WorldWideScience

Sample records for radiation calibration sistema

  1. Radiation calibration for LWIR Hyperspectral Imager Spectrometer

    Science.gov (United States)

    Yang, Zhixiong; Yu, Chunchao; Zheng, Wei-jian; Lei, Zhenggang; Yan, Min; Yuan, Xiaochun; Zhang, Peizhong

    2014-11-01

    The radiometric calibration of LWIR Hyperspectral imager Spectrometer is presented. The lab has been developed to LWIR Interferometric Hyperspectral imager Spectrometer Prototype(CHIPED-I) to study Lab Radiation Calibration, Two-point linear calibration is carried out for the spectrometer by using blackbody respectively. Firstly, calibration measured relative intensity is converted to the absolute radiation lightness of the object. Then, radiation lightness of the object is is converted the brightness temperature spectrum by the method of brightness temperature. The result indicated †that this method of Radiation Calibration calibration was very good.

  2. Calibration services for medical applications of radiation

    Energy Technology Data Exchange (ETDEWEB)

    DeWerd, L.A.

    1993-12-31

    Calibration services for the medical community applications of radiation involve measuring radiation precisely and having traceability to the National Institute of Standards and Technology (NIST). Radiation therapy applications involve the use of ionization chambers and electrometers for external beams and well-type ionization chamber systems as well as radioactive sources for brachytherapy. Diagnostic x-ray applications involve ionization chamber systems and devices to measure other parameters of the x-ray machine, such as non-invasive kVp meters. Calibration laboratories have been established to provide radiation calibration services while maintaining traceability to NIST. New radiation applications of the medical community spur investigation to provide the future calibration needs.

  3. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  4. CERN radiation protection (RP) calibration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Fabio

    2016-04-14

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelerators and at the CERN borders. A new state-of-the-art radiation protection calibration facility was designed, constructed and commissioned following the related ISO recommendations to replace the previous ageing (more than 30 years old) laboratory. In fact, the new laboratory aims also at the official accreditation according to the ISO standards in order to be able to release certified calibrations. Four radiation fields are provided: neutrons, photons and beta sources and an X-ray generator. Its construction did not only involve a pure civil engineering work; many radiation protection studies were performed to provide a facility that could answer the CERN calibration needs and fulfill all related safety requirements. Monte Carlo simulations have been confirmed to be a valuable tool for the optimization of the building design, the radiation protection aspects, e.g. shielding, and, as consequence, the overall cost. After the source and irradiator installation

  5. Calibration method for a in vivo measurement system using mathematical simulation of the radiation source and the detector; Metodo de calibracao de um sistema de medida in vivo atraves da simulacao matematica da fonte de radiacao e do detector

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, John

    1998-12-31

    A Monte Carlo program which uses a voxel phantom has been developed to simulate in vivo measurement systems for calibration purposes. The calibration method presented here employs a mathematical phantom, produced in the form of volume elements (voxels), obtained through Magnetic Resonance Images of the human body. The calibration method uses the Monte Carlo technique to simulate the tissue contamination, the transport of the photons through the tissues and the detection of the radiation. The program simulates the transport and detection of photons between 0.035 and 2 MeV and uses, for the body representation, a voxel phantom with a format of 871 slices each of 277 x 148 picture elements. The Monte Carlo code was applied to the calibration of in vivo systems and to estimate differences in counting efficiencies between homogeneous and non-homogeneous radionuclide distributions in the lung. Calculations show a factor of 20 between deposition of {sup 241} Am at the back compared with the front of the lung. The program was also used to estimate the {sup 137} Cs body burden of an internally contaminated individual, counted with an 8 x 4 Nal (TI) detector and an {sup 241} Am body burden of an internally contaminated individual, who was counted using a planar germanium detector. (author) 24 refs., 38 figs., 23 tabs.

  6. Precision Calibration of Infrared Synchrotron Radiation Detectors

    CERN Document Server

    Maltsev, A A; Maslova, M V

    2003-01-01

    The technique of calibration of synchrotron radiation precision detectors on a tungsten source based on similarity (close similarity) of character of spectral distributions of synchrotron and thermal radiations is given. The characteristics of various commonly used lamps, used as "standard" ones, are given. The errors of measurements are analyzed. The detectors are intended for absolute measurements of the number of electrons in a ring-shaped bunch.

  7. New radiation protection calibration facility at CERN.

    Science.gov (United States)

    Brugger, Markus; Carbonez, Pierre; Pozzi, Fabio; Silari, Marco; Vincke, Helmut

    2014-10-01

    The CERN radiation protection group has designed a new state-of-the-art calibration laboratory to replace the present facility, which is >20 y old. The new laboratory, presently under construction, will be equipped with neutron and gamma sources, as well as an X-ray generator and a beta irradiator. The present work describes the project to design the facility, including the facility placement criteria, the 'point-zero' measurements and the shielding study performed via FLUKA Monte Carlo simulations.

  8. Calibration of a TLD system to estimate personal doses in fields of gamma-neutrons radiation; Calibracion de un sistema TLD para estimar dosis personal en campos de radiacion gamma-neutrones

    Energy Technology Data Exchange (ETDEWEB)

    Villegas, E.N.; Somarriba, S.I., E-mail: evillegas@unan.edu.ni [Lab. de Fisica de Radiaciones y Metrologia, Universidad Nacional Autonoma de Nicaragua (Nicaragua)

    2016-07-01

    Currently Nicaragua has no personal neutron dosimetry system. The calibration of a batch of albedo neutron dosimeters consisting of two pairs of {sup 6}LiF and {sup 7}LiF (Mg, Ti) detectors was done. The dosimeter and reader sensitivities were obtained using a {sup 137}Cs source, and a neutron calibration factor was found with a {sup 241}AmBe source. Reproducibility and homogeneity tests were performed, and the detection limit of the system was determined. This calibration will allow the beginning of neutron personal monitoring in the country. (author)

  9. Calibration of a Stereo Radiation Detection Camera Using Planar Homography

    Directory of Open Access Journals (Sweden)

    Seung-Hae Baek

    2016-01-01

    Full Text Available This paper proposes a calibration technique of a stereo gamma detection camera. Calibration of the internal and external parameters of a stereo vision camera is a well-known research problem in the computer vision society. However, few or no stereo calibration has been investigated in the radiation measurement research. Since no visual information can be obtained from a stereo radiation camera, it is impossible to use a general stereo calibration algorithm directly. In this paper, we develop a hybrid-type stereo system which is equipped with both radiation and vision cameras. To calibrate the stereo radiation cameras, stereo images of a calibration pattern captured from the vision cameras are transformed in the view of the radiation cameras. The homography transformation is calibrated based on the geometric relationship between visual and radiation camera coordinates. The accuracy of the stereo parameters of the radiation camera is analyzed by distance measurements to both visual light and gamma sources. The experimental results show that the measurement error is about 3%.

  10. Calibration of routine dosimeters in radiation processing: Validation procedure for in-plant calibration

    Directory of Open Access Journals (Sweden)

    Šećerov Bojana Lj.

    2011-01-01

    Full Text Available The essential prerequisite of radiation dosimetry is to provide quality assurance and documentation that the irradiation procedure has been carried out according to the specification requirement of correct calibration of the chosen dosimetry system. At the Radiation Plant of the Vinča Institute of Nuclear Sciences we compared two recommended protocols of irradiation procedures in the calibration of dosimetry systems in radiation processing: (1 by irradiation of routine dosimeters (ethanol-chlorobenzene - ECB at the calibration laboratory and (2, by in-plant calibration with alanine transfer - dosimeters. The critical point for in-plant calibration is irradiation geometry, so we carefully positioned the phantom carrying both dosimeters in order to minimize dose gradients across the sample. The analysis of results obtained showed that the difference among determined absorbed doses for the construction of calibration curves between these two methods, (alanine vs. ECB, is less than 1%. The difference in combined standard uncertainty for each calibration procedure is 0.1%. These results demonstrate that our in-plant calibration is as good as calibration by irradiation at the calibration laboratory and validates our placement of the irradiation phantom during irradiation.

  11. Monochromator-Based Absolute Calibration of Radiation Thermometers

    Science.gov (United States)

    Keawprasert, T.; Anhalt, K.; Taubert, D. R.; Hartmann, J.

    2011-08-01

    A monochromator integrating-sphere-based spectral comparator facility has been developed to calibrate standard radiation thermometers in terms of the absolute spectral radiance responsivity, traceable to the PTB cryogenic radiometer. The absolute responsivity calibration has been improved using a 75 W xenon lamp with a reflective mirror and imaging optics to a relative standard uncertainty at the peak wavelength of approximately 0.17 % ( k = 1). Via a relative measurement of the out-of-band responsivity, the spectral responsivity of radiation thermometers can be fully characterized. To verify the calibration accuracy, the absolutely calibrated radiation thermometer is used to measure Au and Cu freezing-point temperatures and then to compare the obtained results with the values obtained by absolute methods, resulting in T - T 90 values of +52 mK and -50 mK for the gold and copper fixed points, respectively.

  12. Calibration for Radiation Protection Equipment for the Measuring Airborne Tritium

    Institute of Scientific and Technical Information of China (English)

    CHEN; Xi-lin; SHEN; En-wei; WEI; Ke-xin; WANG; Kong-zhao; LI; Hou-wen; GE; Jian-an; LV; Xiao-xia

    2012-01-01

    <正>Monitoring airborne tritium is an important routine work in heavy water reactor nuclear power stations and the units related with tritium. Nowadays direct measuring instruments like hand carrying tritium monitors are more often used in routine workshop environment check. Need for calibrating such monitors was suggested. A trial work about the calibration for radiation protection equipment for measuring airborne tritium was carried out with a domestic standard EJ/T 1077-1998 equivalent that of IEC 710.

  13. Calibration of the active radiation detector for Spacelab-One

    Science.gov (United States)

    1982-01-01

    The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

  14. Monochromator-Based Absolute Calibration of a Standard Radiation Thermometer

    Science.gov (United States)

    Mantilla, J. M.; Hernanz, M. L.; Campos, J.; Martín, M. J.; Pons, A.; del Campo, D.

    2014-04-01

    Centro Español de Metrología (CEM) is disseminating the International Temperature Scale (ITS-90), at high temperatures, by using the fixed points of Ag and Cu and a standard radiation thermometer. However, the future mise-en-pratique for the definition of the kelvin ( MeP-K) will include the dissemination of the kelvin by primary methods and by indirect approximations capable of exceptionally low uncertainties or increased reliability. Primary radiometry is, at present, able to achieve uncertainties competitive with the ITS-90 above the silver point with one of the possible techniques the calibration for radiance responsivity of an imaging radiometer (radiance method). In order to carry out this calibration, IO-CSIC (Spanish Designated Institute for luminous intensity and luminous flux) has collaborated with CEM, allowing traceability to its cryogenic radiometer. A monochromator integrating sphere-based spectral comparator facility has been used to calibrate one of the CEM standard radiation thermometers. The absolute calibrated standard radiation thermometer has been used to determine the temperatures of the fixed points of Cu, Co-C, Pt-C, and Re-C. The results obtained are 1357.80 K, 1597.10 K, 2011.66 K, and 2747.64 K, respectively, with uncertainties ranging from 0.4 K to 1.1 K.

  15. Calibration of the Standards and Calibration Laboratory`s Co{sup 60} Radiation Pool

    Energy Technology Data Exchange (ETDEWEB)

    Wirtenson, G.R.; White, R.H.

    1993-01-01

    The authors report measurements of dose rates at various locations in the LLNL Standards and Calibrations Laboratory`s Co{sup 60} Radiation Pool. Plots show the dependence of dose rate on radius near the bottom of the pool and the dependence of dose rate on height at a fixed distance from the pool center. The effect of varying sample location within the pool`s dry-well was also investigated.

  16. Simplified calibration for broadband solar ultraviolet radiation measurements.

    Science.gov (United States)

    Oppenrieder, A; Hoeppe, P; Koepke, P; Reuder, J; Schween, J; Schreder, J

    2003-12-01

    Aspects of different calibration procedures for erythemally weighing broadband radiometers are presented in this study. These instruments are common in projects dealing with ultraviolet radiation effects on humans. Many erythemally weighing broadband radiometers are still operated using a single calibration factor (cf) that is provided with the instrument. The individual characteristics of every instrument are strongly dependent on the total ozone amount and the solar elevation. Therefore, a calibration procedure also has to take into account the ozone concentrations and the solar elevation to compensate for the effects of the individual characteristics and to provide comparable measurements. Given the variation of the ozone concentrations and the solar elevation, an individual cf has to be calculated for every measurement. Using a simplified version of the calibration procedure, which is presented in this study, can lessen this effort. Taking into account the relevant meteorological conditions for a measuring site, a single cf is calculated to compensate the individual characteristics of the instruments and therefore deliver comparable measurements with less effort.

  17. Calibration and investigation of infrared camera systems applying blackbody radiation

    Science.gov (United States)

    Hartmann, Juergen; Fischer, Joachim

    2001-03-01

    An experimental facility is presented, which allows calibration and detailed investigation of infrared camera systems. Various blackbodies operating in the temperature range from -60 degree(s)C up to 3000 degree(s)C serve as standard radiation sources, enabling calibration of camera systems in a wide temperature and spectral range with highest accuracy. Quantitative results and precise long-term investigations, especially in detecting climatic trends, require accurate traceability to the International Temperature Scale of 1990 (ITS-90). For the used blackbodies the traceability to ITS- 90 is either realized by standard platinum resistance thermometers (in the temperature range below 962 degree(s)C) or by absolute and relative radiometry (in the temperature range above 962 degree(s)C). This traceability is fundamental for implementation of quality assurance systems and realization of different standardizations, for example according ISO 9000. For investigation of the angular and the temperature resolution our set-up enables minimum resolvable (MRTD) and minimum detectable temperature difference (MDTD) measurements in the various temperature ranges. A collimator system may be used to image the MRTD and MDTD targets to infinity. As internal calibration of infrared camera systems critically depends on the temperature of the surrounding, the calibration and investigation of the cameras is performed in a climate box, which allows a detailed controlling of the environmental parameters like humidity and temperature. Experimental results obtained for different camera systems are presented and discussed.

  18. sistemas

    Directory of Open Access Journals (Sweden)

    Diego Alejandro Muñoz Gaviria

    2006-01-01

    Full Text Available El texto presentado a continuación, plantea en términos generales las principales posturas conceptuales del sociólogo alemán Niklas Luhmann sobre las ideas de Max Weber y su teoría de la acción social, y de Talcott Parsons y sus planteamientos en torno a la teoría de los sistemas sociales. Al final del escrito se hace especial énfasis en el rol protagónico que para Luhmann tienen las ciencias sociales y humanas en la autorreferencia del sistema social.

  19. Calibration of the radiation monitor onboard Akebono using Geant4

    Science.gov (United States)

    Asai, Keiko; Takashima, Takeshi; Koi, Tatsumi; Nagai, Tsugunobu

    Natural high-energy electrons and protons (keV-MeV) in the space contaminate the data re-ciprocally. In order to calibrate the energy ranges and to remove data contamination on the radiation monitor (RDM) onboard the Japanese satellite, Akebono (EXOS-D), the detector is investigated using the Geant4 simulation toolkit of computational particle tracing. The semi-polar orbiting Akebono, launched in February 1989, is active now. This satellite has been observed the space environment at altitudes of several thousands km. The RDM instrument onboard Akebono monitors energetic particles in the Earth's radiation belt and gives important data accumulated for about two solar cycles. The data from RDM are for electrons in three energy channels of 0.3 MeV, protons in three energy channels of ¿ 30 MeV, and alpha particles in one energy channels of 15-45 MeV. The energy ranges are however based on information of about 20 years ago so that the data seem to include some errors actuary. In addition, these data include contamination of electrons and protons reciprocally. Actuary it is noticed that the electron data are contaminated by the solar protons but unknown quantitative amount of the contamination. Therefore we need data calibration in order to correct the energy ranges and to remove data contamination. The Geant4 simulation gives information of trajectories of incident and secondary particles whose are interacted with materials. We examine the RDM monitor using the Geant4 simulation. We find from the results that relativistic electrons of MeV behave quite complicatedly because of particle-material interaction in the instrument. The results indicate that efficiencies of detection and contamination are dependent on energy. This study compares the electron data from Akebono RDM with the simultaneous observation of CRRES and tries to lead the values of correction for each of the energy channels.

  20. Guidelines for the Calibration of Routine Dosimetry Systems for use in Radiation Processing

    DEFF Research Database (Denmark)

    Sharpe, Peter; Miller, Arne

    A set of guidelines has been developed to assist in the calibration of routine dosimetry systems for use in industrial radiation processing plants. Topics covered include the calibration of equipment, the performance of calibration irradiations and the derivation of mathematical functions...

  1. Uses of Continuum Radiation in the AXAF Calibration

    Science.gov (United States)

    Kolodziejczak, J. J.; Austin, R. A.; Eisner, R. F.; ODell, S. L.; Sulkanen, M. E.; Swartz, D. A.; Tennant, A. F.; Weisskopf, M. C.; Zirnstein, G.; McDermott, W. C.

    1997-01-01

    X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

  2. Precise calibration of LIGO test mass actuators using photon radiation pressure

    CERN Document Server

    Goetz, E; Erickson, S; Savage, R L; González, G; Kawabe, K; Landry, M; Marka, S; O'Reilly, B; Riles, K; Sigg, D; Willems, P

    2009-01-01

    Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been implemented on the LIGO detectors. In this article, we discuss the inherent precision and accuracy of the LIGO photon calibrators and several improvements that have been developed to reduce the estimated voice coil actuator calibration uncertainties to less than 2 percent (1-sigma). These improvements include accounting for rotation-induced apparent length variations caused by interferometer and photon calibrator beam centering offsets, absolute laser power measurement using temperature-controlled InGaAs photodetectors mounted on integrating spheres and calibrated by NIST, minimizing errors induced by localized elastic defor...

  3. Effective radiation attenuation calibration for breast density: compression thickness influences and correction

    Directory of Open Access Journals (Sweden)

    Thomas Jerry A

    2010-11-01

    Full Text Available Abstract Background Calibrating mammograms to produce a standardized breast density measurement for breast cancer risk analysis requires an accurate spatial measure of the compressed breast thickness. Thickness inaccuracies due to the nominal system readout value and compression paddle orientation induce unacceptable errors in the calibration. Method A thickness correction was developed and evaluated using a fully specified two-component surrogate breast model. A previously developed calibration approach based on effective radiation attenuation coefficient measurements was used in the analysis. Water and oil were used to construct phantoms to replicate the deformable properties of the breast. Phantoms consisting of measured proportions of water and oil were used to estimate calibration errors without correction, evaluate the thickness correction, and investigate the reproducibility of the various calibration representations under compression thickness variations. Results The average thickness uncertainty due to compression paddle warp was characterized to within 0.5 mm. The relative calibration error was reduced to 7% from 48-68% with the correction. The normalized effective radiation attenuation coefficient (planar representation was reproducible under intra-sample compression thickness variations compared with calibrated volume measures. Conclusion Incorporating this thickness correction into the rigid breast tissue equivalent calibration method should improve the calibration accuracy of mammograms for risk assessments using the reproducible planar calibration measure.

  4. Calibrated, multiband radiometric measurements of the optical radiation from lightning

    Science.gov (United States)

    Quick, Mason G.

    Calibrated, multiband radiometric measurements of the optical radiation emitted by rocket-triggered lightning (RTL) have been made in the ultraviolet (UV, 200-360 nm), the visible and near infrared (VNIR, 400-1000 nm), and the long wave infrared (LWIR, 8-12 microm) spectral bands. Measurements were recorded from a distance of 198 m at the University of Florida International Center for Lightning Research and Testing (ICLRT) during the summers of 2011 and 2012. The ICLRT provided time-correlated measurements of the current at the base of the RTL channels. Following the onset of a return stroke, the dominant mechanism for the initial rise of the UV and VNIR waveforms was the geometrical growth of the channel in the field-of-view of the sensors. The UV emissions peaked about 0.7 micros after the current peak, with a peak spectral power emitted by the source per unit length of channel of 10 +/- 7 kW/(nm-m) in the UV. The VNIR emissions peaked 0.9 micros after the current peak, with a spectral power of at 7 +/- 4 kW/(nm-m). The LWIR emissions peaked 30-50 micros after the current peak, and the mean peak spectral power was 940 +/- 380 mW/(nm-m), a value that is about 4 orders of magnitude lower than the other spectral band emissions. In some returns strokes the LWIR peak coincides with a secondary maximum in the VNIR band that occurs during a steady decrease in channel current. Examples of the optical waveforms in each spectral band are shown as a function of time and are discussed in the context of the current measured at the channel base. Source power estimates in the VNIR band have a mean and standard deviation of 2.5 +/- 2.2 MW/m and are in excellent agreement with similar estimates of the emission from natural subsequent strokes that remain in a pre-existing channel which have a mean and standard deviation of 2.3 +/- 3.4 MW/m. The peak optical power emitted by RTL in the UV and VNIR bands are observed to be proportional to the square of the peak current at the

  5. Building 772 - CERN’s new calibration facility for radiation protection instruments is ready to go

    CERN Multimedia

    2014-01-01

    Building 772 is becoming the new home of CERN’s calibration facility for radiation protection instrumentation. The new laboratory in Prévessin will be a state-of-the-art calibration facility and the first of its kind in both France and Switzerland, offering a wide range of possibilities with respect to radiation fields and instrumentation.   New four-axis calibration bench for radiation protection instruments.   Civil engineering work started in November 2013 in Prévessin and Building 772 is now finished and ready for inauguration. CERN’s calibration facility was previously located in Building 172 in Meyrin. Although still very accurate, the technology used was becoming obsolete and needed replacement. “Having considered different options, the decision was taken to build a new facility fully designed and conceived to meet all international safety and technical requirements of such a laboratory,” says Pie...

  6. Calibrating a custom-made densitometer for radiation hardness measurements

    CERN Document Server

    Vaananen, Mika Petteri

    2017-01-01

    A custom-made densitometer was set up to be used in radiation hardness measurements of scintillating fibres. Also, a measurement setup to measure the minimal bending radius of scintillating fibres was designed and implemented.

  7. An alternative method for calibration of narrow band radiometer using a radiative transfer model

    Energy Technology Data Exchange (ETDEWEB)

    Salvador, J; Wolfram, E; D' Elia, R [Centro de Investigaciones en Laseres y Aplicaciones, CEILAP (CITEFA-CONICET), Juan B. de La Salle 4397 (B1603ALO), Villa Martelli, Buenos Aires (Argentina); Zamorano, F; Casiccia, C [Laboratorio de Ozono y Radiacion UV, Universidad de Magallanes, Punta Arenas (Chile) (Chile); Rosales, A [Universidad Nacional de la Patagonia San Juan Bosco, UNPSJB, Facultad de Ingenieria, Trelew (Argentina) (Argentina); Quel, E, E-mail: jsalvador@citefa.gov.ar [Universidad Nacional de la Patagonia Austral, Unidad Academica Rio Gallegos Avda. Lisandro de la Torre 1070 ciudad de Rio Gallegos-Sta Cruz (Argentina) (Argentina)

    2011-01-01

    The continual monitoring of solar UV radiation is one of the major objectives proposed by many atmosphere research groups. The purpose of this task is to determine the status and degree of progress over time of the anthropogenic composition perturbation of the atmosphere. Such changes affect the intensity of the UV solar radiation transmitted through the atmosphere that then interacts with living organisms and all materials, causing serious consequences in terms of human health and durability of materials that interact with this radiation. One of the many challenges that need to be faced to perform these measurements correctly is the maintenance of periodic calibrations of these instruments. Otherwise, damage caused by the UV radiation received will render any one calibration useless after the passage of some time. This requirement makes the usage of these instruments unattractive, and the lack of frequent calibration may lead to the loss of large amounts of acquired data. Motivated by this need to maintain calibration or, at least, know the degree of stability of instrumental behavior, we have developed a calibration methodology that uses the potential of radiative transfer models to model solar radiation with 5% accuracy or better relative to actual conditions. Voltage values in each radiometer channel involved in the calibration process are carefully selected from clear sky data. Thus, tables are constructed with voltage values corresponding to various atmospheric conditions for a given solar zenith angle. Then we model with a radiative transfer model using the same conditions as for the measurements to assemble sets of values for each zenith angle. The ratio of each group (measured and modeled) allows us to calculate the calibration coefficient value as a function of zenith angle as well as the cosine response presented by the radiometer. The calibration results obtained by this method were compared with those obtained with a Brewer MKIII SN 80 located in the

  8. Very high-accuracy calibration of radiation pattern and gain of a near-field probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Nielsen, Jeppe Majlund; Breinbjerg, Olav

    2014-01-01

    In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission of the Europ......In this paper, very high-accuracy calibration of the radiation pattern and gain of a near-field probe is described. An open-ended waveguide near-field probe has been used in a recent measurement of the C-band Synthetic Aperture Radar (SAR) Antenna Subsystem for the Sentinel 1 mission...

  9. Field calibration studies for ionisation chambers in mixed high-energy radiation fields.

    Science.gov (United States)

    Theis, C; Forkel-Wirth, D; Fuerstner, M; Mayer, S; Otto, Th; Roesler, S; Vincke, H

    2007-01-01

    The monitoring of ambient doses at work places around high-energy accelerators is a challenging task due the complexity of the mixed stray radiation fields encountered. At CERN, mainly Centronics IG5 high-pressure ionisation chambers are used to monitor radiation exposure in mixed fields. The monitors are calibrated in the operational quantity ambient dose equivalent H*(10) using standard, source-generated photon- and neutron fields. However, the relationship between ionisation chamber reading and ambient dose equivalent in a mixed high-energy radiation field can only be assessed if the spectral response to every component and the field composition is known. Therefore, comprehensive studies were performed at the CERN-EU high-energy reference field facility where the spectral fluence for each particle type has been assessed with Monte Carlo simulations. Moreover, studies have been performed in an accessible controlled radiation area in the vicinity of a beam loss point of CERN's proton synchrotron. The comparison of measurements and calculations has shown reasonable agreement for most exposure conditions. The results indicate that conventionally calibrated ionisation chambers can give satisfactory response in terms of ambient dose equivalent in stray radiation fields at high-energy accelerators in many cases. These studies are one step towards establishing a method of 'field calibration' of radiation protection instruments in which Monte Carlo simulations will be used to establish a correct correlation between the response of specific detectors to a given high-energy radiation field.

  10. Design and calibration of a novel transient radiative heat flux meter for a spacecraft thermal test

    Science.gov (United States)

    Sheng, Chunchen; Hu, Peng; Cheng, Xiaofang

    2016-06-01

    Radiative heat flux measurement is significantly important for a spacecraft thermal test. To satisfy the requirements of both high accuracy and fast response, a novel transient radiative heat flux meter was developed. Its thermal receiver consists of a central thermal receiver and two thermal guarded annular plates, which ensure the temperature distribution of the central thermal receiver to be uniform enough for reasonably applying lumped heat capacity method in a transient radiative heat flux measurement. This novel transient radiative heat flux meter design can also take accurate measurements regardless of spacecraft surface temperature and incident radiation spectrum. The measurement principle was elaborated and the coefficients were calibrated. Experimental results from testing a blackbody furnace and an Xenon lamp show that this novel transient radiative heat flux meter can be used to measure transient radiative heat flux up to 1400 W/m2 with high accuracy and the response time of less than 10 s.

  11. Secondary calibration laboratory for ionizing radiation laboratory accreitation program National Institute of Standards and Technology National Voluntary Laboratory Accreditation Program

    Energy Technology Data Exchange (ETDEWEB)

    Martin, P.R.

    1993-12-31

    This paper presents an overview of the procedures and requirements for accreditation under the Secondary Calibration Laboratory for Ionizing Radiation Program (SCLIR LAP). The requirements for a quality system, proficiency testing and the onsite assessment are discussed. The purpose of the accreditation program is to establish a network of secondary calibration laboratories that can provide calibrations traceable to the primary national standards.

  12. 16 CFR 1209.8 - Procedure for calibration of radiation instrumentation.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Procedure for calibration of radiation instrumentation. 1209.8 Section 1209.8 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.8 Procedure...

  13. Kinematic Fit for the Radiative Bhabha Calibration of BaBar's Electromagnetic Calorimeter

    OpenAIRE

    2000-01-01

    For the radiative Bhabha calibration of BaBar's electromagnetic calorimeter, the measured energy of a photon cluster is being compared with the energy obtained via a kinematic fit involving other quantities from that event. The details of the fitting algorithm are described in this note, together with its derivation and checks that ensure that the fitting routine is working properly.

  14. INFLUENCE OF SCATTERED NEUTRON RADIATION ON METROLOGICAL CHARACTERISTICS OF АТ140 NEUTRON CALIBRATION FACILITY

    Directory of Open Access Journals (Sweden)

    D. I. Komar

    2017-01-01

    Full Text Available Today facilities with collimated radiation field are widely used as reference in metrological support of devices for neutron radiation measurement. Neutron fields formed by radionuclide neutron sources. The aim of this research was to study characteristics of experimentally realized neutron fields geometries on АТ140 Neutron Calibration Facility using Monte Carlo method.For calibration, we put a device into neutron field with known flux density or ambient equivalent dose rate. We can form neutron beam from radionuclide fast-neutron source in different geometries. In containercollimator of АТ140 Neutron Calibration Facility we can install special inserts to gather fast-neutron geometry or thermal-neutron geometry. We need to consider neutron scattering from air and room’s walls. We can conduct measurements of neutron field characteristics in several points and get the other using Monte Carlo method.Thermal neutron collimator forms a beam from radionuclide source with a significant amount of neutrons with thermal energies. From found relationship between full neutron flux and distance to neutron source we see that inverse square law is violated. Scattered radiation contribution into total flux increases when we are moving away from neutron source and significantly influences neutron fields characteristics. While source is exposed in shadow-cone geometry neutron specter has pronounced thermal component from wall scattering.In this work, we examined main geometry types used to acquire reference neutron radiation using radionuclide sources. We developed Monte Carlo model for 238Pu-Be neutron source and АТ140 Neutron Calibration Facility’s container-collimator. We have shown the most significant neutron energy distribution factor to be scattered radiation from room’s walls. It leads to significant changes of neutron radiation specter at a distance from the source. When planning location, and installing the facility we should consider

  15. Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yidong, E-mail: yidongyang@med.miami.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 and Department of Radiation Oncology, University of Miami School of Medicine, Miami, Florida 33136 (United States); Wang, Ken Kang-Hsin; Wong, John W. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231 (United States); Eslami, Sohrab; Iordachita, Iulian I. [Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Patterson, Michael S. [Juravinski Cancer Centre and Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario L8S4K1 (Canada)

    2015-04-15

    Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3

  16. New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers

    Science.gov (United States)

    Anhalt, K.; Zelenjuk, A.; Taubert, D. R.; Keawprasert, T.; Hartmann, J.

    2009-02-01

    The paper describes the new experimental setup assembled at the PTB for the absolute spectral responsivity measurement of radiation thermometers. The concept of this setup is to measure the relative spectral responsivity of the radiation thermometer using the conventional monochromator-based spectral comparator facility also used for the calibration of filter radiometers. The absolute spectral responsivity is subsequently measured at one wavelength, supplied by the radiation of a diode laser, using the new setup. The radiation of the diode laser is guided with an optical fiber into an integrating sphere source that is equipped with an aperture of absolutely known area. The spectral radiance of this integrating sphere source is determined via the spectral irradiance measured by a trap detector with an absolutely calibrated spectral responsivity traceable to the primary detector standard of the PTB, the cryogenic radiometer. First results of the spectral responsivity calibration of the radiation thermometer LP3 are presented, and a provisional uncertainty budget of the absolute spectral responsivity is given.

  17. Broadband Outdoor Radiometer Calibration Process for the Atmospheric Radiation Measurement Program

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.

  18. Determination of scattered gamma radiation in the calibration of environmental dose rate meters

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Hedemann Jensen, P.

    1992-01-01

    Practical free-field and shadow-shield calibration techniques using a variety of environmental dose rate meters were studied, and experimental and theoretical determinations were made of the contribution of scattered photons to the air kerma rate from certificated Cs-137, Co-60 and Ra-226 gamma...... the detector responses. Insignificant differences of the order of 1 % between the results for the two geometries were found both experimentally and theoretically. It is thus concluded that the scattered radiation from surrounding buildings farther away than around 15 m from a calibration set-up contributes...... negligibly to the detector response relative to that from ground and air. Shadow-shield measurements were used to deduce the contribution to the response from the scattered radiation in free-field geometries and the experimentally obtained results were found to agree agree extremely well with those...

  19. Continuous calibration of a vacuum ultraviolet system from 65 to 125 nm by a cascade arc and comparison with the calibrated line radiation of a hollow cathode.

    Science.gov (United States)

    Frost, R M; Awakowicz, P

    1997-03-20

    A high-power stationary helium cascade arc has been developed as a standard source for continuum radiation in the VUV spectral range from 65 to 125 nm. The calibration of the VUV system response was based on the calculated and measured continuum radiation of a 2-mmphi pure He arc. Diagnostics of the arc plasma in partial thermal equilibrium yielded the electron density and the temperature that were inserted in the calculations of the continuous radiation. The results were compared with the helium, argon, and krypton radiation lines of a high-current hollow cathode lamp. This lamp was built according to the construction drawings of a hollow cathode, which was calibrated by means of the electron synchrotron radiation at the Physikalisch Technische Bundesanstalt Berlin.

  20. Calibration of GOES-derived solar radiation data using a distributed network of surface measurements in Florida, USA

    Science.gov (United States)

    Sumner, David M.; Pathak, Chandra S.; Mecikalski, John R.; Paech, Simon J.; Wu, Qinglong; Sangoyomi, Taiye; Babcock, Roger W.; Walton, Raymond

    2008-01-01

    Solar radiation data are critically important for the estimation of evapotranspiration. Analysis of visible-channel data derived from Geostationary Operational Environmental Satellites (GOES) using radiative transfer modeling has been used to produce spatially- and temporally-distributed datasets of solar radiation. An extensive network of (pyranometer) surface measurements of solar radiation in the State of Florida has allowed refined calibration of a GOES-derived daily integrated radiation data product. This refinement of radiation data allowed for corrections of satellite sensor drift, satellite generational change, and consideration of the highly-variable cloudy conditions that are typical of Florida. To aid in calibration of a GOES-derived radiation product, solar radiation data for the period 1995–2004 from 58 field stations that are located throughout the State were compiled. The GOES radiation product was calibrated by way of a three-step process: 1) comparison with ground-based pyranometer measurements on clear reference days, 2) correcting for a bias related to cloud cover, and 3) deriving month-by-month bias correction factors. Pre-calibration results indicated good model performance, with a station-averaged model error of 2.2 MJ m–2 day–1 (13 percent). Calibration reduced errors to 1.7 MJ m–2 day–1 (10 percent) and also removed time- and cloudiness-related biases. The final dataset has been used to produce Statewide evapotranspiration estimates.

  1. CR-39 and Lexan calibrated as low-LET radiation dosimeter, for three Mexican irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Tavera, L. [Instituto Mexicano del Petroleo, Eje Central Lazaro Cardenas No 152, Mexico DF 07730 (Mexico)]. E-mail: mltavera@imp.mx; Balcazar, M. [Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, Mexico DF 11801 (Mexico); Matamoros, H. [Instituto Mexicano del Petroleo, Eje Central Lazaro Cardenas No 152, Mexico DF 07730 (Mexico); Carrasco, H. [Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, Mexico DF 11801 (Mexico)

    2005-11-15

    An experimental calibration of two common nuclear track detectors, CR-39 and Lexan, for gamma and electrons radiation, was performed using various irradiation facilities. The dose response was obtained as a function of two parameters, the bulk etch rate and the UV absorbance for a wide dose range from 10 to 1000 kGy. The bulk etch rate sensitivity, for gamma and electrons, in CR-39 detector is higher than for Lexan detector. Lexan has a well-defined UV absorbance spectrum, but presents saturation for doses higher than 500 kGy, the same saturation characteristic is observed for the corresponding bulk etch rate response. For electron and gamma radiation, CR-39 shows a good response for doses from 10 kGy up to 1000 kGy, where data fit well an exponential curve for electrons and a lineal curve for gamma radiation.

  2. Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter

    CERN Document Server

    Maestro, P; Allison, P S; Bagliesi, M G; Beatty, J J; Bigongiari, G; Boyle, P J; Brandt, T J; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Jeon, J A; Kim, K C; Lee, J K; Lee, M H; Lutz, L; Marrocchesi, P S; Malinine, A; Minnick, S; Mognet, S I; Nam, S; Nutter, S; Park, H; Park, I H; Park, N H; Seo, E S; Sina, R; Swordy, S; Wakely, S P; Wu, J; Yang, J; Yoon, Y S; Zei, R; Zinn, S Y

    2010-01-01

    The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicraynuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.

  3. Nuclear reactor pulse calibration using a CdZnTe electro-optic radiation detector

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Kyle A., E-mail: knelson1@ksu.edu [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Geuther, Jeffrey A. [TRIGA Mark II Nuclear Reactor, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Neihart, James L.; Riedel, Todd A. [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Rojeski, Ronald A. [Nanometrics, Inc., 1550 Buckeye Drive, Milpitas, CA 95035 (United States); Saddler, Jeffrey L. [TRIGA Mark II Nuclear Reactor, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States); Schmidt, Aaron J.; McGregor, Douglas S. [S.M.A.R.T. Laboratory, Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS 66506 (United States)

    2012-07-15

    A CdZnTe electro-optic radiation detector was used to calibrate nuclear reactor pulses. The standard configuration of the Pockels cell has collimated light passing through an optically transparent CdZnTe crystal located between crossed polarizers. The transmitted light was focused onto an IR sensitive photodiode. Calibrations of reactor pulses were performed using the CdZnTe Pockels cell by measuring the change in the photodiode current, repeated 10 times for each set of reactor pulses, set between 1.00 and 2.50 dollars in 0.50 increments of reactivity. - Highlights: Black-Right-Pointing-Pointer We demonstrated the first use of an electro-optic device to trace reactor pulses in real-time. Black-Right-Pointing-Pointer We examined the changes in photodiode current for different reactivity insertions. Black-Right-Pointing-Pointer Created a linear best fit line from the data set to predict peak pulse powers.

  4. Calibration of low-frequency radio telescopes using the galactic background radiation

    Science.gov (United States)

    Dulk, G. A.; Erickson, W. C.; Manning, R.; Bougeret, J.-L.

    2001-01-01

    We consider the calibration of flux densities of radio bursts from decametric to kilometric wavelengths using ground-based and space-based data. The method we derive is applicable to low-frequency radio telescopes where galactic background radiation is the principal contribution to system temperature. It can be particularly useful for telescopes of low angular resolution observing spectra of radio bursts from the Sun and the planets because absolute calibration of these telescopes is very difficult with conventional techniques. Here we apply the method to observations from about 7 to 47 MHz that were made on the ground with the Bruny Island Radio Spectrometer located in Tasmania, Australia, and those from about 20 kHz to 13.8 MHz were made with the radio experiment WAVES on the WIND spacecraft. The spectrum of the galactic background radiation from 30 MHz has been carefully measured with low-resolution telescopes, starting more than a decade ago. We use this known spectrum to calibrate both BIRS and WAVES on an absolute scale. The accuracy we achieve is about a factor of two, whereas the flux densities of solar and planetary radio sources vary by many orders of magnitude. Our method permits inter-calibration of ground-based and space-based observations, and allows corrections to be made for instrumental uncertainties on both radio experiments. In addition, on the ground, it allows the spectra to be corrected for ionospheric absorption and partial ground reflections. As an application we show the spectrum of a solar type III burst observed from 47 MHz to 20 kHz. Its flux density was largest, S~ 10-17 W m-2 Hz-1, at about 3 MHz, while at 60 kHz and at 47 MHz it was lower by a factor of about 300.

  5. Evaluation of the Earth Radiation Budget Experiment (ERBE) shortwave channel's stability using in-flight calibration sources

    Science.gov (United States)

    Gibson, Michael A.; Lee, Robert B., III; Thomas, Susan

    1992-01-01

    The Earth Radiation Budget Experiment (ERBE) radiometers were designed to make absolute measurements of the incoming solar, earth-reflected solar, and earth-emitted fluxes for investigations of the earth's climate system. Thermistor bolometers were the sensors used for the ERBE scanning radiometric package. Each thermistor bolometer package consisted of three narrow field of view broadband radiometric channels measuring shortwave, longwave, and total (0.2 micron to 50 microns) radiation. The in-flight calibration facilities include Mirror Attenuator Mosaics, shortwave internal calibration source, and internal blackbody sources to monitor the long-term responsivity of the radiometers. This paper describes the in-flight calibration facilities, the calibration data reduction techniques, and the results from the in-flight shortwave channel calibrations. The results indicate that the ERBE shortwave detectors were stable to within +/- 1 percent for up to five years of flight operation.

  6. Analysis and calibration of stage axial vibration for synchrotron radiation nanoscale computed tomography.

    Science.gov (United States)

    Fu, Jian; Li, Chen; Liu, Zhenzhong

    2015-10-01

    Synchrotron radiation nanoscale computed tomography (SR nano-CT) is a powerful analysis tool and can be used to perform chemical identification, mapping, or speciation of carbon and other elements together with X-ray fluorescence and X-ray absorption near edge structure (XANES) imaging. In practical applications, there are often challenges for SR nano-CT due to the misaligned geometry caused by the sample stage axial vibration. It occurs quite frequently because of experimental constraints from the mechanical error of manufacturing and assembly and the thermal expansion during the time-consuming scanning. The axial vibration will lead to the structure overlap among neighboring layers and degrade imaging results by imposing artifacts into the nano-CT images. It becomes worse for samples with complicated axial structure. In this work, we analyze the influence of axial vibration on nano-CT image by partial derivative. Then, an axial vibration calibration method for SR nano-CT is developed and investigated. It is based on the cross correlation of plane integral curves of the sample at different view angles. This work comprises a numerical study of the method and its experimental verification using a dataset measured with the full-field transmission X-ray microscope nano-CT setup at the beamline 4W1A of the Beijing Synchrotron Radiation Facility. The results demonstrate that the presented method can handle the stage axial vibration. It can work for random axial vibration and needs neither calibration phantom nor additional calibration scanning. It will be helpful for the development and application of synchrotron radiation nano-CT systems.

  7. Antarctic network of lamp-calibrated multichannel radiometers for continuous ozone and uv radiation data

    Directory of Open Access Journals (Sweden)

    A. Redondas

    2008-02-01

    Full Text Available Three NILU-UV multichannel radiometers have been installed in 1999 at the Argentinian sites of Ushuaia (54S, Marambio (64S and Belgrano-II (77S in order to continuously monitor UV radiation, photosynthetically active radiation and total ozone. The measurements were established by INM, Spain in collaboration with FMI, Finland, DNA-IAA, Argentina and CADIC, Argentina to observe and characterize the spatial and temporal evolution of ozone and ultraviolet radiation in the Antarctic region. Special attention has been given to the quality control and quality assurance of the measurements under harsh climatological conditions. The ozone and UV time series of 2000–2006 were calibrated using a polynomial fit for lamp measurements performed every second week all year round. The gaps in these data are minimal, with almost no data missing, and the data products are available from http://www.polarvortex.org in near real time. The data products include the erythemally-weighted UV, UVB and UVA radiation, photosynthetically active radiation (PAR, total ozone (O3 and a cloud parameter (CLT. For UV data, dose rates as well as daily doses are available; from these the maximum measured UV indices (UVI, during 2000–2006, were 12.0, 9.7 and 8.1 at Ushuaia, Marambio and Belgrano-II, respectively.

  8. Calibration of a PIXE system for analysis of environmental aerosols; Calibracion de un sistema PIXE para analisis de aerosoles ambientales

    Energy Technology Data Exchange (ETDEWEB)

    Aldape, F.; Diaz, R.V.; Anguiano, G.; Flores M, J. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-04-15

    The results of the calibration of the PIXE system for analysis of environmental aerosols in the CNM is presented. The system was calibrated in order to lead to the project study of environmental aerosols using PIXE from the qualitative dimension to the quantitative one. Part of this work it was carried out in collaboration with the expert of the IAEA Dr. D. Crumpton. The calibration of the system it was achieved bombarding thin targets of well-known composition with protons of 2.5 MeV. Using this technique it was determined the absolute elementary concentration in samples of atmospheric aerosols. As an example the calculation of the lead concentration in one of them whose result was of 662 {+-} 49 ng m{sup -3} is presented. This value agrees with the measurements made in the Crocker Nuclear Lab of the UCD. Its are also discussed the reproducibility and precision of the used technique. (Author)

  9. Local Adaptive Calibration of the GLASS Surface Incident Shortwave Radiation Product Using Smoothing Spline

    Science.gov (United States)

    Zhang, X.; Liang, S.; Wang, G.

    2015-12-01

    Incident solar radiation (ISR) over the Earth's surface plays an important role in determining the Earth's climate and environment. Generally, can be obtained from direct measurements, remotely sensed data, or reanalysis and general circulation models (GCMs) data. Each type of product has advantages and limitations: the surface direct measurements provide accurate but sparse spatial coverage, whereas other global products may have large uncertainties. Ground measurements have been normally used for validation and occasionally calibration, but transforming their "true values" spatially to improve the satellite products is still a new and challenging topic. In this study, an improved thin-plate smoothing spline approach is presented to locally "calibrate" the Global LAnd Surface Satellite (GLASS) ISR product using the reconstructed ISR data from surface meteorological measurements. The influences of surface elevation on ISR estimation was also considered in the proposed method. The point-based surface reconstructed ISR was used as the response variable, and the GLASS ISR product and the surface elevation data at the corresponding locations as explanatory variables to train the thin plate spline model. We evaluated the performance of the approach using the cross-validation method at both daily and monthly time scales over China. We also evaluated estimated ISR based on the thin-plate spline method using independent ground measurements at 10 sites from the Coordinated Enhanced Observation Network (CEON). These validation results indicated that the thin plate smoothing spline method can be effectively used for calibrating satellite derived ISR products using ground measurements to achieve better accuracy.

  10. The Aurora radiation-hydrodynamical simulations of reionization: calibration and first results

    Science.gov (United States)

    Pawlik, Andreas H.; Rahmati, Alireza; Schaye, Joop; Jeon, Myoungwon; Dalla Vecchia, Claudio

    2017-04-01

    We introduce a new suite of radiation-hydrodynamical simulations of galaxy formation and reionization called Aurora. The Aurora simulations make use of a spatially adaptive radiative transfer technique that lets us accurately capture the small-scale structure in the gas at the resolution of the hydrodynamics, in cosmological volumes. In addition to ionizing radiation, Aurora includes galactic winds driven by star formation and the enrichment of the universe with metals synthesized in the stars. Our reference simulation uses 2 × 5123 dark matter and gas particles in a box of size 25 h-1 comoving Mpc with a force softening scale of at most 0.28 h-1 kpc. It is accompanied by simulations in larger and smaller boxes and at higher and lower resolution, employing up to 2 × 10243 particles, to investigate numerical convergence. All simulations are calibrated to yield simulated star formation rate functions in close agreement with observational constraints at redshift z = 7 and to achieve reionization at z ≈ 8.3, which is consistent with the observed optical depth to reionization. We focus on the design and calibration of the simulations and present some first results. The median stellar metallicities of low-mass galaxies at z = 6 are consistent with the metallicities of dwarf galaxies in the Local Group, which are believed to have formed most of their stars at high redshifts. After reionization, the mean photoionization rate decreases systematically with increasing resolution. This coincides with a systematic increase in the abundance of neutral hydrogen absorbers in the intergalactic medium.

  11. The Aurora radiation-hydrodynamical simulations of reionization: calibration and first results

    CERN Document Server

    Pawlik, Andreas H; Schaye, Joop; Jeon, Myoungwon; Vecchia, Claudio Dalla

    2016-01-01

    We introduce a new suite of radiation-hydrodynamical simulations of galaxy formation and reionization called Aurora. The Aurora simulations make use of a spatially adaptive radiative transfer technique that lets us accurately capture the small-scale structure in the gas at the resolution of the hydrodynamics, in cosmological volumes. In addition to ionizing radiation, Aurora includes galactic winds driven by star formation and the enrichment of the universe with metals synthesized in the stars. Our reference simulation uses 2x512^3 dark matter and gas particles in a box of size 25 comoving Mpc/h with a force softening scale of at most 0.28 kpc/h. It is accompanied by simulations in larger and smaller boxes and at higher and lower resolution, employing up to 2x1024^3 particles, to investigate numerical convergence. All simulations are calibrated to yield simulated star formation rate (SFR) functions in close agreement with observational constraints at redshift z = 7 and to achieve reionization at z = 8.3, whic...

  12. The ENEA calibration service for ionising radiations; Il centro di taratura per le radiazioni ionizzanti di Bologna. Parte 1: Fotoni

    Energy Technology Data Exchange (ETDEWEB)

    Monteventi, F.; Sermenghi, I. [ENEA, Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1999-07-01

    The report describes all the facilities available at the the service of the ENEA Calibration Service for Ionising Radiations at Bologna (Italy). It gives a detailed description of all equipment qualified for photon fields metrology including the secondary standards and the calibration procedures performed for radiation monitoring devices and dosemeters. [Italian] Il presente lavoro descrive i servizi e le attivita' del Centro di Taratura dell'ENEA di Bologna, in particolare delle attrezzature qualificate per la metrologia fotonica, dei campioni di misura e delle procedure adottate per la taratura degli strumenti e dei dosimetri.

  13. Directional Degradation of Spectralon Diffuser Under Ionizing Radiation for Calibration of Space-Based Sensors

    Science.gov (United States)

    Georgiev, G. T.; Butler, J. J.; Kowalewski, M. G.; Ding, L.

    2012-01-01

    Assessment of the effect of Vacuum Ultra Violet (VUV) irradiation on the Bidirectional Reflectance Distribution Function (BRDF) of Spectralon is presented in this paper. The sample was a 99% white Spectralon calibration standard irradiated with VUV source positioned at 60o off the irradiation direction for a total of 20 hours. The BRDF before and after VUV irradiation was measured and compared at number of wavelengths in the UV, VIS and IR. Non-isotropic directional degradation of Spectralon diffuser under ionizing radiation was detected at different BRDF measurement geometries primarily at UV spectral range. The 8o directional/hemispherical reflectance of the same sample was also measured and compared from 200nm to 2500nm. Index Terms BRDF, Reflectance, Multiangular, Spectralon, Remote Sensing

  14. The geometric calibration of cone-beam imaging and delivery systems in radiation therapy

    CERN Document Server

    Matsinos, E; Kaissl, Wolfgang; Matsinos, Evangelos

    2006-01-01

    We propose a method to achieve the geometric calibration of cone-beam imaging and delivery systems in radiation therapy; our approach applies to devices where an X-ray source and a flat-panel detector, facing each other, move in circular orbits around the irradiated object. In order to extract the parameters of the geometry from the data, we use a light needle phantom which is easy to manufacture. A model with ten free parameters (spatial lengths and distortion angles) has been put forth to describe the geometry and the mechanical imperfections of the units being calibrated; a few additional parameters are introduced to account for residual effects (small effects which lie beyond our model). The values of the model parameters are determined from one complete scan of the needle phantom via a robust optimisation scheme. The application of this method to two sets of five counterclockwise (ccw) and five clockwise (cw) scans yielded consistent and reproducible results. A number of differences have been observed be...

  15. Robot tracking system improvements and visual calibration of orbiter position for radiator inspection

    Science.gov (United States)

    Tonkay, Gregory

    1990-01-01

    The following separate topics are addressed: (1) improving a robotic tracking system; and (2) providing insights into orbiter position calibration for radiator inspection. The objective of the tracking system project was to provide the capability to track moving targets more accurately by adjusting parameters in the control system and implementing a predictive algorithm. A computer model was developed to emulate the tracking system. Using this model as a test bed, a self-tuning algorithm was developed to tune the system gains. The model yielded important findings concerning factors that affect the gains. The self-tuning algorithms will provide the concepts to write a program to automatically tune the gains in the real system. The section concerning orbiter position calibration provides a comparison to previous work that had been performed for plant growth. It provided the conceptualized routines required to visually determine the orbiter position and orientation. Furthermore, it identified the types of information which are required to flow between the robot controller and the vision system.

  16. Field calibration of PADC track etch detectors for local neutron dosimetry in man using different radiation qualities

    Energy Technology Data Exchange (ETDEWEB)

    Haelg, Roger A., E-mail: rhaelg@phys.ethz.ch [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Besserer, Juergen [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Boschung, Markus; Mayer, Sabine [Division for Radiation Safety and Security, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Clasie, Benjamin [Department of Radiation Oncology, Massachusetts General Hospital, 30 Fruit Street, Boston, MA 02114 (United States); Kry, Stephen F. [Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Schneider, Uwe [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 204, CH-8057 Zurich (Switzerland)

    2012-12-01

    In order to quantify the dose from neutrons to a patient for contemporary radiation treatment techniques, measurements inside phantoms, representing the patient, are necessary. Published reports on neutron dose measurements cover measurements performed free in air or on the surface of phantoms and the doses are expressed in terms of personal dose equivalent or ambient dose equivalent. This study focuses on measurements of local neutron doses inside a radiotherapy phantom and presents a field calibration procedure for PADC track etch detectors. An initial absolute calibration factor in terms of H{sub p}(10) for personal dosimetry is converted into neutron dose equivalent and additional calibration factors are derived to account for the spectral changes in the neutron fluence for different radiation therapy beam qualities and depths in the phantom. The neutron spectra used for the calculation of the calibration factors are determined in different depths by Monte Carlo simulations for the investigated radiation qualities. These spectra are used together with the energy dependent response function of the PADC detectors to account for the spectral changes in the neutron fluence. The resulting total calibration factors are 0.76 for a photon beam (in- and out-of-field), 1.00 (in-field) and 0.84 (out-of-field) for an active proton beam and 1.05 (in-field) and 0.91 (out-of-field) for a passive proton beam, respectively. The uncertainty for neutron dose measurements using this field calibration method is less than 40%. The extended calibration procedure presented in this work showed that it is possible to use PADC track etch detectors for measurements of local neutron dose equivalent inside anthropomorphic phantoms by accounting for spectral changes in the neutron fluence.

  17. Böhm extrapolation chamber: Study of its behavior in beta radiation fields at the Calibration Laboratory of IPEN

    Science.gov (United States)

    Antonio, Patrícia L.; Xavier, Marcos; Caldas, Linda V. E.

    2014-11-01

    The Calibration Laboratory (LCI) at the Instituto de Pesquisas Energéticas e Nucleares (IPEN) is going to establish a Böhm extrapolation chamber as a primary standard system for the dosimetry and calibration of beta radiation sources and detectors. This chamber was already tested in beta radiation beams with an aluminized Mylar entrance window, and now, it was characterized with an original Hostaphan entrance window. A comparison between the results of the extrapolation chamber with the two entrance windows was performed. The results showed that this extrapolation chamber presents the same effectiveness in beta radiation fields as a primary standard system with both entrance windows, showing that any one of them may be utilized.

  18. Evaluation of the occupational dose reduction after automation process for calibration of gamma radiation monitors; Avaliacao da reducao da dose ocupacional apos automacao do processo de calibracao de monitores de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Iremar Alves da; Potiens, Maria da P.A., E-mail: iremarjr@gmail.com, E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2013-11-01

    In this study, it was evaluated the occupational dose of calibration technicians responsible for monitor calibration of gamma radiation in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (IPEN-LCI), Sp, Brazil in your calibration activities before and after the automation of the process monitor calibration gamma be completed. Various measures of occupational dose values were taken inside the room calibration and the control room of radiators allowing calculate and show the occupational dose values in these environments during a full calibration of a monitor gamma radiation, showing the advantage of automation process, with decrease in dose and time calibration. (author)

  19. A time-calibrated species tree of Crocodylia reveals a recent radiation of the true crocodiles.

    Science.gov (United States)

    Oaks, Jamie R

    2011-11-01

    True crocodiles (Crocodylus) are the most broadly distributed, ecologically diverse, and species-rich crocodylian genus, comprising about half of extant crocodylian diversity and exhibiting a circumtropical distribution. Crocodylus traditionally has been viewed as an ancient group of morphologically conserved species that originated in Africa prior to continental breakup. In this study, these long-held notions about the temporal and geographic origin of Crocodylus are tested using DNA sequence data of 10 loci from 76 individuals representing all 23 crocodylian species. I infer a time-calibrated species tree of all Crocodylia and estimate the spatial pattern of diversification within Crocodylus. For the first time, a fully resolved phylogenetic estimate of all Crocodylia is well-supported. The results overturn traditional views of the evolution of Crocodylus by demonstrating that the true crocodiles are not "living-fossils" that originated in Africa. Rather, Crocodylus originated from an ancestor in the tropics of the Late Miocene Indo-Pacific, and rapidly radiated and dispersed around the globe during a period marked by mass extinctions of fellow crocodylians. The findings also reveal more diversity within the genus than is recognized by current taxonomy.

  20. Automated System of Area Radiation Measurement (ASARM); Sistema Automatizado de Medicion de Radiacion de Area (SAMRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez G, J., E-mail: jaime.hernandez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  1. The Cherenkov Radiation for Non-Trivial Systems; La Radiacion Cherenkov en Sistemas No Triviales

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.

    2002-07-01

    The charge pathways and the dielectric properties of the medium are two essential aspects to be considered in the study of the emission of Cherenkov radiation. We described the evolution of the Cherenkov wavefront when the charges follow circular or helical pathways. Also we derive expressions for the refractive Index in different transparent media (solid, liquid or gas), focusing our attention on optically active plasmas. The optical analogies between the plasma and the birefringent crystals is studied in detail. Finally, we list some examples of plasmas, which can be considered emitters of Cherenkov radiation. (Author) 52 refs.

  2. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, H.T. II; Taylor, A.R. Jr. [Center for Devices and Radiological Health, Rockville, MD (United States)

    1993-12-31

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. This paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory.

  3. NOAA Climate Data Record (CDR) of Intersatellite Calibrated Clear-Sky High Resolution Infrared Radiation Sounder (HIRS) Channel 12 Brightness Temperature Version 3

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The High-Resolution Infrared Radiation Sounder (HIRS) of intersatellite calibrated channel 12 brightness temperature (TB) product is a gridded global monthly time...

  4. Radiation condition in computerized tomography (CT): determination and calibration of dosemeters; Condicoes de radiacao em tomografia computadorizada (TC): determinacao e calibracao de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Adrade, L.C.; Peixoto, J.G.P., E-mail: lucio-andrade@hotmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    RQT is the standard for radiation conditions in computed tomography . It simulates a beam unrelieved of a CT scanner . The camera pencil ionization dosimeter is used in CT. The LNMRI become known characterization of RQT radiation conditions and the secondary standard calibration for type pencil ionisation chambers in its lab. The obtained beam has the characteristics required by IEC 61267. The results of the calibration presented combined uncertainty expanded to 95.45% from 2.22% . (author)

  5. Community Radiative Transfer Model for Inter-Satellites Calibration and Verification

    Science.gov (United States)

    Liu, Q.; Nalli, N. R.; Ignatov, A.; Garrett, K.; Chen, Y.; Weng, F.; Boukabara, S. A.; van Delst, P. F.; Groff, D. N.; Collard, A.; Joseph, E.; Morris, V. R.; Minnett, P. J.

    2014-12-01

    Developed at the Joint Center for Satellite Data Assimilation, the Community Radiative Transfer Model (CRTM) [1], operationally supports satellite radiance assimilation for weather forecasting. The CRTM also supports JPSS/NPP and GOES-R missions [2] for instrument calibration, validation, monitoring long-term trending, and satellite retrieved products [3]. The CRTM is used daily at the NOAA NCEP to quantify the biases and standard deviations between radiance simulations and satellite radiance measurements in a time series and angular dependency. The purposes of monitoring the data assimilation system are to ensure the proper performance of the assimilation system and to diagnose problems with the system for future improvements. The CRTM is a very useful tool for cross-sensor verifications. Using the double difference method, it can remove the biases caused by slight differences in spectral response and geometric angles between measurements of the two instruments. The CRTM is particularly useful to reduce the difference between instruments for climate studies [4]. In this study, we will carry out the assessment of the Suomi National Polar-orbiting Partnership (SNPP) [5] Cross-track Infrared Sounder (CrIS) data [6], Advanced Technology Microwave Sounder (ATMS) data, and data for Visible Infrared Imaging Radiometer Suite (VIIRS) [7][8] thermal emissive bands. We use dedicated radiosondes and surface data acquired from NOAA Aerosols and Ocean Science Expeditions (AEROSE) [9]. The high quality radiosondes were launched when Suomi NPP flew over NOAA Ship Ronald H. Brown situated in the tropical Atlantic Ocean. The atmospheric data include profiles of temperature, water vapor, and ozone, as well as total aerosol optical depths. The surface data includes air temperature and humidity at 2 meters, skin temperature (Marine Atmospheric Emitted Radiance Interferometer, M-AERI [10]), surface temperature, and surface wind vector. [1] Liu, Q., and F. Weng, 2006: JAS [2] Liu, Q

  6. Calibration of solid state nuclear track detectors at high energy ion beams for cosmic radiation measurements: HAMLET results

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, J., E-mail: julianna.szabo@energia.mta.hu [Hungarian Academy of Sciences, Centre for Energy Research, Konkoly Thege Miklos ut 29-33, 1525 Budapest 114, P.O. Box 49 (Hungary); Palfalvi, J.K. [Hungarian Academy of Sciences, Centre for Energy Research, Konkoly Thege Miklos ut 29-33, 1525 Budapest 114, P.O. Box 49 (Hungary)

    2012-12-01

    The MATROSHKA experiments and the related HAMLET project funded by the European Commission aimed to study the dose burden of the crew working on the International Space Station (ISS). During these experiments a human phantom equipped with several thousands of radiation detectors was exposed to cosmic rays inside and outside the ISS. Besides the measurements realized in Earth orbit, the HAMLET project included also a ground-based program of calibration and intercomparison of the different detectors applied by the participating groups using high-energy ion beams. The Space Dosimetry Group of the Centre for Energy Research (formerly Atomic Energy Research Institute) participated in these experiments with passive solid state nuclear track detectors (SSNTDs). The paper presents the results of the calibration experiments performed in the years 2008-2011 at the Heavy Ion Medical Accelerator (HIMAC) of the National Institute of Radiological Sciences (NIRS), Chiba, Japan. The data obtained serve as update and improvement for the previous calibration curves which are necessary for the evaluation of the SSNTDs exposed in unknown space radiation fields.

  7. Evaluation of Multiple-Sampling Function used with a Microtek flatbed scanner for Radiation Dosimetry Calibration of EBT2 Film

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Liyun [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China); Ho, Sheng-Yow [Department of Nursing, Chang Jung Christian University, Tainan 71101, Taiwan (China); Department of Radiation Oncology, Chi Mei Medical Center, Liouying, Tainan 73657, Taiwan (China); Ding, Hueisch-Jy [Department of Medical Imaging and Radiological Sciences, I-Shou University, Kaohsiung 82445, Taiwan (China); Hwang, Ing-Ming [Department of Medical Imaging and Radiology, Shu Zen College of Medicine and Management, Kaohsiung 82144, Taiwan (China); Chen, Pang-Yu, E-mail: pangyuchen@yahoo.com.tw [Department of Radiation Oncology, Sinlau Christian Hospital, Tainan 70142, Taiwan (China); Lee, Tsair-Fwu, E-mail: tflee@kuas.edu.tw [Medical Physics and Informatics Laboratory, Department of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan (China)

    2016-10-01

    The radiochromic EBT2 film is a widely used quality assurance device for radiation therapy. This study evaluated the film calibration performance of the multiple-sampling function, a function of the ScanWizard Pro scanning software provided by the manufacturer, when used with Microtek 9800XL plus (9800XL{sup +}) flatbed scanner. By using the PDD method, each one of the eight EBT2 films, four delivered by 290 monitor unit (MU) and four by 88 MU via 6-MV photon beams, was tightly sandwiched in a 30{sup 3}-cm{sup 3} water equivalent polystyrene phantom prior to irradiation. Before and after irradiation, all films were scanned using the Microtek 9800XL{sup +} scanner with five different modes of the multiple-sampling function, which could generate the image with the averaged result of multiple-sampling. The net optical densities (netOD) on the beam central axis of film were assigned to corresponding depth doses for calibration. For each sampling mode with either delivered MU, the depth-dose uncertainty of a single film from repeated scans and that of a single scan of the four films were analyzed. Finally, the calibration error and the combined calibration uncertainty between film determined depth-doses and delivered depth-doses were calculated and evaluated for each sampling mode. All standard deviations and the calibration error were demonstrated to be unrelated to the number of sampling lines. The calibration error of the 2-line and 16-line mode was within 3 cGy and better than that of the other modes. The combined uncertainty of the 2-line mode was the lowest, which was generally less than 6 cGy except for the delivered dose around 100 cGy. The evaluation described herein revealed that the EBT2 film calibrated with the 2-line mode has relatively lower error, scanning time and combined uncertianty. Therefore, it is recommended for routine EBT2 film calibration and verification of treatment plans.

  8. Fourth IRMF comparison of calibrations of portable gamma-ray dose- rate monitors 2001-2002 Ionising radiation

    CERN Document Server

    Lewis, V E

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a fourth comparison of calibrations of gamma-ray dose-rate monitors in which fifteen establishments in the UK participated. The exercise involved the circulation of three gamma-ray monitors for calibration in the fields produced using sup 1 sup 3 sup 7 Cs, sup 2 sup 4 sup 1 Am and sup 6 sup 0 Co. The instruments used were an Electra with MC 20 probe, a Mini-Instruments Mini-rad 1000 and a Siemens electronic personal dosemeter Mk 2 (EPD). The responses relative to 'true' dose equivalent rate were calculated by the individual participants and submitted to the for analysis along with details of the facilities and fields employed. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments. However, the participants' treatment of uncertainties needs improvement and demonstrates a need for guidance in this area.

  9. Development of a heliostat facility for solar-radiation-based calibration of earth observing sensors

    Science.gov (United States)

    Kuester, Michele A.; Czapla-Myers, Jeffrey; Kaptchen, Paul; Good, William; Lin, Tony; To, Raymund; Biggar, Stuart; Thome, Kurtis

    2008-08-01

    A new heliostat facility at Ball Aerospace and Technologies Corporation (BATC) in Boulder, CO will allow the use of the sun as the source in the calibration of earth observing sensors. The solar spectrum is the basic energy source for such instruments; therefore it is advantageous to perform initial ground radiometric calibrations using the sun. Using this method for preflight radiometric calibration reduces uncertainties caused by the spectral mismatch between the preflight and in-flight calibration, especially in the case in which a solar diffuser is the in-flight calibration method. This method also reduces stray light concerns as the instrument diffuser is measured in situ with the same radiance level it sees on orbit. This paper presents the design of a heliostat test facility which tracks the sun and directs the solar beam into a thermal vacuum chamber, allowing the instrument under test to be kept in a safe, clean and controllable environment. Design considerations that affect the uniformity and transmission of the system are discussed. The opto-mechanical logistics of creating a heliostat that will deliver a 13-inch solar beam into a thermal vacuum chamber are also presented. This facility is currently under construction at BATC and is expected to be operational by the end of 2008.

  10. New in-flight calibration adjustment of the Nimbus 6 and 7 earth radiation budget wide field of view radiometers

    Science.gov (United States)

    Kyle, H. L.; House, F. B.; Ardanuy, P. E.; Jacobowitz, H.; Maschhoff, R. H.; Hickey, J. R.

    1984-01-01

    In-flight calibration adjustments are developed to process data obtained from the wide-field-of-view channels of Nimbus-6 and Nimbus-7 after the failure of the Nimbus-7 longwave scanner on June 22, 1980. The sensor characteristics are investigated; the satellite environment is examined in detail; and algorithms are constructed to correct for long-term sensor-response changes, on/off-cycle thermal transients, and filter-dome absorption of longwave radiation. Data and results are presented in graphs and tables, including comparisons of the old and new algorithms.

  11. Biological dosimetry of ionizing radiation: Evaluation of the dose with cytogenetic methodologies by the construction of calibration curves

    Science.gov (United States)

    Zafiropoulos, Demetre; Facco, E.; Sarchiapone, Lucia

    2016-09-01

    In case of a radiation accident, it is well known that in the absence of physical dosimetry biological dosimetry based on cytogenetic methods is a unique tool to estimate individual absorbed dose. Moreover, even when physical dosimetry indicates an overexposure, scoring chromosome aberrations (dicentrics and rings) in human peripheral blood lymphocytes (PBLs) at metaphase is presently the most widely used method to confirm dose assessment. The analysis of dicentrics and rings in PBLs after Giemsa staining of metaphase cells is considered the most valid assay for radiation injury. This work shows that applying the fluorescence in situ hybridization (FISH) technique, using telomeric/centromeric peptide nucleic acid (PNA) probes in metaphase chromosomes for radiation dosimetry, could become a fast scoring, reliable and precise method for biological dosimetry after accidental radiation exposures. In both in vitro methods described above, lymphocyte stimulation is needed, and this limits the application in radiation emergency medicine where speed is considered to be a high priority. Using premature chromosome condensation (PCC), irradiated human PBLs (non-stimulated) were fused with mitotic CHO cells, and the yield of excess PCC fragments in Giemsa stained cells was scored. To score dicentrics and rings under PCC conditions, the necessary centromere and telomere detection of the chromosomes was obtained using FISH and specific PNA probes. Of course, a prerequisite for dose assessment in all cases is a dose-effect calibration curve. This work illustrates the various methods used; dose response calibration curves, with 95% confidence limits used to estimate dose uncertainties, have been constructed for conventional metaphase analysis and FISH. We also compare the dose-response curve constructed after scoring of dicentrics and rings using PCC combined with FISH and PNA probes. Also reported are dose response curves showing scored dicentrics and rings per cell, combining

  12. Technology for radiation efficiency measurement of high-power halogen tungsten lamp used in calibration of high-energy laser energy meter.

    Science.gov (United States)

    Wei, Ji Feng; Hu, Xiao Yang; Sun, Li Qun; Zhang, Kai; Chang, Yan

    2015-03-20

    The calibration method using a high-power halogen tungsten lamp as a calibration source has many advantages such as strong equivalence and high power, so it is very fit for the calibration of high-energy laser energy meters. However, high-power halogen tungsten lamps after power-off still reserve much residual energy and continually radiate energy, which is difficult to be measured. Two measuring systems were found to solve the problems. One system is composed of an integrating sphere and two optical spectrometers, which can accurately characterize the radiative spectra and power-time variation of the halogen tungsten lamp. This measuring system was then calibrated using a normal halogen tungsten lamp made of the same material as the high-power halogen tungsten lamp. In this way, the radiation efficiency of the halogen tungsten lamp after power-off can be quantitatively measured. In the other measuring system, a wide-spectrum power meter was installed far away from the halogen tungsten lamp; thus, the lamp can be regarded as a point light source. The radiation efficiency of residual energy from the halogen tungsten lamp was computed on the basis of geometrical relations. The results show that the halogen tungsten lamp's radiation efficiency was improved with power-on time but did not change under constant power-on time/energy. All the tested halogen tungsten lamps reached 89.3% of radiation efficiency at 50 s after power-on. After power-off, the residual energy in the halogen tungsten lamp gradually dropped to less than 10% of the initial radiation power, and the radiation efficiency changed with time. The final total radiation energy was decided by the halogen tungsten lamp's radiation efficiency, the radiation efficiency of residual energy, and the total power consumption. The measuring uncertainty of total radiation energy was 2.4% (here, the confidence factor is two).

  13. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    Science.gov (United States)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  14. Gray-Tone Lithography Implementation of Drexhage's Method for Calibrating Radiative and Nonradiative Decay Constants of Fluorophores

    CERN Document Server

    Kwadrin, Andrej; 10.1021/jp3048423

    2013-01-01

    We present a straightforward method to realize non-planar dielectric structures with a controlled height profile for use in calibration of fluorophores. Calibration of fluorescence quantum efficiency and intrinsic radiative and nonradiative decay rates of emitters is possible by using changes in the local density of optical states, provided one can control the emitter-surface distance with nanometer accuracy. We realize a method that is accurate yet fast to implement. We fabricate PMMA wedges (4 mm x 4 mm x 2 \\mu m) by gray-tone UV-lithography of Shipley S1813G2. Its applicability as dielectric spacer is demonstrated in Drexhage experiments for three different emitters in the visible and near-infrared wavelength regime. The decay-rate dependence of the fluorescent state of emitters on the distance to a silver mirror is observed and compared to calculations based on the local density of states. Quantitative values for (non)radiative decay rates and quantum efficiencies are extracted. Furthermore, we discuss ho...

  15. Note: Calibration of EBT3 radiochromic film for measuring solar ultraviolet radiation.

    Science.gov (United States)

    Chun, S L; Yu, P K N

    2014-10-01

    Solar (UVA + UVB) exposure was assessed using the Gafchromic EBT3 film. The coloration change was represented by the net reflective optical density (Net ROD). Through calibrations against a UV-tube lamp, operational relationships were obtained between Net ROD and the (UVA + UVB) exposures (in J cm(-2) or J m(-2)). The useful range was from ∼0.2 to ∼30 J cm(-2). The uniformity of UV irradiation was crucial for an accurate calibration. For solar exposures ranging from 2 to 11 J cm(-2), the predicted Net ROD agreed with the recorded values within 9%, while the predicted exposures agreed with the recorded values within 15%.

  16. Note: Calibration of EBT3 radiochromic film for measuring solar ultraviolet radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chun, S. L. [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong (Hong Kong); Yu, P. K. N., E-mail: peter.yu@cityu.edu.hk [Department of Physics and Materials Science, City University of Hong Kong, Kowloon Tong (Hong Kong); State Key Laboratory in Marine Pollution, City University of Hong Kong, Kowloon Tong (Hong Kong)

    2014-10-01

    Solar (UVA + UVB) exposure was assessed using the Gafchromic EBT3 film. The coloration change was represented by the net reflective optical density (Net ROD). Through calibrations against a UV-tube lamp, operational relationships were obtained between Net ROD and the (UVA + UVB) exposures (in J cm⁻²p or J m⁻²). The useful range was from ~0.2 to ~30 J cm⁻². The uniformity of UV irradiation was crucial for an accurate calibration. For solar exposures ranging from 2 to 11 J cm⁻², the predicted Net ROD agreed with the recorded values within 9%, while the predicted exposures agreed with the recorded values within 15%.

  17. Montagem e acurácia de um sistema experimental de pesagem para calibração de sensores de umidade do solo Assembling and accuracy of an experimental weighing system for calibration of soil moisture sensors

    Directory of Open Access Journals (Sweden)

    Ricardo Martins Santos

    2006-12-01

    Full Text Available O presente trabalho descreve os procedimentos de desenvolvimento e teste de um sistema de pesagem de grande capacidade para utilização em gravimetria como método padrão de calibração de sensores de umidade do solo. O trabalho foi desenvolvido no Laboratório de Irrigação e Drenagem, Centro de Ciências Agrárias e Ambientais da Universidade Federal da Bahia, campus de Cruz das Almas (12º40'S, 39º30'W, BA. O princípio de funcionamento do sistema de pesagem baseia-se no seu componente principal, a célula de carga. Utilizou-se uma célula de carga do tipo flexão, de capacidade 60 kg e sensibilidade de 2 mV/V, quando submetida à carga máxima. A calibração foi realizada por meio de massas-padrão de 1, 5, 10 e 20 kg em sete ciclos de carregamento e descarregamento. O modelo de calibração encontrado foi do tipo linear (r² = 0,999 e os erros de repetibilidade, histerese e linearidade foram da ordem de 0,119, 0,068 e 0,009% do final de escala (FE, respectivamente. Os limites do erro de acurácia, que representa o desempenho geral do sistema, foram ±0,083% de FE. O sistema de pesagem foi considerado adequado, do ponto de vista de funcionalidade e desempenho, para calibração em condições controladas, de sensores de umidade do tipo sonda de capacitância, utilizando-se amostras indeformadas de solo. O custo final do sistema foi estimado em R$ 1.800,00 (US$ 766,00.This work describes the development and testing of a large-capacity weighing system for calibration of soil moisture sensors in which the gravimetric method is taken as the standard one. The experiment was conducted at the Laboratório de Irrigação e Drenagem, Centro de Ciências Agrárias e Ambientais da Universidade Federal da Bahia, town of Cruz das Almas (12º40'S, 39º30'W, State of Bahia, Brazil. The main component of the system was a 60-kg load cell with a 2-mV/V sensibility when submitted to the maximum load. In the calibration process standard weights of 1, 5

  18. Calibration of a Plastic Classification System with the CCW Model; Calibracion de un Sistema de Clasification de Plasticos segun el Modelo CCW

    Energy Technology Data Exchange (ETDEWEB)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-07-01

    This document describes the calibration of a plastic Classification system with the CCW model (Classification by Quaternions built Wavelet Coefficients). The method is applied to spectra of plastics usually present in domestic wastes. Obtained results are showed. (Author) 16 refs.

  19. Real-time airborne gamma-ray background estimation using NASVD with MLE and radiation transport for calibration

    Energy Technology Data Exchange (ETDEWEB)

    Kulisek, J.A., E-mail: Jonathan.Kulisek@pnnl.gov; Schweppe, J.E.; Stave, S.C.; Bernacki, B.E.; Jordan, D.V.; Stewart, T.N.; Seifert, C.E.; Kernan, W.J.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this challenge, we have developed a new technique for real-time estimation of background gamma radiation from aerial measurements without the need for human analyst intervention. The method can be calibrated using radiation transport simulations along with data from previous flights over areas for which the isotopic composition need not be known. Over the examined measured and simulated data sets, the method generated accurate background estimates even in the presence of a strong, {sup 60}Co source. The potential to track large and abrupt changes in background spectral shape and magnitude was demonstrated. The method can be implemented fairly easily in most modern computing languages and environments.

  20. Real-time airborne gamma-ray background estimation using NASVD with MLE and radiation transport for calibration

    Science.gov (United States)

    Kulisek, J. A.; Schweppe, J. E.; Stave, S. C.; Bernacki, B. E.; Jordan, D. V.; Stewart, T. N.; Seifert, C. E.; Kernan, W. J.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this challenge, we have developed a new technique for real-time estimation of background gamma radiation from aerial measurements without the need for human analyst intervention. The method can be calibrated using radiation transport simulations along with data from previous flights over areas for which the isotopic composition need not be known. Over the examined measured and simulated data sets, the method generated accurate background estimates even in the presence of a strong, 60Co source. The potential to track large and abrupt changes in background spectral shape and magnitude was demonstrated. The method can be implemented fairly easily in most modern computing languages and environments.

  1. ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL

    Science.gov (United States)

    Dekker, P. R.; van der Ham, E. W. M.

    2008-06-01

    In the first half of 2005, Nederlands Meetinstituut Van Swinden Laboratorium B.V. (NMi VSL) redesigned their facilities for radiation thermometry in a new laboratory building and an opportunity arose to implement new measurement methods. The new facility is used for ITS-90 realization and dissemination in the temperature range from - 50 °C to 3,000 °C. A study was performed to compare a silver-point realization with a fixed-point blackbody radiator (FP-BBR) to a sodium heat-pipe blackbody radiator (HP-BBR) traceable via a HTSPRT to a contact thermometry silver point. It was found that the fixed-point realization transfer to the sodium heat pipe results in an uncertainty from 0.2 K to 2.4 K for the ITS-90 over the temperature range from 961.78 °C to 3,000 °C.

  2. Calibration of three-dimensional ultrasound images for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Bouchet, Lionel G. [Department of Neurological Surgery, University of Florida, Gainesville, FL (United States). E-mail: bouchet at neurosurgery.ufl.edu; Bova, Francis J.; Friedman, William A. [Department of Neurological Surgery, University of Florida, Gainesville, FL (United States); Meeks, Sanford L.; Buatti, John M. [Division of Radiation Oncology, University of Iowa, Iowa City, IA (United States); Goodchild, Gordon [Medtronic Surgical Navigation Technologies, Broomfield, CO (United States)

    2001-02-01

    A new technique of patient positioning for radiotherapy/radiosurgery of extracranial tumours using three-dimensional (3D) ultrasound images has been developed. The ultrasound probe position is tracked within the treatment room via infrared light emitting diodes (IRLEDs) attached to the probe. In order to retrieve the corresponding room position of the ultrasound image, we developed an initial ultrasound probe calibration technique for both 2D and 3D ultrasound systems. This technique is based on knowledge of points in both room and image coordinates. We first tested the performance of three algorithms in retrieving geometrical transformations using synthetic data with different noise levels. Closed form solution algorithms (singular value decomposition and Horn's quaternion algorithms) were shown to outperform the Hooke and Jeeves iterative algorithm in both speed and accuracy. Furthermore, these simulations show that for a random noise level of 2.5, 5, 7.5 and 10 mm, the number of points required for a transformation accuracy better than 1 mm is 25, 100, 200 and 500 points respectively. Finally, we verified the tracking accuracy of this system using a specially designed ultrasound phantom. Since ultrasound images have a high noise level, we designed an ultrasound phantom that provides a large number of points for the calibration. This tissue equivalent phantom is made of nylon wires, and its room position is optically tracked using IRLEDs. By obtaining multiple images through the nylon wires, the calibration technique uses an average of 300 points for 3D ultrasound volumes and 200 for 2D ultrasound images, and its stability is very good for both rotation (standard deviation: 0.4 deg.) and translation (standard deviation: 0.3 mm) transformations. After this initial calibration procedure, the position of any voxel in the ultrasound image volume can be determined in world space, thereby allowing real-time image guidance of therapeutic procedures. Finally, the

  3. Monte-Carlo investigation of radiation beam quality of the CRNA neutron irradiator for calibration purposes

    Energy Technology Data Exchange (ETDEWEB)

    Mazrou, Hakim, E-mail: mazrou_h@crna.d [Centre de Recherche Nucleaire d' Alger (CRNA), 02 Boulevard Frantz, Fanon, B.P. 399, Alger-RP 16000 (Algeria); Sidahmed, Tassadit [Centre de Recherche Nucleaire d' Alger (CRNA), 02 Boulevard Frantz, Fanon, B.P. 399, Alger-RP 16000 (Algeria); Allab, Malika [Faculte de Physique, Universite des Sciences et de la Technologie de Houari-Boumediene (USTHB), 16111, Alger (Algeria)

    2010-10-15

    An irradiation system has been acquired by the Nuclear Research Center of Algiers (CRNA) to provide neutron references for metrology and dosimetry purposes. It consists of an {sup 241}Am-Be radionuclide source of 185 GBq (5 Ci) activity inside a cylindrical steel-enveloped polyethylene container with radially positioned beam channel. Because of its composition, filled with hydrogenous material, which is not recommended by ISO standards, we expect large changes in the physical quantities of primary importance of the source compared to a free-field situation. Thus, the main goal of the present work is to fully characterize neutron field of such special delivered set-up. This was conducted by both extensive Monte-Carlo calculations and experimental measurements obtained by using BF{sub 3} and {sup 3}He based neutron area dosimeters. Effects of each component present in the bunker facility of the Algerian Secondary Standard Dosimetry Laboratory (SSDL) on the energy neutron spectrum have been investigated by simulating four irradiation configurations and comparison to the ISO spectrum has been performed. The ambient dose equivalent rate was determined based upon a correct estimate of the mean fluence to ambient dose equivalent conversion factors at different irradiations positions by means of a 3-D transport code MCNP5. Finally, according to practical requirements established for calibration purposes an optimal irradiation position has been suggested to the SSDL staff to perform, in appropriate manner, their routine calibrations.

  4. Effect of the Scattering Radiation in Air and Two Type of Slap Phantom between PMMA and the ISO Water Phantom for Personal Dosimeters Calibration

    Science.gov (United States)

    Kamwang, N.; Rungseesumran, T.; Saengchantr, D.; Monthonwattana, S.; Pungkun, V.

    2017-06-01

    The calibration of personal dosimeter to determine the quantities of the personal dose equivalent, Hp(d), is required to be placed on a suitable phantom in order to provide a reasonable approximation to the radiation backscattering properties as equivalent as part of body. The dosimeter which is worn on the trunk usually calibrated with slap phantom which recommended in ICRU 47 with dimension of 30 cm (w) x 30 cm (h) x 15 cm (t) PMMA slab phantom to achieve uniformity in calibration procedures, on the other hand the International Organization for Standardization (ISO), ISO 4037-3, proposed the ISO water slap phantom, with PMMA walls, same dimension but different wall thickness (front wall 2.5 mm and other side wall 10 mm thick) and fill with water. However, some laboratories are still calibrating a personal dosimeter in air in term of ambient dose equivalent, H*(d). This research study the effect of the scattering radiation in two type of those slap phantoms and in air, to calibrate two type of OSL (XA and LA) and electronic personal dosimeters. The X-ray and Cs-137 radiation field with the energy range from 33 to 662 keV were used. The results of this study will be discussed.

  5. Calibration and start-up of the system of radiotherapy extract image-guided; Calibracion y puesta en marcha del sistema de radioterpia guiada por la imagen exactrac

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, I.; Perez Vara, C.; Prieto Villacorta, M.

    2013-07-01

    The accuracy in the administration of external radiotherapy treatments may be increased through the use of guidance systems by image. Constitute a particular case x-rays teams independent of the treatment unit. Among them is the ExacTrac (Brainlab) system. The objective of this work is to briefly introduce the procedure followed in the calibration and implementation of such a system. (Author)

  6. Real-Time Airborne Gamma-Ray Background Estimation Using NASVD with MLE and Radiation Transport for Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Kulisek, Jonathan A.; Schweppe, John E.; Stave, Sean C.; Bernacki, Bruce E.; Jordan, David V.; Stewart, Trevor N.; Seifert, Carolyn E.; Kernan, Warnick J.

    2015-06-01

    Helicopter-mounted gamma-ray detectors can provide law enforcement officials the means to quickly and accurately detect, identify, and locate radiological threats over a wide geographical area. The ability to accurately distinguish radiological threat-generated gamma-ray signatures from background gamma radiation in real time is essential in order to realize this potential. This problem is non-trivial, especially in urban environments for which the background may change very rapidly during flight. This exacerbates the challenge of estimating background due to the poor counting statistics inherent in real-time airborne gamma-ray spectroscopy measurements. To address this, we have developed a new technique for real-time estimation of background gamma radiation from aerial measurements. This method is built upon on the noise-adjusted singular value decomposition (NASVD) technique that was previously developed for estimating the potassium (K), uranium (U), and thorium (T) concentrations in soil post-flight. The method can be calibrated using K, U, and T spectra determined from radiation transport simulations along with basis functions, which may be determined empirically by applying maximum likelihood estimation (MLE) to previously measured airborne gamma-ray spectra. The method was applied to both measured and simulated airborne gamma-ray spectra, with and without man-made radiological source injections. Compared to schemes based on simple averaging, this technique was less sensitive to background contamination from the injected man-made sources and may be particularly useful when the gamma-ray background frequently changes during the course of the flight.

  7. 长波红外高光谱成像光谱仪的辐射定标%Study of Radiation Calibration for LWIR Hyperspectral Imager Spectrometer

    Institute of Scientific and Technical Information of China (English)

    袁小春; 杨智雄; 余春超; 郑为建; 雷正刚; 严敏

    2015-01-01

    Infrared radiometric calibration is of critical importance for information quantification of remote sensing of environment in infrared spectrum. In the quantitative analysis, the calibration of the measured spectra is very imporant. LWIR Interferometric Hyperspectral imager Spectrometer Prototype(CHIPED-I) is developed for studying Radiation Calibration. Two-point linear calibration method is carried out for the spectrometer by using blackbody respectively. Firstly, relative intensity is converted to the absolute radiation lightness of the object. Then, radiation intensity of the object is converted into the brightness temperature spectrum by the method of brightness temperature. The result indicats that such method of Radiation Calibration calibration is very good , which is of significance to the further analysis of atmospheric transmission and the retrieval of the concentration of infrared active gas in atmosphere.%红外辐射定标是红外遥感信息定量化的关键技术,对所测光谱进行定标是定量分析中的重要环节。采用自行研制长波红外高光谱成像光谱仪原理实验装置(简称 CHIPED-I)进行验证,用黑体对实验装置进行了两点线性定标,将测量的相对强度转化成目标的绝对辐射亮度谱,采用亮温法算出标定后的亮温光谱。结果表明,这种辐射定标方法用于长波红外高光谱成像光谱仪方法可行,这对进一步分析大气透过率和反演大气中红外活性气体浓度具有实际意义。

  8. Second Order Harmonics Suppression With Glass Filters for Synchrotron UV Radiation Calibration Measurement

    CERN Document Server

    Burattini, E; Gambicorti, L; Malvezzi, F; Marcelli, A; Monti, F; Pace, E

    2005-01-01

    This development is the latest result of the cooperation between the National Laboratories of Frascati and the Department of Astronomy and Space Science of the University of Florence to improve the capabilities of the existing DXR-2 beam line at the DAΦNE-LIGHT laboratories. This collaboration has assessed a new facility in order to characterize optics and sensors in a wide spectral range (ranging from VUV to IR). Previous measurements [1] have highlighted some limitations in the present setup, as higher signal levels due to the diffracted radiation of the grating in the second order have to be removed to allow an accurate detection. In this work a glass filter is used to remove such spurious signal present in the spectral region with λ > 360 nm. The characteristics of the filter and its application to the optical system used to measure the sensitivity of a diamond-based photoconductor have been discussed.

  9. Development of monoenergetic electron beam sources for radiation-instrument calibration

    Science.gov (United States)

    Soares, C. G.; Dick, C. E.; Pruitt, J. S.; Sparrow, J. H.

    1985-05-01

    Accelerator-produced electron beams are being studied for use in obtaining the response of beta-particle dosimetry instrumenta- tion as a function of electron energy. The NBS 4 MV Van de Graaff and 500 kV cascaded rectifier accelerators are being used to generate electron beams from 200 keV to 2.5 MeV. A device capable of scanning the electron beam in two dimensions over an area large enough to cover radiation-survey instruments uniformly is attached to the beam-handling system of each accelerator. The scanned beam exits from vacuum through a 16 cm 2 window consisting of either 25 μm Kapton (for energies below 500 keV) or 100 μm aluminum. The electron beams produced have been characterized in terms of (1) spatial distribution, (2) energy spectrum, and (3) absorbed dose to plastic. Spatial distributions were determined using film, while spectra were measured using a 5 mm-deep Si surface barrier detector. An extrapolation chamber is being used for beam standardization in terms of absorbed dose to plastic.

  10. Development of monoenergetic electron beam sources for radiation-instrument calibration

    Energy Technology Data Exchange (ETDEWEB)

    Soares, C.G.; Dick, C.E.; Pruitt, J.S.; Sparrow, J.H.

    1985-05-15

    Accelerator-produced electron beams are being studied for use in obtaining the response of beta-particle dosimetry instrumentation as a function of electron energy. The NBS 4 MV Van de Graaff and 500 kV cascaded rectifier accelerators are being used to generate electron beams from 200 keV to 2.5 MeV. A device capable of scanning the electron beam in two dimensions over an area large enough to cover radiation-survey instruments uniformly is attached to the beam-handling system of each accelerator. The scanned beam exits from vacuum through a 16 cm/sup 2/ window consisting of either 25 ..mu..m Kapton (for energies below 500 keV) or 100 ..mu..m aluminum. The electron beams produced have been characterized in terms of (1) spatial distribution, (2) energy spectrum, and (3) absorbed dose to plastic. Spatial distributions were determined using film, while spectra were measured using a 5 mm-deep Si surface barrier detector. An extrapolation chamber is being used for beam standardization in terms of absorbed dose to plastic. (orig.).

  11. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS; Sistema para calibracion de instrumentos de medicion de rayos X (CIR-X) aplicando el PGCS

    Energy Technology Data Exchange (ETDEWEB)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: egg@nuclear.inin.mx

    2007-07-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  12. Radiation decomposition of alcohols and chloro phenols in micellar systems; Descomposicion por irradiacion de alcoholes y clorofenoles en sistemas micelares

    Energy Technology Data Exchange (ETDEWEB)

    Moreno A, J

    1998-12-31

    The effect of surfactants on the radiation decomposition yield of alcohols and chloro phenols has been studied with gamma doses of 2, 3, and 5 KGy. These compounds were used as typical pollutants in waste water, and the effect of the water solubility, chemical structure, and the nature of the surfactant, anionic or cationic, was studied. The results show that anionic surfactant like sodium dodecylsulfate (SDS), improve the radiation decomposition yield of ortho-chloro phenol, while cationic surfactant like cetyl trimethylammonium chloride (CTAC), improve the radiation decomposition yield of butyl alcohol. A similar behavior is expected for those alcohols with water solubility close to the studied ones. Surfactant concentrations below critical micellar concentration (CMC), inhibited radiation decomposition for both types of alcohols. However radiation decomposition yield increased when surfactant concentrations were bigger than the CMC. Aromatic alcohols decomposition was more marked than for linear alcohols decomposition. On a mixture of alcohols and chloro phenols in aqueous solution the radiation decomposition yield decreased with increasing surfactant concentration. Nevertheless, there were competitive reactions between the alcohols, surfactants dimers, hydroxyl radical and other reactive species formed on water radiolysis, producing a catalytic positive effect in the decomposition of alcohols. Chemical structure and the number of carbons were not important factors in the radiation decomposition. When an alcohol like ortho-chloro phenol contained an additional chlorine atom, the decomposition of this compound was almost constant. In conclusion the micellar effect depend on both, the nature of the surfactant (anionic or cationic) and the chemical structure of the alcohols. The results of this study are useful for wastewater treatment plants based on the oxidant effect of the hydroxyl radical, like in advanced oxidation processes, or in combined treatment such as

  13. Entropy generation in tube and fin radiating systems; Geracao de entropia em sistemas radiantes de tubos aletados

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcio Bueno dos; Saboya, Sergio Mourao [Instituto Nacional de Pesquisas Espaciais (INPE), S Jose dos Campos, SP (Brazil). Lab. de Integracao e Testes]. E-mail: bueno@lit.inpe.br; saboya@mec.ita.cta.br

    1997-07-01

    The entropy generation minimization method is applied to tube and fin radiative systems. The mathematical modeling of the systems lead to a non-linear integro-differential systems of equations, which is solved numerically. The entropy generation in the fin is computed. This is obtained as result of the thermal analysis of the system which gives the fin temperature distributions and the radiative heat transfer rates. Examples of optimized design are considered and discussed. (author)

  14. Calibration of the RSS-131 high efficiency ionization chamber for radiation dose monitoring during plasma experiments conducted on plasma focus device

    Science.gov (United States)

    Szewczak, Kamil; Jednoróg, Sławomir

    2014-10-01

    Plasma research poses a radiation hazard. Due to the program of deuterium plasma research using the PF-1000 device, it is an intensive source of neutrons (up to 1011 n · pulse -1) with energy of 2,45 MeV and ionizing electromagnetic radiation with a broad energy spectrum. Both types of radiation are mostly emitted in ultra-short pulses (˜100 ns). The aim of this work was to test and calibrate the RSS-131 radiometer for its application in measurements of ultra-short electromagnetic radiation pulses with broad energy spectrum emitted during PF-1000 discharge. In addition, the results of raw measurements performed in the control room are presented.

  15. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190.

    Science.gov (United States)

    Lin, Pei-Jan P; Schueler, Beth A; Balter, Stephen; Strauss, Keith J; Wunderle, Kevin A; LaFrance, M Terry; Kim, Don-Soo; Behrman, Richard H; Shepard, S Jeff; Bercha, Ishtiaq H

    2015-12-01

    Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, "dose-area-product" (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term "DAP-meter" has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the "Accuracy and Calibration of Integrated Radiation Output Indicators" which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical "meter." To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

  16. Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Pei-Jan P., E-mail: Pei-Jan.Lin@vcuhealth.org [Virginia Commonwealth University Medical Center, Richmond, Virginia 23298 (United States); Schueler, Beth A. [Mayo Clinic, Rochester, Minnesota 55905 (United States); Balter, Stephen [Columbia University Medical Center, New York, New York 10032 (United States); Strauss, Keith J. [Children’s Hospital Medical Center, Cincinnati, Ohio 45229 (United States); Wunderle, Kevin A. [Cleveland Clinic Foundation, Cleveland, Ohio 44195 (United States); LaFrance, M. Terry [Baystate Health Systems, Inc., Springfield, Massachusetts 01199 (United States); Kim, Don-Soo [Children’s Hospital Boston, Boston, Massachusetts 02115 (United States); Behrman, Richard H. [Boston University Medical Center, Boston, Massachusetts 02118 (United States); Shepard, S. Jeff [University of Texas MD Anderson Cancer Center, Houston, Texas 77096 (United States); Bercha, Ishtiaq H. [Children’s Hospital Colorado, Aurora, Colorado 80045 (United States)

    2015-12-15

    Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

  17. CERES Top-of-Atmosphere Earth Radiation Budget Climate Data Record: Accounting for in-Orbit Changes in Instrument Calibration

    Directory of Open Access Journals (Sweden)

    Norman G. Loeb

    2016-02-01

    Full Text Available The Clouds and the Earth’s Radiant Energy System (CERES project provides observations of Earth’s radiation budget using measurements from CERES instruments onboard the Terra, Aqua and Suomi National Polar-orbiting Partnership (S-NPP satellites. As the objective is to create a long-term climate data record, it is necessary to periodically reprocess the data in order to incorporate the latest calibration changes and algorithm improvements. Here, we focus on the improvements and validation of CERES Terra and Aqua radiances in Edition 4, which are used to generate higher-level climate data products. Onboard sources indicate that the total (TOT channel response to longwave (LW radiation has increased relative to the start of the missions by 0.4% to 1%. In the shortwave (SW, the sensor response change ranges from −0.4% to 0.6%. To account for in-orbit changes in SW spectral response function (SRF, direct nadir radiance comparisons between instrument pairs on the same satellite are made and an improved wavelength dependent degradation model is used to adjust the SRF of the instrument operating in a rotating azimuth plane scan mode. After applying SRF corrections independently to CERES Terra and Aqua, monthly variations amongst these instruments are highly correlated and the standard deviation in the difference of monthly anomalies is 0.2 Wm−2 for ocean and 0.3 Wm−2 for land/desert. Additionally, trends in CERES Terra and Aqua monthly anomalies are consistent to 0.21 Wm−2 per decade for ocean and 0.31 Wm−2 per decade for land/desert. In the LW, adjustments to the TOT channel SRF are made to ensure that removal of the contribution from the SW portion of the TOT channel with SW channel radiance measurements during daytime is consistent throughout the mission. Accordingly, anomalies in day–night LW difference in Edition 4 are more consistent compared to Edition 3, particularly for the Aqua land/desert case.

  18. Laboratory radiation calibration method of Hadamard transform imaging spectrometer%Hadamard变换成像光谱仪实验室辐射定标方法

    Institute of Scientific and Technical Information of China (English)

    白军科; 刘学斌; 闫鹏; 胡炳樑

    2013-01-01

      Hadamard变换成像光谱仪采用多通道探测数字变换技术实现光谱成像.主要介绍了基于数字微镜阵列器件的Hadamard变换成像光谱仪的工作原理与仪器结构,研究设计了一套适用于该Hadamard变换成像光谱仪的实验室辐射定标方案.用远距点光源光路进行CMOS探测器像元响应不均匀性修正,获得相对定标精度达到4.6%;采用太阳模拟光源和均匀平行光路,用光谱辐射度计实现标准辐射亮度的传递进行光谱辐射定标,绝对定标精度达到8.92%.通过实物成像,Hadamard变换成像光谱仪的实验室辐射定标方法精确、实用.%Hadamard transform imaging spectrometer is a multi -channel detection digital transform spectrometer detection technology. The spectromter used this technology to achieving spectral imaging. Based on the digital micromirror array device of the Hadamard transform spectrometer working principles and the instrument, a series of precision laboratory calibration methods were researched and employed for the Hadamard transform imaging spectrometer. A point light source in long distance was used for the pixel response nonuniformity correction of the CMOS detector. The uncertainty of the relative calibration was 4.6%. Solar simulator and spectral radiometer were used in absolute radiation calibration of the whole system, and the uncertainty of the absolute radiation calibration was 8.92%. Both of the uncertainty of relative calibration and the uncertainty of the absolute radiation calibration met the requirements of the projection. By actual objects imaging, the laboratory calibration methods of the Hadamard transform imaging spectrometer are proved accurate.

  19. Information systems in radiation protection: the INIS database; Sistemas de informacion en proteccion radiologica: la base de datos INIS

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi Larranaga, I.; Marco Arboli, M.

    2011-07-01

    INIS provides a comprehensive service references on literature information on radiation protection (RP), nuclear science and technology, medicine, etc.., Processing most of the world's scientific and technical literature in the area to meet the information needs international community in the areas of interest of the IAEA and the activities related to peaceful use of nuclear science and technology.

  20. Conception of the Instrument Calibration Laboratory of Ionizing Radiation Measurement (LACIMRI) of CTMSP - Sao Paulo, SP; Concepcao do Laboratorio de Calibracao de Instrumentos de Medicao de Radiacao Ionizante (LACIMRI) do CTMSP, Sao Paulo, SP

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Raimundo Dias da; Kibrit, Eduardo, E-mail: raimundo@ctmsp.mar.mil.b, E-mail: kibrit@ctmsp.mar.mil.b [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), Sao Paulo, SP (Brazil)

    2009-07-01

    The present work describes the phases of implantation of calibration laboratory of ionizing radiation measurement instruments at the CTMSP, Sao Paulo, in a priory approved by CNEN, Brazil. That laboratory will allow and enhance the present metrological capacity for the attendance to the growing demand for calibration services of the instruments

  1. The ENEA calibration service for ionising radiations. Part 1: Photons; Il centro di taratura per la radiazioni ionizzanti di Bologna. Parte 1: Fotoni

    Energy Technology Data Exchange (ETDEWEB)

    Monteventi, F.; Sermenghi, I. [ENEA Centro Ricerche Ezio Clementel, Bologna (Italy). Dipt. Ambiente

    1999-07-01

    The ENEA (National Agency for New Technology, Energy and the Environment) calibration service for ionizing radiations has been active for 40 years in the secondary standard dosimetry laboratory web. It has been the first center, in 1985, to be acknowledges by the Italian calibration service (SIT) for the two quantities for photons: exposure and air kerma. Since the Institute for the Radiation Protection of ENEA has moved to the new site in Montecuccolino (Bologna, Italy) in 1995, the whole laboratory has been renovated and all irradiation rooms together with radiation source and equipment have been reorganized according to the {chi}, {gamma}, {beta} and neutron fields metrology requirements. The aim of this report, as the first part of a report describing all facilities available at the service, is to give a detailed description of all equipment s qualified for photon fields metrology including the secondary standards and the calibration procedures performed for radiation monitoring devices and dosemeters. [Italian] Il centro di taratura dell'ENEA di Bologna opera nel campo della metrologia secpndaria da quasi 40 anni ed e' stato il primo centro nel 1985 ad essere riconosciuto dal SIT (Servizio di Taratura in Italia) per le grandezze esposizione e Kerma in aria. Con l'insediamento di tutto l'Istituto per la Radioprotezione nella nuova sede di Montecuccolino sono state ricostruite e riorganizzate anche tutte le sale di irraggiamento e tutti gli impianti radiogeni a disposizione per la metrologia delle radiazioni X, gamma, beta e neutroni. Intenzione di questo primo rapporto e' descrivere le attrezzature qualificate per la metrologia fotonica, dei campioni di misura e delle procedure adottate per la taratura degli strumenti e dei dosimetri.

  2. Medicina array demonstrator: calibration and radiation pattern characterization using a UAV-mounted radio-frequency source

    Science.gov (United States)

    Pupillo, G.; Naldi, G.; Bianchi, G.; Mattana, A.; Monari, J.; Perini, F.; Poloni, M.; Schiaffino, M.; Bolli, P.; Lingua, A.; Aicardi, I.; Bendea, H.; Maschio, P.; Piras, M.; Virone, G.; Paonessa, F.; Farooqui, Z.; Tibaldi, A.; Addamo, G.; Peverini, O. A.; Tascone, R.; Wijnholds, S. J.

    2015-06-01

    One of the most challenging aspects of the new-generation Low-Frequency Aperture Array (LFAA) radio telescopes is instrument calibration. The operational LOw-Frequency ARray (LOFAR) instrument and the future LFAA element of the Square Kilometre Array (SKA) require advanced calibration techniques to reach the expected outstanding performance. In this framework, a small array, called Medicina Array Demonstrator (MAD), has been designed and installed in Italy to provide a test bench for antenna characterization and calibration techniques based on a flying artificial test source. A radio-frequency tone is transmitted through a dipole antenna mounted on a micro Unmanned Aerial Vehicle (UAV) (hexacopter) and received by each element of the array. A modern digital FPGA-based back-end is responsible for both data-acquisition and data-reduction. A simple amplitude and phase equalization algorithm is exploited for array calibration owing to the high stability and accuracy of the developed artificial test source. Both the measured embedded element patterns and calibrated array patterns are found to be in good agreement with the simulated data. The successful measurement campaign has demonstrated that a UAV-mounted test source provides a means to accurately validate and calibrate the full-polarized response of an antenna/array in operating conditions, including consequently effects like mutual coupling between the array elements and contribution of the environment to the antenna patterns. A similar system can therefore find a future application in the SKA-LFAA context.

  3. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  4. Optimization of radiation protection in gamma radiography facilities; Otimizacao do sistema de radioprotecao nas instalacoes radiograficas de gamagrafia

    Energy Technology Data Exchange (ETDEWEB)

    Antonio Filho, Joao

    1999-07-01

    To determine optimized dose limits for workers, a study of optimization of radiation protection was undertaken in gamma radiography facilities closed, using the Technique Multiple Attributes Utility Analysis. A total of 217 protection options, distributed in 34 irradiation scenarios for tree facility types ( fixed open, moveable and closed (bunker) were analyzed. In the determination of the optimized limit dose, the following attributes were considered; costs of the protection barriers, costs attributed to the biological detriment for different alpha (the reference value of unit collective dose), size of the isolation area, constrained limits dose of annual individual equivalent doses and collective dose. The variables studied in the evaluation included: effective work load, type and activity of the sources of radiation ({sup 192}Ir and {sup 60}Co), source-operator distance related to the characteristic of the length of the command cable and the guide tube, type and thickness of the materials used in the protection barriers (concrete, barite, ceramic, lead, steel alloy and tungsten). The optimal analytic solutions obtained in the optimization process that resulted in the indication of the optimized dose limit were determined by means of a sensitivity analysis and by direct and logic evaluations, thus, independent of the values of the monetary coefficient attributed to the biological detriment, of the annual interest rate applied to the protection cost and of the type of installation studied, it was concluded that the primary limit of annual equivalent dose for workers (now 50 mSv) can be easily reduced to an optimized annual dose limit of 5 mSv. (author)

  5. Use of Transportable Radiation Detection Instruments to Assess Internal Contamination from Intakes of Radionuclides Part II: Calibration Factors and ICAT Computer Program.

    Science.gov (United States)

    Anigstein, Robert; Olsher, Richard H; Loomis, Donald A; Ansari, Armin

    2016-12-01

    The detonation of a radiological dispersion device or other radiological incidents could result in widespread releases of radioactive materials and intakes of radionuclides by affected individuals. Transportable radiation monitoring instruments could be used to measure radiation from gamma-emitting radionuclides in the body for triaging individuals and assigning priorities to their bioassay samples for in vitro assessments. The present study derived sets of calibration factors for four instruments: the Ludlum Model 44-2 gamma scintillator, a survey meter containing a 2.54 × 2.54-cm NaI(Tl) crystal; the Captus 3000 thyroid uptake probe, which contains a 5.08 × 5.08-cm NaI(Tl) crystal; the Transportable Portal Monitor Model TPM-903B, which contains two 3.81 × 7.62 × 182.9-cm polyvinyltoluene plastic scintillators; and a generic instrument, such as an ionization chamber, that measures exposure rates. The calibration factors enable these instruments to be used for assessing inhaled or ingested intakes of any of four radionuclides: Co, I, Cs, and Ir. The derivations used biokinetic models embodied in the DCAL computer software system developed by the Oak Ridge National Laboratory and Monte Carlo simulations using the MCNPX radiation transport code. The three physical instruments were represented by MCNP models that were developed previously. The affected individuals comprised children of five ages who were represented by the revised Oak Ridge National Laboratory pediatric phantoms, and adult men and adult women represented by the Adult Reference Computational Phantoms described in Publication 110 of the International Commission on Radiological Protection. These calibration factors can be used to calculate intakes; the intakes can be converted to committed doses by the use of tabulated dose coefficients. These calibration factors also constitute input data to the ICAT computer program, an interactive Microsoft Windows-based software package that estimates intakes of

  6. Traceable Pyrgeometer Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Mike; Kutchenreiter, Mark; Reda, Ibrahim; Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Newman, Martina; Webb, Craig

    2016-05-02

    This presentation provides a high-level overview of the progress on the Broadband Outdoor Radiometer Calibrations for all shortwave and longwave radiometers that are deployed by the Atmospheric Radiation Measurement program.

  7. Sistemas audiovisuales

    OpenAIRE

    Tarrés Ruiz, Francisco

    2000-01-01

    Conté: 1. Televisión analógica y digital El libro presenta una descripción detallada de los diferentes sistemas de televisión analógica y digital e incluye un análisis exhaustivo de numerosos aspectos tecnológicos e históricos, siempre desde una perspectiva sistemática y generalista dirigida tanto a estudiantes universitarios como a técnicos de grado superior. Tras una introducción a los sistemas de comunicación visual, en la que se analizan las distintas etapas de la conversión de una...

  8. THE METHOD OF DETERMINATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 3. The dependence of the radiation beam characteristics

    Directory of Open Access Journals (Sweden)

    E. V. Titovich

    2016-01-01

    Full Text Available To ensure the radiation protection of oncology patients is needed to provide the constancy of functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. For this purpose, their quality control procedures are realized including calibration of radiation output of the linac, so the error in determining the dose reference value during this procedure must not exceed 2 %. The aim is to develop a methodology for determining the error in determining this value, depending on the characteristics of the radiation beam. Dosimetric measurements of Trilogy S/N 3567 linac dose distributions have been carried out for achievement of the objectives, on the basis of which dose errors depending on the dose rate value, the accuracy of the beam quality and output factors determination, the symmetry and uniformity of the radiation field, the angular dependence of the linac radiation output were obtained. It was found that the greatest impact on the value of the error has the error in the output factors determination (up to 5.26 % for both photon energy. Dose errors caused by changing dose rate during treatment were different for two photon energies, and reached 1.6 % for 6 MeV and 1.4 % for 18 MeV. Dose errors caused by inaccuracies of the beam quality determination were different for two photon energies, and reached 1.1 % for 18 MeV and –0.3 % for 6 MeV. Errors caused by the remaining of the characteristic do not exceed 1 %. Thus, there is a possibility to express the results of periodic quality control of the linear accelerator in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output.

  9. Establishing cytogenetic biodosimetry laboratory in Saudi Arabia and producing preliminary calibration curve of dicentric chromosomes as biomarker for medical dose estimation in response to radiation emergencies.

    Science.gov (United States)

    Al-Hadyan, Khaled; Elewisy, Sara; Moftah, Belal; Shoukri, Mohamed; Alzahrany, Awad; Alsbeih, Ghazi

    2014-12-01

    In cases of public or occupational radiation overexposure and eventual radiological accidents, it is important to provide dose assessment, medical triage, diagnoses and treatment to victims. Cytogenetic bio-dosimetry based on scoring of dicentric chromosomal aberrations assay (DCA) is the "gold standard" biotechnology technique for estimating medically relevant radiation doses. Under the auspices of the National Science, Technology and Innovation Plan in Saudi Arabia, we have set up a biodosimetry laboratory and produced a national standard dose-response calibration curve for DCA, pre-required to estimate the doses received. For this, the basic cytogenetic DCA technique needed to be established. Peripheral blood lymphocytes were collected from four healthy volunteers and irradiated with radiation doses between 0 and 5 Gy of 320 keV X-rays. Then, lymphocytes were PHA stimulated, Colcemid division arrested and stained cytogenetic slides were prepared. The Metafer4 system (MetaSystem) was used for automatic and manually assisted metaphase finding and scoring of dicentric chromosomes. Results were fit to the linear-quadratic dose-effect model according to the IAEA EPR-Biodosimetry-2011 report. The resulting manually assisted dose-response calibration curve (Y = 0.0017 + 0.026 × D + 0.081 × D(2)) was in the range of those described in other populations. Although the automated scoring over-and-under estimates DCA at low (2 Gy) doses, respectively, it showed potential for use in triage mode to segregate between victims with potential risk to develop acute radiotoxicity syndromes. In conclusion, we have successfully established the first biodosimetry laboratory in the region and have produced a preliminary national dose-response calibration curve. The laboratory can now contribute to the national preparedness plan in response to eventual radiation emergencies in addition to providing information for decision makers and public health officials who assess the

  10. Sistema Solar

    OpenAIRE

    Federación de Asociaciones de Astronomía Cielo de Comellas

    2004-01-01

    Lección sobre el Sistema Solar. Curso de Astronomía Básica, segunda edición, impartido por los miembros de la Federación de Asociaciones de Astronomía Cielo de Comellas. Casa de la Ciencia, sábados, del 24 de septiembre al 22 de octubre de 2011

  11. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  12. Calibration of {sup 90}Sr+{sup 90}Y chemical applicators using a mini extrapolation chamber as reference system;Calibracao de aplicadores clinicos de {sup 90}Sr+{sup 90}Y utilizando uma mini-camera de extrapolacao como sistema de referencia

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Oliveira, Mercia L. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2009-07-01

    {sup 90}Sr + {sup 90}Y clinical applicators are beta radiation sources utilized in several radiotherapy Brazilian clinics, although don't be more manufactured. These sources are employed in brachytherapy procedures for the treatment of superficial lesions of skin and eyes. International recommendations and previous works determine that dermatological and ophthalmic applicators shall be calibrated periodically, and one of the methods for their calibration consists of the use of an extrapolation chamber. In this work, a method of calibration of {sup 90}Sr + {sup 90}Y clinical applicators was applied using a mini-extrapolation chamber of plane window, developed at the Calibration Laboratory at IPEN, as a reference system. The results obtained were considered satisfactory, when compared with the results given in the calibration certificates of the sources. (author)

  13. Comparison of air kerma area product and air kerma meter calibrations for X-ray radiation qualities used in diagnostic radiology

    Science.gov (United States)

    Hourdakis, C. J.; Csete, I.; Daures, J.; Jarvinen, H.; Mihailescu, L.-C.; Sochor, V.; Novak, L.; Pedersen, M.; Kosunen, A.; Toroi, P.; Denoziere, M.; Büermann, L.; Megzifene, A.; Einarsson, G.; Ferrari, P.; dePooter, J.; Bjerke, H.; Brodecki, M.; Cardoso, J.; Bercea, S.; Ciraj-Bjelac, O.; Compel, J.; Glavič-Cindro, D.; Ginjaume, M.; Persson, L.; Grindborg, J.-E.

    2015-01-01

    The EURAMET #1177 project, identified as EURAMET RI(I) - S9 comparison, was the first EURAMET wide scale supplementary comparison in the field of diagnostic radiology for air kerma area product, PKA, and air kerma, K. It was conducted with the goal of testing the measurement and calibration capabilities for PKA and K, as well as of supporting the relevant CMCs of the participating laboratories. Two commercial KAP meters and an ionization chamber were selected as transfer instruments and circulated between the 22 European participants. The measurements were performed from April 2011 until July 2012. The stability and the performance of the transfer instruments were tested by the pilot laboratory (IRCL/GAEC-EIM) and few other laboratories as well. The test results revealed that the energy (radiation quality), Q, irradiation area, A, and air kerma rate, dot K dependences of response of the transfer KAP meters influence the comparison of the results when different measurement conditions were pertained and therefore, appropriate correction factors were obtained and applied to the reported calibration results of the laboratories, when necessary. The comparison reference values (CRVs) for each instrument were determined as the weighted mean of the calibration coefficients of the three participating primary laboratories. The relative standard uncertainty of the CRVs were in the range of (0.4 - 1.6)% depending on the transfer instruments and beam qualities. The comparison result as the ratio of the corrected calibration coefficient of participant and the respective CRV, and its uncertainty were calculated for all beam qualities and transfer instruments. The informative degrees of equivalence (DoE) were calculated for the refrence RQR 5 beam quality. In case of air kema area product measurements the results for the RADCAL PDC KAP meter were used. The 216 KAP meter calibration results of the two different transfer instruments in terms of air kerma area product were consistent

  14. Principles for the design and calibration of radiation protection dosemeters for operational and protection quantities for eye lens dosimetry.

    Science.gov (United States)

    Bordy, J M; Gualdrini, G; Daures, J; Mariotti, F

    2011-03-01

    The work package two of the ORAMED project--Collaborative Project (2008-2011) supported by the European Commission within its seventh Framework Programme--is devoted to the study of the eye lens dosimetry. A first approach is to implement the use of H(p)(3) by providing new sets of conversion coefficients and well suited calibration and type test procedures. This approach is presented in other papers in the proceedings of this conference. Taking into account that the eye lens is an organ close to the surface of the body, another approach would be to directly estimate the absorbed dose to the eye lens, D(lens,est) through a special calibration procedure although this quantity is not directly measurable. This paper is a methodological paper that tries to identify the critical aspects of a dosimetry in terms of D(lens).

  15. Laboratory for Calibration of Gamma Radiation Measurement Instruments (LabCal) of Institute of Chemical, Biological, Radiological and Nuclear Defense (IDQBRN) from Brazilian Army Technology Center (CTEx); Laboratorio de Calibracao de Instrumentode Medicao de Radiacao Gama (LabCal) do IDQBRN do CTEx

    Energy Technology Data Exchange (ETDEWEB)

    Amorim, Aneuri de; Balthar, Mario Cesar V.; Santos, Avelino; Vilela, Paulo Ricardo T. de; Oliveira, Luciano Santa Rita; Penha, Paulo Eduardo C. de Oliveira; Gonzaga, Roberto Neves; Andrade, Edson Ramos de; Oliveira, Celio Jorge Vasques de; Fagundes, Luiz Cesar S., E-mail: aneurideamorim@gmail.com [Centro Tecnologico do Exercito (DQBRN/CTEx), Rio de Janeiro, RJ (Brazil). Instituto de Defesa Quimica, Biologica, Radiologica e Nuclear

    2016-07-01

    This paper describes the calibration laboratory deployment steps (LABCAL) gamma ionizing radiation measuring instruments in the Army Technology Center, CTEx. Initially the calibration of radiation monitors will be held in the dosimetric quantity air kerma and operational quantity ambient dose equivalent H*(d). The LABCAL / CTEx has not yet authorized by CASEC / CNEN. This laboratory aims to calibrate the ionizing radiation instruments used by the Brazilian Army. (author)

  16. Evaluation of the calibration uncertainty of gamma radiation monitors using a {sup 137}Cs source; Avaliacao da incerteza de calibracao de monitores de radiacao gama com uma fonte de {sup 137}Cs

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Elisabeth; Leite, Sandro Passos; David, Mariano Gazineu; Estrada, Carlos Frederico Alves; Almeida, Carlos Eduardo de, E-mail: beth.fernandes56@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ/LCR), Rio de Janeiro (Brazil). Lab. de Ciencias Radiologicas

    2014-07-01

    This study shows all the relevant components to the calculation of the calibration uncertainty of gamma radiation area monitors performed by the Lab. Ciencias Radiologicas of UERJ . The uncertainty components will be related with their respective estimated values, details about the uncertainty components calculations of positioning and field homogeneity will be shown. There were obtained the values of 3,8 % and 5,8 % to the expanded uncertainty (k=2) for the dosimetry and for the area monitors calibration, respectively. (author)

  17. Exercise for laboratory comparison of calibration coefficient in {sup 137}Cs beam, radiation protection - 2013/2014; Exercicio de comparacao laboratorial do coeficiente de calibracao em feixe de Cesio-137, radioprotecao - 2013/2014

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, T.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Potiens, M.P.A., E-mail: tschirn@ird.gov.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Soares, C.M.A. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Silveira, R.R. [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Khoury, H. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Fernandes, E. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Ciencias Radiologicas; Cardoso, W.F. [Eletrobras Termonuclear S.A. (Eletronuclear), Rio de Janeiro, RJ (Brazil); Borges, J.C. [MRA Comercio de Instrumentos Eletronicos Ltda., Ribeirao Preto, SP (Brazil)

    2015-07-01

    This work deals with the preliminary results of the second exercise of comparing the radiation monitors calibration laboratories in Brazil. The exercise involved eight laboratories and the measured quantity is the air kerma in a beam of {sup 137}Cs for radioprotection. The exercise was conducted by the LNMRI/IRD, in a star shaped arrangement from October 2013 to July 2015. The largest deviation was 2% of the calibration coefficient that is acceptable for applications in radioprotection. (author)

  18. Studying the Important Relationship Between Earth's Plasma Sheet and the Outer Radiation Belt Electrons Using Newly Calibrated and Corrected Themis-Sst Data

    Science.gov (United States)

    Cruce, P. R.; Turner, D. L.; Angelopoulos, V.; Larson, D. E.; Shprits, Y.; Huang, C.; Ukhorskiy, A. Y.

    2011-12-01

    Most recently, the solid-state telescope (SST) data from the THEMIS mission, which consisted of 5 spacecraft in highly elliptic, equatorial orbits that have traversed the outer radiation belt and sampled the plasma sheet for more than 4 years, have been characterized, calibrated, and decontaminated. Here, we present a brief introduction on this corrected dataset and go into detail on the valuable resource it provides to address science questions concerning the important relationship between ~1 keV-10's keV electrons in the plasma sheet and 100's keV-MeV electrons in Earth's outer radiation belt. We demonstrate this by presenting preliminary results on: studying phase space density (PSD) radial gradients for fixed first and second adiabatic invariants from the radiation belt into the plasma sheet, examining pitch angle distributions near the boundary between these two regions, and studying the boundary region itself around the last closed drift shell and the role of magnetopause shadowing losses. We examine the dependence of PSD radial gradients on the first and second invariants to test previous results [e.g., Turner et al., GRL, 2008; Kim et al., JGR, 2010] that reveal mostly positive radial gradients for lower energy electrons (10's - couple hundred keV) but negative gradients for relativistic electrons beyond geosynchronous orbit. This directly relates to the current theory that lower energy electrons have a source in the plasma sheet and are introduced to the ring current and radiation belt via substorm injections and enhanced convection, and these particles then generate the waves necessary to accelerate a fraction of this seed population to relativistic energies, providing a source of the outer radiation belt. Next, we take advantage of the pitch angle resolved differential energy fluxes to examine variations in pitch angle distributions to establish the role that Shabansky drift orbits, which break electrons' second adiabatic invariant, play on outer belt

  19. SeaWiFS Postlaunch Technical Report Series. Volume 5; The SeaWiFS Solar Radiation-Based Calibration and the Transfer-to-Orbit Experiment

    Science.gov (United States)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Barnes, Robert A.; Eplee, Robert E., Jr.; Biggar, Stuart F.; Thome, Kurtis J.; Zalewski, Edward F.; Slater, Philip N.; Holmes, Alan W.

    1999-01-01

    The solar radiation-based calibration (SRBC) of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was performed on 1 November 1993. Measurements were made outdoors in the courtyard of the instrument manufacturer. SeaWiFS viewed the solar irradiance reflected from the sensor's diffuser in the same manner as viewed on orbit. The calibration included measurements using a solar radiometer designed to determine the transmittances of principal atmospheric constituents. The primary uncertainties in the outdoor measurements are the transmission of the atmosphere and the reflectance of the diffuser. Their combined uncertainty is about 5 or 6%. The SRBC also requires knowledge of the extraterrestrial solar spectrum. Four solar models are used. When averaged over the responses of the SeaWiFS bands, the irradiance models agree at the 3.6% level, with the greatest difference for SeaWiFS band 8. The calibration coefficients from the SRBC are lower than those from the laboratory calibration of the instrument in 1997. For a representative solar model, the ratios of the SRBC coefficients to laboratory values average 0.962 with a standard deviation of 0.012. The greatest relative difference is 0.946 for band 8. These values are within the estimated uncertainties of the calibration measurements. For the transfer-to-orbit experiment, the measurements in the manufacturer's courtyard are used to predict the digital counts from the instrument on its first day on orbit (August 1, 1997). This experiment requires an estimate of the relative change in the diffuser response for the period between the launch of the instrument and its first solar measurements on orbit (September 9, 1997). In relative terms, the counts from the instrument on its first day on orbit averaged 1.3% higher than predicted, with a standard deviation of 1.2% and a greatest difference of 2.4% or band 7. The estimated uncertainty for the transfer-to-orbit experiment is about 3 or 4%.

  20. Experimental evaluation of self-calibrating cavity radiometers for use in earth flux radiation balance measurements from satellites

    Science.gov (United States)

    Hickey, J. R.; Karoli, A. R.; Alton, B. M.

    1982-01-01

    A method for evaluating out-of-field response of wide-field, earth-viewing satellite radiometers is described. The equipment which simulates the earth and space consists of a central blackbody surrounded by a cooled ring. The radiometric and orbital considerations are discussed. Some test results for prototype ERBE cavity sensors are included. This presentation is restricted to longwave radiative transfer

  1. Spectral responsivity calibration of the reference radiation thermometer at KRISS by using a super-continuum laser-based high-accuracy monochromatic source

    Science.gov (United States)

    Yoo, Yong Shim; Kim, Gun Jung; Park, Seongchong; Lee, Dong-Hoon; Kim, Bong-Hak

    2016-12-01

    We report on the calibration of the relative spectral responsivity of the reference radiation thermometer, model LP4, which is used for the experimental realisation of the international temperature scale of 1990 above 960 °C at the Korea Research Institute of Standards and Science. The relative spectral responsivity of LP4 is measured by using a monochromatic source consisting of a super-continuum laser and a double-grating monochromator. By monitoring the wavelength of the output beam directly with a calibrated wavelength-meter, we achieved a high-accuracy measurement of spectral responsivity with a maximum wavelength error of less than 3 pm, a narrow spectral bandwidth of less than 0.4 nm, and a high dynamic range over 8 decades. We evaluated the contributions of various uncertainty components of the spectral responsivity measurement to the uncertainty of the temperature scale based on a practical estimation approach, which numerically calculates the maximal effects of the variations of each component. As a result, we evaluate the uncertainty contribution from the spectral responsivity measurement to the temperature scale to be less than 64 mK (k  =  1) in a range from 660 °C to 2749 °C for the LP4 with a filter at 650 nm.

  2. 基于光谱响应定标的辐射测温方法%Radiation Thermometry Based on Calibration of Spectral Responsivity

    Institute of Scientific and Technical Information of China (English)

    辛成运; 程晓舫; 张忠政

    2012-01-01

    True surface temperatures can be determined by measurements of radiation emitted by the object. The non-spectral parameter in the radiation measurement equation is the function of the relative position between the target and the lens, so calibration of space position is necessary for temperature measurement, when emissivity and temperature are measured simultaneously. In the present paper, the non-spectral parameter was included into the undetermined coefficients of emissivity modeled by finite series, which will not affect the solution of true surface temperature. Therefore, radiation thermometry can be accomplished without calibration of space position and normalization of measurement data. And not the true spectral emissivity but the trend of it can be measured. Two special examples were investigated, respectively. The results indicate that when the effective wavelength of each channel is different, multi-wavelength radiation thermometry equations have the unique solution, while the number of the multiband ones may be zero, one, two or even three%辐射测温是通过测量物体发出的辐射来反演温度,辐射测量方程中含有与空间位置相关的非光谱参数,通常需通过辐射标定予以确认.而该研究将非光谱参数归入有限项级数形式的光谱发射率中,这既不会影响多通道测温方程组的封闭性,又不会影响真温求解,从而在无需测量数据归一化的条件下,实现了无需空间位置标定的辐射测温,该方法仅需要标定仪器的绝对光谱响应或相对光谱响应,但不能解得发射率.以两个特例分别对多波长测温方法和多谱段测温方法的求解特性进行了研究.结果表明:对于任意的测量矢量,有效波长不相同的多波长测温唯一解是存在的;而多谱段测温时,存在无解区域,双解直线,甚至可能存在三解直线.

  3. Calibration of the High Resolution Gamma Spectrometry Detection Systems from the Environmental Radioactivity Unit and Radiological Surveillance (ARU and RV); Calibracion de los Sistemas Detectores de Espectrometria Gamma de Alta Resolucion de la Unidad de Radiactividad Ambiental y Vigilancia Radiologica (URA y VR)

    Energy Technology Data Exchange (ETDEWEB)

    Suarez-Navarro, J. A.; Gasco, C.; Arana, M.; Suanez, A.

    2012-11-01

    In accordance with international regulations and with the quality criteria imposed by the internal quality system of the laboratory of gamma spectrometry, which belongs to the Unit of Environmental Radioactivity and Radiation Monitoring (URA y VR), it is necessary to perform a periodic calibration of the measurement systems of gamma spectrometry. The equipment calibration carries with the need for the preparation of the geometries of measurement and calibration in energy and in efficiencies. This report reflects the procedures for the preparation of the wide range of geometries available in the laboratory, as well as the different calibrations performed with those geometries in almost all the laboratory gamma detectors using the CANBERRA software Genie 2k. (Author) 9 refs.

  4. 定向X射线检测系统检验辐射场的调校方法%Adjustment and Calibration Method of Inspection Radiation Field for Directional X-ray Inspection System

    Institute of Scientific and Technical Information of China (English)

    刘通; 边昭斌; 张圣光; 蒋太秋

    2015-01-01

    介绍了螺旋缝埋弧焊管检测用定向X射线检测系统检验辐射场的构成,以及实际检验中需要调整DR检测系统的机构,如探臂、射线管头、平板探测器等的调整。重点介绍了定向X射线检测系统检验辐射场的两种调校方法,即螺栓校准和辐射场校准器校准,分析了两种调校方法的优缺点。以自主设计的辐射场校准器调校方法为例,通过对φ325 mm×8 mm焊管进行辐射场差异模拟试验,得到了不正确调校辐射场对焊偏检验结果有一定影响的结论。%In this article, it briefly introduced the structure of inspection radiation field for directional X-ray inspection system used in SAWH pipe, and some organizations need to adjust DR inspection system, such as exploring arm, tube head, flat panel detector etc. It emphasized 2 adjustment and calibration methods for directional X-ray inspection system, the bolt calibration and radiation field calibrator, and analyzed advantages and disadvantages for the above two methods. Taking independent design radiation field calibrator calibration method as sample, through radiation field difference simulation test for φ325 mm ×8 mm welded pipe, it is concluded that incorrect calibration radiation field has certain influence on misalignment inspection result.

  5. Cross-calibration of the Transition Radiation Detector of AMS-02 for an Energy Measurement of Cosmic-Ray Ions

    CERN Document Server

    Obermeier, Andreas

    2014-01-01

    Since May 2011 the AMS-02 experiment is installed on the International Space Station and is observing cosmic radiation. It consists of several state-of-the-art sub-detectors, which redundantly measure charge and energy of traversing particles. Due to the long exposure time of AMS-02 of many years the measurement of momentum for protons and ions is limited systematically by the spatial resolution and magnetic field strength of the silicon tracker. The maximum detectable rigidity for protons is about 1.8~TV, for helium about 3.6~TV. We investigate the possibility to extend the range of the energy measurement for heavy nuclei ($Z\\geq2$) with the transition radiation detector (TRD). The response function of the TRD shows a steep increase in signal from the level of ionization at a Lorentz factor $\\gamma$ of about 500 to $\\gamma\\approx20000$, where the transition radiation signal saturates. For heavy ions the signal fluctuations in the TRD are sufficiently small to allow an energy measurement with the TRD beyond t...

  6. Study of the alignment of X radiation beam for calibration of chambers used in radiotherapy; Estudo do alinhamento do feixe de raios-X para calibracao de camaras utilizadas em radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Ricardo de Souza; Bossio, Francisco; Peixoto, Jose Guilherme Pereira, E-mail: ricardo@ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    The activities developed in radiotherapy, diagnostic radiology and radiation safety, require that the metrological parameters involving these activities have on its results a high degree of reliability, to ensure traceability. To meet the existing demand in Brazil, the National Metrology Laboratory of Ionizing Radiation - LNMRI - is deploying a new tube X-ray beams used in the calibration of the standard rooms, which serve to quality control in hospitals, clinics and industry. (author)

  7. Study of the behavior of radiation detectors for mammography in standard beams using a clinical system; Estudo do comportamento de detectores de radiacao para mamografia em feixes padroes utilizando um sistema clinico

    Energy Technology Data Exchange (ETDEWEB)

    Barreira, Jacqueline Sales

    2014-07-01

    A mammogram is the x-ray of the breast that allows early detection of cancer, by being able to show lesions in very small early stage. But to get an early and reliable diagnosis is necessary that the mammography unit is calibrated and working properly, otherwise there may be a loss in image produced, may lead to a false diagnosis, and possible harm to the patient. So it is important to control these devices, especially in relation to the radiation produced by them. In this project, we propose a study of the behavior of ionization chambers for mammography calibrated beam patterns in a clinical system (Philips-VMI mammography, Graph Mammo AF, which operates a range of 20 to 35 kV) from Instruments Calibration Laboratory at IPEN-CNEN/SP, with the aim of determining parameters correction approaching conditions calibration conditions for clinical use. Measurements of the parameters of the beams set in mammography using simulators acrylic specially developed for these measurements were performed in order to establish a new protocol for calibration of the ionization chambers in a clinical system rather than the industrial system, or as a complement to this. (author)

  8. Energy and directional response for the Harshaw dosemeter holders 8814 and 8891, and its effect on the appropriate radiation qualities for absolute calibration.

    Science.gov (United States)

    Børretzen, I; Wøhni, T

    2003-01-01

    The personal dosimetry laboratory at the Norwegian radiation protection authority utilises a two-element dosemeter card for measuring Hp(10) and Hp(0.07), in a Harshaw dosemeter holder type 8814. Energy and directional responses for photons and betas for this holder have been assessed, as well as for the new Harshaw holder type 8891. The energy response characteristics for the 12-1250 keV photon energy range, in terms of TL output per unit Hp(10) and Hp(0.07) have been evaluated. The maximum over-response to under-response ratio for the Hp(10) element was found to be 1.46 for the new type 8891 holder, as compared to 1.55 for the older type 8814. The new holder also displays a more favourable directional response for this element. For the Hp(0.07) element, no significant differences with regard to energy or directional responses were found. Selecting radiation energy for absolute calibration of the Hp(10) and Hp(0.07) elements are discussed.

  9. Energy and directional response for the Harshaw dosemeter holders 8814 and 8891, and its effect on the appropriate radiation qualities for absolute calibration

    Energy Technology Data Exchange (ETDEWEB)

    Borretzen, I.; Wohni, T

    2003-07-01

    The personal dosimetry laboratory at the Norwegian radiation protection authority utilises a two-element dosemeter card for measuring H{sub p}(10) and H{sub p}(0.07), in a Harshaw dosemeter holder type 8814. Energy and directional responses for photons and betas for this holder have been assessed, as well as for the new Harshaw holder type 8891. The energy response characteristics for the 12-1250 keV photon energy range, in terms of TL output per unit H{sub p}(10) and H{sub p}(0.07) have been evaluated. The maximum over-response to under-response ratio for the H{sub p}(10) element was found to be 1.46 for the new type 8891 holder, as compared to 1.55 for the older type 8814. The new holder also displays a more favourable directional response for this element. For the H{sub p}(0.07) element, no significant differences with regard to energy or directional responses were found. Selecting radiation energy for absolute calibration of the H{sub p}(10) and H{sub p}(0.07) elements are discussed. (author)

  10. Design of solar simulator in the meteorological radiation calibration system%气象辐射标定系统中太阳模拟器的设计

    Institute of Scientific and Technical Information of China (English)

    刘石; 张国玉; 孙高飞; 苏拾; 王凌云; 高玉军

    2013-01-01

      为了解决对太阳辐射测量仪器的检测问题,提出一种高精度的气象辐射标定系统。重点阐述了系统中太阳模拟器聚光系统、光学积分器的优化技术;详细论述了影响太阳模拟器均匀度的积分器像差以及积分器投影镜组的离焦效果,并提出最佳离焦量的经验公式,设计了准直光学系统,并用LightTools软件对系统进行仿真;最后,对系统中的太阳模拟器进行测试。测试数据表明:该太阳模拟器可模拟一个太阳常数,辐照面范围为200 mm,辐照不均匀度在60 mm 范围内小于依1%,在(60-200)mm范围内小于2%,不稳定度优于依1%/h,满足气象辐射标定系统的要求。%  In order to solve the problem that how to measure solar radiation measure instrument, a kind of high precision meteorological radiation calibration system was put forward. The optimization technique of focusing system and optical integrator was described; integrator aberration which influenced the uniformity of sun simulator in detail and defocusing effect of projector lens were discussed. The optimal defocus distance formula was put forward at the same time. The collimating optical system and simulated the system in LightTools were designed. Finally, solar simulator was tested. The results show that it can simulate one solar constant with irradiation range of 200 mm, working distance of 1 000 mm. Irradiation nonuniformity in 60 mm range is less than 1%, and in( 60- 200)mm is less than 2%, instability is better than 1%/h, which meets the requirements of meteorological radiation calibration system.

  11. Calibration of the Ångström-Prescott coefficients (a, b) under different time scales and their impacts in estimating global solar radiation in the Yellow River basin

    DEFF Research Database (Denmark)

    Liu, Xiaoyling; Mei, Xurong; Li, Yuzhong

    2009-01-01

    The Ångström-Prescott (A-P) equation relating in its current form the incident top-of-atmosphere solar radiation to the solar radiation received at the surface, is one of the most accurate and widely used sunshine-based methods estimating global solar radiation (Rs). The key in its application is...... higher a and lower b and larger variations over those using daily data. At yearly time scale, the sunshine-radiation relationship can no longer be described by the linear A-P formula. The difference in coefficients between daily and monthly calibration was rather large accounting for 71...... location. However, the large effect of time scales on a and b produced no significant impact on the estimation accuracy of Rs because of the conservative response of the sum a + b to time scale. In this sense, the coefficients calibrated at daily scale are interchangeable with those calibrated at monthly...... scale, indicating the high flexibility of the A-P formula. Nevertheless, calibration made at daily scale has two important advantages over monthly scale in that it requires fewer years' data to obtain stabilized coefficients, and that it is easily predicted more accurately with common site information...

  12. The environmental radiation monitoring system in Spain El sistema de vigilancia radiológica ambiental en España

    Directory of Open Access Journals (Sweden)

    Carmen Rey del Castillo

    2010-12-01

    Full Text Available The system of environmental radiation monitoring established in Spain is composed of several networks with different objectives, a monitoring network in the vicinity of the facilities and several national networks financed and managed by public agencies. The operators of the facilities are responsible for the conduct of its Environmental Radiological Surveillance Program as directed by the CSN. Moreover, the Directorate General of Civil Defense and Emergencies has a Radioactivity Warning Network (RAR consisting of over 900 automatic stations measuring dose rate distributed nationwide. The Environmental Radioactivity Monitoring Network (Revira, managed by the CSN, is a nationwide network, consists of a Network of Sampling Stations (REM and a Network of Automatic Stations for continuous monitoring (REA. The autonomous communities of Valencia, Catalonia, Extremadura and the Basque Country have their own automated networks similar to that of the CSN. Revira provides information on the radioactivity in the air, soil, water (drinking, inland and sea and of food. The sampling and analysis programs are tailored to radiological recommendations laid down in the European Union Commission. The REM has the collaboration of laboratories in universities and the Centre for Energy, Environmental and Technological Research (CIEMAT for execution. The monitoring of inland and coastal waters is undertaken by the Centre for Studies and Experimentation of Public Works, Ministry of Public Works (CEDEX.El sistema de vigilancia radiológica del medio ambiente establecido en España está constituido por varias redes con diferentes objetivos: una red de vigilancia en el entorno de las instalaciones y varias redes de ámbito nacional financiadas y gestionadas por organismos públicos. Los titulares de las instalaciones son los responsables de la realización de sus programas de vigilancia radiológica ambiental siguiendo las directrices del Consejo de Seguridad Nuclear

  13. Calibration of the γ-H2AX DNA double strand break focus assay for internal radiation exposure of blood lymphocytes.

    Science.gov (United States)

    Eberlein, Uta; Peper, Michel; Fernández, Maria; Lassmann, Michael; Scherthan, Harry

    2015-01-01

    DNA double strand break (DSB) formation induced by ionizing radiation exposure is indicated by the DSB biomarkers γ-H2AX and 53BP1. Knowledge about DSB foci formation in-vitro after internal irradiation of whole blood samples with radionuclides in solution will help us to gain detailed insights about dose-response relationships in patients after molecular radiotherapy (MRT). Therefore, we studied the induction of radiation-induced co-localizing γ-H2AX and 53BP1 foci as surrogate markers for DSBs in-vitro, and correlated the obtained foci per cell values with the in-vitro absorbed doses to the blood for the two most frequently used radionuclides in MRT (I-131 and Lu-177). This approach led to an in-vitro calibration curve. Overall, 55 blood samples of three healthy volunteers were analyzed. For each experiment several vials containing a mixture of whole blood and radioactive solutions with different concentrations of isotonic NaCl-diluted radionuclides with known activities were prepared. Leukocytes were recovered by density centrifugation after incubation and constant blending for 1 h at 37°C. After ethanol fixation they were subjected to two-color immunofluorescence staining and the average frequencies of the co-localizing γ-H2AX and 53BP1 foci/nucleus were determined using a fluorescence microscope equipped with a red/green double band pass filter. The exact activity was determined in parallel in each blood sample by calibrated germanium detector measurements. The absorbed dose rates to the blood per nuclear disintegrations occurring in 1 ml of blood were calculated for both isotopes by a Monte Carlo simulation. The measured blood doses in our samples ranged from 6 to 95 mGy. A linear relationship was found between the number of DSB-marking foci/nucleus and the absorbed dose to the blood for both radionuclides studied. There were only minor nuclide-specific intra- and inter-subject deviations.

  14. Calibration of the γ-H2AX DNA double strand break focus assay for internal radiation exposure of blood lymphocytes.

    Directory of Open Access Journals (Sweden)

    Uta Eberlein

    Full Text Available DNA double strand break (DSB formation induced by ionizing radiation exposure is indicated by the DSB biomarkers γ-H2AX and 53BP1. Knowledge about DSB foci formation in-vitro after internal irradiation of whole blood samples with radionuclides in solution will help us to gain detailed insights about dose-response relationships in patients after molecular radiotherapy (MRT. Therefore, we studied the induction of radiation-induced co-localizing γ-H2AX and 53BP1 foci as surrogate markers for DSBs in-vitro, and correlated the obtained foci per cell values with the in-vitro absorbed doses to the blood for the two most frequently used radionuclides in MRT (I-131 and Lu-177. This approach led to an in-vitro calibration curve. Overall, 55 blood samples of three healthy volunteers were analyzed. For each experiment several vials containing a mixture of whole blood and radioactive solutions with different concentrations of isotonic NaCl-diluted radionuclides with known activities were prepared. Leukocytes were recovered by density centrifugation after incubation and constant blending for 1 h at 37°C. After ethanol fixation they were subjected to two-color immunofluorescence staining and the average frequencies of the co-localizing γ-H2AX and 53BP1 foci/nucleus were determined using a fluorescence microscope equipped with a red/green double band pass filter. The exact activity was determined in parallel in each blood sample by calibrated germanium detector measurements. The absorbed dose rates to the blood per nuclear disintegrations occurring in 1 ml of blood were calculated for both isotopes by a Monte Carlo simulation. The measured blood doses in our samples ranged from 6 to 95 mGy. A linear relationship was found between the number of DSB-marking foci/nucleus and the absorbed dose to the blood for both radionuclides studied. There were only minor nuclide-specific intra- and inter-subject deviations.

  15. X-Ray Ccds for Space Applications: Calibration, Radiation Hardness, and Use for Measuring the Spectrum of the Cosmic X-Ray Background

    Science.gov (United States)

    Gendreau, Keith Charles

    1995-01-01

    This thesis has two distinct components. One concerns the physics of the high energy resolution X-ray charge coupled devices (CCD) detectors used to measure the cosmic X-ray background (XRB) spectrum. The other involves the measurements and analysis of the XRB spectrum and instrumental background with these detectors on board the advanced satellite for cosmology and astrophysics (ASCA). The XRB has a soft component and a hard component divided at ~2 keV. The hard component is extremely isotropic, suggesting a cosmological origin. The soft component is extremely anisotropic. A galactic component most likely dominates the soft band with X-ray line emission due to a hot plasma surrounding the solar system. ASCA is one of the first of a class of missions designed to overlap the hard and soft X-ray bands. The X-ray CCD's energy resolution allows us to spectrally separate the galactic and cosmological components. Also, the resolution offers the ability to test several specific cosmological models which would make up the XRB. I have concentrated on models for the XRB origin which include active galactic nuclei (AGN) as principal components. I use ASCA data to put spectral constraints on the AGN synthesis model for the XRB. The instrumental portion of this thesis concerns the development and calibration of the X-ray CCDs. I designed, built and operated an X-ray calibration facility for these detectors. It makes use of a reflection grating spectrometer to measure absolute detection efficiency, characteristic absorption edge strengths, and spectral redistribution in the CCD response function. Part of my thesis research includes a study of radiation damage mechanisms in CCDs. This work revealed radiation damage-induced degradation in the spectral response to X-rays. It also uncovered systematic effects which affect both data analysis and CCD design. I have developed a model involving trap energy levels in the CCD band gap structure. These traps reduce the efficiency in which

  16. Radiation dosimetry

    CERN Document Server

    Hine, Gerald J; Hine, Gerald J

    1956-01-01

    Radiation Dosimetry focuses on the advancements, processes, technologies, techniques, and principles involved in radiation dosimetry, including counters and calibration and standardization techniques. The selection first offers information on radiation units and the theory of ionization dosimetry and interaction of radiation with matter. Topics include quantities derivable from roentgens, determination of dose in roentgens, ionization dosimetry of high-energy photons and corpuscular radiations, and heavy charged particles. The text then examines the biological and medical effects of radiation,

  17. Calibration uncertainty

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Anglov, Thomas

    2002-01-01

    Methods recommended by the International Standardization Organisation and Eurachem are not satisfactory for the correct estimation of calibration uncertainty. A novel approach is introduced and tested on actual calibration data for the determination of Pb by ICP-AES. The improved calibration unce...

  18. Calibration of the ALICE transition radiation detector and a study of Z{sup 0} and heavy quark production in pp colissions at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Bailhache, Raphaelle

    2009-01-28

    The ALICE Experiment is one of the four experiments installed at the Large Hadron Collider (LHC). One of its detector-systems, the Transition Radiation Detector (TRD), is a gas detector designed for electron identification and charged particle tracking. The charged particle ionizes the gas along its path and electrons drift in an uniform field of 700 V/cm over 3 cm before being amplified. We implemented procedures to calibrate the drift velocity of the electrons, the time-offset of the signal, the amplification factor and the width of the Pad Response Function (PDF) characterizing the sharing of the deposited charge over adjacent pads. Physics events (pp and PbPb collisions) will be used. The performances of the algorithms were tested on simulated pp collisions at {radical}(s)=14 TeV and on first real data taken with cosmic-rays in the ALICE setup. The calibration software was installed on the Data Acquisition System at CERN and executed continuously during the cosmic-ray data taking in 2008, providing a first determination of the calibration constants. This thesis presents also a study on the capability of the ALICE central barrel to detect the Z{sup 0} boson through the decay Z{sup 0}{yields}e{sup +}e{sup -} in pp collisions at 14 TeV. We demonstrated that the Z{sup 0}{yields}e{sup +}e{sup -} is characterized by a very clean signal in the dielectron reconstructed invariant mass spectrum. At such high transverse momentum (about 45 GeV/c), the electrons from Z{sup 0} are identified with the Transition Radiation Detector. The remaining background from misidentified pions and electrons from heavy-flavored decays are rejected by the requirement of two isolated reconstructed tracks. The main challenge comes from the very small production rate. Therefore we estimated the efficiency of a trigger based on a low p{sub T} cut and electron identification with the TRD and showed that about 100 Z{sup 0}{yields}e{sup +}e{sup -} can be reconstructed per year employing such a

  19. Preliminary results in the development of system for remote mapping of radiation; Resultados preliminares no desenvolvimento de sistema para mapeamento remoto de radiacao

    Energy Technology Data Exchange (ETDEWEB)

    Jesus, Miller F. de; Carvalho, Paulo Victor R. de; Farias, Marcos S., E-mail: mil-far@hotmail.com, E-mail: paulov@ien.gov.br, E-mail: msantana@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Engenharia Nuclear

    2013-07-01

    This paper presents a project that aims to use virtual instrumentation on mobile devices to carry out radiation monitoring in an environment using mobile robots. The idea is to use this development to reduce the need for exposed workers at nuclear facilities. The design is based on a mobile robot that is controlled by commands sent via network wireless. The robot is coupled to the body a radiation monitor that is designed to send the radiation in the environment data rate also through the wireless network. The system is completed by programs developed for controlling the robot and receiving the radiation rate measurements, enabling remote and mobile monitoring of radiation and automating the mapping of radiation in the environment.

  20. Quality control beam of radiation through imaging system using a flat panel (ILD); Control de calidad de haz de radiacion mediante un sistema de imagen de panel plano (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Benitez Serrano, J. A.; Gomez Barrado, A.; Sanchez-Reyes, A.

    2013-07-01

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  1. Use of the electronic system of portal image for quality control and calibration of the position of blades of multi leaf collimation system of an accelerator Elekta synergy; Uso del sistema electronico de imagen portal para el control de calidad y la calibracion de la posicion de las laminas del sistema de colimacion multilaminas de un acelerador elekta synergy

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Merino, G.; Cortes Rodicio, J.; Lope Lope, R.; Martin gonzalez, T.; Garcia Fidalgo, M. A.

    2013-07-01

    We present our methodology for quality control of the positioning of the blades using electronic portal imaging system (ILD). Also an example of its usefulness for calibration multi leaf collimation system (MLC). (Author)

  2. Parameters of calibration of the measurement system of {sup 222} Rn based in LR-115; Parametros de calibracion del sistema de medicion de {sup 222} Rn basado en LR-115

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, M.L.; Mireles, F.; Quirino, L.; Davila, I.; Lugo, F.; Pinedo, J.L. [CREN-UAZ, 98068 Zacatecas (Mexico); Chavez, A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: mluisagb@hotmail.com

    2003-07-01

    Since the SSNTD technique (Solid State Nuclear Track Detection) it was discovered it has been used as passive method for the detection of subnuclear particles in great variety of fields of the science. The use of the technique in measurements of {sup 222} Rn in air have already been established implying better methodologies in the exhibition to the environment until their engraving and reading processes. The SSNTD technique is since a method by comparison since the material it can be used a single time, therefore it requires of calibration in one controlled radon atmosphere, using gauged standards. The objective of this work is to show the calibration of the devices used as radon monitors based on SSNTD. The material used as SSNTD is LR-115 Il. The standardization of the parameters used in the exhibition to radon in air, engraving and reading process, its are based on the response of the LR-115 Il, the one arrangement of the device, engraving speed and mainly the calibration factor. They are considered two types of monitors: Open camera and Closed camera, the difference among the calibration factors of both cameras is the percentage of the descendants of radon in the open camera. The standardized parameters are operation voltage of the counting system; temperature, time and concentration of the engraving solution; and thickness. (Author)

  3. Laboratory Calibration of X-ray Velocimeters for Radiation Driven Winds and Outflows Surrounding X-ray Binaries and Active Galactic Nuclei

    Science.gov (United States)

    Brown, Gregory V.; Beiersdorfer, P.; Graf, A.; Hell, N.; Liedahl, D.; Magee, E. W.; Träbert, E.; Beilmann, C.; Bernitt, S.; Crespo-Lopez-Urritiua, J.; Eberle, S.; Kubicek, K.; Mäckel, V.; Rudolph, J.; Steinbrügge, R.; Ullrich, J.; Kelley, R. L.; Kilbourne, C. A.; Leutenegger, M.; Porter, F. S.; Rasmussen, A.; Simon, M.; Epp, S.

    2011-09-01

    High resolution measurements of X-ray absorption and fluorescence by radiation driven winds and outflows surrounding X-ray binaries and AGN provide a powerful means for measuring wind velocities. The accuracy of these X-ray velocimeters is limited by the accuracy of atomic data. For example, in the case of the high mass X-ray binary Vela X-1 the uncertainty in the calculated transition wavelengths of the K alpha lines produced by photoionization and photoexcitation of Si L-shell ions is comparable to the likely Doppler shifts, making it impossible to determine a reliable velocity. Similar problems also exist in the case of absorption of X-rays by M-shell Fe ions, which produces in some AGN the so-called unresolved transition array across the 15-17 angstrom band. In this case, there is a 15-45 milliangstrom variation among different wavelength calculations. The uncertainty in the calculations makes it impossible to reliably determine the true velocity structure of the outflow, and in turn, prevents a reliable determination of the mass-loss rate of the AGN. We present results of a recent series of laboratory experiments conducted using an electron beam ion trap coupled with the LCLS X-ray free electron laser and the BESSY-II synchrotron and designed to calibrate the velocimeters provided by high resolution instruments on Chandra and XMM-Newton. We also present results of resonant photoexcitation measurements of the transition wavelength of an Fe XVI satellite line 'coincident' with the 2p-3d Fe XVII line 3D at 15.26 angstroms. This line has never been resolved using emission spectroscopy and its measurement confirms the intensity of line 3D is sensitive to the relative abundance of Fe XVI and XVII and thus temperature. Work at LLNL was performed under the auspices of DOE under contract DE-AC53-07NA27344 and supported by NASA's APRA program.

  4. Calibração multivariada para sistemas com bandas sobrepostas através da análise da fatores do tipo Q Q mode factor multivariate calibration for systems with overlapped bands

    Directory of Open Access Journals (Sweden)

    Ieda Spacino Scarminio

    1998-10-01

    Full Text Available A multivariate calibration method to determine chemical compositions of systems with severely overlapped bands is proposed. Q mode factors are determined from the spectral data and subsequently rotated using the varimax and oblique transformation of Imbrie. The method is applied to two sets of simulated data to test the sensitivity of analytical results to random experimental error. The chemical concentrations of alanine and threonine mixture are determined from spectral data of the 302,5 - 548,5 nm region.

  5. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  6. Study of radiation portal monitor and its application to metal recycling industry; Estudio de un sistema de deteccion tipo portico para su aplicacion en la industria del metal

    Energy Technology Data Exchange (ETDEWEB)

    Pujol, L.; Lara-Calleja, S.; Suarez-Navarro, M. J.; Gonzalez-Gonzalez, J. A.

    2009-07-01

    The industry of the iron and the steel in one of the most important sectors in Spain for its economic development. the recycling of metallic materials as well as the import of metallic scrap is very significant. Several reports on accidental dispersion or smelting of radioactive sources in metal recycling industries confirm the possibility that radioactive material might be mixed with scrap. In consequence, this type of accident shows the necessity of a rigorous and specific radiation control of the sector. The control of these materials with radioactive content can be carried out with radiation portal monitors installed at the entrance of these industries. The detection of radioactive materials presents special features as the continuous background acquisition or the minimisation of the relatively large number of innocent/nuisance detections. In the present work, we study a radiation portal monitor, the FHT-1388-T Thermo-Eberline. This is one of the usual radiation portal systems installed at the entrance of the metal recycling industry. Se study the characteristics and parameters of this portal monitor to optimise its use. furthermore, we propose some rapid tests for radiation portal systems in metal recycling industry. (Author) 16 refs.

  7. Comparative study among calibration methods of clinical applicators of beta radiation; Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, Patricia de Lara

    2009-07-01

    {sup 90}Sr+{sup 90}Y clinical applicators are instruments used in brachytherapy procedures and they have to be periodically calibrated, according to international standards and recommendations. In this work, four calibration methods of dermatological and ophthalmic applicators were studied, comparing the results with those given by the calibration certificates of the manufacturers. The methods included the use of the standard applicator of the Calibration Laboratory (LCI), calibrated by the National Institute of Standards and Technology; an Amersham applicator (LCI) as reference; a mini-extrapolation chamber developed at LCI as an absolute standard; and thermoluminescent dosimetry. The mini-extrapolation chamber and a PTW commercial extrapolation chamber were studied in relation to their performance through quality control tests of their response, as leakage current, repeatability and reproducibility. The distribution of the depth dose in water, that presents high importance in dosimetry of clinical applicators, was determined using the mini extrapolation chamber and the thermoluminescent dosimeters. The results obtained were considered satisfactory for the both cases, and comparable to the data of the IAEA (2002) standard. Furthermore, a dosimetry postal kit was developed for the calibration of clinical applicators using the thermoluminescent technique, to be sent to clinics and hospitals, without the need of the transport of the sources to IPEN for calibration. (author)

  8. The radiation isocenter verification using an electronic system of image portal; Verificacion del isocentro de radiacion utilizando un sistema electronico de imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Merino Gestoso, J. A.; Portas Ferradas, B. C.; Rosa Menendez, P.; Chapel Gomez, M. L.; Fernandez Cerezo, S.; Vazquez Varela, P.

    2013-07-01

    In this paper we present a procedure optimized for verification the isocenter of radiation with respect to the rotation of the gantry and the turn isocentric table of two accelerators SIEMENS, ONCOR and ARTISTE with a mannequin developed in our service and analyzing the images acquired with the EPID from each of the teams. (Author)

  9. Los Sistemas Peatonales Como Sistemas De Transporte

    Directory of Open Access Journals (Sweden)

    Lindsay Álvarez Pomar

    2015-01-01

    Full Text Available Los sistemas peatonales han cobrado importancia dentro de los sistemas de movilidad debido al aumento de los viajes peatonales. Este aumento se ha debido a la concientización de las personas sobre las ventajas de caminar, al aumento del uso de los sistemas de transporte público y en algunos casos a los escasos recursos económicos. En la última década, los sistemas peatonales han sido incluidos en la planeación de movilidad de algunas ciudades. Sin embargo, su definición formal carece del despliegue de sus componentes, así como del análisis de las interrelaciones entre los mismos. Se presenta una propuesta que puede servir de base para su definición formal, con el fin de ser usada para su análisis y diseño. Se concluye que las definiciones actuales no cubren todos los aspectos clave de los sistemas peatonales, para que puedan ser un buen soporte para la toma de decisiones sobre este tipo de sistemas y se distinguenlos componentes estructurales que se consideran importantes.

  10. Mexican national pyronometer network calibration

    Science.gov (United States)

    VAldes, M.; Villarreal, L.; Estevez, H.; Riveros, D.

    2013-12-01

    In order to take advantage of the solar radiation as an alternate energy source it is necessary to evaluate the spatial and temporal availability. The Mexican National Meterological Service (SMN) has a network with 136 meteorological stations, each coupled with a pyronometer for measuring the global solar radiation. Some of these stations had not been calibrated in several years. The Mexican Department of Energy (SENER) in order to count on a reliable evaluation of the solar resource funded this project to calibrate the SMN pyrometer network and validate the data. The calibration of the 136 pyronometers by the intercomparison method recommended by the World Meterological Organization (WMO) requires lengthy observations and specific environmental conditions such as clear skies and a stable atmosphere, circumstances that determine the site and season of the calibration. The Solar Radiation Section of the Instituto de Geofísica of the Universidad Nacional Autónoma de México is a Regional Center of the WMO and is certified to carry out the calibration procedures and emit certificates. We are responsible for the recalibration of the pyronometer network of the SMN. A continuous emission solar simulator with exposed areas with 30cm diameters was acquired to reduce the calibration time and not depend on atmospheric conditions. We present the results of the calibration of 10 thermopile pyronometers and one photovoltaic cell by the intercomparison method with more than 10000 observations each and those obtained with the solar simulator.

  11. Development and calibration of system for measuring of {sup 220} Rn in exhaled air; Desenvolvimento e calibracao de um sistema para medidas de {sup 220} RN no ar exalado

    Energy Technology Data Exchange (ETDEWEB)

    Lucena, Eder Augusto de; Lipisztein, Joyce L. [Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, RJ (Brazil)

    1999-11-01

    Th{sup 233} is the parent of one of the natural radioactive series. This series contains {sup 220} Rn which is a noble gas. The study of this radionuclide is very important to estimate the intake via inhalation, due to the suspension of {sup 220} Rn decay products in situations where occupational exposure may occur. These situations include mining, milling and the use of minerals containing {sup 232} Th. This work contains a detailed description of the development of a device to measure thoron and its decay products in the human breath. This document also contains information about the calibration procedures using a {sup 228} Th standard liquid source. The detection system consists of a Zn S(Ag)-mylar disc coupled to a photomultiplier tube, which allows direct measurement of the activity in exhaled air. The calibration factor, determined through the measurements of the {sup 228} Th standard liquid source during 1 h and 30 minutes, was found to be (61 +/-3) Bq/cpm.(author) 3 refs., 3 figs.

  12. Training system in radiation protection of workers of a radioactive facility; Sistema de capacitacion en seguridad radiologica de los trabajadores en una instalacion radiactiva

    Energy Technology Data Exchange (ETDEWEB)

    Amador Balbona, Zayda; Perez Pijuan, Saul; Ayra Pardo, Fernando E.; Soria Guevara, Miguel A., E-mail: zabalbona@centis.edu.cu [Centro de Isotopos (CENTIS), Mayabeque (Cuba)

    2013-07-01

    The following topics are addressed: the state of the art of the studies on the biological effects of ionizing radiation, the new national regulations, operational experiences and in the transportation of radioactive materials and those obtained from the radiological events, radioactive waste management and the analysis of culture of safety in the installation. It evaluates the effectiveness of the training system through the analysis of the occurrence of radiological incidents and behavior of occupational exposure.

  13. Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams; Projeto, construcao e caracterizacao de camaras de ionizacao para utilizacao como sistemas padroes em feixes de radiacao X e gama

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula

    2013-07-01

    Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this PhD program. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system. (author)

  14. Radiation protection of patients in diagnostic radiology: implementation of a management system optimization; Proteccion radiologica de pacientes en radiodiagnostico: implantacion de un sistema de gestion de la optimizacion

    Energy Technology Data Exchange (ETDEWEB)

    Corpas Rivera, L.; Devesa Pardo, F. J.; Gamez Jimenez, J. L.; Vallejo Carrascal, C.; Garcia de Diego, A. A.; Amador Vela-Hidalgo, J. J.

    2011-07-01

    The enforcement of quality in diagnostic radiology (Royal Decree 1976/1999 laying down the criteria for quality in diagnostic radiology and Royal Decree 815/2001 to justify the use of ionizing radiations for medical exposure, etc.) and recommendations and European regulations on the matter, is done by carrying out the optimization of the doses received, based on image quality in a continuous process of monitoring of such dose from the dose reference Values ??(VRD ) that the system has allowed to establish for each technique.

  15. Automation of the radiation protection monitoring system in the RP-10 reactor; Automatizacion del sistema de monitoraje de radioproteccion en el reactor RP-10

    Energy Technology Data Exchange (ETDEWEB)

    Anaya G, Olgger; Castillo Y, Walter; Ovalle S, Edgar [Instituto Peruano de Energia Nuclear, Lima (Peru)

    2002-07-01

    During the reactor operation, it is necessary to carry out the radiological control in the different places of the reactor, in periodic form and to take a registration of these values. For it the radioprotection official, makes every certain periods, settled down in the procedures, to verify and to carry out the registration of those values in manual form of each one of the radiation monitors. For this reason it was carried out the design and implementation of an automatic monitoring system of radioprotection in the reactor. In the development it has been considered the installation of a acquisition data system for 27 radiation gamma monitors of the type Geiger Mueller, installed inside the different places of the reactor and in the laboratories where they are manipulated radioactive material, using as hardware the FieldPoint for the possessing and digitalization of the signs which are correspondents using the communication protocol RS-232 to a PC in which has settled a program in graphic environment that has been developed using the tools of the programming software LabWindows/CVI. Then, these same signs are sent 'on line' to another PC that is in the Emergency Center of Coordination to 500 m of the reactor, by means of a system of radiofrequency communication. (author)

  16. Case study on the effect of cosmic radiation in embedded systems in aircraft; Estudo de caso sobre o efeito da radiacao cosmica em sistemas embarcados em aeronaves

    Energy Technology Data Exchange (ETDEWEB)

    Prado, Adriane C.M.; Pereira, Marlon A., E-mail: adriane.acm@hotmail.com, E-mail: marlon@ieav.cta.br [Instituto Tecnologico de Aeronautica (ITA/DCTA), Sao Jose dos Campos, SP (Brazil); Federico, Claudio A.; Goncalez, Odair L., E-mail: claudiofederico@ieav.cta.br, E-mail: odairl@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil)

    2014-07-01

    High-energy neutrons generated from the interaction of cosmic radiation with atoms of the atmosphere, can cause adverse effects on avionics devices. These effects are referred to as 'Single Event Effects' (SEE) and may occur especially in aircraft onboard computers, from change the logic state of memory cells or functional interruptions, which could compromise flight safety. The effects of the SEE must first be evaluated and entered into the safety analysis process in order to determine the susceptibility to failures by SEE devices. SEE rate can be evaluated separately for thermal neutrons and fast neutrons with energy above 10 MeV. This paper presents an exploratory study of susceptibility to radiation to a specific type of SRAM memory, during periods of maximum and minimum solar, in situations of equatorial and polar flight in the typical flight altitude of existing aircraft and, at higher altitudes, near the maximum of Pfotzer. This study was conducted using estimates of particle flows employing the EXPACS QARM codes and evaluating the expected rate of SEE due to thermal neutrons and fast neutrons separately. The distribution in energy and the flow of neutrons inside the airplane are influenced by the total mass of the aircraft and this influence are also discussed.

  17. The Advanced LIGO Photon Calibrators

    CERN Document Server

    Karki, S; Kandhasamy, S; Abbott, B P; Abbott, T D; Anders, E H; Berliner, J; Betzwieser, J; Daveloza, H P; Cahillane, C; Canete, L; Conley, C; Gleason, J R; Goetz, E; Kissel, J S; Izumi, K; Mendell, G; Quetschke, V; Rodruck, M; Sachdev, S; Sadecki, T; Schwinberg, P B; Sottile, A; Wade, M; Weinstein, A J; West, M; Savage, R L

    2016-01-01

    The two interferometers of the Laser Interferometry Gravitaional-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events, and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as Photon Calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO Photon Calibrators that are currently providing fiducial displacements on the order of $10^{-18}$ m/$\\sqrt{\\textrm{Hz}}$ with accuracy and precision of better ...

  18. The Advanced LIGO photon calibrators

    Science.gov (United States)

    Karki, S.; Tuyenbayev, D.; Kandhasamy, S.; Abbott, B. P.; Abbott, T. D.; Anders, E. H.; Berliner, J.; Betzwieser, J.; Cahillane, C.; Canete, L.; Conley, C.; Daveloza, H. P.; De Lillo, N.; Gleason, J. R.; Goetz, E.; Izumi, K.; Kissel, J. S.; Mendell, G.; Quetschke, V.; Rodruck, M.; Sachdev, S.; Sadecki, T.; Schwinberg, P. B.; Sottile, A.; Wade, M.; Weinstein, A. J.; West, M.; Savage, R. L.

    2016-11-01

    The two interferometers of the Laser Interferometry Gravitational-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as photon calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO photon calibrators that are currently providing fiducial displacements on the order of 1 0-18m /√{Hz } with accuracy and precision of better than 1%.

  19. Sistemas roboticos teleoperados

    Directory of Open Access Journals (Sweden)

    Alexander Ceron Correa

    2005-01-01

    Full Text Available En el presente artículo se realiza una revisión general sobre los sistemas robóticos teleoperados, su estructura, componentes principales, clasificación, tipos de sensores, sistemas de locomoción y aplicaciones; como ejemplo se mencionan algunos trabajos realizados Colombia y en el mundo

  20. Sistemas roboticos teleoperados

    OpenAIRE

    Alexander Ceron Correa

    2005-01-01

    En el presente artículo se realiza una revisión general sobre los sistemas robóticos teleoperados, su estructura, componentes principales, clasificación, tipos de sensores, sistemas de locomoción y aplicaciones; como ejemplo se mencionan algunos trabajos realizados Colombia y en el mundo

  1. Sposobnost opstanka informacionih sistema

    OpenAIRE

    Bosko Rodic; Dejan Vuletic

    2005-01-01

    U radu je opisan znacaj i trend razvoja informacionih sistema u savremenom drustvu, a definisani su i drugi znacajni pojmovi radi boljeg razumevanja problema. Prikazana su i cetiri aspekta resenja sposobnosti opstanka informacionih sistema koje predlaze Computer Emergency Response Team (CERT).

  2. Calibration of a Gamma Spectrometry System Used for the Determination of Cs-137 in Spanish Soils; Puesta a Punto de un sistema de Expectrometria Gamma para la Determinacion de Cs-137 en Suelos Espanoles

    Energy Technology Data Exchange (ETDEWEB)

    Barreraa, M.; Romero, M. L.; Valino, F.

    2008-07-01

    The document describes the methodology used at CIEMAT in order to determine, by gamma spectrometry, the background levels of the radionuclide Cs-137 in soils of the Spanish peninsular territory. the work is a part of an extensive research project developed jointly by the University of the Basque Country (UPV-EHU) and the CIEMAT, endellite Content and migration of radiocaesium and radiostrontium in Spanish soils, which is funded by the Plan I+D of the Spanish Nuclear Security Council (CSN). The objective of the project is to establish the reference levels of man-made radionuclides in Spanish soils, with respect to which the evaluation of a possible posterior accidental release of radioactive material could be appraised. The activity concentration of the fission products Cs-137 has been determined in 34 soil cores extracted from representative Spanish soils type zones. This publication describes the experimental system employed, its calibration, the particular conditions applied to perform the measurements, as well as the experimental validation of the methodology. The activity profiles and inventories of the radioactive element so obtained are also presented. The estimation of the background Cs-137 reference levels, will provide a basis for later applications as the study of the spatial distribution in the region, the determination of the correlation between the deposited activity and the meteorological conditions, or the calculation of the specific migration parameters of the radioactive elements in Mediterranean conditions. (Author) 15 refs.

  3. The SOS system like model to study the response to the ionizing radiation; El sistema SOS como modelo para estudiar la respuesta a la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Serment G, J.; Brena V, M., E-mail: jorge.serment@inin.gob.m [ININ, Departamento de Radiobiologia, Laboratorio de Genetica Microbiana, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-07-01

    One of the important aspects in the radiobiology is the study of the strategies that the alive beings follow to counteract the genetic lesions generated by ionizing radiation. Among these is the SOS response of the bacteria, a group of 60 genes approximately that is activated when they happen lesions in the DNA and whose causes and structural diversity are multiple. So, an interest point in this response is to elucidate as all this lesions diversity activates this response in turn since, the protein that begins the process only recognizes simple ruptures of the double helix. For this is comes off that in the great majority of the cases is required of a previous prosecution of the damages so that the structure is generated that shoots this system. In this work a brief summary of the contributions in this field is made by part of the Microbiology Laboratory of the Instituto Nacional de Investigaciones Nucleares (ININ). (Author)

  4. Utilization of ultraviolet radiation in effluent disinfestation of domestic waste treatment systems; Utilizacao da radiacao ultravioleta na desinfeccao de efluentes de sistemas de tratamento de esgotos domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, P.R.R. [Companhia de Tecnologia de Saneamento Ambiental, Sao Paulo, SP (Brazil); Andrade e Silva, L.G. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1995-12-31

    Ultraviolet radiation disinfection of Upflow Anaerobic Sludge Biodigestor (UASB) and UASB with aerated lagoon pos-treatment effluents is possible to be reached utilizing a single low pressure mercury lamp arc (15 W nominal power) in a shell tube flow through reactor (1.2 L useful volume). Fecal coliforms, total coliforms and colifages were used as microbiological parameters. For fecal coliforms, about 3 logarithmic units (log. un.) was removed from UASB with aerated lagoon pos-treatment effluent and 4 log. un. from UASB effluent with 7 and 30 seconds of hydraulic retention time, respectively. Good empirical correlations were obtained between microbiological parameters and hydraulic retention times. (author). 4 refs, 1 fig, 3 tabs.

  5. The ferrous ammonium sulfate solid system, as dosemeter for processes at low temperatures and high doses of gamma radiation; El sistema sulfato ferroso amoniacal solido, como dosimetro para procesos a bajas temperaturas y altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Juarez C, J.M.; Ramos B, S.; Negron M, A. [ICN-UNAM, 04510 Mexico D.F. (Mexico)

    2005-07-01

    This paper presents the results obtained from a study of the radiation induced oxidation of crystalline ferrous ammonium sulfate with gamma rays at 295 K, 263 K and 77 K and dose from 0 to 300 kGy. The radiation induced decomposition of ferrous ammonium sulfate has been studied by the dissolution of the irradiated salt in 0,8 N sulfuric acid. The main product is Fe{sup 3+} and molar concentration of ferric ion was determined spectrophotometrically in the UV region at 304 nm. The optical density values showed a linear dependence with dose, indicating that the data obtained might be used to create a calibrating curve. Color in irradiated salt changes from blue to green, yellow and orange according to the absorbed dose. The accuracy and the reproducibility of the system were tested. In addition, some other characteristics make possible the use of this system as a dosimeter, similar to Fricke chemical dosemeter, at low temperatures and high dose. (Author)

  6. Commissioning of a Monte Carlo treatment planning system for clinical use in radiation therapy; Evaluacion de un sistema de planificacion Monte Carlo de uso clinico para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Zucca Aparcio, D.; Perez Moreno, J. M.; Fernandez Leton, P.; Garcia Ruiz-Zorrila, J.

    2016-10-01

    The commissioning procedures of a Monte Carlo treatment planning system (MC) for photon beams from a dedicated stereotactic body radiosurgery (SBRT) unit has been reported in this document. XVMC has been the MC Code available in the treatment planning system evaluated (BrainLAB iPlan RT Dose) which is based on Virtual Source Models that simulate the primary and scattered radiation, besides the electronic contamination, using gaussian components for whose modelling are required measurements of dose profiles, percentage depth dose and output factors, performed both in water and in air. The dosimetric accuracy of the particle transport simulation has been analyzed by validating the calculations in homogeneous and heterogeneous media versus measurements made under the same conditions as the dose calculation, and checking the stochastic behaviour of Monte Carlo calculations when using different statistical variances. Likewise, it has been verified how the planning system performs the conversion from dose to medium to dose to water, applying the stopping power ratio water to medium, in the presence of heterogeneities where this phenomenon is relevant, such as high density media (cortical bone). (Author)

  7. Radiation calibration and error analysis for a large-aperture infrared opto-electric system%大口径红外光电系统辐射定标及误差分析

    Institute of Scientific and Technical Information of China (English)

    杨词银; 曹立华

    2011-01-01

    为了实现对大口径红外光电系统的辐射定标,建立了基于大面源黑体的辐射定标系统以及基于红外单色照明光管的光谱定标系统.利用腔型黑体、连续可变滤光片CVF和平行光管组成红外单色照明光管,对红外系统进行光谱定标,确定系统归一化相对光谱响应函数.利用大面源黑体覆盖红外系统入瞳和视场,对红外系统进行辐射定标,确定系统绝对辐射亮度响应度α.对α的误差源进行了分析计算:α的不确定度主要来自于红外系统输出数码值、大面源黑体辐射、光谱定标和背景辐射的不确定度,经测量和计算分别为0.4%、4.9%、2.5%、1.9%.计算结果表明,响应度α的不确定度为6.1%,满足红外系统10%定标精度的要求.%To perform radation calibration on infrared opto-electric system with a large-aperture, a radiation calibration system based on extended area blackbody and a spectral calibration system based on infrared monochroic collimator were established. The infrared monochroic collimator was composed of a cavity blackbody, a circular variable filter (CVF) and a collimator. It was used to calibrate the infrared opto-electric system spectrally in order to determine its normalized relative spectral response function. A large extended area blackbody, which covered the input pupil and the view field of the infrared opto-electric system, was used to perform radiation calibration on the infrared system in order to determine its absolute radiance responsivity. Analysis on error sources of the radiance responsivity was performed, and the uncertainty of the responsivity came from uncertainties for the output value of the infrared opto-electric system, radiation emitting from the extended area blackbody, the spectral calibration and the background radiation, which were 0.4% 、4.9% ,2.5% 、 1.9% respectively after measuring and calculating. The calculation results show that the uncertainty of the

  8. HIRDLS monochromator calibration equipment

    Science.gov (United States)

    Hepplewhite, Christopher L.; Barnett, John J.; Djotni, Karim; Whitney, John G.; Bracken, Justain N.; Wolfenden, Roger; Row, Frederick; Palmer, Christopher W. P.; Watkins, Robert E. J.; Knight, Rodney J.; Gray, Peter F.; Hammond, Geoffory

    2003-11-01

    A specially designed and built monochromator was developed for the spectral calibration of the HIRDLS instrument. The High Resolution Dynamics Limb Sounder (HIRDLS) is a precision infra-red remote sensing instrument with very tight requirements on the knowledge of the response to received radiation. A high performance, vacuum compatible monochromator, was developed with a wavelength range from 4 to 20 microns to encompass that of the HIRDLS instrument. The monochromator is integrated into a collimating system which is shared with a set of tiny broad band sources used for independent spatial response measurements (reported elsewhere). This paper describes the design and implementation of the monochromator and the performance obtained during the period of calibration of the HIRDLS instrument at Oxford University in 2002.

  9. Il Sistema Costituzionale Italiano

    OpenAIRE

    2015-01-01

    Conferencia sobre el sistema constitucional italiano,centrándose en la forma de gobierno de Italia y sus principales instituciones. Tres fueron los perfiles en los que la ponente hizo hincapié: la relación entre el Gobierno y el Parlamento; las funciones desempeñadas por los partidos políticos en el sistema representativo italiano y las leyes electorales que a lo largo de la historia republicana del país han reglamentado el sistema electoral. I...

  10. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. Part 2. Dependence on the characteristics of collimator, optical sourse-distance indicator, treatment field, lasers and treatment couch

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2016-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide consistent functional characteristics of the medical linear accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linac, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error (difference between a measured value of quantity and its true value in determining this value, depending on the characteristics of the collimator, the source to surface distance pointer, lasers, radiation field and treatment table. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the collimator, the deviation of the collimator rotation isocenter, the sourcesurface distance pointer accuracy, field size accuracy, the accuracy of lasers and treatment table positioning were obtained. It was found that the greatest impact on the value of the error has the error in the optical SSD indication and the error in the lasers position in the plane perpendicular to the plane of incidence of the radiation beam (up to 3.64 % for the energy of 6 MV. Dose errors caused by error in the field size were different for two photon energies, and reached 2.54 % for 6 MeV and 1.33% for 18 MeV. Errors caused by the rest of the characteristic do not exceed 1 %. Thus, it is possible to express the results of periodic quality control of these devices integrated in linac in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation on the basis of the calibration of radiation output in case of development of techniques that allow to analyze the influence dosimetric

  11. Possible use of self-calibration to reduce systematic uncertainties in determining distance-redshift relation via gravitational radiation from merging binaries

    CERN Document Server

    Saini, Tarun Deep; Sahni, Varun

    2010-01-01

    By observing mergers of compact objects, future gravity wave experiments would measure the luminosity distance to a large number of sources to a high precision but not their redshifts. Given the directional sensitivity of an experiment, a fraction of such sources (gold plated -- GP) can be identified optically as single objects in the direction of the source. We show that if an approximate distance-redshift relation is known then it is possible to statistically resolve those sources that have multiple galaxies in the beam. We study the feasibility of using gold plated sources to iteratively resolve the unresolved sources, obtain the self-calibrated best possible distance-redshift relation and provide an analytical expression for the accuracy achievable. We derive lower limit on the total number of sources that is needed to achieve this accuracy through self-calibration. We show that this limit depends exponentially on the beam width and give estimates for various experimental parameters representative of futu...

  12. Sistema de arbitraje

    OpenAIRE

    2015-01-01

    Con el propósito de garantizar la calidad de las publicaciones de la Revista Científica Virtual  Horizonte Empresarial, en el presente volumen 2 N° 2, 2015, queda estipulado el siguiente sistema de arbitraje.

  13. ALTEA: The instrument calibration

    Energy Technology Data Exchange (ETDEWEB)

    Zaconte, V. [INFN and University of Rome Tor Vergata, Department of Physics, Via della Ricerca Scientifica 1, 00133 Rome (Italy)], E-mail: livio.narici@roma2.infn.it; Belli, F.; Bidoli, V.; Casolino, M.; Di Fino, L.; Narici, L.; Picozza, P.; Rinaldi, A. [INFN and University of Rome Tor Vergata, Department of Physics, Via della Ricerca Scientifica 1, 00133 Rome (Italy); Sannita, W.G. [DISM, University of Genova, Genova (Italy); Department of Psychiatry, SUNY, Stoony Brook, NY (United States); Finetti, N.; Nurzia, G.; Rantucci, E.; Scrimaglio, R.; Segreto, E. [Department of Physics, University and INFN, L' Aquila (Italy); Schardt, D. [GSI/Biophysik, Darmstadt (Germany)

    2008-05-15

    The ALTEA program is an international and multi-disciplinary project aimed at studying particle radiation in space environment and its effects on astronauts' brain functions, as the anomalous perception of light flashes first reported during Apollo missions. The ALTEA space facility includes a 6-silicon telescopes particle detector, and is onboard the International Space Station (ISS) since July 2006. In this paper, the detector calibration at the heavy-ion synchrotron SIS18 at GSI Darmstadt will be presented and compared to the Geant 3 Monte Carlo simulation. Finally, the results of a neural network analysis that was used for ion discrimination on fragmentation data will also be presented.

  14. Efeitos de baixas doses de radiação-X no desenvolvimento do sistema nervoso central: estudo experimental em ratos Effects of low X-radiation doses on the central nervous system development: an experimental study in rats

    Directory of Open Access Journals (Sweden)

    Liliane Lins

    2008-02-01

    Full Text Available OBJETIVO: Este trabalho analisa as conseqüências da irradiação-X no desenvolvimento do sistema nervoso de fetos de ratos. MATERIAIS E MÉTODOS: O trabalho foi constituído de 10 Rattus norvegicus albinos, Wistar, fêmeas, grávidas, com idade de oito semanas. Cinco ratas fêmeas constituíram o grupo controle e outras cinco tiveram suas regiões abdominais expostas por 30 segundos a uma dose de 0,3 Gy proveniente de um aparelho odontológico Gnatus de 70 kV e 10 mA. No 17º dia gestacional, ambos os grupos foram submetidos a histerectomia. As seções selecionadas foram examinadas para análise cerebral comparativa entre os grupos. RESULTADOS: O exame clínico revelou não haver diferenças morfológicas entre os grupos controle e experimental e nenhum dos animais apresentou anormalidades grosseiras. Vinte e sete por cento dos animais do grupo experimental apresentaram hemorragia cerebral moderada e 73% apresentaram hemorragia severa e danos no tecido nervoso. Nenhum animal do grupo controle apresentou hemorragia cerebral ou danificações de tecido nervoso. CONCLUSÃO: Estas evidências demonstram que pequenas doses de radiação-X podem causar hemorragias cerebrais e, conseqüentemente, lesão tecidual nervosa.OBJECTIVE: The present study analyzes the consequences of X-irradiation for the development of the nervous system of rat fetuses. MATERIALS AND METHODS: The sample included ten eight-week-old, pregnant Rattus norvegicus albinus, Wistar. Five female rats constituted the control group and other five had their abdominal region exposed for 30 seconds to a single 0.3 Gy radiation dose from a 70 kV, 10 mA Gnatus odontological apparatus. At the 17th gestational day both groups were submitted to hysterectomy. Selected sections were examined for comparative brain analysis of both groups. RESULTS: The clinical evaluation demonstrated no morphological difference between the control and the experimental groups. Twenty-seven percent of the

  15. ARM Shortwave and Longwave Radiometer Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Mike; Kutchenreiter, Mark; Reda, Ibrahim; Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Newman, Martina; Webb, Craig

    2017-03-23

    This presentation provides a high-level overview of shortwave and longwave calibrations performed at the U.S. Department of Energy's Atmospheric Radiation Measurement program Southern Great Plains site.

  16. An apparatus for the study of high temperature water radiolysis in a nuclear reactor: calibration of dose in a mixed neutron/gamma radiation field.

    Science.gov (United States)

    Edwards, Eric J; Wilson, Paul P H; Anderson, Mark H; Mezyk, Stephen P; Pimblott, Simon M; Bartels, David M

    2007-12-01

    The cooling water of nuclear reactors undergoes radiolytic decomposition induced by gamma, fast electron, and neutron radiation in the core. To model the process, recombination reaction rates and radiolytic yields for the water radical fragments need to be measured at high temperature and pressure. Yields for the action of neutron radiation are particularly hard to determine independently because of the beta/gamma field also present in any reactor. In this paper we report the design of an apparatus intended to measure neutron radiolysis yields as a function of temperature and pressure. A new methodology for separation of neutron and beta/gamma radiolysis yields in a mixed radiation field is proposed and demonstrated.

  17. Sistema detector d'incendis WSN

    OpenAIRE

    Domínguez López, Emiliano

    2012-01-01

    Sistema detector d'incendis aprofitant una xarxa de sensors sense fils (WSN) mitjançant un sistema encastat. Sistema detector de incendios aprovechando una red de sensores inalámbricos (WSN) mediante un sistema empotrado.

  18. Sistema detector d'incendis WSN

    OpenAIRE

    Domínguez López, Emiliano

    2012-01-01

    Sistema detector d'incendis aprofitant una xarxa de sensors sense fils (WSN) mitjançant un sistema encastat. Sistema detector de incendios aprovechando una red de sensores inalámbricos (WSN) mediante un sistema empotrado.

  19. Calibração visando à fertilização com fósforo para as principais culturas de grãos sob sistema plantio direto no Paraguai Calibration of phosphorus fertilization rates for main grain crops under no-till in Paraguay

    Directory of Open Access Journals (Sweden)

    Martin Maria Cubilla

    2007-12-01

    Full Text Available Atualmente, em torno de 60 % da área de cultivo de grãos do Paraguai está sob sistema plantio direto (SPD. Com a expansão desse sistema conservacionista no país, surgiram questionamentos quanto à adequação das recomendações de fertilizantes, especialmente de P, pois elas foram elaboradas com base em experimentos realizados sob sistema convencional de preparo de solo e com defasagem de tempo de 15 anos. O principal objetivo deste trabalho foi gerar recomendações atualizadas de adubação fosfatada para as culturas de trigo, milho e soja sob SPD. Para isso, no período de 2003 a 2005 foram realizados experimentos de calibração em rede, abrangendo sete diferentes locais na região oriental do Paraguai. Esses experimentos foram realizados sob SPD em solos com diferentes históricos de sistemas de manejo, texturas e níveis de fertilidade, em regiões representativas da produção de grãos. O delineamento experimental foi de blocos ao acaso com parcelas subdivididas, com três repetições. As parcelas principais, quando da implantação, foram adubadas com cinco doses de P (0, 50, 100, 200 e 400 kg ha-1 de P2O5, visando à criação de níveis de fertilidade. Após implantação do experimento, no segundo cultivo foram criadas as subparcelas, nas quais foram aplicadas quatro doses de P (0, 40, 80 e 120 kg ha-1 de P2O5. A fonte de P utilizada foi o superfosfato triplo, sendo todas as aplicações realizadas a lanço. O potássio, nitrogênio e calagem foram aplicados uniformemente, em quantidades não limitantes, em todas as parcelas. A amostragem de solo foi feita antes da implantação do experimento e após cada colheita com 10 subamostras, para compor uma amostra por subparcela, sempre na profundidade de 0-10 cm. Neste trabalho, a construção da disponibilidade de P sob SPD foi mais influenciada pelo teor inicial do nutriente e histórico de adubação do que pela textura do solo. Em solos com baixo teor inicial de P e com hist

  20. SISTEMA NACIONAL DE CONTABILIDAD

    OpenAIRE

    Yacsahuache Pasapera, Hernán; Facultad de Ciencias Contables, Universidad Nacional Mayor de San Marcos

    2014-01-01

    La Ley 24680 o ley del Sistema Nacional de Contabilidad determina las funciones, objetivos y estructura de los organismos y Órganos componentes del SNC, instituido por el artículo 145° de la Constitución Política del Perú de 1979, los mecanismos de coordinación de la contabilidad, así como las relaciones con otros organismos del sector público y del sector privado. Determina, además, que es un sistema autónomo, administrativa y funcionalmente, tiene a su cargo la investigación y función de l...

  1. El Sistema inspirerede projekter

    DEFF Research Database (Denmark)

    Holst, Finn; Chemi, Tatiana

    Rapporten er resultat af pilotprojektet ”Forundersøgelse El Sistema DK” gennemført af Ph.D. Finn Holst (DPU, Aarhus Universitet) og Ph.D. Tatiana Chemi (Aalborg Universitet) i 2015. I rapporten indgår desuden bidrag fra Sofie Holm, Sara Fink Søndergaard og Stine Møgelbjerg Johansen. Pilotprojektet...... er gennemført for DMKLs El Sistema-udvalg med støtte fra Statens Kunstfond, Projektstøtteudvalget for Musik....

  2. Sistema Internacional de Medidas

    OpenAIRE

    2015-01-01

    La adopcion del Sistema Intemacional de unidades hace necesario que los profesores y maestros lo conozcan y sepan usarlo.La enseiianza de las ciencias, y en especial la didactica de la fisica, se simplifica con Ia adopcion de un sistema unico de unidades. El estudio de Ia mecanica se facilita notablemente y en los tópicos -de calor solo es necesario presentar el julio en vez de Ia caloria y adoptar la escala Kelvin de temperaturas, en tanto que la óptica no requiere de ningin cambio.

  3. Envejecimiento del sistema cardiovascular

    OpenAIRE

    2005-01-01

    Las principales características del envejecimiento del sistema cardiovascular reflejan cambios anatómicos y estructurales a nivel de la pared de los vasos, la relajación miocárdica, el llenado ventricular y la respuesta a las catecolaminas . Muchos de los cambios funcionales asociados con la edad están relacionados con estos fenómenos. Esta revisión describe los cambios relacionados con el envejecimiento a nivel estructural y funcional del sistema cardiovascular, sus posibles factores etiológ...

  4. SISTEMA NACIONAL DE CONTABILIDAD

    OpenAIRE

    Yacsahuache Pasapera, Hernán; Facultad de Ciencias Contables, Universidad Nacional Mayor de San Marcos

    2014-01-01

    La Ley 24680 o ley del Sistema Nacional de Contabilidad determina las funciones, objetivos y estructura de los organismos y Órganos componentes del SNC, instituido por el artículo 145° de la Constitución Política del Perú de 1979, los mecanismos de coordinación de la contabilidad, así como las relaciones con otros organismos del sector público y del sector privado. Determina, además, que es un sistema autónomo, administrativa y funcionalmente, tiene a su cargo la investigación y función de l...

  5. 太阳模拟器在辐射仪器检测中的应用%APPLICATIONS OF SOLAR SIMULATOR IN THE CALIBRATION AND TEST OF RADIATION INSTRUMENTS

    Institute of Scientific and Technical Information of China (English)

    吕文华; 莫月琴; 杨云

    2001-01-01

    该文主要介绍了由TM-500F太阳模拟器和旋转工作台组成的具有多功能辐射仪器室内检测设备的结构、原理及应用。利用该设备可对太阳辐射测量仪器进行灵敏度的校准,由实验可知,总辐射表室内外灵敏度检定结果非常一致,其误差在±0.6%之内。也可进行余弦、方位响应误差,倾斜误差,非线性误差及响应时间等性能的测定。%To evaluate the solar radiation measurement data and instrument specifications, the new versatile laboratory test facility for solar radiation instruments has been developed. It consists of an available solar simulator and a rotating mechanism with an instrument mount. The spectral distribution is in accordance with Air Mass 1.5 global spectral conditions. Directionally, tilt and non-linearity errors of pyranometers can be tested by using this facility. Satisfactory results have been obtained according to calibration measurements of pyranometers. It is shown that the difference values of the sensitivity are within the range of ±0.6% measured in the outdoor exposure.

  6. Extremity dosimeters characterization and calibration for beta radiation fields to evaluate the personal dose equivalent; Caracterizacao e calibracao de dosimetros de extremidade para feixes de radiacao beta em termos do equivalente de dose pessoal

    Energy Technology Data Exchange (ETDEWEB)

    Malheiros, Emiliane Advincula; Oliveira, Arno Heeren de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear]. E-mail: emilianea@hotmail.com; heeren@nuclear.ufmg.br; Silva, Teogenes Augusto da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)]. E-mail: silvata@cdtn.br

    2002-07-01

    Two extremity personal dosimeters were type tested and calibrated to measure the personal dose equivalent, H{rho}(d), at 0.07 mm depth, at beta particle fields from a {sup 90} Sr+{sup 90} Y radiation source. One dosimeter is a graphite mixed CaSO{sub 4}:Dy thermoluminescent (TL) detector in the Harshaw /Bicron Ext-Rad ring; the other is a LiF:Mg,Ti TL detector in a velcro ring. Type tests were carried out to verify the detection limit, linearity, and the angular dependence of both dosimeters. Dosimeters were used to evaluate the personal dose equivalent of operators who deal with {sup 90} Sr+{sup 90} Y ophthalmic and dermatologic applicators at a beta therapy service. Results suggest that the CaSO{sub 4}:Dy dosimeter is more reliable and adequate for measurements at beta radiation fields than the LiF:Mg,Ti dosimeter which shows a trend to subestimate the values of H{rho}(0.07). Two extremity personal dosimeters were type tested. (author)

  7. Calibrating cosmological radiative transfer simulations with Lyman alpha forest data: Evidence for large spatial UV background fluctuations at z ~ 5.6 - 5.8 due to rare bright sources

    CERN Document Server

    Chardin, Jonathan; Aubert, Dominique; Puchwein, Ewald

    2015-01-01

    We calibrate here cosmological radiative transfer simulation with ATON/RAMSES with a range of measurements of the Lyman alpha opacity from QSO absorption spectra. We find the Lyman alpha opacity to be very sensitive to the exact timing of hydrogen reionisation. Models reproducing the measured evolution of the mean photoionisation rate and average mean free path reach overlap at z ~ 7 and predict an accelerated evolution of the Lyman alpha opacity at z > 6 consistent with the rapidly evolving luminosity function of Lyman alpha emitters in this redshift range. Similar to "optically thin" simulations our full radiative transfer simulations fail, however, to reproduce the high-opacity tail of the Lyman alpha opacity PDF at z > 5. We argue that this is due to spatial UV fluctuations in the post-overlap phase of reionisation on substantially larger scales than predicted by our source model, where the ionising emissivity is dominated by large numbers of sub-L* galaxies. We further argue that this suggests a signific...

  8. El Sistema's Open Secrets

    Science.gov (United States)

    Booth, Eric

    2011-01-01

    In this article, the author talks about Venezuela's national youth orchestra program called El Sistema whose attributes offer a direct challenge to traditional Western music practices. As U.S. classical music--and all "high arts"--struggle to find relevance to more than the small "arts club" percentage of the U.S. populace, El…

  9. El Sistema's Open Secrets

    Science.gov (United States)

    Booth, Eric

    2011-01-01

    In this article, the author talks about Venezuela's national youth orchestra program called El Sistema whose attributes offer a direct challenge to traditional Western music practices. As U.S. classical music--and all "high arts"--struggle to find relevance to more than the small "arts club" percentage of the U.S. populace, El…

  10. (Re)implantation of quality system of LCR (Laboratory for Radiation Sciences) for accreditation in the standard ABNT NBR ISO/IEC 17025:2005; (Re)implantacao do sistema da qualidade do LCR para acreditacao na ABNT NBR ISO/IEC 17025:2005

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Sandro P., E-mail: leite_sp@ig.com.br [Rede Sibratec, Sao Paulo, SP (Brazil); Fernandes, Elisabeth O.; David, Mariano G.; Pires, Evandro J.; Alves, Carlos F.E.; Almeida, Carlos E. [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2014-07-01

    This paper presents preparing procedure of the metrology laboratory (LABMETRO), which belongs Laboratorio de Ciencias Radiologicas of Rio de Janeiro , for postulating accreditation of its services metrology to INMETRO. This process, supported by the Technological Services Network SIBRATEC/FINEP for Radiation Protection and Dosimetry Technological Services, had as one of its aims to avoid possible technical barriers to the purchase services in the area of ionizing radiation laboratories. Accreditation will also enable the integration of services such laboratories in Brazilian Calibration Network (RBC). (author)

  11. Calibration of photographic dosemeters to evaluate the personal equivalent dose, Hp (10), irradiated by different radiation qualities and angles of incidence; Calibracao de dosimetros fotograficos para avaliar o equivalente de dose pessoal, Hp(10), irradiados por diferentes qualidades de radiacao e angulos de incidencia

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, Christiana; Antonio Filho, Joao, E-mail: chsantoro@gmail.com, E-mail: jaf@ufpe.br [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Santos, Marcus Aurelio P.; Goncalves Filho, Luiz Carlos, E-mail: masantos@cnen.gov.br, E-mail: l.filho@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, Pe (Brazil)

    2013-07-01

    To use radiation detectors, should periodically perform tests and calibrations on instruments in order to verify its good functionality. One way to ascertain the quality of the instrument is to conduct a study of the angular dependence of the response of the radiation detectors. The photographic dosimetry has been used widely to quantify the radiation doses and to estimate levels of doses received by workers involved with X-and gamma radiation. Photographic dosimeters are used because provide wide range of exposure and good accuracy. One of the sources of error have been introduced by different irradiation geometries between calibration and measurement in radiation fields used in x-ray and gamma ray sources, therefore, there is a need for an evaluation of the sensitivity of dosimeters with variation of the angle of the incident beam. In this study were tested 190 photographic dosemeters in the Metrology Laboratory of the Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) using the phantom H{sub p} (10), where the dosimeters are evaluated on the basis of the new operational magnitude for individual monitoring, the equivalent personal dose, H{sub p} (10). Angular dependence of these radiation detectors was studied in X radiation fields (in the range of 45 keV energy to 164 keV) and gamma radiation ({sup 137}Cs-662 keV e {sup 60}Co - 1250 keV)

  12. TECHNIQUE OF ESTIMATION OF ERROR IN THE REFERENCE VALUE OF THE DOSE DURING THE LINEAR ACCELERATOR RADIATION OUTPUT CALIBRATION PROCEDURE. PART 1. DEPENDANCE OF THE MECHANICAL PARAMETERS OF LINAC’S GANTRY

    Directory of Open Access Journals (Sweden)

    Y. V. Tsitovich

    2015-01-01

    Full Text Available To ensure the safety of radiation oncology patients needed to provide a consistent functional characteristics of the medical linear electron accelerators, which affect the accuracy of dose delivery. To this end, their quality control procedures, which include the calibration of radiation output of the linear accelerator, the error in determining the dose reference value during which must not exceed 2 %, is provided. The aim is to develop a methodology for determining the error in determining this value, depending on the mechanical charachteristics of the linac’s gantry. To achieve the objectives have been carried out dosimetric measurements of Trilogy S/N 3567 linac dose distributions, on the basis of which dose errors depending on the accuracy setting the zero position of the gantry and the deviation of the gantry rotation isocenter were obtained. It was found that the greatest impact on the value of the error has gantry rotation isocenter deviation in a plane perpendicular to the plane of incidence of the radiation beam (up to 3,64% for the energy of 6 MeV. Dose errors caused by tilting the gantry and its isocenter deviation in the plane of incidence of the beam were highest for 18 MeV energy and reached –0,7 % and –0,9 % respectively. Thus, it is possible to express the results of periodic quality control of the linear accelerator ganty in terms of dose and use them to conduct a comprehensive assessment of the possibility of clinical use of a linear accelerator for oncology patients irradiation in case of development of techniques that allow to analyze the influence of the rest of its technical and dosimetric parameters for error in dose.

  13. Efectos de Activación e Inhibición en el Crecimiento del Coleoptilo y del Sistema Radicular de Semillas de Trigo Provocados por Radiación Láser Ultravioleta Effects of Activation and Inhibition on the Growth of the Coleoptile and on the Root System of Wheat Seeds caused by Infrared Laser Radiation

    Directory of Open Access Journals (Sweden)

    Mauricio Hernández

    2012-01-01

    Full Text Available Se ha investigado los efectos de la radiación láser infrarroja sobre el crecimiento del coleoptilo y del sistema radicular en semillas de trigo de la variedad Náhuatl (Triticum aestivum L. Se usó un láser de diodo con longitud de onda A=980nm y se realizaron quince tratamientos con diferentes densidades de potencia y tiempos de exposición. Cada tratamiento láser se aplicó una vez antes de la siembra en experimentos elaborados bajo condiciones de laboratorio. El análisis estadístico mostró activaciones e inhibiciones importantes en el crecimiento del coleoptilo y del sistema radicular. Los resultados muestran que pese a que el coleoptilo sufrió modificaciones en su crecimiento el sistema radicular fue el más susceptible a la radiación láser, mostrando una activación máxima de 15.2% y una inhibición máxima de 17%.In this study the effects of infrared laser radiation on the growth of coleoptile and root system in wheat seeds Nahuatl variety (Triticum aestivum L were investigated. A laser diode with wavelength A = 980nm was used and fifteen laser treatments were performed with different power densities and exposure times. Vach laser treatment was applied once before sowing in experiments carried on under laboratory conditions. The statistical analysis showed important activations and inhibitions in the growth of coleoptile and root system. The results showed that although the growth of the coleoptile was modified the root system was more susceptible to laser radiation, showing a maximum activation of 15.2% and a maximum inhibition of 17%.

  14. Traceable Pyrgeometer Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Mike; Kutchenreiter, Mark; Reda, Ibrahim; Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Newman, Martina

    2016-05-02

    This poster presents the development, implementation, and operation of the Broadband Outdoor Radiometer Calibrations (BORCAL) Longwave (LW) system at the Southern Great Plains Radiometric Calibration Facility for the calibration of pyrgeometers that provide traceability to the World Infrared Standard Group.

  15. Traceable Pyrgeometer Calibrations

    Energy Technology Data Exchange (ETDEWEB)

    Dooraghi, Mike; Kutchenreiter, Mark; Reda, Ibrahim; Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Newman, Martina

    2016-05-02

    This poster presents the development, implementation, and operation of the Broadband Outdoor Radiometer Calibrations (BORCAL) Longwave (LW) system at the Southern Great Plains Radiometric Calibration Facility for the calibration of pyrgeometers that provide traceability to the World Infrared Standard Group.

  16. Calibration of sound calibrators: an overview

    Science.gov (United States)

    Milhomem, T. A. B.; Soares, Z. M. D.

    2016-07-01

    This paper presents an overview of calibration of sound calibrators. Initially, traditional calibration methods are presented. Following, the international standard IEC 60942 is discussed emphasizing parameters, target measurement uncertainty and criteria for conformance to the requirements of the standard. Last, Regional Metrology Organizations comparisons are summarized.

  17. Calibration facility for environment dosimetry instruments

    Energy Technology Data Exchange (ETDEWEB)

    Bercea, Sorin; Celarel, Aurelia; Cenusa, Constantin [Horia Hulubei National Institute for Physics and Nuclear Engineering, 30 Reactorului St, Magurele, Jud Ilfov, P.O.B. MG-6, RO-077125 (Romania)

    2013-12-16

    In the last ten years, the nuclear activities, as well as the major nuclear events (see Fukushima accident) had an increasing impact on the environment, merely by contamination with radioactive materials. The most conferment way to quickly identify the presence of some radioactive elements in the environment, is to measure the dose-equivalent rate H. In this situation, information concerning the values of H due only to the natural radiation background must exist. Usually, the values of H due to the natural radiation background, are very low (∼10{sup −9} - 10{sup −8} Sv/h). A correct measurement of H in this range involve a performing calibration of the measuring instruments in the measuring range corresponding to the natural radiation background lead to important problems due to the presence of the natural background itself the best way to overlap this difficulty is to set up the calibration stand in an area with very low natural radiation background. In Romania, we identified an area with such special conditions at 200 m dept, in a salt mine. This paper deals with the necessary requirements for such a calibration facility, as well as with the calibration stand itself. The paper includes also, a description of the calibration stand (and images) as well as the radiological and metrological parameters. This calibration facilities for environment dosimetry is one of the few laboratories in this field in Europe.

  18. Calibration facility for environment dosimetry instruments

    Science.gov (United States)

    Bercea, Sorin; Celarel, Aurelia; Cenusa, Constantin

    2013-12-01

    In the last ten years, the nuclear activities, as well as the major nuclear events (see Fukushima accident) had an increasing impact on the environment, merely by contamination with radioactive materials. The most conferment way to quickly identify the presence of some radioactive elements in the environment, is to measure the dose-equivalent rate H. In this situation, information concerning the values of H due only to the natural radiation background must exist. Usually, the values of H due to the natural radiation background, are very low (˜10-9 - 10-8 Sv/h). A correct measurement of H in this range involve a performing calibration of the measuring instruments in the measuring range corresponding to the natural radiation background lead to important problems due to the presence of the natural background itself the best way to overlap this difficulty is to set up the calibration stand in an area with very low natural radiation background. In Romania, we identified an area with such special conditions at 200 m dept, in a salt mine. This paper deals with the necessary requirements for such a calibration facility, as well as with the calibration stand itself. The paper includes also, a description of the calibration stand (and images) as well as the radiological and metrological parameters. This calibration facilities for environment dosimetry is one of the few laboratories in this field in Europe.

  19. Sensitivity of Forward Radiative Transfer Model on Spectroscopic Assumptions and Input Geophysical Parameters at 23.8 GHz and 183 GHz Channels and its Impact on Inter-calibration of Microwave Radiometers

    Science.gov (United States)

    Datta, S.; Jones, W. L.; Ebrahimi, H.; Chen, R.; Payne, V.; Kroodsma, R.

    2014-12-01

    The first step in radiometric inter-calibration is to ascertain the self-consistency and reasonableness of the observed brightness temperature (Tb) for each individual sensor involved. One of the widely used approaches is to compare the observed Tb with a simulated Tb using a forward radiative transfer model (RTM) and input geophysical parameters at the geographic location and time of the observation. In this study we intend to test the sensitivity of the RTM to uncertainties in the input geophysical parameters as well as to the underlying physical assumptions of gaseous absorption and surface emission in the RTM. SAPHIR, a cross track scanner onboard Indo-French Megha-Tropique Satellite, gives us a unique opportunity of studying 6 dual band 183 GHz channels at an inclined orbit over the Tropics for the first time. We will also perform the same sensitivity analysis using the Advance Technology Microwave Sounder (ATMS) 23 GHz and five 183 GHz channels. Preliminary analysis comparing GDAS and an independent retrieved profile show some sensitivity of the RTM to the input data. An extended analysis of this work using different input geophysical parameters will be presented. Two different absorption models, the Rosenkranz and the MonoRTM will be tested to analyze the sensitivity of the RTM to spectroscopic assumptions in each model. Also for the 23.8 GHz channel, the sensitivity of the RTM to the surface emissivity model will be checked. Finally the impact of these sensitivities on radiometric inter-calibration of radiometers at sounding frequencies will be assessed.

  20. sistema Web con JSP

    Directory of Open Access Journals (Sweden)

    César Viloria Núñez

    2014-01-01

    Full Text Available Este artículo presenta el desarrollo de un sistema de información que permite la adquisición y la administración de información relacionada con los signos vitales como la presión arterial, la frecuencia cardiaca y respiratoria, y la saturación de oxígeno en la sangre de un paciente. La implementación del sistema se basa en una solución Web, permitiendo así que médicos especialistas puedan monitorear a sus pacientes desde cualquier punto conectado a la red en tiempo real y, al mismo tiempo, dar indicaciones críticas al personal médico que se encuentra en el lugar con el paciente.

  1. SISTEMA DE MONITORAMENTO AUTOMATIZADO

    Directory of Open Access Journals (Sweden)

    Raiane viana Souza

    2016-11-01

    Full Text Available Atualmente existe uma grande necessidade de ter sistemas que auxiliem no monitoramento de ambientes, por exemplo: uma residência; permitindo assim que o usuário possa controlar e ter acesso a tudo que acontece quando o mesmo estiver ausente. Este projeto propõe realizar o desenvolvimento de um sistema de monitoramento automatizado, cujo objetivo é identificar a presença de pessoas e capturar temperaturas de um ambiente. O sistema é composto por um microcontrolador Arduíno, no qual estará acoplado: uma Webcam, sensores de presença e temperatura e um módulo wifi, que possibilitará o envio dos dados capturados ao servidor web. No protótipo desenvolvido foram implantados todos os recursos definidos com base nos requisitos do usuário, dentre os quais podem-se destacar: permitir detectar a presença de pessoas em ambiente, capturar imagens, capturar temperatura em um intervalo de tempo específico e enviar todos os dados para o servidor; permitir que o usuário visualize as informações capturadas através de um site; gerar relatórios e gráficos com as informações capturadas e permitir que o usuário exporte as informações em formato de arquivo.

  2. Technique for Radiometer and Antenna Array Calibration with Two Antenna Noise Diodes

    Science.gov (United States)

    Srinivasan, Karthik; Limaye, Ashutosh; Laymon, Charles; Meyer, Paul

    2011-01-01

    This paper presents a new technique to calibrate a microwave radiometer and phased array antenna system. This calibration technique uses a radiated noise source in addition to an injected noise sources for calibration. The plane of reference for this calibration technique is the face of the antenna and therefore can effectively calibration the gain fluctuations in the active phased array antennas. This paper gives the mathematical formulation for the technique and discusses the improvements brought by the method over the existing calibration techniques.

  3. SISTEMA PROCESSUAL MISTO (OU MÍTICO SISTEMA PROCESSUAL)

    OpenAIRE

    Cani, Luiz Eduardo

    2014-01-01

    Este artigo demonstra que a existência de um sistema processual misto não passa de um engodo. Para tanto, são abordadas as estruturas dos sistemas processuais acusatório e inquisitório. O método de abordagem é o indutivo e o de procedimento é o comparativo. A metodologia empregada é a de análise e de cruzamento da literatura acerca do tema, apresentando-se as razões porque o chamado sistema processual misto não é, na verdade, um sistema.

  4. Spectral emissivity of surface blackbody calibrators

    DEFF Research Database (Denmark)

    Clausen, Sønnik

    2007-01-01

    The normal spectral emissivity of commercial infrared calibrators is compared with measurements of anodized aluminum samples and grooved aluminum surfaces coated with Pyromark. Measurements performed by FTIR spectroscopy in the wavelength interval from 2 to 20 mu m and at temperatures between 5...... in emissivity using similar materials can be reduced to 0.5-1% by optimizing the coating process and the surface geometry. Results are discussed and an equation for calculation of the equivalent blackbody surface temperature from FTIR spectra is presented, including reflected ambient radiation. It is in most...... cases necessary to correct temperature calibration results for calibrators calibrated at 8-14 mu m to obtain absolute accuracies of 0.1-1 degrees C in other spectral regions depending on the temperature. Uncertainties are discussed and equations are given for the correction of measured radiation...

  5. HPS instrument calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Masse, F.X; Eisenhower, E.H.; Swinth, K.L.

    1993-12-31

    The purpose of this paper is to provide an accurate overview of the development and structure of the program established by the Health Physics Society (HPS) for accrediting instrument calibration laboratories relative to their ability to accurately calibrate portable health physics instrumentation. The purpose of the program is to provide radiation protection professionals more meaningful direct and indirect access to the National Institute of Standards and Technology (NIST) national standards, thus introducing a means for improving the uniformity, accuracy, and quality of ionizing radiation field measurements. The process is designed to recognize and document the continuing capability of each accredited laboratory to accurately perform instrument calibration. There is no intent to monitor the laboratory to the extent that each calibration can be guaranteed by the program; this responsibility rests solely with the accredited laboratory.

  6. Sistemas Silvipastoris Silvipastoral Systems

    Directory of Open Access Journals (Sweden)

    Fernando Salgado Bernardino

    2010-02-01

    Full Text Available

    Apesar das pesquisas com sistemas silvipastoris terem sido iniciadas no final da década de 1970, as informações geradas até hoje não são em grande número. As vantagens advindas de um sistema silvipastoril são inúmeras e devidamente reconhecidas. Pelo fato de ser uma técnica de uso da terra capaz de recuperar ecossistemas alterados pelo mau manejo, estes sistemas, pela integração de atividades agrícolas, pecuárias e silviculturais, passam a representar uma tecnologia que confere maior sustentabilidade que os sistemas tradicionais, nos quais os monocultivos são predominantes. Nos últimos anos, instituições de ensino, pesquisa e extensão do País têm se voltado para o desenvolvimento de tais sistemas. O governo de Minas Gerais, por meio de sua Secretaria de Estado de Agricultura e de órgãos vinculados, vem promovendo a condução de modelos agrossilvipastoris num processo integrado de ocupação do solo, denominado lavoura-pecuária-silvicultura. Apesar dos grandes avanços no conhecimento de culturas anuais e dos componentes arbóreos, principalmente o eucalipto, e de gramíneas forrageiras tolerantes à diminuição da intensidade luminosa, ainda é necessário se comnhecer melhor o manejo do sub-bosque sob os efeitos do pastejo.

     

    doi: 10.4336/2009.pfb.60.77

    Although researches related to silvopastoral systems have been initiated many years ago in Brazil, there are few informations generated until now. The advantages from a silvopastoral system are inumerous and well recognized. By the fact of being a technique of land using capable of recovering several disturbed ecosystems, the silvopastoral systems by the integration of agricultural, cattle, and silvicultural activities represent a technology that can achieve higher sustainability than the traditional systems as the monocultures. Today, research centers in Brazil dedicate great attention to agrossilvopastoral systems. The government of Minas Gerais

  7. Design of a realistic radiation field for the calibration of dosimeters used in interventional radiology cardiology (medical personnel dosimetry); Conception d'un champ de rayonnements realiste pour l'etalonnage des dosimetres utilises en radiologie cardiologie interventionnelle (dosimetrie du personnel medical)

    Energy Technology Data Exchange (ETDEWEB)

    Bordy, J.M.; Daures, J.; Denoziere, M.; Gouriou, J. [CEA Saclay, LIST, Laboratoire National Henri Becquerel, 91 - Gif-sur-Yvette (France); Itie, Ch.; Donadile, L. [Institut de Radioprotection et de Surete Nucleaire (IRSN), 92263 Fontenay-aux-Roses (France); Struelens, L. [Belgian Nuclear Research Centre (SCK.CEN) (Belgium); Schultz, F. [Delft University of Technology, Applied Physics-RRR-RIH, Pays Bas (Netherlands)

    2010-07-01

    The authors present the principle to determine the reference value in terms of individual dose equivalent for a calibration installation specifically designed to emulate a radiation field faced at a workstation during interventional cardiology or radiology. They present the workstation configuration which includes the patient and the surgeon. They report the study of the calibration installation where the patient and surgeon are replaced by 'phantoms', and indicate the various fluence spectra obtained at different locations corresponding to different parts of the human body. They compare the simulated and measured spectra

  8. Calibration and monitoring for crystal calorimetry

    CERN Document Server

    Zhu, Ren Yuan

    2005-01-01

    Crystal calorimetry provides excellent energy resolution in high energy and nuclear physics. The light output of heavy crystal scintillators, however, suffers from not negligible damage in radiation environment. A precision calibration and monitoring thus is crucial for maintaining crystal precision in situ. The performance of calibration and monitoring approaches used by BaBar, CLEO and L3 experiments are presented. The design and construction of a laser- based light monitoring system for CMS PWO calorimeter is also discussed.

  9. The eCDR, a Radiation-Hard 40/80/160/320 Mbit/s CDR with internal VCO frequency calibration and 195 ps programmable phase resolution in 130 nm CMOS

    Science.gov (United States)

    Tavernier, F.; Francisco, R.; Bonacini, S.; Poltorak, K.; Moreira, P.

    2013-12-01

    A clock and data recovery IP, the eCDR, is presented which is intended to be implemented on the detector front-end ASICs that need to communicate with the GBTX by means of e-links. The programmable CDR accepts data at 40, 80, 160 or 320Mbit/s and generates retimed data as well as 40, 80, 160 and 320MHz clocks that are aligned to the retimed data. Moreover, all the outputs have a programmable phase with a resolution of 195ps. An internal calibration mechanism enables the eCDR to lock on incoming data even without the availability of any form of reference clock. The radiation-hard design, integrated in a 130nm CMOS technology, operates at a supply voltage between 1.2V and 1.5V. The power consumption is between 28.5mW and 34.5mW, depending on the settings. The eCDR can achieve a very low RMS jitter below 10ps.

  10. The calibration of the vector polarimeter POLIS

    CERN Document Server

    Beck, C

    2013-01-01

    In this diploma thesis, the calibration of the vector polarimeter POLIS will be described. The instrument is built by the Kiepenheuer-Institut fuer Sonnenphysik (Freiburg/Germany) in cooperation with the High Altitude Observatory (Boulder/USA) and will be operated at the German Vacuum Tower Telescope in Tenerife. The instrument yields simultaneously the polarization state of light in two spectral ranges at 396 nm and 630 nm. The measurement is performed with a rotating retarder, which modulates the incident polarization. The modulation is transformed into a varying intensity through polarizing beamsplitters. The demodulation uses a weighted integration scheme to obtain the full Stokes vector of the radiation. The calibration of the polarimeter is performed through the evaluation of a calibration data set produced with a calibration unit consisting of a linear polarizer and a retarder. The instrumental calibration and the polarimetric model of the telescope are described in detail. This document is an unaltere...

  11. Calibration factors for the SNOOPY - NP-100 neutron dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Moscu, D.F. [Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, L8S 4L8 (Canada)], E-mail: moscudf@mcmaster.ca; McNeill, F.E. [Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario, L8S 4L8 (Canada); Chase, J. [Radiation Protection Division, Ontario Power Generation, Whitby, Ontario, L1N 9E3 (Canada)

    2007-10-15

    Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron dosimeter, manufactured by Canberra Industries Incorporated, is employed in both direct and indirect dosimetry methods. Also known as 'SNOOPY', these detectors undergo calibration, which results in a calibration factor relating the neutron count rate to the ambient dose equivalent rate, using a standard Am-Be neutron source. Using measurements presented in a technical note, readings from the dosimeter for six different neutron fields in six source-detector orientations were used, to determine a calibration factor for each of these sources. The calibration factor depends on the neutron energy spectrum and the radiation weighting factor to link neutron fluence to equivalent dose. Although the neutron energy spectra measured in the CANDU workplace are quite different than that of the Am-Be calibration source, the calibration factor remains constant - within acceptable limits - regardless of the neutron source used in the calibration; for the specified calibration orientation and current radiation weighting factors. However, changing the value of the radiation weighting factors would result in changes to the calibration factor. In the event of changes to the radiation weighting factors, it will be necessary to assess whether a change to the calibration process or resulting calibration factor is warranted.

  12. Sistema psiconeuroendocrino y envejecimiento

    OpenAIRE

    Antón Alvarez, X.; Franco, Andrés; Cacabelos, Ramón

    1990-01-01

    Este trabajo expone los efectos del envejecimiento sobre los distintos ejes del sistema neuroendocrino. El envejecimiento provoca cambios dramáticos en la mayor parte de ellos. Algunas de estas alteraciones van asociadas a los cambios conductuales y al rendimiento mental propios del envejecimiento normal y patológico. El mejor conocimiento del envejecimiento neuroendocrino permitirá en su día emplear fármacos y técnicas derivadas de la neurobiología y la genética molecular en ...

  13. Sistemas constructivos industrializados

    Directory of Open Access Journals (Sweden)

    del Águila, Alfonso

    1996-12-01

    Full Text Available The present article summarizes the main points discussed in three Innovator Buildings Systems sessions, which are about different subjects of Industrialized Building. The first part is about the topic of concrete panels, applied to building flats basically. It is given a historical summary and the general concepts, ending with "INDAGSA BUILDING SYSTEM", which is running several promotions with in Madrid. In the second part it is developed the subject of building with boxes, beginning with general points which are extended to the concept of box, its classification, its historical aspects and its applications. It is continues with a description of the "SET HOME SYSTEM" of boxes of concrete, which is dedicated to industrialization of social housing services and equipments. This part ends with the French system "TRANSLOKO" of big light boxes. Lately, it has made a building for laboratories in Madrid. The last part is dedicated to a new subject in Interior Building, which is the Dry Floor, being detailedly described the "PLADUR" point of view about this.

    El presente artículo resume lo tratado en tres jornadas de Sistemas Constructivos Innovadores, relativos a diversos temas de Construcción Industrializada. En la primera parte se trata el tema de los paneles de hormigón aplicados a la edificación, principalmente a viviendas. Se da una síntesis histórica y esquemática de conceptos generales, para terminar con una descripción del Sistema Constructivo INDAGSA que están realizando numerosas promociones en Madrid. La segunda parte, desarrolla el tema de la construcción con módulos tridimensionales, comenzando por unas consideraciones generales que abarcan el concepto de módulo tridimensional, su clasificación, aspectos históricos y campos de aplicación. Se sigue con una descripción del Sistema SET HOME, de módulos tridimensionales de hormigón, dedicado a la industrialización de servicios e instalaciones en vivienda social

  14. El Sistema Penitenciario Mexicano

    OpenAIRE

    Azaola, Elena; Bergman, Marcelo

    2003-01-01

    Este trabajo describe los rasgos y los problemas que caracterizan al sistema penitenciario mexicano y efectúa un análisis del papel que desempeña dentro del conjunto de las instituciones que tienen por objeto combatir la criminalidad. Se abordan los cambios en la actividad delictiva que han tenido lugar en el país durante la última década y las acciones que llevan a cabo las instituciones de seguridad y justicia para contenerla. Se incluyen los principales resultados y conclusiones de una enc...

  15. Los nudos del sistema

    OpenAIRE

    2000-01-01

    Pieza central del antiguo régimen; pacto, acuerdo o trato con algunos actores decisivos del sistema político susceptible de ser revisado; forma cultural de relaciones de poder o de intercambio; pirámide de organizaciones o estructura sectorial: ¿qué tan invisible sigue siendo, qué tan montada sigue estando la pirámide del corporativismo mexicano antes y después del 2 de julio de 2000? Este fenómeno constituye el eje central de las reflexiones del presente ensayo. En torno al mismo, se pres...

  16. Calibration of space instruments at the Metrology Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Klein, R., E-mail: roman.klein@ptb.de; Fliegauf, R.; Gottwald, A.; Kolbe, M.; Paustian, W.; Reichel, T.; Richter, M.; Thornagel, R.; Ulm, G. [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany)

    2016-07-27

    PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.

  17. Synchrotron Radiation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Studies the effects of UV radiation and X rays on solids, and calibrates X-ray optics, detectors, and instruments.DESCRIPTION: Research focuses on applying...

  18. Controlabilidad de Sistemas Bilineales en el Plano

    OpenAIRE

    Laura Guarachi, Leonardo Ramiro

    2012-01-01

    El objeto principal de este trabajo son los sistemas de ecuaciones diferenciales que dependen de un parámetro u, control del sistema, tales sistemas se llaman sistemas de ecuaciones diferenciales controlables, los cuales, en general, describen procesos dinámicos de fenómenos físicos. Estos procesos se describen mediante sistemas de ecuaciones diferenciales ordinarios (EDO), ecuaciones en diferencias o a través de ecuaciones derivadas parciales. Una clase de sistemas de mucha im...

  19. Trinocular Calibration Method Based on Binocular Calibration

    Directory of Open Access Journals (Sweden)

    CAO Dan-Dan

    2012-10-01

    Full Text Available In order to solve the self-occlusion problem in plane-based multi-camera calibration system and expand the measurement range, a tri-camera vision system based on binocular calibration is proposed. The three cameras are grouped into two pairs, while the public camera is taken as the reference to build the global coordinate. By calibration of the measured absolute distance and the true absolute distance, global calibration is realized. The MRE (mean relative error of the global calibration of the two camera pairs in the experiments can be as low as 0.277% and 0.328% respectively. Experiment results show that this method is feasible, simple and effective, and has high precision.

  20. Solar radiation measurement stations - measurement instruments and signal acquisition system - stations managed by the LABSOLAR; Estacoes solarimetricas - instrumentos de medicao e sistema de aquisicao de sinais - estacoes gerenciadas pelo LABSOLAR

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Samuel Luna de [Santa Catarina Univ., Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica. Lab. de Energia Solar (LABSOLAR)]. E-mail: samuel@emc.ufsc.br

    2000-07-01

    This chapter presents a general description of solar radiation measurement stations stations, measurement instruments, signal acquisition system and the LABSOLAR managed stations at Santa Catarina University, Florianopolis, Brazil.

  1. Sistema seguidor solar microcontrolado

    Directory of Open Access Journals (Sweden)

    Daiane Maria Mendes Duarte

    2015-12-01

    Full Text Available A demanda de energia elétrica é cada vez maior devido ao grande crescimento da população e do novo estilo de vida adotado pela sociedade moderna, cada vez mais industrializada. Nesse sentido, o consumo de energia vem apresentando um crescimento acelerado. Concomitantemente, a sociedade se movimenta no sentido de se conscientizar das alterações ocasionadas na natureza, e, assim, surge a necessidade de novos meios de geração de energia, menos impactantes ao meio ambiente, denominadas energias renováveis. Este artigo vem apresentar um sistema seguidor solar microcontrolado, que possibilita uma maior captação de energia em placas solares, pois as posiciona sempre com sua face voltada para o sol. O sistema de controle é baseado nas equações matemáticas cujos resultados são as posições do sol num dado dia e em uma dada hora. Estas coordenadas são calculadas e resultam no deslocamento da célula fotovoltaica por meio de um motor.

  2. Optimization of a data acquisition and control system for calibration of X rays detectors with usage of computational tools; Otimizacao de um sistema de controle e aquisicao de dados para calibracao de medidores de radiacao X com utilizacao de ferramentas computacionais

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Yklys Santos

    2013-07-01

    The Brazilian standard ABNT ISO/IEC 17025/2005 specifies general requirements for the competence of testing and calibration facilities. One of these requirements states that these facilities must always optimize their processes and thus, uncertainties must be estimated and lowered as much as possible. In order to achieve such goal, the Laboratorio de Calibracao de Instrumentos (LCI), a laboratory responsible for dosimeter calibration at the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN) have acquired some equipment for the LCI's X-Ray calibration system, such as a rotating filter holder, and it has also been developing software in order to provide the best calibration results with lowest external interferences (from the operator, for instance) to diminish the possibilities of error occurrences. A semi-automated LabVIEW-based calibration software has been developed at LCI and it has been subjected to constant testing and improvements so far. The software is divided in two basic modules: one is responsible for calibration of the monitor chamber with a reference standard dosimeter, while the other is used to perform instruments calibrations using the monitor chamber as reference. Several influence quantities have been analyzed and the proper corrections have been added to the software as multiplicative correction factors. The software is not only able to acquire data from all the equipment used in the laboratory, but also it is able to calculate calibration factors and its uncertainties. A later analysis shows how this system has optimized the whole calibration process, lowering the occupational dose, reducing the mean time of calibration, uncertainties and preventing errors caused by the system's users. (author)

  3. Radiometer calibration methods and resulting irradiance differences: Radiometer calibration methods and resulting irradiance differences

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron [National Renewable Energy Laboratory, Golden CO 80401 USA; Sengupta, Manajit [National Renewable Energy Laboratory, Golden CO 80401 USA; Andreas, Afshin [National Renewable Energy Laboratory, Golden CO 80401 USA; Reda, Ibrahim [National Renewable Energy Laboratory, Golden CO 80401 USA; Robinson, Justin [GroundWork Renewables Inc., Logan UT 84321 USA

    2016-10-07

    Accurate solar radiation measured by radiometers depends on instrument performance specifications, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methodologies and resulting differences provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these methods calibrate radiometers indoors and some outdoors. To establish or understand the differences in calibration methodologies, we processed and analyzed field-measured data from radiometers deployed for 10 months at NREL's Solar Radiation Research Laboratory. These different methods of calibration resulted in a difference of +/-1% to +/-2% in solar irradiance measurements. Analyzing these differences will ultimately assist in determining the uncertainties of the field radiometer data and will help develop a consensus on a standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainties will help the accurate prediction of the output of planned solar conversion projects and improve the bankability of financing solar projects.

  4. Cryogenic Blackbody-Radiation Calibration Source

    Science.gov (United States)

    Burkett, Cecil G., Jr.; Daryabeigi, Kamran

    1993-01-01

    Operating temperatures range from ambient down to minus 100 degrees C. V-grooved front face of source body blackened and recessed in black sleeve. Semiairtight chamber that houses source purged with dry nitrogen gas to prevent formation of dew or frost at low operating temperature.

  5. Sistemas hamiltonianos ressonantes.

    OpenAIRE

    Marisa Atsuko Nitto

    1999-01-01

    Será analisado, neste trabalho, o problema de ressonância existente entre os corpos celestes, cujos períodos orbitais são comensuráveis na razão p:q, onde p e q são números inteiros positivos. O corpo central será considerado achatado e as excentricidades e inclinações serão quantidades pequenas e não-nulas. O sistema Hamiltoniano ressonante obtido abrange muitos casos que podem ocorrer em problemas de Mecânica Celeste.A análise do problema será feita considerando três classes particulares de...

  6. Sistema Presidencial Mexicano"

    Directory of Open Access Journals (Sweden)

    David Pantoja Morán

    2005-01-01

    Full Text Available En este artículo, el autor aborda el origen doctrinal de las dimensiones institucionales y constitucionales del sistema presidencial-constitucional mexicano para tratar de encontrar ahí los posibles orígenes o explicaciones del éxito o fracaso de este tipo de régimen político. Para ello, se recupera la relevancia y significado de la constitución de 1824 para la vida nacional —desde entonces hasta nuestros días— a fin de comprender muchos de los orígenes de los aciertos y de los errores en el diseño de nuestra constitución vigente así como de la forma presidencial de gobierno, a saber, el principio de legitimidad dual y el de la rigidez o separación rígida de los Poderes.

  7. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  8. The calibration of PIXIE

    Science.gov (United States)

    Fixsen, D. J.; Chuss, D. T.; Kogut, Alan; Mirel, Paul; Wollack, E. J.

    2016-07-01

    The FIRAS instrument demonstrated the use of an external calibrator to compare the sky to an instrumented blackbody. The PIXIE calibrator is improved from -35 dB to -65 dB. Another significant improvement is the ability to insert the calibrator into either input of the FTS. This allows detection and correction of additional errors, reduces the effective calibration noise by a factor of 2, eliminates an entire class of systematics and allows continuous observations. This paper presents the design and use of the PIXIE calibrator.

  9. Calibration of a plastic detector PVT of large dimensions for the detection gamma radiation; Calibracion de un detector plastico de PVT de grandes dimensiones para la deteccion de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Armenteros Carmona, J. C.; Suarez navarro, M. J.; Gonzalez-gonzalez, J. A.; Pujol, L.

    2011-07-01

    This article describes the development work on the porch RadSentry Canberra brand that uses 2 plastic scintillation detectors PVT large (172 x 32 x 4 cm). In this paper we present the different calibration necessary for the proper functioning of equipment: channel-energy calibration, energy resolution, and efficiency-energy.

  10. Calibration of Geodetic Instruments

    Directory of Open Access Journals (Sweden)

    Marek Bajtala

    2005-06-01

    Full Text Available The problem of metrology and security systems of unification, correctness and standard reproducibilities belong to the preferred requirements of theory and technical practice in geodesy. Requirements on the control and verification of measured instruments and equipments increase and the importance and up-to-date of calibration get into the foreground. Calibration possibilities of length-scales (of electronic rangefinders and angle-scales (of horizontal circles of geodetic instruments. Calibration of electronic rangefinders on the linear comparative baseline in terrain. Primary standard of planar angle – optical traverse and its exploitation for calibration of the horizontal circles of theodolites. The calibration equipment of the Institute of Slovak Metrology in Bratislava. The Calibration process and results from the calibration of horizontal circles of selected geodetic instruments.

  11. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  12. Method and apparatus for calibrating spectrophotometers

    OpenAIRE

    Schreutelkamp, F.H.

    2003-01-01

    The present invention relates to a method of calibrating spectrophotometers by placing one or more filters in the light path of the spectrophotometer and measuring the amount of radiation by means of a detector. The present invention furthermore relates to an apparatus to be used with such a method.

  13. La estructura del sistema hegeliano

    OpenAIRE

    Léonard, André; Universidad de Lovaina

    2014-01-01

    Como lo expresa su título, este artículo no pretende exponer el contenido del sistema hegeliano sino el esquema del pensamiento que es inherente a la filosofía hegeliana y que aparece invariable, bajo modos distintos, en cada una de las diferentes exposiciones que hace Hegel de su sistema. El autor toma como base para su trabajo la exposición del sistema hegeliano que aparece en la última edición de la Enciclopedia de las Ciencias Filosóficas (1830). Apoyado en la teoría hegeliana del silogis...

  14. Sistema de control de riego

    OpenAIRE

    Sáez González, Javier

    2016-01-01

    Programación de un sistema capaz de controlar un sistema de riego mediante el microcontrolador Arduino. Dicho sistema se ha programado en la plataforma Simulink y se han llevado a cabo simulaciones del mismo para confirmar su correcto funcionamiento. Las simulaciones realizadas se basan en datos obtenidos de informes meteorológicos diarios que nos dan una idea de las posibles necesidades de riego en diferentes regiones de España. Realización de un estudio de diversos factores que influyen en ...

  15. Adequacy and adjustment of electromechanical elements of a X radiation generator for automation of system of additional filtration; Adequacao e ajuste dos elementos eletromecanicos de um gerador de radiacao X para automacao do sistema de filtracao adicional

    Energy Technology Data Exchange (ETDEWEB)

    Alves Junior, Iremar; Santos, Lucas dos; Potiens, Maria da Penha A.; Vivolo, Vitor, E-mail: iremarjr@usp.b, E-mail: lucas.se@usp.b, E-mail: mppalbu@ipen.b, E-mail: vivolo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper dimensioned the filter wheel components and the adequacy of additional filtrations for the implantation of the OTW automated system with complete replacement of previous used filtration by new set of machine-made filters to be used as the qualities already implanted at the Instrument Calibration Laboratory of the IPEN, Sao Paulo, Brazil. In the sequence, it was performed the measurements of kerma i the air in each quality to be used as reference values

  16. HIRDLS instrument radiometric calibration black body targets

    Science.gov (United States)

    Hepplewhite, Christopher L.; Watkins, Robert E. J.; Row, Frederick; Barnett, John J.; Peters, Daniel M.; Palmer, Christopher W. P.; Wolfenden, Roger; Djotni, Karim; Arter, Philip I.

    2003-11-01

    The pre-launch calibration of the HIRDLS instrument took place in a dedicated facility at the University of Oxford. One aspect of this calibration was the determination of the response of the instrument to black body radiation. This was achieved with the use of purpose built full aperture black body targets which were mounted in the vacuum chamber together with all of the calibration equipment. Special attention was placed on the absolute knowledge of the emission from these targets. This was done through a combination of thermometric sensor calibration traceable to the International Temperature Standard (ITS-90), surface emission measurements, cavity design and modeling and controlling the stray light sources in the vacuum chamber. This paper describes the design requirements, implementation and performance achieved.

  17. Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas; Sistema de avaliacao de desempenho em radioprotecao das industrias convencionais brasileiras nas areas de medidores nucleares e radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joyra Amaral dos

    1999-08-01

    This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting its irregularities, automatically improving its services. The number of industries which have obtained satisfactory performance in both areas is below 70%, both in administrative and operational aspects. Such number can be considered a low one as it is radiation protection. The procedures propose in this work aim to improve such a situation. (author)

  18. Calibration beams at the SSC (Superconducting Super Collider)

    Energy Technology Data Exchange (ETDEWEB)

    Autin, A.; Edwards, H. (Superconducting Super Collider Lab., Dallas, TX (USA)); Bensinger, J.R. (Superconducting Super Collider Lab., Dallas, TX (USA) Brandeis Univ., Waltham, MA (USA)); Baller, B.; Browning, F.; Coleman, R.; Cooper, J.; Cossairt, D.; Kula, L.; Malensek, A.; Stefanski, R.; Stutte, L. (Fermi National Accelerator Lab., Batavia, IL (USA))

    1989-04-30

    This paper discusses the following topics on the Superconducting Super Collider: beam specification at calibration halls; high energy booster options with tunnels to surface; switchyard; six beams with high and low power options; switchyard optics for both high and low energy transport; secondary beams; wide band beams; radiation shielding; tagging system; and test and calibration halls.

  19. Preliminary evaluation of a Neutron Calibration Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Alvarenga, Talysson S.; Neves, Lucio P.; Perini, Ana P.; Sanches, Matias P.; Mitake, Malvina B.; Caldas, Linda V.E., E-mail: talvarenga@ipen.br, E-mail: lpneves@ipen.br, E-mail: aperini@ipen.br, E-mail: msanches@ipen.br, E-mail: mbmitake@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Federico, Claudio A., E-mail: claudiofederico@ieav.cta.br [Instituto de Estudos Avancados (IEAv/DCTA), Sao Jose dos Campos, SP (Brazil). Dept. de Ciencia e Tecnologia Aeroespacial

    2013-07-01

    In the past few years, Brazil and several other countries in Latin America have experimented a great demand for the calibration of neutron detectors, mainly due to the increase in oil prospection and extraction. The only laboratory for calibration of neutron detectors in Brazil is localized at the Institute for Radioprotection and Dosimetry (IRD/CNEN), Rio de Janeiro, which is part of the IAEA SSDL network. This laboratory is the national standard laboratory in Brazil. With the increase in the demand for the calibration of neutron detectors, there is a need for another calibration services. In this context, the Calibration Laboratory of IPEN/CNEN, Sao Paulo, which already offers calibration services of radiation detectors with standard X, gamma, beta and alpha beams, has recently projected a new calibration laboratory for neutron detectors. In this work, the ambient equivalent dose rate (H⁎(10)) was evaluated in several positions inside and around this laboratory, using Monte Carlo simulation (MCNP5 code), in order to verify the adequateness of the shielding. The obtained results showed that the shielding is effective, and that this is a low-cost methodology to improve the safety of the workers and evaluate the total staff workload. (author)

  20. Calibration of the COBE FIRAS instrument

    Science.gov (United States)

    Fixsen, D. J.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Mather, J. C.; Massa, D. L.; Meyer, S. S.

    1994-01-01

    The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite was designed to accurately measure the spectrum of the cosmic microwave background radiation (CMBR) in the frequency range 1-95/cm with an angular resolution of 7 deg. We describe the calibration of this instrument, including the method of obtaining calibration data, reduction of data, the instrument model, fitting the model to the calibration data, and application of the resulting model solution to sky observations. The instrument model fits well for calibration data that resemble sky condition. The method of propagating detector noise through the calibration process to yield a covariance matrix of the calibrated sky data is described. The final uncertainties are variable both in frequency and position, but for a typical calibrated sky 2.6 deg square pixel and 0.7/cm spectral element the random detector noise limit is of order of a few times 10(exp -7) ergs/sq cm/s/sr cm for 2-20/cm, and the difference between the sky and the best-fit cosmic blackbody can be measured with a gain uncertainty of less than 3%.

  1. Variability among polysulphone calibration curves

    Energy Technology Data Exchange (ETDEWEB)

    Casale, G R [University of Rome ' La Sapienza' , Physics Department, P.le A. Moro 2, I-00185, Rome (Italy); Borra, M [ISPESL - Istituto Superiore per la Prevenzione E la Sicurezza del Lavoro, Occupational Hygiene Department, Via Fontana Candida 1, I-0040 Monteporzio Catone (RM) (Italy); Colosimo, A [University of Rome ' La Sapienza' , Department of Human Physiology and Pharmacology, P.le A. Moro 2, I-00185, Rome (Italy); Colucci, M [ISPESL - Istituto Superiore per la Prevenzione E la Sicurezza del Lavoro, Occupational Hygiene Department, Via Fontana Candida 1, I-0040 Monteporzio Catone (RM) (Italy); Militello, A [ISPESL - Istituto Superiore per la Prevenzione E la Sicurezza del Lavoro, Occupational Hygiene Department, Via Fontana Candida 1, I-0040 Monteporzio Catone (RM) (Italy); Siani, A M [University of Rome ' La Sapienza' , Physics Department, P.le A. Moro 2, I-00185, Rome (Italy); Sisto, R [ISPESL - Istituto Superiore per la Prevenzione E la Sicurezza del Lavoro, Occupational Hygiene Department, Via Fontana Candida 1, I-0040 Monteporzio Catone (RM) (Italy)

    2006-09-07

    Within an epidemiological study regarding the correlation between skin pathologies and personal ultraviolet (UV) exposure due to solar radiation, 14 field campaigns using polysulphone (PS) dosemeters were carried out at three different Italian sites (urban, semi-rural and rural) in every season of the year. A polysulphone calibration curve for each field experiment was obtained by measuring the ambient UV dose under almost clear sky conditions and the corresponding change in the PS film absorbance, prior and post exposure. Ambient UV doses were measured by well-calibrated broad-band radiometers and by electronic dosemeters. The dose-response relation was represented by the typical best fit to a third-degree polynomial and it was parameterized by a coefficient multiplying a cubic polynomial function. It was observed that the fit curves differed from each other in the coefficient only. It was assessed that the multiplying coefficient was affected by the solar UV spectrum at the Earth's surface whilst the polynomial factor depended on the photoinduced reaction of the polysulphone film. The mismatch between the polysulphone spectral curve and the CIE erythemal action spectrum was responsible for the variability among polysulphone calibration curves. The variability of the coefficient was related to the total ozone amount and the solar zenith angle. A mathematical explanation of such a parameterization was also discussed.

  2. Distributed Radio Interferometric Calibration

    CERN Document Server

    Yatawatta, Sarod

    2015-01-01

    Increasing data volumes delivered by a new generation of radio interferometers require computationally efficient and robust calibration algorithms. In this paper, we propose distributed calibration as a way of improving both computational cost as well as robustness in calibration. We exploit the data parallelism across frequency that is inherent in radio astronomical observations that are recorded as multiple channels at different frequencies. Moreover, we also exploit the smoothness of the variation of calibration parameters across frequency. Data parallelism enables us to distribute the computing load across a network of compute agents. Smoothness in frequency enables us reformulate calibration as a consensus optimization problem. With this formulation, we enable flow of information between compute agents calibrating data at different frequencies, without actually passing the data, and thereby improving robustness. We present simulation results to show the feasibility as well as the advantages of distribute...

  3. En portada SISTEMA RESPIRATORIO

    Directory of Open Access Journals (Sweden)

    Andrés J. Flores Alés,

    2005-10-01

    Full Text Available La sección “En portada” de este mes está dedicada a los agentes infecciosos y al diagnóstico de algunas de las enfermedades respiratorias más habituales en los animales de compañía, estacando la relevancia adquirida por el diagnóstico mediante la obtención de de imágenes en este campo. También se hace incapie en la actuación que debe llevar a cabo elínico ante una urgencia respiratoria La obtención de imágenes por radiología o endoscopia son dos de las técnicas diagnósticas que más ayudan a dilucidar el proceso respiratorio que sufre un paciente. Sobre el momento en el que se encuentra el diagnóstico por imagen de las patologías del sistema respiratorio en veterinaria nos habla a continuación Andrés J. Flores.

  4. SISTEMAS INMUNES ALTERNATIVOS

    Directory of Open Access Journals (Sweden)

    LUIS F. CADAVID

    2011-01-01

    Full Text Available El sistema inmune en animales es una red compleja de moléculas, células y tejidos que de manera conjunta mantienen la integridad fisiológica y genética de los organismos. Convencionalmente se ha considerado la existencia de dos clases de inmunidad, la innata y la adaptativa. La primera es ancestral, con variabilidad limitada y baja discriminación, mientras que la segunda es altamente variable, específica y restringida a vertebrados mandibulados. La inmunidad adaptativa se basa en receptores de antígeno que se rearreglan somáticamente para generar una diversidad casi ilimitada de moléculas. Este mecanismo de recombinación somática muy probablemente emergió como consecuencia de un evento de transferencia horizontal de transposones y transposasas bacterianas en el ancestro de los vertebrados mandibulados. El reciente descubrimiento en vertebrados no mandibulados e invertebrados de mecanismos alternativos de inmunidad adaptativa, sugiere que en el transcurso de la evolución distintos grupos animales han encontrado soluciones alternativas al problema del reconocimiento inmunológico.

  5. The Science of Calibration

    Science.gov (United States)

    Kent, S. M.

    2016-05-01

    This paper presents a broad overview of the many issues involved in calibrating astronomical data, covering the full electromagnetic spectrum from radio waves to gamma rays, and considering both ground-based and space-based missions. These issues include the science drivers for absolute and relative calibration, the physics behind calibration and the mechanisms used to transfer it from the laboratory to an astronomical source, the need for networks of calibrated astronomical standards, and some of the challenges faced by large surveys and missions.

  6. Modeling of beams in a treatment planning system for external radiation with the help of external tool; Modelado de haces en un sistema de planificacion de tratamientos de radioterapia externa con la ayuda de herramientas externas

    Energy Technology Data Exchange (ETDEWEB)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-07-01

    In this paper we attempt a statistical analysis as directed Protocol Control Systems Quality Planning Radiation Therapy published by the Spanish Society of Medical Physics. Also performed an analysis with the parameter gamma (Low et al.), Which is represented on the graph, allowing an overview of the goodness of fit intuitively.

  7. Micoses do sistema nervoso

    Directory of Open Access Journals (Sweden)

    Carlos da Silva Lacaz

    1947-03-01

    Full Text Available As micoses do sistema nervoso central não têm merecido atenção cuidadosa dos neurologistas. Elas afetam o neuraxe em diferente percentagem: a granulomatose criptocóccica (torulose é a mais freqüente, seguindo-se a actinomicose; a granulomatose paracoccidióidica só excepcionalmente determina lesões meningoencefálicas. Do ponto de vista clínico, as neuromicoses podem ser divididas em duas formas: tumorais encefalomedulares e meningíticas. Estas predominam sobre as tumorais, das quais são mais freqüentes as de localização encefálica. Não são raros os quadros mistos, meningoencetálicos. As formas tumorals encefálicas abrangem vários tipos anátomo-patológicos - abscesso, granuloma, nódulos e cistos - sendo mais comuns os dois primeiros, todos êles produzindo o quadro clinico da síndrome hipertensiva intracraniana. As formas meningomedulares, em geral, são secundárias às lesões ósseas vertebrais, sendo a actinomicose, por ser a mais osteófila, a micose que mais freqüentemente atinge a medula. Nestes casos, o quadro clínico da síndrome compressiva é o mais comum. As meninges participam do processo fúngico, na maior parte dos casos; as manifestações clínicas variam desde o simples meningismo, até as meningites purulentas e meningoencefalites graves, havendo a possibilidade de se formarem aracnoidites císticas, ependimites e bloqueios ventriculares, do aqueduto ou mesmo do canal raquidiano. O diagnóstico das micoses do sistema nervoso central é comumente um "achado de autópsia". Somente a verificação do cogumelo no líquor e o seu isolamento permitem um diagnóstico seguro. Outros dados liquóricos, quando bem interpretados com os achados clínicos e neurológicos, orientam o analista na pesquisa do agente fúngico. O quadro anátomo-patológico nada tem de caraterístico, a não ser a presença do agente parasitário e só o seu encontro firma o diagnóstico. Examinamos 25 casos de granulomatose

  8. Blastomicose do sistema nervoso

    Directory of Open Access Journals (Sweden)

    Horácio M. Canelas

    1951-09-01

    Full Text Available Os autores chamam a atenção sôbre os erros de diagnóstico nos casos de neuroblastomicose, seja nas formas meningoencefálicas, seja nas tumorais. São focalizadas a paracoccidioidose e a criptococose. Depois de caracterizarem clìnicamente a paracoccidioidose, acentuam a raridade das formas nervosas (1,2% dos casos dessa micose autopsiados no Departamento de Anatomia Patológica da Faculdade de Medicina da Universidade de São Paulo. Pela revisão da literatura foi verificado haver apenas 12 casos registrados. 0 caso de Casiello e Klass é o único em que o diagnóstico foi feito em vida; os demais, ou constituem achado de necropsia, ou foram inesperadamente revelados pelo exame histopatológico realizado após intervenções cirúrgicas. Os autores registram 2 casos de paracoccidioidose do sistema nervoso. No primeiro, tratava-se de meningomielorra-diculite crônica, sendo o parasito identificado no escarro; o segundo era portador de síndrome de compressão medular, cuja patogenia é discutida pelos autores, tendo sido a etiologia paracoccidióidica comprovada pelo exame da polpa e biópsia ganglionares. Considerações clínicas sôbre a criptococose precedem o relato de um caso de meningoencefalomielite subaguda, no qual fôra feito em vida o diagnóstico de paracoccidioidose, pelo exame micológico do liqüido cefalorraqueano; êste paciente, embora medicado com doses maciças de sulfa e tiossemicarbarsona, veio a falecer, tendo o exame anátomo-patológico revelado tratar-se, na realidade, de lesões nervosas produzidas pelo Crypíococcus neo-formans. Nos três casos era incisivo o caráter neurocirúrgico da sintomatologia. Entretanto, ante o diagnóstico de paracoccidioidose, foi instituído tratamento pelas sulfas, vacina específica e tiossemicarbarsona. Os resultados foram excelentes no caso 2, em que a terapêutica pôde ser instituída mais precocemente; melhoras também foram obtidas no caso 1. No caso 3, foram verificadas

  9. Calibration of burnup monitor installed in Rokkasho Reprocessing Plant

    Energy Technology Data Exchange (ETDEWEB)

    Oeda, Kaoru; Naito, Hirofumi; Hirota, Masanari [Japan Nuclear Fuel Co. Ltd., Rokkasho, Aomori (Japan); Natsume, Koichiro [Isogo Engineering Center, Toshiba Corporation, Yokohama, Kanagawa (Japan); Kumanomido, Hironori [Nuclear Engineering Laboratory, Toshiba Corporation, Kawasaki, Kanagawa (Japan)

    2000-06-01

    Rokkasho Reprocessing Plant uses burnup credit for criticality control at the Spent Fuel Storage Facility (SFSF) and the Dissolution Facility. A burnup monitor measures nondestructively burnup value of a spent fuel assembly and guarantees the credit for burnup. For practical reasons, a standard radiation source is not used in calibration of the burnup monitor, but the burnup values of many spent fuel assemblies are measured based on operator-declared burnup values. This paper describes the concept of burnup credit, the burnup monitor, and the calibration method. It is concluded, from the results of calibration tests, that the calibration method is valid. (author)

  10. Suggested isosbestic wavelength calibration in clinical analyses.

    Science.gov (United States)

    Hoxter, G

    1979-01-01

    I recommend the use of isosbestic points for conveniently checking the wavelength scale of spectrophotometers in the ultraviolet and visible regions. Colorimetric pH indicators, hemoglobin derivatives, and other radiation-absorbing substances that are convertible into stable isomers of different absorption spectra provide a means for calibrating many different wavelengths by comparing the absorptivities of these isomers in equimolar solutions. The method requires no special precautions and results are independent of substance concentration and temperature between 4 and 45 degrees C. Isosbestic calibration may be important for (e.g.) coenzyme-dependent dehydrogenase activity determinations and in quality assurance programs.

  11. Handheld temperature calibrator

    National Research Council Canada - National Science Library

    Martella, Melanie

    2003-01-01

    ... you sign on. What are you waiting for? JOFRA ETC Series dry-block calibrators from AMETEK Test & Calibration Instruments, Largo, FL, are small enough to be handheld and feature easy-to-read displays, multiple bore blocks, programmable test setup, RS-232 communications, and software. Two versions are available: the ETC 125A that ranges from -10[degrees]C to 125[d...

  12. OLI Radiometric Calibration

    Science.gov (United States)

    Markham, Brian; Morfitt, Ron; Kvaran, Geir; Biggar, Stuart; Leisso, Nathan; Czapla-Myers, Jeff

    2011-01-01

    Goals: (1) Present an overview of the pre-launch radiance, reflectance & uniformity calibration of the Operational Land Imager (OLI) (1a) Transfer to orbit/heliostat (1b) Linearity (2) Discuss on-orbit plans for radiance, reflectance and uniformity calibration of the OLI

  13. Calibration and features of air-kerma length product meters.

    Science.gov (United States)

    Merimaa, K; Tapiovaara, M; Kosunen, A; Toroi, P

    2012-12-01

    Pencil-type air-kerma length product meters are generally used for quality control and radiation exposure measurements in computed tomography. To ensure reliable results, these meters should be calibrated so that measurements are traceable to international standards. Suitable calibration procedures, together with the properties of these meters, were examined and compared with the international standards and recommendations. The calibration procedure and setup used in this study were slightly modified compared with international recommendations. The special collimator system was found to cause less scatter than similar setups in earlier studies. The energy dependence of the meter response was investigated for several types of meters with standard radiation qualities. With most tested meter types, the total variation due to energy dependence was importance of a proper calibration. The response of one semiconductor meter type varied up to 8 % when rotating the meter around its axis; this should be taken into account when making calibrations with a static setup.

  14. WFPC2 Polarization Calibration

    Science.gov (United States)

    Biretta, J.; McMaster, M.

    1997-12-01

    We derive a detailed calibration for WFPC2 polarization data which is accurate to about 1.5%. We begin by computing polarizer flats, and show how they are applied to data. A physical model for the polarization effects of the WFPC2 optics is then created using Mueller matricies. This model includes corrections for the instrumental polarization (diattenuation and phase retardance) of the pick-off mirror, as well as the high cross-polarization transmission of the polarizer filter. We compare this model against the on-orbit observations of polarization calibrators, and show it predicts relative counts in the different polarizer/aperture settings to 1.5% RMS accuracy. We then show how this model can be used to calibrate GO data, and present two WWW tools which allow observers to easily calibrate their data. Detailed examples are given illustrationg the calibration and display of WFPC2 polarization data. In closing we describe future plans and possible improvements.

  15. Sandia WIPP calibration traceability

    Energy Technology Data Exchange (ETDEWEB)

    Schuhen, M.D. [Sandia National Labs., Albuquerque, NM (United States); Dean, T.A. [RE/SPEC, Inc., Albuquerque, NM (United States)

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  16. Development and application of a dosimetric methodology of therapeutic X radiation beams using a tandem system; Desenvolvimento e aplicacao de metodologia dosimetrica de feixes terapeuticos de raios X com sistema tandem

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, Carla Eri

    2001-07-01

    In radiotherapy the use of orthovoltage X radiation beams is still recommended; to obtain satisfactory results, a periodic control is necessary to check the performance of the ionization chambers and the radiation beams characteristics. This control is performed by using standard dosimetric procedures, as for example the determination of half-value layers and the absorbed dose rates. A Tandem system was established in this work using a pair of ionization chambers (a thimble type and a superficial type) used for measures in a medical institution, in substitution to the routine conventional procedure of determination of half-value layers using absorbers. The results obtained show the application of this method in dosimetric procedures of orthovoltage beams (radiotherapy) as a complement for a quality control program. (author)

  17. Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements

    NARCIS (Netherlands)

    van der Graaf, E. R.; Limburg, J.; Koomans, R. L.; Tijs, M.

    2011-01-01

    The calibration of scintillation detectors for gamma radiation in a well characterized setup can be transferred to other geometries using Monte Carlo simulations to account for the differences between the calibration and the other geometry. In this study a calibration facility was used that is const

  18. Monte Carlo based calibration of scintillation detectors for laboratory and in situ gamma ray measurements

    NARCIS (Netherlands)

    van der Graaf, E. R.; Limburg, J.; Koomans, R. L.; Tijs, M.

    The calibration of scintillation detectors for gamma radiation in a well characterized setup can be transferred to other geometries using Monte Carlo simulations to account for the differences between the calibration and the other geometry. In this study a calibration facility was used that is

  19. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt; Medicion de curvas de extrapolacion para el patron secundario de radiacion beta Nr. 86 calibrado en rapidez de dosis absorbida para tejido equivalente por el Physikalisch Technische Bundesanstalt

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T

    1988-10-15

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  20. Segment Based Camera Calibration

    Institute of Scientific and Technical Information of China (English)

    马颂德; 魏国庆; 等

    1993-01-01

    The basic idea of calibrating a camera system in previous approaches is to determine camera parmeters by using a set of known 3D points as calibration reference.In this paper,we present a method of camera calibration in whih camera parameters are determined by a set of 3D lines.A set of constraints is derived on camea parameters in terms of perspective line mapping.Form these constraints,the same perspective transformation matrix as that for point mapping can be computed linearly.The minimum number of calibration lines is 6.This result generalizes that of Liu,Huang and Faugeras[12] for camera location determination in which at least 8 line correspondences are required for linear computation of camera location.Since line segments in an image can be located easily and more accurately than points,the use of lines as calibration reference tends to ease the computation in inage preprocessing and to improve calibration accuracy.Experimental results on the calibration along with stereo reconstruction are reported.

  1. Un sistema desconocido pero internacional

    OpenAIRE

    2008-01-01

    Se presenta en este trabajo un estudio sobre el Sistema Internacional de Unidades (SI) en la etapa de Educación Secundaria (13 a 18 años), cuyo objetivo es comprobar si el alumnado conoce las siete magnitudes y unidades fundamentales, que manejan habitualmente en el aula. A partir del currículum de ciencias se han analizado las posibles causas de las deficiencias encontradas en las magnitudes fundamentales y derivadas. Los resultados muestran que el sistema a pesar de ser inter...

  2. Sistema de salud de Brasil

    OpenAIRE

    Víctor Becerril Montekio; Guadalupe Medina; Rosana Aquino

    2011-01-01

    En este trabajo se describe el sistema de salud de Brasil, que está compuesto por un sector público que cubre alrededor de 75% de la población y un creciente sector privado que ofrece atención a la salud al restante 25% de los brasileños. El sector público está constituido por el Sistema Único de Salud (SUS) y su financiamiento proviene de impuestos generales y contribuciones sociales recaudadas por los tres niveles de gobierno (federal, estatal y municipal). El SUS presta servicios de manera...

  3. Sistema de coordenadas para AR

    OpenAIRE

    Aguiar Cabello, Arnau

    2012-01-01

    Este proyecto realiza un estudio sobre las diferentes opciones referentes a la Realidad Aumentada, como primera parte. La Realidad Aumentada es una tecnología que en los últimos años ha experimentado un gran desarrollo. La Realidad Aumentada consiste en sobreponer información virtual con la ya existente realidad física. Como segunda parte, se escoge una de estas opciones, NyARToolkit, y se explica el funcionamiento del sistema de coordenadas basado en marcadores. El sistema basado en marca...

  4. Algunos Hechos Estilizados del Sistema Bancario Peruano

    OpenAIRE

    Espino, Freddy

    2013-01-01

    Estima el tipo de relación que existe entre las principales variables del sistema bancario (colocaciones y depósitos) y las variables macroeconómicas que afectan el desempeño del sistema bancario.

  5. Site Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    This report describes the site calibration carried out at Østerild, during a given period. The site calibration was performed with two Windcube WLS7 (v1) lidars at ten measurements heights. The lidar is not a sensor approved by the current version of the IEC 61400-12-1 [1] and therefore the site...... calibration with lidars does not comply with the standard. However, the measurements are carried out following the guidelines of IEC 61400-12-1 where possible, but with some deviations presented in the following chapters....

  6. Lidar to lidar calibration

    DEFF Research Database (Denmark)

    Fernandez Garcia, Sergio; Villanueva, Héctor

    This report presents the result of the lidar to lidar calibration performed for ground-based lidar. Calibration is here understood as the establishment of a relation between the reference lidar wind speed measurements with measurement uncertainties provided by measurement standard and corresponding...... lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from the reference lidar measurements are given for information only....

  7. Lidar to lidar calibration

    DEFF Research Database (Denmark)

    Georgieva Yankova, Ginka; Courtney, Michael

    This report presents the result of the lidar to lidar calibration performed for ground-based lidar. Calibration is here understood as the establishment of a relation between the reference lidar wind speed measurements with measurement uncertainties provided by measurement standard and corresponding...... lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from the reference lidar measurements are given for information only....

  8. Sistemas de control moderno volumen II: sistemas de tiempo discreto

    OpenAIRE

    Fernández del Busto, Ricardo; Ramírez Mendoza, Ricardo A.

    2014-01-01

    El objetivo del eBook es iniciar al estudiante en los conceptos de los sistemas de control en tiempo discreto de tal manera que el alumno pueda entender los temas y complementarlos con los contenidos de libros de texto clásicos, ya sea para autoestudio o desarrollo de tareas.

  9. Calibration Fixture For Anemometer Probes

    Science.gov (United States)

    Lewis, Charles R.; Nagel, Robert T.

    1993-01-01

    Fixture facilitates calibration of three-dimensional sideflow thermal anemometer probes. With fixture, probe oriented at number of angles throughout its design range. Readings calibrated as function of orientation in airflow. Calibration repeatable and verifiable.

  10. MAGNETIC GRADIOMETRY: Instrumentation, Calibration and Applications

    DEFF Research Database (Denmark)

    Merayo, Jose Maria Garcia

    is to be used in the forthcoming satellites CHAMP and SAC-C. Linearity, thermal, radiation, dynamic and calibration tests are carried out to qualify the magnetometer in order to ensure state-of-the-art performance with subnanotesla precision. The overall calibration of the gradiometer yields an omnidirectional...... absolute accuracy of 93pT/m.The scalar calibration of a vector magnetometer is explained thoroughly. The novel method is simple and it represents the most robust and unique way to estimate the characterizing 9 parameters of a vector magnetometer. Its power relies on the linearization of the parametrization...... and offers the possibility of separating the geomagnetic field sources.By using tensor algebra the spherical harmonic expansion of the magnetic field in a curl free region and its associated gradient tensor are derived. This differential tensor quantity is then expressed by spherical coordinates...

  11. Sistema de incendios inalámbrico

    OpenAIRE

    Menéndez Muñiz, Sergio

    2012-01-01

    Sistema de detección de incendios inalámbrico basado en dispositivos "motes" para la monitorización del estado del sistema, detección y reconocimiento de alarmas. Sistema de detecció d'incendis sense fils basat en dispositius "motes" per a la monitorització de l'estat del sistema, detecció i reconeixement d'alarmes.

  12. Sistema de incendios inalámbrico

    OpenAIRE

    Menéndez Muñiz, Sergio

    2012-01-01

    Sistema de detección de incendios inalámbrico basado en dispositivos "motes" para la monitorización del estado del sistema, detección y reconocimiento de alarmas. Sistema de detecció d'incendis sense fils basat en dispositius "motes" per a la monitorització de l'estat del sistema, detecció i reconeixement d'alarmes.

  13. El sistema tributario japonés

    OpenAIRE

    Yoshiyasu Okada

    2002-01-01

    Este documento primeramente trata las tendencias recientes y el estado actual del sistema tributario japonés como antecedentes. Luego resume los impuestos principales y describe el actual sistema. Finalmente trata los incentivos tributarios y los aspectos internacionales del sistema japonés.

  14. El sistema tributario japonés

    OpenAIRE

    Yoshiyasu Okada

    2002-01-01

    Este documento primeramente trata las tendencias recientes y el estado actual del sistema tributario japonés como antecedentes. Luego resume los impuestos principales y describe el actual sistema. Finalmente trata los incentivos tributarios y los aspectos internacionales del sistema japonés.

  15. Polymer matrices obtained by ionizing radiation for using in controlled drug delivery systems; Matrizes polimericas obtidas mediante radiacao ionizante para sua utilizacao como sistemas de liberacao controlada de farmacos

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia

    1998-07-01

    Two kinds of controlled drug delivery system were obtained by gamma radiation induced polymerization. One of the system was obtained from an acrylic derivative of acetaminophen (40-hydroxyacetanilide), by copolymerization of 4-(acryloyloxy) acetanilide and N,N-dimethylacrylamide (DMAA) in dimethylformamide solution with 0,16 kGy/h dose rate and 54 Gy dose. The values of reactivity rate, r-D{sub MAA} = 0,31 {+-} 0,02 e r{sub AOA} -0,07 {+-} 0,12, were determined by Fineman-Ross method. The acetaminophen hydrolysis was carried out in alkaline and enzymatic (trypsin) media. Another kind of drug delivery system studied was solvent controlled type, being the drug immobilized in the hydrogel,. The hydrogels prepared by radiation polymerization of acryloyl-L-propine methylester (A-Pro-OMe) with 10 Gy dose, showed thermosensible property, swelling or shrinking in water with decreased or increased temperatures. The hydrogels were obtained with different crosslink density, trimethylolpropane trimethacrylate, and the monomers N, N-dimethyl acrylamide (DMAA) and 2-cyanoethyl acrylate to study the influence of the composition in the drug delivery rate. It was verified that the porous size besides being a characteristic of the matrix composition, it was also temperature dependent (thermosensible). The analgesic drug acetaminophen was immobilized by entrapment and by physical adsorption into the hydrogels matrices for 'in vitro' study. The insulin was immobilized by adsorption for 'in vivo' study. (author)

  16. Responsivity Calibration of Pyroelectric Terahertz Detectors

    CERN Document Server

    Berry, Christopher W; Jarrahi, Mona

    2014-01-01

    There has been a significant advancement in terahertz radiation sources in the past decade, making milliwatt terahertz power levels accessible in both continuous-wave and pulsed operation. Such high-power terahertz radiation sources circumvent the need for cryogenic-cooled terahertz detectors such as semiconductor bolometers and necessitate the need for new types of calibrated, room-temperature terahertz detectors. Among various types of room-temperature terahertz detectors, pyroelectric detectors are one of the most widely used detectors, which can offer wide dynamic range, broad detection bandwidth, and high sensitivity levels. In this article, we describe the calibration process of a commercially available pyroelectric detector (Spectrum Detector, Inc, SPI-A-65 THz), which incorporates a 5 mm diameter LiTaO3 detector with an organic terahertz absorber coating.

  17. Calibrating nacelle lidars

    DEFF Research Database (Denmark)

    Courtney, Michael

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report...... presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail. The first of these is a line of sight calibration method in which both lines of sight (for a two beam lidar) are individually calibrated...... a representative distribution of radial wind speeds. An alternative method is to place the nacelle lidar on the ground and incline the beams upwards to bisect a mast equipped with reference instrumentation at a known height and range. This method will be easier and faster to implement and execute but the beam...

  18. SRHA calibration curve

    Data.gov (United States)

    U.S. Environmental Protection Agency — an UV calibration curve for SRHA quantitation. This dataset is associated with the following publication: Chang, X., and D. Bouchard. Surfactant-Wrapped Multiwalled...

  19. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  20. SPOTS Calibration Example

    Directory of Open Access Journals (Sweden)

    Patterson E.

    2010-06-01

    Full Text Available The results are presented using the procedure outlined by the Standardisation Project for Optical Techniques of Strain measurement to calibrate a digital image correlation system. The process involves comparing the experimental data obtained with the optical measurement system to the theoretical values for a specially designed specimen. The standard states the criteria which must be met in order to achieve successful calibration, in addition to quantifying the measurement uncertainty in the system. The system was evaluated at three different displacement load levels, generating strain ranges from 289 µstrain to 2110 µstrain. At the 289 µstrain range, the calibration uncertainty was found to be 14.1 µstrain, and at the 2110 µstrain range it was found to be 28.9 µstrain. This calibration procedure was performed without painting a speckle pattern on the surface of the metal. Instead, the specimen surface was prepared using different grades of grit paper to produce the desired texture.

  1. Calibrated Properties Model

    Energy Technology Data Exchange (ETDEWEB)

    C. Ahlers; H. Liu

    2000-03-12

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the ''AMR Development Plan for U0035 Calibrated Properties Model REV00. These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions.

  2. Calibrating nacelle lidars

    OpenAIRE

    Courtney, Michael

    2013-01-01

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail.The first of these is a line of sight...

  3. Scanner calibration revisited.

    Science.gov (United States)

    Pozhitkov, Alexander E

    2010-07-01

    Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2.) reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  4. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  5. TWSTFT Link Calibration Report

    Science.gov (United States)

    2015-09-01

    box calibrator with unknown but constant total delay during a calibration tour Total Delay: The total electrical delay from the antenna phase center...to the UTCp including all the devices/cables that the satellite and clock signals pass through. It numerically equals the sum of all the sub-delays...PTB. To average out the dimnal effects and measurement noise , 5-7 days of continuous measurements is required. 3 Setups at the Lab(k) The setup

  6. Approximation Behooves Calibration

    DEFF Research Database (Denmark)

    da Silva Ribeiro, André Manuel; Poulsen, Rolf

    2013-01-01

    Calibration based on an expansion approximation for option prices in the Heston stochastic volatility model gives stable, accurate, and fast results for S&P500-index option data over the period 2005–2009.......Calibration based on an expansion approximation for option prices in the Heston stochastic volatility model gives stable, accurate, and fast results for S&P500-index option data over the period 2005–2009....

  7. Thoughts on Seeing "El Sistema"

    Science.gov (United States)

    Booth, Eric

    2009-01-01

    The FESNOJIV (the Spanish acronym for the State Foundation for the National System of Youth and Children's Orchestras), more commonly known as "El Sistema," teaches 300,000 of Venezuela's poorest children in the nationwide music learning program. Many begin attending the "nucleo" as early as age two or three, and the vast…

  8. Knowledge Exchange with Sistema Scotland

    Science.gov (United States)

    Allan, Julie; Moran, Nikki; Duffy, Celia; Loening, Gica

    2010-01-01

    This paper reports on a knowledge exchange project, funded by the Scottish Funding Council and undertaken by a group of researchers from three higher education institutions in Scotland and the project partner, Sistema Scotland. This newly established charity is attempting to implement a major programme of social change, developed in Venezuela,…

  9. Thoughts on Seeing "El Sistema"

    Science.gov (United States)

    Booth, Eric

    2009-01-01

    The FESNOJIV (the Spanish acronym for the State Foundation for the National System of Youth and Children's Orchestras), more commonly known as "El Sistema," teaches 300,000 of Venezuela's poorest children in the nationwide music learning program. Many begin attending the "nucleo" as early as age two or three, and the vast majority continue well…

  10. Thoughts on Seeing "El Sistema"

    Science.gov (United States)

    Booth, Eric

    2009-01-01

    The FESNOJIV (the Spanish acronym for the State Foundation for the National System of Youth and Children's Orchestras), more commonly known as "El Sistema," teaches 300,000 of Venezuela's poorest children in the nationwide music learning program. Many begin attending the "nucleo" as early as age two or three, and the vast…

  11. Knowledge Exchange with Sistema Scotland

    Science.gov (United States)

    Allan, Julie; Moran, Nikki; Duffy, Celia; Loening, Gica

    2010-01-01

    This paper reports on a knowledge exchange project, funded by the Scottish Funding Council and undertaken by a group of researchers from three higher education institutions in Scotland and the project partner, Sistema Scotland. This newly established charity is attempting to implement a major programme of social change, developed in Venezuela,…

  12. Energy calibration via correlation

    CERN Document Server

    Maier, Daniel

    2015-01-01

    The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting statistics and a sophisticated data analysis. This work presents an easy to handle energy calibration process which can operate reliably on calibration measurements with low counting statistics. The method uses a parameter based model for the energy calibration and concludes on the optimal parameters of the model by finding the best correlation between the measured pulse-height spectrum and multiple synthetic pulse-height spectra which are constructed with different sets of calibration parameters. A CdTe-based semiconductor detector and the line emissions of an 241 Am source were used to test the performance of the correlation method in terms of systematic calibration errors for different counting statistics. Up to energies of 60 keV systematic errors were measured to be le...

  13. Calibrating nacelle lidars

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, M.

    2013-01-15

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail. The first of these is a line of sight calibration method in which both lines of sight (for a two beam lidar) are individually calibrated by accurately aligning the beam to pass close to a reference wind speed sensor. A testing procedure is presented, reporting requirements outlined and the uncertainty of the method analysed. It is seen that the main limitation of the line of sight calibration method is the time required to obtain a representative distribution of radial wind speeds. An alternative method is to place the nacelle lidar on the ground and incline the beams upwards to bisect a mast equipped with reference instrumentation at a known height and range. This method will be easier and faster to implement and execute but the beam inclination introduces extra uncertainties. A procedure for conducting such a calibration is presented and initial indications of the uncertainties given. A discussion of the merits and weaknesses of the two methods is given together with some proposals for the next important steps to be taken in this work. (Author)

  14. Analysis of radiometer calibration effects with TOUCHSTONE

    Science.gov (United States)

    Stanley, William D.

    1990-01-01

    The microwave circuit analysis program TOUCHSTONE is used to study two effects of importance in radiometer calibration. The two effects are impedance mismatches at the antenna-air and cold load-air interfaces and dissipatives losses, which radiate thermal noise into the system. The results predicted by TOUCHSTONE are shown to be in very close agreement with earlier results obtained by purely analytical methods. The techniques used in establishing the circuit models and in processing the resulting data are described in detail.

  15. Calibration and monitoring of spectrometers and spectrophotometers.

    Science.gov (United States)

    Frings, C S; Broussard, L A

    1979-06-01

    We have delineated some of the factors affecting the performance of spectrometers and spectrophotometers in the clinical laboratory and have presented some of the methods for verifying that these instruments are functioning properly. At a minimum, every laboratory should perform periodic inspections of spectrometric functions to check wavelength calibration, linearity of detector response, and stray radiation. Only through such an inspection program can a laboratory ensure that these instruments are not contributing to inaccurate analytical results.

  16. Drug delivery system prepared by ionizing radiation of the N,N-dimethyl acrylamide with acryloyloxy-acetanilide copolymerization; Sistema de liberacao de droga obtido via radiacao ionizante pela copolimerizacao do N,N-dimetilacrilamida com 4-acriloiloxiacetanilida

    Energy Technology Data Exchange (ETDEWEB)

    Martellini, Flavia; Higa, Olga Z. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil); Queiroz, Alvaro A.A. de [Escola Federal de Engenharia de Itajuba, MG (Brazil); Rodighiero, Paolo [Universidade de Padova (Italy). Inst. de Ciencias Farmaceuticas

    1995-12-31

    Radiation induced polymerization has been used in biomaterials used in systems which such as drug delivery (DDS). This work describes the copolymerization of the monomers by gamma rays N,N-dimethyl acrylamide (DMAA) and acryloyloxy-acetanilide (AOA) for the immobilization of paracetamol, an analgesic and anti thermic drug. Dimethylformamide solutions were used in two concentrations of DMAA and AOA (F{sub DMAA/AOA} = 0,85/015 and 0,70/0,30, where F = molar fraction in the monomer feed). The samples were irradiated in the dose range of 30-800 Gy. The copolymer poly(DMAA-co-AOA) characterization was carried out by FTIR and {sup 1}HRMN. The hydrolysis was studied considering the formation of sodium salts of 4-hydroxy acetanilide at different times of treatment using colorimetric assay. (author). 6 refs., 5 figs.

  17. Didactic revision of the operative magnitudes system ICRU for the evaluation of the equivalent dose in radiation external fields; Revision didactica del sistema de magnitudes operativas ICRU para la evaluacion de la dosis equivalente en campos externos de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    In this work is presented in a didactic way the operative magnitudes system ICRU, showing as these magnitudes carry out an appropriate estimate of the effective equivalent doses H{sub E} and the effective dose. The objective is to present the basic concepts of the dosimetry for radiation external fields with purposes of radiological protection, because the assimilation lack and technological development of this dosimetric magnitudes system has persisted for near 50 years, in terms of practice of the radiological protection in Mexico. Also, this system is an essential part of safety basic standards of the IAEA and ICRP recommendations 26, 60, 74 and 103, as well as of the ICRU 25, 39, 43, 51 and 57. (Author)

  18. Las virtudes del sistema binominal

    Directory of Open Access Journals (Sweden)

    John M Carey

    2006-01-01

    Full Text Available El sistema único de elecciones legislativas chileno, en el que cada distrito elige a dos representantes (M=2, ha sido objeto de controversia y de propuestas de reforma, ya que fue impuesto por el régimen autoritario saliente en 1990. La mayor parte de ellas aboga por la llamada mayor proporcionalidad. Este ensayo sostiene que, a pesar de sus orígenes no democráticos, el sistema M=2 ha funcionado relativamente bien respecto a los sistemas empleados en muchos otros países. En particular, M=2 en Chile entrega una mezcla adecuada de representatividad, gobernabilidad y responsabilidad individual del legislador. El ensayo considera varias alternativas para la reforma y perfila algunos problemas potenciales que cada una implicaría. Si se reforma el sistema chileno, entonces el autor recomienda que se haga por pasos incrementales, no fundamentales -un aumento moderado en la magnitud de cada distrito-, pero manteniendo las listas abiertas y no haciendo el salto a un sistema mixto de miembros (SMMChile's unique system of legislative elections, in which each district elects two representatives (M=2, has been subject to controversy and a target for reform proposals since it was imposed on the country by the outgoing authoritarian regime in 1990. Most reform advocates call for greater proportionality. This essay argues that, desipte its undemocratic origins, the M=2 system has performed quite well relative to systems used in many other countries. In particular, M=2 in Chile delivers a reasonable mix of representativeness, governability, and individual legislator accountability. The essay goes on to consider various alternatives for reform and outlines some potential problems each would entail. If the Chilean system is to be reformed, the essay recommends incrementalism - a moderate increase in district magnitude, perhaps, but maintaining open lists, and no change to a mixed-member system (MMS

  19. Sistemas operativos distribuídos

    OpenAIRE

    Bastidas C., Jose Fernando; Carrillo Guzmán, Herbert; Cifuentes C., David Eduardo; Serrano B., María Fernanda; Vargas Cabas, Andres

    2010-01-01

    Desde hace algunos años el uso de los computadores ha cambiado enormemente, debido a la transición, desde los sistemas centralizados que constan de un único CPU, sus periféricos de memoria y algunas terminales, hacia sistemas de cómputo compuestos por un gran número de CPUs, conectados mediante una red de alta velocidad, conocidos como Sistemas Distribuidos. Aunque los sistemas operativos necesarios para estos Sistemas Distribuidos están apenas en etapa de sur...

  20. Introducción al estudio de los sistemas económicos

    OpenAIRE

    García Nossa, Antonio

    2010-01-01

    Interdependencia de los sistemas; Coexistencia de los sistemas; Sucesión y coexistencia; Sistemas históricos y sistemas geopolíticos; Factores cuantitativos y cualitativos de los sistemas; Principios generales de los sistemas.

  1. Calibrating a detector array for in vivo dosimetry beam electron In this work present a set of detectors calibration for measurements in vivo dose at the entrance of the radiation beam in electron beams; Calibracion de un conjunto de detectores para la dosimetria in vivo de haces de electrones

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Jurado, T.; Jornet Sala, N.; Carrasco de Fez, P.; Eudaldo Puell, T.; Latorre Mussoll, A.; Rodriguez Latorre, D.; Ruiz Martinez, A.; Ribas Morales, M.

    2013-07-01

    In particular we have determined the variation in sensitivity of the diode depending on the field size, power, angle of incidence, DFS, temperature and cumulative dose. From these results we provide a methodology for calibrating a diode array for use in routine. The application of correction factors to reading diodes are warranted when the irradiation conditions differ from the reference by the level of tolerance among the expected dose and the dose obtained. (Author)

  2. PPV analysis and tension of spectral peak in an X radiation equipment for dosemeter calibration; Analise do PPV e tensao de pico espectral em um equipamento de raios-X para calibracao de dosimetros

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, P.M.C.; Santana, P.C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem; Lacerda, M.A.S.; Silva, T.A. da, E-mail: pmco@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2014-07-01

    Dosimetry laboratories around the world try to achieve metrology consistency between the X-rays beams for therapy and diagnostic detectors calibration. One of the parameters to characterize X-ray beam is the practical peak voltage (PPV) assessment. In this work were evaluated the PPV and spectral peak voltage in the potential constant X-ray equipment, that result in a mean difference of 1.4 %. (author)

  3. HAWC Timing Calibration

    CERN Document Server

    Huentemeyer, Petra; Dingus, Brenda

    2009-01-01

    The High-Altitude Water Cherenkov (HAWC) Experiment is a second-generation highsensitivity gamma-ray and cosmic-ray detector that builds on the experience and technology of the Milagro observatory. Like Milagro, HAWC utilizes the water Cherenkov technique to measure extensive air showers. Instead of a pond filled with water (as in Milagro) an array of closely packed water tanks is used. The event direction will be reconstructed using the times when the PMTs in each tank are triggered. Therefore, the timing calibration will be crucial for reaching an angular resolution as low as 0.25 degrees.We propose to use a laser calibration system, patterned after the calibration system in Milagro. Like Milagro, the HAWC optical calibration system will use ~1 ns laser light pulses. Unlike Milagro, the PMTs are optically isolated and require their own optical fiber calibration. For HAWC the laser light pulses will be directed through a series of optical fan-outs and fibers to illuminate the PMTs in approximately one half o...

  4. Calibration Under Uncertainty.

    Energy Technology Data Exchange (ETDEWEB)

    Swiler, Laura Painton; Trucano, Timothy Guy

    2005-03-01

    This report is a white paper summarizing the literature and different approaches to the problem of calibrating computer model parameters in the face of model uncertainty. Model calibration is often formulated as finding the parameters that minimize the squared difference between the model-computed data (the predicted data) and the actual experimental data. This approach does not allow for explicit treatment of uncertainty or error in the model itself: the model is considered the %22true%22 deterministic representation of reality. While this approach does have utility, it is far from an accurate mathematical treatment of the true model calibration problem in which both the computed data and experimental data have error bars. This year, we examined methods to perform calibration accounting for the error in both the computer model and the data, as well as improving our understanding of its meaning for model predictability. We call this approach Calibration under Uncertainty (CUU). This talk presents our current thinking on CUU. We outline some current approaches in the literature, and discuss the Bayesian approach to CUU in detail.

  5. Calibration curve to establish the exposure dose at Co{sup 60} gamma radiation; Curva de calibracion para establecer dosis de exposicion a radiacion gamma de Co{sup 60}

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C.; Brena V, M. [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico)

    2000-07-01

    The biological dosimetry is an adequate method for the dose determination in cases of overexposure to ionizing radiation or doubt of the dose obtained by physical methods. It is based in the aberrations analysis produced in the chromosomes. The behavior of leisure in chromosomes is of dose-response type and it has been generated curves in distinct laboratories. Next is presented the curve for gamma radiation produced in the National Institute of Nuclear Research (ININ) laboratory. (Author)

  6. Method of biodosimeter calibration for orbital flight

    Science.gov (United States)

    Vladislav, Petrov

    A biodosimetry method, based on estimation of an absorbed dose on the basis of assessment of unstable aberration frequency in the lymphocytes of human's peripheral blood is used broadly in ground conditions for analysis of accidental exposure to personal and citizens. A calibration curve giving the relationship between aberration frequency (generally dicentrics and centric rings) and an absorbed dose in blood samples is used for assessment of crewmember exposure. As a rule gamma - rays corresponding to character of exposure in such accidents are used for these goals. At the same time the space radiation fields are formed mainly by charged particles for which the character of effect on the body cells and tissues differs strongly from that of gamma - rays. As biodosimetry is a relative method of dose measurement it is necessary to obtain a calibration curve corresponding to the conditions in which the measurements will be performed. That is a calibration curve for space application should give a relationship between aberration frequency and a dose formed by radiation field equal to that on the spacecraft trajectory. The report contains a method of obtaining a calibration curve for a case of an orbital flight on the ISS trajectory. The radiobiological basis of the method consists of relationships between chromosomal aberration frequency in human blood lymphocytes and an absorbed dose of protons with four energies (50 MeV, 150 MeV, 400 MeV, 625 MeV) obtained in the accelerator's experiments. Due to the fact that we had experimental data only for protons the calibration curve was obtained for the proton component on the ISS orbit which is mainly formed by trapped protons. Dose spectrum for this energy distribution of protons was calculated and weighting coefficients for taking into account the input of dose of protons with various energies in forming total frequency of chromosomal aberrations were obtained on its basis. The procedure of obtaining such weighting

  7. Testing and calibration through laser radiation and muon beams of the hadron calorimeter in ATLAS detector; Controle et etalonnage par lumiere laser et par faisceaux de muons du calorimetre hadronique a tuiles scintillantes d'ATLAS

    Energy Technology Data Exchange (ETDEWEB)

    Garde, V

    2003-10-15

    This study is dedicated to the calibration of the hadronic calorimeter (Tilecal) of the ATLAS detector. This detector will be installed on the LHC collider at CERN. The first data will be taken in 2007. This thesis is divided in two parts. The first part is dedicated to the study of the LASER system. A prototype of the final system was studied. It was shown that the stability and the linearity of this prototype are conform to the specification. Several studies were devoted to measurements which can be done on the Tilecal: The relative gain can be calculated and gives the stability of the Tilecal with a resolution of 0.35 %. The number of photoelectrons per charge unit has been calculated. The linearity was checked for a normal range of functioning and was corrected for the functioning at high charge. In both cases it was shown that the non-linearity was smaller than 0.5 %. The second study is devoted to muons beams in test beam periods. These results are used to find a calibration constant. Several problems which come from the difference of size cells are not totally solved. But the resolution of the calibration constant found by this method cannot exceed 2.3%. (author)

  8. TARGETLESS CAMERA CALIBRATION

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2012-09-01

    Full Text Available In photogrammetry a camera is considered calibrated if its interior orientation parameters are known. These encompass the principal distance, the principal point position and some Additional Parameters used to model possible systematic errors. The current state of the art for automated camera calibration relies on the use of coded targets to accurately determine the image correspondences. This paper presents a new methodology for the efficient and rigorous photogrammetric calibration of digital cameras which does not require any longer the use of targets. A set of images depicting a scene with a good texture are sufficient for the extraction of natural corresponding image points. These are automatically matched with feature-based approaches and robust estimation techniques. The successive photogrammetric bundle adjustment retrieves the unknown camera parameters and their theoretical accuracies. Examples, considerations and comparisons with real data and different case studies are illustrated to show the potentialities of the proposed methodology.

  9. Calibration Systems Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Myers, Tanya L.; Broocks, Bryan T.; Phillips, Mark C.

    2006-02-01

    The Calibration Systems project at Pacific Northwest National Laboratory (PNNL) is aimed towards developing and demonstrating compact Quantum Cascade (QC) laser-based calibration systems for infrared imaging systems. These on-board systems will improve the calibration technology for passive sensors, which enable stand-off detection for the proliferation or use of weapons of mass destruction, by replacing on-board blackbodies with QC laser-based systems. This alternative technology can minimize the impact on instrument size and weight while improving the quality of instruments for a variety of missions. The potential of replacing flight blackbodies is made feasible by the high output, stability, and repeatability of the QC laser spectral radiance.

  10. Ibis ground calibration

    Energy Technology Data Exchange (ETDEWEB)

    Bird, A.J.; Barlow, E.J.; Tikkanen, T. [Southampton Univ., School of Physics and Astronomy (United Kingdom); Bazzano, A.; Del Santo, M.; Ubertini, P. [Istituto di Astrofisica Spaziale e Fisica Cosmica - IASF/CNR, Roma (Italy); Blondel, C.; Laurent, P.; Lebrun, F. [CEA Saclay - Sap, 91 - Gif sur Yvette (France); Di Cocco, G.; Malaguti, E. [Istituto di Astrofisica Spaziale e Fisica-Bologna - IASF/CNR (Italy); Gabriele, M.; La Rosa, G.; Segreto, A. [Istituto di Astrofisica Spaziale e Fisica- IASF/CNR, Palermo (Italy); Quadrini, E. [Istituto di Astrofisica Spaziale e Fisica-Cosmica, EASF/CNR, Milano (Italy); Volkmer, R. [Institut fur Astronomie und Astrophysik, Tubingen (Germany)

    2003-11-01

    We present an overview of results obtained from IBIS ground calibrations. The spectral and spatial characteristics of the detector planes and surrounding passive materials have been determined through a series of calibration campaigns. Measurements of pixel gain, energy resolution, detection uniformity, efficiency and imaging capability are presented. The key results obtained from the ground calibration have been: - optimization of the instrument tunable parameters, - determination of energy linearity for all detection modes, - determination of energy resolution as a function of energy through the range 20 keV - 3 MeV, - demonstration of imaging capability in each mode, - measurement of intrinsic detector non-uniformity and understanding of the effects of passive materials surrounding the detector plane, and - discovery (and closure) of various leakage paths through the passive shielding system.

  11. Radiation analysis devices, radiation analysis methods, and articles of manufacture

    Science.gov (United States)

    Roybal, Lyle Gene

    2010-06-08

    Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.

  12. CP-50 calibration facility radiological safety assessment document

    Energy Technology Data Exchange (ETDEWEB)

    Chilton, M.W.; Hill, R.L.; Eubank, B.F.

    1980-03-01

    The CP-50 Calibration Facility Radiological Safety Assessment document, prepared at the request of the Nevada Operations Office of the US Department of Energy to satisfy provisions of ERDA Manual Chapter 0531, presents design features, systems controls, and procedures used in the operation of the calibration facility. Site and facility characteristics and routine and non-routine operations, including hypothetical incidents or accidents are discussed and design factors, source control systems, and radiation monitoring considerations are described.

  13. Calibration of {sup 133}Ba by Sum-Peak Method

    Energy Technology Data Exchange (ETDEWEB)

    Silva, R.L. da; Delgado, J.U.; Poledna, R.; Trindade, O.L.; Veras, E.V. de; Santos, A.; Rangel, J., E-mail: ronaldo@ird.gov.br, E-mail: delgado@ird.gov.br, E-mail: poledna@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, M.C.M, E-mail: marcandida@yahoo.com.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    A calibration laboratory should have several methods of measurement in order to ensure robustness on the values applied. The National Laboratory for Metrology of Ionizing Radiation, (LNMRI IRD), provides gamma sources of radionuclide in various geometries and standardized in activity with reduced uncertainties. Some absolute and relative methods of calibrations could be used routinely. Relative methods require standards to determine the activity of sample to be calibrated, while the absolute methods do not need, simply make the counting and the calculation of the activity is obtained directly. The great advantage of calibrations of radionuclides by absolute method is the accuracy and low uncertainties. {sup 133}Ba is a radionuclide enough used in research laboratories and calibration of detectors for environmental analysis and, according to the scheme, it decays 100% by electron capture and emits about 14 energy gamma and X-ray lines, forming several coincidences. However, the classical methods of absolute measurement, as coincidence 4 πβ-γ have difficulty to calibrate {sup 133}Ba due to its complex decay scheme. The sum-peak method, developed by Brickman, could allow this calibration. It is used for radionuclide calibration that emits at least two photons in coincidence. Therefore, it was developed a methodology that combines gamma spectrometry technique with sum-peak method to standardize {sup 133}Ba samples. Activity results obtained proved compatible, with uncertainties of less than 1%, and, when compared with other methods of calibration, sum-peak demonstrated the feasibility of this methodology, particularly, for simplicity and effectiveness. (author)

  14. Calibrating Legal Judgments

    Directory of Open Access Journals (Sweden)

    Frederick Schauer

    2017-09-01

    Full Text Available Objective to study the notion and essence of legal judgments calibration the possibilities of using it in the lawenforcement activity to explore the expenses and advantages of using it. Methods dialectic approach to the cognition of social phenomena which enables to analyze them in historical development and functioning in the context of the integrity of objective and subjective factors it determined the choice of the following research methods formallegal comparative legal sociological methods of cognitive psychology and philosophy. Results In ordinary life people who assess other peoplersaquos judgments typically take into account the other judgments of those they are assessing in order to calibrate the judgment presently being assessed. The restaurant and hotel rating website TripAdvisor is exemplary because it facilitates calibration by providing access to a raterrsaquos previous ratings. Such information allows a user to see whether a particular rating comes from a rater who is enthusiastic about every place she patronizes or instead from someone who is incessantly hard to please. And even when less systematized as in assessing a letter of recommendation or college transcript calibration by recourse to the decisional history of those whose judgments are being assessed is ubiquitous. Yet despite the ubiquity and utility of such calibration the legal system seems perversely to reject it. Appellate courts do not openly adjust their standard of review based on the previous judgments of the judge whose decision they are reviewing nor do judges in reviewing legislative or administrative decisions magistrates in evaluating search warrant representations or jurors in assessing witness perception. In most legal domains calibration by reference to the prior decisions of the reviewee is invisible either because it does not exist or because reviewing bodies are unwilling to admit using what they in fact know and employ. Scientific novelty for the first

  15. Iterative Magnetometer Calibration

    Science.gov (United States)

    Sedlak, Joseph

    2006-01-01

    This paper presents an iterative method for three-axis magnetometer (TAM) calibration that makes use of three existing utilities recently incorporated into the attitude ground support system used at NASA's Goddard Space Flight Center. The method combines attitude-independent and attitude-dependent calibration algorithms with a new spinning spacecraft Kalman filter to solve for biases, scale factors, nonorthogonal corrections to the alignment, and the orthogonal sensor alignment. The method is particularly well-suited to spin-stabilized spacecraft, but may also be useful for three-axis stabilized missions given sufficient data to provide observability.

  16. Nociones del Sistema Tributario Mexicano

    Directory of Open Access Journals (Sweden)

    Froylán Balderas Torres

    2012-01-01

    Full Text Available La presente información se encamina a interiorizar al lector en el tema fiscal con palabras sencillas, describiendo en forma sucinta los antecedentes de los tributos, hasta llegar y describir el sistema impositivo actual mexicano, y de ahí estudiar en forma específica el impuesto que tiene más relevancia por la cantidad que se recauda siendo el Impuesto Sobre la Renta.

  17. Sistemas de control en estructuras

    Directory of Open Access Journals (Sweden)

    José Luis Ahumada Villafañe

    2010-01-01

    Full Text Available En el diseño estructural, la capacidad de disipación de energía en elementos que conforman los sistemas resistentes a fuerzas dinámicas, como las impartidas por la actividad sísmica y eólica, es suministrada por un minucioso detallado del acero de refuerzo y dimensiones en las secciones transversales de los elementos. Esta práctica es realizada bajo muchas suposiciones que en algunas ocasiones no corresponden a la realidad, y como es de esperarse, producen resultados inexactos y un desconocimiento del desempeño de la estructura. Por lo anterior es riesgoso confiar el 100% de la capacidad estructural a los elementos sobre todo cuando conforman sistemas estructurales diseñados en zonas de amenaza sísmica alta. En este artículo se presentan los sistemas de control, los cuales son una serie de dispositivos adaptados a las estructuras que absorben gran parte de la energía sísmica y liberan los elementos estructurales en gran porcentaje de la acción sísmica, logrando disminuir en ellas las solicitaciones (fuerzas internas y las respuestas (derivas con el objetivo de conseguir un buen desempeño, limitar el daño y abaratar los costos de reparación de fallas localizadas. Los sistemas de control que se analizarán en el presente artículo se dividen en control pasivo, control activo, control semiactivo y control híbrido.

  18. Calibration method of HLS's sensor used in SSRF

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The site of Shanghai Synchrotron Radiation Facility (SSRF) is of complicated geological conditions, and a system to monitor the uneven subsidence of foundation and key parts (different kinds of magnets) of the accelerators is a necessity. Considering actual conditions of the accelerator structure and the assembling place, a new type of sensor of hydrostatic levelling system (HLS) has been designed. In order to obtain the required measurement accuracy, every HLS's sensor was strictly calibrated. In this paper, we introduce the special calibration method to establish the HLS. The method has been used in the calibration for vessel sensor for SSRF.

  19. Smart Calibration of Excavators

    DEFF Research Database (Denmark)

    Bro, Marie; Døring, Kasper; Ellekilde, Lars-Peter

    2005-01-01

    Excavators dig holes. But where is the bucket? The purpose of this report is to treat four different problems concerning calibrations of position indicators for excavators in operation at concrete construction sites. All four problems are related to the question of how to determine the precise ge...

  20. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    is suggested to cope with the singular design matrix most often seen in chemometric calibration. Furthermore, the proposed algorithm may be generalized to all convex norms like Sigma/beta (j)/(gamma) where gamma greater than or equal to 1, i.e. a method that continuously varies from ridge regression...

  1. Calibrating Communication Competencies

    Science.gov (United States)

    Surges Tatum, Donna

    2016-11-01

    The Many-faceted Rasch measurement model is used in the creation of a diagnostic instrument by which communication competencies can be calibrated, the severity of observers/raters can be determined, the ability of speakers measured, and comparisons made between various groups.

  2. NVLAP calibration laboratory program

    Energy Technology Data Exchange (ETDEWEB)

    Cigler, J.L.

    1993-12-31

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST).

  3. CALIBRATION OF PHOSWICH DETECTORS

    NARCIS (Netherlands)

    LEEGTE, HKW; KOLDENHOF, EE; BOONSTRA, AL; WILSCHUT, HW

    1992-01-01

    Two important aspects for the calibration of phoswich detector arrays have been investigated. It is shown that common gate ADCs can be used: The loss in particle identification due to fluctuations in the gate timing in multi-hit events can be corrected for by a simple procedure using the measured ti

  4. Measurement System & Calibration report

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  5. LOFAR facet calibration

    CERN Document Server

    van Weeren, R J; Hardcastle, M J; Shimwell, T W; Rafferty, D A; Sabater, J; Heald, G; Sridhar, S S; Dijkema, T J; Brunetti, G; Brüggen, M; Andrade-Santos, F; Ogrean, G A; Röttgering, H J A; Dawson, W A; Forman, W R; de Gasperin, F; Jones, C; Miley, G K; Rudnick, L; Sarazin, C L; Bonafede, A; Best, P N; Bîrzan, L; Cassano, R; Chyży, K T; Croston, J H; Ensslin, T; Ferrari, C; Hoeft, M; Horellou, C; Jarvis, M J; Kraft, R P; Mevius, M; Intema, H T; Murray, S S; Orrú, E; Pizzo, R; Simionescu, A; Stroe, A; van der Tol, S; White, G J

    2016-01-01

    LOFAR, the Low-Frequency Array, is a powerful new radio telescope operating between 10 and 240 MHz. LOFAR allows detailed sensitive high-resolution studies of the low-frequency radio sky. At the same time LOFAR also provides excellent short baseline coverage to map diffuse extended emission. However, producing high-quality deep images is challenging due to the presence of direction dependent calibration errors, caused by imperfect knowledge of the station beam shapes and the ionosphere. Furthermore, the large data volume and presence of station clock errors present additional difficulties. In this paper we present a new calibration scheme, which we name facet calibration, to obtain deep high-resolution LOFAR High Band Antenna images using the Dutch part of the array. This scheme solves and corrects the direction dependent errors in a number of facets that cover the observed field of view. Facet calibration provides close to thermal noise limited images for a typical 8 hr observing run at $\\sim$ 5arcsec resolu...

  6. Entropic calibration revisited

    Energy Technology Data Exchange (ETDEWEB)

    Brody, Dorje C. [Blackett Laboratory, Imperial College, London SW7 2BZ (United Kingdom)]. E-mail: d.brody@imperial.ac.uk; Buckley, Ian R.C. [Centre for Quantitative Finance, Imperial College, London SW7 2AZ (United Kingdom); Constantinou, Irene C. [Blackett Laboratory, Imperial College, London SW7 2BZ (United Kingdom); Meister, Bernhard K. [Blackett Laboratory, Imperial College, London SW7 2BZ (United Kingdom)

    2005-04-11

    The entropic calibration of the risk-neutral density function is effective in recovering the strike dependence of options, but encounters difficulties in determining the relevant greeks. By use of put-call reversal we apply the entropic method to the time reversed economy, which allows us to obtain the spot price dependence of options and the relevant greeks.

  7. La reforma del sistema electoral chileno

    Directory of Open Access Journals (Sweden)

    Mariela Rubano Lapasta

    2007-01-01

    Full Text Available La modificación del sistema electoral público chileno se ha transformado nuevamente en tema de debate público, después de la Reforma Constitucional de 2005. El Gobierno ha propuesto reformar el sistema electoral, sustituirlo por otro que permita a las minorías tener representación en el Congreso. Se abordan brevemente los sistemas electorales en el derecho comparado, en especial el caso chileno, evaluando las ventajas y desventajas del sistema electoral nacional. Se propone recurrir al mecanismo de primarias a fin de elegir a los candidatos. Se concluye que no hay ningún sistema ideal, importa más las características del sistema político y no tanto el método electoral con el cual se eligen a los representantes.

  8. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John F. Schabron; Joseph F. Rovani; Susan S. Sorini

    2007-03-31

    The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005, requires that calibration of mercury continuous emissions monitors (CEMs) be performed with NIST-traceable standards. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The traceability protocol will be written by EPA. Traceability will be based on the actual analysis of the output of each calibration unit at several concentration levels ranging from about 2-40 ug/m{sup 3}, and this analysis will be directly traceable to analyses by NIST using isotope dilution inductively coupled plasma/mass spectrometry (ID ICP/MS) through a chain of analyses linking the calibration unit in the power plant to the NIST ID ICP/MS. Prior to this project, NIST did not provide a recommended mercury vapor pressure equation or list mercury vapor pressure in its vapor pressure database. The NIST Physical and Chemical Properties Division in Boulder, Colorado was subcontracted under this project to study the issue in detail and to recommend a mercury vapor pressure equation that the vendors of mercury vapor pressure calibration units can use to calculate the elemental mercury vapor concentration in an equilibrium chamber at a particular temperature. As part of this study, a preliminary evaluation of calibration units from five vendors was made. The work was performed by NIST in Gaithersburg, MD and Joe Rovani from WRI who traveled to NIST as a Visiting Scientist.

  9. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  10. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-07-01

    Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

  11. Heliostat kinematic system calibration using uncalibrated cameras

    Science.gov (United States)

    Burisch, Michael; Gomez, Luis; Olasolo, David; Villasante, Cristobal

    2017-06-01

    The efficiency of the solar field greatly depends on the ability of the heliostats to precisely reflect solar radiation onto a central receiver. To control the heliostats with such a precision accurate knowledge of the motion of each of them modeled as a kinematic system is required. Determining the parameters of this system for each heliostat by a calibration system is crucial for the efficient operation of the solar field. For small sized heliostats being able to make such a calibration in a fast and automatic manner is imperative as the solar field potentially contain tens or even hundreds of thousands of them. A calibration system which can rapidly recalibrate a whole solar field would also allow reducing costs. Heliostats are generally designed to provide stability over a large period of time. Being able to relax this requirement and compensate any occurring error by adapting parameters in a model, the costs of the heliostat can be reduced. The presented method describes such an automatic calibration system using uncalibrated cameras rigidly attached to each heliostat. The cameras are used to observe targets spread out through the solar field; based on this the kinematic system of the heliostat can be estimated with high precision. A comparison of this approach to similar solutions shows the viability of the proposed solution.

  12. Modelo de sistemas tutores inteligentes multiagente

    OpenAIRE

    Ferrer, Alejandro; Vallejos, Félix Anibal; Jiménez Rey, Elizabeth Miriam; Grossi, María Delia; Servetto, Arturo Carlos; Perichinsky, Gregorio

    2006-01-01

    Se presenta una línea de investigación del Proyecto de la Facultad de Ingeniería de la Universidad de Buenos Aires I015: Manufactura Integrada por Computadora en Sistemas Complejos para el Desarrollo Social, Industrial y de Tecnología. Se introduce conceptos básicos de los campos en los que incursiona esta línea de investigación: Sistemas Tutores Inteligentes (STI) y Sistemas Multiagentes (SMA). Se describe los aspectos esenciales que se deben considerar en el modelado de un sistema ...

  13. Mercury Calibration System

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Joseph Rovani; Mark Sanderson; Ryan Boysen; William Schuster

    2009-03-11

    U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on

  14. Automation of dosimeters calibration for radiotherapy in secondary dosimetric calibration laboratory of the CPHR; Automatizacion de la calibracion de dosimetros de radioterapia en el laboratorio secundario de calibracion dosimetrica del CPHR

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, Andy L. Romero; Lores, Stefan Gutierrez, E-mail: c19btm@frcuba.co.cu [Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-11-01

    This paper presents the design and implementation of an automated system for measurements in the calibration of reference radiation dosimeters. It was made a software application that performs the acquisition of the measured values of electric charge, calculated calibration coefficient and automates the calibration certificate issuance. These values are stored in a log file on a PC. The use of the application improves control over the calibration process, helps to humanize the work and reduces personnel exposure. The tool developed has been applied to the calibration of dosimeters radiation patterns in the LSCD of the Centro de Proteccion e Higiene de las Radiaciones, Cuba.

  15. Radiation therapy physics

    CERN Document Server

    Hendee, William R; Hendee, Eric G

    2013-01-01

    The Third Edition of Radiation Therapy Physics addresses in concise fashion the fundamental diagnostic radiologic physics principles as well as their clinical implications. Along with coverage of the concepts and applications for the radiation treatment of cancer patients, the authors have included reviews of the most up-to-date instrumentation and critical historical links. The text includes coverage of imaging in therapy planning and surveillance, calibration protocols, and precision radiation therapy, as well as discussion of relevant regulation and compliance activities. It contains an upd

  16. Reflexiones sobre los sistemas silvopastoriles

    Directory of Open Access Journals (Sweden)

    R. O Russo

    Full Text Available El objetivo de este análisis es reflexionar acerca de modelos integrados de producción ganadera familiar y extensiva, más estables y sustentables, en los que se integre el componente leñoso, que contribuye a la reducción de gases con efecto invernadero y favorece la mitigación del cambio climático. Para ello se hizo una revisión de conceptos referentes a la integración de la actividad forestal en la ganadería, como alternativa viable de sistema de producción. Se parte del criterio de que los sistemas silvopastoriles (SSP, dentro de los agroforestales, son agroecosistemas en los que se asocia un componente arbóreo con uno herbáceo (pasturas naturales o mejoradas y otro pecuario (ganado en un mismo sitio, donde existen interacciones biológicas entre estos y se maximiza el uso de la tierra. También se describe cómo se agrupan los SSP; sus oportunidades desde los puntos de vista económico, productivo, social y ambiental; y los efectos de la interacción entre sus componentes. Este análisis permite plantear que los SSP son producto de la relación entre la biología, la sociedad y la cultura, y en ellos existe una enorme diversidad; asimismo, permiten la reconversión de la ganadería extensiva de muy baja productividad en sistemas más productivos y sostenibles en el tiempo, así como la rehabilitación de las áreas degradadas por ese tipo de ganadería, por la deforestación y por el agotamiento de los suelos.

  17. The Calibration Reference Data System

    Science.gov (United States)

    Greenfield, P.; Miller, T.

    2016-07-01

    We describe a software architecture and implementation for using rules to determine which calibration files are appropriate for calibrating a given observation. This new system, the Calibration Reference Data System (CRDS), replaces what had been previously used for the Hubble Space Telescope (HST) calibration pipelines, the Calibration Database System (CDBS). CRDS will be used for the James Webb Space Telescope (JWST) calibration pipelines, and is currently being used for HST calibration pipelines. CRDS can be easily generalized for use in similar applications that need a rules-based system for selecting the appropriate item for a given dataset; we give some examples of such generalizations that will likely be used for JWST. The core functionality of the Calibration Reference Data System is available under an Open Source license. CRDS is briefly contrasted with a sampling of other similar systems used at other observatories.

  18. Lidar calibration experiments

    DEFF Research Database (Denmark)

    Ejsing Jørgensen, Hans; Mikkelsen, T.; Streicher, J.

    1997-01-01

    A series of atmospheric aerosol diffusion experiments combined with lidar detection was conducted to evaluate and calibrate an existing retrieval algorithm for aerosol backscatter lidar systems. The calibration experiments made use of two (almost) identical mini-lidar systems for aerosol cloud...... detection to test the reproducibility and uncertainty of lidars. Lidar data were obtained from both single-ended and double-ended Lidar configurations. A backstop was introduced in one of the experiments and a new method was developed where information obtained from the backstop can be used in the inversion...... algorithm. Independent in-situ aerosol plume concentrations were obtained from a simultaneous tracer gas experiment with SF6, and comparisons with the two lidars were made. The study shows that the reproducibility of the lidars is within 15%, including measurements from both sides of a plume...

  19. Optical tweezers absolute calibration

    CERN Document Server

    Dutra, R S; Neto, P A Maia; Nussenzveig, H M

    2014-01-01

    Optical tweezers are highly versatile laser traps for neutral microparticles, with fundamental applications in physics and in single molecule cell biology. Force measurements are performed by converting the stiffness response to displacement of trapped transparent microspheres, employed as force transducers. Usually, calibration is indirect, by comparison with fluid drag forces. This can lead to discrepancies by sizable factors. Progress achieved in a program aiming at absolute calibration, conducted over the past fifteen years, is briefly reviewed. Here we overcome its last major obstacle, a theoretical overestimation of the peak stiffness, within the most employed range for applications, and we perform experimental validation. The discrepancy is traced to the effect of primary aberrations of the optical system, which are now included in the theory. All required experimental parameters are readily accessible. Astigmatism, the dominant effect, is measured by analyzing reflected images of the focused laser spo...

  20. Neurocitoma no sistema nervoso central

    Directory of Open Access Journals (Sweden)

    José Torquato Severo

    1973-03-01

    Full Text Available É relatado o caso de uma paciente com 6 anos de idade, hospitalizada com síndrome de hipertensão intracraniana. Após o exame neuro-radiológico que evidenciou processo expansivo frontal direito, a paciente foi submetida à cirurgia, durante a qual ocorreu o óbito. O exame histo-patológico do material retirado durante o ato operatório, permitiu o diagnóstico de neurocitoma, tumor raro no sistema nervoso central.

  1. Calibration Facilities for NIF

    Energy Technology Data Exchange (ETDEWEB)

    Perry, T.S.

    2000-06-15

    The calibration facilities will be dynamic and will change to meet the needs of experiments. Small sources, such as the Manson Source should be available to everyone at any time. Carrying out experiments at Omega is providing ample opportunity for practice in pre-shot preparation. Hopefully, the needs that are demonstrated in these experiments will assure the development of (or keep in service) facilities at each of the laboratories that will be essential for in-house preparation for experiments at NIF.

  2. Mesoscale hybrid calibration artifact

    Science.gov (United States)

    Tran, Hy D.; Claudet, Andre A.; Oliver, Andrew D.

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  3. Astrid-2 SSC ASUMagnetic Calibration

    DEFF Research Database (Denmark)

    Primdahl, Fritz

    1997-01-01

    Report of the inter calibration between the starcamera and the fluxgate magnetometer onboard the ASTRID-2 satellite. This calibration was performed in the night between the 15. and 16. May 1997 at the Lovö magnetic observatory.......Report of the inter calibration between the starcamera and the fluxgate magnetometer onboard the ASTRID-2 satellite. This calibration was performed in the night between the 15. and 16. May 1997 at the Lovö magnetic observatory....

  4. Calibration of the radiation monitors from DESY and SPring-8 at the quasi-mono-energetic neutron beams using 100 and 300 MeV 7Li(p,n) reaction at RCNP in Osaka Japan in November 2014

    Science.gov (United States)

    Leuschner, Albrecht; Asano, Yoshihiro; Klett, Alfred

    2017-09-01

    At the ring cyclotron facility of the Research Center for Nuclear Physics (RCNP) Osaka University, Osaka, Japan a series of measurement campaigns had been continued with quasi mono-energetic neutron beams in November 2014. A 7Li target was bombarded with 100 and 300 MeV protons and the generated neutron beams were directed into a long time-of-flight tunnel at 0 and 25 degrees deflection angle with respect to the proton beam. At a distance of 41 m the cross section of the neutron beam was large enough for the illumination of square meter sized objects like extended range rem-counters. The research institutes SPring-8/RIKEN, Japan, and DESY, Germany, participated in this campaign for the calibration of 4 different types of active ambient dose rate monitors: LB 6411, LB 6411-Pb, LB 6419 and LB 6420. The measurements of their responses are reported and compared with the calculated values.

  5. Calibration of Underwater Sound Transducers

    Directory of Open Access Journals (Sweden)

    H.R.S. Sastry

    1983-07-01

    Full Text Available The techniques of calibration of underwater sound transducers for farfield, near-field and closed environment conditions are reviewed in this paper .The design of acoustic calibration tank is mentioned. The facilities available at Naval Physical & Oceanographic Laboratory, Cochin for calibration of transducers are also listed.

  6. Accurate antenna reflector loss measurements for radiometer calibration budget

    DEFF Research Database (Denmark)

    Skou, Niels

    1996-01-01

    Antenna reflector losses may play an important role in the calibration budget for a microwave radiometer. If the losses are small they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiat...... radiation. The paper describes how such measurements are carried out as well as a suitable experimental set-up. The main reflector of the European Space Agency's MIMR system is used to demonstrate the principle...

  7. Internet-based calibration of a multifunction calibrator

    Energy Technology Data Exchange (ETDEWEB)

    BUNTING BACA,LISA A.; DUDA JR.,LEONARD E.; WALKER,RUSSELL M.; OLDHAM,NILE; PARKER,MARK

    2000-04-17

    A new way of providing calibration services is evolving which employs the Internet to expand present capabilities and make the calibration process more interactive. Sandia National Laboratories and the National Institute of Standards and Technology are collaborating to set up and demonstrate a remote calibration of multifunction calibrators using this Internet-based technique that is becoming known as e-calibration. This paper describes the measurement philosophy and the Internet resources that can provide real-time audio/video/data exchange, consultation and training, as well as web-accessible test procedures, software and calibration reports. The communication system utilizes commercial hardware and software that should be easy to integrate into most calibration laboratories.

  8. Riesgos para el sistema mundial

    Directory of Open Access Journals (Sweden)

    José María Tortosa

    2012-02-01

    Full Text Available Partiendo de varios diagnósticos producidos recientemente sobre los riesgos del sistema mundial, se hace una propia lista de los que parecen ser los diez más importantes, a saber, la cuestión del petróleo, el auge de la China, el desplome de los Estados Unidos, la desconexión de América Latina, la crisis de Naciones Unidas, los nuevos terrorismos, la amenaza nuclear, pandemias, cambio climático y polarización social. Como existe una conexión y retroalimentación entre muchos de ellos, se concluye indicando la posibilidad deque estemos entrando en una etapa particularmente caótica en el sistema mundial.Starting from some recent diagnosis about the risks of the world system, a new list is made with the possible more important ones, namely, tipping point in oil, rise of China, breakdown of the United States, new terrorisms, nuclear threat, pandemics, climatic change and social polarization. As far as a connexion and feedback between these elements can be found, the conclusion points to the possibility of a new era especially chaotic in the world system.

  9. Sistemas residenciales: conceptos y aplicaciones

    Directory of Open Access Journals (Sweden)

    Franu00E7oise Dureau

    2004-01-01

    Full Text Available Luego de volver sobre los orígenes de la noción de sistema residencial familiar en la investigación sobre África y América Latina, el artículo expone las técnicas de recolección desarrolladas en dos encuestas colombianas. El análisis de la morfología espacial de los sistemas residenciales familiares de los Bogotanos pone en evidencia las prácticas pluri-locales de la población, las movilidades que las subtienden y la importancia de la localización en las escogencias residenciales. Con este enfoque, el análisis de las prácticas residenciales se desplaza de la vivienda hacia el acceso a los recursos urbanos localizados: los relacionados con el entorno natural, los producidos por los actores políticos y económicos, pero también aquellos construidos por las prácticas sociales de los habitantes. De esta manera, lo que se propone aquí es una renovación de la lectura de las dinámicas espaciales en términos de territorios y un reconocimiento del habitante como actor pleno de la producción de nuevas configuraciones urbanas.

  10. Los Sistemas tecnológicos Concretos

    OpenAIRE

    2011-01-01

    Usando un enfoque sistémico, se estudian cierto tipo de subsistemas sociales que caracterizan a la sociedad contemporánea. Específicamente se definen aquellos tecnosistemas que realizan el diseño y la ejecución de artefactos y/o sistemas artificiales, los que se denominarán sistemas tecnológicos.

  11. On the calibration of polarimetric Thomson scattering by Raman polarimetry

    Science.gov (United States)

    Giudicotti, L.; Pasqualotto, R.

    2015-12-01

    Polarimetric Thomson scattering (TS) is an alternative method for the analysis of Thomson scattering spectra in which the plasma temperature T e is determined from the depolarization of the TS radiation. This is a relativistic effect and therefore the technique is suitable only for very hot plasmas (T e  >  10 keV) such as those of ITER. The practical implementation of polarimetric TS requires a method to calibrate the polarimetric response of the collection optics carrying the TS light to the detection system, and in particular to measure the additional depolarization of the TS radiation introduced by the plasma-exposed first mirror. Rotational Raman scattering of laser light from diatomic gases such as H2, D2, N2 and O2 can provide a radiation source of predictable intensity and polarization state from a well-defined volume inside the vacuum vessel and is therefore suitable for these calibrations. In this paper we discuss Raman polarimetry as a technique for the calibration of a hypothetical polarimetric TS system operating in the same conditions of the ITER core TS system and suggest two calibration methods for the measurement of the additional depolarization introduced by the plasma-exposed first mirror, and in general for calibrating the polarimetric response of the detection system.

  12. Imaging plates calibration to X-rays

    Science.gov (United States)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  13. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Joseph Rovani; Mark Sanderson

    2008-02-29

    Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The

  14. Self-Calibrating Pressure Transducer

    Science.gov (United States)

    Lueck, Dale E. (Inventor)

    2006-01-01

    A self-calibrating pressure transducer is disclosed. The device uses an embedded zirconia membrane which pumps a determined quantity of oxygen into the device. The associated pressure can be determined, and thus, the transducer pressure readings can be calibrated. The zirconia membrane obtains oxygen .from the surrounding environment when possible. Otherwise, an oxygen reservoir or other source is utilized. In another embodiment, a reversible fuel cell assembly is used to pump oxygen and hydrogen into the system. Since a known amount of gas is pumped across the cell, the pressure produced can be determined, and thus, the device can be calibrated. An isolation valve system is used to allow the device to be calibrated in situ. Calibration is optionally automated so that calibration can be continuously monitored. The device is preferably a fully integrated MEMS device. Since the device can be calibrated without removing it from the process, reductions in costs and down time are realized.

  15. Calibration of the DLP-SC-3300-02 probe

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Breinbjerg, Olav

    This report douments the calibration measurement of the DLP-SC-3300-02 dual-linearly polarized near-field probe. The measurement comprises radiation pattern, diretivity, gain, spetra of spherial wave coefients, polarization charateristis, and complex channel balance at 41 frequencies, as well...

  16. Technical Note: Calibration and validation of geophysical observation models

    NARCIS (Netherlands)

    Salama, M.S.; van der Velde, R.; van der Woerd, H.J.; Kromkamp, J.C.; Philippart, C.J.M.; Joseph, A.T.; O'Neill, P.E.; Lang, R.H.; Gish, T.; Werdell, P.J.; Su, Z.

    2012-01-01

    We present a method to calibrate and validate observational models that interrelate remotely sensed energy fluxes to geophysical variables of land and water surfaces. Coincident sets of remote sensing observation of visible and microwave radiations and geophysical data are assembled and subdivided i

  17. Measurement of small antenna reflector losses for radiometer calibration budget

    DEFF Research Database (Denmark)

    Skou, Niels

    1997-01-01

    Antenna reflector losses play an important role in the calibration budget for a microwave radiometer. If the losses are small, they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiation...

  18. Cross calibration of IRS-P4 OCM satellite sensor

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.; Desa, E.; Mascarenhas, A.A.M.Q.; Matondkar, S.G.P.; Naik, P.; Nayak, S.R.

    The cross calibration of ocean color satellite sensor, IRS-P4 OCM using the radiative transfer code, with SeaWiFS as a reference are presented here. Since the bands of IRS-P4 OCM are identical to those of SeaWiFS and SeaWiFS has been continuously...

  19. Campaign for vicarious calibration of SumbandilaSat in Argentina

    CSIR Research Space (South Africa)

    Vhengani, LM

    2011-07-01

    Full Text Available to estimate Top-Of-Atmosphere (TOA) spectral radiance. A vicarious calibration field campaign was executed in Argentina to support monitoring of the radiometric response of the multispectral imager aboard SumbandilaSat. Results obtained using two Radiative...

  20. CALIBRATED HYDRODYNAMIC MODEL

    Directory of Open Access Journals (Sweden)

    Sezar Gülbaz

    2015-01-01

    Full Text Available The land development and increase in urbanization in a watershed affect water quantityand water quality. On one hand, urbanization provokes the adjustment of geomorphicstructure of the streams, ultimately raises peak flow rate which causes flood; on theother hand, it diminishes water quality which results in an increase in Total SuspendedSolid (TSS. Consequently, sediment accumulation in downstream of urban areas isobserved which is not preferred for longer life of dams. In order to overcome thesediment accumulation problem in dams, the amount of TSS in streams and inwatersheds should be taken under control. Low Impact Development (LID is a BestManagement Practice (BMP which may be used for this purpose. It is a land planningand engineering design method which is applied in managing storm water runoff inorder to reduce flooding as well as simultaneously improve water quality. LID includestechniques to predict suspended solid loads in surface runoff generated over imperviousurban surfaces. In this study, the impact of LID-BMPs on surface runoff and TSS isinvestigated by employing a calibrated hydrodynamic model for Sazlidere Watershedwhich is located in Istanbul, Turkey. For this purpose, a calibrated hydrodynamicmodel was developed by using Environmental Protection Agency Storm WaterManagement Model (EPA SWMM. For model calibration and validation, we set up arain gauge and a flow meter into the field and obtain rainfall and flow rate data. Andthen, we select several LID types such as retention basins, vegetative swales andpermeable pavement and we obtain their influence on peak flow rate and pollutantbuildup and washoff for TSS. Consequently, we observe the possible effects ofLID on surface runoff and TSS in Sazlidere Watershed.

  1. Calibration of ionization chambers in IAEA water phantom; Kalibrering av ionekamre i IAEA-vannfantom

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H.; Mikkelborg, O.

    1995-11-01

    The calibration in a water phantom is realised at the Secondary Standard Dosimetry Laboratory in Norway. The method is valid for chambers used in high energy radiation therapy. The method, setup and corrections in the calibration are described. The absorbed dose to air calibration factor, N{sub D}, will have an uncertainty of {approx}0.8% (k=1). 15 refs., 7 figs., 5 tabs.

  2. Dynamic Torque Calibration Unit

    Science.gov (United States)

    Agronin, Michael L.; Marchetto, Carl A.

    1989-01-01

    Proposed dynamic torque calibration unit (DTCU) measures torque in rotary actuator components such as motors, bearings, gear trains, and flex couplings. Unique because designed specifically for testing components under low rates. Measures torque in device under test during controlled steady rotation or oscillation. Rotor oriented vertically, supported by upper angular-contact bearing and lower radial-contact bearing that floats axially to prevent thermal expansion from loading bearings. High-load capacity air bearing available to replace ball bearings when higher load capacity or reduction in rate noise required.

  3. Radiometric Calibrations, Measurements, and Standards Development at NREL: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Myers, D. R.; Andreas, A.; Stoffel, T.; Reda, I.; Wilcox, S.; Gotseff, P.; Kay, B.

    2001-10-01

    Presented at the 2001 NCPV Program Review Meeting: Radiometric calibrations, measurements, and standards development at NREL. We describe proposed revisions to current reference standard spectral distributions used to evaluate photovoltaic device performance and durability of materials. Improvements in broadband outdoor radiometer calibrations reduce uncertainties in broadband radiometer calibrations. We report a method to quantify the rate of change of broadband radiometer responsivities as a function of integrated exposure to irradiance and thermal energy. The results of applying a vector of calibration factors or responsivities to field data to remove zenith-angle dependent errors in global solar radiation measurements are shown. We report on the relative sensitivity of radiometers to daily versus biweekly cleaning.

  4. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  5. Energy dependence evaluation of the patient dose calibrator

    Science.gov (United States)

    Costa, N. A.; Potiens, M. P. A.

    2014-02-01

    The aim of this paper was to evaluate the energy dependence of the kerma-area product meter Patient Dose Calibrator (PDC). The research was done using the calculation of the coefficient calibration of the air kerma values of different energies that are related to the radiation qualities provided on the International Standard of the International Electrotechnical Commission IEC 61267 for conventional X-rays, mammography and computerized tomography (CT), established at the Calibration Laboratory of IPEN. The calibration was made using reference ionization chambers with traceability to the Primary Laboratory Physikalisch-Technische Bundesanstalt (PTB), Germany. The energy dependence of the PDC was determined and the results showed that the PDC has small energy dependence, less than 6%, for the range of recommended energy while to the mammography range the values were 16% and for CT qualities the dependence was 1%.

  6. Leveraging microwave polarization information for calibration of a land data assimilation system

    Science.gov (United States)

    This letter contributes a new approach to calibrating a tau-omega radiative transfer model coupled to a land surface model with low frequency (< 10 GHz) microwave brightness temperature (TB) observations. The problem of calibrating this system is generally poorlyposed because various parameter combi...

  7. Uniform calibration of night vision goggles and test sets

    Science.gov (United States)

    Eppeldauer, George P.

    2007-10-01

    There are orders of magnitude differences between the ~0.1 % (k=2) uncertainty of NIST reference detector calibrations and the uncertainty of night vision (NV) goggle measurements. NIST developed a night vision radiometer calibration facility including NV radiometer transfer standards. The transfer standards, that propagate the radiance responsivity scale to the military primary standards laboratories, are calibrated against a NIST reference radiometer. The reference radiometer has been calibrated on the NIST Spectral Comparator Facility (SCF) for spectral power and irradiance responsivities. Spectral considerations are discussed to lower the uncertainties of the radiance responsivity scale transfer to the test sets and then to the goggles. Since direct determination of the final uncertainties in goggle calibrations and measurements is difficult, models have been made to estimate the most important uncertainty components based on individual spectral measurements of the applied source distributions and radiometer spectral responsivities. It is also shown, that because of source spectral mismatch problems, the goggle measurement uncertainty at applications can be much higher than at calibration. A suggestion is being made to mimic the no-moon (stars only) night sky radiation distribution using several LEDs in the test-sets to decrease the large spectral mismatch errors. A broad-band correction factor has been developed to further decrease calibration uncertainty when the goggles to be used have different spectral responsivities than the standard. Geometrical considerations to optimize the radiance measurement angle and the out-of-target blocking are also discussed to decrease the uncertainty in the radiance responsivity transfer.

  8. Optical Tweezer Assembly and Calibration

    Science.gov (United States)

    Collins, Timothy M.

    2004-01-01

    An Optical Tweezer, as the name implies, is a useful tool for precision manipulation of micro and nano scale objects. Using the principle of electromagnetic radiation pressure, an optical tweezer employs a tightly focused laser beam to trap and position objects of various shapes and sizes. These devices can trap micrometer and nanometer sized objects. An exciting possibility for optical tweezers is its future potential to manipulate and assemble micro and nano sized sensors. A typical optical tweezer makes use of the following components: laser, mirrors, lenses, a high quality microscope, stage, Charge Coupled Device (CCD) camera, TV monitor and Position Sensitive Detectors (PSDs). The laser wavelength employed is typically in the visible or infrared spectrum. The laser beam is directed via mirrors and lenses into the microscope. It is then tightly focused by a high magnification, high numerical aperture microscope objective into the sample slide, which is mounted on a translating stage. The sample slide contains a sealed, small volume of fluid that the objects are suspended in. The most common objects trapped by optical tweezers are dielectric spheres. When trapped, a sphere will literally snap into and center itself in the laser beam. The PSD s are mounted in such a way to receive the backscatter after the beam has passed through the trap. PSD s used with the Differential Interference Contrast (DIC) technique provide highly precise data. Most optical tweezers employ lasers with power levels ranging from 10 to 100 miliwatts. Typical forces exerted on trapped objects are in the pico-newton range. When PSDs are employed, object movement can be resolved on a nanometer scale in a time range of milliseconds. Such accuracy, however, can only by utilized by calibrating the optical tweezer. Fortunately, an optical tweezer can be modeled accurately as a simple spring. This allows Hook s Law to be used. My goal this summer at NASA Glenn Research Center is the assembly and

  9. Sistema Distribuido de Gran Escala

    Directory of Open Access Journals (Sweden)

    Fco. Javier Luna Rosas

    2006-01-01

    Full Text Available Este artículo propone una nueva forma de balancear la carga dinámicamente combinando un modelo Fuzzy-Logic en conjunto con el algoritmo distribuido Request for Bids (RB, el trabajo es centrado en el modelo Fuzzy-Logic con el propósito de mejorar el balanceo dinámico de carga en un sistema distribuido a gran escala. El modelo Fuzzy-Logic y RB fueron implementados en una arquitectura para balancear la carga bajo el estándar de CORBA y fueron evaluados contra otras estrategias que son bien conocidas en la literatura usando diferentes métricas de carga y mostramos como bajo ciertas condiciones nuestra estrategia obtiene mejores resultados.

  10. A Simple Accelerometer Calibrator

    Science.gov (United States)

    Salam, R. A.; Islamy, M. R. F.; Munir, M. M.; Latief, H.; Irsyam, M.; Khairurrijal

    2016-08-01

    High possibility of earthquake could lead to the high number of victims caused by it. It also can cause other hazards such as tsunami, landslide, etc. In that case it requires a system that can examine the earthquake occurrence. Some possible system to detect earthquake is by creating a vibration sensor system using accelerometer. However, the output of the system is usually put in the form of acceleration data. Therefore, a calibrator system for accelerometer to sense the vibration is needed. In this study, a simple accelerometer calibrator has been developed using 12 V DC motor, optocoupler, Liquid Crystal Display (LCD) and AVR 328 microcontroller as controller system. The system uses the Pulse Wave Modulation (PWM) form microcontroller to control the motor rotational speed as response to vibration frequency. The frequency of vibration was read by optocoupler and then those data was used as feedback to the system. The results show that the systems could control the rotational speed and the vibration frequencies in accordance with the defined PWM.

  11. Efeitos da radiação solar crônica prolongada sobre o sistema imunológico de pescadores profissionais em Recife (PE, Brasil Effects of long-term chronic exposure to sun radiation in immunological system of commercial fishermen in Recife, Brazil

    Directory of Open Access Journals (Sweden)

    Sarita Maria de Fátima Martins de Carvalho Bezerra

    2011-04-01

    Full Text Available FUNDAMENTOS: Existe um consenso de que a exposição à radiação ultravioleta determina alterações n o sistema imunológico da pele, o que permite que se avente a hipótese de que a exposição prolongada e crônica ao Sol pode representar uma das maiores agressões ambientais à saúde humana. Entre as várias ocupações que requerem, necessariamente, exposição prolongada e crônica ao Sol está a de pescador. No entanto, a experiência clínica dermatológica, amealhada ao longo de vários anos de exercício da Medicina, não parece confirmar essa hipótese. OBJETIVO: Avaliar efeitos clínicos, histológicos e imunológicos da exposição crônica e prolongada à radiação ultravioleta em pescadores. MÉTODOS: Em estudo prospectivo, transversal, observacional, foram caracterizadas lesões dermatológicas, marcadores imunológicos e alterações histológicas de pescadores e subpopulações de linfócitos comparadas a grupo-controle. Empregaram-se testes de Mann-Whitney, exato de Fisher, Wilcoxon em nível de 0,05. RESULTADOS: Houve diferenças entre os grupos exposto e protegido em elastose (p = 0,03, ectasia de vasos dérmicos (p = 0,012 e número de células nas camadas epidérmicas entre os cones (p = 0,029. Foram mais comuns em pescadores CD45RO, CD68+ e mastócitos na pele (p = 0,040, p BACKGROUND: Among the various occupations which necessarily require long-term and chronic sun exposure is that of a fisherman. However, clinical experience in dermatology earned over several years of medical practice does not seem to confirm this hypothesis. OBJECTIVE: To evaluate clinical, histological and immunological effects of long-term and chronic exposure to ultraviolet radiation in fishermen. METHODS: A prospective, cross-sectional and observational study characterized skin lesions, immunological markers and histological alterations in fishermen, as well as lymphocyte subpopulations compared to a control group. Mann-Whitney, Fisher's and

  12. Space environment's effect on MODIS calibration

    Science.gov (United States)

    Dodd, J. L.; Wenny, B. N.; Chiang, K.; Xiong, X.

    2010-09-01

    The MODerate resolution Imaging Spectroradiometer flies on board the Earth Observing System (EOS) satellites Terra and Aqua in a sun-synchronous orbit that crosses the equator at 10:30 AM and 2:30 PM, respectively, at a low earth orbit (LEO) altitude of 705 km. Terra was launched on December 18,1999 and Aqua was launched on May 4, 2002. As the MODIS instruments on board these satellites continue to operate beyond the design lifetime of six years, the cumulative effect of the space environment on MODIS and its calibration is of increasing importance. There are several aspects of the space environment that impact both the top of atmosphere (TOA) calibration and, therefore, the final science products of MODIS. The south Atlantic anomaly (SAA), spacecraft drag, extreme radiative and thermal environment, and the presence of orbital debris have the potential to significantly impact both MODIS and the spacecraft, either directly or indirectly, possibly resulting in data loss. Efforts from the Terra and Aqua Flight Operations Teams (FOT), the MODIS Instrument Operations Team (IOT), and the MODIS Characterization Support Team (MCST) prevent or minimize external impact on the TOA calibrated data. This paper discusses specific effects of the space environment on MODIS and how they are minimized.

  13. Sistemas de comunicaciones para vuelos no tripulados

    OpenAIRE

    Correa Vila, Alejandro

    2008-01-01

    La iniciativa ATLANTIDA engloba numerosos estudios de ingeniería con el objetivo de reformar el actual sistema de gestión del tráfico aéreo. Dentro de estos estudios se encuentran diversas investigaciones en el campo de las comunicaciones móviles. La gran variabilidad del entorno aeronáutico promueve el estudio de sistemas de comunicaciones móviles capaces de funcionar en este tipo de entorno. Este proyecto propone un sistema de comunicaciones WiMAX en un entorno aeronáutico con aviones no tr...

  14. El sistema acusatorio oral en Costa Rica

    OpenAIRE

    Hernández Barrantes, Jessica María; Rodríguez Montoya, Carmen María; Tenorio Jara

    2014-01-01

    El 1.° de enero de 1998 entra en vigencia el nuevo Código Procesal Penal, con lo cual se experimenta una de las reformas más importantes en materia de Administración de Justicia Penal, que implica el paso de un Sistema Procesal Inquisitivo a un Sistema Acusatorio que procura la adversarialidad entre partes. El antiguo Sistema Penal Inquisitivo se caracterizaba en que las funciones de investigar y juzgar se ejercían por el Juez de instrucción, el proceso era escrito y las dil...

  15. Sistemas de salvaguardia en reactores EPR

    OpenAIRE

    2015-01-01

    En este documento se describe brevemente el funcionamiento de los diversos sistemas de una planta nuclear operada con un reactor de tipo PWR. Más concretamente, el proyecto se centra en una descripción exhaustiva de los sistemas de salvaguardia y seguridad que regulan el funcionamiento de un reactor de tipo EPR, así como la central nuclear que contiene a dicho reactor. El proceso ha consistido en clasificar y resumir los distintos sistemas que operan en dicha planta, estudiando sus caracterís...

  16. Principales sistemas osmóticos orales

    OpenAIRE

    José Eduardo Hernández Torres; Luz María Melgoza Contreras

    2014-01-01

    Los sistemas de liberación convencionales tienen poco control sobre la liberación del fármaco, lo que resulta en concentraciones plasmáticas variables. Como consecuencia, se han desarrollado sistemas de liberación controlada, como los sistemas osmóticos que han demostrado ser independientes de las condiciones psiológicas del cuerpo (pH, alimento y movimientos peristálticos). La liberación del fármaco puede controlarse conociendo de antemano las propiedades psicoquímicas del fármaco y la forma...

  17. Sistemas de conciliación financiera

    OpenAIRE

    Cerro Campón, Ana

    2011-01-01

    Los sistemas de conciliaciones financieras, son sistemas que se basan en la carga de datos. Estos datos son extraídos previamente desde las aplicaciones propias de los movimientos bancarios. Esta información bancaria esta constituida en su mayoría por información sobre precios de distintos mercados. La finalidad de los sistemas de conciliación financiera es comprobar que todas las aplicaciones están alineadas, y que las operaciones realizadas con estos precios no se desvirtualizan de un siste...

  18. Elementos del sistema electoral del Congreso Mexicano

    OpenAIRE

    Aldo Medina García; Irina Cervantes Bravo

    2013-01-01

    El presente artículo es un estudio de los componentes del sistema electoral, diseñado por el legislador mexicano para integrar al parlamento federal. Estudio desarrollado a sabiendas de la importancia que reviste el sistema electoral como un medio que permite a los ciudadanos convertir su voto expresado en las urnas en escaños a favor de determinado candidato o partido. En dicho análisis tomamos en cuenta la evolución constitucional del sistema electoral mexicano, la participación de las fuer...

  19. Gestor de recursos sobre sistemas virtualizados

    OpenAIRE

    Gavilán García, Jesús Ruben

    2011-01-01

    Creacion, diseño e implementación de una nube (cloud) basado en un clúster de servidores con sistema de ficheros distribuido en red y virtualización de sistemas operativos que mejora la utilización de los recursos disponibles. Esta nueva arquitectura ofrece una nube privada que simplifica la gestión de los servicios y aporta una disminución del coste de mantenimiento, ademas de añadir flexibilidad, dinamismo y escalabilidad al sistema. Las tecnologías con las que se trabaja son GNU/Linux, Xen...

  20. Comparative calibration of IP scanning equipment

    Science.gov (United States)

    Ingenito, F.; Andreoli, P.; Batani, D.; Boutoux, G.; Cipriani, M.; Consoli, F.; Cristofari, G.; Curcio, A.; De Angelis, R.; Di Giorgio, G.; Ducret, J.; Forestier-Colleoni, P.; Hulin, S.; Jakubowska, K.; Rabhi, N.

    2016-05-01

    Imaging Plates (IP) are diagnostic devices which contain a photostimulable phosphor layer that stores the incident radiation dose as a latent image. The image is read with a scanner which stimulates the decay of electrons, previously excited by the incident radiation, by exposition to a laser beam. This results in emitted light, which is detected by photomultiplier tubes; so the latent image is reconstructed. IPs have the interesting feature that can be reused many times, after erasing stored information. Algorithms to convert signals stored in the detector to Photostimulated luminescence (PSL) counts depend on the scanner and are not available on every model. A comparative cross-calibration of the IP scanner Dürr CR35 BIO, used in ABC laboratory, was performed, using the Fujifilm FLA 7000 scanner as a reference, to find the equivalence between grey-scale values given by the Dürr scanner to PSL counts. Using an IP and a 55Fe β-source, we produced pairs of samples with the same exposition times, which were analysed by both scanners, placing particular attention to fading times of the image stored on IPs. Data analysis led us to the determine a conversion formula which can be used to compare data of experiments obtained in different laboratories and to use IP calibrations available, till now, only for Fujifilm scanners.

  1. Electro-optical equivalent calibration technology for high-energy laser energy meters.

    Science.gov (United States)

    Wei, Ji Feng; Chang, Yan; Sun, Li Qun; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei

    2016-04-01

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  2. Electro-optical equivalent calibration technology for high-energy laser energy meters

    Science.gov (United States)

    Wei, Ji Feng; Chang, Yan; Sun, Li Qun; Zhang, Kai; Hu, Xiao Yang; Zhang, Wei

    2016-04-01

    Electro-optical equivalent calibration with high calibration power and high equivalence is particularly well-suited to the calibration of high-energy laser energy meters. A large amount of energy is reserved during this process, however, which continues to radiate after power-off. This study measured the radiation efficiency of a halogen tungsten lamp during power-on and after power-off in order to calculate the total energy irradiated by a lamp until the high-energy laser energy meter reaches thermal equilibrium. A calibration system was designed based on the measurement results, and the calibration equivalence of the system was analyzed in detail. Results show that measurement precision is significantly affected by the absorption factor of the absorption chamber and by heat loss in the energy meter. Calibration precision is successfully improved by enhancing the equivalent power and reducing power-on time. The electro-optical equivalent calibration system, measurement uncertainty of which was evaluated as 2.4% (k = 2), was used to calibrate a graphite-cone-absorption-cavity absolute energy meter, yielding a calibration coefficient of 1.009 and measurement uncertainty of 3.5% (k = 2). A water-absorption-type high-energy laser energy meter with measurement uncertainty of 4.8% (k = 2) was considered the reference standard, and compared to the energy meter calibrated in this study, yielded a correction factor of 0.995 (standard deviation of 1.4%).

  3. Internal Water Vapor Photoacoustic Calibration

    Science.gov (United States)

    Pilgrim, Jeffrey S.

    2009-01-01

    Water vapor absorption is ubiquitous in the infrared wavelength range where photoacoustic trace gas detectors operate. This technique allows for discontinuous wavelength tuning by temperature-jumping a laser diode from one range to another within a time span suitable for photoacoustic calibration. The use of an internal calibration eliminates the need for external calibrated reference gases. Commercial applications include an improvement of photoacoustic spectrometers in all fields of use.

  4. Bilateral comparison 2012 between calibration laboratories dosimetry spaniards for qualities ISO: S-Cs and S-Co; Comparacion bilateral 2012 entre laboratorios de calibracion dosimetrica espanolaes para las calidades ISO: S-Cs y S-Co

    Energy Technology Data Exchange (ETDEWEB)

    Cornejo Diaz, N. A.; Ginjaume Egido, M.; Roig Costa, M.; Amores Medina, M.; Toll Escobedo, A.; Guantes Diez, E.

    2013-07-01

    This paper describes the Protocol and the results of the comparison bilateral organized during 2012, between two Spanish calibration laboratories. The main objective of the comparison was to contribute to verification and documentation of the consistency of calibration services offered at national level, with regard to the metrological traceability of calibrations and dose levels of protection assignments radiation to gamma radiation. (Author)

  5. RX130 Robot Calibration

    Science.gov (United States)

    Fugal, Mario

    2012-10-01

    In order to create precision magnets for an experiment at Oak Ridge National Laboratory, a new reverse engineering method has been proposed that uses the magnetic scalar potential to solve for the currents necessary to produce the desired field. To make the magnet it is proposed to use a copper coated G10 form, upon which a drill, mounted on a robotic arm, will carve wires. The accuracy required in the manufacturing of the wires exceeds nominal robot capabilities. However, due to the rigidity as well as the precision servo motor and harmonic gear drivers, there are robots capable of meeting this requirement with proper calibration. Improving the accuracy of an RX130 to be within 35 microns (the accuracy necessary of the wires) is the goal of this project. Using feedback from a displacement sensor, or camera and inverse kinematics it is possible to achieve this accuracy.

  6. SURF Model Calibration Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-10

    SURF and SURFplus are high explosive reactive burn models for shock initiation and propagation of detonation waves. They are engineering models motivated by the ignition & growth concept of high spots and for SURFplus a second slow reaction for the energy release from carbon clustering. A key feature of the SURF model is that there is a partial decoupling between model parameters and detonation properties. This enables reduced sets of independent parameters to be calibrated sequentially for the initiation and propagation regimes. Here we focus on a methodology for tting the initiation parameters to Pop plot data based on 1-D simulations to compute a numerical Pop plot. In addition, the strategy for tting the remaining parameters for the propagation regime and failure diameter is discussed.

  7. Radiological Calibration and Standards Facility

    Data.gov (United States)

    Federal Laboratory Consortium — PNNL maintains a state-of-the-art Radiological Calibration and Standards Laboratory on the Hanford Site at Richland, Washington. Laboratory staff provide expertise...

  8. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Kristensen, L.; Jensen, G.; Hansen, A.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statisticalsignificance of the calibration expressions....... It is concluded that the method has the advantage that many anemometers can be calibrated accurately with a minimum of work and cost. The obvious disadvantage is that the calibration of a set of anemometersmay take more than one month in order to have wind speeds covering a sufficiently large magnitude range...

  9. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya; Calibracion y estudio de las capacidades de medida de los equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigilancia radiologia ambiental de la Generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-10-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  10. Calibration of Nanopositioning Stages

    Directory of Open Access Journals (Sweden)

    Ning Tan

    2015-12-01

    Full Text Available Accuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatability are not well known and difficult to guarantee, which induces many drawbacks for many applications. For example, in the mechanical characterisation of biological samples, it is difficult to perform several cycles in a repeatable way so as not to induce negative influences on the study. It also prevents one from controlling accurately a tool with respect to a sample without adding additional sensors for closed loop control. This paper aims at quantifying the positioning repeatability and accuracy based on the ISO 9283:1998 standard, and analyzing factors influencing positioning accuracy onto a case study of 1-DoF (Degree-of-Freedom nanopositioning stage. The influence of thermal drift is notably quantified. Performances improvement of the nanopositioning stage are then investigated through robot calibration (i.e., open-loop approach. Two models (static and adaptive models are proposed to compensate for both geometric errors and thermal drift. Validation experiments are conducted over a long period (several days showing that the accuracy of the stage is improved from typical micrometer range to 400 nm using the static model and even down to 100 nm using the adaptive model. In addition, we extend the 1-DoF calibration to multi-DoF with a case study of a 2-DoF nanopositioning robot. Results demonstrate that the model efficiently improved the 2D accuracy from 1400 nm to 200 nm.

  11. Absolute Radiometric Calibration of KOMPSAT-3A

    Science.gov (United States)

    Ahn, H. Y.; Shin, D. Y.; Kim, J. S.; Seo, D. C.; Choi, C. U.

    2016-06-01

    This paper presents a vicarious radiometric calibration of the Korea Multi-Purpose Satellite-3A (KOMPSAT-3A) performed by the Korea Aerospace Research Institute (KARI) and the Pukyong National University Remote Sensing Group (PKNU RSG) in 2015.The primary stages of this study are summarized as follows: (1) A field campaign to determine radiometric calibrated target fields was undertaken in Mongolia and South Korea. Surface reflectance data obtained in the campaign were input to a radiative transfer code that predicted at-sensor radiance. Through this process, equations and parameters were derived for the KOMPSAT-3A sensor to enable the conversion of calibrated DN to physical units, such as at-sensor radiance or TOA reflectance. (2) To validate the absolute calibration coefficients for the KOMPSAT-3A sensor, we performed a radiometric validation with a comparison of KOMPSAT-3A and Landsat-8 TOA reflectance using one of the six PICS (Libya 4). Correlations between top-of-atmosphere (TOA) radiances and the spectral band responses of the KOMPSAT-3A sensors at the Zuunmod, Mongolia and Goheung, South Korea sites were significant for multispectral bands. The average difference in TOA reflectance between KOMPSAT-3A and Landsat-8 image over the Libya 4, Libya site in the red-green-blue (RGB) region was under 3%, whereas in the NIR band, the TOA reflectance of KOMPSAT-3A was lower than the that of Landsat-8 due to the difference in the band passes of two sensors. The KOMPSAT-3Aensor includes a band pass near 940 nm that can be strongly absorbed by water vapor and therefore displayed low reflectance. Toovercome this, we need to undertake a detailed analysis using rescale methods, such as the spectral bandwidth adjustment factor.

  12. Research on the calibration of ultraviolet energy meters

    Science.gov (United States)

    Lin, Fangsheng; Yin, Dejin; Li, Tiecheng; Lai, Lei; Xia, Ming

    2016-10-01

    Ultraviolet (UV) radiation is a kind of non-lighting radiation with the wavelength range from 100nm to 400nm. Ultraviolet irradiance meters are now widely used in many areas. However, as the development of science and technology, especially in the field of light-curing industry, there are more and more UV energy meters or UV-integrators need to be measured. Because the structure, wavelength band and measured power intensity of UV energy meters are different from traditional UV irradiance meters, it is important for us to take research on the calibration. With reference to JJG879-2002, we SIMT have independently developed the UV energy calibration device and the standard of operation and experimental methods for UV energy calibration in detail. In the calibration process of UV energy meter, many influencing factors will affect the final results, including different UVA-band UV light sources, different spectral response for different brands of UV energy meters, instability and no uniformity of UV light source and temperature. Therefore we need to take all of these factors into consideration to improve accuracy in UV energy calibration.

  13. GPS: El sistema de posicionamiento global

    National Research Council Canada - National Science Library

    Juan Gilberto Serpas; Manuel Ramírez N; Franklin de Obaldía

    2016-01-01

    El Sistema de Posicionamiento Global (GPS, por sus siglas en inglés) se ha convertido, en la actualidad, en una herramienta invaluable para el posicionamiento de puntos sobre la superficie terrestre...

  14. Sistemas basados en conocimiento usando Prolog

    Directory of Open Access Journals (Sweden)

    Zenaida García Valdivia

    2011-10-01

    Full Text Available Se exponen algunos de los resultados alcanzados en la Universidad Central "Marta Abreu" de Las Villas en cuanto al uso de un lenguaje de Programación Lógica (Prolog en la elaboración de Sistemas Basados en Conocimiento para diferentes áreas del saber como son la medicina, soldadura, educación, sistemas eléctricos de potencia, entre otros. Todos los sistemas elaborados utilizan el paradigma de la programación lógica para la representación del conocimiento de los expertos en los temas en cuestión y además hacen uso de entornos agradables a los usuarios a través interfaces visuales elaboradas en ambientes de programación para súper lenguajes ó utilizan un conjunto de herramientas para la elaboración de sistemas sobre la Web

  15. Calibration of dosimeters at 80-120 keV electron irradiation

    DEFF Research Database (Denmark)

    Miller, A.; Helt-Hansen, J.

    We describe calorimeters for dose measurement at low-energy electron accelerator energies (80–120 keV). Three calorimeters with different characteristics were designed and their dose response and measurement uncertainties were characterized. The heatedair between the electron beam exit window...... to calibrate thin-film dosimeters (Risø B3 and alanine films) by irradiation at the 80–120 keV electron accelerators. This calibration was compared to a 10MeV calibration, and we show that the radiation response of the dosimeter materials (the radiation chemical yield) is constant at these irradiation energies...

  16. El sistema presidencial mexicano. Actualidad y perspectivas

    OpenAIRE

    Diego VALADÉS

    2011-01-01

    Este ensayo presenta un análisis del sistema presidencial mexicano desde una perspectiva constitucional. Se hace especial referencia a la concentración del poder presidencial y a las relaciones entre el Congreso y el gobierno. Asimismo, se incluyen consideraciones comparativas entre los sistemas presidenciales estadounidense y mexicano. El concepto vertical del poder en México no ha sido modificado de manera significativa desde su versión original de 1917, por lo que se hacen ostensibles las ...

  17. Gerencia de sistemas conductuales y cambio organizacional

    Directory of Open Access Journals (Sweden)

    Guillermo E. Yáber

    1998-01-01

    Full Text Available La gerencia de sistemas conductuales es una tecnología basada en un enfoque científico para el análisis del comportamiento en sistemas humanos. Esta tecnología ayuda a las organizaciones a definir y lograr sus metas. Consiste en el análisis, especificación, diseño, implementación, evaluación y reciclaje de sistemas de motivación humana que optimizan el desempeño y desarrollo a nivel del sistema total, departamental e individual de la organización. Utiliza tres modelos: El diseño de sistemas dirigidos hacia la meta, el análisis de «Tres Contingencias» y la gerencia del desempeño para el cambio cultural. Este artículo incluye la descripción del marco teórico y metodológico de la gerencia de sistemas conductuales y su aplicación en las áreas de servicios y producción.

  18. Radiation Protection

    Science.gov (United States)

    ... EPA United States Environmental Protection Agency Search Search Radiation Protection Share Facebook Twitter Google+ Pinterest Contact Us Radiation Protection Document Library View and download EPA radiation ...

  19. The NIF x-ray spectrometer calibration campaign at Omega.

    Science.gov (United States)

    Pérez, F; Kemp, G E; Regan, S P; Barrios, M A; Pino, J; Scott, H; Ayers, S; Chen, H; Emig, J; Colvin, J D; Bedzyk, M; Shoup, M J; Agliata, A; Yaakobi, B; Marshall, F J; Hamilton, R A; Jaquez, J; Farrell, M; Nikroo, A; Fournier, K B

    2014-11-01

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the Omega laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2-18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  20. The NIF x-ray spectrometer calibration campaign at Omega

    Energy Technology Data Exchange (ETDEWEB)

    Pérez, F.; Kemp, G. E.; Barrios, M. A.; Pino, J.; Scott, H.; Ayers, S.; Chen, H.; Emig, J.; Colvin, J. D.; Fournier, K. B., E-mail: fournier2@llnl.gov [Lawrence Livermore National Laboratory, P. O. Box 808, Livermore, California 94551 (United States); Regan, S. P.; Bedzyk, M.; Shoup, M. J.; Agliata, A.; Yaakobi, B.; Marshall, F. J.; Hamilton, R. A. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Jaquez, J.; Farrell, M.; Nikroo, A. [General Atomics, P.O. Box 85608, San Diego, California 92186 (United States)

    2014-11-15

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the OMEGA laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2–18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  1. Tectonic calibrations in molecular dating

    Institute of Scientific and Technical Information of China (English)

    Ullasa KODANDARAMAIAH

    2011-01-01

    Molecular dating techniques require the use of calibrations, which are usually fossil or geological vicariance-based.Fossil calibrations have been criticised because they result only in minimum age estimates. Based on a historical biogeographic perspective, Ⅰ suggest that vicariance-based calibrations are more dangerous. Almost all analytical methods in historical biogeography are strongly biased towards inferring vicariance, hence vicariance identified through such methods is unreliable. Other studies, especially of groups found on Gondwanan fragments, have simply assumed vicariance. Although it was previously believed that vicariance was the predominant mode of speciation, mounting evidence now indicates that speciation by dispersal is common, dominating vicariance in several groups. Moreover, the possibility of speciation having occurred before the said geological event cannot be precluded. Thus, geological calibrations can under- or overestimate times, whereas fossil calibrations always result in minimum estimates. Another major drawback of vicariant calibrations is the problem of circular reasoning when the resulting estimates are used to infer ages of biogeographic events. Ⅰ argue that fossil-based dating is a superior alternative to vicariance, primarily because the strongest assumption in the latter, that speciation was caused by the said geological process, is more often than not the most tenuous. When authors prefer to use a combination of fossil and vicariant calibrations, one suggestion is to report results both with and without inclusion of the geological constraints. Relying solely on vicariant calibrations should be strictly avoided.

  2. UVIS G280 Wavelength Calibration

    Science.gov (United States)

    Bushouse, Howard

    2009-07-01

    Wavelength calibration of the UVIS G280 grism will be established using observations of the Wolf Rayet star WR14. Accompanying direct exposures will provide wavelength zeropoints for dispersed exposures. The calibrations will be obtained at the central position of each CCD chip and at the center of the UVIS field. No additional field-dependent variations will be obtained.

  3. Cogeneration Systems; Sistemas de Cogeneracion

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez M, Manuel F; Huante P, Liborio; Romo M, Cesar A [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2006-07-01

    The present article deals on relevant aspects on the subject of cogeneration within the Mexican territorial limits. In the first place it is presented the role of Mexico in terms of its cogeneration potential, the type of service that has obtained from this predominant modality of cogeneration for self-supplying, the most propitious sectors to develop it, its legislations on the matter, the projects made for the implementation of cogeneration plants, as well as the existing cogeneration schemes for its respective optimization proposals. Without leaving out the analysis on the different types of evaluation on the efficiency of cogeneration systems and the aspects to consider for the election of a generation cycle. [Spanish] El presente articulo trata sobre aspectos relevantes en materia de cogeneracion dentro de los limites territoriales de la nacion mexicana. Se muestra en primer lugar el papel de Mexico en terminos de su potencial de cogeneracion, el tipo de servicio que ha obtenido de esta predominantemente (modalidad de cogeneracion para autoabastecimiento), los sectores mas propicios para desarrollarla, sus legislaciones al respecto, los proyectos realizados para la implementacion de plantas de cogeneracion, asi como los esquemas de cogeneracion existentes con sus respectivas propuestas de optimizacion. Sin dejar de lado el analisis sobre los distintos tipos de evaluacion de la eficiencia de sistemas de cogeneracion y los aspectos a considerar para la eleccion de un ciclo de generacion.

  4. Cobalt source calibration

    Energy Technology Data Exchange (ETDEWEB)

    Rizvi, H.M.

    1999-12-03

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10{sup 5} rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10{sup 5} rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10{sup 5} rad/h to 1.073 x 10{sup 5} rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10{sup 6} to 9.27 x 10{sup 5}. This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10{sup 7} rad/h. During irradiation of the Fricke dosimeter solution the Fe{sup 2+} ions ionize to Fe{sup 3+}. When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate.

  5. Pre-flight calibration of LYRA, the solar VUV radiometer on board PROBA2

    Science.gov (United States)

    Benmoussa, A.; Dammasch, I. E.; Hochedez, J.-F.; Schühle, U.; Koller, S.; Stockman, Y.; Scholze, F.; Richter, M.; Kroth, U.; Laubis, C.; Dominique, M.; Kretzschmar, M.; Mekaoui, S.; Gissot, S.; Theissen, A.; Giordanengo, B.; Bolsee, D.; Hermans, C.; Gillotay, D.; Defise, J.-M.; Schmutz, W.

    2009-12-01

    Aims. LYRA, the Large Yield Radiometer, is a vacuum ultraviolet (VUV) solar radiometer, planned to be launched in November 2009 on the European Space Agency PROBA2, the Project for On-Board Autonomy spacecraft. Methods: The instrument was radiometrically calibrated in the radiometry laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the Berlin Electron Storage ring for SYnchroton radiation (BESSY II). The calibration was done using monochromatized synchrotron radiation at PTB's VUV and soft X-ray radiometry beamlines using reference detectors calibrated with the help of an electrical substitution radiometer as the primary detector standard. Results: A total relative uncertainty of the radiometric calibration of the LYRA instrument between 1% and 11% was achieved. LYRA will provide irradiance data of the Sun in four UV passbands and with high temporal resolution down to 10 ms. The present state of the LYRA pre-flight calibration is presented as well as the expected instrument performance.

  6. Automated calibration of multistatic arrays

    Energy Technology Data Exchange (ETDEWEB)

    Henderer, Bruce

    2017-03-14

    A method is disclosed for calibrating a multistatic array having a plurality of transmitter and receiver pairs spaced from one another along a predetermined path and relative to a plurality of bin locations, and further being spaced at a fixed distance from a stationary calibration implement. A clock reference pulse may be generated, and each of the transmitters and receivers of each said transmitter/receiver pair turned on at a monotonically increasing time delay interval relative to the clock reference pulse. Ones of the transmitters and receivers may be used such that a previously calibrated transmitter or receiver of a given one of the transmitter/receiver pairs is paired with a subsequently un-calibrated one of the transmitters or receivers of an immediately subsequently positioned transmitter/receiver pair, to calibrate the transmitter or receiver of the immediately subsequent transmitter/receiver pair.

  7. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  8. TIME CALIBRATED OSCILLOSCOPE SWEEP CIRCUIT

    Science.gov (United States)

    Smith, V.L.; Carstensen, H.K.

    1959-11-24

    An improved time calibrated sweep circuit is presented, which extends the range of usefulness of conventional oscilloscopes as utilized for time calibrated display applications in accordance with U. S. Patent No. 2,832,002. Principal novelty resides in the provision of a pair of separate signal paths, each of which is phase and amplitude adjustable, to connect a high-frequency calibration oscillator to the output of a sawtooth generator also connected to the respective horizontal deflection plates of an oscilloscope cathode ray tube. The amplitude and phase of the calibration oscillator signals in the two signal paths are adjusted to balance out feedthrough currents capacitively coupled at high frequencies of the calibration oscillator from each horizontal deflection plate to the vertical plates of the cathode ray tube.

  9. Antenna Calibration and Measurement Equipment

    Science.gov (United States)

    Rochblatt, David J.; Cortes, Manuel Vazquez

    2012-01-01

    A document describes the Antenna Calibration & Measurement Equipment (ACME) system that will provide the Deep Space Network (DSN) with instrumentation enabling a trained RF engineer at each complex to perform antenna calibration measurements and to generate antenna calibration data. This data includes continuous-scan auto-bore-based data acquisition with all-sky data gathering in support of 4th order pointing model generation requirements. Other data includes antenna subreflector focus, system noise temperature and tipping curves, antenna efficiency, reports system linearity, and instrument calibration. The ACME system design is based on the on-the-fly (OTF) mapping technique and architecture. ACME has contributed to the improved RF performance of the DSN by approximately a factor of two. It improved the pointing performances of the DSN antennas and productivity of its personnel and calibration engineers.

  10. Calibration of the CMS electromagnetic calorimeter with LHC collision data

    Science.gov (United States)

    Obertino, M. M.; CMS Collaboration

    2013-08-01

    The CMS ECAL is a high resolution electromagnetic calorimeter which relies upon precision calibration in order to achieve and maintain its design performance. Variations in light collected from the lead tungstate crystals, due to intrinsic differences in crystals/photodetectors, as well as variations with time due to radiation damage for example, need to be taken into account. Sophisticated and effective methods of inter-crystal and absolute calibration have been devised, using collision data from the 2011 LHC run and a dedicated light injection system. For inter-calibration, low mass particle (π0 and η) decays to two photons are exploited, as well as the azimuthal symmetry of the average energy deposition at a given pseudorapidity. The light injection system monitors the channel response in real-time and enables the re-calibration of the measured energies over time. This is cross-checked by the comparison of E/p measurements of electrons from W decays (where the momentum is measured in the CMS tracker) with/without these re-calibrations applied. Absolute calibration has been performed using Z decays into electron-positron pairs.

  11. COMPARISON METHODOLOGIES FOR CALIBRATION OF Hp(10) PERSONAL DOSEMETERS USING ISO 4037 AND ISO 29661 STANDARDS.

    Science.gov (United States)

    Cardoso, J; Santos, L; Carvalhal, G; Oliveira, C

    2016-09-01

    The calibration of electronic personal dosemeters at the Portuguese ionizing radiation metrology laboratory uses the standard IEC 61526 for calibration methodology. This standard describes the irradiation geometry for testing and indicates that the standard ISO 4037-1, 2, 3 and 4 should be used. The ISO 4037 establishes that the reference point of test is a point in the radiation monitor, known or established, and the calibration phantom should be placed on its back in order to simulate the trunk body. Recently, ISO published another standard, the ISO 29661, that changes the reference point from the radiation monitor to the front face of the calibration phantom. The aim of this work is to present the result of the comparison of these two methodologies on personal dosemeters from five different manufacturers. The work shows differences in the Hp(10) response up to 4% resulting from the two different reference point concepts.

  12. Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

    Science.gov (United States)

    Ng, Daniel

    2001-01-01

    There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

  13. A calibrated Franklin chimes

    Science.gov (United States)

    Gonta, Igor; Williams, Earle

    1994-05-01

    Benjamin Franklin devised a simple yet intriguing device to measure electrification in the atmosphere during conditions of foul weather. He constructed a system of bells, one of which was attached to a conductor that was suspended vertically above his house. The device is illustrated in a well-known painting of Franklin (Cohen, 1985). The elevated conductor acquired a potential due to the electric field in the atmosphere and caused a brass ball to oscillate between two bells. The purpose of this study is to extend Franklin's idea by constructing a set of 'chimes' which will operate both in fair and in foul weather conditions. In addition, a mathematical relationship will be established between the frequency of oscillation of a metallic sphere in a simplified geometry and the potential on one plate due to the electrification of the atmosphere. Thus it will be possible to calibrate the 'Franklin Chimes' and to obtain a nearly instantaneous measurement of the potential of the elevated conductor in both fair and foul weather conditions.

  14. [VMTBB-Based Spectral Radiometric Calibration of NIR Fiber Coupled Spectrometer].

    Science.gov (United States)

    Zheng, Feng; Liu, Li-ying; Liu, Xiao-xi; Li, Ye; Shi, Xiao-guang; Zhang, Guo-yu; Huan, Ke-wei

    2015-09-01

    The medium temperature black body (MTBB) is conventional high precision equipment used as spectral radiometric scale in infrared spectral region. However, in near-infrared (NIR) spectral region, there are few papers about spectral radiometric calibration by using MTBB, that is because NIR spectral region is the borderland of its effective spectral region. The main research of this paper is spectral radiometric calibration method by using MTBB in NIR spectral region. Accordingly, this paper is devoted mostly to a discussion of how the calibration precision could be affected by selecting different structural parameters of calibration model. The purpose of this paper is to present the results of research and provide technical reference for improving the traceability in NIR spectral radiometric calibration. In this paper, a NIR fiber coupled spectrometer, whose wavelength range covers from 950 to 1700 nm, has been calibrated by a MTBB with adjustable temperature range from 50 to 1050 °C. Concentrating on calibration process, two key points have been discussed. For one thing, the geometric factors of radiation transfer model of the calibration systems have been compared between traditional structure and fiber direct-coupled structure. Because the fiber direct-coupled model is simple and effective, it has been selected instead of traditional model based on the radiation transfer between two coaxial discs. So, it is an advantaged radiation transfer model for radiometric calibration of fiber coupled spectrometer. For another thing, the relation between calibration accuracy and structural parameters of calibration model has been analyzed intensively. The root cause is scale feature of attribute of calibration data itself, which is the nonlinear structure in scales of spectral data. So, the high precision calibration needs nonlinear calibration model, and the uniform sampling for scale feature is also very important. Selecting sample is an inevitable problem when the

  15. Radiation Therapy

    Science.gov (United States)

    ... the area is stitched shut. Another treatment, called proton-beam radiation therapy , focuses the radiation on the ... after radiation treatment ends. Sore mouth and tooth decay. If you received radiation therapy to the head ...

  16. Radiation sickness

    Science.gov (United States)

    ... radiation. There are two basic types of radiation: ionizing and nonionizing. Nonionizing radiation comes in the form of light, radio waves, microwaves and radar. This kind of radiation usually ...

  17. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  18. Study on routines and procedures of calibration of clinical dosemeter on gamma radiation beams at the IPEN-CNEN/SP, Brazil; Estudo das rotinas e procedimentos de calibracao de dosimetros clinicos em feixes de radiacao gama no IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Damatto, Willian B.; Potiens, Maria da Penha A.; Santos, Gelson P.; Vivolo, Vitor, E-mail: wbdamatto@ipen.b, E-mail: mppalbu@ipen.b, E-mail: gpsantos@ipen.b, E-mail: vivolo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    The calibration consists in the comparison of the equipment to be calibrated with other equipment already calibrated by another standard, which means the equipment that will accomplish shall be considered secondary or tertiary, depending on the calibration that will be accomplished. As the clinical dosemeters are used for quality control services in the hospitals, these dosemeters need a reliable measurement precision. Therefore, this work intends to demonstrate the importance of the clinical dosemeter and the calibration, requiring special care face to all clinical set

  19. Radiation dosimetry.

    OpenAIRE

    Cameron, J

    1991-01-01

    This article summarizes the basic facts about the measurement of ionizing radiation, usually referred to as radiation dosimetry. The article defines the common radiation quantities and units; gives typical levels of natural radiation and medical exposures; and describes the most important biological effects of radiation and the methods used to measure radiation. Finally, a proposal is made for a new radiation risk unit to make radiation risks more understandable to nonspecialists.

  20. Site characterization for calibration of radiometric sensors using vicarious method

    Science.gov (United States)

    Parihar, Shailesh; Rathore, L. S.; Mohapatra, M.; Sharma, A. K.; Mitra, A. K.; Bhatla, R.; Singh, R. S.; Desai, Yogdeep; Srivastava, Shailendra S.

    2016-05-01

    Radiometric performances of earth observation satellite/sensors vary from ground pre-launch calibration campaign to post launch period extended to lifetime of the satellite due to launching vibrations. Therefore calibration is carried out worldwide through various methods throughout satellite lifetime. In India Indian Space Research Organization (ISRO) calibrates the sensor of Resourcesat-2 satellite by vicarious method. One of these vicarious calibration methods is the reflectance-based approach that is applied in this study for radiometric calibration of sensors on-board Resouresat-2 satellite. The results of ground-based measurement of atmospheric conditions and surface reflectance are made at Bap, Rajasthan Calibration/Validation (Cal/Val) site. Cal/Val observations at site were carried out with hyper-spectral Spectroradiometer covering spectral range of 350nm- 2500nm for radiometric characterization of the site. The Sunphotometer/Ozonometer for measuring the atmospheric parameters has also been used. The calibrated radiance is converted to absolute at-sensor spectral reflectance and Top-Of-Atmosphere (TOA) radiance. TOA radiance was computed using radiative transfer model `Second simulation of the satellite signal in the solar spectrum' (6S), which can accurately simulate the problems introduced by the presence of the atmosphere along the path from Sun to target (surface) to Sensor. The methodology for band averaged reflectance retrieval and spectral reflectance fitting process are described. Then the spectral reflectance and atmospheric parameters are put into 6S code to predict TOA radiance which compare with Resourcesat-2 radiance. Spectral signature and its reflectance ratio indicate the uniformity of the site. Thus the study proves that the selected site is suitable for vicarious calibration of sensor of Resourcesat-2. Further the study demonstrates the procedure for similar exercise for site selection for Cal/Val analysis of other satellite over India

  1. Imaging calibration of thermoacoustic tomography distortion caused by microwave diffraction

    Science.gov (United States)

    Nie, Liming; Xing, Da

    2009-08-01

    A uniform energy field of microwave illumination on sample is assumed for microwave-induced thermoacoustic tomography. However, microwave transmitting out of the waveguide surface is nonuniform due to microwave diffraction, which would lead to uneven excitation of thermoacoustic pressure. Hence, the thermoacoustic images may be distorted especially at the edge of microwave radiation. A fast thermoacoustic tomography system at 6 GHz was developed for phantom study and in vivo animals imaging. The effects of microwave distribution inhomogeneity on nonuniform excitation of acoustic pressure were theoretically studied and a corresponding calibration algorithm for image distortion was also provided and experimentally verified. The distribution formulas of microwave field were derived using a Huygens diffraction principle model. Then a point microwave absorber moved under the microwave waveguide to measure the microwave field distribution. The measure data is in good agreement with the deduced result. Once the calibration map was obtained via the theoretical calculation, the TAT (thermoacoustic tomography) images could be calibrated by dividing the reconstructed image by the calibration map. Thermoacoustic images without and with calibration were reconstructed for comparison. According to the statistical results, after calibration the thermoacoustic contrast can be enhanced 2 times or more. Also it can be supposed that the farther the distance away from the illumination centre, the greater signal-noise-ratio (SNR) could be enhanced by the calibration. The results of experiment showed that this method could achieve even distribution of SNR and improve the reconstructed image quality. Therefore, this calibration method has potential application in solving the problem of imaging distortion especially at the edge of microwave illumination.

  2. SMAP RADAR Processing and Calibration

    Science.gov (United States)

    West, R. D.; Jaruwatanadilok, S.; Kwoun, O.; Chaubell, M. J.

    2013-12-01

    The Soil Moisture Active Passive (SMAP) mission uses L-band radar and radiometer measurements to estimate soil moisture with 4% volumetric accuracy at a resolution of 10 km, and freeze-thaw state at a resolution of 1-3 km. Model sensitivities translate the soil moisture accuracy to a radar backscatter accuracy of 1 dB at 3 km resolution and a brightness temperature accuracy of 1.3 K at 40 km resolution. This presentation will describe the level 1 radar processing and calibration challenges and the choices made so far for the algorithms and software implementation. To obtain the desired high spatial resolution the level 1 radar ground processor employs synthetic aperture radar (SAR) imaging techniques. Part of the challenge of the SMAP data processing comes from doing SAR imaging on a conically scanned system with rapidly varying squint angles. The radar echo energy will be divided into range/Doppler bins using time domain processing algorithms that can easily follow the varying squint angle. For SMAP, projected range resolution is about 250 meters, while azimuth resolution varies from 400 meters to 1.2 km. Radiometric calibration of the SMAP radar means measuring, characterizing, and where necessary correcting the gain and noise contributions from every part of the system from the antenna radiation pattern all the way to the ground processing algorithms. The SMAP antenna pattern will be computed using an accurate antenna model, and then validated post-launch using homogeneous external targets such as the Amazon rain forest to look for uncorrected gain variation. Noise subtraction is applied after image processing using measurements from a noise only channel. Variations of the internal electronics are tracked by a loopback measurement which will capture most of the time and temperature variations of the transmit power and receiver gain. Long-term variations of system performance due to component aging will be tracked and corrected using stable external reference

  3. Calibration of high-heat-flux sensors in a solar furnace

    Energy Technology Data Exchange (ETDEWEB)

    Ballestrin, J.; Rodriguez-Alonso, M.; Rodriguez, J.; Canadas, I. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Almeria (Spain); Barbero, F.J. [Almeria Univ., Dept. de Fisica (Spain); Langley, L.W.; Barnes, A. [Vatell Corporation, Christiansburg, VA (United States)

    2006-12-15

    The most common sensors used for the measurement of high solar irradiance are the Gardon gauges, which are usually calibrated using a black body at a certain temperature as the radiant source. This calibration procedure is assumed to produce a systematic error when solar irradiance measurements are taken using these sensors. This paper demonstrates a calorimetric method for calibrating these high-heat-flux gauges in a solar furnace. This procedure has enabled these sensors to be calibrated under concentrated solar radiation at higher irradiances under non-laboratory conditions in the CIEMAT solar furnace at the Plataforma Solar de Almeria. Working at higher irradiances has allowed the uncertainty in the calibration constant of these sensors to be reduced. This work experimentally confirms the predicted systematic errors committed when measuring high solar irradiances using Gardon sensors calibrated with a black body. (authors)

  4. Calibration of high-heat-flux sensors in a solar furnace

    Science.gov (United States)

    Ballestrín, J.; Rodríguez-Alonso, M.; Rodríguez, J.; Cañadas, I.; Barbero, F. J.; Langley, L. W.; Barnes, A.

    2006-12-01

    The most common sensors used for the measurement of high solar irradiance are the Gardon gauges, which are usually calibrated using a black body at a certain temperature as the radiant source. This calibration procedure is assumed to produce a systematic error when solar irradiance measurements are taken using these sensors. This paper demonstrates a calorimetric method for calibrating these high-heat-flux gauges in a solar furnace. This procedure has enabled these sensors to be calibrated under concentrated solar radiation at higher irradiances under non-laboratory conditions in the CIEMAT solar furnace at the Plataforma Solar de Almería. Working at higher irradiances has allowed the uncertainty in the calibration constant of these sensors to be reduced. This work experimentally confirms the predicted systematic errors committed when measuring high solar irradiances using Gardon sensors calibrated with a black body.

  5. Regulación neuroendocrina del sistema inmune

    OpenAIRE

    Caballero Hernández, Diana; Tamez Guerra, Reyes S.; RODRÍGUEZ PADILLA, CRISTINA; Tamez Guerra, Patricia; Weber, Richard J.; GÓMEZ FLORES, RICARDO

    2001-01-01

    El sistema inmune recibe señales del sistema nervioso central (cerebro) vía el sistema nervioso autónomo y el sistema endocrino. El sistema inmune, a su vez, envía información al cerebro vía citocinas. Este sistema de retroalimentación es vital para el funcionamiento adecuado del organismo en situaciones normales, y en aquellas en las que la homeostasis se ve perturbada, como en casos de estrés, consumo de drogas (terapéuticas o de abuso), enfermedades infecciosas y...

  6. Sistemas de control reseteado discretos : aplicaciones a control en red

    OpenAIRE

    Pérez Rubio, Félix

    2012-01-01

    Esta tesis presenta un estudio de los sistemas de control reseteados en tiempo discreto y su aplicación a los sistemas de control en red. Se da una formulación formal que es coherente con las formulaciones de sistemas de control reseteados continuos. Para ello se emplean elementos de sistemas impulsivos y sistemas conmutados. En este trabajo se aborda la estabilidad de los sistemas reseteados en tiempo discreto empleando técnicas de regularización temporal y también técnicas de anál...

  7. Calibrating System for Vacuum Gauges

    Institute of Scientific and Technical Information of China (English)

    MengJun; YangXiaotian; HaoBinggan; HouShengjun; HuZhenjun

    2003-01-01

    In order to measure the vacuum degree, a lot of vacuum gauges will be used in CSR vacuum system. We bought several types of vacuum gauges. We know that different typos of vacuum gauges or even one type of vacuum gauges have different measure results in same condition, so they must be calibrated. But it seems impossible for us to send so many gauges to the calibrating station outside because of the high price. So the best choice is to build a second class calibrating station for vacuum gauges by ourselves (Fig.l).

  8. Jet energy calibration in ATLAS

    CERN Document Server

    Schouten, Doug

    A correct energy calibration for jets is essential to the success of the ATLAS experi- ment. In this thesis I study a method for deriving an in situ jet energy calibration for the ATLAS detector. In particular, I show the applicability of the missing transverse energy projection fraction method. This method is shown to set the correct mean energy for jets. Pileup effects due to the high luminosities at ATLAS are also stud- ied. I study the correlations in lateral distributions of pileup energy, as well as the luminosity dependence of the in situ calibration metho

  9. Manufacture of Single 60Co Source Irradiation Facility and the Measurement of Reference Radiation Filed

    Institute of Scientific and Technical Information of China (English)

    GAO; Fei; WANG; Hong-yu; NI; Ning; ZHANG; Li; HOU; Jin-bing; SONG; Ming-zhe

    2012-01-01

    <正>Reference radiation filed produced by isotope source is necessary for calibration of radiation dose meter. 60Co single source radiation facility is an important method to produce reference radiation. Collimation design of the facility is good for characteristics of the field, but there are scattered photon influences however. Scattered radiation is mainly come from collimation, source shield, floor, walls and

  10. Modeling of germanium detector and its sourceless calibration

    Directory of Open Access Journals (Sweden)

    Steljić Milijana

    2008-01-01

    Full Text Available The paper describes the procedure of adapting a coaxial high-precision germanium detector to a device with numerical calibration. The procedure includes the determination of detector dimensions and establishing the corresponding model of the system. In order to achieve a successful calibration of the system without the usage of standard sources, Monte Carlo simulations were performed to determine its efficiency and pulse-height response function. A detailed Monte Carlo model was developed using the MCNP-5.0 code. The obtained results have indicated that this method represents a valuable tool for the quantitative uncertainty analysis of radiation spectrometers and gamma-ray detector calibration, thus minimizing the need for the deployment of radioactive sources.

  11. Calibration of the BABAR CsI (Tl) calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Marks, Joerg, E-mail: marks@physi.uni-heidelberg.d [Physikalisches Institut, Universitaet Heidelberg, Philosophenweg 12, D-69120 Heidelberg (Germany)

    2009-04-01

    After nine years of operation, the BABAR experiment at the e{sup +}e{sup -} B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

  12. Calibration of the BABAR CsI (Tl) calorimeter

    Science.gov (United States)

    Marks, Jörg; Calorimeter Group of BARBAR Collaboration

    2009-04-01

    After nine years of operation, the BABAR experiment at the e+e- B factory PEP-II (Standford Linear Accelerator Center) stopped data taking in April 2008. An important part of the experiment is the electromagnetic calorimeter which consists of 6580 CsI crystals doped with thallium and read out by Si-PIN photodiodes. The light yield of the CsI crystals is changing in time due to radiation exposure. In addition to the changing light yield, passive material in front of and between the crystals as well as signal thresholds during the reconstruction influence the reconstructed energies. This requires a time-dependent calibration of the calorimeter. The calibration issues are reviewed and the calibration results obtained from various data samples are presented.

  13. New instrument calibration facility for the DOE Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Wilkie, W.H.; Polz, E.J. [Westinghouse Savannah River Company, Aiken, SC (United States)

    1993-12-31

    A new laboratory facility is being designed, constructed, and equipped at the Savannah River Site (SRS) as a fiscal year 1992 line item project. This facility will provide space and equipment for test, evaluation, repair, maintenance, and calibration of radiation monitoring instrumentation. The project will replace an obsolete facility and will allow implementation of program upgrades necessary to meet ANSI N323 requirements and National Voluntary Laboratory Accreditation Program (NVLAP) criteria for accreditation of federally owned secondary calibration laboratories. An outline of the project is presented including description, scope, cost, management organization, chronology, and current status. Selected design criteria and their impacts on the project are discussed. The upgraded SRS calibration program is described, and important features of the new facility and equipment that will accommodate this program are listed. The floor plan for the facility is shown, and equipment summaries and functional descriptions for each area are provided.

  14. Sistemas territoriales de salud frente al sistema general de seguridad social en salud de Colombia

    Directory of Open Access Journals (Sweden)

    Jahir Alexander Gutiérrez Ossa

    2014-06-01

    Full Text Available Introducción: El artículo expone los elementos y fundamentos que podrían avalar la generación de sistemas de seguridad social en salud territorial, en complementación con el sistema general preexistente. Materiales y Métodos: La eclosión generalizada en los sistemas de salud, implica la revisión de los modelos propuestos de carácter central y territorial. El análisis económico institucional, permite analizar las condiciones que tienen los sistemas generales para impactar en los esquemas territoriales. Resultados: Es el momento preciso, para que el sistema general en Colombia responda efectivamente en la materia, y que tanto ello, podría dar cuenta de la capacidad sistémica del mismo en el escenario territorial. Discusión: Es importante, que las gobernaciones y municipios planteen el alcance de dicha iniciativa. El Sistema General de Seguridad Social en Salud en Colombia, gira en torno a modelos y no a la concepción de sistema de salud efectivamente. Conclusiones: La definición de sistema de salud está opacando la atención para definir lo que implica efectivamente la salud, independiente de cualquier sistema al que se pretenda apuntar al final. Palabras clave: Cobertura de Servicios Públicos de Salud, Evaluación en Salud, Sistemas Multiinstitucionales, Sistemas Nacionales de Salud, Políticas Públicas de Salud. (Fuente: DeCS BIREME. Cómo citar este artículo: Gutiérrez Ossa JA, Restrepo Avendaño RD. Sistemas territoriales de salud frente al sistema general de seguridad social en salud de Colombia. Rev Cuid. 2014; 5(1: 623-32.

  15. Coast guard STD calibration procedures

    National Research Council Canada - National Science Library

    Freeman, R.H; Krug, W.S

    1973-01-01

    This manual describes the procedures used by the Coast Guard Oceanographic UNIT (CGOU) to calibrate several Model 9040 STD systems, manufactured by Plessey Environmental Systems, currently in use within the Coast Guard...

  16. Astrid-2 EMMA Magnetic Calibration

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Risbo, Torben

    1998-01-01

    experiment built as a collaboration between the DTU, Department of Automation and the Department of Plasma Physics, The Alfvenlaboratory, Royal Institute of Technology (RIT), Stockholm. The final magnetic calibration of the Astrid-2 satellite was done at the Lovoe Magnetic Observatory under the Geological...... of the magnetometer readings in each position were related to the field magnitudes from the Observatory, and a least squares fit for the 9 magnetometer calibration parameters was performed (3 offsets, 3 scale values and 3 inter-axes angles). After corrections for the magnetometer digital-to-analogue converters...... fit calibration parameters. Owing to time shortage, we did not evaluate the temperature coefficients of the flight sensor calibration parameters. However, this was done for an identical flight spare magnetometer sensor at the magnetic coil facility belonging to the Technical University of Braunschweig...

  17. Field calibration of cup anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, L.; Jensen, G.; Hansen, A.; Kirkegaard, P.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statistical significance of the calibration expressions. It is concluded that the method has the advantage that many anemometers can be calibrated accurately with a minimum of work and cost. The obvious disadvantage is that the calibration of a set of anemometers may take more than one month in order to have wind speeds covering a sufficiently large magnitude range in a wind direction sector where we can be sure that the instruments are exposed to identical, simultaneous wind flows. Another main conclusion is that statistical uncertainty must be carefully evaluated since the individual 10 minute wind-speed averages are not statistically independent. (au)

  18. On the absolute calibration of SO2 cameras

    Directory of Open Access Journals (Sweden)

    P. Lübcke

    2013-03-01

    Full Text Available Sulphur dioxide emission rate measurements are an important tool for volcanic monitoring and eruption risk assessment. The SO2 camera technique remotely measures volcanic emissions by analysing the ultraviolet absorption of SO2 in a narrow spectral window between 300 and 320 nm using solar radiation scattered in the atmosphere. The SO2 absorption is selectively detected by mounting band-pass interference filters in front of a two-dimensional, UV-sensitive CCD detector. One important step for correct SO2 emission rate measurements that can be compared with other measurement techniques is a correct calibration. This requires conversion from the measured optical density to the desired SO2 column density (CD. The conversion factor is most commonly determined by inserting quartz cells (cuvettes with known amounts of SO2 into the light path. Another calibration method uses an additional narrow field-of-view Differential Optical Absorption Spectroscopy system (NFOV-DOAS, which measures the column density simultaneously in a small area of the camera's field-of-view. This procedure combines the very good spatial and temporal resolution of the SO2 camera technique with the more accurate column densities obtainable from DOAS measurements. This work investigates the uncertainty of results gained through the two commonly used, but quite different, calibration methods (DOAS and calibration cells. Measurements with three different instruments, an SO2 camera, a NFOV-DOAS system and an Imaging DOAS (I-DOAS, are presented. We compare the calibration-cell approach with the calibration from the NFOV-DOAS system. The respective results are compared with measurements from an I-DOAS to verify the calibration curve over the spatial extent of the image. The results show that calibration cells, while working fine in some cases, can lead to an overestimation of the SO2 CD by up to 60% compared with CDs from the DOAS measurements. Besides these errors of calibration

  19. SCODA para el Desarrollo de Sistemas Multiagente

    Directory of Open Access Journals (Sweden)

    Jesús A. Román

    2011-12-01

    Full Text Available El planteamiento de implementar sistemas multiagente de forma que puedan reutilizarse con distintos objetivos, dota a los desarrolladores de una metodología más eficaz en sus fines. Este artículo presenta SCODA, una arquitectura basada en cinco principios: estandaridad, especialización, facilidad de implementación, reutilización y computación distribuida. SCODA pretende facilitar el desarrollo de sistemas multiagente, basándose en el concepto de pequeños grupos de agentes denominados Comunidades Inteligentes Especializadas (CIE. Las CIE cuentan con funcionalidades específicas que permiten llevar a cabo la implementación de sistemas multiagente de forma escalable, dentro del marco de SCODA, pudiendo ser reutilizadas en diversos desarrollos.

  20. Contexto General de los Sistemas Agrarios

    Directory of Open Access Journals (Sweden)

    Vélez Escobar Norberto

    1989-12-01

    Full Text Available Esta ponencia introdujo y delimitó el campo de trabajo para el panel: Formas o Sistemas de Producción Agraria. En ella se presentó y discutió la definición del concepto de FORMA DE PRODUCCION e igualmente planteó la taxonomía más general o "agrupamientos" de los sistemas de producción agraria en Colombia. Se identificaron cinco grupos de formas, en proceso de estructuración, empresariales, campesinas, de economía natural y experimentales; y a continuación se caracterizó y explicó cada uno de los cinco agrupamientos. La ponencia terminó sustentando la validez del trabajo académico basado en el enfoque de sistemas y presentó la evolución reciente de esta forma de trabajo en la Universidad Nacional, Seccional Medellín.

  1. The ATLAS Inner Detector commissioning and calibration

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdelalim, Ahmed Ali; Abdesselam, Abdelouahab; Abdinov, Ovsat; Abi, Babak; Abolins, Maris; Abramowicz, Halina; Abreu, Henso; Acharya, Bobby Samir; Adams, David; Addy, Tetteh; Adelman, Jahred; Adorisio, Cristina; Adragna, Paolo; Adye, Tim; Aefsky, Scott; Aguilar-Saavedra, Juan Antonio; Aharrouche, Mohamed; Ahlen, Steven; Ahles, Florian; Ahmad, Ashfaq; Ahsan, Mahsana; Aielli, Giulio; Akdogan, Taylan; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov , Andrei; Aktas, Adil; Alam, Mohammad; Alam, Muhammad Aftab; Albrand, Solveig; Aleksa, Martin; Aleksandrov, Igor; Alexa, Calin; Alexander, Gideon; Alexandre, Gauthier; Alexopoulos, Theodoros; Alhroob, Muhammad; Aliev, Malik; Alimonti, Gianluca; Alison, John; Aliyev, Magsud; Allport, Phillip; Allwood-Spiers, Sarah; Almond, John; Aloisio, Alberto; Alon, Raz; Alonso, Alejandro; Alviggi, Mariagrazia; Amako, Katsuya; Amelung, Christoph; Amorim, Antonio; Amorós, Gabriel; Amram, Nir; Anastopoulos, Christos; Andeen, Timothy; Anders, Christoph Falk; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Anduaga, Xabier; Angerami, Aaron; Anghinolfi, Francis; Anjos, Nuno; Annovi, Alberto; Antonaki, Ariadni; Antonelli, Mario; Antonelli, Stefano; Antos, Jaroslav; Antunovic, Bijana; Anulli, Fabio; Aoun, Sahar; Arabidze, Giorgi; Aracena, Ignacio; Arai, Yasuo; Arce, Ayana; Archambault, John-Paul; Arfaoui, Samir; Arguin, Jean-Francois; Argyropoulos, Theodoros; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnault, Christian; Artamonov, Andrei; Arutinov, David; Asai, Makoto; Asai, Shoji; Silva, José; Asfandiyarov, Ruslan; Ask, Stefan; Åsman, Barbro; Asner, David; Asquith, Lily; Assamagan, Ketevi; Astvatsatourov, Anatoli; Atoian, Grigor; Auerbach, Benjamin; Augsten, Kamil; Aurousseau, Mathieu; Austin, Nicholas; Avolio, Giuseppe; Avramidou, Rachel Maria; Ay, Cano; Azuelos, Georges; Azuma, Yuya; Baak, Max; Bach, Andre; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Badescu, Elisabeta; Bagnaia, Paolo; Bai, Yu; Bain, Travis; Baines, John; Baker, Mark; Baker, Oliver Keith; Baker, Sarah; Baltasar Dos Santos Pedrosa, Fernando; Banas, Elzbieta; Banerjee, Piyali; Banerjee, Swagato; Banfi, Danilo; Bangert, Andrea Michelle; Bansal, Vikas; Baranov, Sergei; Barashkou, Andrei; Barber, Tom; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Bardin, Dmitri; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnett, Bruce; Barnett, Michael; Baroncelli, Antonio; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Barrillon, Pierre; Bartoldus, Rainer; Bartsch, Detlef; Bates, Richard; Batkova, Lucia; Batley, Richard; Battaglia, Andreas; Battistin, Michele; Bauer, Florian; Bawa, Harinder Singh; Bazalova, Magdalena; Beare, Brian; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Graham; Beck, Hans Peter; Beckingham, Matthew; Becks, Karl-Heinz; Beddall, Ayda; Beddall, Andrew; Bednyakov, Vadim; Bee, Christopher; Begel, Michael; Behar Harpaz, Silvia; Behera, Prafulla; Beimforde, Michael; Belanger-Champagne, Camille; Bell, Paul; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellina, Francesco; Bellomo, Massimiliano; Belloni, Alberto; Belotskiy, Konstantin; Beltramello, Olga; Ben Ami, Sagi; Benary, Odette; Benchekroun, Driss; Bendel, Markus; Benedict, Brian Hugues; Benekos, Nektarios; Benhammou, Yan; Benjamin, Douglas; Benoit, Mathieu; Bensinger, James; Benslama, Kamal; Bentvelsen, Stan; Beretta, Matteo; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Berglund, Elina; Beringer, Jürg; Bernabéu , José; Bernat, Pauline; Bernhard, Ralf; Bernius, Catrin; Berry, Tracey; Bertin, Antonio; Besana, Maria Ilaria; Besson, Nathalie; Bethke, Siegfried; Bianchi, Riccardo-Maria; Bianco, Michele; Biebel, Otmar; Biesiada, Jed; Biglietti, Michela; Bilokon, Halina; Bindi, Marcello; Bingul, Ahmet; Bini, Cesare; Biscarat, Catherine; Bitenc, Urban; Black, Kevin; Blair, Robert; Blanchard, Jean-Baptiste; Blanchot, Georges; Blocker, Craig; Blondel, Alain; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bocci, Andrea; Boehler, Michael; Boek, Jennifer; Boelaert, Nele; Böser, Sebastian; Bogaerts, Joannes Andreas; Bogouch, Andrei; Bohm, Christian; Bohm, Jan; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Bondarenko, Valery; Bondioli, Mario; Boonekamp, Maarten; Bordoni, Stefania; Borer, Claudia; Borisov, Anatoly; Borissov, Guennadi; Borjanovic, Iris; Borroni, Sara; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boterenbrood, Hendrik; Bouchami, Jihene; Boudreau, Joseph; Bouhova-Thacker, Evelina Vassileva; Boulahouache, Chaouki; Bourdarios, Claire; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozovic-Jelisavcic, Ivanka; Bracinik, Juraj; Braem, André; Branchini, Paolo; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brelier, Bertrand; Bremer, Johan; Brenner, Richard; Bressler, Shikma; Britton, Dave; Brochu, Frederic; Brock, Ian; Brock, Raymond; Brodet, Eyal; Bromberg, Carl; Brooijmans, Gustaaf; Brooks, William; Brown, Gareth; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Brunet, Sylvie; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Bucci, Francesca; Buchanan, James; Buchholz, Peter; Buckley, Andrew; Budagov, Ioulian; Budick, Burton; Büscher, Volker; Bugge, Lars; Bulekov, Oleg; Bunse, Moritz; Buran, Torleiv; Burckhart, Helfried; Burdin, Sergey; Burgess, Thomas; Burke, Stephen; Busato, Emmanuel; Bussey, Peter; Buszello, Claus-Peter; Butin, Françcois; Butler, Bart; Butler, John; Buttar, Craig; Butterworth, Jonathan; Byatt, Tom; Caballero, Jose; Cabrera Urbán, Susana; Caforio, Davide; Cakir, Orhan; Calafiura, Paolo; Calderini, Giovanni; Calfayan, Philippe; Calkins, Robert; Caloba, Luiz; Calvet, David; Camarri, Paolo; Cameron, David; Campana, Simone; Campanelli, Mario; Canale, Vincenzo; Canelli, Florencia; Canepa, Anadi; Cantero, Josu; Capasso, Luciano; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capua, Marcella; Caputo, Regina; Caramarcu, Costin; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Bryan; Caron, Sascha; Carrillo Montoya, German D.; Carron Montero, Sebastian; Carter, Antony; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Cascella, Michele; Castaneda Hernandez, Alfredo Martin; Castaneda-Miranda, Elizabeth; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Cataldi, Gabriella; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Cattani, Giordano; Caughron, Seth; Cavalleri, Pietro; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Cerqueira, Augusto Santiago; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chan, Kevin; Chapman, John Derek; Chapman, John Wehrley; Chareyre, Eve; Charlton, Dave; Chavda, Vikash; Cheatham, Susan; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chen, Hucheng; Chen, Shenjian; Chen, Xin; Cheplakov, Alexander; Chepurnov, Vladimir; Cherkaoui El Moursli, Rajaa; Tcherniatine, Valeri; Chesneanu, Daniela; Cheu, Elliott; Cheung, Sing-Leung; Chevalier, Laurent; Chevallier, Florent; Chiefari, Giovanni; Chikovani, Leila; Childers, John Taylor; Chilingarov, Alexandre; Chiodini, Gabriele; Chizhov, Mihail; Choudalakis, Georgios; Chouridou, Sofia; Christidi, Illectra-Athanasia; Christov, Asen; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Ciapetti, Guido; Ciftci, Abbas Kenan; Ciftci, Rena; Cinca, Diane; Cindro, Vladimir; Ciobotaru, Matei Dan; Ciocca, Claudia; Ciocio, Alessandra; Cirilli, Manuela; Clark, Allan G.; Clark, Philip James; Cleland, Bill; Clemens, Jean-Claude; Clement, Benoit; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H.; Coggeshall, James; Cogneras, Eric; Colijn, Auke-Pieter; Collard, Caroline; Collins, Neil; Collins-Tooth, Christopher; Collot, Johann; Colon, German; Conde Muiño, Patricia; Coniavitis, Elias; Conidi, Maria Chiara; Consonni, Michele; Constantinescu, Serban; Conta, Claudio; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cooper-Smith, Neil; Copic, Katherine; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Corso-Radu, Alina; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Costin, Tudor; Côté, David; Coura Torres, Rodrigo; Courneyea, Lorraine; Cowan, Glen; Cowden, Christopher; Cox, Brian; Cranmer, Kyle; Cranshaw, Jack; Cristinziani, Markus; Crosetti, Giovanni; Crupi, Roberto; Crépé-Renaudin, Sabine; Cuenca Almenar, Cristóbal; Cuhadar Donszelmann, Tulay; Curatolo, Maria; Curtis, Chris; Cwetanski, Peter; Czyczula, Zofia; D'Auria, Saverio; D'Onofrio, Monica; D'Orazio, Alessia; Da Via, Cinzia; Dabrowski, Wladyslaw; Dai, Tiesheng; Dallapiccola, Carlo; Dallison, Steve; Daly, Colin; Dam, Mogens; Danielsson, Hans Olof; Dannheim, Dominik; Dao, Valerio; Darbo, Giovanni; Darlea, Georgiana Lavinia; Davey, Will; Davidek, Tomas; Davidson, Nadia; Davidson, Ruth; Davies, Merlin; Davison, Adam; Dawson, Ian; Daya, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Castro Faria Salgado, Pedro; De Cecco, Sandro; de Graat, Julien; De Groot, Nicolo; de Jong, Paul; De Mora, Lee; De Oliveira Branco, Miguel; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dean, Simon; Dedovich, Dmitri; Degenhardt, James; Dehchar, Mohamed; Del Papa, Carlo; Del Peso, Jose; Del Prete, Tarcisio; Dell'Acqua, Andrea; Dell'Asta, Lidia; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; Demers, Sarah; Demichev, Mikhail; Demirkoz, Bilge; Deng, Jianrong; Deng, Wensheng; Denisov, Sergey; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Deviveiros, Pier-Olivier; Dewhurst, Alastair; DeWilde, Burton; Dhaliwal, Saminder; Dhullipudi, Ramasudhakar; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Luise, Silvestro; Di Mattia, Alessandro; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Diaz, Marco Aurelio; Diblen, Faruk; Diehl, Edward; Dietrich, Janet; Dietzsch, Thorsten; Diglio, Sara; Dindar Yagci, Kamile; Dingfelder, Jochen; Dionisi, Carlo; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djilkibaev, Rashid; Djobava, Tamar; do Vale, Maria Aline Barros; Do Valle Wemans, André; Doan, Thi Kieu Oanh; Dobos, Daniel; Dobson, Ellie; Dobson, Marc; Doglioni, Caterina; Doherty, Tom; Dolejsi, Jiri; Dolenc, Irena; Dolezal, Zdenek; Dolgoshein, Boris; Dohmae, Takeshi; Donega, Mauro; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dos Anjos, Andre; Dotti, Andrea; Dova, Maria-Teresa; Doxiadis, Alexander; Doyle, Tony; Drasal, Zbynek; Dris, Manolis; Dubbert, Jörg; Duchovni, Ehud; Duckeck, Guenter; Dudarev, Alexey; Dudziak, Fanny; Dührssen , Michael; Duflot, Laurent; Dufour, Marc-Andre; Dunford, Monica; Duran Yildiz, Hatice; Duxfield, Robert; Dwuznik, Michal; Düren, Michael; Ebenstein, William; Ebke, Johannes; Eckweiler, Sebastian; Edmonds, Keith; Edwards, Clive; Egorov, Kirill; Ehrenfeld, Wolfgang; Ehrich, Thies; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Eisenhandler, Eric; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Ellis, Katherine; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Engelmann, Roderich; Engl, Albert; Epp, Brigitte; Eppig, Andrew; Erdmann, Johannes; Ereditato, Antonio; Eriksson, Daniel; Ermoline, Iouri; Ernst, Jesse; Ernst, Michael; Ernwein, Jean; Errede, Deborah; Errede, Steven; Ertel, Eugen; Escalier, Marc; Escobar, Carlos; Espinal Curull, Xavier; Esposito, Bellisario; Etienvre, Anne-Isabelle; Etzion, Erez; Evans, Hal; Fabbri, Laura; Fabre, Caroline; Facius, Katrine; Fakhrutdinov, Rinat; Falciano, Speranza; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farley, Jason; Farooque, Trisha; Farrington, Sinead; Farthouat, Philippe; Fassnacht, Patrick; Fassouliotis, Dimitrios; Fatholahzadeh, Baharak; Fayard, Louis; Fayette, Florent; Febbraro, Renato; Federic, Pavol; Fedin, Oleg; Fedorko, Woiciech; Feligioni, Lorenzo; Felzmann, Ulrich; Feng, Cunfeng; Feng, Eric; Fenyuk, Alexander; Ferencei, Jozef; Ferland, Jonathan; Fernandes, Bruno; Fernando, Waruna; Ferrag, Samir; Ferrando, James; Ferrara, Valentina; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferrer, Antonio; Ferrer, Maria Lorenza; Ferrere, Didier; Ferretti, Claudio; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filippas, Anastasios; Filthaut, Frank; Fincke-Keeler, Margret; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Gordon; Fisher, Matthew; Flechl, Martin; Fleck, Ivor; Fleckner, Johanna; Fleischmann, Philipp; Fleischmann, Sebastian; Flick, Tobias; Flores Castillo, Luis; Flowerdew, Michael; Fonseca Martin, Teresa; Formica, Andrea; Forti, Alessandra; Fortin, Dominique; Fournier, Daniel; Fowler, Andrew; Fowler, Ken; Fox, Harald; Francavilla, Paolo; Franchino, Silvia; Francis, David; Franklin, Melissa; Franz, Sebastien; Fraternali, Marco; Fratina, Sasa; Freestone, Julian; French, Sky; Froeschl, Robert; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gadfort, Thomas; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Gallas, Elizabeth; Gallo, Valentina Santina; Gallop, Bruce; Gallus, Petr; Galyaev, Eugene; Gan, K K; Gao, Yongsheng; Gaponenko, Andrei; Garcia-Sciveres, Maurice; García, Carmen; García Navarro, José Enrique; Gardner, Robert; Garelli, Nicoletta; Garitaonandia, Hegoi; Garonne, Vincent; Gatti, Claudio; Gaudio, Gabriella; Gautard, Valerie; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gee, Norman; Geich-Gimbel, Christoph; Gellerstedt, Karl; Gemme, Claudia; Genest, Marie-Hélène; Gentile, Simonetta; Georgatos, Fotios; George, Simon; Gershon, Avi; Ghazlane, Hamid; Ghodbane, Nabil; Giacobbe, Benedetto; Giagu, Stefano; Giakoumopoulou, Victoria; Giangiobbe, Vincent; Gianotti, Fabiola; Gibbard, Bruce; Gibson, Adam; Gibson, Stephen; Gilbert, Laura; Gilchriese, Murdock; Gilewsky, Valentin; Gingrich, Douglas; Ginzburg, Jonatan; Giokaris, Nikos; Giordani, MarioPaolo; Giordano, Raffaele; Giorgi, Francesco Michelangelo; Giovannini, Paola; Giraud, Pierre-Francois; Girtler, Peter; Giugni, Danilo; Giusti, Paolo; Gjelsten, Børge Kile; Gladilin, Leonid; Glasman, Claudia; Glazov, Alexandre; Glitza, Karl-Walter; Glonti, George; Godfrey, Jennifer; Godlewski, Jan; Goebel, Martin; Göpfert, Thomas; Goeringer, Christian; Gössling, Claus; Göttfert, Tobias; Goggi, Virginio; Goldfarb, Steven; Goldin, Daniel; Golling, Tobias; Gomes, Agostinho; Gomez Fajardo, Luz Stella; Gonçcalo, Ricardo; Gonella, Laura; Gong, Chenwei; González de la Hoz, Santiago; Gonzalez Silva, Laura; Gonzalez-Sevilla, Sergio; Goodson, Jeremiah Jet; Goossens, Luc; Gordon, Howard; Gorelov, Igor; Gorfine, Grant; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Gosdzik, Bjoern; Gosselink, Martijn; Gostkin, Mikhail Ivanovitch; Gough Eschrich, Ivo; Gouighri, Mohamed; Goujdami, Driss; Goulette, Marc Phillippe; Goussiou, Anna; Goy, Corinne; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Grau, Nathan; Gray, Heather; Gray, Julia Ann; Graziani, Enrico; Green, Barry; Greenshaw, Timothy; Greenwood, Zeno Dixon; Gregor, Ingrid-Maria; Grenier, Philippe; Griesmayer, Erich; Griffiths, Justin; Grigalashvili, Nugzar; Grillo, Alexander; Grimm, Kathryn; Grinstein, Sebastian; Grishkevich, Yaroslav; Groh, Manfred; Groll, Marius; Gross, Eilam; Grosse-Knetter, Joern; Groth-Jensen, Jacob; Grybel, Kai; Guicheney, Christophe; Guida, Angelo; Guillemin, Thibault; Guler, Hulya; Gunther, Jaroslav; Guo, Bin; Gusakov, Yury; Gutierrez, Andrea; Gutierrez, Phillip; Guttman, Nir; Gutzwiller, Olivier; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haas, Stefan; Haber, Carl; Hadavand, Haleh Khani; Hadley, David; Haefner, Petra; Hajduk, Zbigniew; Hakobyan, Hrachya; Haller, Johannes; Hamacher, Klaus; Hamilton, Andrew; Hamilton, Samuel; Han, Liang; Hanagaki, Kazunori; Hance, Michael; Handel, Carsten; Hanke, Paul; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, John Renner; Hansen, Peter Henrik; Hansl-Kozanecka, Traudl; Hansson, Per; Hara, Kazuhiko; Hare, Gabriel; Harenberg, Torsten; Harrington, Robert; Harris, Orin; Harrison, Karl; Hartert, Jochen; Hartjes, Fred; Harvey, Alex; Hasegawa, Satoshi; Hasegawa, Yoji; Hassani, Samira; Haug, Sigve; Hauschild, Michael; Hauser, Reiner; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hayakawa, Takashi; Hayward, Helen; Haywood, Stephen; Head, Simon; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heinemann, Beate; Heisterkamp, Simon; Helary, Louis; Heller, Mathieu; Hellman, Sten; Helsens, Clement; Hemperek, Tomasz; Henderson, Robert; Henke, Michael; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Hensel, Carsten; Henß, Tobias; Hernández Jiménez, Yesenia; Hershenhorn, Alon David; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hessey, Nigel; Higón-Rodriguez, Emilio; Hill, John; Hiller, Karl Heinz; Hillert, Sonja; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hirose, Minoru; Hirsch, Florian; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoffman, Julia; Hoffmann, Dirk; Hohlfeld, Marc; Holy, Tomas; Holzbauer, Jenny; Homma, Yasuhiro; Horazdovsky, Tomas; Hori, Takuya; Horn, Claus; Horner, Stephan; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howe, Travis; Hrivnac, Julius; Hryn'ova, Tetiana; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Huang, Guang Shun; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Hurwitz, Martina; Husemann, Ulrich; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Idarraga, John; Iengo, Paolo; Igonkina, Olga; Ikegami, Yoichi; Ikeno, Masahiro; Ilchenko, Yuri; Iliadis, Dimitrios; Ince, Tayfun; Ioannou, Pavlos; Iodice, Mauro; Irles Quiles, Adrian; Ishikawa, Akimasa; Ishino, Masaya; Ishmukhametov, Renat; Isobe, Tadaaki; Issever, Cigdem; Istin, Serhat; Itoh, Yuki; Ivashin, Anton; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jackson, Brett; Jackson, John; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakubek, Jan; Jana, Dilip; Jankowski, Ernest; Jansen, Eric; Jantsch, Andreas; Janus, Michel; Jarlskog, Göran; Jeanty, Laura; Jen-La Plante, Imai; Jenni, Peter; Jež, Pavel; Jézéquel, Stéphane; Ji, Weina; Jia, Jiangyong; Jiang, Yi; Jimenez Belenguer, Marcos; Jin, Shan; Jinnouchi, Osamu; Joffe, David; Johansen, Marianne; Johansson, Erik; Johansson, Per; Johnert, Sebastian; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Jorge, Pedro; Joseph, John; Juranek, Vojtech; Jussel, Patrick; Kabachenko, Vasily; Kaci, Mohammed; Kaczmarska, Anna; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kaiser, Steffen; Kajomovitz, Enrique; Kalinin, Sergey; Kalinovskaya, Lidia; Kama, Sami; Kanaya, Naoko; Kaneda, Michiru; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kaplon, Jan; Kar, Deepak; Karagounis, Michael; Karagoz, Muge; Karnevskiy, Mikhail; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kasmi, Azzedine; Kass, Richard; Kastanas, Alex; Kastoryano, Michael; Kataoka, Mayuko; Kataoka, Yousuke; Katsoufis, Elias; Katzy, Judith; Kaushik, Venkatesh; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kayl, Manuel; Kayumov, Fred; Kazanin, Vassili; Kazarinov, Makhail; Keates, James Robert; Keeler, Richard; Keener, Paul; Kehoe, Robert; Keil, Markus; Kekelidze, George; Kelly, Marc; Kenyon, Mike; Kepka, Oldrich; Kerschen, Nicolas; Kerševan, Borut Paul; Kersten, Susanne; Kessoku, Kohei; Khakzad, Mohsen; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharchenko, Dmitri; Khodinov, Alexander; Khomich, Andrei; Khoriauli, Gia; Khovanskiy, Nikolai; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hyeon Jin; Kim, Min Suk; Kim, Peter; Kim, Shinhong; Kind, Oliver; Kind, Peter; King, Barry; Kirk, Julie; Kirsch, Guillaume; Kirsch, Lawrence; Kiryunin, Andrey; Kisielewska, Danuta; Kittelmann, Thomas; Kiyamura, Hironori; Kladiva, Eduard; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klemetti, Miika; Klier, Amit; Klimentov, Alexei; Klingenberg, Reiner; Klinkby, Esben; Klioutchnikova, Tatiana; Klok, Peter; Klous, Sander; Kluge, Eike-Erik; Kluge, Thomas; Kluit, Peter; Klute, Markus; Kluth, Stefan; Knecht, Neil; Kneringer, Emmerich; Ko, Byeong Rok; Kobayashi, Tomio; Kobel, Michael; Koblitz, Birger; Kocian, Martin; Kocnar, Antonin; Kodys, Peter; Köneke, Karsten; König, Adriaan; Koenig, Sebastian; Köpke, Lutz; Koetsveld, Folkert; Koevesarki, Peter; Koffas, Thomas; Koffeman, Els; Kohn, Fabian; Kohout, Zdenek; Kohriki, Takashi; Kolanoski, Hermann; Kolesnikov, Vladimir; Koletsou, Iro; Koll, James; Kollar, Daniel; Kolos, Serguei; Kolya, Scott; Komar, Aston; Komaragiri, Jyothsna Rani; Kondo, Takahiko; Kono, Takanori; Konoplich, Rostislav; Konovalov, Serguei; Konstantinidis, Nikolaos; Koperny, Stefan; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korolkov, Ilya; Korolkova, Elena; Korotkov, Vladislav; Kortner, Oliver; Kortner, Sandra; Kostka, Peter; Kostyukhin, Vadim; Kotov, Serguei; Kotov, Vladislav; Kotov, Konstantin; Kourkoumelis, Christine; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Henri; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kral, Vlastimil; Kramarenko, Viktor; Kramberger, Gregor; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, James; Kreisel, Arik; Krejci, Frantisek; Kretzschmar, Jan; Krieger, Nina; Krieger, Peter; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Krumshteyn, Zinovii; Kubota, Takashi; Kuehn, Susanne; Kugel, Andreas; Kuhl, Thorsten; Kuhn, Dietmar; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kummer, Christian; Kuna, Marine; Kunkle, Joshua; Kupco, Alexander; Kurashige, Hisaya; Kurata, Masakazu; Kurochkin, Yurii; Kus, Vlastimil; Kwee, Regina; La Rosa, Alessandro; La Rotonda, Laura; Labbe, Julien; Lacasta, Carlos; Lacava, Francesco; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Rémi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Lamanna, Massimo; Lampen, Caleb; Lampl, Walter; Lancon, Eric; Landgraf, Ulrich; Landon, Murrough; Lane, Jenna; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Lanza, Agostino; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Larner, Aimee; Lassnig, Mario; Laurelli, Paolo; Lavrijsen, Wim; Laycock, Paul; Lazarev, Alexandre; Lazzaro, Alfio; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Menedeu, Eve; Lebedev, Alexander; Lebel, Céline; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Hurng-Chun; Lee, Jason; Lee, Shih-Chang; Lefebvre, Michel; Legendre, Marie; LeGeyt, Benjamin; Legger, Federica; Leggett, Charles; Lehmacher, Marc; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leitner, Rupert; Lellouch, Daniel; Lellouch, Jeremie; Lendermann, Victor; Leney, Katharine; Lenz, Tatiana; Lenzen, Georg; Lenzi, Bruno; Leonhardt, Kathrin; Leroy, Claude; Lessard, Jean-Raphael; Lester, Christopher; Leung Fook Cheong, Annabelle; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Leyton, Michael; Li, Haifeng; Li, Xuefei; Liang, Zhihua; Liang, Zhijun; Liberti, Barbara; Lichard, Peter; Lichtnecker, Markus; Lie, Ki; Liebig, Wolfgang; Lilley, Joseph; Limosani, Antonio; Limper, Maaike; Lin, Simon; Linnemann, James; Lipeles, Elliot; Lipinsky, Lukas; Lipniacka, Anna; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Chuanlei; Liu, Dong; Liu, Hao; Liu, Jianbei; Liu, Minghui; Liu, Tiankuan; Liu, Yanwen; Livan, Michele; Lleres, Annick; Lloyd, Stephen; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Lockwitz, Sarah; Loddenkoetter, Thomas; Loebinger, Fred; Loginov, Andrey; Loh, Chang Wei; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Long, Robin Eamonn; Lopes, Lourenco; Lopez Mateos, David; Losada, Marta; Loscutoff, Peter; Lou, Xinchou; Lounis, Abdenour; Loureiro, Karina; Lovas, Lubomir; Love, Jeremy; Love, Peter; Lowe, Andrew; Lu, Feng; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Ludwig, Andreas; Ludwig, Dörthe; Ludwig, Inga; Luehring, Frederick; Lumb, Debra; Luminari, Lamberto; Lund, Esben; Lund-Jensen, Bengt; Lundberg, Björn; Lundberg, Johan; Lundquist, Johan; Lynn, David; Lys, Jeremy; Lytken, Else; Ma, Hong; Ma, Lian Liang; Macana Goia, Jorge Andres; Maccarrone, Giovanni; Macchiolo, Anna; Maček, Boštjan; Machado Miguens, Joana; Mackeprang, Rasmus; Madaras, Ronald; Mader, Wolfgang; Maenner, Reinhard; Maeno, Tadashi; Mättig, Peter; Mättig, Stefan; Magalhaes Martins, Paulo Jorge; Magradze, Erekle; Mahalalel, Yair; Mahboubi, Kambiz; Mahmood, A.; Maiani, Camilla; Maidantchik, Carmen; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makouski, Mikhail; Makovec, Nikola; Malecki, Piotr; Malecki, Pawel; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mambelli, Marco; Mameghani, Raphael; Mamuzic, Judita; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Mangeard, Pierre-Simon; Manjavidze, Ioseb; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mapelli, Alessandro; Mapelli, Livio; March , Luis; Marchand, Jean-Francois; Marchese, Fabrizio; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marroquim, Fernando; Marshall, Zach; Marti-Garcia, Salvador; Martin, Alex; Martin, Andrew; Martin, Brian; Martin, Brian; Martin, Franck Francois; Martin, Jean-Pierre; Martin, Tim; Martin dit Latour, Bertrand; Martinez, Mario; Martinez Outschoorn, Verena; Martyniuk, Alex; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massol, Nicolas; Mastroberardino, Anna; Masubuchi, Tatsuya; Matricon, Pierre; Matsunaga, Hiroyuki; Matsushita, Takashi; Mattravers, Carly; Maxfield, Stephen; Mayne, Anna; Mazini, Rachid; Mazur, Michael; Mc Donald, Jeffrey; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCubbin, Norman; McFarlane, Kenneth; McGlone, Helen; Mchedlidze, Gvantsa; McMahon, Steve; McPherson, Robert; Meade, Andrew; Mechnich, Joerg; Mechtel, Markus; Medinnis, Mike; Meera-Lebbai, Razzak; Meguro, Tatsuma; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meirose, Bernhard; Melachrinos, Constantinos; Mellado Garcia, Bruce Rafael; Mendoza Navas, Luis; Meng, Zhaoxia; Menke, Sven; Meoni, Evelin; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Jean-Pierre; Meyer, Jochen; Meyer, Joerg; Meyer, Thomas Christian; Meyer, W. Thomas; Miao, Jiayuan; Michal, Sebastien; Micu, Liliana; Middleton, Robin; Migas, Sylwia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Miller, David; Mills, Corrinne; Mills, Bill; Milov, Alexander; Milstead, David; Milstein, Dmitry; Minaenko, Andrey; Miñano, Mercedes; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mirabelli, Giovanni; Misawa, Shigeki; Misiejuk, Andrzej; Mitrevski, Jovan; Mitsou, Vasiliki A.; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Moed, Shulamit; Moeller, Victoria; Mönig, Klaus; Möser, Nicolas; Mohr, Wolfgang; Mohrdieck-Möck, Susanne; Moles-Valls, Regina; Molina-Perez, Jorge; Monk, James; Monnier, Emmanuel; Montesano, Simone; Monticelli, Fernando; Moore, Roger; Mora Herrera, Clemencia; Moraes, Arthur; Morais, Antonio; Morel, Julien; Morello, Gianfranco; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morii, Masahiro; Morley, Anthony Keith; Mornacchi, Giuseppe; Morozov, Sergey; Morris, John; Moser, Hans-Guenther; Mosidze, Maia; Moss, Josh; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Mudrinic, Mihajlo; Mueller, Felix; Mueller, James; Mueller, Klemens; Müller, Thomas; Muenstermann, Daniel; Muir, Alex; Munwes, Yonathan; Murillo Garcia, Raul; Murray, Bill; Mussche, Ido; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nadal, Jordi; Nagai, Koichi; Nagano, Kunihiro; Nagasaka, Yasushi; Nairz, Armin Michael; Nakamura, Koji; Nakano, Itsuo; Nakatsuka, Hiroki; Nanava, Gizo; Napier, Austin; Nash, Michael; Nation, Nigel; Nattermann, Till; Naumann, Thomas; Navarro, Gabriela; Nderitu, Simon Kirichu; Neal, Homer; Nebot, Eduardo; Nechaeva, Polina; Negri, Andrea; Negri, Guido; Nelson, Andrew; Nelson, Timothy Knight; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neusiedl, Andrea; Neves, Ricardo; Nevski, Pavel; Newcomer, Mitchel; Nickerson, Richard; Nicolaidou, Rosy; Nicolas, Ludovic; Nicoletti, Giovanni; Nicquevert, Bertrand; Niedercorn, Francois; Nielsen, Jason; Nikiforov, Andriy; Nikolaev, Kirill; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Henrik; Nilsson, Paul; Nisati, Aleandro; Nishiyama, Tomonori; Nisius, Richard; Nodulman, Lawrence; Nomachi, Masaharu; Nomidis, Ioannis; Nordberg, Markus; Nordkvist, Bjoern; Notz, Dieter; Novakova, Jana; Nozaki, Mitsuaki; Nožička, Miroslav; Nugent, Ian Michael; Nuncio-Quiroz, Adriana-Elizabeth; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Ochi, Atsuhiko; Oda, Susumu; Odaka, Shigeru; Odier, Jerome; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohshima, Takayoshi; Ohshita, Hidetoshi; Ohsugi, Takashi; Okada, Shogo; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olchevski, Alexander; Oliveira, Miguel Alfonso; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olivito, Dominick; Olszewski, Andrzej; Olszowska, Jolanta; Omachi, Chihiro; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlov, Iliya; Oropeza Barrera, Cristina; Orr, Robert; Ortega, Eduardo; Osculati, Bianca; Ospanov, Rustem; Osuna, Carlos; Ottersbach, John; Ould-Saada, Farid; Ouraou, Ahmimed; Ouyang, Qun; Owen, Mark; Owen, Simon; Oyarzun, Alejandro; Ozcan, Veysi Erkcan; Ozone, Kenji; Ozturk, Nurcan; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Paganis, Efstathios; Pahl, Christoph; Paige, Frank; Pajchel, Katarina; Palestini, Sandro; Pallin, Dominique; Palma, Alberto; Palmer, Jody; Pan, Yibin; Panagiotopoulou, Evgenia; Panes, Boris; Panikashvili, Natalia; Panitkin, Sergey; Pantea, Dan; Panuskova, Monika; Paolone, Vittorio; Papadopoulou, Theodora; Park, Su-Jung; Park, Woochun; Parker, Andy; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passeri, Antonio; Pastore, Fernanda; Pastore, Francesca; Pásztor , Gabriella; Pataraia, Sophio; Pater, Joleen; Patricelli, Sergio; Pauly, Thilo; Peak, Lawrence; Pecsy, Martin; Pedraza Morales, Maria Isabel; Peleganchuk, Sergey; Peng, Haiping; Penson, Alexander; Penwell, John; Perantoni, Marcelo; Perez, Kerstin; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perez Reale, Valeria; Perini, Laura; Pernegger, Heinz; Perrino, Roberto; Persembe, Seda; Perus, Antoine; Peshekhonov, Vladimir; Petersen, Brian; Petersen, Troels; Petit, Elisabeth; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Petschull, Dennis; Petteni, Michele; Pezoa, Raquel; Phan, Anna; Phillips, Alan; Phillips, Peter William; Piacquadio, Giacinto; Piccinini, Maurizio; Piegaia, Ricardo; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinfold, James; Pinto, Belmiro; Pizio, Caterina; Placakyte, Ringaile; Plamondon, Mathieu; Pleier, Marc-Andre; Poblaguev, Andrei; Poddar, Sahill; Podlyski, Fabrice; Poggioli, Luc; Pohl, Martin; Polci, Francesco; Polesello, Giacomo; Policicchio, Antonio; Polini, Alessandro; Poll, James; Polychronakos, Venetios; Pomeroy, Daniel; Pommès, Kathy; Ponsot, Patrick; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Popule, Jiri; Portell Bueso, Xavier; Porter, Robert; Pospelov, Guennady; Pospisil, Stanislav; Potekhin, Maxim; Potrap, Igor; Potter, Christina; Potter, Christopher; Potter, Keith; Poulard, Gilbert; Poveda, Joaquin; Prabhu, Robindra; Pralavorio, Pascal; Prasad, Srivas; Pravahan, Rishiraj; Pribyl, Lukas; Price, Darren; Price, Lawrence; Prichard, Paul; Prieur, Damien; Primavera, Margherita; Prokofiev, Kirill; Prokoshin, Fedor; Protopopescu, Serban; Proudfoot, James; Prudent, Xavier; Przysiezniak, Helenka; Psoroulas, Serena; Ptacek, Elizabeth; Purdham, John; Purohit, Milind; Puzo, Patrick; Pylypchenko, Yuriy; Qi, Ming; Qian, Jianming; Qian, Weiming; Qin, Zhonghua; Quadt, Arnulf; Quarrie, David; Quayle, William; Quinonez, Fernando; Raas, Marcel; Radeka, Veljko; Radescu, Voica; Radics, Balint; Rador, Tonguc; Ragusa, Francesco; Rahal, Ghita; Rahimi, Amir; Rajagopalan, Srinivasan; Rammensee, Michael; Rammes, Marcus; Rauscher, Felix; Rauter, Emanuel; Raymond, Michel; Read, Alexander Lincoln; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Reinherz-Aronis, Erez; Reinsch, Andreas; Reisinger, Ingo; Reljic, Dusan; Rembser, Christoph; Ren, Zhongliang; Renkel, Peter; Rescia, Sergio; Rescigno, Marco; Resconi, Silvia; Resende, Bernardo; Reznicek, Pavel; Rezvani, Reyhaneh; Richards, Alexander; Richter, Robert; Richter-Was, Elzbieta; Ridel, Melissa; Rijpstra, Manouk; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Rios, Ryan Randy; Riu, Imma; Rizatdinova, Flera; Rizvi, Eram; Roa Romero, Diego Alejandro; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robinson, Mary; Robson, Aidan; Rocha de Lima, Jose Guilherme; Roda, Chiara; Roda Dos Santos, Denis; Rodriguez, Diego; Rodriguez Garcia, Yohany; Roe, Shaun; Røhne, Ole; Rojo, Victoria; Rolli, Simona; Romaniouk, Anatoli; Romanov, Victor; Romeo, Gaston; Romero Maltrana, Diego; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosenbaum, Gabriel; Rosselet, Laurent; Rossetti, Valerio; Rossi, Leonardo Paolo; Rotaru, Marina; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexander; Rozen, Yoram; Ruan, Xifeng; Ruckert, Benjamin; Ruckstuhl, Nicole; Rud, Viacheslav; Rudolph, Gerald; Rühr, Frederik; Ruggieri, Federico; Ruiz-Martinez, Aranzazu; Rumyantsev, Leonid; Rurikova, Zuzana; Rusakovich, Nikolai; Rutherfoord, John; Ruwiedel, Christoph; Ruzicka, Pavel; Ryabov, Yury; Ryan, Patrick; Rybkin, Grigori; Rzaeva, Sevda; Saavedra, Aldo; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sakamoto, Hiroshi; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvachua Ferrando, Belén; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Samset, Björn Hallvard; Sandaker, Heidi; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandhu, Pawan; Sandstroem, Rikard; Sandvoss, Stephan; Sankey, Dave; Sanny, Bernd; Sansoni, Andrea; Santamarina Rios, Cibran; Santoni, Claudio; Santonico, Rinaldo; Saraiva, João; Sarangi, Tapas; Sarkisyan-Grinbaum, Edward; Sarri, Francesca; Sasaki, Osamu; Sasao, Noboru; Satsounkevitch, Igor; Sauvage, Gilles; Savard, Pierre; Savine, Alexandre; Savinov, Vladimir; Sawyer, Lee; Saxon, David; Says, Louis-Pierre; Sbarra, Carla; Sbrizzi, Antonio; Scannicchio, Diana; Schaarschmidt, Jana; Schacht, Peter; Schäfer, Uli; Schaetzel, Sebastian; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R.~Dean; Schamov, Andrey; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Scherzer, Max; Schiavi, Carlo; Schieck, Jochen; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitz, Martin; Schöning, André; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schram, Malachi; Schreiner, Alexander; Schroeder, Christian; Schroer, Nicolai; Schroers, Marcel; Schultes, Joachim; Schultz-Coulon, Hans-Christian; Schumacher, Jan; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwemling, Philippe; Schwienhorst, Reinhard; Schwierz, Rainer; Schwindling, Jerome; Scott, Bill; Searcy, Jacob; Sedykh, Evgeny; Segura, Ester; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Seliverstov, Dmitry; Sellden, Bjoern; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Seuster, Rolf; Severini, Horst; Sevior, Martin; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shank, James; Shao, Qi Tao; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Sherman, Daniel; Sherwood, Peter; Shibata, Akira; Shimojima, Makoto; Shin, Taeksu; Shmeleva, Alevtina; Shochet, Mel; Shupe, Michael; Sicho, Petr; Sidoti, Antonio; Siegert, Frank; Siegrist, James; Sijacki, Djordje; Silbert, Ohad; Silver, Yiftah; Silverstein, Daniel; Silverstein, Samuel; Simak, Vladislav; Simic, Ljiljana; Simion, Stefan; Simmons, Brinick; Simonyan, Margar; Sinervo, Pekka; Sinev, Nikolai; Sipica, Valentin; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skovpen, Kirill; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Sliwa, Krzysztof; Sloper, John erik; Smakhtin, Vladimir; Smirnov, Sergei; Smirnov, Yuri; Smirnova, Lidia; Smirnova, Oxana; Smith, Ben Campbell; Smith, Douglas; Smith, Kenway; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snow, Steve; Snow, Joel; Snuverink, Jochem; Snyder, Scott; Soares, Mara; Sobie, Randall; Sodomka, Jaromir; Soffer, Abner; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Solfaroli Camillocci, Elena; Solodkov, Alexander; Solovyanov, Oleg; Sondericker, John; Sopko, Vit; Sopko, Bruno; Sosebee, Mark; Soukharev, Andrey; Spagnolo, Stefania; Spanò, Francesco; Spighi, Roberto; Spigo, Giancarlo; Spila, Federico; Spiwoks, Ralf; Spousta, Martin; Spreitzer, Teresa; Spurlock, Barry; St. Denis, Richard Dante; Stahl, Thorsten; Stahlman, Jonathan; Stamen, Rainer; Stancu, Stefan Nicolae; Stanecka, Ewa; Stanek, Robert; Stanescu, Cristian; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Stastny, Jan; Stavina, Pavel; Steele, Genevieve; Steinbach, Peter; Steinberg, Peter; Stekl, Ivan; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stevenson, Kyle; Stewart, Graeme; Stockton, Mark; Stoerig, Kathrin; Stoicea, Gabriel; Stonjek, Stefan; Strachota, Pavel; Stradling, Alden; Straessner, Arno; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Stroynowski, Ryszard; Strube, Jan; Stugu, Bjarne; Sturm, Philipp; Su, Dong; Soh, Dart-yin; Sugaya, Yorihito; Sugimoto, Takuya; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Sushkov, Serge; Susinno, Giancarlo; Sutton, Mark; Suzuki, Takuya; Suzuki, Yu; Sykora, Ivan; Sykora, Tomas; Szymocha, Tadeusz; Sánchez, Javier; Ta, Duc; Tackmann, Kerstin; Taffard, Anyes; Tafirout, Reda; Taga, Adrian; Takahashi, Yuta; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Talby, Mossadek; Talyshev, Alexey; Tamsett, Matthew; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tapprogge, Stefan; Tardif, Dominique; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tassi, Enrico; Tatarkhanov, Mous; Taylor, Christopher; Taylor, Frank; Taylor, Geoffrey; Taylor, Ryan P.; Taylor, Wendy; Teixeira-Dias, Pedro; Ten Kate, Herman; Teng, Ping-Kun; Tennenbaum-Katan, Yaniv-David; Terada, Susumu; Terashi, Koji; Terron, Juan; Terwort, Mark; Testa, Marianna; Teuscher, Richard; Therhaag, Jan; Thioye, Moustapha; Thoma, Sascha; Thomas, Juergen; Thompson, Stan; Thompson, Emily; Thompson, Peter; Thompson, Paul; Thompson, Ray; Thomson, Evelyn; Thun, Rudolf; Tic, Tomas; Tikhomirov, Vladimir; Tikhonov, Yury; Tipton, Paul; Tique Aires Viegas, Florbela De Jes; Tisserant, Sylvain; Toczek, Barbara; Todorov, Theodore; Todorova-Nova, Sharka; Toggerson, Brokk; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tomasek, Lukas; Tomasek, Michal; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Tonoyan, Arshak; Topfel, Cyril; Topilin, Nikolai; Torchiani, Ingo; Torrence, Eric; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alesandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Trinh, Thi Nguyet; Tripiana, Martin; Triplett, Nathan; Trischuk, William; Trivedi, Arjun; Trocmé, Benjamin; Troncon, Clara; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiakiris, Menelaos; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsung, Jieh-Wen; Tsuno, Soshi; Tsybychev, Dmitri; Tuggle, Joseph; Turecek, Daniel; Turk Cakir, Ilkay; Turlay, Emmanuel; Tuts, Michael; Twomey, Matthew Shaun; Tylmad, Maja; Tyndel, Mike; Uchida, Kirika; Ueda, Ikuo; Ueno, Ryuichi; Ugland, Maren; Uhlenbrock, Mathias; Uhrmacher, Michael; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Unno, Yoshinobu; Urbaniec, Dustin; Urkovsky, Evgeny; Urquijo, Phillip; Urrejola, Pedro; Usai, Giulio; Uslenghi, Massimiliano; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Vahsen, Sven; Valente, Paolo; Valentinetti, Sara; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Berg, Richard; van der Graaf, Harry; van der Kraaij, Erik; van der Poel, Egge; van der Ster, Daniel; van Eldik, Niels; van Gemmeren, Peter; van Kesteren, Zdenko; van Vulpen, Ivo; Vandelli, Wainer; Vaniachine, Alexandre; Vankov, Peter; Vannucci, Francois; Vari, Riccardo; Varnes, Erich; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vasilyeva, Lidia; Vassilakopoulos, Vassilios; Vazeille, Francois; Vellidis, Constantine; Veloso, Filipe; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vetterli, Michel; Vichou, Irene; Vickey, Trevor; Viehhauser, Georg; Villa, Mauro; Villani, Giulio; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinek, Elisabeth; Vinogradov, Vladimir; Viret, Sébastien; Virzi, Joseph; Vitale , Antonio; Vitells, Ofer; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vlasak, Michal; Vlasov, Nikolai; Vogel, Adrian; Vokac, Petr; Volpi, Matteo; von der Schmitt, Hans; von Loeben, Joerg; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorwerk, Volker; Vos, Marcel; Voss, Rudiger; Voss, Thorsten Tobias; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vu Anh, Tuan; Vudragovic, Dusan; Vuillermet, Raphael; Vukotic, Ilija; Wagner, Peter; Walbersloh, Jorg; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wall, Richard; Wang, Chiho; Wang, Haichen; Wang, Jin; Wang, Song-Ming; Warburton, Andreas; Ward, Patricia; Warsinsky, Markus; Wastie, Roy; Watkins, Peter; Watson, Alan; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Anthony; Waugh, Ben; Weber, Marc; Weber, Manuel; Weber, Michele; Weber, Pavel; Weidberg, Anthony; Weingarten, Jens; Weiser, Christian; Wellenstein, Hermann; Wells, Phillippa; Wenaus, Torre; Wendler, Shanti; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Werth, Michael; Werthenbach, Ulrich; Wessels, Martin; Whalen, Kathleen; White, Andrew; White, Martin; White, Sebastian; Whitehead, Samuel Robert; Whiteson, Daniel; Whittington, Denver; Wicek, Francois; Wicke, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik, Liv Antje Mari; Wildauer, Andreas; Wildt, Martin Andre; Wilkens, Henric George; Williams, Eric; Williams, Hugh; Willocq, Stephane; Wilson, John; Wilson, Michael Galante; Wilson, Alan; Wingerter-Seez, Isabelle; Winklmeier, Frank; Wittgen, Matthias; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wraight, Kenneth; Wright, Catherine; Wright, Dennis; Wrona, Bozydar; Wu, Sau Lan; Wu, Xin; Wulf, Evan; Wynne, Benjamin; Xaplanteris, Leonidas; Xella, Stefania; Xie, Song; Xu, Da; Xu, Neng; Yamada, Miho; Yamamoto, Akira; Yamamoto, Kyoko; Yamamoto, Shimpei; Yamamura, Taiki; Yamaoka, Jared; Yamazaki, Takayuki; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Un-Ki; Yang, Zhaoyu; Yao, Weiming; Yao, Yushu; Yasu, Yoshiji; Ye, Jingbo; Ye, Shuwei; Yilmaz, Metin; Yoosoofmiya, Reza; Yorita, Kohei; Yoshida, Riktura; Young, Charles; Youssef, Saul; Yu, Dantong; Yu, Jaehoon; Yuan, Li; Yurkewicz, Adam; Zaidan, Remi; Zaitsev, Alexander; Zajacova, Zuzana; Zambrano, Valentina; Zanello, Lucia; Zaytsev, Alexander; Zeitnitz, Christian; Zeller, Michael; Zemla, Andrzej; Zendler, Carolin; Zenin, Oleg; Zenis, Tibor; Zenonos, Zenonas; Zenz, Seth; Zerwas, Dirk; Zevi della Porta, Giovanni; Zhan, Zhichao; Zhang, Huaqiao; Zhang, Jinlong; Zhang, Qizhi; Zhang, Xueyao; Zhao, Long; Zhao, Tianchi; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Ning; Zhou, Yue; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Yingchun; Zhuang, Xuai; Zhuravlov, Vadym; Zimmermann, Robert; Zimmermann, Simone; Zimmermann, Stephanie; Ziolkowski, Michael; Zivkovic, Lidija; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zutshi, Vishnu

    2010-01-01

    The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\\mu}m and a relative momentum resolution {\\sigma}p/p = (4.83+/-0.16)...

  2. CALET On-orbit Calibration and Performance

    Science.gov (United States)

    Akaike, Yosui; Calet Collaboration

    2017-01-01

    The CALorimetric Electron Telescope (CALET) was installed on the International Space Station (ISS) in August 2015, and has been accumulating high-statistics data to perform high-precision measurements of cosmic ray electrons, nuclei and gamma-rays. CALET has an imaging and a fully active calorimeter, with a total thickness of 30 radiation lengths and 1.3 proton interaction lengths, that allow measurements well into the TeV energy region with excellent energy resolution, 2% for electrons above 100 GeV, and powerful particle identification. CALET's performance has been confirmed by Monte Carlo simulations and beam tests. In order to maximize the detector performance and keep the high resolution for long observation on the ISS, it is required to perform the precise calibration of each detector component. We have therefore evaluated the detector response and monitored it by using penetrating cosmic ray events such as protons and helium nuclei. In this paper, we will present the on-orbit calibration and detector performance of CALET on the ISS. This research was supported by JSPS postdoctral fellowships for research abroad.

  3. Novel calibration system with sparse wires for CMB polarization receivers

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, O.; /KEK, Tsukuba /Chicago U., KICP; Nguyen, H.; /Fermilab; Bischoff, C.; /Chicago U., KICP /Harvard-Smithsonian Ctr. Astrophys.; Brizius, A.; Buder, I.; Kusaka, A. /Chicago U., KICP

    2011-07-01

    B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

  4. Novel calibration system with sparse wires for CMB polarization receivers

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, O.; /KEK, Tsukuba /Chicago U., KICP; Nguyen, H.; /Fermilab; Bischoff, C.; /Chicago U., KICP /Harvard-Smithsonian Ctr. Astrophys.; Brizius, A.; Buder, I.; Kusaka, A. /Chicago U., KICP

    2011-07-01

    B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

  5. Bayesian Calibration of Microsimulation Models.

    Science.gov (United States)

    Rutter, Carolyn M; Miglioretti, Diana L; Savarino, James E

    2009-12-01

    Microsimulation models that describe disease processes synthesize information from multiple sources and can be used to estimate the effects of screening and treatment on cancer incidence and mortality at a population level. These models are characterized by simulation of individual event histories for an idealized population of interest. Microsimulation models are complex and invariably include parameters that are not well informed by existing data. Therefore, a key component of model development is the choice of parameter values. Microsimulation model parameter values are selected to reproduce expected or known results though the process of model calibration. Calibration may be done by perturbing model parameters one at a time or by using a search algorithm. As an alternative, we propose a Bayesian method to calibrate microsimulation models that uses Markov chain Monte Carlo. We show that this approach converges to the target distribution and use a simulation study to demonstrate its finite-sample performance. Although computationally intensive, this approach has several advantages over previously proposed methods, including the use of statistical criteria to select parameter values, simultaneous calibration of multiple parameters to multiple data sources, incorporation of information via prior distributions, description of parameter identifiability, and the ability to obtain interval estimates of model parameters. We develop a microsimulation model for colorectal cancer and use our proposed method to calibrate model parameters. The microsimulation model provides a good fit to the calibration data. We find evidence that some parameters are identified primarily through prior distributions. Our results underscore the need to incorporate multiple sources of variability (i.e., due to calibration data, unknown parameters, and estimated parameters and predicted values) when calibrating and applying microsimulation models.

  6. Pressures Detector Calibration and Measurement

    CERN Document Server

    AUTHOR|(CDS)2156315

    2016-01-01

    This is report of my first and second projects (of 3) in NA61. I did data taking and analysis in order to do calibration of pressure detectors and verified it. I analyzed the data by ROOT software using the C ++ programming language. The first part of my project was determination of calibration factor of pressure sensors. Based on that result, I examined the relation between pressure drop, gas flow rate of in paper filter and its diameter.

  7. UVIS G280 Flux Calibration

    Science.gov (United States)

    Bushouse, Howard

    2009-07-01

    Flux calibration, image displacement, and spectral trace of the UVIS G280 grism will be established using observations of the HST flux standard start GD71. Accompanying direct exposures will provide the image displacement measurements and wavelength zeropoints for dispersed exposures. The calibrations will be obtained at the central position of each CCD chip and at the center of the UVIS field. No additional field-dependent variations will be derived.

  8. Infrasound Sensor Calibration and Response

    Science.gov (United States)

    2012-09-01

    functions with faster rise times. SUMMARY We have documented past work on the determination of the calibration constant of the LANL infrasound sensor...Monitoring Technologies 735 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the collection of information is estimated...National Laboratory ( LANL ) has operated an infrasound sensor calibration chamber that operates over a frequency range of 0.02 to 4 Hz. This chamber has

  9. Beam Imaging and Luminosity Calibration

    CERN Document Server

    Klute, Markus; Salfeld-Nebgen, Jakob

    2016-01-01

    We discuss a method to reconstruct two-dimensional proton bunch densities using vertex distributions accumulated during LHC beam-beam scans. The $x$-$y$ correlations in the beam shapes are studied and an alternative luminosity calibration technique is introduced. We demonstrate the method on simulated beam-beam scans and estimate the uncertainty on the luminosity calibration associated to the beam-shape reconstruction to be below 1\\%.

  10. Calibración de un sistema electrónico para la caracterización óptica de diodos emisores de luz

    OpenAIRE

    Vara Lubiano, Mónica

    2017-01-01

    El objetivo de este trabajo es la calibración de un sistema electrónico capaz de automatizar la obtención de espectros de emisión de fuentes de luz. Se trata de obtener una medida de la irradiancia de la fuente, es decir, potencia suministrada por la misma por unidad de superficie y para cada longitud de onda. En primer lugar se calibró la medida de la longitud de onda. Éste proceso consistió en la comparaci ón directa del espectro obtenido por el sistema con el valor conocido ...

  11. Steady State Vacuum Ultraviolet Exposure Facility With Automated Calibration Capability

    Science.gov (United States)

    Stueber, Thomas J.; Sechkar, Edward A.; Dever, Joyce A.; Banks, Bruce A.

    2000-01-01

    NASA Glenn Research Center at Lewis Field designed and developed a steady state vacuum ultraviolet automated (SSVUVa) facility with in situ VUV intensity calibration capability. The automated feature enables a constant accelerated VUV radiation exposure over long periods of testing without breaking vacuum. This test facility is designed to simultaneously accommodate four isolated radiation exposure tests within the SSVUVa vacuum chamber. Computer-control of the facility for long, term continuous operation also provides control and recording of thermocouple temperatures, periodic recording of VUV lamp intensity, and monitoring of vacuum facility status. This paper discusses the design and capabilities of the SSVUVa facility.

  12. Experimental Results of Site Calibration and Sensitivity Measurements in OTR for UWB Systems

    Science.gov (United States)

    Viswanadham, Chandana; Rao, P. Mallikrajuna

    2016-08-01

    System calibration and parameter accuracy measurement of electronic support measures (ESM) systems is a major activity, carried out by electronic warfare (EW) engineers. These activities are very critical and needs good understanding in the field of microwaves, antennas, wave propagation, digital and communication domains. EW systems are broad band, built with state-of-the art electronic hardware, installed on different varieties of military platforms to guard country's security from time to time. EW systems operate in wide frequency ranges, typically in the order of thousands of MHz, hence these are ultra wide band (UWB) systems. Few calibration activities are carried within the system and in the test sites, to meet the accuracies of final specifications. After calibration, parameters are measured for their accuracies either in feed mode by injecting the RF signals into the front end or in radiation mode by transmitting the RF signals on to system antenna. To carry out these activities in radiation mode, a calibrated open test range (OTR) is necessary in the frequency band of interest. Thus site calibration of OTR is necessary to be carried out before taking up system calibration and parameter measurements. This paper presents the experimental results of OTR site calibration and sensitivity measurements of UWB systems in radiation mode.

  13. Calibration of shaft alignment instruments

    Science.gov (United States)

    Hemming, Bjorn

    1998-09-01

    Correct shaft alignment is vital for most rotating machines. Several shaft alignment instruments, ranging form dial indicator based to laser based, are commercially available. At VTT Manufacturing Technology a device for calibration of shaft alignment instruments was developed during 1997. A feature of the developed device is the similarity to the typical use of shaft alignment instruments i.e. the rotation of two shafts during the calibration. The benefit of the rotation is that all errors of the shaft alignment instrument, for example the deformations of the suspension bars, are included. However, the rotation increases significantly the uncertainty of calibration because of errors in the suspension of the shafts in the developed device for calibration of shaft alignment instruments. Without rotation the uncertainty of calibration is 0.001 mm for the parallel offset scale and 0,003 mm/m for the angular scale. With rotation the uncertainty of calibration is 0.002 mm for the scale and 0.004 mm/m for the angular scale.

  14. Calibration of the EPD sensors on Solar Orbiter

    Science.gov (United States)

    Wimmer-Schweingruber, Robert; Mason, Glenn; Ho, George; Boettcher, Stephan; Martin, Cesar; Kulkarni, Shrinivasrao; Sanchez Prieto, Sebastian; Rodriguez-Pacheco, Javier; Prieto, Manuel; Panitzsch, Lauri

    2016-07-01

    The Energetic Particle Detector (EPD) on Solar Orbiter will measure ions from a few keV/nuc up to hundred(s) of MeV/nuc (ion specific) and electrons from few keV to ~20 MeV to understand how solar eruptions produce energetic particle radiation that fills the heliosphere. This important question is one of the main scientific objectives of Solar Orbiter. The EPD sensors have undergone substantial calibration efforts which we will report in this presentation.

  15. Measurement of small antenna reflector losses for radiometer calibration budget

    OpenAIRE

    Skou, Niels

    1997-01-01

    Antenna reflector losses play an important role in the calibration budget for a microwave radiometer. If the losses are small, they are difficult to measure by traditional means. However, they can be assessed directly by radiometric means using the sky brightness temperature as incident radiation. This paper describes how such measurements are carried out as well as a suitable experimental setup. The main reflector of the European Space Agency's MIMR system is used to demonstrate the principle

  16. Psiconeuroinmunología: Conexiones entre sistema nervioso y sistema inmune

    Directory of Open Access Journals (Sweden)

    García López, Luis Joaquín

    2008-09-01

    Full Text Available La psiconeuroinmunología es una nueva parcela de la ciencia que apenas lleva tres décadas, pero que en los últimos años ha sido objeto de una enorme atención por diversos grupos de investigación. El articulo pretende exponer brevemente cómo están organizados los sistemas inmune y neuroendocrino, para después presentar los hallazgos que hasta el momento intentan dar explicación de las relaciones entre ambos con el sistema nervioso, así como las influencias de unos sobre otros, más concretamente expresar la relación entre los tres sistemas responsables de la defensa del organismo y, más ampliamente, de su mantenimiento homeostático. Cuando se trata de amenazas, el sistema nervioso central tiene que decidir qué sistema se pone en marcha, el sistema de estrés como energía para el ataque o la huida (un animal que nos quiere atacar, el sistema inmune para neutralizar el antígeno (un virus que nos quiere atacar o ambos (la energía es necesaria también para el sistema inmune. Como parece ser que en muchas ocasiones la depresión aparece tras los esfuerzos infructuosos de puesta en marcha de estrategias de afrontamiento, también hemos repasado sucintamente algunas investigaciones que relacionan al sistema inmune con la depresión, así como con los trastornos del sueño. Se finaliza con las aportaciones que la psicología puede ofrecer a nivel terapéutico.

  17. Solar and infrared radiation measurements

    CERN Document Server

    Vignola, Frank; Michalsky, Joseph

    2012-01-01

    The rather specialized field of solar and infrared radiation measurement has become more and more important in the face of growing demands by the renewable energy and climate change research communities for data that are more accurate and have increased temporal and spatial resolution. Updating decades of acquired knowledge in the field, Solar and Infrared Radiation Measurements details the strengths and weaknesses of instruments used to conduct such solar and infrared radiation measurements. Topics covered include: Radiometer design and performance Equipment calibration, installation, operati

  18. Sistema de salud de México

    OpenAIRE

    Octavio Gómez Dantés; Sergio Sesma; Victor M. Becerril; Felicia M. Knaul; Héctor Arreola; Julio Frenk

    2011-01-01

    En este trabajo se describe el sistema mexicano de salud. En la primera parte se discuten las condiciones de salud de la población mexicana, con énfasis en los padecimientos emergentes que constituyen las principales causas de muerte, diabetes, enfermedades isquémicas del corazón, padecimientos cerebrovasculares y cáncer. En la segunda parte se describe la estructura básica del sistema, las instituciones que lo conforman, la población a la que cubre, los beneficios que reciben los afiliados d...

  19. Ortogonalidad y capacidad en sistemas MIMO masivo

    OpenAIRE

    Romero Ibáñez, Irene

    2014-01-01

    La tecnología MIMO constituye un antes y un después en los sistemas de comunicaciones inalámbricas. Esta tecnología ofrece multitud de beneficios que nos acercan a cumplir con los desafíos impuestos por las limitaciones en un canal inalámbrico así como por las restricciones de nuestros recursos o el espacio físico ocupado por las antenas, entre otros. Además de explotar tanto la dimensión temporal como la frecuencial en sistemas inalámbricos convencionales con una única antena, las posibilida...

  20. As unidades fundamentais do sistema internacional (SI)

    OpenAIRE

    2002-01-01

    Nos últimos anos de docência no Instituto Superior de Engenharia de Lisboa, redigimos, para uso dos alunos, um pequeno memorando sobre as unidades fundamentais do Sistema Internacional - as unidade de base -, tendo em vista, principalmente, a correção da escrita das ditas unidades, seus múltiplos e seus submúltiplos. Esse escasso conjunto de menos de meia dúzia de páginas foi sendo gradualmente alargado, de forma a incluir referência aos sistemas de unidades primitivos e sua evolução, como ta...

  1. Sistema de salud de Perú

    OpenAIRE

    2011-01-01

    En este trabajo se describen las condiciones generales de salud de la población peruana y, con mayor detalle, el sistema peruano de salud: su estructura y cobertura, sus fuentes de financiamiento, los recursos físicos, materiales y humanos con los que cuenta, y las actividades de rectoría que en él se desarrollan. Asimismo se discute el estado en el que se encuentran la generación de información y la investigación, y la participación de los ciudadanos en la gestión y evaluación del sistema. E...

  2. Algoritmos array para filtragem de sistemas lineares

    OpenAIRE

    Gildson Queiroz de Jesus

    2007-01-01

    Esta dissertação desenvolve filtro de informação, algoritmos array para estimador do erro médio mínimo quadrático para sistemas lineares sujeitos a saltos Markovianos e algoritmos array rápidos para filtragem de sistemas singulares convencionais. Exemplos numéricos serão apresentados para mostrarem as vantagens dos algoritmos array deduzidos. Parte dos resultados obtidos nesta pesquisa serão publicados no seguinte artigo: Terra et al. (2007). Terra, M. H., Ishihara, J. Y. and Jesus, G. Q. (20...

  3. Comprensión de sistemas paralelos

    OpenAIRE

    Perez, Norma; Berón, Mario; Henriques, Pedro; Pereira, Maria João

    2015-01-01

    Las Tecnologías de la Información y la Comunicación (TIC’s) ofrecen servicios sorprendentes, que proporcionan acceso permanente a todo tipo de información y aplicaciones que se encuentran alrededor del mundo. En particular, los sistemas paralelos son buenos ejemplos de los paradigmas emergentes que deben ser considerados por científicos que se desempeñan en el campo informático. Estos sistemas plantean actividades críticas (sincronización, comunicación, etc.) que repercuten en la efi...

  4. Caos e simetrias em sistemas quanticos

    OpenAIRE

    Righi, Assis Francisco Moro

    1989-01-01

    Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro de Ciencias Fisicas e Matematicas Neste trabalho são investigadas algumas propriedades espectrais de dois sistemas quânticos não separáveis: o hamiltoniano de Henon-Heiles e o oscilador harmônico bidimensional com perturbação sugerida por Pullen e Edmonds do tipo x2y2. Foi confirmado que estes sistemas apresentam uma transição do comportamento quântico regular para o comportamento quântico irregular, também chamado caó...

  5. Sistemas dinámicos planos

    OpenAIRE

    Torres Henao, Jorge Alberto

    2013-01-01

    Resumen: En el documento se hace una presentación de los sistemas dinámicos planos, en particular los continuos provenientes de ecuaciones diferenciales ordinarias de segundo orden o de sistemas de ecuaciones diferenciales simultáneas de primer orden. Se introduce la teoría con ejemplos cuidadosamente seleccionados que hacen especial énfasis en las propiedades tipológicas de las soluciones y se dedica toda una sección a la obtención de una demostración del Teorema de Poincaré-Bendixson. La pa...

  6. El Derecho Administrativo del Sistema Comunitario Andino

    Directory of Open Access Journals (Sweden)

    Jorge Enrique Santos Rodríguez

    2013-12-01

    Full Text Available Una de las tendencias contemporáneas del Derecho Administrativo es el reconocimiento de su existencia más allá de las fronteras de un Estado. Bajo esa premisa, se busca demostrar que en la Comunidad Andina de Naciones se configuran los elementos suficientes para afirmar que existe un Derecho Administrativo Comunitario Andino, en la medida en que de las normas andinas se desprende la existencia de una función administrativa andina, una organización administrativa al seno del Sistema Andino de Integración, un sistema de fuentes administrativas andina y un contencioso administrativo comunitario.

  7. Herramientas de simulacion para sistemas fotovoltaicos en ingenieria

    National Research Council Canada - National Science Library

    Silvestre, S; Castaner, L; D. Guasch

    2008-01-01

    Este trabajo presenta la simulacion de un sistema fotovoltaico, basado en el entorno abierto de programacion Matlab/Simulink, utilizado en la asignatura Sistemas Fotovoltaicos, dictado en un programa...

  8. Modelos exactamente solubles en mecanica estadistica de sistemas de Coulomb

    National Research Council Canada - National Science Library

    Tellez, Gabriel

    2013-01-01

    Se presenta una revision de modelos exactamente solubles de fisica estadistica clasica en dos dimensiones de sistemas de Coulomb, que son sistemas compuestos por un gran numero de particulas cargadas electricamente...

  9. El sistema linfático: el gran olvidado del sistema circulatorio.

    OpenAIRE

    Olmos Martínez, Susana; Gavidia Catalán, Valentín

    2014-01-01

    En el presente artículo se analizan los modelos mentales y las concepciones alternativas que tienen los estudiantes de distintos niveles educativos sobre el sistema linfático como componente del sistema circulatorio. Se establece una relación con las dificultades que se salvaron a lo largo de la historia en la adquisición de dichos conocimientos. Los resultados muestran una deficiente relación entre los sistemas linfáticos y sanguíneos, una falta de conocimientos tanto anatómicos como fisioló...

  10. El sistema linfático: el gran olvidado del sistema circulatorio

    OpenAIRE

    2014-01-01

    En el presente artículo se analizan los modelos mentales y las concepciones alternativas que tienen los estudiantes de distintos niveles educativos sobre el sistema linfático como componente del sistema circulatorio. Se establece una relación con las dificultades que se salvaron a lo largo de la historia en la adquisición de dichos conocimientos. Los resultados muestran una deficiente relación entre los sistemas linfáticos y sanguíneos, una falta de conocimientos tanto anatómicos ...

  11. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  12. NOAA Climate Data Record (CDR) of Intersatellite Calibrated Clear-Sky HIRS Channel 12 Brightness Temperature, Version 2.6

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This NOAA Climate Data Record (CDR) of Inter-Satellite Calibrated Clear-Sky High Resolution Infrared Radiation Sounder (HIRS) Channel 12 brightness temperatures...

  13. Calibration methodology and performance characterization of a polarimetric hyperspectral imager

    Science.gov (United States)

    Holder, Joel G.; Martin, Jacob A.; Pitz, Jeremey; Pezzaniti, Joseph L.; Gross, Kevin C.

    2014-05-01

    Polarimetric hyperspectral imaging (P-HSI) has the potential to improve target detection, material identification, and background characterization over conventional hyperspectral imaging and polarimetric imaging. To fully exploit the spectro-polarimetric signatures captured by such an instrument, a careful calibration process is required to remove the spectrally- and polarimetrically-dependent system response (gain). Calibration of instruments operating in the long-wave infrared (LWIR, 8μm to 12 μm) is further complicated by the polarized spectral radiation generated within the instrument (offset). This paper presents a calibration methodology developed for a LWIR Telops Hyper-Cam modified for polarimetry by replacing the entrance window with a rotatable holographic wire-grid polarizer (4000 line/mm, ZnSe substrate, 350:1 extinction ratio). A standard Fourier-transform spectrometer (FTS) spectro-radiometric calibration is modified to include a Mueller-matrix approach to account for polarized transmission through and polarized selfemission from each optical interface. It is demonstrated that under the ideal polarizer assumption, two distinct blackbody measurements at polarizer angles of 0°, 45°, 90°, and 135° are sufficient to calibrate the system for apparent degree-of-linear-polarization (DoLP) measurements. Noise-equivalent s1, s2, and DoLP are quantified using a wide-area blackbody. A polarization-state generator is used to determine the Mueller deviation matrix. Finally, a realistic scene involving buildings, cars, sky radiance, and natural vegetation is presented.

  14. Calibration of a slimehole density sonde using MCNPX

    Science.gov (United States)

    Won, Byeongho; Hwang, Seho; Shin, Jehyun; Kim, Jongman

    2014-05-01

    The density log is a well logging tool that can continuously record bulk density of the formation. This is widely applied for a variety of fields such as the petroleum exploitation, mineral exploration, and geotechnical survey and so on. The density log is normally applied to open holes. But there are frequently difficult conditions such as cased boreholes, the variation of borehole diameter, the borehole fluid salinity, and the stand-off and so on. So we need a density correction curves for the various borehole conditions. The primary calibration curve by manufacturer is used for the formation density calculation. In case of density log used for the oil industry, the calibration curves for various borehole environments are applied to the density correction, but commonly used slim-hole density logging sonde normally have a calibration curve for the variation of borehole diameter. In order to correct the various borehole environmental conditions, it is necessary to make the primary calibration curve of density sonde using numerical modeling. Numerical modeling serves as a low-cost substitute for experimental test pits. We have performed numerical modeling using the MCNP based on Monte-Carlo methods can record average behaviors of radiation particles. In this study, the work for matching the primary calibration curve of FDGS (Formation Density Gamma Sonde) for slime borehole with a 100 mCi 137 Cs gamma source was performed. On the basis of this work, correction curves in various borehole environments were produced.

  15. Energy calibration of CALET onboard the International Space Station

    Science.gov (United States)

    Asaoka, Y.; Akaike, Y.; Komiya, Y.; Miyata, R.; Torii, S.; Adriani, O.; Asano, K.; Bagliesi, M. G.; Bigongiari, G.; Binns, W. R.; Bonechi, S.; Bongi, M.; Brogi, P.; Buckley, J. H.; Cannady, N.; Castellini, G.; Checchia, C.; Cherry, M. L.; Collazuol, G.; Di Felice, V.; Ebisawa, K.; Fuke, H.; Guzik, T. G.; Hams, T.; Hareyama, M.; Hasebe, N.; Hibino, K.; Ichimura, M.; Ioka, K.; Ishizaki, W.; Israel, M. H.; Javaid, A.; Kasahara, K.; Kataoka, J.; Kataoka, R.; Katayose, Y.; Kato, C.; Kawanaka, N.; Kawakubo, Y.; Kitamura, H.; Krawczynski, H. S.; Krizmanic, J. F.; Kuramata, S.; Lomtadze, T.; Maestro, P.; Marrocchesi, P. S.; Messineo, A. M.; Mitchell, J. W.; Miyake, S.; Mizutani, K.; Moiseev, A. A.; Mori, K.; Mori, M.; Mori, N.; Motz, H. M.; Munakata, K.; Murakami, H.; Nakagawa, Y. E.; Nakahira, S.; Nishimura, J.; Okuno, S.; Ormes, J. F.; Ozawa, S.; Pacini, L.; Palma, F.; Papini, P.; Penacchioni, A. V.; Rauch, B. F.; Ricciarini, S.; Sakai, K.; Sakamoto, T.; Sasaki, M.; Shimizu, Y.; Shiomi, A.; Sparvoli, R.; Spillantini, P.; Stolzi, F.; Takahashi, I.; Takayanagi, M.; Takita, M.; Tamura, T.; Tateyama, N.; Terasawa, T.; Tomida, H.; Tsunesada, Y.; Uchihori, Y.; Ueno, S.; Vannuccini, E.; Wefel, J. P.; Yamaoka, K.; Yanagita, S.; Yoshida, A.; Yoshida, K.; Yuda, T.

    2017-05-01

    In August 2015, the CALorimetric Electron Telescope (CALET), designed for long exposure observations of high energy cosmic rays, docked with the International Space Station (ISS) and shortly thereafter began to collect data. CALET will measure the cosmic ray electron spectrum over the energy range of 1 GeV to 20 TeV with a very high resolution of 2% above 100 GeV, based on a dedicated instrument incorporating an exceptionally thick 30 radiation-length calorimeter with both total absorption and imaging (TASC and IMC) units. Each TASC readout channel must be carefully calibrated over the extremely wide dynamic range of CALET that spans six orders of magnitude in order to obtain a degree of calibration accuracy matching the resolution of energy measurements. These calibrations consist of calculating the conversion factors between ADC units and energy deposits, ensuring linearity over each gain range, and providing a seamless transition between neighboring gain ranges. This paper describes these calibration methods in detail, along with the resulting data and associated accuracies. The results presented in this paper show that a sufficient accuracy was achieved for the calibrations of each channel in order to obtain a suitable resolution over the entire dynamic range of the electron spectrum measurement.

  16. Calibration of the CMS Electromagnetic Calorimeter with LHC collision data

    CERN Document Server

    Obertino, Margherita Maria

    2012-01-01

    The CMS ECAL is one of the highest resolution electromagnetic calorimeters ever constructed, but relies upon precision calibration in order to achieve and maintain its design performance. Variations in light collected from the lead tungstate crystals, due to intrinsic differences in crystals/photodetectors, as well as variations with time due to radiation damage for example, need to be taken into account. Sophisticated and effective methods of inter-crystal and absolute calibration have been devised, using collision data from the 2011 LHC run and a dedicated light injection system. For inter-calibration, low mass particle decays ($\\pi^0$ and $\\eta$) to two photons are exploited, as well as the azimuthal symmetry of the average energy deposition at a given pseudorapidity. Absolute calibration has been performed using Z decays into electron-positron pairs. The light injection system monitors the channel response in real-time and enables the re-calibration of the measured energies over time. This is cross-checke...

  17. On the absolute calibration of SO2 cameras

    Directory of Open Access Journals (Sweden)

    J. Zielcke

    2012-09-01

    Full Text Available Sulphur dioxide emission flux measurements are an important tool for volcanic monitoring and eruption risk assessment. The SO2 camera technique remotely measures volcanic emissions by analysing the ultraviolet absorption of SO2 in a narrow spectral window between 305 nm and 320 nm using solar radiation scattered in the atmosphere. The SO2 absorption is selectively detected by mounting band-pass interference filters in front of a two-dimensional, UV-sensitive CCD detector. While this approach is simple and delivers valuable insights into the two-dimensional SO2 distribution, absolute calibration has proven to be difficult. An accurate calibration of the SO2 camera (i.e., conversion from optical density to SO2 column density, CD is crucial to obtain correct SO2 CDs and flux measurements that are comparable to other measurement techniques and can be used for volcanological applications. The most common approach for calibrating SO2 camera measurements is based on inserting quartz cells (cuvettes containing known amounts of SO2 into the light path. It has been found, however, that reflections from the windows of the calibration cell can considerably affect the signal measured by the camera. Another possibility for calibration relies on performing simultaneous measurements in a small area of the camera's field-of-view (FOV by a narrow-field-of-view Differential Optical Absorption Spectroscopy (NFOV-DOAS system. This procedure combines the very good spatial and temporal resolution of the SO2 camera technique with the more accurate column densities obtainable from DOAS measurements. This work investigates the uncertainty of results gained through the two commonly used, but quite different calibration methods (DOAS and calibration cells. Measurements with three different instruments, an SO2 camera, a NFOV-DOAS system and an Imaging DOAS (IDOAS, are presented. We compare the calibration-cell approach with the calibration from the NFOV-DOAS system. The

  18. Estabilización robusta de sistemas lineales

    Directory of Open Access Journals (Sweden)

    Horacio Leyva Castellanos

    2013-12-01

    Full Text Available En este trabajo se muestra un conjunto de resultados que permiten abordar el problema de la estabilización robusta de una familia de sistemas lineales positivos. Se describen dos nuevas aplicaciones en la teoría de control positivo para sistemas compartimentales y se muestra la aplicación de un teorema de robustez para tales sistemas

  19. Sistemas territoriales de salud frente al sistema general de seguridad social en salud de Colombia

    OpenAIRE

    2014-01-01

    Introducción: El artículo expone los elementos y fundamentos que podrían avalar la generación de sistemas de seguridad social en salud territorial, en complementación con el sistema general preexistente. Materiales y Métodos: La eclosión generalizada en los sistemas de salud, implica la revisión de los modelos propuestos de carácter central y territorial. El análisis económico institucional, permite analizar las condiciones que tienen los sistemas generales para impactar en los esquemas terri...

  20. Radiation Therapy

    Science.gov (United States)

    Radiation therapy is a cancer treatment. It uses high doses of radiation to kill cancer cells and stop them from ... half of all cancer patients receive it. The radiation may be external, from special machines, or internal, ...

  1. El Sistema and American Music Education

    Science.gov (United States)

    Lesniak, Melissa

    2012-01-01

    The brainchild of Jose Antonio Abreu, El Sistema, a music education program for aspiring orchestra musicians launched in Venezuela for students of limited means and now spreading to other parts of the world, has become a subject of interest to music teachers and teacher educators in North America. This article examines a bit of the program's…

  2. El Sistema and American Music Education

    Science.gov (United States)

    Lesniak, Melissa

    2012-01-01

    The brainchild of Jose Antonio Abreu, El Sistema, a music education program for aspiring orchestra musicians launched in Venezuela for students of limited means and now spreading to other parts of the world, has become a subject of interest to music teachers and teacher educators in North America. This article examines a bit of the program's…

  3. Elementos del sistema electoral del Congreso Mexicano

    Directory of Open Access Journals (Sweden)

    Aldo Medina García

    2013-08-01

    Full Text Available El presente artículo es un estudio de los componentes del sistema electoral, diseñado por el legislador mexicano para integrar al parlamento federal. Estudio desarrollado a sabiendas de la importancia que reviste el sistema electoral como un medio que permite a los ciudadanos convertir su voto expresado en las urnas en escaños a favor de determinado candidato o partido. En dicho análisis tomamos en cuenta la evolución constitucional del sistema electoral mexicano, la participación de las fuerzas minoritarias en la integración del Senado y de la Cámara de Diputados, la división que se hace del territorio en circunscripciones electorales, la barrera electoral que se fija a los partidos políticos para acceder a la representación en el Parlamento, la fórmula de asignación que se aplica a la votación obtenida, para finalmente concluir que el sistema electoral mexicano es esencialmente mayoritario aun cuando se vista de proporcional.

  4. Sistema de Reinscripciones Vía Internet

    Directory of Open Access Journals (Sweden)

    Bertha Alicia Góngora Serna

    2005-01-01

    Full Text Available Este Proyecto se enfoca al diseño de una página Web para optimizar el sistema de reinscripciones del Instituto Tecnológico de Aguascalientes (ITA, la cual permite que los alumnos utilicen menos tiempo en el proceso de inscripción, además de facilitar que dicha actividad se pueda realizar desde su hogar. Para la elaboración de este proyecto se requirió de Tecnologías web como HTML, JavaScript y JSP. La información necesaria fue reutilizada de los datos que actualmente genera el sistema de reinscripciones. La investigación que se llevó a cabo para sustentar este proyecto indaga desde la historia del Internet, una explicación breve de las tecnologías Web requeridas, algunos sistemas de reinscripciones de diferentes escuelas de nivel superior del país, así como el funcionamiento básico del sistema actual de reinscripciones del ITA

  5. Elementos del sistema electoral del Congreso Mexicano

    Directory of Open Access Journals (Sweden)

    Aldo Medina García

    2013-07-01

    Full Text Available El presente artículo es un estudio de los componentes del sistema electoral, diseñado por el legislador mexicano para integrar al parlamento federal. Estudio desarrollado a sabiendas de la importancia que reviste el sistema electoral como un medio que permite a los ciudadanos convertir su voto expresado en las urnas en escaños a favor de determinado candidato o partido. En dicho análisis tomamos en cuenta la evolución constitucional del sistema electoral mexicano, la participación de las fuerzas minoritarias en la integración del Senado y de la Cámara de Diputados, la división que se hace del territorio en circunscripciones electorales, la barrera electoral que se fija a los partidos políticos para acceder a la representación en el Parlamento, la fórmula de asignación que se aplica a la votación obtenida, para finalmente concluir que el sistema electoral mexicano es esencialmente mayoritario aun cuando se vista de proporcional.

  6. ENEA presenta sistema ADS per trattamento scorie

    CERN Multimedia

    2002-01-01

    "Arriva il sistema Ads (Accelerator driven system) per il trattamento dei rifiuti radioattivi. Lo studio di fattibilita' per l' innovativa tecnologia, realizzato da un gruppo di lavoro congiunto Enea, Cea, Cern e Ansaldo, e' stato presentato oggi nel corso di un workshop presieduto dal premio Nobel per la fisica, Carlo Rubbia" (1/2 page).

  7. Hacia un sistema de indicadores sociales

    OpenAIRE

    Rob Vos

    1996-01-01

    El presente documento propone un Sistema de Indicadores Sociales (SIS) que facilite el análisis de las dimensiones, naturaleza y causas de la pobreza y desigualdad en América Latina y la vigilancia y monitoreo del impacto de las políticas económicas y sociales.

  8. Calibration of the SNO+ experiment

    Science.gov (United States)

    Maneira, J.; Falk, E.; Leming, E.; Peeters, S.; SNO+ collaboration.

    2017-09-01

    The main goal of the SNO+ experiment is to perform a low-background and high-isotope-mass search for neutrinoless double-beta decay, employing 780 tonnes of liquid scintillator loaded with tellurium, in its initial phase at 0.5% by mass for a total mass of 1330 kg of 130Te. The SNO+ physics program includes also measurements of geo- and reactor neutrinos, supernova and solar neutrinos. Calibrations are an essential component of the SNO+ data-taking and analysis plan. The achievement of the physics goals requires both an extensive and regular calibration. This serves several goals: the measurement of several detector parameters, the validation of the simulation model and the constraint of systematic uncertainties on the reconstruction and particle identification algorithms. SNO+ faces stringent radiopurity requirements which, in turn, largely determine the materials selection, sealing and overall design of both the sources and deployment systems. In fact, to avoid frequent access to the inner volume of the detector, several permanent optical calibration systems have been developed and installed outside that volume. At the same time, the calibration source internal deployment system was re-designed as a fully sealed system, with more stringent material selection, but following the same working principle as the system used in SNO. This poster described the overall SNO+ calibration strategy, discussed the several new and innovative sources, both optical and radioactive, and covered the developments on source deployment systems.

  9. The KLOE Online Calibration System

    Institute of Scientific and Technical Information of China (English)

    E.Pasqualucci

    2001-01-01

    Based on all the features of the KLOE online software,the online calibration system performs current calibration quality checking in real time and starts automatically new calibration procedures when needed.Acalibration manager process controls the system,implementing the interface to the online system,receiving information from the run control and translating its state transitions to a separate state machine.It acts as a " calibration run controller"and performs failure recovery when requested by a set of process checkers.The core of the system is a multi-threaded OO histogram server that receives histogramming commands by remote processes and operates on local ROOT histograms.A client library and C,fortran and C++ application interface libraries allow the user to connect and define his own histogram or read histograms owned by others using an bool-like interface.Several calibration processes running in parallel in a destributed,multiplatform environment can fill the same histograms,allowing fast external information check.A monitor thread allow remote browsing for visual inspection,Pre-filtered data are read in nonprivileged spy mode from the data acquisition system via the Kloe Integrated Dataflow,privileged spy mode from the data acquisiton system via the Kole Integrated Dataflow.The main characteristics of the system are presented.

  10. Sistemas ultrasónicos para la irrigación del sistema de conductos radiculares

    Directory of Open Access Journals (Sweden)

    A. García Delgado

    2014-04-01

    Full Text Available La eliminación de los restos de tejido pulpar vital y necrótico y de los microorganismos del sistema de conductos radiculares, es esencial para el éxito en endodoncia. La desinfección del canal radicular mediante la irrigación e instrumentación es el factor más importante en la prevención y tratamiento de la periodontitis apical. Al ser imposible con la instrumentación llegar a todas las áreas del sistema de conductos, la irrigación cobra especial importancia. Por este motivo, en la última década se han desarrollado una serie de sistemas de dispensación y agitación de irrigantes, tales como los ultrasonidos. En concreto, en este artículo de revisión se evalúa la información disponible de los diez últimos años sobre la efectividad de los sistemas ultrasónicos para eliminar bacterias, tejido pulpar, restos de dentina y barrillo dentinario, la capacidad de estos dispositivos para hacer que el irrigante penetre en el sistema de conductos radiculares y la seguridad en su uso. Los resultados de la revisión muestran que los sistemas ultrasónicos son más eficaces en el desbridamiento químico, biológico y físico del sistema de conductos radiculares que los sistemas de irrigación convencional, a la vez que son seguros.

  11. Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-11-21

    Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibration service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These

  12. On chromatic and geometrical calibration

    DEFF Research Database (Denmark)

    Folm-Hansen, Jørgen

    1999-01-01

    of non-uniformity of the illumination of the image plane. Only the image deforming aberrations and the non-uniformity of illumination are included in the calibration models. The topics of the pinhole camera model and the extension to the Direct Linear Transform (DLT) are described. It is shown how......The main subject of the present thesis is different methods for the geometrical and chromatic calibration of cameras in various environments. For the monochromatic issues of the calibration we present the acquisition of monochrome images, the classic monochrome aberrations and the various sources...... the DLT can be extended with non-linear models of the common lens aberrations/errors some of them caused by manufacturing defects like decentering and thin prism distortion. The relation between a warping and the non-linear defects are shown. The issue of making a good resampling of an image by using...

  13. Reduced Ambiguity Calibration for LOFAR

    CERN Document Server

    Yatawatta, Sarod

    2012-01-01

    Interferometric calibration always yields non unique solutions. It is therefore essential to remove these ambiguities before the solutions could be used in any further modeling of the sky, the instrument or propagation effects such as the ionosphere. We present a method for LOFAR calibration which does not yield a unitary ambiguity, especially under ionospheric distortions. We also present exact ambiguities we get in our solutions, in closed form. Casting this as an optimization problem, we also present conditions for this approach to work. The proposed method enables us to use the solutions obtained via calibration for further modeling of instrumental and propagation effects. We provide extensive simulation results on the performance of our method. Moreover, we also give cases where due to degeneracy, this method fails to perform as expected and in such cases, we suggest exploiting diversity in time, space and frequency.

  14. Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Faber, M.H.; Sørensen, John Dalsgaard

    2003-01-01

    The present paper addresses fundamental concepts of reliability based code calibration. First basic principles of structural reliability theory are introduced and it is shown how the results of FORM based reliability analysis may be related to partial safety factors and characteristic values....... Thereafter the code calibration problem is presented in its principal decision theoretical form and it is discussed how acceptable levels of failure probability (or target reliabilities) may be established. Furthermore suggested values for acceptable annual failure probabilities are given for ultimate...... and serviceability limit states. Finally the paper describes the Joint Committee on Structural Safety (JCSS) recommended procedure - CodeCal - for the practical implementation of reliability based code calibration of LRFD based design codes....

  15. Sistemas de Cultivo de la Papa en Antioquia

    Directory of Open Access Journals (Sweden)

    Arango U. Ernesto

    1948-04-01

    Full Text Available Existen tres sistemas de cultivo entre los que se encuentran el sistema de tapado, sistema de destapado y el sistema de cepillado. Es necesario aclarar que la mayor utilidad que se obtiene con el sistema de cepillado sobre el de destapado, no compensa las pérdidas del suelo, puesto que este queda inutilizado por mucho tiempo, siendo necesario abandonarlo por varios años, antes de volver a lograr una cosecha remuneradora. Además se obtienen cosechas de papa demasiado bajas lo que merma considerablemente los rendimientos de la zona.

  16. Generic methodology for calibrating profiling nacelle lidars

    DEFF Research Database (Denmark)

    Borraccino, Antoine; Courtney, Michael; Wagner, Rozenn

    is calibrated rather than a reconstructed parameter. This contribution presents a generic methodology to calibrate profiling nacelle-mounted lidars. The application of profiling lidars to wind turbine power performance and corresponding need for calibration procedures is introduced in relation to metrological...... standards. Further, two different calibration procedure concepts are described along with their strengths and weaknesses. The main steps of the generic methodology are then explained and illustrated by calibration results from two types of profiling lidars. Finally, measurement uncertainty assessment...

  17. Flexible calibration procedure for fringe projection profilometry

    OpenAIRE

    Vargas, Javier; Quiroga Mellado, Juan Antonio; Terrón López, María José

    2007-01-01

    A novel calibration method for whole field three-dimensional shape measurement by means of fringe projection is presented. Standard calibration techniques, polynomial-and model-based, have practical limitations such as the difficulty of measuring large fields of view, the need to use precise z stages, and bad calibration results due to inaccurate calibration points. The proposed calibration procedure is a mixture of the two main standard techniques, sharing their benefits and avoiding their m...

  18. The calibration of the solid state nuclear track detector LR 115 for radon measurements

    CERN Document Server

    Gericke, C; Jönsson, G; Freyer, K; Treutler, H C; Enge, W

    1999-01-01

    An experimental calibration of indoor room and outdoor soil detector devices which are based on LR 115 as sensitive element has taken place at the Swedish Radiation Protection Institute in Stockholm (Sweden) in 1994 and 1996, at the Physikalisch-Technischen Bundesanstalt in Braunschweig (Germany) in 1997 and at the Umweltforschungszentrum Leipzig-Halle (Germany) in 1997. Special properties of the used solid state nuclear track detector (SSNTD) material LR 115 have been measured to define the application of the experimental calibration.

  19. Gaia Data Release 1. Principles of the photometric calibration of the G band

    Science.gov (United States)

    Carrasco, J. M.; Evans, D. W.; Montegriffo, P.; Jordi, C.; van Leeuwen, F.; Riello, M.; Voss, H.; De Angeli, F.; Busso, G.; Fabricius, C.; Cacciari, C.; Weiler, M.; Pancino, E.; Brown, A. G. A.; Holland, G.; Burgess, P.; Osborne, P.; Altavilla, G.; Gebran, M.; Ragaini, S.; Galleti, S.; Cocozza, G.; Marinoni, S.; Bellazzini, M.; Bragaglia, A.; Federici, L.; Balaguer-Núñez, L.

    2016-11-01

    Context. Gaia is an ESA cornerstone mission launched on 19 December 2013 aiming to obtain the most complete and precise 3D map of our Galaxy by observing more than one billion sources. This paper is part of a series of documents explaining the data processing and its results for Gaia Data Release 1, focussing on the G band photometry. Aims: This paper describes the calibration model of the Gaia photometric passband for Gaia Data Release 1. Methods: The overall principle of splitting the process into internal and external calibrations is outlined. In the internal calibration, a self-consistent photometric system is generated. Then, the external calibration provides the link to the absolute photometric flux scales. Results: The Gaia photometric calibration pipeline explained here was applied to the first data release with good results. Details are given of the various calibration elements including the mathematical formulation of the models used and of the extraction and preparation of the required input parameters (e.g. colour terms). The external calibration in this first release provides the absolute zero point and photometric transformations from the Gaia G passband to other common photometric systems. Conclusions: This paper describes the photometric calibration implemented for the first Gaia data release and the instrumental effects taken into account. For this first release no aperture losses, radiation damage, and other second-order effects have not yet been implemented in the calibration.

  20. Tank calibration; Arqueacao de tanques

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Ana [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This work relates the analysis of the norms ISO (International Organization for Standardization) for calibration of vertical cylindrical tanks used in fiscal measurement, established on Joint Regulation no 1 of June 19, 2000 between the ANP (National Agency of Petroleum) and the INMETRO (National Institute of Metrology, Normalization and Industrial Quality). In this work a comparison between norms ISO and norms published by the API (American Petroleum Institute) and the IP (Institute of Petroleum) up to 2001 was made. It was concluded that norms ISO are wider than norms API, IP, and INMETRO methods in the calibration of vertical cylindrical tanks. (author)