disarmament and to negotiations to stop the nuclear arms race. All parties to the Treaty are included and a wide range of arms control and disarmament issues are covered. However the main focus at Treaty review conferences has been on nuclear disarmament by the nuclear weapon states which are party to the Treaty. This has led to bilateral United States - Soviet Union negotiations resulting in the Intermediate-range Nuclear Forces Treaty in December 1987 and the Strategic Arms Reduction Treaty (START) in July followed by unilateral arms control measures in September and October 1991. (UK)

  16. Isolated effects of peripheral arm and central body cooling on arm performance.

    Science.gov (United States)

    Giesbrecht, G G; Wu, M P; White, M D; Johnston, C E; Bristow, G K

    1995-10-01

    Whole body cooling impairs manual arm performance. The independent contributions of local (peripheral) and/or whole body (central) cooling are not known. Therefore, a protocol was developed in which the arm and the rest of the body could be independently cooled. Biceps temperature (Tmus), at a depth of 20 mm, and esophageal temperature (Tes) were measured. Six subjects were immersed to the clavicles in a tank (body tank) of water under 3 conditions: 1) cold body-cold arm (CB-CA); 2) warm body-cold arm (WB-CA); and 3) cold body-warm arm (CB-WA). In the latter two conditions, subjects placed their dominant arm in a separate (arm) tank. Water temperature (Tw) in each tank was independently controlled. In conditions requiring cold body and/or cold arm, Tw in the appropriate tanks was 8 degrees C. In conditions requiring warm body and/or warm arm, Tw in the appropriate tanks was adjusted between 29 and 38 degrees C to maintain body/arm temperature at baseline values. A battery of 6 tests, requiring fine or gross motor movements, were performed immediately before immersion and after 15, 45, and 70 minutes of immersion. In CB-CA, Tes decreased from an average of 37.2 to 35.6 degrees C and Tmus decreased from 34.6 to 22.0 degrees C. In WB-CA, Tmus decreased to 18.1 degrees C (Tes = 37.1 degrees C), and in CB-WA, Tes decreased to 35.8 degrees C (Tmus = 34.5 degrees C). By the end of immersion, there were significant decrements (43-85%) in the performance of all tests in CB-CA and WB-CA (p body and/or the arm elicits large decrements in finger, hand and arm performance. The decrements are due almost entirely to the local effects of arm tissue cooling.

  17. Evaluation of the dose distribution of dynamic conical conformal therapy using a C-arm mounted accelerator

    International Nuclear Information System (INIS)

    Nakagawa, Keiichi; Aoki, Yukimasa; Ohtomo, Kuni

    2001-01-01

    Conformal radiation therapy, which is widely utilized in Japan as a standard, highly precise technique has limited advantage in dose confinement because of its coplanar beam entry. An improved form of conformal therapy is delivered by a linac mounted on a C-arm rotatable gantry. The linac head was designed to move along the C-arm with a maximum angle of 60 degrees. Simultaneous rotation of the gantry creates a Dynamic Conical irradiation technique. Dynamic Conical Conformal Therapy (Dyconic Therapy) was developed by combining the technique with continuous MLC motion based on beam's eye views of the target volume. Dose distributions were measured in a phantom using film densitometry and compared with conventional conformal radiation therapy. The measurements showed that the dose distribution conformed to the target shape identified by CT. In addition, the dose distribution for a cancer patient was evaluated through the use of DVHs generated by a treatment planning system. These measurements showed that the dose distribution along the patient's long axis conformed to the shape of the target volume. DVH analysis, however, did not indicate superiority of the present technique over the conventional technique. Angulation of the C-arm gantry allowed the primary beam to strike a larger area of the therapy room. This necessitated adding shielding to the walls and ceiling of the treatment room. It was confirmed that the leakage radiation was reduced to a negligible level by adding an iron plate 20 cm thick to several places on the side walls, by adding an iron plate 9 cm thick to several places on the ceiling, and by increasing the thickness of the concrete ceiling from 70 to 140 cm. The possible usefulness of Dyconic Therapy was confirmed. (author)

  18. Characteristics and correlation of various radiation measuring methods in spatial radiation measurement

    International Nuclear Information System (INIS)

    Yoneda, Kazuhiro; Tonouchi, Shigemasa

    1992-01-01

    When the survey of the state of natural radiation distribution was carried out, for the purpose of examining the useful measuring method, the comparison of the γ-ray dose rate calculated from survey meter method, in-situ measuring method and the measuring method by sampling soil was carried out. Between the in-situ measuring method and the survey meter method, the correlation Y=0.986X+5.73, r=0.903, n=18, P<0.01 was obtained, and the high correlation having the inclination of nearly 1 was shown. Between the survey meter method and the measuring method by sampling soil, the correlation Y=1.297X-10.30, r=0.966, n=20 P<0.01 was obtained, and the high correlation was shown, but as for the dose rate contribution, the disparities of 36% in U series, 6% in Th series and 20% in K-40 were observed. For the survey of the state of natural radiation distribution, the method of using in combination the survey meter method and the in-situ measuring method or the measuring method by sampling soil is suitable. (author)

  19. Comparison of Marine Boundary Layer Cloud Properties from CERES-MODIS Edition 4 and DOE ARM AMF Measurements at the Azores

    Science.gov (United States)

    Xi, Baike; Dong, Xiquan; Minnis, Patrick; Sun-Mack, Sunny

    2014-01-01

    Marine boundary layer (MBL) cloud properties derived from the NASA Clouds and the Earth's Radiant Energy System (CERES) project using Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) data are compared with observations taken at the Department of Energy Atmospheric Radiation Measurement (ARM) Mobile Facility at the Azores (AMF-Azores) site from June 2009 through December 2010. Cloud properties derived from ARM ground-based observations were averaged over a 1 h interval centered at the satellite overpass time, while the CERES-MODIS (CM) results were averaged within a 30 km×30 km grid box centered over the Azores site. A total of 63 daytime and 92 nighttime single-layered overcast MBL cloud cases were selected from 19 months of ARM radar-lidar and satellite observations. The CM cloud top/base heights (Htop/Hbase) were determined from cloud top/base temperatures (Ttop/Tbase) using a regional boundary layer lapse rate method. For daytime comparisons, the CM-derived Htop (Hbase), on average, is 0.063 km (0.068 km) higher (lower) than its ARM radar-lidar-observed counterpart, and the CM-derived Ttop and Tbase are 0.9 K less and 2.5 K greater than the surface values with high correlations (R(sup 2) = 0.82 and 0.84, respectively). In general, the cloud top comparisons agree better than the cloud base comparisons, because the CM cloud base temperatures and heights are secondary products determined from cloud top temperatures and heights. No significant day-night difference was found in the analyses. The comparisons of MBL cloud microphysical properties reveal that when averaged over a 30 km× 30 km area, the CM-retrieved cloud droplet effective radius (re) at 3.7 micrometers is 1.3 micrometers larger than that from the ARM retrievals (12.8 micrometers), while the CM-retrieved cloud liquid water path (LWP) is 13.5 gm( exp -2) less than its ARM counterpart (114.2 gm( exp-2) due to its small optical depth (9.6 versus 13.7). The differences are reduced by 50

  20. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Science.gov (United States)

    Hu, Weitong; Li, Juxiang; Su, Hai; Wang, Jiwei; Xu, Jinsong; Liu, Yanna; Huang, Ming; Cheng, Xiaoshu

    2014-01-01

    To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r) induced by one arm ischemia correlates with flow-mediated dilatation (FMD). Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D) was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives). Following baseline diameter (D0) and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD) was calculated as the percentage increase of artery diameter (ΔD/D0). The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r). At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, Parm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  1. Does "hidden undercuffing" occur among obese patients? Effect of arm sizes and other predictors of the difference between wrist and upper arm blood pressures.

    Science.gov (United States)

    Doshi, Hardik; Weder, Alan B; Bard, Robert L; Brook, Robert D

    2010-02-01

    Arm size can affect the accuracy of blood pressure (BP) measurement, and "undercuffing" of large upper arms is likely to be a growing problem. Therefore, the authors investigated the relationship between upper arm and wrist readings. Upper arm and wrist circumferences and BP were measured in 261 consecutive patients. Upper arm auscultation and wrist BP was measured in triplicate, rotating measurements every 30 seconds between sites. Upper arm BP was 131.9+/-20.6/71.6+/-12.6 mm Hg in an obese population (body mass index, 30.6+/-6.6 kg/m(2)) with mean upper arm size of 30.7+/-5.1 cm. Wrist BP was higher (2.6+/-9.2 mm Hg and 4.9+/-6.6 mm Hg, respectively, PBlood Pressure (JNC 7) strata (kappa value=0.27-0.71), and the difference was >or=5 mm Hg in 72% of the patients. The authors conclude that there was poor concordance between arm and wrist BP measurement and found no evidence that "hidden undercuffing" was associated with obesity; therefore, they do not support routine use of wrist BP measurements.

  2. Quality assurance in field radiation measurements

    International Nuclear Information System (INIS)

    Howell, W.P.

    1985-01-01

    In most cases, an ion chamber radiation measuring instrument is calibrated in a uniform gamma radiation field. This results in a uniform ionization field throughout the ion chamber. Measurement conditions encountered in the field often produce non-uniform ionization fields within the ion chamber, making determination of true dose rates to personnel difficult and prone to error. Extensive studies performed at Hanford have provided appropriate correction factors for use with one type of ion chamber instrument, the CP. Suitable corrections are available for the following distinct measurement circumstances: (1) contact measurements on large beta and gamma sources, (2) contact measurements on small beta and gamma sources, (3) contact measurements on small-diameter cylinders, (4) measurements in small gamma beams, and (5) measurements at a distance from large beta sources. Recommendations are made for the implementation of these correction factors, in the interest of improved quality assurance in field radiation measurements. 12 references, 10 figures

  3. Patient characteristics and factors associated with inter-arm difference of blood pressure measurements in a general population in Ohasama, Japan.

    Science.gov (United States)

    Kimura, Atsushi; Hashimoto, Junichiro; Watabe, Daisuke; Takahashi, Hisaki; Ohkubo, Takayoshi; Kikuya, Masahiro; Imai, Yutaka

    2004-12-01

    To assess whether there is a natural difference in blood pressure (BP) measurements between the right and left arms, and to identify what factors are associated with this difference in a general population. The study subjects were 1090 individuals who participated in a medical check-up in Ohasama, Japan. The BP was measured simultaneously in both arms, using an automated device. The inter-arm BP difference was expressed as the relative difference [right-arm BP (R) minus left-arm BP (L): R - L] and the absolute difference (|R - L|). The relationship between inter-arm difference and various factors was analyzed using univariate analysis. The characteristics of subjects in whom the absolute systolic BP (SBP) difference was greater than 10 mmHg were analyzed using multivariate logistic analysis. The relative differences in SBP and diastolic BP (DBP) were -0.6 +/- 6.6 (mean +/- SD) and 1.1 +/- 4.7 mmHg, while the absolute differences were 4.9 +/- 4.4 and 3.7 +/- 3.0 mmHg. The absolute SBP difference was found to correlate significantly with age, body mass index, ankle-brachial index (ABI), and hypertension. Subjects with hypertension, hypercholesterolemia, obesity, elevated hemoglobin A1c (HbA1c) and low ABI had a significant and independent increase in the risk of an absolute SBP difference greater than 10 mmHg. The results suggest that there is considerable difference in the measured BP in the right and left arms and that large differences in the absolute SBP are associated with risk factors for arteriosclerosis such as hypertension, hypercholesterolemia, obesity, metabolic abnormalities and low ABI.

  4. Application of microprocessors to radiation protection measurements

    International Nuclear Information System (INIS)

    Zappe, D.; Meldes, C.

    1982-01-01

    In radiation protection measurements signals from radiation detectors or dosemeters have to be transformed into quantities relevant to radiation protection. In most cases this can only be done by taking into account various parameters (e.g. the quality factor). Moreover, the characteristics of the statistical laws of nuclear radiation emission have to be considered. These problems can properly be solved by microprocessors. After reviewing the main properties of microprocessors, some typical examples of applying them to problems of radiation protection measurement are given. (author)

  5. BODY HEIGHT AND ITS ESTIMATION UTILIZING ARM SPAN MEASUREMENTS IN FEMALE ADOLESCENTS FROM CENTRAL REGION IN MONTENEGRO

    Directory of Open Access Journals (Sweden)

    Marija Bubanja

    2015-05-01

    Full Text Available Anthropologists recognized the tallness of nations in the Dinaric Alps long time ago (Popovic et al, 2013. As the modern Montenegrins fall partly into the Dinaric racial classification (Bjelica et al., 2012, the purpose of this study was to examine the body height in Montenegrin female adolescents from central region as well as the relationship between arm span as an alternative to estimating the body height, which would vary from region to region in Montenegro. Method: Our investigation analyses 593 female adolescents from the central region in Montenegro. The anthropometric measurements were taken according to the protocol of the International Society for the Advancement of Kinanthropometry (ISAK. Means and standard deviations regarding the anthropometric measurements were obtained. A comparison of means of body heights and arm spans within this gender group were carried out using a t-test. The relationships between body height and arm span were determined using simple correlation coefficients and their 95% confidence interval. Then a linear regression analysis was performed to examine the extent to which the arm span can reliably predict body height. Results: The results displayed that female Central-Montenegrins are 169.24±11.61cm tall and have an arm span of 168.03±10.34cm. Discussion: Compared to other studies, the results of this study have shown that this gender made Central-Macedonians the tall population, taller than general female population in Montenegro (Bjelica et al., 2012. On the other hand, expectably, the arm span reliably predicts body height in this gender. However, the estimation equations which have been obtained in Central-Montenegrins are, different alike in general population, since arm span was shorter than the body heights (1.21±1.27 centimetres, much more than in general population (Bjelica et al., 2012. This confirms the necessity for developing separate height models for each region in Montenegro.

  6. Radiation budget measurement/model interface

    Science.gov (United States)

    Vonderhaar, T. H.; Ciesielski, P.; Randel, D.; Stevens, D.

    1983-01-01

    This final report includes research results from the period February, 1981 through November, 1982. Two new results combine to form the final portion of this work. They are the work by Hanna (1982) and Stevens to successfully test and demonstrate a low-order spectral climate model and the work by Ciesielski et al. (1983) to combine and test the new radiation budget results from NIMBUS-7 with earlier satellite measurements. Together, the two related activities set the stage for future research on radiation budget measurement/model interfacing. Such combination of results will lead to new applications of satellite data to climate problems. The objectives of this research under the present contract are therefore satisfied. Additional research reported herein includes the compilation and documentation of the radiation budget data set a Colorado State University and the definition of climate-related experiments suggested after lengthy analysis of the satellite radiation budget experiments.

  7. Measurement of radiative decay of the resonances J/phi and phi' in tensor mesons

    International Nuclear Information System (INIS)

    Fues, W.

    1981-01-01

    At decays of the vector mesons J/psi(3100) and psi'(3685) into the final states γπ + π - and γK + K - radiative decays into the isoscalar tensor mesons f(1270) and f'(15) were looked for: J/psi → γf → γπ + π - , J/psi → γ f' → γK + K - , psi' → γf → γπ + π - , psi' → γf' → γK + K - . The measurements were performed using the double arm spectrometer DASP at the e + e - storage ring DORIS at DESY in Hamburg. The decay J/psi → γg could be observed, the measured branching ratio is GAMMA (J/psi → γf)/γ(J/psi → all) = (1.18 +- 0.28) x 10 -3 . For the other decays upper limits for the branching ratios are derived. The results are consistent with a description in the framework of quantum chromodynamics, where these radiative decays result by annihilation at the charmed quark and its antiquark into two gluons and a real photon, and the gluon system goes over into a tensor meson. In the studied mass spectra at the meson pairs from the radiative decays of J/psi and psi' no indication for a gluon bound state could be found. For the process psi' → γ 'etasub(c)(2980)' → γπ + π - or γK + K - an upper limit for the branching ratio is indicated. (HSI)

  8. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  9. Phase-dependent organization of postural adjustments associated with arm movements while walking.

    Science.gov (United States)

    Nashner, L M; Forssberg, H

    1986-06-01

    This study examines the interactions between anteroposterior postural responses and the control of walking in human subjects. In the experimental paradigm, subjects walked upon a treadmill, gripping a rigid handle with one hand. Postural responses at different phases of stepping were elicited by rapid arm pulls or pushes against the handle. During arm movements, EMG's recorded the activity of representative arm, ankle, and thigh segment muscles. Strain gauges in the handle measured the force of the arm movement. A Selspot II system measured kinematics of the stepping movements. The duration of support and swing phases were marked by heel and toe switches in the soles of the subjects' shoes. In the first experiment, subjects were instructed to pull on the handle at their own pace. In these trials all subjects preferred to initiate pulls near heel strikes. Next, when instructed to pull as rapidly as possible in response to tone stimuli, reaction times were similar for all phases of the step cycle. Leg muscle responses associated with arm pulls and pushes, referred to as "postural activations," were directionally specific and preceded arm muscle activity. The temporal order and spatial distribution of postural activations in the muscles of the support leg were similar when arm pull movements occurred while the subject was standing in place and after heel strike while walking. Activations began in the ankle and radiated proximally to the thigh and then the arm. Activations of swing leg muscles were also directionally specific and involved flexion and forward or backward thrust of the limb. When arm movements were initiated during transitions from support by one leg to the other, patterns of postural activations were altered. Alterations usually occurred 10-20 ms before hell strikes and involved changes in the timing and sometimes the spatial structure of postural activations. Postural activation patterns are similar during in-place standing and during the support phase

  10. Exposure of Finnish population to ultraviolet radiation and radiation measurements

    International Nuclear Information System (INIS)

    Hoikkala, M.; Lappalainen, J.; Leszczynski, K.; Paile, W.

    1990-01-01

    This report is based on a survey of the literature on radiation risks involved in sunbathing and the use of solaria. The purpose of the report is to provide background information for the development of regulations on solaria and for informing the public about the risks posed by solaria and the sun. The report gives an overview of the properties and biological effects of ultraviolet radiation. The most important regulations and recommendations issued in various countries are presented. The connection between ultraviolet radiation and the risks of skin cancer is examined both on a general level and in reference to information obtained from the Finnish Cancer Registry. In Finland, the incidence of melanomas nearly tripled between 1960 and 1980. The most important cause is considered to be the population's increased exposure to the su's ultraviolet radiation. There are no reliable data on the connection between the use of solaria and the risks of skin cancer. It is estimated, however, that solaria account for less than 10 per cent of the skin cancer risk of the whole population. There are some difficult physical problems associated with the measurement of ultraviolet radiation emitted by both natural sources and solaria. A preliminary study of these problems has been undertaken by means of a survey of the available literature, supplemented by a review of measurements performed by the Finnish Centre For Radiation and Nuclear Safety. The estimated inaccuracy of the Optronic 742 spectroradiometer used by the Centre in the measurement of ultraviolet radiation emitted by the sun and solaria is about +-14%

  11. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav; Dietrich, Tobias J.; Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo; Le Corroller, Thomas

    2017-01-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  12. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Dietrich, Tobias J. [Balgrist University Hospital, Department of Radiology, Zurich (Switzerland); Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo [Siemens Healthcare GmbH, Business Area Advanced Therapies, Forchheim (Germany); Le Corroller, Thomas [Aix-Marseille Universite, CNRS, ISM UMR 7287, Marseille (France); Radiology Department, APHM, Marseille (France)

    2017-02-15

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  13. Computational methods for industrial radiation measurement applications

    International Nuclear Information System (INIS)

    Gardner, R.P.; Guo, P.; Ao, Q.

    1996-01-01

    Computational methods have been used with considerable success to complement radiation measurements in solving a wide range of industrial problems. The almost exponential growth of computer capability and applications in the last few years leads to a open-quotes black boxclose quotes mentality for radiation measurement applications. If a black box is defined as any radiation measurement device that is capable of measuring the parameters of interest when a wide range of operating and sample conditions may occur, then the development of computational methods for industrial radiation measurement applications should now be focused on the black box approach and the deduction of properties of interest from the response with acceptable accuracy and reasonable efficiency. Nowadays, increasingly better understanding of radiation physical processes, more accurate and complete fundamental physical data, and more advanced modeling and software/hardware techniques have made it possible to make giant strides in that direction with new ideas implemented with computer software. The Center for Engineering Applications of Radioisotopes (CEAR) at North Carolina State University has been working on a variety of projects in the area of radiation analyzers and gauges for accomplishing this for quite some time, and they are discussed here with emphasis on current accomplishments

  14. Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

    Science.gov (United States)

    Breslin, E H; Adams, E; Lutz, A; Roy, C

    1993-06-01

    Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

  15. Aeroradiometric Measurements In The Framework Of The ARM04 Exercise

    International Nuclear Information System (INIS)

    Bucher, B.; Butterweck, G.; Rybach, L.; Schwarz, G.

    2005-09-01

    In spring 2004 the airborne gamma spectrometry (AGS) equipment was used for the first time in a car borne survey searching for a lost 137 CS source. Initial tests showed a smooth detection of a 500 MBq 137 Cs source at a speed of 60 km/h. During the actual survey no radioactive source was found. In March 2004, the AGS equipment was employed during the exercise 'Braunbaer' of the Swiss National Emergency Operations Centre (NAZ). Three 137 Cs sources with activities of 25 MBq, 860 MBq and 890 MBq were concealed in the exercise area. As expected, the two stronger sources could be localized and identified. Additionally, the exercise demonstrated the readiness of the AGS system within the scheduled deployment time of four hours. The measurement flights within the scope of the exercise UARM04, organised by Y. Loertscher (NAZ), were performed from June 14 to June 17. According to the alternating schedule of the annual UARM exercises the environs of the nuclear power plants Beznau and Leibstadt, the environs of the research facility Paul Scherrer Institute (PSI) and of the intermediate storage facility for nuclear waste (ZWILAG) were inspected. The aeroradiometric measurements showed similar results to those observed in the past. The nuclear power plant Leibstadt could be identified by its direct radiation which is characteristic for a boiling water reactor. Block I of the nuclear power plant Beznau was in revision during the survey. The aeroradiometric measurement identified 58 Co activity, which is temporarily increasing in the fuel storage pool and in the reactor cooling system during the shut down. 60 Co could be identified over the Federal intermediate storage facility, located on the PSI area. The exhaust stack at PSI West showed an elevated amount of annihilation radiation. The intermediate storage facility Wuerenlingen (ZWILAG) could not be detected by aeroradiometric measurements. Outside the fenced areas of the inspected nuclear facilities no man-made radiation

  16. Evaluation of arm-leg coordination in flat breaststroke.

    Science.gov (United States)

    Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M

    2004-10-01

    This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.

  17. Measurement of solar radiation at the Earth's surface

    Science.gov (United States)

    Bartman, F. L.

    1982-01-01

    The characteristics of solar energy arriving at the surface of the Earth are defined and the history of solar measurements in the United States presented. Radiation and meteorological measurements being made at solar energy meteorological research and training sites and calibration procedures used there are outlined. Data illustrating the annual variation in daily solar radiation at Ann Arbor, Michigan and the diurnal variation in radiation at Albuquerque, New Mexico are presented. Direct normal solar radiation received at Albuquerque is contrasted with that received at Maynard, Massachusetts. Average measured global radiation for a period of one year for four locations under clear skies, 50% cloud cover, and 100% cloud cover is given and compared with the solar radiation at the top of the atmosphere. The May distribution of mean daily direct solar radiation and mean daily global solar radiation over the United States is presented. The effects of turbidity on the direct and circumsolar radiation are shown.

  18. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  19. Cloud Droplet Size and Liquid Water Path Retrievals From Zenith Radiance Measurements: Examples From the Atmospheric Radiation Measurement Program and the Aerosol Robotic Network

    Science.gov (United States)

    Chiu, J. C.; Marshak, A.; Huang, C.-H.; Varnai, T.; Hogan, R. J.; Giles, D. M.; Holben, B. N.; Knyazikhin, Y.; O'Connor, E. J.; Wiscombe, W. J.

    2012-01-01

    The ground-based Atmospheric Radiation Measurement Program (ARM) and NASA Aerosol Robotic Network (AERONET) routinely monitor clouds using zenith radiances at visible and near-infrared wavelengths. Using the transmittance calculated from such measurements, we have developed a new retrieval method for cloud effective droplet size and conducted extensive tests for non-precipitating liquid water clouds. The underlying principle is to combine a water-absorbing wavelength (i.e. 1640 nm) with a nonwater-absorbing wavelength for acquiring information on cloud droplet size and optical depth. For simulated stratocumulus clouds with liquid water path less than 300 g/sq m and horizontal resolution of 201m, the retrieval method underestimates the mean effective radius by 0.8 m, with a root-mean-squared error of 1.7 m and a relative deviation of 13 %. For actual observations with a liquid water path less than 450 gm.2 at the ARM Oklahoma site during 2007-2008, our 1.5 min-averaged retrievals are generally larger by around 1 m than those from combined ground-based cloud radar and microwave radiometer at a 5min temporal resolution. We also compared our retrievals to those from combined shortwave flux and microwave observations for relatively homogeneous clouds, showing that the bias between these two retrieval sets is negligible, but the error of 2.6 m and the relative deviation of 22% are larger than those found in our simulation case. Finally, the transmittance-based cloud effective droplet radii agree to better than 11% with satellite observations and have a negative bias of 1 m. Overall, the retrieval method provides reasonable cloud effective radius estimates, which can enhance the cloud products of both ARM and AERONET.

  20. Inter-arm blood pressure differences in young, healthy patients.

    Science.gov (United States)

    Grossman, Alon; Prokupetz, Alex; Gordon, Barak; Morag-Koren, Nira; Grossman, Ehud

    2013-08-01

    The prevalence and magnitude of inter-arm BP difference (IAD) in young healthy patients is not well characterized. Flight academy applicants and designated aviators undergo annual evaluation that includes blood pressure (BP) measurement on both arms. All BP measurements performed from January 1, 2012, to April 30, 2012, were recorded and IAD was calculated. Results were compared between patients in whom BP was initially measured in the right arm (group 1), those in whom BP was initially measured in the left arm (group 2), and those in whom the arm in which BP was initially measured was not recorded (group 3). A total of 877 healthy patients had BP measured during the study period. In the entire group, mean systolic BP was the same in both arms. Absolute IAD was 5.6±5.5 mm Hg for systolic and 4.7±4.5 mm Hg for diastolic BP. IAD >10 mm Hg was recorded in 111 (12.6%) and 77 (8.8%) patients for systolic and diastolic BP, respectively. IAD was the same in the 3 groups and was unrelated to age, body mass index, and heart rate, but was related to systolic BP. IAD is common in young healthy patients, is not dependent on which arm was measured first, and unrelated to age, body mass index, and heart rate. © 2013 Wiley Periodicals, Inc.

  1. On output measurements via radiation pressure

    DEFF Research Database (Denmark)

    Leeman, S.; Healey, A.J.; Forsberg, F.

    1990-01-01

    It is shown, by simple physical argument, that measurements of intensity with a radiation pressure balance should not agree with those based on calorimetric techniques. The conclusion is ultimately a consequence of the circumstance that radiation pressure measurements relate to wave momentum, while...... calorimetric methods relate to wave energy. Measurements with some typical ultrasound fields are performed with a novel type of hydrophone, and these allow an estimate to be made of the magnitude of the discrepancy to be expected between the two types of output measurement in a typical case....

  2. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  3. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    1975-10-01

    'Risk of damage' and 'exposure risk' are considered as components of the radiation risk. The influence of the 'exposure risk' on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Basing upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high 'exposure risk'. As a consequence the following recommendations are given for discussion: (a) occupationally exposed persons with small 'exposure risk' should be monitored using only a long-term dosimeter (for instance a thermoluminescence dosimeter), (b) in the case of internal exposure the surface and, if necessary, air contamination should be controlled so strictly that routine measurements of internal contamination need not be performed. (author)

  4. Quality assurance in radiation measurement

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The achievement of traceability to recognize measurement standards for ionizing radiation posses special requirements. Methods of transferring reference standard to the working situation are devised through calibration and appropriate traceability, which optimize the accuracy attainable with the method of dose determination in routine use. Appropriate procedures are developed by the SSDL-MINT to establish accurate dose measurement in wide range of radiation fields such as in medicine, agriculture and industrial application. The status of work including effort towards ISO 9000 certification of SSDL dosimetry services will be summarized. (Author)

  5. Intercomparison of Environmental Nuclear Radiation Measuring

    Institute of Scientific and Technical Information of China (English)

    GAO; Fei; NI; Ning; HOU; Jin-bing; SONG; Ming-zhe

    2015-01-01

    In 2015,Radiation Metrology Division of China Institute of Atomic Energy organized an environmental monitoring of nuclear radiation measuring intercomparison,and 9laboratories attended.The intercomparison included environmental level dosemeters and protection level

  6. Evaluation of Routine Atmospheric Sounding Measurements Using Unmanned Systems (ERASMUS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    de Boer, Gijs [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Lawrence, Dale [Univ. of Colorado, Boulder, CO (United States); Palo, Scott [Univ. of Colorado, Boulder, CO (United States); Argrow, Brian [Univ. of Colorado, Boulder, CO (United States); LoDolce, Gabriel [Univ. of Colorado, Boulder, CO (United States); Curry, Nathan [Univ. of Colorado, Boulder, CO (United States); Weibel, Douglas [Univ. of Colorado, Boulder, CO (United States); Finnamore, W [Univ. of Colorado, Boulder, CO (United States); D' Amore, P [Univ. of Colorado, Boulder, CO (United States); Borenstein, Steven [Univ. of Colorado, Boulder, CO (United States); Nichols, Tevis [Univ. of Colorado, Boulder, CO (United States); Elston, Jack [Blackswift Technologies, Boulder, CO (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bendure, Al [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Long, Chuck [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Telg, Hagen [Univ. of Colorado, Boulder, CO (United States). Cooperative Inst. for Research in Environmental Sciences (CIRES); Gao, Rushan [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States). Earth System Research Lab.; Hock, T [National Center for Atmospheric Research, Boulder, CO (United States); Bland, Geoff [National Aeronautics and Space Administration (NASA), Washington, DC (United States)

    2017-03-01

    The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) campaign was proposed with two central goals; to obtain scientifically relevant measurements of quantities related to clouds, aerosols, and radiation, including profiles of temperature, humidity, and aerosol particles, the structure of the arctic atmosphere during transitions between clear and cloudy states, measurements that would allow us to evaluate the performance of retrievals from U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility remote sensors in the Arctic atmosphere, and information on the spatial variability of heat and moisture fluxes from the arctic surface; and to demonstrate unmanned aerial system (UAS) capabilities in obtaining measurements relevant to the ARM and ASR programs, particularly for improving our understanding of Arctic clouds and aerosols.

  7. About Solar Radiation Intensity Measurements and Data Processing

    Directory of Open Access Journals (Sweden)

    MICH-VANCEA Claudiu

    2012-10-01

    Full Text Available Measuring the intensity of solar radiation is one of the directions of investigation necessary for the implementation of photovoltaic systems in a particular geographical area. This can be done by using specific measuring equipment (pyranometer sensors based onthermal or photovoltaic principle. In this paper it is presented a method for measuring solar radiation (which has two main components - direct radiation and diffuse radiation with sensors based on photovoltaic principle. Such data are processed for positioning solarpanels, in order their efficiency to be maximized.

  8. Forming positive-negative images using conditioned partial measurements from reference arm in ghost imaging.

    Science.gov (United States)

    Wen, Jianming

    2012-09-01

    A recent thermal ghost imaging experiment implemented in Wu's group [Chin. Phys. Lett. 279, 074216 (2012)] showed that both positive and negative images can be constructed by applying a novel algorithm. This algorithm allows us to form the images with the use of partial measurements from the reference arm (even which never passes through the object), conditioned on the object arm. In this paper, we present a simple theory that explains the experimental observation and provides an in-depth understanding of conventional ghost imaging. In particular, we theoretically show that the visibility of formed images through such an algorithm is not bounded by the standard value 1/3. In fact, it can ideally grow up to unity (with reduced imaging quality). Thus, the algorithm described here not only offers an alternative way to decode spatial correlation of thermal light, but also mimics a "bandpass filter" to remove the constant background such that the visibility or imaging contrast is improved. We further show that conditioned on one still object present in the test arm, it is possible to construct the object's image by sampling the available reference data.

  9. Measuring space radiation shielding effectiveness

    Directory of Open Access Journals (Sweden)

    Bahadori Amir

    2017-01-01

    Full Text Available Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  10. Measuring space radiation shielding effectiveness

    Science.gov (United States)

    Bahadori, Amir; Semones, Edward; Ewert, Michael; Broyan, James; Walker, Steven

    2017-09-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.

  11. Measurement approaches to support future warhead arms control transparency

    International Nuclear Information System (INIS)

    Olinger, C.T.; Frankle, C.M.; Johnson, M.W.; Poths, J.

    1998-01-01

    Transparency on warhead stockpiles, warhead dismantlement, and fissile material stockpiles in nuclear weapons states will become increasingly important in the move beyond START II toward lower quantities of warheads. Congressional support for further warhead reductions will likely depend on the degree of irreversibility, or in other words, the rapidity with which warhead inventories could be reconstituted. Whether irreversibility considerations can be satisfied will depend on monitoring dismantlement as well as constraining the available stockpile of fissile materials for possible refabrication into warheads. Measurement techniques designed to address the above problems will need to consider NPT Article 1 obligations as well as Russian and US classification regulations, which prohibit or restrict the transfer of nuclear warhead design information to other states. Classification considerations currently limit the potential completeness of future inspections of weapons materials. Many conventional international safeguards approaches are not currently viable for arms control applications because they would reveal weapons design information. The authors discuss a variety of technical measures that may help to improve transparence of warhead and fissile material stockpiles and may enable limited warhead dismantlement transparency

  12. measurement of indoor background ionizing radiation in some

    African Journals Online (AJOL)

    Administrator

    Measurement of the background ionizing radiation profile within the. Chemistry Research Laboratory and Physics Laboratory III all of the. University of Jos and their immediate neighbourhood were carried out. These science laboratories also harbour a number of active radiation sources. The radiation levels were measured ...

  13. Visitor’s Guide to Oliktok Point Atmospheric Radiation Measurement Climate Research Facility, North Slope of Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Desilets, Darin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Helsel, Fred M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bendure, Al O. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lucero, Daniel A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ivey, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dexheimer, Danielle N. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-04-01

    The importance of Oliktok Point, Alaska, as a focal point for climate research in the Arctic continues to grow with the addition of a U.S. Department of Energy (DOE) Atmospheric Radiation Monitoring (ARM) Climate Research Facility Mobile Facility (AMF) and the expansion of infrastructure to support airborne measurements. The site hosts a suite of instruments for making multi-year, high-fidelity atmospheric measurements; serves as a base of operations for field campaigns; and contains the only Restricted Airspace and Warning Area in the U.S. Arctic, which enables the use of unmanned aircraft systems. The use of this site by climate researchers involves several considerations, including its remoteness, harsh climate, and location amid the North Slope oilfields. This guide is intended to help visitors to Oliktok Point navigate this unique physical and administrative environment, and thereby facilitate safe and productive operations.

  14. Online radiation dose measurement system for ATLAS experiment

    International Nuclear Information System (INIS)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Bronner, J.; Hartet, J.; Franz, S.

    2009-01-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO 2 will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10 9 n/cm 2 for NIEL (non-ionizing energy loss) measurements, 10 12 n/cm 2 for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  15. Ground-based spectral measurements of solar radiation, (2)

    International Nuclear Information System (INIS)

    Murai, Keizo; Kobayashi, Masaharu; Goto, Ryozo; Yamauchi, Toyotaro

    1979-01-01

    A newly designed spectro-pyranometer was used for the measurement of the global (direct + diffuse) and the diffuse sky radiation reaching the ground. By the subtraction of the diffuse component from the global radiation, we got the direct radiation component which leads to the spectral distribution of the optical thickness (extinction coefficient) of the turbid atmosphere. The measurement of the diffuse sky radiation reveals the scattering effect of aerosols and that of the global radiation allows the estimation of total attenuation caused by scattering and absorption of aerosols. The effects of the aerosols are represented by the deviation of the real atmosphere measured from the Rayleigh atmosphere. By the combination of the measured values with those obtained by theoretical calculation for the model atmosphere, we estimated the amount of absorption by the aerosols. Very strong absorption in the ultraviolet region was recognized. (author)

  16. Portable Radiation Package (PRP) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, R Michael [Remote Measurements and Research Company, Seattle, WA (United States)

    2017-08-03

    The Portable Radiation Package (PRP) was developed to provide basic radiation information in locations such as ships at sea where proper exposure is remote and difficult, the platform is in motion, and azimuth alignment is not fixed. Development of the PRP began at Brookhaven National Laboratory (BNL) in the mid-1990s and versions of it were deployed on ships in the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Nauru-99 project. The PRP was deployed on ships in support of the National Aeronautics and Space Administration (NASA) Sensor Intercomparison for Marine Biological and Interdisciplinary Ocean Studies (SIMBIOS) program. Over the years the measurements have remained the same while the post-processing data analysis, especially for the FRSR, has evolved. This document describes the next-generation Portable Radiation Package (PRP2) that was developed for the DOE ARM Facility, under contract no. 9F-31462 from Argonne National Laboratory (ANL). The PRP2 has the same scientific principles that were well validated in prior studies, but has upgraded electronic hardware. The PRP2 approach is completely modular, both in hardware and software. Each sensor input is treated as a separate serial stream into the data collection computer. In this way the operator has complete access to each component of the system for purposes of error checking, calibration, and maintenance. The resulting system is more reliable, easier to install in complex situations, and more amenable to upgrade.

  17. Method and apparatus for determining accuracy of radiation measurements made in the presence of background radiation

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1977-01-01

    A radioactivity measuring instrument, and a method related to its use, for determining the radioactivity of a sample measured in the presence of significant background radiation, and for determining an error value relating to a specific probability of accuracy of the result are presented. Error values relating to the measurement of background radiation alone, and to the measurement of sample radiation and background radiation together, are combined to produce a true error value relating to the sample radiation alone

  18. Effects of age, sex and arm on the precision of arm position sense-left-arm superiority in healthy right-handers.

    Science.gov (United States)

    Schmidt, Lena; Depper, Lena; Kerkhoff, Georg

    2013-01-01

    Position sense is an important proprioceptive ability. Disorders of arm position sense (APS) often occur after unilateral stroke, and are associated with a negative functional outcome. In the present study we assessed horizontal APS by measuring angular deviations from a visually defined target separately for each arm in a large group of healthy subjects. We analyzed the accuracy and instability of horizontal APS as a function of age, sex and arm. Subjects were required to specify verbally the position of their unseen arm on a 0-90° circuit by comparing the current position with the target position indicated by a LED lamp, while the arm was passively moved by the examiner. Eighty-seven healthy subjects participated in the study, ranging from 20 to 77 years, subdivided into three age groups. The results revealed that APS was not a function of age or sex, but was significantly better in the non-dominant (left) arm in absolute errors (AE) but not in constant errors (CE) across all age groups of right-handed healthy subjects. This indicates a right-hemisphere superiority for left APS in right-handers and neatly fits to the more frequent and more severe left-sided body-related deficits in patients with unilateral stroke (i.e. impaired APS in left spatial neglect, somatoparaphrenia) or in individuals with abnormalities of the right cerebral hemisphere. These clinical issues will be discussed.

  19. Radiation protection measurement. Philosophy and implementation

    International Nuclear Information System (INIS)

    Recht, P.; Lakey, J.R.A.

    1975-01-01

    A selection from the proceedings of the International Symposium held by the U.K. Society for radiological protection in June 1974 was presented. The central theme was the philosophy of radiation protection measurement and its interpretation although some specific areas of good health physics practice were included. The 28 papers selected were chosen to be either representative of the central theme or of wider interest. The papers have been grouped in 6 main sections: philosophy of measurements; interpretation of measurements; implementation by legislation and monitoring; radiation exposure and control; reactor safety and siting; accidents

  20. Evaluation of Arctic broadband surface radiation measurements

    Directory of Open Access Journals (Sweden)

    N. Matsui

    2012-02-01

    Full Text Available The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW and thermal infrared, or longwave (LW, radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse SW measurements. The difference between these two quantities (that theoretically should be zero is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.

  1. Evaluation of Arctic broadband surface radiation measurements

    Science.gov (United States)

    Matsui, N.; Long, C. N.; Augustine, J.; Halliwell, D.; Uttal, T.; Longenecker, D.; Niebergall, O.; Wendell, J.; Albee, R.

    2012-02-01

    The Arctic is a challenging environment for making in-situ surface radiation measurements. A standard suite of radiation sensors is typically designed to measure incoming and outgoing shortwave (SW) and thermal infrared, or longwave (LW), radiation. Enhancements may include various sensors for measuring irradiance in narrower bandwidths. Many solar radiation/thermal infrared flux sensors utilize protective glass domes and some are mounted on complex mechanical platforms (solar trackers) that keep sensors and shading devices trained on the sun along its diurnal path. High quality measurements require striking a balance between locating stations in a pristine undisturbed setting free of artificial blockage (such as from buildings and towers) and providing accessibility to allow operators to clean and maintain the instruments. Three significant sources of erroneous data in the Arctic include solar tracker malfunctions, rime/frost/snow deposition on the protective glass domes of the radiometers and operational problems due to limited operator access in extreme weather conditions. In this study, comparisons are made between the global and component sum (direct [vertical component] + diffuse) SW measurements. The difference between these two quantities (that theoretically should be zero) is used to illustrate the magnitude and seasonality of arctic radiation flux measurement problems. The problem of rime/frost/snow deposition is investigated in more detail for one case study utilizing both SW and LW measurements. Solutions to these operational problems that utilize measurement redundancy, more sophisticated heating and ventilation strategies and a more systematic program of operational support and subsequent data quality protocols are proposed.

  2. Radiation measurement of civil air flight

    International Nuclear Information System (INIS)

    Winter, M.

    1999-01-01

    In order to aquire knowledge of the radiation exposure of civil aircrew members in common flight altitudes, it was necessary to develop a practicable measurement system. Radiation exposure was hereby estimated by using the ACREM-System, which is patented by the Austrian Research Centres Seibersdorf (OEFZS). Total Equivalent Dose could be estimated in a simple way by combining a measured component of the radiation field in flight altitudes and the results of simulation with LUIN 94 particle transport code (Keran O'Brian). To verify the results of the measurement system, a tissue equivalent proportional counter (TEPC) was used. Because of the difficult measurement conditions in cargo airplanes, special attention had to be taken to make the measurement equipment easy to use and transport. Special software has been developed to automate the measurement and the evaluation of the large amount of collected data. Measurements in standard calibration photon fields for the characterization of the equipment could be performed at the Primary Dosimetry Laboratory for Austria at the Austrian Research Centre (OEFZS) in Seibersdorf. Additional measurements were performed at Physikalisch Technische Bundesanstalt Braunschweig (PTB, Germany) and Paul Scherer Institute (PSI, Switzerland) to determine the reponse of the instruments to high energy photon and standard neutron fields. (author)

  3. Optical fibers and their applications for radiation measurements

    International Nuclear Information System (INIS)

    Kakuta, Tsunemi

    1998-01-01

    When optical fibers are used in a strong radiation field, it is necessary to increase the radiation-resistant capacity. Aiming at the improvement of such property, the characteristics of recent optical fibers made from quartz-glass were reviewed and the newly developed techniques for radiation measurement using those fibers were summarized in this report. Since optical fibers became able to use in the levels near the core conditions, their applications have started in various fields of technologies related to radiation. By combining the optical fibers and a small sensor, it became possible to act as 'Key Component' for measuring wide range radioactivity from a trace activity to a strong radiation field in the reactor core. Presently, the fibers are utilized for investigation of the optical mechanisms related in radiation, evaluation of their validities so on. Further, the optical fibers are expected to utilize in a multi-parametric measuring system which allows to concomitantly determine the radiation, temperature, pressure, flow amount etc. as an incore monitor. (M.N.)

  4. Optical fibers and their applications for radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kakuta, Tsunemi [Japan Atomic Energy Research Inst., Tokyo (Japan)

    1998-07-01

    When optical fibers are used in a strong radiation field, it is necessary to increase the radiation-resistant capacity. Aiming at the improvement of such property, the characteristics of recent optical fibers made from quartz-glass were reviewed and the newly developed techniques for radiation measurement using those fibers were summarized in this report. Since optical fibers became able to use in the levels near the core conditions, their applications have started in various fields of technologies related to radiation. By combining the optical fibers and a small sensor, it became possible to act as `Key Component` for measuring wide range radioactivity from a trace activity to a strong radiation field in the reactor core. Presently, the fibers are utilized for investigation of the optical mechanisms related in radiation, evaluation of their validities so on. Further, the optical fibers are expected to utilize in a multi-parametric measuring system which allows to concomitantly determine the radiation, temperature, pressure, flow amount etc. as an incore monitor. (M.N.)

  5. Radiation quantities, units and measurements. Final report 1999

    International Nuclear Information System (INIS)

    Wambersie, A.; Allisy, A.; Caswell, R.S.

    2000-01-01

    The determination of human exposure to radiation and radioactivity, whether arising from environmental exposures, medical practice or industrial activities, requires a fundamental set of quantities and units with which exposures can be specified and the means and ability to make measurements which yield results in terms of these quantities and units. Radiation protection then, as well as effective use of radiation in medical applications, requires the capability to accurately quantify the characteristics and extent of radiation exposure, so that appropriate and useful assessments of the potential health consequences and risks, whether for protection of the public and workers or for diagnosis and treatment of disease, can be formulated. The work carried out via this concerted action on ''Radiation quantities, units and measurements'' has addressed these needs. Measurement of radiation is a complex subject and is a science in itself. Yet many users of radiation who need to make radiation measurements cannot be expected to become experts in this particular field. They need authoritative guidance on how to deal with the measurement problems connected with their particular use of radiation. The work carried out pursuant to this concerted action has resulted in publications that meet this need. Important achievements include the publication of seven new ICRU reports, the completion of all but the printing of three other ICRU reports, completion of the drafting work on two other reports, the development of many others reports and the initiation of seven new activities that will result in ICRU reports representing important future contribution to the needs identified in this project. (orig.)

  6. Upper arm elevation and repetitive shoulder movements: a general population job exposure matrix based on expert ratings and technical measurements.

    Science.gov (United States)

    Dalbøge, Annett; Hansson, Gert-Åke; Frost, Poul; Andersen, Johan Hviid; Heilskov-Hansen, Thomas; Svendsen, Susanne Wulff

    2016-08-01

    We recently constructed a general population job exposure matrix (JEM), The Shoulder JEM, based on expert ratings. The overall aim of this study was to convert expert-rated job exposures for upper arm elevation and repetitive shoulder movements to measurement scales. The Shoulder JEM covers all Danish occupational titles, divided into 172 job groups. For 36 of these job groups, we obtained technical measurements (inclinometry) of upper arm elevation and repetitive shoulder movements. To validate the expert-rated job exposures against the measured job exposures, we used Spearman rank correlations and the explained variance[Formula: see text] according to linear regression analyses (36 job groups). We used the linear regression equations to convert the expert-rated job exposures for all 172 job groups into predicted measured job exposures. Bland-Altman analyses were used to assess the agreement between the predicted and measured job exposures. The Spearman rank correlations were 0.63 for upper arm elevation and 0.64 for repetitive shoulder movements. The expert-rated job exposures explained 64% and 41% of the variance of the measured job exposures, respectively. The corresponding calibration equations were y=0.5%time+0.16×expert rating and y=27°/s+0.47×expert rating. The mean differences between predicted and measured job exposures were zero due to calibration; the 95% limits of agreement were ±2.9% time for upper arm elevation >90° and ±33°/s for repetitive shoulder movements. The updated Shoulder JEM can be used to present exposure-response relationships on measurement scales. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  7. The low-frequency dielectric properties of octopus arm muscle measured in vivo

    International Nuclear Information System (INIS)

    Hart, F.X.; Toll, R.B.; Berner, N.J.; Bennett, N.H.

    1996-01-01

    The conductance and capacitance of octopus arm are measured in vivo over the frequency range 5 Hz to 1 MHz. Measurement of these parameters for a number of electrode separations permits the determination of the variations in tissue conductivity and dielectric constant with frequency. In the range 1-100 kHz the conductivity is independent of the frequency f and the dielectric constant varies as f -1 . These results, in conjunction with those reported previously for frog skeletal muscle, are consistent with the fractal model for the dielectric properties of animal tissue proposed by Dissado. Transformation of the results to complex impedance spectra indicates the presence of a dispersion above 100 kHz. (author)

  8. Performance measurements of a dual-rotor arm mechanism for efficient flight transition of fixed-wing unmanned aerial vehicles

    Science.gov (United States)

    McGill, Karen Ashley Jean

    Reconfigurable systems are a class of systems that can be transformed into different configurations, generally to perform unique functions or to maintain operational efficiency under distinct conditions. A UAV can be considered a reconfigurable system when coupled with various useful features such as vertical take-off and landing (VTOL), hover capability, long-range, and relatively large payload. Currently, a UAV having these capabilities is being designed by the UTSA Mechanical Engineering department. UAVs such as this one have the following potential uses: emergency response/disaster relief, hazard-critical missions, offshore oil rig/wind farm delivery, surveillance, etc. The goal of this thesis is to perform experimental thrust and power measurements for the propulsion system of this fixed-wing UAV. Focus was placed on a rotating truss arm supporting two brushless motors and rotors that will later be integrated to the ends of the UAV wing. These truss arms will rotate via a supporting shaft from 0° to 90° to transition the UAV between a vertical take-off, hover, and forward flight. To make this hover/transition possible, a relationship between thrust, arm angle, and power drawn was established by testing the performance of the arm/motor assembly at arm angles of 0°, 15°, 30°, 45°, 60°, 75°, and 90°. Universal equations for this system of thrust as a function of the arm angle were created by correlating data collected by a load cell. A Solidworks model was created and used to conduct fluid dynamics simulations of the streamlines over the arm/motor assembly.

  9. Effects of combined high intensity arm and leg training on performance and cardio-respiratory measures.

    Science.gov (United States)

    Zinner, Christoph; Sperlich, Billy; Born, Dennis-Peter; Michels, Guido

    2017-01-01

    The purpose of this study was to investigate the effects of combined arm and leg high-intensity low-volume interval training (HIITarm+leg) on maximal oxygen uptake, myocardial measures (i.e. stroke volume, cardiac output, ejection fraction), Tissue Oxygenation Index (TOI) of the vastus lateralis and triceps brachii, as well as power output in comparison to leg HIIT (HIITleg) only. The 20 healthy, male and female volunteers completed six sessions of either HIITleg on a cycle ergometer or HIITarm+leg on an arm and leg cycle ergometer. During pre- and post-testing, the volunteers completed a submaximal and incremental test to exhaustion on a cycle ergometer. Magnitude based interference revealed likely to very likely beneficial effects for HIITarm+leg compared to HIITleg in maximal oxygen uptake, cardiac measures as well peak power output. The TOI following HIITarm+leg demonstrated likely to very likely increased oxygenation in the triceps brachii or the vastus lateralis when compared to HIITleg. The results suggest that six sessions of HIITarm+leg may likely to very likely improve maximal oxygen uptake, some inotropy-related cardiac measures with improved tissue oxygenation of the triceps brachii and vastus lateralis muscles resulting in greater leg peak power output.

  10. Online radiation dose measurement system for ATLAS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Mikuz, M. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana (Slovenia); Bronner, J.; Hartet, J. [Physikalisches Institut, Universitat Freiburg, Hermann-Herder-Str. 3, Freiburg (Germany); Franz, S. [CERN, Geneva (Switzerland)

    2009-07-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO{sub 2} will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10{sup 9} n/cm{sup 2} for NIEL (non-ionizing energy loss) measurements, 10{sup 12} n/cm{sup 2} for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  11. Effectiveness estimation of camouflage measures with solar radiation and longwave radiation considered

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.S. [LG Electronics Corporation (Korea); Kauh, S.K. [Seoul National University, Seoul (Korea); Yoo, H.S. [Soongsil University, Seoul (Korea)

    1998-11-01

    Camouflage measures in military purpose utilizes the apparent temperature difference between the target and background, so it is essential to develop thermal analysis program for apparent temperature predictions and to apply some camouflage measures to real military targets for camouflage purpose. In this study, a thermal analysis program including conduction, convection and radiation is developed and the validity of radiation heat transfer terms is examined. The results show that longwave radiation along with solar radiation should be included in order to predict apparent temperature as well as physical temperature exactly. Longwave emissivity variation as an effective camouflage measures is applied to a real M2 tank. From the simulation results, it is found that an effective surface treatment, such as painting of a less emissive material or camouflage, clothing, may provide a temperature similarity or a spatial similarity, resulting in an effective camouflage. (author). 12 refs., 6 figs., 1 tab.

  12. Theoretical studies of radiative properties of broken clouds

    International Nuclear Information System (INIS)

    Titov, G.A.

    1994-01-01

    One of the three goals of the Atmospheric Radiation Measurement (ARM) Program is to improve the quality of radiation models under clear sky, homogeneous cloud, and broken cloud conditions. This report is concerned with the development of the theory of radiation transfer in the broken clouds. Our approach is based on a stochastic description of the interaction between the radiation and cloud field with stochastic geometry; In the following, we discuss (1) the mean radiation fluxes in the near IR spectral range 2.7 to 3.2 μm; (2) the influence of random geometry of individual cumulus clouds on the mean fluxes of visible solar radiation; (3) the equations of the mean radiance in the statistically inhomogeneous cloud fields

  13. The inter-arm diastolic blood pressure difference induced by one arm ischemia: a new approach to assess vascular endothelia function.

    Directory of Open Access Journals (Sweden)

    Weitong Hu

    Full Text Available OBJECTIVES: To evaluate whether inter-arm diastolic blood pressure difference (DBPl-r induced by one arm ischemia correlates with flow-mediated dilatation (FMD. METHODS: Bilateral arm BPs were simultaneously measured with two automatic devices and right brachial artery diameter (D was measured by ultrasound technique in 108 subjects (56 hypertensives and 52 normotensives. Following baseline diameter (D0 and BP measurement, right brachial artery was occluded for 5 minutes. The diameter was measured at 1, 1.5 and 2 min, and bilateral BPs measured at 3, 4 and 5 min after occlusion release. Their averages were recorded as post-D and post-BP, respectively. The difference between post-D and D0 (ΔD was calculated as the percentage increase of artery diameter (ΔD/D0. The BP difference between left and right arms was calculated as BPl-r, and the difference of post- BPl-r and baseline BPl-r was recorded as the net change of BPl-r (ΔBPl-r. RESULTS: At baseline, bilateral SBPs and DBPs were similar. Right arm ischemia induced significant DBP decline only in the right arm (68.8±12.7 vs 72.6±12.0 mmHg, P<0.05, which led to an increase of ΔDBPl-r (4.00±3.75 vs 0.78±4.47 mmHg, P<0.05. A positive correlation was seen between ΔD/D0 and ΔDBPl-r (r = 0.744, p<0.001. Furthermore, the correlation between age and ΔDBPl-r (r = -0.358, P<0.01 was similar to that between age and D/D0 (r = -0.398, P<0.01. Meanwhile, both ΔDBPl-r and ΔD/D0 were significantly lower in hypertensive patients than in normotensive patients. CONCLUSION: The inter-arm DBP difference induced by one arm ischemia may be a potential index for clinical evaluation of vascular endothelial function.

  14. Measuring space radiation shielding effectiveness

    OpenAIRE

    Bahadori Amir; Semones Edward; Ewert Michael; Broyan James; Walker Steven

    2017-01-01

    Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles ...

  15. Control measures in industrial and medical applications of radiation

    International Nuclear Information System (INIS)

    Akinloye, M. K.

    1999-01-01

    Radiation and radioactive substances are natural and permanent features of the environment; additionally the use of human made radiation is widespread. Sources of radiation are essential to modern health care, disposable medical supplies sterilized by intense radiation have been central to combating disease, radiology is a vital diagnostic tool and radiotherapy is commonly part of the treatment of malignancies. Nuclear techniques are in growing use in industry, agriculture, medicine and many fields of research, benefiting hundreds of millions of people and giving employment to millions of people in the related occupations, Irradiation is used around the world to preserve and reduce wastage and sterilization techniques have been used to eradicate disease carrying insects and pests. Industrial radiography is in routine use, for example to examine welds and detect cracks and help prevent the failure of engineered structures. It is also known that exposure to ionizing radiation can result to injuries that manifest themselves in the individual and his descendants. It is therefore imperative that the use of radiation sources be accompanied with the methods necessary for the prevention of the harmful effects of the radiation. These methods are referred to as control measures. Control measures that have been applied in establishments can be classified into physical control measures and administrative control measures. Physical control measures involve the technical aspects while administrative control measures augment physical measures. The guidelines and recommendations for the safe use of radiation and radioactive materials are provided through legislative and regulatory controls

  16. The radiation budget of stratocumulus clouds measured by tethered balloon instrumentation: Variability of flux measurements

    Science.gov (United States)

    Duda, David P.; Stephens, Graeme L.; Cox, Stephen K.

    1990-01-01

    Measurements of longwave and shortwave radiation were made using an instrument package on the NASA tethered balloon during the FIRE Marine Stratocumulus experiment. Radiation data from two pairs of pyranometers were used to obtain vertical profiles of the near-infrared and total solar fluxes through the boundary layer, while a pair of pyrgeometers supplied measurements of the longwave fluxes in the cloud layer. The radiation observations were analyzed to determine heating rates and to measure the radiative energy budget inside the stratocumulus clouds during several tethered balloon flights. The radiation fields in the cloud layer were also simulated by a two-stream radiative transfer model, which used cloud optical properties derived from microphysical measurements and Mie scattering theory.

  17. Mathematical simulation of gamma-radiation angle distribution measurements

    International Nuclear Information System (INIS)

    Batij, V.G.; Batij, E.V.; Egorov, V.V.; Fedorchenko, D.V.; Kochnev, N.A.

    2008-01-01

    We developed mathematical model of the facility for gamma-radiation angle distribution measurement and calculated response functions for gamma-radiation intensities. We developed special software for experimental data processing, the 'Shelter' object radiation spectra unfolding and Sphere detector (ShD) angle resolution estimation. Neuronet method using for detection of the radiation directions is given. We developed software based on the neuronet algorithm, that allows obtaining reliable distribution of gamma-sources that make impact on the facility detectors at the measurement point. 10 refs.; 15 figs.; 4 tab

  18. Simultaneous measurement of thermo-optic and thermal expansion coefficients with a single arm double interferometer.

    Science.gov (United States)

    Domenegueti, Jose Francisco Miras; Andrade, Acacio A; Pilla, Viviane; Zilio, Sergio Carlos

    2017-01-09

    A low-cost single arm double interferometer was developed for the concurrent measurement of linear thermal expansion (α) and thermo-optic (dn/dT) coefficients of transparent samples with plane and parallel surfaces. Owing to its common-path optical arrangement, the device is compact and stable, and allows the simultaneous measurement of interferences arising from a low-finesse Fabry-Perot etalon and from a Mach-Zehnder-type interferometer. The method was demonstrated with measurements of solid (silica, BK7, SF6) and liquid (water, ethanol and acetone) samples.

  19. Measurement of radiation damage on an optical reflector

    International Nuclear Information System (INIS)

    Peng, K.C.; Sahu, S.K.; Huang, H.C.; Ueno, K.; Chang, Y.H.; Wang, C.H.; Hou, W.S.

    1997-01-01

    We measured the radiation damage on an optical white fluorocarbon reflector called Goretex, which is to be used for aerogel threshold counters and crystal calorimeters of the BELLE detector of the KEK B-factory. Reflectance of the Goretex surface was monitored to see any effect of the radiation damage. Maximum equivalent dose was 8.6 Mrad. No radiation damage is observed within measurement errors. (orig.)

  20. Maintaining confidentiality in prospective studies: anonymous repeated measurements via email (ARME) procedure.

    Science.gov (United States)

    Carli, Vladimir; Hadlaczky, Gergö; Wasserman, Camilla; Stingelin-Giles, Nicola; Reiter-Theil, Stella; Wasserman, Danuta

    2012-02-01

    Respecting and protecting the confidentiality of data and the privacy of individuals regarding the information that they have given as participants in a research project is a cornerstone of complying with accepted research standards. However, in longitudinal studies, establishing and maintaining privacy is often challenging because of the necessity of repeated contact with participants. A novel internet-based solution is introduced here, which maintains privacy while at the same time ensures linkage of data to individual participants in a repeated measures design. With the use of the anonymous repeated measurements via email (ARME) procedure, two separate one-way communication systems are established through ad hoc email accounts and a secure study website. Strengths and limitations of the approach are discussed.

  1. Diagnostic modeling of the ARM experimental configuration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Somerville, R.C.J.

    1998-04-01

    A major accomplishment of this work was to demonstrate the viability of using in-situ data in both mid-continent North America (SGP CART site) and Tropical Western Pacific (TOGA-COARE) locations to provide the horizontal advective flux convergences which force and constrain the Single-Column Model (SCM) which was the main theoretical tool of this work. The author has used TOGA-COARE as a prototype for the ARM TWP site. Results show that SCMs can produce realistic budgets over the ARM sites without relying on parameterization-dependent operational numerical weather prediction objective analyses. The single-column model is diagnostic rather than prognostic. It is numerically integrated in time as an initial value problem which is forced and constrained by observational data. The input is an observed initial state, plus observationally derived estimates of the time-dependent advection terms in the conservation equations, provided at all model layers. Its output is a complete heat and water budget, including temperature and moisture profiles, clouds and their radiative properties, diabatic heating terms, surface energy balance components, and hydrologic cycle elements, all specified as functions of time. These SCM results should be interpreted in light of the original motivation and purpose of ARM and its goal to improve the treatment of cloud-radiation interactions in climate models.

  2. Sensor Prototype to Evaluate the Contact Force in Measuring with Coordinate Measuring Arms

    Directory of Open Access Journals (Sweden)

    Eduardo Cuesta

    2015-06-01

    Full Text Available This paper describes the design, development and evaluation tests of an integrated force sensor prototype for portable Coordinate Measuring Arms (CMAs or AACMMs. The development is based on the use of strain gauges located on the surface of the CMAs’ hard probe. The strain gauges as well as their cables and connectors have been protected with a custom case, made by Additive Manufacturing techniques (Polyjet 3D. The same method has been selected to manufacture an ergonomic handle that includes trigger mechanics and the electronic components required for synchronizing the trigger signal when probing occurs. The paper also describes the monitoring software that reads the signals in real time, the calibration procedure of the prototype and the validation tests oriented towards increasing knowledge of the forces employed in manual probing. Several experiments read and record the force in real time comparing different ways of probing (discontinuous and continuous contact and measuring different types of geometric features, from single planes to exterior cylinders, cones, or spheres, through interior features. The probing force is separated into two components allowing the influence of these strategies in probe deformation to be known. The final goal of this research is to improve the probing technique, for example by using an operator training programme, allowing extra-force peaks and bad contacts to be minimized or just to avoid bad measurements.

  3. Radiation Pressure Measurements on Micron-Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P. D.; Spann, J. F.; Witherow, W. K.; West, E. A.; Gallagher, D. L.; Adrian, M. L.; Fishman, G. J.; Tankosic, D.; LeClair, A.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

  4. Chernobyl accident: Causes, consequences and problems of radiation measurements

    International Nuclear Information System (INIS)

    Kortov, V.; Ustyantsev, Yu.

    2013-01-01

    General description of Chernobyl accident is given in the review. The accident causes are briefly described. Special attention is paid to radiation situation after the accident and radiation measurements problems. Some data on Chernobyl disaster are compared with the corresponding data on Fukushima accident. It is noted that Chernobyl and Fukushima lessons should be taken into account while developing further measures on raising nuclear industry safety. -- Highlights: ► The short comparative analysis of accidents at Chernobyl and Fukushima is given. ► We note the great effect of β-radiation on the radiation situation at Chernobyl. ► We discuss the problems of radiation measurements under these conditions. ► The impact of shelter on the radiation situation near Chernobyl NPS is described

  5. Measurement tolerance analysis of solar radiation

    Energy Technology Data Exchange (ETDEWEB)

    Cimo, J.; Maderkova, L.; Horak, J.; Igaz, D.; Pasztorova, S. [Department of Biomereorlogy and Hydrology, Slovak Agriculture University, Nitra (Slovakia)

    2012-07-01

    Solar radiant energy is bane and almost the only one source of heat for Earth 's surface and for atmosphere, and almost the only one source of energy for physical processes. Solar energy is one of the most available and the most ecological energy source. Currently the firm Kipp and Zonen belongs to prominent producer of sensors for measuring of global radiation. These sensors are the most used in our country and also in network of meteorological measurements of WMO. Therefore the two types of measuring sensors for global radiation (pyranometer PMP6, CMP 11) in comparison with calculation method Savin-Angstrom are analysed. (author)

  6. Measurements of integrated direct, diffuse and global ultraviolet-B radiation

    International Nuclear Information System (INIS)

    Utrillas, M.P.; Pedrós, R.; Gandía, S.; Gómez-Amo, J.L.; Estellés, V.; Martínez-Lozano, J.A.

    2015-01-01

    We present the first multiyear set of simultaneous measurements of the global ultraviolet-B radiation and its two components: direct and diffuse. The measurements have been taken with four YES-UVB-1 radiometers: two radiometers to measure the diffuse radiation, one provided with a shadow band and the other with a shadow disk on a Sun tracker; a radiometer to measure the global horizontal radiation; and a Sun-tracking radiometer to measure the direct radiation with an especially designed radiance collimator. The diffuse minute-values measured with both instruments agree within a coefficient correlation of 1.00. The diffuse component represents at least 50% of the global UVB (ultraviolet-B) radiation. The minute values of global UVB irradiance obtained by adding the direct and diffuse components concur with the measured global irradiance. Therefore, the measurement of the direct irradiance enables the estimation of the diffuse component, and gives an insight into the factors that affect its value, especially aerosols. - Highlights: • Simultaneous measurements of global, direct and diffuse UVB (ultraviolet-B) radiation. • The diffuse minute-values are at least 50% of the global ones. • The diffuse measurements are highly correlated to the aerosol load. • The sum of direct + diffuse radiation concur with the measured global.

  7. Radiation Measured for Chinese Satellite SJ-10 Space Mission

    Science.gov (United States)

    Zhou, Dazhuang; Sun, Yeqing; Zhang, Binquan; Zhang, Shenyi; Sun, Yueqiang; Liang, Jinbao; Zhu, Guangwu; Jing, Tao; Yuan, Bin; Zhang, Huanxin; Zhang, Meng; Wang, Wei; Zhao, Lei

    2018-02-01

    Space biological effects are mainly a result of space radiation particles with high linear energy transfer (LET); therefore, accurate measurement of high LET space radiation is vital. The radiation in low Earth orbits is composed mainly of high-energy galactic cosmic rays (GCRs), solar energetic particles, particles of radiation belts, the South Atlantic Anomaly, and the albedo neutrons and protons scattered from the Earth's atmosphere. CR-39 plastic nuclear track detectors sensitive to high LET are the best passive detectors to measure space radiation. The LET method that employs CR-39 can measure all the radiation LET spectra and quantities. CR-39 detectors can also record the incident directions and coordinates of GCR heavy ions that pass through both CR-39 and biosamples, and the impact parameter, the distance between the particle's incident point and the seed's spore, can then be determined. The radiation characteristics and impact parameter of GCR heavy ions are especially beneficial for in-depth research regarding space radiation biological effects. The payload returnable satellite SJ-10 provided an excellent opportunity to investigate space radiation biological effects with CR-39 detectors. The space bio-effects experiment was successfully conducted on board the SJ-10 satellite. This paper introduces space radiation in low Earth orbits and the LET method in radiation-related research and presents the results of nuclear tracks and biosamples hitting distributions of GCR heavy ions, the radiation LET spectra, and the quantities measured for the SJ-10 space mission. The SJ-10 bio-experiment indicated that radiation may produce significant bio-effects.

  8. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  9. Radiation thermometry - non-contact temperature measurements; Strahlungsthermometrie - Temperaturen beruehrungslos messen

    Energy Technology Data Exchange (ETDEWEB)

    Hollandt, J. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Fachbereich Hochtemperatur- und Vakuumphysik; Hartmann, J. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe Hochtemperaturskala; Gutschwager, B. [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany). Arbeitsgruppe Infrarot-Strahlungsthermometrie; Struss, O. [HEITRONICS Infrarot Messtechnik GmbH (Germany)

    2007-09-15

    The temperature is one of the measurands most frequently determined, as it decisively influences physical, chemical and biological processes. To be able to evaluate, optimize, repeat and compare industrial procedures, temperatures must be measured with sufficient accuracy and worldwide uniformity. This is done with the aid of the regulations and instructions of the international temperature scale. Today, non-contact measurements of surface temperatures can be performed without problems with radiation thermometers over a temperature range from -100 C up to 3000 C. Compared to contacting measurements, radiation-thermometric temperature measurement offers a series of advantages. Radiation thermometers react very fast and the measurement is not influenced by heat supply or dissipation. This allows objects to be measured which move very fast, are energized or may experience fast temperature changes. Consequently, radiation thermometry is increasingly used for the monitoring and control of thermal processes, for maintenance and in building services engineering. The present contribution shall inform of the fundamentals of radiation-thermometric temperature measurement as well as of the construction and popular types of radiation thermometers. It will be explained how exact and worldwide uniform temperature measurement is guaranteed via the international temperature scale and the calibration of radiation thermometers. The emissivity of surfaces which is important in practical temperature measurements and some examples of industrial applications of radiation thermometers will be described. (orig.)

  10. Radiation thermometry - non-contact temperature measurements; Strahlungsthermometrie - Temperaturen beruehrungslos messen

    Energy Technology Data Exchange (ETDEWEB)

    Hollandt, J.; Hartmann, J.; Gutschwager, B. [Physikalisch-Technische Bundesanstalt, Berlin (Germany); Struss, O. [HEITRONICS Infrarot Messtechnik GmbH, Wiesbaden (Germany)

    2006-07-01

    The temperature is one of the measurands most frequently determined, as it decisively influences physical, chemical and biological processes. To be able to evaluate, optimize, repeat and compare industrial procedures, temperatures must be measured with sufficient accuracy and worldwide uniformity. This is done with the aid of the regulations and instructions of the international temperature scale. Today, non-contact measurements of surface temperatures can be performed without problems with radiation thermometers over a temperature range from -100 C up to 3000 C. Compared to contacting measurements, radiation-thermometric temperature measurement offers a series of advantages. Radiation thermometers react very fast and the measurement is not influenced by heat supply or dissipation. This allows objects to be measured which move very fast, are energized or may experience fast temperature changes. Consequently, radiation thermometry is increasingly used for the monitoring and control of thermal processes, for maintenance and in building services engineering. The present contribution shall inform of the fundamentals of radiation-thermometric temperature measurement as well as of the construction and popular types of radiation thermometers. It will be explained how exact and worldwide uniform temperature measurement is guaranteed via the international temperature scale and the calibration of radiation thermometers. The emissivity of surfaces which is important in practical temperature measurements and some examples of industrial applications of radiation thermometers will be described. (orig.)

  11. Current situation and prospect of market on the latest radiation measuring instrument

    International Nuclear Information System (INIS)

    Ha, Chang Ho; Kim, Wang Geum; Cho, Gyu Seong

    2009-12-01

    This book deals with current situation and prospect of market on the latest radiation measuring instrument. The contents of this book are basic of technology on radiation measuring instrument with basic principle of various measuring instrument, current situation of technology and prospect of radiation measuring instrument, effect of spreading and application field of radiation measuring instrument, facility for making and research and development of radiation measuring instrument, prospect of market about radiation measuring instrument, strategy for market entry with the latest radiation measuring instrument and general prospect for the future.

  12. Radiation Pressure Measurements on Micron Size Individual Dust Grains

    Science.gov (United States)

    Abbas, M. M.; Craven, P.D.; Spann, J. F.; Tankosic, D.; Witherow, W. K.; LeClair, A.; West, E.; Sheldon, R.; Gallagher, D. L.; Adrian, M. L.

    2003-01-01

    Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

  13. Radiation monitoring data representation for duty personnel

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilov, S.L.; Kiselev, V.P.; Krasnoperov, S.N.; Kudeshov, E.V.; Maslov, S.Y.; Semin, N.N.; Sirotinskiy, S.E.; Yakovlev, V.Y. [Nuclear Safety Institute of the Russian Academy of Sciences (NSI RAS), Moscow (Russian Federation)

    2014-07-01

    Currently, Web-GIS technologies are widely used to generate a reliable and intuitive web-based interface to monitor the current radiation situation in various regions of the Russian Federation. The developed 'Server Web-Monitoring' web-application is intended for duty personnel and can operate not only on desktop computers but also on mobile devices. The subsystem of duty personnel notification about any Off-Normal Situation (ONS) (such as: critical threshold exceedances or failures in operation of monitoring systems) is also considered in the paper. Three types of Automated Radiation Monitoring Systems (ARMS) are available for monitoring: - regional ARMS; - facility-level ARMS; - ARMS of nuclear power plant surveillance areas. Google Maps and Google Maps API toolbox are used as the cartographic basis. In the general-monitoring window only general information on each of the local systems is available. Next, the operator can move to monitoring of local ARMS he is interested in. The operator can either view a list of Radiation Situation Monitoring Posts (RSMP) showing the current data in the right frame or hide it and use the map only. Viewing the log of critical threshold exceedances for 24 hours and a report on all RSMPs of a given system over the last 7 days is also possible. The report contains maximum values of measurements for every day and for each RSMP. The developed web-application includes: - monitoring of the radiation situation and its changes on the general map of the Russian Federation and on maps of local ARMS; - displaying 7-day reports for all RSMPs of the selected ARMS; - displaying the log of critical threshold exceedances recorded over the past day. The notification subsystem informs duty personnel on all ONS, namely, on critical threshold exceedances in the incoming data and failures in operation of monitoring systems. The key features of the notification subsystem are: - round-the-clock functioning; - automatic notification in case of

  14. Temperature radiation measuring equipment. Temperaturstrahlungsmessgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Lotzer, W

    1981-01-22

    The invention is concerned with a temperature radiation measuring equipment for non-contact temperature measurement by the light intensity variation method, with a photoelectric resistance as the measuring element. By having a circuit with a transistor, the 'dark resistance' occurring in the course of time is compensated for and thus gives a genuine reading (ie. the voltage drop across the photoelectric resistance remains constant).

  15. Detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    All detection or measurement of radiation rests in the possibility of recognizing the interactions of radiation with matter. When radiation passes through any kind of material medium, all or a portion of its energy is transferred to this medium. This transferred energy produces an effect in the medium. In principle, the detection of radiation is based on the appearance and the observation of this effect. In theory, all of the effects produced by radiation may be used in detecting it: in practice, the effects most commonly employed are: (1) ionization of gases (gas detectors), or of some chemical substance which is transformed by radiation (photographic or chemical dosimeters); (2) excitations in scintillators or semiconductors (scintillation counters, semiconductor counters); (3) creation of structural defects through the passage of radiation (transparent thermoluminescent and radioluminescent detectors); and (4) raising of the temperature (calorimeters). This study evaluates in detail, instruments based on the ionization of gases and the production of luminescence. In addition, the authors summarize instruments which depend on other forms of interaction, used in radiation medicine and hygiene (radiology, nuclear medicine)

  16. Measurements of the cosmic background radiation

    International Nuclear Information System (INIS)

    Weiss, R.

    1980-01-01

    Measurements of the attributes of the 2.7-K microwave background radiation (CBR) are reviewed, with emphasis on the analytic phase of CBR studies. Methods for the direct measurement of the CBR spectrum are discussed. Attention is given to receivers, antennas, absolute receiver calibration, atmospheric emission and absorption, the galactic background contribution, the analysis of LF measurements, and recent HF observations of the CBR spectrum. Measurements of the large-angular-scale intensity distribution of the CBR (the most convincing evidence that the radiation is of cosmological origin) are examined, along with limits on the linear polarization of the CBR. A description is given of the NASA-sponsored Cosmic Background Explorer (COBE) satellite mission. The results of the COBE mission will be a set of sky maps showing, in the wave number range from 1 to 10,000 kaysers, the galactic background radiation due to synchrotron emission from galactic cosmic rays, to diffuse thermal emission from H II regions, and to diffuse thermal emission from interstellar and interplanetary dust, as well as a residue consisting of the CBR and whatever other cosmological background might exist

  17. Environmental Gamma Radiation Measurements in Baskil District

    International Nuclear Information System (INIS)

    Canbazoglu, C.

    2008-01-01

    In this study, we have determined environmental gamma radiation dose rate in Baskil district which has very high granite content in its geographical structure. Gamma radiation dose rate measurements were achieved by portable radiation monitoring equipment based on the energy range between 40 keV and 1.3 MeV. The measurements were performed on asphalt and soil surface level and also one meter above the ground surface. The gamma dose rate was also performed inside and outside of buildings over the district. The dose rates were found to be between 8.46μR/h and 34.66 μR/h. Indoor and outdoor effective dose rate of the gamma radiation exposure has been calculated to be 523μSv/y and 196μSv/y, respectively

  18. Midupper Arm Circumference Outperforms Weight-Based Measures of Nutritional Status in Children with Diarrhea.

    Science.gov (United States)

    Modi, Payal; Nasrin, Sabiha; Hawes, Meagan; Glavis-Bloom, Justin; Alam, Nur H; Hossain, M Iqbal; Levine, Adam C

    2015-07-01

    Undernutrition contributes to 45% of all deaths in children children with diarrhea and possible dehydration. This study assessed the validity of different measures of undernutrition in children with diarrhea. A prospective cohort study was conducted at an urban hospital in Bangladesh. Children children for screening, of which 1025 were eligible, 850 were enrolled, and 721 had complete data for analysis. Anthropometric measurements, including weight-for-age z score (WAZ), weight-for-length z score (WLZ), midupper arm circumference (MUAC), and midupper arm circumference z score (MUACZ), were calculated pre- and posthydration in all patients. Measurements were evaluated for their ability to correctly identify undernutrition in children with varying degrees of dehydration. Of the 721 patients with full data for analysis, the median percent dehydration was 4%. Of the 4 measures evaluated, MUAC and MUACZ demonstrated 92-94% agreement pre- and posthydration compared with 69-76% for WAZ and WLZ. Although each 1% change in hydration status was found to change weight-for-age by 0.0895 z scores and weight-for-length by 0.1304 z scores, MUAC and MUACZ were not significantly affected by dehydration status. Weight-based measures misclassified 12% of children with severe underweight and 14% with severe acute malnutrition (SAM) compared with only 1-2% for MUAC and MUACZ. MUAC and MUACZ were the most accurate predictors of undernutrition in children with diarrhea. WAZ and WLZ were significantly affected by dehydration status, leading to the misdiagnosis of many patients on arrival with severe underweight and SAM. This trial was registered at clinicaltrials.gov as NCT02007733. © 2015 American Society for Nutrition.

  19. Automated System of Area Radiation Measurement (ASARM)

    International Nuclear Information System (INIS)

    Hernandez G, J.

    2013-10-01

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  20. Environmental radiation measurements and remedial actions (Hantepe/Ezine/Canakkale)

    International Nuclear Information System (INIS)

    2009-01-01

    There are some regions in the world that are known as high background radiation areas. Intensive scientific investigations in the field of radiation dose and health effects, risk estimates, radiation protection, environmental transportation routes and ecological effects related with natural radiation have been carried out in these regions. Also natural radiation dosimetry, in vitro and in vivo biological studies which take into account the measurements in the field of low level radiation, radon, thoron and cosmic rays have been carried out, again in these regions. The well-known high natural background radiation areas in the world are Guarapari in Brazil, Ramsar in Iran, Kerala in India and Yangjiang in China. In addition to above mentioned areas, other relatively lower high background radiation areas are exist. Since 1960s, radiological, geological, epidemiological and ecological studies have been carried out in order to determine the risks and possible health effects of long-term low level natural radiation exposure. In the framework of surveying the background radiation of Turkey, the background radiation measurements were carried out in 56 different points around the area of Canakkale city. The radiation levels at Hantepe beach of Geyikli which is located in Ezine town of Canakkale was found higher than the mean background radiation level of the region. The radiation dose rates were measured in between 0.20 and 10.88 Gy h-1 in contact and 0.27 and 3.11 Gy h-1 above 1 meter of the ground level where the thorium-containing sand is dense. After the rehabilitation studies, the radiation dose rate were measured in between 0.15 and 8.09 Gy h-1 in contact and 0.17 and 2.88 Gy h-1 above 1 meter of the ground level. It was observed that the radiation dose rates were decreased seriously after the rehabilitation studies when the arithmetic mean value of the dose rates was taken into account. The effective dose calculations were performed by taking into account the

  1. Planet-driven Spiral Arms in Protoplanetary Disks. II. Implications

    Science.gov (United States)

    Bae, Jaehan; Zhu, Zhaohuan

    2018-06-01

    We examine whether various characteristics of planet-driven spiral arms can be used to constrain the masses of unseen planets and their positions within their disks. By carrying out two-dimensional hydrodynamic simulations varying planet mass and disk gas temperature, we find that a larger number of spiral arms form with a smaller planet mass and a lower disk temperature. A planet excites two or more spiral arms interior to its orbit for a range of disk temperatures characterized by the disk aspect ratio 0.04≤slant {(h/r)}p≤slant 0.15, whereas exterior to a planet’s orbit multiple spiral arms can form only in cold disks with {(h/r)}p≲ 0.06. Constraining the planet mass with the pitch angle of spiral arms requires accurate disk temperature measurements that might be challenging even with ALMA. However, the property that the pitch angle of planet-driven spiral arms decreases away from the planet can be a powerful diagnostic to determine whether the planet is located interior or exterior to the observed spirals. The arm-to-arm separations increase as a function of planet mass, consistent with previous studies; however, the exact slope depends on disk temperature as well as the radial location where the arm-to-arm separations are measured. We apply these diagnostics to the spiral arms seen in MWC 758 and Elias 2–27. As shown in Bae et al., planet-driven spiral arms can create concentric rings and gaps, which can produce a more dominant observable signature than spiral arms under certain circumstances. We discuss the observability of planet-driven spiral arms versus rings and gaps.

  2. Trigonometric parallaxes of star forming regions in the Scutum spiral arm

    International Nuclear Information System (INIS)

    Sato, M.; Wu, Y. W.; Immer, K.; Zhang, B.; Sanna, A.; Brunthaler, A.; Menten, K. M.; Reid, M. J.; Dame, T. M.

    2014-01-01

    We report measurements of trigonometric parallaxes for six high-mass star-forming regions in the Scutum spiral arm of the Milky Way as part of the BeSSeL Survey. Combining our measurements with 10 previous measurements from the BeSSeL Survey yields a total sample of 16 sources in the Scutum arm with trigonometric parallaxes in the Galactic longitude range from 5° to 32°. Assuming a logarithmic spiral model, we estimate a pitch angle of 19.°8 ± 3.°1 for the Scutum arm, which is larger than pitch angles reported for other spiral arms. The high pitch angle of the arm may be due to the arm's proximity to the Galactic bar. The Scutum arm sources show an average peculiar motion of 4 km s –1 slower than the Galactic rotation and 8 km s –1 toward the Galactic center. While the direction of this non-circular motion has the same sign as determined for sources in other spiral arms, the motion toward the Galactic center is greater for the Scutum arm sources.

  3. Differential Detector for Measuring Radiation Fields

    International Nuclear Information System (INIS)

    Broide, A.; Marcus, E.; Brandys, I.; Schwartz, A.; Wengrowicz, U.; Levinson, S.; Seif, R.; Sattinger, D.; Kadmon, Y.; Tal, N.

    2004-01-01

    In case of a nuclear accident, it is essential to determine the source of radioactive contamination in order to analyze the risk to the environment and to the population. The radiation source may be a radioactive plume on the air or an area on the ground contaminated with radionuclides. Most commercial radiation detectors measure only the radiation field intensity but are unable to differentiate between the radiation sources. Consequently, this limitation causes a real problem in analyzing the potential risk to the near-by environment, since there is no data concerning the contamination ratios in the air and on the ground and this prevents us from taking the required steps to deal with the radiation event. This work presents a GM-tube-based Differential Detector, which enables to determine the source of contamination

  4. Randomized trial of opioids versus tricyclic antidepressants for radiation-induced mucositis pain in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ehrnrooth, E.; Grau, C.; Zachariae, R.; Andersen, Joern [Aarhus Univ. Hospital (Denmark). Dept. of Oncology

    2001-11-01

    Patients who receive radiotherapy for head and neck cancer are likely to develop painful mucositis. The pain is characterized by a burning or stinging sensation similar to neuropathic pain sensations. The purpose of the present study was to compare the analgesic effect of a tricyclic antidepressant (TC), commonly used in the treatment of neuropathic pain, with the effect of opioids on radiation-induced mucositis pain. Forty-three patients receiving 66-68 Gy external radiation according to the DAHANCA guidelines (the Danish Head and Neck Cancer Study Group) were randomized to either morphine or TC when mucositis pain was insufficiently managed with weak analgesics. Patients with insufficient pain control in either treatment arm received supplementary medication from the opposite treatment arm. Pain was evaluated weekly using a VAS scale and the McGill Pain Questionnaire. The degree of mucositis and the degree of depression were measured at the same time intervals. Twenty-two patients entered the opioid arm and 21 the TC arm. Two patients in each arm were non-evaluable. VAS pain scores were significantly reduced in the opioid treatment arm one week after randomization (p=0.01). Eight patients in the TC arm were managed with TC alone, but for 11 patients it was necessary to add morphine. The 20 evaluable patients in the morphine arm required no additional treatment. There were no significant differences in side effects between the two groups. Higher pain scores in the TC arm, but not in the opioid arm, were significantly correlated with higher BDI scores. Some head and neck cancer patients with radiation-induced nucositis pain may have sufficient pain control on TC alone. This might be useful in patients with relative counter-indications to opioid treatment.

  5. Randomized trial of opioids versus tricyclic antidepressants for radiation-induced mucositis pain in head and neck cancer

    International Nuclear Information System (INIS)

    Ehrnrooth, E.; Grau, C.; Zachariae, R.; Andersen, Joern

    2001-01-01

    Patients who receive radiotherapy for head and neck cancer are likely to develop painful mucositis. The pain is characterized by a burning or stinging sensation similar to neuropathic pain sensations. The purpose of the present study was to compare the analgesic effect of a tricyclic antidepressant (TC), commonly used in the treatment of neuropathic pain, with the effect of opioids on radiation-induced mucositis pain. Forty-three patients receiving 66-68 Gy external radiation according to the DAHANCA guidelines (the Danish Head and Neck Cancer Study Group) were randomized to either morphine or TC when mucositis pain was insufficiently managed with weak analgesics. Patients with insufficient pain control in either treatment arm received supplementary medication from the opposite treatment arm. Pain was evaluated weekly using a VAS scale and the McGill Pain Questionnaire. The degree of mucositis and the degree of depression were measured at the same time intervals. Twenty-two patients entered the opioid arm and 21 the TC arm. Two patients in each arm were non-evaluable. VAS pain scores were significantly reduced in the opioid treatment arm one week after randomization (p=0.01). Eight patients in the TC arm were managed with TC alone, but for 11 patients it was necessary to add morphine. The 20 evaluable patients in the morphine arm required no additional treatment. There were no significant differences in side effects between the two groups. Higher pain scores in the TC arm, but not in the opioid arm, were significantly correlated with higher BDI scores. Some head and neck cancer patients with radiation-induced nucositis pain may have sufficient pain control on TC alone. This might be useful in patients with relative counter-indications to opioid treatment

  6. Equilibrium-point control hypothesis examined by measured arm stiffness during multijoint movement.

    Science.gov (United States)

    Gomi, H; Kawato

    1996-04-05

    For the last 20 years, it has been hypothesized that well-coordinated, multijoint movements are executed without complex computation by the brain, with the use of springlike muscle properties and peripheral neural feedback loops. However, it has been technically and conceptually difficult to examine this "equilibrium-point control" hypothesis directly in physiological or behavioral experiments. A high-performance manipulandum was developed and used here to measure human arm stiffness, the magnitude of which during multijoint movement is important for this hypothesis. Here, the equilibrium-point trajectory was estimated from the measured stiffness, the actual trajectory, and the generated torque. Its velocity profile differed from that of the actual trajectory. These results argue against the hypothesis that the brain sends as a motor command only an equilibrium-point trajectory similar to the actual trajectory.

  7. Neutron measuring instruments for radiation protection

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Schneider, W.; Hoefert, M.; Kuehn, H.; Jahr, R.; Wagner, S.; Piesch, E.

    1979-09-01

    The present report deals with selected topics from the field of neutron dosimetry for radiation protection connected with the work of the subcommittee 6802 in the Standards Committee on Radiology (NAR) of the German Standards Institute (DIN). It is a sort of material collection. The topics are: 1. Measurement of the absorbed-energy dose by a) ionization chambers in fields of mixed radiation and b) recoil-proton proportional counting tubes. 2. Measurement of the equivalent dose, neutron monitors, combination methods by a) rem-meters, b) recoil-proton counting tubes, c) recombination method, tissue-equivalent proportional counters, activation methods for high energies in fields of mixed radiation, d) personnel dosimetry by means of ionization chambers and counting tubes, e) dosimetry by means of activation methods, nuclear track films, nonphotographic nuclear track detectors and solid-state dosimeters. (orig./HP) [de

  8. MEASURING TEMPORAL PHOTON BUNCHING IN BLACKBODY RADIATION

    Energy Technology Data Exchange (ETDEWEB)

    Tan, P. K.; Poh, H. S.; Kurtsiefer, C. [Center for Quantum Technologies, 3 Science Drive 2, 117543 (Singapore); Yeo, G. H.; Chan, A. H., E-mail: pengkian@physics.org, E-mail: phyck@nus.edu.sg [Department of Physics, National University of Singapore, 2 Science Drive 3, 117551 (Singapore)

    2014-07-01

    Light from thermal blackbody radiators such as stars exhibits photon bunching behavior at sufficiently short timescales. However, with available detector bandwidths, this bunching signal is difficult to observe directly. We present an experimental technique to increase the photon bunching signal in blackbody radiation via spectral filtering of the light source. Our measurements reveal strong temporal photon bunching from blackbody radiation, including the Sun. This technique allows for an absolute measurement of the photon bunching signature g {sup (2)}(0), and thereby a direct statement on the statistical nature of a light source. Such filtering techniques may help revive the interest in intensity interferometry as a tool in astronomy.

  9. Modeling of clouds and radiation for development of parameterizations for general circulation models

    International Nuclear Information System (INIS)

    Westphal, D.; Toon, B.; Jensen, E.; Kinne, S.; Ackerman, A.; Bergstrom, R.; Walker, A.

    1994-01-01

    Atmospheric Radiation Measurement (ARM) Program research at NASA Ames Research Center (ARC) includes radiative transfer modeling, cirrus cloud microphysics, and stratus cloud modeling. These efforts are designed to provide the basis for improving cloud and radiation parameterizations in our main effort: mesoscale cloud modeling. The range of non-convective cloud models used by the ARM modeling community can be crudely categorized based on the number of predicted hydrometers such as cloud water, ice water, rain, snow, graupel, etc. The simplest model has no predicted hydrometers and diagnoses the presence of clouds based on the predicted relative humidity. The vast majority of cloud models have two or more predictive bulk hydrometers and are termed either bulk water (BW) or size-resolving (SR) schemes. This study compares the various cloud models within the same dynamical framework, and compares results with observations rather than climate statistics

  10. Seismic restraint means for radiation detector

    International Nuclear Information System (INIS)

    Underwood, R.H.; Todt, W.H.

    1983-01-01

    Seismic restraint means are provided for mounting an elongated, generally cylindrical nuclear radiation detector within a tubular thimble in a nuclear reactor monitor system. The restraint means permits longitudinal movement of the radiation detector into and out of the thimble. Each restraint means comprises a split clamp ring and a plurality of symmetrically spaced support arms pivotally mounted on the clamp ring. Each support arm has spring bias means and thimble contact means eg insulating rollers whereby the contact means engage the thimble with a constant predetermined force which minimizes seismic vibration action on the radiation detector. (author)

  11. Measuring scatter radiation in diagnostic x rays for radiation protection purposes

    International Nuclear Information System (INIS)

    Panayiotakis, George; Vlachos, Ioannis; Delis, Harry; Tsantilas, Xenophon; Kalyvas, Nektarios; Kandarakis, Ioannis

    2015-01-01

    During the last decades, radiation protection and dosimetry in medical X-ray imaging practice has been extensively studied. The purpose of this study was to measure secondary radiation in a conventional radiographic room, in terms of ambient dose rate equivalent H*(10) and its dependence on the radiographic exposure parameters such as X-ray tube voltage, tube current and distance. With some exceptions, the results indicated that the scattered radiation was uniform in the space around the water cylindrical phantom. The results also showed that the tube voltage and filtration affect the dose rate due to the scatter radiation. Finally, the scattered X-ray energy distribution was experimentally calculated. (authors)

  12. Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a 'large circumference'?

    Science.gov (United States)

    Fonseca-Reyes, Salvador; de Alba-García, Javier García; Parra-Carrillo, José Z; Paczka-Zapata, José Antonio

    2003-06-01

    To measure the effect on blood pressure readings when a standard cuff is used on patients with arms of a large circumference, and to determine the frequency of arms of a large circumference. Blood pressures were taken in 120 subjects with an arm circumference greater than 33 cm. Also, the arm circumference was determined in 244 patients from a family health unit, and in 216 patients from a hypertension clinic. A mercury sphygmomanometer and two different cuff sizes were used in a random sequence; therefore, 60 patients' blood pressure were first measured with a large cuff, followed by a standard cuff; the opposite sequence was then applied for another 60 patients. With the obtained values and using a regression analysis, the difference in blood pressure overestimation was calculated. Arm circumference measurement percentages were used to determine the frequency of arms of a large circumference. Both systolic and diastolic blood pressures were significantly greater when the standard cuff was used. For every 5 cm increase in arm circumference, starting at 35 cm, a 2-5 mmHg increase in systolic blood pressure, and a 1-3 mmHg increase in diastolic blood pressure was observed. The prevalence of arms with a large circumference in the family medicine unit and hypertension clinic was 42% and 41.8%, respectively. There is an overestimation of blood pressure when a standard cuff is used in obese subjects. The high prevalence of these individuals in our environment, both in the hypertensive and normotensive population, makes it necessary to have on hand different sizes of cuffs for taking blood pressure in order to avoid incorrect decisions.

  13. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  14. Galaxy Zoo: constraining the origin of spiral arms

    Science.gov (United States)

    Hart, Ross E.; Bamford, Steven P.; Keel, William C.; Kruk, Sandor J.; Masters, Karen L.; Simmons, Brooke D.; Smethurst, Rebecca J.

    2018-05-01

    Since the discovery that the majority of low-redshift galaxies exhibit some level of spiral structure, a number of theories have been proposed as to why these patterns exist. A popular explanation is a process known as swing amplification, yet there is no observational evidence to prove that such a mechanism is at play. By using a number of measured properties of galaxies, and scaling relations where there are no direct measurements, we model samples of SDSS and S4G spiral galaxies in terms of their relative halo, bulge and disc mass and size. Using these models, we test predictions of swing amplification theory with respect to directly measured spiral arm numbers from Galaxy Zoo 2. We find that neither a universal cored or cuspy inner dark matter profile can correctly predict observed numbers of arms in galaxies. However, by invoking a halo contraction/expansion model, a clear bimodality in the spiral galaxy population emerges. Approximately 40 per cent of unbarred spiral galaxies at z ≲ 0.1 and M* ≳ 1010M⊙ have spiral arms that can be modelled by swing amplification. This population display a significant correlation between predicted and observed spiral arm numbers, evidence that they are swing amplified modes. The remainder are dominated by two-arm systems for which the model predicts significantly higher arm numbers. These are likely driven by tidal interactions or other mechanisms.

  15. Nuclear radiation-warning detector that measures impedance

    Science.gov (United States)

    Savignac, Noel Felix; Gomez, Leo S; Yelton, William Graham; Robinson, Alex; Limmer, Steven

    2013-06-04

    This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

  16. Aerosol measurements at the Southern Great Plains Site: Design and surface installation

    Energy Technology Data Exchange (ETDEWEB)

    Leifer, R.; Knuth, R.H.; Guggenheim, S.F.; Albert, B. [Department of Energy, New York, NY (United States)

    1996-04-01

    To impropve the predictive capabilities of the Atmospheric Radiation Measurements (ARM) program radiation models, measurements of awserosol size distributions, condensation particle concentrations, aerosol scattering coefficients at a number of wavelenghts, and the aerosol absorption coefficients are needed at the Southern Great Plains (SGP) site. Alos, continuous measurements of ozone concnetrations are needed for model validation. The environmental Measuremenr Laboratory (EMK) has the responsibility to establish the surface aerosol measurements program at the SGP site. EML has designed a special sampling manifold.

  17. Informatics in radiology: use of a C-arm fluoroscopy simulator to support training in intraoperative radiography.

    Science.gov (United States)

    Bott, Oliver Johannes; Dresing, Klaus; Wagner, Markus; Raab, Björn-Werner; Teistler, Michael

    2011-01-01

    Mobile image intensifier systems (C-arms) are used frequently in orthopedic and reconstructive surgery, especially in trauma and emergency settings, but image quality and radiation exposure levels may vary widely, depending on the extent of the C-arm operator's knowledge and experience. Current training programs consist mainly of theoretical instruction in C-arm operation, the physical foundations of radiography, and radiation avoidance, and are largely lacking in hands-on application. A computer-based simulation program such as that tested by the authors may be one way to improve the effectiveness of C-arm training. In computer simulations of various scenarios commonly encountered in the operating room, trainees using the virtX program interact with three-dimensional models to test their knowledge base and improve their skill levels. Radiographs showing the simulated patient anatomy and surgical implants are "reconstructed" from data computed on the basis of the trainee's positioning of models of a C-arm, patient, and table, and are displayed in real time on the desktop monitor. Trainee performance is signaled in real time by color graphics in several control panels and, on completion of the exercise, is compared in detail with the performance of an expert operator. Testing of this computer-based training program in continuing medical education courses for operating room personnel showed an improvement in the overall understanding of underlying principles of intraoperative radiography performed with a C-arm, with resultant higher image quality, lower overall radiation exposure, and greater time efficiency. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105125/-/DC1. Copyright © RSNA, 2011.

  18. Arm Volumetry Versus Upper Extremity Lymphedema Index: Validity of Upper Extremity Lymphedema Index for Body-Type Corrected Arm Volume Evaluation.

    Science.gov (United States)

    Yamamoto, Nana; Yamamoto, Takumi; Hayashi, Nobuko; Hayashi, Akitatsu; Iida, Takuya; Koshima, Isao

    2016-06-01

    Volumetry, measurement of extremity volume, is a commonly used method for upper extremity lymphedema (UEL) evaluation. However, comparison between different patients with different physiques is difficult with volumetry, because body-type difference greatly affects arm volume. Seventy arms of 35 participants who had no history of arm edema or breast cancer were evaluated. Arm volume was calculated using a summed truncated cone model, and UEL index was calculated using circumferences and body mass index (BMI). Examinees' BMI was classified into 3 groups, namely, low BMI (BMI, 25 kg/m). Arm volume and UEL index were compared with corresponding BMI groups. Mean (SD) arm volume was 1090.9 (205.5) mL, and UEL index 96.9 (5.6). There were significant differences in arm volume between BMI groups [low BMI vs middle BMI vs high BMI, 945.2 (107.4) vs 1045.2 (87.5) vs 1443.1 (244.4) mL, P 0.5]. Arm volume significantly increased with increase of BMI, whereas UEL index stayed constant regardless of BMI. Upper extremity lymphedema index would allow better body-type corrected arm volume evaluation compared with arm volumetry.

  19. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  20. Aerosol single-scattering albedo and asymmetry parameter from MFRSR observations during the ARM Aerosol IOP 2003

    Directory of Open Access Journals (Sweden)

    E. I. Kassianov

    2007-06-01

    Full Text Available Multi-filter Rotating Shadowband Radiometers (MFRSRs provide routine measurements of the aerosol optical depth (τ at six wavelengths (0.415, 0.5, 0.615, 0.673, 0.870 and 0.94 μm. The single-scattering albedo (π0 is typically estimated from the MFRSR measurements by assuming the asymmetry parameter (g. In most instances, however, it is not easy to set an appropriate value of g due to its strong temporal and spatial variability. Here, we introduce and validate an updated version of our retrieval technique that allows one to estimate simultaneously π0 and g for different types of aerosol. We use the aerosol and radiative properties obtained during the Atmospheric Radiation Measurement (ARM Program's Aerosol Intensive Operational Period (IOP to validate our retrieval in two ways. First, the MFRSR-retrieved optical properties are compared with those obtained from independent surface, Aerosol Robotic Network (AERONET, and aircraft measurements. The MFRSR-retrieved optical properties are in reasonable agreement with these independent measurements. Second, we perform radiative closure experiments using the MFRSR-retrieved optical properties. The calculated broadband values of the direct and diffuse fluxes are comparable (~5 W/m2 to those obtained from measurements.

  1. Evaluation of the knowledge of the French armed forces health service after a regulatory training in patients' radiation protection

    International Nuclear Information System (INIS)

    Nombo, M.; Gagna, G.; Lahutte, M.; Bourguignon, M.; Amabile, J.-C.

    2017-01-01

    According to the Public Health Code, all the professionals who perform therapeutic or diagnostic acts with ionizing radiation (IR) and the professionals involved in the implementation of these acts and the maintenance of the equipment should be given theoretical and practical training. Such training must focus on the protection of the people exposed to IR for medical purposes. Knowledge should be updated at least every 10 years, under the Nuclear Safety Authority. For the Ministry of Defense, the Military School of the Val-de-Grace offers a training day dedicated to the health-care professionals of the Military Hospitals and the forces using or prescribing examinations requiring ionizing radiation. The objective of the study was to assess the efficiency of this training day on patients' radiation protection organized for the French Armed Forces Health Service; the study was carried out with questionnaires assessing the knowledge and the quality of the interventions. A multicentric prospective study was conducted from September 2013 to November 2014 in four Military Hospitals (Val-de- Grace, St. Anne, Percy and Legouest) on French Armed Forces Health Service professionals who agreed to answer a questionnaire containing 50 multiple choice questions, both at the beginning and at the end of the training day. The analysis was focused on the comparison of the scores obtained before and after the training (overall ratings, by profession and according to the monitoring of previous training or not). The results of the primary care physicians' questionnaires were of particular interest (physicians serving in military units). The results were obtained from a total of 126 respondents over five training sessions in the four Military Hospitals. A significant 18% increase of the overall score after training according to the Student's test with p < 0.001 was observed. However, there was no significant difference between the results obtained by the professionals who

  2. Radiation detector device for measuring ionizing radiation

    International Nuclear Information System (INIS)

    Brake, D. von der.

    1983-01-01

    The device contains a compensating filter circuit, which guarantees measurement of the radiation dose independent of the energy or independent of the energy and direction. The compensating filter circuit contains a carrier tube of a slightly absorbing metal with an order number not higher than 35, which surrounds a tubular detector and which carries several annular filter parts on its surface. (orig./HP) [de

  3. Calorimeter with capacitance transducer for measurement of SHF radiation power

    International Nuclear Information System (INIS)

    Kiselev, V.A.; Linnik, A.F.; Onishchenko, I.N.; Uskov, V.V.

    2005-01-01

    A calorimeter of simple design for measuring total energy of microwave radiation is described. It operates in the energy range of 0.5 J to 6 kJ; water is used as the absorbing material. A capacitive probe is applied to measure changes in the water volume. The energy absorption factor of electromagnetic radiation in the range of 3-60 GHz is at least 0.9. The calorimeter is insensitive to radiation field nonuniformity over the absorber volume. The calorimeter is intended for measuring the radiation energy of beam plasma generators and generators with dielectric structure. Its design makes it possible to simultaneously measure the radiation energy and monitor the beam current [ru

  4. Automatic radiation measuring system connected with GPS

    International Nuclear Information System (INIS)

    Tanigaki, Minoru

    2014-01-01

    The most serious nuclear disaster in Japan has broken out at Fukushima Daiichi Nuclear Power Plant due to Great East Japan Earthquake. Prompt and exact mapping of the contamination is of great importance for radiation protection and for the environment restoration. We have developed radiation survey systems KURAMA and KURAMA-2 for rapid and exact measurement of radiation dose distribution. The system is composed of a mobile radiation monitor and the computer in office which is for the storage and visualization of the data. They are connected with internet and are operated for continuous radiation measurement while the monitor is moving. The mobile part consists of a survey meter, an interface to transform the output of the survey meter for the computer, a global positioning system, a computer to process the data for connecting to the network, and a mobile router. Thus they are effective for rapid mapping of the surface contamination. The operation and the performance of the equipment at the site are presented. (J.P.N.)

  5. Development of a mobile robot for remote radiation measurement

    International Nuclear Information System (INIS)

    Sarkar, Ushnish; Saini, Surendra Singh; Swaroop, Tumapala Teja; Sreejith, P.; Kumar, Ravinder; Ray, Debasish Datta

    2016-01-01

    Remote measurement of radiation using mobile robots is recommended in nuclear installations. For this purpose various robots have been developed that carry a radiation sensor. However since the robot has to go very near to the source of radiation, the life of the robot's components is compromised due to high level of absorbed dose. It was earlier managed to increase the life expectancy of remote radiation measurement robots by allowing the sensor to be placed on an extendable telescopic assembly; analogous to a health physicist taking measurements using a Teletector. The first prototype developed had stair climbing capabilities but it was found to be over dimensioned for various potential applications. A significant use of such robots is in taking measurements at nuclear reprocessing facilities having narrow cluttered pathways. This required development of a new version of the robot capable of negotiating the narrow pathways of such facilities. This paper describes the different aspects of the development of the mobile robot system with flexible radiation sensing capabilities

  6. Pion radiation for high grade astrocytoma: results of a randomized study

    International Nuclear Information System (INIS)

    Pickles, Tom; Goodman, George B.; Rheaume, Dorianne E.; Duncan, Graeme G.; Fryer, Chris J.; Bhimji, Shamim; Ludgate, Charles; Syndikus, Isabel; Graham, Peter; Dimitrov, Mario; Bowen, Julie

    1997-01-01

    Purpose: This study attempted to compare within a randomized study the outcome of pion radiation therapy vs. conventional photon irradiation for the treatment of high-grade astrocytomas. Methods and Materials: Eighty-four patients were randomized to pion therapy (33-34.5 Gyπ), or conventional photon irradiation (60 Gy). Entry criteria included astrocytoma (modified Kernohan high Grade 3 or Grade 4), age 18-70, Karnofsky performance status (KPS) ≥50, ability to start irradiation within 30 days of surgery, unifocal tumor, and treatment volume < 850 cc. The high-dose volume in both arms was computed tomography enhancement plus a 2-cm margin. The study was designed with the power to detect a twofold difference between arms. Results: Eighty-one eligible patients were equally balanced for all known prognostic variables. Pion patients started radiation 7 days earlier on average than photon patients, but other treatment-related variables did not differ. There were no significant differences for either early or late radiation toxicity between treatment arms. Actuarial survival analysis shows no differences in terms of time to local recurrence or overall survival where median survival was 10 months in both arms (p = 0.22). The physician-assessed KPS and patient-assessed quality of life (QOL) measurements were generally maintained within 10 percentage points until shortly before tumor recurrence. There was no apparent difference in the serial KPS or QOL scores between treatment arms. Conclusion: In contrast to high linear energy transfer (LET) therapy for central nervous system tumors, such as neutron or neon therapy, the safety of pion therapy, which is of intermediate LET, has been reaffirmed. However, this study has demonstrated no therapeutic gain for pion therapy of glioblastoma

  7. Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model.

    Science.gov (United States)

    Veulemans, Verena; Mollus, Sabine; Saalbach, Axel; Pietsch, Max; Hellhammer, Katharina; Zeus, Tobias; Westenfeld, Ralf; Weese, Jürgen; Kelm, Malte; Balzer, Jan

    2016-10-26

    To investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR). Rotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT data set was segmented using a 3D heart model. From that the line of perpendicularity curve was obtained that generates a perpendicular view of the aortic annulus according to the right-cusp rule. To evaluate the accuracy of a model-based overlay we compared model- and expert-derived aortic root diameters. For all 57 patients in the RCT cohort diameter measurements were obtained from two independent operators and were compared to the model-based measurements. The inter-observer variability was measured to be in the range of 0°-12.96° of angular C-arm displacement for two independent operators. The model-to-operator agreement was 0°-13.82°. The model-based and expert measurements of aortic root diameters evaluated at the aortic annulus ( r = 0.79, P optimal C-arm configuration, potentially simplifying current clinical workflows before and during TAVR.

  8. Calibration of solar radiation measuring instruments. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bahm, R J; Nakos, J C

    1979-11-01

    A review of solar radiation measurement of instruments and some types of errors is given; and procedures for calibrating solar radiation measuring instruments are detailed. An appendix contains a description of various agencies who perform calibration of solar instruments and a description of the methods they used at the time this report was prepared. (WHK)

  9. Robotic arm

    Science.gov (United States)

    Kwech, Horst

    1989-04-18

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel.

  10. Measurements of neutron radiation in aircraft

    International Nuclear Information System (INIS)

    Vukovic, B.; Poje, M.; Varga, M.; Radolic, V.; Miklavcic, I.; Faj, D.; Stanic, D.; Planinic, J.

    2010-01-01

    Radiation environment is a complex mixture of charged particles of the solar and galactic origin, as well as of secondary particles created in an interaction of galactic cosmic particles with the nuclei of the Earth's atmosphere. A radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. In order to measure a neutron component of the cosmic radiation, we investigated a few combinations of a track etch detector (CR-39, LR-115) with a plastic converter or boron foil. Detector calibration was performed on neutrons coming from the nuclear reactor, as well as in the CERN-EU high-energy Reference Field (CERF) facility. From November 2007 to September 2008, the neutron dose equivalent was measured by the track detectors during five aircraft flights, in the north geographical latitude from 21 o to 58 o ; the respective average dose rate, determined by using the D-4 detector (CR-39/B), was H n =5.9 μSv/h. The photon dose rate, measured by the electronic dosimeter RAD-60 SE, had the average value of H f =1.4 μSv/h.

  11. Measurements of neutron radiation in aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B.; Poje, M.; Varga, M.; Radolic, V.; Miklavcic, I. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Faj, D. [Clinical Hospital Osijek (Croatia); Stanic, D. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Planinic, J., E-mail: planinic@ffos.h [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia)

    2010-12-15

    Radiation environment is a complex mixture of charged particles of the solar and galactic origin, as well as of secondary particles created in an interaction of galactic cosmic particles with the nuclei of the Earth's atmosphere. A radiation field at aircraft altitude consists of different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. In order to measure a neutron component of the cosmic radiation, we investigated a few combinations of a track etch detector (CR-39, LR-115) with a plastic converter or boron foil. Detector calibration was performed on neutrons coming from the nuclear reactor, as well as in the CERN-EU high-energy Reference Field (CERF) facility. From November 2007 to September 2008, the neutron dose equivalent was measured by the track detectors during five aircraft flights, in the north geographical latitude from 21{sup o} to 58{sup o}; the respective average dose rate, determined by using the D-4 detector (CR-39/B), was H{sub n}=5.9 {mu}Sv/h. The photon dose rate, measured by the electronic dosimeter RAD-60 SE, had the average value of H{sub f}=1.4 {mu}Sv/h.

  12. Measurement of indoor background ionizing radiation in some ...

    African Journals Online (AJOL)

    Certain types of building materials are known to be radioactive. Exposure to indoor ionizing radiation like exposure to any other type of ionizing radiation results in critical health challenges. Measurement of the background ionizing radiation profile within the Chemistry Research Laboratory and Physics Laboratory III all of ...

  13. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  14. Optical fibers and their applications for radiation measurements

    International Nuclear Information System (INIS)

    Kakuta, Tsunemi

    1998-01-01

    As a new method of radiation measurements, several optical methods using optical fiber sensors have been developed. One is the application of 'radio-luminescence' from the optical fiber itself such as plastic scintillating fibers. Other researches are made to develop the 'combined-sensors' by combination of optical fibers and scintillating materials. Using the time domain method of optical fiber sensors, the profile of radiation distribution along the optical fiber can be easily determined. A multi-parameter sensing system for measurement of radiation, temperature, stress, etc, are also expected using these optical fiber sensors. (author)

  15. ARM West Antarctic Radiation Experiment (AWARE) Science Plan

    Energy Technology Data Exchange (ETDEWEB)

    Lubin, D [National Science Foundation; Bromwich, DH [Ohio State University; Russell, LM [Scripps Institution of Oceanography; Verlinde, J [The Pennsylvania State University; Vogelmann, AM [Brookhaven National Laboratory

    2015-10-01

    West Antarctica is one of the most rapidly warming regions on Earth, and this warming is closely connected with global sea level rise. The discovery of rapid climate change on the West Antarctic Ice Sheet (WAIS) has challenged previous explanations of Antarctic climate change that focused on strengthening of circumpolar westerlies in response to the positive polarity trend in the Southern Annular Mode. West Antarctic warming does not yet have a comprehensive explanation: dynamical mechanisms may vary from one season to the next, and these mechanisms very likely involve complex teleconnections with subtropical and tropical latitudes. The prime motivation for this proposal is that there has been no substantial atmospheric science or climatological field work on West Antarctica since the 1957 International Geophysical Year and that research continued for only a few years. Direct meteorological information on the WAIS has been limited to a few automatic weather stations for several decades, yet satellite imagery and meteorological reanalyses indicate that West Antarctica is highly susceptible to advection of warm and moist maritime air with related cloud cover, depending on the location and strength of low pressure cells in the Amundsen, Ross, and Bellingshausen Seas. There is a need to quantify the role of these changing air masses on the surface energy balance, including all surface energy components and cloud-radiative forcing. More generally, global climate model simulations are known to perform poorly over the Antarctic and Southern Oceans, and the marked scarcity of cloud information at southern high latitudes has so far inhibited significant progress. Fortunately, McMurdo Station, where the Atmospheric Radiation Measurement Facility’s (ARM’s) most advanced cloud and aerosol instrumentation is situated, has a meteorological relationship with the WAIS via circulation patterns in the Ross and Amundsen Seas. We can therefore gather sophisticated data with cloud

  16. Bunch Length Measurements using Coherent Radiation

    CERN Document Server

    Ischebeck, Rasmus; Barnes, Christopher; Blumenfeld, Ian; Clayton, Chris; Decker, Franz Josef; Deng, Suzhi; Hogan, Mark; Huang Cheng Kun; Iverson, Richard; Johnson, Devon K; Krejcik, Patrick; Lu, Wei; Marsh, Kenneth; Oz, Erdem; Siemann, Robert; Walz, Dieter

    2005-01-01

    The accelerating field that can be obtained in a beam-driven plasma wakefield accelerator depends on the current of the electron beam that excites the wake. In the E-167 experiment, a peak current above 10kA will be delivered at a particle energy of 28GeV. The bunch has a length of a few ten micrometers and several methods are used to measure its longitudinal profile. Among these, autocorrelation of coherent transition radiation (CTR) is employed. The beam passes a thin metallic foil, where it emits transition radiation. For wavelengths greater than the bunch length, this transition radiation is emitted coherently. This amplifies the long-wavelength part of the spectrum. A scanning Michelson interferometer is used to autocorrelate the CTR. However, this method requires the contribution of many bunches to build an autocorrelation trace. The measurement is influenced by the transmission characteristics of the vacuum window and beam splitter. We present here an analysis of materials, as well as possible layouts ...

  17. Robotic arm

    International Nuclear Information System (INIS)

    Kwech, H.

    1989-01-01

    A robotic arm positionable within a nuclear vessel by access through a small diameter opening and having a mounting tube supported within the vessel and mounting a plurality of arm sections for movement lengthwise of the mounting tube as well as for movement out of a window provided in the wall of the mounting tube is disclosed. An end effector, such as a grinding head or welding element, at an operating end of the robotic arm, can be located and operated within the nuclear vessel through movement derived from six different axes of motion provided by mounting and drive connections between arm sections of the robotic arm. The movements are achieved by operation of remotely-controllable servo motors, all of which are mounted at a control end of the robotic arm to be outside the nuclear vessel. 23 figs

  18. Phantoms for Radiation Measurements of Mobile Phones

    DEFF Research Database (Denmark)

    Pedersen, Gert Frølund

    2001-01-01

    Measurements of radiation efficiency for a handheld phone equipped with a patch and a helical antenna operated near the human user have been performed. Both measurements include a simple head plus hand phantom and live persons are considered. The position of the hand on the phone is found...... to be the main reason for the large variation in radiation efficiency among persons. The tilt angle of the phone and the distance between the head and phone only play a minor role...

  19. Sensory-Feedback Exoskeletal Arm Controller

    Science.gov (United States)

    An, Bin; Massie, Thomas H.; Vayner, Vladimir

    2004-01-01

    between the exoskeletal mechanism and the shoulder. 4. The fourth DOF is that of flexion and extension of the elbow. The reflected torque for this DOF is provided by motor 4 and drum 4, which are mounted on a bracket that can slide longitudinally by a pin-and-slot engagement with the upper-arm cuff to compensate for slight variations in the position of the kinematic center of the elbow. Attached to drum 4 is an adapter plate to which is attached a CRCM for the lower arm. 5. The lower-arm CRCM implements the fifth DOF, which is the twist of the forearm about its longitudinal axis. Motor 5 provides the reflected torque for this DOF by driving the lower-arm cuff. A rod transmits twist and torsion between the lower-arm cuff and the hand cuff. With this system, the motion of the wearer s joints and the reflected torques applied to these joints can be measured and controlled in a relatively simple manner. This is because the anthropomorphic design of the mechanism imitates the kinematics of the human arm, eliminating the need for kinematic conversion of joint-torque and joint-angle data.

  20. Radiated power measurement with AXUV photodiodes in EAST tokamak

    International Nuclear Information System (INIS)

    Duan Yanmin; Hu Liqun; Du Wei; Mao Songtao; Chen Kaiyun; Zhang Jizhong

    2013-01-01

    The fast bolometer diagnostic system for absolute radiated power measurement on EAST tokamak is introduced, which is based on the absolute extreme ultraviolet (AXUV) photodiodes. The relative calibration of AXUV detectors is carried out using X-ray tube and standard luminance source in order to evaluate the sensitivity degradation caused by cumulative radiation damage during experiments. The calibration result shows a 23% sensitivity decrease in the X-ray range for the detector suffering ∼27000 discharges, but the sensitivity for the visible light changes little. The radiated power measured by AXUV photodiodes is compared with that measured by resistive bolometer. The total radiated power in main plasma deduced from AXUV detector is lower a factor of 1∼4 than that deduced from resistive bolometer. Some typical measurement results are also shown in this article. (author)

  1. A new way to measure mid-upper-arm circumference in African villages

    Directory of Open Access Journals (Sweden)

    Gregor Pollach

    2014-06-01

    Full Text Available In 2011 we published a study on how to detect the threshold for malnutrition in children, simply using their own hands and without any technical tool. The fight against malnutrition can only be reached when its measurements involve every single child, almost continuously, in the affected villages. In this paper we try to show that, thanks to our method, it is possible to use mid-upper-arm-circumference as a measurement for malnutrition in children, discriminating between severe and moderate malnutrition and providing the basis for the decision on whether to admit a child to a nutritional rehabilitation unit or not. We trained 63 participants in four groups (Group 1: doctors and clinical officers; Group 2: nurses and students; as Group 3 we defined the 20 best participants and Group 4 consisted of 10 more intensely trained participants to measure the circumference of 9 different artificial arms (between 9 and 13 cm using their own fingers and hands. The training was short and consisted of an introduction of 5 min, a first training phase of 10-15 min, a test, the critical discussion of the results, a second training phase of 5 min and a final test. We found that 95.3% of participants in the general group and 97.9% in the intensely trained group have identified the severely malnourished child; 87.3% in the general group and 91.9% in the intensely trained group have additionally identified the moderately malnourished child. Both groups haven’t admitted the well nourished child to a therapeutic feeding program retaining their resources. The third group reached without any additional training the results in the above categories. A subsequent discussion with the participants on the influence of procurement, maintenance and pricing of our tool, found our method much less vulnerable than others. We conclude that this method should be considered as a future training in the villages to detect the trend towards malnutrition early enough.

  2. Measurement of solar energy radiation in Abu Dhabi, UAE

    Energy Technology Data Exchange (ETDEWEB)

    Islam, M.D.; Kubo, I.; Ohadi, M.; Alili, A.A. [Department of Mechanical Engineering, The Petroleum Institute, Abu Dhabi, P.O. Box 2533 (United Arab Emirates)

    2009-04-15

    This paper presents data on measurement of actual solar radiation in Abu Dhabi (24.43 N, 54.45 E). Global solar radiation and surface temperatures were measured and analyzed for one complete year. High resolution, real-time solar radiation and other meteorological data were collected and processed. Daily and monthly average solar radiation values were calculated from the one-minute average recorded values. The highest daily and monthly mean solar radiation values were 369 and 290 W/m{sup 2}, respectively. The highest one-minute average daily solar radiation was 1041 W/m{sup 2}. Yearly average daily energy input was 18.48 MJ/m{sup 2}/day. Besides the global solar radiation, the daily and monthly average clearness indexes along with temperature variations are discussed. When possible, global solar energy radiation and some meteorological data are compared with corresponding data in other Arab state capitals. The data collected indicate that Abu Dhabi has a strong potential for solar energy capture. (author)

  3. Measurement of solar energy radiation in Abu Dhabi, UAE

    International Nuclear Information System (INIS)

    Islam, M.D.; Kubo, I.; Ohadi, M.; Alili, A.A.

    2009-01-01

    This paper presents data on measurement of actual solar radiation in Abu Dhabi (24.43 deg. N, 54.45 deg. E). Global solar radiation and surface temperatures were measured and analyzed for one complete year. High resolution, real-time solar radiation and other meteorological data were collected and processed. Daily and monthly average solar radiation values were calculated from the one-minute average recorded values. The highest daily and monthly mean solar radiation values were 369 and 290 W/m 2 , respectively. The highest one-minute average daily solar radiation was 1041 W/m 2 . Yearly average daily energy input was 18.48 MJ/m 2 /day. Besides the global solar radiation, the daily and monthly average clearness indexes along with temperature variations are discussed. When possible, global solar energy radiation and some meteorological data are compared with corresponding data in other Arab state capitals. The data collected indicate that Abu Dhabi has a strong potential for solar energy capture

  4. Metrology of ionizing radiations and environmental measurements

    International Nuclear Information System (INIS)

    Nourreddine, Abdel-Mjid

    2008-01-01

    The subject of radiation protection covers all measurements taken by the authorities to ensure protection of the population and its environment against the harmful effects of ionizing radiation. Dosimetry occupies an important place in this field, because it makes it possible to consider and to quantify the risk of using radiations in accordance with the prescribed limits. In this course, we will review the fundamental concepts used in the metrology and dosimetry of ionizing radiations. After classification of ionizing radiations according to their interactions with biological matter, we will present the various quantities and units brought into play and in particular the new operational quantities that are good estimators raising protection standards. They are directly connected to the annual limits of effective dose and of equivalent dose defined in the French regulation relating to the protection of the population and of workers against ionizing radiations. The average natural exposure of the population in France varies between 2 to 2.5 mSv per year, depending on geographic location. It comes principally from three sources: cosmic radiation, radioactive elements contained in the ground and radioactive elements that we absorb when breathing or eating. Radon, which is a naturally occurring radioactive gas, is a public health risk and represents 30% of the exposure. Finally, we will give some applications of dosimetry and environmental measurements developed recently at RaMsEs/IPHC laboratory of Strasbourg. (author)

  5. Integration of gamma measuring equipment into an Agusta A109BA helicopter of the Belgian Armed Forces for use in emergency situations

    International Nuclear Information System (INIS)

    Paridaens, J.

    2007-01-01

    In case of a nuclear emergency, accidental releases of radioactive material might cause large scale environmental contamination. After the emergency has been brought under control, and the radioactive releases have settled on the ground, it is essential to map as quickly as possible the extent of the contaminated area and to evaluate the severity of the contamination. Airborne gamma measurements are known to be an effective means for quickly and safely mapping and evaluating large scale contaminations of gamma-emitting radio nuclides. We wanted to integrate gamma measuring equipment, based on a NaI detector, into an Agusta A109BA helicopter of the Belgian armed forces. This was done within the framework of ''Aid to the Nation'', a special program developed by the Belgian Armed Forces for facilitating cooperation between the armed forces and civilian organisations, for projects that are to the benefit of the Belgian Nation. Working in this framework, we also want to develop the necessary procedures that will allow quick and efficient deployment of the measuring capability in case of an emergency

  6. The optical properties of equatorial cirrus in the pilot radiation observation experiment

    Energy Technology Data Exchange (ETDEWEB)

    Platt, C.M.R.; Young, S.A.; Manson, P.; Patterson, G.R. [CSIRO, Victoria (Australia)] [and others

    1996-04-01

    The development of a sensitive filter radiometer for the Atmospheric Radiation Measurement (ARM) Program has been reported. The aim was to develop a reliable and fast instrument that could be used alongside a lidar to obtain near realtime optical properties of clouds, particularly high ice clouds, as they drifted over an ARM Cloud and Radiation Testbed (CART) site allowing calculation of the radiation divergence in the atmosphere over the site. Obtaining cloud optical properties by the lidar/radiometer, or LIRAD, method was described by Platt et al.; the latter paper also describes a year`s data on mid-latitude cirrus. The optical properties of equatorial cirrus (i.e., cirrus within a few degrees of the equator) have hardly been studied at all. The same is true of tropical cirrus, although a few observations have been reported by Davis and Platt et al.This paper describes obersvations performed on cirrus clouds, analysis methods used, and results.

  7. Midupper Arm Circumference Outperforms Weight-Based Measures of Nutritional Status in Children with Diarrhea12

    Science.gov (United States)

    Modi, Payal; Nasrin, Sabiha; Hawes, Meagan; Glavis-Bloom, Justin; Alam, Nur H; Hossain, M Iqbal; Levine, Adam C

    2015-01-01

    Background: Undernutrition contributes to 45% of all deaths in children children with diarrhea and possible dehydration. Objective: This study assessed the validity of different measures of undernutrition in children with diarrhea. Methods: A prospective cohort study was conducted at an urban hospital in Bangladesh. Children children for screening, of which 1025 were eligible, 850 were enrolled, and 721 had complete data for analysis. Anthropometric measurements, including weight-for-age z score (WAZ), weight-for-length z score (WLZ), midupper arm circumference (MUAC), and midupper arm circumference z score (MUACZ), were calculated pre- and posthydration in all patients. Measurements were evaluated for their ability to correctly identify undernutrition in children with varying degrees of dehydration. Results: Of the 721 patients with full data for analysis, the median percent dehydration was 4%. Of the 4 measures evaluated, MUAC and MUACZ demonstrated 92–94% agreement pre- and posthydration compared with 69–76% for WAZ and WLZ. Although each 1% change in hydration status was found to change weight-for-age by 0.0895 z scores and weight-for-length by 0.1304 z scores, MUAC and MUACZ were not significantly affected by dehydration status. Weight-based measures misclassified 12% of children with severe underweight and 14% with severe acute malnutrition (SAM) compared with only 1–2% for MUAC and MUACZ. Conclusions: MUAC and MUACZ were the most accurate predictors of undernutrition in children with diarrhea. WAZ and WLZ were significantly affected by dehydration status, leading to the misdiagnosis of many patients on arrival with severe underweight and SAM. This trial was registered at clinicaltrials.gov as NCT02007733. PMID:25972523

  8. Monitoring the radiation dose to a multiprogrammable pacemaker during radical radiation therapy: A case report

    International Nuclear Information System (INIS)

    Muller-Runkel, R.; Orsolini, G.; Kalokhe, U.P.

    1990-01-01

    Multiprogrammable pacemakers, using complimentary metaloxide semiconductor (CMOS) circuitry, may fail during radiation therapy. We report about a patient who received 6,400 cGy for unresectable carcinoma of the left lung. In supine treatment position, arms raised above the head, the pacemaker was outside the treated area by a margin of at least 1 cm, shielded by cerrobend blocking mounted on a tray. From thermoluminescent dosimeter (TLD) measurements, we estimate that the pacemaker received 620 cGy in scatter doses. Its function was monitored before, during, and after completion of radiation therapy. The pacemaker was functioning normally until the patient's death 5 months after completion of treatment. The relevant electrocardiograms (ECGs) are presented

  9. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  10. Dose measurements in pulsed radiation fields with commercially available measuring components

    International Nuclear Information System (INIS)

    Friedrich, Sabrina; Hupe, Oliver

    2016-01-01

    Dose measurements in pulsed radiation fields with dosemeters using the counting technique are known to be inappropriate. Therefore, there is a demand for a portable device able to measure the dose in pulsed radiation fields. As a detector, ionisation chambers seem to be a good alternative. In particular, using a secondary standard ionisation chamber in combination with a reliable charge-measuring system would be a good solution. The Physikalisch-Technische Bundesanstalt (PTB) uses secondary standard ionisation chambers in combination with PTB-made measuring electronics for dose measurements at its reference fields. However, for general use, this equipment is too complex. For measurements on-site, a mobile special electronic system [Hupe, O. and Ankerhold, U. Determination of ambient and personal dose equivalent for personnel and cargo security screening. Radiat. Prot. Dosim. 121(4), 429-437 (2006)] has been used successfully. Still, for general use, there is a need for a much simpler but a just as good solution. A measuring instrument with very good energy dependence for H*(10) is the secondary standard ionisation chamber HS01. An easy-to-use and commercially available electrometer for measuring the generated charges is the UNIDOS by PTW Freiburg. Depending on the expected dose values, the ionisation chamber used can be selected. In addition, measurements have been performed by using commercially available area dosemeters, e.g. the Mini SmartION 2120S by Thermo Scientific, using an ionisation chamber and the Szintomat 6134 A/H by Automess, using a scintillation detector. (authors)

  11. Simultaneous Authentication and Certification of Arms-Control Measurement Systems

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Hauck, Danielle K.; Thron, Jonathan L.

    2012-01-01

    Most arms-control-treaty-monitoring scenarios involve a host party that makes a declaration regarding its nuclear material or items and a monitoring party that verifies that declaration. A verification system developed for such a use needs to be trusted by both parties. The first concern, primarily from the host party's point of view, is that any sensitive information that is collected must be protected without interfering in the efficient operation of the facility being monitored. This concern is addressed in what can be termed a 'certification' process. The second concern, of particular interest to the monitoring party, is that it must be possible to confirm the veracity of both the measurement system and the data produced by this measurement system. The monitoring party addresses these issues during an 'authentication' process. Addressing either one of these concerns independently is relatively straightforward. However, it is more difficult to simultaneously satisfy host party certification concerns and monitoring party authentication concerns. Typically, both parties will want the final access to the measurement system. We will describe an alternative approach that allows both parties to gain confidence simultaneously. This approach starts with (1) joint development of the measurement system followed by (2) host certification of several copies of the system and (3) random selection by the inspecting party of one copy to be use during the monitoring visit and one (or more) copy(s) to be returned to the inspecting party's facilities for (4) further hardware authentication; any remaining copies are stored under joint seal for use as spares. Following this process, the parties will jointly (5) perform functional testing on the selected measurement system and then (6) use this system during the monitoring visit. Steps (1) and (2) assure the host party as to the certification of whichever system is eventually used in the monitoring visit. Steps (1), (3), (4), and (5

  12. Simultaneous Authentication and Certification of Arms-Control Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    MacArthur, Duncan W. [Los Alamos National Laboratory; Hauck, Danielle K. [Los Alamos National Laboratory; Thron, Jonathan L. [Los Alamos National Laboratory

    2012-07-09

    Most arms-control-treaty-monitoring scenarios involve a host party that makes a declaration regarding its nuclear material or items and a monitoring party that verifies that declaration. A verification system developed for such a use needs to be trusted by both parties. The first concern, primarily from the host party's point of view, is that any sensitive information that is collected must be protected without interfering in the efficient operation of the facility being monitored. This concern is addressed in what can be termed a 'certification' process. The second concern, of particular interest to the monitoring party, is that it must be possible to confirm the veracity of both the measurement system and the data produced by this measurement system. The monitoring party addresses these issues during an 'authentication' process. Addressing either one of these concerns independently is relatively straightforward. However, it is more difficult to simultaneously satisfy host party certification concerns and monitoring party authentication concerns. Typically, both parties will want the final access to the measurement system. We will describe an alternative approach that allows both parties to gain confidence simultaneously. This approach starts with (1) joint development of the measurement system followed by (2) host certification of several copies of the system and (3) random selection by the inspecting party of one copy to be use during the monitoring visit and one (or more) copy(s) to be returned to the inspecting party's facilities for (4) further hardware authentication; any remaining copies are stored under joint seal for use as spares. Following this process, the parties will jointly (5) perform functional testing on the selected measurement system and then (6) use this system during the monitoring visit. Steps (1) and (2) assure the host party as to the certification of whichever system is eventually used in the monitoring visit

  13. A low-noise measurement system for scanning thermal microscopy resistive nanoprobes based on a transformer ratio-arm bridge

    Science.gov (United States)

    Świątkowski, Michał; Wojtuś, Arkadiusz; Wielgoszewski, Grzegorz; Rudek, Maciej; Piasecki, Tomasz; Jóźwiak, Grzegorz; Gotszalk, Teodor

    2018-04-01

    Atomic force microscopy (AFM) is a widely used technology for the investigation and characterization of nanomaterials. Its functionality can be easily expanded by applying dedicated extension modules, which can measure the electrical conductivity or temperature of a sample. In this paper, we introduce a transformer ratio-arm bridge setup dedicated to AFM-based thermal imaging. One of the key features of the thermal module is the use of a low-power driving signal that prevents undesirable tip heating during resistance measurement, while the other is the sensor location in a ratio-arm transformer bridge working in the audio frequency range and ensuring galvanic isolation of the tip, enabling contact-mode scanning of electronic circuits. The proposed expansion module is compact and it can be integrated onto the AFM head close to the cantilever. The calibration process and the resolution of 11 mK of the proposed setup are shown.

  14. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  15. Errors in measuring absorbed radiation and computing crop radiation use efficiency

    International Nuclear Information System (INIS)

    Gallo, K.P.; Daughtry, C.S.T.; Wiegand, C.L.

    1993-01-01

    Radiation use efficiency (RUE) is often a crucial component of crop growth models that relate dry matter production to energy received by the crop. RUE is a ratio that has units g J -1 , if defined as phytomass per unit of energy received, and units J J -1 , if defined as the energy content of phytomass per unit of energy received. Both the numerator and denominator in computation of RUE can vary with experimental assumptions and methodologies. The objectives of this study were to examine the effect that different methods of measuring the numerator and denominator have on the RUE of corn (Zea mays L.) and to illustrate this variation with experimental data. Computational methods examined included (i) direct measurements of the fraction of photosynthetically active radiation absorbed (f A ), (ii) estimates of f A derived from leaf area index (LAI), and (iii) estimates of f A derived from spectral vegetation indices. Direct measurements of absorbed PAR from planting to physiological maturity of corn were consistently greater than the indirect estimates based on green LAI or the spectral vegetation indices. Consequently, the RUE calculated using directly measured absorbed PAR was lower than the RUE calculated using the indirect measures of absorbed PAR. For crops that contain senesced vegetation, green LAI and the spectral vegetation indices provide appropriate estimates of the fraction of PAR absorbed by a crop canopy and, thus, accurate estimates of crop radiation use efficiency

  16. Arms Control and nonproliferation technologies: Technology options and associated measures for monitoring a Comprehensive Test Ban, Second quarter

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Leslie A.

    1994-01-01

    This newsletter contains reprinted papers discussing technology options and associated measures for monitoring a Comprehensive Test Ban Treaty (CTBT). These papers were presented to the Conference on Disarmament (CD) in May and June 1994. An interagency Verification Monitoring Task Force developed the papers. The task force included participants from the Arms Control and Disarmament Agency, the Department of Defense, the Department of Energy, the Intelligence Community, the Department of Interior, and the Department of State. The purpose of this edition of Arms Control and Nonproliferation Technologies is to share these papers with the broad base of stakeholders in a CTBT and to facilitate future technology discussions. The papers in the first group discuss possible technology options for monitoring a CTBT in all environments (underground, underwater, atmosphere, and space). These technologies, along with on-site inspections, would facilitate CTBT monitoring by treaty participants. The papers in the second group present possible associated measures, e.g., information exchanges and transparency measures, that would build confidence among states participating in a CTBT.

  17. Survey by measurement of urban environmental radiation, 1

    International Nuclear Information System (INIS)

    Inokoshi, Yukio; Kitahara, Akiharu; Suzuki, Takashi; Sugiura, Shiroharu; Shindo, Kotaro

    1984-01-01

    In the evaluation of the effect of radiation on the population of Tokyo Metropolis, it is necessary to know the external exposure due to natural radiation. Radiation dose rate has been measured on the ground (parks, etc.), paved roads (sidewalks), buildings, and transportation facilities (subways). The average values of cosmic ray and ground radiation were 8.8 x 10 -10 C/kg.h and 6.5 x 10 -10 C/kg.h, respectively. The radiation dose rate on roads differed largely with the structural materials, thickness, etc. The radiation in wooden buildings was almost similar to surrounding natural radiation. In high-rise buildings, there was not much difference from floor to floor. The natural radiation in subways depends largely on the depth. (Mori, K.)

  18. Changes in arm-hand function and arm-hand skill performance in patients after stroke during and after rehabilitation.

    Science.gov (United States)

    Franck, Johan Anton; Smeets, Rob Johannes Elise Marie; Seelen, Henk Alexander Maria

    2017-01-01

    Arm-hand rehabilitation programs applied in stroke rehabilitation frequently target specific populations and thus are less applicable in heterogeneous patient populations. Besides, changes in arm-hand function (AHF) and arm-hand skill performance (AHSP) during and after a specific and well-described rehabilitation treatment are often not well evaluated. This single-armed prospective cohort study featured three subgroups of stroke patients with either a severely, moderately or mildly impaired AHF. Rehabilitation treatment consisted of a Concise_Arm_and_hand_ Rehabilitation_Approach_in_Stroke (CARAS). Measurements at function and activity level were performed at admission, clinical discharge, 3, 6, 9 and 12 months after clinical discharge. Eighty-nine stroke patients (M/F:63/23; mean age:57.6yr (+/-10.6); post-stroke time:29.8 days (+/-20.1)) participated. All patients improved on AHF and arm-hand capacity during and after rehabilitation, except on grip strength in the severely affected subgroup. Largest gains occurred in patients with a moderately affected AHF. As to self-perceived AHSP, on average, all subgroups improved over time. A small percentage of patients declined regarding self-perceived AHSP post-rehabilitation. A majority of stroke patients across the whole arm-hand impairment severity spectrum significantly improved on AHF, arm-hand capacity and self-perceived AHSP. These were maintained up to one year post-rehabilitation. Results may serve as a control condition in future studies.

  19. Measuring element for the detection and determination of radiation doses of gamma radiation and neutrons

    International Nuclear Information System (INIS)

    Jahn, W.; Piesch, E.

    1975-01-01

    A measuring element detects and proves both gamma and neutron radiation. The element includes a photoluminescent material which stores gamma radiation and particles of arsenic and phosphorus embedded in the photoluminescent material for detecting neutron radiation. (U.S.)

  20. CHARACTERISTICS OF SPIRAL ARMS IN LATE-TYPE GALAXIES

    International Nuclear Information System (INIS)

    Honig, Z. N.; Reid, M. J.

    2015-01-01

    We have measured the positions of large numbers of H II regions in four nearly face-on, late-type, spiral galaxies: NGC 628 (M74), NGC 1232, NGC 3184, and NGC 5194 (M51). Fitting log-periodic spiral models to segments of each arm yields local estimates of spiral pitch angle and arm width. While pitch angles vary considerably along individual arms, among arms within a galaxy, and among galaxies, we find no systematic trend with galactocentric distance. We estimate the widths of the arm segments from the scatter in the distances of the H II regions from the spiral model. All major arms in these galaxies show spiral arm width increasing with distance from the galactic center, similar to the trend seen in the Milky Way. However, in the outermost parts of the galaxies, where massive star formation declines, some arms reverse this trend and narrow. We find that spiral arms often appear to be composed of segments of ∼5 kpc length, which join to form kinks and abrupt changes in pitch angle and arm width; these characteristics are consistent with properties seen in the large N-body simulations of D'Onghia et al. and others

  1. C-arm guided closed reduction of zygomatic arch fracture

    International Nuclear Information System (INIS)

    Eo, Yoon Ki; Lee, Dong Kun; Kim, Jeong Sam; Jang, Young Il

    1999-01-01

    The zygomatic arch is structurally protruded and is easily fractured. The classic management of zygomatic arch fracture has been mentioned the Keen, Lothrop, Dingman and Alling and threaded K-wire. All of the above methods have advantages and disadvantages. To minimize the disadvantages, we performed threaded K-wire for the first time using C-arm image intensifier. The subjects were 16 patients with Knight North group II (Zygomatic arch fracture). Among them the C-arm was used in 12 patients and the operator used sensitivity general method in 4 patients and confirmed the operation by mobile X-ray equipment. In conclusion, both groups were satisfied surgically and cosmetically. Using the C-arm, actual image at the time operation was clear and satisfied, the surrounding tissue damage was minimized and at was more accurately completed. The operation time was shortened by 30 to 60 minutes proving it to be an efficient method. We suggest though that further studies be needed to evaluate the radiation effect on these patients

  2. Aircrew radiation exposure: sources-risks-measurement

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1994-05-01

    A short review is given on the actual aircrew exposure and its sources. The resulting risks for harmful effects to the health and discuss methods for in-flight measurements of exposure is evaluated. An idea for a fairly simple and economic approach to a practical, airborne active dosimeter for the assessment of individual crew exposure is presented. The exposure of civil aircrew to cosmic radiation, should not be considered a tremendous risk to the health, there is no reason for panic. However, being significantly higher than the average exposure to radiation workers, it can certainly not be neglected. As recommended by ICRP, aircrew exposure has to be considered occupational radiation exposure and aircrews are certainly entitled to the same degree of protection, as other ground-based radiation workers have obtained by law, since long time. (author)

  3. Measuring the greenhouse effect and radiative forcing through the atmosphere

    Science.gov (United States)

    Philipona, Rolf; Kräuchi, Andreas; Brocard, Emmanuel

    2013-04-01

    In spite of a large body of existing measurements of incoming shortwave solar radiation and outgoing longwave terrestrial radiation at the Earth's surface and at the top of the atmosphere, there are few observations documenting how radiation profiles change through the atmosphere - information that is necessary to fully quantify the greenhouse effect of the Earth's atmosphere. Using weather balloons and specific radiometer equipped radiosondes, we continuously measured shortwave and longwave radiation fluxes from the surface of the Earth up to altitudes of 35 kilometers in the upper stratosphere. Comparing radiation profiles from night measurements with different amounts of water vapor, we show evidence of large greenhouse forcing. We show, that under cloud free conditions, water vapor increases with Clausius-Clapeyron ( 7% / K), and longwave downward radiation at the surface increases by 8 Watts per square meter per Kelvin. The longwave net radiation however, shows a positive increase (downward) of 2.4 Watts per square meter and Kelvin at the surface, which decreases with height and shows a similar but negative increase (upward) at the tropopause. Hence, increased tropospheric water vapor increases longwave net radiation towards the ground and towards space, and produces a heating of 0.42 Kelvin per Watt per square meter at the surface. References: Philipona et al., 2012: Solar and thermal radiation profiles and radiative forcing measured through the atmosphere. Geophys. Res. Lett., 39, L13806, doi: 10.1029/2012GL052087.

  4. Radiation transmission pipe thickness measurement system

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  5. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  6. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  7. USA's gift aids radiation measurement

    International Nuclear Information System (INIS)

    1970-01-01

    On 8 December 1969, the anniversary of President Eisenhower's speech which led to the foundation of the Agency, the United States of America handed over a $25 000 gift which will assist considerably the promotion of world-wide standardization in the measurement of radiation. (author)

  8. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    Energy Technology Data Exchange (ETDEWEB)

    Vallée, Jacques P., E-mail: jacques.vallee@nrc-cnrc.gc.ca [National Research Council Canada, National Science Infrastructure portfolio, Herzberg Astronomy and Astrophysics, 5071 West Saanich Road, Victoria, B.C., V9E 2E7 (Canada)

    2014-07-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  9. The spiral arms of the Milky Way: The relative location of each different arm tracer within a typical spiral arm width

    International Nuclear Information System (INIS)

    Vallée, Jacques P.

    2014-01-01

    From the Sun's location in the Galactic disk, different arm tracers (CO, H I, hot dust, etc.) have been employed to locate a tangent to each spiral arm. Using all various and different observed spiral arm tracers (as published elsewhere), we embark on a new goal, namely the statistical analysis of these published data (data mining) to statistically compute the mean location of each spiral arm tracer. We show for a typical arm cross-cut, a separation of 400 pc between the mid-arm and the dust lane (at the inner edge of the arm, toward the Galactic center). Are some arms major and others minor? Separating arms into two sets, as suggested by some, we find the same arm widths between the two sets. Our interpretation is that we live in a multiple (four-arm) spiral (logarithmic) pattern (around a pitch angle of 12°) for the stars and gas in the Milky Way, with a sizable interarm separation (around 3 kpc) at the Sun's location and the same arm width for each arm (near 400 pc from mid-arm to dust lane).

  10. A comparison of radiometric fluxes influenced by parameterization cirrus clouds with observed fluxes at the Southern Great Plains (SGP) cloud and radiation testbed (CART) site

    Energy Technology Data Exchange (ETDEWEB)

    Mace, G.G.; Ackerman, T.P.; George, A.T. [Penn State Univ., University Park, PA (United States)

    1996-04-01

    The data from the Atmospheric Radiation Measurement (ARM) Program`s Southern Great plains Site (SCP) is a valuable resource. We have developed an operational data processing and analysis methodology that allows us to examine continuously the influence of clouds on the radiation field and to test new and existing cloud and radiation parameterizations.

  11. Measurement of Galactic Logarithmic Spiral Arm Pitch Angle Using Two-Dimensional Fast Fourier Transform Decomposition

    OpenAIRE

    Davis, Benjamin L.; Berrier, Joel C.; Shields, Douglas W.; Kennefick, Julia; Kennefick, Daniel; Seigar, Marc S.; Lacy, Claud H. S.; Puerari, Ivânio

    2012-01-01

    A logarithmic spiral is a prominent feature appearing in a majority of observed galaxies. This feature has long been associated with the traditional Hubble classification scheme, but historical quotes of pitch angle of spiral galaxies have been almost exclusively qualitative. We have developed a methodology, utilizing two-dimensional fast Fourier transformations of images of spiral galaxies, in order to isolate and measure the pitch angles of their spiral arms. Our technique provides a quanti...

  12. Radiological emergency: road map for radiation accident victim transport

    International Nuclear Information System (INIS)

    Costa, V.S.G.; Alcantara, Y.P.; Lima, C.M.A.; Silva, F. C. A. da

    2017-01-01

    During a radiological or nuclear emergency, a number of necessary actions are taken, both within the radiation protection of individuals and the environment, involving many institutions and highly specialized personnel. Among them it is possible to emphasize the air transportation of radiation accident victims.The procedures and measures for the safe transport of these radiation accident victims are generally the responsibility of the armed forces, specifically the Aeronautics, with the action denominated 'Aeromedical Military Evacuation of Radiation Accident Victims'. The experience with the Radiological Accident of Goiânia demonstrated the importance of adequate preparation and response during a radiological emergency and the need for procedures and measures with regard to the transport of radiation victims are clearly defined and clearly presented for the effectiveness of the actions. This work presents the necessary actions for the transport of radiation accident victim during a radiological emergency, through the road map technique, which has been widely used in scientific technical area to facilitate understanding and show the way to be followed to reach the proposed objectives

  13. Visits to Australia by nuclear powered or armed vessels: contingency planning for the accidental release of ionizing radiation

    International Nuclear Information System (INIS)

    1989-01-01

    The report refers to the adequacy of current contingency planning by the Australian Federal and Senate authorities to deal with the accidental release of ionizating radiation from visiting nuclear powered or armed vessels in Australian waters and ports. Much of the material was obtained in response to questions put in writing by the Senate Standing Committee to the Department of Defence, ANSTO and others. In addition, the report contains relevant information from Commonwealth documents as well as the Committee findings and recommendations. Issues considered include: types of visiting nuclear powered vessels, accident likelihood and consequences, differences between naval and land-based reactors, safety records. The persons or organizations who made submissions or appeared in all public hearings are listed in the appendixes, along with all visits to Australian ports by nuclear powered warships from 1976 to 1988

  14. Stress analysis for robot arm version 2

    International Nuclear Information System (INIS)

    Anwar Abdul Rahman; Fikri, A.; Salleh, M. S.; Mohd Arif Hamzah; Azraf Azman; Rosli Darmawan; Mohd Rizal Mamat

    2010-01-01

    The design of a robot needs to be analyzed to ensure the specification and requirement by the user is full filled. Therefore, stress analysis has been performed on the robot arm version 2 after its complete fabrication. This paper discusses the result of the analysis and proposed measures to improve the future design of robot arm. (author)

  15. C-arm CT for chemo-embolization of liver tumors

    International Nuclear Information System (INIS)

    Huppert, P.E.; Firlbeck, G.; Meissner, O.A.; Wietholtz, H.

    2009-01-01

    Local efficacy of transarterial chemo-embolization (TACE) is enhanced if selective treatment is performed. Selectivity of TACE mainly depends on vascular anatomy but also on the identification and catheterization of tumor feeding arteries. Correlation of vascular territories and target tumor volume in angiographic projection images is more difficult if tumors are not hypervascularized and contrast of liver parenchyma is inhomogeneous. C-arm CT offers the option of selective perfusion imaging via tumor-feeding arteries. This allows the comparison of perfusion images and baseline cross-sectional imaging to evaluate if tumors are covered completely by local treatment and to change the catheter position if necessary. Furthermore the uptake of embolization material, such as lipiodol can be checked by C-arm CT. In a prospective study of 75 TACE of liver tumors and liver metastases we evaluated the appropriateness of 85 catheter positions ready for delivery by perfusion C-arm CT and compared the diagnostic confidence of angiography and perfusion C-arm CT in terms of judgment of correct catheter position for the planned treatment. Diagnostic confidence was improved by perfusion C-arm CT in 55% of cases and in 11 cases (13%) catheter positions were inappropriate and had to be corrected. The reasons for catheter repositioning were incomplete coverage of the target tumor by perfusion volume (mismatch) in 6 cases, inappropriate perfusion of adjacent liver parenchyma in 2 cases and non-selective tumor perfusion via collateral arteries in 3 cases. C-arm CT allowed sufficient visualization of uptake of lipiodol in all cases evaluated. The diagnostic benefit of C-arm CT increases if tumors are treated more selectively, are not strongly hypervascular, are located centrally and if the enhancement of liver parenchyma is inhomogeneous. C-arm CT causes additional working time and contrast load, which is relatively low compared to angiography. Radiation exposure of 151 μGy per C-arm

  16. Changes in Handset Performance Measures due to Spherical Radiation Pattern Measurement Uncertainty

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    An important characteristic of a mobile handset is its ability to receive and transmit power. One way to characterize the performance of a handset in this respect is to use measurements of the spherical radiation pattern from which the total radiated power (TRP), total isotropic sensitivity (TIS)...... with respect to the environment. Standard deviations up to about 0.5dB and a maximum deviation of about 1.6dB were found....... in the performance measures are investigated for both the GSM-900 and the GSM-1800 band. Despite the deliberately large deviations from the reference position, the changes in TRP and TIS are generally within ±0.5dB with a maximum of about 1.4dB. For the MEG values the results depend on the orientation of the handset...... system that may introduce errors in standardized performance measurements. Radiation patterns of six handsets have been measured while they were mounted at various offsets from the reference position defined by the Cellular Telecommunications & Internet Association (CTIA) certification. The change...

  17. Measurement of TFTR D-T radiation shielding efficiency

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ascione G.; Elwood, S.

    1994-01-01

    High power D-T fusion reactor designs presently exhibit complex geometric and material density configurations. Simulations of the radiation shielding required for safe operation and full compliance with all regulatory requirements must include sufficient margin to accommodate uncertainties in material properties and distributions, uncertainties in the final configurations, and uncertainties in approximations employing the homogenization of complex geometries. Measurements of radiation shielding efficiency performed in a realistic D-T tokamak environment can provide empirical guidance for simulating safe, efficient, and cost effective shielding systems for future high power fusion reactors. In this work, the authors present the results of initial measurements of the TFTR radiation shielding efficiency during high power D-T operations with record neutron yields. The TFTR design objective is to limit the total dose-equivalent at the nearest PPPL property lines from all radiation pathways to 10 mrem per calendar year. Compliance with this design objective over a calendar year requires measurements in the presence of typical site backgrounds of about 80 mrem per year

  18. Space weather effects measured in atmospheric radiation on aircraft

    Science.gov (United States)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Wieman, S. R.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, L. D.; Mertens, C. J.; Xu, X.; Wiltberger, M. J.; Wiley, S.; Teets, E.; Shea, M. A.; Smart, D. F.; Jones, J. B. L.; Crowley, G.; Azeem, S. I.; Halford, A. J.

    2016-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Since 2013 Space Environment Technologies (SET) has been conducting observations of the atmospheric radiation environment at aviation altitudes using a small fleet of six instruments. The objective of this work is to improve radiation risk management in air traffic operations. Under the auspices of the Automated Radiation Measurements for Aerospace Safety (ARMAS) and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) projects our team is making dose rate measurements on multiple aircraft flying global routes. Over 174 ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the radiation environment resulting from Galactic Cosmic Rays (GCRs), Solar Energetic Protons (SEPs), and outer radiation belt energetic electrons. The real-time radiation exposure is measured as an absorbed dose rate in silicon and then computed as an ambient dose equivalent rate for reporting dose relevant to radiative-sensitive organs and tissue in units of microsieverts per hour. ARMAS total ionizing absorbed dose is captured on the aircraft, downlinked in real-time, processed on the ground into ambient dose equivalent rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users. Dose rates from flight altitudes up to 56,700 ft. are shown for flights across the planet under a variety of space weather conditions. We discuss several space weather

  19. Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery.

    Science.gov (United States)

    Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P

    2013-03-01

    Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases

  20. Radiation measurements on the Mir Orbital Station

    International Nuclear Information System (INIS)

    Badhwar, G.D.; Atwell, W.; Reitz, G.; Beaujean, R.; Heinrich, W.

    2002-01-01

    Radiation measurements made onboard the MIR Orbital Station have spanned nearly a decade and covered two solar cycles, including one of the largest solar particle events, one of the largest magnetic storms, and a mean solar radio flux level reaching 250x10 4 Jansky that has been observed in the last 40 years. The cosmonaut absorbed dose rates varied from about 450 μGy day -1 during solar minimum to approximately half this value during the last solar maximum. There is a factor of about two in dose rate within a given module, and a similar variation from module to module. The average radiation quality factor during solar minimum, using the ICRP-26 definition, was about 2.4. The drift of the South Atlantic Anomaly was measured to be 6.0±0.5 deg. W, and 1.6±0.5 deg. N. These measurements are of direct applicability to the International Space Station. This paper represents a comprehensive review of Mir Space Station radiation data available from a variety of sources

  1. Radiation protection measuring device SSM-1

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    Product information from the producer on a universal measuring instrument for alpha, beta and gamma radiation designed for stationary and field use by military, police and fire brigades. 4 figs. (qui)

  2. Measurement of natural background radiation intensity on a train

    International Nuclear Information System (INIS)

    Chen, Y. F.; Lin, J. W.; Sheu, R. J.; Lin, U. T.; Jiang, S. H.

    2011-01-01

    This work aims to measure different components of natural background radiation on a train. A radiation measurement system consisting of four types of radiation detectors, namely, a Berkeley Lab cosmic-ray detector, moderated 3He detector, high pressure ionisation chamber and NaI(Tl) spectrometer, associated with a global positioning system unit was established for this purpose. For the commissioning of the system, a test measurement on a train along the railway around the northern Taiwan coast from Hsinchu to Hualien with a distance of ∼275 km was carried out. No significant variation of the intensities of the different components of natural background radiation was observed, except when the train went underground or in the tunnels. The average external dose rate received by the crew of the train was estimated to be 62 nSv h -1 . (authors)

  3. Measurement of Radiated Power Loss on EAST

    International Nuclear Information System (INIS)

    Duan Yanmin; Hu Liqun; Mao Songtao; Xu Ping; Chen Kaiyun; Lin Shiyao; Zhong Guoqiang; Zhang Jizong; Zhang Ling; Wang Liang

    2011-01-01

    A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (<0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.

  4. SIPRI's new conceptual approach to arms control and disarmament

    International Nuclear Information System (INIS)

    Rotfeld, Adam Daniel

    2000-01-01

    The end of the cold war deprioritized arms control and disarmament, and progress in the field was no longer a measure of relations among the major powers. In that context, the future of arms control and disarmament was discussed at the Nobel Symposium in October 1999. Stockholm International Peace Research Institute (SIPRI) views arms control as an instrument for shaping a new inclusive and cooperative security order. The author questions whether arms control challenges today can and should be resolved in the institutions established and the procedures elaborated in the bipolar framework. (author)

  5. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    Energy Technology Data Exchange (ETDEWEB)

    Salleh, H.; Matori, M. K.; Isa, M. J. M. [Agensi Nuklear Malaysia, Bangi, 43000 Kajang, Selangor (Malaysia); Samat, S. B. [Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor (Malaysia)

    2015-09-25

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube.

  6. Scattered radiation risk to the lens of the eyes for staff involved in using mobile C-arm fluoroscopy unit: Which position is riskiest?

    International Nuclear Information System (INIS)

    Salleh, H.; Matori, M. K.; Isa, M. J. M.; Samat, S. B.

    2015-01-01

    Cataractogenesis is something to be concerned by radiologist and radiographer who work extensively in fluoroscopy. The increasing use of fluoroscopy or interventional fluoroscopy has to come with safety awareness on scattered radiation risk for staff performing the procedure. This study is looking into the radiation risk to the lens of the eyes for staff involved in fluoroscopy using the mobile C-arm fluoroscopy unit. The Toshiba SXT-1000A and Alderson Rando phantom were used in this study. Based on the results, it is found clearly that over couch (OC) procedure is riskier than under couch (UC) procedure. The cathode bound area is clearly riskier than anode bound area especially for UC procedure. More doses (at least +1,568 % of safest position) are received by the lens of the eyes for staff standing at the cathode bound area especially the position opposite to the x-ray tube

  7. The problem of the detection threshold in radiation measurement

    International Nuclear Information System (INIS)

    Rose, E.; Wueneke, C.D.

    1983-01-01

    In all cases encountered in practical radiation measurement, the basic problem is to differentiate between the lowest measured value and the zero value (background, natural background radiation, etc.). For this purpose, on the mathematical side, tests based on hypotheses are to be applied. These will show the probability of differentiation between two values having the same random spread. By means of these tests and the corresponding error theory, a uniform treatment of the subject, applicable to all problems relating to measuring technique alike, can be found. Two basic concepts are found in this process, which have to be defined in terms of semantics and nomenclature: Decision threshold and detection threshold, or 'minimum detectable mean value'. At the decision threshold, one has to decide (with a given statistical error probability) whether a measured value is to be attributed to the background radiation, accepting the zero hypothesis, or whether this value differs significantly from the background radiation (error of 1rst kind). The minimum detectable mean value is the value which, with a given decision threshold, can be determined with sufficient significance to be a measured value and thus cannot be mistaken as background radiation (alternative hypothesis, error of 2nd kind). Normally, the two error types are of equal importance. It may happen, however, that one type of error gains more importance, depending on the approach. (orig.) [de

  8. INSTRUMENTATION FOR MEASURING AND TRANSMISSION THE SOLAR RADIATION THROUGH EARTH’S ATMOSPHERE

    Directory of Open Access Journals (Sweden)

    Alexandru Dan Toma

    2013-07-01

    Full Text Available The Sun's energy is distributed over a broad range of the electromagnetic spectrum and Sun behaves approximately like a "blackbody" radiating at a temperature of about 5800 K with maximum output in the green-yellow part of the visible spectrum, around 500 nm. Not all solar radiation reaching the top of the atmosphere reaches Earth's surface due to a various optical phenomena in regard to solar radiation crossing the Earth’s atmosphere. In order to investigate them, there are two general categories of instruments used to measure the transmission of solar radiation through Earth's atmosphere: instruments that measure radiation from the entire sky and instruments that measure only direct solar radiation. Within each of these categories, instruments can be further subdivided into those that measure radiation over a broad range of wavelengths and those that measure only specific wavelengths.

  9. A randomised clinical trial of misoprostol for radiation mucositis

    International Nuclear Information System (INIS)

    Faroudi, F.; Timms, I.; Sathiyuaseelan, Y.; Cakir, B.; Tiver, K.W.; Gebski, V.; Veness, M.

    2003-01-01

    Radiation mucositis is a major acute toxicity of radiation therapy for head and neck malignancies. We tested whether Misoprostol, a synthetic prostaglandin E 1 analogue given prophylactically decreased intensity of radiation mucositis. A double blind randomized trial was conducted. The intervention consisted of swishing dissolved drug or placebo as a mouthwash, and then swallowing two hours prior to radiation treatment. Patients were stratified based on concurrent chemotherapy, altered fractionation, smoking, extent of oral mucosa in radiation field, and institution. The main end point was the extent of RTOG grade III mucositis, taking into account both time and duration of mucositis. 42 patients were randomized to active drug, and 41 patients to placebo. The trial was designed to have 70 patients in each arm. The trial closed due to poor accrual. In the Misoprostol group 18/42 (43%) had grade III/IV mucositis, and in the placebo group 17/40 (42%). The mean difference between the areas under the curve was 0.38 (p-value: 0.38). For grade II mucositis the corresponding figures were 18 (42%) and 19 (47%). The time from commencement of radiation therapy to the development of peak mucositis was 49 days in the misoprostol patients and 51 days in the placebo group. The duration of grade III mucositis 12.5 days in the Misoprostol patients and 7 days in the placebo patients. In the Misoprostol arm 4 patients had an interruption to their Radiation Therapy, in the Placebo arm 5 had interruptions. Patients average weight loss was 8.1 and 8.2kg. Average self-assessment was via a 10cm LASA scale for soreness of throat and overall well-being. Misoprostol showed a worse QoL on soreness of mouth (mean difference: 0.84 units (p-value .03), but overall well-being was similar on both treatment arms 1 patient withdrew in the Misoprostol arm and 2 in the placebo arm. Misoprostol given prophylactically does not reduce the incidence of Grade III/IV mucositis, is associated with a shorter

  10. Evolution of robotic arms.

    Science.gov (United States)

    Moran, Michael E

    2007-01-01

    The foundation of surgical robotics is in the development of the robotic arm. This is a thorough review of the literature on the nature and development of this device with emphasis on surgical applications. We have reviewed the published literature and classified robotic arms by their application: show, industrial application, medical application, etc. There is a definite trend in the manufacture of robotic arms toward more dextrous devices, more degrees-of-freedom, and capabilities beyond the human arm. da Vinci designed the first sophisticated robotic arm in 1495 with four degrees-of-freedom and an analog on-board controller supplying power and programmability. von Kemplen's chess-playing automaton left arm was quite sophisticated. Unimate introduced the first industrial robotic arm in 1961, it has subsequently evolved into the PUMA arm. In 1963 the Rancho arm was designed; Minsky's Tentacle arm appeared in 1968, Scheinman's Stanford arm in 1969, and MIT's Silver arm in 1974. Aird became the first cyborg human with a robotic arm in 1993. In 2000 Miguel Nicolalis redefined possible man-machine capacity in his work on cerebral implantation in owl-monkeys directly interfacing with robotic arms both locally and at a distance. The robotic arm is the end-effector of robotic systems and currently is the hallmark feature of the da Vinci Surgical System making its entrance into surgical application. But, despite the potential advantages of this computer-controlled master-slave system, robotic arms have definite limitations. Ongoing work in robotics has many potential solutions to the drawbacks of current robotic surgical systems.

  11. Developing low-dose C-arm CT imaging for temporomandibular joint (TMJ) disorder in interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiaowei; Cahill, Anne Marie [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Felice, Marc [University of Pennsylvania, Environmental Health and Radiation Safety, Philadelphia, PA (United States); Johnson, Laura [Computed Tomography Division, Siemens Healthcare Sector, Shanghai (China); Sarmiento, Marily [Siemens Medical Solutions, Angiography and X-ray Division, Hoffman Estates, IL (United States)

    2011-04-15

    Manufacturers have provided C-arm CT imaging technologies for applications in interventional radiology in recent years. However, clinical imaging protocols and radiation doses have not been well studied or reported. The purpose of this study is to develop low-dose settings for clinically acceptable CT imaging of temporomandibular joint in interventional radiology suites, using a C-arm imaging angiography system. CT scans were performed with a flat-panel digital C-arm angiographic system on a 5-year-old anthropomorphic phantom. The CTDI was determined for various rotation times, dose settings and Cu filter selections. The CTDI values were compared with those of conventional low-dose CT for the same phantom. The effectiveness of using Cu filters to reduce dose was also investigated. Images were reviewed by a senior radiologist for clinical acceptance. The manufacturer's default setting gave an equivalent CTDI of 4.8 mGy. Optimizing the dose settings and adding copper filtration reduced the radiation dose by 94%. This represents a 50% reduction from conventional CT. Use of Cu filters and low-dose settings significantly reduced radiation dose from that of standard settings. This phantom study process successfully guided the clinical implementation of low-dose studies for all ages at our institution. (orig.)

  12. Radiation measured for ISS-Expedition 12 with different dosimeters

    International Nuclear Information System (INIS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Weyland, M.

    2007-01-01

    Radiation in low Earth orbit (LEO) is mainly from Galactic Cosmic Rays (GCR), solar energetic particles and particles in South Atlantic Anomaly (SAA). These particles' radiation impact to astronauts depends strongly on the particles' linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field and the influence of radiation on astronauts. At present, the best active dosimeters used for all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors; the best passive dosimeters are thermoluminescence dosimeters (TLDs) or optically stimulated luminescence dosimeters (OSLDs) for low LET and CR-39 plastic nuclear track detectors (PNTDs) for high LET. TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation for space mission Expedition 12 (ISS-11S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the mission with these different dosimeters. This paper introduces the operation principles for these dosimeters, describes the method to combine the results measured by CR-39 PNTDs and TLDs/OSLDs, presents the experimental LET spectra and the radiation quantities

  13. Camera-augmented mobile C-arm (CamC): A feasibility study of augmented reality imaging in the operating room.

    Science.gov (United States)

    von der Heide, Anna Maria; Fallavollita, Pascal; Wang, Lejing; Sandner, Philipp; Navab, Nassir; Weidert, Simon; Euler, Ekkehard

    2018-04-01

    In orthopaedic trauma surgery, image-guided procedures are mostly based on fluoroscopy. The reduction of radiation exposure is an important goal. The purpose of this work was to investigate the impact of a camera-augmented mobile C-arm (CamC) on radiation exposure and the surgical workflow during a first clinical trial. Applying a workflow-oriented approach, 10 general workflow steps were defined to compare the CamC to traditional C-arms. The surgeries included were arbitrarily identified and assigned to the study. The evaluation criteria were radiation exposure and operation time for each workflow step and the entire surgery. The evaluation protocol was designed and conducted in a single-centre study. The radiation exposure was remarkably reduced by 18 X-ray shots 46% using the CamC while keeping similar surgery times. The intuitiveness of the system, its easy integration into the surgical workflow, and its great potential to reduce radiation have been demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Traceability of radiation measurements: musings of a user

    International Nuclear Information System (INIS)

    Kathren, R.L.

    1980-04-01

    Although users of radiation desire measurement traceability for a number of reasons, including legal, regulatory, contractual, and quality assurance requirements, there exists no real definition of the term in the technical literature. Definitions are proposed for both traceability and traceability to the National Bureau of Standards. The hierarchy of radiation standards is discussed and allowable uncertainties are given for each level. Areas of need with respect to radiation standards are identified, and a system of secondary radiation calibration laboratories is proposed as a means of providing quality calibrations and traceability on a routine basis

  15. Traceability of radiation measurements: musings of a user

    Energy Technology Data Exchange (ETDEWEB)

    Kathren, R.L.

    1980-04-01

    Although users of radiation desire measurement traceability for a number of reasons, including legal, regulatory, contractual, and quality assurance requirements, there exists no real definition of the term in the technical literature. Definitions are proposed for both traceability and traceability to the National Bureau of Standards. The hierarchy of radiation standards is discussed and allowable uncertainties are given for each level. Areas of need with respect to radiation standards are identified, and a system of secondary radiation calibration laboratories is proposed as a means of providing quality calibrations and traceability on a routine basis.

  16. Measurement of background gamma radiation in the northern Marshall Islands.

    Science.gov (United States)

    Bordner, Autumn S; Crosswell, Danielle A; Katz, Ainsley O; Shah, Jill T; Zhang, Catherine R; Nikolic-Hughes, Ivana; Hughes, Emlyn W; Ruderman, Malvin A

    2016-06-21

    We report measurements of background gamma radiation levels on six islands in the northern Marshall Islands (Enewetak, Medren, and Runit onEnewetak Atoll; Bikini and Nam on Bikini Atoll; and Rongelap on Rongelap Atoll). Measurable excess radiation could be expected from the decay of (137)Cs produced by the US nuclear testing program there from 1946 to 1958. These recordings are of relevance to safety of human habitation and resettlement. We find low levels of gamma radiation for the settled island of Enewetak [mean = 7.6 millirem/year (mrem/y) = 0.076 millisievert/year (mSv/y)], larger levels of gamma radiation for the island of Rongelap (mean = 19.8 mrem/y = 0.198 mSv/y), and relatively high gamma radiation on the island of Bikini (mean = 184 mrem/y = 1.84 mSv/y). Distributions of gamma radiation levels are provided, and hot spots are discussed. We provide interpolated maps for four islands (Enewetak, Medren, Bikini, and Rongelap), and make comparisons to control measurements performed on the island of Majuro in the southern Marshall Islands, measurements made in Central Park in New York City, and the standard agreed upon by the United States and the Republic of the Marshall Islands (RMI) governments (100 mrem/y = 1 mSv/y). External gamma radiation levels on Bikini Island significantly exceed this standard (P = <0.01), and external gamma radiation levels on the other islands are below the standard. To determine conclusively whether these islands are safe for habitation, radiation exposure through additional pathways such as food ingestion must be considered.

  17. Recent developments and trends in radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Maushart, R.

    1993-01-01

    Measuring instruments used in radiation protection have undergone dramatic changes over the past decade. But also the attitude of users vis-a-vis this equipment is changing. This is reflected in changes in equipment concepts, the trend being towards 'considerate equipment' which does not absorb the user's attention, but reserves it for the real proposes of radiation protection. Just measuring is no longer enough. Measured data acquisition and evaluation must be integrated more closely, and more specifically, into an overall process of optimized in-plant radiation protection. A key role in this scheme is played by the application-oriented user interface, while measurement and testing routines become more and more automated. The technology now available for storing programs and data, interconnecting and displaying them in many ways, offers almost unlimited possibilities

  18. A comparison of entrance skin dose delivered by clinical angiographic c-arms using the real-time dosimeter: the MOSkin

    International Nuclear Information System (INIS)

    Thorpe, Nathan K.; Cutajar, Dean; Lian, Cheryl; Rosenfeld, Anatoly; Pitney, Mark; Friedman, Daniel; Perevertaylo, Vladimir

    2016-01-01

    Coronary angiography is a procedure used in the diagnosis and intervention of coronary heart disease. The procedure is often considered one of the highest dose diagnostic procedures in clinical use. Despite this, there is minimal use of dosimeters within angiographic catheterisation laboratories due to challenges resulting from their implementation. The aim of this study was to compare entrance dose delivery across locally commissioned c-arms to assess the need for real-time dosimetry solutions during angiographic procedures. The secondary aim of this study was to establish a calibration method for the MOSkin dosimeter that accurately produces entrance dose values from the clinically sampled beam qualities and energies. The MOSkin is a real-time dosimeter used to measure the skin dose delivered by external radiation beams. The suitability of the MOSkin for measurements in the angiographic catheterisation laboratory was assessed. Measurements were performed using a 30 × 30 × 30cm 3 PMMA phantom positioned at the rotational isocenter of the c-arm gantry. The MOSkin calibration factor was established through comparison of the MOSkin response to EBT2 film response. Irradiation of the dosimeters was performed using several clinical beam qualities ranging in energy from 70 to 105 kVp. A total of four different interventional c-arm machines were surveyed and compared using the MOSkin dosimeter. The phantom was irradiated from a normal angle of incidence using clinically relevant protocols, field sizes and source to image detector distance values. The MOSkin was observed to be radiotranslucent to the c-arm beam in all clinical environments. The MOSkin response was reproducible to within 2 % of the average value across repeated measurements for each beam setting. There were large variations in entrance dose delivery to the phantom between the different c-arm machines with the highest observed cine-acquisition entrance dose rate measuring 326 % higher than the lowest

  19. Radiofrequency (RF) radiation measurement for diathermy machine

    International Nuclear Information System (INIS)

    Rozaimah Abdul Rahim; Roha Tukimin; Mohd Amirul Nizam; Ahmad Fadzli; Mohd Azizi

    2010-01-01

    Full-text: Diathermy machine is one of medical device that use widely in hospital and clinic. During the diathermy treatment, high radiofrequency (RF) currents (shortwave and microwave) are used to heat deep muscular tissues through electromagnetic energy to body tissues. The heat increases blood flow, relieve pain and speeding up recovery. The stray RF radiation from the machine can exposes to unintended tissue of the patient, to the operator (physical therapist) and also can cause electromagnetic interference (EMI) effect to medical devices around the machine. The main objective of this study is to establish a database of the RF radiation exposure levels experienced by the operator and patient during the treatments. RF radiation (electric and magnetic field) produced by the diathermy machines were measured using special RF survey meters. The finding of this study confirms that radiation levels on the surface and near the applicator of the diathermy machine much more elevated due to the much closer distance to the source and they exceeding the occupational and general public exposure limit. The results also shows the field strengths drop very significantly when the distance of measurement increase. (author)

  20. 110. PTB seminar: Dose rate measurements of ionizing radiation in the range of natural ambient radiation. Proceedings

    International Nuclear Information System (INIS)

    Lauterbach, U.; Pessara, W.; Woehler-Figgen, S.

    1997-12-01

    Measuring instruments for radiation dose measurement in the range of natural ambient radiation are not subject to legal obligations for calibration and the PTB received numerous requests in the past, asking for measures to be taken in order to ensure reliability of measuring results in this range of radiation. This has induced PTB to organise the seminar, intended to present the current status of measuring technology in this field, reveal problems encountered in practical applications, and discuss suitable ction for quality assurance. The papers of the seminar report the measuring performance and capabilities of the available instruments, results of comparative analyses of measurements, and resulting proposed action for quality assurance. Discussions concluding the sessions are also presented in the processdings volume. (orig./CB) [de

  1. Situational awareness of hazards: Validation of multi-source radiation measurements

    Science.gov (United States)

    Hultquist, C.; Cervone, G.

    2016-12-01

    Citizen-led movements producing scientific hazard data during disasters are increasingly common. After the Japanese earthquake-triggered tsunami in 2011, and the resulting radioactive releases at the damaged Fukushima Daiichi nuclear power plants, citizens monitored on-ground levels of radiation with innovative mobile devices built from off-the-shelf components. To date, the citizen-led SAFECAST project has recorded 50 million radiation measurements worldwide, with the majority of these measurements from Japan. The analysis of data which are multi-dimensional, not vetted, and provided from multiple devices presents big data challenges due to their volume, velocity, variety, and veracity. While the SAFECAST project produced massive open-source radiation measurements at specific coordinates and times, the reliability and validity of the overall data have not yet been assessed. The nuclear disaster provides a case for assessing the SAFECAST data with official aerial remote sensing radiation data jointly collected by the governments of the United States and Japan. A spatial and statistical assessment of SAFECAST requires several preprocessing steps. First, SAFECAST ionized radiation sensors collected data using different units of measure than the government data, and they had to be converted. Secondly, the normally occurring radiation and decay rates of Cesium from deposition surveys were used to properly compare measurements in space and time. Finally, the GPS located points were selected within overlapping extents at multiple spatial resolutions. Quantitative measures were used to assess the similarity and differences in the observed measurements. Radiation measurements from the same geographic extents show similar spatial variations and statistically significant correlations. The results suggest that actionable scientific data for disasters and emergencies can be inferred from non-traditional and not vetted data generated through citizen science projects. This

  2. Measures against radiation disaster/terrorism and radiation emergency medical assistance team

    International Nuclear Information System (INIS)

    Tominaga, Takako; Akashi, Makoto

    2016-01-01

    The probability of occurrence of radiological terrorism and disaster in Japan is not low. For this reason, preparations for coping with the occurrence of radiological terrorism should be an urgent issue. This paper describes the radiation medical system and the threat of radiological terrorism and disaster in Japan, and introduces the Radiation Emergency Medical Assistance Team (REMAT), one of the radiation accident/disaster response organizations at the National Institute of Radiological Sciences. Radiation exposure medical systems in Japan are constructed only in the location of nuclear facilities and adjacent prefectures. These medical systems have been developed only for the purpose of medical correspondence at the time of nuclear disaster, but preparations are not made by assuming measures against radiological terrorism. REMAT of the National Institute of Radiological Sciences is obligated to dispatch persons to the requesting prefecture to support radiation medical care in case of nuclear disaster or radiation accident. The designation of nuclear disaster orientated hospitals in each region, and the training of nuclear disaster medical staffing team were also started, but preparations are not enough. In addition to enhancing and strengthening experts, specialized agencies, and special forces dealing with radiological terrorism, it is essential to improve regional disaster management capacity and terrorism handling capacity. (A.O.)

  3. The Impact of Radiation Therapy on the Risk of Lymphedema After Treatment for Breast Cancer: A Prospective Cohort Study

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Laura E.G.; Miller, Cynthia L. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Horick, Nora [Department of Biostatistics, Massachusetts General Hospital, Boston, Massachusetts (United States); Skolny, Melissa N.; Jammallo, Lauren S.; Sadek, Betro T.; Shenouda, Mina N. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); O' Toole, Jean A. [Department of Physical and Occupational Therapy, Massachusetts General Hospital, Boston, Massachusetts (United States); MacDonald, Shannon M. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Specht, Michelle C. [Division of Surgical Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Taghian, Alphonse G., E-mail: ataghian@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-03-01

    Purpose/Objective: Lymphedema after breast cancer treatment can be an irreversible condition with a negative impact on quality of life. The goal of this study was to identify radiation therapy-related risk factors for lymphedema. Methods and Materials: From 2005 to 2012, we prospectively performed arm volume measurements on 1476 breast cancer patients at our institution using a Perometer. Treating each breast individually, 1099 of 1501 patients (73%) received radiation therapy. Arm measurements were performed preoperatively and postoperatively. Lymphedema was defined as ≥10% arm volume increase occurring >3 months postoperatively. Univariate and multivariate Cox proportional hazard models were used to evaluate risk factors for lymphedema. Results: At a median follow-up time of 25.4 months (range, 3.4-82.6 months), the 2-year cumulative incidence of lymphedema was 6.8%. Cumulative incidence by radiation therapy type was as follows: 3.0% no radiation therapy, 3.1% breast or chest wall alone, 21.9% supraclavicular (SC), and 21.1% SC and posterior axillary boost (PAB). On multivariate analysis, the hazard ratio for regional lymph node radiation (RLNR) (SC ± PAB) was 1.7 (P=.025) compared with breast/chest wall radiation alone. There was no difference in lymphedema risk between SC and SC + PAB (P=.96). Other independent risk factors included early postoperative swelling (P<.0001), higher body mass index (P<.0001), greater number of lymph nodes dissected (P=.018), and axillary lymph node dissection (P=.0001). Conclusions: In a large cohort of breast cancer patients prospectively screened for lymphedema, RLNR significantly increased the risk of lymphedema compared with breast/chest wall radiation alone. When considering use of RLNR, clinicians should weigh the potential benefit of RLNR for control of disease against the increased risk of lymphedema.

  4. Radiation and impurity measurements in FRX-C/T

    International Nuclear Information System (INIS)

    Chrien, R.E.; McKenna, K.F.; Rej, D.J.; Tuszewski, M.

    1984-01-01

    Translation of Field-Reversed Configurations (FRCs) in the FRX-C/T device has provided better diagnostic access for radiation measurements. It is observed that radiated power accounts for 7 +- 2% of the total power losses, indicating that thermal conduction accounts for about half of the losses. It was determined through impurity seeding experiments that the oxygen fraction is 0.6 +- 0.2% and that oxygen can account for most of the radiated power

  5. Evidence for radiation-induced Bystander effects and relevance to radiotherapy and to radiation protection

    International Nuclear Information System (INIS)

    Georgieva, R.

    2006-01-01

    Full text: There are two major arms of radiation science in which Bystander effects (ByEff) could be of practical importance: radiotherapy and risk assessment. Basic biological principles, including dose-response relationships that have become dogma in the context of targeted effects of IR must now be reconsidered. The direct effects of radiation and the bystander components had to be reinvestigated to show the difference between them. It may be necessary to introduce a factor for ByEff's when calculating dose to both normal tissues and tumor. Presumably the relative effects on normal or tumor tissues could be different and that difference may not be always predictable. In relation to radiation protection, the existence of RIByEff's raises important questions for the way radiation dose is measured and modeled. The biological effect of exposure to low-doses radiation is likely to vary between individuals and between organs in one the same individual. Further studies on non-targeted effects should contribute to the establishment of adequate environmental and occupational radiation protection standards. This lecture looks at the history, the current data and controversies that are now beginning to resolve the questions concerning the mechanisms underlying the induction and transmission of ByEff. Especially, effects on radiotherapy and radiation protection are discussed

  6. One arm exercise induces significant interarm diastolic blood pressure difference.

    Science.gov (United States)

    Hong, Dezhi; Wang, Jiwei; Su, Hai; Xu, Jingsong; Liu, Yanna; Peng, Qiang; Wang, Lijuan

    2011-06-01

    This study is designed to investigate the inducing effect of one arm exercise on interarm difference (IAD) in the blood pressure (BP). Fifty healthy young participants were included in the study. Three-minute exercises of the right arm elbow flexion and extension were performed. The bilateral brachial BP was simultaneously measured with two automatic BP measurement devices before (basic) and immediately 0, 5, 10, 15, 20, and 30 min after exercise. The absolute difference in the systolic BP (SBP) and diastolic BP (DBP) between the left and right BP of at least 10 mmHg was recognized as sIAD and dIAD. The baseline data of the SBP and DBP in left and right arms revealed no significant difference (SBP: 110 ± 10 vs. 111 ± 11 mmHg; DBP: 66 ± 8 vs. 66 ± 9 mmHg, both not significant). The prevalence of dIAD was 2% at the baseline. However, this prevalence increased to 80% at 0 min, as right arm exercise induced the right DBP decrease and left DBP increase, and then the prevalence decreased gradually within a 30-min recovery period. The prevalence of sIAD was zero at the baseline and the maximal prevalence was 8% during the 20-min postexercise period. One arm exercise can lead to a significant IAD in DBP. Any arm exercise should be avoided before BP measurement.

  7. Lymphedema of the arm and breast in irradiated breast cancer patients: risks in an era of dramatically changing axillary surgery.

    Science.gov (United States)

    Goffman, Thomas E; Laronga, Christine; Wilson, Lori; Elkins, David

    2004-01-01

    The purpose of this study was to assess risk for lymphedema of the breast and arm in radiotherapy patients in an era of less extensive axillary surgery. Breast cancer patients treated for cure were reviewed, with a minimum follow-up of 1.5 years from the end of treatment. Clinical, surgical, and radiation-related variables were tested for statistical association with arm and breast lymphedema using regression analyses, t-tests, and chi-squared analyses. Between January 1998 and June 2001, 240 women received radiation for localized breast cancer in our center. The incidence of lymphedema of the ipsilateral breast, arm, and combined (breast and arm) was 9.6%, 7.6%, and 1.8%, respectively, with a median follow-up of 27 months. For breast edema, t-test and multivariate analysis showed body mass index (BMI) to be significant (p = 0.043, p = 0.0038), as was chi-squared and multivariate testing for site of tumor in the breast (p = 0.0043, p = 0.0035). For arm edema, t-test and multivariate analyses showed the number of nodes removed to be significant (p = 0.0040, p = 0.0458); the size of the tumor was also significant by multivariate analyses (p = 0.0027). Tumor size appeared significant because a number of very large cancers failed locally and caused cancer-related obstructive lymphedema. In our center, even modern, limited level 1-2 axillary dissection and tangential irradiation carries the risk of arm lymphedema that would argue in favor of sentinel node biopsy. For breast edema, disruption of draining lymphatics by surgery and radiation with boost to the upper outer quadrant increased risk, especially for the obese. Fortunately both breast and arm edema benefited from manual lymphatic drainage.

  8. Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

    Science.gov (United States)

    Mertens, Christopher J.; Gronoff, Guillaume P.; Norman, Ryan B.; Hayes, Bryan M.; Lusby, Terry C.; Straume, Tore; Tobiska, W. Kent; Hands, Alex; Ryden, Keith; Benton, Eric; hide

    2016-01-01

    The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

  9. Kootenay Lake Fertilization Experiment, Year 15 (North Arm) and Year 3 (South Arm) (2006) Report

    Energy Technology Data Exchange (ETDEWEB)

    Schindler, E.U.; Sebastian, D.; Andrusak, G.F. [Fish and Wildlife Science and Allocation, Ministry of Environment, Province of British Columbia

    2009-07-01

    This report summarizes results from the fifteenth year (2006) of nutrient additions to the North Arm of Kootenay Lake and three years of nutrient additions to the South Arm. Experimental fertilization of the lake has been conducted using an adaptive management approach in an effort to restore lake productivity lost as a result of nutrient uptake in upstream reservoirs. The primary objective of the experiment is to restore kokanee (Oncorhynchus nerka) populations, which are the main food source for Gerrard rainbow trout (Oncorhynchus mykiss) and bull trout (Salvelinus confluentus). The quantity of agricultural grade liquid fertilizer (10-34-0, ammonium polyphosphate and 28-0-0, urea ammonium nitrate) added to the North Arm in 2006 was 44.7 tonnes of P and 248.4 tonnes of N. The total fertilizer load added to the South Arm was 257 tonnes of nitrogen; no P was added. Kootenay Lake has an area of 395 km{sup 2}, a maximum depth of 150 m, a mean depth of 94 m, and a water renewal time of approximately two years. Kootenay Lake is a monomictic lake, generally mixing from late fall to early spring and stratifying during the summer. Surface water temperatures generally exceed 20 C for only a few weeks in July. Results of oxygen profiles were similar to previous years with the lake being well oxygenated from the surface to the bottom depths at all stations. Similar to past years, Secchi disc measurements at all stations in 2006 indicate a typical seasonal pattern of decreasing depths associated with the spring phytoplankton bloom, followed by increasing depths as the bloom gradually decreases by the late summer and fall. Total phosphorus (TP) ranged from 2-7 {micro}g/L and tended to decrease as summer advanced. Over the sampling season dissolved inorganic nitrogen (DIN) concentrations decreased, with the decline corresponding to nitrate (the dominant component of DIN) being utilized by phytoplankton during summer stratification. Owing to the importance of epilimnetic nitrate

  10. Using Radiation Pattern Measurements for Mobile Handset Performance Evaluation

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2005-01-01

    The mean effective gain (MEG) is an attractive performance measure of mobile handsets, since it incorporates both directional and polarization properties of the handset and environment. In this work the MEG is computed from measured spherical radiation patterns of five different mobile handsets...... values obtained for different orientations of the handsets in the environments. For practical measurements it is important to minimize the measurement time. The paper includes a study of the variation in MEG when the number of samples in the spherical radiation pattern is reduced. Furthermore...

  11. AmeriFlux Measurement Component (AMC) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Reichl, K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Biraud, S. C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-01-01

    An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

  12. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  13. Coordinated weather balloon solar radiation measurements during a solar eclipse.

    Science.gov (United States)

    Harrison, R G; Marlton, G J; Williams, P D; Nicoll, K A

    2016-09-28

    Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud. Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20 March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44°N, 0.94°W), Lerwick (60.15°N, 1.13°W) and Reykjavik (64.13°N, 21.90°W), straddling the path of the eclipse. The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming that the maximum solar radiation during a swing occurs when the photodiode sensing surface becomes normal to the direction of the solar beam. Both approaches, essentially independent, give values that agree with theoretical expectations for the eclipse-induced radiation changes.This article is part of the themed issue 'Atmospheric effects of solar eclipses stimulated by the 2015 UK eclipse'. © 2016 The Authors.

  14. Global real-time dose measurements using the Automated Radiation Measurements for Aerospace Safety (ARMAS) system

    Science.gov (United States)

    Tobiska, W. Kent; Bouwer, D.; Smart, D.; Shea, M.; Bailey, J.; Didkovsky, L.; Judge, K.; Garrett, H.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R.; Bell, D.; Mertens, C.; Xu, X.; Wiltberger, M.; Wiley, S.; Teets, E.; Jones, B.; Hong, S.; Yoon, K.

    2016-11-01

    The Automated Radiation Measurements for Aerospace Safety (ARMAS) program has successfully deployed a fleet of six instruments measuring the ambient radiation environment at commercial aircraft altitudes. ARMAS transmits real-time data to the ground and provides quality, tissue-relevant ambient dose equivalent rates with 5 min latency for dose rates on 213 flights up to 17.3 km (56,700 ft). We show five cases from different aircraft; the source particles are dominated by galactic cosmic rays but include particle fluxes for minor radiation periods and geomagnetically disturbed conditions. The measurements from 2013 to 2016 do not cover a period of time to quantify galactic cosmic rays' dependence on solar cycle variation and their effect on aviation radiation. However, we report on small radiation "clouds" in specific magnetic latitude regions and note that active geomagnetic, variable space weather conditions may sufficiently modify the magnetospheric magnetic field that can enhance the radiation environment, particularly at high altitudes and middle to high latitudes. When there is no significant space weather, high-latitude flights produce a dose rate analogous to a chest X-ray every 12.5 h, every 25 h for midlatitudes, and every 100 h for equatorial latitudes at typical commercial flight altitudes of 37,000 ft ( 11 km). The dose rate doubles every 2 km altitude increase, suggesting a radiation event management strategy for pilots or air traffic control; i.e., where event-driven radiation regions can be identified, they can be treated like volcanic ash clouds to achieve radiation safety goals with slightly lower flight altitudes or more equatorial flight paths.

  15. An Experiment in Radiation Measurement Using the Depron Instrument

    Science.gov (United States)

    Benghin, Victor V.; Nechaev, Oleg Y.; Zolotarev, Ivan A.; Amelyushkin, Alexander M.; Petrov, Vasiliy L.; Panasyuk, Milhail I.; Yashin, Ivan V.

    2018-02-01

    Most of the radiation measurements have been made onboard spacecraft flying along orbits with an inclination of up to 51.6 degrees. Due to the prospect of manned missions at orbits with larger inclinations, it is advisable to conduct preliminary detailed dosimetry measurements at a high-inclination orbit; due to its polar orbit, the Lomonosov satellite provides good opportunities for such study. We chose a method of cosmic radiation dosimetry based on semiconductor detectors. This method is widely used onboard spacecraft, including full-time radiation monitoring onboard the International Space Station (ISS). It should be noted that not only did the charged particles contribute significantly in the dose equivalent, but also did the neutrons. Semiconductor detectors have low sensitivity to neutron radiation and are not sufficient for detecting the expected flux of neutrons. We add a thermal neutron counter to the proposed device in order to provide an opportunity for estimation of neutron flux variations along the satellite trajectory. Thus, the design of the instrument DEPRON (Dosimeter of Electrons, PROtons and Neutrons) was determined. DEPRON is intended for registration of the absorbed doses and linear energy transfer spectra for high-energy electrons, protons and nuclei of space radiation, as well as registration of thermal neutrons. The present paper provides a brief description of the DEPRON instrument. Its calibration results and the first mission results of background radiation measurements are also presented.

  16. A Scintigraphic Method for Quantitation of Lymphatic Function in Arm Lymphedema

    DEFF Research Database (Denmark)

    Hvidsten, Svend; Toyserkani, Navid M; Sørensen, Jens A

    2018-01-01

    ) measure of lymph fluid passing through the arm. METHODS AND RESULTS: Eleven patients, aged 34-68 years, with unilateral arm lymphedema following breast cancer treatment underwent simultaneous bilateral lymphoscintigraphy using intradermal injection of 99mTc-labeled human serum albumin (HSA). Imaging...... was performed at 30-45 minute intervals for 5 hours. Time activity curves from each injection site and each arm region were recorded. The input into the arm region was obtained as the (minus) time derivative of the injection site activity curve. In the proposed model the arm activity curve was considered...

  17. Measurement of gamma radiation doses in nuclear power plant environment

    International Nuclear Information System (INIS)

    Bochvar, I.A.; Keirim-Markus, I.B.; Sergeeva, N.A.

    1976-01-01

    Considered are the problems of measuring gamma radiation dose values and the dose distribution in the nuclear power plant area with the aim of estimating the extent of their effect on the population. Presented are the dosimeters applied, their distribution throughout the controlled area, time of measurement. The distribution of gamma radiation doses over the controlled area and the dose alteration with the increase of the distance from the release source are shown. The results of measurements are investigated. The conclusion is made that operating nuclear power plants do not cause any increase in the gamma radiation dose over the area. Recommendations for clarifying the techniques for using dose-meters and decreasing measurement errors are given [ru

  18. WORKSPACE DRAWING FROM A MANIPULATOR ARM WITH 6 DOF

    Directory of Open Access Journals (Sweden)

    NAIDIN Gigi

    2011-06-01

    Full Text Available Modelling and simulation is an important aspect in robotic field. Knowing of the workspace is very important to the operation of manipulators arm. This paper investigates operational performance of space manipulator arm destined for industrial manufacturing, by defining and analyzing their workspace and manipulability measure. The authors show that manipulator arm developing requires the consideration of more efficient dynamic models and use of dedicated processing techniques such as Autodesk-Inventor 9, MATLAB, WorkSpace software.

  19. Estimation of diffuse from measured global solar radiation

    International Nuclear Information System (INIS)

    Moriarty, W.W.

    1991-01-01

    A data set of quality controlled radiation observations from stations scattered throughout Australia was formed and further screened to remove residual doubtful observations. It was then divided into groups by solar elevation, and used to find average relationships for each elevation group between relative global radiation (clearness index - the measured global radiation expressed as a proportion of the radiation on a horizontal surface at the top of the atmosphere) and relative diffuse radiation. Clear-cut relationships were found, which were then fitted by polynomial expressions giving the relative diffuse radiation as a function of relative global radiation and solar elevation. When these expressions were used to estimate the diffuse radiation from the global, the results had a slightly smaller spread of errors than those from an earlier technique given by Spencer. It was found that the errors were related to cloud amount, and further relationships were developed giving the errors as functions of global radiation, solar elevation, and the fraction of sky obscured by high cloud and by opaque (low and middle level) cloud. When these relationships were used to adjust the first estimates of diffuse radiation, there was a considerable reduction in the number of large errors

  20. Density measurement using gamma radiation - theory and application

    International Nuclear Information System (INIS)

    Springer, E.K.

    1979-01-01

    There are still widespread uncertainties about the use and safety of gamma radiation in industries. This paper describes, by the example of radiometric density measurement, the theory of gamma radiation. The differences and advantages of both types of detectors, the ionization chamber and the scintillation counter, are discussed. The degree of accuracy which can be expected from the radiometric density meter will be defined, and the inter-relationship: source strength - measuring range - measuring length(normally the pipe diameter) in relation to the measuring accuracy required will be explained in detail. The use of radioactive material requires the permission of the Atomic Energy Board. The formalities involved to receive a user's licence and the implementations of safety standards set by the local authorities are discussed in depth [af

  1. Design and Development of transducer for IR radiation measurement

    International Nuclear Information System (INIS)

    Pattarachindanuwong, Surat; Poopat, Bovornchoke; Meethong, Wachira

    2003-06-01

    Recently, IR radiation has many important roles such as for plastics industry, food industry and medical instrumentation. The consequence of exposed irradiation objects from IR can be greatly affected by the quantity of IR radiation. Therefore the objectively this research is to design and develop a transducer for IR radiation measurement. By using a quartz halogen lamp as a IR heat source of IR radiation and a thermopile sensor as a transducer. The thermal conductivity of transducer and air flow, were also considered for design and development of transducer. The study shows that the designed transducer can be used and applied in high temperature process, for example, the quality control of welding, the non-contact temperature measurement of drying oven and the testing of IR source in medical therapy device

  2. The Python ARM Radar Toolkit (Py-ART), a Library for Working with Weather Radar Data in the Python Programming Language

    OpenAIRE

    Helmus, Jonathan J; Collis, Scott M

    2016-01-01

    The Python ARM Radar Toolkit is a package for reading, visualizing, correcting and analysing data from weather radars. Development began to meet the needs of the Atmospheric Radiation Measurement Climate Research Facility and has since expanded to provide a general-purpose framework for working with data from weather radars in the Python programming language. The toolkit is built on top of libraries in the Scientific Python ecosystem including NumPy, SciPy, and matplotlib, and makes use of Cy...

  3. Radiation Dose Measurement Using Chemical Dosimeters

    International Nuclear Information System (INIS)

    Lee, Min Sun; Kim, Eun Hee; Kim, Yu Ri; Han, Bum Soo

    2010-01-01

    The radiation dose can be estimated in various ways. Dose estimates can be obtained by either experiment or theoretical analysis. In experiments, radiation impact is assessed by measuring any change caused by energy deposition to the exposed matter, in terms of energy state (physical change), chemical production (chemical change) or biological abnormality (biological change). The chemical dosimetry is based on the implication that the energy deposited to the matter can be inferred from the consequential change in chemical production. The chemical dosimetry usually works on the sample that is an aqueous solution, a biological matter, or an organic substance. In this study, we estimated absorbed doses by quantitating chemical changes in matter caused by radiation exposure. Two different chemical dosimeters, Fricke and ECB (Ethanol-Chlorobenzene) dosimeter, were compared in several features including efficacy as dose indicator and effective dose range

  4. Measurement techniques and safety culture in radiation protection -reflections after 37 years of occupation with measuring instruments

    International Nuclear Information System (INIS)

    Maushart, R.

    1994-01-01

    Safety Culture in radiation use and radiation protection implies primarily knowledge and competence of the decision makers. As the measuring techniques are basic for practical radiation protection, only such person can be called competent who has sufficient expertise on measuring techniques, and is able to evaluate its application and results. Safety Culture also implies the readiness to expose errors, and to learn from them. ''Believing in infallibility'' excludes Safety Culture. Therefore, correctly applied measuring technique contributes to recognize weak points early. How far it is used consciously and actively to prevent undesirable developments and exceeding of limits, can be considered outright as a yardstick for a high-ranking safety culture. Safety Culture as a whole, however, needs more than more measuring techniques. It requires its own and adequate Measurement Culture, presupposing also motivation and determination to measure. Therefore, education, training, knowledge and consciousness of safety of the people who are responsible for measurements are decisive for successful radiation protection. (orig.) [de

  5. Nuclear radiation in warfare

    International Nuclear Information System (INIS)

    Rotblat, J.

    1986-01-01

    The subject is covered in chapters, entitled: introduction; digest of nuclear weaponry (characteristics of nuclear weapons; effects of nuclear weapons other than ionizing radiation (fire-ball, fall-out, thermal radiation, blast wave, electromagnetic pulse); the nuclear arms race; war scenarios; biological effects of radiations on man (radiation doses; natural sources of radiation; acute effects of radiation; long-term somatic effects; genetic effects; factors affecting the biological response to radiation; internal exposure; synergistic effects; protection against radiation effects); radiations from nuclear explosions (initial radiation; fall-out; effects of fall-out on animal and plant life; contamination of water and food supplies by fall-out); radiation casualties in a nuclear war; effectiveness of civil defence; other warlike uses of radiation (attacks on civilian nuclear power installations; radiological warfare; terrorist activities); conclusion. (orig./HP) [de

  6. Nuclear radiation in warfare

    International Nuclear Information System (INIS)

    Rotblat, J.

    1981-01-01

    The subject is covered in chapters, entitled: introduction; digest of nuclear weaponry (characteristics of nuclear weapons; effects of nuclear weapons other than ionizing radiation (fire-ball, fall-out, thermal radiation, blast wave, electromagnetic pulse); the nuclear arms race; war scenarios); biological effects of radiations on man (radiation doses; natural sources of radiation; acute effects of radiation; long-term somatic effects; genetic effects; factors affecting the biological response to radiation; internal exposure; synergistic effects; protection against radiation effects); radiations from nuclear explosions (initial radiation; fall-out; effects of fall-out on animal and plant life; contamination of water and food supplies by fall-out); radiation casualties in a nuclear war; effectiveness of civil defence; other warlike uses of radiation (attacks on civilian nuclear power installations; radiological warfare; terrorist activities); conclusion. (U.K.)

  7. A radiation measurement study on cellular phone

    International Nuclear Information System (INIS)

    Mohd Yusof Mohd Ali; Rozaimah Abd Rahim; Roha Tukimin; Khairol Nizam Mohamed; Mohd Amirul Nizam Mohamad Thari; Ahmad Fadzli Ahmad Sanusi

    2007-01-01

    This paper will explain the radiation level produced by various selected cellular phone from various models and brands available in the market. The result obtained from this study will also recommend whether a cellular phone is safe for public usage or it might cause any effect on public health. Finally, a database of radiation measurement level produced by selected various cellular phone will also be developed and exhibited in this paper. (Author)

  8. Reduced-dose C-arm computed tomography applications at a pediatric institution

    Energy Technology Data Exchange (ETDEWEB)

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2017-12-15

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance. (orig.)

  9. Have Third-World Arms Industries Reduced Arms Imports?

    OpenAIRE

    Looney, R.E.

    1989-01-01

    Current Research on Peace and Violence, no. 1, 1989. Refereed Journal Article In 1945 only Argentina, Brazil, India and South Africa in the Third World possessed domestic arms industries which produced weapons systems other than small arms and ammunition (SIPRI, 1987, 76).

  10. The assessment of four different correction models applied to the diffuse radiation measured with a shadow ring using global and normal beam radiation measurements for Beer Sheva, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Kudish, Avraham I.; Evseev, Efim G. [Blaustein Institutes for Desert Research, Ben-Gurion University of the Negev, E D Bergmann Campus, Beer Sheva 84105 (Israel)

    2008-02-15

    The measurement of the diffuse radiation incident on a horizontal surface, a priori a straightforward task, is fraught with difficulties. It is possible to measure the diffuse radiation by three different techniques: two of which measure it directly and the third indirectly. The most accurate is the indirect one, which is based upon the concurrent measurements of the horizontal global and the normal incidence beam radiation. The disadvantage of this being the relatively expensive tracking system required for measuring the latter. The diffuse radiation can be measured directly with a pyranometer outfitted with either an occulting disk or shadow ring, which prevent the beam radiation from impinging on the pyranometer sensor. The occulting disk can provide accurate measurements of the diffuse radiation but it requires a relatively expensive sun tracking system in the east-west axis. The shadow ring is a stationary device with regard to the east-west axis and blocks the beam radiation component by creating a permanent shadow on the pyranometer sensor. The major disadvantage of the shadow ring is that it also blocks that portion of the diffuse radiation obscured by the shadow ring. This introduces a measurement error that must be corrected to account for that portion of the sky obscured by the shadow band. In addition to this geometric correction factor there is a need to correct for anisotropic sky conditions. Four correction models have been applied to the data for Beer Sheva, Israel and the results have been evaluated both graphically and statistically. An attempt has been made to score the relative performance of the models under different sky conditions. (author)

  11. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  12. Safeguarding arms control

    International Nuclear Information System (INIS)

    Flanagan, S.J.

    1988-01-01

    This essay reviews the evolution of various safeguards concepts associated with U.S. Soviet arms control negotiations over the past twenty-five years. It explore in some detail the origins, nature, and effectiveness of the safeguards packages associated with six agreements: the Limited Test Ban Treaty (1963), the SALT I Interim Agreement (1972), the Anti-Ballistic Missile (ABM) Treaty (1972), the Threshold Test Ban Treaty (1974), the Peaceful Nuclear Explosions Treaty (1976) and the SALT II Treaty (1979). Finally, the implications of this historical record for developing future nuclear and conventional arms control accords and for shoring up existing pacts, such as the ABM Treaty, are assessed with a view towards practicable prescriptions for Western policymakers. The treaty eliminating intermediate-range nuclear forces (INF) incorporates several verification safeguards, and it is very likely that analogous measures would be attached to any accord constraining conventional forces in Europe

  13. Development program of two-arm bilateral servomanipulator system for nuclear fuel cycle facilities in PNC

    International Nuclear Information System (INIS)

    Kashihara, H.; Igarashi, M.; Maeda, M.; Nomizu, T.; Uematsu, K.

    1984-01-01

    PNC started the development program of a two-arm bilateral servomanipulator to improve remote maintenance in the planning of pilot plants for HLLW vitrification and FBR fuel reprocessing. In this paper, the development program of two-arm bilateral servomanipulators, signal and power transmissions, high performance viewing system, man-machine interface, and transporter system for manipulators will be presented. Also radiation tests for all components used in a hot cell are being performed to aid remote system design

  14. Synchrotron X-ray scattering characterization of the molecular structures of star polystyrenes with varying numbers of arms.

    Science.gov (United States)

    Jin, Sangwoo; Higashihara, Tomoya; Jin, Kyeong Sik; Yoon, Jinhwan; Rho, Yecheol; Ahn, Byungcheol; Kim, Jehan; Hirao, Akira; Ree, Moonhor

    2010-05-20

    We have synthesized well-defined multiarmed star polystyrenes, with 6, 9, 17, 33, and 57 arms, and studied their molecular shapes and structural characteristics in a good solvent (tetrahydrofuran at 25 degrees C) and in a theta (Theta) solvent (cyclohexane at 35 degrees C) by small-angle X-ray scattering (SAXS) using a synchrotron radiation source. Analysis of the SAXS data provided a detailed characterization of the molecular shapes, including the contributions of the blob morphology of the arms, the radius of gyration, the paired distance distribution, the radial electron density distribution, and the Zimm-Stockmayer and Roovers g-factor, for the multiarmed star polystyrenes. In particular, the molecular shapes of the star polystyrenes were found to change from a fuzzy ellipsoid, for the 6-armed polystyrene, to a fuzzy sphere, for the 57-armed polystyrene, with an increasing number of arms. The ellipsoidal character of the star polystyrenes with fewer arms may originate from the extended anisotropically branched architecture at the center of the molecule. The arms of the star polystyrenes were found to be more extended than those of the linear polystyrenes. Furthermore, the degree of chain extension in the arms increased with the number of arms.

  15. Distribution measurement of radiation intensity with optical fiber at narrow space

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Chizuo [Nagoya Univ. (Japan). School of Engineering

    1998-07-01

    Recently, in the field or radiation measurement, optical fiber and scintillation fiber are also begun to use. In order to investigate a new application method of the optical fiber to radiation measurement, a lithium compound for neutron converter and a ZnS(Ag) scintillator are kneaded with epoxy type adhesives, and much few weight of them is coated at an end of optical fiber with 1 to 2 mm in diameter, which is further overcoated with black paint or an aluminum cap for its shielding light to produce a thermal neutron detector. The thermal neutron detector is found to be measurable to neutron flux distribution very rapidly and in high position resolution by moving with computer automatically. This method can be measured selctively aimed radiation such as thermal neutron, rapid neutron, {gamma}-ray, and so forth by means of changing the neutron converter. And, the developed fiber method could be widely used for measurement of neutron and {gamma}-ray intensity distribution at fine interval in the nuclear radiation facilities such as neighbors of accelerator facilities, medical radiation facilities. (G.K.)

  16. A relative difference in systolic blood pressure between arms by synchronal measurement and conventional cardiovascular risk factors are associated with the severity of coronary atherosclerosis.

    Science.gov (United States)

    Yamamoto, Tomohiko; Miura, Shin-Ichiro; Suematsu, Yasunori; Kuwano, Takashi; Sugihara, Makoto; Ike, Amane; Iwata, Atsushi; Nishikawa, Hiroaki; Saku, Keijiro

    2016-06-01

    It is not known the relationships between a difference in systolic blood pressure (SBP) or diastolic BP (DBP) between arms by synchronal measurement and the presence of coronary artery disease (CAD), and between a difference in BP between arms and the severity of coronary atherosclerosis. We enrolled 425 consecutive patients (M/F = 286/139, 67 ± 13 year) who were admitted to our University Hospital and in whom we could measure the absolute (|rt. BP - lt. BP|) and relative (rt. BP - lt. BP) differences in SBP and DBP using a nico PS-501(®) (Parama-Tech). We divided all patients into those who did and did not have CAD. The relative differences in SBP between arms in patients with CAD were significantly lower than those in patients without CAD. However, the relative difference in SBP between arms was not a predictor of the presence of CAD. We also divided 267 patients who underwent coronary angiography into tertiles according to the Gensini score (low, middle, and high score groups). Interestingly, the middle + high score groups showed significantly lower relative differences in SBP between arms than the low score group. The mean Korotkoff sound graph in the middle + high Gensini score group was significantly higher than that in the low Gensini score group. Among conventional cardiovascular risk factors and nico parameters, the relative difference in SBP between arms in addition to the risk factors (age, gender, body mass index, hypertension, dyslipidemia, and diabetes mellitus) was associated with the score by a logistic regression analysis. In conclusion, the relative difference in SBP between arms as well as conventional risk factors may be associated with the severity of coronary arteriosclerosis.

  17. Arm Pain

    Science.gov (United States)

    ... be a sign of a heart attack. Seek emergency treatment if you have: Arm, shoulder or back ... http://www.mayoclinic.org/symptoms/arm-pain/basics/definition/SYM-20050870 . Mayo Clinic Footer Legal Conditions and ...

  18. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the 'white-coat' effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-02-01

    Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.

  19. A prospective study of whether radiation pneumonitis is influenced by low-dose irradiated lung volume in primary lung cancer with chronic pulmonary disease

    International Nuclear Information System (INIS)

    Niibe, Yuzuru; Hayakawa, Kazushige; Masuda, Noriyuki; Yoshimura, Hirokuni

    2007-01-01

    The current study prospectively investigated the optimal dose-volume condition in cases of lung cancer with chronic pulmonary disease compared to those without chronic pulmonary disease. Cases of primary lung cancer treated with intended curative radiation therapy were registered in the current study. Their fraction size was limited to 2-3 Gy, so-called standard fractionation. They were prescribed a total dose of 60 Gy for non-small cell lung cancer (NSCLC; n=17) and a total dose of 54 Gy for small cell lung cancer (SCLC; n=4). Of the 21 patients enrolled in this study, 4 had chronic pulmonary disease (study arm), and the others had no chronic pulmonary disease (control arm). Seven received chemotherapy. Symptomatic radiation pneumonitis occurred in 5. Of the four patients in the study arm, two (50%) experienced symptomatic radiation pneumonitis; only 3 of the 17 patients in the control arm (17.6%) experienced symptomatic radiation pneumonitis. Furthermore, the median V 20 of patients who experienced symptomatic radiation pneumonitis in the study arm was 14%, which was higher than that of patients with no symptomatic radiation pneumonitis in the study arm, 5.8%. On the other hand, in the control arm, the median V 20 of patients with symptomatic radiation pneumonitis was 14.2%, about the same as that of patients with no symptomatic radiation pneumonitis in the control arm, 15.1%. The current study suggested that, as much as 15% of V 20 , might play an important role in cases of lung cancer with chronic pulmonary disease. (author)

  20. Aerial radiological measuring system program

    International Nuclear Information System (INIS)

    Doyle, J.F.; Boyns, P.K.

    1972-01-01

    The present ARMS aircraft has an effective survey time of four hours. Typical survey altitudes are 300 to 500 feet for terrain surveys and up to 20,000 feet for cloud tracks. A number of special airframe modifications have been made to accommodate the various sensor systems. The ARMS radiation measurement system consists of fourteen 4-inch diameter by 4-inch thick sodium iodide (NaI) detectors, a summing network for the detector signals, single and multichannel analyzers, analog computers, digital display and recording equipment, a doppler radar position computer, and strip chart recorders. Major subsystems include meteorology sensors, multispectral camera systems, and an infrared scanner for thermal mapping. Additional radiation detectors include an alpha spectrometer and a beta counter, used to count filter samples taken from a 150 cfm air sampler, which is a permanent part of the aircraft. A small lead shield houses a 1 / 2 -in. x 3-in. NaI crystal for beta and gamma counting of air filter samples. Several BF 3 neutron detectors are also available for neutron counting. The raw data from the gross gamma count and the gamma spectral measurements are permanently recorded on paper tape, and they must undergo reduction and analysis for final characterization of the radiological properties of the surveyed area. (U.S.)

  1. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi [Japan Nuclear Cycle Development Inst., Tokai, Ibaraki (Japan)

    2001-06-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  2. Measurement and assessment of doses from external radiations required for revised radiation protection regulations

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Kojima, Noboru; Hayashi, Naomi

    2001-01-01

    Radiation protection regulations based on the 1990 recommendations of ICRP have been revised and will take effect from Apr., 2001. The major changes concerning on the measurement and assessment of doses from external radiations are as follows. (1) Personal dose equivalent and ambient dose equivalent stated in ICRP Publication 74 are introduced as quantities to be measured with personal dosimeters and survey instruments, respectively. (2) For multiple dosimetry for workers, the compartment weighting factors used for a realistic assessment of effective dose are markedly changed. In advance of the introduction of the new radiation protection regulations, the impacts on workplace and personal monitoring for external radiations by these revisions were investigated. The following results were obtained. (1) A new ambient dose equivalent to neutrons is higher with a factor of 1.2 than the old one for moderated fission neutron spectra. Therefore, neutron dose equivalent monitors for workplace monitoring at MOX fuel for facilities should be recalibrated for measurement of the new ambient dose equivalent. (2) Annual effective doses of workers were estimated by applying new calibration factors to readings of personal dosimeters, worn by workers. Differences between effective doses and effective dose equivalents are small for workers engaged in the fabrication process of MOX fuel. (author)

  3. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  4. A new concept of feature-based gauge for coordinate measuring arm evaluation

    Science.gov (United States)

    Cuesta, E.; González-Madruga, D.; Alvarez, B. J.; Barreiro, J.

    2014-06-01

    Articulated arm coordinate measuring machines (AACMM or CMA) have conquered a market share in the actual dimensional metrology field, overall when their role implies the inspection of geometrical and dimensional tolerances in an accurate 3D environment for medium-size parts. However, the unavoidable fact of AACMM manual operation constrains its reliability to a great extent, avoiding rigorous evaluation and casting doubt upon the usefulness of external calibration. In this research, a dimensional gauge especially aimed at AACMM evaluation has been developed. Furthermore, the operator skill will be revealed through the use of this gauge. A set of geometrical features, some of them oriented to evaluate the operator and others the equipment, have been collected for the gauge. The proposed evaluation methodology clearly distinguishes between dimensional and geometrical tolerances (with or without datum references), whereas actual verification standards only consider the former. Next, quality indicators deduced from the measurement results are proposed in order to compare AACMM versus coordinate measuring machine (CMM) performance, assuming that CMM possess the maximum accuracy that AACMM could reach, because CMM combines maximum contact accuracy with minimum operator influence. As a result, AACMM evaluation time could be significantly reduced since this gauge allows us to perform a customized evaluation of only those specific tolerances of interest to the user.

  5. A new concept of feature-based gauge for coordinate measuring arm evaluation

    International Nuclear Information System (INIS)

    Cuesta, E; Alvarez, B J; González-Madruga, D; Barreiro, J

    2014-01-01

    Articulated arm coordinate measuring machines (AACMM or CMA) have conquered a market share in the actual dimensional metrology field, overall when their role implies the inspection of geometrical and dimensional tolerances in an accurate 3D environment for medium-size parts. However, the unavoidable fact of AACMM manual operation constrains its reliability to a great extent, avoiding rigorous evaluation and casting doubt upon the usefulness of external calibration. In this research, a dimensional gauge especially aimed at AACMM evaluation has been developed. Furthermore, the operator skill will be revealed through the use of this gauge. A set of geometrical features, some of them oriented to evaluate the operator and others the equipment, have been collected for the gauge. The proposed evaluation methodology clearly distinguishes between dimensional and geometrical tolerances (with or without datum references), whereas actual verification standards only consider the former. Next, quality indicators deduced from the measurement results are proposed in order to compare AACMM versus coordinate measuring machine (CMM) performance, assuming that CMM possess the maximum accuracy that AACMM could reach, because CMM combines maximum contact accuracy with minimum operator influence. As a result, AACMM evaluation time could be significantly reduced since this gauge allows us to perform a customized evaluation of only those specific tolerances of interest to the user. (paper)

  6. Development of radiation protection and measurement technology -A study on the radiation and environmental safety-

    International Nuclear Information System (INIS)

    Chang, Si Young; Seo, Kyeong Won; Yoon, Seok Cheol; Lee, Tae Yeong; Kim, Bong Hwan; Chung, Deok Yeon; Lee, Ki Chang; Kim, Jong Soo; Yoon, Yeo Chang; Kim, Jang Ryeol; Lee, Sang Yoon

    1994-07-01

    Reference radiation fields which can meet the national and international standard and criteria such as the ANSI N13.11 have been designed, produced and evaluated to maintain the national traceability and reliability of the radiation measurement and to provide precise calibration of the various radiation measuring instruments as well as standard irradiation of the personal dosimeters for the performance evaluation. Existing dose calculation algorithm has been improved to correctly evaluate the shallow dose from the β(Ti-204) + γ(Cs-137) mixed radiation exposure by applying the TLD response correction function newly derived in this study. A mathematical algorithm to calculate the internal dose from inhalation of the uranium isotopes has been developed on the basis of the ICRP-30 respiratory tract model. Detailed performance analysis of the KAERI lung counter has been carried out to participate in the intercomparison of lung dosimetry. A preliminary and basic study on the quantitative method of optimal dose reduction based on the ALARA concept has been performed to technically support and strengthen the national radiation protection infrastructure. (Author)

  7. Computer Language Choices in Arms Control and Nonproliferation Regimes

    International Nuclear Information System (INIS)

    White, G K

    2005-01-01

    The U.S. and Russian Federation continue to make substantive progress in the arms control and nonproliferation transparency regimes. We are moving toward an implementation choice for creating radiation measurement systems that are transparent in both their design and in their implementation. In particular, the choice of a programming language to write software for such regimes can decrease or significantly increase the costs of authentication. In this paper, we compare procedural languages with object-oriented languages. In particular, we examine the C and C++ languages; we compare language features, code generation, implementation details, and executable size and demonstrate how these attributes aid or hinder authentication and backdoor threats. We show that programs in lower level, procedural languages are more easily authenticated than are object-oriented ones. Potential tools and methods for authentication are covered. Possible mitigations are suggested for using object-oriented programming languages

  8. Estimation of Height from Arm Span in 6-11 Years Children in Odisha, India

    Directory of Open Access Journals (Sweden)

    Snigdha Prava Mishra

    2017-10-01

    Full Text Available Introduction: Standing height is an important anthropometric parameter to track longitudinal growth, to estimate body fatness and to calculate energy requirement. Measurement of height may be difficult in children who cannot stand. Aim: To establish regression equation for estimation of height from arm span in children. To check comparative relevancy of this equation with fixed height-to-arm span ratio (HAR for estimation of height. Materials and Methods: A cross-sectional study was conducted with 6-11 years school children (n=1465, Boys=774, Girls=691 in state of Odisha, India. Height was measured by portable stadiometer and arm span was measured by fiberglass measuring tape to nearest 0.1 cm. Pearson correlation and regression analysis was carried out between height and arm span data. p<0.05 (two tail was considered statistically significant. Results: Mean height and arm span in boys (124.16±8.74 cm and 125.57±10.43 cm respectively was significantly more (p<0.001 than height and arm span in girls (121.18±10.37 cm and 121.50±11.68 cm respectively. Mean HAR was 0.9942±0.0279. Correlation between height and arm span in boys was r = 0.94 (p<0.001 and in girls was r = 0.96 (p<0.001. Overall correlation coefficient was r = 0.95 (p<0.001. Regression equation for estimation of height from arm span was established: Height (cm = 0.8192 * arm span (cm + 21.46. Conclusion: Height in children of 6-11 years showed strong positive correlation with arm span. Regression equation established from this study can be used to estimate height from arm span. This estimation is more reliable than estimation of height from HAR.

  9. Studying and measuring the gamma radiation doses in Homs city

    International Nuclear Information System (INIS)

    Sofaan, A. H.

    2001-01-01

    The gamma radiation dose was measured in Homs city by using many portable dosimeters (electronic dosimeter and Geiger-Muller). The measurements were carried out in the indoor and outdoor buildings, for different time period, through one year (1999-2000). High purity germanium detector with low back ground radiation (HpGe) was used to determine radiation element contained in some building and the surrounding soil. The statistical analysis laws were applied to make sure that the measured dose distribution around average value is normal distribution. The measurement indicates that the gamma indoor dose varies from 312μSv/y to 511μSv/y, with the average annual dose of 385μSv/y. However the gamma outdoor dose rate varies from 307μSv/y to 366μSv/y with an average annual dose 385μSv/y. The annual outdoor gamma radiation dose is about %16 lower than the outdoor dose in Homs City. These measurements have indicated that environmental gamma doses in Homs City are relatively low. This is because that most of the soils and rocks in the area are limestone. (author)

  10. ACREM: A new air crew radiation exposure measuring system

    International Nuclear Information System (INIS)

    Beck, P.; Duftschmid, K.; Kerschbaumer, S.; Schmitzer, C.; Strachotinsky, C.; Grosskopf, A.; Winkler, N.

    1996-01-01

    Cosmic radiation has already been discovered in 1912 by the Austrian Nobel Laureate Victor F. Hess. After Hess up to now numerous measurements of the radiation exposure by cosmic rays in different altitudes have been performed, however, this has not been taken serious in view of radiation protection.Today, with the fast development of modern airplanes, an ever increasing number of civil aircraft is flying in increasing altitudes for considerable time. Members of civil aircrew spending up to 1000 hours per year in cruising altitudes and therefore are subject to significant levels of radiation exposure. In 1990 ICRP published its report ICRP 60 with updated excess cancer risk estimates, which led to significantly higher risk coefficients for some radiation qualities. An increase of the radiation weighting factors for mean energy neutron radiation increases the contribution for the neutron component to the equivalent dose by about 60%, as compared to the earlier values of ICRP26. This higher risk coefficients lead to the recommendation of the ICRP, that cosmic radiation exposure in civil aviation should be taken into account as occupational exposure. Numerous recent exposure measurements at civil airliners in Germany, Sweden, USA, and Russia show exposure levels in the range of 3-10 mSv/year. This is significantly more than the average annual dose of radiation workers (in Austria about 1.5 mSv/year). Up to now no practicable and economic radiation monitoring system for routine application on board exits. A fairly simple and economic approach to a practical, active in-flight dosimeter for the assessment of individual crew exposure is discussed in this paper

  11. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  12. Development of radiation protection and measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Si Young; Lee, T. Y.; Kim, J. L.; Kim, B. H.; Lee, B. J.; Chung, K. K.; Lee, K. C.; Chung, R. I.; Han, Y. D.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Yoon, K. S.; Jeong, D. Y.; Yoon, S. C.; Yoon, Y. C.; Lee, S. Y.; Kim, J. S.; Seo, K. W. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Kim, J. K.; Lee, J. K. [Hanyang Univ., Seoul (Korea, Republic of)

    1997-07-01

    Reference X-, gamma, beta and neutron radiation fields complying with the ISO and ANSI standards have been established and evaluated to provide a basic technical support in national radiation protection dosimetry program and to provide calibration measurement devices. Personal dose evaluation algorithm has been developed with these reference radiation fields, which comply well with both domestic and the new ANSI N13.11, to evaluate accurate personal dose equivalents. A personal internal dosimetry algorithm which can estimate the intakes of radionuclides from the results of in vivo bioassay and the resulting internal doses has been developed and verified its performance. It was also evaluated to be equality excellent compared with those being used in foreign countries and used to make a computer code for internal dose evaluation which can be run with PC under the Windows environment. A BOMAB phantom for precise calibration of in vivo system has been also designed, fabricated and test-evaluated. Based on the ALARA concept of the optimization principle of radiation protection, a method for estimating the cost for radiation protection has been studied and an objective monetary cost of detriment due to radiation exposure, called {alpha} value ($/man-Sv) has been derived and proposed based on the Korean socio-economic situation and human risk factors to provide basic data for the radiation protection optimization study in Korea. (author). 100 refs., 104 tabs., 69 figs.

  13. Circuit and Measurement Technique for Radiation Induced Drift in Precision Capacitance Matching

    Science.gov (United States)

    Prasad, Sudheer; Shankar, Krishnamurthy Ganapathy

    2013-04-01

    In the design of radiation tolerant precision ADCs targeted for space market, a matched capacitor array is crucial. The drift of capacitance ratios due to radiation should be small enough not to cause linearity errors. Conventional methods for measuring capacitor matching may not achieve the desired level of accuracy due to radiation induced gain errors in the measurement circuits. In this work, we present a circuit and method for measuring capacitance ratio drift to a very high accuracy (<; 1 ppm) unaffected by radiation levels up to 150 krad.

  14. Ultraviolet light and infrared radiation. Measurement and hazard assessment

    International Nuclear Information System (INIS)

    Mayer, A.; Salsi, S.

    1979-01-01

    Ultraviolet, light and infrared radiation exists in many work places and can be dangerous in many ways, especially for the eyes. The INRS has developed a method and an apparatus for measuring on site or in a laboratory the spectral energy distribution of such radiation and the luminance of the source. With current knowledge of the effects of radiation on the eyes and by comparing readings taken and recommended limit values, it is possible to determine the risk levels at work places in the different wave ranges. Two examples of readings taken at a pot furnace in a crystal glass factory and at an MAG welding station are given and the appropriate protective measures described [fr

  15. Measurement of microwave radiation from electron beam in the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, I.S.; Akimune, H. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Fukushima, M.; Ikeda, D. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Inome, Y. [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan); Matthews, J.N. [University of Utah, Salt Lake City, UT 4112-0830 (United States); Ogio, S. [Graduate School of Science, Osaka City University, Osaka 558-8585 (Japan); Sagawa, H. [Institute of Cosmic Ray Research, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Sako, T. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Tsukuba 305-0801 (Japan); Yamamoto, T., E-mail: tokonatu@konan-u.ac.jp [Faculty of Science and Engineering, Konan University, Kobe 658-8501 (Japan)

    2016-02-21

    We report the use of an electron light source (ELS) located at the Telescope Array Observatory in Utah, USA, to measure the isotropic microwave radiation from air showers. To simulate extensive air showers, the ELS emits an electron beam into the atmosphere and a parabola antenna system for the satellite communication is used to measure the microwave radiation from the electron beam. Based on this measurement, an upper limit on the intensity of a 12.5 GHz microwave radiation at 0.5 m from a 10{sup 18} eV air shower was estimated to be 3.96×10{sup −16} W m{sup −2} Hz{sup −1} with a 95% confidence level.

  16. Mechanical Impedance Modeling of Human Arm: A survey

    Science.gov (United States)

    Puzi, A. Ahmad; Sidek, S. N.; Sado, F.

    2017-03-01

    Human arm mechanical impedance plays a vital role in describing motion ability of the upper limb. One of the impedance parameters is stiffness which is defined as the ratio of an applied force to the measured deformation of the muscle. The arm mechanical impedance modeling is useful in order to develop a better controller for system that interacts with human as such an automated robot-assisted platform for automated rehabilitation training. The aim of the survey is to summarize the existing mechanical impedance models of human upper limb so to justify the need to have an improved version of the arm model in order to facilitate the development of better controller of such systems with ever increase in complexity. In particular, the paper will address the following issue: Human motor control and motor learning, constant and variable impedance models, methods for measuring mechanical impedance and mechanical impedance modeling techniques.

  17. First aid and subsequent measures after radiation accidents

    International Nuclear Information System (INIS)

    Flach, H.D.

    1980-01-01

    An organisation schedule and first aid measures after accidents involving ionizing radiation are presented, both in accordance with the current practice of the responsible professional associations. Optimum care also of persons with radiation injuries will be assured by cooperation between voluntary lay helpers, physicians, and regional centres in which failure symptons of the haematopoietic system can be treated. (DG) [de

  18. Spectroscopic and bolometric measurements of radiation loss in DIVA

    International Nuclear Information System (INIS)

    Shiho, Makoto; Odajima, Kazuo; Sugie, Tatsuo; Maeda, Hikosuke; Kasai, Satoshi

    1977-11-01

    Radiation loss due to low- and high-z impurities in DIVA (JFT-2a) was measured by means of a calibrated 3m grazing incidence vacuum monochromater and a calibrated pyroelectric detector. The following results were obtained: 1) Radiation loss power due to low-z impurities becomes insignificant by using clean surfaces for the vacuum wall. 2) Radiation loss power due to pseudo continuum from high-z impurities has influence on the energy balance of the confined plasma. 3) The divertor reduces the radiation loss by a factor of about 3. (auth.)

  19. Evaluating Radiative Closure in the Middle-to-Upper Troposhere

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, David C. [Univ. of Wisconsin, Madison, WI (United States); Turner, David D. [National Oceanic and Atmospheric Administration (NOAA), Boulder, CO (United States), Norman, OK (United States); Knuteson, Robert O. [Univ. of Wisconsin, Madison, WI (United States)

    2013-01-02

    This project had two general objectives. The first is the characterization and improvement of the radiative transfer parameterization in strongly absorbing water vapor bands, as these strongly absorbing bands dictate the clear sky radiative heating rate. The second is the characterization and improvement of the radiative transfer in cirrus clouds, with emphasis on ensuring that the parameterization of the radiative transfer is consistent and accurate across the spectrum. Both of these objectives are important for understanding the radiative processes in the mid-to-upper troposphere. The research on this project primarily involved analysis of data from the First and Second Radiative Heating in Underexplored Bands Campaigns, RHUBC-I and II. This included a climate model sensitivity study using results from RHUBC-I. The RHUBC experiments are ARM-funded activities that directly address the objectives of this research project. A secondary effort was also conducted that investigated the trends in the long-term (~14 year) dataset collected by the Atmospheric Emitted Radiance Interferometer (AERI) at the ARM Southern Great Plains site. This work, which was primarily done by a post-doc at the University of Wisconsin, Madison under Dr. Turner's direction, uses the only NIST-traceable instrument at the ARM site that has a well-documented calibration and uncertainty performance to investigate long-term trends in the downwelling longwave radiance above this site.

  20. Measurement of background gamma radiation in the northern Marshall Islands

    OpenAIRE

    Bordner, Autumn S.; Crosswell, Danielle A.; Katz, Ainsley O.; Shah, Jill T.; Zhang, Catherine R.; Nikolic-Hughes, Ivana; Hughes, Emlyn W.; Ruderman, Malvin A.

    2016-01-01

    Sixty-seven nuclear tests were conducted on two atolls in the northern Marshall Islands between 1946 and 1958. These tests produced radioactive fallout, which even today gives rise to radiation measurable above naturally occurring background levels. Rather than obtain new data, recent estimates of contamination levels in the northern Marshall Islands use measurements made decades ago to calculate present radiation levels. In contrast, we report on timely measurements on three different atolls...

  1. Tethered Balloon Operations at ARM AMF3 Site at Oliktok Point, AK

    Science.gov (United States)

    Dexheimer, D.; Lucero, D. A.; Helsel, F.; Hardesty, J.; Ivey, M.

    2015-12-01

    Oliktok Point has been the home of the Atmospheric Radiation Measurement Program's (ARM) third ARM Mobile Facility, or AMF3, since October 2013. The AMF3 is operated through Sandia National Laboratories and hosts instrumentation collecting continuous measurements of clouds, aerosols, precipitation, energy, and other meteorological variables. The Arctic region is warming more quickly than any other region due to climate change and Arctic sea ice is declining to record lows. Sparsity of atmospheric data from the Arctic leads to uncertainty in process comprehension, and atmospheric general circulation models (AGCM) are understood to underestimate low cloud presence in the Arctic. Increased vertical resolution of meteorological properties and cloud measurements will improve process understanding and help AGCMs better characterize Arctic clouds. SNL is developing a tethered balloon system capable of regular operation at AMF3 in order to provide increased vertical resolution atmospheric data. The tethered balloon can be operated within clouds at altitudes up to 7,000' AGL within DOE's R-2204 restricted area. Pressure, relative humidity, temperature, wind speed, and wind direction are recorded at multiple altitudes along the tether. These data were validated against stationary met tower data in Albuquerque, NM. The altitudes of the sensors were determined by GPS and calculated using a line counter and clinometer and compared. Wireless wetness sensors and supercooled liquid water content sensors have also been deployed and their data has been compared with other sensors. This presentation will provide an overview of the balloons, sensors, and test flights flown, and will provide a preliminary look at data from sensor validation campaigns and test flights.

  2. Differences Between Right and Left Arm Blood Pressures in the Elderly

    OpenAIRE

    Hashimoto, Fred; Hunt, William C.; Hardy, Linda

    1984-01-01

    Recommendations vary on whether blood pressures should be measured in the right or in the left arm because no frequency distributions for a pressure difference between the arms exist. We took a total of 12 blood pressure determinations in both arms of 174 elderly persons and analyzed the data by a least-squares components of variance method. The mean difference between the arms (right minus left) was 0.93 mm of mercury for systole and 0.70 mm of mercury for diastole. For systole the proportio...

  3. Solar radiation modeling and measurements for renewable energy applications: data and model quality

    International Nuclear Information System (INIS)

    Myers, Daryl R.

    2005-01-01

    Measurement and modeling of broadband and spectral terrestrial solar radiation is important for the evaluation and deployment of solar renewable energy systems. We discuss recent developments in the calibration of broadband solar radiometric instrumentation and improving broadband solar radiation measurement accuracy. An improved diffuse sky reference and radiometer calibration and characterization software for outdoor pyranometer calibrations are outlined. Several broadband solar radiation model approaches, including some developed at the National Renewable Energy Laboratory, for estimating direct beam, total hemispherical and diffuse sky radiation are briefly reviewed. The latter include the Bird clear sky model for global, direct beam, and diffuse terrestrial solar radiation; the Direct Insolation Simulation Code (DISC) for estimating direct beam radiation from global measurements; and the METSTAT (Meteorological and Statistical) and Climatological Solar Radiation (CSR) models that estimate solar radiation from meteorological data. We conclude that currently the best model uncertainties are representative of the uncertainty in measured data

  4. Solar radiation modeling and measurements for renewable energy applications: data and model quality

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D.R. [National Renewable Energy Laboratory, Golden, CO (United States)

    2005-07-01

    Measurement and modeling of broadband and spectral terrestrial solar radiation is important for the evaluation and deployment of solar renewable energy systems. We discuss recent developments in the calibration of broadband solar radiometric instrumentation and improving broadband solar radiation measurement accuracy. An improved diffuse sky reference and radiometer calibration and characterization software for outdoor pyranometer calibrations are outlined. Several broadband solar radiation model approaches, including some developed at the National Renewable Energy Laboratory, for estimating direct beam, total hemispherical and diffuse sky radiation are briefly reviewed. The latter include the Bird clear sky model for global, direct beam, and diffuse terrestrial solar radiation; the Direct Insolation Simulation Code (DISC) for estimating direct beam radiation from global measurements; and the METSTAT (Meteorological and Statistical) and Climatological Solar Radiation (CSR) models that estimate solar radiation from meteorological data. We conclude that currently the best model uncertainties are representative of the uncertainty in measured data. (author)

  5. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    Introductory material covers radiation sources, radiation interactions, general properties of radiation detectors, and counting statistics and error prediction. This is followed by detailed sections on gas-filled detectors, scintillation counters, semiconductor detectors, neutron detectors and spectroscopy, detector electronics and pulse processing, and miscellaneous radiation detectors and applications

  6. Radiation doses measured by TLD (thermo luminescent dosimeter) in x-ray examination

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hiraki, Motoji; Murakami, Shozo; Nishikawa, Naozo; Yagi, Takayuki

    1977-01-01

    By means of TLD, we measured the radiation doses to the skin in the central area of the field of radiation and doses scattered outside of the radiation field, utilizing a phantom to define a suitable radiation field. Clinically, when radiography of the gall bladder and the chest was done, we measured both the radiation doses of the central skin area where radiation was done and the skin above the area of the female gonads. In radiography of the chest, the radiation doses to the skin area above the female gonads situate was under 0.1 mR. When female gonads are less than 15 cm from the margin of the radiation field of the radiation dose can be decreased by 30% if gum sheets containing lead are used to cover the skin area outside the radiation field. (auth.)

  7. Statistics for Radiation Measurement. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Lötter, M. G. [Department of Medical Physics, University of the Free State, Bloemfontein (South Africa)

    2014-12-15

    Measurement errors are of three general types: (i) blunders, (ii) systematic errors or accuracy of measurements, and (iii) random errors or precision of measurements. Blunders produce grossly inaccurate results and experienced observers easily detect their occurrence. Examples in radiation counting or measurements include the incorrect setting of the energy window, counting heavily contaminated samples, using contaminated detectors for imaging or counting, obtaining measurements of high activities, resulting in count rates that lead to excessive dead time effects, and selecting the wrong patient orientation during imaging. Although some blunders can be detected as outliers or by duplicate samples and measurements, blunders should be avoided by careful, meticulous and dedicated work. This is especially important where results will determine the diagnosis or treatment of patients.

  8. Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke.

    Science.gov (United States)

    Mehrholz, Jan; Pohl, Marcus; Platz, Thomas; Kugler, Joachim; Elsner, Bernhard

    2015-11-07

    Electromechanical and robot-assisted arm training devices are used in rehabilitation, and may help to improve arm function after stroke. To assess the effectiveness of electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength in people after stroke. We also assessed the acceptability and safety of the therapy. We searched the Cochrane Stroke Group's Trials Register (last searched February 2015), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library 2015, Issue 3), MEDLINE (1950 to March 2015), EMBASE (1980 to March 2015), CINAHL (1982 to March 2015), AMED (1985 to March 2015), SPORTDiscus (1949 to March 2015), PEDro (searched April 2015), Compendex (1972 to March 2015), and Inspec (1969 to March 2015). We also handsearched relevant conference proceedings, searched trials and research registers, checked reference lists, and contacted trialists, experts, and researchers in our field, as well as manufacturers of commercial devices. Randomised controlled trials comparing electromechanical and robot-assisted arm training for recovery of arm function with other rehabilitation or placebo interventions, or no treatment, for people after stroke. Two review authors independently selected trials for inclusion, assessed trial quality and risk of bias, and extracted data. We contacted trialists for additional information. We analysed the results as standardised mean differences (SMDs) for continuous variables and risk differences (RDs) for dichotomous variables. We included 34 trials (involving 1160 participants) in this update of our review. Electromechanical and robot-assisted arm training improved activities of daily living scores (SMD 0.37, 95% confidence interval (CI) 0.11 to 0.64, P = 0.005, I² = 62%), arm function (SMD 0.35, 95% CI 0.18 to 0.51, P arm muscle strength (SMD 0.36, 95% CI 0.01 to 0.70, P = 0.04, I² = 72%), but the quality of the evidence was low to very low

  9. Development of PIMAL: Mathematical Phantom with Moving Arms and Legs

    Energy Technology Data Exchange (ETDEWEB)

    Akkurt, Hatice [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eckerman, Keith F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2007-05-01

    The computational model of the human anatomy (phantom) has gone through many revisions since its initial development in the 1970s. The computational phantom model currently used by the Nuclear Regulatory Commission (NRC) is based on a model published in 1974. Hence, the phantom model used by the NRC staff was missing some organs (e.g., neck, esophagus) and tissues. Further, locations of some organs were inappropriate (e.g., thyroid).Moreover, all the computational phantoms were assumed to be in the vertical-upright position. However, many occupational radiation exposures occur with the worker in other positions. In the first phase of this work, updates on the computational phantom models were reviewed and a revised phantom model, which includes the updates for the relevant organs and compositions, was identified. This revised model was adopted as the starting point for this development work, and hence a series of radiation transport computations, using the Monte Carlo code MCNP5, was performed. The computational results were compared against values reported by the International Commission on Radiation Protection (ICRP) in Publication 74. For some of the organs (e.g., thyroid), there were discrepancies between the computed values and the results reported in ICRP-74. The reasons behind these discrepancies have been investigated and are discussed in this report.Additionally, sensitivity computations were performed to determine the sensitivity of the organ doses for certain parameters, including composition and cross sections used in the simulations. To assess the dose for more realistic exposure configurations, the phantom model was revised to enable flexible positioning of the arms and legs. Furthermore, to reduce the user time for analyses, a graphical user interface (GUI) was developed. The GUI can be used to visualize the positioning of the arms and legs as desired posture is achieved to generate the input file, invoke the computations, and extract the organ dose

  10. A novel combination treatment of armed oncolytic adenovirus expressing IL-12 and GM-CSF with radiotherapy in murine hepatocarcinoma

    International Nuclear Information System (INIS)

    Kim, Wonwoo; Seong, Jinsil; Oh, Hae-Jin; Koom, Woong-Sub; Choi, Kyung-Joo; Yun, Chae-Ok

    2011-01-01

    In this study, a novel combination treatment of armed oncolytic adenovirus expressing interleukin 12 (IL-12) and granulocyte-macrophage colony-stimulating factor (GM-CSF) with radiation was investigated for antitumor and antimetastatic effect in a murine hepatic cancer (HCa-I) model. Tumor bearing syngeneic mice were treated with radiation, armed oncolytic virus Ad-ΔE1Bmt7 (dB7) expressing both IL-12 and GM-CSF (armed dB7), or a combination of both. The adenovirus was administered by intratumoral injection 1 x 10 8 plaque forming units (PFU) per tumor in 50 μl of phosphate buffered saline (PBS) four times every other day. Tumor response to treatment was determined by a tumor growth delay assay. Metastatic potential was evaluated by a lung metastasis model. To understand the underlying mechanism, the level of apoptosis was examined as well as the change in microvessel density and expression of immunological markers: CD4+, CD8+ and Cd11c. The combination of armed dB7 and radiation resulted in significant growth delay of murine hepatic cancer, HCa-1, with an enhancement factor of 4.3. The combination treatment also resulted in significant suppression of lung metastasis. Increase of apoptosis level as well as decrease of microvessel density was shown in the combination treatment, suggesting an underlying mechanism for the enhancement of antitumor effect. Expression of immunological markers: CD4+, CD8+ and Cd11c also increased in the combination treatment. This study showed that a novel combination treatment of radiotherapy with armed oncolytic adenovirus expressing IL-12 and GM-CSF was effective in suppressing primary tumor growth. (author)

  11. Fire and earthquake counter measures in radiation handling facilities

    International Nuclear Information System (INIS)

    1985-01-01

    'Fire countermeasures in radiation handling facilities' published in 1961 is still widely utilized as a valuable guideline for those handling radiation through the revision in 1972. However, science and technology rapidly advanced, and the relevant laws were revised after the publication, and many points which do not conform to the present state have become to be found. Therefore, it was decided to rewrite this book, and the new book has been completed. The title was changed to 'Fire and earthquake countermeasures in radiation handling facilities', and the countermeasures to earthquakes were added. Moreover, consideration was given so that the book is sufficiently useful also for those concerned with fire fighting, not only for those handling radiation. In this book, the way of thinking about the countermeasures against fires and earthquakes, the countermeasures in normal state and when a fire or an earthquake occurred, the countermeasures when the warning declaration has been announced, and the data on fires, earthquakes, the risk of radioisotopes, fire fighting equipment, the earthquake counter measures for equipment, protectors and radiation measuring instruments, first aid, the example of emergency system in radiation handling facilities, the activities of fire fighters, the example of accidents and so on are described. (Kako, I.)

  12. Accuracy of the WatchBP office ABI device for office blood pressure measurement over a wide range of arm sizes.

    Science.gov (United States)

    Palatini, Paolo; Fania, Claudio; Gasparotti, Federica

    2018-04-01

    The aim of this study was to determine the accuracy of the WatchBP Office ABI monitor for office blood pressure measurement over a wide range of arm circumferences using the ANSI/AAMI/ISO 81060-2:2013 protocol. The device accuracy was tested in 88 participants whose mean±SD age was 54.5±17.6 years, whose arm circumference was 30.6±8.3 cm (range: 15-46 cm), and whose entry blood pressure (BP) was 138.3±23.4 mmHg for systolic and 83.7±14.6 mmHg for diastolic BP. Four cuffs (small, standard, large, and extra-large) suitable for arm circumferences ranging from 14.0 to 52.0 cm were used. The mean device-observer difference in the 264 separate BP data pairs was 0.7±3.8 mmHg for systolic BP and was 0.0±3.7 mmHg for diastolic BP. These data were in agreement with criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). Moreover, criterion 2 was satisfied, the mean±SD device-observer difference of the 88 participants being 0.7±3.1 and 0.0±3.2 mmHg, respectively, for systolic and diastolic BP. Good agreement between observer and device was present across the whole range of arm circumferences. These data show that the Microlife WatchBP Office ABI monitor satisfied the ANSI/AAMI/ISO 81060-2:2013 standard requirements across a wide range of arm sizes.

  13. Measurement of global solar radiation over Brunei Darussalam

    International Nuclear Information System (INIS)

    Malik, A.Q.; Ak Abd Malik Abd Raub Pg Ghani

    2006-01-01

    Measurements of global solar radiation on a horizontal surface were carried out for a period of 11 months starting from June 2001 to April 2002. The pyrano meter (Kipp and Zonen) was placed at the top of the library building of University of Brunei Darussalam, which affords optimum exposure to the instrument sensor without appreciable obstacle for incoming global radiation. The maximum and minimum monthly-averaged global irradiations of 553 W/m 2 and 433 W/m 2 were recorded for the months of March and October respectively. The variation of global solar radiation can be divided into two distinct groups - the low radiation values being associated with cloud and turbidity while the high values are associated with less turbid and cloudy periods

  14. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the ‘white-coat’ effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-01-01

    Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681

  15. Evaluation of conventional and high-performance routine solar radiation measurements for improved solar resource, climatological trends, and radiative modeling

    Energy Technology Data Exchange (ETDEWEB)

    Gueymard, Christian A. [Solar Consulting Services, P.O. Box 392, Colebrook, NH 03576 (United States); Myers, Daryl R. [National Renewable Energy Laboratory, 1617 Cole Blvd., Golden, CO 80401-3305 (United States)

    2009-02-15

    The solar renewable energy community depends on radiometric measurements and instrumentation for data to design and monitor solar energy systems, and develop and validate solar radiation models. This contribution evaluates the impact of instrument uncertainties contributing to data inaccuracies and their effect on short-term and long-term measurement series, and on radiation model validation studies. For the latter part, transposition (horizontal-to-tilt) models are used as an example. Confirming previous studies, it is found that a widely used pyranometer strongly underestimates diffuse and global radiation, particularly in winter, unless appropriate corrective measures are taken. Other types of measurement problems are also discussed, such as those involved in the indirect determination of direct or diffuse irradiance, and in shadowband correction methods. The sensitivity of the predictions from transposition models to inaccuracies in input radiation data is demonstrated. Caution is therefore issued to the whole community regarding drawing detailed conclusions about solar radiation data without due attention to the data quality issues only recently identified. (author)

  16. Experimental measure of arm stiffness during single reaching movements with a time-frequency analysis

    OpenAIRE

    Piovesan, Davide; Pierobon, Alberto; DiZio, Paul; Lackner, James R.

    2013-01-01

    We tested an innovative method to estimate joint stiffness and damping during multijoint unfettered arm movements. The technique employs impulsive perturbations and a time-frequency analysis to estimate the arm's mechanical properties along a reaching trajectory. Each single impulsive perturbation provides a continuous estimation on a single-reach basis, making our method ideal to investigate motor adaptation in the presence of force fields and to study the control of movement in impaired ind...

  17. Clouds, Aerosol, and Precipitation in the Marine Boundary Layer: An ARM Mobile Facility Deployment

    Science.gov (United States)

    Wood, Robert; Wyant, Matthew; Bretherton, Christopher S.; Remillard, Jasmine; Kollias, Pavlos; Fletcher, Jennifer; Stemmler, Jayson; de Szoeke, Simone; Yuter, Sandra; Miller, Matthew; hide

    2015-01-01

    Capsule: A 21-month deployment to Graciosa Island in the northeastern Atlantic Ocean is providing an unprecedented record of the clouds, aerosols and meteorology in a poorly-sampled remote marine environment The Clouds, Aerosol, and Precipitation in the Marine Boundary Layer (CAP-MBL) deployment at Graciosa Island in the Azores generated a 21 month (April 2009- December 2010) comprehensive dataset documenting clouds, aerosols and precipitation using the Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF). The scientific aim of the deployment is to gain improved understanding of the interactions of clouds, aerosols and precipitation in the marine boundary layer. Graciosa Island straddles the boundary between the subtropics and midlatitudes in the Northeast Atlantic Ocean, and consequently experiences a great diversity of meteorological and cloudiness conditions. Low clouds are the dominant cloud type, with stratocumulus and cumulus occurring regularly. Approximately half of all clouds contained precipitation detectable as radar echoes below the cloud base. Radar and satellite observations show that clouds with tops from 1- 11 km contribute more or less equally to surface-measured precipitation at Graciosa. A wide range of aerosol conditions was sampled during the deployment consistent with the diversity of sources as indicated by back trajectory analysis. Preliminary findings suggest important two-way interactions between aerosols and clouds at Graciosa, with aerosols affecting light precipitation and cloud radiative properties while being controlled in part by precipitation scavenging. The data from at Graciosa are being compared with short-range forecasts made a variety of models. A pilot analysis with two climate and two weather forecast models shows that they reproduce the observed time-varying vertical structure of lower-tropospheric cloud fairly well, but the cloud-nucleating aerosol concentrations less well. The Graciosa site has been chosen to be a

  18. Clouds, Aerosols, and Precipitation in the Marine Boundary Layer: An Arm Mobile Facility Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Robert; Wyant, Matthew; Bretherton, Christopher S.; Rémillard, Jasmine; Kollias, Pavlos; Fletcher, Jennifer; Stemmler, Jayson; de Szoeke, Simone; Yuter, Sandra; Miller, Matthew; Mechem, David; Tselioudis, George; Chiu, J. Christine; Mann, Julian A. L.; O’Connor, Ewan J.; Hogan, Robin J.; Dong, Xiquan; Miller, Mark; Ghate, Virendra; Jefferson, Anne; Min, Qilong; Minnis, Patrick; Palikonda, Rabindra; Albrecht, Bruce; Luke, Ed; Hannay, Cecile; Lin, Yanluan

    2015-03-01

    The Clouds, Aerosol, and Precipitation in the Marine Boundary Layer (CAP-MBL) 38 deployment at Graciosa Island in the Azores generated a 21 month (April 2009-December 2010) 39 comprehensive dataset documenting clouds, aerosols and precipitation using the Atmospheric 40 Radiation Measurement (ARM) Mobile Facility (AMF). The scientific aim of the deployment is 41 to gain improved understanding of the interactions of clouds, aerosols and precipitation in the 42 marine boundary layer. 43 Graciosa Island straddles the boundary between the subtropics and midlatitudes in the 44 Northeast Atlantic Ocean, and consequently experiences a great diversity of meteorological and 45 cloudiness conditions. Low clouds are the dominant cloud type, with stratocumulus and cumulus 46 occurring regularly. Approximately half of all clouds contained precipitation detectable as radar 47 echoes below the cloud base. Radar and satellite observations show that clouds with tops from 1-48 11 km contribute more or less equally to surface-measured precipitation at Graciosa. A wide 49 range of aerosol conditions was sampled during the deployment consistent with the diversity of 50 sources as indicated by back trajectory analysis. Preliminary findings suggest important two-way 51 interactions between aerosols and clouds at Graciosa, with aerosols affecting light precipitation 52 and cloud radiative properties while being controlled in part by precipitation scavenging. 53 The data from at Graciosa are being compared with short-range forecasts made a variety 54 of models. A pilot analysis with two climate and two weather forecast models shows that they 55 reproduce the observed time-varying vertical structure of lower-tropospheric cloud fairly well, 56 but the cloud-nucleating aerosol concentrations less well. The Graciosa site has been chosen to 57 be a long-term ARM site that became operational in October 2013.

  19. Application of a universal optic data link for radiation measurements

    International Nuclear Information System (INIS)

    Komatsu, T.; Takada, E.

    2002-01-01

    Optic Data Link (ODL) is a device to convert electric and optic signals to each other, which is used for the field of optical communications. We examined the possibility to apply ODLs to radiation measurements. The effect of ODLs on energy and timing resolution has been investigated. From the results, fundamental applicability of ODLs to radiation measurements has been demonstrated. (author)

  20. ''Intelligent'' radiation measurements

    International Nuclear Information System (INIS)

    Ward, A.

    1980-01-01

    A description is given of three applications of current microprocessor technology which are characterized by the use of the microprocessor to impart a degree of intelligence to conventional radiation detection techniques. In the first application the microcomputer computes the radiation dose from the observed counting rate in a Geiger counter. In the second application the microcomputer provides the pulse height distribution and the radioisotopes used, from the spectrum of pulses from a scintillation counter. The third application is an arrangement for radiation monitor calibration. (H.K.)