WorldWideScience

Sample records for radiating divertor behavior

  1. A review of progress towards radiative divertor

    International Nuclear Information System (INIS)

    Zagorski, Roman

    1997-07-01

    A solution of the problem of the power and particle exhaust from the next step tokamaks, will require new techniques which redistribute the power entering the SOL onto much larger surface area than conventional divertor design permits, while maintaining good impurity retention in divertor volume and allowing for efficient helium pumping. Progress made in developing such techniques is discussed. Status of the modelling studies of dynamic gas target divertor and impurity seeded radiating divertors is presented. Recent results of experiments on radiative and gas target divertors are reviewed

  2. Divertor radiation in the ASDEX upgrade tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Sehmer, Till; Bernert, Matthias; Koll, Juergen; Meister, Hans; Wischmeier, Marco; Fantz, Ursel [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstrasse 2, 85748 Garching (Germany); Reimold, Felix [Forschungszentrum Juelich GmbH, Institut fuer Energie- und Klimaforschung - Plasmaphysik, 52425 Juelich (Germany); Collaboration: The ASDEX Upgrade Team

    2016-07-01

    To reduce in ITER the expected power flux density onto the divertor target, the plasma-wall interaction in the divertor needs to be strongly reduced. The fundamental path to achieve this is using radiation from seeded impurities, whereas the localization of this radiation (e.g. inside/outside confined region), which could have an impact onto the power balance, is a key challenge. The absolute radiated power distribution can be measured by foil bolometers. To study at the ASDEX Upgrade tungsten divertor the localization and quantification of radiation, the respective line of sight density of the bolometers has been improved by two additional cameras. The divertor radiation enhanced by nitrogen (N{sub 2}) seeding has been investigated, using variations of (1) the external heating power or (2) the N{sub 2} seeding rate. While in both cases the inner divertor stays fully detached, measurements indicate that the region of dominant radiation moves from the inner divertor through the X-Point into the confined region. In the outer divertor however, the measurements indicate either an immediate upwards shift or a continuous movement of the radiation away from the target, depending on experimental conditions.

  3. Engineering design of a radiative divertor for DIII-D

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Bozek, A.S.

    1995-10-01

    A new divertor configuration is being developed for the DIII-D tokamak. This divertor will operate in the radiative mode. Experiments and modeling form the basis for the new design. The Radiative Divertor reduces the heat flux on the divertor plates by dispersing the power with radiation in the divertor region. In addition, the Radiative Divertor structure will allow density control in plasma shapes required for advanced tokamak operation. The divertor structure allows for operation in either double-null or single-null plasma configurations. Four independently controlled divertor cryopumps will enable pumping at either the inboard (upper and lower) or the outboard (upper and lower) divertor plates. An upgrade to the DIII-D cryogenic system is part of this project. The increased capabilities of the cryogenic system will allow delivery of liquid helium and nitrogen to the three new cryopumps. The Radiative Divertor design is very flexible, and will allow physics studies of the effects of slot width and length. Radiative Divertor diagnostics are being designed in parallel to provide comprehensive measurements for diagnosing the divertor. The Radiative divertor installation is scheduled for late 1996. Engineering experience gained in the DIII-D Advanced Divertor program form a foundation for the design work on the Radiative Divertor

  4. FINAL REPORT FOR THE DIII-D RADIATIVE DIVERTOR PROJECT

    International Nuclear Information System (INIS)

    O'NEIL, RC; STAMBAUGH, RD

    2002-01-01

    OAK A271 FINAL REPORT FOR THE DIII-D RADIATIVE DIVERTOR PROJECT. The Radiative Divertor Project originated in 1993 when the DIII-D Five Year Plan for the period 1994--1998 was prepared. The Project Information Sheet described the objective of the project as ''to demonstrate dispersal of divertor power by a factor of then with sufficient diagnostics and modeling to extend the results to ITER and TPX''. Key divertor components identified were: (1) Carbon-carbon and graphite armor tiles; (2) The divertor structure providing a gas baffle and cooling; and (3) The divertor cryopumps to pump fuel and impurities

  5. Neutron activation behavior of NET/ITER divertor structural materials

    International Nuclear Information System (INIS)

    Smid, I.; Weimann, G.; Kny, E.; Kneringer, G.; Reheis, N.

    1995-01-01

    The post-activation behavior of the materials carbon, TZM (99.3 % Mo) and Mo.41Re, as well as of high temperature brazes suitable for their joining after irradiation with 14 MeV neutrons has been evaluated. The activity, dose rate and energy generation after exposure to an ignited fusion plasma is presented for various time steps after shutdown. The impact of the activity and the afterheat production on the handling and storage conditions of retired divertor components is simulated, the required protection for maintenance is discussed. Further the temperature of stored divertor elements after a full time operation in NET was calculated. No major afterheat production will occur and thus no special cooling is to be provided after approximately one month. Taking into account convection and radiation the equilibrium temperature of vertically stored environment/aircooled divertor elements is predicted to be approximately 100 degree C. (author)

  6. Engineering design of a Radiative Divertor for DIII-D

    International Nuclear Information System (INIS)

    Smith, J.P.; Allen, S.L.; Anderson, P.M.; Baxi, C.B.; Chin, E.; Fenstermacher, M.E.; Hill, D.N.; Hollerbach, M.A.; Hyatt, A.W.; Junge, R.; Mahdavi, M.A.; Porter, G.D.; Redler, K.; Reis, E.E.; Schaffer, M.J.; Sevier, D.L.; Stambaugh, R.D.

    1995-01-01

    A new divertor called the Radiative Divertor is presently being designed for the DIII-D tokamak. Input from tokamak experiments and modeling form the basis for the new design. The Radiative Divertor is intended to reduce the heat flux on the divertor plates by dispersing the power with radiation. Gas puffing experiments in the current open divertor have shown a reduction of the divertor heat flux with either deuterium or impurity puffing. However, either the plasma density (D 2 ) or the core Z eff (impurities) increases in these experiments. The radiative divertor uses a slot structure to isolate the divertor plasma region from the area surrounding the core plasma. Modeling has shown that the Radiative Divertor hardware will provide better baffling and particle control and thereby minimize the effect of the gas puffing in the divertor region on the plasma core. In addition, the Radiative Divertor structure will allow density control in plasma shapes with high triangularity (>0.8) required for advanced tokamak operation. The divertor structure allows for operation in either double or single-null plasma configurations. Four independently controlled divertor cryopumps will enable pumping at either the inboard (upper and lower) or the outboard (upper and lower) divertor plates. Biasing is an integral part of the design and is based on experience at the Tokamak de Varennes (TdeV) and DIII-D. Boron nitride tiles electrically insulate the inner and outer strike points and a low current electrode is used to apply a radial electric field to the scrape-off layer. TdeV has shown that biasing can provide particle and impurity control. The design is extremely flexible, and will allow physics studies of the effect of slot width and height. This is extremely important, as the amount of chamber volume needed for the divertor in future machines such as International Thermonuclear Experiment Reactor (ITER) and Tokamak Physics Experiment (TPX) must be determined. (orig./WL)

  7. Development of a radiative divertor for DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Brooks, N.H.; Campbell, R.B.; Fenstermacher, M.E.; Hill, D.N.; Hyatt, A.W.; Knoll, D.; Lasnier, C.J.; Lazarus, E.A.; Leonard, A.W.; Lippmann, S.I.; Mahdavi, M.A.; Maingi, R.; Meyer, W.; Moyer, R.A.; Petrie, T.W.; Porter, G.D.; Rensink, M.E.; Rognlien, T.D.; Schaffer, M.J.; Smith, J.P.; Staebler, G.M.; Stambaugh, R.D.; West, W.P.; Wood, R.D.

    1995-01-01

    We have used experiments and modeling to develop a new radiative divertor configuration for DIII-D. Gas puffing experiments with the existing open divertor have shown the creation of a localized ( similar 10 cm diameter) radiation zone which results in substantial reduction (3-10) in the divertor heat flux while τ E remains similar 2 times ITER-89P scaling. However, n e increases with D 2 puffing, and Z eff increases with neon puffing. Divertor structures are required to minimize the effects on the core plasma. The UEDGE fluid code, benchmarked with DIII-D data, and the DEGAS neutrals transport code are used to estimate the effectiveness of divertor configurations; slots reduce the core ionization more than baffles. The overall divertor shape is set by confinement studies which indicate that high triangularity (δ∼0.8) is important for high τ E VH-modes. Results from engineering feasibility studies, including diagnostic access, will be presented. ((orig.))

  8. Application of the radiating divertor approach to innovative tokamak divertor concepts

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, T.W., E-mail: petrie@fusion.gat.com [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Allen, S.L.; Fenstermacher, M.E. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Groebner, R.J. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Holcomb, C.T. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Kolemen, E. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); La Haye, R.J. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Leonard, A.W.; Luce, T.C. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Maingi, R. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); Moyer, R.A. [University of California San Diego, 9500 Gilman Dr., La Jolla, CA 92093-0417 (United States); Solomon, W.M. [Princeton Plasma Physics Laboratory, PO Box 451, Princeton, NJ 08543-0451 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, 700 East Ave, Livermore, CA 94550 (United States); Turco, F. [Columbia University, 2960 Broadway, New York, NY 10027 (United States); Watkins, J.G. [Sandia National Laboratory, PO Box 5800, Albuquerque, NM 87185 (United States)

    2015-08-15

    We survey the results of recent DIII-D experiments that tested the effectiveness of three innovative tokamak divertor concepts in reducing divertor heat flux while still maintaining acceptable energy confinement under neon/deuterium-based radiating divertor (RD) conditions: (1) magnetically unbalanced high performance double-null divertor (DND) plasmas, (2) high performance double-null “Snowflake” (SF-DN) plasmas, and (3) single-null H-mode plasmas having different isolation from their divertor targets. In general, all three concepts adapt well to RD conditions, achieving significant reduction in divertor heat flux (q{sub ⊥p}) and maintaining high performance metrics, e.g., 50–70% reduction in peak divertor heat flux for DND and SF-DN plasmas that are characterized by β{sub N} ≅ 3.0 and H{sub 98(y,2)} ≈ 1.35. It is also demonstrated that q{sub ⊥p} could be reduced ≈50% by extending the parallel connection length (L{sub ||-XPT}) in the scrape-off layer between the X-point and divertor targets over a variety of the RD and non-RD environments tested.

  9. The DIII-D Radiative Divertor Project: Status and plans

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Bozek, A.S.

    1996-10-01

    New divertor hardware is being designed and fabricated for the Radiative Divertor modification of the DIII-D tokamak. The installation of the hardware has been separated into two phases, the first phase starting in October of 1996 and the second and final phase, in 1998. The phased approach enables the continuation of the divertor characterization research in the lower divertor while providing pumping for density control in high triangularity, single- or double-null advanced tokamak discharges. When completed, the Radiative Divertor Project hardware will provide pumping at all four strike points of a double-null, high triangularity discharge and provide baffling of the neutral particles from transport back to the core plasma. By puffing neutral gas into the divertor region, a reduction in the heat flux on the target plates will be be demonstrated without a large rise in core density. This reduction in heat flux is accomplished by dispersing the power with radiation in the divertor region. Experiments and modeling have formed the basis for the new design. The capability of the DIII-D cryogenic system is being upgraded as part of this project. The increased capability of the cryogenic system will allow delivery of liquid helium and nitrogen to three new cryopumps. Physics studies on the effects of slot width and length can be accomplished easily with the design of the Radiative Divertor. The slot width can be varied by installing graphite tiles of different geometry. The change in slot length, the distance from the X-point to the target plate, requires relocating the structure vertically and can be completed in about 6-8 weeks. Radiative Divertor diagnostics are being designed to provide comprehensive measurements for diagnosing the divertor. Required diagnostic modifications will be minimal for Phase 1, but extensive for Phase 2 installation. These Phase 2 diagnostics will be required to fully diagnose the high triangularity discharges in the divertor slots

  10. Advantages and Challenges of Radiative Liquid Lithium Divertor

    Science.gov (United States)

    Ono, Masayuki

    2017-10-01

    Steady-state fusion power plant designs present major divertor technology challenges, including high divertor heat flux both in steady-state and during transients. In addition to these concerns, there are the unresolved technology issues of long term dust accumulation and associated tritium inventory and safety issues. The application of lithium (Li) in NSTX resulted in improved H-mode confinement, H-mode power threshold reduction, and reduction in the divertor peak heat flux while maintaining essentially Li-free core plasma operation even during H-modes. These promising results in NSTX and related modeling calculations motivated the radiative liquid Li divertor (RLLD) concept and its variant, the active liquid Li divertor concept (ARLLD), taking advantage of the enhanced Li radiation in relatively poorly confined divertor plasmas. It has been suggested that radiation-based liquid lithium (LL) divertor concepts with a modest Li-loop could provide a possible solution for the outstanding fusion reactor technology issues such as divertor heat flux mitigation and real time dust removal, while potentially improving the reactor plasma performance. Laboratory tests are also planned to investigate the Li-T recover efficiency and other relevant research topics of the RLLD. This work supported by DoE Contract No. DE-AC02-09CH11466.

  11. Study of the radiation in divertor plasmas; Etude du rayonnement dans les plasmas de divertor

    Energy Technology Data Exchange (ETDEWEB)

    Laugier, F

    2000-10-19

    We have studied the cooling of the edge plasma by radiation in the divertor volume, in order to optimize the extraction of power in tokamaks and to limit the wall erosion. In attached divertor plasmas experiments, the concentration of intrinsic impurities at the edge is related to the response of the wall to the incident energy flow of plasma, depending on a phenomenological law. We carried out an analysis of the radiation according to this law and to the control parameters of the discharges. The largest radiated fraction and best synergy are obtained when the concentration of intrinsic impurities strongly increases with the energy of incident plasma. On the other hand, the erosion of the wall is stronger. In detached plasmas, we proved that the performances in terms of incident plasma energy loss and pressure loss are optimal when the density of the slowest neutrals is strong at the edge and when their radial penetration is small. On Tore Supra, we highlighted the correlations between the maximum Mach number of incident plasma flow, the radiation front and the penetration of the neutrals. A simple diagnostic based on the localization of the maximum Mach number proves that detached mode is not optimal on Tore Supra, because the radial penetration of the slowest neutrals is not sufficiently small. In the last part, we obtained the three-dimensional topology of the radiation in the ergodic divertor using a spectral analysis code and boundary conditions consistent with the temperature distribution on the wall. The radiation is maximum in front of the divertor modules. As a consequence, radiated power is underestimated by standards measurements of Tore Supra that are located between the modules. We finally showed that the profiles of temperature along the field lines are modulated, this is specific to the ergodic divertor. (author)

  12. Development of a radiative divertor for DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Allen, S.L. [Lawrence Livermore National Lab., CA (United States); Brooks, N.H. [General Atomics, San Diego, CA (United States); Campbell, R.B. [Sandia National Labs., Albuquerque, NM (United States); Fenstermacher, M.E. [Lawrence Livermore National Lab., CA (United States); Hill, D.N. [Lawrence Livermore National Lab., CA (United States); Hyatt, A.W. [General Atomics, San Diego, CA (United States); Knoll, D.; Lasnier, C.J. [Lawrence Livermore National Lab., CA (United States); Lazarus, E.A. [Oak Ridge National Lab., TN (United States); Leonard, A.W. [General Atomics, San Diego, CA (United States); Lippmann, S.I. [General Atomics, San Diego, CA (United States); Mahdavi, M.A. [General Atomics, San Diego, CA (United States); Maingi, R. [Oak Ridge National Lab., TN (United States); Meyer, W. [Lawrence Livermore National Lab., CA (United States); Moyer, R.A. [California Univ., Los Angeles, CA (United States); Petrie, T.W. [General Atomics, San Diego, CA (United States); Porter, G.D. [Lawrence Livermore National Lab., CA (United States); Rensink, M.E. [Lawrence Livermore National Lab., CA (United States); Rognlien, T.D. [Lawrence Livermore National Lab., CA (United States); Schaffer, M.J. [General Atomics, San Diego, CA (United States); Smith, J.P. [General Atomics, San Diego, CA (United States); Staebler, G.M. [General Atomics, San Diego, CA (United States); Stambaugh, R.D. [General Atomics, San Diego, CA (United States); West, W.P. [General Atomics, San Diego, CA (United States); Wood, R.D. [Lawrence Livermore National Lab., CA (United States)

    1995-04-01

    We have used experiments and modeling to develop a new radiative divertor configuration for DIII-D. Gas puffing experiments with the existing open divertor have shown the creation of a localized ( similar 10 cm diameter) radiation zone which results in substantial reduction (3-10) in the divertor heat flux while {tau}{sub E} remains similar 2 times ITER-89P scaling. However, n{sub e} increases with D{sub 2} puffing, and Z{sub eff} increases with neon puffing. Divertor structures are required to minimize the effects on the core plasma. The UEDGE fluid code, benchmarked with DIII-D data, and the DEGAS neutrals transport code are used to estimate the effectiveness of divertor configurations; slots reduce the core ionization more than baffles. The overall divertor shape is set by confinement studies which indicate that high triangularity ({delta}{approx}0.8) is important for high {tau}{sub E} VH-modes. Results from engineering feasibility studies, including diagnostic access, will be presented. ((orig.)).

  13. Structural design of the DIII-D radiative divertor

    International Nuclear Information System (INIS)

    Reis, E.E.; Smith, J.P.; Baxi, C.B.; Bozek, A.S.; Chin, E.; Hollerbach, M.A.; Laughon, G.J.; Sevier, D.L.

    1996-10-01

    The divertor of the DIII-D tokamak is being modified to operate as a slot type, dissipative divertor. This modification, called the Radiative Divertor Program (RDP) is being carried out in two phases. The design and analysis is complete and hardware is being fabricated for the first phase. This first phase consists of an upper divertor baffle and cryopump to provide some density control for high triangularity, single or double null discharges. Installation of the first phase is scheduled to start in October, 1996. The second phase provides pumping at all four divertor strike points of double null high triangularity discharges and baffling of the neutral particles from transport back to the core plasma. Studies of the effects of varying the slot length and width of the divertor can be easily accomplished with the design of RDP hardware. Static and dynamic analyses of the baffle structures, new cryopumps, and feedlines were performed during the preliminary and final design phases. Disruption loads and differential thermal displacements must be accommodated in the design of these components. With the full RDP hardware installed, the plasma current in DIII-D will be a maximum of 3.0 MA. Plasma disruptions induce toroidal currents in the cryopump, producing complex dynamic loads. Simultaneously, the vacuum vessel vibrations impose a sinusoidal base excitation to the supports for the cryopump. Static and dynamic analyses of the cryopump demonstrate that the stresses due to disruption and thermal loadings satisfy the stress and deflection criteria

  14. Radiative divertor plasmas with convection in DIII-D

    International Nuclear Information System (INIS)

    Leornard, A.W.; Porter, G.D.; Wood, R.D.

    1998-01-01

    The radiation of divertor heat flux on DIII-D is shown to greatly exceed the limits imposed by assumptions of energy transport dominated by electron thermal conduction parallel to the magnetic field. Approximately 90% of the power flowing into the divertor is dissipated through low Z radiation and plasma recombination. The dissipation is made possible by an extended region of low electron temperature in the divertor. A one-dimensional analysis of the parallel heat flux finds that the electron temperature profile is incompatible with conduction dominated parallel transport. Plasma flow at up to the ion acoustic speed, produced by upstream ionization, can account for the parallel heat flux. Modeling with the two-dimensional fluid code UEDGE has reproduced many of the observed experimental features

  15. Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program

    International Nuclear Information System (INIS)

    Bozek, A.S.; Baxi, C.B.; Del Bene, J.V.; Laughon, G.J.; Reis, E.E.; Shatoff, H.D.; Smith, J.P.

    1995-01-01

    A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed to test the change in geometry of the pump feed lines with respect to helium flow stability. The results were compared to the helium thermal and fluid analyses to verify predicted flow regimes and flow stability

  16. A mechanism for large divertor plasma energy loss via lithium radiation in tokamaks

    Science.gov (United States)

    Rognlien, T. D.; Meier, E. T.; Soukhanovskii, V. A.

    2012-10-01

    Lithium has been used as a wall-conditioning element in a number of tokamaks over the years, including TFTR, FTU, and NSTX, where core plasma energy confinement and particle control are often found to improve following such conditioning. Here the possible role of Li in providing substantial energy loss for divertor plasmas via line radiation is reported. A multi-charge-state 2D UEDGE fluid model is used where the hydrogenic and Li ions and neutrals are each evolved as separate species and separate equations are solved for the electron and ion temperatures. It is shown that a sufficient level of Li neutrals evolving from the divertor surface via sputtering or evaporation can induce energy detachment of the divertor plasma, yielding a strongly radiating zone near the divertor where ionization and recombination from/to neutral Li can radiate most of the power flowing into the scrape-off layer while maintaining low core contamination. A local peaking of Li emissivity for electron temperatures near 1 eV appears to play an important role in the detachment of the mixed deuterium/Li plasma. Evidence of such behavior from NSTX discharges will be discussed.

  17. Hybrid formulation of radiation transport in optically thick divertor plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Rosato, J.; Marandet, Y.; Bufferand, H.; Stamm, R. [PIIM, UMR 7345 Aix-Marseille Universite / CNRS, Centre de St-Jerome, Marseille (France); Reiter, D. [IEK-4 Plasmaphysik, Forschungszentrum Juelich GmbH, Juelich (Germany)

    2016-08-15

    Kinetic Monte Carlo simulations of coupled atom-radiation transport in optically thick divertor plasmas can be computationally very demanding, in particular in ITER relevant conditions or even larger devices, e.g. for power plant divertor studies. At high (∝ 10{sup 15} cm{sup -3}) atomic densities, it can be shown that sufficiently large divertors behave in certain areas like a black body near the first resonance line of hydrogen (Lyman α). This suggests that, at least in part, the use of continuum model (radiation hydrodynamics) can be sufficiently accurate, while being less time consuming. In this work, we report on the development of a hybrid model devoted to switch automatically between a kinetic and a continuum description according to the plasma conditions. Calculations of the photo-excitation rate in a homogeneous slab are performed as an illustration. The outlined hybrid concept might be also applicable to neutral atom transport, due to mathematical analogy of transport equations for neutrals and radiation. (copyright 2016 The Authors. Contributions to Plasma Physics published by Wiley-VCH Verlag GmbH and Co. KGaA Weinheim. This)

  18. Radiative divertor plasmas with convection in DIII-D

    International Nuclear Information System (INIS)

    Leonard, A.W.; Porter, G.D.; Wood, R.D.; Allen, S.L.; Boedo, J.; Brooks, N.H.; Evans, T.E.; Fenstermacher, M.E.; Hill, D.N.; Isler, R.C.; Lasnier, C.J.; Lehmer, R.D.; Mahdavi, M.A.; Maingi, R.; Moyer, R.A.; Petrie, T.W.; Schaffer, M.J.; Wade, M.R.; Watkins, J.G.; West, W.P.; Whyte, D.G.

    1998-01-01

    The radiation of divertor heat flux on DIII-D [J. Luxon et al., in Proceedings of the 11th International Conference on Plasma Physics and Controlled Nuclear Fusion (International Atomic Energy Agency, Vienna, 1987), p. 159] is shown to greatly exceed the limits imposed by assumptions of energy transport dominated by electron thermal conduction parallel to the magnetic field. Approximately 90% of the power flowing into the divertor is dissipated through low-Z radiation and plasma recombination. The dissipation is made possible by an extended region of low electron temperature in the divertor. A one-dimensional analysis of the parallel heat flux finds that the electron temperature profile is incompatible with conduction-dominated parallel transport. Plasma flow at up to the ion acoustic speed, produced by upstream ionization, can account for the parallel heat flux. Modeling with the two-dimensional fluid code UEDGE [T. Rognlien, J. L. Milovich, M. E. Rensink, and G. D. Porter, J. Nucl. Mater. 196 endash 198, 347 (1992)] has reproduced many of the observed experimental features. copyright 1998 American Institute of Physics

  19. Comparison of Ne and Ar seeded radiative divertor plasmas in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, T., E-mail: nakano.tomohide@jaea.go.jp

    2015-08-15

    In H-mode plasmas with Ne, Ar and a mixture of Ne and Ar injection, the divertor radiation power fractions amongst these impurities in addition to an intrinsic impurity, C, are investigated. In plasmas with the inner divertor plasma attached, carbon is the biggest radiator, whichever impurity, Ne, Ar or a mixture of Ar and Ne is injected. In contrast, in plasmas with the inner divertor plasma detached, Ne is the biggest radiator due to a significantly high recombination radiation from Ne VIII. Ar is always a minor contributor in plasmas with the inner divertor both attached and detached.

  20. Utilization of vanadium alloys in the DIII-D Radiative Divertor Program

    International Nuclear Information System (INIS)

    Smith, J.P.; Johnson, W.R.; Stambaugh, R.D.; Trester, P.W.; Smith, D.; Bloom, E.

    1995-10-01

    Vanadium alloys are attractive candidate structural materials for fusion power plants because of their potential for minimum environmental impact due to low neutron activation and rapid activation decay. They also possess favorable material properties for operation in a fusion environment. General Atomics (GA), in conjunction with Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL), has developed a plan for the utilization of vanadium alloys as part of the Radiative Divertor (RD) upgrade for the DIII-D tokamak. The plan will be carried out in conjunction with General Atomics and the Materials Program of the US Department of Energy (DOE). This application of a vanadium alloy will provide a meaningful step in the development of advanced materials for fusion power devices by: (1) developing necessary materials processing technology for the fabrication of large vanadium alloy components, and (2) demonstrating the in-service behavior of a vanadium alloy (V-4Cr-4Ti) in a tokamak environment. The program consists of three phases: first, small vanadium alloy coupon samples will be exposed in DIII-D at positions in the vessel floor and within the pumping plenum region of the existing divertor structure; second, a small vanadium alloy component will be installed in the existing divertor, and third, during the forthcoming Radiative Divertor modification, scheduled for completion in mid-1997, the upper section of the new double-null, slotted divertor will be fabricated from vanadium alloy product forms. This program also includes research and development (R and D) efforts to support fabrication development and to resolve key issues related to environmental effects

  1. Utilization of vanadium alloys in the DIII-D radiative divertor program

    International Nuclear Information System (INIS)

    Smith, J.P.; Johnson, W.R.; Stambaugh, R.D.; Trester, P.W.; Smith, D.; Bloom, E.

    1996-01-01

    Vanadium alloys are attractive candidate structural materials for fusion power plants because of their potential for minimum environmental impact due to low neutron activation and rapid activation decay. They also possess favorable material properties for operation in a fusion environment. General Atomics in conjunction with Argonne National Laboratory and Oak Ridge National Laboratory has developed a plan for the utilization of vanadium alloys as part of the radiative divertor upgrade for the DIII-D tokamak. The plan will be carried out in conjunction with General Atomics and the Materials Program of the US Department of Energy. This application of a vanadium alloy will provide a meaningful step in the development of advanced materials for fusion power devices by: (1) developing necessary materials processing technology for the fabrication of large vanadium alloy components and (2) demonstrating the in-service behavior of a vanadium alloy (V-4Cr-4Ti) in a tokamak environment. The program consists of three phases: first, small vanadium alloy coupon samples will be exposed in DIII-D at positions in the vessel floor and within the pumping plenum region of the existing divertor structure; second, a small vanadium alloy component will be installed in the existing divertor, and third, during the forthcoming radiative divertor modification, scheduled for completion in mid-1997, the upper section of the new double-null, slotted divertor will be fabricated from vanadium alloy product forms. This program also includes research and development efforts to support fabrication development and to resolve key issues related to environmental effects. (orig.)

  2. Model-based radiation scalings for the ITER-like divertors of JET and ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Aho-Mantila, L., E-mail: leena.aho-mantila@vtt.fi [VTT Technical Research Centre of Finland, FI-02044 VTT (Finland); Bonnin, X. [LSPM – CNRS, Université Paris 13, Sorbonne Paris Cité, F-93430 Villetaneuse (France); Coster, D.P. [Max-Planck Institut für Plasmaphysik, D-85748 Garching (Germany); Lowry, C. [EFDA JET CSU, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Wischmeier, M. [Max-Planck Institut für Plasmaphysik, D-85748 Garching (Germany); Brezinsek, S. [Forschungszentrum Jülich, Institut für Energie- und Klimaforschung Plasmaphysik, 52425 Jülich (Germany); Federici, G. [EFDA PPP& T Department, D-85748 Garching (Germany)

    2015-08-15

    Effects of N-seeding in L-mode experiments in ASDEX Upgrade and JET are analysed numerically with the SOLPS5.0 code package. The modelling yields 3 qualitatively different radiative regimes with increasing N concentration, when initially attached outer divertor conditions are studied. The radiation pattern is observed to evolve asymmetrically, with radiation increasing first in the inner divertor, then in the outer divertor, and finally on closed field lines above the X-point. The properties of these radiative regimes are observed to be sensitive to cross-field drifts and they differ between the two devices. The modelled scaling of the divertor radiated power with the divertor neutral pressure is similar to an experimental scaling law for H-mode radiation. The same parametric dependencies are not observed in simulations without drifts.

  3. Radiation loss and global energy balance of ohmically heated divertor discharge in JT-60 tokamak

    International Nuclear Information System (INIS)

    Koide, Yoshihiko; Yamada, Kimio; Yoshida, Hidetoshi; Nakamura, Hiroo; Niikura, Setsuo; Tsuji, Shunji

    1986-03-01

    Divertor experiment in JT-60 with a small divertor chamber has been successfully performed up to 1.6 MA discharge. Several divertor effects were experimentally confirmed as follows. Radiation loss in main plasma saturates with the increase of plasma current and its ratio to the input power is about 20 % at 1.5 MA. The rest of input power is exhausted into the divertor chamber and a half of it is dissipated as the radiation loss. Impurity accumulation is not observed during a few sec without internal MHD activity and gross impurity confinement time is several hundred msec. (author)

  4. Scrape-off layer radiation and heat load to the ASDEX Upgrade LYRA divertor

    International Nuclear Information System (INIS)

    Kallenbach, A.; Kaufmann, M.; Coster, D.P.

    1999-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and, in parallel, the neutral beam heating power was increased to 20 MW by installation of a second injector leading to a P/R value of 12 MW/m. Experiments have shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. There is an overall reduction of the maximum heat flux in the LYRA divertor by about a factor of 2 compared with the previous open divertor Div I. This reduction is mainly due to increased radiative losses inside the divertor region, which are caused by an effective reflection of hydrogen neutrals into the hot separatrix region. The main channel of radiative loss is carbon radiation, which cools the divertor plasma down to a few electronvolts, where hydrogen radiation losses become significant. The radiative losses preferentially reduce the power flux at the separatrix, leading to early detachment around the strike point position. With increasing density, the detached region extends upwards on the vertical target. The power fraction radiated in the LYRA divertor is around 45% and nearly independent of the heating power. This value is a factor of 2 higher than the typical radiation fraction in Div I. B2-EIRENE modelling of the performed experiments supports the experimental finding and refines the understanding of loss processes in the divertor region. (author)

  5. Radiation transport effects in divertor plasmas generated during a tokamak reactor disruption

    International Nuclear Information System (INIS)

    Peterson, R.R.; MacFarlane, J.J.; Wang, P.

    1994-01-01

    Vaporization of material from tokamak divertors during disruptions is a critical issue for tokamak reactors from ITER to commercial power plants. Radiation transport from the vaporized material onto the remaining divertor surface plays an important role in the total mass loss to the divertor. Radiation transport in such a vapor is very difficult to calculate in full detail, and this paper quantifies the sensitivity of the divertor mass loss to uncertainties in the radiation transport. Specifically, the paper presents the results of computer simulations of the vaporization of a graphite coated divertor during a tokamak disruption with ITER CDA parameters. The results show that a factor of 100 change in the radiation conductivity changes the mass loss by more than a factor of two

  6. Scrape-off layer and divertor theory meeting: Proceedings

    International Nuclear Information System (INIS)

    1994-03-01

    This report contains viewgraphs on the following topics: fluid modelling of neutrals in the SOL and divertor; instabilities of gas-fueled divertors: theory and adaptive simulations; stability of ionization fronts of gaseous divertor plasmas; monte carlo calculation of heat transport; reduced charge model for edge impurity flows; thermally collapsed solutions for gaseous/radiative divertors; adaptive grid methods in transport simulation; advanced numerical solution algorithms applied to the multispecies edge plasma equations; two-dimensional edge plasma simulation using the multigrid method; neutral behavior and the effects of neutral-neutral and neutral-ion elastic scattering in the ITER gaseous divertor; particle throughput in the TPX divertor; marfes in tokamaks; a comparative study of the limiter and divertor edge plasmas in TEXT-U; issues of toroidal tokamak-type divertor simulators; ASDEX upgrade; the ITER divertor; the DIII-D divertor program and TPX divertor; DEGAS 2: a transmission/escape probabilities model for neutral particle transport: comparison with DEGAS 2; a collisional radiative model of hydrogen for high recycling divertors; comparison of fluid and non- fluid neutral models in B2.5; DIII-D radiative divertor simulations; 3-D fluid simulations of turbulence from conducting wall mode; turbulence and drifts in SOL plasmas; recent results for 1 1/2-D ITER gas target divertor modelling; evaluation of pumping and fueling in coupled core, SOL, and divertor chamber calculations; and ITER gas target divertors: comparison of volume recombination and large radial transport scenarios using DEGAS

  7. Heat loads to divertor nearby components from secondary radiation evolved during plasma instabilities

    Energy Technology Data Exchange (ETDEWEB)

    Sizyuk, V., E-mail: vsizyuk@purdue.edu; Hassanein, A., E-mail: hassanein@purdue.edu [Center for Materials under Extreme Environment, School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907 (United States)

    2015-01-15

    A fundamental issue in tokamak operation related to power exhaust during plasma instabilities is the understanding of heat and particle transport from the core plasma into the scrape-off layer and to plasma-facing materials. During abnormal and disruptive operation in tokamaks, radiation transport processes play a critical role in divertor/edge-generated plasma dynamics and are very important in determining overall lifetimes of the divertor and nearby components. This is equivalent to or greater than the effect of the direct impact of escaped core plasma on the divertor plate. We have developed and implemented comprehensive enhanced physical and numerical models in the upgraded HEIGHTS package for simulating detailed photon and particle transport in the evolved edge plasma during various instabilities. The paper describes details of a newly developed 3D Monte Carlo radiation transport model, including optimization methods of generated plasma opacities in the full range of expected photon spectra. Response of the ITER divertor's nearby surfaces due to radiation from the divertor-developed plasma was simulated by using actual full 3D reactor design and magnetic configurations. We analyzed in detail the radiation emission spectra and compared the emission of both carbon and tungsten as divertor plate materials. The integrated 3D simulation predicted unexpectedly high damage risk to the open stainless steel legs of the dome structure in the current ITER design from the intense radiation during a disruption on the tungsten divertor plate.

  8. Radiative and SOL experiments in open and baffled divertors on DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Brooks, N.H.; Bastasz, R.

    1998-11-01

    The authors present recent progress towards an understanding of the physical processes in the divertor and scrape-off-layer (SOL) plasmas in DIII-D. This has been made possible by a combination of new diagnostics, improved computational models, and changes in divertor geometry. They have focused primarily on ELMing H-mode discharges. The physics of Partially Detached Divertor (PDD) plasmas, with divertor heat flux reduction by divertor radiation enhancement using D 2 puffing, has been studied in 2-D, and a model of the heat and particle transport has been developed that includes conduction, convection, ionization, recombination, and flows. Plasma and impurity particle flows have been measured with Mach probes and spectroscopy and these flows have been compared with the UEDGE model. The model now includes self-consistent calculations of carbon impurities. Impurity radiation has been increased in the divertor and SOL with puff and pump techniques using SOL D 2 puffing, divertor cryopumping, and argon puffing. The important physical processes in plasma-wall interactions have been examined with a DiMES probe, plasma characterization near the divertor plate, and the REDEP code. Experiments comparing single-null (SN) plasma operation in baffled and open divertors have demonstrated a change in the edge plasma profiles. These results are consistent with a reduction in the core ionization source calculated with UEDGE. Divertor particle control in ELMing H-mode with pumping and baffling has resulted in reduction in H-mode core densities to n e /n gw ∼ 0.25. Divertor particle exhaust and heat flux has been studied as the plasma shape was varied from a lower SN, to a balanced double null (DN), and finally to an upper SN

  9. Energy and particle transport in the radiative divertor plasmas of DIII-D

    International Nuclear Information System (INIS)

    Leonard, A.W.; Allen, S.L.; Brooks, N.H.

    1997-06-01

    It has been argued that divertor energy transport dominated by parallel electron thermal conduction, or q parallel = -kT 5/2 2 dT e /ds parallel, leads to severe localization of the intense radiating region and ultimately limits the fraction of energy flux that can be radiated before striking the divertor target. This is due to the strong T 5/2 e dependence of electron heat conduction which results in very short spatial scales of the T e gradient at high power densities and low temperatures where deuterium and impurities radiate most effectively. However, we have greatly exceeded this constraint on DIII-D with deuterium gas puffing which reduces the peak heat flux to the divertor plate a factor of 5 while distributing the divertor radiation over a long length

  10. Radiation power profiles and density limit with a divertor in the W7-AS stellarator

    International Nuclear Information System (INIS)

    Giannone, L.; Burhenn, R.; McCormick, K.; Brakel, R.; Feng, Y.; Grigull, P.; Igitkhanov, Y.

    2002-01-01

    The addition of a divertor into the W7-AS stellarator has allowed access to a high density regime where the radiation profiles reach a steady state. In earlier limiter discharges, the plasma suffered a radiative collapse at high densities. In contrast to limiter experiments, where the impurity confinement time measured by Al laser blow-off increased with increasing line integrated density, in divertor discharges, above a density threshold, the impurity confinement time decreased with increasing line integrated density. The observation that the divertor plasma radiates mainly at the plasma edge rather than the plasma centre is a further indication that changes to the impurity transport coefficients at these high densities are the basis for the achievement of steady state discharges in the divertor configuration of W7-AS. The maximum line integrated density reached with a divertor is compared to that reached with a limiter. The previously derived scaling law for the density limit with a limiter shows that the achieved densities do not exceed those predicted when the higher deposited power is taken into account. In a divertor the radiated power is located at the plasma edge and increasing the density, cooling the plasma edge and radiating sufficient power to cause plasma detachment determines the density limit. (author)

  11. Atomic and molecular processes in JT-60U divertor plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Takenaga, H.; Shimizu, K.; Itami, K. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1997-01-01

    Atomic and molecular data are indispensable for the understanding of the divertor characteristics, because behavior of particles in the divertor plasma is closely related to the atomic and molecular processes. In the divertor configuration, heat and particles escaping from the main plasma flow onto the divertor plate along the magnetic field lines. In the divertor region, helium ash must be effectively exhausted, and radiation must be enhanced for the reduction of the heat load onto the divertor plate. In order to exhaust helium ash effectively, the difference between behavior of neutral hydrogen (including deuterium and tritium) and helium in the divertor plasma should be understood. Radiation from the divertor plasma generally caused by the impurities which produced by the erosion of the divertor plate and/or injected by gas-puffing. Therefore, it is important to understand impurity behavior in the divertor plasma. The ions hitting the divertor plate recycle through the processes of neutralization, reflection, absorption and desorption at the divertor plates and molecular dissociation, charge-exchange reaction and ionization in the divertor plasma. Behavior of hydrogen, helium and impurities in the divertor plasmas can not be understood without the atomic and molecular data. In this report, recent results of the divertor study related to the atomic and molecular processes in JT-60U were summarized. Behavior of neural deuterium and helium was discussed in section 2. In section 3, the comparisons between the modelling of the carbon impurity transport and the measurements of C II and C IV were discussed. In section 4, characteristics of the radiative divertor using Ne puffing were reported. The new diagnostic method for the electron density and temperature in the divertor plasmas using the intensity ratios of He I lines was described in section 5. (author)

  12. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, W.R.; Smith, J.P.; Trester, P.W.

    1997-04-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy, and processing into final sheet and rod product forms suitable for components of the DIII-D Radiative Divertor structure, has been completed at Wah Chang (formerly Teledyne Wah Chang) of Albany, Oregon (WCA). Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RD Program, and research into several joining methods for fabrication of the RD components, including resistance seam, friction, and electron beam welding, is continuing. Preliminary trials have been successful in the joining of V-alloy to itself by electron beam, resistance, and friction welding processes, and to Inconel 625 by friction welding. An effort to investigate the explosive bonding of V-4Cr-4Ti alloy to Inconel 625 has also been initiated, and results have been encouraging. In addition, preliminary tests have been completed to evaluate the susceptibility of V-4Cr-4Ti alloy to stress corrosion cracking in DIII-D cooling water, and the effects of exposure to DIII-D bakeout conditions on the tensile and fracture behavior of V-4Cr-4Ti alloy.

  13. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D

    International Nuclear Information System (INIS)

    Johnson, W.R.; Smith, J.P.; Trester, P.W.

    1997-01-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy, and processing into final sheet and rod product forms suitable for components of the DIII-D Radiative Divertor structure, has been completed at Wah Chang (formerly Teledyne Wah Chang) of Albany, Oregon (WCA). Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RD Program, and research into several joining methods for fabrication of the RD components, including resistance seam, friction, and electron beam welding, is continuing. Preliminary trials have been successful in the joining of V-alloy to itself by electron beam, resistance, and friction welding processes, and to Inconel 625 by friction welding. An effort to investigate the explosive bonding of V-4Cr-4Ti alloy to Inconel 625 has also been initiated, and results have been encouraging. In addition, preliminary tests have been completed to evaluate the susceptibility of V-4Cr-4Ti alloy to stress corrosion cracking in DIII-D cooling water, and the effects of exposure to DIII-D bakeout conditions on the tensile and fracture behavior of V-4Cr-4Ti alloy

  14. Features and Initial Results of the DIII-D Advanced Tokamak Radiative Divertor

    International Nuclear Information System (INIS)

    R.C. O'Neill; A.S. Bozek; M.E. Friend; C.B. Baxi; E.E. Reis; M.A. Mahdavi; D.G. Nilson; S.L. Allen; W.P. West

    1999-01-01

    The Radiative Divertor Program of DIII-D is in its final phase with the installation of the cryopump and baffle structure (Phase 1B Divertor) in the upper inner radius of the DIII-D vacuum vessel at the end of this calendar year. This divertor, in conjunction with the Advanced Divertor and the Phase 1A Divertor, located in the lower and upper outer radius of the DIII-D vacuum vessel respectively, provides pumping for density control of the plasma while minimizing the effects on the core confinement. Each divertor consists of a cryobelium cooling ring and a shielded protective structure. The cryo/helium-cooled pumps of all three diverters exhaust helium from the plasma. The protective shielded structure or baffle structure, in the case of the diverters located at the top of the vacuum vessel, provides baffling of neutral charged particles and minimize the flow of impurities back into the core of the plasma. The baffles, which consist of water-cooled panels that allow for the attachment of tiles of various sizes and shapes, house gas puff systems. The intent of the puffing systems is to inject gas in and around the divertor to minimize the heat flux on specific areas on the divertor and its components. The reduction of the heat flux on the divertor minimizes the impurities that are generated from excess heat on divertor components, specifically tiles. Experiments involving the gas puff systems and the divertor structures have shown the heat flux can be spread over a large area of the divertor, reducing the peak heat flux in specific areas. The three diverters also incorporate a variety of diagnostic tools such as halo current monitors, magnetic probes and thermocouples to monitor certain plasma characteristics as well as determine the effectiveness of the cryopumps and baffle configurations. The diverters were designed to optimize pumping performance and to withstand the electromagnetic loads from both halo currents and toroidal induced currents. Incorporated also

  15. Thermal and radiation loads on the first wall and divertor plates in the KTM tokamak

    International Nuclear Information System (INIS)

    Azizov, Eh.A.; Buzhinskij, O.I.; Gladush, G.G.; Darmagraj, V.V.; Priyampol'skij, I.R.; Dvorkin, N.Ya.; Lejkin, I.N.; Tazhibaeva, I.L.; Shestakov, V.P.

    2001-01-01

    The constructing of the KTM tokamak is intended for wide scale studies of behavior both inner-chamber element materials and structures (first wall, limiters, divertor, hf-antennas, etc.) under conditions approaching to the ITER-FEAT and a future thermonuclear reactors. The KTM tokamak is designed for maintain of interaction conditions of plasma-wall, plasma flows and divertor field, stimulating conditions of ITER-FEAT; and for examination of a future tokamaks' materials. In the work the thermal loads on the first wall, divertor plates are presented

  16. Vanadium alloys for the radiative divertor program of DIII-D

    International Nuclear Information System (INIS)

    Smith, J.P.; Johnson, W.R.; Stambaugh, R.D.; Trester, P.W.; Smith, D.; Bloom, E.

    1995-10-01

    Vanadium alloys provide an attractive solution for fusion power plants as they exhibit a potential for low environmental impact due to low level of activation from neutron fluence and a relatively short half-life. They also have attractive material properties for use in a reactor. General Atomics along with Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL), has developed a plan to utilize vanadium alloys as part of the Radiative Divertor Project (RDP) modification for the DIII-D tokamak. The goal for using vanadium alloys is to provide a meaningful step towards developing advanced materials for fusion power applications by demonstrating the in-service behavior of a vanadium alloy (V-4Cr-4Ti) in a tokamak in conjunction with developing essential fabrication technology for the manufacture of full-scale vanadium alloy components. A phased approach towards utilizing vanadium in DIII-D is being used starting with small coupons and samples, advancing to a small component, and finally a portion of the new double-null, slotted divertor will be fabricated from vanadium alloy product forms. A major portion of the program is research and development to support fabrication and resolve key issues related to environmental effects

  17. Assessment of radiation maps during activated divertor moving in the ITER building

    International Nuclear Information System (INIS)

    Ying Dongchuan; Zeng Qin; Qiu Yuefeng; Dang Tongqiang; Wu Yican; Loughlin, Michael

    2011-01-01

    As the main interface components between plasma and vacuum vessel, the divertor is foreseen to be removed to the hot cell for refurbishment during the 20 years of ITER operation. During this process, the activated divertor will cause a large increase of radiation in the ITER building. 3D analysis has been performed to assess the radiation maps throughout the ITER building for assisting the shielding design for personnel and sensitive equipment. The activation of the divertor has been determined by coupled neutron transport and inventory calculations, radiation maps have been obtained from gamma transport calculations. The neutron and gamma transport calculations have been performed by MCNP5 code with FENDL2.1library. The inventory calculations have been performed by FISPACT2007 code with EAF-2007 library. The results of these 3D decay gamma radiation maps are presented by pictures in this paper, including the biological dose maps and maps of heat deposition in electronic equipment.

  18. Design and analysis of the DII-D radiative divertor water-cooled structures

    International Nuclear Information System (INIS)

    Hollerbach, M.A.; Smith, J.P.; Baxi, C.B.; Bozek; Chin, E.; Phelps, R.D.; Redler, K.M.; Reis, E.E.

    1995-10-01

    The Radiative Divertor is a major modification to the divertor of DIII-D and is being designed and fabricated for installation in late 1996. The Radiative Divertor Program (RDP) will enhance the dissipative processes in the edge and divertor plasmas to reduce the heat flux and plasma erosion at the divertor target. This approach will have major implications for the heat removal methods used in future devices. The divertor is of slot-type configuration designed to minimize the flow of sputtered and injected impurities back to the core plasma. The new divertor will be composed of toroidally continuous, Inconel 625 water-cooled rings of sandwich construction with an internal water channel, incorporating seam welding to provide the water-to-vacuum seal as well as structural integrity. The divertor structure is designed to withstand electromagnetic loads as a result of halo currents and induced toroidal currents. It also accommodates the thermal differences experienced during the 400 degrees C bake used on DIII-D. A low Z plasma-facing surface is provided by mechanically attached graphite tiles. Water flow through the rings will inertially cool these tiles which will be subjected to 38 MW, 10 second pulses. Current schedules call for detailed design in 1996 with installation completed in March 1997. A full size prototype, one-quarter of one ring, is being built to validate manufacturing techniques, machining, roll-forming, and seam welding. The experience and knowledge gained through the fabrication of the prototype is discussed. The design of the electrically isolated (5 kV) vacuum-to-air water feedthroughs supplying the water-cooled rings is also discussed

  19. Design and analysis of the DIII-D radiative divertor water-cooled structures

    International Nuclear Information System (INIS)

    Hollerbach, M.A.; Smith, J.P.; Baxi, C.B.; Bozek, A.S.; Chin, E.; Phelps, R.D.; Redler, K.M.; Reis, E.E.

    1995-01-01

    The Radiative Divertor is a major modification to the divertor of DIII-D and is being designed and fabricated for installation in late 1996. The Radiative Divertor Program (RDP) will enhance the dissipative processes in the edge and divertor plasmas to reduce the heat flux and plasma erosion at the divertor target. This approach will have major implications for the heat removal methods used in future devices. The divertor is of slot-type configuration designed to minimize the flow of sputtered and injected impurities back to the core plasma. The new divertor will be composed of toroidally continuous, Inconel 625 water-cooled rings of sandwich construction with an internal water channel, incorporating seam welding to provide the water-to-vacuum seal as well as structural integrity. The divertor structure is designed to withstand electro-magnetic loads as a result of halo currents and induced toroidal currents. It also accommodates the thermal differences experienced during the 400 C bake used on DIII-D. A low Z plasma-facing surface is provided by mechanically attached graphite tiles. Water flow through the rings will inertially cool these tiles which will be subjected to 38 MW, 10 second pulses. Current schedules call for detailed design in 1996 with installation completed in March 1997. A full size prototype, one-quarter of one ring, is being built to validate manufacturing techniques, machining, roll-forming, and seam welding. The experience and knowledge gained through the fabrication of the prototype is discussed. The design of the electrically isolated (5 kV) vacuum-to-air water feedthroughs supplying the water-cooled rings is also discussed

  20. 2-D fluid transport simulations of gaseous/radiative divertors

    International Nuclear Information System (INIS)

    Rognlien, T.D.; Brown, P.N.; Campbell, R.B.; Kaiser, T.B.; Knoll, D.A.; McHugh, P.R.; Porter, G.D.; Rensink, M.E.; Smith, G.R.

    1994-01-01

    The features of the fully implicit 2-D fluid code UEDGE are described. The utility of the code is demonstrated by showing bifurcations or multiple solutions of the tokamak edge plasma for both deuterium and impurity injection in the divertor. (orig.)

  1. Divertor detachment

    Science.gov (United States)

    Krasheninnikov, Sergei

    2015-11-01

    The heat exhaust is one of the main conceptual issues of magnetic fusion reactor. In a standard operational regime the large heat flux onto divertor target reaches unacceptable level in any foreseeable reactor design. However, about two decades ago so-called ``detached divertor'' regimes were found. They are characterized by reduced power and plasma flux on divertor targets and look as a promising solution for heat exhaust in future reactors. In particular, it is envisioned that ITER will operate in a partly detached divertor regime. However, even though divertor detachment was studied extensively for two decades, still there are some issues requiring a new look. Among them is the compatibility of detached divertor regime with a good core confinement. For example, ELMy H-mode exhibits a very good core confinement, but large ELMs can ``burn through'' detached divertor and release large amounts of energy on the targets. In addition, detached divertor regimes can be subject to thermal instabilities resulting in the MARFE formation, which, potentially, can cause disruption of the discharge. Finally, often inner and outer divertors detach at different plasma conditions, which can lead to core confinement degradation. Here we discuss basic physics of divertor detachment including different mechanisms of power and momentum loss (ionization, impurity and hydrogen radiation loss, ion-neutral collisions, recombination, and their synergistic effects) and evaluate the roles of different plasma processes in the reduction of the plasma flux; detachment stability; and an impact of ELMs on detachment. We also evaluate an impact of different magnetic and divertor geometries on detachment onset, stability, in- out- asymmetry, and tolerance to the ELMs. Supported by the U.S. Department of Energy Office of Science, Office of Fusion Energy Sciences under Award Number DE-DE-FG02-04ER54739 at UCSD.

  2. Advanced divertor concepts

    International Nuclear Information System (INIS)

    Ohyabu, N.; Komori, A.; Sagara, A.; Suzuki, H.; Morisaki, T.; Masuzaki, S.; Watanabe, T.; Noda, N.; Motojima, O.

    1996-01-01

    LHD divertor development program has generated various innovative divertor concepts and technologies which will help to improve the plasma performance in both helical and tokamak devices. They are two divertor operational scenarios (confinement improvement by generating high temperature divertor plasma and simultaneous achievement of radiative cooling and H-mode-like confinement improvement). Local island divertor geometry has also been proposed. This new divertor has been successfully tested in the CHS device and is planned to be installed in the LHD device. In addition, technological development of new efficient hydrogen pumping schemes (carbon sheet pump and membrane pump) are being pursued for enhancement of the divertor control capability. 17 refs., 8 figs

  3. Fabrication and installation of the DIII-D radiative divertor structures

    International Nuclear Information System (INIS)

    Hollerbach, M.A.; Smith, J.P.

    1997-11-01

    Phase 1A of the Radiative Divertor Program (RDP) is now installed in the DIII-D tokamak located at General Atomics. This hardware was added to enhance both the Divertor and Advanced Tokamak research elements of the DIII-D program. This installation consists of a divertor baffle enveloping a cryocondensation pump at the upper outer divertor target of DIII-D. The divertor baffle consists of two toroidally continuous Inconel 625 water-cooled rings and a toroidal array of discontinuous radiatively-cooled plates. The water-cooled rings are each comprised of four quadrants, mechanically formed, chem.-milled, and resistance and TIG welded Inconel 625 panels. The supports attaching the panels to the vessel wall are designed to accommodate the differential thermal expansion between the rings and vessel during bake and to react the electromagnetic loads induced during disruptions. They are made from either Inconel 625 or Inconel 718 depending on the stress levels predicted in Finite Element Analysis. Gas seals are designed to limit the leakage from the baffle chamber back to the core plasma to 2,500 ell/s and incorporate plasma sprayed alumina to minimize currents flowing through them. The bulk of the water-cooled ring fabrication was performed by a vendor, however, the final machining of penetrations in the conical ring for diagnostic access was performed in-house using a unique machining configuration. This configuration, and the machining of the diagnostic cutouts is described. Graphite tiles were machined from ATJ graphite to form a smooth plasma-facing surface. The installation of all divertor components required only four weeks

  4. Development of impurity seeding and radiation enhancement in the helical divertor of LHD

    International Nuclear Information System (INIS)

    Mukai, K.; Masuzaki, S.; Peterson, B.J.

    2014-10-01

    Impurity seeding for the reduction of the divertor heat load was conducted in the Large Helical Device (LHD) using neon (Ne) and krypton (Kr) puffing. Enhanced radiation loss and reduction of the divertor heat load were observed without significant changes in stored energy and line averaged density. In the LHD, the radiated power fraction of the heating power, P rad /P heating , where P rad and P heating are the total radiation power and the heating power, respectively, is limited up to around 30% in hydrogen plasmas even for high density plasma just below the radiative collapse (n e,bar > 1 × 10 20 m -3 ), where n e,bar is the line averaged density. With Ne seeding, the ratio could be raised to 52% in spite of much lower density (n e,bar ∼ 1.3 × 10 19 m -3 ), albeit with a slight reduction in confinement. P rad /P heating ∼ 30% could be sustained for 3.4 s using multi-pulse Ne seeding in relatively high density plasmas in this study (n e,bar ∼ 4 × 10 19 m -3 ). Radiation profile measurement with an InfraRed Imaging Video Bolometer (IRVB) was conducted during Ne seeding. The localized supplemental radiation was observed along the helical divertor X-points (HDXs). The enhanced radiation structure was similar to the Ne radiation profile estimated by EMC3-EIRENE code. Kr seeding was also conducted to the plasma of n e,bar ∼ 3.1 × 10 19 m -3 . P rad /P heating ∼ 25% was obtained without significant change in stored energy. The enhancement of the plasma radiation has a slower time constant compared with the Ne seeding. The supplemental radiation area of the Kr seeded plasma moved from the HDXs to the core plasma. High-valent Kr ions are considered to be the dominant radiators from the plasma core region. (author)

  5. Evaluating Stellarator Divertor Designs with EMC3

    Science.gov (United States)

    Bader, Aaron; Anderson, D. T.; Feng, Y.; Hegna, C. C.; Talmadge, J. N.

    2013-10-01

    In this paper various improvements of stellarator divertor design are explored. Next step stellarator devices require innovative divertor solutions to handle heat flux loads and impurity control. One avenue is to enhance magnetic flux expansion near strike points, somewhat akin to the X-Divertor concept in Tokamaks. The effect of judiciously placed external coils on flux deposition is calculated for configurations based on the HSX stellarator. In addition, we attempt to optimize divertor plate location to facilitate the external coil placement. Alternate areas of focus involve altering edge island size to elucidate the driving physics in the edge. The 3-D nature of stellarators complicates design and necessitates analysis of new divertor structures with appropriate simulation tools. We evaluate the various configurations with the coupled codes EMC3-EIRENE, allowing us to benchmark configurations based on target heat flux, impurity behavior, radiated power, and transitions to high recycling and detached regimes. Work supported by DOE-SC0006103.

  6. Radiative and three-body recombination in the Alcator C-Mod divertor

    International Nuclear Information System (INIS)

    Lumma, D.; Terry, J.L.; Lipschultz, B.

    1997-01-01

    Significant recombination of the majority ion species has been observed in the divertor region of Alcator C-Mod [I. H. Hutchinson et al., Phys. Plasmas 1, 1511 (1994)] under detached conditions. This determination is made by analysis of the visible spectrum from the divertor, in particular the Balmer series line emission and the observed recombination continuum, including an apparent recombination edge at ∼375 nm. The analysis shows that the electron temperature in the recombining plasma is 0.8 endash 1.5 eV. The measured volume recombination rate is comparable to the rate of ion collection at the divertor plates. The dominant recombination mechanism is three-body recombination into excited states (e+e+D + Right-arrow D 0 +e), although radiative recombination (e+D + Right-arrow D 0 +hν) contributes ∼5% to the total rate. Analysis of the Balmer series line intensities (from n upper =3 through 10) shows that the upper levels of these transitions are populated primarily by recombination. Thus the brightnesses of the Balmer series (and Lyman series) are directly related to the recombination rate. copyright 1997 American Institute of Physics

  7. LHD helical divertor

    International Nuclear Information System (INIS)

    Ohyabu, N.; Watanabe, T.; Ji Hantao

    1993-07-01

    The Large Helical Device (LHD) now under construction is a heliotron/torsatron device with a closed divertor system. The edge LHD magnetic structure has been studied in detail. A peculiar feature of the configuration is existence of edge surface layers, a complicated three dimensional magnetic structure which does not, however, seem to hamper the expected divertor functions. Two divertor operational modes are being considered for the LHD experiment, high density, cold radiative divertor operation as a safe heat removal scheme and high temperature divertor plasma operation. In the latter operation, a divertor plasma with temperature of a few kev, generated by efficient pumping, expects to lead to significant improvement in core plasma confinement. Conceptual designs of the LHD divertor components are under way. (author)

  8. Spatial radiation profiles in the ASDEX Upgrade divertor for detached plasmas

    International Nuclear Information System (INIS)

    Wenzel, U.; Thoma, A.; Dux, R.; Fuchs, C.; Herrmann, A.; Hirsch, S.; Kallenbach, A.; Kastelewicz, H.; Laux, M.; Mast, F.; Napiontek, B.

    1997-01-01

    In this paper we describe impurity line emission measurements in the divertor of ASDEX Upgrade during high power neutral beam heated discharges. We focus on detached conditions where the dominating part of the radiation comes from the X-point region. Spatially resolved line emission in the VUV and visible spectral region of the intrinsic carbon and additionally puffed impurities (neon and nitrogen) is presented. A simple interpretation of the line emission profiles is given and they are also compared to the results of bolometry. (orig.)

  9. Divertor materials for ITER - Tungsten and carbon/carbon composite behavior under coupled ionic irradiation and high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Raunier, S.; Balat-Pichelin, M.; Sans, J.L.; Hernandez, D. [Laboratoire PROMES-CNRS, Laboratoire Procedes, Materiaux et Energie Solaire, 7 rue du Four Solaire, 66120 Font-Romeu Odeillo (France)

    2007-07-01

    Full text of publication follows: In the frame of the International Thermonuclear Experimental Reactor ITER, the physical-chemical characterization of plasma-facing components (divertor and structural materials) is essential because they are subjected to simultaneous high thermal and ionic fluxes. In this paper, an experimental and theoretical study of the physical-chemical behavior of carbon/carbon composite and tungsten (materials for ITER divertor) under extreme conditions is performed. The simulation of the interaction of hydrogen ions with the material, the theoretical study of physical erosion (TRIM and TRIDYN codes) and the chemical erosion (GEMINI code) are carried out. The conditions of nominal or accidental mode that can occur during the operation of the reactor (high temperature 1300 - 2500 K, high vacuum, H{sup +} ionic flux with different energies) are experimentally simulated. In this work, we have studied the material degradation, the mass loss kinetics, the characterization of the emitted neutral and charged species of heated and both heated and irradiated materials, and the determination of the thermo-radiative properties versus time. This study, done in collaboration with CEA Cadarache, is realized using the MEDIASE experimental device (Moyen d'Essai et de Diagnostic en Ambiance Solaire Extreme) located at the focus of the 1000 kW solar furnace of PROMES-CNRS laboratory in Odeillo. Material characterization pre- and post-processing is performed with classical techniques as SEM, XRD and XPS and also by measuring the BRDF (Bidirectional Reflectivity Diffusion Function). (authors)

  10. Divertor materials for ITER - Tungsten and carbon/carbon composite behavior under coupled ionic irradiation and high temperature

    International Nuclear Information System (INIS)

    Raunier, S.; Balat-Pichelin, M.; Sans, J.L.; Hernandez, D.

    2007-01-01

    Full text of publication follows: In the frame of the International Thermonuclear Experimental Reactor ITER, the physical-chemical characterization of plasma-facing components (divertor and structural materials) is essential because they are subjected to simultaneous high thermal and ionic fluxes. In this paper, an experimental and theoretical study of the physical-chemical behavior of carbon/carbon composite and tungsten (materials for ITER divertor) under extreme conditions is performed. The simulation of the interaction of hydrogen ions with the material, the theoretical study of physical erosion (TRIM and TRIDYN codes) and the chemical erosion (GEMINI code) are carried out. The conditions of nominal or accidental mode that can occur during the operation of the reactor (high temperature 1300 - 2500 K, high vacuum, H + ionic flux with different energies) are experimentally simulated. In this work, we have studied the material degradation, the mass loss kinetics, the characterization of the emitted neutral and charged species of heated and both heated and irradiated materials, and the determination of the thermo-radiative properties versus time. This study, done in collaboration with CEA Cadarache, is realized using the MEDIASE experimental device (Moyen d'Essai et de Diagnostic en Ambiance Solaire Extreme) located at the focus of the 1000 kW solar furnace of PROMES-CNRS laboratory in Odeillo. Material characterization pre- and post-processing is performed with classical techniques as SEM, XRD and XPS and also by measuring the BRDF (Bidirectional Reflectivity Diffusion Function). (authors)

  11. Innovative divertor concepts for LHD

    International Nuclear Information System (INIS)

    Ohyabu, N.; Komori, A.; Akaishi, K.

    1994-07-01

    We are developing various innovative divertor concepts which improve the LHD plasma performance. These are two divertor magnetic geometries (helical and local island divertors), three operational scenarios (radiative cooling in the high density, cold boundary, confinement improvement by generating high temperature divertor plasma and simultaneous achievement of radiative cooling and H-mode like confinement improvement) and technological development of new efficient hydrogen pumping schemes. (author)

  12. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, W.R.; Smith, J.P.

    1997-08-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy, and processing into final sheet and rod product forms suitable for components of the DIII-D Radiative Divertor Program (RDP), has been completed by Wah Chang (formerly Teledyne Wah Chang) of Albany, Oregon (WCA). CVN impact tests on sheet material indicate that the material has properties comparable to other previously-processed V-4Cr-4Ti and V-5Cr-5Ti alloys. Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RDP, and research into several joining methods for fabrication of the RDP components, including resistance seam, friction, and electron beam welding, and explosive bonding is being pursued. Preliminary trials have been successful in the joining of V-alloy to itself by resistance, friction, and electron beam welding processes, and to Inconel 625 by friction welding. In addition, an effort to investigate the explosive bonding of V-4Cr-4Ti alloy to Inconel 625, in both tube-to-bar and sheet-to-sheet configurations, has been initiated, and results have been encouraging.

  13. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D

    International Nuclear Information System (INIS)

    Johnson, W.R.; Smith, J.P.

    1997-01-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy, and processing into final sheet and rod product forms suitable for components of the DIII-D Radiative Divertor Program (RDP), has been completed by Wah Chang (formerly Teledyne Wah Chang) of Albany, Oregon (WCA). CVN impact tests on sheet material indicate that the material has properties comparable to other previously-processed V-4Cr-4Ti and V-5Cr-5Ti alloys. Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RDP, and research into several joining methods for fabrication of the RDP components, including resistance seam, friction, and electron beam welding, and explosive bonding is being pursued. Preliminary trials have been successful in the joining of V-alloy to itself by resistance, friction, and electron beam welding processes, and to Inconel 625 by friction welding. In addition, an effort to investigate the explosive bonding of V-4Cr-4Ti alloy to Inconel 625, in both tube-to-bar and sheet-to-sheet configurations, has been initiated, and results have been encouraging

  14. Low cycle fatigue behavior of ITER-like divertor target under DEMO-relevant operation conditions

    Energy Technology Data Exchange (ETDEWEB)

    Li, Muyuan; Werner, Ewald [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); You, Jeong-Ha, E-mail: you@ipp.mpg.de [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-01-15

    Highlights: • LCF behavior of the cooling tube and the interlayer of an ITER-like divertor target is studied. • For the cooling tube, LCF failure will not be an issue under an HHF load of up to 18 MW/m{sup 2}. • Plastic strain in the interlayer is concentrated at the free surface edge of the bond interface. • The predicted LCF lifetime of the interlayer may not meet the design requirement. - Abstract: In this work the low cycle fatigue (LCF) behavior of the copper alloy cooling tube and the copper interlayer of an ITER-like divertor target is reported for nine different combinations of loading and cooling conditions relevant to DEMO divertor operation. The LCF lifetime is presented as a function of loading and cooling conditions considered here by means of cyclic plasticity simulation and using LCF data of materials relevant for ITER. The numerical predictions indicate, that fatigue failure will not be an issue for the copper alloy tube under a high heat flux (HHF) load of up to 18 MW/m{sup 2} as long as it preserves its initial strength. In contrast, the copper interlayer exhibits significant plastic dissipation at the free surface edge of the bond interface adjacent to the cooling tube, where the LCF lifetime is predicted to be below 3000 load cycles for HHF loads higher than 15 MW/m{sup 2}. Most of the bulk region of the copper interlayer away from the free surface edge does not experience severe plastic fatigue and hence does not pose any critical concern as the LCF lifetime is predicted to be at least 7000 load cycles. LCF lifetime decreases as HHF load is increased or coolant temperature is decreased.

  15. Plans of LHD divertor experiment

    International Nuclear Information System (INIS)

    Ohyabu, Nobuyoshi; Komori, Akio; Sagara, Akio; Noda, Nobuaki; Motojima, Osamu

    1996-01-01

    Scenarios of the LHD divertor experiment are presented. In the LHD divertor experimental program, various innovative divertor concepts and technologies, developed during its design phase will be utilized to improve the plasma performance. Two divertor operational scenarios (confinement improvement by generating high temperature divertor plasma and simultaneous achievement of radiative cooling and H-mode-like confinement improvement) are among them. Local island divertor geometry has also been proposed. This new divertor has been successfully tested in the CHS device and is planned to be installed in the LHD device. In addition, technological development of new efficient hydrogen pumping schemes (carbon sheet pump and membrane pump) are being pursued for enhancement of the divertor control capability. (author)

  16. Plasma flow in the DIII-D divertor

    International Nuclear Information System (INIS)

    Boedo, J.A.; Porter, G.D.; Schaffer, M.J.

    1998-07-01

    Indications that flows in the divertor can exhibit complex behavior have been obtained from 2-D modeling but so far remain mostly unconfirmed by experiment. An important feature of flow physics is that of flow reversal. Flow reversal has been predicted analytically and it is expected when the ionization source arising from neutral or impurity ionization in the divertor region is large, creating a high pressure zone. Plasma flows arise to equilibrate the pressure. A radiative divertor regime has been proposed in order to reduce the heat and particle fluxes to the divertor target plates. In this regime, the energy and momentum of the plasma are dissipated into neutral gas introduced in the divertor region, cooling the plasma by collisional, radiative and other atomic processes so that the plasma becomes detached from the target plates. These regimes have been the subject of extensive studies in DIII-D to evaluate their energy and particle transport properties, but only recently it has been proposed that the energy transport over large regions of the divertor must be dominated by convection instead of conduction. It is therefore important to understand the role of the plasma conditions and geometry on determining the region of convection-dominated plasma in order to properly control the heat and particle fluxes to the target plates and hence, divertor performance. The authors have observed complex structures in the deuterium ion flows in the DIII-D divertor. Features observed include reverse flow, convective flow over a large volume of the divertor and stagnant flow. They have measured large gradients in the plasma potential across the separatrix in the divertor and determined that these gradients induce poloidal flows that can potentially affect the particle balance in the divertor

  17. Innovations in the LHD divertor program

    International Nuclear Information System (INIS)

    Ohyabu, N.; Komori, A.; Noda, N.; Morisaki, T.; Sagara, A.; Suzuki, H.; Watanabe, T.; Motojima, O.; Takase, H.

    1995-01-01

    Various innovative divertor concepts have been developed to improve the LHD plasma performance. They are two divertor magnetic geometries (helical divertor configurations with and without n/m=1/1 island) and two operational scenarios (confinement improvement by generating high temperature divertor plasma and simultaneous achievement of radiative cooling and H-mode-like confinement improvement). In addition, technological development of new efficient hydrogen pumping schemes are being pursued for enhancing the divertor control capability. 16 refs., 4 figs

  18. Divertor cooling device

    International Nuclear Information System (INIS)

    Nakayama, Tadakazu; Hayashi, Katsumi; Handa, Hiroyuki

    1993-01-01

    Cooling water for a divertor cooling system cools the divertor, thereafter, passes through pipelines connecting the exit pipelines of the divertor cooling system and the inlet pipelines of a blanket cooling system and is introduced to the blanket cooling system in a vacuum vessel. It undergoes emission of neutrons, and cooling water in the divertor cooling system containing a great amount of N-16 which is generated by radioactivation of O-16 is introduced to the blanket cooling system in the vacuum vessel by way of pipelines, and after cooling, passes through exit pipelines of the blanket cooling system and is introduced to the outside of the vacuum vessel. Radiation of N-16 in the cooling water is decayed sufficiently with passage of time during cooling of the blanket, thereby enabling to decrease the amount of shielding materials such as facilities and pipelines, and ensure spaces. (N.H.)

  19. Fabrication of a 1200 kg Ingot of V-4Cr-4Ti for the DIII-D Radiative Divertor Program

    International Nuclear Information System (INIS)

    Johnson, W.R.; Smith, J.P.

    1998-01-01

    Vanadium chromium titanium alloys are attractive materials for fusion reactors because of their high temperature capability and their potential for low neutron active and rapid activation decay. A V-4Cr-4Ti alloy has been selected in the U.S. as the current leading candidate vanadium alloy for future use in fusion reactor structural applications. General Atomics (GA), in conjunction with the Department of Energy's (DOE) DIII-D Program, is carrying out a plan for the utilization of this vanadium alloy in the DIII-D tokamak. The plan will culminate in the fabrication, installation, and operation of a V-4Ti alloy structure in the DIII-D Radiative Divertor (RD) upgrade. The deployment of vanadium alloy will provide a meaningful step in the development and technology acceptance of this advanced material for future fusion power devices. Under a GA contract and material specification, an industrial scale 1200 kg heat (ingot) of a V-4Cr-4Ti alloy has been produced and converted into product forms by Wah Chang of Albany, Oregon (WCA). To assure the proper control of minor and trace impurities which affect the mechanical and activation behavior of this vanadium alloy, selected lots of raw vanadium base metal were processed by aluminothermic reduction of high purity vanadium oxide, and were then electron beam melted into two high purity vanadium ingots. The ingots were then consolidated with high purity Cr and Ti, and double vacuum-arc melted to obtain a 1200 kg V-4Cr-4Ti alloy ingot. Several billets were extruded from the ingot, and were then fabricated into plate, sheet, and rod at WCA. Tubing was subsequently processed from plate material. The chemistry and fabrication procedures for the product forms were specified on the basis of experience and knowledge gained from DOE Fusion Materials Program studies on previous laboratory scale heats and a large scale ingot (500 kg)

  20. Production and control of an edge radiating layer with the ergodic divertor on TORE SUPRA

    International Nuclear Information System (INIS)

    Poutchy, L.; Vallet, J.C.; Michelis, C. de; Grosman, A.; Hess, W.; Mattioli, M.; Monier-Garbet, P.

    1992-01-01

    We have recently defined on Tore Supra a discharge piloting strategy to prevent disruptions at the density limit, based on the property of the Ergodic Divertor to stabilize MHD activity. This strategy allows plasma studies close to the density limit without disruptions, and has been successfully used on Tore Supra ohmicly heated plasmas. The Ergodic Divertor allows also the stabilization of detached plasmas which appear spontaneously near the density limit. Edge impurities are shown to play a fundamental role in this stabilization. Detached plasmas have been thereby controlled during 10 seconds

  1. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D - Annual report input for 1996

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, W.R.; Smith, J.P.; Stambaugh, R.D.

    1996-10-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor (RD) upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy has been completed at Teledyne Wah Chang of Albany, Oregon (TWCA) to provide {approximately}800-kg of applicable product forms, and two billets have been extruded from the ingot. Chemical compositions of the ingot and both extruded billets were acceptable. Material from these billets will be converted into product forms suitable for components of the DIII-D Radiative Divertor structure. Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RD Program, and research into several joining methods for fabrication of the RD components, including resistance seam, friction, and electron beam welding, is continuing. Preliminary trials have been successful in the joining of V-alloy to itself by electron beam, resistance, and friction welding processes and to Inconel 625 by friction welding.

  2. Production and fabrication of vanadium alloys for the radiative divertor program of DIII-D - Annual report input for 1996

    International Nuclear Information System (INIS)

    Johnson, W.R.; Smith, J.P.; Stambaugh, R.D.

    1996-01-01

    V-4Cr-4Ti alloy has been selected for use in the manufacture of a portion of the DIII-D Radiative Divertor (RD) upgrade. The production of a 1200-kg ingot of V-4Cr-4Ti alloy has been completed at Teledyne Wah Chang of Albany, Oregon (TWCA) to provide ∼800-kg of applicable product forms, and two billets have been extruded from the ingot. Chemical compositions of the ingot and both extruded billets were acceptable. Material from these billets will be converted into product forms suitable for components of the DIII-D Radiative Divertor structure. Joining of V-4Cr-4Ti alloy has been identified as the most critical fabrication issue for its use in the RD Program, and research into several joining methods for fabrication of the RD components, including resistance seam, friction, and electron beam welding, is continuing. Preliminary trials have been successful in the joining of V-alloy to itself by electron beam, resistance, and friction welding processes and to Inconel 625 by friction welding

  3. Effect of separatrix magnetic geometry on divertor behavior in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, T.W., E-mail: petrie@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Canik, J.M. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Leonard, A.W.; Mahdavi, M.A. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Watkins, J.G. [Sandia National Laboratories, P.O. Box 5800, Albuquerque, NM 87185 (United States); Fenstermacher, M.E. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Ferron, J.R.; Groebner, R.J. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Hill, D.N. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Hyatt, A.W. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Holcomb, C.T. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Luce, T.C. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States); Moyer, R.A. [University of California–San Diego, La Jolla, CA 92093-0417 (United States); Stangeby, P.C. [University of Toronto Institute of Aerospace Studies, Toronto (Canada)

    2013-07-15

    We report on recent experiments on DIII-D that examined the effects that variations in the parallel connection length in the scrape-off layer (SOL), L{sub ||}, and the radial location of the outer divertor target, R{sub TAR}, have on divertor plasma properties. Two-point modeling of the SOL plasma predicts that larger values of L{sub ||} and R{sub TAR} should lower temperature and raise density at the outer divertor target for fixed upstream separatrix density and temperature, i.e., n{sub TAR} ∝ [R{sub TAR}]{sup 2}[L{sub ||}]{sup 6/7} and T{sub TAR} ∝ [R{sub TAR}]{sup −2}[L{sub ||}]{sup −4/7}. The dependence of n{sub TAR} and T{sub TAR} on L{sub ||} was consistent with our data, but the dependence of n{sub TAR} and T{sub TAR} on R{sub TAR} was not. The surprising result that the divertor plasma parameters did not depend on R{sub TAR} in the predicted way may be due to convected heat flux, driven by escaping neutrals, in the more open configuration of the larger R{sub TAR} cases. Modeling results using the SOLPS code support this postulate.

  4. VUV Spectroscopy in DIII-D Divertor

    International Nuclear Information System (INIS)

    Alkesh Punjabi; Nelson Jalufka

    2004-01-01

    The research carried out on this grant was motivated by the high power emission from the CIV doublet at 155 nm in the DIII-D divertor and to study the characteristics of the radiative divertor. The radiative divertor is designed to reduce the heat load to the target plates of the divertor by reducing the energy in the divertor plasma using upstream scrape-off-layer (SOL) radiation. In some cases, particularly in Partially Detached Divertor (PDD) operations, this emission accounts for more than 50% of the total radiation from the divertor. In PDD operation, produced by neutral gas injection, the particle flow to the target plate and the divertor temperature are significantly reduced. A father motivation was to study the CIV emission distribution in the lower, open divertor and the upper baffled divertor. Two Vacuum Ultra Violet Tangential viewing Television cameras (VUV TTV) were constructed and installed in the upper, baffled and the lower, open divertor. The images recorded by these cameras were then inverted to produce two-dimensional distributions of CIV in the poloidal plane. Results obtained in the project are summarized in this report

  5. Investigation of electron parallel pressure balance in the scrape-off layer of deuterium-based radiative divertor discharges IN DIII-D

    International Nuclear Information System (INIS)

    Petrie, T.W.; Carlstrom, T.N.; Allen, S.L.

    1996-10-01

    Electron density, temperature, and parallel pressure measurements at several locations along field lines connecting the midplane scrapeoff layer (SOL) with the outer divertor are presented for both attached and partially-detached divertor cases: I p = 1.4 MA, q 95 = 4.2, and P input ∼ 6.7 MW under ELMing H-mode conditions. At the onset of the Partially Detached Divertor (PDD), a high density, low temperature plasma forms in the divertor SOL (divertor MARFE). The electron pressure drops by a factor of ∼ 2 between the midplane separatrix and the X-point, and then an additional ∼3--5 times between the X-point and the outboard separatrix strike point. These results are in contrast to the attached (non-PDD) case, where electron pressure in the SOL is reduced by, at most, a factor of two between the midplane and the divertor target. Divertor MARFEs generally have only marginal adverse impact on important H-mode characteristics, such as confinement time. In fact, PDD discharges at low input power maintains good H-mode characteristics until a high density, low temperature plasma abruptly forms inside the separatrix near the X-point (X-point MARFE). Concurrent with the appearance of this X-point MARFE is a degradation in both energy confinement and the plasma fueling rate, and an increase in the carbon impurity concentration inside the core plasma. The formation of the X-point MARFE is consistent with a thermal instability resulting from the temperature dependence of the carbon radiative cooling rate in the range ∼ 7--30 eV

  6. Metallurgical Bonding Development of V-4Cr-4Ti Alloy for the DIII-D Radiative Divertor Program

    International Nuclear Information System (INIS)

    Smith, J.P.; Johnson, W.R.; Trester, P.W.

    1998-01-01

    General Atomics (GA), in conjunction with the Department of Energy's (DOE) DIII-D Program, is carrying out a plan to utilize a vanadium alloy in the DIII-D tokamak as part of the DIII-D Radiative Divertor (RD) upgrade. The V-4Cr-4Ti alloy has been selected in the U.S. as the leading candidate vanadium alloy for fusion applications. This alloy will be used for the divertor fabrication. Manufacturing development with the V-4Cr-4Ti alloy is a focus of the DIII-D RD Program. The RD structure, part of which will be fabricated from V-4Cr-4Ti alloy, will require many product forms and types of metal/metal bonded joints. Metallurgical bonding methods development on this vanadium alloy is therefore a key area of study by GA. Several solid state (non-fusion weld) and fusion weld joining methods are being investigated. To date, GA has been successful in producing ductile, high strength, vacuum leak tight joints by all of the methods under investigation. The solid state joining was accomplished in air, i.e., without the need for a vacuum or inert gas environment to prevent interstitial impurity contamination of the V-4Cr-4Ti alloy

  7. Structural impact of armor monoblock dimensions on the failure behavior of ITER-type divertor target components: Size matters

    Energy Technology Data Exchange (ETDEWEB)

    Li, Muyuan; You, Jeong-Ha, E-mail: you@ipp.mpg.de

    2016-12-15

    Highlights: • Quantitative assessment of size effects was conducted numerically for W monoblock. • Decreasing the width of W monoblock leads to a lower risk of failure. • The Cu interlayer was not affected significantly by varying armor thickness. • The predicted trends were in line with the experimental observations. - Abstract: Plenty of high-heat-flux tests conducted on tungsten monoblock type divertor target mock-ups showed that the threshold heat flux density for cracking and fracture of tungsten armor seems to be related to the dimension of the monoblocks. Thus, quantitative assessment of such size effects is of practical importance for divertor target design. In this paper, a computational study about the thermal and structural impact of monoblock size on the plastic fatigue and fracture behavior of an ITER-type tungsten divertor target is reported. As dimensional parameters, the width and thickness of monoblock, the thickness of sacrificial armor, and the inner diameter of cooling tube were varied. Plastic fatigue lifetime was estimated for the loading surface of tungsten armor and the copper interlayer by use of a cyclic-plastic constitutive model. The driving force of brittle crack growth through the tungsten armor was assessed in terms of J-integral at the crack tip. Decrease of the monoblock width effectively reduced accumulation of plastic strain at the armor surface and the driving force of brittle cracking. Decrease of sacrificial armor thickness led to decrease of plastic deformation at the loading surface due to lower surface temperature, but the thermal and mechanical response of the copper interlayer was not affected by the variation of armor thickness. Monoblock with a smaller tube diameter but with the same armor thickness and shoulder thickness experienced lower fatigue load. The predicted trends were in line with the experimental observations.

  8. The ITER divertor concept

    International Nuclear Information System (INIS)

    Janeschitz, G.; Borrass, K.; Federici, G.; Igitkhanov, Y.; Kukushkin, A.; Pacher, H.D.; Pacher, G.W.; Sugihara, M.

    1995-01-01

    The ITER divertor must exhaust most of the alpha particle power and the He ash at acceptable erosion rates. The high recycling regime of the ITER-CDA for present parameters would yield high power loads and erosion rates on conventional targets. Improvement by radiation in the SOL at constant pressure is limited in principle. To permit a higher radiation fraction, the plasma pressure along the field must be reduced by more than a factor 10, reducing also the target ion flux. This pressure reduction can be obtained by strong plasma-neutral interaction below the X-point. Under these conditions T e in the divertor can be reduced to <5 eV along a flame like ionisation front by impurity radiation and CX losses. Downstream of the front, neutrals undergo more CX or i-n collisions than ionisation events, resulting in significant momentum loss via neutrals to the divertor chamber wall. The pressure reduction by this mechanism depends on the along-field length for neutral-plasma interaction, the parallel power flux, the neutral density, the ratio of neutral-neutral collision length to the plasma-wall distance and on the Mach number of ions and neutrals. A supersonic transition in the main plasma-neutral interaction region, expected to occur near the ionisation front, would be beneficial for momentum removal. The momentum transfer fraction to the side walls is calculated: low Knudsen number is beneficial. The impact of the different physics effects on the chosen geometry and on the ITER divertor design and the lifetime of the various divertor components are discussed. ((orig.))

  9. Snowflake divertor configuration studies for NSTX-Upgrade

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.

    2011-01-01

    Snowflake divertor experiments in NSTX provide basis for PMI development toward NSTX-Upgrade. Snowflake configuration formation was followed by radiative detachment. Significant reduction of steady-state divertor heat flux observed in snowflake divertor. Impulsive heat loads due to Type I ELMs are partially mitigated in snowflake divertor. Magnetic control of snowflake divertor configuration is being developed. Plasma material interface development is critical for NSTX-U success. Four divertor coils should enable flexibility in boundary shaping and control in NSTX-U. Snowflake divertor experiments in NSTX provide good basis for PMI development in NSTX-Upgrade. FY 2009-2010 snowflake divertor experiments in NSTX: (1) Helped understand control of magnetic properties; (2) Core H-mode confinement unchanged; (3) Core and edge carbon concentration reduced; and (4) Divertor heat flux significantly reduced - (a) Steady-state reduction due to geometry and radiative detachment, (b) Encouraging results for transient heat flux handling, (c) Combined with impurity-seeded radiative divertor. Outlook for snowflake divertor in NSTX-Upgrade: (1) 2D fluid modeling of snowflake divertor properties scaling - (a) Edge and divertor transport, radiation, detachment threshold, (b) Compatibility with cryo-pump and lithium conditioning; (2) Magnetic control development; and (3) PFC development - PFC alignment and PFC material choice.

  10. Advanced divertor configurations with large flux expansion

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V.A., E-mail: vlad@llnl.gov [Lawrence Livermore National Laboratory, Livermore, CA (United States); Bell, R.E.; Diallo, A.; Gerhardt, S.; Kaye, S.; Kolemen, E.; LeBlanc, B.P. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); McLean, A. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Menard, J.E.; Paul, S.F.; Podesta, M. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Raman, R. [University of Washington, Seattle, WA (United States); Ryutov, D.D. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Scotti, F.; Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Maingi, R. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Mueller, D.M.; Roquemore, A.L. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Reimerdes, H.; Canal, G.P. [Ecole Polytechnique Fédérale de Lausanne, Centre de Recherches en Physique des Plasmas, Association Euratom Confédération Suisse, Lausanne (Switzerland); and others

    2013-07-15

    Experimental studies of the novel snowflake divertor concept (D. Ryutov, Phys. Plasmas 14 (2007) 064502) performed in the NSTX and TCV tokamaks are reviewed in this paper. The snowflake divertor enables power sharing between divertor strike points, as well as the divertor plasma-wetted area, effective connection length and divertor volumetric power loss to increase beyond those in the standard divertor, potentially reducing heat flux and plasma temperature at the target. It also enables higher magnetic shear inside the separatrix, potentially affecting pedestal MHD stability. Experimental results from NSTX and TCV confirm the predicted properties of the snowflake divertor. In the NSTX, a large spherical tokamak with a compact divertor and lithium-coated graphite plasma-facing components (PFCs), the snowflake divertor operation led to reduced core and pedestal impurity concentration, as well as re-appearance of Type I ELMs that were suppressed in standard divertor H-mode discharges. In the divertor, an otherwise inaccessible partial detachment of the outer strike point with an up to 50% increase in divertor radiation and a peak divertor heat flux reduction from 3–7 MW/m{sup 2} to 0.5–1 MW/m{sup 2} was achieved. Impulsive heat fluxes due to Type-I ELMs were significantly dissipated in the high magnetic flux expansion region. In the TCV, a medium-size tokamak with graphite PFCs, several advantageous snowflake divertor features (cf. the standard divertor) have been demonstrated: an unchanged L–H power threshold, enhanced stability of the peeling–ballooning modes in the pedestal region (and generally an extended second stability region), as well as an H-mode pedestal regime with reduced (×2–3) Type I ELM frequency and slightly increased (20–30%) normalized ELM energy, resulting in a favorable average energy loss comparison to the standard divertor. In the divertor, ELM power partitioning between snowflake divertor strike points was demonstrated. The NSTX

  11. Development of divertor remote maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Nobukazu; Oka, Kiyoshi; Akou, Kentaro; Takiguchi, Yuji [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    The ITER divertor is categorized as a scheduled maintenance component because of extreme heat and particle loads it is exposed to by plasma. It is also highly activated by 14 MeV neutrons. Reliable remote handling equipment and tools are required for divertor maintenance under intense gamma radiation. To facilitate remote maintenance, the divertor is segmented into 60 cassettes, and each cassette weighing about 25 tons and maintained and replaced through four maintenance ports each 90 degrees. Divertor cassettes must be transported toroidally and radially for replacement through maintenance ports. Remote handling involving cassette movers and carriers for toroidal and radial transport has been developed. Under the ITER R and D program, technology critical to divertor cassette maintenance is being developed jointly by Japan, E.U., and U.S. home teams. This paper summarizes divertor remote maintenance design and the status of technology development by the Japan Home Team. (author)

  12. Development of divertor remote maintenance system

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Oka, Kiyoshi; Akou, Kentaro; Takiguchi, Yuji

    1998-01-01

    The ITER divertor is categorized as a scheduled maintenance component because of extreme heat and particle loads it is exposed to by plasma. It is also highly activated by 14 MeV neutrons. Reliable remote handling equipment and tools are required for divertor maintenance under intense gamma radiation. To facilitate remote maintenance, the divertor is segmented into 60 cassettes, and each cassette weighing about 25 tons and maintained and replaced through four maintenance ports each 90 degrees. Divertor cassettes must be transported toroidally and radially for replacement through maintenance ports. Remote handling involving cassette movers and carriers for toroidal and radial transport has been developed. Under the ITER R and D program, technology critical to divertor cassette maintenance is being developed jointly by Japan, E.U., and U.S. home teams. This paper summarizes divertor remote maintenance design and the status of technology development by the Japan Home Team. (author)

  13. Divertor scenario development for NSTX Upgrade

    Science.gov (United States)

    Soukhanovskii, V. A.; McLean, A. G.; Meier, E. T.; Rognlien, T. D.; Ryutov, D. D.; Bell, R. E.; Diallo, A.; Gerhardt, S. P.; Kaita, R.; Kolemen, E.; Leblanc, B. P.; Menard, J. E.; Podesta, M.; Scotti, F.

    2012-10-01

    In the NSTX-U tokamak, initial plans for divertor plasma-facing components (PFCs) include lithium and boron coated graphite, with a staged transition to molybdenum. Steady-state peak divertor heat fluxes are projected to reach 20-30 MW/m^2 in 2 MA, 12 MW NBI-heated discharges of up to 5 s duration, thus challenging PFC thermal limits. Based on the recent NSTX divertor experiments and modeling with edge transport code UEDGE, a favorable basis for divertor power handling in NSTX-U is developed. The snowflake divertor geometry and feedback-controlled divertor impurity seeding applied to the lower and upper divertors are presently envisioned. In the NSTX snowflake experiments with lithium-coated graphite PFCs, the peak divertor heat fluxes from Type I ELMs and between ELMs were significantly reduced due to geometry effects, increased volumetric losses and null-point convective redistribution between strike points. H-mode core confinement was maintained at H98(y,2)<=1 albeit the radiative detachment. Additional CD4 seeding demonstrated potential for a further increase of divertor radiation.

  14. Detached divertor plasmas in JET

    Energy Technology Data Exchange (ETDEWEB)

    Horton, L D; Borrass, K; Corrigan, G; Gottardi, N; Lingertat, J; Loarte, A; Simonini, R; Stamp, M F; Taroni, A [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Stangeby, P C [Toronto Univ., ON (Canada). Inst. for Aerospace Studies

    1994-07-01

    In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

  15. Divertor characterization experiments

    International Nuclear Information System (INIS)

    Porter, G.D.; Allen, S.; Fenstermacher, M.; Hill, D.; Brown, M.; Jong, R.A.; Rognlien, T.; Rensink, M.; Smith, G.; Stambaugh, R.; Mahdavi, M.A.; Leonard, A.; West, P., Evans, T.

    1996-01-01

    Recent DIII-D experiments with enhanced Scrape-off Layer (SOL) diagnostics permit detailed characterization of the SOL and divertor plasma under various operating conditions. We observe two distinct plasma modes: attached and detached divertor plasmas. Detached plasmas are characterized by plate temperatures of only 1 to 2 eV. Simulation of detached plasmas using the UEDGE code indicate that volume recombination and charge exchange play an important role in achieving detachment. When the power delivered to the plate is reduced by enhanced radiation to the point that recycled neutrals can no longer be efficiently ionized, the plate temperature drops from around 10 eV to 1-2 eV. The low temperature region extends further off the plate as the power continues to be reduced, and charge exchange processes remove momentum, reducing the plasma flow. Volume recombination becomes important when the plasma flow is reduced sufficiently to permit recombination to compete with flow to the plate

  16. Snowflake divertor configuration studies in National Spherical Torus Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V. A.; McLean, A. G.; Rognlien, T. D.; Ryutov, D. D.; Umansky, M. V. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Bell, R. E.; Diallo, A.; Gerhardt, S.; Kaye, S.; Kolemen, E.; LeBlanc, B. P.; Menard, J. E.; Paul, S. F.; Podesta, M.; Roquemore, A. L.; Scotti, F.; Battaglia, D.; Bell, M. G.; Gates, D. A.; Kaita, R. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); and others

    2012-08-15

    Experimental results from NSTX indicate that the snowflake divertor (D. Ryutov, Phys. Plasmas 14, 064502 (2007)) may be a viable solution for outstanding tokamak plasma-material interface issues. Steady-state handling of divertor heat flux and divertor plate erosion remains to be critical issues for ITER and future concept devices based on conventional and spherical tokamak geometry with high power density divertors. Experiments conducted in 4-6 MW NBI-heated H-mode plasmas in NSTX demonstrated that the snowflake divertor is compatible with high-confinement core plasma operation, while being very effective in steady-state divertor heat flux mitigation and impurity reduction. A steady-state snowflake divertor was obtained in recent NSTX experiments for up to 600 ms using three divertor magnetic coils. The high magnetic flux expansion region of the scrape-off layer (SOL) spanning up to 50% of the SOL width {lambda}{sub q} was partially detached in the snowflake divertor. In the detached zone, the heat flux profile flattened and decreased to 0.5-1 MW/m{sup 2} (from 4-7 MW/m{sup 2} in the standard divertor) indicative of radiative heating. An up to 50% increase in divertor, P{sub rad} in the snowflake divertor was accompanied by broadening of the intrinsic C III and C IV radiation zones, and a nearly order of magnitude increase in divertor high-n Balmer line emission indicative of volumetric recombination onset. Magnetic reconstructions showed that the x-point connection length, divertor plasma-wetted area and divertor volume, all critical parameters for geometric reduction of deposited heat flux, and increased volumetric divertor losses were significantly increased in the snowflake divertor, as expected from theory.

  17. Radiation: behavioral implications in space

    International Nuclear Information System (INIS)

    Bogo, V.

    1988-01-01

    Since future space missions are likely to be beyond Earth's protective atmosphere, a potentially significant hazard is radiation. The following behavioural situations are addressed in this paper: (1) space radiations are more effective at disrupting behaviour; (2) task demands can aggravate the radiation-disruption; (3) efforts to mitigate disruption with drugs or shielding are not satisfactory and the drugs can be behaviourally toxic; and (4) space- and radiation-induced emesis combined may be synergistic. Thus future space travel will be a demanding, exciting time for behavioral toxicologists, and while the circumstances may seem insurmountable at first, creative application of scientific expertise should illicit solutions, similar to demanding situations confronted before. (author)

  18. Dissipative divertor operation in the Alcator C-Mod tokamak

    International Nuclear Information System (INIS)

    Lipschultz, B.; Goetz, J.; LaBombard, B.; McCracken, G.M.; Terry, J.L.; Graf, M.; Granetz, R.S.; Jablonski, D.; Kurz, C.; Niemczewski, A.; Snipes, J.

    1995-01-01

    The achievement of large volumetric power losses (dissipation) in the Alcator C-Mod divertor region is demonstrated in two operational modes: radiative divertor and detached divertor. During radiative divertor operation, the fraction of SOL power lost by radiation is P R /P SOL ∼0.8 with single null plasmas, n e 20 m -3 and I p e,div ≤6x10 20 m -3 . As the divertor radiation and density increase, the plasma eventually detaches abruptly from the divertor plates: I SAT drops at the target and the divertor radiation peak moves to the X-point region. Probe measurements at the divertor plate show that the transition occurs when T e ∼5 eV. The critical n e for detachment depends linearly on the input power. This abrupt divertor detachment is preceded by a comparatively long period ( similar 1-200 ms) where a partial detachment is observed to grow at the outer divertor plate. ((orig.))

  19. Divertor development for a future fusion power plant

    International Nuclear Information System (INIS)

    Norajitra, Prachai

    2011-01-01

    Nuclear fusion is considered as a future source of sustainable energy supply. In the first chapter, the physical principle of magnetic plasma confinement, and the function of a tokamak are described. Since the discovery of the H-mode in ASDEX experiment ''Divertor I'' in 1982, the divertor has been an integral part of all modern tokamaks and stellarators, not least the ITER machine. The goal of this work is to develop a feasible divertor design for a fusion power plant to be built after ITER. This task is particularly challenging because a fusion power plant formulates much greater demands on the structural material and the design than ITER in terms of neutron wall load and radiation. First several divertor concepts proposed in the literature e.g. the Power Plant Conceptual Study (PPCS) using different coolants are reviewed and analyzed with respect to their performance. As a result helium cooled divertor concept exhibited the best potential to come up to the highest safety requirements and therefore has been chosen for the design process. From the third chapter the necessary steps towards this goal are described. First, the boundary conditions for the arrangement of a divertor with respect to the fusion plasma are discussed, as this determines the main thermal and neutronic load parameters. Based on the loads material selection criteria are inherently formulated. In the next step, the reference design is defined in accordance with the established functional design specifications. The developed concept is of modular nature and consists of cooling fingers of tungsten using an impingement cooling in order to achieve a heat dissipation of 10 MW/m 2 . In the next step, the design was subjected to the thermal-hydraulic and thermo-mechanical calculations in order to analyze and improve the performance and the manufacturing technologies. Based on these results, a prototype was produced and experimentally tested on their cooling capacity, their thermo-cyclic loading

  20. Radiation behavior of superconductors

    International Nuclear Information System (INIS)

    Scanlan, R.M.; Raymond, E.L.

    1979-01-01

    High energy neutron irradiations have been performed on Nb 3 Sn superconductors to assess their behavior in a fusion reactor environment. Irradiations were performed at 4.2 K and property measurements were made without warming the samples. The critical current I/sub c/ increased with irradiation to a level about 50% above the unirradiated value at the highest fluences reached in our experiments. These results are compared with the results of other low temperature irradiations of Nb 3 Sn

  1. Numerical exploration of non-axisymmetric divertor closure in the small angle slot (SAS) divertor at DIII-D

    Science.gov (United States)

    Frerichs, H.; Schmitz, O.; Covele, B.; Feng, Y.; Guo, H. Y.; Hill, D.

    2018-05-01

    Numerical simulations of toroidal asymmetries in a tightly baffled small angle slot (SAS) divertor on the DIII-D tokamak show that toroidal asymmetries in divertor closure result in (non-axisymmetric) local onset of detachment within a density window of 10-15% on top of the nominal threshold separatrix density. The SAS divertor is explored at DIII-D for improving access to cold, dissipative/detached divertor conditions. The narrow width of the slot divertor coupled with a small magnetic field line-to-target angle facilitates the buildup of neutral density, thereby increasing radiative and neutrals-related (atoms and molecules) losses in the divertor. Small changes in the strike point location can be expected to have a large impact on divertor conditions. The combination of misaligned slot structure and non-axisymmetric perturbations to the magnetic field configuration causes the strike point to move along the divertor target plate, possibly leaving the divertor slot at some locations. The latter extreme case essentially introduces an opening in the divertor slot from where recycling neutrals can easily escape, and thereby degrade the performance of the slot divertor. Such a strike point dislocation is approximated by a finite gap in the divertor baffle for which 3D edge plasma and neutral gas simulations are performed with the EMC3-EIRENE code.

  2. The effect of density on divertor conditions in ASDEX-Upgrade

    International Nuclear Information System (INIS)

    Pitcher, C.S.; Bosch, H.-S.; Buechl, K.; Field, A.; Fuchs, C.; Haas, G.; Junker, W.; Neu, R.; Neuhauser, J.; Wenzel, U.

    1995-01-01

    Detailed experimental divertor data are presented on the profiles of density and temperature in the inner and outer divertor fans, the radiated power distribution, the gas pressure and the spectroscopically derived particle fluxes, all as a function of the discharge density. At low and medium density, the inner divertor is cold and dense compared to the outer divertor. At high density, strong X-point MARFE and separatrix radiation partially detaches the inner divertor. Probe measurements which penetrate into the X-point MARFE at the outer divertor are presented. ((orig.))

  3. Conceptual design of CFETR divertor remote handling compatible structure

    International Nuclear Information System (INIS)

    Dai, Huaichu; Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei

    2016-01-01

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  4. Conceptual design of CFETR divertor remote handling compatible structure

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Huaichu, E-mail: yaodm@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); University of Science and Technology of China, Hefei (China); Yao, Damao; Cao, Lei; Zhou, Zibo; Li, Lei [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2016-11-15

    Highlights: • Conceptual design for the CFETR divertor have been proposed, especially the divertor remote handling compatible structure. • The degrees of freedom of the divertor are analyzed in order to validate the design the divertor supports structure. • Besides the ITER-like scheme, a new scheme for the divertor remote handling compatible supports is proposed, that is the rack and pinion mechanism. • The installation/removel process is verified through simulation in Delmia in order to check design quality for remote handling requirements. - Abstract: Divertor is one of key components of tokamak fusion reactor. The CFETR is China Fusion Engineering Test Reactor. Its divertor will expose to tritium environment and neutron radiation. Materials of the divertor will be radioactived, and cannot be handled by personnel directly. To develop structure which compatible with robots handle for installation, maintenance and removing is required. This paper introduces a conceptual design of CFETR divertor module which compatible with remote handling end-effectors. The divertor module is confined by inner and outer support. The inner support is only confined divertor module radial, toroidal and vertical moving freedom degrees, but not confined rotating freedom degrees. The outer support is the structure that can confine rotating freedom degrees and should also be compatible with remote handling end-effectors.

  5. Low energy neutral particle fluxes in the JET divertor

    International Nuclear Information System (INIS)

    Reichle, R.; Horton, L.D.; Ingesson, L.C.; Jaeckel, H.J.; McCormick, G.K.; Loarte, A.; Simonini, R.; Stamp, M.F.

    1997-01-01

    First measurements are presented of the total power loss through neutral particles and their average energy in the JET divertor. The method used distinguishes between the heat flux and the electromagnetic radiation on bolometers. This is done by comparing measurements from inside the divertor either with opposite lines of sight or with a tomographic reconstruction of the radiation. The typical value of the total power loss in the divertor through neutrals is about 1 MW. The average energy of the neutral particles at the inner divertor leg is 1.5-3 eV when detachment is in progress, which agrees with EDGE2D/NIMBUS modelling. (orig.)

  6. Divertor plasma studies on DIII-D: Experiment and modeling

    International Nuclear Information System (INIS)

    West, W.P.; Brooks, N.H.; Allen, S.L.

    1996-09-01

    In a magnetically diverted tokamak, the scrape-off layer (SOL) and divertor plasma provides separation between the first wall and the core plasma, intercepting impurities generated at the wall before they reach the core plasma. The divertor plasma can also serve to spread the heat and particle flux over a large area of divertor structure wall using impurity radiation and neutral charge exchange, thus reducing peak heat and particle fluxes at the divertor strike plate. Such a reduction will be required in the next generation of tokamaks, for without it, the divertor engineering requirements are very demanding. To successfully demonstrate a radiative divertor, a highly radiative condition with significant volume recombination must be achieved in the divertor, while maintaining a low impurity content in the core plasma. Divertor plasma properties are determined by a complex interaction of classical parallel transport, anomalous perpendicular transport, impurity transport and radiation, and plasma wall interaction. In this paper the authors describe a set of experiments on DIII-D designed to provide detailed two dimensional documentation of the divertor and SOL plasma. Measurements have been made in operating modes where the plasma is attached to the divertor strike plate and in highly radiating cases where the plasma is detached from the divertor strike plate. They also discuss the results of experiments designed to influence the distribution of impurities in the plasma using enhanced SOL plasma flow. Extensive modeling efforts will be described which are successfully reproducing attached plasma conditions and are helping to elucidate the important plasma and atomic physics involved in the detachment process

  7. Divertors for Helical Devices: Concepts, Plans, Results, and Problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2004-01-01

    With Large Helical Device (LHD) and Wendelstein 7-X (W7-X), the development of helical devices is now taking a large step forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large machines were prepared in smaller-scale devices like Heliotron E, Compact Helical System (CHS), and Wendelstein 7-AS (W7-AS). While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller-scale experiments like Heliotron-J, CHS, and National Compact Stellarator Experiment will be used for the further development of divertor concepts. The two divertor configurations that are being investigated are the helical and the island divertor, as well as the local island divertor, which was successfully demonstrated on CHS and just went into operation on LHD. At present, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor that will allow quasi-continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi-steady-state operating scenario in a newly found high-density H-mode operating regime, which benefits from high energy and low impurity confinement times, with edge radiation levels of up to 90% and sufficient neutral compression in the subdivertor region (>10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios, toroidal asymmetries due to symmetry breaking error fields

  8. Divertors for helical devices: Concepts, plans, results and problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2003-01-01

    With LHD and W7-X stellarator development is now taking a large leap forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control, and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large stellarators were carefully prepared in smaller scale devices like Heliotron E, CHS and W7-AS. While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller scale experiments like Heliotron-J, CHS and NCSX will be used for the further development of divertor concepts. The two divertor configurations that are presently being investigated, are the helical and the island divertor, as well as the local island divertor (LID), which was successfully demonstrated on CHS and just went into operation on LHD. Presently, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor which will allow quasi continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi steady-state operating scenario in a newly found high density H-mode operating regime, which benefits from high energy and extremely low impurity confinement times, with edge radiation levels of up to 90 % and sufficient neutral compression in the subdivertor region (> 10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios and toroidal asymmetries due to symmetry breaking error fields, etc. will be discussed. (orig.)

  9. Divertor heat flux mitigation in the National Spherical Torus Experimenta)

    Science.gov (United States)

    Soukhanovskii, V. A.; Maingi, R.; Gates, D. A.; Menard, J. E.; Paul, S. F.; Raman, R.; Roquemore, A. L.; Bell, M. G.; Bell, R. E.; Boedo, J. A.; Bush, C. E.; Kaita, R.; Kugel, H. W.; Leblanc, B. P.; Mueller, D.; NSTX Team

    2009-02-01

    Steady-state handling of divertor heat flux is a critical issue for both ITER and spherical torus-based devices with compact high power density divertors. Significant reduction of heat flux to the divertor plate has been achieved simultaneously with favorable core and pedestal confinement and stability properties in a highly shaped lower single null configuration in the National Spherical Torus Experiment (NSTX) [M. Ono et al., Nucl. Fusion 40, 557 2000] using high magnetic flux expansion at the divertor strike point and the radiative divertor technique. A partial detachment of the outer strike point was achieved with divertor deuterium injection leading to peak flux reduction from 4-6MWm-2to0.5-2MWm-2 in small-ELM 0.8-1.0MA, 4-6MW neutral beam injection-heated H-mode discharges. A self-consistent picture of the outer strike point partial detachment was evident from divertor heat flux profiles and recombination, particle flux and neutral pressure measurements. Analytic scrape-off layer parallel transport models were used for interpretation of NSTX detachment experiments. The modeling showed that the observed peak heat flux reduction and detachment are possible with high radiated power and momentum loss fractions, achievable with divertor gas injection, and nearly impossible to achieve with main electron density, divertor neutral density or recombination increases alone.

  10. Integrated core-edge-divertor modeling studies

    International Nuclear Information System (INIS)

    Stacey, W.M.

    2001-01-01

    An integrated calculation model for simulating the interaction of physics phenomena taking place in the plasma core, in the plasma edge and in the SOL and divertor of tokamaks has been developed and applied to study such interactions. The model synthesises a combination of numerical calculations (1) the power and particle balances for the core plasma, using empirical confinement scaling laws and taking into account radiation losses (2), the particle, momentum and power balances in the SOL and divertor, taking into account the effects of radiation and recycling neutrals, (3) the transport of feeling and recycling neutrals, explicitly representing divertor and pumping geometry, and (4) edge pedestal gradient scale lengths and widths, evaluation of theoretical predictions (5) confinement degradation due to thermal instabilities in the edge pedestals, (6) detachment and divertor MARFE onset, (7) core MARFE onsets leading to a H-L transition, and (8) radiative collapse leading to a disruption and evaluation of empirical fits (9) power thresholds for the L-H and H-L transitions and (10) the width of the edge pedestals. The various components of the calculation model are coupled and must be iterated to a self-consistent convergence. The model was developed over several years for the purpose of interpreting various edge phenomena observed in DIII-D experiments and thereby, to some extent, has been benchmarked against experiment. Because the model treats the interactions of various phenomena in the core, edge and divertor, yet is computationally efficient, it lends itself to the investigation of the effects of different choices of various edge plasma operating conditions on overall divertor and core plasma performance. Studies of the effect of feeling location and rate, divertor geometry, plasma shape, pumping and over 'edge parameters' on core plasma properties (line average density, confinement, density limit, etc.) have been performed for DIII-D model problems. A

  11. Developing physics basis for the snowflake divertor in the DIII-D tokamak

    Science.gov (United States)

    Soukhanovskii, V. A.; Allen, S. L.; Fenstermacher, M. E.; Lasnier, C. J.; Makowski, M. A.; McLean, A. G.; Meyer, W. H.; Ryutov, D. D.; Kolemen, E.; Groebner, R. J.; Hyatt, A. W.; Leonard, A. W.; Osborne, T. H.; Petrie, T. W.; Watkins, J.

    2018-03-01

    Recent DIII-D results demonstrate that the snowflake (SF) divertor geometry (see standard divertor) enables significant manipulation of divertor heat transport for heat spreading and reduction in attached and radiative divertor regimes, between and during edge localized modes (ELMs), while maintaining good H-mode confinement. Snowflake divertor configurations have been realized in the DIII-D tokamak for several seconds in H-mode discharges with heating power P_NBI ≤slant 4 -5 MW and a range of plasma currents I_p=0.8-1.2 MA. In this work, inter-ELM transport and radiative SF divertor properties are studied. Significant impact of geometric properties on SOL and divertor plasma parameters, including increased poloidal magnetic flux expansion, divertor magnetic field line length and divertor volume, is confirmed. In the SF-minus configuration, heat deposition is affected by the geometry, and peak divertor heat fluxes are significantly reduced. In the SF-plus and near-exact SF configurations, divertor peak heat flux reduction and outer strike point heat flux profile broadening are observed. Inter-ELM sharing of power and particle fluxes between the main and additional snowflake divertor strike points has been demonstrated. The additional strike points typically receive up to 10-15% of total outer divertor power. Measurements of electron pressure and poloidal beta βp support the theoretically proposed churning mode that is driven by toroidal curvature and vertical pressure gradient in the weak poloidal field region. A comparison of the 4-4.5 MW NBI-heated H-mode plasmas with radiative SF divertor and the standard radiative divertor (both induced with additional gas puffing) shows a nearly complete power detachment and broader divertor radiated power distribution in the SF, as compared to a partial detachment and peaked localized radiation in the standard divertor. However, insignificant difference in the detachment onset w.r.t. density between the SF and the standard

  12. Surface mechanical attrition treatment of tungsten and its behavior under low energy deuterium plasma implantation relevant to ITER divertor conditions

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H.Y.; Yuan, Y.; Fu, B.Q.; Godfrey, A.; Liu, W. [Tsinghua Univ.. Lab. of Advanced Materials, Beijing (China); Zhang, Y.B. [Technical Univ. og Denmark. DTU Risoe Campus, Roskilde (Denmark); Tao, N.R. [Chinese Academy of Sciences, Shenyang (China)

    2012-11-01

    In the light of a foreseen application for tungsten (W) as an ITER divertor material samples have been plastically deformed by a surface mechanical attrition treatment (SMAT) and by cold rolling. The resistance to blister formation by low energy deuterium implantation in these samples has been examined, with the result that the structure is significantly improved as the structural scale is reduced to the nanometer range in the SMAT sample. The distribution of blisters in this sample is however bimodal, due to the formation of several very large blisters, which are heterogeneously distributed. The observations suggest that process optimization must be a next step in the development with a view to the application of plastically deformed W in a fusion reactor. (Author)

  13. Models for poloidal divertors

    International Nuclear Information System (INIS)

    Post, D.E.; Heifetz, D.; Petravic, M.

    1982-07-01

    Recent progress in models for poloidal divertors has both helped to explain current divertor experiments and contributed significantly to design efforts for future large tokamak (INTOR, etc.) divertor systems. These models range in sophistication from zero-dimensional treatments and dimensional analysis to two-dimensional models for plasma and neutral particle transport which include a wide variety of atomic and molecular processes as well as detailed treatments of the plasma-wall interaction. This paper presents a brief review of some of these models, describing the physics and approximations involved in each model. We discuss the wide variety of physics necessary for a comprehensive description of poloidal divertors. To illustrate the progress in models for poloidal divertors, we discuss some of our recent work as typical examples of the kinds of calculations being done

  14. Models for poloidal divertors

    Energy Technology Data Exchange (ETDEWEB)

    Post, D.E.; Heifetz, D.; Petravic, M.

    1982-07-01

    Recent progress in models for poloidal divertors has both helped to explain current divertor experiments and contributed significantly to design efforts for future large tokamak (INTOR, etc.) divertor systems. These models range in sophistication from zero-dimensional treatments and dimensional analysis to two-dimensional models for plasma and neutral particle transport which include a wide variety of atomic and molecular processes as well as detailed treatments of the plasma-wall interaction. This paper presents a brief review of some of these models, describing the physics and approximations involved in each model. We discuss the wide variety of physics necessary for a comprehensive description of poloidal divertors. To illustrate the progress in models for poloidal divertors, we discuss some of our recent work as typical examples of the kinds of calculations being done.

  15. Energy and particle control characteristics of the ASDEX Upgrade 'LYRA' divertor

    International Nuclear Information System (INIS)

    Kaufmann, M.; Bosch, H.S.; Herrmann, A.

    1999-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and the neutral beam heating power was increased to 20 MW by installation of a second injector. This leads to the relatively high value of P/R of 12 MW/m. It has been shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. Measurements presented in this paper reveal a reduction of the maximum heat flux in the LYRA divertor by more than a factor of two compared to the open Divertor I. This reduction is caused by radiative losses inside the divertor region. Carbon radiation cools the divertor plasma down to a few eV where hydrogen radiation losses become significant. They are increased due to an effective reflection of neutrals into the hot separatrix region. B2-Eirene modelling of the performed experiments supports the experimental findings and refines the understanding of loss processes in the divertor region. (author)

  16. Energy and particle control characteristics of the ASDEX Upgrade 'LYRA' divertor

    International Nuclear Information System (INIS)

    Kaufmann, M.; Bosch, H.-S.; Herrmann, A.

    2001-01-01

    In 1997 the new 'LYRA' divertor went into operation at ASDEX Upgrade and the neutral beam heating power was increased to 20 MW by installation of a second injector. This leads to the relatively high value of P/R of 12 MW/m. It has been shown that the ASDEX Upgrade LYRA divertor is capable of handling such high heating powers. Measurements presented in this paper reveal a reduction of the maximum heat flux in the LYRA divertor by more than a factor of two compared to the open Divertor I. This reduction is caused by radiative losses inside the divertor region. Carbon radiation cools the divertor plasma down to a few eV where hydrogen radiation losses become significant. They are increased due to an effective reflection of neutrals into the hot separatrix region. B2-Eirene modelling of the performed experiments supports the experimental findings and refines the understanding of loss processes in the divertor region. (and others)

  17. Controlling marginally detached divertor plasmas

    Science.gov (United States)

    Eldon, D.; Kolemen, E.; Barton, J. L.; Briesemeister, A. R.; Humphreys, D. A.; Leonard, A. W.; Maingi, R.; Makowski, M. A.; McLean, A. G.; Moser, A. L.; Stangeby, P. C.

    2017-06-01

    A new control system at DIII-D has stabilized the inter-ELM detached divertor plasma state for H-mode in close proximity to the threshold for reattachment, thus demonstrating the ability to maintain detachment with minimal gas puffing. When the same control system was instead ordered to hold the plasma at the threshold (here defined as T e  =  5 eV near the divertor target plate), the resulting T e profiles separated into two groups with one group consistent with marginal detachment, and the other with marginal attachment. The plasma dithers between the attached and detached states when the control system attempts to hold at the threshold. The control system is upgraded from the one described in Kolemen et al (2015 J. Nucl. Mater. 463 1186) and it handles ELMing plasmas by using real time D α measurements to remove during-ELM slices from real time T e measurements derived from divertor Thomson scattering. The difference between measured and requested inter-ELM T e is passed to a PID (proportional-integral-derivative) controller to determine gas puff commands. While some degree of detachment is essential for the health of ITER’s divertor, more deeply detached plasmas have greater radiative losses and, at the extreme, confinement degradation, making it desirable to limit detachment to the minimum level needed to protect the target plate (Kolemen et al 2015 J. Nucl. Mater. 463 1186). However, the observed bifurcation in plasma conditions at the outer strike point with the ion B   ×  \

  18. Divertor plasma physics experiments on the DIII-D tokamak

    International Nuclear Information System (INIS)

    Mahdavi, M.A.; Allen, S.L.; Evans, T.E.

    1996-10-01

    In this paper we present an overview of the results and conclusions of our most recent divertor physics and development work. Using an array of new divertor diagnostics we have measured the plasma parameters over the entire divertor volume and gained new insights into several divertor physics issues. We present direct experimental evidence for momentum loss along the field lines, large heat convection, and copious volume recombination during detachment. These observations are supported by improved UEDGE modeling incorporating impurity radiation. We have demonstrated divertor exhaust enrichment of neon and argon by action of a forced scrape off layer (SOL) flow and demonstrated divertor pumping as a substitute for conventional wall conditioning. We have observed a divertor radiation zone with a parallel extent that is an order of magnitude larger than that estimated from a 1-D conduction limited model of plasma at coronal equilibrium. Using density profile control by divertor pumping and pellet injection we have attained H-mode confinement at densities above the Greenwald limit. Erosion rates of several candidate ITER plasma facing materials are measured and compared with predictions of a numerical model

  19. Nonlinear behavior of the radiative condensation instability

    International Nuclear Information System (INIS)

    McCarthy, D.; Drake, J.F.

    1991-01-01

    An investigation of the nonlinear behavior of the radiative condensation instability is presented in a simple one-dimensional magnetized plasma. It is shown that the radiative condensation is typically a nonlinear instability---the growth of the instability is stronger once the disturbance reaches finite amplitude. Moreover, classical parallel thermal conduction is insufficient by itself to saturate the instability. Radiative collapse continues until the temperature in the high density condensation falls sufficiently to reduce the radiation rate

  20. Textor bundle divertor

    International Nuclear Information System (INIS)

    Yang, T.F.; Wan, A.; Gierszewski, P.; Rapperport, E.; Montgomery, D.B.

    1982-01-01

    This report presents a preliminary bundle divertor conceptual design for installation on the TEXTOR tokamak. An advanced cascade T-shaped coil configuration is used. This divertor design has the following important characteristics: (1) the current density in the conductor is less than 6 kAmp/cm 2 , and the maximum field is less than 6 Tesla; (2) the divertor can be operated at steady-state either for copper or superconducting conductors; (3) the power consumption is about 7 MW for a normal conductor; (4) the divertor can be inserted into the existing geometry of TEXTOR; (5) the ripple on axis is only 0.3% and the mirror ratio is 2 to 4; (6) the stagnation axis is concave toward the plasma, therefore q/sub D/ is smaller, the acceptance angle is larger, and the efficiency may be better than the conventional circular coil design

  1. TEXTOR bundle divertor

    International Nuclear Information System (INIS)

    Yang, T.F.; Wan, A.; Gierszewski, P.; Rapperport, E.; Montgomery, D.B.

    1982-01-01

    This report presents a preliminary bundle divertor conceptual design for installation on the TEXTOR tokamak. An advanced cascade T-shaped coil configuration is used. This divertor design has the following important characteristics: (1) the current density in the conductor is less than 6 kAmp/cm 2 , and the maximum field is less than 6 Tesla; (2) the divertor can be operated at steady-state either for copper or superconducting conductors; (3) the power consumption is about 7 MW for a normal conductor; (4) the divertor can be inserted into the existing geometry of TEXTOR; (5) the ripple on axis is only 0.3% and the mirror ratio is 2 to 4; (6) the stagnation axis is concave toward the plasma, therefore q/sub D/ is smaller, the acceptance angle is larger, and the efficiency may be better than the conventional circular coil design

  2. NSTX Tangential Divertor Camera

    International Nuclear Information System (INIS)

    Roquemore, A.L.; Ted Biewer; Johnson, D.; Zweben, S.J.; Nobuhiro Nishino; Soukhanovskii, V.A.

    2004-01-01

    Strong magnetic field shear around the divertor x-point is numerically predicted to lead to strong spatial asymmetries in turbulence driven particle fluxes. To visualize the turbulence and associated impurity line emission near the lower x-point region, a new tangential observation port has been recently installed on NSTX. A reentrant sapphire window with a moveable in-vessel mirror images the divertor region from the center stack out to R 80 cm and views the x-point for most plasma configurations. A coherent fiber optic bundle transmits the image through a remotely selected filter to a fast camera, for example a 40500 frames/sec Photron CCD camera. A gas puffer located in the lower inboard divertor will localize the turbulence in the region near the x-point. Edge fluid and turbulent codes UEDGE and BOUT will be used to interpret impurity and deuterium emission fluctuation measurements in the divertor

  3. 'EU divertor celebration day'

    International Nuclear Information System (INIS)

    Merola, M.

    2002-01-01

    The meeting 'EU divertor celebration day' organized on 16 January 2002 at Plansee AG, Reutte, Austria was held on the occasion of the completion of manufacturing activities of a complete set of near full-scale prototypes of divertor components including the vertical target, the dome liner and the cassette body. About 30 participants attended the meeting including Dr. Robert Aymar, ITER Director, representatives from EFDA, CEA, ENEA, IPP and others

  4. T-12 divertor experiment

    Energy Technology Data Exchange (ETDEWEB)

    Bortnikov, A V; Brevnov, N N; Gerasimov, S N; Zhukovskii, V G; Kuznetsov, N V; Naftulin, S M; Pergament, V I; Khimchenko, L N [Gosudarstvennyj Komitet po Ispol' zovaniyu Atomnoj Ehnergii SSSR, Moscow. Inst. Atomnoj Ehnergii

    1981-01-01

    In designing tokamak devices and reactors, in the last few years, the use of elongated-cross-section plasma discharges has been proposed to improve the economic and physical parameters. Application of a quadrupole poloidal magnetic field necessary for sustaining the elongated discharge cross-section serves, in this case, to create the magnetic configuration of an axisymmetric poloidal divertor. To-day, the creation of such a combination, including an elongated plasma cross-section and a divertor and using the outer poloidal magnetic field coils, seems to be the most reasonable approach, from the point of view of design and technology. Such a divertor was produced and studied at the T-12 tokamak. A stable equilibrium configuration of a finger-ring tokamak with a divertor has been produced by superposing the magnetic fields of the plasma current, the external quadrupole coils and the copper shell currents; the reactor blanket can fulfil the function of the latter. It is shown that both a symmetric magnetic configuration with two divertors and a droplet configuration with a single divertor may be realized by controlling the plasma column position with respect to the equatorial plane. The stability of the plasma column against vertical displacement depends on this position and the distance between the separatrix points. Vertical instability stabilization has been observed. The divertor layer efficiently screens the plasma from the impurity influx from the wall and unloads the wall from particle and energy fluxes. The results obtained from the tokamak T-12 experiment have demonstrated the capability of a system with outer poloidal field coils and a copper shell providing an elongated-cross-section plasma column with poloidal divertors.

  5. Divertor design for the TITAN reversed-field-pinch reactor

    International Nuclear Information System (INIS)

    Cooke, P.I.H.; Bathke, C.G.; Blanchard, J.P.; Creedon, R.L.; Grotz, S.P.; Hasan, M.Z.; Orient, G.; Sharafat, S.; Werley, K.A.

    1987-01-01

    The design of the toroidal-field divertor for the TITAN high-power-density reversed-field-pinch reactor is described. The heat flux on the divertor target is limited to acceptable levels (≤ 10 MW/m 2 ) for liquid-lithium cooling by use of an open divertor geometry, strong radiation from the core and edge plasma, and careful shaping of the target surface. The divertor coils are based on the Integrated-Blanket-Coil approach to minimize the loss in breeding-blanket coverage due to the divertor. A tungsten-rhenium armour plate, chosen for reasons of sputtering resistance, and good thermal and mechanical properties, protects the vanadium-alloy coolant tubes

  6. Divertor heat flux control and plasma-material interaction

    International Nuclear Information System (INIS)

    Kikuchi, Yusuke; Nagata, Masayoshi; Sawada, Keiji; Takamura, Shuichi; Ueda, Yoshio

    2014-01-01

    Development of reliable radiative-cooling divertors is essential in DEMO reactor because it uses low-activation materials with low heat removal and the plasma heat flux exhausted from the confined region is 5 times as large as in ITER. It is important to predict precisely the heat and particle flux toward the divertor plate by simulation. In this present article, theoretical and experimental data of the reflection, secondary emission and surface recombination coefficients of the divertor plate by ion bombardment are given and their effects on the power transmission coefficient are discussed. In addition, some topics such as the erosion process of the divertor plate by ELM and the plasma disruption, the thermal shielding due to the vapor layer on the divertor plate and the formation of fuzz structure on W by helium plasma irradiation, are described. (author)

  7. Physical study of experimental fusion breeder FEB divertor

    International Nuclear Information System (INIS)

    Zhu Yukun; Zhou Xiaobing; Huang Jinhua; Feng Kaiming; Deng Peizhi; Huo Tiejun

    1999-10-01

    The physical study of FEB divertor is presented. In order to improve the impurity control and increase ion-neutral interactions in the divertor, the configuration of the divertor is optimized to be the close type in the engineering design activity compared with the open type in the early conceptual activity. The operation mode of the divertor is designed to be partial detached plasma mode under conditions of combination gas-puffing with impurity injection. The position of gas-puffing is optimized to be at the torus mid-plane with NEWT1D code from the viewpoint of impurity retention and radiation in the scrape-off layer/divertor region. Boron is chosen as the injected impurity. The effect of boron impurity injection is evaluated from the reduced heat load on the divertor target. The plasma pressure drop along the scrape-off layer/divertor region is estimated with the two-point transport model and impurity radiation model in the dynamic gas target concept. The simulation results show that the plasma pressure drop factor f p is not only related to the radiation fraction f rad but also related greatly to the stagnation point density n s

  8. Engineering design of the Aries-IV gaseous divertor

    International Nuclear Information System (INIS)

    Hasan, M.Z.; Najmabadi, F.; Sharafat, S.

    1994-01-01

    ARIES-IV is a conceptual, D-T burning, steady-state tokamak fusion reactor producing 1000 MWe net. It operates in the second plasma stability regime. The structural material is SiC composite and the primary coolant is helium at 10MPa base pressure. ARIES-IV uses double-null divertors for particle control. Total thermal power recovered from the divertors is 425MW, which is 16% of the total reactor thermal power. Among the desirable goals of divertor design were to avoid the use of tungsten and to use the same structural material and primary coolant as in the blanket design. In order to reduce peak heat flux, the innovative gaseous divertor has been used in ARIES-IV. A gaseous divertor reduces peak heat flux by increasing the surface area and by distributing particle and radiation energy more uniformly. Another benefit of gaseous divertor is the reduction of plasma temperature in the divertor chamber, so that material erosion due to sputtering, can be diminished. This makes the use of low-Z material possible in a gaseous divertor

  9. Divertor tungsten tiles erosion in the region of the castellated gaps

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Wanpeng, E-mail: wangdez@dlut.edu.cn; Sang, Chaofeng; Sun, Zhenyue; Wang, Dezhen

    2016-11-01

    Highlights: • Simulation of the tungsten tiles erosion by different impurities in the divertor gap region is done by using a 2d3v Particle-In-Cell code. • High-Z impurity causes the largest erosion rate on W tile. • The peak physical sputtering erosion rate locates at the plasma-facing corners. - Abstract: Erosion of tungsten (W) is a very important issue for the future fusion device. The castellated divertor makes it more complicated due to complex geometry of the gap between the tiles. In this work, the plasma behaviors and resulting W tile erosion in the divertor tile gap region are studied by using a two dimension-in-space and three dimension-in-velocity (2d3 v) Particle-In-Cell (PIC) code. Deuterium ions (D{sup +}) and electrons are traced self-consistently in the simulation to provide the plasma background. Since there are lots of impurities, which may make a great impact on the tile erosion, in the divertor region to radiate the power, the erosion of W tile by different species are thus considered. The contributions of deuterium and impurities: Li, C, Ne, and Ar, to the W erosion, are studied under EAST conditions to show a straightforward insight. It is observed that the physical sputtering of W tile by impurities is much higher than that by the D ions, and the peak erosion region locates at the plasma-facing corners.

  10. Compatibility of detached divertor operation with robust edge pedestal performance

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, A.W., E-mail: leonard@fusion.gat.com [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Makowski, M.A.; McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Osborne, T.H.; Snyder, P.B. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States)

    2015-08-15

    The compatibility of detached radiative divertor operation with a robust H-mode pedestal is examined in DIII-D. A density scan produced low temperature plasmas at the divertor target, T{sub e} ⩽ 2 eV, with high radiation leading to a factor of ⩾4 drop in peak divertor heat flux. The cold radiative plasma was confined to the divertor and did not extend across the separatrix in X-point region. A robust H-mode pedestal was maintained with a small degradation in pedestal pressure at the highest densities. The response of the pedestal pressure to increasing density is reproduced by the EPED pedestal model. However, agreement of the EPED model with experiment at high density requires an assumption of reduced diamagnetic stabilization of edge Peeling–Ballooning modes.

  11. Versator divertor experiment: preliminary designs

    International Nuclear Information System (INIS)

    Wan, A.S.; Yang, T.F.

    1984-08-01

    The emergence of magnetic divertors as an impurity control and ash removal mechanism for future tokamak reactors bring on the need for further experimental verification of the divertor merits and their ability to operate at reactor relevant conditions, such as with auxiliary heating. This paper presents preliminary designs of a bundle and a poloidal divertor for Versator II, which can operate in conjunction with the existing 150 kW of LHRF heating or LH current drive. The bundle divertor option also features a new divertor configuration which should improve the engineering and physics results of the DITE experiment. Further design optimization in both physics and engineering designs are currently under way

  12. Experimental studies on an axisymmetric divertor in DIVA(JFT-2a)

    International Nuclear Information System (INIS)

    Yamamoto, Shin

    1979-03-01

    DIVA(JFT-2a) is the first tokamak with an axisymmetric divertor in the world. Objectives of the experiments were i) Plasma production and confinement in a tokamak with a separatrix magnetic surface, and ii) divertor effects on radiation loss and plasma confinement. The results so far are as follows: i) The equilibrium with a separatrix magnetic surface is stable during the discharge. ii) There is an ergodic region near the separatrix magnetic surface due to non-axisymmetric magnetic perturbations. iii) The divertor reduces radiation loss and increases energy confinement time. iv) The divertor does not affect the transport process in the main plasma. (author)

  13. Snowflake Divertor Configuration in NSTX

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.; Ahn, Joonwook; Bell, R.E.; Gates, D.A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H.W.; LeBlanc, B.; Maingi, Rajesh; Maqueda, R.J.; McLean, Adam G.; Menard, J.E.; Mueller, D.; Paul, S.F.; Raman, R.; Roquemore, L.; Ryutov, D.D.; Scott, H.A.

    2011-01-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel 'snowflake' divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  14. 'Snowflake' divertor configuration in NSTX

    International Nuclear Information System (INIS)

    Soukhanovskii, V.A.; Ahn, J.-W.; Bell, R.E.; Gates, D.A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H.W.; LeBlanc, B.P.; Maingi, R.; Maqueda, R.; McLean, A.; Menard, J.E.; Mueller, D.M.; Paul, S.F.; Raman, R.; Roquemore, A.L.; Ryutov, D.D.; Scott, H.A.

    2011-01-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel 'snowflake' divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  15. "Snowflake" divertor configuration in NSTX

    Science.gov (United States)

    Soukhanovskii, V. A.; Ahn, J.-W.; Bell, R. E.; Gates, D. A.; Gerhardt, S.; Kaita, R.; Kolemen, E.; Kugel, H. W.; Leblanc, B. P.; Maingi, R.; Maqueda, R.; McLean, A.; Menard, J. E.; Mueller, D. M.; Paul, S. F.; Raman, R.; Roquemore, A. L.; Ryutov, D. D.; Scott, H. A.

    2011-08-01

    Steady-state handling of divertor heat flux is a critical issue for present and future conventional and spherical tokamaks with compact high power density divertors. A novel "snowflake" divertor (SFD) configuration that takes advantage of magnetic properties of a second-order poloidal null has been predicted to have a larger plasma-wetted area and a larger divertor volume, in comparison with a standard first-order poloidal X-point divertor configuration. The SFD was obtained in 0.8 MA, 4-6 MW NBI-heated H-mode discharges in NSTX using two divertor magnetic coils. The SFD led to a partial detachment of the outer strike point even in low-collisionality scrape-off layer plasma obtained with lithium coatings in NSTX. Significant divertor peak heat flux reduction and impurity screening have been achieved simultaneously with good core confinement and MHD properties.

  16. The effect of charge exchange with neutral deuterium on carbon emission in JET divertor plasmas

    International Nuclear Information System (INIS)

    Maggi, C.; Horton, L.; Summers, H.

    1999-11-01

    High density, low temperature divertor plasma operation in tokamaks results in large neutral deuterium concentrations in the divertor volume. In these conditions, low energy charge transfer reactions between neutral deuterium and the impurity ions can in principle enhance the impurity radiative losses and thus help to reduce the maximum heat load to the divertor target. A quantitative study of the effect of charge exchange on carbon emission is presented, applied to the JET divertor. Total and state selective effective charge exchange recombination rate coefficients were calculated in the collisional radiative picture. These coefficients were coupled to divertor and impurity transport models to study the effect of charge exchange on the measured carbon spectral emission in JET divertor discharges. The sensitivity of the effect of charge exchange to the assumptions in the impurity transport model was also investigated. A reassessment was made of fundamental charge exchange cross section data in support of this study. (author)

  17. Effect of low density H-mode operation on edge and divertor plasma parameters

    International Nuclear Information System (INIS)

    Maingi, R.; Mioduszewski, P.K.; Cuthbertson, J.W.

    1994-07-01

    We present a study of the impact of H-mode operation at low density on divertor plasma parameters on the DIII-D tokamak. The line-average density in H-mode was scanned by variation of the particle exhaust rate, using the recently installed divertor cryo-condensation pump. The maximum decrease (50%) in line-average electron density was accompanied by a factor of 2 increase in the edge electron temperature, and 10% and 20% reductions in the measured core and divertor radiated power, respectively. The measured total power to the inboard divertor target increased by a factor of 3, with the major contribution coming from a factor of 5 increase in the peak heat flux very close to the inner strike point. The measured increase in power at the inboard divertor target was approximately equal to the measured decrease in core and divertor radiation

  18. Divertor design for the Tokamak Physics Experiment

    International Nuclear Information System (INIS)

    Hill, D.N.; Braams, B.

    1994-05-01

    In this paper we discuss the present divertor design for the planned TPX tokamak, which will explore the physics and technology of steady-state (1000s pulses) heat and particle removal in high confinement (2--4x L-mode), high beta (β N ≥ 3) divertor plasmas sustained by non-inductive current drive. The TPX device will operate in the double-null divertor configuration, with actively cooled graphite targets forming a deep (0.5 m) slot at the outer strike point. The peak heat flux on, the highly tilted (74 degrees from normal) re-entrant (to recycle ions back toward the separatrix) will be in the range of 4--6 MW/m 2 with 18 MW of neutral beams and RF heating power. The combination of active pumping and gas puffing (deuterium plus impurities), along with higher heating power (45 MW maximum) will allow testing of radiative divertor concepts at ITER-like power densities

  19. The MAST improved divertor

    International Nuclear Information System (INIS)

    Darke, A.C.; Hayward, R.J.; Counsell, G.F.; Hawkins, K.

    2005-01-01

    The Mega Amp Spherical Tokamak (MAST) at Culham is one of the leading world machines studying the spherical tokamak (ST) concept. At the time of the initial construction in 1998 little was known about the sort of divertor structures that would be required in an ST. The machine was therefore provided with relatively rudimentary structures that were designed mostly to protect important components from the hot plasma. While these have served the machine well it was accepted that they might not be suitable when operating MAST to its full potential. The years of experience of operating MAST have led to the design, manufacture and now installation of a new divertor, the MAST improved divertor (MID), that should be able to cope with the full performance of the machine. The design is based on imbricated (fan-shaped) disks of tiles at the top and bottom of the machine for the outer strike points, giving an excellent compromise between power handling and diagnostic access, with substantial new centre column strike point armour and a shaped plate in between. High purity graphite is chosen as the plasma facing material in preference to CFC since in this case it has a better balance of performance and cost. The lower imbricated disk is insulated in alternate sectors for studies of divertor biasing and extensive diagnostics and additional inboard gas injection are included

  20. Comparison of 2D simulations of detached divertor plasmas with divertor Thomson measurements in the DIII-D tokamak

    Directory of Open Access Journals (Sweden)

    T.D. Rognlien

    2017-08-01

    Full Text Available A modeling study is reported using new 2D data from DIII-D tokamak divertor plasmas and improved 2D transport model that includes large cross-field drifts for the numerically difficult low anomalous transport regime associated with the H-mode. The data set, which spans a range of plasma densities for both forward and reverse toroidal magnetic field (Bt, is provided by divertor Thomson scattering (DTS. Measurements utilizing X-point sweeping give corresponding 2D profiles of electron temperature (Te and density (ne across both divertor legs for individual discharges. The simulations focus on the open magnetic field-line regions, though they also include a small region of closed field lines. The calculations show the same features of in/out divertor plasma asymmetries as measured in the experiment, with the normal Bt direction (ion ∇B drift toward the X-point having higher ne and lower Te in the inner divertor leg than outer. Corresponding emission data for total radiated power shows a strong inner-divertor/outer-divertor asymmetry that is reproduced by the simulations. These 2D UEDGE transport simulations are enabled for steep-gradient H-mode conditions by newly implemented algorithms to control isolated grid-scale irregularities.

  1. Dynamic behavior of detached recombining plasmas during ELM-like plasma heat pulses in the divertor plasma simulator NAGDIS-II

    International Nuclear Information System (INIS)

    Uesugi, Y.; Hattori, N.; Nishijima, D.; Ohno, N.; Takamura, S.

    2001-01-01

    It has been recognized that the ELMs associated with a good confinement at the edge, such as H-mode, must bring an enormous energy to the divertor target plate through SOL and detached plasmas. The understanding of the ELM energy transport through SOL to the divertor target is rather poor at the moment, which leads to an ambiguous estimation of the deposited heat load on the divertor target in ITER. In the present work the ELM-like plasma heat pulse is generated by rf heating in a linear divertor plasma simulator. Energetic electrons with an energy range 10-40 eV are effectively generated by rf heating in low temperature plasmas with (T e )< ∼1 eV. It is observed experimentally that the energetic electrons ionize the highly excited Rydberg atoms quickly, bringing a rapid increase of the ion particle flux to the target, and make the detached plasmas attached to the target. Detailed physical processes about the interaction between the heat pulse with conduction and convection, and detached recombining plasmas are discussed

  2. The JET divertor coil

    International Nuclear Information System (INIS)

    Last, J.R.; Froger, C.; Sborchia, C.

    1989-01-01

    The divertor coil is mounted inside the Jet vacuum vessel and is able to carry 1 MA turns. It is of conventional construction - water cooled copper, epoxy glass insulation -and is contained in a thin stainless steel case. The coil has to be assembled, insulated and encased inside the Jet vacuum vessel. A description of the coil is given, together with technical information (including mechanical effects on the vacuum vessel), an outline of the manufacture process and a time schedule. (author)

  3. CIT divertor conceptual design

    International Nuclear Information System (INIS)

    Wesley, J.C.; Sevier, D.L.

    1988-06-01

    A conceptual design of the divertor target assembly for the 1.75-m CIT baseline device has been developed. The divertor target assembly consists of four toroidal arrays of pyrolytic graphite plates that cover the inside surface of the ends of the vacuum vessel in the locations where the magnetic separatrices of the plasma intersect the vessel wall. During the course of the plasma discharge, the currents on the poloidal field coils that establish the plasma equilibrium are varied to sweep the separatrix strike locations across the divertor targets. This spreads the plasma heat loading over sufficient area to keep the peak target surface temperature within allowable limits. The required magnetic sweep (/+-/5 cm for the inside strike location and /+-/12 cm for the outside strike location) can be affected by programming either the external poloidal strike location) can be effected by programming either the external poloidal field (PF) coils or the internal PF control coils plus the external PF solenoid coils (PF1 and PF2). The ensuing variations in the elongation and triangularity of the plasma are modest, and fall within the ranges of plasma elongation and triangularity specified in the CIT General Requirements Document. 17 figs., 13 tabs

  4. NSTX Plasma Response to Lithium Coated Divertor

    Energy Technology Data Exchange (ETDEWEB)

    H.W. Kugel, M.G. Bell, J.P. Allain, R.E. Bell, S. Ding, S.P. Gerhardt, M.A. Jaworski, R. Kaita, J. Kallman, S.M. Kaye, B.P. LeBlanc, R. Maingi, R. Majeski, R. Maqueda, D.K. Mansfield, D. Mueller, R. Nygren, S.F. Paul, R. Raman, A.L. Roquemore, S.A. Sabbagh, H. Schneider, C.H. Skinner, V.A. Soukhanovskii, C.N. Taylor, J.R. Timberlak, W.R. Wampler, L.E. Zakharov, S.J. Zweben, and the NSTX Research Team

    2011-01-21

    NSTX experiments have explored lithium evaporated on a graphite divertor and other plasma facing components in both L- and H- mode confinement regimes heated by high-power neutral beams. Improvements in plasma performance have followed these lithium depositions, including a reduction and eventual elimination of the HeGDC time between discharges, reduced edge neutral density, reduced plasma density, particularly in the edge and the SOL, increased pedestal electron and ion temperature, improved energy confinement and the suppression of ELMs in the H-mode. However, with improvements in confinement and suppression of ELMs, there was a significant secular increase in the effective ion charge Zeff and the radiated power in H-mode plasmas as a result of increases in the carbon and medium-Z metallic impurities. Lithium itself remained at a very low level in the plasma core, <0.1%. Initial results are reported from operation with a Liquid Lithium Divertor (LLD) recently installed.

  5. NSTX plasma response to lithium coated divertor

    International Nuclear Information System (INIS)

    Kugel, H.W.; Bell, M.G.; Allain, J.P.; Bell, R.E.; Ding, S.; Gerhardt, S.P.; Jaworski, M.A.; Kaita, R.; Kallman, J.; Kaye, S.M.; LeBlanc, B.P.; Maingi, Rajesh; Majeski, R.; Maqueda, R.J.; Mansfield, D.K.; Mueller, D.; Nygren, R.E.; Paul, S.F.; Raman, R.; Roquemore, A.L.; Sabbagh, S.A.; Schneider, H.; Skinner, C.H.; Soukhanovskii, V.A.; Taylor, C.N.; Timberlake, J.; Wampler, W.R.; Zakharov, L.E.; Zweben, S.J.

    2011-01-01

    NSTX experiments have explored lithium evaporated on a graphite divertor and other plasma-facing components in both L- and H- mode confinement regimes heated by high-power neutral beams. Improvements in plasma performance have followed these lithium depositions, including a reduction and eventual elimination of the HeGDC time between discharges, reduced edge neutral density, reduced plasma density, particularly in the edge and the SOL, increased pedestal electron and ion temperature, improved energy confinement and the suppression of ELMs in the H-mode. However, with improvements in confinement and suppression of ELMs, there was a significant secular increase in the effective ion charge Z(eff) and the radiated power in H-mode plasmas as a result of increases in the carbon and medium-Z metallic impurities. Lithium itself remained at a very low level in the plasma core, < 0.1%. Initial results are reported from operation with a Liquid Lithium Divertor (LLD) recently installed.

  6. Turbulent Simulations of Divertor Detachment Based On BOUT + + Framework

    Science.gov (United States)

    Chen, Bin; Xu, Xueqiao; Xia, Tianyang; Ye, Minyou

    2015-11-01

    China Fusion Engineering Testing Reactor is under conceptual design, acting as a bridge between ITER and DEMO. The detached divertor operation offers great promise for a reduction of heat flux onto divertor target plates for acceptable erosion. Therefore, a density scan is performed via an increase of D2 gas puffing rates in the range of 0 . 0 ~ 5 . 0 ×1023s-1 by using the B2-Eirene/SOLPS 5.0 code package to study the heat flux control and impurity screening property. As the density increases, it shows a gradually change of the divertor operation status, from low-recycling regime to high-recycling regime and finally to detachment. Significant radiation loss inside the confined plasma in the divertor region during detachment leads to strong parallel density and temperature gradients. Based on the SOLPS simulations, BOUT + + simulations will be presented to investigate the stability and turbulent transport under divertor plasma detachment, particularly the strong parallel gradient driven instabilities and enhanced plasma turbulence to spread heat flux over larger surface areas. The correlation between outer mid-plane and divertor turbulence and the related transport will be analyzed. Prepared by LLNL under Contract DE-AC52-07NA27344. LLNL-ABS-675075.

  7. Numerical studies on divertor experiments

    International Nuclear Information System (INIS)

    Ueda, N.; Itoh, K.; Itoh, S.-I.; Tanaka, M.; Hasegawa, M.; Shoji, T.; Sugihara, M.

    1988-04-01

    Numerical analysis on the divertor experiments such as JFT-2M tokamak is made by use of the two-dimensional time-dependent simulation code. The plasma in the scrape-off layer (SOL) and divertor region is solved for the given particle and heat sources from the main plasma, Γ p and Q T . Effect of the direction of the toroidal magnetic field is studied. It is found that the heat flux which is proportional to b vector x ∇T i has influences on the divertor plasmas, but has a small effect on the parameters on the midplane in the framework of the fluid model. Parameter survey on Γ p and Q T is made. The transient response of the SOL/divertor plasma to the sudden change of Γ p and Q T is studied. Time delay in the SOL and divertor region is calculated. (author)

  8. One dimensional simulation on stability of detached plasma in a tokamak divertor

    International Nuclear Information System (INIS)

    Nakazawa, Shinji; Nakajima, Noriyoshi; Okamoto, Masao; Ohyabu, Nobuyoshi

    1999-06-01

    The stability of radiation front in the Scrape-Off-Layer (SOL) of a tokamak is studied with a one dimensional fluid code; the time-dependent transport equations are solved in the direction parallel to a magnetic field line. The simulation results show that stable detached solutions exist, where the plasma temperature near the divertor target is ∼2 eV. It is found that whenever such stable detached states are attained, the strong radiation front is contact with or at a small distance from the divertor target. When the energy externally injected into the SOL is decreased below a critical value, the radiation front starts to move towards the X-point, cooling the SOL plasma. In such cases, no stationary solutions such that the radiation front rests in the divertor channel are observed in our parameter space. This qualitatively corresponds to the results of tokamak divertor experiments which show the movement of radiation front. (author)

  9. Divertor experiment for impurity control in DIVA

    International Nuclear Information System (INIS)

    Nagami, Masayuki

    1979-04-01

    Divertor actions of controlling the impurities and the transport of impurity ions in the plasma have been investigated in the DIVA device. Following are the results: (1) The radial transport of impurity ions is not described only by neoclassical theory, but it is strongly influenced by anomalous process. Radial diffusion of impurity ions across the whole minor radius is well described by a neoclassical diffusion superposed by the anomalous diffusion for protons. Due to this anomalous process, which spreads the radial density profile of impurity ions, 80 to 90% of the impurity flux in the plasma outer edge is shielded even in a nondiverted discharge. (2) The divertor reduces the impurity flux entering the main plasma by a factor of 2 to 4. The impurity ions shielded by the scrape-off plasma are rapidly guided into the burial chamber with a poloidal excursion time roughly equal to that of the scrape-off plasma. (3) The divertor reduces the impurity ion flux onto the main vacuum chamber by guiding the impurity ions diffusing from the main plasma into the burial chamber, thereby reducing the plasma-wall interaction caused by diffusing impurity ions at the main vacuum chamber. The impurity ions produced in the burial chamber may flow back to the main plasma through the scrape-off layer. However, roughly only 0.3% of the impurity flux into the scrape-off plasma in the burial chamber penetrates into the main plasma due to the impurity backflow. (4) A slight cooling of the scrape-off plasma with light-impurity injection effectively reduces the metal impurity production at the first wall by reducing the potential difference between the plasma and the wall, thereby reducing the accumulation of the metal impurity in the discharge. Radiation cooling by low-Z impurities in the plasma outer edge, which may become an important feature in future large tokamaks both with and without divertor, is numerically evaluated for carbon, oxygen and neon. (author)

  10. EMC3-EIRENE modeling of toroidally-localized divertor gas injection experiments on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Lore, J.D., E-mail: lorejd@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Reinke, M.L. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); LaBombard, B. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Lipschultz, B. [York Plasma Institute, Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom); Churchill, R.M. [Plasma Science and Fusion Center, MIT, Cambridge, MA 02139 (United States); Pitts, R.A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Feng, Y. [Max Planck Institute for Plasma Physics, Greifswald (Germany)

    2015-08-15

    Experiments on Alcator C-Mod with toroidally and poloidally localized divertor nitrogen injection have been modeled using the three-dimensional edge transport code EMC3-EIRENE to elucidate the mechanisms driving measured toroidal asymmetries. In these experiments five toroidally distributed gas injectors in the private flux region were sequentially activated in separate discharges resulting in clear evidence of toroidal asymmetries in radiated power and nitrogen line emission as well as a ∼50% toroidal modulation in electron pressure at the divertor target. The pressure modulation is qualitatively reproduced by the modeling, with the simulation yielding a toroidal asymmetry in the heat flow to the outer strike point. Toroidal variation in impurity line emission is qualitatively matched in the scrape-off layer above the strike point, however kinetic corrections and cross-field drifts are likely required to quantitatively reproduce impurity behavior in the private flux region and electron temperatures and densities directly in front of the target.

  11. High temperature divertor plasma operation

    International Nuclear Information System (INIS)

    Ohyabu, Nobuyoshi.

    1991-02-01

    High temperature divertor plasma operation has been proposed, which is expected to enhance the core energy confinement and eliminates the heat removal problem. In this approach, the heat flux is guided through divertor channel to a remote area with a large target surface, resulting in low heat load on the target plate. This allows pumping of the particles escaping from the core and hence maintaining of the high divertor temperature, which is comparable to the core temperature. The energy confinement is then determined by the diffusion coefficient of the core plasma, which has been observed to be much lower than the thermal diffusivity. (author)

  12. Divertor scaling laws for tokamaks

    International Nuclear Information System (INIS)

    Catto, P.J.; Krasheninnikov, S.I.; Connor, J.W.

    1997-01-01

    The breakdown of two body scaling laws is illustrated by using the two dimensional plasma code UEDGE coupled to an advanced Navier-Stokes neutrals transport package to model attached and detached regimes in a simplified geometry. Two body similarity scalings are used as benchmarks for runs retaining non-two body modifications due to the effects of (i) multi-step processes altering ionization and radiation via the excited states of atomic hydrogen and (ii) three body recombination. Preliminary investigations indicate that two body scaling interpretations of experimental data fail due to (i) multi-step processes when a significant region of the plasma exceeds a plasma density of 10 19 m -3 , or (ii) three body recombination when there is a significant region in which the temperature is ≤1 eV while the plasma density is ≥10 20 m -3 . These studies demonstrate that two body scaling arguments are often inappropriate in the divertor and the first results for alternate scalings are presented. (orig.)

  13. Divertor development for ITER

    International Nuclear Information System (INIS)

    Janeschitz, G.; Ando, T.; Antipenkov, A.; Barabash, V.; Chiocchio, S.; Federici, G.; Ibbott, C.; Jakeman, R.; Matera, R.; Martin, E.; Parker, R.; Tivey, R.; Pacher, H.D.

    1998-01-01

    The requirements for the ITER divertor design, i.e. power and He ash exhaust, neutral leakage control, lifetime, disruption load resistance and exchange by remote handling, are described in this paper. These requirements and the physics requirements for detached and semi-attached operation result in the vertical target configuration. This is realised by a concept incorporating 60 cassettes carrying the high heat flux components. The armour choice for these components is CFC monoblock in the strike zone near at the lower part of the vertical target, and a W brush elsewhere. Cooling is by swirl tubes or hypervapotrons depending on the component. The status of the heat sink and joining technology R and D is given. Finally, the resulting design of the high heat flux components is presented. (orig.)

  14. The divertor remote maintenance project

    International Nuclear Information System (INIS)

    Maisonnier, D.; Martin, E.; Akou, K.

    2001-01-01

    Remote replacement of the ITER divertor will be required several times during the life of ITER. To facilitate its regular exchange, the divertor is assembled in the ITER vacuum vessel from 60 cassettes. Radial movers transport each cassette along radial rails through the handling ports and into the vessel where a toroidal mover lifts and transports the cassette around a pair of toroidal rails. Once at its final position the cassette is locked to the toroidal rails and is accurately aligned in both poloidal and toroidal directions. A further requirement on the divertor is to minimise the amount of activated waste to be sent to a repository. To this end the cassettes have been designed to allow the remote replacement, in a hot cell, of their plasma facing components. The paper describes the two facilities built at ENEA Brasimone, Italy, whose aim is to demonstrate the reliable remote maintenance of the divertor cassettes. (author)

  15. The divertor remote maintenance project

    International Nuclear Information System (INIS)

    Maisonnier, D.; Martin, E.; Akou, K.

    1999-01-01

    Remote replacement of the ITER divertor will be required several times during the life of ITER. To facilitate its regular exchange, the divertor is assembled in the ITER vacuum vessel from 60 cassettes. Radial movers transport each cassette along radial rails through the handling ports and into the vessel where a toroidal mover lifts and transports the cassette around a pair of toroidal rails. Once at its final position the cassette is locked to the toroidal rails and is accurately aligned in both poloidal and toroidal directions. A further requirement on the divertor is to minimise the amount of activated waste to be sent to a repository. To this end the cassettes have been designed to allow the remote replacement, in a hot cell, of their plasma facing components. The paper describes the two facilities built at ENEA Brasimone, Italy, whose aim is to demonstrate the reliable remote maintenance of the divertor cassettes. (author)

  16. Proposal of an alternative upper divertor in ASDEX Upgrade supported by EMC3-EIRENE simulations

    Directory of Open Access Journals (Sweden)

    T. Lunt

    2017-08-01

    Full Text Available We discuss the benefits of installing a pair of in-vessel coils with currents |Ifx| ≲ 50 kAt in the upper divertor of ASDEX Upgrade (AUG to study a series of ‘alternative’ divertor configurations, like the Snowflake (SF and the X-divertor (XD, that are currently considered as alternative solutions for the power exhaust problem. The possibility of operating the standard lower single-null (SN and double-null (DN would be preserved. Potential effects to reduce the peak parallel- and/or perpendicular heat flux are predicted from a simple geometrical-diffusive model as well as by numerical EMC3-EIRENE simulations for pure deuterium attached conditions with spatially constant diffusion coefficients. Beyond that a series of other potential transport- and radiation related heat flux mitigation effects are identified and could be studied experimentally with the modified upper divertor in the high-power divertor Tokamak AUG.

  17. Effects of divertor geometry and pumping on plasma performance on DIII-D

    International Nuclear Information System (INIS)

    Allen, S.L.; Hill, D.N.; Porter, G.D.

    1997-06-01

    This paper reports the status of an ongoing investigation to discern the influence of the divertor and plasma geometry on the confinement of both ELM-free and ELMing discharges in DIII-D. The ultimate goal is to achieve a high-performance core plasma which coexists with an advanced divertor plasma. The divertor plasma must reduce the heat flux to acceptable levels; the current technique disperses the heat flux over a wide area by radiation (a radiative divertor). To date, we have obtained our best performance in double-null (DN) high-triangularity (δ ∼ 0.8) ELM-free discharges. As discussed in detail elsewhere, there are several advantages for both the core and divertor plasma with highly-shaped DN operation. Previous radiative-divertor experiments with D 2 injection in DN high-δ ELMing H-mode have shown that this configuration is more sensitive to gas puffing (τ decreases). Moving the X-point away from the target plate (to ∼15 cm above the plate) decreases this sensitivity. Preliminary measurements also indicate that gas puffing reduces the divertor heat flux but does not reduce the plasma pressure along the field line. The up/down heat flux balance can be varied magnetically (by changing the distance between the separatrices), with a slight magnetic imbalance required to balance the heat flux. The overall mission of the Radiative Divertor Project (RDP) is to install a fully pumped and baffled high-δ DN divertor. To date, however, both the DIII-D divertor diagnostics and pump were optimized for lower single-null (LSN) low-δ (δ∼ 0.4) plasmas, so much of the divertor physics has been performed in LSN; these results are discussed in Section 2. As part of the first phase of the RDP, we have installed a new high-δ USN divertor baffle and pump; these results are discussed in Section 3. Both divertor and core parameters are discussed in each case

  18. Hydrogen recycling and transport in the helical divertor of TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    Clever, Meike

    2010-07-01

    observed. Its absence can be explained using an extended two point model including heat convection applied to the region dominated by parallel transport (laminar region). The radial penetration depth of the neutral hydrogen particles ({lambda}{sub n} {approx} 3-4 cm) estimated from spectroscopic measurements was found to be often larger than the varying radial extent of this laminar region (few mm up to 6 cm) which finally leads to convective heat transport reducing parallel temperature gradients. Increasing the radial extent of the laminar region especially in front of the divertor strike points could lead to an improvement in this respect and provide access to a high recycling regime. The radiation instability developing at high plasma densities in the helical divertor in TEXTOR is preceded by a transient partial detachment of the plasma from the divertor target plates and leads to the formation of a poloidally structured and helically inclined radiating belt, a helical divertor MARFE. While typically leading to a density limit disruption, this MARFE has been stabilised using a feedback system and could provide some divertor functionality such as low target temperature, increased neutral density and increased radiation within the stochastic boundary. Simulations using two different cross-field transport coefficients showed, that an agreement is only found at a certain level of cross-field transport (D {sub perpendicular} {sub to} =1 m{sup 2}s{sup -1}). The inclusion of carbon impurities in the simulations results in the experimentally observed reduction of the recycling flux. (orig.)

  19. Hydrogen recycling and transport in the helical divertor of TEXTOR

    International Nuclear Information System (INIS)

    Clever, Meike

    2010-01-01

    observed. Its absence can be explained using an extended two point model including heat convection applied to the region dominated by parallel transport (laminar region). The radial penetration depth of the neutral hydrogen particles (λ n ∼ 3-4 cm) estimated from spectroscopic measurements was found to be often larger than the varying radial extent of this laminar region (few mm up to 6 cm) which finally leads to convective heat transport reducing parallel temperature gradients. Increasing the radial extent of the laminar region especially in front of the divertor strike points could lead to an improvement in this respect and provide access to a high recycling regime. The radiation instability developing at high plasma densities in the helical divertor in TEXTOR is preceded by a transient partial detachment of the plasma from the divertor target plates and leads to the formation of a poloidally structured and helically inclined radiating belt, a helical divertor MARFE. While typically leading to a density limit disruption, this MARFE has been stabilised using a feedback system and could provide some divertor functionality such as low target temperature, increased neutral density and increased radiation within the stochastic boundary. Simulations using two different cross-field transport coefficients showed, that an agreement is only found at a certain level of cross-field transport (D perpendicular to =1 m 2 s -1 ). The inclusion of carbon impurities in the simulations results in the experimentally observed reduction of the recycling flux. (orig.)

  20. Experimental demonstration of vector E x vector B plasma divertor

    International Nuclear Information System (INIS)

    Strait, E.J.; Kerst, D.W.; Sprott, J.C.

    1977-01-01

    The vector E x vector B drift due to an applied radial electric field in a tokamak with poloidal divertor can speed the flow of plasma out of the scrape-off region, and provide a means of externally controlling the flow rate and thus the width of the density fall-off. An experiment in the Wisconsin levitated toroidal octupole, using vector E x vector B drifts alone, demonstrates divertor-like behavior, including 70% reduction of plasma density near the wall and 40% reduction of plasma flux to the wall, with no adverse effects on confinement of the main plasma

  1. Divertor conceptual designs for a fusion power plant

    International Nuclear Information System (INIS)

    Norajitra, P.; Ihli, T.; Janeschitz, G.; Abdel-Khalik, S.; Mazul, I.; Malang, S.

    2007-01-01

    The development of a divertor concept for post-ITER fusion power plants is deemed to be an urgent task to meet the EU Fast Track scenario. Developing a divertor is particularly challenging due to the wide range of requirements to be met including the high incident peak heat flux, the blanket design with which the divertor has to be integrated, sputtering erosion of the plasma-facing material caused by the incident a particles, radiation effects on the properties of structural materials, and efficient recovery and conversion of the divertor thermal power (∝15% of the total fusion thermal power) by maximizing the coolant operating temperature while minimizing the pumping power. In the course of the EU PPCS, three near-term (A, B and AB) and two advanced power plant models (C, D) were investigated. Model A utilizes a water-cooled lead-lithium (WCLL) blanket and a water-cooled divertor with a peak heat flux of 15 MW/m 2 . Model B uses a He-cooled ceramics/beryllium pebble bed (HCPB) blanket and a He-cooled divertor concept (10 MW/m 2 ). Model AB uses a He-cooled lithium-lead (HCLL) blanket and a He-cooled divertor concept (10 MW/m 2 ). Model C is based on a dual-coolant (DC) blanket (lead/lithium self-cooled bulk and He-cooled structures) and a He-cooled divertor (10 MW/m 2 ). Model D employs a self-cooled lead/lithium (SCLL) blanket and lead-lithiumcooled divertor (5 MW/m 2 ). The values in parenthesis correspond to the maximum peak heat fluxes required. It can be noted that the helium-cooled divertor is used in most of the EU plant models; it has also been proposed for the US ARIES-CS reactor study. Since 2002, it has been investigated extensively in Europe under the PPCS with the goal of reaching a maximum heat flux of at least 10 MW/m2. Work has covered many areas including conceptual design, analysis, material and fabrication issues, and experiments. Generally, the helium-cooled divertor is considered to be a suitable solution for fusion power plants, as it

  2. Latest status of manufacturing activity of ITER divertor and engineering issues on tungsten divertor

    International Nuclear Information System (INIS)

    Suzuki, Satoshi

    2011-01-01

    Divertors for ITER are now in construction. In the present chapter, the specification and the latest status of manufacturing of ITER divertors are presented. In addition, issues in the development of divertors for the fusion demo reactor are given on the basis of experiences on the ITER divertor development. (J.P.N.)

  3. Advanced divertor experiments on DIII-D

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Mahdavi, M.A.; Osborne, T.; Petrie, T.W.; Stambaugh, R.D.; Buchenauer, D.; Hill, D.N.; Klepper, C.C.

    1991-01-01

    The poloidal divertor is presently favored for next-step, high-power tokamaks. The DIII-D Advanced Divertor Program (ADP) aims to gain increased control over the divertor plasma and tokamak boundary conditions. This paper reports experiments done in the first phase of the ADP. The DIII-D lower divertor was modified by the addition of a toroidally symmetric, graphite-armoured, water-cooled divertor-biasing ring electrode at the entrance to a gas plenum. (In the past DIII-D operated with an open divertor.) The plenum will eventually contain a He cryogenic loop for active divertor pumping. The separatrix 'strike' position is controlled by the lower poloidal field shaping coils and can be varied smoothly from the ring electrode upper surface to the divertor floor far from the entrance aperture. External power, at up to 550 V and 8 kA separately, has been applied to the electrode to date. (author) 5 refs., 5 figs

  4. TCV divertor upgrade for alternative magnetic configurations

    Directory of Open Access Journals (Sweden)

    H. Reimerdes

    2017-08-01

    Full Text Available The Swiss Plasma Center (SPC is planning a divertor upgrade for the TCV tokamak. The upgrade aims at extending the research of conventional and alternative divertor configurations to operational scenarios and divertor regimes of greater relevance for a fusion reactor. The main elements of the upgrade are the installation of an in-vessel structure to form a divertor chamber of variable closure and enhanced diagnostic capabilities, an increase of the pumping capability of the divertor chamber and the addition of new divertor poloidal field coils. The project follows a staged approach and is carried out in parallel with an upgrade of the TCV heating system. First calculations using the EMC3-Eirene code indicate that realistic baffles together with the planned heating upgrade will allow for a significantly higher compression of neutral particles in the divertor, which is a prerequisite to test the power dissipation potential of various divertor configurations.

  5. Theory of Advanced Magnetic Divertors

    Science.gov (United States)

    Kotschenreuther, Michael; Valanju, Prashant; Mahajan, Swadesh; Covele, Brent

    2013-10-01

    The magnetic field structure in the SOL is the most important determinant of divertor physics. A comprehensive analytical and numerical methodology is developed to investigate SOL magnetic fields in the backdrop of two advanced divertor geometries- the X-divertor (XD) proposed and discussed in 2004, and the snowflake divertor (SFD) of 2007-2010. The analysis shows that XD and SFD represent very distinct and readily distinguishable magnetic geometries, epitomized through a differentiating metric, the Divertor Index (DI). In terms of this simple metric, the XD (DI > 1) and the SFD (DI XD flux surfaces are less convergent, in fact, divergent (flaring). These different SOL magnetics imply different physics, particularly with respect to detachment dynamics. It is also shown that some experiments on NSTX and DIII-D match both the prescription and the predictions of the 2004 XD paper. Work supported under US-DOE projects DE-FG02-04ER54742 and DE-FG02-04ER54754.

  6. The ITER divertor cassette project meeting

    International Nuclear Information System (INIS)

    Merola, M.; Riccardi, B.; Tivey, R.

    1999-01-01

    The Divertor Cassette Project topical meeting was held on May 26-28, 1999 at the ENEA Brasimone Research Centre in Camugnano (Bologna), Italy. Specialists from all the four Parties and the JCT participated in the meeting. It was concluded that the Divertor Cassette Project has significantly contributed to solving a large part of the critical issues of the ITER divertor design

  7. Divertor design through shape optimization

    International Nuclear Information System (INIS)

    Dekeyser, W.; Baelmans, M.; Reiter, D.

    2012-01-01

    Due to the conflicting requirements, complex physical processes and large number of design variables, divertor design for next step fusion reactors is a challenging problem, often relying on large numbers of computationally expensive numerical simulations. In this paper, we attempt to partially automate the design process by solving an appropriate shape optimization problem. Design requirements are incorporated in a cost functional which measures the performance of a certain design. By means of changes in the divertor shape, which in turn lead to changes in the plasma state, this cost functional can be minimized. Using advanced adjoint methods, optimal solutions are computed very efficiently. The approach is illustrated by designing divertor targets for optimal power load spreading, using a simplified edge plasma model (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. The magnetic vapour shield effect at divertor plates during plasma disruptions

    International Nuclear Information System (INIS)

    Piazza, G.; Goel, B.; Hoebel, W.; Wuerz, H.; Landman, I.

    1995-01-01

    Hard disruptions in a TOKAMAK cause a large thermal load on the divertor plates with an instantaneous ablation of a part of the heated material. The produced vapour cloud screens the plasma facing component from the direct interaction with the disrupting plasma (vapour shield effect). In order to quantify the damage to the divertor the magneto-hydrodynamic behaviour of the expanding vapour cloud has been investigated using an extended version of the 1-dimensional Lagrangian hydrodynamic code KATACO. Modelling of the magnetic field effects on the expanding plasma takes into account that the magnetic field is oblique to the divertor (1 1/2 dimensional model). The ''Radiation Heat Conduction Approximation'' has been used for describing the radiative energy transport. In this paper results are presented assuming graphite as divertor material, irradiated with a proton beam of an energy density of 12MJ/m 2 and a duration of 100μs. (orig.)

  9. Actively convected liquid metal divertor

    International Nuclear Information System (INIS)

    Shimada, Michiya; Hirooka, Yoshi

    2014-01-01

    The use of actively convected liquid metals with j × B force is proposed to facilitate heat handling by the divertor, a challenging issue associated with magnetic fusion experiments such as ITER. This issue will be aggravated even more for DEMO and power reactors because the divertor heat load will be significantly higher and yet the use of copper would not be allowed as the heat sink material. Instead, reduced activation ferritic/martensitic steel alloys with heat conductivities substantially lower than that of copper, will be used as the structural materials. The present proposal is to fill the lower part of the vacuum vessel with liquid metals with relatively low melting points and low chemical activities including Ga and Sn. The divertor modules, equipped with electrodes and cooling tubes, are immersed in the liquid metal. The electrode, placed in the middle of the liquid metal, can be biased positively or negatively with respect to the module. The j × B force due to the current between the electrode and the module provides a rotating motion for the liquid metal around the electrodes. The rise in liquid temperature at the separatrix hit point can be maintained at acceptable levels from the operation point of view. As the rotation speed increases, the current in the liquid metal is expected to decrease due to the v × B electromotive force. This rotating motion in the poloidal plane will reduce the divertor heat load significantly. Another important benefit of the convected liquid metal divertor is the fast recovery from unmitigated disruptions. Also, the liquid metal divertor concept eliminates the erosion problem. (letter)

  10. Snowflake divertor plasmas on TCV

    International Nuclear Information System (INIS)

    Piras, F; Coda, S; Furno, I; Moret, J-M; Sauter, O; Turri, G; Bencze, A; Duval, B P; Felici, F; Pochelon, A; Zucca, C; Pitts, R A; Tal, B

    2009-01-01

    Starting from a standard single null X-point configuration, a second order null divertor (snowflake (SF)) has been successfully created on the Tokamak a Configuration Variable (TCV) tokamak. The magnetic properties of this innovative configuration have been analysed and compared with a standard X-point configuration. For the SF divertor, the connection length and the flux expansion close to the separatrix exceed those of the standard X-point by more than a factor of 2. The magnetic shear in the plasma edge is also larger for the SF configuration.

  11. Progress in ergodic divertor operation on Tore Supra

    International Nuclear Information System (INIS)

    Ghendrih, Ph.; Becoulet, M.; Colas, L.; Grosman, A.; Guirlet, R.; Gunn, J.; Loarer, T.; Azeroual, A.; Basiuk, V.; Beaumont, B.; Becoulet, A.; Bremond, S.; Bucalossi, J.; Capes, H.; Corre, Y.; Costanzo, L.; Michelis, C. de; Devynck, P.; Feron, S.; Friant, C.; Garbet, X.; Giannella, R.; Grisolia, C.; Hess, W.; Hogan, J.; Ladurelle, L.; Laugier, F.; Martin, G.; Mattioli, M.; Meslin, B.; Monier-Garbet, P.; Moulin, D.; Nguyen, F.; Pascal, J.Y.; Pecquet, A.L.; Pegourie, B.; Reichle, R.; Saint-Laurent, F.; Vallet, J.C.; Zabiego, M.

    1999-09-01

    Upgrade of the Tore ergodic divertor has led to significant progress in ergodic divertor physics. The disruptive limit governed by the stochastization of the outer magnetic surfaces is found to occur for a value of the Chirikov parameter reaching 2 on the magnetic surface q = 2 + 3 / 12. This experimentally observed robustness allows one to operate at very low safety factor on the separatrix (q ∼ 2). Numerical analysis of ballooning turbulence in a stochastic layer indicates that the decay of the density fluctuations is in associated with an increase of the fluctuating electric drift velocity. The bottom line is then an enhanced cross-field transport in the vicinity of the target plates. This lowering of confinement appears to be compensated by an intrinsic transport barrier on the electron temperature. The 3-D response of the temperature field is computed with a fluid code. The intrinsic transport barrier at the separatrix, reported experimentally, can be recovered together with small amplitude temperature modulations in the divertor volume. Experimental evidence of the 3 density regimes (linear, high recycling and detachment) is reported. The low critical density values for these transitions indicate that similar parallel physics govern the axisymmetric and ergodic divertor, despite the open configuration of the latter. Measurement and understanding of these density regimes provide a means for feedback control of plasma density and an improvement in ICRH coupling scenarios. Experimental data also indicated that particle control with the vented target plates is effective. Increase of impurity control and radiation efficiency are recalled. Global power balance has been analysed. These results confirm the enhanced radiation capacity of the ergodic divertor. (author)

  12. Advanced divertor experiments on DIII-D

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Mahdavi, M.A.; Osborne, T.; Petrie, T.W.; Stambaugh, R.D.; Buchenauer, D.; Hill, D.N.; Klepper, C.C.

    1991-04-01

    The poloidal divertor is presently favored for next-step, high-power tokamaks. The DIII-D Advanced Divertor Program (ADP) aims to gain increased control over the divertor plasma and tokamak boundary conditions. This paper reports experiments done in the first phase of the ADP. The DIII-D lower divertor was modified by the addition of a toroidally symmetric, graphite-armoured, water-cooled divertor-biasing ring electrode at the entrance to a gas plenum. The plenum will eventually contain a He cryogenic loop for active divertor pumping. The separatrix ''strike'' position is controlled by the lower poloidal field shaping coils and can be varied smoothly from the ring electrode upper surface to the divertor floor far from the entrance aperture. External power, at up to 550 V and 8 kA separately, has been applied to the electrode to date. 5 refs., 5 figs

  13. Divertor Heat Flux Reduction and Detachment in the National Spherical Torus eXperiment.

    Science.gov (United States)

    Soukhanovskii, Vsevolod

    2007-11-01

    Steady-state handling of the heat flux is a critical divertor issue for both the International Thermonuclear Experimental Reactor and spherical torus (ST) devices. Because of an inherently compact divertor, it was thought that ST-based devices might not be able to fully utilize radiative and dissipative divertor techniques based on induced power and momentum loss. However, initial experiments conducted in the National Spherical Torus Experiment in an open geometry horizontal carbon plate divertor using 0.8 MA 2-6 MW NBI-heated lower single null H-mode plasmas at the lower end of elongations κ=1.8-2.4 and triangularities δ=0.45-0.75 demonstrated that high divertor peak heat fluxes, up to 6-10 MW/ m^2, could be reduced by 50-75% using a high-recycling radiative divertor regime with D2 injection. Furthermore, similar reduction was obtained with a partially detached divertor (PDD) at high D2 injection rates, however, it was accompanied by an X-point MARFE that quickly led to confinement degradation. Another approach takes advantage of the ST relation between strong shaping and high performance, and utilizes the poloidal magnetic flux expansion in the divertor region. Up to 60 % reduction in divertor peak heat flux was achieved at similar levels of scrape-off layer power by varying plasma shaping and thereby increasing the outer strike point (OSP) poloidal flux expansion from 4-6 to 18-22. In recent experiments conducted in highly-shaped 1.0-1.2 MA 6 MW NBI heated H-mode plasmas with divertor D2 injection at rates up to 10^22 s-1, a PDD regime with OSP peak heat flux 0.5-1.5 MW/m^2 was obtained without noticeable confinement degradation. Calculations based on a two point scrape-off layer model with parameterized power and momentum losses show that the short parallel connection length at the OSP sets the upper limit on the radiative exhaust channel, and both the impurity radiation and large momentum sink achievable only at high divertor neutral pressures are required

  14. Development of database for the divertor recycling in JT-60U and its analysis

    Energy Technology Data Exchange (ETDEWEB)

    Takizuka, Tomonori; Shimizu, Katsuhiro; Hayashi, Nobuhiko; Asakura, Nobuyuki [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Arakawa, Kazuya [Komatsu, Ltd., Tokyo (Japan)

    2003-05-01

    We have developed a database for the divertor recycling in JT-60U plasmas. This database makes it possible to investigate behaviors of the neutral-particle flux in plasmas and the ion flux to divertor plates under a condition for core-plasma parameters, such as electron density and heating power. The correlation between the electron density and the heating power is not strong in this database, and parameter scans for the density and the power in wide ranges are realized. On the basis of this database, we have analyzed the ion flux to divertor plates. The divertor-plate ion flux amplified by the recycling grows nonlinearly with the increase of the electron density n{sub e}. Its averaged dependence is a linear growth ({approx}n{sub e}{sup 1.0}) at the low density, and becomes a nonlinear growth ({approx}n{sub e}{sup 1.5}) at the high density. The spread of dependence from the averaged one is very large. This spread is caused mainly by complex physical characteristics of divertor plasmas, though it is little dependent on the heating power. The behavior of ion flux depends strongly on divertor configurations and divertor-plate/first-wall conditions. It is confirmed that the bifurcated transition takes place from the low-recycling divertor plasma at the low density to the high-recycling divertor plasma at the high density. The density at the transition is nearly proportional to the 1/4 power of the heating power. (author)

  15. Two-dimensional analysis for a scrapeoff and divertor regions with an MHD model

    International Nuclear Information System (INIS)

    Ueda, Noriaki; Kasai, Masao; Hitoki, Shigehisa

    1987-08-01

    With a two-dimensional time dependent fluid code for transport processes in the edge plasma in a tokamak, coupled with Monte-Carlo method for neutral gas behavior, preliminary numerical study has been carried out for the FER divertor. Design base data such as energy flux, particle flux and so on which are essentially important to make an divertor design reliable have been obtained. (author)

  16. Visible spectroscopy in the DIII-D divertor

    International Nuclear Information System (INIS)

    Brooks, N.H.; Fehling, D.; Hillis, D.L.; Klepper, C.C.; Naumenko, N.; Tugarinov, S.; Whyte, D.G.

    1996-06-01

    Spectroscopy measurements in the DIII-D divertor have been carried out with a survey spectrometer which provides simultaneous registration of the visible spectrum over the region 400--900 nm with a resolution of 0.2 nm. Broad spectral coverage is achieved through use of a fiberoptic transformer assembly to map the curved focal plane of a fast (f/3) Rowland spectrograph into a rastered format on the rectangular sensor area of a two-dimensional CCD camera. Vertical grouping of pixels during CCD readout integrates the signal intensity over the height of each spectral segment in the rastered image, minimizing readout time. For the full visible spectrum, readout time is 50 ms. Faster response time (< 10 ms) may be obtained by selecting for readout just a small number of the twenty spectral segments in the image on the CCD. Simultaneous recording of low charge states of carbon, oxygen and injected impurities has yielded information about gas recycling and impurity behavior at the divertor strike points. Transport of lithium to the divertor region during lithium pellet injection has been studied, as well as cumulative deposition of lithium on the divertor targets from pellet injection over many successive discharges

  17. Development of a compact W-shaped pumped divertor in JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, S.; Hosogane, N.; Masaki, K.; Kodama, K.; Sasajima, T.; Kishiya, K.; Takahashi, S.; Shimizu, K.; Akino, N.; Miyo, Y.; Hiratsuka, H.; Saidoh, M. [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment; Inoue, M.; Umakoshi, T.; Onozuka, M.; Morimoto, M. [Mitsubishi Heavy Industries, Wadasaki-cho, Hyogo-ku, Kobe-shi, 642 (Japan)

    1998-09-01

    In JT-60U, the modification to a W-shaped pumped divertor will be completed in May 1997, aiming to realize sufficient reduction in heat flux to the targets and good H-mode confinement simultaneously. W-shaped geometry is optimized not only for forming radiative divertor plasmas and reducing the back flow of neutral particles but also for allowing various experimental configurations. Toroidally and poloidally segmented divertor plates, dome and baffles are arranged in a W-shaped poloidal configuration. The pumping speed can be changed during a shot by variable shutter valves in the three pumping ports under the outer baffle. The net throughput is enough for particle control in the steady radiative operations with high power NBI heating. Carbon fiber composite (CFC) tiles are used for the divertor targets and the divertor throat where large heat flux is expected. Gaps between two adjacent segments are carefully sealed to suppress the leak of neutral gas from the exhaust duct below the divertor and baffles. The strength of the whole structure is confirmed by an electromagnetic force analysis and structural analysis carried out for disruptions of 3 MA discharges with a halo current. (orig.) 11 refs.

  18. Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake

    International Nuclear Information System (INIS)

    Kotschenreuther, Mike; Valanju, Prashant; Covele, Brent; Mahajan, Swadesh

    2013-01-01

    Advanced divertors are magnetic geometries where a second X-point is added in the divertor region to address the serious challenges of burning plasma power exhaust. Invoking physical arguments, numerical work, and detailed model magnetic field analysis, we investigate the magnetic field structure of advanced divertors in the physically relevant region for power exhaust—the scrape-off layer. A primary result of our analysis is the emergence of a physical “metric,” the Divertor Index DI, which quantifies the flux expansion increase as one goes from the main X-point to the strike point. It clearly separates three geometries with distinct consequences for divertor physics—the Standard Divertor (DI = 1), and two advanced geometries—the X-Divertor (XD, DI > 1) and the Snowflake (DI < 1). The XD, therefore, cannot be classified as one variant of the Snowflake. By this measure, recent National Spherical Torus Experiment and DIIID experiments are X-Divertors, not Snowflakes

  19. Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake

    Energy Technology Data Exchange (ETDEWEB)

    Kotschenreuther, Mike; Valanju, Prashant; Covele, Brent; Mahajan, Swadesh [Institute for Fusion Studies, The University of Texas at Austin, Austin, Texas 78712 (United States)

    2013-10-15

    Advanced divertors are magnetic geometries where a second X-point is added in the divertor region to address the serious challenges of burning plasma power exhaust. Invoking physical arguments, numerical work, and detailed model magnetic field analysis, we investigate the magnetic field structure of advanced divertors in the physically relevant region for power exhaust—the scrape-off layer. A primary result of our analysis is the emergence of a physical “metric,” the Divertor Index DI, which quantifies the flux expansion increase as one goes from the main X-point to the strike point. It clearly separates three geometries with distinct consequences for divertor physics—the Standard Divertor (DI = 1), and two advanced geometries—the X-Divertor (XD, DI > 1) and the Snowflake (DI < 1). The XD, therefore, cannot be classified as one variant of the Snowflake. By this measure, recent National Spherical Torus Experiment and DIIID experiments are X-Divertors, not Snowflakes.

  20. Divertor plasma modification by divertor biasing and edge ergodization in JFT-2M

    International Nuclear Information System (INIS)

    Shoji, T.; Nagashima, K.; Tamai, H.; Ohdachi, S.; Miura, Y.; Ohasa, K.; Maeda, H.; Ohyabu, N.; Leonard, A.W.; Aikawa, H.; Fujita, T.; Hoshino, K.; Kawashima, H.; Matsuda, T.; Maeno, M.; Mori, M.; Ogawa, H.; Shimada, M.; Uehara, K.; Yamauchi, T.

    1995-01-01

    The effects of divertor biasing and edge ergodization on the divertor plasma have been investigated in the JFT-2M tokamak. Experimental results show; (1) The differential divertor biasing can change the in/out asymmetry of the divertor plasma. It especially changes the density on the ion side divertor plasma. The in/out electron pressure difference has a good correlation with the biasing current. (2) The unipolar divertor biasing can change the density profile of divertor plasma. The radial electric field and shear flow are the cause for this change. (3) The electron temperature of the divertor plasma in the H-mode with frequent ELMs induced by edge ergodization is lower than that of usual H-mode. That is due to the enhancement of the radial particle flux by frequent ELMs, ((orig.))

  1. Fabrication of divertor cassette for ITER

    International Nuclear Information System (INIS)

    Sanguinetti, G.P.

    2008-01-01

    The Divertor is the component located on the bottom of the ITER vacuum vessel, whose main function is to adsorb the high thermal flux generated by the plasma whilst keeping the plasma impurity at a reasonable low level. The divertor consist of 54 units, each comprising outer components, facing the plasma and a component supporting the plasma facing components (PFC) and providing coolant distribution to them (divertor cassette). The divertor cassette is a box structure, butt welded and machined, made from plates and forgins of austenitic stainless steels. The cassette fabrication, which is in detail described, includes manufacturing of the attachments of the PFC to the cassette, the coolant distribution channels, and the cassette to vacuum vessel locking system. The divertor cassette is a pressure component (the cooling water runs at 40 bar) and therefore divertor cassette design, fabrication and service shall comply with the European PED and the applicable French law for the ITER. (orig.)

  2. A Lithium Vapor Box Divertor Similarity Experiment

    Science.gov (United States)

    Cohen, Robert A.; Emdee, Eric D.; Goldston, Robert J.; Jaworski, Michael A.; Schwartz, Jacob A.

    2017-10-01

    A lithium vapor box divertor offers an alternate means of managing the extreme power density of divertor plasmas by leveraging gaseous lithium to volumetrically extract power. The vapor box divertor is a baffled slot with liquid lithium coated walls held at temperatures which increase toward the divertor floor. The resulting vapor pressure differential drives gaseous lithium from hotter chambers into cooler ones, where the lithium condenses and returns. A similarity experiment was devised to investigate the advantages offered by a vapor box divertor design. We discuss the design, construction, and early findings of the vapor box divertor experiment including vapor can construction, power transfer calculations, joint integrity tests, and thermocouple data logging. Heat redistribution of an incident plasma-based heat flux from a typical linear plasma device is also presented. This work supported by DOE Contract No. DE-AC02-09CH11466 and The Princeton Environmental Institute.

  3. Nanocomposites - mechanical behavior and radiation effects

    International Nuclear Information System (INIS)

    Misra, A.; Hoagland, R.G.; Nastasi, M.; Demkowicz, M.J.; Zhang, X.

    2009-01-01

    The combination of high strength and high radiation damage tolerance in nanolaminate composites can be achieved when the individual layers in these composites are only a few nanometers thick and therefore these materials contain a large volume fraction associated with interfaces. These interfaces act both as obstacles to slip, as well as sinks for radiation-induced defects. The morphological and phase stabilities of these nano-composites under ion irradiation are explored as a function of layer thickness, temperature and interface structure. Using results on model systems such as Cu-Nb, we highlight the critical role of the atomic structure of the incoherent interfaces that exhibit multiple states with nearly degenerate energies in acting as sinks for radiation-induced point defects. Reduced radiation damage also leads to a reduction in the irradiation hardening, particularly at layer thickness of approximately 5 nm and below. The strategies for design of radiation-tolerant structural materials based on the knowledge gained from this work will be discussed. (au)

  4. The ITER divertor cassette project

    International Nuclear Information System (INIS)

    Ulrickson, M.; Tivey, R.; Akiba, M.

    2001-01-01

    The divertor ''Large Project'' was conceived with the aim of demonstrating the feasibility of meeting the lifetime requirements by employing the candidate armor materials of beryllium, tungsten (W) and carbon-fiber-composite (CFC). At the start, there existed only limited experience with constructing water-cooled high heat flux armored components for tokamaks. To this was added the complication posed by the need to use a silver-free joining technique that avoids the transmutation of n-irradiated silver to cadmium. The research project involving the four Home Teams (HTs) has focused on the design, development, manufacture and testing of full-scale Plasma Facing Components (PFCs) suitable for ITER. The task addressed all the issues facing ITER divertor design, such as providing adequate armor erosion lifetime, meeting the required armor-heat sink joint lifetime and heat sink fatigue life, sustaining thermal-hydraulic and electromechanical loads, and seeking to identify the most cost-effective manufacturing options. This paper will report the results of the divertor large project. (author)

  5. The ITER divertor cassette project

    International Nuclear Information System (INIS)

    Ulrickson, M.; Tivey, R.; Akiba, M.

    1999-01-01

    The divertor 'Large Project' was conceived with the aim of demonstrating the feasibility of meeting the lifetime requirements by employing the candidate armor materials of beryllium, tungsten (W) and carbon-fiber-composite (CFC). At the start, there existed only limited experience with constructing water-cooled high heat flux armored components for tokamaks. To this was added the complication posed by the need to use a silver-free joining technique that avoids the transmutation of n-irradiated silver to cadmium. The research project involving the four Home Teams (HTs) has focused on the design, development, manufacture and testing of full-scale Plasma Facing Components (PFCs) suitable for ITER. The task addressed all the issues facing ITER divertor design, such as providing adequate armor erosion lifetime, meeting the required armor-heat sink joint lifetime and heat sink fatigue life, sustaining thermal-hydraulic and electromechanical loads, and seeking to identify the most cost-effective manufacturing options. This paper will report the results of the divertor large project. (author)

  6. Divertor plate for thermonuclear reactor

    International Nuclear Information System (INIS)

    Yamazaki, Seiichiro; Sato, Keisuke; Nishio, Satoshi.

    1993-01-01

    In a divertor plate for a thermonuclear reactor, adjacent cooling pipes are electrically insulated from each other and pipes made of a gradient functional material prepared by compositing ceramics having an insulation property and metals are metallurgically joined to at least one portion of each of the cooling pipes. Electric current caused upon occurrence of plasma disruption is interrupted by the insulation portion, so that a large circuit is not formed and electromagnetic force is decreased to such a extent that the divertor plate is not ruptured. Since a header of the cooling pipes can be installed at any optional position, the installation space can be reduced. Further, since inlet and exit collection headers can be disposed on both ends of the cooling pipes, it is possible to shorten the length of the cooling pipe of the divertor plate corresponded to high heat fluxes and reduce the pressure loss on the side of coolants to about 1/2. Further, turn back portions of small radius of curvature of the cooling pipes are eliminated to reduce the cost and extend the lifetime and, in addition, protection tiles can be attached easily. (N.H.)

  7. The lithium vapor box divertor

    International Nuclear Information System (INIS)

    Goldston, R J; Schwartz, J; Myers, R

    2016-01-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m −2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma. (paper)

  8. Evaluation of copper alloys for fusion reactor divertor and first wall components

    DEFF Research Database (Denmark)

    Fabritsiev, S.A.; Zinkle, S.J.; Singh, B.N.

    1996-01-01

    This paper presents a critical analysis of the main factors of radiation damage limiting the possibility to use copper alloys in the ITER divertor and first wall structure. In copper alloys the most significant types of radiation damage in the proposed temperature-dose operation range are swellin...

  9. Power components behavior under nuclear radiations

    International Nuclear Information System (INIS)

    Jaureguy, J.C.; Azais, B.

    1989-01-01

    Many apparatus, either fixed or on-board of vehicles, use power converters. The most common scheme includes chopper with bipolar transistors. In case of nuclear radiations, these equipments may be severely damaged. Depending on the disturbance level, the need for changes in power transistor technology has to be considered or not [fr

  10. Thermal strain measurement of EAST W/Cu divertor structure using electric resistance strain gauges

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xingli [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Wang, Wanjing, E-mail: wjwang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Wang, Jichao [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Wei, Ran; Sun, Zhaoxuan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Li, Qiang; Xie, Chunyi [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Chen, Hong-En; Wang, Kaiqiang; Wu, Lei; Chen, Zhenmao [State Key Lab for Strength and Vibration of Mechanical Structures, Xi’an Jiaotong University (China); Luo, Guang-Nan [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031 (China); Science Island Branch of Graduate School, University of Science & Technology of China, Hefei, 230031 (China); Hefei Center for Physical Science and Technology, Hefei, 230022 (China); Hefei Science Center of Chinese Academy of Sciences, Hefei, 230027 (China)

    2016-12-15

    Highlights: • To understand the service behavior of W/Cu divertor, an electrical resistance strain gauge system had been introduced in a thermal strain measurement experiment. • The measurement system successfully finished the experiment and obtained valued thermal strain data. • Two thermomechanical analyses had also been carried out and compared with the measurement results. • Experiment results corresponded well to simulations and threw a light upon the failure of W/Cu divertor in the previous baking tests. - Abstract: W/Cu divertor has complex structure and faces extreme work environment in EAST Tokamak device. To measure its thermal strain shall be a valued way to understand its service behavior and then optimize its design and manufacturing process. This work presents a preliminary study on measuring thermal strain of EAST W/Cu divertor structure using electric resistance strain gauges. Eight gauges had been used in the experiment and the heating temperature had been set to 230 °C with respect to the work temperature. To realize the measuring experiment, an appropriate fixing method of gauges in divertor narrow spaces had been taken and tested, which could not only withstand high temperature but also had no damage to the divertor sample. The measurement results were that three gauges showed positive strain while other three showed negative strain after having been compensated, which corresponded to tensile stress and compressed stress respectively. Two thermomechanical simulations had also been carried out and used for comparing with the experiment.

  11. Divertor extreme ultraviolet (EUV) survey spectroscopy in DIII-D

    Science.gov (United States)

    McLean, Adam; Allen, Steve; Ellis, Ron; Jarvinen, Aaro; Soukhanovskii, Vlad; Boivin, Rejean; Gonzales, Eduardo; Holmes, Ian; Kulchar, James; Leonard, Anthony; Williams, Bob; Taussig, Doug; Thomas, Dan; Marcy, Grant

    2017-10-01

    An extreme ultraviolet spectrograph measuring resonant emissions of D and C in the lower divertor has been added to DIII-D to help resolve an 2X discrepancy between bolometrically measured radiated power and that predicted by boundary codes for DIII-D, JET and ASDEX-U. With 290 and 450 gr/mm gratings, the DivSPRED spectrometer, an 0.3 m flat-field McPherson model 251, measures ground state transitions for D (the Lyman series) and C (e.g., C IV, 155 nm) which account for >75% of radiated power in the divertor. Combined with Thomson scattering and imaging in the DIII-D divertor, measurements of position, temperature and fractional power emission from plasma components are made and compared to UEDGE/SOLPS-ITER. Mechanical, optical, electrical, vacuum, and shielding aspects of DivSPRED are presented. Work supported under USDOE Cooperative Agreement DE-FC02-04ER54698 and DE-AC52-07NA27344, and by the LLNL Laboratory Directed R&D Program, project #17-ERD-020.

  12. SOLPS simulations of X-divertor in NSTX-U

    Science.gov (United States)

    Chen, Zhongping; Kotschenreuther, Mike; Mahajan, Swadesh

    2017-10-01

    The X-divertor (XD) geometry in NSTX-U has demonstrated, in SOLPS simulations, a better performance than the standard divertor (SD) regarding detachment: achieving detachment with a lower upstream density and stabilizing the detachment front near the target. The benefits of such a localized front is that the power exhaust requirement can be satisfied without the radiation front encroaching on the core plasma. It is also found by our simulations that at similar states of detachment the XD outperforms the SD by reducing the heat fluxes to the target and maintaining higher upstream temperatures. These advantages are attributed to the unique geometric characteristics of XD - poloidal flaring near the target. The detailed physical mechanisms behind the better XD performance that is found in the simulations will be examined. Work supported by US DOE under DE-FG02-04ER54742 and SC 0012956.

  13. Model of divertor biasing and control of scrape-off layer and divertor plasmas

    International Nuclear Information System (INIS)

    Nagasaki, K.; Itoh, K.; Itoh, S.

    1991-02-01

    Analytic model of the divertor biasing is described. For the given plasma and energy sources from the core plasma, the heat and particle flux densities on the divertor plate as well as scrape-off-layer (SOL)/divertor plasmas are analyzed in a slab model. Using a two-dimensional model, the effects of the divertor biasing and SOL current are studied. The conditions to balance the plasma temperature or sheath potential on different divertor plates are obtained. Effect of the SOL current on the heat channel width is also discussed. (author)

  14. Behavior of MOSFET Amplifier in Radiation Fields

    International Nuclear Information System (INIS)

    Sharshar, K.A.A.; Ashry, M.

    2000-01-01

    MOSFET type 2 N 3823 characteristics and its application as an amplifier are analyzed including the effects of gamma, electron beam 1.5 MeV 25 m A and neutron flux. The 1-V characteristics, transfer curve, and the frequency response of the amplifier, and the amplification factor(A v 0 are discussed with MOSFET circuit parameters. The drain current and the amplitude of the output signal decrease as the absorbed dose increases. The measured values of the amplified signal are attenuated by 30% and 6% after exposing the MOSFET to gamma radiation and electron beam at the same dose respectively. Also for exposure to 4x10 13 N/cm 3 neutrons decreased the measured value of the amplified signal by 73% of the initial values. The decrease in the gain of the MOSFET is due to the degradation of the transconductance. It is also noticed that percentage of the decrease depends on the type of radiation

  15. Engineering conceptual design of CFETR divertor

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Xuebing, E-mail: pengxb@ipp.cas.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Ye, Minyou [School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China); Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Song, Yuntao [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China); Mao, Xin [Institute of Plasma Physics, Chinese Academy of Sciences, Shushanhu Road 350, 230031 Hefei Anhui (China); Chen, Peiming; Qian, Xinyuan [School of Nuclear Science and Technology, University of Science and Technology of China, Jinzhai Road 96, 230026 Hefei Anhui (China)

    2015-10-15

    Highlights: • Three divertor structures for two plasma configurations, ITER-like and snowflake. • Property of enlarging wet area for all three divertors is analyzed. • The divertor accommodating with both the plasma configurations is unfeasible. • Divertor cooling system is developed. - Abstract: The China Fusion Engineering Test Reactor (CFETR), which is in conceptual design phase, aims at producing fusion power of 50–200 MW with tritium breeding ratio of ∼1.2 and duty cycle time of 0.3–0.5. Its designed main parameters are major/minor radii of 5.7 m/1.6 m and plasma current of 10 MA. Although the fusion power is lower than the one of ITER, the relative smaller machine dimensions and planed much higher auxiliary heating power of 100–140 MW make that the power exhausting for the CFETR divertor is a very critical issue. To solve this issue, the divertor should be better designed with advanced physical operation mode, advanced configuration/geometry or high efficient cooling structure. In the paper, much effort was put on the divertor configuration and geometry. With designed magnet system, three divertor configurations can be realized, ITER-like, snowflake and super-X. However, considering structural design feasibility and remote handling compatibility, only the first two configurations were selected for the first step of engineering design. Three divertors were designed. They have different first wall geometries to accommodate with different plasma configurations, one for the ITER-like, one for the snowflake and the third one for both the configurations. All three divertors employ the same cassette body as the support and the cooling water manifold for the first wall. This feature simplifies the interface of the divertor to other components in the vacuum vessel. Besides, the cooling structure and the remote maintenance concept are also introduced in the paper.

  16. A large divertor manipulator for ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Albrecht, E-mail: albrecht.herrmann@ipp.mpg.de; Jaksic, Nikola; Leitenstern, Peter; Greuner, Henri; Krieger, Karl; Marné, Pascal de; Oberkofler, Martin; Rohde, Volker; Schall, Gerd

    2015-10-15

    Highlights: • A large divertor manipulator for ASDEX Upgrade is developed and tested. • It allows replacing a relevant part of the divertor by dedicated targets and probes. • Modified solid standard targets. • Electrical and mechanical probes for dedicated investigations. • Test of actively cooled component. - Abstract: In 2013 a new bulk tungsten divertor, Div-III, was installed in ASDEX Upgrade (AUG). During the concept and design phase of Div-III the option of adaptable divertor instrumentation and divertor modification as contribution for divertor investigations in preparation of ITER was given a high priority. To gain flexibility for the test of divertor modifications without affecting the operational space of AUG, the large divertor manipulator, DIM-II, was designed and installed. DIM-II allows to retract 2 out of 128 outer divertor target tiles including the water cooled support structure into a target exchange box and to replace these targets without breaking the vacuum of the AUG vessel. DIM-II is based on a carriage-rail system with a driving rod pushing a front-end with the target module into the divertor position for plasma operation. Three types of front-ends are foreseen for physics investigations: (i) modified standard targets clamped to the standard cooling structure, (ii) dedicated front-ends making use of the whole available volume of about 230 × 160 × 80 mm{sup 3} and (iii) actively cooled/heated targets for cooling water temperatures up to 230 °C. This paper presents the DIM-II design including the FEM calculations for the modified divertor support structure and the front-end options, as well as the test procedure and operation mode.

  17. Effects of the New Island Divertor on the Plasma Performance in the W7-AS Stellarator

    International Nuclear Information System (INIS)

    Grigull, P.; McCormick, K.; Baldzuhn, J.; Burhenn, R.; Brakel, R.; Ehmler, H.; Feng, Y.; Gadelmeier, F.; Giannone, L.; Hartmann, D.; Hildebrandt, D.; Hirsch, M.; Jaenicke, R.; Kisslinger, J.; Klinger, T.; Knauer, J.; Koenig, R.; Naujoks, D.; Niedermeyer, H.; Pasch, E.

    2003-01-01

    The island divertor in the W7-AS stellarator enables access to a new NBI-heated, high density operating regime with promising confinement properties. This regime -- the High Density H-Mode -- displays no evident mode activity, is extant above a threshold density and characterized by flat density profiles, high energy- and low impurity-confinement times and edge localized radiation. Impurity accumulation, normally associated with ELM-free H-modes, is avoided. Quasi steady-state discharges with n e up to 4 1020 m-3, edge radiation levels up to 90%, and partial plasma detachment at the divertor targets can be simultaneously realized

  18. Moving Divertor Plates in a Tokamak

    International Nuclear Information System (INIS)

    Zweben, S.J.; Zhang, H.

    2009-01-01

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions

  19. Optimization of a bundle divertor for FED

    International Nuclear Information System (INIS)

    Hively, L.M.; Rothe, K.E.; Minkoff, M.

    1982-01-01

    Optimal double-T bundle divertor configurations have been obtained for the Fusion Engineering Device (FED). On-axis ripple is minimized, while satisfying a series of engineering constraints. The ensuing non-linear optimization problem is solved via a sequence of quadratic programming subproblems, using the VMCON algorithm. The resulting divertor designs are substantially improved over previous configurations

  20. Moving Divertor Plates in a Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  1. Stability of tokamak magnetic configuration with a poloidal divertor

    International Nuclear Information System (INIS)

    Bazaeva, A.V.; Bykov, V.E.; Georgievskii, A.V.; Kaminskii, A.O.; Peletminskaya, V.G.; Pyatov, V.H.

    1979-02-01

    This paper investigates instabilities in the preseparatrix region of a tokamak magnetic configuration with a poloidal divertor with respect to perturbations produced by various irregularities in the manufacturing of tokamak magnetic systems. A computer solution, a system of differential equations describing the behavior of a force line, showed that small perturbation amplitudes may be the cause of the stochastic instability of force lines in the preseparatrix region. This instability is responsible for a number of demands on the accuracy in the manufacturing of tokamak magnetic systems. In particular, the misalignment in the divertor ring must not be larger than 0.5 0 , its displacement must be less than Δ/R = 10 -2 (Δ/R -2 ). This study can be used in the design of large thermonuclear installations

  2. Rapidly Moving Divertor Plates In A Tokamak

    International Nuclear Information System (INIS)

    Zweben, S.

    2011-01-01

    It may be possible to replace conventional actively cooled tokamak divertor plates with a set of rapidly moving, passively cooled divertor plates on rails. These plates would absorb the plasma heat flux with their thermal inertia for ∼10-30 sec, and would then be removed from the vessel for processing. When outside the tokamak, these plates could be cooled, cleaned, recoated, inspected, and then returned to the vessel in an automated loop. This scheme could provide nearoptimal divertor surfaces at all times, and avoid the need to stop machine operation for repair of damaged or eroded plates. We describe various possible divertor plate designs and access geometries, and discuss an initial design for a movable and removable divertor module for NSTX-U.

  3. Reactor application of an improved bundle divertor

    International Nuclear Information System (INIS)

    Yang, T.F.; Ruck, G.W.; Lee, A.Y.; Smeltzer, G.; Prevenslik, T.

    1978-11-01

    A Bundle Divertor was chosen as the impurity control and plasma exhaust system for the beam driven Demonstration Tokamak Hybrid Reactor - DTHR. In the context of a preconceptual design study of the reactor and associated facility a bundle divertor concept was developed and integrated into the reactor system. The overall system was found feasible and scalable for reactors with intermediate torodial field strengths on axis. The important design characteristics are: the overall average current density of the divertor coils is 0.73 kA for each tesla of toroidal field on axis; the divertor windings are made from super-conducting cables supported by steel structures and are designed to be maintainable; the particle collection assembly and auxiliary cryosorption vacuum pump are dual systems designed such that they can be reactivated alterntively to allow for continuous reactor operation; and the power requirement for energizing and operating the divertor is about 5 MW

  4. Comparison between stellarator and tokamak divertor transport

    International Nuclear Information System (INIS)

    Feng, Y.; Lunt, T.; Kobayashi, M.; Reiter, D.

    2010-11-01

    The paper compares the essential divertor transport features of the poloidal divertor, which is well-developed for tokamaks, and the non-axisymmetric divertors currently investigated on helical devices. It aims at surveying the fundamental similarities and differences in divertor concept and geometry, and their consequences for how the divertor functions. In particular, the importance of various transport terms governing axisymmetric and helical scrape-off-layers (SOLs) is examined, with special attention being paid to energy, momentum and impurity transport. Tokamak and stellarator SOLs are compared by identifying key geometric parameters through which the governing physics can be illustrated by simple models and estimates. More quantitative assessments rely nevertheless on the modeling using EMC3-EIRENE code. Most of the theoretical results are discussed in conjunction with experimental observations. (author)

  5. Snowflake divertor experiments on TCV

    International Nuclear Information System (INIS)

    Piras, F; Coda, S; Duval, B P; Labit, B; Marki, J; Moret, J-M; Pitzschke, A; Sauter, O; Medvedev, S Yu

    2010-01-01

    An ELMy H-mode 'snowflake' (SF) divertor is established and studied for the first time in the TCV tokamak. The H-mode access and the edge localized mode (ELM) dynamics are compared with a conventional single-null diverted configuration. The SF configuration exhibits 15% higher confinement and 2-3 times lower ELM frequency. Ideal MHD stability analysis suggests enhanced stability of the SF H-mode pedestal to mid- to high-toroidal-mode-number modes. The capability of the SF to redistribute the edge power on the additional strike points has been confirmed experimentally.

  6. The effect of feedback-controlled divertor nitrogen seeding on the boundary plasma and power exhaust channel width in Alcator C-Mod

    Science.gov (United States)

    Labombard, B.; Brunner, D.; Kuang, A. Q.; McCarthy, W.; Terry, J. L.

    2017-10-01

    The scrape-off layer (SOL) power channel width, λq, is projected to be 0.5 mm in power reactors, based on multi-machine measurements of divertor target heat fluxes in H-mode at low levels of divertor dissipation. An important question is: does λq change with the level of divertor dissipation? We report results in which feedback controlled nitrogen seeding in the divertor was used to systematically vary divertor dissipation in a series of otherwise identical L-mode plasmas at three plasma currents: 0.55, 0.8 and 1.1 MA. Outer midplane profiles were recorded with a scanning Mirror Langmuir Probe; divertor plasma conditions were monitored with `rail' Langmuir probe and surface thermocouple arrays. Despite an order of magnitude reduction in divertor target heat fluxes (q// 400 MW m-2 to 40 MW m-2) and corresponding change in divertor regime from sheath-limited through high-recycling to near-detached, the upstream electron temperature profile is found to remain unchanged or to become slightly steeper in the near SOL and to drop significantly in the far SOL. Thus heat in the SOL appears to take advantage of this impurity radiation `heat sink' in the divertor by preferentially draining via the narrow (and perhaps an increasingly narrow) λq of the near SOL. Supported by USDoE award DE-FC02-99ER54512.

  7. Heat removal capability of divertor coaxial tube assembly

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    To deal with high power flowing in the divertor region, an advanced divertor concept with gas target has been proposed for use in ITER/EDA. The concept uses a divertor channel to remove the radiated power while allowing neutrals to recirculate. Candidate channel wall designs include a tube array design where many coaxial tubes are arranged in the toroidal direction to make louver. The coaxial tube consists of a Be protection tube encases many supply tubes wound helically around a return tube. V-alloy and hardened Cu-alloy have been proposed for use in the supply and return tubes. Some coolants have also been proposed for the design including pressurized He and liquid metals, because these coolants are consistent with the selection of coolants for the blanket and also meet the requirement of high temperature operation. In the coaxial tube design, the coolant area is restricted and brittle Be material is used under severe thermal cyclings. Thus, to obtain the coaxial tube with sufficient safety margin for the expected fusion power excursion, it is essential to understand its applicability limit. The paper discusses heat removal capability of the coaxial tube and recommends some design modifications. (author)

  8. Particle recirculation in the ergodic divertor of Tore Supra

    International Nuclear Information System (INIS)

    Gunn, J.P.; Azeoual, A.; Becoulet, M.

    1999-01-01

    The present paper addresses the issue of particle recirculation in discharges where low energy flux to ergodic divertor target plates is achieved, in highly radiating detached ohmic plasmas. Plasma temperature and particle flux are measured by flush-mounted probes in the divertor plates, and by an upstream fast scanning Mach probe. The scalings with core density of the ion flux and electron temperature are well described by the simple two-point model used in axisymmetric poloidal divertors. The detachment signature is a pressure drop that occurs when the edge temperature falls below 10 eV. The parallel ion flux gradient is always positive, indicating that recombination is unlikely to play an important role in detachment. Visible spectroscopy of a neutralizer plate shows that attainment of cold detached plasmas near the density limit coincides with an abrupt increase of fueling for both deuterium and impurities. A feedback algorithm based on real time Langmuir probe measurements has been developed to monitor detachment and avoid disruptions. (authors)

  9. Operating windows of pebble divertor

    International Nuclear Information System (INIS)

    Matsuhiro, K.; Isobe, M.; Ohtsuka, Y.; Ueda, Y.; Nishikawa, M.

    2001-01-01

    A marked feature of the pebble divertor is an effect by use of functional multi-layer coated pebble, which consists of a surface plasma facing layer, an intermediate tritium permeation barrier layer, and a kernel for heat removal. The dimensions, structure and the irradiation conditions of pebbles are the important issues for the development of the pebble divertor. From the view point of resistance of the induced thermal stress, the pebble is taken as small as possible in size. On the other hand, from the view point of the pumping performance, the suitable irradiation temperature range of the surface layer of pebble was estimated from the experiments and the numerical analysis. The pumping process enhanced by dynamic retention is available to extend the higher allowable irradiation temperature range from 900K to 1100K. As taking the temperature rise limitation due to pumping effect and the fractural strength due to the induced thermal stress limitation, it was found that the diameter of the pebble is possible to be 1-2 mm in about 20 MW/m 2 for the SiC kernel and 2-3 mm in less than 30 MW/m 2 for the graphite kernel. (author)

  10. Multiple equilibria of divertor plasmas

    International Nuclear Information System (INIS)

    Vu, H.X.; Prinja, A.K.

    1993-01-01

    A one-dimensional, two-fluid transport model with a temperature-dependent neutral recycling coefficient is shown to give rise to multiple equilibria of divertor plasmas (bifurcation). Numerical techniques for obtaining these multiple equilibria and for examining their stability are presented. Although these numerical techniques have been well known to the scientific community, this is the first time they have been applied to divertor plasma modeling to show the existence of multiple equilibria as well as the stability of these solutions. Numerical and approximate analytical solutions of the present one-dimensional transport model both indicate that there exists three steady-state solutions corresponding to (1) a high-temperature, low-density equilibrium, (2) a low-temperature, high-density equilibrium, and (3) an intermediate-temperature equilibrium. While both the low-temperature and the high-temperature equilibria are stable, with respect to small perturbations in the plasma conditions, the intermediate-temperature equilibrium is physically unstable, i.e., any small perturbation about this equilibrium will cause a transition toward either the high-temperature or low-temperature equilibrium

  11. Behavior of clay materials under ionizing radiation

    International Nuclear Information System (INIS)

    Laine, Maxime

    2017-01-01

    The aim of this PhD thesis is to study and understand, by proposing reaction mechanisms, the behavior under irradiation of various clay materials. The systems of interest were first synthetic talc, which is the prototype of a non-swelling material. Under irradiation by accelerated electrons, the production of dihydrogen in this system, due solely to surface hydroxyl groups, is of the same order of magnitude as the one obtained in liquid water. This yield is divided by 30 in the case of natural talc from Luzenac, thus highlighting the importance of the impurities as scavengers of the precursors of dihydrogen. Synthetic smectites, which are swelling materials, were then studied. The results evidence the radiolysis of water confined in the interlayer space, leading to H 2 yields which may be two to three times higher than those measured in water. Moreover, they are similar for montmorillonite and saponite, evidencing that the charge location plays only a minor role. Finally, the study of double layered hydroxides or anionic clays shows that, in this case, the nature of the anion in the inter lamellar space controls the reactivity. Parallel to these measurements, electron paramagnetic spectroscopy experiments have enabled proposing reaction mechanisms. Finally, all these results are of interest in the context of the disposal of radioactive waste. (author) [fr

  12. Design of DIII-D advanced divertor

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Reis, E.; Schaffer, M.; Thruston, G.

    1989-01-01

    The Advanced Divertor is a modification being designed for the plasma chamber of the DIII-D tokamak in order to optimize the divertor configuration and allow a broader range of experiments to be carried out. The Advanced Divertor will enable two classes of physics experiments to be run in DIII-D: Divertor biasing and Divertor baffing. The Advanced Divertor has two principal components: ( 1) a toroidally symmetric baffle; and (2) a continuous ring electrode. The tokamak can be run in baffle, bias, or standard DIII-D divertor modes by accurate positioning of the outer divertor strike point through the use of the DIII-D plasma control system. The baffle will contain approximately 50,000 l/s pumping for particle removal in the outer bottom corner of the vacuum vessel. The strike point will be positioned at the entrance aperture for the baffle mode. The aperture geometry is designed to facilitate a large particle influx plus a high probability that backstreaming particles will be reionized and redirected to the aperture. Where the baffling plates meet, gas sealing is required to prevent recycling of neutrals back into the plasma. The electrode is a continuous water-cooled ring, armored with graphite. The ring is electrically isolated from the vessel wall and is biasable to 1 kV and 20 kA. The outer leg of the divertor will be positioned on the graphite covered ring during biasing experiments. The supports for the ring are radially flexible to handle the differential thermal growth between the ring and the vessel wall but stiff in the vertical direction to restrain the ring against large disruption forces. The coolant and electrical feeds are designed in a similar manner. 2 refs., 4 figs

  13. Design of DIII-D Advanced Divertor

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.B.; Reis, E.; Schaffer, M.; Thurston, G.

    1989-11-01

    The Advanced Divertor is a modification being designed for the plasma chamber of the DIII-D tokamak in order to optimize the divertor configuration and allow a broader range of experiments to be carried out. The Advanced Divertor will enable two classes of physics experiments to be run in DIII-D: Divertor biasing and Divertor baffling. The Advanced Divertor has two principal components: a toroidally symmetric baffle; and a continuous ring electrode. The tokamak can be run in baffle, bias, or standard DIII-D divertor modes by accurate positioning of the outer divertor strike point through the use of the DIII-D plasma control system. The baffle will contain approximately 50,000 l/s pumping for particle removal in the outer bottom corner of the vacuum vessel. The strike point will be positioned at the entrance aperture for the baffle mode. The aperture geometry is designed to facilitate a large particle influx plus a high probability that backstreaming particles will be reionized and redirected to the aperture. Where the baffling plates meet, gas sealing is required to prevent recycling of neutrals back into the plasma. The electrode is a continuous water-cooled ring, armored with graphite. The ring is electrically isolated from the vessel wall and is biasable to 1 kV and 20 kA. The outer leg of the divertor will be positioned on the graphite covered ring during biasing experiments. The supports for the ring are radially flexible to handle the differential thermal growth between the ring and the vessel wall but stiff in the vertical direction to restrain the ring against large disruption forces. The coolant and electrical feeds are designed in a similar manner. All the feeds are supported from and maintain a 5 kV isolation to the vessel wall. 2 refs., 4 figs

  14. Thermal and structural analysis of the TPX divertor

    International Nuclear Information System (INIS)

    Reis, E.E.; Baxi, C.B.; Chin, E.; Redler, K.M.

    1995-01-01

    The high heat flux on the surfaces of the TPX divertor will require a design in which a carbon-carbon (C-C) tile material is brazed to water cooled copper tubes. Thermal and structural analyses were performed to assist in the design selection of a divertor tile concept and C-C material. The relevancy of finite element analysis (FEA) for evaluating tile design was examined by conducting a literature survey to compare FEA stress results to subsequent brazing and thermal test results. The thermal responses for five tile concepts and four C-C materials were analyzed for a steady-state heat flux of 7.5 MW/m 2 . Elastic-plastic stress analyses were performed to calculate the residual stresses due to brazing C-C tiles to soft copper heat sinks for the various tile designs. Monoblock and archblock divertor tile concepts were analyzed for residual stresses in which elevated temperature creep effects were included with the elastic-plastic behavior of the copper heat sink for an assumed braze cooldown cycle. As a result of these 2D studies, the archblock concept with a 3D fine weave C-C was initially found to be a preferred design for the divertor. A 3D elastic-plastic analysis for brazing of the arch block tile was performed to investigate the singularity effects at the C-C to copper interface in the direction of the tube axis. This analysis showed that the large residual stresses at the tube and tile edge intersection would produce cracks in the C-C and possible delamination along the braze interface. These results, coupled with the difficulties experienced in brazing archblocks for the Tore Supra Limiter, required that other tile designs be considered

  15. An Asdex-type divertor for ITER

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1989-01-01

    An Asdex-type local divertor is proposed for ITER consisting of a copper poloidal field coil adjacent to the plasma. Estimates indicate that the power consumption is acceptable. Advantages would be a much reduced heat load not very sensitive to magnetic perturbations. A disadvantage is the finite lifetime under neutron bombardment that would require periodic replacement of the divertor coils in a reactor, but probably not in ITER because of its limited fluence. Another disadvantage would be poorer blanket coverage unless the divertor coil itself incorporates breeding material. 3 figs

  16. Predicting Behavioral Problems in Craniopharyngioma Survivors after Conformal Radiation Therapy

    Science.gov (United States)

    Dolson, Eugenia P.; Conklin, Heather M.; Li, Chenghong; Xiong, Xiaoping; Merchant, Thomas E.

    2009-01-01

    Background Although radiation therapy is a primary treatment for craniopharyngioma, it can exacerbate existing problems related to the tumor and pre-irradiation management. Survival is often marked by neurologic deficits, panhypopituitarism, diabetes insipidus, cognitive deficiencies and behavioral and social problems. Procedure The Achenbach Child Behavior Checklist (CBCL) was used to evaluate behavioral and social problems during the first five years of follow-up in 27 patients with craniopharyngioma treated with conformal radiation therapy. Results All group averages for the CBCL scales were within the age-typical range at pre-irradiation baseline. Extent of surgical resection was implicated in baseline differences for the Internalizing, Externalizing, Behavior Problem and Social scores. Significant longitudinal changes were found in Internalizing, Externalizing, Behavior Problem and School scores that correlated with tumor and treatment related factors. Conclusions The most common variables implicated in post-irradiation behavioral and social problems were CSF shunting, presence of an Ommaya reservoir, diabetes insipidus, and low pre-irradiation growth hormone levels. PMID:19191345

  17. Effects of impurities and magnetic divertors on high-temperature tokamaks

    International Nuclear Information System (INIS)

    Meade, D.M.; Furth, H.P.; Rutherford, P.H.; Seidl, F.G.P.; Duechs, D.F.

    1974-10-01

    A one-dimensional tokamak plasma transport code has been adapted to include impurity influx, stripping, radiation, and diffusion, as well as the usual processes of hydrogen plasma and heat transport, recycling at the boundary, and multigeneration charge-exchange. Neutral-beam heating, adiabatic compression, and divertor boundary conditions are included as optional features. Illustrative computations are given for present-day and next-generation tokamaks. The problems of impurity control are discussed, and two technical approaches are examined in greater detail: the transient cold-plasma shield, and the poloidal divertor. (auth)

  18. Calculation of the effects of pumping, divertor configuration and fueling on density limit in a tokamak model problem

    International Nuclear Information System (INIS)

    Stacey, W. M.

    2001-01-01

    Several series of model problem calculations have been performed to investigate the predicted effect of pumping, divertor configuration and fueling on the maximum achievable density in diverted tokamaks. Density limitations due to thermal instabilities (confinement degradation and multifaceted axisymmetric radiation from the edge) and to divertor choking are considered. For gas fueling the maximum achievable density is relatively insensitive to pumping (on or off), to the divertor configuration (open or closed), or to the location of the gas injection, although the gas fueling rate required to achieve this maximum achievable density is quite sensitive to these choices. Thermal instabilities are predicted to limit the density at lower values than divertor choking. Higher-density limits are predicted for pellet injection than for gas fueling

  19. Stability, divertors and innovative concepts

    International Nuclear Information System (INIS)

    Mirnov, S.

    2003-01-01

    This paper contains a short resume of the sections on 'Stability, Divertors and Innovative Concepts' presented at the 19th IAEA Fusion Energy Conference. The main conclusions are: (1) the problem of type I ELMs in tokamaks seems to be not so dramatic; (2) it was demonstrated that the working pulse length of large thermonuclear devices can achieve 100 s and more; (3) the problem of tritium retention seems to be not so dramatic now; probable approaches of its solution are visible; (4) active methods of plasma instabilities suppression (NTM, RWM, sawteeth, external MHD) work successfully; (5) new methods of mitigation of the disruption consequences were offered. New technological ideas and new ideas on magnetic confinement were presented. (author)

  20. Divertor cassette movers prototypes for ITER

    International Nuclear Information System (INIS)

    Bogusch, E.; Batz, R.; Bieber, O.; Gottfried, R.; Cerdan, G.

    1998-01-01

    Following competitive tendering, in October 1996 Siemens was contracted by the European Commission to design and supply an assembly of four Divertor Cassette Movers Prototypes including the control and command systems for the movers proper. The assembly consisting of one Cassette Toroidal Mover (CTM), one Radial Mover Tractor (TRC), one Second Cassette Carrier (SCC), and one Radial Cassette Carrier (RCC) represents key components of the Divertor Test Platform at Brasimone, one of the seven large R+D projects for ITER. By detailed design, high-precision manufacturing and testing of these devices, Siemens contributed to the verification of an important task within the European R and D program towards ITER construction. Replacement of the divertor cassettes is a scheduled maintenance operation throughout the life of ITER. The successful fabrication and testing of the Divertor Cassette Movers Prototypes is all important milestone to verify this delicate operation. (authors)

  1. A solid tungsten divertor for ASDEX Upgrade

    International Nuclear Information System (INIS)

    Herrmann, A; Greuner, H; Jaksic, N; Böswirth, B; Maier, H; Neu, R; Vorbrugg, S

    2011-01-01

    The conceptual design of a solid tungsten divertor for ASDEX Upgrade (AUG) is presented. The Div-III design is compatible with the existing divertor structure. It re-establishes the energy and heat receiving capability of a graphite divertor and overcomes the limitations of tungsten coatings. In addition, a solid tungsten divertor allows us to investigate erosion and bulk deuterium retention as well as test castellation and target tilting. The design criteria as well as calculations of forces due to halo and eddy currents are presented. The thermal properties of the proposed sandwich structure are calculated with finite element method models. After extensive testing of a target tile in the high heat flux test facility GLADIS, two solid tungsten tiles were installed in AUG for in-situ testing.

  2. Stochasticity about a poloidal divertor separatrix

    International Nuclear Information System (INIS)

    Skinner, D.A.; Osborne, T.H.; Prager, S.C.; Park, W.

    1986-10-01

    The stochasticization of the magnetic separatrix due to the presence of a helical perturbation in a poloidal divertor tokamak is illustrated by a numerical computation which traces magnetic field lines

  3. Plasma-neutral gas interaction in a tokamak divertor: effects of hydrogen molecules and plasma recombination

    International Nuclear Information System (INIS)

    Krasheninnikov, S.I.; Pigarov, A.Yu.; Soboleva, T.K.; Sigmar, D.J.

    1997-01-01

    We investigate the influence of hydrogen molecules on plasma recombination using a collisional-radiative model for multispecies hydrogen plasmas and tokamak detached divertor parameters. The rate constant found for molecular activated recombination of a plasma can be as high as 2 x 10 -10 cm 3 /s, confirming our pervious estimates. We investigate the effects of hydrogen molecules and plasma recombination on self-consistent plasma-neutral gas interactions in the recycling region of a tokamak divertor. We treat the plasma flow in a fluid approximation retaining the effects of plasma recombination and employing a Knudsen neutral transport model for a 'gas box' divertor geometry. For the model of plasma-neutral interactions we employ we find: (a) molecular activated recombination is a dominant channel of divertor plasma recombination; and (b) plasma recombination is a key element leading to a decrease in the plasma flux onto the target and substantial plasma pressure drop which are the main features of detached divertor regimes. (orig.)

  4. Educational and experiential effects on radiographers' radiation safety behavior

    International Nuclear Information System (INIS)

    Tilson, E.R.

    1982-01-01

    Forty-four radiographers from 11 hospitals in Northern California were observed for radiation safety behaviors in six categories. A multiple regression analysis was performed to determine if there was a significant relationship between the six radiation safety behaviors and the radiographer's age, sex, type of professional training, years since completion of professional training, years of professional practice, time of day, and exposure frequency. The multiple regression analysis showed that there was a significant relationship between use of gonadal shielding and years since completion of professional training, years of professional practice, type of training, and age. The multiple regression analysis also showed that the number of repeated films due to technical error was significantly related to the type of professional training a radiographer received

  5. The dynamical mechanical properties of tungsten under compression at working temperature range of divertors

    International Nuclear Information System (INIS)

    Zhu, C.C.; Song, Y.T.; Peng, X.B.; Wei, Y.P.; Mao, X.; Li, W.X.; Qian, X.Y.

    2016-01-01

    In the divertor structure of ITER and EAST with mono-block module, tungsten plays not only a role of armor material but also a role of structural material, because electromagnetic (EM) impact will be exerted on tungsten components in VDEs or CQ. The EM loads can reach to 100 MN, which would cause high strain rates. In addition, directly exposed to high-temperature plasma, the temperature regime of divertor components is complex. Aiming at studying dynamical response of tungsten divertors under EM loads, an experiment on tungsten employed in EAST divertors was performed using a Kolsky bar system. The testing strain rates and temperatures is derived from actual working conditions, which makes the constitutive equation concluded by using John-Cook model and testing data very accurate and practical. The work would give a guidance to estimate the dynamical response, fatigue life and damage evolution of tungsten divertor components under EM impact loads. - Graphical abstract: From the comparison between the experimental curves and the predicted curves calculated by adopting the corrected m, it is very clear that the new model is of great capability to explain the deformation behavior of the tungsten material under dynamic compression at high temperatures. (EC, PC and PCM refers to experimental curve, predicted curve and predicted curve with a corrected m. Different colors represent different scenarios.). - Highlights: • Test research on dynamic properties of tungsten at working temperature range and strain rate range of divertors. • Constitutive equation descrbing strain hardening, strain rate hardening and temperature softening. • A guidance to estimate dynamical response and damage evolution of tungsten divertor components under impact.

  6. Modelling of island divertor physics and comparison to W7-AS experimental results

    International Nuclear Information System (INIS)

    Feng, Y.; Sardei, F.; Grigull, P.; McCormick, K.; Giannone, L.; Kisslinger, J.; Reiter, D.; Igitkhanov, Y.; Wenzel, U.

    2003-01-01

    Extensive parameter studies have been carried out with the EMC3-EIRENE code. Major code predictions, namely the absence of high recycling prior to detachment, additional momentum losses associated with the specific island divertor geometry and the jump of the radiation at detachment transition have been verified by the W7-AS divertor experiments. Measurements and simulations are compared for high density, high power W7-AS divertor discharges and the physics related to rollover and detachment is discussed in detail. Local comparisons with the W7-AS experiment have been started with a new code version accounting for the real open-island geometry. Specifically, the observed asymmetric power unloading of the target plates at detachment transition could now be reproduced and explained. Agreement with the experiment was also found for the unexpected spatial structure of particle deposition by including classical ExB drifts into the code

  7. Phase behavior and radiation effects in high level waste class

    International Nuclear Information System (INIS)

    Turcotte, R.P.; Roberts, F.P.

    1977-02-01

    Results are presented that demonstrate that detailed and reproducible data can be obtained for complex waste glasses. For the major glass composition examined, thermal treatment was shown to cause formation of several crystalline phases which contribute to an increased leachability. Although not discussed in detail here, Zn 2 SiO 4 formation results in microcracking due to a thermal expansion mismatch with the glass matrix, and SrMoO 4 has a higher leachability than the glass matrix. The temperature dependence describing equilibrium concentrations of these two phases and a qualitative understanding of ingrowth kinetics have been established, hence conditions necessary to eliminate their formation during processing and early storage, are known. Radiation damage effects, when extrapolated to long times, suggest energy storage of approximately 50 cal/gram and either positive or negative density changes occur (depending on the glass composition) in the 1 percent range. No radiation damage-related changes of serious concern have been found for homogeneous glasses by 244 Cm doping experiments now approaching a simulated damage time of approximately 10 3 years (for UO 2 fuel wastes). More work is needed concerning heterogeneous damage which will occur in devitrified glasses. As a final point, the complications with respect to understanding behavior of polyphase systems with respect to either radiation damage or leaching behavior, are self evident. Homogeneous glasses with improved leach resistance, and thermal and radiation stability are clear objectives for future glass development

  8. ARIES-III divertor engineering design

    International Nuclear Information System (INIS)

    Wong, C.P.C.; Schultz, K.R.; Cheng, E.T.; Grotz, S.; Hasan, M.A.; Najmabadi, F.; Sharafat, S.; Herring, J.S.; Valenti, M.; Steiner, D.

    1992-01-01

    This paper reports the engineering design of the ARIES-III double- null divertor. The divertor coolant tubes are made from W-3Re alloy and cooled by subcooled flow boiling of organic coolant. A coating of 4 mm thick tungsten is plasma sprayed onto the divertor surface. This W layer can withstand the thermal deposition of a few disruptions. At a maximum surface heat flux of 5.4 MW/m 2 , a conventional divertor design can be used. The divertor surface is contoured to have a constant heat flux of 5.4 MW/m 2 . The net erosion of the W-surface was found to be negligible at about 0.1 mm/year. After 3 years of operation, the W-3Re alloy ARIES-III divertor can be disposed of as Class A waste. In order to control the prompt dose release at site boundary to less than 200 Rem, isotopic tailoring of the W-alloy will be needed

  9. ARIES-III divertor engineering design

    Energy Technology Data Exchange (ETDEWEB)

    Wong, C.P.C.; Schultz, K.R. [General Atomics, San Diego, CA (United States); Cheng, E.T. [TSI Research, Solana Beach, CA (United States); Grotz, S.; Hasan, M.A.; Najmabadi, F.; Sharafat, S. [California Univ., Los Angeles, CA (United States). Dept. of Mechanical, Aerospace and Nuclear Engineering; Brooks, J.N.; Ehst, D.A.; Sze, D.K. [Argonne National Lab., IL (United States); Herring, J.S. [EG and G Idaho, Inc., Idaho Falls, ID (United States); Valenti, M.; Steiner, D. [Rensselaer Polytechnic Inst., Troy, NY (United States). Plasma Dynamics Lab.

    1992-01-01

    This paper reports the engineering design of the ARIES-III double- null divertor. The divertor coolant tubes are made from W-3Re alloy and cooled by subcooled flow boiling of organic coolant. A coating of 4 mm thick tungsten is plasma sprayed onto the divertor surface. This W layer can withstand the thermal deposition of a few disruptions. At a maximum surface heat flux of 5.4 MW/m{sup 2}, a conventional divertor design can be used. The divertor surface is contoured to have a constant heat flux of 5.4 MW/m{sup 2}. The net erosion of the W-surface was found to be negligible at about 0.1 mm/year. After 3 years of operation, the W-3Re alloy ARIES-III divertor can be disposed of as Class A waste. In order to control the prompt dose release at site boundary to less than 200 Rem, isotopic tailoring of the W-alloy will be needed.

  10. Automated magnetic divertor design for optimal power exhaust

    Energy Technology Data Exchange (ETDEWEB)

    Blommaert, Maarten

    2017-07-01

    The so-called divertor is the standard particle and power exhaust system of nuclear fusion tokamaks. In essence, the magnetic configuration hereby 'diverts' the plasma to a specific divertor structure. The design of this divertor is still a key issue to be resolved to evolve from experimental fusion tokamaks to commercial power plants. The focus of this dissertation is on one particular design requirement: avoiding excessive heat loads on the divertor structure. The divertor design process is assisted by plasma edge transport codes that simulate the plasma and neutral particle transport in the edge of the reactor. These codes are computationally extremely demanding, not in the least due to the complex collisional processes between plasma and neutrals that lead to strong radiation sinks and macroscopic heat convection near the vessel walls. One way of improving the heat exhaust is by modifying the magnetic confinement that governs the plasma flow. In this dissertation, automated design of the magnetic configuration is pursued using adjoint based optimization methods. A simple and fast perturbation model is used to compute the magnetic field in the vacuum vessel. A stable optimal design method of the nested type is then elaborated that strictly accounts for several nonlinear design constraints and code limitations. Using appropriate cost function definitions, the heat is spread more uniformly over the high-heat load plasma-facing components in a practical design example. Furthermore, practical in-parts adjoint sensitivity calculations are presented that provide a way to an efficient optimization procedure. Results are elaborated for a fictituous JET (Joint European Torus) case. The heat load is strongly reduced by exploiting an expansion of the magnetic flux towards the solid divertor structure. Subsequently, shortcomings of the perturbation model for magnetic field calculations are discussed in comparison to a free boundary equilibrium (FBE) simulation

  11. Automated magnetic divertor design for optimal power exhaust

    International Nuclear Information System (INIS)

    Blommaert, Maarten

    2017-01-01

    The so-called divertor is the standard particle and power exhaust system of nuclear fusion tokamaks. In essence, the magnetic configuration hereby 'diverts' the plasma to a specific divertor structure. The design of this divertor is still a key issue to be resolved to evolve from experimental fusion tokamaks to commercial power plants. The focus of this dissertation is on one particular design requirement: avoiding excessive heat loads on the divertor structure. The divertor design process is assisted by plasma edge transport codes that simulate the plasma and neutral particle transport in the edge of the reactor. These codes are computationally extremely demanding, not in the least due to the complex collisional processes between plasma and neutrals that lead to strong radiation sinks and macroscopic heat convection near the vessel walls. One way of improving the heat exhaust is by modifying the magnetic confinement that governs the plasma flow. In this dissertation, automated design of the magnetic configuration is pursued using adjoint based optimization methods. A simple and fast perturbation model is used to compute the magnetic field in the vacuum vessel. A stable optimal design method of the nested type is then elaborated that strictly accounts for several nonlinear design constraints and code limitations. Using appropriate cost function definitions, the heat is spread more uniformly over the high-heat load plasma-facing components in a practical design example. Furthermore, practical in-parts adjoint sensitivity calculations are presented that provide a way to an efficient optimization procedure. Results are elaborated for a fictituous JET (Joint European Torus) case. The heat load is strongly reduced by exploiting an expansion of the magnetic flux towards the solid divertor structure. Subsequently, shortcomings of the perturbation model for magnetic field calculations are discussed in comparison to a free boundary equilibrium (FBE) simulation. These flaws

  12. Divertor Design and Physics Issues of Huge Power Handling for SlimCS Demo Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, N.; Hoshino, K.; Tobita, K.; Someya, Y.; Utoh, H.; Nakamura, M., E-mail: asakura.nobuyuki@jaea.go.jp [Japan Atomic Energy Agency, Rokkasho (Japan); Shimizu, K. [Japan Atomic Energy Agency, Naka (Japan); Takizuka, T. [Osaka University, Osaka (Japan)

    2012-09-15

    Full text: Power exhaust scenario for a 3 GW class fusion reactor with the ITER-size plasma has been developed with enhancing the radiation loss from seeding impurity. Transport of plasma, impurity and neutrals was simulated self-consistently, for the first time, under the Demo divertor condition using an integrated divertor simulation code SONIC. The total heat load, q{sub target}, was evaluated including radiation power load and neutral load, in addition to the plasma heat load. It was found that heat and particle diffusion coefficients significantly affect the plasma detachment. For the case of increasing the coefficients by the factor of two, peak q{sub target} is reduced from 18 MW/m{sup 2} to below the engineering design level of 10 MW/m{sup 2}, while the characteristic width of the heat flux at the midplane SOL increases slightly from 2.2 to 2.7 mm. It was also found that that enhancement of the local {chi} and D at the outer SOL affects a reduction in the peak q{sub target} near the separatrix. Effects of the divertor geometry such as the divertor leg were investigated. Outer divertor leg length was extended to 2.7 m, while the magnetic flux expansion at the target is reduced to a half compared to the reference case of 1.8 m. Large radiation volume is shifted further upstream from the target due to a reduction in T{sub e}. The peak q{sub target} decreases to 10 MW/m{sup 2} due to reduction in both the plasma heat load and the radiation power load. (author)

  13. Analysis of noble gas recycling at a fusion plasma divertor

    International Nuclear Information System (INIS)

    Brooks, J.N.

    1996-01-01

    Near-surface recycling of neon and argon atoms and ions at a divertor has been studied using impurity transport and surface interaction codes. A fixed background deuterium endash tritium plasma model is used corresponding to the International Thermonuclear Experimental Reactor (ITER) [ITER EDA Agreement and Protocol 2, ITER EDA Documentation Series No. 5 (International Atomic Energy Agency, Vienna, 1994)] radiative plasma conditions (T e ≤10 eV). The noble gas transport depends critically on the divertor surface material. For low-Z materials (Be and C) both neon and argon recycle many (e.g., ∼100) times before leaving the near-surface region. This is also true for an argon on tungsten combination. For neon on tungsten, however, there is low recycling. These variations are due to differences in particle and energy reflection coefficients, mass, and ionization rates. In some cases a high flux of recycling atoms is ionized within the magnetic sheath and this can change local sheath parameters. Due to inhibited backflow, high recycling, and possibly high sputtering, noble gas seeding (for purposes of enhancing radiation) may be incompatible with Be or C surfaces, for fusion reactor conditions. On the other hand, neon use appears compatible with tungsten. copyright 1996 American Institute of Physics

  14. Divertor power and particle fluxes between and during type-I ELMs in the ASDEX Upgrade

    Science.gov (United States)

    Kallenbach, A.; Dux, R.; Eich, T.; Fischer, R.; Giannone, L.; Harhausen, J.; Herrmann, A.; Müller, H. W.; Pautasso, G.; Wischmeier, M.; ASDEX Upgrade Team

    2008-08-01

    Particle, electric charge and power fluxes for type-I ELMy H-modes are measured in the divertor of the ASDEX Upgrade tokamak by triple Langmuir probes, shunts, infrared (IR) thermography and spectroscopy. The discharges are in the medium to high density range, resulting in predominantly convective edge localized modes (ELMs) with moderate fractional stored energy losses of 2% or below. Time resolved data over ELM cycles are obtained by coherent averaging of typically one hundred similar ELMs, spatial profiles from the flush-mounted Langmuir probes are obtained by strike point sweeps. The application of simple physics models is used to compare different diagnostics and to make consistency checks, e.g. the standard sheath model applied to the Langmuir probes yields power fluxes which are compared with the thermographic measurements. In between ELMs, Langmuir probe and thermography power loads appear consistent in the outer divertor, taking into account additional load due to radiation and charge exchange neutrals measured by thermography. The inner divertor is completely detached and no significant power flow by charged particles is measured. During ELMs, quite similar power flux profiles are found in the outer divertor by thermography and probes, albeit larger uncertainties in Langmuir probe evaluation during ELMs have to be taken into account. In the inner divertor, ELM power fluxes from thermography are a factor 10 larger than those derived from probes using the standard sheath model. This deviation is too large to be caused by deficiencies of probe analysis. The total ELM energy deposition from IR is about a factor 2 higher in the inner divertor compared with the outer divertor. Spectroscopic measurements suggest a quite moderate contribution of radiation to the target power load. Shunt measurements reveal a significant positive charge flow into the inner target during ELMs. The net number of elementary charges correlates well with the total core particle loss

  15. Verification of the behavior of insulating materials under ionizing radiation

    International Nuclear Information System (INIS)

    Reis, Joao C. Marques dos; Rezende, Aurimar de P.; Menzel, Silvio C.

    2009-01-01

    To analyze the behavior of specifics electrical insulating materials and components under ionizing radiation, a test program was developed to verify the overall effects of general electrical equipment under high radiation fields conditions. The main objective is for maintenance purposes, in the substitution of electrical components installed in the reactor building of the Angra 1 nuclear power plant. Knowing the characteristics of electrical insulating materials available in the country and determining by tests their ability to withstand the ionizing radiation effects, is feasible to implement specific maintenance services of electrical equipment, maintaining the same level of quality and safety for the specified application. This procedure reduces the time and also costs of maintenance services, in comparison with materials acquired or services performed abroad. The isolating materials and components of electrical equipment should be specified, manufactured and qualified to withstand aggressive environmental conditions in the reactor building during the normal operation and postulated accident. Additional tests should be conducted to verify the conditions of the aged material by ionizing radiation. Examples of additional tests: dielectric strength, tensile strength and elongation and impact resistance. (author)

  16. First results from the dynamic ergodic divertor at TEXTOR

    International Nuclear Information System (INIS)

    Lehnen, M.; Abdullaev, S.S.; Biel, W.; Brezinsek, S.; Finken, K.H.; Harting, D.; Hellermann, M. von; Jakubowski, M.; Jaspers, R.; Kobayashi, M.; Koslowski, H.R.; Kraemer-Flecken, A.; Matsunaga, G.; Pospieszczyk, A.; Reiter, D.; Van Rompuy, T.; Samm, U.; Schmitz, O.; Sergienko, G.; Unterberg, B.; Wolf, R.; Zimmermann, O.

    2005-01-01

    Experimental results from the dynamic ergodic divertor (DED) at TEXTOR are given, describing the complex structure of the edge plasma and the properties of the divertor as well as its influence on the plasma rotation

  17. Optimization for steady-state and hybrid operations of ITER by using scaling models of divertor heat load

    International Nuclear Information System (INIS)

    Murakami, Yoshiki; Itami, Kiyoshi; Sugihara, Masayoshi; Fujieda, Hirobumi.

    1992-09-01

    Steady-state and hybrid mode operations of ITER are investigated by 0-D power balance calculations assuming no radiation and charge-exchange cooling in divertor region. Operation points are optimized with respect to divertor heat load which must be reduced to the level of ignition mode (∼5 MW/m 2 ). Dependence of the divertor heat load on the variety of the models, i.e., constant-χ model, Bohm-type-χ model and JT-60U empirical scaling model, is also discussed. The divertor heat load increases linearly with the fusion power (P FUS ) in all models. The possible highest fusion power much differs for each model with an allowable divertor heat load. The heat load evaluated by constant-χ model is, for example, about 1.8 times larger than that by Bohm-type-χ model at P FUS = 750 MW. Effect of reduction of the helium accumulation, improvements of the confinement capability and the current-drive efficiency are also investigated aiming at lowering the divertor heat load. It is found that NBI power should be larger than about 60 MW to obtain a burn time longer than 2000 s. The optimized operation point, where the minimum divertor heat load is achieved, does not depend on the model and is the point with the minimum-P FUS and the maximum-P NBI . When P FUS = 690 MW and P NBI = 110 MW, the divertor heat load can be reduced to the level of ignition mode without impurity seeding if H = 2.2 is achieved. Controllability of the current-profile is also discussed. (J.P.N.)

  18. Geometrical properties of a 'snowflake' divertor

    International Nuclear Information System (INIS)

    Ryutov, D. D.

    2007-01-01

    Using a simple set of poloidal field coils, one can reach the situation in which the null of the poloidal magnetic field in the divertor region is of second order, not of first order as in the usual X-point divertor. Then, the separatrix in the vicinity of the null point splits the poloidal plane not into four sectors, but into six sectors, making the whole structure look like a snowflake (hence the name). This arrangement allows one to spread the heat load over a much broader area than in the case of a standard divertor. A disadvantage of this configuration is that it is topologically unstable, and, with the current in the plasma varying with time, it would switch either to the standard X-point mode, or to the mode with two X-points close to each other. To avoid this problem, it is suggested to have a current in the divertor coils that is roughly 5% higher than in an ''optimum'' regime (the one in which a snowflake separatrix is formed). In this mode, the configuration becomes stable and can be controlled by varying the current in the divertor coils in concert with the plasma current; on the other hand, a strong flaring of the scrape-off layer still remains in force. Geometrical properties of this configuration are analyzed. Potential advantages and disadvantages of this scheme are discussed

  19. EU R and D on divertor components

    International Nuclear Information System (INIS)

    Merola, M.; Daenner, W.; Pick, M.

    2005-01-01

    Since the last SOFT conference held in Helsinki in 2002, substantial progress has been made in the EU R and D on the divertor components. A number of activities have been completed and new ones have been launched. The present paper gives an update of the works carried out by the EU Participating Team in support of the development of the divertor, which is one of the most challenging components of the next-step ITER machine. The following topics are covered: (1) the further development and consolidation of suitable technologies for the production of high heat-flux components, which culminated with the successful manufacturing and testing of a full-scale vertical target prototype; (2) the completion of the post-irradiation testing of divertor mock-ups and samples; (3) the preparation for the hydraulic and assembly tests of a complete set of full-scale divertor components; (4) the on-going R and D on the definition of workable acceptance criteria for the procurement of ITER high heat-flux components; (5) the activities in support of the divertor design

  20. Design of a diagnostic residual gas analyzer for the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Klepper, C.C., E-mail: kleppercc@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6169 (United States); Biewer, T.M.; Graves, V.B. [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6169 (United States); Andrew, P. [ITER Organisation, Route de Vinon-sur-Verdon, 13067 St. Paul-lez-Durance (France); Lukens, P.C. [US ITER Project Office, 1055 Commerce Park Dr #1, Oak Ridge, TN 37830 (United States); Marcus, C. [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6169 (United States); Shimada, M., E-mail: shimada.michiya@jaea.go.jp [ITER Organisation, Route de Vinon-sur-Verdon, 13067 St. Paul-lez-Durance (France); Hughes, S.; Boussier, B. [ITER Organisation, Route de Vinon-sur-Verdon, 13067 St. Paul-lez-Durance (France); Johnson, D.W. [US ITER Diagnostics Office, Princeton Plasma Physics Laboratory, Princeton, NJ 08540 (United States); Gardner, W.L. [US ITER Project Office, 1055 Commerce Park Dr #1, Oak Ridge, TN 37830 (United States); Hillis, D.L. [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6169 (United States); Vayakis, G.; Walsh, M. [ITER Organisation, Route de Vinon-sur-Verdon, 13067 St. Paul-lez-Durance (France)

    2015-10-15

    Highlights: • The divertor DRGA for ITER will measure neutral gas composition in the pumping ducts during plasma. • System must respond in timescales relevant to compositional changes in the divertor plasma. • It is shown that times can vary from 1 to 6 s for fuel (H2, D2, T2) up to 50 s for He (fusion reaction ash). • It is shown that present design delivers ∼ 1 s response even via an 8m long sampling pipe sampling. • Response time validated with VacTran{sup ®} over anticipated the 0.1–10 Pa pressure range in the ducts. - Abstract: One of the ITER diagnostics having reached an advanced design stage is a diagnostic RGA for the divertor, i.e. residual gas analysis system for the ITER divertor, which is intended to sample the divertor pumping duct region during the plasma pulse and to have a response time compatible with plasma particle and impurity lifetimes in the divertor region. Main emphasis is placed on helium (He) concentration in the ducts, as well as the relative concentration between the hydrogen isotopes (mainly in the form of diatomic molecules of H, D, and T). Measurement of the concentration of radiative gases, such as neon (Ne) and nitrogen (N{sub 2}), is also intended. Numerical modeling of the gas flow from the sampled region to the cluster of analysis sensors, through a long (∼8 m long, ∼110 mm diameter) sampling pipe originating from a pressure reducing orifice, confirm that the desired response time (∼1 s for He or D{sub 2}) is achieved with the present design.

  1. Ionizing radiation: effects upon acquisition and performance of behavior

    International Nuclear Information System (INIS)

    Vasconcelos, Laercia Abreu

    1999-03-01

    The present study, using rats as subjects, attempted to assess the effects of multiple exposures to gamma radiation upon behavior in two procedures of a multiple schedule of repeated acquisition and performance. With an experimental chamber containing three levers displaced horizontally, left (l), center (c) and right (r), different levels of complexity were programmed for procedures A and B. In both procedures a new sequence of three responses was programmed for each session (lcr, lrc, clr, crl, rlc) for the acquisition component, whereas for the performance component the same sequence was maintained throughout the sessions. The completion of three sequences (nine responses) was followed by reinforcement and incorrect responses were followed by time-out without correction procedures. In procedure A the sequences consisted of one response in each lever (for example, crl→crl→crl→reinforcement) while in procedure B a sequence consisted of three response in the same lever, with the following three responses having to occur in a different lever (for example, ccc→rrr→lll→reinforcement). Six subjects were trained in each procedure. Base line data showed, by means of error percentage, that procedure B regardless of being more complex represented a lower difficulty level than procedure A: subjects in procedure B displayed, in general, a lower number of errors per session. After training in these procedures of repeated acquisition and performance, the subjects were exposed to doses of ionizing radiation of 3.0, 4.5, 6.0 and 8.0 Gy, with an interval of 45 days between exposures. With measurements of response rate and obtained reinforcers, the data showed a dose-response relation, with higher doses producing lower rates of responses and reinforcers. Percentage of errors was higher after doses of 6.0 and 8.0 Gy in the performance component, while changes in error patterns occurred in the acquisition component. The effects of radiation was more evident and orderly

  2. Development of integrated SOL/Divertor code and simulation study of the JT-60U/JT-60SA tokamaks

    International Nuclear Information System (INIS)

    Kawashima, H.; Shimizu, K.; Takizuka, T.

    2007-01-01

    To predict the particle and heat controllability in the divertor of tokamak reactors such as ITER and to optimize the divertor design, comprehensive simulations by integrated modelling with taking in various physical processes are indispensable. For the design study of ITER divertor, the modelling codes such as B2, UEDGE and EDGE2D have been developed, and their results have contributed to the evolution of the divertor concept. In Japan Atomic Energy Agency (JAEA), SOL/divertor codes have also been developed for the interpretation and the prediction on behaviours of plasmas, neutrals and impurities in the SOL/divertor regions. The code development is originally carried out since physics models can be verified quickly and flexibly under the circumstance of close collaboration with JT-60 team. Figure 1 shows our code system, which consists of the 2 dimensional fluid code SOLDOR, the neutral Monte Carlo (MC) code NEUT2D, and the impurity MC code IMPMC. The particle simulation code PARASOL has also been developed in order to establish the physics modelling used in fluid simulations. Integration of SOLDOR, NEUT2D and IMPMC, called the '' SONIC '' code, is being carried out to simulate self-consistently the SOL/divertor plasmas in present tokamaks and in future devices. Combination of the SOLDOR and NEUT2D was completed, which has the features such as 1) high-resolution oscillation-free scheme in solving fluid equations, 2) neutral transport calculation under the fine meshes, 3) success in reduction of MC noise, 4) optimization on the massive parallel computer, etc. The simulation reproduces the X-point MARFE in the JT-60U experiment. It is found that the chemically sputtered carbon at the dome causes the radiation peaking near the X-point. The performance of divertor pumping in JT-60U is evaluated from the particle balances. We also present the divertor designing of JT-60SA, which is the modification program of JT-60U to establish high beta steady-state operation. To

  3. Analysis of particle transport in a gas target divertor

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsu, Shigeki; Tanaka, Satoru [Tokyo Univ. (Japan). Faculty of Engineering

    1996-10-01

    2-dimensional modelling of divertor plasma was performed with three types of the divertor geometry configuration. Pumping is effective to reduce neutral recycling to core region in the configuration without baffle. In baffle configuration, a good shielding of neutrals in the divertor region can be achieved. The dome configuration reduces plasma density near the null region and flow shear near the separatrix. (author)

  4. Experimental studies of the snowflake divertor in TCV

    NARCIS (Netherlands)

    Labit, B.; Canal, G. P.; Christen, N.; Duval, B. P.; Lipschultz, B.; Lunt, T.; Nespoli, F.; Reimerdes, H.; Sheikh, U.; Theiler, C.; Tsui, C. K.; Verhaegh, K.; Vijvers, W. A. J.

    2017-01-01

    To address the risk that, in a fusion reactor, the conventional single-null divertor (SND) configuration may not be able to handle the power exhaust, alternative divertor configurations, such as the Snowflake divertor (SFD), are investigated in TCV. The expected benefits of the SFD-minus in terms of

  5. Neutral particle retention in the JET MK I divertor

    International Nuclear Information System (INIS)

    Ehrenberg, J.K.; Campbell, D.J.; Harbour, P.J.; Horton, L.D.; Loarte, A.; McCormick, G.K.; Monk, R.D.; Saibene, G.R.; Simonini, R.; Taroni, A.; Stamp, M.F.

    1997-01-01

    Retention of neutral deuterium and nitrogen in the JET MK I divertor has been investigated. Results show that ohmic plasma detachment reduces deuterium retention, that the magnetic divertor configuration has some influence on the achievable deuterium retention, and that nitrogen in nitrogen-seeded steady state detached H-mode discharges accumulates in the divertor. (orig.)

  6. Thermal effects of runaway electrons in an armoured divertor

    International Nuclear Information System (INIS)

    Stad, R.C.L. van der.

    1993-12-01

    This report describes the results of a numerical thermal analysis of the heat deposition of runaway electrons accompanying plasma disruptions in a armoured divertor. The divertor concepts studied are carbon on molybdenum and beryllium on copper. The conclusion is that the runaway electrons can cause melting of the armour as well as melting of the structure and can damage the divertor severely. (orig.)

  7. Liquid metal cooled divertor for ARIES

    International Nuclear Information System (INIS)

    Muraviev, E.

    1995-01-01

    A liquid metal, Ga-cooled divertor design was completed for the double null ARIES-II divertor design. The design analysis indicated a surface heat flux removal capability of up to 15 MW/m 2 , and its relative easy maintenance. Design issues of configuration, thermal hydraulics, thermal stresses, liquid metal loop and safety effects were evaluated. For coolant flow control, it was found that it is necessary to use some part of the blanket cooling ducts for the draining of liquid metal from the top divertor. In order to minimize the inventory of Ga, it was recommended that the liquid metal loop equipment should be located as close to the torus as possible. More detailed analysis of transient conditions especially under accident conditions was identified as an issue that will need to be addressed

  8. Constrained ripple optimization of Tokamak bundle divertors

    International Nuclear Information System (INIS)

    Hively, L.M.; Rome, J.A.; Lynch, V.E.; Lyon, J.F.; Fowler, R.H.; Peng, Y-K.M.; Dory, R.A.

    1983-02-01

    Magnetic field ripple from a tokamak bundle divertor is localized to a small toroidal sector and must be treated differently from the usual (distributed) toroidal field (TF) coil ripple. Generally, in a tokamak with an unoptimized divertor design, all of the banana-trapped fast ions are quickly lost due to banana drift diffusion or to trapping between the 1/R variation in absolute value vector B ω B and local field maxima due to the divertor. A computer code has been written to optimize automatically on-axis ripple subject to these constraints, while varying up to nine design parameters. Optimum configurations have low on-axis ripple ( 0 ) are lost. However, because finite-sized TF coils have not been used in this study, the flux bundle is not expanded

  9. Design integration of liquid surface divertors

    International Nuclear Information System (INIS)

    Nygren, R.E.; Cowgill, D.F.; Ulrickson, M.A.; Nelson, B.E.; Fogarty, P.J.; Rognlien, T.D.; Rensink, M.E.; Hassanein, A.; Smolentsev, S.S.; Kotschenreuther, M.

    2004-01-01

    The US Enabling Technology Program in fusion is investigating the use of free flowing liquid surfaces facing the plasma. We have been studying the issues in integrating a liquid surface divertor into a configuration based upon an advanced tokamak, specifically the ARIES-RS configuration. The simplest form of such a divertor is to extend the flow of the liquid first wall into the divertor and thereby avoid introducing additional fluid streams. In this case, one can modify the flow above the divertor to enhance thermal mixing. For divertors with flowing liquid metals (or other electrically conductive fluids) MHD (magneto-hydrodynamics) effects are a major concern and can produce forces that redirect flow and suppress turbulence. An evaluation of Flibe (a molten salt) as a working fluid was done to assess a case in which the MHD forces could be largely neglected. Initial studies indicate that, for a tokamak with high power density, an integrated Flibe first wall and divertor does not seem workable. We have continued work with molten salts and replaced Flibe with Flinabe, a mixture of lithium, sodium and beryllium fluorides, that has some potential because of its lower melting temperature. Sn and Sn-Li have also been considered, and the initial evaluations on heat removal with minimal plasma contamination show promise, although the complicated 3D MHD flows cannot yet be fully modeled. Particle pumping in these design concepts is accomplished by conventional means (ports and pumps). However, trapping of hydrogen in these flowing liquids seems plausible and novel concepts for entrapping helium are also being studied

  10. Towards the procurement of the ITER divertor

    International Nuclear Information System (INIS)

    Merola, M.; Tivey, R.; Martin, A.; Pick, M.

    2006-01-01

    The procurement of the ITER divertor is planned to start in 2009. On the basis of the present common understanding of the sharing of the ITER components, the Japanese Participating Team (JAPT) will supply the outer vertical target, the Russian Federation (RF) PT the dome liner and will perform the high heat flux testing, the EU PT will supply the inner vertical targets and the cassette bodies, including final assembly of the divertor plasma-facing components (PFCs). The manufacturing of the PFCs of the ITER divertor represents a challenging endeavor due to the high technologies which are involved, and due to the unprecedented series production. To mitigate the associated risks, special arrangements need to be put in place prior to and during procurement to ensure quality and to keep to the time schedule. Before procurement can start, an ITER review of the qualification and production capability of each candidate PT is planned. Well in advance of the assumed start of the procurement, each PT which would like to contribute to the divertor PFC procurement, should first demonstrate its technical qualification to carry out the procurement with the required quality, and in an efficient and timely manner. Appropriate precautions, like subdivision of the procurement into stages, are also to be adopted during the procurement phase to mitigate the consequences of possible unexpected manufacturing problems. In preparation for writing the procurement specification for the vertical targets, the topic of setting acceptance criteria is also being addressed. This activity has the objective of defining workable acceptance criteria for the PFC armour joints. A complete set of analyses is also in progress to assess the latest design modifications against the design requirements. This task includes neutronic, shielding, thermo-mechanical and electromagnetic analyses. More than half of the ITER plasma parameters that must be measured and the related diagnostics are located in the

  11. Local island divertor experiments on LHD

    International Nuclear Information System (INIS)

    Morisaki, T.; Masuzaki, S.; Komori, A.; Ohyabu, N.; Kobayashi, M.; Feng, Y.; Sardei, F.; Narihara, K.; Tanaka, K.; Ida, K.; Peterson, B.J.; Yoshinuma, M.; Ashikawa, N.; Emoto, M.; Funaba, H.; Goto, M.; Ikeda, K.; Inagaki, S.; Kaneko, O.; Kawahata, K.; Kubo, S.; Miyazawa, J.; Morita, S.; Nagaoka, K.; Nagayama, Y.; Nakanishi, H.; Ohkubo, K.; Oka, Y.; Osakabe, M.; Shimozuma, T.; Shoji, M.; Takeiri, Y.; Sakakibara, S.; Sakamoto, R.; Sato, K.; Toi, K.; Tsumori, K.; Watababe, K.Y.; Yamada, H.; Yamada, I.; Yoshimura, Y.; Motojima, O.

    2005-01-01

    A local island divertor (LID) experiment has begun on LHD, with the aims of controlling edge recycling and improving the plasma confinement. The fundamental divertor functions of the LID have been demonstrated in the recent experiments. From the particle flux profile measurements on the LID head it was found that the particles diffusing out from the core region are well guided along the island separatrix to the LID head. Owing to the closed configuration around the LID head, evidence of the high efficient pumping was observed, together with a strong capacity to screen impurities. The first results of edge modeling using the EMC3-EIRENE code are also presented

  12. Control of divertor configuration in JT-60

    International Nuclear Information System (INIS)

    Yoshino, R.; Kukuchi, M.; Ninomiya, H.; Yoshida, H.; Tsuji, S.; Hosogane, N.; Seki, S.

    1985-01-01

    The control algorithm of JT-60 divertor configuration is presented. JT-60 has five types of poloidal magnetic field coil with each power supply in order to regulate the control objectives mentioned above. However, if one controls each objective by each coil current independently, there must inevitably occur large interaction between control objectives. Because the relation between control objectives and coil currents is complicated. This situation may be the same with a fusion reactor device. For making it possible to control each objective independently without causing large interaction, the authors adopt the noninteracting control algorithm. Hence, this report demonstrates the availability of this method to the control of JT-60 divertor configuration

  13. Safety characteristics of the monolithic CFC divertor

    International Nuclear Information System (INIS)

    Zucchetti, M.; Merola, M.; Matera, R.

    1994-01-01

    The main distinguishing feature of the monolithic CFC divertor is the use of a single material, a carbon fibre reinforced carbon, for the protective armour, the heat sink and the cooling channels. This removes joint interface problems which are one of the most important concerns related to the reference solutions of the ITER CDA divertor. An activation analysis of the different coolant options for this concept is presented. It turns out that neither short-term nor long-term activation are a concern for any coolants investigated. Therefore the proposed concept proves to be attractive from a safety stand-point also. ((orig.))

  14. Safety characteristics of the monolithic CFC divertor

    Science.gov (United States)

    Zucchetti, M.; Merola, M.; Matera, R.

    1994-09-01

    The main distinguishing feature of the monolithic CFC divertor is the use of a single material, a carbon fibre reinforced carbon, for the protective armour, the heat sink and the cooling channels. This removes joint interface problems which are one of the most important concerns related to the reference solutions of the ITER CDA divertor. An activation analysis of the different coolant options for this concept is presented. It turns out that neither short-term nor long-term activation are a concern for any coolants investigated. Therefore the proposed concept proves to be attractive from a safety stand-point also.

  15. Initial results from the Tokapole-II poloidal divertor device

    International Nuclear Information System (INIS)

    Biddle, A.P.; Dexter, R.N.; Groebner, R.J.; Holly, D.J.; Lipschultz, B.; Phillips, M.W.; Prager, S.C.; Sprott, J.C.

    1979-01-01

    The latest in a series of internal-ring devices, called Tokapole II, has recently begun operation at the University of Wisconsin. Its purpose is to permit the study of the production and confinement of hot, dense plasmas in either a toroidal octupole (with or without toroidal field) or a tokamak with a four-node poloidal divertor. The characteristics of the device and the results of its initial operation are described here. Quantitative measurements of impurity concentration and radiated power have been made. Poloidal divertor equilibria of square and dee shapes have been produced, and an axisymmetric instability has been observed with the inverse dee. Electron cyclotron resonance heating is used to initiate the breakdown near the axis and to control the initial influx of impurities. A 2-MW RF source at the second harmonic of the ion cyclotron frequency is available and has been used to double the ion temperature when operated at low power with an unoptimized antenna. Initial results of operation as a pure octupole with poloidal Ohmic heating suggest a tokamak-like scaling of density (n proportional to Bsub(p)) and confinement time (tau proportional to n). (author)

  16. Innovative Divertor Development to Solve the Plasma Heat-Flux Problem

    International Nuclear Information System (INIS)

    Rognlien, T.; Ryutov, D.; Makowski, M.; Soukhanovskii, V.; Umansky, M.; Cohen, R.; Hill, D.; Joseph, I.

    2009-01-01

    Large, localized plasma heat exhaust continues to be one of the critical problems for the development of tokamak fusion reactors. Excessive heat flux erodes and possibly melts plasma-facing materials, thereby dramatically shortening their lifetime and increasing the impurity contamination of the core plasma. A detailed assessment by the ITER team for their divertor has revealed substantial limitations on the operational space imposed by the divertor performance. For a fusion reactor, the problem becomes worse in that the divertor must accommodate 20% of the total fusion power (less any broadly radiated loss), while not allowing excess buildup of tritium in the walls nor excessive impurity production. This is an extremely challenging set of problems that must be solved for fusion to succeed as a power source; it deserves a substantial research investment. Material heat-flux constraints: Results from present-day tokamaks show that there are two major limitations of peak plasma heat exhaust. The first is the continuous flow of power to the divertor plates and nearby surfaces that, for present technology, is limited to 10-20 MW/m 2 . The second is the transient peak heat-flux that can be tolerated in a short time, τ m , before substantial ablation and melting of the surface occurs; such common large transient events are Edge Localized Mode (ELMs) and disruptions. The material limits imposed by these events give a peak energy/τ m 1/2 parameter of ∼ 40 MJ/m 2 s 1/2 (1). Both the continuous and transient limits can be approached by input powers in the largest present-day devices, and future devices are expected to substantially exceed the limits unless a solution can be found. Since the early 90's LLNL has developed the analytic and computational foundation for analyzing divertor plasmas, and also suggested and studied a number of solid and liquid material concepts for improving divertor/wall performance, with the most recent being the Snowflake divertor concept (2

  17. Possible divertor solutions for a fusion reactor. Pt. I. Physical aspects based on present day divertor operation

    International Nuclear Information System (INIS)

    Kallenbach, A.; Bosch, H.-S.; De Pena Hempel, S.; Dux, R.; Kaufmann, M.; Mertens, V.; Neuhauser, J.; Suttrop, W.; Zohm, H.

    1997-01-01

    For pt.II see ibid., p.109-117 (1997). With an anticipated power flux across the separatrix of up to 300 MW of an ITER-like fusion reactor, conventional measures of power spread lead to a peak power load at the target plates in the order of 30 MW m -2 , far beyond the technically feasible limit for stationary operation. Radiative cooling by seed impurities appears to be the most promising plasma-physical option to reduce the target power load, but extrapolations of present experiments predict an only marginally tolerable increase of the plasma effective charge Z eff . Key points will be the achievement of very high electron densities, leading to more effective radiative cooling by δP rad /δZ eff ∝n e 2 while keeping the edge temperature within its optimum range. This range is bounded from below by the H→L mode temperature threshold due to confinement requirements, whereas the upper boundary is given by the ideal ballooning stability limit which is connected to type-I ELM activity which may cause non-tolerable divertor heat loads. The completely detached H-mode (CDH) in ASDEX Upgrade demonstrates radiative H-mode operation within this operational range exhibiting high-frequent type-III ELMs and target power load in the order of 10% of the heating power. At present, open questions on high density reactor operation are related to radiative instabilities as well as edge transport enhancement and H-mode impairment observed in several tokamaks under high density conditions. Measures to overcome these detrimental effects will be investigated with improved divertor concepts in the near future. The possible problems connected to high density reactor operation can be relaxed, if the design of plasma facing components with higher heat flux endurance is successful. (orig.)

  18. Parametric analyses of DEMO Divertor using two dimensional transient thermal hydraulic modelling

    Science.gov (United States)

    Domalapally, Phani; Di Caro, Marco

    2018-05-01

    Among the options considered for cooling of the Plasma facing components of the DEMO reactor, water cooling is a conservative option because of its high heat removal capability. In this work a two-dimensional transient thermal hydraulic code is developed to support the design of the divertor for the projected DEMO reactor with water as a coolant. The mathematical model accounts for transient 2D heat conduction in the divertor section. Temperature-dependent properties are used for more accurate analysis. Correlations for single phase flow forced convection, partially developed subcooled nucleate boiling, fully developed subcooled nucleate boiling and film boiling are used to calculate the heat transfer coefficients on the channel side considering the swirl flow, wherein different correlations found in the literature are compared against each other. Correlation for the Critical Heat Flux is used to estimate its limit for a given flow conditions. This paper then investigates the results of the parametric analysis performed, whereby flow velocity, diameter of the coolant channel, thickness of the coolant pipe, thickness of the armor material, inlet temperature and operating pressure affect the behavior of the divertor under steady or transient heat fluxes. This code will help in understanding the basic parameterś effect on the behavior of the divertor, to achieve a better design from a thermal hydraulic point of view.

  19. Small angle slot divertor concept for long pulse advanced tokamaks

    Science.gov (United States)

    Guo, H. Y.; Sang, C. F.; Stangeby, P. C.; Lao, L. L.; Taylor, T. S.; Thomas, D. M.

    2017-04-01

    SOLPS-EIRENE edge code analysis shows that a gas-tight slot divertor geometry with a small-angle (glancing-incidence) target, named the small angle slot (SAS) divertor, can achieve cold, dissipative/detached divertor conditions at relatively low values of plasma density at the outside midplane separatrix. SAS exhibits the following key features: (1) strong enhancement of the buildup of neutral density in a localized region near the plasma strike point on the divertor target; (2) spreading of the cooling front across the divertor target with the slot gradually flaring out from the strike point, thus effectively reducing both heat flux and erosion on the entire divertor target surface. Such a divertor may potentially provide a power and particle handling solution for long pulse advanced tokamaks.

  20. Impact of the impurity seeding for divertor protection on the performance of fusion reactors

    Science.gov (United States)

    Siccinio, Mattia; Fable, Emiliano; Angioni, Clemente; Saarelma, Samuli; Scarabosio, Andrea; Zohm, Hartmut

    2017-10-01

    A 0D divertor and scrape-off layer (SOL) model has been coupled to the 1.5D core transport code ASTRA. The resulting numerical tool has been employed for various parameter scans in order to identify the most convenient choices for the operation of electricity producing fusion devices with seeded impurities for the divertor protection. In particular, the repercussions of such radiative species on the main plasma through the fuel dilution have been taken into account. The main result we found is that, when the limits on the maximum tolerable divertor heat flux are enforced, the curves at constant electrical power output are closed on themselves in the R-BT plane, i.e. no improvement would descend from a further increase of R or BT once the maximum has been reached. This occurrence appears as an intrinsic physical limit for all devices where a radiative SOL is needed to deal with the power exhaust. Furthermore, the relative importance of the different power loss channels (e.g. hydrogen radiation, charge exchange, perpendicular transport and impurity radiation), through which the power entering the SOL is dissipated before reaching the target plate, is investigated with our model.

  1. Divertor Heat Flux Reduction by Resonant Magnetic Perturbations in the LHD-Type Helical DEMO Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Yanagi, N.; Sagara, A.; Goto, T.; Masuzaki, S.; Miyazawa, J., E-mail: yanagi@lhd.nifs.ac.jp [National Institute for Fusion Science, Toki (Japan)

    2012-09-15

    Full text: The conceptual design studies of the LHD-type helical fusion DEMO reactor, FFHR-d1, are progressing steadfastly. The LHD-type heliotron magnetic configuration equipped with the built- in helical divertors has a potential to realize low divertor heat flux in spatial average. However, the toroidal asymmetry may give more than a couple of times higher peak heat flux at some locations, as has been experimentally observed in LHD and confirmed by magnetic field-line tracing. By providing radiation dispersion accompanied with a plasma detachment, the heat flux may decrease significantly though the compatibility with a good core plasma confinement is an important issue to be explored. Whereas the engineering difficulties for developing materials to be used under the neutron environment require even further decrease of the heat flux (even though the heliotron is a unique configuration that divertor plates be largely shielded from the direct irradiation of neutrons by breeder blankets). In this respect, we proposed, in the last IAEA FEC, a new strike point sweeping scheme using a set of auxiliary helical coils, termed helical divertor (HD) coils. The HD coils carrying a few percent of the current amplitude of the main helical coils sweep the divertor strike points without altering the core plasma. Though this scheme is effective in dispersing the heat flux in the poloidal direction, the toroidal asymmetry still remains. The AC operation may also give unforeseen engineering difficulties. We here propose that the peak heat flux be mitigated using RMP fields in steady-state. The magnetic field-lines are numerically traced in the vacuum configuration and their footprints coming to the divertor regions are counted. Their fraction plotted as a function of the toroidal angle indicates that the peak heat flux be mitigated to {approx} 20 MW per square meters at 3 GW fusion power generation without having radiation dispersion when an RMP field is applied. We note that the

  2. A tangentially viewing visible TV system for the DIII-D divertor

    International Nuclear Information System (INIS)

    Fenstermacher, M.E.; Meyer, W.H.; Wood, R.D.; Nilson, D.G.; Ellis, R.; Brooks, N.H.

    1997-01-01

    A video camera system has been installed on the DIII-D tokamak for two-dimensional spatial studies of line emission in the lower divertor region. The system views the divertor tangentially at approximately the height of the X point through an outer port. At the tangency plane, the entire divertor from the inner wall to outside the DIII-D bias ring is viewed with spatial resolution of ∼1 cm. The image contains information from ∼90 deg of toroidal angle. In a recent upgrade, remotely controllable filter changers were added which have produced images from nominally identical discharges using different spectral lines. Software was developed to calculate the response function matrix of the optical system using distributed computing techniques and assuming toroidal symmetry. Standard sparse matrix algorithms are then used to invert the three-dimensional images onto a poloidal plane. Spatial resolution of the inverted images is 2 cm; higher resolution simply increases the size of the response function matrix. Initial results from a series of experiments with multiple identical discharges show that the emission from CII and CIII, which appears along the inner scrape-off layer above and below the X point during ELMing H mode, moves outward and becomes localized near the X point in radiative divertor operation induced by deuterium injection. copyright 1997 American Institute of Physics

  3. An X-point ergodic divertor

    International Nuclear Information System (INIS)

    Chu, M.S.; Jensen, T.H.; La Haye, R.J.; Taylor, T.S.; Evans, T.E.

    1991-10-01

    A new ergodic divertor is proposed. It utilizes a system of external (n = 3) coils arranged to generate overlapping magnetic islands in the edge region of a diverted tokamak and connect the randomized field lines to the external (cold) divertor plate. The novel feature in the configuration is the placement of the external coils close to the X-point. A realistic design of the external coil set is studied by using the field line tracing method for a low aspect ratio (A ≅ 3) tokamak. Two types of effects are observed. First, by placing the coils close to the X-point, where the poloidal magnetic field is weak and the rational surfaces are closely packed only a moderate amount of current in the external coils is needed to ergodize the edge region. This ergodized edge enhances the edge transport in the X-point region and leads to the potential of edge profile control and the avoidance of edge localized modes (ELMs). Furthermore, the trajectories of the field lines close to the X-point are modified by the external coil set, causing the hit points on the external divertor plates to be randomized and spread out in the major radius direction. A time-dependent modulation of the currents in the external (n = 3) coils can potentially spread the heat flux more uniformly on the divertor plate avoiding high concentration of the heat flux. 10 refs., 9 figs

  4. The ITER Divertor Cassette Project meeting

    International Nuclear Information System (INIS)

    Akiba, M.; Tivey, R.

    2000-01-01

    The Divertor Cassette Project topical meeting took place on April 5-7, 2000 at the JAERI Naka site in Japan. The meeting focused on the progress made by the three parties under task agreements on the development of carbon-fibre composite and tungsten armored high flux plasma-facing components

  5. Compact poloidal divertor reference design for TNS

    International Nuclear Information System (INIS)

    Yang, T.F.; Lee, A.Y.; Ruck, G.W.; Lange, W.J.

    1977-01-01

    A compact poloidal divertor concept has been developed for TNS tokamaks and its feasibility has been demonstrated by sufficient detailed magnetic, thermal, mechanical and vacuum analyses. This particular divertor is formed by a pair of opposing coil sets which define a magnetic flux slot where the particle burial chamber is located. The magnetic flux in the space between the coil sets is compressed vertically to limit the height and to expand the horizontal width of the particle and energy burial chamber. The intensity of the poloidal field is increased to make the pitch angle of the flux lines very large so that the diverted particles can be intercepted by a large number of panels oriented at a small angle with respect to the flux lines. Large collecting surface areas can be obtained so that the thermal load and particle flux are reduced to a practical level. Flowing lithium film and solid metal panels have been considered as the particle collector and the latter is preferred. This divertor allows for most economical use of the available space inside the TF coils and thus has minor impact on the overall size of the tokamak. The divertor design is essentially independent of the tokamak system, although analyses were performed based on TNS

  6. Modelling of neutral particle transport in divertor plasma

    International Nuclear Information System (INIS)

    Kakizuka, Tomonori; Shimizu, Katsuhiro

    1995-01-01

    An outline of the modelling of neutral particle transport in the diverter plasma was described in the paper. The characteristic properties of divertor plasma were largely affected by interaction between neutral particles and divertor plasma. Accordingly, the behavior of neutral particle should be investigated quantitatively. Moreover, plasma and neutral gas should be traced consistently in the plasma simulation. There are Monte Carlo modelling and the neutral gas fluid modelling as the transport modelling. The former need long calculation time, but it is able to make the physical process modelling. A ultra-large parallel computer is good for the former. In spite of proposing some kinds of models, the latter has not been established. At the view point of reducing calculation time, a work station is good for the simulation of the latter, although some physical problems have not been solved. On the Monte Carlo method particle modelling, reducing the calculation time and introducing the interaction of particles are important subjects to develop 'the evolutional Monte Carlo Method'. To reduce the calculation time, two new methods: 'Implicit Monte Carlo method' and 'Free-and Diffusive-Motion Hybrid Monte-Carlo method' have been developing. (S.Y.)

  7. Studies of a poloidal divertor reversed field pinch

    International Nuclear Information System (INIS)

    Sarff, J.S.; Almagri, A.F.; Assadi, S.; Den Hartog, D.J.; Dexter, R.N.; Prager, S.C.; Sprott, J.C.

    1988-07-01

    An attempt has been made to form a reversed field pinch (RFP) in a poloidal divertor configuration which position the plasma far from a conducting wall. In this configuration, the plasma is localized within a magnetic separatrix formed by the combination of toroidal currents in the plasma and four internal aluminum rings. Plasmas were formed with plasma current /approximately/135 kA, toroidal field reversal lasting /approximately/1 msec, line-averaged density /approximately/1--2 /times/ 10 13 cm/sup /minus/3/ and central electron temperature /approximately/55 eV, but a large asymmetry in the magnetic field (δB/B /approximately/40%) onset at about the time the toroidal field reversed at the wall. Symmetric, poloidal divertor RFP equilibria were not formed. This behavior might be expected based on linear MHD stability analysis of a cylindrical plasma bounded by a large vacuum region and distant conducting wall. The symmetric equilibrium before the asymmetry develops and the asymmetry itself are described. 15 refs., 3 figs

  8. Thermoluminescent behavior of diamond thin films exposed to ultraviolet radiation

    International Nuclear Information System (INIS)

    Barboza F, M.; Gastelum, S.; Melendrez, R.; Chernov, V.; Bernal, R.; Cruz V, C.; Brown, F.

    2002-01-01

    In this work the thermoluminescent properties of diamond thin films are discussed which are grown up through the chemical vapor method exposed to ultraviolet radiation of 200-280 nm. The films with thickness 3, 6, 9, 12, 180 and 500 microns were grown up using a precursor gas formed of H 2 -CH 4 -CO excited through microwave energy or hot filament.The structure and morphology of the films were examined through scanning electron microscopy, indicating the formation of different diamond polycrystal structures which depend on the type of heating of the precursor gas used as well as the film dimensions. In general, the brilliance curve depends on the sample and the wavelength of the irradiation ultraviolet light, however it presents clearly thermoluminescence bands in 148, 160, 272, 304, 320 and 324 C degrees. The maximum of the thermoluminescence efficiency is obtained for the case of sample exposure with light of 214 nm. The sample of 500 microns is what exhibits greater thermoluminescent efficiency of those studied samples. The thermoluminescent behavior in function of radiation dose presents regions of linearity and supra linearity for higher and small doses respectively. The disappearance of the thermoluminescent signal depends on the characteristics of the film and it can reach until a 30 % of loss before to reach the stability. (Author)

  9. Improved performance of the W7-AS stellarator with the new island divertor

    International Nuclear Information System (INIS)

    Brakel, R.; Grigull, P.; McCormick, K.

    2003-01-01

    The island divertor concept has successfully been realized at W7-AS. The divertor gives access to a new NBI-heated high density regime with densities up to 4x1020 m-3 and energy confinement well above customary scalings (high density H-mode, HDH). In parallel, impurity confinement dramatically decreases. This prevents impurity accumulation, and allows for quasi-stationary high density discharges with excellent confinement and with radiation profiles peaked at the edge. At the highest densities partial detachment occurs with a radiated power fraction up to 90% at a tolerable mitigation of plasma energy. The HDH-mode appears promising with respect to the requirements of both confinement and exhaust. Major experimental results, such as the lack of a high recycling phase preceding detachment, are also predicted by the EMC3/EIRENE code. (author)

  10. Divertor erosion in DIII-D

    International Nuclear Information System (INIS)

    Whyte, D.G.; Bastasz, R.; Wampler, W.R.; Brooks, J.N.; West, W.P.; Wong, C.P.C.; Buzhinskij, O.I.; Opimach, I.V.

    1998-08-01

    Net erosion rates of carbon target plates have been measured in situ for the DIII-D lower divertor. The principal method of obtaining this data is the DiMES sample probe. Recent experiments have focused on erosion at the outer strike-point (OSP) of two divertor plasma conditions: attached (T e > 40 eV) ELMing plasmas, and detached (T e 2 . In this case, measurements and modeling agree for both gross and net carbon erosion, showing the near-surface transport and redeposition of the carbon is well understood. In the attached cases, physical sputtering (with enhancement from self-sputtering and oblique incidence) is dominant, and the effective sputtering yield, Y, is greater than 10%. In ELM-free discharges, the total OSP net erosion rate is equal to the rate of carbon accumulation in the core plasma. For the detached divertor cases, the cold incident plasma eliminates physical sputtering. Attempts to measure chemically eroded hydrocarbon molecules spectroscopically indicate an upper limit of Y ≤ 0.1% for the chemical sputtering yield. Net erosion is suppressed at the outer strike-point, which becomes a region of net redeposition (∼ 4 cm/exposure-year). The private flux wall is measured to be a region of net redeposition with dense, high neutral pressure, attached divertor plasmas. Leading edges intercepting parallel heat flux (∼ 50 MW/m 2 ) have very high net erosion rates at the OSP of an attached plasma (∼ 10 microm/s > 1,000x erosion rate of aligned surfaces). Leading edge erosion, and subsequent carbon redeposition, caused by tile gaps can account for half of the deuterium codeposition in the DIII-D divertor

  11. Divertor erosion in DIII-D

    International Nuclear Information System (INIS)

    Whyte, D.G.; Bastasz, R.; Wampler, W.R.; Brooks, J.N.; West, W.P.; Wong, C.P.C.

    1998-05-01

    Net erosion rates of carbon target plates have been measured in situ for the DIII-D lower divertor. The principal method of obtaining this data is the DiMES sample probe. Recent experiments have focused on erosion at the outer strike-point of two divertor plasma conditions: (1) attached (Te > 40 eV) ELMing plasmas and (2) detached (Te 10 cm/year, even with incident heat flux 2 . In this case, measurements and modeling agree for both gross and net carbon erosion, showing the near-surface transport and redeposition of the carbon is well understood and that effective sputtering yields are > 10%. In ELM-free discharges, this erosion rate can account for the rate of carbon accumulation in the core plasma. Divertor plasma detachment eliminates physical sputtering, while spectroscopically measured chemical erosion yields are also found to be low (Y(C/D + ) ≤ 2.0 x 10 -3 ). This leads to suppression of net erosion at the outer strike-point, which becomes a region of net redeposition (∼ 4 cm/year). The private flux wall is measured to be a region of net redeposition with dense, high neutral pressure, attached divertor plasmas. Leading edges intercepting parallel heat flux (∼ 50 MW/m 2 ) have very high net erosion rates (∼ 10 microm/s) at the OSP of an attached plasma. Leading edge erosion, and subsequent carbon redeposition, caused by tile gaps can account for half of the deuterium codeposition in the DIII-D divertor

  12. Operating conditions of the BPX divertor

    International Nuclear Information System (INIS)

    Hill, D.N.; Milovich, J.; Rognlien, T.; Braams, B.J.; Brooks, J.N.; Campbell, R.; Haines, J.; Knoll, D.; Prinja, A.; Stotler, D.P.; Ulrickson, M.

    1991-01-01

    In this paper we discuss the expected operating conditions at the divertor of the BPX tokamak (Burning Plasma Experiment), the next- step US tokamak proposed for the study of self-heated plasmas at Q ≅ 5 to ignition. In this double-null device (κ ≅ 2), the predicted first-wall loading is high because of is compact size (R = 2.6m, α = 0.8m, I p = 10.6 MA, and B T ) and its high projected fusion power output (100--500 MW with up to 20 MW of ICRH). Present designs call for inertially cooled carbon-based target plate material and X-point sweeping to handle the divertor heat flux during the 3--5 s flat-top at full power. The X-point is maintained about 15--20 cm off the target plates (a distance of ∼5m along field lines), which represents a reasonable compromise between lowering the divertor electron temperature (T e,d ) by increasing the connection length, and lowering the peak divertor heat flux (q d ) by increasing the magnetic flux expansion (which is about 15--20 in this case). It is planned for the BPX device to operate with H-mode confinement; ELMs are expected because of the relatively high power flow through the edge plasma (P sep ≅ 0.6 MW/m 2 for P fus = 500 MW). The ELMs will help reduce the impurity concentration in the core plasma (Z eff ≅ 1.7) and keep the density down, but should not add significantly to the divertor heat flux since their measured contribution to the global power balance drops with increasing input power

  13. Erosion of ITER divertor armour and contamination of sol after transient events erosion products

    International Nuclear Information System (INIS)

    Bazylev, B.N.; Landman, I.S.; Pestchanyi, S.E.

    2005-01-01

    Plasma impact to the divertor expected in the tokamak ITER during ELMs or disruptions can result in a significant surface damage to CFC- and tungsten armours (brittle destruction and melting respectively) as well as in contamination of SOL by evaporated impurities. Numerical investigations for tungsten and CFC targets provide important details of the material erosion process. The simulations carried out in FZK on the material damage, carbon plasma expansion and the radiation fluxes from the carbon impurity are surveyed

  14. Transient thermal hydraulic modeling and analysis of ITER divertor plate system

    International Nuclear Information System (INIS)

    El-Morshedy, Salah El-Din; Hassanein, Ahmed

    2009-01-01

    A mathematical model has been developed/updated to simulate the steady state and transient thermal-hydraulics of the International Thermonuclear Experimental Reactor (ITER) divertor module. The model predicts the thermal response of the armour coating, divertor plate structural materials and coolant channels. The selected heat transfer correlations cover all operating conditions of ITER under both normal and off-normal situations. The model also accounts for the melting, vaporization, and solidification of the armour material. The developed model is to provide a quick benchmark of the HEIGHTS multidimensional comprehensive simulation package. The present model divides the coolant channels into a specified axial regions and the divertor plate into a specified radial zones, then a two-dimensional heat conduction calculation is created to predict the temperature distribution for both steady and transient states. The model is benchmarked against experimental data performed at Sandia National Laboratory for both bare and swirl tape coolant channel mockups. The results show very good agreements with the data for steady and transient states. The model is then used to predict the thermal behavior of the ITER plasma facing and structural materials due to plasma instability event where 60 MJ/m 2 plasma energy is deposited over 500 ms. The results for ITER divertor response is analyzed and compared with HEIGHTS results.

  15. Transient thermal hydraulic modeling and analysis of ITER divertor plate system

    Energy Technology Data Exchange (ETDEWEB)

    El-Morshedy, Salah El-Din [Argonne National Laboratory, Argonne, IL (United States); Atomic Energy Authority, Cairo (Egypt)], E-mail: selmorshedy@etrr2-aea.org.eg; Hassanein, Ahmed [Purdue University, West Lafayette, IN (United States)], E-mail: hassanein@purdue.edu

    2009-12-15

    A mathematical model has been developed/updated to simulate the steady state and transient thermal-hydraulics of the International Thermonuclear Experimental Reactor (ITER) divertor module. The model predicts the thermal response of the armour coating, divertor plate structural materials and coolant channels. The selected heat transfer correlations cover all operating conditions of ITER under both normal and off-normal situations. The model also accounts for the melting, vaporization, and solidification of the armour material. The developed model is to provide a quick benchmark of the HEIGHTS multidimensional comprehensive simulation package. The present model divides the coolant channels into a specified axial regions and the divertor plate into a specified radial zones, then a two-dimensional heat conduction calculation is created to predict the temperature distribution for both steady and transient states. The model is benchmarked against experimental data performed at Sandia National Laboratory for both bare and swirl tape coolant channel mockups. The results show very good agreements with the data for steady and transient states. The model is then used to predict the thermal behavior of the ITER plasma facing and structural materials due to plasma instability event where 60 MJ/m{sup 2} plasma energy is deposited over 500 ms. The results for ITER divertor response is analyzed and compared with HEIGHTS results.

  16. SOLPS-ITER Study of neutral leakage and drift effects on the alcator C-Mod divertor plasma

    Directory of Open Access Journals (Sweden)

    W. Dekeyser

    2017-08-01

    Full Text Available As part of an effort to validate the edge plasma model in the SOLPS-ITER code suite under ITER-relevant divertor plasma and neutral conditions, we report on progress in the modeling of the Alcator C-Mod divertor plasma with the new code. We perform simulations with a complete drifts model and kinetic neutrals, including effects of neutral viscosity, ion-molecule collisions and Lyα-opaque conditions, but assuming a pure deuterium plasma. Through a series of simulations with varying divertor geometries, we show the importance of including neutal leakage paths through the divertor substructure on the divertor plasma solution. Moreover, the impact of drifts on inner-outer target asymmetries is assessed. Including both effects, we achieve excellent agreement between simulations and upstream and outer target Langmuir Probe data. In absence of strong volumetric losses due to e.g. impurity radiation in our simulations, the strong inner target detachment observed experimentally remains elusive in our modeling at present.

  17. Current profile control and magnetohydrodynamic stability in Tore Supra discharges with edge-plasma control by the ergodic divertor

    International Nuclear Information System (INIS)

    Zabiego, M.; Friant, C.; Ghendrih, P.; Becoulet, M.; Bucalossi, J.; Saint-Laurent, F.

    1999-01-01

    Although ergodic divertors are primarily designed to control particle and heat fluxes at the plasma edge, they also happen to affect the MHD stability of tokamak discharges. On Tore Supra, the ergodic divertor has long been known to stabilize the m/n=2/1 tearing mode induced, for instance, by edge radiation and detachment processes, thus allowing safe high-current and high-density operations. More recently, though, in discharges where ergodic divertor operations were optimised relative to the control of the edge-plasma (i.e., with large divertor perturbation), a detrimental increase in the disruptiveness has been observed. The action that the ergodic divertor has on the MHD activity is interpreted in terms of a redistribution of the current profile. The latter results from a large increase in the edge resistivity, primarily induced by the degradation of the electron energy confinement in the ergodic layer. The possibility that a transport barrier develops in the vicinity of the separatrix strongly affects the considered modelling. (authors)

  18. The isotope effect on divertor conditions and neutral pumping in horizontal divertor configurations in JET-ILW Ohmic plasmas

    Directory of Open Access Journals (Sweden)

    J. Uljanovs

    2017-08-01

    Full Text Available Understanding the impact of isotope mass and divertor configuration on the divertor conditions and neutral pressures is critical for predicting the performance of the ITER divertor in DT operation. To address this need, ohmically heated hydrogen and deuterium plasma experiments were conducted in JET with the ITER-like wall in varying divertor configurations. In this study, these plasmas are simulated with EDGE2D-EIRENE outfitted with a sub-divertor model, to predict the neutral pressures in the plenum with similar fashion to the experiments. EDGE2D-EIRENE predictions show that the increased isotope mass results in up to a 25% increase in peak electron densities and 15% increase in peak ion saturation current at the outer target in deuterium when compared to hydrogen for all horizontal divertor configurations. Indicating that a change from hydrogen to deuterium as main fuel decreases the neutral mean free path, leading to higher neutral density in the divertor. Consequently, this mechanism also leads to higher neutral pressures in the sub-divertor. The experimental data provided by the hydrogen and deuterium ohmic discharges shows that closer proximity of the outer strike point to the pumping plenum results in a higher neutral pressure in the sub-divertor. The diaphragm capacitance gauge pressure measurements show that a two to three-fold increase in sub-divertor pressure was achieved in the corner and nearby horizontal configurations compared to the far-horizontal configurations, likely due to ballistic transport (with respect to the plasma facing components of the neutrals into the sub-divertor. The corner divertor configuration also indicates that a neutral expansion occurs during detachment, resulting in a sub-divertor neutral density plateau as a function of upstream density at the outer-mid plane.

  19. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety management of radiation workers in medical institutions

    International Nuclear Information System (INIS)

    Han, Eun Ok

    2007-01-01

    Radiation safety managements in medical institutions are needed to protect certain radiation damages as a part of National Coalition. This study investigates the characteristics of self-efficacy that become the major factor on the knowledge, attitude, and behavior on the radiation safety management of radiation workers as an approach of educational aspects and analyzes the relationship between such factors to provide basic materials for improving the activity level of radiation safety managements. In order to implement the goal of this study, a survey was performed for 1,200 workers who were engaged in radiation treatments in medical centers, such as general hospital, university hospital, private hospital, and public health center for 42 days from July 23, 2006. Then, the results of the analysis can be summarized as follows: 1. Average scores on knowledge, attitude, and behavior in the radiation safety management were presented as 75.76±11.20, 90.55±8.59, 80.58±11.70, respectively. Also, the average score of self-efficacy was recorded as 73.55±9.82. 2. Knowledge levels in the radiation safety management showed significant differences according to the sex, age, marriage, education, and experience. Also, males of married, older, highly educated, and largely experienced represented high knowledge levels. Attitude levels in the radiation safety management showed certain significant differences according to the type of medical centers in which private hospitals showed a relatively low level compared to that of high levels in university hospitals. Behavior levels in the radiation safety management also represented significant differences according to the age, marriage, education, experience, and types of medical centers. Factors in married, general hospital, older, highly educated, and largely experienced showed high behavior levels. In addition, the self-efficacy showed certain differences according to the marriage and types of medical centers. Factors in married

  20. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety management of radiation workers in medical institutions

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Ok [Daegu Health College, Daegu (Korea, Republic of)

    2007-06-15

    Radiation safety managements in medical institutions are needed to protect certain radiation damages as a part of National Coalition. This study investigates the characteristics of self-efficacy that become the major factor on the knowledge, attitude, and behavior on the radiation safety management of radiation workers as an approach of educational aspects and analyzes the relationship between such factors to provide basic materials for improving the activity level of radiation safety managements. In order to implement the goal of this study, a survey was performed for 1,200 workers who were engaged in radiation treatments in medical centers, such as general hospital, university hospital, private hospital, and public health center for 42 days from July 23, 2006. Then, the results of the analysis can be summarized as follows: 1. Average scores on knowledge, attitude, and behavior in the radiation safety management were presented as 75.76{+-}11.20, 90.55{+-}8.59, 80.58{+-}11.70, respectively. Also, the average score of self-efficacy was recorded as 73.55{+-}9.82. 2. Knowledge levels in the radiation safety management showed significant differences according to the sex, age, marriage, education, and experience. Also, males of married, older, highly educated, and largely experienced represented high knowledge levels. Attitude levels in the radiation safety management showed certain significant differences according to the type of medical centers in which private hospitals showed a relatively low level compared to that of high levels in university hospitals. Behavior levels in the radiation safety management also represented significant differences according to the age, marriage, education, experience, and types of medical centers. Factors in married, general hospital, older, highly educated, and largely experienced showed high behavior levels. In addition, the self-efficacy showed certain differences according to the marriage and types of medical centers. Factors in

  1. Examining Innovative Divertor and Main Chamber Options for a National Divertor Test Tokamak

    Science.gov (United States)

    Labombard, B.; Umansky, M.; Brunner, D.; Kuang, A. Q.; Marmar, E.; Wallace, G.; Whyte, D.; Wukitch, S.

    2016-10-01

    The US fusion community has identified a compelling need for a National Divertor Test Tokamak. The 2015 Community Planning Workshop on PMI called for a national working group to develop options. Important elements of a NDTT, adopted from the ADX concept, include the ability to explore long-leg divertor `solutions for power exhaust and particle control' (Priority Research Direction B) and to employ inside-launch RF actuators combined with double-null topologies as `plasma solution for main chamber wall components, including tools for controllable sustained operation' (PRD-C). Here we examine new information on these ideas. The projected performance of super-X and X-point target long-leg divertors is looking very promising; a stable fully-detached divertor condition handling an order-of-magnitude increase in power handling over conventional divertors may be possible. New experiments on Alcator C-Mod are addressing issues of high-field side versus low-field side heat flux sharing in double-null topologies and the screening of impurities that might originate from RF actuators placed in the high-field side - both with favorable results. Supported by USDoE Awards DE-FC02-99ER54512 and DE-AC52-07NA27344.

  2. Characteristics of the Secondary Divertor on DIII-D

    Science.gov (United States)

    Watkins, J. G.; Lasnier, C. J.; Leonard, A. W.; Evans, T. E.; Pitts, R.; Stangeby, P. C.; Boedo, J. A.; Moyer, R. A.; Rudakov, D. L.

    2009-11-01

    In order to address a concern that the ITER secondary divertor strike plates may be insufficiently robust to handle the incident pulses of particles and energy from ELMs, we performed dedicated studies of the secondary divertor plasma and scrape-off layer (SOL). Detailed measurements of the ELM energy and particle deposition footprint on the secondary divertor target plates were made with a fast IR camera and Langmuir probes and SOL profile and transport measurements were made with reciprocating probes. The secondary divertor and SOL conditions depended on changes in the magnetic balance and the core plasma density. Larger density resulted in smaller ELMs and the magnetic balance affected how many ELM particles coupled to the secondary SOL and divertor. Particularly striking are the images from a new fast IR camera that resolve ELM heat pulses and show spiral patterns with multiple peaks during ELMs in the secondary divertor.

  3. Modeling detachment physics in the NSTX snowflake divertor

    Energy Technology Data Exchange (ETDEWEB)

    Meier, E.T., E-mail: emeier@wm.edu [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Bell, R.E.; Diallo, A.; Kaita, R.; LeBlanc, B.P. [Princeton Plasma Physics Laboratory, Princeton, NJ 08540 (United States); McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States); Podestà, M. [Princeton Plasma Physics Laboratory, Princeton, NJ 08540 (United States); Rognlien, T.D.; Scotti, F. [Lawrence Livermore National Laboratory, Livermore, CA 94551 (United States)

    2015-08-15

    The snowflake divertor is a proposed technique for coping with the tokamak power exhaust problem in next-step experiments and eventually reactors, where extreme power fluxes to material surfaces represent a leading technological and physics challenge. In lithium-conditioned National Spherical Torus Experiment (NSTX) discharges, application of the snowflake divertor typically induced partial outer divertor detachment and severalfold heat flux reduction. UEDGE is used to analyze and compare conventional and snowflake divertor configurations in NSTX. Matching experimental upstream profiles and divertor measurements in the snowflake requires target recycling of 0.97 vs. 0.91 in the conventional case, implying partial saturation of the lithium-based pumping mechanism. Density scans are performed to analyze the mechanisms that facilitate detachment in the snowflake, revealing that increased divertor volume provides most of the parallel heat flux reduction. Also, neutral gas power loss is magnified by the increased wetted area in the snowflake, and plays a key role in generating volumetric recombination.

  4. ITER tungsten divertor design development and qualification program

    Energy Technology Data Exchange (ETDEWEB)

    Hirai, T., E-mail: takeshi.hirai@iter.org [ITER Organization, Route de Vinon sur Verdon, F-13115 Saint Paul lez Durance (France); Escourbiac, F.; Carpentier-Chouchana, S.; Fedosov, A.; Ferrand, L.; Jokinen, T.; Komarov, V.; Kukushkin, A.; Merola, M.; Mitteau, R.; Pitts, R.A.; Shu, W.; Sugihara, M. [ITER Organization, Route de Vinon sur Verdon, F-13115 Saint Paul lez Durance (France); Riccardi, B. [F4E, c/ Josep Pla, n.2, Torres Diagonal Litoral, Edificio B3, E-08019 Barcelona (Spain); Suzuki, S. [JAEA, Fusion Research and Development Directorate JAEA, 801-1 Mukouyama, Naka, Ibaragi 311-0193 (Japan); Villari, R. [Associazione EURATOM-ENEA sulla Fusione, Via Enrico Fermi 45, I-00044 Frascati, Rome (Italy)

    2013-10-15

    Highlights: • Detailed design development plan for the ITER tungsten divertor. • Latest status of the ITER tungsten divertor design. • Brief overview of qualification program for the ITER tungsten divertor and status of R and D activity. -- Abstract: In November 2011, the ITER Council has endorsed the recommendation that a period of up to 2 years be set to develop a full-tungsten divertor design and accelerate technology qualification in view of a possible decision to start operation with a divertor having a full-tungsten plasma-facing surface. To ensure a solid foundation for such a decision, a full tungsten divertor design, together with a demonstration of the necessary high performance tungsten monoblock technology should be completed within the required timescale. The status of both the design and technology R and D activity is summarized in this paper.

  5. Role of molecular effects in divertor plasma recombination

    Directory of Open Access Journals (Sweden)

    A.S. Kukushkin

    2017-08-01

    Full Text Available Molecule-Activated Recombination (MAR effect is re-considered in view of divertor plasma conditions. A strong isotopic effect is demonstrated. In deuterium plasmas, the reaction chain through D2+ formation, usually considered dominant and included in 2D edge plasma models, is negligible. However, in this case the other branch, through D−, usually neglected in modelling, becomes relatively strong. The overall share of MAR in divertor plasma recycling stays within 20%. The operational parameters of the divertor plasmas, such as the peak power loading on the divertor targets or the pressure limit for partial detachment of the divertor plasma, are insensitive to the presence of MAR, although the latter may be important for correct interpretation of the divertor diagnostics.

  6. Divertor, thermonuclear device and method of neutralizing high temperature plasma

    International Nuclear Information System (INIS)

    Ikegami, Hideo.

    1995-01-01

    The thermonuclear device comprises a thermonuclear reactor for taking place fusion reactions to emit fusion plasmas, and a divertor made of a hydrogen occluding material, and the divertor is disposed at a position being in contact with the fusion plasmas after nuclear fusion reaction. The divertor is heated by fusion plasmas after nuclear fusion reaction, and hydrogen is released from the hydrogen occluding material as a constituent material. A gas blanket is formed by the released hydrogen to cool and neutralize the supplied high temperature nuclear fusion plasmas. This prevents the high temperature plasmas from hitting against the divertor, elimination of the divertor by melting and evaporation, and solve a problem of processing a divertor activated by neutrons. In addition, it is possible to utilize hydrogen isotopes of fuels effectively and remove unnecessary helium. Inflow of impurities from out of the system can also be prevented. (N.H.)

  7. Effects of low-Z and high-Z impurities on divertor detachment and plasma confinement

    Directory of Open Access Journals (Sweden)

    H.Q. Wang

    2017-08-01

    Full Text Available The impurity-seeded detached divertor is essential for heat exhaust in ITER and other reactor-relevant devices. Dedicated experiments with injection of N2, Ne and Ar have been performed in DIII-D to assess the impact of the different impurities on divertor detachment and confinement. Seeding with N2, Ne and Ar all promote divertor detachment, greatly reducing heat flux near the strike point. The upstream plasma density at the onset of detachment decreases with increasing impurity-puffing flow rates. For all injected impurity species, the confinement and pedestal pressure are correlated with the impurity content and the ratio of separatrix loss power to the l-H transition threshold power. As the divertor plasma approaches detachment, the high-Z impurity seeding tends to degrade the core confinement owing to the increased core radiation. In particular, Ar injection with up to 50% of the injected power radiating in the core cools the pedestal and core plasmas, thus significantly degrading the confinement. As for Ne seeding, medium confinement with H98∼0.8 can be maintained during the detachment phase with the pedestal temperature being reduced by about 50%. In contrast, in the N2 seeded plasmas, radiation is predominately confined in the boundary plasma, which leads to less effect on the confinement and pedestal. In the case of strong N2 gas puffing, the confinement recovers during the detachment, from ∼20% reduction at the onset of the detachment to greater than unity comparable to that before the seeding. The core and pedestal temperatures feature a reduction of 30% from the initial attached phase and remain nearly constant during the detachment phase. The improvement in confinement appears to arise from the increase in pedestal and core density despite the temperature reduction.

  8. SLAC divertor channel entrance thermal stress analysis

    International Nuclear Information System (INIS)

    Johnson, G.L.; Stein, W.; Lu, S.C.; Riddle, R.A.

    1985-01-01

    X-ray beams emerging from the new SLAC electron-positron storage ring (PEP) impinge on the entrance to tangential divertor channels causing highly localized heating in the channel structure. Analyses were completed to determine the temperatures and thermally-induced stresses due to this heating. These parts are cooled with water flowing axially over them at 30 0 C. The current design and operating conditions should result in the entrance to the new divertor channel operating at a peak temperature of 123 0 C with a peak thermal stress at 91% of yield. Any micro-cracks that form due to thermally-induced stresses should not propagate to the coolant wall nor form a path for the coolant to leak into the storage ring vacuum. 34 figs., 4 tabs

  9. Thermal effects of divertor sweeping in ITER

    International Nuclear Information System (INIS)

    Wesley, J.C.

    1992-01-01

    In this paper, thermal effects of magnetically sweeping the separatrix strike point on the outer divertor target of the International Thermonuclear Fusion Reactor (ITER) are calculated. For the 0. 2 Hz x ± 12 cm sweep scenario proposed for ITER operations, the thermal capability of a generic target design is found to be slightly inadequate (by ∼ 5%) to accommodate the full degree of plasma scrape-off peaking postulated as a design basis. The principal problem identified is that the 5 s sweep period is long relative to the 1. 4 s thermal time constant of the divertor target. An increase of the sweep frequency to ∼ 1 Hz is suggested: this increase would provide a power handling margin of ∼ 25% relative to present operational criteria

  10. He-cooled divertor development for DEMO

    International Nuclear Information System (INIS)

    Norajitra, P.; Giniyatulin, R.; Ihli, T.; Janeschitz, G.; Krauss, W.; Kruessmann, R.; Kuznetsov, V.; Mazul, I.; Widak, V.; Ovchinnikov, I.; Ruprecht, R.; Zeep, B.

    2007-01-01

    Goal of the He-cooled divertor development for future fusion power plants is to resist a high heat flux of at least 10 MW/m 2 . The development includes the fields of design, analyses, and experiments. A helium-cooled modular jet concept (HEMJ) has been defined as reference solution, which is based on jet impingement cooling. In cooperation with the Efremov Institute, work was aimed at construction and high heat flux tests of prototypical tungsten mockups to demonstrate their manufacturability and their performances. A helium loop was built for this purpose to simulate the realistic thermo-hydraulics conditions close to those of DEMO (10 MPa He, 600 deg. C). The first high heat flux test results confirm the feasibility and the performance of the divertor design

  11. Module of lithium divertor for KTM tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Lyublinski, I., E-mail: yublinski@yandex.ru [FSUE ' Red Star' , Moscow (Russian Federation); Vertkov, A.; Evtikhin, V.; Balakirev, V.; Ionov, D.; Zharkov, M. [FSUE ' Red Star' , Moscow (Russian Federation); Tazhibayeva, I. [IAE NNC RK, Kurchatov (Kazakhstan); Mirnov, S. [TRINITI, Troitsk, Moscow Region (Russian Federation); Khomiakov, S.; Mitin, D. [OJSC Dollezhal Institute, Moscow (Russian Federation); Mazzitelli, G. [ENEA RC Frascati (Italy); Agostini, P. [ENEA RC Brasimone (Italy)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Problems of PFE degradation, tritium accumulation and plasma pollution can be overcome by the use of liquid lithium-metal with low Z. Black-Right-Pointing-Pointer Capillary-porous system (CPS) - new material in which liquid lithium fill a solid matrix from porous material. Black-Right-Pointing-Pointer Lithium divertor module for KTM tokamak is under development. Black-Right-Pointing-Pointer Lithium filled tungsten felt is offered as the base plasma facing material of divertor. Black-Right-Pointing-Pointer Results of this project addresses to the progress in the field of fusion neutrons source and fusion energy source creation. - Abstract: Activity on projects of ITER and DEMO reactors has shown that solution of problems of divertor target plates and other plasma facing elements (PFEs) based on the solid plasma facing materials cause serious difficulties. Problems of PFE degradation, tritium accumulation and plasma pollution can be overcome by the use of liquid lithium-metal with low Z. Application of lithium will allow to create a self-renewal and MHD stable liquid metal surface of the in-vessel devices possessing practically unlimited service life; to reduce power flux due to intensive re-irradiation on lithium atoms in plasma periphery that will essentially facilitate a problem of heat removal from PFE; to reduce Z{sub eff} of plasma to minimally possible level close to 1; to exclude tritium accumulation, that is provided with absence of dust products and an opportunity of the active control of the tritium contents in liquid lithium. Realization of these advantages is based on use of so-called lithium capillary-porous system (CPS) - new material in which liquid lithium fill a solid matrix from porous material. The progress in development of lithium technology and also activity in lithium experiments in the tokamaks TFTR, T-11M, T-10, FTU, NSTX, HT-7 and stellarator TJ II permits of solving the problems in development of

  12. Boundary plasma control with the ergodic divertor

    International Nuclear Information System (INIS)

    Ghendrih, Ph.; Becoulet, M.; Beyer, P.

    1999-01-01

    Ergodic divertor experiments on Tore Supra provide evidence of significant control of plasma-wall interaction. Theoretical investigation of the laminar region (i.e. governed by parallel transport) indicates that control of the plasma state at the target plate can be achieved with plasma states similar to that observed with the axisymmetric divertor. Analysis of the temperature field with a 2-D test particle code allows one to recover the observed spatial modulation and shows that an intrinsic barrier appears to develop at the separatrix. Energy deposition peaking, analysed with a 3-D code, is strongly reduced when moderate transverse transport is considered. Possible control of upstream parameters can thus be achieved in the ergodic region, for instance a lowering of the parallel energy flux by cross field transport. (author)

  13. Boundary plasma control with the ergodic divertor

    International Nuclear Information System (INIS)

    Ghendrih, Ph.; Becoulet, M.; Beyer, P.

    2001-01-01

    Ergodic divertor experiments on Tore Supra provide evidence of significant control of plasma-wall interaction. Theoretical investigation of the laminar region (i.e. governed by parallel transport) indicates that control of the plasma state at the target plate can be achieved with plasma states similar to that observed with the axisymmetric divertor. Analysis of the temperature field with a 2-D test particle code allows one to recover the observed spatial modulation and shows that an intrinsic barrier appears to develop at the separatrix. Energy deposition peaking, analysed with a 3-D code, is strongly reduced when moderate transverse transport is considered. Possible control of upstream parameters can thus be achieved in the ergodic region, for instance a lowering of the parallel energy flux by cross field transport. (author)

  14. Electron beam facility for divertor target experiments

    International Nuclear Information System (INIS)

    Anisimov, A.; Gagen-Torn, V.; Giniyatulin, R.N.

    1994-01-01

    To test different concepts of divertor targets and bumpers an electron beam facility was assembled in Efremov Institute. It consists of a vacuum chamber (3m 3 ), vacuum pump, electron beam gun, manipulator to place and remove the samples, water loop and liquid metal loop. The following diagnostics of mock-ups is stipulated: (1) temperature distribution on the mock-up working surface (scanning pyrometer and infra-red imager); (2) temperature distribution over mocked-up thickness in 3 typical cross-sections (thermo-couples); (3) cracking dynamics during thermal cycling (acoustic-emission method), (4) defects in the mock-up before and after tests (ultra-sonic diagnostics, electron and optical microscopes). Carbon-based and beryllium mock-ups are made for experimental feasibility study of water and liquid-metal-cooled divertor/bumper concepts

  15. Plasma diagnostics for the DIII-D divertor upgrade (abstract)

    International Nuclear Information System (INIS)

    Hill, D.N.; Futch, A.; Buchenauer, D.; Doerner, R.; Lehmer, R.; Schmitz, L.; Klepper, C.C.; Menon, M.; Leikind, B.; Lippmann, S.; Mahdavi, M.A.; Schaffer, M.; Smith, J.; Salmonson, J.; Watkins, J.

    1990-01-01

    The DIII-D tokamak is being upgraded to allow for divertor biasing, baffling, and pumping experiments. This paper gives an overview of the new diagnostics added to DIII-D as part of this advanced divertor program. They include tile current monitors, fast reciprocating Langmuir probes, a fixed probe array in the divertor, fast neutral pressure gauges, and H α measurements with TV cameras and fiber optics coupled to a high-resolution spectrometer

  16. Comparative divertor-transport study for helical devices

    International Nuclear Information System (INIS)

    Feng, Y.; Sardei, F.; Kobayashi, M.

    2008-10-01

    Using the island divertors (ID) of W7-AS and W7-X and the helical divertor (HD) of LHD as examples, the paper presents a comparative divertor transport study for three typical helical devices of different machine-size following two distinct divertor concepts, aiming at identifying common physics issues/effects for mutual validation and combined studies. Based on EMC3/EIRENE simulations supported by experimental results, the paper first reviews and compares the essential transport features of the W7-AS ID and the LHD HD in order to build a base and framework for a predictive study of W7-X. Revealed is the fundamental role of the low-order magnetic islands in both divertor concepts. Preliminary EMC3/EIRENE simulation results for W7-X are presented and discussed with respect to W7-AS and LHD in order to show how the individual field and divertor topologies affect the divertor transport and performance. For instance, a high recycling regime which is absent from W7-AS and LHD is expected for W7-X. Topics addressed are restricted to the basic function elements of a divertor such as particle flux enhancement and impurity retention. In particular, the divertor function on reducing the influx of intrinsic impurities is examined for all the three devices under different divertor plasma conditions. Special attention is paid to examining the island screening potential of intrinsic impurities which has been predicted for all the three devices under high divertor collisionality conditions. The results are discussed in conjunction with the experimental observations for high density divertor plasmas in W7-AS and LHD. (author)

  17. Experimental studies of the snowflake divertor in TCV

    Directory of Open Access Journals (Sweden)

    B. Labit

    2017-08-01

    Full Text Available To address the risk that, in a fusion reactor, the conventional single-null divertor (SND configuration may not be able to handle the power exhaust, alternative divertor configurations, such as the Snowflake divertor (SFD, are investigated in TCV. The expected benefits of the SFD-minus in terms of power load and peak heat flux are discussed and compared to experimental measurements. In addition, key results obtained during the last years are summarized.

  18. A Model for Protective Behavior against the Harmful Effects of Radiation based on Medical Institution Classifications

    International Nuclear Information System (INIS)

    Han, Eun Ok; Kwon, Deok Mun; Dong, Kyung Rae; Han, Seung Moo

    2010-01-01

    This study surveyed a total of 1,322 radiation technologist in health care institutions throughout Korea. This is a comparative study conducted on the levels of protective behavior against the harmful effects of radiation in heath care institutions which indicated that university hospitals and general hospitals showed higher level of protective behavior than for medical practitioners. This study found university hospitals have the following 7 characteristics to manage protective behavior against the harmful effects of radiation, protective environment, self-efficacy by distinction of task , self-efficacy, expectation of the protective behavior, the number of patients, level of the education related to the protection of the harmful effects of radiation and protective attitude. While general hospitals have the following 3 characteristics protective environment, expectation of the protective behavior and protective attitude. Hospitals have the following 4 characteristics protective environment, expectation of the protective behavior, protective attitude and self-efficacy and medical clinics have characteristics protective environment

  19. A Model for Protective Behavior against the Harmful Effects of Radiation based on Medical Institution Classifications

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Ok; Kwon, Deok Mun [Daegu Health College, Daegu (Korea, Republic of); Dong, Kyung Rae [Gwangju Health College University, Gwangju (Korea, Republic of); Han, Seung Moo [Kyung Hee University, Seoul (Korea, Republic of)

    2010-12-15

    This study surveyed a total of 1,322 radiation technologist in health care institutions throughout Korea. This is a comparative study conducted on the levels of protective behavior against the harmful effects of radiation in heath care institutions which indicated that university hospitals and general hospitals showed higher level of protective behavior than for medical practitioners. This study found university hospitals have the following 7 characteristics to manage protective behavior against the harmful effects of radiation, protective environment, self-efficacy by distinction of task , self-efficacy, expectation of the protective behavior, the number of patients, level of the education related to the protection of the harmful effects of radiation and protective attitude. While general hospitals have the following 3 characteristics protective environment, expectation of the protective behavior and protective attitude. Hospitals have the following 4 characteristics protective environment, expectation of the protective behavior, protective attitude and self-efficacy and medical clinics have characteristics protective environment.

  20. Two-point model for divertor transport

    International Nuclear Information System (INIS)

    Galambos, J.D.; Peng, Y.K.M.

    1984-04-01

    Plasma transport along divertor field lines was investigated using a two-point model. This treatment requires considerably less effort to find solutions to the transport equations than previously used one-dimensional (1-D) models and is useful for studying general trends. It also can be a valuable tool for benchmarking more sophisticated models. The model was used to investigate the possibility of operating in the so-called high density, low temperature regime

  1. Divertor and scoop limiter experiments on PDX

    International Nuclear Information System (INIS)

    McGuire, K.; Beiersdorfer, P.; Bell, M.

    1985-01-01

    Routine operation in the enhanced energy confinement (or H-mode) regime during neutral beam injection was achieved by modifying the PDX divertor hardware to inhibit the influx of neutral gas from the divertor region to the main plasma chamber. A particle scoop limiter has been studied as a mechanical means of controlling particles at the plasma edge, and neutral beam heated discharges with this limiter show similar confinement times (normalized to tau/sub E//I/sub p/) to average H-mode plasmas. Two new instabilities are observed near the plasma edge in PDX during H-mode operation. The first, a quasicoherent fluctuation, occurred in bursts at well-defined frequencies (Δω/ω less than or equal to 0.1) in the range 50 to 180 kHz, and had no obvious effects on confinement. The second instability, the edge relaxation phenomena (ERP), did cause deterioration in the global confinement time. The ERP's are characterized by sharp spikes in the divertor plasma density, H/sub α/ emission, and on the x-ray signals they appear as sawtoothlike relaxations at the plasma edge with an inversion radius near the separatrix. Attempts to obtain high β/sub T/ in the H-mode discharges were hampered by a deterioration in the H-mode confinement and major disruptions which limited the achievable β/sub T/. A study of the stability of both the limiter L-mode and divertor H-mode discharges close to the theoretical β boundary, showed that the major disruptions observed there are sometimes caused by a fast growing m/n = 1/1 mode with no observable external precursor oscillations

  2. Divertor and scoop limiter experiments on PDX

    International Nuclear Information System (INIS)

    McGuire, K.; Beirsdorfer, P.; Bell, M.

    1985-01-01

    Routine operation in the enhanced-energy-confinement (or H-mode) regime during neutral-beam injection was achieved by modifying the PDX divertor hardware to inhibit the influx of neutral gas from the divertor region to the main plasma chamber. A particle scoop limiter has been studied as a mechanical means of controlling particles at the plasma edge, and neutral-beam-heated discharges with this limiter show similar confinement times (normalized to tausub(E)/Isub(p)) to average H-mode plasma. Two new instabilities are observed near the plasma edge in PDX during H-mode operation. The first, a quasi-coherent fluctuation, occurred in bursts at well-defined frequencies (Δω/ω<=0.1) in the range 50 to 180 kHz, and had no obvious effects on confinement. The second instability, the edge relaxation phenomena (ERP), did cause deterioration in the global confinement time. The ERPs are characterized by sharp spikes in the divertor plasma density, Hsub(α) emission, and on the X-ray signals they appear as sawtooth-like relaxations at the plasma edge with an inversion radius near the separatrix. Attempts to obtain high βsub(T) in the H-mode discharges were hampered by a deterioration in the H-mode confinement and major disruptions which limited the achievable βsub(T). A study of the stability of both the limiter L-mode and divertor H-mode discharge close to the theoretical β boundary showed that the major disruptions observed there are sometimes caused by a fast growing m/n=1/1 mode with no observable external precursor oscillations. (author)

  3. The remote exchange of the JET divertor

    International Nuclear Information System (INIS)

    Pick, M.

    1999-01-01

    In 1997 a series of experiments were performed in the JET machine using deuterium-tritium (D-T) mixtures and resulting in discharges with record breaking fusion power and fusion energy. The experiments demonstrated a key technology required for fusion, namely the on-line operation of a tritium fuel re-processing plant. These experiments left the inside of the JET vessel inaccessible to manned access for approximately one year. During this time, the complete Mark IIA divertor, a major system within the torus, was successfully removed and replaced with a new divertor design, the Mark II Gas Box divertor, using only remote handling techniques. This was the first application of the JET remote handling system and a demonstration of a further key ITER technology. The paper explains the methodology and operational approach taken to achieve the results using the remote handling system developed at JET. It describes the remote handling equipment including the force-reflecting servo-manipulator, the specialised tools designed, the facilities needed, and the trials, planning and training carried out to ensure the safe, reliable and rapid completion of the remote handling tasks. The planned tasks are outlined including the execution of the novel procedure for a remote, sub-millimetre precision, dimensional survey of the divertor support structure using digital photogrammetry. Furthermore the paper shows how the adaptability of the system was used to successfully undertake a large number of unplanned tasks including the removal of damaged tiles, a damaged diagnostic system and the vacuum cleaning of diagnostic windows. (author)

  4. Studies of power exhaust and divertor design for a 1.5 GW-level fusion power DEMO

    Science.gov (United States)

    Asakura, N.; Hoshino, K.; Suzuki, S.; Tokunaga, S.; Someya, Y.; Utoh, H.; Kudo, H.; Sakamoto, Y.; Hiwatari, R.; Tobita, K.; Shimizu, K.; Ezato, K.; Seki, Y.; Ohno, N.; Ueda, Y.; Joint Special TeamDEMO Design

    2017-12-01

    Power exhaust to the divertor and the conceptual design have been investigated for a steady-state DEMO in Japan with 1.5 GW-level fusion power and the major radius of 8.5 m, where the plasma parameters were revised appropriate for the impurity seeding scenario. A system code survey for the Ar impurity seeding suggested the volume-averaged density, impurity concentration and exhaust power from the main plasma of {{P}sep ~ }   =  205-285 MW. The divertor plasma simulation (SONIC) was performed in the divertor leg length of 1.6 m with the fixed exhaust power to the edge of {{P}out}   =  250 MW and the total radiation fraction at the edge, SOL and divertor ({{P}rad}/{{P}out}   =  0.8), as a first step to investigate appropriate design of the divertor size and geometry. At the outer target, partial detachment was produced near the strike-point, and the peak heat load ({{q}target} ) at the attached region was reduced to ~5 MW m-2 with appropriate fuel and impurity puff rates. At the inner divertor target, full detachment of ion flux was produced and the peak {{q}target} was less than 10 MW m-2 mostly due to the surface-recombination. These results showed a power exhaust scenario and the divertor design concept. An integrated design of the water-cooling heat sink for the long leg divertor was proposed. Cu-ally (CuCrZr) cooling pipe was applicable as the heat sink to handle the high heat flux near the strike-point, where displacements per atom rate was estimated to be 0.5-1.5 per year by neutronics calculation. An arrangement of the coolant rooting for Cu-alloy and Reduced Activation Ferritic Martensitic (RAFM) steel (F82H) pipes in a divertor cassette was investigated, and the heat transport analysis of the W-monoblock and Cu-alloy pipe under the peak {{q}target} of 10 MWm-2 and nuclear heating was performed. The maximum temperatures on the W-surface and Cu-alloy pipe were 1021 and 331 °C. Heat flux of 16 MW m-2 was distributed in the major part

  5. Towards a physics-integrated view on divertor pumping

    International Nuclear Information System (INIS)

    Day, Chr.; Gleason-González, C.; Hauer, V.; Igitkhanov, Y.; Kalupin, D.; Varoutis, S.

    2014-01-01

    Highlights: • Physics-integrated design approaches are to be preferred over approaches based on simple requirement lists. • A physics-integrated assessment is presented for the divertor vacuum pumping system based on detachment onset conditions for the divertor. • This approach considers density dependent pump albedo to reflect the effects of gas recycling at the divertor and the changes in flow regime with density. • A comparison with DEMO indicates that the divertor pumping system for a pulsed DEMO scales less than linearly with fusion power. - Abstract: One key requirement to design the inner fuel cycle of a divertor tokamak is defined by the torus vessel gas throughput and composition, and the sub-divertor neutral pressure at which the exhaust gas has to be pumped. This paper illustrates how divertor physics aspects can be translated to requirements on the divertor vacuum pumping system. An example workflow is presented that links the realization of detachment conditions with the sub-divertor neutral gas flow patterns in order to determine the appropriate number of torus vacuum pumps. For the example case of a fusion DEMO size machine, it was found that 7 actively pumping cryopumps (ITER-type) are necessary to handle the gas throughput that is needed to manage the heat flux and densities related to detachment onset

  6. FLP: a field line plotting code for bundle divertor design

    International Nuclear Information System (INIS)

    Ruchti, C.

    1981-01-01

    A computer code was developed to aid in the design of bundle divertors. The code can handle discrete toroidal field coils and various divertor coil configurations. All coils must be composed of straight line segments. The code runs on the PDP-10 and displays plots of the configuration, field lines, and field ripple. It automatically chooses the coil currents to connect the separatrix produced by the divertor to the outer edge of the plasma and calculates the required coil cross sections. Several divertor designs are illustrated to show how the code works

  7. Influence of stray light for divertor spectroscopy in ITER

    International Nuclear Information System (INIS)

    Kajita, Shin; Veshchev, Evgeny; Lisgo, Steve; Barnsley, Robin; Morgan, Philip; Walsh, Michael; Ogawa, Hiroaki; Sugie, Tatsuo; Itami, Kiyoshi

    2015-01-01

    The influence of stray light in the divertor spectroscopy system in ITER is quantitatively investigated using a ray tracing simulation. Simulation results show that the stray light is negligible at positions in the divertor where the plasma emission is strong. However, it is also shown that the stray light can be significantly greater than the real signal if the plasma intensity is low. Deuterium and beryllium emissions are used for the assessment; for beryllium cases in particular, since the emission profile may be non-uniform in the divertor region, the influence of stray light can be non-negligible at some positions, e.g., above the divertor dome

  8. Technological development of the Monobloc Divertor Concept

    International Nuclear Information System (INIS)

    DiPietro, E.; Brossa, M.; Guerreschi, U.; Suresh, D.; Cardella, A.

    1992-01-01

    This paper reports on a technological program devoted to the assessment of the feasibility and the qualification of the Monobloc Divertor Concept for the divertor of the NET/ITER Machine which has been developed with the joint collaboration between ENEA, the NET Team, Ansaldo DNT and Metallwerk Plansee. The basic idea guiding the development of the monobloc divertor consists in obtaining a component suitable to sustain the operation thermal loads, attaining peak values in the range of 15 MW/2 in steady state conditions, by a proper arrangement of refractory tiles (acting as an armour) directly brazed to the cooling pipes. In the first phase the main activities have been devoted to find a reliable joint between the armour and the cooling pipes. A number of candidate armour materials have been investigated chosen among the most promising CFC currently available in combination with molybdenum alloys (T2M and Mo41Re) and dispersion strengthened copper. The most relevant results of the test activity including the comparison of different brazing alloys and techniques and the evaluation of suitable NDE techniques are reported

  9. Westinghouse compact poloidal divertor reference design

    International Nuclear Information System (INIS)

    Yang, T.F.; Lee, A.Y.; Ruck, G.W.

    1977-08-01

    A feasible compact poloidal divertor system has been designed as an impurity control and vacuum vessel first-wall protection option for the TNS tokamak. The divertor coils are inside the TF coil array and vacuum vessel. The poloidal divertor is formed by a pair of coil sets with zero net current. Each set consists of a number of coils forming a dish-shaped washer-like ring. The magnetic flux in the space between the coil sets is compressed vertically to limit the height and to expand the horizontal width of the particle and energy burial chamber which is located in the gap between the coil sets. The intensity of the poloidal field is increased to make the pitch angle of the flux lines very large so that the diverted particles can be intercepted by a large number of panels oriented at a small angle with respect to the flux lines. They are carefully shaped and designed such that the entire surfaces are exposed to the incident particles and are not shadowed by each other. Large collecting surface areas can be obtained. Flowing liquid lithium film and solid metal panels have been considered as the particle collectors. The power density for the former is designed at 1 MW/m 2 and for the latter 0.5 MW/m 2 . The major mechanical, thermal, and vacuum problems have been evaluated in sufficient detail so that the advantages and difficulties are identified. A complete functional picture is presented

  10. THERMAL HYDRAULIC ANALYSIS OF FIRE DIVERTOR

    International Nuclear Information System (INIS)

    C.B. bAXI; M.A. ULRICKSON; D.E. DRIMEYER; P. HEITZENROEDER

    2000-01-01

    The Fusion Ignition Research Experiment (FIRE) is being designed as a next step in the US magnetic fusion program. The FIRE tokamak has a major radius of 2 m, a minor radius of 0.525 m, and liquid nitrogen cooled copper coils. The aim is to produce a pulse length of 20 s with a plasma current of 6.6 MA and with alpha dominated heating. The outer divertor and baffle of FIRE are water cooled. The worst thermal condition for the outer divertor and baffle is the baseline D-T operating mode (10 T, 6.6 MA, 20 s) with a plasma exhaust power of 67 MW and a peak heat flux of 20 MW/m 2 . A swirl tape (ST) heat transfer enhancement method is used in the outer divertor cooling channels to increase the heat transfer coefficient and the critical heat flux (CHF). The plasma-facing surface consists of tungsten brush. The finite element (FE) analysis shows that for an inlet water temperature of 30 C, inlet pressure of 1.5 MPa and a flow velocity of 10 m/s, the incident critical heat flux is greater than 30 MW/m 2 . The peak copper temperature is 490 C, peak tungsten temperature is 1560 C, and the pressure drop is less than 0.5 MPa. All these results fulfill the design requirements

  11. A new scaling for divertor detachment

    Science.gov (United States)

    Goldston, R. J.; Reinke, M. L.; Schwartz, J. A.

    2017-05-01

    The ITER design, and future reactor designs, depend on divertor ‘detachment,’ whether partial, pronounced or complete, to limit heat flux to plasma-facing components and to limit surface erosion due to sputtering. It would be valuable to have a measure of the difficulty of achieving detachment as a function of machine parameters, such as input power, magnetic field, major radius, etc. Frequently the parallel heat flux, estimated typically as proportional to P sep/R or P sep B/R, is used as a proxy for this difficulty. Here we argue that impurity cooling is dependent on the upstream density, which itself must be limited by a Greenwald-like scaling. Taking this into account self-consistently, we find the impurity fraction required for detachment scales dominantly as power divided by poloidal magnetic field. The absence of any explicit scaling with machine size is concerning, as P sep surely must increase greatly for an economic fusion system, while increases in the poloidal field strength are limited by coil technology and plasma physics. This result should be challenged by comparison with 2D divertor codes and with measurements on existing experiments. Nonetheless, it suggests that higher magnetic field, stronger shaping, double-null operation, ‘advanced’ divertor configurations, as well as alternate means to handle heat flux such as metallic liquid and/or vapor targets merit greater attention.

  12. Island divertor studies on W7-AS

    International Nuclear Information System (INIS)

    Sardei, F.; Feng, Y.; Grigull, P.; Herre, G.; Hildebrandt, D.; Hofmann, J.V.; Kisslinger, J.; Brakel, R.; Das, J.; Geiger, J.; Heinrich, O.; Kuehner, G.; Niedermeyer, H.; Reiter, D.; Richter-Gloetzl, M.; Runov, A.; Schneider, R.; Stroth, U.; Verbeek, H.; Wagner, F.; Wolf, R.

    1997-01-01

    Basic topological features of the island divertor concept for low shear stellarators are discussed with emphasis on the differences to tokamak divertors. Extensive measurements of the edge structures by two-dimensional plasma spectroscopy and by target calorimetry are in excellent agreement with predicted vacuum and equilibrium configurations, which are available up to central β values of ∝1%. For this β value the calculated field-line pitch inside the islands is twice that of the corresponding vacuum case. Video observations of the strike points indicate stability of the island structures for central β values up to ∝3.7%. The interpretation of the complex island divertor physics of W7-AS has become possible by the development of the three-dimensional plasma transport code EMC3 (Edge Monte Carlo 3D), which has been coupled self-consistently to the EIRENE neutral gas code. Analysis of high density NBI discharges gives strong indications of stable high recycling conditions for n e ≥10 20 m -3 . The observations are reproduced by the EMC3/EIRENE code and supported by calculations with the B2/EIRENE code adapted to W7-AS. Improvement of recycling, pumping and target load distribution is expected from the new optimized target plates and baffles to be installed in W7-AS. (orig.)

  13. Heat flux management via advanced magnetic divertor configurations and divertor detachment

    Energy Technology Data Exchange (ETDEWEB)

    Kolemen, E., E-mail: ekolemen@princeton.edu [Princeton University, Princeton, NJ 08544 (United States); Allen, S.L. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Bray, B.D. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Fenstermacher, M.E. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Humphreys, D.A.; Hyatt, A.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Lasnier, C.J. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Leonard, A.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Makowski, M.A.; McLean, A.G. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Maingi, R.; Nazikian, R. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Petrie, T.W. [General Atomics, PO Box 85608, San Diego, CA 92186-5608 (United States); Soukhanovskii, V.A. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States); Unterberg, E.A. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831 (United States)

    2015-08-15

    The snowflake divertor (SFD) control and detachment control to manage the heat flux at the divertor are successfully demonstrated at DIII-D. Results of the development and implementation of these two heat flux reduction control methods are presented. The SFD control algorithm calculates the position of the two null-points in real-time and controls shaping coil currents to achieve and stabilize various snowflake configurations. Detachment control stabilizes the detachment front fixed at specified distance between the strike point and the X-point throughout the shot.

  14. Melt damage simulation of W-macrobrush and divertor gaps after multiple transient events in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Bazylev, B.N. [Forschungszentrum Karlsruhe, IHM, P.O. Box 3640, 76021 Karlsruhe (Germany)]. E-mail: bazylev@ihm.fzk.de; Janeschitz, G. [Forschungszentrum Karlsruhe, Fusion, P.O. Box 3640, 76021 Karlsruhe (Germany); Landman, I.S. [Forschungszentrum Karlsruhe, IHM, P.O. Box 3640, 76021 Karlsruhe (Germany); Loarte, A. [EFDA-CSU, Max-Planck-Institut fuer Plasmaphysik, D-85748 Garching (Germany); Pestchanyi, S.E. [Forschungszentrum Karlsruhe, IHM, P.O. Box 3640, 76021 Karlsruhe (Germany)

    2007-06-15

    Tungsten in the form of macrobrush structure is foreseen as one of two candidate materials for the ITER divertor and dome. In ITER, even for moderate and weak ELMs when a thin shielding layer does not protect the armour surface from the dumped plasma, the main mechanisms of metallic target damage remain surface melting and melt motion erosion, which determines the lifetime of the plasma facing components. The melt erosion of W-macrobrush targets with different geometry of brush surface under the heat loads caused by weak ELMs is numerically investigated using the modified code MEMOS. The optimal angle of brush surface inclination that provides a minimum of surface roughness is estimated for given inclination angles of impacting plasma stream and given parameters of the macrobrush target. For multiple disruptions the damage of the dome gaps and the gaps between divertor cassettes caused by the radiation impact is estimated.

  15. Melt damage simulation of W-macrobrush and divertor gaps after multiple transient events in ITER

    Science.gov (United States)

    Bazylev, B. N.; Janeschitz, G.; Landman, I. S.; Loarte, A.; Pestchanyi, S. E.

    2007-06-01

    Tungsten in the form of macrobrush structure is foreseen as one of two candidate materials for the ITER divertor and dome. In ITER, even for moderate and weak ELMs when a thin shielding layer does not protect the armour surface from the dumped plasma, the main mechanisms of metallic target damage remain surface melting and melt motion erosion, which determines the lifetime of the plasma facing components. The melt erosion of W-macrobrush targets with different geometry of brush surface under the heat loads caused by weak ELMs is numerically investigated using the modified code MEMOS. The optimal angle of brush surface inclination that provides a minimum of surface roughness is estimated for given inclination angles of impacting plasma stream and given parameters of the macrobrush target. For multiple disruptions the damage of the dome gaps and the gaps between divertor cassettes caused by the radiation impact is estimated.

  16. Melt damage simulation of W-macrobrush and divertor gaps after multiple transient events in ITER

    International Nuclear Information System (INIS)

    Bazylev, B.N.; Janeschitz, G.; Landman, I.S.; Loarte, A.; Pestchanyi, S.E.

    2007-01-01

    Tungsten in the form of macrobrush structure is foreseen as one of two candidate materials for the ITER divertor and dome. In ITER, even for moderate and weak ELMs when a thin shielding layer does not protect the armour surface from the dumped plasma, the main mechanisms of metallic target damage remain surface melting and melt motion erosion, which determines the lifetime of the plasma facing components. The melt erosion of W-macrobrush targets with different geometry of brush surface under the heat loads caused by weak ELMs is numerically investigated using the modified code MEMOS. The optimal angle of brush surface inclination that provides a minimum of surface roughness is estimated for given inclination angles of impacting plasma stream and given parameters of the macrobrush target. For multiple disruptions the damage of the dome gaps and the gaps between divertor cassettes caused by the radiation impact is estimated

  17. The knowledge, attitude and behavior on the radiation safety management for dental hygiene major students

    International Nuclear Information System (INIS)

    Jeon, Yeo Reong; Cho, Pyong Kon; Kim, Yong Min; Han, Eun Ok; Jang, Hyon Chul; Ko, Jong Kyung

    2015-01-01

    This study tries to find the educational basis based on the radiation safety knowledge, attitudes and behaviors to check the level of radiation safety behavior in domestic students who study dental hygiene. The students of 3rd and 4th grades in 83 universities which have registered on the Korean University Education Council were involved, and they were given a questionnaire for this study. The questionnaire was provided via visit with 20 copies to each university (total 1660 copies), mail by post and e-mail. Among them, we analyzed only 723 copies that we can trust. The data were analyzed with frequency, percentage, mean, standard deviation and Pearson’s correlation using the SPSS/WIN 15.0. As a result, there are correlations in the students’ knowledge, attitudes and behaviors regarding the radiation safety management. It means that the education which can improve the knowledge and attitudes should be applied to increase the action level of the radiation safety. In addition, the physical environment is the most closely correlated with the individual behavior, so it will be limited to improve the behavioral levels of the radiation safety if the physical environment is not prepared. Therefore, the physical environment should be supported to enhance the level of the radiation safety activity, and to increase the individual attitude level of radiation safety. The knowledge level of the radiation safety management is relatively lower than the attitudes level, and the behavior level is the lowest. Therefore, the education policy of the safety behavior must be enhanced. For domestic students, the educational intervention is necessary to improve their behavioral level of radiation safety management because they will be able to reduce the amount of radiation exposure of their patients in dental care after getting a job

  18. The knowledge, attitude and behavior on the radiation safety management for dental hygiene major students

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Yeo Reong; Cho, Pyong Kon; Kim, Yong Min [Dept. of Radiological Science, Daegu Catholic University, Daegu (Korea, Republic of); Han, Eun Ok [Korea Academy of Nuclear Safety, Seoul (Korea, Republic of); Jang, Hyon Chul [Dept. of Radiological Technology, Suseong College, Daegu (Korea, Republic of); Ko, Jong Kyung [Radiation Safety Management Commission, Daegu Health College, (Korea, Republic of)

    2015-12-15

    This study tries to find the educational basis based on the radiation safety knowledge, attitudes and behaviors to check the level of radiation safety behavior in domestic students who study dental hygiene. The students of 3rd and 4th grades in 83 universities which have registered on the Korean University Education Council were involved, and they were given a questionnaire for this study. The questionnaire was provided via visit with 20 copies to each university (total 1660 copies), mail by post and e-mail. Among them, we analyzed only 723 copies that we can trust. The data were analyzed with frequency, percentage, mean, standard deviation and Pearson’s correlation using the SPSS/WIN 15.0. As a result, there are correlations in the students’ knowledge, attitudes and behaviors regarding the radiation safety management. It means that the education which can improve the knowledge and attitudes should be applied to increase the action level of the radiation safety. In addition, the physical environment is the most closely correlated with the individual behavior, so it will be limited to improve the behavioral levels of the radiation safety if the physical environment is not prepared. Therefore, the physical environment should be supported to enhance the level of the radiation safety activity, and to increase the individual attitude level of radiation safety. The knowledge level of the radiation safety management is relatively lower than the attitudes level, and the behavior level is the lowest. Therefore, the education policy of the safety behavior must be enhanced. For domestic students, the educational intervention is necessary to improve their behavioral level of radiation safety management because they will be able to reduce the amount of radiation exposure of their patients in dental care after getting a job.

  19. Analysis of directional radiative behavior and heating efficiency for a gas-fired radiant burner

    International Nuclear Information System (INIS)

    Li, B.X.; Lu, Y.P.; Liu, L.H.; Kudo, K.; Tan, H.P.

    2005-01-01

    For the purpose of energy conservation and uniform heating of object surface, a gas-fired porous radiant burner with a bundle of reflecting tubes is developed. A physical model is developed to simulate the directional radiative behavior of this heating device, in which the Monte Carlo method based on the concept of radiation distribution factor is used to compute the directional radiative behavior. The effects of relating parameters on the directional behavior of radiative heating and the heating efficiency are analyzed. With the increase of the length-to-radius ratio of tube, the radiation heating efficiency decreases, but the radiation energy incident on the object surface is more collimated. The radiation heating efficiency increases with the specular reflectivity. With the increase in length of tube segment with specular reflective surface, the radiation heating efficiency increases, but the extent of concentration and collimation of radiative energy decreases. For real design of the heating device, some trade-offs are needed to balance the radiation heating efficiency and the uniformity of radiative heating of object surface

  20. Plasma performance of Wendelstein 7-AS with the new boundary-island divertor modules

    International Nuclear Information System (INIS)

    McCormick, K.; Grigull, P.; Burhenn, R.; Brakel, R.; Ehmler, H.; Feng, Y.; Gadelmeier, F.; Giannone, L.; Hildebrandt, D.; Hirsch, M.; Jaenicke, R.; Kisslinger, J.; Klinger, T.; Klose, S.; Knauer, J.P.; Konig, R.; Kuhner, G.; Laqua, H.P.; Naujoks, D.; Niedermeyer, H.; Pasch, E.; Ramasubramanian, N.; Rust, N.; Sardei, F.; Wagner, F.; Weller, A.; Wenzel, U.; Werner, A.

    2002-01-01

    A promising new plasma operational regime on the Wendelstein stellarator W7-AS has been discovered. It is extant above a threshold density and characterized by flat density profiles, high energy- and low impurity-confinement times and edge-localized radiation. Impurity accumulation is avoided. Quasi-stationary discharges with line-averaged densities n e to 4x10 20 m -3 , radiation levels to 90%, and partial plasma detachment at the divertor target plates can be simultaneously realized. Energy confinement is up to twice that predicted by a conventional scaling. Copyright (2002) Australian National University- Research School of Physical Sciences and Engineering

  1. First tests of diagnostic mirrors in a tokamak divertor: An overview of experiments in DIII-D

    International Nuclear Information System (INIS)

    Litnovsky, A.; Rudakov, D.L.; De Temmerman, G.; Wienhold, P.; Philipps, V.; Samm, U.; McLean, A.G.; West, W.P.; Wong, C.P.C.; Brooks, N.H.; Watkins, J.G.; Wampler, W.R.; Stangeby, P.C.; Boedo, J.A.; Moyer, R.A.; Allen, S.L.; Fenstermacher, M.E.; Groth, M.; Lasnier, C.J.; Boivin, R.L.

    2008-01-01

    Mirrors will be used in ITER in all optical diagnostic systems observing the plasma radiation in the ultraviolet, visible and infrared ranges. Diagnostic mirrors in ITER will suffer from electromagnetic radiation, energetic particles and neutron irradiation. Erosion due to impact of fast neutrals from plasma and deposition of plasma impurities may significantly degrade optical and polarization characteristics of mirrors influencing the overall performance of the respective diagnostics. Therefore, maintaining the best possible performance of mirrors is of the crucial importance for the ITER optical diagnostics. Mirrors in ITER divertor are expected to suffer from deposition of impurities. The dedicated experiment in a tokamak divertor was needed to address this issue. Investigations with molybdenum diagnostic mirrors were made in DIII-D divertor. Mirror samples were exposed at different temperatures in the private flux region to a series of ELMy H-mode discharges with partially detached divertor plasmas. An increase of temperature of mirrors during the exposure generally led to the mitigation of carbon deposition, primarily due to temperature-enhanced chemical erosion of carbon layers by D atoms. Finally, for the mirrors exposed at the temperature of ∼160 o C neither carbon deposition nor degradation of optical properties was detected

  2. Variation of particle exhaust with changes in divertor magnetic balance

    International Nuclear Information System (INIS)

    Petrie, T.W.; Allen, S.L.; Brooks, N.H.

    2006-01-01

    Recent experiments on DIII-D point to the importance of two factors in determining how effectively the deuterium particle inventory in a tokamak plasma can be controlled through pumping at the divertor target(s): (1) the divertor magnetic balance, i.e. the degree to which the divertor topology is single-null or double-null (DN) and (2) the direction of the of B x ∇B ion drift with respect to the X-point(s). Changes in divertor magnetic balance near the DN shape have a much stronger effect on the particle exhaust rate at the inner divertor target(s) than on the particle exhaust rate at the outer divertor target(s). The particle exhaust rate for the DN shape is strongest at the outer strike point opposite the B x ∇B ion particle drift direction. Our data suggests that the presence of B x ∇B and E x B ion particle drifts in the scrape-off layer and divertor(s) play an important role in the particle exhaust rates of DN and near-DN plasmas. Particle exhaust rates are shown to depend strongly on the edge (pedestal) density. These results have implications for particle control in ITER and other future tokamaks

  3. Divertor impurity monitor for the International Thermonuclear Experimental Reactor

    Science.gov (United States)

    Sugie, T.; Ogawa, H.; Nishitani, T.; Kasai, S.; Katsunuma, J.; Maruo, M.; Ebisawa, K.; Ando, T.; Kita, Y.

    1999-01-01

    The divertor impurity monitoring system of the International Thermonuclear Experimental Reactor has been designed. The main functions of this system are to identify impurity species and to measure the two-dimensional distributions of the particle influxes in the divertor plasmas. The wavelength range is 200-1000 nm. The viewing fans are realized by molybdenum mirrors located in the divertor cassette. With additional viewing fans seeing through the gap between the divertor cassettes, the region approximately from the divertor leg to the x point will be observed. The light from the divertor region passes through the quartz windows on the divertor port plug and the cryostat, and goes through the dog-leg optics in the biological shield. Three different type of spectrometers: (i) survey spectrometers for impurity species monitoring, (ii) filter spectrometers for the particle influx measurement with the spatial resolution of 10 mm and the time resolution of 1 ms, and (iii) high dispersion spectrometers for high resolution wavelength measurements are designed. These spectrometers are installed just behind the biological shield (for λthe transmission loss in fiber and in the diagnostic room (for λ⩾450 nm) from the point of view of accessibility and flexibility. The optics have been optimized by a ray trace analysis. As a result, 10-15 mm spatial resolution will be achieved in all regions of the divertor.

  4. Physics design and experimental study of tokamak divertor

    International Nuclear Information System (INIS)

    Yan Jiancheng; Gao Qingdi; Yan Longwen; Wang Mingxu; Deng Baiquan; Zhang Fu; Zhang Nianman; Ran Hong; Cheng Fayin; Tang Yiwu; Chen Xiaoping

    2007-06-01

    The divertor configuration of HL-2A tokamak is optimized, and the plasma performance in divertor is simulated with B2-code. The effects of collisionality on plasma-wall transition in the scrape-off layer of divertor are investigated, high performances of the divertor plasma in HL-2A are simulated, and a quasi- stationary RS operation mode is established with the plasma controlled by LHCD and NBI. HL-2A tokamak has been successfully operated in divertor configuration. The major parameters: plasma current I p =320 kA, toroidal field B t =2.2 T, plasma discharger duration T d =1580 ms ware achieved at the end of 2004. The preliminary experimental researches of advanced diverter have been carried out. Design studies of divertor target plate for high power density fusion reactor have been carried out, especially, the physical processes on the surface of flowing liquid lithium target plate. The exploration research of improving divertor ash removal efficiency and reducing tritium inventory resulting from applying the RF ponderomotive force potential is studied. The optimization structure design studies of FEB-E reactor divertor are performed. High flux thermal shock experiments were carried on tungsten and carbon based materials. Hot Isostatic Press (HIP) method was employed to bond tungsten to copper alloys. Electron beam simulated thermal fatigue tests were also carried out to W/Cu bondings. Thermal desorption and surface modification of He + implanted into tungsten have been studied. (authors)

  5. Particle control in the DIII-D advanced divertor

    International Nuclear Information System (INIS)

    Schaffer, M.J.; Lippmann, S.I.; Mahdavi, M.A.; Petrie, T.W.; Stambaugh, R.D.; Hogan, J.; Klepper, C.C.; Mioduszewski, P.; Owen, L.; Hill, D.N.; Rensink, M.; Buchenauer, D.

    1991-11-01

    A new, electrically biasable, semi-closed divertor was installed and operated in the D3-D lower outside divertor location. The semi-closed divertor has yielded static gas pressure buildups in the pumping plenum in excess of 10 mtorr. (The planned cryogenic pumping is not yet installed). Electrical bias controls the distribution of particle recycle between the inner and outer divertors by rvec E x rvec B drifts. Depending on sign, bias increases or decreases the plenum gas pressure. Bias greatly reduce the sensitivity of plenum pressure to separatrix position. In particular, rvec E x rvec B drifts in the D3-D geometry can direct plasma across a divertor target and then optimally into the pumping aperture. Bias, even without active pumping, has also demonstrated a limited control of ELMing H-mode plasma density. 5 refs., 8 figs

  6. Structural analysis of the ITER Divertor toroidal rails

    Energy Technology Data Exchange (ETDEWEB)

    Viganò, F., E-mail: Fabio.Vigano@LTCalcoli.it [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Escourbiac, F.; Gicquel, S.; Komarov, V. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul lez Durance (France); Lucca, F. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Merola, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul lez Durance (France); Ngnitewe, R. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy)

    2013-10-15

    The Divertor is one of the most technically challenging components of the ITER machine, which has the main function of extracting the power conducted in the scrape-off layer while maintaining the plasma purity. There are 54 Divertor cassettes installed in the vacuum vessel (VV). Each cassette body (CB) is fastened on the inner and outer concentric Divertor toroidal rails. The comprehensive assessment (in accordance with the Structural Design Criteria for ITER In-vessel Components: ITER SDC-IC) of the Divertor toroidal rails has been performed during design activity based on performing of thermal and stress analyses at operating conditions of neutron stage of ITER operation. This paper outlines the engineering aspects of the ITER Divertor toroidal rails and focuses on some critical regions of the present design highlighted by the performed structural assessment. The structural assessment has been performed with help of using Finite Element (FE) Abaqus code and based on criteria given by ITER SDC-IC.

  7. Alternative divertor target concepts for next step fusion devices

    Science.gov (United States)

    Mazul, I. V.

    2016-12-01

    The operational conditions of a divertor target in the next steps of fusion devices are more severe in comparison with ITER. The current divertor designs and technologies have a limited application concerning these conditions, and so new design concepts/technologies are required. The main reasons which practically prevent the use of the traditional motionless solid divertor target are analyzed. We describe several alternative divertor target concepts in this paper. The comparative analysis of these concepts (including the advantages and the drawbacks) is made and the prospects for their practical implementation are prioritized. The concept of the swept divertor target with a liquid metal interlayer between the moving armour and motionless heat-sink is presented in more detail. The critical issues of this design are listed and outlined, and the possible experiments are presented.

  8. Simulation of the ASDEX divertor performance after hardening

    International Nuclear Information System (INIS)

    Schneider, W.; Lackner, K.; Neuhauser, J.; Wunderlich, R.

    1985-05-01

    Two combined computer models - a fluid description of the plasma scrape-off layer (SOLID) and a Monte-Carlo code for the neutral gas dynamics (DEGAS) - are used to assess changes in the divertor performance expected from the modifications in geometry needed for hardening the ASDEX divertor chamber for long-pulse, high-power heating. Stand-alone DEGAS calculations with assumed fixed scrape-off plasma parameters predict a doubling of the neutral escape probability, which, however, still remains so low, that achievement of the high divertor recycling regime can be expected over roughly the same operational regime as before modifications. This conclusion is also supported by fully self-consistent calculations with the combined model. Due to the reduced divertor, a significant reduction is predicted in the divertor time constant, which is expected to affect transient phenomena. (orig.)

  9. Integrated simulations of H-mode operation in ITER including core fuelling, divertor detachment and ELM control

    Science.gov (United States)

    Polevoi, A. R.; Loarte, A.; Dux, R.; Eich, T.; Fable, E.; Coster, D.; Maruyama, S.; Medvedev, S. Yu.; Köchl, F.; Zhogolev, V. E.

    2018-05-01

    ELM mitigation to avoid melting of the tungsten (W) divertor is one of the main factors affecting plasma fuelling and detachment control at full current for high Q operation in ITER. Here we derive the ITER operational space, where ELM mitigation to avoid melting of the W divertor monoblocks top surface is not required and appropriate control of W sources and radiation in the main plasma can be ensured through ELM control by pellet pacing. We apply the experimental scaling that relates the maximum ELM energy density deposited at the divertor with the pedestal parameters and this eliminates the uncertainty related with the ELM wetted area for energy deposition at the divertor and enables the definition of the ITER operating space through global plasma parameters. Our evaluation is thus based on this empirical scaling for ELM power loads together with the scaling for the pedestal pressure limit based on predictions from stability codes. In particular, our analysis has revealed that for the pedestal pressure predicted by the EPED1  +  SOLPS scaling, ELM mitigation to avoid melting of the W divertor monoblocks top surface may not be required for 2.65 T H-modes with normalized pedestal densities (to the Greenwald limit) larger than 0.5 to a level of current of 6.5–7.5 MA, which depends on assumptions on the divertor power flux during ELMs and between ELMs that expand the range of experimental uncertainties. The pellet and gas fuelling requirements compatible with control of plasma detachment, core plasma tungsten accumulation and H-mode operation (including post-ELM W transient radiation) have been assessed by 1.5D transport simulations for a range of assumptions regarding W re-deposition at the divertor including the most conservative assumption of zero prompt re-deposition. With such conservative assumptions, the post-ELM W transient radiation imposes a very stringent limit on ELM energy losses and the associated minimum required ELM frequency. Depending on

  10. Numerical exploration of non-axisymmetric divertor closure in the small angle slot (SAS) divertor at DIII-D

    Science.gov (United States)

    Frerichs, Heinke; Schmitz, Oliver; Covele, Brent; Guo, Houyang; Hill, David; Feng, Yuhe

    2017-10-01

    In the Small Angle Slot (SAS) divertor in DIII-D, the combination of misaligned slot structure and non-axisymmetric perturbations to the magnetic field causes the strike point to vary radially along the divertor slot and even leave it at some toroidal locations. This effect essentially introduces an opening in the divertor slot from where recycling neutrals can easily escape, and thereby degrade performance of the slot divertor. This effect has been approximated by a finite gap in the divertor baffle. Simulations with EMC3-EIRENE show that a toroidally localized loss of divertor closure can result in non-axisymmetric divertor densities and temperatures. This introduces a density window of 10-15% on top of the nominal threshold separatrix density during which a non-axisymmetric onset of local detachment occurs, initially leaving the gap and up to 60 deg beyond that still attached. Conversely, the impact of such toroidally localized divertor perturbations on the toroidal symmetry of midplane separatrix conditions is small. This work has been funded by the U.S. Department of Energy under Early Career Award Grant DE-SC0013911, and Grant DE-FC02-04ER54698.

  11. Design analysis of the ITER divertor

    International Nuclear Information System (INIS)

    Samuelli, G.; Marin, A.; Roccella, M.; Lucca, F.; Merola, M.; Riccardi, B.; Petrizzi, L.; Villari, R.

    2007-01-01

    The divertor is one of the most challenging components of the ITER machine. Its function is to reduce the impurity in the plasma and consists essentially of two parts: the plasma facing components (PFCs) and a massive support structure called the cassette body (CB). Considerable R and D effort (developed by EFDA CSU GARCHING and the ITER International Team together with the EU Associations and the EU Industries) has been spent in designing divertor components capable of withstanding the expected electromagnetic (EM) loads and to take into account the latest ITER design conditions. In support of such efforts extensive and very detailed Neutronic, Thermal, EM and Structural analyses have been performed. A summary of the analyses performed will be presented. One of the main result is a typical exercise of integration between the different kind of analyses and the importance of keeping the consistency between the different assumptions and simplifications. The models used for the numerical analyses include a detailed geometrical description of the CB, the inlet, outlet hydraulic manifolds, the CB to vacuum vessel locking system and three configurations of the PFU. The effect of electrical bridging, both in poloidal and toroidal direction, of the PFU castellation, due to a possible melting at the W mono-block or tiles, occurring during the plasma disruptions, has been analyzed. For all these configurations 2 VDE scenarios including the effect of the Toroidal Field Variation and the HaloCurrent with the related out of plane induced EM forces have been extensively analyzed and a detailed poloidal and radial distribution of the nuclear heating has been used for the neutronic flux on the divertor components. The aim of this activity is to produce a comprehensive design and assessment of the ITER divertor via: -The estimation of the neutronic heat deposition and shielding capability; -The calculation of the related thermal and mechanical effects and the comparison of the

  12. Design analysis of the ITER divertor

    Energy Technology Data Exchange (ETDEWEB)

    Samuelli, G.; Marin, A.; Roccella, M.; Lucca, F. [L.T. Calcoli SaS, Merate (Lecco) (Italy); Merola, M. [ITER Team, Cadarache (France); Riccardi, B. [EFDA CSU Garching (Germany); Petrizzi, L.; Villari, R. [CRE ENEA sulla Fusione Frascati, Roma (Italy)

    2007-07-01

    The divertor is one of the most challenging components of the ITER machine. Its function is to reduce the impurity in the plasma and consists essentially of two parts: the plasma facing components (PFCs) and a massive support structure called the cassette body (CB). Considerable R and D effort (developed by EFDA CSU GARCHING and the ITER International Team together with the EU Associations and the EU Industries) has been spent in designing divertor components capable of withstanding the expected electromagnetic (EM) loads and to take into account the latest ITER design conditions. In support of such efforts extensive and very detailed Neutronic, Thermal, EM and Structural analyses have been performed. A summary of the analyses performed will be presented. One of the main result is a typical exercise of integration between the different kind of analyses and the importance of keeping the consistency between the different assumptions and simplifications. The models used for the numerical analyses include a detailed geometrical description of the CB, the inlet, outlet hydraulic manifolds, the CB to vacuum vessel locking system and three configurations of the PFU. The effect of electrical bridging, both in poloidal and toroidal direction, of the PFU castellation, due to a possible melting at the W mono-block or tiles, occurring during the plasma disruptions, has been analyzed. For all these configurations 2 VDE scenarios including the effect of the Toroidal Field Variation and the HaloCurrent with the related out of plane induced EM forces have been extensively analyzed and a detailed poloidal and radial distribution of the nuclear heating has been used for the neutronic flux on the divertor components. The aim of this activity is to produce a comprehensive design and assessment of the ITER divertor via: -The estimation of the neutronic heat deposition and shielding capability; -The calculation of the related thermal and mechanical effects and the comparison of the

  13. On the refuelling of large divertor experiments

    International Nuclear Information System (INIS)

    Staebler, A.; Haas, G.; Ott, W.; Speth, E.

    1976-01-01

    The use of fast hydrogen atoms, molecules and clusters for refuelling large divertor-experiments like ASDEX is investigated. Three criteria for the choice among the various methods are discussed. It is shown that clusters suffer from lack of penetration. Molecules, created by fragmentation of clusters, offer the advantage of plasma-like energy combined with appreciable penetration. Large penetration and high ionization efficiency can only be achieved at energies for above the plasma temperature with H 0 -atoms of several tens of keV

  14. Mitigation of divertor heat loads by strike point sweeping in high power JET discharges

    Science.gov (United States)

    Silburn, S. A.; Matthews, G. F.; Challis, C. D.; Frigione, D.; Graves, J. P.; Mantsinen, M. J.; Belonohy, E.; Hobirk, J.; Iglesias, D.; Keeling, D. L.; King, D.; Kirov, K.; Lennholm, M.; Lomas, P. J.; Moradi, S.; Sips, A. C. C.; Tsalas, M.; Contributors, JET

    2017-12-01

    Deliberate periodic movement (sweeping) of the high heat flux divertor strike lines in tokamak plasmas can be used to manage the heat fluxes experienced by exhaust handling plasma facing components, by spreading the heat loads over a larger surface area. Sweeping has recently been adopted as a routine part of the main high performance plasma configurations used on JET, and has enabled pulses with 30 MW plasma heating power and 10 MW radiation to run for 5 s without overheating the divertor tiles. We present analysis of the effectiveness of sweeping for divertor temperature control on JET, using infrared camera data and comparison with a simple 2D heat diffusion model. Around 50% reduction in tile temperature rise is obtained with 5.4 cm sweeping compared to the un-swept case, and the temperature reduction is found to scale slower than linearly with sweeping amplitude in both experiments and modelling. Compatibility of sweeping with high fusion performance is demonstrated, and effects of sweeping on the edge-localised mode behaviour of the plasma are reported and discussed. The prospects of using sweeping in future JET experiments with up to 40 MW heating power are investigated using a model validated against existing experimental data.

  15. Mitigation of divertor heat loads by strike point sweeping in high power JET discharges

    International Nuclear Information System (INIS)

    Silburn, S A; Matthews, G F; Challis, C D; Belonohy, E; Iglesias, D; Keeling, D L; King, D; Kirov, K; Lomas, P J; Frigione, D; Graves, J P; Mantsinen, M J; Hobirk, J; Lennholm, M; Moradi, S; Sips, A C C; Tsalas, M

    2017-01-01

    Deliberate periodic movement (sweeping) of the high heat flux divertor strike lines in tokamak plasmas can be used to manage the heat fluxes experienced by exhaust handling plasma facing components, by spreading the heat loads over a larger surface area. Sweeping has recently been adopted as a routine part of the main high performance plasma configurations used on JET, and has enabled pulses with 30 MW plasma heating power and 10 MW radiation to run for 5 s without overheating the divertor tiles. We present analysis of the effectiveness of sweeping for divertor temperature control on JET, using infrared camera data and comparison with a simple 2D heat diffusion model. Around 50% reduction in tile temperature rise is obtained with 5.4 cm sweeping compared to the un-swept case, and the temperature reduction is found to scale slower than linearly with sweeping amplitude in both experiments and modelling. Compatibility of sweeping with high fusion performance is demonstrated, and effects of sweeping on the edge-localised mode behaviour of the plasma are reported and discussed. The prospects of using sweeping in future JET experiments with up to 40 MW heating power are investigated using a model validated against existing experimental data. (paper)

  16. Failure mode analysis of preliminary design of ITER divertor impurity monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki

    2016-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • Failure mode of DIM was prepared for RAMI analysis. • RAMI analysis on DIM was performed to reduce technical risks. - Abstract: The objective of the divertor impurity influx monitor (DIM) for ITER is to measure the parameters of impurities and hydrogen isotopes (tritium, deuterium, and hydrogen) in divertor plasma using visible and UV spectroscopic techniques in the 200–1000 nm wavelength range. In ITER, special provisions are required to ensure accuracy and full functionality of the diagnostic components under harsh conditions (high temperature, high magnetic field, high vacuum condition, and high radiation field). Japan Domestic Agency is preparing the preliminary design of the ITER DIM system, which will be installed in the upper, equatorial and lower ports. The optical and mechanical designs of the DIM are conducted to fit ITER’s requirements. The optical and mechanical designs meet the requirements of spatial resolution. Some auxiliary systems were examined via prototyping. The preliminary design of the ITER DIM system was evaluated by RAMI analysis. The availability of the designed system is adequately high to satisfy the project requirements. However, some equipment does not have certain designs, and this may cause potential technical risks. The preliminary design should be modified to reduce technical risks and to prepare the final design.

  17. Modelling of mitigation of the power divertor loading for the EU DEMO through Ar injection

    Science.gov (United States)

    Subba, Fabio; Aho-Mantila, Leena; Coster, David; Maddaluno, Giorgio; Nallo, Giuseppe F.; Sieglin, Bernard; Wenninger, Ronald; Zanino, Roberto

    2018-03-01

    In this paper we present a computational study on the divertor heat load mitigation through impurity injection for the EU DEMO. The study is performed by means of the SOLPS5.1 code. The power crossing the separatrix is considered fixed and corresponding to H-mode operation, whereas the machine operating condition is defined by the outboard mid-plane upstream electron density and the impurity level. The selected impurity for this study is Ar, based on its high radiation efficiency at SOL characteristic temperatures. We consider a conventional vertical target geometry for the EU DEMO and monitor target conditions for different operational points, considering as acceptability criteria the target electron temperature (≤5 eV to provide sufficiently low W sputtering rate) and the peak heat flux (below 5-10 MW m-2 to guarantee safe steady-state cooling conditions). Our simulations suggest that, neglecting the radiated power deposition on the plate, it is possible to satisfy the desired constraints. However, this requires an upstream density of the order of at least 50% of the Greenwald limit and a sufficiently high argon fraction. Furthermore, if the radiated power deposition is taken into account, the peak heat flux on the outer plate could not be reduced below 15 MW m-2 in these simulations. As these simulations do not take into account neutron loading, they strongly indicate that the vertical target divertor solution with a radiative front distributed along the divertor leg has a very marginal operational space in an EU DEMO sized reactor.

  18. A tangentially viewing VUV TV system for the DIII-D divertor

    International Nuclear Information System (INIS)

    Nilson, D.G.; Ellis, R.; Fenstermacher, M.E.; Brewis, G.; Jalufka, N.

    1998-07-01

    A video camera system capable of imaging VUV emission in the 120--160 nm wavelength range, from the entire divertor region in the DIII-D tokamak, was designed. The new system has a tangential view of the divertor similar to an existing tangential camera system which has produced two dimensional maps of visible line emission (400--800 nm) from deuterium and carbon in the divertor region. However, the overwhelming fraction of the power radiated by these elements is emitted by resonance transitions in the ultraviolet, namely the C IV line at 155.0 nm and Ly-α line at 121.6 nm. To image the ultraviolet light with an angular view including the inner wall and outer bias ring in DIII-D, a 6-element optical system (f/8.9) was designed using a combination of reflective and refractive optics. This system will provide a spatial resolution of 1.2 cm in the object plane. An intermediate UV image formed in a secondary vacuum is converted to the visible by means of a phosphor plate and detected with a conventional CID camera (30 ms framing rate). A single MgF 2 lens serves as the vacuum interface between the primary and secondary vacuums; a second lens must be inserted in the secondary vacuum to correct the focus at 155 nm. Using the same tomographic inversion method employed for the visible TV, they reconstruct the poloidal distribution of the UV divertor light. The grain size of the phosphor plate and the optical system aberrations limit the best focus spot size to 60 microm at the CID plane. The optical system is designed to withstand 350 C vessel bakeout, 2 T magnetic fields, and disruption-induced accelerations of the vessel

  19. Installation and initial operation of the DIII-D advanced divertor cryocondensation pump

    International Nuclear Information System (INIS)

    Smith, J.P.; Schaubel, K.M.; Baxi, C.B.; Campbell, G.L.; Hyatt, A.W.; Laughon, G.J.; Mahdavi, M.A.; Reis, E.E.; Schaffer, M.J.; Sevier, D.L.; Stambaugh, R.D.; Menon, M.M.

    1993-10-01

    Phase two of a divertor cryocondensation pump, the Advanced Divertor Program, is now installed in the DIII-D tokamak at General Atomics and complements the phase one biasable ring electrode. The installation consists of a 10 m long cryocondensation pump located in the divertor baffle chamber to study plasma density control by pumping of the divertor. The design is a toroidally electrically continuous liquid helium-cooled panel with 1 m 2 of pumping surface. The helium panel is single point grounded to the nitrogen shield to minimize eddy currents. The nitrogen shield is toroidally continuous and grounded to the vacuum vessel in 24 locations to prevent voltage potentials from building up between the pump and vacuum vessel wall. A radiation/particle shield surrounds the nitrogen-cooled surface to minimize the heat load and prevent water molecules condensed on the nitrogen surface from being released by impact of energetic particles. Large currents (>5000 A) are driven in the helium and nitrogen panels during ohmic coil ramp up and during disruptions. The pump is designed to accommodate both the thermal and mechanical loads due to these currents. A feedthrough for the cryogens allows for both radial and vertical motion of the pump with respect to the vacuum vessel. Thermal performance measured on a prototype verified the analytical model and thermal design of the pump. Characterization tests of the installed pump show the pumping speed in deuterium is 42,000 ell/sec for a pressure of 5 mTorr. Induction heating of the pump (at 300 W) resulted in no degradation of pumping speed. Plasma operations with the cryopump show a 60% lower density in H-mode

  20. Radiation induced defect flux behaviors at zirconium based component

    International Nuclear Information System (INIS)

    Choi, Sang Il; Kim, Ji Hyun; Kwon, Jun Hyun; Lee, Gyeong Geun

    2013-01-01

    In commercial reactor core, structure materials are located in high temperature and high pressure environment. Therefore, main concern of structure materials is corrosion and mechanical properties change than radiation effects on materials. However, radiation effects on materials become more important phenomena because research reactor condition is different from commercial reactor. The temperature is lower than 100 .deg. C and radiation dose is much higher than that of commercial reactor. Among the radiation effect on zirconium based metal, radiation induced growth (RIG), known as volume conservative distortion, is one of the most important phenomena. Recently, theoretical RIG modeling based on radiation damage theory (RDT) and balance equation are developed. However, these growth modeling have limited framework of single crystal and high temperature. To model theoretical RIG in research reactor, qualitative mechanism must be set up. Therefore, this paper intent is establishing defect flux mechanism of zirconium base metal in research reactor for RIG modeling. After than theoretical RIG work will be expanded to research reactor condition

  1. A Route to Chaotic Behavior of Single Neuron Exposed to External Electromagnetic Radiation.

    Science.gov (United States)

    Feng, Peihua; Wu, Ying; Zhang, Jiazhong

    2017-01-01

    Non-linear behaviors of a single neuron described by Fitzhugh-Nagumo (FHN) neuron model, with external electromagnetic radiation considered, is investigated. It is discovered that with external electromagnetic radiation in form of a cosine function, the mode selection of membrane potential occurs among periodic, quasi-periodic, and chaotic motions as increasing the frequency of external transmembrane current, which is selected as a sinusoidal function. When the frequency is small or large enough, periodic, and quasi-periodic motions are captured alternatively. Otherwise, when frequency is in interval 0.778 electromagnetic radiation. The frequency apparently plays a more important role in determining the system behavior.

  2. Evaluation of divertor conceptual designs for a fusion power plant

    International Nuclear Information System (INIS)

    Ferrari, M.; Giancarli, L.; Kleefeldt, K.; Nardi, C.; Roedig, M.; Reimann, J.; Salavy, J.F.

    2001-01-01

    In the frame of the preliminary study of plants suitable for the energy production from the fusion power, particular emphasis has been given on the divertor studies. Since a significant percentage of the power generated from the fusion process is absorbed in the divertor, the thermal efficiency of the power conversion cycle requires a high coolant outlet temperature of the divertor, leading to solutions that are different from those adopted for the present experimental fusion plants. Therefore, copper alloys having extremely high thermal conductivity, cannot be used as structural material for this kind of devices. The most suitable coolants to be used in the divertor are water, helium and liquid metals. A conceptual design study has been developed for each of these three fluids, with the aim to evaluate the maximum allowable thermal flux at the divertor target plate and the R and D requirements for each solution. While a water-cooled divertor can be designed with a limited R and D effort, the development of helium or liquid metal cooled divertors requires a more engaging R and D program

  3. Operation method for thermonuclear device and divertor for it

    International Nuclear Information System (INIS)

    Kotake, Michiko; Yoshioka, Ken; Fukumoto, Hideshi; Okazaki, Takashi; Kinoshita, Shigemi; Takeuchi, Kazuhiro.

    1992-01-01

    Divertor plates are disposed subsequently along with circumferential direction of a vacuum vessel in a region where magnetic fluxed generated from the divertor coils are injected toward a container wall. Each of the divertor plates is moved in a state that the injection position of the magnetic fluxes enter to the vacuum vessel is kept constant. Alternatively, each of the divertor plates is inclined at an angle facing the injection direction of plasma particle fluxes, or it is inclined so that the angle between the injection surface and the magnetic fluxes makes an acute angle. Since each of the divertor coils is moved in the state of keeping the injection position of the magnetic fluxes during firing of plasmas, in other words, with on change of the current of the divertor coils, the position of the magnetic fluxed is kept at a predetermined condition. Accordingly, charged particles are prevented from concentrating locally without causing eddy current in the coils and the vacuum vessel, which can contribute to the reduction of the wear of the divertor plates. (N.H.)

  4. Scaling behavior of circular colliders dominated by synchrotron radiation

    Science.gov (United States)

    Talman, Richard

    2015-08-01

    The scaling formulas in this paper — many of which involve approximation — apply primarily to electron colliders like CEPC or FCC-ee. The more abstract “radiation dominated” phrase in the title is intended to encourage use of the formulas — though admittedly less precisely — to proton colliders like SPPC, for which synchrotron radiation begins to dominate the design in spite of the large proton mass. Optimizing a facility having an electron-positron Higgs factory, followed decades later by a p, p collider in the same tunnel, is a formidable task. The CEPC design study constitutes an initial “constrained parameter” collider design. Here the constrained parameters include tunnel circumference, cell lengths, phase advance per cell, etc. This approach is valuable, if the constrained parameters are self-consistent and close to optimal. Jumping directly to detailed design makes it possible to develop reliable, objective cost estimates on a rapid time scale. A scaling law formulation is intended to contribute to a “ground-up” stage in the design of future circular colliders. In this more abstract approach, scaling formulas can be used to investigate ways in which the design can be better optimized. Equally important, by solving the lattice matching equations in closed form, as contrasted with running computer programs such as MAD, one can obtain better intuition concerning the fundamental parametric dependencies. The ground-up approach is made especially appropriate by the seemingly impossible task of simultaneous optimization of tunnel circumference for both electrons and protons. The fact that both colliders will be radiation dominated actually simplifies the simultaneous optimization task. All GeV scale electron accelerators are “synchrotron radiation dominated”, meaning that all beam distributions evolve within a fraction of a second to an equilibrium state in which “heating” due to radiation fluctuations is canceled by the “cooling” in

  5. Performance Evaluation of Phototransistors and their Behavior under Gamma Radiation Effects

    International Nuclear Information System (INIS)

    Nasr, A.; Aboshosha, A.; Ashour, M.

    2008-01-01

    This article focuses on the performance evaluation of phototransistors under dark and illumination conditions as well as the influence of ionizing radiation on the behavior of these detectors. We study the I-V characteristics, DC current gain; HFE, dark current, photocurrent, emitter and collector resistances, breakdown voltage and the device's early voltage. The obtained results are analyzed to show how the device's response changes when exposed to radiation of different doses. Based-on our practical results we conclude that the phototransistors are more sensitive to ionizing radiation. Moreover, this kind of devices can be used as ionizing radiation detectors

  6. A prediction model for the radiation safety management behavior of medical cyclotrons

    International Nuclear Information System (INIS)

    Jung, Ji Hye; Han, Eun Ok; Kim, Ssang Tae

    2008-01-01

    This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: step 1 is a production preparation step, step 2 is an RI production step, step 3 is a synthesis step, step 4 is a distribution step, step 5 is a quality control step, step 6 is a carriage container packing step, and step 7 is a transportation step. It was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipment' were the most difficult as 9 subjects (37.5%), and in the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was 3.46 ± 0.47 out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in radiation safety managements, general

  7. A prediction model for the radiation safety management behavior of medical cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Ji Hye; Han, Eun Ok [Daegu Health College, Daegu (Korea, Republic of); Kim, Ssang Tae [CareCamp Inc., Seoul (Korea, Republic of)

    2008-06-15

    This study attempted to provide reference materials for improving the behavior level in radiation safety managements by drawing a prediction model that affects the radiation safety management behavior because the radiation safety management of medical Cyclotrons, which can be used to produce radioisotopes, is an important factor that protects radiation caused diseases not only for radiological operators but average users. In addition, this study obtained follows results through the investigation applied from January 2 to January 30, 2008 for the radiation safety managers employed in 24 authorized organizations, which have already installed Cyclotrons, through applying a specific form of questionnaire in which the validity was guaranteed by reference study, site investigation, and focus discussion by related experts. The radiation safety management were configured as seven steps: step 1 is a production preparation step, step 2 is an RI production step, step 3 is a synthesis step, step 4 is a distribution step, step 5 is a quality control step, step 6 is a carriage container packing step, and step 7 is a transportation step. It was recognized that the distribution step was the most exposed as 15 subjects (62.5%), the items of 'the sanction and permission related works' and 'the guarantee of installation facilities and production equipment' were the most difficult as 9 subjects (37.5%), and in the trouble steps in such exposure, the item of 'the synthesis and distribution' steps were 4 times, respectively (30.8%). In the score of the behavior level in radiation safety managements, the minimum and maximum scores were 2.42 and 4.00, respectively, and the average score was 3.46 {+-} 0.47 out of 4. Prosperity and well-being programs in the behavior and job in radiation safety managements (r=0.529) represented a significant correlation statistically. In the drawing of a prediction model based on the factors that affected the behavior in

  8. Disruption characteristics in PDX with limiter and divertor discharges

    International Nuclear Information System (INIS)

    Couture, P.; McGuire, K.

    1986-09-01

    A comparison has been made between the characteristics of disruptions with limiter and divertor configurations in PDX. A large data base on disruptions has been collected over four years of machine operation, and a total of 15,000 discharges are contained in the data file. It was found that divertor discharges have less disruptions during ramp up and flattop of the plasma current. However, for divertor discharges a large number of fast, low current disruptions take place during the current ramp down. These disruptions are probably caused by the deformation of the plasma shape

  9. Characterization of the island divertor plasma of W7-AS stellarator in the deeply detached state with volume recombination

    International Nuclear Information System (INIS)

    Ramasubramanian, N.; Koenig, R.; Feng, Y.; Giannone, L.; Grigull, P.; Klinger, T.; McCormick, K.; Thomsen, H.; Wenzel, U.

    2004-01-01

    In the high-density H-mode of the Stellarator Wendelstein 7-AS, the plasma detaches from the island divertor targets when the line-averaged density exceeds a critical value. This quasi-stationary detachment is found to be partial and shows edge-localized, poloidally asymmetric radiation. The spectroscopic characteristics of the deeply detached plasma are reported, including evidence for volume recombination. The detached plasma radiates up to 90% of the absorbed power with larger contributions from the locations close to magnetic X-points outside the divertor region. The spectral analysis of the Balmer series indicate very high densities and low temperatures at the detached regions. The results of the spectral analysis underline the importance of three-dimensional modelling. An initial comparison is made with the latest results from EMC3-EIRENE modelling. (author)

  10. Development of divertor simulation research in the GAMMA 10/PDX tandem mirror

    International Nuclear Information System (INIS)

    Nakashima, Y.; Sakamoto, M.; Yoshikawa, M.; Oki, K.; Takeda, H.; Ichimura, K.; Hosoi, K.; Hirata, M.; Ichimura, M.; Ikezoe, R.; Imai, T.; Kariya, T.; Katanuma, I.; Kohagura, J.; Minami, R.; Numakura, T.; Wang, X.; Iwamoto, M.; Hosoda, Y.; Asakura, Nobuyuki; Fukumoto, Masakatsu; Kubo, Hirotaka; Hatayama, A.; Hirooka, Y.; Masuzaki, S.; Sagara, A.; Shoji, M.; Kado, S.; Matsuura, H.; Nagata, S.; Shikama, T.; Nishino, N.; Ohno, N.; Tonegawa, A.; Ueda, Y.

    2014-10-01

    This paper describes the recent development of divertor simulation research towards the characterization and control of the detached plasma. In the end-mirror of large tandem mirror device GAMMA 10/PDX, additional ICRF heating experiments in the anchor-cells significantly increases the density in both the anchor and the central cells, which attained the highest particle flux up to 1.7×10 23 particles/s·m 2 at the end-mirror exit. Massive gas injection (H 2 and noble gases) to enhance the radiation cooling in divertor simulation experimental module (D-module) was performed and we have succeeded for the first time in achieving detachment of high temperature plasma equivalent to the SOL plasma of tokamaks by using linear device. A remarkable reduction of the electron temperature (from few tens eV to < 3 eV) on the target plate was successfully achieved associated with the strong reduction of particle and heat fluxes. Two-dimensional image of Hα emission in D-module observed with high-speed camera showed the bright emission in upstream region and strong reduction near the target plate. These results indicate radiation cooling and formation of detached plasma due to gas injection. It is also found that Xe gas is much effective on achieving detached plasma than Ar gas. Simultaneous injection of noble gas and hydrogen gas showed the most effective results on detached plasma generation, which indicates the effect of molecular activated recombination (MAR) processes. The above results will contribute to establishment of detached plasma control and clarification of radiation cooling mechanism towards the development of future divertor systems. (author)

  11. The role of ''momentum removal'' in divertor detachment

    Energy Technology Data Exchange (ETDEWEB)

    Kukushkin, A.S. [Kurchatov Institute, Moscow (Russian Federation); NRNU MEPhI, Moscow (Russian Federation); Pacher, H.D. [INRS-EMT, Varennes, Quebec (Canada)

    2016-08-15

    The role of ''momentum removal'' (the drag force on the plasma ion flow) in divertor detachment is considered and analysed in detail. This analysis of the 2D modelling results shows that the drag force cannot reduce the power and particle flux to the target directly. However, it is essential for creating the conditions for efficient radiation and volumetric plasma recombination, which in turn do the job. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. The ergodic divertor a way to prevent major disruptions

    International Nuclear Information System (INIS)

    Vallet, J.C.; Poutchy, L.; Mohamed-Benkadda, M.S.; Edery, D.; Joffrin, E.; Lecoustey, P.; Pecquet, A.L.; Samain, A.; Talvard, M.

    1991-01-01

    The disruptions are one of the major obstacles to present day tokamaks extrapolation to fusion reactors. We have recently proposed a piloting discharge strategy on TORE SUPRA to prevent density limit disruptions. This strategy is based on the use of the Ergodic Divertor (ED). We have observed that the ED stabilizes the m=2 n=1 tearing mode and that in deuterium discharges limited by the outboard limiter it induces a fast decrease of the plasma density. The piloting strategy is taken in three steps: 1) the approach of the density limit is detected by a threshold on the MHD activity amplitude; 2) the gas puff is switched off; 3) the ED is turned on. Then the m=2 n=1 tearing mode is stabilized the density decreases and the disruption is avoided. This strategy has already been successully tested on about 20 specific deuterium shots with 2.5< q(a)<4.5 in which the density limit is approached by ramping up the density with gas puffing. In this paper, experimental data are reported and analyzed. First, the principle of the ED and the density limit disruption phenomenology are briefly recalled. Then the ED effect on plasma density, radiated power and MHD activity are analyzed, and the piloting strategy to prevent density limit disruptions is discussed

  13. Heat and particle transport of sol/divertor plasma in the W-shaped divertor on JT-60U

    International Nuclear Information System (INIS)

    Asakura, N.; Sakurai, S.; Hosogane, N.

    1999-01-01

    The plasma profile and parallel flow in the scrape-off layer (SOL) were systematically measured using Mach probes installed at the midplane and the divertor x-point. Quantitative evaluation of a parallel flow: naturally produced in a torus to keep the pressure constant along the field line, was consistent with the measurement. Geometry effects of the W-shaped divertor on the divertor plasma and particle recycling at the newly installed baffle plates were evaluated quantitatively using the edge plasma data. (author)

  14. Radiation Safety Management Guidelines for PET-CT: Focus on Behavior and Environment

    International Nuclear Information System (INIS)

    Jung, Jin Wook; Han, Eun Ok

    2011-01-01

    Our purpose is to specify behavior and environmental factors aimed at reducing the exposed dosage caused by PET-CT and to develop radiation safety management guidelines adequate for domestic circumstances. We have used a multistep-multimethod as the methodological approach to design and to carry out the research both in quality and quantity, including an analysis on previous studies, professional consultations and a survey. The survey includes responses from 139 practitioners in charged of 109 PET-CTs installed throughout Korea(reported by the Korean Society of Nuclear Medicine, 2010). The research use 156 questions using Cronbach's α (alpha) coefficients which were: 0.818 for 'the necessity of setting and installing the radiation protective environment'; 0.916 for 'the necessity of radiation protection', 'setting and installing the radiation protective environment'; and 0.885 for 'radiation protection'. The check list, derived from the radiation safety management guidelines focused on behavior and environment, was composed of 20 items for the radiation protective environment: including 5 items for the patient; 4 items for the guardian; 3 items for the radiologist; and 8 items applied to everyone involved; for a total of 26 items for the radiation protective behavior including: 12 items for the patient; 1 item for the guardian, 7 items for the radiologist; and 6 items applied to everyone involved. The specific check list is shown in (Table 5-6). Since our country has no safety management guidelines of its own to reduce the exposed dosage caused by PET-CTs, we believe the guidelines developed through this study means great deal to the field as it is not only appropriate for domestic circumstances, but also contains specific check lists for each target who may be exposed to radiation in regards to behavior and environment.

  15. Brain signaling and behavioral responses induced by exposure to (56)Fe-particle radiation

    Science.gov (United States)

    Denisova, N. A.; Shukitt-Hale, B.; Rabin, B. M.; Joseph, J. A.

    2002-01-01

    Previous experiments have demonstrated that exposure to 56Fe-particle irradiation (1.5 Gy, 1 GeV) produced aging-like accelerations in neuronal and behavioral deficits. Astronauts on long-term space flights will be exposed to similar heavy-particle radiations that might have similar deleterious effects on neuronal signaling and cognitive behavior. Therefore, the present study evaluated whether radiation-induced spatial learning and memory behavioral deficits are associated with region-specific brain signaling deficits by measuring signaling molecules previously found to be essential for behavior [pre-synaptic vesicle proteins, synaptobrevin and synaptophysin, and protein kinases, calcium-dependent PRKCs (also known as PKCs) and PRKA (PRKA RIIbeta)]. The results demonstrated a significant radiation-induced increase in reference memory errors. The increases in reference memory errors were significantly negatively correlated with striatal synaptobrevin and frontal cortical synaptophysin expression. Both synaptophysin and synaptobrevin are synaptic vesicle proteins that are important in cognition. Striatal PRKA, a memory signaling molecule, was also significantly negatively correlated with reference memory errors. Overall, our findings suggest that radiation-induced pre-synaptic facilitation may contribute to some previously reported radiation-induced decrease in striatal dopamine release and for the disruption of the central dopaminergic system integrity and dopamine-mediated behavior.

  16. Resonant island divertor experiments on text

    International Nuclear Information System (INIS)

    deGrassie, J.S.; Evans, T.E.; Jackson, G.L.

    1988-09-01

    The first experimental tests of the resonant island divertor (RID) concept have been carried out on the Texas Experimental Tokamak (TEXT). Modular perturbation coils produce static resonant magnetic fields at the tokamak boundary. The resulting magnetic islands are used to guide heat and particle fluxes around a small scoop limiter head. An enhancement in the limiter collection efficiency over the nonisland operation, as evidenced by enhanced neutral density within the limiter head, of up to a factor of 4 is obtained. This enhancement is larger than one would expect given the measured magnitude of the cross-field particle transport in TEXT. It is proposed that electrostatic perturbations occur which enhance the ion convection rate around the islands. Preliminary experiments utilizing electron cyclotron heating (ECH) in conjunction with RID operation have also have been performed. 6 refs., 3 figs

  17. ELM induced divertor heat loads on TCV

    Science.gov (United States)

    Marki, J.; Pitts, R. A.; Horacek, J.; Tskhakaya, D.; TCV Team

    2009-06-01

    Results are presented for heat loads at the TCV outer divertor target during ELMing H-mode using a fast IR camera. Benefitting from a recent surface cleaning of the entire first wall graphite armour, a comparison of the transient thermal response of freshly cleaned and untreated tile surfaces (coated with thick co-deposited layers) has been performed. The latter routinely exhibit temperature transients exceeding those of the clean ones by a factor ˜3, even if co-deposition throughout the first days of operation following the cleaning process leads to the steady regrowth of thin layers. Filaments are occasionally observed during the ELM heat flux rise phase, showing a spatial structure consistent with energy release at discrete toroidal locations in the outer midplane vicinity and with individual filaments carrying ˜1% of the total ELM energy. The temporal waveform of the ELM heat load is found to be in good agreement with the collisionless free streaming particle model.

  18. ELM induced divertor heat loads on TCV

    Energy Technology Data Exchange (ETDEWEB)

    Marki, J., E-mail: janos.marki@epfl.c [Centre de Recherches en Physique des Plasmas (CRPP), Ecole Polytechnique Federale de Lausanne (EPFL), Association Euratom - Confederation Suisse, CH-1015 Lausanne (Switzerland); Pitts, R.A. [Centre de Recherches en Physique des Plasmas (CRPP), Ecole Polytechnique Federale de Lausanne (EPFL), Association Euratom - Confederation Suisse, CH-1015 Lausanne (Switzerland); Horacek, J. [Institute of Plasma Physics, Association EUROATOM-IPP.CR, Za Slovankou 3, 182 00 Prague 8 (Czech Republic); Tskhakaya, D. [Association EURATOM-OAW, Institut fuer Theoretische Physik, A-6020 Innsbruck (Austria)

    2009-06-15

    Results are presented for heat loads at the TCV outer divertor target during ELMing H-mode using a fast IR camera. Benefitting from a recent surface cleaning of the entire first wall graphite armour, a comparison of the transient thermal response of freshly cleaned and untreated tile surfaces (coated with thick co-deposited layers) has been performed. The latter routinely exhibit temperature transients exceeding those of the clean ones by a factor approx3, even if co-deposition throughout the first days of operation following the cleaning process leads to the steady regrowth of thin layers. Filaments are occasionally observed during the ELM heat flux rise phase, showing a spatial structure consistent with energy release at discrete toroidal locations in the outer midplane vicinity and with individual filaments carrying approx1% of the total ELM energy. The temporal waveform of the ELM heat load is found to be in good agreement with the collisionless free streaming particle model.

  19. Cryopump behavior in the presence of beam or nuclear radiation

    International Nuclear Information System (INIS)

    Law, P.K.

    1977-12-01

    Cryocondensation pumping has been proposed to be the method of gas removal for neutral-beam refueled fusion reactors. A cryocondensation pumping unit has been constructed to test design concepts and compatibility with conditions under actual beam operation and nuclear radiation environment. Various operating parameters for this test pumping unit have been measured, including pumping speeds for various gases and beam desorption effects. An experiment has been planned at the Berkeley Research Reactor to measure the desorption effects of high energy neutrons and gamma radiation. A foil activation method has been devised to accurately assess the energy spectrum of this neutron source, which is expected to be comparable to that of the Tokamak Fusion Test Reactor

  20. Optical emission behavior and radiation resistance of epoxy resins

    International Nuclear Information System (INIS)

    Kawanishi, Shunichi; Udagawa, Akira; Hagiwara, Miyuki

    1987-11-01

    To make clear a mechanism of radiation resistance of epoxy resin systems, a role of energy trapping site induced in bisphenol A type epoxy resins cured with 4 kinds of aromatic amines (Φ N ) was studied in comparison with the case of aliphatic amine curing system through a measurement of optical emission. In the system of the epoxy resin cured with DETA, the optical emission from an excited state of bisphenol A unit of epoxy resin and a charge transfer complex was observed. On the other hand, the optical emission from Φ N was observed in the aromatic amine curing system. Their excitation spectrum consists of peaks of absorption spectrum of BA and those of Φ N , showing that the excited state of Φ N is formed through the excitation of both BA and Φ N . Therefore, the excited energy of BA transfers to the excited state of Φ N . Emission intensity of Φ N band was 20 ∼ 100 times as large as that of BA. These results indicate that the radiation energy is effectively released as an optical emission from excited state of Φ N in the epoxy resin when cured with aromatic amine. It can be concluded from the above results that aromatic amine hardeners contribute to enhancement of the radiation resistance of epoxy resin by acting as an energy transfer agent. (author)

  1. Desulfurization of petroleum induced by ionization radiation: benzothiophene behavior

    International Nuclear Information System (INIS)

    Andrade, Luana S.; Calvo, Wilson A.P.; Duarte, Celina L.

    2013-01-01

    Hydrodesulfurization (HDS) is currently the most common method used by refineries; this removes significantly sulfur compounds from petroleum fractions, however, is not highly effective for removing thiophene compounds such as benzothiophene, and generates high costs for the oil industry. Another factor, are the environmental laws, which over the years has become increasingly strict, especially regarding the sulfur content. This compound cause incalculable damage both to the industry and to the environment. Therefore new methods for petroleum desulfurization should be studied in order to minimize the impacts that these compounds cause. In the present study it was used ionizing radiation, a promising method of advanced oxidation in reducing sulfur compounds. The analysis were performed after purge and trap concentration of samples, followed by gas chromatography-mass spectrometry (GC-MS). Then benzothiophene samples with the same concentration from 27 mg.L -1 to 139 mg.L -1 were irradiated with different absorbed doses of radiation ranging from 1 kGy to 20 kGy in gamma irradiator Cobalt-60, Gammacell. These samples were analyzed by the same procedure used for the calibration curve, and the removals of benzothiophene after ionizing radiation treatment were calculated. It was observed that at higher doses there was a greater degradation of this compound and the formation of fragments, such as 1,2-dimethylbenzene and toluene, which may be removed by simple processes. (author)

  2. Apolipoprotein E expression and behavioral toxicity of high charge, high energy (HZE) particle radiation

    Science.gov (United States)

    Higuchi, Yoshinori; Nelson, Gregory A.; Vazquez, Marcelo; Laskowitz, Daniel T.; Slater, James M.; Pearlstein, Robert D.

    2002-01-01

    Apolipoprotein E (apoE) is a lipid binding protein that plays an important role in tissue repair following brain injury. In the present studies, we have investigated whether apoE affects the behavioral toxicity of high charge, high energy (HZE) particle radiation. METHODS: Sixteen male apoE knockout (KO) mice and sixteen genetically matched wild-type (WT) C57BL mice were used in this experiment. Half of the KO and half of the WT animals were irradiated with 600 MeV/amu iron particles (2 Gy whole body). The effect of irradiation on motor coordination and stamina (Rotarod test), exploratory behavior (open field test), and spatial working and reference memory (Morris water maze) was assessed. ROTAROD TEST: Performance was adversely affected by radiation exposure in both KO and WT groups at 30 d after irradiation. By 60 d after radiation, the radiation effect was lost in WT, but still apparent in irradiated KO mice. OPEN FIELD TEST: Radiation reduced open field exploratory activity 14, 28, 56, 84, and 168 d after irradiation of KO mice, but had no effect on WT mice. MORRIS WATER MAZE: Radiation adversely affected spatial working memory in the KO mice, but had no discernible effect in the WT mice as assessed 180 d after irradiation. In contrast, irradiated WT mice showed marked impairment of spatial reference memory in comparison to non-irradiated mice, while no effect of radiation was observed in KO mice. CONCLUSIONS: These studies show that apoE expression influences the behavioral toxicity of HZE particle radiation and suggest that apoE plays a role in the repair/recovery from radiation injury of the CNS. ApoE deficiency may exacerbate the previously reported effects of HZE particle radiation in accelerating the brain aging process.

  3. Apolipoprotein E expression and behavioral toxicity of high charge, high energy (HZE) particle radiation

    International Nuclear Information System (INIS)

    Higuchi, Yoshinori; Nelson, G.A.; Slater, J.M.; Pearlstein, R.D.; Laskowitz, D.T.

    2002-01-01

    Apolipoprotein E (apoE) is a lipid binding protein that plays an important role in tissue repair following brain injury. In the present studies, we have investigated whether apoE affects the behavioral toxicity of high charge, high energy (HZE) particle radiation. Sixteen male apoE knockout (KO) mice and sixteen genetically matched wild-type (WT) C57BL mice were used in this experiment. Half of the KO and half of the WT animals were irradiated with 600 MeV/amu iron particles (2 Gy whole body). The effect of irradiation on motor coordination and stamina (Rotarod test), exploratory behavior (open field test), and spatial working and reference memory (Morris water maze) was assessed. Rotarod test: Performance was adversely affected by radiation exposure in both KO and WT groups at 30 d after irradiation. By 60 d after radiation, the radiation effect was lost in WT, but still apparent in irradiated KO mice. Open field test: Radiation reduced open field exploratory activity 14, 28, 56, 84, and 168 d after irradiation of KO mice, but had no effect on WT mice. Morris water maze: Radiation adversely affected spatial working memory in the KO mice, but had no discernible effect in the WT mice as assessed 180 d after irradiation. In contrast, irradiated WT mice showed marked impairment of spatial reference memory in comparison to non-irradiated mice, while no effect of radiation was observed in KO mice. These studies show that apoE expression influences the behavioral toxicity of HZE particle radiation and suggest that apoE plays a role in the repair/recovery from radiation injury of the central nervous system (CNS). ApoE deficiency may exacerbate the previously reported effects of HZE particle radiation in accelerating the brain aging process. (author)

  4. Apolipoprotein E expression and behavioral toxicity of high charge, high energy (HZE) particle radiation

    Energy Technology Data Exchange (ETDEWEB)

    Higuchi, Yoshinori; Nelson, G.A.; Slater, J.M.; Pearlstein, R.D. [Loma Linda Univ., CA (United States). Medical Center; Vazquez, M. [Brookhaven National Lab., Upton, NY (United States); Laskowitz, D.T. [Duke Univ., Durham, NC (United States). Medical Center

    2002-12-01

    Apolipoprotein E (apoE) is a lipid binding protein that plays an important role in tissue repair following brain injury. In the present studies, we have investigated whether apoE affects the behavioral toxicity of high charge, high energy (HZE) particle radiation. Sixteen male apoE knockout (KO) mice and sixteen genetically matched wild-type (WT) C57BL mice were used in this experiment. Half of the KO and half of the WT animals were irradiated with 600 MeV/amu iron particles (2 Gy whole body). The effect of irradiation on motor coordination and stamina (Rotarod test), exploratory behavior (open field test), and spatial working and reference memory (Morris water maze) was assessed. Rotarod test: Performance was adversely affected by radiation exposure in both KO and WT groups at 30 d after irradiation. By 60 d after radiation, the radiation effect was lost in WT, but still apparent in irradiated KO mice. Open field test: Radiation reduced open field exploratory activity 14, 28, 56, 84, and 168 d after irradiation of KO mice, but had no effect on WT mice. Morris water maze: Radiation adversely affected spatial working memory in the KO mice, but had no discernible effect in the WT mice as assessed 180 d after irradiation. In contrast, irradiated WT mice showed marked impairment of spatial reference memory in comparison to non-irradiated mice, while no effect of radiation was observed in KO mice. These studies show that apoE expression influences the behavioral toxicity of HZE particle radiation and suggest that apoE plays a role in the repair/recovery from radiation injury of the central nervous system (CNS). ApoE deficiency may exacerbate the previously reported effects of HZE particle radiation in accelerating the brain aging process. (author)

  5. Evaluation of helium cooling for fusion divertors

    International Nuclear Information System (INIS)

    Baxi, C.B.

    1993-09-01

    The divertors of future fusion reactors will have a power throughput of several hundred MW. The peak heat flux on the diverter surface is estimated to be 5 to 15 MW/m 2 at an average heat flux of 2 MW/m 2 . The divertors have a requirement of both minimum temperature (100 degrees C) and maximum temperature. The minimum temperature is dictated by the requirement to reduce the absorption of plasma, and the maximum temperature is determined by the thermo-mechanical properties of the plasma facing materials. Coolants that have been considered for fusion reactors are water, liquid metals and helium. Helium cooling has been shown to be very attractive from safety and other considerations. Helium is chemically and neutronically inert and is suitable for power conversion. The challenges associated with helium cooling are: (1) Manifold sizes; (2) Pumping power; and (3) Leak prevention. In this paper the first two of the above design issues are addressed. A variety of heat transfer enhancement techniques are considered to demonstrate that the manifold sizes and the pumping power can be reduced to acceptable levels. A helium-cooled diverter module was designed and fabricated by GA for steady-state heat flux of 10 MW/m 2 . This module was recently tested at Sandia National Laboratories. At an inlet pressure of 4 MPa, the module was tested at a steady-state heat flux of 10 MW/m 2 . The pumping power required was less than 1% of the power removed. These results verified the design prediction

  6. Transport and divertor studies in the FM-1 spherator

    International Nuclear Information System (INIS)

    Ando, K.; Ejima, S.; Davis, S.; Hawryluk, R.; Hsuan, H.; Meade, D.; Okabayaski, M.; Sauthoff, N.; Schmidt, J.; Sinnis, J.

    1974-10-01

    Fundamental problems of toroidal fusion devices have been investigated in the FM-1 Spherator. These subjects include the transport due to drift wave turbulence in the trapped electron regime, poloidal divertor and impurities, and lower hybrid heating. (auth)

  7. Status of National Spherical Torus Experiment Liquid Lithium Divertor

    Science.gov (United States)

    Kugel, H. W.; Viola, M.; Ellis, R.; Bell, M.; Gerhardt, S.; Kaita, R.; Kallman, J.; Majeski, R.; Mansfield, D.; Roquemore, A. L.; Schneider, H.; Timberlake, J.; Zakharov, L.; Nygren, R. E.; Allain, J. P.; Maingi, R.; Soukhanovskii, V.

    2009-11-01

    Recent NSTX high power divertor experiments have shown significant and recurring benefits of solid lithium coatings on plasma facing components to the performance of divertor plasmas in both L- and H- mode confinement regimes heated by high-power neutral beams. The next step in this work is the 2009 installation of a Liquid Lithium Divertor (LLD). The 20 cm wide LLD located on the lower outer divertor, consists of four, 80 degree sections; each section is separated by a row of graphite diagnostic tiles. The temperature controlled LLD structure consists of a 0.01cm layer of vacuum flame-sprayed, 50 percent porous molybdenum, on top of 0.02 cm, 316-SS brazed to a 1.9 cm Cu base. The physics design of the LLD encompasses the desired plasma requirements, the experimental capabilities and conditions, power handling, radial location, pumping capability, operating temperature, lithium filling, MHD forces, and diagnostics for control and characterization.

  8. Two-dimensional divertor modeling and scaling laws

    International Nuclear Information System (INIS)

    Catto, P.J.; Connor, J.W.; Knoll, D.A.

    1996-01-01

    Two-dimensional numerical models of divertors contain large numbers of dimensionless parameters that must be varied to investigate all operating regimes of interest. To simplify the task and gain insight into divertor operation, we employ similarity techniques to investigate whether model systems of equations plus boundary conditions in the steady state admit scaling transformations that lead to useful divertor similarity scaling laws. A short mean free path neutral-plasma model of the divertor region below the x-point is adopted in which all perpendicular transport is due to the neutrals. We illustrate how the results can be used to benchmark large computer simulations by employing a modified version of UEDGE which contains a neutral fluid model. (orig.)

  9. Electron beam irradiation experiments of monoblock divertor mock-up

    International Nuclear Information System (INIS)

    Satoh, Kazuyoshi; Akiba, Masato; Araki, Masanori; Suzuki, Satoshi; Yokoyama, Kenji; Smid, I.; Cardella, A.; Duwe, R.; Di Pietro, E.

    1993-03-01

    It is one of the key issues for ITER to develop the divertor plate. Electron beam irradiation tests were carried out on a NET divertor mock-up using JEBIS at JAERI under a collaboration between The NET team, JAERI and KFA Juelich. Screening tests (maximum heat flux of 23 MW/m 2 ) and thermal cycling tests (18 MW/m 2 , 30s, 1000cycle) were carried out. As a result of the screening tests, the erosion caused by sublimation of C/C was observed on the surface of armor tile. No serious damage such as cracks or detachments, however, were found. As a result of the thermal cycling tests, no major damage was detected on the C/C surface. However cooling time constant of the divertor mock-up increased over 600cycle. Therefore it implies that some defects would occur at the brazing interface of the divertor mock-up. (author)

  10. Divertor pumping system with NBI cryopump for JT-60

    International Nuclear Information System (INIS)

    Akino, Noboru; Kuriyama, Masaaki; Ohga, Tokumichi; Seki, Hiroshi; Tanai, Yutaka

    1998-08-01

    The pumping system for JT-60 W-shape divertor with the NBI cryopump have been developed. The pumping speed achieved in the divertor region was 13-15 m 3 /s for deuterium gas with three units of the NBI cryopumps. In a simulation experiment of helium ash exhaust through the divertor, pumping of a mixed gas of helium and deuterium has been demonstrated using the NBI cryosorption pumps covered with an argon condensed layer. Control of neutral particle pressure in the divertor region became possible by having remodeled an aperture of the existing fast shutter, which is installed between the JT-60 vacuum vessel and NBI beam-line, to be regulated. (author)

  11. Development of liquid lithium divertor for fusion reactor

    International Nuclear Information System (INIS)

    Evtihkin, V. A.; Lyublinskij, I. E.; Vertkov, A.V.; Chumanov, A.V.; Shpolyanskij, V.N.

    2000-01-01

    Development of divertor is one of the most acute problems of the tokamak fusion reactor. The use of such materials as tungsten, beryllium, graphite and CFC's enabled to solve the problem to a certain extent fulfilling the need of the ITER project. The problem still rests unsolved for the DEMO-type reactors. Lithium if used as a material for high heat flux components may provide a successful solution of the problem. A concept of Li divertor based on the use of capillary-pore structures (CPS) is proposed and is being validated by a complex of experimental research and engineering developments. An optional concept of Li divertor for power removal at 400 MW in steady-state (DEMO-S project) is presented. The complex of experimental research is under way to prove the serviceability of the Li CPS in different conditions that would be realized in divertor

  12. Divertor IR thermography on Alcator C-Moda)

    Science.gov (United States)

    Terry, J. L.; LaBombard, B.; Brunner, D.; Payne, J.; Wurden, G. A.

    2010-10-01

    Alcator C-Mod is a particularly challenging environment for thermography. It presents issues that will similarly face ITER, including low-emissivity metal targets, low-Z surface films, and closed divertor geometry. In order to make measurements of the incident divertor heat flux using IR thermography, the C-Mod divertor has been modified and instrumented. A 6° toroidal sector has been given a 2° toroidal ramp in order to eliminate magnetic field-line shadowing by imperfectly aligned divertor tiles. This sector is viewed from above by a toroidally displaced IR camera and is instrumented with thermocouples and calorimeters. The camera provides time histories of surface temperatures that are used to compute incident heat-flux profiles. The camera sensitivity is calibrated in situ using the embedded thermocouples, thus correcting for changes and nonuniformities in surface emissivity due to surface coatings.

  13. Design, fabrication, and testing of a helium-cooled module for the ITER divertor

    International Nuclear Information System (INIS)

    Baxi, C.B.; Smith, J.P.; Youchison, D.

    1994-08-01

    The International Thermonuclear Reactor (ITER) will have a single-null divertor with total power flow of 200 MW and a peak heat flux of about 5 MW/m 2 . The reference coolant for the divertor is water. However, helium is a viable alternative and offers advantages from safety considerations, such as excellent radiation stability and chemical inertness. In order to prove the feasibility of helium cooling at ITER relevant heat flux conditions, General Atomics designed, fabricated, and tested a helium-cooled divertor module. The module was made from dispersion strengthened copper, with a heat flux surface 25 mm wide and 80 mm long, designed for twice the ITER divertor heat flux. Different techniques were examined to enhance the heat transfer, which in turn reduced the flow and pumping power required to cool the module. It was concluded that an extended surface was the most practical solution. An optimization study was performed to find the best extended surface parameters. The optimum extended surface geometry consisted of fins: 10 mm high, 0.4 mm thick with a 1 mm pitch. It was estimated to require a pumping power of 150 W to remove 20 kW of power. This is more than an order of magnitude reduction in pumping power requirement, compared to smooth surface. The module was fabricated by electric discharge machining (EDM) process. The testing was carried out at SNLA during August 1993. The testing confirmed the design calculations. The peak heat flux during the test was 10 MW/m 2 applied over a surface area of 20 cm 2 . The pumping power calculated from flow rate and pressure drop measurement was about 160 W, which was less than 1% of the power removed. It is planned to test the module to higher temperature limits and higher heat fluxes during coming months. As a result of this effort we conclude that helium cooling of the ITER divertor is feasible without requiring a very large helium pressure or a large pumping power

  14. Research and development of remote maintenance equipment for ITER divertor maintenance

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Kakudate, Satoshi; Nakahira, Masataka

    2005-02-01

    To facilitate easy remote maintainability, the ITER divertor is divided into 60 cassettes, which are transported in the toroidal and radial directions for replacement through maintenance ports located every 90 degrees using the divertor remote maintenance equipment such as in- and ex-vessel transporters. The cassette of 25 tons has to be transported and installed in the vacuum vessel with a positioning accuracy less than 2 mm in the limited space of the vacuum vessel and maintenance port under the intense gamma radiation field. Based on these requirements, the following design and tests were performed. (1) Link mechanism was studied to apply to the transportation of the heavy cassette in the restricted space. A compact mechanism with links for transportation of heavy cassette is designed through the optimization of the link angle taking account of space requirement and force efficiency. As a test result, the lifting capacity of 30 tons (larger than the cassette weight of 25 tons) using two link mechanisms has been demonstrated in the limited space. (2) Compact link mechanism was also studied to apply for locking of the cassette through the optimization of the link angle taking account of space requirement and force efficiency. As a test result, the final positioning accuracy of 0.03 mm for the 25 tons-cassette installation on the vacuum vessel from the initial positioning error of 5 mm has been demonstrated, so that the test result satisfies the requirement less than 2 mm using the link mechanisms in the limited space. (3) Sensor-based control using simple sensors such as optical fiber for divertor maintenance was tested using the full-scale mock-up divertor cassette and remote maintenance equipment. As a result, it is found that the positioning accuracy of 0.16 mm has been achieved by the optical fiber sensor and this value is sufficient for sensor-based control. In addition, the maintenance operation has been carried out through the human-machine interface

  15. Fabrication of divertor mock-up with ODS-Cu and W by the improved brazing technique

    Science.gov (United States)

    Tokitani, M.; Hamaji, Y.; Hiraoka, Y.; Masuzaki, S.; Tamura, H.; Noto, H.; Tanaka, T.; Muroga, T.; Sagara, A.; FFHR Design Group

    2017-07-01

    Copper alloy has been considered as a divertor cooling tube or heat sink not only in the helical reactor FFHR-d1 but also in the tokamak DEMO reactor, because it has a high thermal conductivity. This work focused on applying an oxide dispersion strengthened copper alloy (ODS-Cu), GlidCop® (Cu-0.3 wt%Al2O3) as the divertor heat sink material of FFHR-d1. This alloy has superior high temperature yield strength exceeding 300 MPa at room temperature even after annealing up to ~1000 °C. The change in material properties of Pure-Cu, GlidCop® and CuCrZr by neutron irradiation are summarized in this paper. A primary dose limit is the radiation-induced hardening/softening (~0.2 dpa/1-2 dpa) which has a temperature dependence. According to such an evaluation, the GlidCop® can be selected as the current best candidate material in the commercial base of the divertor heat sink, and its temperature should be maintained as close as possible to 300 °C during operation. Bonding between the W armour and the GlidCop® heat sink was successfully performed by using an improved brazing technique with BNi-6 (Ni-11%P) filler material. The bonding strength was measured by a three-point bending test and reached up to approximately 200 MPa. Surprisingly, several specimens showed an obvious yield point. This means that the BNi-6 brazing (bonding) layer caused relaxation of the applied stress. The small-scale divertor mock-up of the W/BNi-6/GlidCop® was successfully fabricated by using the improved brazing technique. The heat loading test was carried out by the electron beam device ACT2 in NIFS. The mock-up showed an excellent heat removal capability for use in the FFHR-d1 divertor.

  16. Thermomechanical simulation of WEST actively cooled upper divertor

    International Nuclear Information System (INIS)

    Batal, T.; Richou, M.; Guilhem, D.; Firdaouss, M.; Larroque, S.; Ferlay, F.; Missirlian, M.; Bucalossi, J.

    2016-01-01

    The Tore Supra tokamak is being transformed in an x-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support to the ITER tungsten divertor strategy. The WEST project aims to test ITER-like W monoblock Plasma Facing Units (PFU). This ITER-like divertor will be tested under long plasma discharge up to 1000 s, with high heat flux density up to 20 MW/m 2 . This paper presents the results of ANSYS thermal-structural simulations of the WEST upper divertor. The upper divertor is made of twelve 30° sectors, each one composed of 38 PFU. The PFUs are actively cooled CuCrZr heat sinks and the incidence surface is coated with a thin tungsten layer. The fixing system is made of pins engaged in slotted holes. Besides, the fixing system of the sector assembly is the same as WEST lower divertor, so one upper divertor sector can be used indifferently in upper or Lower position during transitional operation phases in WEST. The total surface of the upper divertor is 8 m 2 , and it has to be able to extract up to 4 MW in steady-state, with peak heat flux values up to 8 MW/m 2 . The fixing system was designed to handle structural loads such as forces and torques resulting from halo and eddy current, respectively, especially during disruptions and Vertical Displacement Event (VDE). The torque resulting from eddy current is first calculated thanks to an internal CEA ANSYS APDL routine. Then the ANSYS structural and thermal-structural simulations of the PFU are presented, and its design is validated thanks to A-level RCC-MRx criteria. Finally, the most conservative load case is determined in order to validate the design of the pins and the support structure.

  17. Thermomechanical simulation of WEST actively cooled upper divertor

    Energy Technology Data Exchange (ETDEWEB)

    Batal, T., E-mail: tristan.batal@cea.fr; Richou, M.; Guilhem, D.; Firdaouss, M.; Larroque, S.; Ferlay, F.; Missirlian, M.; Bucalossi, J.

    2016-11-15

    The Tore Supra tokamak is being transformed in an x-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support to the ITER tungsten divertor strategy. The WEST project aims to test ITER-like W monoblock Plasma Facing Units (PFU). This ITER-like divertor will be tested under long plasma discharge up to 1000 s, with high heat flux density up to 20 MW/m{sup 2}. This paper presents the results of ANSYS thermal-structural simulations of the WEST upper divertor. The upper divertor is made of twelve 30° sectors, each one composed of 38 PFU. The PFUs are actively cooled CuCrZr heat sinks and the incidence surface is coated with a thin tungsten layer. The fixing system is made of pins engaged in slotted holes. Besides, the fixing system of the sector assembly is the same as WEST lower divertor, so one upper divertor sector can be used indifferently in upper or Lower position during transitional operation phases in WEST. The total surface of the upper divertor is 8 m{sup 2}, and it has to be able to extract up to 4 MW in steady-state, with peak heat flux values up to 8 MW/m{sup 2}. The fixing system was designed to handle structural loads such as forces and torques resulting from halo and eddy current, respectively, especially during disruptions and Vertical Displacement Event (VDE). The torque resulting from eddy current is first calculated thanks to an internal CEA ANSYS APDL routine. Then the ANSYS structural and thermal-structural simulations of the PFU are presented, and its design is validated thanks to A-level RCC-MRx criteria. Finally, the most conservative load case is determined in order to validate the design of the pins and the support structure.

  18. Non-ambipolar divertor flows in heliotron E

    International Nuclear Information System (INIS)

    Chechkin, V.V.; Voitsenya, V.S.; Smirnova, M.S.; Sorokovoj, E.L.; Mizuuchi, T.; Nagasaki, K.; Okada, H.; Funaba, H.; Hamada, T.; Sano, F.; Zushi, H.; Nakasuga, M.; Kondo, K.; Masuzaki, S.; Motojima, O.

    1999-01-01

    The object of the work is to find out (1) the poloidal distributions of PEC in different poloidal cross-sections of the torus within one field period; (2) the link between PEC in the divertor flows (DF) and the characteristics of the divertor field lines; (3) the effect of different methods and regimes of heating on PEC. The data having been obtained enable us to understand at least partially the nature of PEC in the diverted plasma of H-E

  19. Multi-fluid modeling of low-recycling divertor regimes

    International Nuclear Information System (INIS)

    Smirnov, R.D.; Pigarov, A.Yu.; Krasheninnikov, S.I.; Rognlien, T.D.; Soukhanovskii, V.A.; Rensink, M.E.; Maingi, R.; Skinner, C.H.; Stotler, D.P.; Bell, R.E.; Kugel, H.W.

    2010-01-01

    The low-recycling regimes of divertor operation in a single-null NSTX magnetic configuration are studied using computer simulations with the edge plasma transport code UEDGE. The edge plasma transport properties pertinent to the low-recycling regimes are demonstrated. These include the flux-limited character of the parallel heat transport and the high plasma temperatures with the flattened profiles in the scrape-off-layer. It is shown that to maintain the balance of particle fluxes at the core interface the deuterium gas puffing rate should increase as the divertor recycling coefficient decreases. The radial profiles of the heat load to the outer divertor plate, the upstream radial plasma profiles, and the effects of the cross-field plasma transport in the low-recycling regimes are discussed. It is also shown that recycling of lithium impurities evaporating from the divertor plate at high surface temperatures can reverse the low-recycling divertor operational regime to the high-recycling one and may cause thermal instability of the divertor plate (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  20. Multi-Fluid Modeling of Low-Recycling Divertor Regimes

    International Nuclear Information System (INIS)

    Smirnov, R.D.; Pigarov, A.Y.; Krasheninnikov, S.I.; Rognlien, T.D.; Soukhanovskii, V.A.; Rensink, M.E.; Maingi, R.; Skinner, C.H.; Stotler, D.P.; Bell, R.E.; Kugel, H.W.

    2010-01-01

    The low-recycling regimes of divertor operation in a single-null NSTX magnetic configuration are studied using computer simulations with the edge plasma transport code UEDGE. The edge plasma transport properties pertinent to the low-recycling regimes are demonstrated. These include the flux-limited character of the parallel heat transport and the high plasma temperatures with the flattened profiles in the scrape-off-layer. It is shown that to maintain the balance of particle fluxes at the core interface the deuterium gas puffing rate should increase as the divertor recycling coefficient decreases. The radial profiles of the heat load to the outer divertor plate, the upstream radial plasma profiles, and the effects of the cross-field plasma transport in the low-recycling regimes are discussed. It is also shown that recycling of lithium impurities evaporating from the divertor plate at high surface temperatures can reverse the low-recycling divertor operational regime to the high-recycling one and may cause thermal instability of the divertor plate.

  1. JET with a pumped divertor -- Technical issues and main results

    International Nuclear Information System (INIS)

    Bertolini, E.

    1995-01-01

    The most recent modification to JET has been the installation of a single-null pumped divertor, for active control of plasma impurities. This is to address central physics issues relevant to the design of a next step tokamak. Experiments conducted during the 1994--95 campaign, with plasma currents up to 6MA, have shown that the Mark I divertor, which makes use of strike point sweeping across the target plates, is a suitable tool to control the influx of impurities in the plasma core. The operation of a tokamak with a pumped divertor has been characterized in detail. However the divertor configuration must be optimized to better meet ITER requirements. Therefore an improved (more closed) divertor structure, which may not require sweeping, is under assembly at present (Mark II). It is designed, in addition, to allow divertor tile structures to be fully replaceable by remote handling techniques, following D-T fusion experiments. New types of events involving electromechanical interactions of plasma with the vessel and in-vessel structural components have been encountered, due to plasma vertical instabilities and disruptions (such as toroidal asymmetries of vacuum vessel forces and side-ways vessel displacements). The physics and engineering experimental work performed in JET is primarily dedicated to the finalization of the ITER design

  2. Erosion products of ITER divertor materials under plasma disruption simulation

    Energy Technology Data Exchange (ETDEWEB)

    Guseva, M.I.; Gureev, V.M.; Kolbasov, B.N.; Korshunov, S.N.; Martynenko, Yu.V. E-mail: martyn@nfi.kiae.ru; Stolyarova, V.G.; Strunnikov, V.M.; Vasiliev, V.I

    2003-09-01

    Candidate ITER divertor armor materials: carbon-fiber-composite and four tungsten grades/alloys as well as mixed re-deposited W+Be and W+C layers were exposed in electrodynamic plasma accelerator MKT which provided a pulsed deuterium plasma flux simulating plasma disruptions with maximum ion energy of 1-2 keV, an energy density of 300 kJ/m{sup 2} per shot and a pulse duration of {approx}60 {mu}s. The number of pulses was from 2 to 10. The resultant erosion products were collected on a basalt filter and Si-collectors and studied in terms of morphology and size distribution using both scanning and transmission electron microscopy. Metal erosion products usually occurred in the form of spherical droplets, sometimes flakes. Their size distribution depended on the positioning of the collector. Simultaneously irradiated W, CFC and mixed W+Be targets appeared to have undergone a greater erosion than the same targets irradiated individually. Particles sized from 0.01 to 30 {mu}m were found on collectors and on a molten W-surface. A model of droplet emission and behavior in shielding plasma is provided.

  3. R(and)D on full tungsten divertor and beryllium wall for JET ITER-like Wall Project

    International Nuclear Information System (INIS)

    Hirai, T.; Maier, H.; Rubel, M.

    2006-01-01

    The ITER-like Wall Project was initiated at JET, with the goal of testing the reference material combination chosen for ITER: beryllium (Be) in the main chamber (wall and limiters) and tungsten (W) in the divertor. The major aims are to study the tritium retention, material mixing, melt layer behavior and to optimize plasma operation scenarios with a full metal wall. The project requires major design and engineering efforts in R(and)D: (i) bulk W tile, (ii) W coatings on carbon fibre composites (CFC) (iii) Be coatings on Inconel, (iv) Be marker tiles. For the W divertor, two R(and)D tasks were initiated: (1) development of a conceptual design for a bulk W tile as the main outer divertor target plate, and (2) W coating selection from 14 different samples produced by various techniques for the other divertor plates and neutral beam shine. The bulk W tile must withstand power loads of 7 MW/m 2 for 10 s. JET divertor plates are not actively cooled, therefore, heat capacity of the tiles is an important design parameter. In addition to power handling, mechanical structural stability under electromagnetic forces and compatibility with remote handling are the key requirements in the design. The design has been completed. The test-tile survived 100 pulses at 7 MW/m 2 for 10 s in the electron beam facility, JUDITH. The W coatings with different thickness, thin ( 2 and 200 pulses at 10 MW/m 2 for 5 s. In all tested samples cracks developed perpendicularly to the fiber bundles in CFC because of contraction of the coating in the cooling phase. Coatings were also exposed to 1000 ELM-like loading pulses. The thin coatings showed fatigue leading to delamination, whereas for thick coatings better resistance in ELM-like loading. As a result of R(and)D a full W divertor was decided: bulk metal at the outer divertor and W coating at other areas. Be-related R(and)D activities are in two areas. Production of 8-9 μm layers on inner wall cladding Inconel tiles ensures the full coating of

  4. Numerical study of the ITER divertor plasma with the B2-EIRENE code package

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, V.; Reiter, D. [Forschungszentrum Juelich (DE). Inst. fuer Energieforschung (IEF), Plasmaphysik (IEF-4); Kukushkin, A.S. [ITER International Team, Cadarache (France)

    2007-11-15

    The problem of plasma-wall interaction and impurity control is one of the remaining critical issues for development of an industrial energy source based on nuclear fusion of light isotopes. In this field sophisticated integrated numerical tools are widely used both for the analysis of current experiments and for predictions guiding future device design. The present work is dedicated to the numerical modelling of the edge plasma region in divertor configurations of large-scale tokamak fusion devices. A well established software tool for this kind of modelling is the B2-EIRENE code. It was originally developed for a relatively hot (>> 10 eV) ''high recycling divertor''. It did not take into account a number of physical effects which can be potentially important for ''detached conditions'' (cold, - several eV, - high density, - {approx} 10{sup 21} m{sup -3}, - plasma) typical for large tokamak devices. This is especially critical for the modelling of the divertor plasma of ITER: an international project of an experimental tokamak fusion reactor to be built in Cadarache, France by 2016. This present work is devoted to a major upgrade of the B2-EIRENE package, which is routinely used for ITER modelling, essentially with a significantly revised version of EIRENE: the Monte-Carlo neutral transport code. The main part of the thesis address three major groups of the new physical effects which have been added to the model in frame of this work: the neutral-neutral collisions, the up-to date hydrogen molecular reaction kinetics and the line radiation transport. The impact of the each stage of the upgrade on the self-consistent (between plasma, the neutral gas and the radiation field) solution for the reference ITER case is analysed. The strongest effect is found to be due to the revised molecular collision kinetics, in particular due to hitherto neglected elastic collisions of hydrogen molecules with ions. The newly added non

  5. Numerical study of the ITER divertor plasma with the B2-EIRENE code package

    International Nuclear Information System (INIS)

    Kotov, V.; Reiter, D.; Kukushkin, A.S.

    2007-11-01

    The problem of plasma-wall interaction and impurity control is one of the remaining critical issues for development of an industrial energy source based on nuclear fusion of light isotopes. In this field sophisticated integrated numerical tools are widely used both for the analysis of current experiments and for predictions guiding future device design. The present work is dedicated to the numerical modelling of the edge plasma region in divertor configurations of large-scale tokamak fusion devices. A well established software tool for this kind of modelling is the B2-EIRENE code. It was originally developed for a relatively hot (>> 10 eV) ''high recycling divertor''. It did not take into account a number of physical effects which can be potentially important for ''detached conditions'' (cold, - several eV, - high density, - ∼ 10 21 m -3 , - plasma) typical for large tokamak devices. This is especially critical for the modelling of the divertor plasma of ITER: an international project of an experimental tokamak fusion reactor to be built in Cadarache, France by 2016. This present work is devoted to a major upgrade of the B2-EIRENE package, which is routinely used for ITER modelling, essentially with a significantly revised version of EIRENE: the Monte-Carlo neutral transport code. The main part of the thesis address three major groups of the new physical effects which have been added to the model in frame of this work: the neutral-neutral collisions, the up-to date hydrogen molecular reaction kinetics and the line radiation transport. The impact of the each stage of the upgrade on the self-consistent (between plasma, the neutral gas and the radiation field) solution for the reference ITER case is analysed. The strongest effect is found to be due to the revised molecular collision kinetics, in particular due to hitherto neglected elastic collisions of hydrogen molecules with ions. The newly added non-linear effects (neutral-neutral collisions, radiation opacity

  6. Coupled behavior of shape memory alloy-based morphing spacecraft radiators: experimental assessment and analysis

    Science.gov (United States)

    Bertagne, C.; Walgren, P.; Erickson, L.; Sheth, R.; Whitcomb, J.; Hartl, D.

    2018-06-01

    Thermal control is an important aspect of spacecraft design, particularly in the case of crewed vehicles, which must maintain a precise internal temperature at all times in spite of significant variations in the external thermal environment and internal heat loads. Future missions beyond low Earth orbit will require radiator systems with high turndown ratios, defined as the ratio between the maximum and minimum heat rejection rates achievable by the radiator system. Current radiators are only able to achieve turndown ratios of 3:1, far less than the 12:1 turndown ratio requirement expected for future missions. An innovative morphing radiator concept uses the temperature-induced phase transformation of shape memory alloy (SMA) materials to achieve turndown ratios that are predicted to exceed 12:1 via substantial geometric reconfiguration. Developing mathematical and computational models of these morphing radiators is challenging due to the strong two-way thermomechanical coupling not present in traditional fixed-geometry radiators and not widely considered in the literature. Although existing simulation tools are capable of analyzing the behavior of some thermomechanically coupled structures, general problems involving radiation and deformation cannot be modeled using publicly available codes due to the complexity of modeling spatially evolving boundary fields. This paper provides important insight into the operational response of SMA-based morphing radiators by employing computational tools developed to overcome previous shortcomings. Several example problems are used to demonstrate the novel radiator concept. Additionally, a prototype morphing radiator was designed, fabricated, and tested in a thermal environment compatible with mission operations. An associated finite element model of the prototype was developed and executed. Model predictions of radiator performance generally agree with the experimental data, giving confidence that the tools developed are able

  7. Comment on “Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake” [Phys. Plasmas 20, 102507 (2013)

    International Nuclear Information System (INIS)

    Ryutov, D. D.; Cohen, R. H.; Rognlien, T. D.; Soukhanovskii, V. A.; Umansky, M. V.

    2014-01-01

    In the recently published paper “Magnetic geometry and physics of advanced divertors: The X-divertor and the snowflake” [Phys. Plasmas 20, 102507 (2013)], the authors raise interesting and important issues concerning divertor physics and design. However, the paper contains significant errors: (a) The conceptual framework used in it for the evaluation of divertor “quality” is reduced to the assessment of the magnetic field structure in the outer Scrape-Off Layer. This framework is incorrect because processes affecting the pedestal, the private flux region and all of the divertor legs (four, in the case of a snowflake) are an inseparable part of divertor operation. (b) The concept of the divertor index focuses on only one feature of the magnetic field structure and can be quite misleading when applied to divertor design. (c) The suggestion to rename the divertor configurations experimentally realized on NSTX (National Spherical Torus Experiment) and DIII-D (Doublet III-D) from snowflakes to X-divertors is not justified: it is not based on comparison of these configurations with the prototypical X-divertor, and it ignores the fact that the NSTX and DIII-D poloidal magnetic field geometries fit very well into the snowflake “two-null” prescription

  8. Power balance for impurity seeded ergodic divertor discharges in Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Reichle, R.; Vallet, J.C.; Basiuk, V.; Chantant, M.; Giannella, R.; Guirlet, R.; Mitteau, R

    1999-10-15

    The main emphasis of the present contribution is the search for independent indications concerning local radiation enhancement in the vicinity of target plates by the application of the power-balance analysis to impurity seeded discharges and the use of spatially resolved calorimetry. All methods confirm the existence of an important local radiation enhancement in front of target objects. Their torlly localised nature and the lack of short scale toroidal resolution of the bolometers cause an underestimate of the radiation. Observed corrective factors for radiative divertor discharges range between 1.1 and 1.6 depending on the density. the impurity seeded discharges show during the impurity injection a reduction of this factor which can be explained by the radiation distribution becoming toroidally more symmetric due to larger ionisation lengths. The consistency of the results seems to validate the assumption of a fall off length of the radiation of 40 cm as used for the radiation extrapolation from the outboard calorimetry. The localised extra radiation falling onto one individual neutralizer is about 1 kW. This should be compared with spectroscopic radiation measurements and modelling to see whether there is room for charge exchange neutrals to be important. (authors)

  9. Power balance for impurity seeded ergodic divertor discharges in Tore Supra

    International Nuclear Information System (INIS)

    Reichle, R.; Vallet, J.C.; Basiuk, V.; Chantant, M.; Giannella, R.; Guirlet, R.; Mitteau, R.

    1999-01-01

    The main emphasis of the present contribution is the search for independent indications concerning local radiation enhancement in the vicinity of target plates by the application of the power-balance analysis to impurity seeded discharges and the use of spatially resolved calorimetry. All methods confirm the existence of an important local radiation enhancement in front of target objects. Their toroidally localised nature and the lack of short scale toroidal resolution of the bolometers cause an underestimate of the radiation. Observed corrective factors for radiative divertor discharges range between 1.1 and 1.6 depending on the density. the impurity seeded discharges show during the impurity injection a reduction of this factor which can be explained by the radiation distribution becoming toroidally more symmetric due to larger ionisation lengths. The consistency of the results seems to validate the assumption of a fall off length of the radiation of 40 cm as used for the radiation extrapolation from the outboard calorimetry. The localised extra radiation falling onto one individual neutralizer is about 1 kW. This should be compared with spectroscopic radiation measurements and modelling to see whether there is room for charge exchange neutrals to be important. (authors)

  10. Safety practices, perceptions, and behaviors in radiation oncology: A national survey of radiation therapists.

    Science.gov (United States)

    Woodhouse, Kristina Demas; Hashemi, David; Betcher, Kathryn; Doucette, Abigail; Weaver, Allison; Monzon, Brian; Rosenthal, Seth A; Vapiwala, Neha

    Radiation therapy is complex and demands high vigilance and precise coordination. Radiation therapists (RTTs) directly deliver radiation and are often the first to discover an error. Yet, few studies have examined the practices of RTTs regarding patient safety. We conducted a national survey to explore the perspectives of RTTs related to quality and safety. In 2016, an electronic survey was sent to a random sample of 1500 RTTs in the United States. The survey assessed department safety, error reporting, safety knowledge, and culture. Questions were multiple choice or recorded on a Likert scale. Results were summarized using descriptive statistics and analyzed using multivariate logistic regression. A total of 702 RTTs from 49 states (47% response rate) completed the survey. Respondents represented a broad distribution across practice settings. Most RTTs rated department patient safety as excellent (61%) or very good (32%), especially if they had an incident learning system (ILS) (odds ratio, 2.0). Only 21% reported using an ILS despite 58% reporting an accessible ILS in their department. RTTs felt errors were most likely to occur with longer shifts and poor multidisciplinary communication; 40% reported that burnout and anxiety negatively affected their ability to deliver care. Workplace bullying was also reported among 17%. Overall, there was interest (62%) in improving knowledge in patient safety. Although most RTTs reported excellent safety cultures within their facilities, overall, there was limited access to and utilization of ILSs by RTTs. Workplace issues identified may also represent barriers to delivering quality care. RTTs were also interested in additional resources regarding quality and safety. These results will further enhance safety initiatives and inform future innovative educational efforts in radiation oncology. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  11. Divertor characteristics and control on the W-shaped divertor with pump of JT-60U

    International Nuclear Information System (INIS)

    Hosogane, N.; Kubo, H.; Higashijima, S.

    1999-01-01

    Roles of the inner leg pumping and the private dome, which are special features of the W-shaped divertor of JT-60U, have been investigated. The following observations were made: The inner leg pumping functions well in attached states or partially detached states with weak X-point MARFE where the inner particle recycling is enhanced. A combination of main gas puff and inner leg pump is effective in reduction of intrinsic carbon impurity. Geometrical effects of the private dome on transport of hydrocarbons in the private flux region was confirmed by spectroscopic measurements of CD-band intensity profile and impurity transport simulation code using experimental data. (author)

  12. Design of the advanced divertor pump cryogenic system for DIII-D

    International Nuclear Information System (INIS)

    Schaubel, K.M.; Baxi, C.B.; Campbell, G.L.; Gootgeld, A.M.; Langhorn, A.R.; Laughon, G.J.; Smith, J.P.; Anderson, P.M.; Menon, M.M.

    1991-11-01

    The design of the cryogenic system for the D3-D advanced divertor cryocondensation pump is presented. The advanced divertor incorporates a baffle chamber and bias ring located near the bottom of the D3-D vacuum vessel. A 50,000 l/s cryocondensation pump will be installed underneath the baffle for plasma particle exhaust. The pump consists of a liquid helium cooled tube operating at 4.3 degrees K and a liquid nitrogen cooled radiation shield. Liquid helium is fed by forced flow through the cryopump. Compressed helium gas flowing through the high pressure side of a heat exchanger is regeneratively cooled by the two-phase helium leaving the pump. The cooled high pressure gaseous helium is than liquefied by a Joule-Thomson expansion valve. The liquid is returned to a storage dewar. The liquid nitrogen for the radiation shield is supplied by forced flow from a bulk storage system. Control of the cryogenic system is accomplished by a programmable logic controller

  13. Variation of Particle Control with Changes in Divertor Geometry

    International Nuclear Information System (INIS)

    Petrie, T W; Allen, S L; Brooks, N H; Fenstermacher, M E; Ferron, J R; Greenfield, C M; Groth, M; Hyatt, A W; Leonard, A W; Luce, T C; Mahdavi, M A; Murakami, M; Porter, G D; Rensink, M E; Schaffer, M J; Wade, M R; Watkins, J G; West, W P; Wolf, N S

    2004-01-01

    Recent experiments on DIII-D point to the importance of two factors in determining how effectively the deuterium particle inventory in a tokamak plasma can be controlled through pumping at the divertor target(s): (1) the divertor magnetic balance, i.e., the degree to which the divertor topology is single-null (SN) or double-null (DN), and (2) the direction of the of Bx(divergent)B ion drift with respect to the X-point(s). Changes in divertor magnetic balance near the DN shape have a much stronger effect on the particle exhaust rate at the inner divertor target(s) than on the particle exhaust rate at the outer divertor target(s). The particle exhaust rate for the DN shape is strongest at the outer strike point opposite the Bx(divergent)B ion particle drift direction. Our data suggests that the presence of Bx(divergent)B and ExB ion particle drifts in the scrapeoff layer (SOL) and divertors play an important role in the particle exhaust rates of DN and near-DN plasmas. Particle exhaust rates are shown to depend strongly on the edge (pedestal) density n e,PED . In the lower range of densities considered in this study, i.e., n e,PED / n GREENWALD <0.4, particle exhaust rates are also found to be approximately proportional to the deuterium recycling intensity in front of the respective plenum entrance. Our results are shown to have implications for particle control in ITER and other future tokamaks

  14. Variation of particle control with changes in divertor geometry

    International Nuclear Information System (INIS)

    Petrie, T.W.; Allen, S.L.; Brooks, N.H.; Fenstermacher, M.E.; Groth, M.; Porter, G.D.; Rensink, M.E.; Wolf, N.S.; Ferron, J.R.; Greenfield, C.M.; Hyatt, A.W.; Leonard, A.W.; Luce, T.C.; Mahdavi, M.A.; Schaffer, M.J.; West, W.P.; Murakami, M.; Wade, M.R.; Watkins, J.G.

    2005-01-01

    Recent experiments on DIII-D point to the importance of two factors in determining how effectively the deuterium particle inventory in a tokamak plasma can be controlled through pumping at the divertor target(s): (1) the divertor magnetic balance, i.e., the degree to which the divertor topology is single-null (SN) or double-null (DN), and (2) the direction of the of Bx∇B ion drift with respect to the X-point(s). Changes in divertor magnetic balance near the DN shape have a much stronger effect on the particle exhaust rate at the inner divertor target(s) than on the particle exhaust rate at the outer divertor target(s). The particle exhaust rate for the DN shape is strongest at the outer strike point opposite the Bx∇B ion particle drift direction. Our data suggests that the presence of Bx∇B and ExB ion particle drifts in the scrapeoff layer (SOL) and divertors play an important role in the particle exhaust rates of DN and near-DN plasmas. Particle exhaust rates are shown to depend strongly on the edge (pedestal) density n e,PED . In the lower range of densities considered in this study, i.e., n e,PED /n GREENWALD <0.4, particle exhaust rates are also found to be approximately proportional to the deuterium recycling intensity in front of the respective plenum entrance. Our results are shown to have implications for particle control in ITER and other future tokamaks. (author)

  15. Design, R&D and commissioning of EAST tungsten divertor

    Science.gov (United States)

    Yao, D. M.; Luo, G. N.; Zhou, Z. B.; Cao, L.; Li, Q.; Wang, W. J.; Li, L.; Qin, S. G.; Shi, Y. L.; Liu, G. H.; Li, J. G.

    2016-02-01

    After commissioning in 2005, the EAST superconducting tokamak had been operated with its water cooled divertors for eight campaigns up to 2012, employing graphite as plasma facing material. With increase in heating power over 20 MW in recent years, the heat flux going to the divertors rises rapidly over 10 MW m-2 for steady state operation. To accommodate the rapid increasing heat load in EAST, the bolting graphite tile divertor must be upgraded. An ITER-like tungsten (W) divertor has been designed and developed; and firstly used for the upper divertor of EAST. The EAST upper W divertor is modular structure with 80 modules in total. Eighty sets of W/Cu plasma-facing components (PFC) with each set consisting of an outer vertical target (OVT), an inner vertical target (IVT) and a DOME, are attached to 80 stainless steel cassette bodies (CB) by pins. The monoblock W/Cu-PFCs have been developed for the strike points of both OVT and IVT, and the flat type W/Cu-PFCs for the DOME and the baffle parts of both OVT and IVT, employing so-called hot isostatic pressing (HIP) technology for tungsten to CuCrZr heat sink bonding, and electron beam welding for CuCrZr to CuCrZr and CuCrZr to other material bonding. Both monoblock and flat type PFC mockups passed high heat flux (HHF) testing by means of electron beam facilities. The 80 divertor modules were installed in EAST in 2014 and results of the first commissioning are presented in this paper.

  16. A computational study of operating regimes for poloidal divertors

    International Nuclear Information System (INIS)

    Petravic, M.; Heifetz, D.; Post, D.

    1982-01-01

    We have identified three theoretical operating regimes for poloidal divertors. These regimes are determined by the geometry of the divertor and the input energy and particle fluxes, and are characterized by the divertor plasma density and temperature. A fully self-consistent two-dimensional model for the plasma and neutral atom and molecule transport was used to study poloidal divertor operation. Extensions of our previous calculations important to this study were the inclusion of parallel electron and ion thermal conduction. We find that the key physics in divertor operation is the neutral recycling near the neutralizer plate. This can be parametrized by R = GAMMAsub(P)/GAMMAsub(O), the ratio of particle flux striking the neutralizer plate to the particle flux entering the divertor. Values of R approx. equal to 1 can be produced by large pumping rates near the neutralizer plates resulting in low neutral recycling and a high temperature, low density divertor plasma. By decreasing the pumping near the neutralizer plate, R can be raised to an intermediate value of 5-10, the plasma temperature lowered by the same factor, and the density raised by a factor of 10-30. In this regime, escape of the neutrals back to the main plasma is virtually blocked. By further restricting the pumping, R can be raised to twenty or more, thereby lowering the temperature by a factor of twenty or more and raising the density by a factor of ninety or more. Such high density regimes have been observed on D-III and appear to offer the most promise for impurity control and particle control on large reactor experiments such as INTOR or FED. In this paper, we explore the range 3 < R < 16. (orig.)

  17. Thermographic observation of the divertor target plates in the stellarators W7-AS and W7-X

    International Nuclear Information System (INIS)

    Hildebrandt, D.; Gadelmeier, F.; Grigull, P.; McCormick, K.; Naujoks, D.; Suender, D.

    2003-01-01

    Thermography is applied on the stellarator W7-AS to monitor the thermal load of the recently installed divertor targets. A three dimensional numerical code was developed to evaluate power fluxes arriving at the targets from the measured temporal evolution of the surface temperature distribution. Values of the thermal conductivity of the used CFC-target material for all three directions are required for this evaluation and determined by observing the propagation of controlled heat pulses applied by an infrared laser. The evaluation of the thermographic measurements during plasma operation shows characteristic spatial and temporal features of the arrived heat fluxes. Significant features in high density regimes like plasma detachment from the divertor target plates or strongly enhanced localised plasma radiation (MARFE) has been observed by the installed infrared cameras. The implications of these observations for the thermographic system for W7-X are shortly addressed

  18. First measurements of the ion energy distribution at the divertor strike point during DIII-D disruptions

    International Nuclear Information System (INIS)

    Parks, P.B.; Brooks, N.H.; West, W.P.; Wong, C.P.C.; Bastasz, R.; Wampler, W.R.; Whyte, D.

    1995-12-01

    Plasma/wall interaction studies are being carried out using the Divertor Materials Exposure System (DiMES) on DIII-D. The objective of the experiment is to determine the kinetic energy and flux of deuterium ions reaching the divertor target during argon-induced radiative disruptions. The experiment utilizes a special slotted ion analyzer mounted over a Si sample to collect the fast charge-exchange (CX) deuterium neutrals emitted within the recycled cold neutral layer (CNL) which serves as a CX target for the incident ions. A theoretical interpretation of the experiment reveals a strong forward pitch-angle dependence in the approaching ion distribution function. The depth distribution of the trapped D in the Si sample was measured using low-energy direct recoil spectroscopy. Comparison with the TRIM code using monoenergetic ions indicated that the best fit to the data was obtained for an ion energy of 100 eV

  19. LONG-TERM RADIATIVE BEHAVIOR OF SGR 1900+14

    International Nuclear Information System (INIS)

    Goegues, Ersin; Guever, Tolga; Oezel, Feryal; Eichler, David; Kouveliotou, Chryssa

    2011-01-01

    The prolific magnetar SGR 1900+14 showed two outbursts in the last decade and has been closely monitored in the X-rays to track the changes in its radiative properties. We use archival Chandra and XMM-Newton observations of SGR 1900+14 to construct a history of its spectrum and persistent X-ray flux spanning a period of about seven years. We show that the decline of its X-ray flux in these two outburst episodes follows the same trend. The flux begins to decline promptly and rapidly subsequent to the flares, then decreases gradually for about 600 days, at which point it resumes a more rapid decline. Utilizing the high-quality spectral data in each epoch, we also study the spectral coevolution of the source with its flux. We find that neither the magnetic field strength nor the magnetospheric properties change over the period spanned by the observations, while the surface temperature as well as the inferred emitting area both decline with time following both outbursts. We also show that the source reached the same minimum flux level in its decline from these two subsequent outbursts, suggesting that this flux level may be its steady quiescent flux.

  20. Radiation chemical behavior of Rh(III) in HClO4 and HNO3

    International Nuclear Information System (INIS)

    Vladimirova, M.V.; Khalkina, E.V.

    1995-01-01

    The radiation chemical behavior of Rh is very interesting since Rh accumulates in irradiated U but has not been reported in the literature. Scattered data do exist for the radiation chemical behavior of Rh(III) in weakly acidic and alkaline solutions. Pulsed radiolysis was used to investigate the formation of unstable oxidation states of Rh during reduction and oxidation of Rh(III) in neutral solutions. The rate constant of the reaction Rh(III) + e aq - was found to be 6·10 10 liter/mole·sec. The radiation chemical behavior of Rh(III) toward γ-radiolysis in neutral, weakly acidic (up to 0.1 N), and alkaline solutions was examined. In neutral solutions of [Rh(NH 3 ) 5 Cl]Cl 2 and RhCl 3 , metallic Rh is formed. The degree of reduction is ∼ 1%. In neutral and weakly acidic solutions of Rh(NO 3 ) 3 , Rh 2 O 3 ·xH 2 O is formed. Irradiation of Rh(ClO 4 ) 3 solutions produces no reduction. The radiation chemical behavior of Rh(III) in HClO 4 and HNO 3 solutions at concentrations > 1 M is studied in the present work

  1. Radiation damage and defect behavior in ion-implanted, lithium counterdoped silicon solar cells

    Science.gov (United States)

    Weinberg, I.; Mehta, S.; Swartz, C. K.

    1984-01-01

    Boron doped silicon n+p solar cells were counterdoped with lithium by ion implantation and the resuitant n+p cells irradiated by 1 MeV electrons. The function of fluence and a Deep Level Transient Spectroscopy (DLTS) was studied to correlate defect behavior with cell performance. It was found that the lithium counterdoped cells exhibited significantly increased radiation resistance when compared to boron doped control cells. It is concluded that the annealing behavior is controlled by dissociation and recombination of defects. The DLTS studies show that counterdoping with lithium eliminates at least three deep level defects and results in three new defects. It is speculated that the increased radiation resistance of the counterdoped cells is due primarily to the interaction of lithium with oxygen, single vacanies and divacancies and that the lithium-oxygen interaction is the most effective in contributing to the increased radiation resistance.

  2. Comparison study of toroidal-field divertors for a compact reversed-field pinch reactor

    International Nuclear Information System (INIS)

    Bathke, C.G.; Krakowski, R.A.; Miller, R.L.

    1985-01-01

    Two divertor configurations for the Compact Reversed-Field Pinch Reactor (CRFPR) based on diverting the minority (toroidal) field have been reported. A critical factor in evaluating the performance of both poloidally symmetric and bundle divertor configurations is the accurate determination of the divertor connection length and the monitoring of magnetic islands introduced by the divertors, the latter being a three-dimensional effect. To this end the poloidal-field, toroidal-field, and divertor coils and the plasma currents are simulated in three dimensions for field-line tracings in both the divertor channel and the plasma-edge regions. The results of this analysis indicate a clear preference for the poloidally symmetric toroidal-field divertor. Design modifications to the limiter-based CRFPR design that accommodate this divertor are presented

  3. Two-dimensional impurity transport calculations for a high recycling divertor

    International Nuclear Information System (INIS)

    Brooks, J.N.

    1986-04-01

    Two dimensional analysis of impurity transport in a high recycling divertor shows asymmetric particle fluxes to the divertor plate, low helium pumping efficiency, and high scrapeoff zone shielding for sputtered impurities

  4. Efficiency of water coolant for DEMO divertor

    International Nuclear Information System (INIS)

    Fetzer, Renate; Igitkhanov, Yuri; Bazylev, Boris

    2015-01-01

    Up to now, water-cooled divertor concepts have been developed for limited incident fluxes without taking into account transient power loadings. In this paper we analyzed the efficiency of water as a coolant for the particular PFC tungsten monoblock shield with a cooling tube made from Cu alloy (Cu OFHC) as a laminate adjacent to W and a low activation martensitic steel (Eurofer) as inner tube contacting the coolant. Thermal analysis is carried out by using the code MEMOS, which simulates W armour damage under the repetitive ELM heat loads. We consider cooling conditions which allow one to keep relatively high material temperatures (in the range 300–600 °C) thus minimizing Eurofer embrittlement under neutron irradiation. Expected DEMO I and DEMO II heat loads including type I ELMs are found to cause melting of the W surface during unmitigated ELMs. By mitigation of the ELMs melting of W is avoided. DEMO I operation under these conditions is save for cooling at water pressure 15.5 MPa and temperature 325 °C, while for DEMO II with mitigated ELMs the critical heat flux is exceeded and safe operation is not provided.

  5. The edge plasma and divertor in TIBER

    Energy Technology Data Exchange (ETDEWEB)

    Barr, W.L.

    1987-10-16

    An open divertor configuration has been adopted for TIBER. Most recent designs, including DIII-D, NET and CIT use open configurations and rely on a dense edge plasma to shield the plasma from the gas produced at the neutralizer plate. Experiments on ASDEX, PDX, D-III, and recently on DIII-D have shown that a dense edge plasma can be produced by re-ionizing most of the gas produced at the plate. This high recycling mode allows a large flux of particles to carry the heat to the plate, so that the mean energy per particle can be low. Erosion of the plate can be greatly reduced if the average impact energy of the ions at the plate can be reduced to near or below the threshold for sputtering of the plate material. The present configuration allows part of the flux of edge plasma ions to be neutralized at the entrance to the pumping duct so that helium is pumped as well as hydrogen. 7 refs., 3 figs.

  6. Efficiency of water coolant for DEMO divertor

    Energy Technology Data Exchange (ETDEWEB)

    Fetzer, Renate, E-mail: renate.fetzer@kit.edu; Igitkhanov, Yuri; Bazylev, Boris

    2015-10-15

    Up to now, water-cooled divertor concepts have been developed for limited incident fluxes without taking into account transient power loadings. In this paper we analyzed the efficiency of water as a coolant for the particular PFC tungsten monoblock shield with a cooling tube made from Cu alloy (Cu OFHC) as a laminate adjacent to W and a low activation martensitic steel (Eurofer) as inner tube contacting the coolant. Thermal analysis is carried out by using the code MEMOS, which simulates W armour damage under the repetitive ELM heat loads. We consider cooling conditions which allow one to keep relatively high material temperatures (in the range 300–600 °C) thus minimizing Eurofer embrittlement under neutron irradiation. Expected DEMO I and DEMO II heat loads including type I ELMs are found to cause melting of the W surface during unmitigated ELMs. By mitigation of the ELMs melting of W is avoided. DEMO I operation under these conditions is save for cooling at water pressure 15.5 MPa and temperature 325 °C, while for DEMO II with mitigated ELMs the critical heat flux is exceeded and safe operation is not provided.

  7. The edge plasma and divertor in TIBER

    International Nuclear Information System (INIS)

    Barr, W.L.

    1987-01-01

    An open divertor configuration has been adopted for TIBER. Most recent designs, including DIII-D, NET and CIT use open configurations and rely on a dense edge plasma to shield the plasma from the gas produced at the neutralizer plate. Experiments on ASDEX, PDX, D-III, and recently on DIII-D have shown that a dense edge plasma can be produced by re-ionizing most of the gas produced at the plate. This high recycling mode allows a large flux of particles to carry the heat to the plate, so that the mean energy per particle can be low. Erosion of the plate can be greatly reduced if the average impact energy of the ions at the plate can be reduced to near or below the threshold for sputtering of the plate material. The present configuration allows part of the flux of edge plasma ions to be neutralized at the entrance to the pumping duct so that helium is pumped as well as hydrogen. 7 refs., 3 figs

  8. Progressive behavioral changes in rats after exposure to low levels of ionizing radiation in utero

    International Nuclear Information System (INIS)

    Norton, S.; Kimler, B.F.; Mullenix, P.J.

    1991-01-01

    The deleterious effects of ionizing radiation on the developing brain may be not only prolonged but progressive. Fetuses were exposed to 0.75 Gy of ionizing radiation on gestational day 15 through whole body exposure of the pregnant rat. Three behavioral tests (gait analysis, continuous corridor activity and photographic analysis of sequences of behavioral acts) were performed at 1 and 3 months, postnatally. Body weight and thickness of the cerebral cortex of irradiated rats were 10-15 percent below controls throughout the period of study. Behavior in all tests was more affected at 3 months than at 1 month of age. Gait of control rats, as measured by the angle of advanced of hind feet, widened about 20 percent for males and 40 percent for females from 1 to 3 months, as expected, while, in irradiated rats, the angle widened only about 10 percent. Continuous corridor activity increased less than 10 percent in controls and about 35 percent in irradiated rats over the same period. In photographic analysis of behavior, controls increased their time spent standing by about 50 percent in males and 20 percent in females from 1 to 3 months of age. Irradiated males increased time standing only about 10 percent and irradiated females decreased about 30 percent over the same period. The data obtained in these experiments support other evidence that some behavioral alterations from perinatal exposure to radiation become more marked with maturation

  9. Impulsive behavior in solar soft X-radiation

    Science.gov (United States)

    Hudson, H. S.; Strong, K. T.; Dennis, B. R.; Zarro, D.; Inda, M.; Kosugi, T.; Sakao, T.

    1994-01-01

    The Yohkoh soft X-ray telescope has observed impulsive, thermal, soft X-ray emission at the footpoints of magnetic loops during solar flares. The soft X-ray (thermal) time profiles at the footpoints closely match the hard X-ray (nonthermal) time profiles, directly demonstrating the heating of the lower solar atmosphere on short timescales during the interval of nonthermal energy release. This phenomenon is the rule, rather than the exception, occurring in the majority of flares that we have examined with the Yohkoh data. We illustrate the impulsive behavior with data from the major flare of 1992 January 26. For this flare, the soft X-ray peak times matched the hard X-ray peak times within the time resolution of the soft X-ray measurements (about 10 s), and the soft and hard X-ray locations match within the resolution of the hard X-ray imager. The impulsive soft X-ray emission clearly has a thermal spectral signature, but not at the high temperature of a 'superhot' source. We conclude that the impulsive soft X-ray emission comes from material heated by precipitating electrons at loop footpoints and evaporating from the deeper atmosphere into the flaring flux tube.

  10. Theory and Simulations of ELM Control with a Snowflake Divertor

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Cohen, B.; Cohen, R.; Makowski, M. A.; Menard, J.; Rognlien, T.; Soukhanovskii, V.; Umansky, M.; Xu, X., E-mail: ryutov1@llnl.gov [Lawrence Livermore National Laboratory, Livermore (United States); Kolemen, E. [Princeton Plasma Physics Laboratory, Princeton (United States)

    2012-09-15

    Full text: This paper is concerned with the use of a snowflake (SF) divertor for the control and mitigation of edge localized modes (ELMs). Our research is focused on the following three issues: 1. Effect of the SF geometry on neoclassical ion orbits near the separatrix, including prompt ion losses and the related control mechanism for the electric field and plasma flow in the pedestal; 2. Influence of the thereby modified flow and of high poloidal plasma beta in the divertor region on plasma turbulence and transport in the snowflake-plus geometry; 3. Reaction of the SF divertor to type-1 ELM events. Neoclassical ion orbits in the vicinity of the SF separatrix are changed due to a much weaker poloidal field near the null and much longer particle dwell-time in this area. This leads to an increase of the prompt ion loss, which then affects the radial electric field profile near the separatrix. The resulting E x B flow shear in the pedestal region affects the onset of ELMs. The electric field and velocity shear are then used as a background for two-fluid simulations of the edge plasma turbulence in a realistic geometry with the 3D BOUT code. A SF-plus geometry is chosen, so that the separatrix topology remains the same as for the standard X-point divertor, whereas the magnetic shear both inside and outside the separatrix increases dramatically. It is found that mesoscale instabilities are suppressed when the geometry is close to a perfect SF. In situations where complete suppression of ELMs is impossible, the SF divertor offers a path to reducing heat loads during ELM events to an acceptable level. Two effects, both related to the weakness of the poloidal field near the SF null, act synergistically in the same favorable direction. The first is the onset of strong, curvature-driven convection in the divertor, triggered by the increase of the poloidal pressure during the ELM and leading to the splitting of the heat flux between all four (as is the case in a SF geometry

  11. Behavior and memory evaluation of Wistar rats exposed to 1·8 GHz radiofrequency electromagnetic radiation.

    Science.gov (United States)

    Júnior, Luiz Carlos de Caires; Guimarães, Ernesto da Silveira Goulart; Musso, Camila Manso; Stabler, Collin Turner; Garcia, Raúl Marcel González; Mourão-Júnior, Carlos Alberto; Andreazzi, Ana Eliza

    2014-09-01

    The development of communication systems has brought great social and economic benefits to society. As mobile phone use has become widespread, concerns have emerged regarding the potential adverse effects of radiofrequency electromagnetic radiation (RF-EMR) used by these devices. To verify potential effects of mobile phone radiation on the central nervous system (CNS) in an animal model. Male Wistar rats (60 days old) were exposed to RF-EMR from a Global System for Mobile (GSM) cell phone (1·8 GHz) for 3 days. At the end of the exposure, the following behavioral tests were performed: open field and object recognition. Our results showed that exposed animals did not present anxiety patterns or working memory impairment, but stress behavior actions were observed. Given the results of the present study, we speculate that RF-EMR does not promote CNS impairment, but suggest that it may lead to stressful behavioral patterns.

  12. Probabilistic analysis of divertor plate lifetime in tokamak reactors

    International Nuclear Information System (INIS)

    Golinescu, R.P.; Kazimi, M.S.

    1994-01-01

    Defining a methodology for a reliability estimate of the International Tokamak Experimental Reactor (ITER) divertor is the objective of the study summarized in this paper. If ITER could be designed such that no transients of any type occurred, the divertor reliability would be controlled by erosion of material during normal operation. The occurrence of several transient events results in important contribution to the expected divertor failure rate. Some transients cause the temperature in the divertor plate (DP) to rise; if these temperatures get too high, the structural elements in the DP will weaken and subsequently suffer structural failure and possibly reach the melting temperature. Using the limited data available leads to the result that there is a high probability that the DP will reliably withstand a peak heat flux of 11 MW/m 2 . However, transient events will lead to a much shorter lifetime than desirable for DP's, mainly due to the expected severe effects of plasma disruptions. If transients occurred, but the shutdown mechanism succeeded to perform without inducing a disruption, divertor reliability could be significantly improved. Improved characterization of the disruption conditions, and enlarged scope of failure modes should be pursued to gain confidence in the present conclusions

  13. Optimal thermal-hydraulic performance for helium-cooled divertors

    International Nuclear Information System (INIS)

    Izenson, M.G.; Martin, J.L.

    1996-01-01

    Normal flow heat exchanger (NFHX) technology offers the potential for cooling divertor panels with reduced pressure drops (<0.5% Δp/p), reduced pumping power (<0.75% pumping/thermal power), and smaller duct sizes than conventional helium heat exchangers. Furthermore, the NFHX can easily be fabricated in the large sizes required for divertors in large tokamaks. Recent experimental and computational results from a program to develop NFHX technology for divertor coolings using porous metal heat transfer media are described. We have tested the thermal and flow characteristics of porous metals and identified the optimal heat transfer material for the divertor heat exchanger. Methods have been developed to create highly conductive thermal bonds between the porous material and a solid substrate. Computational fluid dynamics calculations of flow and heat transfer in the porous metal layer have shown the capability of high thermal effectiveness. An 18-kW NFHX, designed to meet specifications for the international Thermonuclear Experimental Reactor divertor, has been fabricated and tested for thermal and flow performance. Preliminary results confirm design and fabrication methods. 11 refs., 12 figs., 1 tab

  14. Analysis of sweeping heat loads on divertor plate materials

    International Nuclear Information System (INIS)

    Hassanein, A.

    1991-01-01

    The heat flux on the divertor plate of a fusion reactor is probably one of the most limiting constraints on its lifetime. The current heat flux profile on the outer divertor plate of a device like ITER is highly peaked with narrow profile. The peak heat flux can be as high as 30--40 MW/m 2 with full width at half maximum (FWHM) is in the order of a few centimeters. Sweeping the separatrix along the divertor plate is one of the options proposed to reduce the thermomechanical effects of this highly peaked narrow profile distribution. The effectiveness of the sweeping process is investigated parametrically for various design values. The optimum sweeping parameters of a particular heat load will depend on the design of the divertor plate as well as on the profile of such a heat load. In general, moving a highly peaked heat load results in substantial reduction of the thermomechanical effects on the divertor plate. 3 refs., 8 figs

  15. Upgraded divertor Thomson scattering system on DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Glass, F., E-mail: glassf@fusion.gat.com; Carlstrom, T. N.; Du, D.; Taussig, D. A.; Boivin, R. L. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); McLean, A. G. [Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94550 (United States)

    2016-11-15

    A design to extend the unique divertor Thomson scattering system on DIII-D to allow measurements of electron temperature and density in high triangularity plasmas is presented. Access to this region is selectable on a shot-by-shot basis by redirecting the laser beam of the existing divertor Thomson system inboard — beneath the lower floor using a moveable, high-damage threshold, in-vacuum mirror — and then redirecting again vertically. The currently measured divertor region remains available with this mirror retracted. Scattered light is collected from viewchords near the divertor floor using in-vacuum, high temperature optical elements and relayed through the port window, before being coupled into optical fiber bundles. At higher elevations from the floor, measurements are made by dynamically re-focusing the existing divertor system collection optics. Nd:YAG laser timing, analysis of the scattered light spectrum via polychromators, data acquisition, and calibration are all handled by existing systems or methods of the current multi-pulse Thomson scattering system. Existing filtered polychromators with 7 spectral channels are employed to provide maximum measurement breadth (T{sub e} in the range of 0.5 eV–2 keV, n{sub e} in the range of 5 × 10{sup 18}–1 × 10{sup 21} m{sup 3}) for both low T{sub e} in detachment and high T{sub e} measurement up beyond the separatrix.

  16. Toroidal asymmetries in divertor impurity influxes in NSTX

    Directory of Open Access Journals (Sweden)

    F. Scotti

    2017-08-01

    Full Text Available Toroidal asymmetries in divertor carbon and lithium influxes were observed in NSTX, due to toroidal differences in surface composition, tile leading edges, externally-applied three-dimensional (3D fields and toroidally-localized edge plasma modifications due to radio frequency heating. Understanding toroidal asymmetries in impurity influxes is critical for the evaluation of total impurity sources, often inferred from measurements with a limited toroidal coverage. The toroidally-asymmetric lithium deposition induced asymmetries in divertor lithium influxes. Enhanced impurity influxes at the leading edge of divertor tiles were the main cause of carbon toroidal asymmetries and were enhanced during edge localized modes. Externally-applied 3D fields led to strike point splitting and helical lobes observed in divertor impurity emission, but marginal changes to the toroidally-averaged impurity influxes. Power coupled to the scrape-off layer SOL plasma during radio frequency (RF heating of H-mode discharges enhanced impurity influxes along the non-axisymmetric divertor footprint of flux tubes connecting to plasma in front of the RF antenna.

  17. Radiation induced early delayed changes in mice brain: a 1h MRS and behavioral evaluation study

    International Nuclear Information System (INIS)

    Gupta, Mamta; Rana, Poonam; Haridas, Seenu; Manda, Kailash; Hemanth Kumar, B.S.; Khushu, Subash

    2014-01-01

    Radiation induced CNS injury can be classified as acute, early delayed and late delayed. Most of the studies suggest that acute injury is reversible whereas early delayed and late delayed injury is irreversible leading to metabolic and cognitive impairment. Extensive research has been carried out on cranial radiation induced early and late delayed changes, there are no reports on whole body radiation induced early and delayed changes. The present study was designed to observe early delayed effects of radiation during whole body radiation exposure. A total of 20 C57 male mice were divided in two groups of 10 animals each. One group was exposed to a dose of 5 Gy whole body radiation through Tele 60 Co irradiation facility with source operating at 2.496 Gy/min, while other group served as sham irradiated control. Behavioral and MR spectroscopy was carried out 3 months post irradiation. Behavioral parameters such as locomotor activity and working memory were evaluated first then followed by MR spectroscopy at 7T animal MRI system. For MRS, voxel was localised in the cortex-hippocampus region of mouse brain. MR spectra were acquired using PRESS sequence, FID was processed using LC model for quantitation. The data showed impaired cognitive functions and altered metabolite levels during early delayed phase of whole body radiation induced injury. In behavioural experiments, there was a significant impairment in the cognitive as well as exploratory functions at 3 months post irradiation in irradiated group as compared to controls. MRS results explained changes in mI, glutamine and glx levels in irradiated animals compared to controls. Altered mI level has been found to be associated with reduced cognitive abilities in many brain disorders including MCI and Alzheimer's disease. The findings of this study suggest that whole body radiation exposure may have long lasting effect on the cognitive performance. (author)

  18. Design study of ITER-like divertor target for DEMO

    International Nuclear Information System (INIS)

    Crescenzi, Fabio; Bachmann, C.; Richou, M.; Roccella, S.; Visca, E.; You, J.-H.

    2015-01-01

    Highlights: • ‘DEMO’ is a near-term Power Plant Conceptual Study (PPCS). • The ITER-like design concept represents a promising solution also for DEMO plasma facing units. • The optimization of PFUs aims to enhance the thermo-mechanical behaviour of the component. • The optimized geometry was evaluated by ITER SDC-IC criteria and in terms of low cycle fatigue (LCF). - Abstract: A near-term water-cooled target solution has to be evaluated together with the required technologies and its power exhaust limit under ‘DEMO’ conditions. The ITER-like design concept based on the mono-block technology using W as armour material and the CuCrZr-IG as structural material with an interlayer of pure copper represents a promising solution also for DEMO. This work reports the design study of an “optimized” ITER-like Water Cooled Divertor able to withstand a heat flux of 10 MW m"−"2, as requested for DEMO operating conditions. The optimization of plasma facing unit (PFU) aims to enhance the thermo-mechanical behaviour of the component by varying some geometrical parameters (monoblock size, interlayer thickness and, tube diameter and thickness). The optimization was performed by means of the multi-variable optimization algorithms using the FEM code ANSYS. The coolant hydraulic conditions (inlet pressure, temperature and velocity) were fixed for simplicity. This study is based on elastic analysis and 3 dimensional modelling. The resulting optimized geometry was evaluated on the basis of the ITER SDC-IC criteria and in terms of low cycle fatigue (LCF). The margin to the critical heat flux (CHF) was also estimated. Further design study (taking into account the effect of neutron radiation on the material properties) together with mock-up fabrication and high-heat-flux (HHF) tests are foreseen in next work programmes.

  19. Design study of ITER-like divertor target for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Crescenzi, Fabio, E-mail: fabio.crescenzi@enea.it [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Roma) (Italy); Bachmann, C. [EFDA, Power Plant Physics and Technology, Boltzmannstraße 2, 85748 Garching (Germany); Richou, M. [CEA, IRFM, F-13108 Saint Paul Lez Durance (France); Roccella, S.; Visca, E. [ENEA, Unità Tecnica Fusione, ENEA C. R. Frascati, via E. Fermi 45, 00044 Frascati (Roma) (Italy); You, J.-H. [Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany)

    2015-10-15

    Highlights: • ‘DEMO’ is a near-term Power Plant Conceptual Study (PPCS). • The ITER-like design concept represents a promising solution also for DEMO plasma facing units. • The optimization of PFUs aims to enhance the thermo-mechanical behaviour of the component. • The optimized geometry was evaluated by ITER SDC-IC criteria and in terms of low cycle fatigue (LCF). - Abstract: A near-term water-cooled target solution has to be evaluated together with the required technologies and its power exhaust limit under ‘DEMO’ conditions. The ITER-like design concept based on the mono-block technology using W as armour material and the CuCrZr-IG as structural material with an interlayer of pure copper represents a promising solution also for DEMO. This work reports the design study of an “optimized” ITER-like Water Cooled Divertor able to withstand a heat flux of 10 MW m{sup −2}, as requested for DEMO operating conditions. The optimization of plasma facing unit (PFU) aims to enhance the thermo-mechanical behaviour of the component by varying some geometrical parameters (monoblock size, interlayer thickness and, tube diameter and thickness). The optimization was performed by means of the multi-variable optimization algorithms using the FEM code ANSYS. The coolant hydraulic conditions (inlet pressure, temperature and velocity) were fixed for simplicity. This study is based on elastic analysis and 3 dimensional modelling. The resulting optimized geometry was evaluated on the basis of the ITER SDC-IC criteria and in terms of low cycle fatigue (LCF). The margin to the critical heat flux (CHF) was also estimated. Further design study (taking into account the effect of neutron radiation on the material properties) together with mock-up fabrication and high-heat-flux (HHF) tests are foreseen in next work programmes.

  20. A study on the fusion reactor - A study on the design feature of fusion reactor divertor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Jin [Chosun University, Kwangju (Korea, Republic of); Paek, Won Pil; Jang, Soon Hong [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Sim, Young Jae [Kyungsang University, Jinju (Korea, Republic of)

    1996-09-01

    The contents and scope of the project can be summarized as, - study on the trend of divertor design - study on characteristics of coolant materials - study on characteristics of divertor materials - study on the thermal analysis method of divertor design. 36 refs., 12 tabs., 16 figs. (author)

  1. Simulation of dense recombining divertor plasmas with a Navier endash Stokes neutral transport model

    International Nuclear Information System (INIS)

    Knoll, D.A.; McHugh, P.R.; Krasheninnikov, S.I.; Sigmar, D.J.

    1996-01-01

    A two-dimensional combined edge plasma Navier endash Stokes neutral transport model is presented for the simulation of dense recombining divertor plasmas. This model includes ions, electrons, and neutral atoms which undergo Coulomb collisions, electron impact ionization, ion endash neutral elastic collisions, three-body and radiative recombination, and neutral endash neutral collisions. The advanced fully implicit solution algorithm is briefly described and a variety of results on a model geometry are presented. It is shown that interesting neutral flow patterns can exist and that these flows can convect significant energy. A solution that ignores neutral endash neutral collisions is shown to be quantitatively different from one that includes neutral endash neutral collisions. Solutions are also shown to be sensitive to the plasma opacity for Lyman α radiation. copyright 1996 American Institute of Physics

  2. The effects of field reversal on the Alcator C-Mod divertor

    International Nuclear Information System (INIS)

    Hutchinson, I.H.; LaBombard, B.; Goetz, J.A.; Lipschultz, B.; McCracken, G.M.; Snipes, J.A.; Terry, J.L.

    1995-01-01

    Imbalances between the inboard and outboard legs of the single null divertor in tokamak Alcator C-Mod are observed to reverse when the direction of the toroidal field is reversed. These imbalances are measured by embedded probes in the target plates, tomographic reconstructions of bolometry and line radiation, and visible imaging. Density imbalances of about a factor of ten at the targets are observed at moderate density, decreasing as the density is raised until they are almost balanced. The data indicate that the electron pressure is not imbalanced, thus arguing against momentum imbalance as the cause of these drift-induced effects. Instead, power flux imbalance caused by E r ''and'' B convection, and enhanced by radiation, is suggested as the underlying cause. (Author)

  3. Exploring the engineering limit of heat flux of a W/RAFM divertor target for fusion reactors

    Science.gov (United States)

    Mao, X.; Fursdon, M.; Chang, X. B.; Zhang, J. W.; Liu, P.; Ellwood, G.; Qian, X. Y.; Qin, S. J.; Peng, X. B.; Barrett, T. R.; Liu, P.

    2018-06-01

    The design and development of a fusion reactor divertor plasma facing component (PFC) is one of the many challenging issues on the road to commercial use of fusion energy. The divertor PFC is expected to exhaust steady state heat loads in the region of 10 MW m‑2 while keeping temperatures and thermo-mechanical stresses in its structure within the allowable limits. For ITER (International Thermo-Nuclear Experimental Reactor) a water cooled W/CuCrZr divertor PFC concept has been developed. However, this concept is not necessarily assured for use in future fusion reactors mainly because the neutron radiation dose would be at least an order magnitude higher, resulting in limited thermo-mechanical performance and considerably more activated waste products. In the present study, a water cooled divertor PFC using reduced activation ferritic-martensitic (RAFM) steel as the heat sink pipe has been designed with pressurised water reactor-like cooling conditions (pressure of 15.5 MPa, velocity of 10–20 m s‑1 and temperature of 300 °C). The PFC is made up of a number of rectangular tungsten tiles, each with an inner circular hole (so-called monoblocks), joined onto a RAFM steel pipe with copper interlayers. The thermo-mechanical performance of the PFC has been studied in detail. The heat transfer coefficient between the RAFM pipe inner surface and the water was calculated using published correlations. Geometric parameters and water velocity were optimized with finite element (FE) thermal analysis, to achieve acceptable temperatures in the structure given the target exhaust heat load of 10 MW m‑2. Under this heat load and the optimised thermal design parameters, the structure of the PFC was further assessed by mechanical analysis. We find that under these conditions the RAFM steel pipe experiences cyclic plasticity, and fails the common linear elastic ratchetting (3 Sm) rule. Nevertheless, the designed W/RAFM divertor PFU can withstand 10 MW m‑2 heat load, albeit

  4. Effects of acute sublethal gamma radiation exposure on aggressive behavior in male mice: A dose-response study

    International Nuclear Information System (INIS)

    Maier, D.M.; Landauer, M.R.

    1989-01-01

    The resident-intruder paradigm was used to assess the effects of gamma radiation (0, 3, 5, 7 Gray [Gy] cobalt-60) on aggressive offensive behavior in resident male mice over a 3-month period. The defensive behavior of nonirradiated intruder mice was also monitored. A dose of 3 Gy had no effect on either the residents' offensive behavior or the defensive behavior of the intruders paired with them. Doses of 5 and 7 Gy produced decreases in offensive behavior of irradiated residents during the second week postirradiation. The nonirradiated intruders paired with these animals displayed decreases in defensive behavior during this time period, indicating a sensitivity to changes in the residents' behavior. After the third week postirradiation, offensive and defensive behavior did not differ significantly between irradiated mice and sham-irradiated controls. This study suggests that sublethal doses of radiation can temporarily suppress aggressive behavior but have no apparent permanent effect on that behavior

  5. Delayed behavioral dysfunctions following exposure to ionising radiation: role of neurogenesis

    International Nuclear Information System (INIS)

    Haridas, Seenu; Kumar, Mayank; Manda, Kailash

    2014-01-01

    Being a terminally differentiated organ, the brain has been considered to be a radioresistant one. Traditionally, delayed radiation-induced CNS damage was hypothesized as chiefly attributable to impaired vascular endothelial system and neuroinflammatory glial cell populations. In the recent decades, preclinical studies have focused on the hippocampal dentate gyrus, one of two discrete sites of the brain where adult neurogenesis takes place. Neurogenesis, in such area of the brain takes place throughout the adulthood and makes the brain highly vulnerable to the radiation. Recent investigations, including our own reports indicated that radiation ablates hippocampal neurogenesis, alters neuronal function, and induces neuroinflammation. Since the hippocampus is involved in learning and memory, behavioral adaptation and HPA axis regulation, damage by radiation leads to severe behavioral and cognitive dysfunctions. The present study aimed at evaluating the delayed effects of gamma-irradiation on the cognitive and affective functions, which were further corroborated to changes in neurogenesis. C57BL/6J mice were exposed to whole body irradiation as well as cranial irradiation by gamma-rays at different sub-lethal doses. The behavioral tests, consisting spontaneous motor activity, open field test, novel object recognition test, forced swim test and Morris water maze were performed at 1 month and 5 months post-exposure. Neurogenic potential was evaluated using flow-cytometry (FC) and immuno-histo-chemistry (IHC). The results indicated the significant changes in the affective and cognitive functions at delayed time points of radiation exposure. Profound alteration in the anxiety and depressive phenotype was observed following irradiation. Additionally, both long term and short term memory functions were disrupted, which were attributable to changes in the neurogenic potential as reported in the terms of BrdU positive cells using FC and IHC. Present investigation clearly

  6. Aberrations in preliminary design of ITER divertor impurity influx monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kitazawa, Sin-iti, E-mail: kitazawa.siniti@jaea.go.jp [Naka Fusion Institute, Japan Atomic Energy Agency, JAEA, Naka 311-0193 (Japan); Ogawa, Hiroaki [Naka Fusion Institute, Japan Atomic Energy Agency, JAEA, Naka 311-0193 (Japan); Katsunuma, Atsushi; Kitazawa, Daisuke [Core Technology Center, Nikon Corporation, Yokohama 244-8533 (Japan); Ohmori, Keisuke [Customized Products Business Unit, Nikon Corporation, Mito 310-0843 (Japan)

    2015-12-15

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • The spot diagrams were suppressed within the core of receiving fiber. • The aberration of DIM is suppressed in the preliminary design. - Abstract: Divertor impurity influx monitor for ITER (DIM) is a diagnostic system that observes light from nuclear fusion plasma directly. This system is affected by various aberrations because it observes light from the fan-array chord near the divertor in the ultraviolet–near infrared wavelength range. The aberrations should be suppressed to the extent possible to observe the light with very high spatial resolution. In the preliminary design of DIM, spot diagrams were suppressed within the core of the receiving fiber's cross section, and the resulting spatial resolutions satisfied the design requirements.

  7. The simple map for a single-null divertor tokamak

    International Nuclear Information System (INIS)

    Punjabi, A.; Verma, A.; Boozer, A.

    1996-01-01

    We present the simple map for a single-null divertor tokamak. The simple map is an area-preserving map based on the idea that magnetic field lines are a single-degree-of-freedom time-dependent Hamiltonian system, and that the basic features of such systems near the X-point are generic. We obtain the properties of this map and the resulting footprints of field lines on the divertor plate. These include the width of the stochastic layer, the edge safety factor, the area of the footprint and the amount of magnetic flux diverted. We give the safety factor profile, the average and median values of strike angles, lengths and the Liapunov exponents. We describe how the effects of magnetic perturbations can be included in the simple map. We show how the map can be applied to the problem of the determination of heat flux on the divertor plate in tokamaks. (Author)

  8. Charge exchange in a divertor plasma with excited particles

    International Nuclear Information System (INIS)

    Krasheninnikov, S.I.; Lisitsa, V.S.; Pigarov, A.Y.

    1988-01-01

    A model is constructed for the dynamics of neutral atoms and multicharged ions in a tokamak plasma. The influence of cascade excitation on charge exchange and ionization is taken into account. The effective rates of the resonant charge exchange of a proton with a hydrogen atom, the nonresonant charge exchange of a helium atom with a proton, and that of an α particle with atomic hydrogen are calculated as functions of the parameters of the divertor plasma in a tokamak. The charge exchange H + +He→H+He + can represent a significant fraction (∼30%) of the total helium ionization rate. Incorporating the charge exchange of He 2+ with atomic hydrogen under the conditions prevailing in the divertor plasma of the INTOR reactor can lead to substantial He 2+ →He + conversion and thereby reduce the sputtering of the divertor plates by helium ions

  9. Development of divertor pumping system with superpermeable membrane

    International Nuclear Information System (INIS)

    Nakamura, Y.; Ohyabu, N.; Suzuki, H.; Nakahara, Y.; Livshits, A.; Notkin, M.; Alimov, V.; Busnyuk, A.

    2000-01-01

    A new divertor pumping system with superpermeable membranes of group Va-metals (Nb, V) is now under research and development. Properties of membrane pumping were investigated with the use of a plasma device simulating divertor plasma conditions. The deposition of metal (Fe) and non-metal (C) impurities on the membrane upstream surface results in a degradation of plasma driven superpermeation at the membrane temperature T m m ≥800 deg. C. The same temperature effect on superpermeation is observed at sputtering of membrane surface by energetic plasma ions. In addition, the first application of the membrane pumping to fusion devices has been carried out and a deuterium pumping through the membrane was demonstrated under the conditions of divertor plasma in the JFT-2M tokamak

  10. A survey of problems in divertor and edge plasma theory

    International Nuclear Information System (INIS)

    Boozer, A.; Braams, B.; Weitzner, H.; Hazeltine, R.; Houlberg, W.; Oktay, E.; Sadowski, W.; Wootton, A.

    1992-01-01

    Theoretical physics problems related to divertor design are presented, organized by the region in which they occur. Some of the open questions in edge physics are presented from a theoretician's point of view. After a cursory sketch of the fluid models of the edge plasma and their numerical realization, the following topics are taken up: time-dependent problems, non-axisymmetric effects, anomalous transport in the scrape-off layer, edge kinetic theory, sheath effects and boundary conditions in divertors, electric field effects, atomic and molecular data issues, impurity transport in the divertor region, poloidally localized power dissipation (MARFEs and dense gas targets), helium ash removal, and neutral transport. The report ends with a summary of selected problems of particular significance and a brief bibliography of survey articles and related conference proceedings

  11. Aberrations in preliminary design of ITER divertor impurity influx monitor

    International Nuclear Information System (INIS)

    Kitazawa, Sin-iti; Ogawa, Hiroaki; Katsunuma, Atsushi; Kitazawa, Daisuke; Ohmori, Keisuke

    2015-01-01

    Highlights: • Divertor impurity influx monitor for ITER (DIM) is procured by JADA. • DIM is designed to observe light from nuclear fusion plasma directly. • DIM is under preliminary design phase. • The spot diagrams were suppressed within the core of receiving fiber. • The aberration of DIM is suppressed in the preliminary design. - Abstract: Divertor impurity influx monitor for ITER (DIM) is a diagnostic system that observes light from nuclear fusion plasma directly. This system is affected by various aberrations because it observes light from the fan-array chord near the divertor in the ultraviolet–near infrared wavelength range. The aberrations should be suppressed to the extent possible to observe the light with very high spatial resolution. In the preliminary design of DIM, spot diagrams were suppressed within the core of the receiving fiber's cross section, and the resulting spatial resolutions satisfied the design requirements.

  12. Design and characterization of a prototype divertor viewing infrared video bolometer for NSTX-U

    Energy Technology Data Exchange (ETDEWEB)

    Eden, G. G. van; Morgan, T. W. [Dutch Institute for Fundamental Energy Research, 5612 AJ Eindhoven (Netherlands); Reinke, M. L.; Gray, T. K.; Lore, J. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Peterson, B. J.; Mukai, K. [National Institute for Fusion Science, Toki 509-5292 (Japan); Delgado-Aparicio, L. F.; Jaworski, M. A. [Princeton Plasma Physics Laboratory, P.O. Box 451, Princeton, New Jersey 08543 (United States); Sano, R. [National Institutes for Quantum and Radiological Science and Technology, Naka 311-0193 (Japan); Pandya, S. N. [Institute for Plasma Research, Bhat Village, Gandhinagar, 382428 Gujarat (India)

    2016-11-15

    The InfraRed Video Bolometer (IRVB) is a powerful tool to measure radiated power in magnetically confined plasmas due to its ability to obtain 2D images of plasma emission using a technique that is compatible with the fusion nuclear environment. A prototype IRVB has been developed and installed on NSTX-U to view the lower divertor. The IRVB is a pinhole camera which images radiation from the plasma onto a 2.5 μm thick, 9 × 7 cm{sup 2} Pt foil and monitors the resulting spatio-temporal temperature evolution using an IR camera. The power flux incident on the foil is calculated by solving the 2D+time heat diffusion equation, using the foil’s calibrated thermal properties. An optimized, high frame rate IRVB, is quantitatively compared to results from a resistive bolometer on the bench using a modulated 405 nm laser beam with variable power density and square wave modulation from 0.2 Hz to 250 Hz. The design of the NSTX-U system and benchtop characterization are presented where signal-to-noise ratios are assessed using three different IR cameras: FLIR A655sc, FLIR A6751sc, and SBF-161. The sensitivity of the IRVB equipped with the SBF-161 camera is found to be high enough to measure radiation features in the NSTX-U lower divertor as estimated using SOLPS modeling. The optimized IRVB has a frame rate up to 50 Hz, high enough to distinguish radiation during edge-localized-modes (ELMs) from that between ELMs.

  13. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety on dental hygienist

    International Nuclear Information System (INIS)

    Han, Eun Ok; Jun, Sung Hee

    2008-01-01

    The objective of this study is to draw an educational plant for reducing the probability of troubles caused by radiation for dental hygienists who are the major applicants of radiation equipments used in dental offices. This study investigated the knowledge and self-efficacy, which is the major variable that affects the attitude and behavior, on the radiation safety that is an educational approach. Also, this study obtained following results from a survey for 25 days from June 15, 2008 that was applied for 225 dental hygienists worked at dental offices and clinics in the area of Youngnam in order to verify the relationship between such variables. The average scores for the knowledge, attitude, and behavior were 54.28±16.33, 87.93±9.75, and 59.85±14.76, respectively. Also, the average score of the self-efficacy was 72.88±8.60. In the knowledge level for the radiation safety, ‘a case that prepares personal dosimeters’, ‘a case that establishes protection facilities’, ‘a case that presents 6⁓10 dental hygienists’, ‘a case that presents radiological technologists’, and ‘a case that is a general hospital’ represented high values. In the attitude level for the radiation safety, ‘a case who is a married person’, ‘a case that prepares personal dosimeters’, and ‘a case that is a general hospital’ showed high values. In the behavior level for the radiation safety, ‘a case that shows a career in dental hygienist or radiographic for 6⁓10 years’, ‘a case that attends radiation safety education’, ‘a case that establishes protection facilities’ showed high values. Also, in the self-efficacy level, ‘a case that who has a high education level more than graduate school education’ and ‘a case that establishes protection facilities’ represented high values. In the relationship between the knowledge, attitude, behavior, and self-efficacy for the radiation safety, it showed statistically significant differences in this

  14. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety on dental hygienist

    Energy Technology Data Exchange (ETDEWEB)

    Han, Eun Ok; Jun, Sung Hee [Daegu Health College, Daegu (Korea, Republic of)

    2008-11-15

    The objective of this study is to draw an educational plant for reducing the probability of troubles caused by radiation for dental hygienists who are the major applicants of radiation equipments used in dental offices. This study investigated the knowledge and self-efficacy, which is the major variable that affects the attitude and behavior, on the radiation safety that is an educational approach. Also, this study obtained following results from a survey for 25 days from June 15, 2008 that was applied for 225 dental hygienists worked at dental offices and clinics in the area of Youngnam in order to verify the relationship between such variables. The average scores for the knowledge, attitude, and behavior were 54.28±16.33, 87.93±9.75, and 59.85±14.76, respectively. Also, the average score of the self-efficacy was 72.88±8.60. In the knowledge level for the radiation safety, ‘a case that prepares personal dosimeters’, ‘a case that establishes protection facilities’, ‘a case that presents 6⁓10 dental hygienists’, ‘a case that presents radiological technologists’, and ‘a case that is a general hospital’ represented high values. In the attitude level for the radiation safety, ‘a case who is a married person’, ‘a case that prepares personal dosimeters’, and ‘a case that is a general hospital’ showed high values. In the behavior level for the radiation safety, ‘a case that shows a career in dental hygienist or radiographic for 6⁓10 years’, ‘a case that attends radiation safety education’, ‘a case that establishes protection facilities’ showed high values. Also, in the self-efficacy level, ‘a case that who has a high education level more than graduate school education’ and ‘a case that establishes protection facilities’ represented high values. In the relationship between the knowledge, attitude, behavior, and self-efficacy for the radiation safety, it showed statistically significant differences in this

  15. Thermomechanical characterization of joints for blanket and divertor application processed by electrochemical plating

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Wolfgang; Lorenz, Julia; Konys, Jürgen; Basuki, Widodo; Aktaa, Jarir

    2016-11-01

    Highlights: • Electroplating is a relevant technology for brazing of blanket and divertor parts. • Tungsten, Eurofer and steel joints successfully fabricated. • Reactive interlayers improve adherence and reduce failure risks. • Qualification of joints performed by thermo-mechanical testing and aging. • Shear strength of joints comparable with conventionally brazing of steels. - Abstract: Fusion technology requires in the fields of first wall and divertor development reliable and adjusted joining processes of plasma facing tungsten to heat sinks or blanket structures. The components to be bonded will be fabricated from tungsten, steel or other alloys like copper. The parts have to be joined under functional and structural aspects considering the metallurgical interactions of alloys to be assembled and the filler materials. Application of conventional brazing showed lacks ranging from bad wetting of tungsten up to embrittlement of fillers and brazing zones. Thus, the deposition of reactive interlayers and filler components, e.g. Ni, Pd or Cu was initiated to overcome these metallurgical restrictions and to fabricate joints with aligned mechanical behavior. This paper presents results concerning the joining of tungsten, Eurofer and stainless steel for blanket and divertor application by applying electroplating technology. Metallurgical and mechanical characterization by shear testing were performed to analyze the joints quality and application limits in dependence on testing temperature between room temperature and 873 K and after thermal aging of up to 2000 h. The tested interlayers Ni and Pd enhanced wetting and enabled the processing of reliable joints with a shear strength of more than 200 MPa at RT.

  16. Divertor plate concept with carbon based armour for NET

    International Nuclear Information System (INIS)

    Moons, F.; Howard, R.; Kneringer, G.; Stickler, R.

    1989-01-01

    A series of tests has been performed on simulated divertor elements for NET at the JET neutral beam injector test bed. The test section consisted of a water cooled main structure, the surface of which was protected with a carbon based armour in the form of tiles. The scope of these was to study the thermal behaviour of mechanically attached tiles with the use of an intermediate soft carbon layer to improve the thermal contact under divertor relevant conditions. (author). 4 refs.; 4 figs.; 1 tab

  17. Turbulence studies in tokamak boundary plasmas with realistic divertor geometry

    International Nuclear Information System (INIS)

    Xu, X.Q.; Cohen, R.H.; Porter, G.D.; Rognlien, T.; Ryutov, D.D.; Myra, J.R.; D'Ippolito, D.A.; Moyer, R.; Groebner, R.J.

    2001-01-01

    Results are presented from the 3D nonlocal electromagnetic turbulence code BOUT and the linearized shooting code BAL for studies of turbulence in tokamak boundary plasmas and its relationship to the L-H transition, in a realistic divertor plasma geometry. The key results include: (1) the identification of the dominant resistive X-point mode in divertor geometry and (2) turbulence suppression in the L-H transition by shear in the ExB drift speed, ion diamagnetism and nite polarization. Based on the simulation results, a parameterization of the transport is given that includes the dependence on the relevant physical parameters. (author)

  18. Turbulence studies in tokamak boundary plasmas with realistic divertor geometry

    International Nuclear Information System (INIS)

    Xu, X.Q.; Cohen, R.H.; Por, G.D. ter; Rognlien, T.D.; Ryutov, D.D.; Myra, J.R.; D'Ippolito, D.A.; Moyer, R.; Groebner, R.J.

    1999-01-01

    Results are presented from the 3D nonlocal electromagnetic turbulence code BOUT and the linearized shooting code BAL for studies of turbulence in tokamak boundary plasmas and its relationship to the L-H transition, in a realistic divertor plasma geometry. The key results include: (1) the identification of the dominant resistive X-point mode in divertor geometry and (2) turbulence suppression in the L-H transition by shear in the E x B drift speed, ion diamagnetism and finite polarization. Based on the simulation results, a parameterization of the transport is given that includes the dependence on the relevant physical parameters. (author)

  19. An analytic model for flow reversal in divertor plasmas

    International Nuclear Information System (INIS)

    Cooke, P.I.H.; Prinja, A.K.

    1987-04-01

    An analytic model is developed and used to study the phenomenon of flow reversal which is observed in two-dimensional simulations of divertor plasmas. The effect is shown to be caused by the radial spread of neutral particles emitted from the divertor target which can lead to a strong peaking of the ionization source at certain radial locations. The results indicate that flow reversal over a portion of the width of the scrape-off layer is inevitable in high recycling conditions. Implications for impurity transport and particle removal in reactors are discussed

  20. Radiation-induced increases in sensitivity of cataleptic behavior to haloperidol: possible involvement of prostaglandins

    International Nuclear Information System (INIS)

    Joseph, J.A.; Kandasamy, S.B.; Hunt, W.A.; Dalton, T.K.; Stevens, S.

    1988-01-01

    The effects of radiation exposure on haloperidol-induced catalepsy were examined in order to determine whether elevated prostaglandins, through an action on dopaminergic autoreceptors, could be involved in the radiation-induced increase in the potency of this neuroleptic. Cataleptic behavior was examined in animals irradiated with various doses of gamma photons (1-150 Gy) and pretreated with a subthreshold dose of haloperidol (0.1 mg/kg). This approach was chosen to maximize any synergistic effects of radiation and haloperidol. After irradiation with doses less than or equal to 30 Gy, the combined treatment of haloperidol and radiation produced catalepsy, whereas neither treatment alone had an effect. This observed catalepsy could be blocked with prior administration of indomethacin, a prostaglandin synthesis inhibitor. Animals exposed to doses of radiation less than or equal to 50 Gy and no haloperidol, however, displayed apparent catalepsy. This effect was also antagonized by indomethacin. Prostaglandins can induce catalepsy and when administered in subthreshold doses along with subthreshold doses of haloperidol, catalepsy was observed. In order to assess a possible action of prostaglandins and radiation on dopaminergic activity, the functioning of striatal dopaminergic autoreceptors was examined by determining the effects of varying concentrations of haloperidol on the K+-evoked release of dopamine from striatal slices obtained from parallel groups of animals treated as above. Results indicated that sensitivity to haloperidol increased (higher K+-evoked dopamine release) in slices from irradiated or prostaglandin-treated animals and that this increase in sensitivity was blocked by indomethacin

  1. Engineering design of a toroidal divertor for the EBT-S fusion device. Final report, Phase II. EBT-S divertor project

    International Nuclear Information System (INIS)

    Mai, L.P.; Malick, F.S.

    1981-01-01

    The mechanical, structural, thermal, electrical, and vacuum design of a magnetic toroidal divertor system for the Elmo Bumpy Torus (EBT-S) is presented. The EBT-S is a toroidal magnetic fusion device located at the ORNL that operates under steady state conditions. The engineering of the divertor was performed during the second of three phases of a program aimed at the selection, design, fabrication, and installation of a magnetic divertor for EBT-S. The magnetic analysis of the toroidal divertor was performed during Phase I of the program and has been reported in a separate document. In addition to the details of the divertor design, the modest modifications that are required to the EBT-S device and facility to accommodate the divertor system are presented

  2. Critical heat flux acoustic detection: Methods and application to ITER divertor vertical target monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, X., E-mail: xavier.courtois@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Escourbiac, F. [ITER Organization, Route de Vinon sur Verdon, F-13115 Saint-Paul-Lez-Durance (France); Richou, M.; Cantone, V. [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Constans, S. [AREVA-NP, Le Creusot (France)

    2013-10-15

    Actively cooled plasma facing components (PFCs) have to exhaust high heat fluxes from plasma radiation and plasma–wall interaction. Critical heat flux (CHF) event may occur in the cooling channel due to unexpected heat loading or operational conditions, and has to be detected as soon as possible. Therefore it is essential to develop means of monitoring based on precursory signals providing an early detection of this destructive phenomenon, in order to be able to stop operation before irremediable damages appear. Capabilities of CHF early detection based on acoustic techniques on PFC mock-ups cooled by pressurised water were already demonstrated. This paper addresses the problem of the detection in case of flow rate reduction and of flow dilution resulting from multiple plasma facing units (PFU) which are hydraulically connected in parallel, which is the case of ITER divertor. An experimental study is launched on a dedicated mock-up submitted to heat loads up to the CHF. It shows that the measurement of the acoustic waves, generated by the cooling phenomena, allows the CHF detection in conditions similar to that of the ITER divertor, with a reasonable number of sensors. The paper describes the mock-ups and the tests sequences, and comments the results.

  3. Thermal Analysis of the Divertor Primary Heat Transfer System Piping During the Gas Baking Process

    International Nuclear Information System (INIS)

    Yoder, Graydon L. Jr.; Harvey, Karen; Ferrada, Juan J.

    2011-01-01

    A preliminary analysis has been performed examining the temperature distribution in the Divertor Primary Heat Transfer System (PHTS) piping and the divertor itself during the gas baking process. During gas baking, it is required that the divertor reach a temperature of 350 C. Thermal losses in the piping and from the divertor itself require that the gas supply temperature be maintained above that temperature in order to ensure that all of the divertor components reach the required temperature. The analysis described in this report was conducted in order to estimate the required supply temperature from the gas heater.

  4. OEDGE modeling of plasma contamination efficiency of Ar puffing from different divertor locations in EAST

    Science.gov (United States)

    Pengfei, ZHANG; Ling, ZHANG; Zhenwei, WU; Zong, XU; Wei, GAO; Liang, WANG; Qingquan, YANG; Jichan, XU; Jianbin, LIU; Hao, QU; Yong, LIU; Juan, HUANG; Chengrui, WU; Yumei, HOU; Zhao, JIN; J, D. ELDER; Houyang, GUO

    2018-04-01

    Modeling with OEDGE was carried out to assess the initial and long-term plasma contamination efficiency of Ar puffing from different divertor locations, i.e. the inner divertor, the outer divertor and the dome, in the EAST superconducting tokamak for typical ohmic plasma conditions. It was found that the initial Ar contamination efficiency is dependent on the local plasma conditions at the different gas puff locations. However, it quickly approaches a similar steady state value for Ar recycling efficiency >0.9. OEDGE modeling shows that the final equilibrium Ar contamination efficiency is significantly lower for the more closed lower divertor than that for the upper divertor.

  5. Emotional and Behavioral Functioning After Conformal Radiation Therapy for Pediatric Ependymoma

    International Nuclear Information System (INIS)

    Willard, Victoria W.; Conklin, Heather M.; Boop, Frederick A.; Wu, Shengjie; Merchant, Thomas E.

    2014-01-01

    Purpose: The standard of care for pediatric patients with ependymoma involves postoperative radiation therapy. Prior research suggests that conformal radiation therapy (CRT) is associated with relative sparing of cognitive and academic functioning, but little is known about the effect of CRT on emotional and behavioral functioning. Methods and Materials: A total of 113 patients with pediatric ependymoma underwent CRT using photons as part of their enrollment on an institutional trial. Patients completed annual evaluations of neurocognitive functioning during the first 5 years after CRT. Emotional and behavioral functioning was assessed via the Child Behavior Checklist. Results: Before CRT, emotional and behavioral functioning were commensurate with those of the normative population and within normal limits. After 5 years, means remained within normal limits but were significantly below the normative mean. Linear mixed models revealed a significant increase in attention problems over time. These problems were associated with age at diagnosis/CRT, tumor location, and extent of resection. A higher-than-expected incidence of school problems was present at all assessment points after baseline. Conclusions: The use of photon CRT for ependymoma is associated with relatively stable emotional and behavioral functioning during the first 5 years after treatment. The exception is an increase in attention problems. Results suggest that intervening earlier in the survivorship period—during the first year posttreatment—may be beneficial

  6. Emotional and Behavioral Functioning After Conformal Radiation Therapy for Pediatric Ependymoma

    Energy Technology Data Exchange (ETDEWEB)

    Willard, Victoria W.; Conklin, Heather M. [Department of Psychology, St. Jude Children' s Research Hospital, Memphis, Tennessee (United States); Boop, Frederick A. [Department of Surgery, St. Jude Children' s Research Hospital, Memphis, Tennessee (United States); Department of Neurosurgery, Semmes-Murphey Neurologic and Spine Institute, Memphis, Tennessee (United States); Wu, Shengjie [Department of Biostatistics, St. Jude Children' s Research Hospital, Memphis, Tennessee (United States); Merchant, Thomas E., E-mail: thomas.merchant@stjude.org [Division of Radiation Oncology, St. Jude Children' s Research Hospital, Memphis, Tennessee (United States)

    2014-03-15

    Purpose: The standard of care for pediatric patients with ependymoma involves postoperative radiation therapy. Prior research suggests that conformal radiation therapy (CRT) is associated with relative sparing of cognitive and academic functioning, but little is known about the effect of CRT on emotional and behavioral functioning. Methods and Materials: A total of 113 patients with pediatric ependymoma underwent CRT using photons as part of their enrollment on an institutional trial. Patients completed annual evaluations of neurocognitive functioning during the first 5 years after CRT. Emotional and behavioral functioning was assessed via the Child Behavior Checklist. Results: Before CRT, emotional and behavioral functioning were commensurate with those of the normative population and within normal limits. After 5 years, means remained within normal limits but were significantly below the normative mean. Linear mixed models revealed a significant increase in attention problems over time. These problems were associated with age at diagnosis/CRT, tumor location, and extent of resection. A higher-than-expected incidence of school problems was present at all assessment points after baseline. Conclusions: The use of photon CRT for ependymoma is associated with relatively stable emotional and behavioral functioning during the first 5 years after treatment. The exception is an increase in attention problems. Results suggest that intervening earlier in the survivorship period—during the first year posttreatment—may be beneficial.

  7. Electrical resistance behavior with gamma radiation dose in bulk carbon nanostrutured samples

    International Nuclear Information System (INIS)

    Lage, J.; Leyva, A.; Pinnera, I.; Desdin, L. F.; Abreu, Y.; Cruz, C. M.; Leyva, D.; Toledo, C.

    2013-01-01

    The aim of this paper is to study the effects of 60 Co gamma radiation on the electrical resistance and V-I characteristic of bulk carbon nano structured samples obtained by electric arc discharge in water method. Images of pristine samples obtained with scanning electron, and the results in graphical form of the electrical characterization of irradiated samples are presented in the text. It was observed that the electrical resistance vs. dose behavior shows an initial increment reaching the maximum at approximately 135 kGy, followed by a drop of the resistance values. These behaviors are associated with the progressive generation of radiation induced defects in the sample, whose number increases to reach saturation at 135 kGy. From this dose, defects could lead to cross-links between different nano structures present in the sample conducting to a gradually drop in electrical resistance. The measured V-I curves show that, increasing exposure to the 60 Co gamma radiation, the electrical properties of the studied samples transit from a semiconductor towards a predominantly metallic behavior. These results were compared with those obtained for a sample of graphite powder irradiated under the same conditions. (Author)

  8. Effects of fetal microwave radiation exposure on offspring behavior in mice

    International Nuclear Information System (INIS)

    Zhang Yanchun; Li Zhihui; Gao Yan; Zhang Chenggang

    2015-01-01

    The recent rapid development of electronic communication techniques is resulting in a marked increase in exposure of humans to electromagnetic fields (EMFs). This has raised public concerns about the health hazards of long-term environmental EMF exposure for fetuses and children. Some studies have suggested EMF exposure in children could induce nervous system disorders. However, gender-dependent effects of microwave radiation exposure on cognitive dysfunction have not previously been reported. Here we investigated whether in utero exposure to 9.417-GHz microwave throughout gestation (Days 3.5–18) affected behavior, using the open field test (OFT), elevated-plus maze (EPM), tail suspension test (TST), forced swimming test (FST) and Morris water maze (MWM). We found that mice showed less movement in the center of an open field (using the OFT) and in an open arm (using the EPM) after in utero exposure to 9.417-GHz radiation, which suggested that the mice had increased anxiety-related behavior. Mice demonstrated reduced immobility in TST and FST after in utero exposure to 9.417-GHz radiation, which suggested that the mice had decreased depression-related behavior. From the MWM test, we observed that male offspring demonstrated decreased learning and memory, while females were not affected in learning and memory, which suggested that microwaves had gender-dependent effects. In summary, we have provided the first experimental evidence of microwaves inducing gender-dependent effects. (author)

  9. Feedback system for divertor impurity seeding based on real-time measurements of surface heat flux in the Alcator C-Mod tokamak

    Science.gov (United States)

    Brunner, D.; Burke, W.; Kuang, A. Q.; LaBombard, B.; Lipschultz, B.; Wolfe, S.

    2016-02-01

    Mitigation of the intense heat flux to the divertor is one of the outstanding problems in fusion energy. One technique that has shown promise is impurity seeding, i.e., the injection of low-Z gaseous impurities (typically N2 or Ne) to radiate and dissipate the power before it arrives to the divertor target plate. To this end, the Alcator C-Mod team has created a first-of-its-kind feedback system to control the injection of seed gas based on real-time surface heat flux measurements. Surface thermocouples provide real-time measurements of the surface temperature response to the plasma heat flux. The surface temperature measurements are inputted into an analog computer that "solves" the 1-D heat transport equation to deliver accurate, real-time signals of the surface heat flux. The surface heat flux signals are sent to the C-Mod digital plasma control system, which uses a proportional-integral-derivative (PID) algorithm to control the duty cycle demand to a pulse width modulated piezo valve, which in turn controls the injection of gas into the private flux region of the C-Mod divertor. This paper presents the design and implementation of this new feedback system as well as initial results using it to control divertor heat flux.

  10. Modeling results for a linear simulator of a divertor

    International Nuclear Information System (INIS)

    Hooper, E.B.; Brown, M.D.; Byers, J.A.; Casper, T.A.; Cohen, B.I.; Cohen, R.H.; Jackson, M.C.; Kaiser, T.B.; Molvik, A.W.; Nevins, W.M.; Nilson, D.G.; Pearlstein, L.D.; Rognlien, T.D.

    1993-01-01

    A divertor simulator, IDEAL, has been proposed by S. Cohen to study the difficult power-handling requirements of the tokamak program in general and the ITER program in particular. Projections of the power density in the ITER divertor reach ∼ 1 Gw/m 2 along the magnetic fieldlines and > 10 MW/m 2 on a surface inclined at a shallow angle to the fieldlines. These power densities are substantially greater than can be handled reliably on the surface, so new techniques are required to reduce the power density to a reasonable level. Although the divertor physics must be demonstrated in tokamaks, a linear device could contribute to the development because of its flexibility, the easy access to the plasma and to tested components, and long pulse operation (essentially cw). However, a decision to build a simulator requires not just the recognition of its programmatic value, but also confidence that it can meet the required parameters at an affordable cost. Accordingly, as reported here, it was decided to examine the physics of the proposed device, including kinetic effects resulting from the intense heating required to reach the plasma parameters, and to conduct an independent cost estimate. The detailed role of the simulator in a divertor program is not explored in this report

  11. Modelling of radial electric field profile for different divertor configurations

    International Nuclear Information System (INIS)

    Rozhansky, V; Kaveeva, E; Voskoboynikov, S; Counsell, G; Kirk, A; Meyer, H; Coster, D; Conway, G; Schirmer, J; Schneider, R

    2006-01-01

    The impact of divertor configuration on the structure of the radial electric field has been simulated by the B2SOLPS5.0 transport fluid code. It is shown that the change in the parallel flows in the scrape-off layer, which are transported through the separatrix due to turbulent viscosity and diffusivity, should result in variation of the radial electric field and toroidal rotation in the separatrix vicinity. The modelling predictions are compared with the measurements of the radial electric field for the low field side equatorial mid-plane of ASDEX Upgrade in lower, upper and double-null (DN) divertor configurations. The parallel (toroidal) flows in the scrape-off layer and mechanisms for their formation are analysed for different geometries. It is demonstrated that a spike in the electric field exists at the high field side equatorial mid-plane in the connected DN divertor configuration. Its origin is connected with different potential drops between the separatrix vicinity and divertor plates in the two disconnected scrape-off layers, while the separatrix should be at almost the same potential. The spike might be important for additional turbulent suppression

  12. Plasma/neutral gas transport in divertors and limiters

    International Nuclear Information System (INIS)

    Gierszewski, P.J.

    1983-09-01

    The engineering design of the divertor and first wall region of fusion reactors requires accurate knowledge of the energies and particle fluxes striking these surfaces. Simple calculations indicate that approx. 10 MW/m 2 heat fluxes and approx. 1 cm/yr erosion rates are possible, but there remain fundamental physics questions that bear directly on the engineering design. The purpose of this study was to treat hydrogen plasma and neutral gas transport in divertors and pumped limiters in sufficient detail to answer some of the questions as to the actual conditions that will be expected in fusion reactors. This was accomplished in four parts: (1) a review of relevant atomic processes to establish the dominant interactions and their data base; (2) a steady-state coupled O-D model of the plasma core, scrape-off layer and divertor exhaust to determine gross modes of operation and edge conditions; (3) a 1-D kinetic transport model to investigate the case of collisionless divertor exhaust, including non-Maxwellian ions and neutral atoms, highly collisional electrons, and a self-consistent electric field; and (4) a 3-D Monte Carlo treatment of neutral transport to correctly account for geometric effects

  13. Electron and molecular ion collisions relevant to divertor plasma

    International Nuclear Information System (INIS)

    Takagi, H.

    2005-01-01

    We introduce the concept of the multi-channel quantum defect theory (MQDT) and show the outline of the MQDT newly extended to include the dissociative states. We investigate some molecular processes relevant to the divertor plasma by using the MQDT: the dissociative recombination, dissociative excitation, and rotation-vibrational transition in the hydrogen molecular ion and electron collisions. (author)

  14. Modular He-cooled divertor for power plant application

    International Nuclear Information System (INIS)

    Diegele, Eberhard; Kruessmann, R.; Malang, S.; Norajitra, P.; Rizzi, G.

    2003-01-01

    Gas cooled divertor concepts are regarded as a suitable option for fusion power plants because of an increased thermal efficiency for power conversion systems and the use of a coolant compatible with all blanket systems. A modular helium cooled divertor concept is proposed with an improved heat transfer. The concept employs small tiles made of tungsten and brazed to a finger-like structure made of Mo-alloy (TZM). Design goal was a heat flux of at least 15 MW/m 2 and a minimum temperature of the structure of 600 deg.C. The divertor has to survive a number of cycles (100-1000) between operating temperature and room temperature even for the steady state operation assumed. Thermo-hydraulic design requirements for the concepts include to keep the pumping power below 10% of the thermal power to the divertor plates, and simultaneously achieving a heat transfer coefficient in excess of 60 kW/m 2 K. Inelastic stress analysis indicates that design allowable stress limits on primary and secondary (thermal) stresses as required by the ITER structural design criteria are met even under conservative assumptions. Finally, critical issues for future development are addressed

  15. Lifetime analysis for fusion reactor first walls and divertor plates

    International Nuclear Information System (INIS)

    Horie, T.; Tsujimura, S.; Minato, A.; Tone, T.

    1987-01-01

    Lifetime analysis of fusion reactor first walls and divertor plates is performed by (1) a one-dimensional analytical plate model, and (2) a two-dimensional elastic-plastic finite element method. Life-limiting mechanisms and the limits of applicability for these analysis methods are examined. Structural design criteria are also discussed. (orig.)

  16. Mechanical Design of the NSTX Liquid Lithium Divertor

    Energy Technology Data Exchange (ETDEWEB)

    R. Ellis, R. Kaita, H. Kugel, G. Paluzzi, M. Viola and R. Nygren

    2009-02-19

    The Liquid Lithium Divertor (LLD) on NSTX will be the first test of a fully-toroidal liquid lithium divertor in a high-power magnetic confinement device. It will replace part of the lower outboard divertor between a specified inside and outside radius, and ultimately provide a lithium surface exposed to the plasma with enough depth to absorb a significant particle flux. There are numerous technical challenges involved in the design. The lithium layer must be as thin as possible, and maintained at a temperature between 200 and 400 degrees Celsius to minimize lithium evaporation. This requirement leads to the use of a thick copper substrate, with a thin stainless steel layer bonded to the plasma-facing surface. A porous molybdenum layer is then plasma-sprayed onto the stainless steel, to provide a coating that facilitates full wetting of the surface by the liquid lithium. Other challenges include the design of a robust, vacuumcompatible heating and cooling system for the LLD. Replacement graphite tiles that provided the proper interface between the existing outer divertor and the LLD also had to be designed, as well as accommodation for special LLD diagnostics. This paper describes the mechanical design of the LLD, and presents analyses showing the performance limits of the LLD.

  17. Enhancing the DEMO divertor target by interlayer engineering

    International Nuclear Information System (INIS)

    Barrett, T.R.; McIntosh, S.C.; Fursdon, M.; Hancock, D.; Timmis, W.; Coleman, M.; Rieth, M.; Reiser, J.

    2015-01-01

    Highlights: • The European ‘near-term’ DEMO forsees a water-cooled divertor. • Divertor targets typically use an interlayer between the armour and structure. • Engineering the properties of the interlayer can yield large gains in performance. • A response surface based design search and optimisation method is used. • A new design passes linear-elastic code rules up to applied heat flux of 18 MW/m"2. - Abstract: A robust water-cooled divertor target plate solution for DEMO has to date remained elusive. Common to all contemporary concepts is an interlayer at the boundary between the tungsten armour and the cooling structure. In this paper we show by design optimisation that an effectively designed interlayer can produce dramatic gains in power handling. By engineering the interlayer as part of the design study, it is found that divertor performance is enhanced by either a low conductivity ‘Thermal Break’ interlayer or an ‘Ultra-Compliant’ interlayer. For a 10 MW/m"2 surface heat flux we find that a thermal conductivity of 15 W/mK and elastic modulus of 1 GPa are effective. A design is proposed which passes linear-elastic code rules up to an applied heat flux of 18 MW/m"2.

  18. Enhancing the DEMO divertor target by interlayer engineering

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, T.R., E-mail: tom.barrett@ccfe.ac.uk [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); McIntosh, S.C.; Fursdon, M.; Hancock, D.; Timmis, W.; Coleman, M. [CCFE, Culham Science Centre, Oxfordshire OX14 3DB (United Kingdom); Rieth, M.; Reiser, J. [Karlsruhe Institute for Technology, IMF-I, D-7602 Karlsruhe (Germany)

    2015-10-15

    Highlights: • The European ‘near-term’ DEMO forsees a water-cooled divertor. • Divertor targets typically use an interlayer between the armour and structure. • Engineering the properties of the interlayer can yield large gains in performance. • A response surface based design search and optimisation method is used. • A new design passes linear-elastic code rules up to applied heat flux of 18 MW/m{sup 2}. - Abstract: A robust water-cooled divertor target plate solution for DEMO has to date remained elusive. Common to all contemporary concepts is an interlayer at the boundary between the tungsten armour and the cooling structure. In this paper we show by design optimisation that an effectively designed interlayer can produce dramatic gains in power handling. By engineering the interlayer as part of the design study, it is found that divertor performance is enhanced by either a low conductivity ‘Thermal Break’ interlayer or an ‘Ultra-Compliant’ interlayer. For a 10 MW/m{sup 2} surface heat flux we find that a thermal conductivity of 15 W/mK and elastic modulus of 1 GPa are effective. A design is proposed which passes linear-elastic code rules up to an applied heat flux of 18 MW/m{sup 2}.

  19. Taming the plasma-material interface with the snowflake divertor.

    Energy Technology Data Exchange (ETDEWEB)

    Soukhanovskii, V A

    2015-04-24

    Experiments in several tokamaks have provided increasing support for the snowflake configuration as a viable tokamak heat exhaust concept. This white paper summarizes the snowflake properties predicted theoretically and studied experimentally, and identifies outstanding issues to be resolved in existing and future facilities before the snowflake divertor can qualify for the reactor interface.

  20. Plasma shape control calculations for BPX divertor design

    International Nuclear Information System (INIS)

    Strickler, D.J.; Neilson, G.H.; Jardin, S.C.; Pomphrey, N.

    1991-01-01

    The Burning Plasma Experiment (BPX) divertor is to be capable of withstanding heat loads corresponding to ignited operation and 500 MW of fusion power for a current rise time and flattop lasting several seconds. The poloidal field (PF), diagnostic, and feedback equilibrium control systems must provide precise X-point position control in order to sweep the separatrices across the divertor target surface and optimally distribute the heat loads. A control matrix MHD equilibrium code, BEQ, and the Tokamak Simulation Code (TSC) are used to compute preprogrammed double-null (DN) divertor sweep trajectories that maximize sweep distance while simultaneously satisfying a set of strict constraints: minimum lengths of the field lines between the X-point and strike points, minimum spacing between the inboard plasma edge and the limiter, maximum spacing between the outboard plasma edge and the ICRF antennas, minimum safety factor, and linked poloidal flux. A sequence of DN diverted equilibria and a consistent TSC fiducial discharge simulation are used in evaluating the performance of the BPX divertor shape and possible modifications. 5 refs., 10 figs

  1. Mechanical Design of the NSTX Liquid Lithium Divertor

    International Nuclear Information System (INIS)

    Ellis, R.; Kaita, R.; Kugel, H.; Paluzzi, G.; Viola, M.; Nygren, R.

    2009-01-01

    The Liquid Lithium Divertor (LLD) on NSTX will be the first test of a fully-toroidal liquid lithium divertor in a high-power magnetic confinement device. It will replace part of the lower outboard divertor between a specified inside and outside radius, and ultimately provide a lithium surface exposed to the plasma with enough depth to absorb a significant particle flux. There are numerous technical challenges involved in the design. The lithium layer must be as thin as possible, and maintained at a temperature between 200 and 400 degrees Celsius to minimize lithium evaporation. This requirement leads to the use of a thick copper substrate, with a thin stainless steel layer bonded to the plasma-facing surface. A porous molybdenum layer is then plasma-sprayed onto the stainless steel, to provide a coating that facilitates full wetting of the surface by the liquid lithium. Other challenges include the design of a robust, vacuum compatible heating and cooling system for the LLD. Replacement graphite tiles that provided the proper interface between the existing outer divertor and the LLD also had to be designed, as well as accommodation for special LLD diagnostics. This paper describes the mechanical design of the LLD, and presents analyses showing the performance limits of the LLD.

  2. Operational limits on WEST inertial divertor sector during the early phase experiment

    Science.gov (United States)

    Firdaouss, M.; Corre, Y.; Languille, P.; Greuner, H.; Autissier, E.; Desgranges, C.; Guilhem, D.; Gunn, J. P.; Lipa, M.; Missirlian, M.; Pascal, J.-Y.; Pocheau, C.; Richou, M.; Tsitrone, E.

    2016-02-01

    The primary goal of the WEST project is to be a test bed to characterize the fatigue and lifetime of ITER-like W divertor components subjected to relevant thermal loads. During the first phase of exploitation (S2 2016), these components (W monoblock plasma facing unit—W-PFU) will be installed in conjunction with graphite components (G-PFU). Since the G-PFU will not be actively cooled, it is necessary to ensure the expected pulse duration allows the W-PFU to reach its steady state without overheating the G-PFU assembly structure or the embedded stainless-steel diagnostics. High heat flux tests were performed at the GLADIS facility to assess the thermal behavior of the G-PFU. Some operational limits based on plasma parameters were determined. It was found that it is possible to operate at an injected power such that the maximal incident heat flux on the lower divertor is 10 MW m-2 for the required pulse length.

  3. Operational limits on WEST inertial divertor sector during the early phase experiment

    International Nuclear Information System (INIS)

    Firdaouss, M; Corre, Y; Languille, P; Autissier, E; Desgranges, C; Guilhem, D; Gunn, J P; Lipa, M; Missirlian, M; Pascal, J-Y; Pocheau, C; Richou, M; Tsitrone, E; Greuner, H

    2016-01-01

    The primary goal of the WEST project is to be a test bed to characterize the fatigue and lifetime of ITER-like W divertor components subjected to relevant thermal loads. During the first phase of exploitation (S2 2016), these components (W monoblock plasma facing unit—W-PFU) will be installed in conjunction with graphite components (G-PFU). Since the G-PFU will not be actively cooled, it is necessary to ensure the expected pulse duration allows the W-PFU to reach its steady state without overheating the G-PFU assembly structure or the embedded stainless-steel diagnostics. High heat flux tests were performed at the GLADIS facility to assess the thermal behavior of the G-PFU. Some operational limits based on plasma parameters were determined. It was found that it is possible to operate at an injected power such that the maximal incident heat flux on the lower divertor is 10 MW m −2 for the required pulse length. (paper)

  4. Manufacturing and joining technologies for helium cooled divertors

    International Nuclear Information System (INIS)

    Aktaa, J.; Basuki, W.W.; Weber, T.; Norajitra, P.; Krauss, W.; Konys, J.

    2014-01-01

    Highlights: • The manufacturing and joining technologies developed at KIT for helium cooled divertors are reviewed and critically discussed. • Various technologies have been pursued and further developed aiming divertor components with very high quality and sufficient reliability. • Very promising routes have been found for which however still R and D works are necessary. • Technologies developed are also useful for other divertor and even blanket concepts, particularly those with tungsten armor. - Abstract: In the helium cooled (HC) divertor, developed at KIT for a fusion power plant, tungsten has been selected as armor as well as structural material due to its crucial properties: high melting point, very low sputtering yield, good thermal conductivity, high temperature strength, low thermal expansion and low activation. Thereby the armor tungsten is attached to the structural tungsten by thermally conductive joint. Due to the brittleness of tungsten at low temperatures its use as structural material is limited to the high temperature part of the component and a structural joint to the reduced activation ferritic martensitic steel EUROFER97 is foreseen. Hence, to realize the selected hybrid material concept reliable tungsten–steel and tungsten–tungsten joints have been developed and will be reported in this paper. In addition, the modular design of the HC divertor requires tungsten armor tiles and tungsten structural thimbles to be manufactured in high numbers with very high quality. Due to the high strength and low temperature brittleness of tungsten special manufacturing techniques need to be developed for the production of parts with no cavities inside and/or surface flaws. The main achievement in developing the respective manufacturing technologies will be presented and discussed. To achieve the objectives mentioned above various manufacturing and joining technologies are pursued. Their later applicability depends on the level of development

  5. Radiation

    International Nuclear Information System (INIS)

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  6. Elastic-plastic-creep analysis of brazed carbon-carbon/OFHC divertor tile concepts for TPX

    International Nuclear Information System (INIS)

    Chin, E.; Reis, E.E.

    1995-01-01

    The 7.5 MW/m 2 heat flux requirements for the TPX divertor necessitate the use of high conductivity carbon-carbon (C-C) tiles that are brazed to annealed copper (OFHC) coolant tubes. Significant residual stresses are developed in the C-C tiles during the braze process due to large differences in the thermal expansion coefficients between these materials. Analyses which account for only the elastic-plastic strains developed in the OFHC tube may not accurately characterize the behavior of the tube during brazing. The elevated temperature creep behavior of the copper coolant tubes intuitively should reduce the calculated residual stresses in the C-C tiles. Two divertor tile concepts, the monoblock and the archblock, were analyzed for residual stress using 2-D finite element analysis for elastic-plastic-creep behavior of the OFHC tube during an assumed braze cooldown cycle. The results show that the inclusion of elevated temperature creep effects decrease the calculated residual stresses by only about 10% when compared to those analyses in which only elastic-plastic behavior of the OFHC is accounted for. The primary reason that creep effects at higher temperatures are not more significant is due to the low yield stress and nearly flat-top stress-strain curve of annealed OFHC. Since high temperature creep plays less of a role in the residual stress levels than previously thought, future scoping studies can be done in an elastic-plastic analysis with confidence that the stresses will be within approximately 10% of an elastic-plastic-creep analysis

  7. Optimization and limitations of known DEMO divertor concepts

    International Nuclear Information System (INIS)

    Reiser, Jens; Rieth, Michael

    2012-01-01

    Highlights: ► Limitations of the materials. ► Improved H 2 O cooled divertor. ► Improved He cooled divertor. - Abstract: In this work we will introduce and discuss improvements for two types of DEMO divertors based on known designs: (i) gas cooled designs and (ii) liquid coolant concepts. In a first step, the advantages and disadvantages of gas cooling as well as the necessity of a jet impingement to increase the heat transfer coefficients will be discussed. Further discussion deals with the pros and cons of liquid coolant concepts, like for example, liquid metal or water cooling. Thereafter, we will present two rather contrary DEMO divertor concepts which are based on today's knowledge on refractory materials science, fabrication and joining technology. The first improved concept uses water flowing through steel pipes, typically made of Eurofer steel. It is well known that using Eurofer at low temperatures is critical due to its severe embrittlement under neutron irradiation. Here we make a proposal how it could be possible to use the Eurofer steel anyway: the solution could consist in a limited operation period followed by an annealing cycle at 550 °C for a few hours during any maintenance shut down phases. The second design is based on the known helium cooling concept using jet impingement. Drawbacks of the actual He-cooled divertor design are small scale parts as well as the necessary high helium inlet temperature of about 600–800 °C which leads to the question: How can we deal with such high helium temperatures? This paper shows a solution for large scale components as well as a new thermal management for the helium outlet gas that we call ‘cooling of the coolant’. Both concepts are discussed in terms of materials selection due to material limits and joining technology with a special focus on the material issue using already existing and available materials.

  8. Initial development of the DIII–D snowflake divertor control

    Science.gov (United States)

    Kolemen, E.; Vail, P. J.; Makowski, M. A.; Allen, S. L.; Bray, B. D.; Fenstermacher, M. E.; Humphreys, D. A.; Hyatt, A. W.; Lasnier, C. J.; Leonard, A. W.; McLean, A. G.; Maingi, R.; Nazikian, R.; Petrie, T. W.; Soukhanovskii, V. A.; Unterberg, E. A.

    2018-06-01

    Simultaneous control of two proximate magnetic field nulls in the divertor region is demonstrated on DIII–D to enable plasma operations in an advanced magnetic configuration known as the snowflake divertor (SFD). The SFD is characterized by a second-order poloidal field null, created by merging two first-order nulls of the standard divertor configuration. The snowflake configuration has many magnetic properties, such as high poloidal flux expansion, large plasma-wetted area, and additional strike points, that are advantageous for divertor heat flux management in future fusion reactors. However, the magnetic configuration of the SFD is highly-sensitive to changes in currents within the plasma and external coils and therefore requires complex magnetic control. The first real-time snowflake detection and control system on DIII–D has been implemented in order to stabilize the configuration. The control algorithm calculates the position of the two nulls in real-time by locally-expanding the Grad–Shafranov equation in the divertor region. A linear relation between variations in the poloidal field coil currents and changes in the null locations is then analytically derived. This formulation allows for simultaneous control of multiple coils to achieve a desired SFD configuration. It is shown that the control enabled various snowflake configurations on DIII–D in scenarios such as the double-null advanced tokamak. The SFD resulted in a 2.5×  reduction in the peak heat flux for many energy confinement times (2–3 s) without any adverse effects on core plasma performance.

  9. Plasma facing components integration studies for the WEST divertor

    Energy Technology Data Exchange (ETDEWEB)

    Ferlay, Fabien, E-mail: fabien.ferlay@cea.fr; Missirlian, Marc; Guilhem, Dominique; Firdaouss, Mehdi; Richou, Marianne; Doceul, Louis; Faisse, Frédéric; Languille, Pascal; Larroque, Sébastien; Martinez, André; Proust, Maxime; Louison, Céphise; Jeanne, Florian; Saille, Alain; Samaille, Frank; Verger, Jean-Marc; Bucalossi, Jérôme

    2015-10-15

    Highlights: • The divertor PFU integration has been studied regarding existing environment. • Magnetic, electric, thermal, hydraulic, mechanical loads and assembly are considered. - Abstract: In the context of the Tokamak Tore-Supra evolution, the CEA aims at transforming it into a test bench for ITER actively cooled tungsten (ACW) plasma facing components (PFC). This project named WEST (Tungsten Environment in Steady state Tokamak) is especially focused on the divertor target. The modification of the machine, by adding two axisymmetric divertors will make feasible an H-mode with an X-point close to the lower divertor. This environment will allow exposing the divertor ACW components up to 20 MW/m{sup 2} heat flux during long pulse. These specifications are well suited to test the ITER-like ACW target elements, respecting the ITER design. One challenge in such machine evolution is to integrate components in an existing vacuum vessel in order to obtain the best achievable performance. This paper deals with the design integration of ITER ACW target elements into the WEST environment considering magnetic, electric, thermal and mechanical loads. The feasibility of installation and maintenance has to be strongly considered as these PFC could be replaced several times. The ports size allows entering a 30° sector of pre-installed tungsten targets which will be plugged as quickly and easily as possible. The main feature of steady state operation is the active cooling, which leads to have many embedded cooling channels and bulky pipes on the PFC module including many connections and sealings between vacuum and water channels. The 30° sector design is now finalized regarding the ITER ACW elements specifications. No major modifications are expected.

  10. New achievements of the Divertor Test Platform programme for the ITER divertor remote maintenance R and D

    International Nuclear Information System (INIS)

    Damiani, C.; Baldi, L.; Galbiati, L.; Irving, M.; Lorenzelli, L.; Micciche, G.; Muro, L.; Nucci, S.; Varocchi, G.; Poggianti, A.; Fermani, G.; Maisonnier, D.; Palmer, J.; Martin, E.; Friconneau, J.P.; Gravez, P.; Takeda, N.

    2001-01-01

    The divertor assembly for the ITER fusion reactor consists of a number of rail mounted cassettes (54 now in ITER FEAT) located in the bottom region of the vacuum vessel. These cassettes shall be removed/installed remotely during the life of the reactor by means of specific devices. To demonstrate and optimise the feasibility of the in-vessel maintenance process the Divertor Test Platform (DTP) has been established at the ENEA Research Centre in Brasimone, Italy, as a major part of the large ITER R and D project L7. A first set of tests has been already carried out and reported during 1998, when the basic feasibility of the divertor replacement was demonstrated. In the present period (January 1999-July 2000), new activities, including both site tests and other 'external' R and D works, have been carried out in order to refine and improve the ITER divertor maintenance scenario. These include the study of abnormal maintenance operations and of possible handling equipment failure and its consequences; the procurement and testing of new sub-systems (e.g. a force reflection manipulator arm), and the development of remote handling techniques including a virtual reality system. Following a short description of the DTP, this paper reports on the new results and achievements, draws the relevant conclusions, and finally discusses future activities

  11. Optimized tokamak power exhaust with double radiative feedback in ASDEX Upgrade

    Science.gov (United States)

    Kallenbach, A.; Bernert, M.; Eich, T.; Fuchs, J. C.; Giannone, L.; Herrmann, A.; Schweinzer, J.; Treutterer, W.; the ASDEX Upgrade Team

    2012-12-01

    A double radiative feedback technique has been developed on the ASDEX Upgrade tokamak for optimization of power exhaust with a standard vertical target divertor. The main chamber radiation is measured in real time by a subset of three foil bolometer channels and controlled by argon injection in the outer midplane. The target heat flux is in addition controlled by nitrogen injection in the divertor private flux region using either a thermoelectric sensor or the scaled divertor radiation obtained by a bolometer channel in the outer divertor. No negative interference of the two radiation controllers has been observed so far. The combination of main chamber and divertor radiative cooling extends the operational space of a standard divertor configuration towards high values of P/R. Pheat/R = 14 MW m-1 has been achieved so far with nitrogen seeding alone as well as with combined N + Ar injection, with the time-averaged divertor peak heat flux below 5 MW m-2. Good plasma performance can be maintained under these conditions, namely H98(y,2) = 1 and βN = 3.

  12. Comparisons of physical and chemical sputtering in high density divertor plasmas with the Monte Carlo Impurity (MCI) transport model

    International Nuclear Information System (INIS)

    Evans, T.E.; Loh, Y.S.; West, W.P.; Finkenthal, D.F.

    1997-11-01

    The MCI transport model was used to compare chemical and physical sputtering for a DIII-D divertor plasma near detachment. With physical sputtering alone the integrated carbon influx was 8.4 x 10 19 neutral/s while physical plus chemical sputtering produced an integrated carbon influx of 1.7 x 10 21 neutrals/s. The average carbon concentration in the computational volume increased from 0.012% with only physical sputtering to 0.182% with both chemical and physical sputtering. This increase in the carbon inventory produced more radiated power which is in better agreement with experimental measurements

  13. An FPGA-based bolometer for the MAST-U Super-X divertor

    Energy Technology Data Exchange (ETDEWEB)

    Lovell, Jack, E-mail: jack.lovell@durham.ac.uk [Durham University, South Road, Durham DH1 3LE (United Kingdom); Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Naylor, Graham; Field, Anthony [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Drewelow, Peter [MPI für Plasmaphysik, Greifswald (Germany); Sharples, Ray [Durham University, South Road, Durham DH1 3LE (United Kingdom); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-11-15

    A new resistive bolometer system has been developed for MAST-Upgrade. It will measure radiated power in the new Super-X divertor, with millisecond time resolution, along 16 vertical and 16 horizontal lines of sight. The system uses a Xilinx Zynq-7000 series Field-Programmable Gate Array (FPGA) in the D-TACQ ACQ2106 carrier to perform real time data acquisition and signal processing. The FPGA enables AC-synchronous detection using high performance digital filtering to achieve a high signal-to-noise ratio and will be able to output processed data in real time with millisecond latency. The system has been installed on 8 previously unused channels of the JET vertical bolometer system. Initial results suggest good agreement with data from existing vertical channels but with higher bandwidth and signal-to-noise ratio.

  14. Characterizing the behavior of scattered radiation in multi-energy x-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sossin, Artur, E-mail: artur.sossin@gmail.com [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Rebuffel, V.; Tabary, J. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France); Létang, J.M.; Freud, N. [Univ Lyon, INSA-Lyon, Université Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Centre Léon Bérard, CREATIS UMR 5220 U1206, F-69373 Lyon (France); Verger, L. [CEA-LETI MINATEC Grenoble, F-38054 Grenoble (France)

    2017-04-01

    Scattered radiation results in various undesirable effects in medical diagnostics, non-destructive testing (NDT) and security x-ray imaging. Despite numerous studies characterizing this phenomenon and its effects, the knowledge of its behavior in the energy domain remains limited. The present study aims at summarizing some key insights on scattered radiation originating from the inspected object. In addition, various simulations and experiments with limited collimation on both simplified and realistic phantoms were conducted in order to study scatter behavior in multi-energy x-ray imaging. Results showed that the spectrum shape of the scatter component can be considered preserved in the first approximation across the image plane for various acquisition geometries and phantoms. The variations exhibited by the scatter spectrum were below 10% for most examined cases. Furthermore, the corresponding spectrum shape proved to be also relatively invariant for different experimental angular projections of one of the examined phantoms. The observed property of scattered radiation can potentially lead to the decoupling of spatial and energy scatter components, which can in turn enable speed ups in scatter simulations and reduce the complexity of scatter correction.

  15. Effect of sun radiation on the thermal behavior of distribution transformer

    International Nuclear Information System (INIS)

    Hajidavalloo, Ebrahim; Mohamadianfard, Mohamad

    2010-01-01

    Performance and life of oil-immersed distribution transformers are strongly dependent on the oil temperature. Transformers, working in regions with high temperature and high solar radiation, usually suffer from excessive heat in summers which results in their early failures. In this paper, the effect of sun radiation on the transformer was investigated by using experimental and analytical methods. Transformer oil temperature was measured in two different modes, with and without sun shield. Effects of different parameters such as direct and indirect solar radiation on the thermal behavior of the transformer were mathematically modeled and the results were compared with experimental findings. Agreements between the experimental and numerical results show that the model can reasonably predict thermal behavior of the transformer. It was found that a sun shield has an important effect on the oil temperature reduction in summer which could be as high as 7 deg. C depending on the load ratio. The amount of temperature reduction by sun shield reduces as the load ratio of transformer increases. By installing a sun shield and reducing oil temperature, transformer life could be increased up to 24% in average.

  16. Divertor remote handling for DEMO: Concept design and preliminary FMECA studies

    Energy Technology Data Exchange (ETDEWEB)

    Carfora, D., E-mail: dario.carfora@gmail.com [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland); Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); ENEA/CREATE/Università degli studi Napoli Federico II, 80125 Napoli (Italy); Di Gironimo, G. [ENEA/CREATE/Università degli studi Napoli Federico II, 80125 Napoli (Italy); Järvenpää, J. [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland); Huhtala, K. [Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); Määttä, T.; Siuko, M. [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland)

    2015-10-15

    Highlights: • Concept design of the RH system for the DEMO fusion power plant. • Divertor mover: hydraulic telescopic boom concept design. • An alternative solution to ITER rack and pinion divertor mover (CMM). • Divertor cassettes end effector studies. • FMECA studies started on the DEMO divertor mover. - Abstract: The paper describes a concept design of a remote handling (RH) system for replacing divertor cassettes and cooling pipes in future DEMO fusion power plant. In DEMO reactor design important considerations are the reactor availability and reliable maintenance operations. The proposed divertor mover is a hydraulic telescopic boom driven from the transportation cask through the maintenance tunnel of the reactor. The boom is divided in three sections and it is driving an end-effector in order to perform the scheduled operations of maintenance inside the vacuum vessel. Two alternative designs of the end effector to grip and manipulate the divertor cassette are presented in this work. Both concepts are hydraulically actuated, based on ITER previous studies. The divertor cassette end-effector consists of a lifting arm linked to the divertor mover, a tilting plate, a cantilever arm and a hook-plate. Taking advantage of the ITER RH background and experience, the proposed hydraulic RH system is compared with the rack and pinion system currently designed for ITER and is an object of simulations at Divertor Test Platform (DTP2) in VTT's Labs of Tampere, Finland. Pros and cons will be put in evidence.

  17. Preliminary concept design of the divertor remote handling system for DEMO power plant

    Energy Technology Data Exchange (ETDEWEB)

    Carfora, D., E-mail: dario.carfora@gmail.com [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland); Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); ENEA/CREATE/University of Naples Federico II, 80125 Naples (Italy); Di Gironimo, G. [ENEA/CREATE/University of Naples Federico II, 80125 Naples (Italy); Järvenpää, J. [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland); Huhtala, K. [Tampere University of Technology, Korkeakoulunkatu 6, 33720 Tampere (Finland); Määttä, T.; Siuko, M. [VTT Technical Research Centre of Finland, P.O. Box 1300, FI-33101 Tampere (Finland)

    2014-11-15

    Highlights: • Concept design of the RH system for the DEMO fusion power plant. • Divertor Mover: Hydraulic telescopic boom concept design. An alternative solution to ITER rack and pinion divertor mover (CMM). • Divertor cassettes end effector studies. • Transportation cask conceptual studies and logistic. - Abstract: This paper is based on the remote maintenance system project (WPRM) for the demonstration fusion power reactor (DEMO). Following ITER, DEMO aims to confirm the capability of generating several hundred of MW of net electricity by 2050. The main objective of these activities is to develop an efficient and reliable remote handling (RH) system for replacing the divertor cassettes. This paper presents the preliminary results of the concept design of the divertor RH system. The proposed divertor mover is a hydraulic telescopic boom driven from the transportation cask through the maintenance tunnel of the reactor. The boom is divided in three sections of 4 m each, and it is driving an end-effector in order to perform the scheduled operations of maintenance inside the vacuum vessel. Two alternative design of the end effector to grip and manipulate the divertor cassette are also presented in this work. Both the concepts are hydraulically actuated, basing on the ITER previous studies. The divertor cassette end-effector consists of a lifting arm linked to the divertor mover, a tilting plate, a cantilever arm and a hook-plate. The main objective of this paper is to illustrate the feasibility of DEMO divertor remote maintenance operations.

  18. The control of divertor carbon erosion/redeposition in the DIII-D tokamak

    International Nuclear Information System (INIS)

    Whyte, D.G.; West, W.P.; Wong, C.P.C.

    2001-01-01

    The DIII-D tokamak has demonstrated an operational scenario where the graphite-covered divertor is free of net erosion. Reduction of divertor carbon erosion is accomplished using a low temperature (detached) divertor plasma that eliminates physical sputtering. Likewise, the carbon source rate arising from chemical erosion is found to be very low in the detached divertor. Near strikepoint regions, the rate of carbon deposition is ∼3 cm/burn-year, with a corresponding hydrogenic codeposition rate >1kg/m 2 /burn-year; rates both problematic for steady-state fusion reactors. The carbon net deposition rate in the divertor is consistent with carbon arriving from the core plasma region. Carbon influx from the main wall is measured to be relatively large in the high-density detached regime and is of sufficient magnitude to account for the deposition rate in the divertor. Divertor redeposition is therefore determined by non-divertor erosion and transport. Despite the success in reducing divertor erosion on DIII-D with detachment, no significant reduction is found in the core plasma carbon density, illustrating the importance of non-divertor erosion and the complex coupling between erosion/redeposition and impurity plasma transport. (author)

  19. Estimation of peak heat flux onto the targets for CFETR with extended divertor leg

    International Nuclear Information System (INIS)

    Zhang, Chuanjia; Chen, Bin; Xing, Zhe; Wu, Haosheng; Mao, Shifeng; Luo, Zhengping; Peng, Xuebing; Ye, Minyou

    2016-01-01

    Highlights: • A hypothetical geometry is assumed to extend the outer divertor leg in CFETR. • Density scan SOLPS simulation is done to study the peak heat flux onto target. • Attached–detached regime transition in out divertor occurs at lower puffing rate. • Unexpected delay of attached–detached regime transition occurs in inner divertor. - Abstract: China Fusion Engineering Test Reactor (CFETR) is now in conceptual design phase. CFETR is proposed as a good complement to ITER for demonstrating of fusion energy. Divertor is a crucial component which faces the plasmas and handles huge heat power for CFETR and future fusion reactor. To explore an effective way for heat exhaust, various methods to reduce the heat flux to divertor target should be considered for CFETR. In this work, the effect of extended out divertor leg on the peak heat flux is studied. The magnetic configuration of the long leg divertor is obtained by EFIT and Tokamak Simulation Code (TSC), while a hypothetical geometry is assumed to extend the out divertor leg as long as possible inside vacuum vessel. A SOLPS simulation is performed to study peak heat flux of the long leg divertor for CFETR. D 2 gas puffing is used and increasing of the puffing rate means increase of plasma density. Both peak heat flux onto inner and outer targets are below 10 MW/m 2 is achieved. A comparison between the peak heat flux between long leg and conventional divertor shows that an attached–detached regime transition of out divertor occurs at lower gas puffing gas puffing rate for long leg divertor. While for the inner divertor, even the configuration is almost the same, the situation is opposite.

  20. Estimation of peak heat flux onto the targets for CFETR with extended divertor leg

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Chuanjia; Chen, Bin [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Xing, Zhe [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Wu, Haosheng [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Mao, Shifeng, E-mail: sfmao@ustc.edu.cn [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Luo, Zhengping; Peng, Xuebing [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Ye, Minyou [School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2016-11-01

    Highlights: • A hypothetical geometry is assumed to extend the outer divertor leg in CFETR. • Density scan SOLPS simulation is done to study the peak heat flux onto target. • Attached–detached regime transition in out divertor occurs at lower puffing rate. • Unexpected delay of attached–detached regime transition occurs in inner divertor. - Abstract: China Fusion Engineering Test Reactor (CFETR) is now in conceptual design phase. CFETR is proposed as a good complement to ITER for demonstrating of fusion energy. Divertor is a crucial component which faces the plasmas and handles huge heat power for CFETR and future fusion reactor. To explore an effective way for heat exhaust, various methods to reduce the heat flux to divertor target should be considered for CFETR. In this work, the effect of extended out divertor leg on the peak heat flux is studied. The magnetic configuration of the long leg divertor is obtained by EFIT and Tokamak Simulation Code (TSC), while a hypothetical geometry is assumed to extend the out divertor leg as long as possible inside vacuum vessel. A SOLPS simulation is performed to study peak heat flux of the long leg divertor for CFETR. D{sub 2} gas puffing is used and increasing of the puffing rate means increase of plasma density. Both peak heat flux onto inner and outer targets are below 10 MW/m{sup 2} is achieved. A comparison between the peak heat flux between long leg and conventional divertor shows that an attached–detached regime transition of out divertor occurs at lower gas puffing gas puffing rate for long leg divertor. While for the inner divertor, even the configuration is almost the same, the situation is opposite.

  1. Design and Analysis of the Cryopump for the DIII-D Upper Divertor

    International Nuclear Information System (INIS)

    Reis, E.E.; Baxi, C.B.; Bozek, A.S.

    1999-01-01

    A cryocondensation pump for the upper inboard divertor on DIII-D is to be installed in the vacuum vessel in the fall of 1999. The cryopump removes neutral gas particles from the divertor and prevents recycling to the plasma. This pump is designed for a pumping speed of 18,000 ell/s at 0.4 mTorr. The cryopump is toroidally continuous to minimize inductive voltages and avoid electrical breakdown during disruptions. The cryopump consists of a 25 mm Inconel tube cooled by liquid helium and is surrounded by nitrogen cooled shields. A segmented ambient temperature radiation/particle shield protects the nitrogen shields. The pump is subjected to a steady state heat load of less than 10 W due to conduction and radiation heat transfer. The helium tube will be subjected to Joule heating of less than 300 J due to induced current and a particle load of less than 12 W during plasma operation. The thermal design of the cryopump requires that it be cooled by 5 g/s liquid helium at an inlet pressure of 115 kPa and a temperature of 4.35 K. Thermal analysis and tests show that the helium tube can absorb a transient heat load of up to 100 W for 10 s and still pump deuterium at 6.3 K. Disruptions induce toroidal currents in the helium line and nitrogen shields. These currents cross the rapidly changing magnetic fields, applying complex dynamic loads on the cryopump. The forces on the pump are extrapolated from magnetic measurements from DIII-D plasma disruptions and scaled to a 3 MA disruption. The supports for the nitrogen shield consist of a racetrack design, which are stiff for reacting the disruption loads, but are radially flexible to allow differential thermal displacements with the vacuum vessel. Static and dynamic finite element analyses of the cryopump show that the stresses and displacements over a range of disruption and thermal loadings are acceptable

  2. Onset of behavioral effects in mice exposed to 10 Gy Co-60 radiation

    International Nuclear Information System (INIS)

    Maier, D.M.; Landauer, M.R.

    1990-01-01

    The effects of 10 Gray (Gy) Co-60 radiation on social behavior, locomotor activity, and body weight were assessed in individually housed male Swiss-Webster mice. In experiment 1, aggressive behavior was evaluated prior to irradiation and for 7 d postirradiation by placing an untreated intruder in the irradiated or sham-irradiated resident's home cage for 5 min. Offensive aggressive behavior was not affected significantly by radiation until day 7 postirradiation, when attack latency increased, the frequency and duration of fighting decreased, and the frequency of bites, lunges, and chases decreased. Untreated intruder mice paired with irradiated resident mice showed a decrease in the duration of defensive upright postures and a decrease in the frequency of defensive upright postures, squeaks, and escapes on day 7 postirradiation. In experiment 2, locomotor activity and body weight were monitored for 7 d postirradiation. Body weight was decreased in irradiated mice beginning 4 d postirradiation. Locomotor activity was suppressed in irradiated animals 90 min after irradiation and remained depressed throughout the 7-d testing period. 25 refs

  3. Numerical modeling and experimental simulation of vapor shield formation and divertor material erosion for ITER typical plasma disruptions

    International Nuclear Information System (INIS)

    Wuerz, H.; Arkhipov, N.I.; Bakhin, V.P.; Goel, B.; Hoebel, W.; Konkashbaev, I.; Landman, I.; Piazza, G.; Safronov, V.M.; Sherbakov, A.R.; Toporkov, D.A.; Zhitlukhin, A.M.

    1994-01-01

    The high divertor heat load during a tokamak plasma disruption results in sudden evaporation of a thin layer of divertor plate material, which acts as vapor shield and protects the target from further excessive evaporation. Formation and effectiveness of the vapor shield are theoretically modeled and experimentally investigated at the 2MK-200 facility under conditions simulating the thermal quench phase of ITER tokamak plasma disruptions. In the optical wavelength range C II, C III, C IV emission lines for graphite, Cu I, Cu II lines for copper and continuum radiation for tungsten samples are observed in the target plasma. The plasma expands along the magnetic field lines with velocities of (4±1)x10 6 cm/s for graphite and 10 5 cm/s for copper. Modeling was done with a radiation hydrodynamics code in one-dimensional planar geometry. The multifrequency radiation transport is treated in flux limited diffusion and in forward reverse transport approximation. In these first modeling studies the overall shielding efficiency for carbon and tungsten defined as ratio of the incident energy and the vaporization energy for power densities of 10 MW/cm 2 exceeds a factor of 30. The vapor shield is established within 2 μs, the power fraction to the target after 10 μs is below 3% and reaches in the stationary state after about 20 μs a value of around 1.5%. ((orig.))

  4. Ballistic behavior of ultra-high molecular weight polyethylene composite: effect of gamma radiation

    International Nuclear Information System (INIS)

    Alves, Andreia L. dos Santos; Nascimento, Lucio F.C.; Suarez, Joao C. Miguez; lucio2002bol.com.br

    2003-01-01

    Since World War II, textile composites have been used as ballistic armor. Ultra-high molecular weight polyethylene (UHMWPE) fibers are used in the production of armor materials. As they have been developed and commercialized only recently, there is not enough information about the effect of environmental agents in the ballistic performance of UHMWPE composites. In the present work, was evaluated the ballistic behavior of composite plates manufactured with UHMWPE fibers after exposure to gamma radiation. The ballistic tests results were related to the macromolecular alterations induced by the radiation through mechanical (hardness, impact and flexure) and physicochemical (Ftir/Mir. DSC and TGA) testing. It was observed that irradiation induces changes in the UHMWPE, degrading the ballistic performance of the composite. These results are presented and discussed. (author)

  5. Studies of radiation effects on the indicator of behavior and learning of the nematode caenorhabditis elegans

    International Nuclear Information System (INIS)

    Sakashita, Tetsuya; Suzuki, Michiyo

    2011-01-01

    Radiation effects on the essential behavior and its higher level of learning are described mainly on authors' studies of the title nematode (N), a unique model of which, in a whole, genome is mapped, genealogy of cells is defined, and anatomical distribution and linkage of nervous cells are known. N exhibits various behaviors such as meandering on the culture agar/swimming in water responding to given stimuli like touch, temperature, and chemical. Authors have found that the locomotive activity of N is reduced by gamma-irradiation. Their subsequent irradiation study of 60 Co gamma ray at 300-900 Gy (32 Gy/sec) to wild type and cat-2 mutant lacking tyrosine hydroxylase in the presence/absence of N's food has revealed that dopaminergic nerves do not participate in the mechanism of the reduction unexpectedly. Rather, participation of an active oxygen species is suggested by their following study with H 2 O 2 , but exact nervous system responsible to the reduction is still to be elucidated in future. For radiation effect on N's associative learning, authors have used the reversal of salt preference, where Ns cultured on NaCl-containing agar covered by E. coli (food), being chemotactic to the salt, are conditioned by food removal: salt preference is reversed after learning. The gamma ray irradiation at the conditioning stage but neither before nor after learning, is found to lead to reduction of the chemotaxis (promotion of learning), and this radiation response is found to occur in N lacking gpc-1 gene coding G-protein gamma-subunit which is localized in a part of sensory nerves. Authors think this radiation effect is a modulation of nervous circuit for chemotaxis of N, but of which relation with the complicated nervous functions in higher animals is further to be elucidated in aspects of learning and memory. (T.T.)

  6. Mathematical modeling of the radiation-chemical behavior of neptunium in HNO3. Equilibrium states

    International Nuclear Information System (INIS)

    Vladimirova, M.V.

    1995-01-01

    A mathematical model of the radiation-chemical behavior of neptunium is presented for a wide range of α-and γ-irradiation doses. Equations determining the equilibrium concentrations of NP(IV), Np(V), and Np(VI) are derived for various concentrations of HNO 3 and dose rates of the ionizing irradiation. The rate constants of the reactions NP(IV) + OH, Np(IV) + NO 3 , Np(V) + NO 2 , Np(V) + H, Np(IV), and Np(V) + Np(V) are obtained by the mathematical modeling

  7. Study of carbon ion behavior by using collisional radiative model in the GAMMA 10 tandem mirror

    International Nuclear Information System (INIS)

    Kobayashi, Takayuki; Yoshikawa, Masayuki; Kubota, Yuusuke; Saito, Masashi; Matama, Ken; Itakura, Akiyoshi; Cho, Teruji; Kato, Takako

    2006-01-01

    In a plasma experiment, collisional radiative model (CRM) is very useful model to evaluate impurity behaviors and plasma parameters with line emission from a plasma. CRMs for carbon and oxygen have been developed. However verification and application of the model for analysis of experimental results are not enough. Then we applied CRM calculation results to observed impurity spectra in the GAMMA 10 tandem mirror to evaluate the impurity density profile and the particle balance of each charge state of carbon ion. We calculated the effective ionization rate for each charge state of carbon ion and obtained the density profile of each ion. Moreover, we calculated absolute emission intensities from all carbon ions. (author)

  8. Molecular dynamics simulation on the formation and annihilation behaviors of radiation defects in Li2O

    International Nuclear Information System (INIS)

    Takuji Oda; Satoru Tanaka; Yasuhisa Oya

    2006-01-01

    The influence of radiation defects is one of the main factors that determine tritium release behavior from blanket breeding materials in fusion reactors. Classical molecular dynamics simulation (MD) is a powerful technique to investigate the radiation damage processes, because it can provide atomic-scale information on the defects. In this study, we conducted radiation simulation for Li 2 O using MD and analyzed formation and annihilation behaviors of radiation defects, as a fundamental research for radiation response of Li-containing oxides. Buckingham type two-body potential model was used. In order to remove the unphysical impulsive force at short inter-ionic distances in Buckingham model, each potential function was connected to that of the ZBL potential models at around 0.8 A. NEV ensemble was employed with the initial simulation temperature of 0 K. 10 x 10 x 10 supercell consisting of 4000 Li 2 O was used as a unit cell under 3D periodic boundary conditions. Radiation simulation was initiated by introducing an energy of a certain direction to an ion, as a displacement energy. The lowest displacement energy by which a defect was created and survived beyond 5 ps was regarded as the threshold energy. 42 and 21 displacement directions were surveyed for Li and O, respectively, based on the symmetry of the Li 2 O crystal. In both Li and O defect formations, [100] displacement shows significantly lower threshold energy than [111] displacement. Li defects were easily created than O defects almost in all directions. In fact, the average threshold energy except [111] displacement, which possesses extremely high threshold energy, was 21 eV for Li and 49 eV for O. In some cases, no defect could survive beyond 5 ps even by higher displacement energies than the threshold energy, due to the self-annealing effect. The self-annealing completed basically within 1 ps after introduction of displacement energy. At around this time, velocity distribution of all ions in the system

  9. The control of convection by fuelling and pumping in the JET pumped divertor

    Energy Technology Data Exchange (ETDEWEB)

    Harbour, P J; Andrew, P; Campbell, D; Clement, S; Davies, S; Ehrenberg, J; Erents, S K; Gondhalekar, A; Gadeberg, M; Gottardi, N; Von Hellermann, M; Horton, L; Loarte, A; Lowry, C; Maggi, C; McCormick, K; O` Brien, D; Reichle, R; Saibene, G; Simonini, R; Spence, J; Stamp, M; Stork, D; Taroni, A; Vlases, G [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-07-01

    Convection from the scrape-off layer (SOL) to the divertor will control core impurities, if it retains them in a cold, dense, divertor plasma. This implies a high impurity concentration in the divertor, low at its entrance. Particle flux into the divertor entrance can be varied systematically in JET, using the new fuelling and pumping systems. The convection ratio has been estimated for various conditions of operation. Particle convection into the divertor should increase thermal convection, decreasing thermal conduction, and temperature and density gradients along the magnetic field, hence increasing the frictional force and decreasing the thermal force on impurities. Changes in convection in the SOL, caused by gaseous fuelling, have been studied, both experimentally in the JET Mk I divertor and with EDGE2/NIMBUS. 1 ref., 4 figs., 1 tab.

  10. Studies of impurity deposition/implantation in JET divertor tiles using SIMS and ion beam techniques

    International Nuclear Information System (INIS)

    Likonen, J.; Lehto, S.; Coad, J.P.; Renvall, T.; Sajavaara, T.; Ahlgren, T.; Hole, D.E.; Matthews, G.F.; Keinonen, J.

    2003-01-01

    At the end of C4 campaign at JET, a 1% SiH 4 /99% D 2 mixture and pure 13 CH 4 were injected into the torus from the outer divertor wall and from the top of the vessel, respectively, in order to study material transport and scrape-off layer (SOL) flows. A set of MkIIGB tiles was removed during the 2001 shutdown for surface analysis. The tiles were analysed with secondary ion mass spectrometry (SIMS) and time-of-flight elastic recoil detection analysis (TOF-ERDA). 13 C was detected in the inner divertor wall tiles implying material transport from the top of the vessel. Silicon was detected mainly at the outer divertor wall tiles and very small amounts were found in the inner divertor wall tiles. Si amounts in the inner divertor wall tiles were so low that rigorous conclusions about material transport from divertor outboard to inboard cannot be made

  11. Interpretation of low ionized impurity distributions in the ASDEX Upgrade divertor

    International Nuclear Information System (INIS)

    Lieder, G.; Napiontek, B.; Radtke, R.; Field, A.; Fussmann, G.; Kallenbach, A.; Kiemer, K.; Mayer, H.M.

    1993-01-01

    Design studies for reactor-like devices, like ITER, have particularly emphasized the importance of erosion and transport of material from the divertor target plates. In this context experimental measurements which can lead to a better understanding of the underlying physics are highly desirable. We discuss the spatial profiles of line emission from impurities measured in the divertor of ASDEX Upgrade with a recently developed multi-chord divertor spectrometer system. These profiles are obtained from observations in the ultra-violet/visible spectral range. The divertor spectrometer system was developed particularly to measure the erosion of the divertor plates and to study transport of the impurities and the ionization and recombination processes in the divertor region. (author) 6 refs., 3 figs., 2 tabs

  12. Interpretation of low ionized impurity distributions in the ASDEX Upgrade divertor

    Energy Technology Data Exchange (ETDEWEB)

    Lieder, G; Napiontek, B; Radtke, R; Field, A; Fussmann, G; Kallenbach, A; Kiemer, K; Mayer, H M [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany)

    1994-12-31

    Design studies for reactor-like devices, like ITER, have particularly emphasized the importance of erosion and transport of material from the divertor target plates. In this context experimental measurements which can lead to a better understanding of the underlying physics are highly desirable. We discuss the spatial profiles of line emission from impurities measured in the divertor of ASDEX Upgrade with a recently developed multi-chord divertor spectrometer system. These profiles are obtained from observations in the ultra-violet/visible spectral range. The divertor spectrometer system was developed particularly to measure the erosion of the divertor plates and to study transport of the impurities and the ionization and recombination processes in the divertor region. (author) 6 refs., 3 figs., 2 tabs.

  13. Active control of divertor heat and particle fluxes in EAST towards advanced steady state operations

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L., E-mail: lwang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Dalian University of Technology, Dalian 116024 (China); Guo, H.Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); General Atomics, P. O. Box 85608, San Diego, CA 92186 (United States); Li, J.; Wan, B.N.; Gong, X.Z.; Zhang, X.D.; Hu, J.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Liang, Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Association EURATOM-FZJ, D-52425 Jülich (Germany); Xu, G.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); Zou, X.L. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France); Loarte, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); Maingi, R.; Menard, J.E. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Luo, G.N.; Gao, X.; Hu, L.Q.; Gan, K.F.; Liu, S.C.; Wang, H.Q.; Chen, R. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China); and others

    2015-08-15

    Significant progress has been made in EAST towards advanced steady state operations by active control of divertor heat and particle fluxes. Many innovative techniques have been developed to mitigate transient ELM and stationary heat fluxes on the divertor target plates. It has been found that lower hybrid current drive (LHCD) can lead to edge plasma ergodization, striation of the stationary heat flux and lower ELM transient heat and particle fluxes. With multi-pulse supersonic molecular beam injection (SMBI) to quantitatively regulate the divertor particle flux, the divertor power footprint pattern can be actively modified. H-modes have been extended over 30 s in EAST with the divertor peak heat flux and the target temperature being controlled well below 2 MW/m{sup 2} and 250 °C, respectively, by integrating these new methods, coupled with advanced lithium wall conditioning and internal divertor pumping, along with an edge coherent mode to provide continuous particle and power exhaust.

  14. Results of the H-mode experiments with JT-60 outer and lower divertors

    International Nuclear Information System (INIS)

    Nakamura, Hiroo; Tsuji, Shunji; Nagami, Masayuki

    1989-08-01

    In JT-60, hydrogen H-mode experiments with outer and lower divertors were performed. In the outer divertor, H-mode were obtained, similar to the ones observed in the other lower/upper divertors. Its threshold absorbed power and electron density were 16 MW and 1.8 x 10 19 m -3 . In the two combined heatings with NB+ICRF and NB+LHRF, H-mode discharges are also obtained. Moreover, in new configuration of lower divertor, H-mode phases without and with ELM are obtained. Typical results of the lower divertor are shown to compare the H-mode characteristics between the two configurations. Improvement of the energy confinement time in the two divertors was limited to 10 %. Analyses on ballooning/interchange instabilities were carried out with precise equlibria of JT-60. These results showed that the both modes were enough stable. (author)

  15. Engineering, installation, testing, and initial operation of the DIII-D Advanced Divertor

    International Nuclear Information System (INIS)

    Andersen, P.M.; Baxi, C.B.; Reis, E.E.; Schaffer, M.J.; Smith, J.P.

    1990-09-01

    The Advanced Divertor (AD) for General Atomics tokamak, DIII-D, was installed in the summer of 1990. The AD has enabled two classes of physics experiments to be run: divertor biasing and divertor baffling. Both are new experiments for DIII-D. The AD has two principal components: (1) a continuous ring electrode; and (2) a toroidally symmetric baffle. The tokamak can be run in bias baffle or standard DIII-D divertor modes by accurate positioning of the outer divertor strike point through the use of the DIII-D control system. The paper covers design, analysis, fabrication, installation, instrumentation, testing, initial operation, and future plans for the Advanced Divertor from an engineering viewpoint. 2 refs., 5 figs

  16. Divertor heat and particle control experiments on the DIII-D tokamak