WorldWideScience

Sample records for radiant energy outlet

  1. Nonimaging radiant energy device

    Science.gov (United States)

    Winston, Roland; Ning, Xiaohui

    1993-01-01

    A nonimaging radiant energy device may include a hyperbolically shaped reflective element with a radiant energy inlet and a radiant energy outlet. A convex lens is provided at the radiant energy inlet and a concave lens is provided at the radiant energy outlet. Due to the provision of the lenses and the shape of the walls of the reflective element, the radiant energy incident at the radiant energy inlet within a predetermined angle of acceptance is emitted from the radiant energy outlet exclusively within an acute exit angle. In another embodiment, the radiant energy device may include two interconnected hyperbolically shaped reflective elements with a respective convex lens being provided at each aperture of the device.

  2. Design of energy efficient building with radiant slab cooling

    Science.gov (United States)

    Tian, Zhen

    2007-12-01

    Air-conditioning comprises a substantial fraction of commercial building energy use because of compressor-driven refrigeration and fan-driven air circulation. Core regions of large buildings require year-round cooling due to heat gains from people, lights and equipment. Negative environmental impacts include CO2 emissions from electric generation and leakage of ozone-depleting refrigerants. Some argue that radiant cooling simultaneously improves building efficiency and occupant thermal comfort, and that current thermal comfort models fail to reflect occupant experience with radiant thermal control systems. There is little field evidence to test these claims. The University of Calgary's Information and Communications Technology (ICT) Building, is a pioneering radiant slab cooling installation in North America. Thermal comfort and energy performance were evaluated. Measurements included: (1) heating and cooling energy use, (2) electrical energy use for lighting and equipment, and (3) indoor temperatures. Accuracy of a whole building energy simulation model was evaluated with these data. Simulation was then used to compare the radiant slab design with a conventional (variable air volume) system. The radiant system energy performance was found to be poorer mainly due to: (1) simultaneous cooling by the slab and heating by other systems, (2) omission of low-exergy (e.g., groundwater) cooling possible with the high cooling water temperatures possible with radiant slabs and (3) excessive solar gain and conductive heat loss due to the wall and fenestration design. Occupant thermal comfort was evaluated through questionnaires and concurrent measurement of workstation comfort parameters. Analysis of 116 sets of data from 82 occupants showed that occupant assessment was consistent with estimates based on current thermal comfort models. The main thermal comfort improvements were reductions in (1) local discomfort from draft and (2) vertical air temperature stratification. The

  3. Performance of Radiant Heating Systems of Low-Energy Buildings

    Science.gov (United States)

    Sarbu, Ioan; Mirza, Matei; Crasmareanu, Emanuel

    2017-10-01

    After the introduction of plastic piping, the application of water-based radiant heating with pipes embedded in room surfaces (i.e., floors, walls, and ceilings), has significantly increased worldwide. Additionally, interest and growth in radiant heating and cooling systems have increased in recent years because they have been demonstrated to be energy efficient in comparison to all-air distribution systems. This paper briefly describes the heat distribution systems in buildings, focusing on the radiant panels (floor, wall, ceiling, and floor-ceiling). Main objective of this study is the performance investigation of different types of low-temperature heating systems with different methods. Additionally, a comparative analysis of the energy, environmental, and economic performances of floor, wall, ceiling, and floor-ceiling heating using numerical simulation with Transient Systems Simulation (TRNSYS) software is performed. This study showed that the floor-ceiling heating system has the best performance in terms of the lowest energy consumption, operation cost, CO2 emission, and the nominal boiler power. The comparison of the room operative air temperatures and the set-point operative air temperature indicates also that all radiant panel systems provide satisfactory results without significant deviations.

  4. Radiant energy collection and conversion apparatus and method

    Science.gov (United States)

    Hunt, A.J.

    The apparatus for collecting radiant energy and converting to alternate energy forms includes a housing having an interior space and a radiation transparent window allowing solar radiation to be received in the interior space of the housing. Means are provided for passing a stream of fluid past the window and for injecting radiation absorbent particles in said fluid stream. The particles absorb the radiation and because of their very large surface area, quickly release the heat to the surrounding fluid stream. The fluid stream particle mixture is heated until the particles vaporize. The fluid stream is then allowed to expand in, for example, a gas turbine to produce mechanical energy. In an aspect of the present invention properly sized particles need not be vaporized prior to the entrance of the fluid stream into the turbine, as the particles will not damage the turbine blades. In yet another aspect of the invention, conventional fuel injectors are provided to inject fuel into the fluid stream to maintain the proper temperature and pressure of the fluid stream should the source of radiant energy be interrupted. In yet another aspect of the invention, an apparatus is provided which includes means for providing a hot fluid stream having hot particles disbursed therein which can radiate energy, means for providing a cooler fluid stream having cooler particles disbursed therein, which particles can absorb radiant energy and means for passing the hot fluid stream adjacent the cooler fluid stream to warm the cooler fluid and cooler particles by the radiation from the hot fluid and hot particles.

  5. Direct conversion of infrared radiant energy for space power applications

    Science.gov (United States)

    Finke, R. C.

    1982-01-01

    A proposed technology to convert the earth radiant energy (infrared albedo) for spacecraft power is presented. The resultant system would eliminate energy storage requirements and simplify the spacecraft design. The design and performance of a infrared rectenna is discussed.

  6. Integrated application of combined cooling, heating and power poly-generation PV radiant panel system of zero energy buildings

    Science.gov (United States)

    Yin, Baoquan

    2018-02-01

    A new type of combined cooling, heating and power of photovoltaic radiant panel (PV/R) module was proposed, and applied in the zero energy buildings in this paper. The energy system of this building is composed of PV/R module, low temperature difference terminal, energy storage, multi-source heat pump, energy balance control system. Radiant panel is attached on the backside of the PV module for cooling the PV, which is called PV/R module. During the daytime, the PV module was cooled down with the radiant panel, as the temperature coefficient influence, the power efficiency was increased by 8% to 14%, the radiant panel solar heat collecting efficiency was about 45%. Through the nocturnal radiant cooling, the PV/R cooling capacity could be 50 W/m2. For the multifunction energy device, the system shows the versatility during the heating, cooling and power used of building utilization all year round.

  7. ''Super-radiant'' states in intermediate energy nuclear physics

    International Nuclear Information System (INIS)

    Auerbach, N.

    1994-01-01

    A ''super-radiant'' state emerges when, under certain conditions, one or a few ''internal'' states acquire a large collective decay width due to the coupling to one or a few ''external'' decay channels. The rest of the internal states are ''stripped'' of their decay width and become long lived quasistationary states. The essentials of such mechanism and its possible role in intermediate energy nuclear physics are discussed in this work

  8. Influence of increment thickness on radiant energy and microhardness of bulk-fill resin composites.

    Science.gov (United States)

    Karacolak, Gamze; Turkun, L Sebnem; Boyacioglu, Hayal; Ferracane, Jack L

    2018-03-30

    Determining the energy transferred at the bottom of eleven bulk-fill resin composites, comparing top and bottom microhardness's and evaluating the correlation between microhardness and radiant energy were aimed. Samples were placed over the bottom sensor of a visible light transmission spectrophotometer and polymerized for 20 s. The bottom and top Knoop microhardness were measured. Paired t-test and correlation analysis were used for statistics (p≤0.05). In all groups, the bottom radiant energy decreased significantly with increasing thickness. For groups of Aura 2 mm, X-tra Fil 2 and 4 mm, SDR 2 and 4 mm, X-tra Base 2 mm no significant difference was found between top and bottom microhardness. For the bottom levels of Aura, X-tra Fil, Filtek Bulk-Fill Posterior, SDR, X-tra Base groups no significant difference was found between the microhardness's of 2 and 4 mm thicknesses. For X-tra Fil, Tetric Evo Ceram Bulk-Fill, Filtek Bulk-Fill Flowable and Z100 groups radiant energy affected positively the microhardness.

  9. Energy efficiency and indoor thermal perception. A comparative study between radiant panel and portable convective heaters

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Ahmed Hamza H.; Morsy, Mahmoud Gaber [Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Assiut, 71516 (Egypt)

    2010-11-15

    This study investigates experimentally the thermal perception of indoor environment for evaluating the ability of radiant panel heaters to produce thermal comfort for space occupants as well as the energy consumption in comparison with conventional portable natural convective heaters. The thermal perception results show that, compared with conventional convection heater, a radiantly heated office room maintains a lower ambient air temperature while providing equal levels of thermal perception on the thermal dummy head as the convective heater and saves up to 39.1% of the energy consumption per day. However, for human subjects' vote experiments, the results show that for an environmentally controlled test room at outdoor environment temperatures of 0C and 5C, using two radiant panel heaters with a total capacity of 580 W leads to a better comfort sensation than the conventional portable natural convective heater with a 670 W capacity, with an energy saving of about 13.4%. In addition, for an outdoor environment temperature of 10C, using one radiant panel heater with a capacity of 290 W leads to a better comfort sensation than the conventional convection heater with a 670 W capacity, with an energy saving of about 56.7%. From the analytical results, it is found that distributing the radiant panel heater inside the office room, one on the wall facing the window and the other on the wall close to the window, provides the best operative temperature distribution within the room.

  10. Energy flow and thermal comfort in buildings: Comparison of radiant and air-based heating & cooling systems

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme

    is based on both radiation and convection. This thesis focuses on characterizing the heat transfer from the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam...... losses, and an air-based terminal might be more energy-efficient than a radiant terminal (in terms of delivered energy). Regarding comfort, a similar global level has been observed for the radiant and air-based terminals in both numerical and experimental investigations. But the different terminals did...... not achieve the same uniformity in space. The active chilled beam theoretically achieves the most uniform comfort conditions (when disregarding the risk of draught), followed by the radiant ceiling. The least uniform conditions were obtained with the cooled floor due to large differences between the sitting...

  11. Energy flow and thermal comfort in buildings: Comparison of radiant and air-based heating & cooling systems

    DEFF Research Database (Denmark)

    Le Dréau, Jérôme

    Heating and cooling terminals can be classified in two main categories: convective terminals (e.g air conditioning, active chilled beam, fan coil) and radiant terminals. The two terminals have different modes of heat transfer: the first one is mainly based on convection, whereas the second one...... is based on both radiation and convection. This thesis focuses on characterizing the heat transfer from the terminal towards the space and on the parameters influencing the effectiveness of terminals. Therefore the comfort conditions and energy consumption of four types of terminals (active chilled beam...... losses, and an air-based terminal might be more energy-efficient than a radiant terminal (in terms of delivered energy). Regarding comfort, a similar global level has been observed for the radiant and air-based terminals in both numerical and experimental investigations. But the different terminals did...

  12. Numerical Simulation of the Thermal Process in a W-Shape Radiant Tube Burner

    Science.gov (United States)

    Wang, Yi; Li, Jiyong; Zhang, Lifeng; Ling, Haitao; Li, Yanlong

    2014-07-01

    In the current work, three-dimensional mathematical models were developed for the heat transfer and combustion in a W-shape radiant tube burner (RTB) and were solved using Fluent software (ANSYS Inc., Canonsburg, PA). The standard k- ɛ model, nonpremixed combustion model, and the discrete ordinate model were used for the modeling of turbulence, combustion, and radiant heat transfer, respectively. In addition, the NO x postprocessor was used for the prediction of the NO emission. A corresponding experiment was performed for the validation of mathematical models. The details of fluid flow, heat transfer, and combustion in the RTB were investigated. Moreover, the effect of the air/fuel ratio (A/F) and air staging on the performance of RTB was studied with the reference indexes including heat efficiency, maximum temperature difference on shell wall, and NO emission at the outlet. The results indicated that a low speed zone formed in the vicinity of the combustion chamber outlet, and there were two relative high-temperature zones in the RTB, one in combustion chamber that favored the flame stability and the other from the main flame in the RTB. The maximum temperature difference was 95.48 K. As the A/F increased, the temperature increased first and then decreased. As the ratio of the primary to secondary air increased, the recirculation zone at the outlet of combustion chamber shrank gradually to disappear, and the flame length was longer and the temperature in flame decreased correspondingly.

  13. Performance evaluation of radiant cooling system application on a university building in Indonesia

    Science.gov (United States)

    Satrio, Pujo; Sholahudin, S.; Nasruddin

    2017-03-01

    The paper describes a study developed to estimate the energy savings potential of a radiant cooling system installed in an institutional building in Indonesia. The simulations were carried out using IESVE to evaluate thermal performance and energy consumption The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption and temperature distribution to determine the proportional energy savings and occupant comfort under different systems. The result was radiant cooling which integrated with a Dedicated Outside Air System (DOAS) could make 41,84% energy savings compared to the installed cooling system. The Computational Fluid Dynamics (CFD) simulation showed that a radiant system integrated with DOAS provides superior human comfort than a radiant system integrated with Variable Air Volume (VAV). Percentage People Dissatisfied was kept below 10% using the proposed system.

  14. Performance analysis on solar-water compound source heat pump for radiant floor heating system

    Institute of Scientific and Technical Information of China (English)

    曲世林; 马飞; 仇安兵

    2009-01-01

    A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.

  15. Exergy metrication of radiant panel heating and cooling with heat pumps

    International Nuclear Information System (INIS)

    Kilkis, Birol

    2012-01-01

    Highlights: ► Rational Exergy Management Model analytically relates heat pumps and radiant panels. ► Heat pumps driven by wind energy perform better with radiantpanels. ► Better CO 2 mitigation is possible with wind turbine, heat pump, radiant panel combination. ► Energy savings and thermo-mechanical performance are directly linked to CO 2 emissions. - Abstract: Radiant panels are known to be energy efficient sensible heating and cooling systems and a suitable fit for low-exergy buildings. This paper points out the little known fact that this may not necessarily be true unless their low-exergy demand is matched with low-exergy waste and alternative energy resources. In order to further investigate and metricate this condition and shed more light on this issue for different types of energy resources and energy conversion systems coupled to radiant panels, a new engineering metric was developed. Using this metric, which is based on the Rational Exergy Management Model, true potential and benefits of radiant panels coupled to ground-source heat pumps were analyzed. Results provide a new perspective in identifying the actual benefits of heat pump technology in curbing CO 2 emissions and also refer to IEA Annex 49 findings for low-exergy buildings. Case studies regarding different scenarios are compared with a base case, which comprises a radiant panel system connected to a natural gas-fired condensing boiler in heating and a grid power-driven chiller in cooling. Results show that there is a substantial CO 2 emission reduction potential if radiant panels are optimally operated with ground-source heat pumps driven by renewable energy sources, or optimally matched with combined heat and power systems, preferably running on alternative fuels.

  16. Radiant Barriers Save Energy in Buildings

    Science.gov (United States)

    2014-01-01

    Langley Research Center needed to coat the Echo 1 satellite with a fine mist of vaporized metal, and collaborated with industry to create "radiant barrier technology." In 2010, Ryan Garrett learned about a new version of the technology resistant to oxidation and founded RadiaSource in Ogden, Utah, to provide the NASA-derived technology for applications in homes, warehouses, gymnasiums, and agricultural settings.

  17. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  18. Radiant energy during infrared neural stimulation at the target structure

    Science.gov (United States)

    Richter, Claus-Peter; Rajguru, Suhrud; Stafford, Ryan; Stock, Stuart R.

    2013-03-01

    Infrared neural stimulation (INS) describes a method, by which an infrared laser is used to stimulate neurons. The major benefit of INS over stimulating neurons with electrical current is its spatial selectivity. To translate the technique into a clinical application it is important to know the energy required to stimulate the neural structure. With this study we provide measurements of the radiant exposure, at the target structure that is required to stimulate the auditory neurons. Flat polished fibers were inserted into scala tympani so that the spiral ganglion was in front of the optical fiber. Angle polished fibers were inserted along scala tympani, and rotating the beveled surface of the fiber allowed the radiation beam to be directed perpendicular to the spiral ganglion. The radiant exposure for stimulation at the modiolus for flat and angle polished fibers averaged 6.78+/-2.15 mJ/cm2. With the angle polished fibers, a 90º change in the orientation of the optical beam from an orientation that resulted in an INS-evoked maximum response, resulted in a 50% drop in the response amplitude. When the orientation of the beam was changed by 180º, such that it was directed opposite to the orientation with the maxima, minimum response amplitude was observed.

  19. Thermal model of attic systems with radiant barriers

    Energy Technology Data Exchange (ETDEWEB)

    Wilkes, K.E.

    1991-07-01

    This report summarizes the first phase of a project to model the thermal performance of radiant barriers. The objective of this phase of the project was to develop a refined model for the thermal performance of residential house attics, with and without radiant barriers, and to verify the model by comparing its predictions against selected existing experimental thermal performance data. Models for the thermal performance of attics with and without radiant barriers have been developed and implemented on an IBM PC/AT computer. The validity of the models has been tested by comparing their predictions with ceiling heat fluxes measured in a number of laboratory and field experiments on attics with and without radiant barriers. Cumulative heat flows predicted by the models were usually within about 5 to 10 percent of measured values. In future phases of the project, the models for attic/radiant barrier performance will be coupled with a whole-house model and further comparisons with experimental data will be made. Following this, the models will be utilized to provide an initial assessment of the energy savings potential of radiant barriers in various configurations and under various climatic conditions. 38 refs., 14 figs., 22 tabs.

  20. Radiant floor cooling coupled with dehumidification systems in residential buildings: A simulation-based analysis

    International Nuclear Information System (INIS)

    Zarrella, Angelo; De Carli, Michele; Peretti, Clara

    2014-01-01

    Highlights: • The floor radiant cooling in a typical apartment is analyzed. • Dehumidification devices, fan-coil and mechanical ventilation are compared. • The results are analyzed in terms of both thermal comfort and energy consumption. • The energy consumption of the dehumidifiers is higher than that of other systems. • The mechanical ventilation decreases the moisture level better than other systems. - Abstract: The development of radiant cooling has stimulated an interest in new systems based on coupling ventilation with radiant cooling. However, radiant cooling systems may cause condensation to form on an active surface under warm and humid conditions during the cooling season. This phenomenon occurs when surface temperature falls below dew point. To prevent condensation, air humidity needs to be reduced with a dehumidification device or a mechanical ventilation system. There are two main options to achieve this. The first is to use dehumidification devices that reduce humidity, but are not coupled with ventilation, i.e. devices that handle room air and leave air change to infiltrations. The second is to combine a mechanical ventilation system with dehumidifying finned coils. This study analyzes the floor radiant cooling of a typical residential apartment within a multi-storey building in three Italian climate zones by means of a detailed simulation tool. Five systems were compared in terms of both indoor thermal comfort and energy consumption: radiant cooling without dehumidification; radiant cooling with a soft dehumidification device; radiant cooling with a dehumidification device which also supplies sensible cooling; radiant cooling coupled with fan coils; and radiant cooling with a mechanical ventilation system which dehumidifies and cools

  1. Radiant cooling of an enclosure

    International Nuclear Information System (INIS)

    Chebihi, Abdeslam; Byun, Ki-Hong; Wen Jin; Smith, Theodore F.

    2006-01-01

    The purpose of this study is to analyze the potential for radiant cooling using the atmospheric sky window and to evaluate the desired characteristics of a radiant cooling material (RCM) applied to the ceiling window of a three-dimensional enclosure. The thermal characteristics of the system are governed by the geometry, ambient temperature, sky radiative temperature, amount of solar energy and its direction, heat transfer modes, wall radiative properties, and radiative properties of the RCMs. A semi-gray band analysis is utilized for the solar and infrared bands. The radiosity/irradiation method is used in each band to evaluate the radiant exchanges in the enclosure. The radiative properties for the RCM are varied in a parametric study to identify the desired properties of RCMs. For performance simulation of real RCMs, the radiative properties are calculated from spectral data. The desired solar property is a high reflectance for both opaque and semi-transparent RCMs. For a semi-transparent RCM, a low value of the solar transmittance is preferred. The desired infrared property is a high emittance for an opaque RCM. For a semi-transparent RCM, a high infrared transmittance is desired, and the emittance should be greater than zero

  2. Effects of Floor Covering Resistance of a Radiant Floor on System Energy and Exergy Performances

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Shukuya, Masanori; Olesen, Bjarne W.

    2016-01-01

    Floor covering resistance (material and thickness) can be influenced by subjective choices (architectural design, interior design, texture, etc.) with significant effects on the performance of a radiant heating and cooling system. To study the effects of floor covering resistance on system...... performance, a water-based radiant floor heating and cooling system (dry, wooden construction) was considered to be coupled to an air-to-water heat pump, and the effects of varying floor covering resistances (0.05 m2K/W, 0.09 m2K/W and 0.15 m2K/W) on system performance were analyzed in terms of energy...... and exergy. In order to achieve the same heating and cooling outputs, higher average water temperatures are required in the heating mode (and lower temperatures in the cooling mode) with increasing floor covering resistance. These temperature requirements decrease the heat pump’s performance (lower...

  3. Solar–terrestrial radiant-energy regimes and temperature anomalies of natural and artificial turfs

    International Nuclear Information System (INIS)

    Jim, C.Y.

    2016-01-01

    Highlights: • Solar and terrestrial radian energy regimes affect temperature response of sports turfs. • Adjacent natural and artificial turfs were monitored with replications on sunny days. • Artificial turf has meager albedo, low specific heat and moisture to augment warming. • Artificial turf surface and substrate reach 70 °C but cool down effectively at night. • Artificial turf may induce heat stress on athletes in hot summer afternoon. - Abstract: Artificial turf can develop unusually high surface temperature on hot sunny days. Solar and terrestrial radiant energy regimes as key determinants of thermal performance deserve detailed investigation. This study evaluated six components of the radiant-energy environment of a natural turf (NT) and a contiguous artificial turf (AT) sports fields in Hong Kong: direct solar, reflected solar, net solar, sky thermal, ground thermal, and net thermal. Temperature was monitored at five positions: air at 150 cm, 50 cm and 15 cm height, turf surface, and substrate. The experiment included four replications, namely two summer sunny days, and two duplicated instrument sets at each turf site. The two sites reacted very differently to the same intense daily sum of solar radiation input of 23.70 MW m −2 with 9 h of bright sunshine (>120 W m −2 ), and daily sum of sky thermal radiation input of 38.59 MW m −2 . The maximum direct solar radiation reached 976.1 W m −2 at 1245 h. NT albedo of 0.23 vis-à-vis AT of merely 0.073, and higher moisture content and specific heat of NT materials, presented critical differences. The hydrophobic and generally dry plastic (polyethylene) pile-fibers and black rubber-granule infill materials have low specific heat. Intense incoming shortwave and longwave radiation absorbed readily by AT materials raised turf surface temperature to 70.2 °C and substrate 69.3 °C, in comparison with <40 °C at NT. A cascading warming effect was triggered, beginning with low albedo, high net solar

  4. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation and radiant heating/cooling systems. Two test setups simulated a room in a low energy building with a single occupant during winter. The room was equipped either by a ventilation system...... supplying warm air space heating or by a combination of radiant floor heating and mixing ventilation system. Next two test setups simulated an office room with two occupants during summer, ventilated and cooled by a single displacement ventilation system or by a radiant floor cooling combined...

  5. Radiant heating of petroleum reservoirs; Aquecimento radiante de reservatorios petroliferos

    Energy Technology Data Exchange (ETDEWEB)

    Sidrim, Fernando A.C.

    1990-12-31

    This work presents a proposal of a simplified model for the enhanced oil recovery process through radiant heating of oil reservoirs. The resulting continuity, energy and motion equations were solved analytically for the prediction of the increase in well flow rates. The heat loss to adjacent formations and the necessary for the establishment of the temperature profile,which are transient terms of energy equation, have been neglected. Also, no temperature gradient in the axial direction has been modelled as a cylindrical wave propagating in a loss medium. It is concluded that: the inclusion of a radial conduction term in the energy equation led to higher flow rates than the ones predicted by the literature existing solution; if the absorption coefficient is too large, it is profitable to dry the reservoir around the well bore; the transient terms in the energy equation are significant for extended periods of well production. 47 refs., 18 figs., 4 tabs.

  6. Experimental evaluation of an active solar thermoelectric radiant wall system

    International Nuclear Information System (INIS)

    Liu, ZhongBing; Zhang, Ling; Gong, GuangCai; Han, TianHe

    2015-01-01

    Highlights: • A novel active solar thermoelectric radiant wall are proposed and tested. • The novel wall can control thermal flux of building envelope by using solar energy. • The novel wall can eliminate building envelop thermal loads and provide cooling capacity for space cooling. • Typical application issues including connection strategies, coupling with PV system etc. are discussed. - Abstract: Active solar thermoelectric radiant wall (ASTRW) system is a new solar wall technology which integrates thermoelectric radiant cooling and photovoltaic (PV) technologies. In ASTRW system, a PV system transfers solar energy directly into electrical energy to power thermoelectric cooling modes. Both the thermoelectric cooling modes and PV system are integrated into one enclosure surface as radiant panel for space cooling and heating. Hence, ASTRW system presents fundamental shift from minimizing building envelope energy losses by optimizing the insulation thickness to a new regime where active solar envelop is designed to eliminate thermal loads and increase the building’s solar gains while providing occupant comfort in all seasons. This article presents an experimental study of an ASTRW system with a dimension of 1580 × 810 mm. Experimental results showed that the inner surface temperature of the ASTRW is 3–8 °C lower than the indoor temperature of the test room, which indicated that the ASTRW system has the ability to control thermal flux of building envelope by using solar energy and reduce the air conditioning system requirements. Based on the optimal operating current of TE modules and the analysis based upon PV modeling theories, the number and type of the electrical connections for the TE modules in ASTRW system are discussed in order to get an excellent performance in the operation of the ASTRW system

  7. The Influence of a Radiant Panel System with Integrated Phase Change Material on Energy Use and Thermal Indoor Environment

    DEFF Research Database (Denmark)

    Nielsen, Lin Flemming; Bourdakis, Eleftherios; Kazanci, Ongun Berk

    2018-01-01

    This study examined the effect on energy use and thermal comfort when combining microencapsulated phase change material (PCM) with radiant ceiling panels in a two-person office. The performance of the system was studied during the cooling season in the climates of Copenhagen, Denmark, and Rome...

  8. Experimental and Numerical Study of the Radiant Induction-Unit and the Induction Radiant Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Qiang Si

    2016-12-01

    Full Text Available In this paper we proposed the novel air-conditioning system which combined induction ventilation and radiant air-conditioning. The indoor terminal device is the radiant induction-unit (RIDU. The RIDU is the induction unit combined with the pore radiant panel on which the copper pipes with rigid aluminum diffusion fins are installed. The two-stage evaporator chiller with the non-azeotropic mixture refrigerant is utilized in the system to reduce the initial investment in equipment. With the performance test and the steady state heat transfer model based on the theory of radiative heat transfer, the relationship between the induction ratio of the RIDU and the characteristic of the air supply was studied. Based on this, it is verified that the RIDU has a lower dew-point temperature and better anti-condensation performance than a traditional plate-type radiant panel. The characteristics of the radiation and convection heat transfer of the RIDU were studied. The total heat exchange of the RIDU can be 16.5% greater than that of the traditional plate-type radiant terminal.

  9. Radiant exchange in partially specular architectural environments

    Science.gov (United States)

    Beamer, C. Walter; Muehleisen, Ralph T.

    2003-10-01

    The radiant exchange method, also known as radiosity, was originally developed for thermal radiative heat transfer applications. Later it was used to model architectural lighting systems, and more recently it has been extended to model acoustic systems. While there are subtle differences in these applications, the basic method is based on solving a system of energy balance equations, and it is best applied to spaces with mainly diffuse reflecting surfaces. The obvious drawback to this method is that it is based around the assumption that all surfaces in the system are diffuse reflectors. Because almost all architectural systems have at least some partially specular reflecting surfaces in the system it is important to extend the radiant exchange method to deal with this type of surface reflection. [Work supported by NSF.

  10. Radiant Heating and Cooling Systems. Part one

    DEFF Research Database (Denmark)

    Kim, Kwan Woo; Olesen, Bjarne W.

    2015-01-01

    The use of radiant heating systems has several thousand years of history.1,2 The early stage of radiant system application was for heating purposes, where hot air from flue gas (cooking, fires) was circulated under floors or in walls. After the introduction of plastic piping water-based radiant...

  11. Validation of the uncertainty budget for soft X-ray radiant power measurement using a cryogenic radiometer

    CERN Document Server

    Rabus, H; Scholze, F; Thornagel, R; Ulm, G

    2002-01-01

    The cryogenic radiometer SYRES, a thermal detector based on the electrical substitution principle, has been used as the primary detector standard for radiant power measurement in the ultraviolet, vacuum ultraviolet and soft X-ray spectral ranges. In order to investigate the possibility of radiant energy being deposited in its absorber cavity without being transformed into heat when detecting soft X-rays, SYRES has been directly compared with the electron storage ring BESSY 1, a primary radiometric source standard of calculable spectral radiant power. To this end, the integral radiant power emitted by the storage ring,into a solid angle defined by a high-precision aperture was measured with SYRES. The experiments were conducted at two nominal energies of the circulating electrons, 800 MeV and 340 MeV, to study the influence of the different spectral distributions of the synchrotron radiation. For the original graphite-coated cavity absorber, significant discrepancies were found which could be traced back to th...

  12. Extinction of radiant energy by large atmospheric crystals with different shapes

    International Nuclear Information System (INIS)

    Shefer, Olga

    2016-01-01

    The calculated results of extinction characteristics of visible and infrared radiation for large semi-transparent crystals are obtained by hybrid technique, which is a combination of the geometric optics method and the physical optics method. Energy and polarization characteristics of the radiation extinction in terms of the elements of the extinction matrix for individual large crystals and ensemble of crystals are discussed. Influences of particle shapes, aspect ratios, parameters of size distribution, complex refractive index, orientation of crystals, wavelength, and the polarization state of an incident radiation on the extinction are illustrated. It is shown that the most expressive and stable features of energy and polarization characteristics of the extinction are observed in the midinfrared region, despite the fact that the ice particles significantly absorb the radiant energy of this spectrum. It is demonstrated that the polarized extinction characteristics can reach several tens of percent at IR wavelengths. For the large crystals, the conditions of occurrence of the spectral behavior of the extinction coefficient in the visible, near-IR, and mid-IR wavelength ranges are determined. - Highlights: • Method of physical optics is used at coherent sum of diffracted and refracted fields. • The extinction characteristics in terms of elements of extinction matrix are obtained. • Influence of shapes and sizes of large particles on the extinction is evaluated. • Conditions of occurrence of extinction features are determined.

  13. Mean energy of ions at outlet of a type Ecr plasma source

    International Nuclear Information System (INIS)

    Gutierrez T, C.; Gonzalez D, J.

    1998-01-01

    In this work it is described the calculations to mean energy of the ions in the extraction zone of a type Ecr plasma source considering the presence of a metallic substrate. This zone is characterized by the existence of a divergent magnetic field. It is showed that mean energy is function as the distance between the outlet and substrate as the value of the external magnetic field. (Author)

  14. Validation of the uncertainty budget for soft X-ray radiant power measurement using a cryogenic radiometer

    International Nuclear Information System (INIS)

    Rabus, H.; Klein, R.; Scholze, F.; Thornagel, R.; Ulm, G.

    2002-01-01

    The cryogenic radiometer SYRES, a thermal detector based on the electrical substitution principle, has been used as the primary detector standard for radiant power measurement in the ultraviolet, vacuum ultraviolet and soft X-ray spectral ranges. In order to investigate the possibility of radiant energy being deposited in its absorber cavity without being transformed into heat when detecting soft X-rays, SYRES has been directly compared with the electron storage ring BESSY 1, a primary radiometric source standard of calculable spectral radiant power. To this end, the integral radiant power emitted by the storage ring,into a solid angle defined by a high-precision aperture was measured with SYRES. The experiments were conducted at two nominal energies of the circulating electrons, 800 MeV and 340 MeV, to study the influence of the different spectral distributions of the synchrotron radiation. For the original graphite-coated cavity absorber, significant discrepancies were found which could be traced back to the ablation of the graphite coating from the copper cavity body. In the case of the new gold-coated cavity absorber, the calculated and measured values of the radiant power agreed in all experiments within the combined relative uncertainties of typically 2.5 x 10 -3 (k = 1). (author)

  15. Radiant absorption characteristics of corrugated curved tubes

    Directory of Open Access Journals (Sweden)

    Đorđević Milan Lj.

    2017-01-01

    Full Text Available The utilization of modern paraboloidal concentrators for conversion of solar radiation into heat energy requires the development and implementation of compact and efficient heat absorbers. Accurate estimation of geometry influence on absorption characteristics of receiver tubes is an important step in this process. This paper deals with absorption characteristics of heat absorber made of spirally coiled tubes with transverse circular corrugations. Detailed 3-D surface-to-surface Hemicube method was applied to compare radiation performances of corrugated and smooth curved tubes. The numerical results were obtained by varying the tube curvature ratio and incident radiant heat flux intensity. The details of absorption efficiency of corrugated tubes and the effect of curvature on absorption properties for both corrugated and smooth tubes were presented. The results may have significance to further analysis of highly efficient heat absorbers exposed to concentrated radiant heating. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 42006

  16. Clouds and the Earth's Radiant Energy System (CERES) Data Products for Climate Research

    Science.gov (United States)

    Kato, Seiji; Loeb, Norman G.; Rutan, David A.; Rose, Fred G.

    2015-01-01

    NASA's Clouds and the Earth's Radiant Energy System (CERES) project integrates CERES, Moderate Resolution Imaging Spectroradiometer (MODIS), and geostationary satellite observations to provide top-of-atmosphere (TOA) irradiances derived from broadband radiance observations by CERES instruments. It also uses snow cover and sea ice extent retrieved from microwave instruments as well as thermodynamic variables from reanalysis. In addition, these variables are used for surface and atmospheric irradiance computations. The CERES project provides TOA, surface, and atmospheric irradiances in various spatial and temporal resolutions. These data sets are for climate research and evaluation of climate models. Long-term observations are required to understand how the Earth system responds to radiative forcing. A simple model is used to estimate the time to detect trends in TOA reflected shortwave and emitted longwave irradiances.

  17. Advanced radiant combustion system. Final report, September 1989--September 1996

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, J.D.; Carswell, M.G.; Long, F.S.

    1996-09-01

    Results of the Advanced Radiant Combustion System (ARCS) project are presented in this report. This work was performed by Alzeta Corporation as prime contractor under a contract to the U.S. Department of Energy Office of Industrial Technologies as part of a larger DOE program entitled Research Program for Advanced Combustion Systems. The goals of the Alzeta ARCS project were to (a) Improve the high temperature performance characteristics of porous surface ceramic fiber burners, (b) Develop an Advanced Radiant Combustion System (ARCS) that combines combustion controls with an advanced radiant burner, and (c) Demonstrate the advanced burner and controls in an industrial application. Prior to the start of this project, Alzeta had developed and commercialized a porous surface radiant burner, the Pyrocore{trademark} burner. The product had been commercially available for approximately 5 years and had achieved commercial success in a number of applications ranging from small burners for commercial cooking equipment to large burners for low temperature industrial fluid heating applications. The burner was not recommended for use in applications with process temperatures above 1000{degrees}F, which prevented the burner from being used in intermediate to high temperature processes in the chemical and petroleum refining industries. The interest in increasing the maximum use temperature of the burner was motivated in part by a desire to expand the number of applications that could use the Pyrocore product, but also because many of the fluid sensitive heating applications of interest would benefit from the distributed flux characteristic of porous surface burners. Background information on porous surface radiant burners, and a discussion of advantages that would be provided by an improved product, are presented in Section 2.

  18. Numerical Modeling of Conjugate Thermogravitational Convection in a Closed System with a Radiant Energy Source in Conditions of Convective-Radiative Heat Exchange at the External Boundary

    Directory of Open Access Journals (Sweden)

    Nee Alexander

    2016-01-01

    Full Text Available Mathematical modeling of conjugate natural convection in a closed rectangular cavity with a radiant energy source in conditions of convective-radiative heat exchange at the external boundary was conducted. The radiant energy distribution was set by the Lambert’s law. Conduction and convection processes analysis showed that the air masses flow pattern is modified slightly over the time. The temperature increases in the gas cavity, despite the heat removal from the one of the external boundary. According to the results of the integral heat transfer analysis were established that the average Nusselt number (Nuav increasing occurs up to τ = 200 (dimensionless time. Further Nuav has changed insignificantly due to the temperature field equalization near the interfaces “gas – wall”.

  19. Airflow and Heat Transfer in the Slot-Vented Room with Radiant Floor Heating Unit

    Directory of Open Access Journals (Sweden)

    Xiang-Long Liu

    2012-01-01

    Full Text Available Radiant floor heating has received increasing attention due to its diverse advantages, especially the energy saving as compared to the conventional dwelling heating system. This paper presents a numerical investigation of airflow and heat transfer in the slot-vented room with the radiant floor heating unit. Combination of fluid convection and thermal radiation has been implemented through the thermal boundary conditions. Spatial distributions of indoor air temperature and velocity, as well as the heat transfer rates along the radiant floor and the outer wall, have been presented and analyzed covering the domains from complete natural convection to forced convection dominated flows. The numerical results demonstrate that the levels of average temperature in the room with lateral slot-ventilation are higher than those without slot-ventilation, but lower than those in the room with ceiling slot-ventilation. Overall, the slot-ventilation room with radiant floor heating unit could offer better indoor air quality through increasing the indoor air temperature and fresh air exchanging rate simultaneously. Concerning the airborne pollutant transports and moisture condensations, the performance of radiant floor heating unit will be further optimized in our future researches.

  20. Energy to the Edge (E2E) Equipment Assessment U.S. Army Rapid Equipping Force

    Science.gov (United States)

    2015-05-01

    84 Contents Energy to the Edge • U.S. Army Rapid Equipping Force U.S. Army Rapid Equipping Force 1.0 Executive Summary Executive Summary U.S. Army... audiovisual equipment. • Once radiant barrier liner is inserted, the process of subsequent setups • Cables for lighting and outlets are located...behind the internal barrier • The shelter comes with organic audiovisual equipment. b. • • This shelter has a different setup and tear down process

  1. Surface radiant flux densities inferred from LAC and GAC AVHRR data

    Science.gov (United States)

    Berger, F.; Klaes, D.

    To infer surface radiant flux densities from current (NOAA-AVHRR, ERS-1/2 ATSR) and future meteorological (Envisat AATSR, MSG, METOP) satellite data, the complex, modular analysis scheme SESAT (Strahlungs- und Energieflüsse aus Satellitendaten) could be developed (Berger, 2001). This scheme allows the determination of cloud types, optical and microphysical cloud properties as well as surface and TOA radiant flux densities. After testing of SESAT in Central Europe and the Baltic Sea catchment (more than 400scenes U including a detailed validation with various surface measurements) it could be applied to a large number of NOAA-16 AVHRR overpasses covering the globe.For the analysis, two different spatial resolutions U local area coverage (LAC) andwere considered. Therefore, all inferred results, like global area coverage (GAC) U cloud cover, cloud properties and radiant properties, could be intercompared. Specific emphasis could be made to the surface radiant flux densities (all radiative balance compoments), where results for different regions, like Southern America, Southern Africa, Northern America, Europe, and Indonesia, will be presented. Applying SESAT, energy flux densities, like latent and sensible heat flux densities could also be determined additionally. A statistical analysis of all results including a detailed discussion for the two spatial resolutions will close this study.

  2. Simplified Building Thermal Model Used for Optimal Control of Radiant Cooling System

    Directory of Open Access Journals (Sweden)

    Lei He

    2016-01-01

    Full Text Available MPC has the ability to optimize the system operation parameters for energy conservation. Recently, it has been used in HVAC systems for saving energy, but there are very few applications in radiant cooling systems. To implement MPC in buildings with radiant terminals, the predictions of cooling load and thermal environment are indispensable. In this paper, a simplified thermal model is proposed for predicting cooling load and thermal environment in buildings with radiant floor. In this thermal model, the black-box model is introduced to derive the incident solar radiation, while the genetic algorithm is utilized to identify the parameters of the thermal model. In order to further validate this simplified thermal model, simulated results from TRNSYS are compared with those from this model and the deviation is evaluated based on coefficient of variation of root mean square (CV. The results show that the simplified model can predict the operative temperature with a CV lower than 1% and predict cooling loads with a CV lower than 10%. For the purpose of supervisory control in HVAC systems, this simplified RC thermal model has an acceptable accuracy and can be used for further MPC in buildings with radiation terminals.

  3. Ten questions about radiant heating and cooling systems

    DEFF Research Database (Denmark)

    Rhee, Kyu-Nam; Olesen, Bjarne W.; Kim, Kwang Woo

    2017-01-01

    studies on RHC systems in terms of comfort, heat transfer analysis, energy simulation, control strategy, system configurations and so on. Many studies have demonstrated that the RHC system is a good solution to improve indoor environmental quality while reducing building energy consumption for heating......Radiant heating and cooling (RHC) systems are being increasingly applied not only in residential but also in non-residential buildings such as commercial buildings, education facilities, and even large scale buildings such as airport terminals. Furthermore, with the combined ventilation system used...

  4. Radiant Heat Transfer in Reusable Surface Insulation

    Science.gov (United States)

    Hughes, T. A.; Linford, R. M. F.; Chmitt, R. J.; Christensen, H. E.

    1973-01-01

    During radiant testing of mullite panels, temperatures in the insulation and support structure exceeded those predicted on the basis of guarded hot plate thermal conductivity tests. Similar results were obtained during arc tunnel tests of mullite specimens. The differences between effective conductivity and guarded hot plate values suggested that radiant transfer through the mullite was occurring. To study the radiant transport, measurements were made of the infrared transmission through various insulating materials and fibers of interest to the shuttle program, using black body sources over the range of 780 to 2000 K. Experimental data were analyzed and scattering coefficients were derived for a variety of materials, fiber diameters, and source temperature.

  5. Use of local convective and radiant cooling at warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2012-01-01

    The effect of four local cooling devices (convective, radiant and combined) on SBS symptoms reported by 24 subjects at 28 ˚C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels and (4) two radiant panels...... and with radiant panel with attached fans, which also helped people to feel less fatigue. The SBS symptoms increased the most when the cooling fan, generating movement of polluted room air, was used....

  6. Radiant heat testing of the H1224A shipping/storage container

    Energy Technology Data Exchange (ETDEWEB)

    Harding, D.C.; Bobbe, J.G.; Stenberg, D.R.; Arviso, M.

    1994-05-01

    H1224A weapons containers have been used for years by the Departments of Energy and Defense to transport and store W78 warhead midsections. Although designed to protect the midsections only from low-energy impacts, a recent transportation risk assessment effort has identified a need to evaluate the container`s ability to protect weapons in more severe accident environments. Four radiant heat tests were performed: two each on an H1224A container (with a Mk12a Mod 6c mass mock-up midsection inside) and two on a low-cost simulated H1224A container (with a hollow Mk12 aeroshell midsections inside). For each unit tested, temperatures were recorded at numerous points throughout the container and midsection during a 4-hour 121{degrees}C (250{degrees}F) and 30-minute 1010{degrees}C (1850{degrees}F) radiant environment. Measured peak temperatures experienced by the inner walls of the midsections as a result of exposure to the high-temperature radiant environment ranged from 650{degrees} C to 980{degrees} C (1200{degrees} F to 1800{degrees}F) for the H1224A container and 770 {degrees} to 990 {degrees}C (1420{degrees} F to 1810{degrees}F) for the simulated container. The majority of both containers were completely destroyed during the high-temperature test. Temperature profiles will be used to benchmark analytical models and predict warhead midsection temperatures over a wide range of the thermal accident conditions.

  7. Numerical Model and Experimental Analysis of the Thermal Behavior of Electric Radiant Heating Panels

    Directory of Open Access Journals (Sweden)

    Giovanni Ferrarini

    2018-01-01

    Full Text Available Electric radiant heating panels are frequently selected during the design phase of residential and industrial heating systems, especially for retrofit of existing buildings, as an alternative to other common heating systems, such as radiators or air conditioners. The possibility of saving living and working space and the ease of installation are the main advantages of electric radiant solutions. This paper investigates the thermal performance of a typical electric radiant panel. A climatic room was equipped with temperature sensors and heat flow meters to perform a steady state experimental analysis. For the dynamic behavior, a mathematical model was created and compared to a thermographic measurement procedure. The results showed for the steady state an efficiency of energy transformation close to one, while in a transient thermal regime the time constant to reach the steady state condition was slightly faster than the typical ones of hydronic systems.

  8. Analysis of excimer laser radiant exposure effect toward corneal ablation volume at LASIK procedure

    Science.gov (United States)

    Adiati, Rima Fitria; Rini Rizki, Artha Bona; Kusumawardhani, Apriani; Setijono, Heru; Rahmadiansah, Andi

    2016-11-01

    LASIK (Laser Asissted In Situ Interlamelar Keratomilieusis) is a technique for correcting refractive disorders of the eye such as myopia and astigmatism using an excimer laser. This procedure use photoablation technique to decompose corneal tissues. Although preferred due to its efficiency, permanency, and accuracy, the inappropriate amount radiant exposure often cause side effects like under-over correction, irregular astigmatism and problems on surrounding tissues. In this study, the radiant exposure effect toward corneal ablation volume has been modelled through several processes. Data collecting results is laser data specifications with 193 nm wavelength, beam diameter of 0.065 - 0.65 cm, and fluence of 160 mJ/cm2. For the medical data, the myopia-astigmatism value, cornea size, corneal ablation thickness, and flap data are taken. The first modelling step is determining the laser diameter between 0.065 - 0.65 cm with 0.45 cm increment. The energy, power, and intensity of laser determined from laser beam area. Number of pulse and total energy is calculated before the radiant exposure of laser is obtained. Next is to determine the parameters influence the ablation volume. Regression method used to create the equation, and then the spot size is substituted to the model. The validation used is statistic correlation method to both experimental data and theory. By the model created, it is expected that any potential complications can be prevented during LASIK procedures. The recommendations can give the users clearer picture to determine the appropriate amount of radiant exposure with the corneal ablation volume necessary.

  9. Dynamic heat transfer modeling and parametric study of thermoelectric radiant cooling and heating panel system

    International Nuclear Information System (INIS)

    Luo, Yongqiang; Zhang, Ling; Liu, Zhongbing; Wang, Yingzi; Wu, Jing; Wang, Xiliang

    2016-01-01

    Highlights: • Dynamic model of thermoelectric radiant panel system is established. • The internal parameters of thermoelectric module are dynamically calculated in simulation. • Both artificial neural networks model and system model are verified through experiment data. • Optimized system structure is obtained through parametric study. - Abstract: Radiant panel system can optimize indoor thermal comfort with lower energy consumption. The thermoelectric radiant panel (TERP) system is a new and effective prototype of radiant system using thermoelectric module (TEM) instead of conventional water pipes, as heat source. The TERP can realize more stable and easier system control as well as lower initial and operative cost. In this study, an improved system dynamic model was established by combining analytical system model and artificial neural networks (ANN) as well as the dynamic calculation functions of internal parameters of TEM. The double integral was used for the calculation of surface average temperature of TERP. The ANN model and system model were in good agreement with experiment data in both cooling and heating mode. In order to optimize the system design structure, parametric study was conducted in terms of the thickness of aluminum panel and insulation, as well as the arrangement of TEMs on the surface of radiant panel. It was found through simulation results that the optimum thickness of aluminum panel and insulation are respectively around 1–2 mm and 40–50 mm. In addition, TEMs should be uniformly installed on the surface of radiant panel and each TEM should stand at the central position of a square-shaped typical region with length around 0.387–0.548 m.

  10. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.

  11. Electric radiant heating : a hot profitable idea

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2006-09-15

    Due to the high cost of heating oil, natural gas and propane, floor mounted radiant heating systems are now proving to be a cost effective method of heating homes. The systems provide evenly distributed heat across the entire floor area. Unlike hydronic floor systems, radiant floor systems require no maintenance, and are easy to control because no mechanical rooms or boilers are required. The system is comprised of a series of resistant heating cables, a thermostat, and a solid state relay. The cables are installed in a poured concrete pad. Separate temperature control devices are used to heat individual areas of floorspace. Building automation systems can also control the heating system by using simple ambient air- and floor-mounted sensors in conjunction with relays to energize the heating cables. The cost of thermostats and heating cables to heat a standard 2000 square foot home are estimated at $9000.00, with an additional 64 hours of installation costs. It was noted that the systems may prove to be less costly in the long-term than hydronic systems, which require additional boilers, pumps and water treatments. Electric radiant heating can be an even more cost-effective application when used with thermal storage heating applications that use lower-cost off-peak electricity to generate and store heat in concrete floor slabs or ceramic bricks contained in insulated cabinets. It was concluded that radiant heating systems are a viable and cost-effective alternative to expensive hydronic systems, which are costly to install and maintain. 4 figs.

  12. Numerical study of influence of different dispersed components of crystal cloud on transmission of radiant energy

    Science.gov (United States)

    Shefer, Olga

    2017-11-01

    The calculated results of the transmission of visible and infrared radiation by an atmosphere layer involving ensembles of large preferentially oriented crystals and spherical particles are presented. To calculate extinction characteristics, the physical optics method and the Mie theory are applied. Among all atmospheric particles, both the small particles that are commensurable with the wavelength of the incident radiation and the large plates and the columns are distinguished by the most pronounced dependence of the transmission on spectra of radiant energy. The work illustrates features of influence of parameters of the particle size distribution, particle aspect ratios, orientation and particle refractive index, also polarization state of the incident radiation on the transmission. The predominant effect of the plates on the wavelength dependence of the transmission is shown. A separated and cooperative contributes of the large plates and the small volume shape particles to the common transmission by medium are considered.

  13. Tunnel effect wave energy detection

    Science.gov (United States)

    Kaiser, William J. (Inventor); Waltman, Steven B. (Inventor); Kenny, Thomas W. (Inventor)

    1995-01-01

    Methods and apparatus for measuring gravitational and inertial forces, magnetic fields, or wave or radiant energy acting on an object or fluid in space provide an electric tunneling current through a gap between an electrode and that object or fluid in space and vary that gap with any selected one of such forces, magnetic fields, or wave or radiant energy acting on that object or fluid. These methods and apparatus sense a corresponding variation in an electric property of that gap and determine the latter force, magnetic fields, or wave or radiant energy in response to that corresponding variation, and thereby sense or measure such parameters as acceleration, position, particle mass, velocity, magnetic field strength, presence or direction, or wave or radiant energy intensity, presence or direction.

  14. Mathematical modelling, variational formulation and numerical simulation of the energy transfer process in a gray plate in the presence of a thermal radiant source

    International Nuclear Information System (INIS)

    Gama, R.M.S. da.

    1992-05-01

    The energy transfer process in a gray, opaque and rigid plate, heated by an external thermal radiant source, is considered. The source is regarded as a spherical black body, with radius a (a → 0) and uniform heat generation, placed above the plate. A mathematical model is constructed, assuming that the heat transfer from/to the plate takes place by thermal radiation. The obtained mathematical model is nonlinear. Is presented a suitable variational principle which is employed for simulating some particular cases. (author)

  15. Numerical investigation on the convective heat transfer in a spiral coil with radiant heating

    Directory of Open Access Journals (Sweden)

    Đorđević Milan Lj.

    2016-01-01

    Full Text Available The objective of this study was to numerically investigate the heat transfer in spiral coil tube in the laminar, transitional, and turbulent flow regimes. The Archimedean spiral coil was exposed to radiant heating and should represent heat absorber of parabolic dish solar concentrator. Specific boundary conditions represent the uniqueness of this study, since the heat flux upon the tube external surfaces varies not only in the circumferential direction, but also in the axial direction. The curvature ratio of spiral coil varies from 0.029 at the flow inlet to 0.234 at the flow outlet, while the heat transfer fluid is water. The 3-D steady-state transport equations were solved using the Reynolds stress turbulence model. Results showed that secondary flows strongly affect the flow and that the heat transfer is strongly asymmetric, with higher values near the outer wall of spiral. Although overall turbulence levels were lower than in a straight pipe, heat transfer rates were larger due to the curvature-induced modifications of the mean flow and temperature fields. [Projekat Ministarstva nauke Republike Srbije, br. 42006

  16. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  17. Error analysis of thermocouple measurements in the Radiant Heat Facility

    International Nuclear Information System (INIS)

    Nakos, J.T.; Strait, B.G.

    1980-12-01

    The measurement most frequently made in the Radiant Heat Facility is temperature, and the transducer which is used almost exclusively is the thermocouple. Other methods, such as resistance thermometers and thermistors, are used but very rarely. Since a majority of the information gathered at Radiant Heat is from thermocouples, a reasonable measure of the quality of the measurements made at the facility is the accuracy of the thermocouple temperature data

  18. Double Outlet Right Ventricle

    Science.gov (United States)

    ... Right Ventricle Menu Topics Topics FAQs Double Outlet Right Ventricle Double outlet right ventricle (DORV) is a rare form of congenital heart disease. En español Double outlet right ventricle (DORV) is a rare form of congenital ...

  19. Radiant Energy Measurements from a Scaled Jet Engine Axisymmetric Exhaust Nozzle for a Baseline Code Validation Case

    Science.gov (United States)

    Baumeister, Joseph F.

    1994-01-01

    A non-flowing, electrically heated test rig was developed to verify computer codes that calculate radiant energy propagation from nozzle geometries that represent aircraft propulsion nozzle systems. Since there are a variety of analysis tools used to evaluate thermal radiation propagation from partially enclosed nozzle surfaces, an experimental benchmark test case was developed for code comparison. This paper briefly describes the nozzle test rig and the developed analytical nozzle geometry used to compare the experimental and predicted thermal radiation results. A major objective of this effort was to make available the experimental results and the analytical model in a format to facilitate conversion to existing computer code formats. For code validation purposes this nozzle geometry represents one validation case for one set of analysis conditions. Since each computer code has advantages and disadvantages based on scope, requirements, and desired accuracy, the usefulness of this single nozzle baseline validation case can be limited for some code comparisons.

  20. Electric radiant heating or, why are plumbers getting our work?

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech, Toronto, ON (Canada)

    2009-02-15

    Electric radiant heating (ERH) technologies are now being installed in floors as a means of reducing heating costs. The radiant installations have seen a large increase in sales over the last decade, and are now being used in commercial applications. Sales of hydronic ERH systems have increased by 24 per cent over the last year. ERH systems are energy efficient and do not cause drafts. The systems consist of resistant heating cables installed within the floors of a room. The cables are supplied as loose cables and tracks with predetermined spacings or rugged, heavier cable that can be stapled onto wooden subfloors. Program temperature setbacks can be applied on a room-by-room basis. Electric thermal storage systems allow building owners to store heat in the floors and are ideal for use in combination with time-of-use electric metering. Some electric utilities are now promoting the use of electric thermal storage in order to reduce demand during peak times. Thermostats used with the systems should have floor sensors and ambient air sensors to control space heating in conjunction with the floor sensor. It was concluded that electrical contractors who gain knowledge in the application and installation of the systems will tap into a growing revenue stream. 5 figs.

  1. Electric radiant heating or, why are plumbers getting our work?

    International Nuclear Information System (INIS)

    Lemieux, G.

    2009-01-01

    Electric radiant heating (ERH) technologies are now being installed in floors as a means of reducing heating costs. The radiant installations have seen a large increase in sales over the last decade, and are now being used in commercial applications. Sales of hydronic ERH systems have increased by 24 per cent over the last year. ERH systems are energy efficient and do not cause drafts. The systems consist of resistant heating cables installed within the floors of a room. The cables are supplied as loose cables and tracks with predetermined spacings or rugged, heavier cable that can be stapled onto wooden subfloors. Program temperature setbacks can be applied on a room-by-room basis. Electric thermal storage systems allow building owners to store heat in the floors and are ideal for use in combination with time-of-use electric metering. Some electric utilities are now promoting the use of electric thermal storage in order to reduce demand during peak times. Thermostats used with the systems should have floor sensors and ambient air sensors to control space heating in conjunction with the floor sensor. It was concluded that electrical contractors who gain knowledge in the application and installation of the systems will tap into a growing revenue stream. 5 figs

  2. Human response to local convective and radiant cooling in a warm environment

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Krejcirikova, Barbora; Kaczmarczyk, Jan

    2013-01-01

    The response of 24 human subjects to local convective cooling, radiant cooling, and combined radiant and convective cooling was studied at 28°C and 50% relative humidity. The local cooling devices used were (1) a tabletop cooling fan, (2) personalized ventilation providing a stream of clean air, (3...

  3. Energy efficiency of electrical infrared heating elements

    International Nuclear Information System (INIS)

    Brown, K.J.; Farrelly, R.; O’Shaughnessy, S.M.; Robinson, A.J.

    2016-01-01

    Highlights: • Characterization of the radiant energy efficiency of infrared heating elements. • Performed for a commercially available ceramic heater element for two cases. • Total radiant power and net radiant efficiency is computed. • Radiant efficiencies are strongly dependant on the input power to the element. • In-plane efficiencies depend on the distance from the heater. - Abstract: A measurement system has been designed to characterize the radiant energy efficiency of infrared heating elements. The system also allows for measurement of the radiant heat flux distribution emitted from radiant heater assemblies. To facilitate these, a 6-axis robotic arm is fitted with a Schmidt–Boelter radiant heat flux gauge. A LabVIEW interface operates the robot and positions the sensor in the desired location and subsequently acquires the desired radiant heat flux measurement. To illustrate the functionality of the measurement system and methodology, radiant heat flux distributions and efficiency calculations are performed for a commercially available ceramic heater element for two cases. In the first, a spherical surface is traced around the entire heater assembly and the total radiant power and net radiant efficiency is computed. In the second, 50 cm × 50 cm vertical planes are traced parallel to the front face of the heater assembly at distances between 10 cm and 50 cm and the in-plane power and efficiencies are computed. The results indicate that the radiant efficiencies are strongly dependant on the input power to the element and, for the in-plane efficiencies, depend on the distance from the heater.

  4. Present and projected future mean radiant temperature for three European cities

    Science.gov (United States)

    Thorsson, Sofia; Rayner, David; Lindberg, Fredrik; Monteiro, Ana; Katzschner, Lutz; Lau, Kevin Ka-Lun; Campe, Sabrina; Katzschner, Antje; Konarska, Janina; Onomura, Shiho; Velho, Sara; Holmer, Björn

    2017-09-01

    Present-day and projected future changes in mean radiant temperature, T mrt in one northern, one mid-, and one southern European city (represented by Gothenburg, Frankfurt, and Porto), are presented, and the concept of hot spots is adopted. Air temperature, T a , increased in all cities by 2100, but changes in solar radiation due to changes in cloudiness counterbalanced or exacerbated the effects on T mrt. The number of days with high T mrt in Gothenburg was relatively unchanged at the end of the century (+1 day), whereas it more than doubled in Frankfurt and tripled in Porto. The use of street trees to reduce daytime radiant heat load was analyzed using hot spots to identify where trees could be most beneficial. Hot spots, although varying in intensity and frequency, were generally confined to near sunlit southeast-southwest facing walls, in northeast corner of courtyards, and in open spaces in all three cities. By adding trees in these spaces, the radiant heat load can be reduced, especially in spaces with no or few trees. A set of design principles for reducing the radiant heat load is outlined based on these findings and existing literature.

  5. Fixed, low radiant exposure vs. incremental radiant exposure approach for diode laser hair reduction: a randomized, split axilla, comparative single-blinded trial.

    Science.gov (United States)

    Pavlović, M D; Adamič, M; Nenadić, D

    2015-12-01

    Diode lasers are the most commonly used treatment modalities for unwanted hair reduction. Only a few controlled clinical trials but not a single randomized controlled trial (RCT) compared the impact of various laser parameters, especially radiant exposure, onto efficacy, tolerability and safety of laser hair reduction. To compare the safety, tolerability and mid-term efficacy of fixed, low and incremental radiant exposures of diode lasers (800 nm) for axillary hair removal, we conducted an intrapatient, left-to-right, patient- and assessor-blinded and controlled trial. Diode laser (800 nm) treatments were evaluated in 39 study participants (skin type II-III) with unwanted axillary hairs. Randomization and allocation to split axilla treatments were carried out by a web-based randomization tool. Six treatments were performed at 4- to 6-week intervals with study subjects blinded to the type of treatment. Final assessment of hair reduction was conducted 6 months after the last treatment by means of blinded 4-point clinical scale using photographs. The primary endpoint was reduction in hair growth, and secondary endpoints were patient-rated tolerability and satisfaction with the treatment, treatment-related pain and adverse effects. Excellent reduction in axillary hairs (≥ 76%) at 6-month follow-up visit after receiving fixed, low and incremental radiant exposure diode laser treatments was obtained in 59% and 67% of study participants respectively (Z value: 1.342, P = 0.180). Patients reported lower visual analogue scale (VAS) pain score on the fixed (4.26) than on the incremental radiant exposure side (5.64) (P diode laser treatments were less painful and better tolerated. © 2015 European Academy of Dermatology and Venereology.

  6. Three-dimensional simulation of super-radiant Smith-Purcell radiation

    International Nuclear Information System (INIS)

    Li, D.; Imasaki, K.; Yang, Z.; Park, Gun-Sik

    2006-01-01

    A simulation of coherent and super-radiant Smith-Purcell radiation is performed in the gigahertz regime using a three-dimensional particle-in-cell code. The simulation model supposes a rectangular grating to be driven by a single electron bunch and a train of periodic bunches, respectively. The true Smith-Purcell radiation is distinguished from the evanescent wave, which has an angle independent frequency lower than the minimum allowed Smith-Purcell frequency. We also find that the super-radiant radiations excited by periodic bunches are emitted at higher harmonics of the bunching frequency and at the corresponding Smith-Purcell angles

  7. Alcohol outlets, social disorganization, and robberies: accounting for neighborhood characteristics and alcohol outlet types.

    Science.gov (United States)

    Snowden, Aleksandra J; Freiburger, Tina L

    2015-05-01

    We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Finite-elements modeling of radiant heat transfers between mobile surfaces; Modelisation par elements finis de transferts radiatifs entre surfaces mobiles

    Energy Technology Data Exchange (ETDEWEB)

    Daurelle, J V; Cadene, V; Occelli, R [Universite de Provence, 13 - Marseille (France)

    1997-12-31

    In the numerical modeling of thermal industrial problems, radiant heat transfers remain difficult to take into account and require important computer memory and long computing time. These difficulties are enhanced when radiant heat transfers are coupled with finite-elements diffusive heat transfers because finite-elements architecture is complex and requires a lot of memory. In the case of radiant heat transfers along mobile boundaries, the methods must be optimized. The model described in this paper concerns the radiant heat transfers between diffuse grey surfaces. These transfers are coupled with conduction transfers in the limits of the diffusive opaque domain. 2-D and 3-D geometries are analyzed and two configurations of mobile boundaries are considered. In the first configuration, the boundary follows the deformation of the mesh, while in the second, the boundary moves along the fixed mesh. Matter displacement is taken into account in the term of transport of the energy equation, and an appropriate variation of the thermophysical properties of the transition elements between the opaque and transparent media is used. After a description of the introduction of radiative limit conditions in a finite-elements thermal model, the original methods used to optimize calculation time are explained. Two examples of application illustrate the approach used. The first concerns the modeling of radiant heat transfers between fuel rods during a reactor cooling accident, and the second concerns the study of heat transfers inside the air-gap of an electric motor. The method of identification of the mobile surface on the fixed mesh is described. (J.S.) 12 refs.

  9. Finite-elements modeling of radiant heat transfers between mobile surfaces; Modelisation par elements finis de transferts radiatifs entre surfaces mobiles

    Energy Technology Data Exchange (ETDEWEB)

    Daurelle, J.V.; Cadene, V.; Occelli, R. [Universite de Provence, 13 - Marseille (France)

    1996-12-31

    In the numerical modeling of thermal industrial problems, radiant heat transfers remain difficult to take into account and require important computer memory and long computing time. These difficulties are enhanced when radiant heat transfers are coupled with finite-elements diffusive heat transfers because finite-elements architecture is complex and requires a lot of memory. In the case of radiant heat transfers along mobile boundaries, the methods must be optimized. The model described in this paper concerns the radiant heat transfers between diffuse grey surfaces. These transfers are coupled with conduction transfers in the limits of the diffusive opaque domain. 2-D and 3-D geometries are analyzed and two configurations of mobile boundaries are considered. In the first configuration, the boundary follows the deformation of the mesh, while in the second, the boundary moves along the fixed mesh. Matter displacement is taken into account in the term of transport of the energy equation, and an appropriate variation of the thermophysical properties of the transition elements between the opaque and transparent media is used. After a description of the introduction of radiative limit conditions in a finite-elements thermal model, the original methods used to optimize calculation time are explained. Two examples of application illustrate the approach used. The first concerns the modeling of radiant heat transfers between fuel rods during a reactor cooling accident, and the second concerns the study of heat transfers inside the air-gap of an electric motor. The method of identification of the mobile surface on the fixed mesh is described. (J.S.) 12 refs.

  10. Radiant heat increases piglets’ use of the heated creep area on the critical days after birth

    DEFF Research Database (Denmark)

    Larsen, Mona Lilian Vestbjerg; Thodberg, Karen; Pedersen, Lene Juul

    2017-01-01

    The aim of the present study was to investigate how piglets’ use of a creep area is affected by using radiant heat compared to an incandescent light bulb. It was hypothesised that radiant heat would increase the use of the creep area. Twenty litters were randomly assigned to one of two heat sources...... in the creep area: (1) an incandescent light bulb (STANDARD, n=10) or (2) a radiant heat source (RADIANT, n=10) with five of each type of heat source in each of two batches. Observations on piglets’ position in the pen were made by scan sampling every ten minutes in a 4-hour period from 1100 to 1500 h on day 1......–7, 14 and 21 post partum. A higher percentage of piglets in the creep area was seen for RADIANT litters compared to STANDARD litters on day 2 (P=0.002) and day 3 (P=0.005), and percentage of piglets in the creep area increased for RADIANT litters from day 1 to 2 (P

  11. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large ......-uniformity air distribution and further led to the draught problem in the occupied zone. This system was recommended to apply in the small offices instead of large, open spaces....

  12. Solar hybrid cooling system for high-tech offices in subtropical climate - Radiant cooling by absorption refrigeration and desiccant dehumidification

    International Nuclear Information System (INIS)

    Fong, K.F.; Chow, T.T.; Lee, C.K.; Lin, Z.; Chan, L.S.

    2011-01-01

    Highlights: → A solar hybrid cooling system is proposed for high-tech offices in subtropical climate. → An integration of radiant cooling, absorption refrigeration and desiccant dehumidification. → Year-round cooling and energy performances were evaluated through dynamic simulation. → Its annual primary energy consumption was lower than conventional system up to 36.5%. → The passive chilled beams were more energy-efficient than the active chilled beams. - Abstract: A solar hybrid cooling design is proposed for high cooling load demand in hot and humid climate. For the typical building cooling load, the system can handle the zone cooling load (mainly sensible) by radiant cooling with the chilled water from absorption refrigeration, while the ventilation load (largely latent) by desiccant dehumidification. This hybrid system utilizes solar energy for driving the absorption chiller and regenerating the desiccant wheel. Since a high chilled water temperature generated from the absorption chiller is not effective to handle the required latent load, desiccant dehumidification is therefore involved. It is an integration of radiant cooling, absorption refrigeration and desiccant dehumidification, which are powered up by solar energy. In this study, the application potential of the solar hybrid cooling system was evaluated for the high-tech offices in the subtropical climate through dynamic simulation. The high-tech offices are featured with relatively high internal sensible heat gains due to the intensive office electric equipment. The key performance indicators included the solar fraction and the primary energy consumption. Comparative study was also carried out for the solar hybrid cooling system using two common types of chilled ceilings, the passive chilled beams and active chilled beams. It was found that the solar hybrid cooling system was technically feasible for the applications of relatively higher cooling load demand. The annual primary energy

  13. Linearization of the interaction principle: Analytic Jacobians in the 'Radiant' model

    International Nuclear Information System (INIS)

    Spurr, R.J.D.; Christi, M.J.

    2007-01-01

    In this paper we present a new linearization of the Radiant radiative transfer model. Radiant uses discrete ordinates for solving the radiative transfer equation in a multiply-scattering anisotropic medium with solar and thermal sources, but employs the adding method (interaction principle) for the stacking of reflection and transmission matrices in a multilayer atmosphere. For the linearization, we show that the entire radiation field is analytically differentiable with respect to any surface or atmospheric parameter for which we require Jacobians (derivatives of the radiance field). Derivatives of the discrete ordinate solutions are based on existing methods developed for the LIDORT radiative transfer models. Linearization of the interaction principle is completely new and constitutes the major theme of the paper. We discuss the application of the Radiant model and its linearization in the Level 2 algorithm for the retrieval of columns of carbon dioxide as the main target of the Orbiting Carbon Observatory (OCO) mission

  14. Experimental evaluation of heat transfer coefficients between radiant ceiling and room

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2009-01-01

    The heat transfer coefficients between radiant surfaces and room are influenced by several parameters: surfaces temperature distributions, internal gains, air movements. The aim of this paper is to evaluate the heat transfer coefficients between radiant ceiling and room in typical conditions...... of occupancy of an office or residential building. Internal gains were therefore simulated using heated cylinders and heat losses using cooled surfaces. Evaluations were developed by means of experimental tests in an environmental chamber. Heat transfer coefficient may be expressed separately for radiation...

  15. Radiometric measurements of wall temperatures in the 800 K to 1150 K range for a quartz radiant heating tube

    International Nuclear Information System (INIS)

    Blevins, L.G.; Sivathanu, Y.R.; Gore, J.P.; Shahien, M.A.

    1995-01-01

    Many industrial applications require heat transfer to a load in an inert environment, which can be achieved by using gas-fired radiant tubes. A radiant tube consists of a flame confined in a cylindrical metal or ceramic chamber. The flame heats the tube wall, which in turn radiates to the load. One important characteristic of radiant heating tubes is wall temperature uniformity. Numerical models of radiant tubes have been used to predict wall temperatures, but there is a lack of experimental data for validation. Recently, Namazian et al., Singh and Gorski, and Peters et al. have measured wall temperature profiles of radiant tubes using thermocouples. 13 refs., 3 figs

  16. 16 CFR Figure 3 to Subpart A of... - Flooring Radiant Tester Schematic Side Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Tester Schematic Side Elevation 3 Figure 3 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 3 Figure 3 to Subpart A of Part 1209—Flooring Radiant Tester Schematic Side...

  17. Study on coal char ignition by radiant heat flux.

    Science.gov (United States)

    Korotkikh, A. G.; Slyusarskiy, K. V.

    2017-11-01

    The study on coal char ignition by CO2-continuous laser was carried out. The coal char samples of T-grade bituminous coal and 2B-grade lignite were studied via CO2-laser ignition setup. Ignition delay times were determined at ambient condition in heat flux density range 90-200 W/cm2. The average ignition delay time value for lignite samples were 2 times lower while this difference is larger in high heat flux region and lower in low heat flux region. The kinetic constants for overall oxidation reaction were determined using analytic solution of simplified one-dimensional heat transfer equation with radiant heat transfer boundary condition. The activation energy for lignite char was found to be less than it is for bituminous coal char by approximately 20 %.

  18. An experimental study of thermal comfort at different combinations of air and mean radiant temperature

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.

    2009-01-01

    It is often discussed if a person prefers a low air temperature (ta) and a high mean radiant temperature (tr), vice-versa or it does not matter as long as the operative temperature is acceptable. One of the hypotheses is that it does not matter for thermal comfort but for perceived air quality......, a lower air temperature is preferred. This paper presents an experimental study with 30 human subjects exposed to three different combinations of air- and mean radiant temperature with an operative temperature around 23 °C. The subjects gave subjective evaluations of thermal comfort and perceived air...... quality during the experiments. The PMV-index gave a good estimation of thermal sensation vote (TSV) when the air and mean radiant temperature were the same. In the environment with different air- and mean radiant temperatures, a thermal comfort evaluation shows an error up to 1 scale unit on the 7-point...

  19. Super-radiant Smith–Purcell radiation from periodic line charges

    International Nuclear Information System (INIS)

    Li, D.; Hangyo, M.; Tsunawaki, Y.; Yang, Z.; Wei, Y.; Miyamoto, S; Asakawa, M.R.; Imasaki, K.

    2012-01-01

    Smith–Purcell radiation occurs when an electron passes close to the surface of a metallic grating. The radiation becomes coherent when the length of the electron bunch is smaller than the wavelength of the radiation. A train of periodic bunches can enhance the spectral intensity by changing the angular and spectral distribution of the radiation. This is called super-radiant Smith–Purcell radiation, and has been observed in experiments and particle-in-cell simulations. In this paper, we introduce a new method to study this effect by calculating the reflected waves of an incident evanescent wave from periodic line charges. The reflection coefficients are numerically computed, and the spectral distributions of the super-radiant radiation are demonstrated. These analytical results are in agreement with those obtained through part-in-cell simulations.

  20. Load calculations of radiant cooling systems for sizing the plant

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    The aim of this study was, by using a building simulation software, to prove that a radiant cooling system should not be sized based on the maximum cooling load but at a lower value. For that reason six radiant cooling models were simulated with two control principles using 100%, 70% and 50......% of the maximum cooling load. It was concluded that all tested systems were able to provide an acceptable thermal environment even when the 50% of the maximum cooling load was used. From all the simulated systems the one that performed the best under both control principles was the ESCS ceiling system. Finally...... it was proved that ventilation systems should be sized based on the maximum cooling load....

  1. Cooling load calculation by the radiant time series method - effect of solar radiation models

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alexandre M.S. [Universidade Estadual de Maringa (UEM), PR (Brazil)], E-mail: amscosta@uem.br

    2010-07-01

    In this work was analyzed numerically the effect of three different models for solar radiation on the cooling load calculated by the radiant time series' method. The solar radiation models implemented were clear sky, isotropic sky and anisotropic sky. The radiant time series' method (RTS) was proposed by ASHRAE (2001) for replacing the classical methods of cooling load calculation, such as TETD/TA. The method is based on computing the effect of space thermal energy storage on the instantaneous cooling load. The computing is carried out by splitting the heat gain components in convective and radiant parts. Following the radiant part is transformed using time series, which coefficients are a function of the construction type and heat gain (solar or non-solar). The transformed result is added to the convective part, giving the instantaneous cooling load. The method was applied for investigate the influence for an example room. The location used was - 23 degree S and 51 degree W and the day was 21 of January, a typical summer day in the southern hemisphere. The room was composed of two vertical walls with windows exposed to outdoors with azimuth angles equals to west and east directions. The output of the different models of solar radiation for the two walls in terms of direct and diffuse components as well heat gains were investigated. It was verified that the clear sky exhibited the less conservative (higher values) for the direct component of solar radiation, with the opposite trend for the diffuse component. For the heat gain, the clear sky gives the higher values, three times higher for the peek hours than the other models. Both isotropic and anisotropic models predicted similar magnitude for the heat gain. The same behavior was also verified for the cooling load. The effect of room thermal inertia was decreasing the cooling load during the peak hours. On the other hand the higher thermal inertia values are the greater for the non peak hours. The effect

  2. Optimum pulse duration and radiant exposure for vascular laser therapy of dark port-wine skin: a theoretical study

    International Nuclear Information System (INIS)

    Tunnell, James W.; Anvari, Bahman; Wang, Lihong V.

    2003-01-01

    Laser therapy for cutaneous hypervascular malformations such as port-wine stain birthmarks is currently not feasible for dark-skinned individuals. We study the effects of pulse duration, radiant exposure, and cryogen spray cooling (CSC) on the thermal response of skin, using a Monte Carlo based optical-thermal model. Thermal injury to the epidermis decreases with increasing pulse duration during irradiation at a constant radiant exposure; however, maintaining vascular injury requires that the radiant exposure also increase. At short pulse durations, only a minimal increase in radiant exposure is necessary for a therapeutic effect to be achieved because thermal diffusion from the vessels is minimal. However, at longer pulse durations the radiant exposure must be greatly increased. There exists an optimum pulse duration at which minimal damage to the epidermis and significant injury within the targeted vasculature occur. For example, the model predicts optimum pulse durations of approximately 1.5, 6, and 20 ms for vessel diameters of 40, 80, and 120 μm, respectively. Optimization of laser pulse duration and radiant exposure in combination with CSC may offer a means to treat cutaneous lesions in dark-skinned individuals

  3. Stratification in SNR-300 outlet plenum

    International Nuclear Information System (INIS)

    Reinders, R.

    1983-01-01

    In the inner outlet plenum of the SNR-300 under steady state conditions a large toroidal vortex is expected. The main flow passes through the gap between dipplate and shield vessel to the outer annular space. Only 3% of the flow pass the 24 emergency cooling holes, situated in the shield vessel. The sodium leaves the reactor tank through the 3 symmetrically arranged outlet nozzles. For a scram flow rates and temperatures are decreased simultaneously, so it is expected, that stratification occurs in the inner outlet plenum. A measure of stratification effects is the Archimedes Number Ar, which is the relation of buoyancy forces (negative) to kinetic energy. (The Archimedes Number is nearly identical with the Richardson Number). For values Ar>1 stratification can occur. Under the assumption of stratification the code TIRE was developed, which is only applicable for the period of time after some 50 sec after scram. This code serves for long term calculations. As the equations are very simple, it is a very fast code which gives the possibility to calculate transients for some hours real time. This code mainly has to take into account the pressure difference between inner plenum and outlet annulus caused by geodatic pressure. That force is in equilibrium with the pressure drop over the gap and holes in the shield vessel. For more detailed calculations of flow pattern and temperature distribution the code MIX and INKO 2T are applied. MIX was developed and validated at ANL, INKO 2T is a development of INTERATOM. INKO 2T is under validation. Mock up experiments were carried out with water to simulate the transient behavior of the SNR-300 outlet plenum. Calculations obtained by INKO 2T for steady state and the transient are shown for the flow pattern. Results of measurements also prove that stratification begins after about 30 sec. Measurements and detailed calculations show that it is admissible to use the code TIRE for the long term calculations. Calculations for a scram

  4. Out-of-home food outlets and area deprivation: case study in Glasgow, UK

    Directory of Open Access Journals (Sweden)

    Cummins Steven

    2005-10-01

    Full Text Available Abstract Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways, and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2 and lowest in the second most deprived quintile (Q4. Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84 in Q1, 0.50 (CI 0.31 – 0.80 in Q4 and 0.61 (CI 0.38 – 0.98 in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'.

  5. 14 CFR 23.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 23.977 Section 23.977... tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This... damage any fuel system component. (b) The clear area of each fuel tank outlet strainer must be at least...

  6. Evaluation of Various Retrofitting Concepts of Building Envelope for Offices Equipped with Large Radiant Ceiling Panels by Dynamic Simulations

    Directory of Open Access Journals (Sweden)

    Sabina Jordan

    2015-09-01

    Full Text Available In order to achieve significant savings in energy and an improved level of thermal comfort in retrofitted existing buildings, specific retrofitting concepts that combine new technologies and design need to be developed and implemented. Large radiant surfaces systems are now among the most promising future technologies to be used both in retrofitted and in new low-energy buildings. These kinds of systems have been the topic of several studies dealing with thermal comfort and energy utilization, but some specific issues concerning their possible use in various concepts for retrofitting are still poorly understood. In the present paper, some results of dynamic simulations, with the transient system simulation tool (TRNSYS model, of the retrofitted offices equipped with radiant ceiling panels are presented and thoroughly analysed. Based on a precise comparison of the results of these simulations with actual measurements in the offices, certain input data for the model were added, so that the model was consequently validated. The model was then applied to the evaluation of various concepts of building envelopes for office retrofitting. By means of dynamic simulations of indoor environment it was possible to determine the benefits and limitations of individual retrofitting concepts. Some specific parameters, which are relevant to these concepts, were also identified.

  7. Automatic drawing and CAD actualization in processing data of radiant sampling in physics prospect

    International Nuclear Information System (INIS)

    Liu Jinsheng

    2010-01-01

    In this paper discussed a method of processing radiant sampling data with computer. By this method can get expain the curve of radiant sampling data, and we can combine mineral masses and analyse and calculate them, then record the result on Notebook. There are many merites of this method: easy to learn, simple to use, high efficient. It adapts to all sorts of mines. (authors)

  8. Automatic drawing and cad actualiztion in processing data of radiant sampling in physics prospect

    International Nuclear Information System (INIS)

    Liu Jinsheng

    2010-01-01

    In this paper discussed a method of processing radiant sampling data with computer. By this method can get explain the curve of radiant sampling data, and we can combine mineral masses and analyses and calculate them, then record the result on Notebook. There are many merites of this method: easy to learn, simple to use, high efficient. It adapts to all sorts of mines. (authors)

  9. Laboratory determination of normal operating flow rates with enlarged outlet fittings -- BDF reactors

    Energy Technology Data Exchange (ETDEWEB)

    Waters, E.D.

    1960-02-02

    Experiments have been conducted in the Hydraulics Laboratory, at the request of IPD`s Mechanical Development-A Operation, to determine the energy losses of various enlarged outlet fitting combinations. These experiments were conducted an steady state runs and allow the determination of the normal operating point (flow rate) of a reactor process channel under selected conditions of front header pressure and fuel charge. No attempt is made to make a mechanical or economic evaluation of the particular fitting combinations, although observations were noted which might bear on this evaluation. It is very important for the reader to bear in mind that changing outlet fittings will definitely affect the reactor tube power limits and outlet vater temperature limits. The size of the outlet fittings largely determines the present outlet temperature limits of the old reactors. The flow characteristics of these present fittings cause some degree of pressurization to suppress boiling on the fuel charge and also cause dual Panellit trip protection for certain flow changes and for power surges. Enlargement of the outlet fittings may actually reduce the allowable outlet coolant temperature limits. Since these effects cannot be determined on the apparatus used in these experiments, a complete discussion of this point is not included in this report. However, the seriousness of these effects should be known and carefully analyzed before a final selection of enlarged outlet fittings in made. This report will be one of a series. New reports in the series will be issued as data are obtained for other such outlet fitting combinations or for new concepts of outlet fitting assemblies such as the new nozzle being developed by C. E. Trantz for use on F-reactor stuck gunbarrel tubes.

  10. Alcohol Outlet Density and Intimate Partner Violence in a Nonmetropolitan College Town: Accounting for Neighborhood Characteristics and Alcohol Outlet Types.

    Science.gov (United States)

    Snowden, Aleksandra J

    2016-01-01

    There is a growing evidence of an ecological association between alcohol outlet density and intimate partner violence. It is reasonable to assume, however, that not all types of alcohol outlets contribute equally to criminal behavior, and to date, most ecological studies have been of large urban cities. Using Bloomington, Indiana, block groups as units of analysis and controlling for several structural characteristics associated with violence rates, I estimated spatially lagged regression models to determine if the variation in alcohol outlet density, including total outlets and disaggregating by on- and off-premise outlets, is related to intimate partner violence density. Results suggested that total alcohol outlet density and off-premise alcohol outlet density were significantly associated with intimate partner violence density. On-premise alcohol outlet density was not significantly associated with intimate partner violence density. These results not only extend the geographic scope of this relationship beyond large metropolitan areas but also have important policy implications.

  11. Electric radiant heating: A hot item in home comfort

    Energy Technology Data Exchange (ETDEWEB)

    Lemieux, G. [Britech Corp., Toronto, ON (Canada)

    2003-12-01

    Electric radiant heating as a floor warming system and its growing popularity in home comfort are discussed. Price can be as low as $2.00 per square foot; cost of operation may be as little as 30 cents per square foot per year, depending on time of use and local hydro rates. The use of radiant cable heating is said to have surged in popularity; it provides the same warmth and comfort as more expensive hydronic systems. Radiant cable is simple and inexpensive to install since unlike hydronic systems, it requires no complicated mechanical system with boiler, heat exchanger, valves, pumps and extensive controls. Nevertheless, prospective end users are warned to make sure that the cable is sturdy, tough, has multiple layers of protection with a thick grounding system and conductor core. In addition to heating floors, electric heating cables can also be used for snow and ice control and for melting in driveways and gutters. In these type of installations heavy duty cables are used which are installed under asphalt, concrete or interlocking stones. Thirty watts per square foot per hour is the typical requirement for melting snow and ice. Based on average electricity prices in Ontario, melting snow on an 800 square foot driveway would cost about $2.20 per hour. Assuming five hours for the system to clear the driveway, installing a heating system under the driveway could be an economically viable solution for the home owner, providing freedom from ice, the inconvenience of shovelling snow, and saving time and money.

  12. The relationship between radiant heat, air temperature and thermal comfort at rest and exercise.

    Science.gov (United States)

    Guéritée, Julien; Tipton, Michael J

    2015-02-01

    The aims of the present work were to investigate the relationships between radiant heat load, air velocity and body temperatures with or without coincidental exercise to determine the physiological mechanisms that drive thermal comfort and thermoregulatory behaviour. Seven male volunteers wearing swimming trunks in 18°C, 22°C or 26°C air were exposed to increasing air velocities up to 3 m s(-1) and self-adjusted the intensity of the direct radiant heat received on the front of the body to just maintain overall thermal comfort, at rest or when cycling (60 W, 60 rpm). During the 30 min of the experiments, skin and rectal temperatures were continuously recorded. We hypothesized that mean body temperature should be maintained stable and the intensity of the radiant heat and the mean skin temperatures would be lower when cycling. In all conditions, mean body temperature was lower when facing winds of 3 m s(-1) than during the first 5 min, without wind. When facing winds, in all but the 26°C air, the radiant heat was statistically higher at rest than when exercising. In 26°C air mean skin temperature was lower at rest than when exercising. No other significant difference was observed. In all air temperatures, high correlation coefficients were observed between the air velocity and the radiant heat load. Other factors that we did not measure may have contributed to the constant overall thermal comfort status despite dropping mean skin and body temperatures. It is suggested that the allowance to behaviourally adjust the thermal environment increases the tolerance of cold discomfort. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Cooling load calculations of radiant and all-air systems for commercial buildings

    DEFF Research Database (Denmark)

    Bourdakis, Eleftherios; Bauman, Fred; Schiavon, Stefano

    The authors simulated in TRNSYS three radiant systems coupled with a 50% sized variable air volume (VAV) system and a 50% sized all-air VAV system with night ventilation. The objective of this study was to identify the differences in the cooling load profiles of the examined systems when they are......The authors simulated in TRNSYS three radiant systems coupled with a 50% sized variable air volume (VAV) system and a 50% sized all-air VAV system with night ventilation. The objective of this study was to identify the differences in the cooling load profiles of the examined systems when...

  14. Radiant heat loss, an unexploited path for heat stress reduction in shaded cattle.

    Science.gov (United States)

    Berman, A; Horovitz, T

    2012-06-01

    Reducing thermal radiation on shaded animals reduces heat stress independently of other means of stress relief. Radiant heat exchange was estimated as a function of climate, shade structure, and animal density. Body surface portion exposed to radiant sources in shaded environments was determined by geometrical relations to determine angles of view of radiation sources (roof underside, sky, sun-exposed ground, shaded ground) on the animal's surface. The relative representation of environment radiation sources on the body surface was determined. Animal thermal radiation balance was derived from radiant heat gained from radiation sources (including surrounding animals) and that lost from the animal surface. The animal environment was assumed to have different shade dimensions and temperatures. These were summed to the radiant heat balance of the cow. The data formed served to estimate the effect of changes in intensity of radiation sources, roof and shaded surface dimensions, and animal density on radiant heat balance (Rbal) of cattle. Roof height effect was expressed by effect of roof temperature on Rbal. Roof underside temperature (35 to 75°C) effect on Rbal was reduced by roof height. If roof height were 4m, an increase in its underside temperature from 35 to 75°C would increase mean Rbal from -63 to -2 W·m⁻², whereas if roof height were 10 m, Rbal would only increase from -99 to -88 W·m⁻². A hot ground temperature increase from 35 to 65°C reduced mean Rbal heat loss from -45 to 3 W·m⁻². Increasing the surface of the shaded area had only a minor effect on Rbal and on the effect of hot ground on Rbal. Increasing shade roof height reduced the effect of roof temperature on Rbal to minor levels when height was > 8m. Increasing the roof height from 4 to 10 m decreased Rbal from -32 to -94 W·m⁻². Increasing indirect radiation from 100 to 500 W·m⁻² was associated with an increase in Rbal from -135 to +23 W·m⁻². Their combined effects were lower

  15. Effects of cryogen spray cooling and high radiant exposures on selective vascular injury during laser irradiation of human skin.

    Science.gov (United States)

    Tunnell, James W; Chang, David W; Johnston, Carol; Torres, Jorge H; Patrick, Charles W; Miller, Michael J; Thomsen, Sharon L; Anvari, Bahman

    2003-06-01

    Increasing radiant exposure offers a means to increase treatment efficacy during laser-mediated treatment of vascular lesions, such as port-wine stains; however, excessive radiant exposure decreases selective vascular injury due to increased heat generation within the epidermis and collateral damage to perivascular collagen. To determine if cryogen spray cooling could be used to maintain selective vascular injury (ie, prevent epidermal and perivascular collagen damage) when using high radiant exposures (16-30 J/cm2). Observational study. Academic hospital and research laboratory. Twenty women with normal abdominal skin (skin phototypes I-VI). Skin was irradiated with a pulsed dye laser (wavelength = 585 nm; pulse duration = 1.5 milliseconds; 5-mm-diameter spot) using various radiant exposures (8-30 J/cm2) without and with cryogen spray cooling (50- to 300-millisecond cryogen spurts). Hematoxylin-eosin-stained histologic sections from each irradiated site were examined for the degree of epidermal damage, maximum depth of red blood cell coagulation, and percentage of vessels containing perivascular collagen coagulation. Long cryogen spurt durations (>200 milliseconds) protected the epidermis in light-skinned individuals (skin phototypes I-IV) at the highest radiant exposure (30 J/cm2); however, epidermal protection could not be achieved in dark-skinned individuals (skin phototypes V-VI) even at the lowest radiant exposure (8 J/cm2). The red blood cell coagulation depth increased with increasing radiant exposure (to >2.5 mm for skin phototypes I-IV and to approximately 1.2 mm for skin phototypes V-VI). In addition, long cryogen spurt durations (>200 milliseconds) prevented perivascular collagen coagulation in all skin types. Cryogen spurt durations much longer than those currently used in therapy (>200 milliseconds) may be clinically useful for protecting the epidermis and perivascular tissues when using high radiant exposures during cutaneous laser therapies

  16. Measurement of radiant properties of ceramic foam

    International Nuclear Information System (INIS)

    Hoornstra, J.; Turecky, M.; Maatman, D.

    1994-07-01

    An experimental facility is described for the measurement of the normal spectral and total emissivity and transmissivity of semi-transparent materials in the temperature range of 600 C to 1200 C. The set-up was used for the measurement of radiation properties of highly porous ceramic foam which is used in low NO x radiant burners. Emissivity and transmissivity data were measured and are presented for coated and uncoated ceramic foam of different thicknesses. (orig.)

  17. Thermal Conditions in a Simulated Office Environment with Convective and Radiant Cooling Systems

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2013-01-01

    velocity and turbulent intensity were measured and draft rate levels calculated in the room. Manikin-based equivalent temperature (MBET) was determined by two thermal manikins to identify the impact of the local thermal conditions generated by the studied systems on occupants’ thermal comfort. The results......The thermal conditions in a two person office room were measured with four air conditioning systems: chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition mounted local radiant cooling panels with mixing...

  18. Characteristics of infrared thermometers manufactured in Japan and calibration methods for sky radiant emittance

    International Nuclear Information System (INIS)

    Wang, X.; Horiguchi, I.; Machimura, T.

    1993-01-01

    Infrared thermometers to measure surface temperature have been increasingly adopted in recent years. The characteristics of the IR thermometer, however, are not well known.IR thermometers manufactured in Japan systematically adjust for ambient radiation based on the internal temperature of the thermometer. If, therefore, there is a large difference between the internal temperature of the IR thermometer and the apparent temperature associated with the surrounding radiation, a large error will be induced into the measured surface temperature.The purpose of our research was to determine the characteristics and measurement errors of IR thermometers. Experiments were performed with regard to the following items: (1) Measurement errors related to the internal temperature of the IR thermometer. (2) Linearity of the output signal of the IR thermometer. (3) Response of the output signal to changes in the emissivity setting. (4) Effect of sky radiant emittance on the measured surface temperature. (5) Calibration method for the terrestrial surface.The following is a summary of the results: Measurement error is affected by the internal temperature of the IR thermometer. Measurement accuracy is improved with a controlled internal temperature of 20-30°C. The measurement error becomes larger at emissivity settings under 0.7.The measurement error outdoors was not proportional to the downward longwave radiation, but to the sky radiant temperature measured by the IR thermometer. Calibration for sky radiant emittance was improved by using the difference between sky radiant temperature and air temperature.When the surface temperature measured by the infrared thermometer is plotted against the surface temperature measured by thermocouple, the sky radiant emittance error is obtained from the Y intercept. Additionally, the difference between true temperature and output of the IR thermometer for a reference plate was compared to that obtained for vegetation, and the RMS obtained was

  19. Inverse optimal design of the radiant heating in materials processing and manufacturing

    Science.gov (United States)

    Fedorov, A. G.; Lee, K. H.; Viskanta, R.

    1998-12-01

    Combined convective, conductive, and radiative heat transfer is analyzed during heating of a continuously moving load in the industrial radiant oven. A transient, quasi-three-dimensional model of heat transfer between a continuous load of parts moving inside an oven on a conveyor belt at a constant speed and an array of radiant heaters/burners placed inside the furnace enclosure is developed. The model accounts for radiative exchange between the heaters and the load, heat conduction in the load, and convective heat transfer between the moving load and oven environment. The thermal model developed has been used to construct a general framework for an inverse optimal design of an industrial oven as an example. In particular, the procedure based on the Levenberg-Marquardt nonlinear least squares optimization algorithm has been developed to obtain the optimal temperatures of the heaters/burners that need to be specified to achieve a prescribed temperature distribution of the surface of a load. The results of calculations for several sample cases are reported to illustrate the capabilities of the procedure developed for the optimal inverse design of an industrial radiant oven.

  20. Socioeconomic determinants of exposure to alcohol outlets.

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R

    2015-05-01

    Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world.

  1. Off-premise alcohol outlet characteristics and violence.

    Science.gov (United States)

    Snowden, Aleksandra J; Pridemore, William Alex

    2014-07-01

    There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.

  2. Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System

    Energy Technology Data Exchange (ETDEWEB)

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F., Jr.; Litvack, F.

    1998-01-16

    RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Champion{trademark} over-the-wire, and TNT{trademark} rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors.

  3. 14 CFR 25.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 25.977 Section 25.977... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  4. 14 CFR 29.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 29.977 Section 29.977... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.977 Fuel tank outlet. (a) There must be a fuel strainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  5. 14 CFR 27.977 - Fuel tank outlet.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel tank outlet. 27.977 Section 27.977... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.977 Fuel tank outlet. (a) There must be a fuel stainer for the fuel tank outlet or for the booster pump. This strainer must— (1) For...

  6. Radiant zone heated particulate filter

    Science.gov (United States)

    Gonze, Eugene V [Pinckney, MI

    2011-12-27

    A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

  7. Socioeconomic Determinants of Exposure to Alcohol Outlets

    Science.gov (United States)

    Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.

    2015-01-01

    Objective: Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Method: Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Results: Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. Conclusions: These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world. PMID:25978830

  8. 16 CFR Figure 4 to Subpart A of... - Flooring Radiant Panel Tester Schematic Low Flux End, Elevation

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Flooring Radiant Panel Tester Schematic Low Flux End, Elevation 4 Figure 4 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY... Standard Pt. 1209, Subpt. A, Fig. 4 Figure 4 to Subpart A of Part 1209—Flooring Radiant Panel Tester...

  9. Applicability of meteor radiant determination methods depending on orbit type. I. High-eccentric orbits

    Science.gov (United States)

    Svoren, J.; Neslusan, L.; Porubcan, V.

    1993-07-01

    It is evident that there is no uniform method of calculating meteor radiants which would yield reliable results for all types of cometary orbits. In the present paper an analysis of this problem is presented, together with recommended methods for various types of orbits. Some additional methods resulting from mathematical modelling are presented and discussed together with Porter's, Steel-Baggaley's and Hasegawa's methods. In order to be able to compare how suitable the application of the individual radiant determination methods is, it is necessary to determine the accuracy with which they approximate real meteor orbits. To verify the accuracy with which the orbit of a meteoroid with at least one node at 1 AU fits the original orbit of the parent body, we applied the Southworth-Hawkins D-criterion (Southworth, R.B., Hawkins, G.S.: 1963, Smithson. Contr. Astrophys 7, 261). D0.2 the fit is rather poor and the change of orbit unrealistic. The optimal methods with the smallest values of D for given types of orbits are shown in two series of six plots. The new method of rotation around the line of apsides we propose is very appropriate in the region of small inclinations. There is no doubt that Hasegawa's omega-adjustment method (Hasegawa, I.: 1990, Publ. Astron. Soc. Japan 42, 175) has the widest application. A comparison of the theoretical radiants with the observed radiants of seven known meteor showers is also presented.

  10. General Relativistic Radiant Shock Waves in the Post-Quasistatic Approximation

    Energy Technology Data Exchange (ETDEWEB)

    H, Jorge A Rueda [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Nunez, L A [Centro de Fisica Fundamental, Universidad de Los Andes, Merida 5101, Venezuela Centro Nacional de Calculo Cientifico, Universidad de Los Andes, CeCalCULA, Corporacion Parque Tecnologico de Merida, Merida 5101, Venezuela (Venezuela)

    2007-05-15

    An evolution of radiant shock wave front is considered in the framework of a recently presented method to study self-gravitating relativistic spheres, whose rationale becomes intelligible and finds full justification within the context of a suitable definition of the post-quasistatic approximation. The spherical matter configuration is divided into two regions by the shock and each side of the interface having a different equation of state and anisotropic phase. In order to simulate dissipation effects due to the transfer of photons and/or neutrinos within the matter configuration, we introduce the flux factor, the variable Eddington factor and a closure relation between them. As we expected the strong of the shock increases the speed of the fluid to relativistic ones and for some critical values is larger than light speed. In addition, we find that energy conditions are very sensible to the anisotropy, specially the strong energy condition. As a special feature of the model, we find that the contribution of the matter and radiation to the radial pressure are the same order of magnitude as in the mant as in the core, moreover, in the core radiation pressure is larger than matter pressure.

  11. General Relativistic Radiant Shock Waves in the Post-Quasistatic Approximation

    International Nuclear Information System (INIS)

    H, Jorge A Rueda; Nunez, L A

    2007-01-01

    An evolution of radiant shock wave front is considered in the framework of a recently presented method to study self-gravitating relativistic spheres, whose rationale becomes intelligible and finds full justification within the context of a suitable definition of the post-quasistatic approximation. The spherical matter configuration is divided into two regions by the shock and each side of the interface having a different equation of state and anisotropic phase. In order to simulate dissipation effects due to the transfer of photons and/or neutrinos within the matter configuration, we introduce the flux factor, the variable Eddington factor and a closure relation between them. As we expected the strong of the shock increases the speed of the fluid to relativistic ones and for some critical values is larger than light speed. In addition, we find that energy conditions are very sensible to the anisotropy, specially the strong energy condition. As a special feature of the model, we find that the contribution of the matter and radiation to the radial pressure are the same order of magnitude as in the mant as in the core, moreover, in the core radiation pressure is larger than matter pressure

  12. Double-outlet right ventricle revisited.

    Science.gov (United States)

    Ebadi, Ameneh; Spicer, Diane E; Backer, Carl L; Fricker, F Jay; Anderson, Robert H

    2017-08-01

    Double-outlet right ventricle is a form of ventriculoarterial connection. The definition formulated by the International Society for Nomenclature of Paediatric and Congenital Heart Disease is based on hearts with both arterial trunks supported in their greater part by a morphologically right ventricle. Bilateral infundibula and ventricular septal defects are highly debated criteria. This study examines the anatomic controversies surrounding double-outlet right ventricle. We show that hearts with double-outlet right ventricle can have atrioventricular-to-arterial valvular continuity. We emphasize the difference between the interventricular communication and the zone of deficient ventricular septation. The hearts examined were from the University of Florida in Gainesville; Johns Hopkins All Children's Hospital, St Petersburg, Fla; and Lurie Children's Hospital, Chicago, Ill. Each specimen had at least 75% of both arterial roots supported by the morphologically right ventricle, with a total of 100 hearts examined. The morphologic method was used to assess anatomic features, including arterial-atrioventricular valvular continuity, subarterial infundibular musculature, and the location of the hole between the ventricles. Most hearts had fibrous continuity between one of the arterial valves and an atrioventricular valve, with bilateral infundibula in 23%, and intact ventricular septum in 5%. Bilateral infundibula are not a defining feature of double-outlet right ventricle, representing only 23% of the specimens in our sample. The interventricular communication can have a posteroinferior muscular rim or extend to become perimembranous (58%). Double-outlet right ventricle can exist with an intact ventricular septum. Copyright © 2017 The American Association for Thoracic Surgery. All rights reserved.

  13. Intelligent electrical outlet for collective load control

    Science.gov (United States)

    Lentine, Anthony L.; Ford, Justin R.; Spires, Shannon V.; Goldsmith, Steven Y.

    2015-10-27

    Various technologies described herein pertain to an electrical outlet that autonomously manages loads in a microgrid. The electrical outlet can provide autonomous load control in response to variations in electrical power generation supply in the microgrid. The electrical outlet includes a receptacle, a sensor operably coupled to the receptacle, and an actuator configured to selectively actuate the receptacle. The sensor measures electrical parameters at the receptacle. Further, a processor autonomously controls the actuator based at least in part on the electrical parameters measured at the receptacle, electrical parameters from one or more disparate electrical outlets in the microgrid, and a supply of generated electric power in the microgrid at a given time.

  14. Patterning of neighbourhood food outlets and longitudinal associations with children's eating behaviours.

    Science.gov (United States)

    Timperio, Anna; Crawford, David; Leech, Rebecca M; Lamb, Karen E; Ball, Kylie

    2018-06-01

    This study examined cross-sectional and prospective associations between typologies of neighbourhood food environment and dietary patterns among 10-12 year-old children. Baseline data were collected in 2003 and follow-up data in 2006 from children in Melbourne or Geelong. Parents completed a food frequency questionnaire at both time points. 'Healthful' and 'energy-dense' dietary pattern scores were computed. A Geographic Information System was used to determine the presence or absence of food outlets (cafés/restaurant; fast food; supermarkets/grocery stores; convenience store; greengrocer; and butcher, seafood or poultry retailer) within an 800 m road network buffer of home. Three typologies were identified: 1-variety of food outlets, including those selling core/fresh foods (n = 96); 2-café/restaurant and convenience (n = 160); 3-few types of outlets (n = 208). Latent class analysis was used to identify underlying unobservable typologies of neighbourhood food outlet availability. Linear mixed models were fitted to determine cross-sectional (n = 439) and longitudinal (n = 173) associations between the three identified neighbourhood typologies and each (log-transformed) dietary pattern, accounting for clustering within families and schools. There was little evidence of cross-sectional associations. The longitudinal analyses showed that compared to those with a variety of food outlets, those with few types had 25% lower scores for the healthful dietary pattern (p < 0.05) three years later. For optimal dietary patterns, availability of a variety of food outlets close to home, particularly those where core/fresh foods are available, may be important. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. EXPERIMENTAL INVESTIGATION OF THE CONVECTIVE HEAT TRANSFER IN A SPIRALLY COILED CORRUGATED TUBE WITH RADIANT HEATING

    Directory of Open Access Journals (Sweden)

    Milan Đorđević

    2017-12-01

    Full Text Available The Archimedean spiral coil made of a transversely corrugated tube was exposed to radiant heating in order to represent a heat absorber of the parabolic dish solar concentrator. The main advantage of the considered innovative design solution is a coupling effect of the two passive methods for heat transfer enhancement - coiling of the flow channel and changes in surface roughness. The curvature ratio of the spiral coil varies from 0.029 to 0.234, while water and a mixture of propylene glycol and water are used as heat transfer fluids. The unique focus of this study is on specific boundary conditions since the heat flux upon the tube external surfaces varies not only in the circumferential direction, but in the axial direction as well. Instrumentation of the laboratory model of the heat absorber mounted in the radiation field includes measurement of inlet fluid flow rate, pressure drop, inlet and outlet fluid temperature and 35 type K thermocouples welded to the coil surface. A thermal analysis of the experimentally obtained data implies taking into consideration the externally applied radiation field, convective and radiative heat losses, conduction through the tube wall and convection to the internal fluid. The experimental results have shown significant enhancement of the heat transfer rate compared to spirally coiled smooth tubes, up to 240% in the turbulent flow regime.

  16. MRI of thoracic outlet syndrome in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Batmanabane, Vaishnavi; Muthusami, Prakash; Towbin, Alexander J.; Borschel, Gregory H.

    2017-01-01

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  17. MRI of thoracic outlet syndrome in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Batmanabane, Vaishnavi [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); Muthusami, Prakash [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto, ON (Canada); The Hospital for Sick Children, Division of Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology and Medical Imaging, Cincinnati, OH (United States); Borschel, Gregory H. [The Hospital for Sick Children and University of Toronto, Division of Plastic Surgery, Department of Pediatric Surgery, Toronto, ON (Canada)

    2017-09-15

    Thoracic outlet syndrome is caused by compression of the neurovascular bundle as it passes from the upper thorax to the axilla. The neurovascular bundle can be compressed by bony structures such as the first rib, cervical ribs or bone tubercles, or from soft-tissue abnormalities like a fibrous band, muscle hypertrophy or space-occupying lesion. Thoracic outlet syndrome commonly affects young adults but can be seen in the pediatric age group, especially in older children. Diagnosis is based on a holistic approach encompassing clinical features, physical examination findings including those triggered by various maneuvers, electromyography, nerve conduction studies and imaging. Imaging is performed to confirm the diagnosis, exclude mimics and classify thoracic outlet syndrome into neurogenic, arterial, venous or mixed causes. MRI and MR angiography are useful in this process. A complete MRI examination for suspected thoracic outlet syndrome should include the assessment of anatomy and any abnormalities using routine sequences, vessel assessment with the arms in adduction by MR angiography and assessment of dynamic compression of vessels with abduction of the arms. The purpose of this paper is to describe the anatomy of the thoracic outlet, causes of thoracic outlet syndrome, the MR imaging techniques used in its diagnosis and the principles of image interpretation. (orig.)

  18. Alcohol Outlets and Violent Crime in Washington D.C.

    Directory of Open Access Journals (Sweden)

    Pan, William K

    2010-08-01

    Full Text Available Objective: Alcohol is more likely than any other drug to be involved in substance-related violence. In 2000 violence-related and self-directed injuries accounted for an estimated $37 billion and $33 billion in productivity losses and medical treatment, respectively. A review of emergency department data revealed violence and clinically identified trauma-related injuries have the strongest correlation among alcohol-dependent injuries. At the environmental level there is a relationship between alcohol outlet density and violent crime. A limited number of studies have examined the relationship between alcohol outlet type and the components of violent crime. The aim of this study is to examine the relationship between the aggregate components of violent crime and alcohol outlet density by type of outlet.Methods: For this study we used Washington, D.C. census tract data from the 2000 census to examine neighborhood characteristics. Alcohol outlet, violent crime, and population-level data for Washington, D.C. were drawn from various official yet publicly available sources. We developed an analytic database to examine the relationship between alcohol outlet category and four types of violent crime. After estimating spatial correlation and determining spatial dependence, we used a negative binomial regression analysis to assess the alcohol availability-violent crime association, while controlling for structural correlates of violence.Results: Independent of alternative structural correlates of violent crime, including the prevalence of weapons and illicit drugs, community-level alcohol outlet density is significantly associated with assaultive violence. Outlets were significantly related to robbery, assault, and sexual offenses. In addition, the relationship among on-premise and off-premise outlets varied across violent crime categories.Conclusion: In Washington, D.C., alcohol outlet density is significantly associated with the violent crimes. The

  19. Towards a uniform specification of light therapy devices for the treatment of affective disorders and use for non-image forming effects: Radiant flux.

    Science.gov (United States)

    Aarts, M P J; Rosemann, A L P

    2018-08-01

    For treating affective disorders like SAD, light therapy is used although the underlying mechanism explaining this success remains unclear. To accelerate the research on defining the light characteristics responsible for inducing a specific effect a uniform manner for specifying the irradiance at the eye should be defined. This allows a genuine comparison between light-affect studies. An important factor impacting the irradiance at the eye are the radiant characteristics of the used light therapy device. In this study the radiant fluxes of five different light therapy devices were measured. The values were weighted against the spectral sensitivity of the five photopigments present in the human eye. A measurement was taken every five minutes to control for a potential stabilizing effect. The results show that all five devices show large differences in radiant flux. The devices equipped with blue LED lights have a much lower spectral radiant flux than the devices equipped with a fluorescent light source or a white LED. The devices with fluorescent lamps needed 30 min to stabilize to a constant radiant flux. In this study only five devices were measured. Radiant flux is just the first step to identify uniform specifications for light therapy devices. It is recommended to provide all five α-opic radiant fluxes. Preferably, the devices should come with a spectral power distribution of the radiant flux. For the devices equipped with a fluorescent lamp it is recommended to provide information on the stabilization time. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. 49 CFR 178.345-11 - Tank outlets.

    Science.gov (United States)

    2010-10-01

    ... unloading of lading, as distinguished from outlets such as manhole covers, vents, vapor recovery devices... away from the loading/unloading outlet. The actuating mechanism must be corrosion-resistant and...

  1. Hydrologic Outlets of the Greenland Ice Sheet

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  2. Reducing heat loss from the energy absorber of a solar collector

    Science.gov (United States)

    Chao, Bei Tse; Rabl, Ari

    1976-01-01

    A device is provided for reducing convective heat loss in a cylindrical radiant energy collector. It includes a curved reflective wall in the shape of the arc of a circle positioned on the opposite side of the exit aperture from the reflective side walls of the collector. Radiant energy exiting the exit aperture is directed by the curved wall onto an energy absorber such that the portion of the absorber upon which the energy is directed faces downward to reduce convective heat loss from the absorber.

  3. Theoretical Analysis of Interferometer Wave Front Tilt and Fringe Radiant Flux on a Rectangular Photodetector

    Directory of Open Access Journals (Sweden)

    Franz Konstantin Fuss

    2013-09-01

    Full Text Available This paper is a theoretical analysis of mirror tilt in a Michelson interferometer and its effect on the radiant flux over the active area of a rectangular photodetector or image sensor pixel. It is relevant to sensor applications using homodyne interferometry where these opto-electronic devices are employed for partial fringe counting. Formulas are derived for radiant flux across the detector for variable location within the fringe pattern and with varying wave front angle. The results indicate that the flux is a damped sine function of the wave front angle, with a decay constant of the ratio of wavelength to detector width. The modulation amplitude of the dynamic fringe pattern reduces to zero at wave front angles that are an integer multiple of this ratio and the results show that the polarity of the radiant flux changes exclusively at these multiples. Varying tilt angle causes radiant flux oscillations under an envelope curve, the frequency of which is dependent on the location of the detector with the fringe pattern. It is also shown that a fringe count of zero can be obtained for specific photodetector locations and wave front angles where the combined effect of fringe contraction and fringe tilt can have equal and opposite effects. Fringe tilt as a result of a wave front angle of 0.05° can introduce a phase measurement difference of 16° between a photodetector/pixel located 20 mm and one located 100 mm from the optical origin.

  4. Mapping temperature and radiant geothermal heat flux anomalies in the Yellowstone geothermal system using ASTER thermal infrared data

    Science.gov (United States)

    Vaughan, R. Greg; Lowenstern, Jacob B.; Keszthelyi, Laszlo P.; Jaworowski, Cheryl; Heasler, Henry

    2012-01-01

    The purpose of this work was to use satellite-based thermal infrared (TIR) remote sensing data to measure, map, and monitor geothermal activity within the Yellowstone geothermal area to help meet the missions of both the U.S. Geological Survey Yellowstone Volcano Observatory and the Yellowstone National Park Geology Program. Specifically, the goals were to: 1) address the challenges of remotely characterizing the spatially and temporally dynamic thermal features in Yellowstone by using nighttime TIR data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and 2) estimate the temperature, geothermal radiant emittance, and radiant geothermal heat flux (GHF) for Yellowstone’s thermal areas (both Park wide and for individual thermal areas). ASTER TIR data (90-m pixels) acquired at night during January and February, 2010, were used to estimate surface temperature, radiant emittance, and radiant GHF from all of Yellowstone’s thermal features, produce thermal anomaly maps, and update field-based maps of thermal areas. A background subtraction technique was used to isolate the geothermal component of TIR radiance from thermal radiance due to insolation. A lower limit for the Yellowstone’s total radiant GHF was established at ~2.0 GW, which is ~30-45% of the heat flux estimated through geochemical (Cl-flux) methods. Additionally, about 5 km2 was added to the geodatabase of mapped thermal areas. This work provides a framework for future satellite-based thermal monitoring at Yellowstone as well as exploration of other volcanic / geothermal systems on a global scale.

  5. The geography of Fast Food outlets: a review.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberly L; Cade, Janet; Clarke, Graham P

    2010-05-01

    The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  6. The Geography of Fast Food Outlets: A Review

    Directory of Open Access Journals (Sweden)

    Lorna K. Fraser

    2010-05-01

    Full Text Available The availability of food high in fat, salt and sugar through Fast Food (FF or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.

  7. Clouds and Earth Radiant Energy System (CERES), a Review: Past, Present and Future

    Science.gov (United States)

    Smith, G. L.; Priestley, K. J.; Loeb, N. G.; Wielicki, B. A.; Charlock, T. P.; Minnis, P.; Doelling, D. R.; Rutan, D. A.

    2011-01-01

    The Clouds and Earth Radiant Energy System (CERES) project s objectives are to measure the reflected solar radiance (shortwave) and Earth-emitted (longwave) radiances and from these measurements to compute the shortwave and longwave radiation fluxes at the top of the atmosphere (TOA) and the surface and radiation divergence within the atmosphere. The fluxes at TOA are to be retrieved to an accuracy of 2%. Improved bidirectional reflectance distribution functions (BRDFs) have been developed to compute the fluxes at TOA from the measured radiances with errors reduced from ERBE by a factor of two or more. Instruments aboard the Terra and Aqua spacecraft provide sampling at four local times. In order to further reduce temporal sampling errors, data are used from the geostationary meteorological satellites to account for changes of scenes between observations by the CERES radiometers. A validation protocol including in-flight calibrations and comparisons of measurements has reduced the instrument errors to less than 1%. The data are processed through three editions. The first edition provides a timely flow of data to investigators and the third edition provides data products as accurate as possible with resources available. A suite of cloud properties retrieved from the MODerate-resolution Imaging Spectroradiometer (MODIS) by the CERES team is used to identify the cloud properties for each pixel in order to select the BRDF for each pixel so as to compute radiation fluxes from radiances. Also, the cloud information is used to compute radiation at the surface and through the atmosphere and to facilitate study of the relationship between clouds and the radiation budget. The data products from CERES include, in addition to the reflected solar radiation and Earth emitted radiation fluxes at TOA, the upward and downward shortwave and longwave radiation fluxes at the surface and at various levels in the atmosphere. Also at the surface the photosynthetically active radiation

  8. Radiant recuperator modelling and design

    Directory of Open Access Journals (Sweden)

    Knežević Suzana D.

    2017-01-01

    Full Text Available Recuperators are frequently used in glass production and metallurgical processes to preheat combustion air by heat exchange with high temperature flue gases. Mass and energy balances of a 15 m high, concurrent radiant recuperator used in a glass fiber production process are given. The balances are used: for validation of a cell modeling method that predicts the performance of different recuperator designs, and for finding a simple solution to improve the existing recuperator. Three possible solutions are analyzed: to use the existing recuperator as a countercurrent one, to add an extra cylinder over the existing construction, and to make a system that consists of a central pipe and two concentric annular ducts. In the latter, two air streams flow in opposite directions, whereas air in the inner annular passage flows concurrently or countercurrently to flue gases. Compared with the concurrent recuperator, the countercurrent has only one drawback: the interface temperature is higher at the bottom. The advantages are: lower interface temperature at the top where the material is under maximal load, higher efficiency, and smaller pressure drop. Both concurrent and countercurrent double pipe-in-pipe systems are only slightly more efficient than pure concurrent and countercurrent recuperators, respectively. Their advantages are smaller interface temperatures whereas the disadvantages are their costs and pressure drops. To implement these solutions, the average velocities should be: for flue gas around 5 m/s, for air in the first passage less than 2 m/s, and for air in the second passage more than 25 m/s. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. EE 33027

  9. Phase-Change Thermal Energy Storage

    Science.gov (United States)

    1989-11-01

    The goal of this program is to advance the engineering and scientific understanding of solar thermal technology and to establish the technology base from which private industry can develop solar thermal power production options for introduction into the competitive energy market. Solar thermal technology concentrates the solar flux using tracking mirrors or lenses onto a receiver where the solar energy is absorbed as heat and converted into electricity or incorporated into products as process heat. The two primary solar thermal technologies, central receivers and distributed receivers, employ various point and line-focus optics to concentrate sunlight. Current central receiver systems use fields of heliostats (two-axes tracking mirrors) to focus the sun's radiant energy onto a single, tower-mounted receiver. Point focus concentrators up to 17 meters in diameter track the sun in two axes and use parabolic dish mirrors or Fresnel lenses to focus radiant energy onto a receiver. Troughs and bowls are line-focus tracking reflectors that concentrate sunlight onto receiver tubes along their focal lines. Concentrating collector modules can be used alone or in a multimodule system. The concentrated radiant energy absorbed by the solar thermal receiver is transported to the conversion process by a circulating working fluid. Receiver temperatures range from 100 C in low-temperature troughs to over 1500 C in dish and central receiver systems.

  10. Analysis of directional radiative behavior and heating efficiency for a gas-fired radiant burner

    International Nuclear Information System (INIS)

    Li, B.X.; Lu, Y.P.; Liu, L.H.; Kudo, K.; Tan, H.P.

    2005-01-01

    For the purpose of energy conservation and uniform heating of object surface, a gas-fired porous radiant burner with a bundle of reflecting tubes is developed. A physical model is developed to simulate the directional radiative behavior of this heating device, in which the Monte Carlo method based on the concept of radiation distribution factor is used to compute the directional radiative behavior. The effects of relating parameters on the directional behavior of radiative heating and the heating efficiency are analyzed. With the increase of the length-to-radius ratio of tube, the radiation heating efficiency decreases, but the radiation energy incident on the object surface is more collimated. The radiation heating efficiency increases with the specular reflectivity. With the increase in length of tube segment with specular reflective surface, the radiation heating efficiency increases, but the extent of concentration and collimation of radiative energy decreases. For real design of the heating device, some trade-offs are needed to balance the radiation heating efficiency and the uniformity of radiative heating of object surface

  11. Radiant non-catalytic recuperative reformer

    Energy Technology Data Exchange (ETDEWEB)

    Khinkis, Mark J.; Kozlov, Aleksandr P.

    2017-10-31

    A radiant, non-catalytic recuperative reformer has a flue gas flow path for conducting hot exhaust gas from a thermal process and a reforming mixture flow path for conducting a reforming mixture. At least a portion of the reforming mixture flow path is positioned adjacent to the flue gas flow path to permit heat transfer from the hot exhaust gas to the reforming mixture. The reforming mixture flow path contains substantially no material commonly used as a catalyst for reforming hydrocarbon fuel (e.g., nickel oxide, platinum group elements or rhenium), but instead the reforming mixture is reformed into a higher calorific fuel via reactions due to the heat transfer and residence time. In a preferred embodiment, a portion of the reforming mixture flow path is positioned outside of flue gas flow path for a relatively large residence time.

  12. Tobacco Retail Outlets and Vulnerable Populations in Ontario, Canada

    Directory of Open Access Journals (Sweden)

    Michael O. Chaiton

    2013-12-01

    Full Text Available Interest has been increasing in regulating the location and number of tobacco vendors as part of a comprehensive tobacco control program. The objective of this paper is to examine the distribution of tobacco outlets in a large jurisdiction, to assess: (1 whether tobacco outlets are more likely to be located in vulnerable areas; and (2 what proportion of tobacco outlets are located close to schools. Retail locations across the Province of Ontario from Ministry of Health Promotion data were linked to 2006 Census data at the neighbourhood level. There was one tobacco retail outlet for every 1,000 people over age 15 in Ontario. Density of outlets varied by public health unit, and was associated with the number of smokers. Tobacco outlets were more likely to be located in areas that had high neighbourhood deprivation, in both rural and urban areas. Outlets were less likely to be located in areas with high immigrant populations in urban areas, with the reverse being true for rural areas. Overall, 65% of tobacco retailers were located within 500 m of a school. The sale of tobacco products is ubiquitous, however, neighbourhoods with lower socio-economic status are more likely to have easier availability of tobacco products and most retailers are located within walking distance of a school. The results suggest the importance of policies to regulate the location of tobacco retail outlets.

  13. Process evaluation of the RaDIANT community study: a dialysis facility-level intervention to increase referral for kidney transplantation.

    Science.gov (United States)

    Hamoda, Reem E; Gander, Jennifer C; McPherson, Laura J; Arriola, Kimberly J; Cobb, Loren; Pastan, Stephen O; Plantinga, Laura; Browne, Teri; Hartmann, Erica; Mulloy, Laura; Zayas, Carlos; Krisher, Jenna; Patzer, Rachel E

    2018-01-15

    The Reducing Disparities in Access to kidNey Transplantation Community Study (RaDIANT) was an End-Stage Renal Disease (ESRD) Network 6-developed, dialysis facility-level randomized trial testing the effectiveness of a 1-year multicomponent education and quality improvement intervention in increasing referral for kidney transplant evaluation among selected Georgia dialysis facilities. To assess implementation of the RaDIANT intervention, we conducted a process evaluation at the conclusion of the intervention period (January-December 2014). We administered a 20-item survey to the staff involved with transplant education in 67 dialysis facilities randomized to participate in intervention activities. Survey items assessed facility participation in the intervention (fidelity and reach), helpfulness and willingness to continue intervention activities (sustainability), suggestions for improving intervention components (sustainability), and factors that may have influenced participation and study outcomes (context). We defined high fidelity to the intervention as completing 11 or more activities, and high participation in an activity as having at least 75% participation across intervention facilities. Staff from 65 of the 67 dialysis facilities completed the questionnaire, and more than half (50.8%) reported high adherence (fidelity) to RaDIANT intervention requirements. Nearly two-thirds (63.1%) of facilities reported that RaDIANT intervention activities were helpful or very helpful, with 90.8% of facilities willing to continue at least one intervention component beyond the study period. Intervention components with high participation emphasized staff and patient-level education, including in-service staff orientations, patient and family education programs, and patient educational materials. Suggested improvements for intervention activities emphasized addressing financial barriers to transplantation, with financial education materials perceived as most helpful among RaDIANT

  14. A METHOD FOR EVALUATION OF NON-UNIFORM RADIANT-CONVECTIVE LOAD ON HUMAN BODY DURING MENTAL WORK

    Directory of Open Access Journals (Sweden)

    Lenka Prokšová Zuská

    2017-10-01

    Full Text Available The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.

  15. Dynamic behavior of radiant cooling system based on capillary tubes in walls made of high performance concrete

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Svendsen, Svend

    2015-01-01

    elements made of high performance concrete. The influence of the radiant cooling system on the indoor climate of the test room in terms of the air, surface and operative temperatures and velocities was investigated.The results show that the temperature of the room air can be kept in a comfortable range...... using cooling water for the radiant cooling system with a temperature only about 4K lower than the temperature of the room air. The relatively high speed reaction of the designed system is a result of the slim construction of the sandwich wall elements made of high performance concrete. (C) 2015...... the small amount of fresh air required by standards to provide a healthy indoor environment.This paper reports on experimental analyses evaluating the dynamic behavior of a test room equipped with a radiant cooling system composed of plastic capillary tubes integrated into the inner layer of sandwich wall...

  16. Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2010-01-01

    The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems...... is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly...... calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling...

  17. Approach to the HTGR core outlet temperature measurements in the United States

    International Nuclear Information System (INIS)

    Franklin, R.; Rodriguez, C.

    1982-06-01

    The High Temperature Gas-Cooled Reactor (HTGR) constructed at Fort St. Vrain Colorado (330 MWe) used Geminol thermocouples to measure the primary coolant temperature at the core outlet. The primary coolant (helium) is heated by the graphite core to temperatures in the range of 700 deg. to 750 deg. C. The combination of the high temperature, high flow rate and radiation at the core outlet area makes it difficult to obtain accurate temperature measurements. The Geminol thermocouples installed in the Fort St. Vrain reactor have provided accurate data for several years of power operation without any failures. The indicated temperature of the core outlet thermocouples agrees with a ''traversing'' thermocouple measurement to within +-2 deg. C. The Geminol thermocouple wire was provided by the Driver-Harris Company and is similar to the chromel versus alumel thermocouple. Geminol wire is no longer distributed and on future designs, chromel versus alumel wire will be used. The next large HTGR design, which is being performed with funding support from the United States Department of Energy, will incorporate replaceable thermocouples. The thermocouples used in the Fort St. Vrain reactor were permanently installed and large in diameter (6.35 mm) to insure good reliability. The replaceable thermocouples to be used in the next large reactor will be smaller in diameter (3.18 mm). These replaceable thermocouples will be inserted into the core outlet area through long curved guide tubes that are permanently installed. These guide tubes are as long as 18 meters and must be curved to reach the core outlet regions. Tests were conducted to prove that the thermocouples could be inserted and removed through the long curved guide tubes. (author)

  18. Energy efficient heating and ventilation of large halls

    CERN Document Server

    Hojer, Ondrej; Kabele, Karel; Kotrbaty, Miroslav; Sommer, Klaus; Petras, Dusan

    2011-01-01

    This guidebook is focused on modern methods for design, control and operation of energy efficient heating systems in large spaces and industrial halls. The book deals with thermal comfort, light and dark gas radiant heaters, panel radiant heating, floor heating and industrial air heating systems. Various heating systems are illustrated with case studies. Design principles, methods and modeling tools are presented for various systems.

  19. A temporal analysis of the spatial clustering of food outlets around schools in Christchurch, New Zealand, 1966 to 2006.

    Science.gov (United States)

    Day, Peter L; Pearce, Jamie R; Pearson, Amber L

    2015-01-01

    To explore changes in urban food environments near schools, as potential contributors to the rising prevalence of overweight and obesity among children. Addresses of food premises and schools in 1966, 1976, 1986, 1996 and 2006 were geo-coded. For each year, the number and proportion of outlets by category (supermarket/grocery; convenience; fast-food outlet) within 800 m of schools were calculated. The degree of spatial clustering of outlets was assessed using a bivariate K-function analysis. Food outlet categories, school level and school social deprivation quintiles were compared. Christchurch, New Zealand. All schools and food outlets at 10-year snapshots from 1966 to 2006. Between 1966 and 2006, the median number of supermarkets/grocery stores within 800 m of schools decreased from 5 to 1, convenience stores decreased from 2 to 1, and fast-food outlets increased from 1 to 4. The ratio of fast-food outlets to total outlets increased from 0·10 to 0·67. The clustering of fast-food outlets was greatest within 800 m of schools and around the most socially deprived schools. Over the 40-year study period, school food environments in Christchurch can be characterized by increased densities of fast-food outlets within walking distance of schools, especially around the most deprived schools. Since the 1960s, there have been substantial changes to the food environments around schools which may increasingly facilitate away-from-home food consumption for children and provide easily accessible, cheap energy-dense foods, a recognized contributor to the rise in prevalence of overweight and obesity among young people.

  20. Morteros acumuladores con parafinas microencapsuladas para el aprovechamiento de la energía solar en suelos radiantes

    OpenAIRE

    Zetola Vargas, Vicente Andrés

    2013-01-01

    Esta Tesis plantea la pregunta de si el uso de morteros con parafinas microencapsuladas combinado con colectores solares térmicos puede reducir el consumo de energías convencionales, en un sistema tradicional de suelo radiante. Se pretende contribuir al conocimiento acerca del efecto que produce en el edificio, el calor latente acumulado en suelos radiantes, utilizando morteros de cemento Portland con material de cambio de fase (PCM), en conjunto con la energía solar. Para cumplir con este pr...

  1. Analysis of the Sales Promotion in Choice Retail Outlet

    OpenAIRE

    HUMPOLCOVÁ, Michaela

    2010-01-01

    My bachelor thesis is aimed at sales promotion in a retail outlet. The main aim of this thesis is evaluate the current state of sales promotion in a selected retail outlet and based on the analysis of the current state of sales promotion in the outlet to try to propose some measures of improve.

  2. Use of local convective and radiant cooling at warm environment: effect on thermal comfort and perceived air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Duszyk, Marcin; Krejcirikova, Barbora

    2012-01-01

    The effect of four local cooling devices (convective, radiant and combined) on thermal comfort and perceived air quality reported by 24 subjects at 28 ˚C and 50% RH was studied. The devices studied were: (1) desk cooling fan, (2) personalized ventilation providing clean air, (3) two radiant panels...... and (4) two radiant panels with one panel equipped with small fans. A reference condition without cooling was tested as well. The response of the subjects to the exposed conditions was collected by computerized questionnaires. The cooling devices significantly (pthermal comfort...... compared to without cooling. The acceptability of the thermal environment was similar for all cooling devices. The acceptability of air movement and PAQ increased when the local cooling methods were used. The best results were achieved with personalized ventilation and cooling fan. The improvement in PAQ...

  3. Availability of limited service food outlets surrounding schools in British Columbia.

    Science.gov (United States)

    Black, Jennifer L; Day, Meghan

    2012-06-05

    The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.

  4. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study.

    Science.gov (United States)

    Burgoine, Thomas; Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J; Monsivais, Pablo

    2016-06-01

    Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. In a population-based cohort of 5958 adults aged 29-62 y in Cambridgeshire, United Kingdom, we used educational attainment-stratified regression models to estimate the food-frequency questionnaire-derived consumption of energy-dense "fast foods" (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m(2)) across geographic information system-derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005-2013 and analyzed in 2015. Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity.

  5. Clean and efficient energy conversion processes (Cecon-project). Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The objectives of the work programme reported are the development and testing of two optimised energy conversion processes, both consisting of a radiant surface gas burner and a ceramic heat exchanger. The first sub-objective of the programme is related to industrial heating, drying and curing processes requireing low and medium heat fluxes. It is estimated that around one tenth of the total EC industrial energy use is associated with such processes. The majority of these processes currently use convection and conduction as the main heat transfer mechanisms and overall energy efficiencies are typically below 25%. For many drying and finishing processes (such as curing powder coatings and drying paints, varnishes, inks, and for the fabrication of paper and textiles), radiant heating can achieve much faster dyring rates and higher energy efficiency than convective heating. In the project new concepts of natural gas fired radiant heating have been investigated which would be much more efficient than the existing processes. One element of the programme was the evelopment of gas burners having enhanced radiant efficiencies. A second concerned the investigation of the safety of gas burners containing significant volumes of mixed gas and air. Finally the new gas burners were tested in combination with the high temperature heat exchanger to create highly efficient radiant heating systems. The second sub-objective concerned the development of a compact low cost heat exchanger capable of achieving high levels of heat recovery (up to 60%) which could be easily installed on industrial processes. This would make heat recovery a practical proposition on processes where existing heat recovery technology is currently not cost effective. The project will have an impact on industrial processes consuming around 80 MTOE of energy per year within EU countries (1 MTOE equals 41.8 PJ). The overall energy saving potential of the project is estimated to be around 22 MTOE which is around 10

  6. Thermal environment in simulated offices with convective and radiant cooling systems under cooling (summer) mode of operation

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Bolashikov, Zhecho Dimitrov; Kostov, Kalin

    2016-01-01

    The thermal environment in a double office room and in a six-person meeting room obtained with chilled beam (CB), chilled beam with radiant panel (CBR), chilled ceiling with ceiling installed mixing ventilation (CCMV) and four desk partition-mounted local radiant cooling panels with mixing...... calculated. Manikin-based equivalent temperature (MBET) was determined by using two thermal manikins to identify the impact of the local thermal conditions generated by the studied systems on occupants' thermal perception. The results revealed that the differences in the thermal conditions achieved...

  7. Thoracic outlet syndrome: Case report

    International Nuclear Information System (INIS)

    Marquez, Juan Camilo; Acosta, Mauricio Fernando; Uribe Jorge Ricardo

    2009-01-01

    We report a case of vascular thoracic outlet syndrome in a young man, diagnosed with upper limb arteriography, leading to repeated arterio-arterial emboli originating from a post-stenotic subclavian artery aneurysm. It is of our interest due to its low incidence and the small number of cases reported that have been diagnosed by arteriography. The thoracic outlet is the path through which vascular and neural structures goes from the neck to the axilla, and it has three anatomical strictures, that when pronounced, can compress the brachial plexus or subclavian vessels, leading to different symptoms and signs.

  8. A full-scale experimental set-up for assessing the energy performance of radiant wall and active chilled beam for cooling buildings

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    in decreasing the cooling need of the radiant wall compared to the active chilled beam. It has also been observed that the type and repartition of heat load have an influence on the cooling demand. Regarding the comfort level, both terminals met the general requirements, except at high solar heat gains......: overheating has been observed due to the absence of solar shading and the limited cooling capacity of the terminals. No local discomfort has been observed although some segments of the thermal manikin were slightly colder....

  9. Experimental and numerical analysis of air and radiant cooling systems in offices

    DEFF Research Database (Denmark)

    Corgnati, S. P.; Perino, M.; Fracastoro, G. V.

    2009-01-01

    This paper analyses office cooling systems based on all air mixing ventilation systems alone or coupled with radiant ceiling panels. This last solution may be effectively applied to retrofit all air systems that are no longer able to maintain a suitable thermal comfort in the indoor environment, ...

  10. Radiant heat transfers in turbojet engines. Two applications, three levels of modeling; Transferts radiatifs dans les foyers de turboreacteurs. Deux applications, trois niveaux de modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J L; Desaulty, M [SNECMA, Centre de Villaroche, 77 - Moissy-Cramayel (France); Taine, J [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France)

    1997-12-31

    Several applications linked with the dimensioning of turbojet engines require the use of modeling of radiant heat transfers. Two different applications are presented in this study: the modeling of heat transfers in the main combustion chamber, and modeling of the infrared signature of the post-combustion chamber of a military engine. In the first application, two types of radiant heat transfer modeling are presented: a global modeling based on empirical considerations and used in rapid pre-dimensioning methods, and a modeling based on a grey gases concept and combined to a ray shooting type technique allowing the determination of local radiant heat flux values. In the second application, a specific modeling of the radiant heat flux is used in the framework of a ray shooting method. Each model represents a different level of successive approximations of the radiant heat transfer adapted to flow specificities and to the performance requested. (J.S.) 16 refs.

  11. Radiant heat transfers in turbojet engines. Two applications, three levels of modeling; Transferts radiatifs dans les foyers de turboreacteurs. Deux applications, trois niveaux de modelisation

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.L.; Desaulty, M. [SNECMA, Centre de Villaroche, 77 - Moissy-Cramayel (France); Taine, J. [Ecole Centrale de Paris, Laboratoire EM2C. CNRS, 92 - Chatenay-Malabry (France)

    1996-12-31

    Several applications linked with the dimensioning of turbojet engines require the use of modeling of radiant heat transfers. Two different applications are presented in this study: the modeling of heat transfers in the main combustion chamber, and modeling of the infrared signature of the post-combustion chamber of a military engine. In the first application, two types of radiant heat transfer modeling are presented: a global modeling based on empirical considerations and used in rapid pre-dimensioning methods, and a modeling based on a grey gases concept and combined to a ray shooting type technique allowing the determination of local radiant heat flux values. In the second application, a specific modeling of the radiant heat flux is used in the framework of a ray shooting method. Each model represents a different level of successive approximations of the radiant heat transfer adapted to flow specificities and to the performance requested. (J.S.) 16 refs.

  12. Where the Solar system meets the solar neighbourhood: patterns in the distribution of radiants of observed hyperbolic minor bodies

    Science.gov (United States)

    de la Fuente Marcos, Carlos; de la Fuente Marcos, Raúl; Aarseth, Sverre J.

    2018-05-01

    Observed hyperbolic minor bodies might have an interstellar origin, but they can be natives of the Solar system as well. Fly-bys with the known planets or the Sun may result in the hyperbolic ejection of an originally bound minor body; in addition, members of the Oort cloud could be forced to follow inbound hyperbolic paths as a result of secular perturbations induced by the Galactic disc or, less frequently, due to impulsive interactions with passing stars. These four processes must leave distinctive signatures in the distribution of radiants of observed hyperbolic objects, both in terms of coordinates and velocity. Here, we perform a systematic numerical exploration of the past orbital evolution of known hyperbolic minor bodies using a full N-body approach and statistical analyses to study their radiants. Our results confirm the theoretical expectations that strong anisotropies are present in the data. We also identify a statistically significant overdensity of high-speed radiants towards the constellation of Gemini that could be due to the closest and most recent known fly-by of a star to the Solar system, that of the so-called Scholz's star. In addition to and besides 1I/2017 U1 (`Oumuamua), we single out eight candidate interstellar comets based on their radiants' velocities.

  13. Catchment power and the joint distribution of elevation and travel distance to the outlet

    Directory of Open Access Journals (Sweden)

    L. S. Sklar

    2016-10-01

    Full Text Available The delivery of water, sediment, and solutes by catchments is influenced by the distribution of source elevations and their travel distances to the outlet. For example, elevation affects the magnitude and phase of precipitation, as well as the climatic factors that govern rock weathering, which influence the production rate and initial particle size of sediments. Travel distance, in turn, affects the timing of flood peaks at the outlet and the degree of sediment size reduction by wear, which affects particle size distributions at the outlet. The distributions of elevation and travel distance have been studied extensively but separately, as the hypsometric curve and width function. Yet a catchment can be considered as a collection of points, each with paired values of elevation and travel distance. For every point, the ratio of elevation to travel distance defines the mean slope for transport of mass to the outlet. Recognizing that mean slope is proportional to the average rate of loss of potential energy by water and sediment during transport to the outlet, we use the joint distribution of elevation and travel distance to define two new metrics for catchment geometry: "source-area power", and the corresponding catchment-wide integral "catchment power". We explore patterns in source-area and catchment power across three study catchments spanning a range of relief and drainage area. We then develop an empirical algorithm for generating synthetic source-area power distributions, which can be parameterized with data from natural catchments. This new way of quantifying the three-dimensional geometry of catchments can be used to explore the effects of topography on the distribution on fluxes of water, sediment, isotopes, and other landscape products passing through catchment outlets, and may provide a fresh perspective on problems of both practical and theoretical interest.

  14. Solar ultraviolet and the occupational radiant exposure of Queensland school teachers: A comparative study between teaching classifications and behavior patterns.

    Science.gov (United States)

    Downs, Nathan J; Harrison, Simone L; Chavez, Daniel R Garzon; Parisi, Alfio V

    2016-05-01

    Classroom teachers located in Queensland, Australia are exposed to high levels of ambient solar ultraviolet as part of the occupational requirement to provide supervision of children during lunch and break times. We investigated the relationship between periods of outdoor occupational radiant exposure and available ambient solar radiation across different teaching classifications and schools relative to the daily occupational solar ultraviolet radiation (HICNIRP) protection standard of 30J/m(2). Self-reported daily sun exposure habits (n=480) and personal radiant exposures were monitored using calibrated polysulphone dosimeters (n=474) in 57 teaching staff from 6 different schools located in tropical north and southern Queensland. Daily radiant exposure patterns among teaching groups were compared to the ambient UV-Index. Personal sun exposures were stratified among teaching classifications, school location, school ownership (government vs non-government), and type (primary vs secondary). Median daily radiant exposures were 15J/m(2) and 5J/m(2)HICNIRP for schools located in northern and southern Queensland respectively. Of the 474 analyzed dosimeter-days, 23.0% were found to exceed the solar radiation protection standard, with the highest prevalence found among physical education teachers (57.4% dosimeter-days), followed by teacher aides (22.6% dosimeter-days) and classroom teachers (18.1% dosimeter-days). In Queensland, peak outdoor exposure times of teaching staff correspond with periods of extreme UV-Index. The daily occupational HICNIRP radiant exposure standard was exceeded in all schools and in all teaching classifications. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Does neighborhood fast-food outlet exposure amplify inequalities in diet and obesity? A cross-sectional study12

    Science.gov (United States)

    Forouhi, Nita G; Griffin, Simon J; Brage, Søren; Wareham, Nicholas J

    2016-01-01

    Background: Greater exposures to fast-food outlets and lower levels of education are independently associated with less healthy diets and obesity. Little is known about the interplay between these environmental and individual factors. Objective: The purpose of this study was to test whether observed differences in fast-food consumption and obesity by fast-food outlet exposure are moderated by educational attainment. Design: In a population-based cohort of 5958 adults aged 29–62 y in Cambridgeshire, United Kingdom, we used educational attainment–stratified regression models to estimate the food-frequency questionnaire–derived consumption of energy-dense “fast foods” (g/d) typically sold in fast-food restaurants and measured body mass index (BMI; in kg/m2) across geographic information system–derived home and work fast-food exposure quartiles. We used logistic regression to estimate the odds of obesity (BMI ≥30) and calculated relative excess risk due to interaction (RERI) on an additive scale. Participant data were collected during 2005–2013 and analyzed in 2015. Results: Greater fast-food consumption, BMI, and odds of obesity were associated with greater fast-food outlet exposure and a lower educational level. Fast-food consumption and BMI were significantly different across education groups at all levels of fast-food outlet exposure (P fast-food outlet exposure amplified differences in fast-food consumption across levels of education. The relation between fast-food outlet exposure and obesity was only significant among those who were least educated (OR: 2.05; 95% CI: 1.08, 3.87; RERI = 0.88), which suggested a positive additive interaction between education and fast-food outlet exposure. Conclusion: These findings suggest that efforts to improve diets and health through neighborhood-level fast-food outlet regulation might be effective across socioeconomic groups and may serve to reduce observed socioeconomic inequalities in diet and obesity. PMID

  16. Alcohol beverage control, privatization and the geographic distribution of alcohol outlets

    Directory of Open Access Journals (Sweden)

    Grubesic Tony H

    2012-11-01

    Full Text Available Abstract Background With Pennsylvania currently considering a move away from an Alcohol Beverage Control state to a privatized alcohol distribution system, this study uses a spatial analytical approach to examine potential impacts of privatization on the number and spatial distribution of alcohol outlets in the city of Philadelphia over a long time horizon. Methods A suite of geospatial data were acquired for Philadelphia, including 1,964 alcohol outlet locations, 569,928 land parcels, and school, church, hospital, park and playground locations. These data were used as inputs for exploratory spatial analysis to estimate the expected number of outlets that would eventually operate in Philadelphia. Constraints included proximity restrictions (based on current ordinances regulating outlet distribution of at least 200 feet between alcohol outlets and at least 300 feet between outlets and schools, churches, hospitals, parks and playgrounds. Results Findings suggest that current state policies on alcohol outlet distributions in Philadelphia are loosely enforced, with many areas exhibiting extremely high spatial densities of outlets that violate existing proximity restrictions. The spatial model indicates that an additional 1,115 outlets could open in Philadelphia if privatization was to occur and current proximity ordinances were maintained. Conclusions The study reveals that spatial analytical approaches can function as an excellent tool for contingency-based “what-if” analysis, providing an objective snapshot of potential policy outcomes prior to implementation. In this case, the likely outcome is a tremendous increase in alcohol outlets in Philadelphia, with concomitant negative health, crime and quality of life outcomes that accompany such an increase.

  17. Hydrologic Outlets of the Greenland Ice Sheet, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Hydrologic Outlets of the Greenland Ice Sheet data set contains GIS point shapefiles that include 891 observed and potential hydrologic outlets of the Greenland...

  18. AGU hydrology publication outlets

    Science.gov (United States)

    Freeze, R. Allan

    In recent months I have been approached on several occasions by members of the hydrology community who asked me which of the various AGU journals and publishing outlets would be most suitable for a particular paper or article that they have prepared.Water Resources Research (WRR) is the primary AGU outlet for research papers in hydrology. It is an interdisciplinary journal that integrates research in the social and natural sciences of water. The editors of WRR invite original contributions in the physical, chemical and biological sciences and also in the social and policy sciences, including economics, systems analysis, sociology, and law. The editor for the physical sciences side of the journal is Donald R. Nielson, LAWR Veihmeyer Hall, University of California Davis, Davis, CA 95616. The editor for the policy sciences side of the journal is Ronald G. Cummings, Department of Economics, University of New Mexico, Albuquerque, NM 87131

  19. An experimental study about effect of far infrared radiant ceramics on efficient methane fermentation

    International Nuclear Information System (INIS)

    Oda, A.; Yamazaki, M.; Oida, A.

    2003-01-01

    Methane fermentation, well known as one of the methods for organic wastes treatment, has been used as an energy production process in order to produce a gaseous fuel. But methane fermentation has some problems to be solved about gas production rate and volatile solids reduction efficiency. Simple methods to improve these problems are needed. In this study, we focused on far infrared radiant ceramics as a stimulating substance to activate methanogenic bacteria. Firstly, through the experiment of one batch fermentation, it was confirmed that the ceramics in the fermenter caused increase of total gas production. Next, even through the experiment of continuous fermentation, same stimulating effect was confirmed. It was considered that this effect was caused not only by a function of bio-contactor of the ceramics but also by far infrared radiation from ceramics. (author)

  20. Acute Alcohol Consumption, Alcohol Outlets, and Gun Suicide

    Science.gov (United States)

    Branas, Charles C.; Richmond, Therese S.; Ten Have, Thomas R.; Wiebe, Douglas J.

    2014-01-01

    A case–control study of 149 intentionally self-inflicted gun injury cases (including completed gun suicides) and 302 population-based controls was conducted from 2003 to 2006 in a major US city. Two focal independent variables, acute alcohol consumption and alcohol outlet availability, were measured. Conditional logistic regression was adjusted for confounding variables. Gun suicide risk to individuals in areas of high alcohol outlet availability was less than the gun suicide risk they incurred from acute alcohol consumption, especially to excess. This corroborates prior work but also uncovers new information about the relationships between acute alcohol consumption, alcohol outlets, and gun suicide. Study limitations and implications are discussed. PMID:21929327

  1. Integrated thermal infrared imaging and Structure-from-Motion photogrametry to map apparent temperature and radiant hydrothermal heat flux at Mammoth Mountain, CA USA

    Science.gov (United States)

    Lewis, Aaron; George Hilley,; Lewicki, Jennifer L.

    2015-01-01

    This work presents a method to create high-resolution (cm-scale) orthorectified and georeferenced maps of apparent surface temperature and radiant hydrothermal heat flux and estimate the radiant hydrothermal heat emission rate from a study area. A ground-based thermal infrared (TIR) camera was used to collect (1) a set of overlapping and offset visible imagery around the study area during the daytime and (2) time series of co-located visible and TIR imagery at one or more sites within the study area from pre-dawn to daytime. Daytime visible imagery was processed using the Structure-from-Motion photogrammetric method to create a digital elevation model onto which pre-dawn TIR imagery was orthorectified and georeferenced. Three-dimensional maps of apparent surface temperature and radiant hydrothermal heat flux were then visualized and analyzed from various computer platforms (e.g., Google Earth, ArcGIS). We demonstrate this method at the Mammoth Mountain fumarole area on Mammoth Mountain, CA. Time-averaged apparent surface temperatures and radiant hydrothermal heat fluxes were observed up to 73.7 oC and 450 W m-2, respectively, while the estimated radiant hydrothermal heat emission rate from the area was 1.54 kW. Results should provide a basis for monitoring potential volcanic unrest and mitigating hydrothermal heat-related hazards on the volcano.

  2. The efficacy of radiant heat controls on workers' heat stress around the blast furnace of a steel industry.

    Science.gov (United States)

    Giahi, Omid; Darvishi, Ebrahim; Aliabadi, Mohsen; Khoubi, Jamshid

    2015-01-01

    Workers' exposure to excessive heat in molten industries is mainly due to radiant heat from hot sources. The aim of this study was to evaluate the efficacy of radiant heat controls on workers heat stress around a typical blast furnace. Two main interventions were applied for reducing radiant heat around the blast furnace of a steel industry located in western Iran. These included using a heat absorbing system in the furnace body and installing reflective aluminum barrier in the main workstation. Heat stress indexes were measured before and after each intervention using the digital WBGT-meter. The results showed MRT and WBGT indexes decreased by 20 °C and 3.9 °C, respectively after using heat absorbing system and also decreased by 18.6 °C and 2.5 °C, respectively after installing a reflective barrier. These indexes decrease by 26.5 °C and 5.2 °C, respectively due to the simultaneous application of the two interventions which were statistically significant (p steel industries.

  3. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  4. The availability and accessibility of nutrition information in fast food outlets in five states post-menu labelling legislation in New South Wales.

    Science.gov (United States)

    Wellard, Lyndal; Havill, Michelle; Hughes, Clare; Watson, Wendy L; Chapman, Kathy

    2015-12-01

    1) Explore the availability and accessibility of fast food energy and nutrient information post-NSW menu labelling legislation in states with and without menu labelling legislation. 2) Determine whether availability and accessibility differed compared with pre-menu labelling legislation in NSW. We visited 210 outlets of the five largest fast food chains in five Australian states to observe the availability and accessibility of energy and nutrient information. Results were compared with 197 outlets surveyed pre-menu labelling. Most outlets (95%) provided energy values, half provided nutrient values and 3% provided information for all menu items. The total amount of information available increased post-NSW menu labelling implementation (473 versus 178 pre-implementation, pFast food chains surveyed had voluntarily introduced menu labelling nationally. However, more nutrient information was available in-store in 2010, showing that fast food chains are able to provide comprehensive nutrition information, yet they have stopped doing so. Menu labelling legislation should compel fast food chains to provide accessible nutrition information including nutrient values in addition to energy for all menu items in-store. Additionally, public education campaigns are needed to ensure customers can use menu labelling. © 2015 Public Health Association of Australia.

  5. Optimal Scheduling of Residential Microgrids Considering Virtual Energy Storage System

    Directory of Open Access Journals (Sweden)

    Weiliang Liu

    2018-04-01

    Full Text Available The increasingly complex residential microgrids (r-microgrid consisting of renewable generation, energy storage systems, and residential buildings require a more intelligent scheduling method. Firstly, aiming at the radiant floor heating/cooling system widely utilized in residential buildings, the mathematical relationship between the operative temperature and heating/cooling demand is established based on the equivalent thermodynamic parameters (ETP model, by which the thermal storage capacity is analyzed. Secondly, the radiant floor heating/cooling system is treated as virtual energy storage system (VESS, and an optimization model based on mixed-integer nonlinear programming (MINLP for r-microgrid scheduling is established which takes thermal comfort level and economy as the optimization objectives. Finally, the optimal scheduling results of two typical r-microgrids are analyzed. Case studies demonstrate that the proposed scheduling method can effectively employ the thermal storage capacity of radiant floor heating/cooling system, thus lowering the operating cost of the r-microgrid effectively while ensuring the thermal comfort level of users.

  6. Control characteristics and heating performance analysis of automatic thermostatic valves for radiant slab heating system in residential apartments

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byung-Cheon [Department of Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea); Song, Jae-Yeob [Graduate School, Building Equipment System Engineering, Kyungwon University, Seongnam City (Korea)

    2010-04-15

    Computer simulations and experiments are carried out to research the control characteristics and heating performances for a radiant slab heating system with automatic thermostatic valves in residential apartments. An electrical equivalent R-C circuit is applied to analyze the unsteady heat transfer in the house. In addition, the radiant heat transfer between slabs, ceilings and walls in the room is evaluated by enclosure analysis method. Results of heating performance and control characteristics were determined from control methods such as automatic thermostatic valves, room air temperature-sensing method, water-temperature-sensing method, proportional control method, and On-Off control method. (author)

  7. A longitudinal analysis of alcohol outlet density and domestic violence.

    Science.gov (United States)

    Livingston, Michael

    2011-05-01

    A small number of studies have identified a positive relationship between alcohol outlet density and domestic violence. These studies have all been based on cross-sectional data and have been limited to the assessment of ecological correlations between outlet density and domestic violence rates. This study provides the first longitudinal examination of this relationship. Cross-sectional time-series using aggregated data from small areas. The relationships between alcohol outlet density and domestic violence were assessed over time using a fixed-effects model. Controls for the spatial autocorrelation of the data were included in the model. The study uses data for 186 postcodes from within the metropolitan area of Melbourne, Australia for the years 1996 to 2005. Alcohol outlet density measures for three different types of outlets (hotel/pub, packaged liquor, on-premise) were derived from liquor licensing records and domestic violence rates were calculated from police-recorded crime data, based on the victim's postcode. Alcohol outlet density was associated significantly with rates of domestic violence, over time. All three licence categories were positively associated with domestic violence rates, with small effects for general (pub) and on-premise licences and a large effect for packaged liquor licences. In Melbourne, the density of liquor licences is positively associated with rates of domestic violence over time. The effects were particularly large for packaged liquor outlets, suggesting a need for licensing policies that pay more attention to o off-premise alcohol availability. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  8. Application of roof radiant burners in large pusher-type furnaces

    Directory of Open Access Journals (Sweden)

    A. Varga

    2009-07-01

    Full Text Available The paper deals with the application of roof flat-flame burners in the pusher-type steel slab reheating furnaces, after furnace reconstruction and replacement of conventional torch burners, with the objective to increase the efficiency of radiative heat transfer from the refractory roof to the charge. Based on observations and on measurements of the construction and process parameters under operating conditions, the advantages and disadvantages of indirectly oriented radiant heat transfer are analysed in relation to the heat transfer in classically fired furnaces.

  9. Gastric Outlet Obstruction from Duodenal Lipoma in an Adult ...

    African Journals Online (AJOL)

    Gastric Outlet Obstruction from Duodenal Lipoma in an Adult. ... Nigerian Journal of Surgery ... Although, peptic ulcer disease remains the most common benign cause of gastric outlet obstruction (GOO), duodenal lipomas remain a rare, but possible cause of GOO and could pose a diagnostic challenge, especially in ...

  10. Clouds and the Earth's Radiant Energy System (CERES) algorithm theoretical basis document. volume 2; Geolocation, calibration, and ERBE-like analyses (subsystems 1-3)

    Science.gov (United States)

    Wielicki, B. A. (Principal Investigator); Barkstrom, B. R. (Principal Investigator); Charlock, T. P.; Baum, B. A.; Green, R. N.; Minnis, P.; Smith, G. L.; Coakley, J. A.; Randall, D. R.; Lee, R. B., III

    1995-01-01

    The theoretical bases for the Release 1 algorithms that will be used to process satellite data for investigation of the Clouds and Earth's Radiant Energy System (CERES) are described. The architecture for software implementation of the methodologies is outlined. Volume 2 details the techniques used to geolocate and calibrate the CERES scanning radiometer measurements of shortwave and longwave radiance to invert the radiances to top-of-the-atmosphere (TOA) and surface fluxes following the Earth Radiation Budget Experiment (ERBE) approach, and to average the fluxes over various time and spatial scales to produce an ERBE-like product. Spacecraft ephemeris and sensor telemetry are used with calibration coefficients to produce a chronologically ordered data product called bidirectional scan (BDS) radiances. A spatially organized instrument Earth scan product is developed for the cloud-processing subsystem. The ERBE-like inversion subsystem converts BDS radiances to unfiltered instantaneous TOA and surface fluxes. The TOA fluxes are determined by using established ERBE techniques. Hourly TOA fluxes are computed from the instantaneous values by using ERBE methods. Hourly surface fluxes are estimated from TOA fluxes by using simple parameterizations based on recent research. The averaging process produces daily, monthly-hourly, and monthly means of TOA and surface fluxes at various scales. This product provides a continuation of the ERBE record.

  11. Calculation codes for radiant heat transfers; Les codes de calcul de rayonnement thermique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    This document reports on 12 papers about computerized simulation and modeling of radiant heat transfers and fluid flows in various industrial and domestic situations: space heating, metal industry (furnaces, boilers..), aerospace industry (turbojet engines, combustion chambers) etc.. This workshop was organized by the ``radiation`` section of the French society of thermal engineers. (J.S.)

  12. Calculation codes for radiant heat transfers; Les codes de calcul de rayonnement thermique

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This document reports on 12 papers about computerized simulation and modeling of radiant heat transfers and fluid flows in various industrial and domestic situations: space heating, metal industry (furnaces, boilers..), aerospace industry (turbojet engines, combustion chambers) etc.. This workshop was organized by the ``radiation`` section of the French society of thermal engineers. (J.S.)

  13. Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.

    Science.gov (United States)

    Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie

    2008-01-01

    We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.

  14. Effect of radiant heat transfer on the performance of high temperature heat exchanger

    International Nuclear Information System (INIS)

    Mori, Yasuo; Hijikata, Kunio; Yamada, Yukio

    1975-01-01

    The development of high temperature gas-cooled reactors is motivated by the consideration of the application of nuclear heat for industrial uses or direct steelmaking and chemical processes. For these purposes, reliable and efficient heat exchangers should be developed. This report analyzes the effect of radiant heat transfer on the performance of high temperature heat exchangers. The heat transfer model is as follows: the channel composed with two parallel adiabatic walls is divided with one parallel plate between the walls. Non-radiative fluid flows in the two separated channels in opposite direction. Heat transfer equations for this system were obtained, and these equations were solved by some approximate method and numerical analysis. The effect of radiation on heat transfer became larger as the radiant heat transfer between two walls was larger. In the heat exchangers of counter flow type, the thermal efficiency is controlled with three parameters, namely radiation-convection parameter, Stanton number and temperature difference. The thermal efficiency was larger with the increase of these parameters. (Iwase, T.)

  15. Non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner

    Energy Technology Data Exchange (ETDEWEB)

    Catapan, R.C.; Costa, M. [Mechanical Engineering Department, Instituto Superior Tecnico, Technical University of Lisbon, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Oliveira, A.A.M. [Mechanical Engineering Department, Federal University of Santa Catarina, Campus Universitario Professor Joao David Ferreira Lima, 88040-900 Florianopolis, SC (Brazil)

    2011-01-15

    Industrial processes where the heating of large surfaces is required lead to the possibility of using large surface porous radiant burners. This causes additional temperature uniformity problems, since it is increasingly difficult to evenly distribute the reactant mixture over a large burner surface while retaining its stability and keeping low pollutant emissions. In order to allow for larger surface area burners, a non-uniform velocity profile mechanism for flame stabilization in a porous radiant burner using a single large injection hole is proposed and analyzed for a double-layered burner operating in open and closed hot (laboratory-scale furnace, with temperature-controlled, isothermal walls) environments. In both environments, local mean temperatures within the porous medium have been measured. For lower reactant flow rate and ambient temperature the flame shape is conical and anchored at the rim of the injection hole. As the volumetric flow rate or furnace temperature is raised, the flame undergoes a transition to a plane flame stabilized near the external burner surface. However, the stability range envelope remains the same in both regimes. (author)

  16. Evaluation of alcohol outlet density and its relation with violence

    Directory of Open Access Journals (Sweden)

    Laranjeira Ronaldo

    2002-01-01

    Full Text Available OBJECTIVES: The current study set out to investigate alcohol availability in a densely populated, residential area of suburban São Paulo associated with high levels of social deprivation and violence. Gun-related deaths and a heavy concentration of alcohol outlets are notable features of the area surveyed. Given the strong evidence for a link between alcohol availability and a number of alcohol-related problems, including violent crime, measures designed to reduce accessibility have become a favored choice for alcohol prevention programs in recent years. METHODS: The interviewers were 24 residents of the area who were trained for the study. It was selected an area of nineteen streets, covering a total distance of 3.7 km. A profile of each alcohol outlet available on the area was recorded. RESULTS: One hundred and seven alcohol outlets were recorded. The number of other properties in the same area was counted at 1,202. Two measures of outlet density may thus be calculated: the number of outlets per kilometer of roadway (29 outlets/km; and the proportion of all properties that sold alcohol (1 in 12. CONCLUSIONS: The results of this study is compared with others which are mainly from developed countries and shown that the area studied have the highest density of alcohol outlet density ever recorded in the medical literature. The implication of this data related to the violence of the region is discussed. By generating a profile of alcohol sales and selling points, it was hoped to gain a better understanding of alcohol access issues within the sample area. Future alcohol prevention policy would be well served by such knowledge.

  17. Simulation of an under-floor heating system integrated with solar energy under the weather conditions of Beirut

    Energy Technology Data Exchange (ETDEWEB)

    Kattan, Patrick; Ghali, Kamel [American University of Beirut (Lebanon)], email: pek01@aub.edu.lb, email: ka04@aub.edu.lb

    2011-07-01

    Residential heating indoors can use convective systems, where hot air is blown into the space, or radiant systems, where a radiant panel transfers heat via both convection and radiation. Radiant systems can provide thermal comfort for less energy by directly heating the human body. The aim of this paper is to assess the feasibility of using under-floor solar energy heating systems in the climatic conditions of Beirut. An under-floor heating system with solar/diesel energy system was developed and optimized specifically for Beirut. Results showed that the system could lead to 38% energy savings and a 96% reduction in CO2 emissions with a solar fraction of 95%. An economic analysis was also performed using incremental prices of diesel costs and the cost of land for the installation; it yielded a figure of 19000$/m2 savings over the system's lifetime. This study demonstrated that the use of an under-floor heating system with solar energy in Beirut would have ecological and economic benefits.

  18. Ectopic pancreas causing partial gastric outlet obstruction: a case ...

    African Journals Online (AJOL)

    Ectopic pancreas causing partial gastric outlet obstruction: a case report and review of literature. ... Nigerian Journal of Surgery ... Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center; we, therefore, present this case to describe the challenges faced with diagnosis, treatment, ...

  19. Ectopic Pancreas Causing Partial Gastric Outlet Obstruction: A Case ...

    African Journals Online (AJOL)

    Ectopic pancreas is a rare cause of gastric outlet obstruction, perhaps rarer still among Africans. Although the entity is known, the diagnostic challenges are enormous, especially in the poor‑resource environment. Gastric outlet obstruction resulting from ectopic pancreas in an adult is the first of its kind in our center;.

  20. Radiant-and-plasma technology for coal processing

    Directory of Open Access Journals (Sweden)

    Vladimir Messerle

    2012-12-01

    Full Text Available Radiant-and-plasma technology for coal processing is presented in the article. Thermodynamic computation and experiments on plasma processing of bituminous coal preliminary electron-beam activated were fulfilled in comparison with plasma processing of the coal. Positive influence of the preliminary electron-beam activation of coal on synthesis gas yield was found. Experiments were carried out in the plasma gasifier of 100 kW power. As a result of the measurements of material and heat balance of the process gave the following integral indicators: weight-average temperature of 2200-2300 K, and carbon gasification degree of 82,4-83,2%. Synthesis gas yield at thermochemical preparation of raw coal dust for burning was 24,5% and in the case of electron-beam activation of coal synthesis gas yield reached 36,4%, which is 48% higher.

  1. Radiant science, dark politics: a memoir of the nuclear age

    International Nuclear Information System (INIS)

    Kamen, M.D.

    1985-01-01

    The reviewer describes Radiant Science, Dark Politics: A Memoir of the Nuclear Age in contrast to a memoir by James R. Killian, Jr., a contemporary of Kamen. Kamen, co-discoverer of carbon-14 and a valued member of the Berkeley Radiation Laboratory, was fired in 1944 and blackballed as a security risk. Rehabilitated by the end of the war, his continued fight against political injustice through the McCarthy era colors the book and, for the reviewer, makes it self-serving. Kamen's later scientific work reflected his desire to work alone rather than in collaboration

  2. Laboratory services series: an electrical outlet and corded equipment inspection program

    International Nuclear Information System (INIS)

    Davis, E.A.

    1976-04-01

    A research and development laboratory has thousands of electrical outlets providing power to laboratories, offices, shops, and service areas. These outlets provide power for a wide variety of portable equipment and tools that are equipped with cord and plug. Electric safety requires a periodic check of outlet grounding capability and continuing inspection and repair of corded equipment. Personnel, equipment, reports, procedures, and schedule requirements are reported

  3. Alcohol outlet density and alcohol consumption in Los Angeles county and southern Louisiana

    Directory of Open Access Journals (Sweden)

    Matthias Schonlau

    2008-11-01

    Full Text Available The objective of this study was to assess the relationship between alcohol availability, as measured by the density of off-premise alcohol outlets, and alcohol consumption in Los Angeles county and southern Louisiana, USA. Consumption information was collected through a telephone survey of 2,881 households in Los Angeles county and pre-Katrina southern Louisiana, nested within 220 census tracts. Respondents’ addresses were geo-coded and both neighbourhood (census tracts and buffers of varying sizes and individual (network distance to the closest alcohol outlet estimates of off-sale alcohol outlet density were computed. Alcohol outlet density was not associated with the percentage of people who were drinkers in either site. Alcohol outlet density was associated with the quantity of consumption among drinkers in Louisiana but not in Los Angeles. Outlet density within a one-mile buffer of the respondent’s home was more strongly associated with alcohol consumption than outlet density in the respondent’s census tract. The conclusion is that the relationship between neighbourhood alcohol outlet density and alcohol consumption is complex and may vary due to differences in neighbourhood design and travel patterns.

  4. Study of thermosiphon and radiant panel passive heating systems for metal buildings

    Energy Technology Data Exchange (ETDEWEB)

    Biehl, F.A.; Schnurr, N.M.; Wray, W.O.

    1983-01-01

    A study of passive-heating systems appropriate for use on metal buildings is being conducted at Los Alamos National Laboratory for the Naval Civil Engineering Laboratory, Port Hueneme, California. The systems selected for study were chosen on the basis of their appropriateness for retrofit applications, although they are also suitable for new construction: simple radiant panels that communicate directly with the building interior and a backflow thermosiphon that provides heat indirectly.

  5. Newborns' temperature submitted to radiant heat and to the Top Maternal device at birth.

    Science.gov (United States)

    Albuquerque, Rosemeire Sartori de; Mariani, Corintio; Bersusa, Ana Aparecida Sanches; Dias, Vanessa Macedo; Silva, Maria Izabel Mota da

    2016-08-08

    to compare the axillar temperatures of newborns that are put immediately after birth in skin-to-skin contact under the Top Maternal device, as compared to those in a radiant heat crib. comparatives observational study of the case-control type about temperature of 60 babies born at the Obstetric Center and Normal Delivery Center of a public hospital of the municipality of Sao Paulo, being them: 29 receiving assistance in heated crib and 31 in skin-to skin contact, shielded by a cotton tissue placed on mother's thorax, called Top Maternal. the temperature of the babies of the skin-to-skin contact group presented higher values in a larger share of the time measures verified, as compared to those that were placed in radiant heat crib, independently from the place of birth. Differences between the two groups were not statistically significant. the study contributes to generate new knowledge, supporting the idea of keeping babies with their mothers immediately after birth protected with the Maternal Top, without harming their wellbeing, as it keeps the axillar temperature in recommendable levels. comparar a temperatura axilar dos recém-nascidos acomodados - imediatamente após o nascimento - em contato pele a pele, sob o Top Maternal, em berço de calor radiante. estudo comparativo observacional do tipo Caso-Controle sobre a temperatura de 60 bebês nascidos no Centro Obstétrico e Centro de Parto Normal de um hospital público do município de São Paulo, sendo: 29 assistidos em berço aquecido e 31 em contato pele a pele, protegidos por uma malha de algodão colocada sobre o tórax da mãe, denominada Top Maternal. a temperatura dos bebês do grupo de contato pele a pele teve maior valor na maioria dos tempos verificados comparada à dos que foram colocados em berço de calor radiante, independentemente do local de nascimento. A diferença entre os grupos não foi estatisticamente significante. o estudo contribui com a geração de um novo conhecimento que sustenta a

  6. Radiant Research. Institute for Energy Technology 1948-98

    International Nuclear Information System (INIS)

    Njoelstad, Olav

    1999-01-01

    Institutt for Atomenergi (IFA), or Institute for Atomic Energy, at Kjeller, Norway, was founded in 1948. The history of the institute as given in this book was published in 1999 on the occasion of the institute's 50th anniversary. The scope of the institute was to do research and development as a foundation for peaceful application of nuclear energy and radioactive substances in Norway. The book tells the story of how Norway in 1951 became the first country after the four superpowers and Canada to have its own research reactor. After the completion of the reactor, the institute experienced a long and successful period and became the biggest scientific and technological research institute in Norway. Three more reactors were built, one in Halden and two at Kjeller. Plans were developed to build nuclear powered ships and nuclear power stations. It became clear, however, in the 1970s, that there was no longer political support for nuclear power in Norway, and it was necessary for the institute to change its research profile. In 1980, the institute changed its name to Institutt for energiteknikk (IFE), or Institute for energy technology, to signal the broadened scope. The book describes this painful but successful readjustment and shows how IFE in the 1980s and 1990s succeeded in using its special competence from the nuclear field to establish special competence in new research fields with great commercial potential

  7. High-temperature process heat reactor with solid coolant and radiant heat exchange

    International Nuclear Information System (INIS)

    Alekseev, A.M.; Bulkin, Yu.M.; Vasil'ev, S.I.

    1984-01-01

    The high temperature graphite reactor with the solid coolant in which heat transfer is realized by radiant heat exchange is described. Neutron-physical and thermal-technological features of the reactor are considered. The reactor vessel is made of sheet carbon steel in the form of a sealed rectangular annular box. The moderator is a set of graphite blocks mounted as rows of arched laying Between the moderator rows the solid coolant annular layings made of graphite blocks with high temperature nuclear fuel in the form of coated microparticles are placed. The coolant layings are mounted onto ring movable platforms, the continuous rotation of which is realizod by special electric drives. Each part of the graphite coolant laying consecutively passes through the reactor core neutron cut-off zones and technological zone. In the core the graphite is heated up to the temperature of 1350 deg C sufficient for effective radiant heat transfer. In the neutron cut-off zone the chain reaction and further graphite heating are stopped. In the technological zone the graphite transfers the accumulated heat to the walls of technological channels in which the working medium moves. The described reactor is supposed to be used in nuclear-chemical complex for ammonia production by the method of methane steam catalytic conversion

  8. Standard Terminology Relating to Photovoltaic Solar Energy Conversion

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This terminology pertains to photovoltaic (radiant-to-electrical energy conversion) device performance measurements and is not a comprehensive list of terminology for photovoltaics in general. 1.2 Additional terms used in this terminology and of interest to solar energy may be found in Terminology E 772.

  9. Optimal design approach for heating irregular-shaped objects in three-dimensional radiant furnaces using a hybrid genetic algorithm-artificial neural network method

    Science.gov (United States)

    Darvishvand, Leila; Kamkari, Babak; Kowsary, Farshad

    2018-03-01

    In this article, a new hybrid method based on the combination of the genetic algorithm (GA) and artificial neural network (ANN) is developed to optimize the design of three-dimensional (3-D) radiant furnaces. A 3-D irregular shape design body (DB) heated inside a 3-D radiant furnace is considered as a case study. The uniform thermal conditions on the DB surfaces are obtained by minimizing an objective function. An ANN is developed to predict the objective function value which is trained through the data produced by applying the Monte Carlo method. The trained ANN is used in conjunction with the GA to find the optimal design variables. The results show that the computational time using the GA-ANN approach is significantly less than that of the conventional method. It is concluded that the integration of the ANN with GA is an efficient technique for optimization of the radiant furnaces.

  10. PAIR INFLUENCE OF WIND SPEED AND MEAN RADIANT TEMPERATURE ON OUTDOOR THERMAL COMFORT OF HUMID TROPICAL ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    Sangkertadi Sangkertadi

    2016-01-01

    Full Text Available The purposes of this article is to explore knowledge of outdoor thermal comfort in humid tropical environment for urban activities especially for people in walking activity, and those who stationary/seated with moderate action. It will be characterized the pair influence of wind speed and radiant temperature on the outdoor thermal comfort. Many of researchers stated that those two microclimate variables give significant role on outdoor thermal comfort in tropical humid area. Outdoor Tropical Comfort (OTC model was used for simulation in this study. The model output is comfort scale that refers on ASHRAE definition. The model consists of two regression equations with variables of air temperature, globe temperature, wind speed, humidity and body posture, for two types of activity: walking and seated. From the results it can be stated that there is significant role of wind speed to reduce mean radiant temperature and globe temperature, when the velocity is elevated from 0.5 m/s to 2 m/s. However, the wind has not play significant role when the speed is changed from 2 m/s to 3.5 m/s. The results of the study may inspire us to implement effectiveness of electrical-fan equipment for outdoor space in order to get optimum wind speed, coupled with optimum design of shading devices to minimize radiant temperature for thermal comfort.

  11. Radiant coolers - Theory, flight histories, design comparisons and future applications

    Science.gov (United States)

    Donohoe, M. J.; Sherman, A.; Hickman, D. E.

    1975-01-01

    Radiant coolers have been developed for application to the cooling of infrared detectors aboard NASA earth observation systems and as part of the Defense Meteorological Satellite Program. The prime design constraints for these coolers are the location of the cooler aboard the satellite and the satellite orbit. Flight data from several coolers indicates that, in general, design temperatures are achieved. However, potential problems relative to the contamination of cold surfaces are also revealed by the data. A comparison among the various cooler designs and flight performances indicates design improvements that can minimize the contamination problem in the future.

  12. Radiant and convective heat transfer for flow of a transparent gas in a short tube with prescribed sinusoidal wall heat flux

    International Nuclear Information System (INIS)

    de Lemos, M.J.S.

    1982-01-01

    The present analysis accounts for radiant and convective heat transfer for a transparent fluid flowing in a short tube with prescribed wall heat flux. The heat flux distribution used was of sine shape with maximum at the middle of the tube. Such a solution is the approximate one for axial power in a nuclear reactor. The solutions for the tube wall and gas bulk temperatures were obtained by successive substitutions for the wall and gas balance energy equations. The results show a decrease of 30% for the maximum wall temperature using black surface (e = 1). In this same case, the increasing in the gas temperature shows a decrease of 58%

  13. Prediction of radiant heat flux from horizontal propane jet fire

    International Nuclear Information System (INIS)

    Zhou, Kuibin; Liu, Jiaoyan; Jiang, Juncheng

    2016-01-01

    Highlights: • Line source model for the radiant heat flux from horizontal jet fire is proposed. • A review on the difference between horizontal and vertical jet fires is conducted. • Effects of lift-off distance and flame shape are discussed for the line source model. • Line source model gives encouraging results relative to the validity of model system. - Abstract: Jet fires are often reported to occur in process industry with lots of hazardous heat energy released. A line source model describing the flame emissive power and subsequent heat flux radiated from a horizontal propane jet fire is evaluated through a testing against experimental fire data and comparison against other models. By a review on the jet flame behavior, the correlations of the lift-off distance, flame length and radiative fraction are proposed to close the line source model in theory. It is found that the fuel jet direction holds a considerable effect on the flame behavior by comparison between horizontal and vertical jet fires. Results indicate that the lift-off distance and the flame shape influence the model prediction to some extent. Comparison of model predictions against data collected in the near field and predictions from the point source model and multipoint source model gives encouraging results relative to the validity of model system.

  14. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    Directory of Open Access Journals (Sweden)

    McIntosh Alex

    2008-11-01

    Full Text Available Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may provide most of the opportunities for procurement of fast foods. Methods Using all traditional and nontraditio nal fast-food outlets identified in six counties in rural Texas, the type and number of regular and healthiermenu options were surveyed using on-site observation in all food venues that were primarily fast food, supermarket/grocery store, and convenience store and compared with 2005 Dietary Guidelines. Results Traditional fast-food outlets represented 84 (41% of the 205 opportunities for procurement of fast food; 109 (53.2% were convenience stores and 12 (5.8% supermarkets/grocery stores. Although a s imilar variety of regular breakfast and lunch/dinner entrées were available in traditional fast-food outlets and convenience stores, the variety of healthier breakfast and lunch/dinner entrées was significantly greater in fast food outlets. Compared with convenience stores, supermarkets/grocery stores provided a greater variety of regular and healthier entrées and lunch/dinner side dishes. Conclusion Convenience stores and supermarkets/grocery stores more than double the potential access to fast foods in this rural area than traditional fast-food outlets alone; however, traditional fast food outlets offer greater opportunity for healthier fast food options than convenience stores. A complete picture of fast food environment and the availability of healthier fast food options are essential to understand environmental influences on diet and health

  15. Modular assembly of a photovoltaic solar energy receiver

    Science.gov (United States)

    Graven, Robert M.; Gorski, Anthony J.; Schertz, William W.; Graae, Johan E. A.

    1978-01-01

    There is provided a modular assembly of a solar energy concentrator having a photovoltaic energy receiver with passive cooling. Solar cell means are fixedly coupled to a radiant energy concentrator. Tension means bias a large area heat sink against the cell thereby allowing the cell to expand or contract with respect to the heat sink due to differential heat expansion.

  16. The energy balance of the earth's surface : a practical approach

    NARCIS (Netherlands)

    Bruin, de H.A.R.

    1982-01-01

    This study is devoted to the energy balance of the earth's surface with a special emphasis on practical applications. A simple picture of the energy exchange processes that take place at the ground is the following. Per unit time and area an amount of radiant energy is supplied to the surface. This

  17. Improvement on life and NO{sub x} discharge of radiant heat transfer tube heating system by the elasto-plasticity creep analysis; Dansosei kuripukaiseki ni yoru hosha dennetsukan kanetsu shisutemu no jumyo to NO{sub x} haishutsuryo no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Futahiko; Ikaruda, Kunihiro; Abe, Yoshio; Arai, Norio

    1999-06-05

    Combustion thermal process using the radiant heat transfer tube has widely been applied as a heating method which separates the combustion atmosphere from the heating-e atmosphere in various heating furnace such as iron and steel industry. In this thermal process, in order to burn the fuel in tight space in radiant heat transfer service area, radiant heat transfer tube and burner life were short under high temperature and high-load combustion, and there was a problem that that and, burning characteristic such as NO{sub x} generation rate are improved was difficult. In this study, large temperature distribution by the combustion in the radiant heat transfer tube clarified that the life of the radiant heat transfer tube was shortened by elasto-plasticity creep analysis of the radiant heat transfer tube. Then, two steps combustion burner of the exhaust gas self recycling type was developed as a method for reducing the NO{sub x} generation rate, while the temperature distribution of the radiant heat transfer tube was equalized. As the result, it was possible to reduce over 20% in comparison with conventional two steps combustion burner, while radiant heat transfer tube and life of the burner are extended over the conventional double, in respect of the NO{sub x} generation rate. (translated by NEDO)

  18. Assessing the accuracy of globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate

    Science.gov (United States)

    Khrit, N. G.; Alghoul, M. A.; Sopian, K.; Lahimer, A. A.; Elayeb, O. K.

    2017-11-01

    Assessing outdoor human thermal comfort and urban climate quality require experimental investigation of microclimatic conditions and their variations in open urban spaces. For this, it is essential to provide quantitative information on air temperature, humidity, wind velocity and mean radiant temperature. These parameters can be quantified directly except mean radiant temperature (Tmrt). The most accurate method to quantify Tmrt is integral radiation measurements (3-D shortwave and long-wave) which require using expensive radiometer instruments. To overcome this limitation the well-known globe thermometer method was suggested to calculate Tmrt. The aim of this study was to assess the possibility of using indoor globe thermometer method in predicting outdoor mean radiant temperature under Malaysia tropical microclimate. Globe thermometer method using small and large sizes of black-painted copper globes (50mm, 150mm) were used to estimate Tmrt and compare it with the reference Tmrt estimated by integral radiation method. The results revealed that the globe thermometer method considerably overestimated Tmrt during the middle of the day and slightly underestimated it in the morning and late evening. The difference between the two methods was obvious when the amount of incoming solar radiation was high. The results also showed that the effect of globe size on the estimated Tmrt is mostly small. Though, the estimated Tmrt by the small globe showed a relatively large amount of scattering caused by rapid changes in radiation and wind speed.

  19. Power source with spark-safe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Tsesarenko, N P; Alekhin, A V

    1982-01-01

    The invention refers to the technique of electrical monitoring and control in systems operating in a spark-safe medium (for example, in coal mines). A more accurate area of application is mobile objects with autonomous source of electricity (mine diesel locomotives, battery electric locomotives etc.). The purpose of the invention is to simplify and to improve the reliability of the planned device, and also to expand the area of application for conditions when it is powered from an autonomous generator of direct voltage. This goal is achieved because the power source with spark-safe outlet (the source contains a thyristor of advance disconnection, connected by anode to the delimiting throttle, one outlet of which is connected to the capacitor included between the controlling electrode and the anode of the thyristor, and the capacitor is connected through the resistor parallel to the outlet clamps of the source, while the thyristor of emergency protection connected parallel to the inlet clamps of the power source) is additionally equipped with a current sensor, hercon, transistor key (included in series in the power circuit) and optron, whose emitter is connected parallel to the current sensor connected in series to the inlet of the power source, while the receiver of the optron is connected in a circuit for controlling the thyristor of emergency protection. Hercon is built into the core of the delimiting throttle and is connected to the circuit for controlling the transistor key.

  20. The Role at Rehabilitation in Treatment of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hosseinian

    2003-01-01

    Full Text Available Objective: Thoracic outlet syndrome is a complex disorder caused by neurovascular irritation in the region of the thoracic outlet. The syndrome have been said to be mainly due to anomalous structures in the thoracic outlet, treatment for thoracic outlet syndrome varies among different institutions, and there has not been any standard program. In general conservative and surgical treatment can be do if necessary. Materials & Methods: The rehabilitation program consists of exercise and physiotherapy and brace designed to hold the posture in which thoracic outlet is enlarged. Exercise program was designed simple enough to be performed in the daily living or during work after minimal training and isometric exercises of Serratus anterior, Levator Scapulae and Erector Spinae muscles to be performed in one posture: flexion and elevation of scapular girdle and correction position of upper-thoracic spine. During 7 years, 131 cases of (T.O.S. were evaluated that 26 cases (20% have operated and 84 cases (64% have treated with conservative treatment and 21 cases (16% have been candidate for surgery but they didn't accepted. Results: All of the cases have treated with conservative treatment for four months. 84 cases responded well and no further treatment was needed. 47 cases were not satisfied with. The outcome of their treatment, that 26 cases have operated and 21 cases have not accepted the operation and continued the conservative treatment, they have had pain and slightly disability. 23 cases of operated group responded well and they have resumed to work, one case has had neuropraxia for about one year. Conclusion: Most cases of thoracic outlet syndrome (T.O.S. can be treated conservatively. Surgically treatment is indicated only in cases severe enough to make them disable to work. It is better all the patients undergo conservative treatment for at least four months then will decided for surgical treatment.

  1. Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Ioan Sarbu

    2016-03-01

    Full Text Available A ground-coupled heat pump (GCHP system used to provide the space heating for an office room is a renewable, high performance technology. This paper discusses vapour compression-based HP systems, briefly describing the thermodynamic cycle calculations, as well as the coefficient of performance (COP and CO2 emissions of a HP with an electro-compressor and compares different heating systems in terms of energy consumption, thermal comfort and environmental impact. It is focused on an experimental study performed to test the energy efficiency of the radiator or radiant floor heating system for an office room connected to a GCHP. The main performance parameters (COP and CO2 emissions are obtained for one month of operation of the GCHP system, and a comparative analysis of these parameters is presented. Additionally, two numerical simulation models of useful thermal energy and the system COP in heating mode are developed using the Transient Systems Simulation (TRNSYS software. Finally, the simulations obtained from TRNSYS software are analysed and compared to the experimental data, showing good agreement and thus validating the simulation models.

  2. Female outlet obstruction constipation: assessment with MR defecography

    International Nuclear Information System (INIS)

    Li Min; Jiang Tao; Yang Xinqing; Peng Peng; Wang Wenchuan

    2010-01-01

    Objective: Using MR defecography to assess the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and evaluate the joint disease of' anterior and mid pelvic. Methods: One hundred and seven female patients, aged 20 to 84 years (average, 55 years), were diagnosed as outlet obstruction constipation based on clinical symptoms and signs. They all received MR defecography in our institution. The high compliance homemade balloon was inserted into rectum to simulate stool. Then relevant measurements were obtained during rest, squeezing and straining, respectively. Results: In all the 107 cases, 70 (65.4%) presented rectocele on dynamic MRI; 28 (26.2%) presented anismus; 60 (56.1%) presented cystocele; 59 presented vaginal or cervical prolapse(55.1%); and, 54 (50.5%) presented descending perineum. In 85 females (79.4%) multiple disorders were detected, involving more than one pelvic compartment. Conclusion: MR defecography allowed to accurately evaluate the morphological and functional anorectal anomalies related to female outlet obstruction constipation, and the joint disease of anterior and mid pelvic. (authors)

  3. Everolimus in advanced, progressive, well-differentiated, non-functional neuroendocrine tumors: RADIANT-4 lung subgroup analysis.

    Science.gov (United States)

    Fazio, Nicola; Buzzoni, Roberto; Delle Fave, Gianfranco; Tesselaar, Margot E; Wolin, Edward; Van Cutsem, Eric; Tomassetti, Paola; Strosberg, Jonathan; Voi, Maurizio; Bubuteishvili-Pacaud, Lida; Ridolfi, Antonia; Herbst, Fabian; Tomasek, Jiri; Singh, Simron; Pavel, Marianne; Kulke, Matthew H; Valle, Juan W; Yao, James C

    2018-01-01

    In the phase III RADIANT-4 study, everolimus improved median progression-free survival (PFS) by 7.1 months in patients with advanced, progressive, well-differentiated (grade 1 or grade 2), non-functional lung or gastrointestinal neuroendocrine tumors (NETs) vs placebo (hazard ratio, 0.48; 95% confidence interval [CI], 0.35-0.67; P < .00001). This exploratory analysis reports the outcomes of the subgroup of patients with lung NETs. In RADIANT-4, patients were randomized (2:1) to everolimus 10 mg/d or placebo, both with best supportive care. This is a post hoc analysis of the lung subgroup with PFS, by central radiology review, as the primary endpoint; secondary endpoints included objective response rate and safety measures. Ninety of the 302 patients enrolled in the study had primary lung NET (everolimus, n = 63; placebo, n = 27). Median PFS (95% CI) by central review was 9.2 (6.8-10.9) months in the everolimus arm vs 3.6 (1.9-5.1) months in the placebo arm (hazard ratio, 0.50; 95% CI, 0.28-0.88). More patients who received everolimus (58%) experienced tumor shrinkage compared with placebo (13%). Most frequently reported (≥5% incidence) grade 3-4 drug-related adverse events (everolimus vs. placebo) included stomatitis (11% vs. 0%), hyperglycemia (10% vs. 0%), and any infections (8% vs. 0%). In patients with advanced, progressive, well-differentiated, non-functional lung NET, treatment with everolimus was associated with a median PFS improvement of 5.6 months, with a safety profile similar to that of the overall RADIANT-4 cohort. These results support the use of everolimus in patients with advanced, non-functional lung NET. The trial is registered with ClinicalTrials.gov (no. NCT01524783). © 2017 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.

  4. Greater access to fast-food outlets is associated with poorer bone health in young children.

    Science.gov (United States)

    Vogel, C; Parsons, C; Godfrey, K; Robinson, S; Harvey, N C; Inskip, H; Cooper, C; Baird, J

    2016-03-01

    A healthy diet positively influences childhood bone health, but how the food environment relates to bone development is unknown. Greater neighbourhood access to fast-food outlets was associated with lower bone mass among infants, while greater access to healthy speciality stores was associated with higher bone mass at 4 years. Identifying factors that contribute to optimal childhood bone development could help pinpoint strategies to improve long-term bone health. A healthy diet positively influences bone health from before birth and during childhood. This study addressed a gap in the literature by examining the relationship between residential neighbourhood food environment and bone mass in infants and children. One thousand one hundred and seven children participating in the Southampton Women's Survey, UK, underwent measurement of bone mineral density (BMD) and bone mineral content (BMC) at birth and 4 and/or 6 years by dual-energy X-ray absorptiometry (DXA). Cross-sectional observational data describing food outlets within the boundary of each participant's neighbourhood were used to derive three measures of the food environment: the counts of fast-food outlets, healthy speciality stores and supermarkets. Neighbourhood exposure to fast-food outlets was associated with lower BMD in infancy (β = -0.23 (z-score): 95% CI -0.38, -0.08) and lower BMC after adjustment for bone area and confounding variables (β = -0.17 (z-score): 95% CI -0.32, -0.02). Increasing neighbourhood exposure to healthy speciality stores was associated with higher BMD at 4 and 6 years (β = 0.16(z-score): 95% CI 0.00, 0.32 and β = 0.13(z-score): 95% CI -0.01, 0.26 respectively). The relationship with BMC after adjustment for bone area and confounding variables was statistically significant at 4 years, but not at 6 years. The neighbourhood food environment that pregnant mothers and young children are exposed may affect bone development during early childhood. If confirmed in

  5. Availability of healthier options in traditional and nontraditional rural fast-food outlets

    OpenAIRE

    Creel, Jennifer S; Sharkey, Joseph R; McIntosh, Alex; Anding, Jenna; Huber, J Charles

    2008-01-01

    Abstract Background Food prepared away from home has become increasingly popular to U.S. families, and may contribute to obesity. Sales have been dominated by fast food outlets, where meals are purchased for dining away from home or in the home. Although national chain affiliated fast-food outlets are considered the main source for fast food, fast foods are increasingly available in convenience stores and supermarkets/grocery stores. In rural areas, these nontraditional fast-food outlets may ...

  6. Impact of remodeling and rehabilitation of irrigation outlets on water distribution of a canal in Punjab, Pakistan

    International Nuclear Information System (INIS)

    Bodla, H.; Latif, M.

    2009-01-01

    The study was undertaken to investigate water distribution along a distributary canal located in the southern part of the Punjab Province. It is a large size distributary having 353 cusecs of authorized discharge. This distributary was subjected to a series of problems including but not limited to (i) withdrawal of water by illegal means, (ii) design and construction flaws in the outlets, (iii) improper selection of the type of outlets and many others. The outlets were intentionally designed wrongly by using fictitious hydraulics data to provide undue benefits to the irrigators. During construction, setting of the outlets was also intentionally fixed at lower level than the designed. Investigations were carried out to evaluate hydraulic performance of all the outlets of the channel. Based on the observed data capacity statements of all the outlets were revised. The outlets were redesigned on the basis of actual hydraulic data of each outlet. Most of the non-modular outlets (Pipe and Scratchley) were converted to semi-modular outlets (OFRB and APM). With implementation of new and modified design of the outlets at the site, equity of water distribution has been improved. The results revealed that design of the outlets had a significant impact on equitable distribution of water along the distribution. (author)

  7. Benign Strictures of the Esophagus and Gastric Outlet: Interventional Management

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Shin, Ji Hoon; Song, Ho Young [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2010-10-15

    Benign strictures of the esophagus and gastric outlet are difficult to manage conservatively and they usually require intervention to relieve dysphagia or to treat the stricture-related complications. In this article, authors review the non-surgical options that are used to treat benign strictures of the esophagus and gastric outlet, including balloon dilation, temporary stent placement, intralesional steroid injection and incisional therapy

  8. Using public health and community partnerships to reduce density of alcohol outlets.

    Science.gov (United States)

    Jernigan, David H; Sparks, Michael; Yang, Evelyn; Schwartz, Randy

    2013-04-11

    Excessive alcohol use causes approximately 80,000 deaths in the United States each year. The Guide to Community Preventive Services recommends reducing the density of alcohol outlets - the number of physical locations in which alcoholic beverages are available for purchase either per area or per population - through the use of regulatory authority as an effective strategy for reducing excessive alcohol consumption and related harms. We briefly review the research on density of alcohol outlets and public health and describe the powers localities have to influence alcohol outlet density. We summarize Regulating Alcohol Outlet Density: An Action Guide, which describes steps that local communities can take to reduce outlet density and the key competencies and resources of state and local health departments. These include expertise in public health surveillance and evaluation methods, identification and tracking of outcome measures, geographic information systems (GIS) mapping, community planning and development of multisector efforts, and education of community leaders and policy makers. We illustrate the potential for partnerships between public health agencies and local communities by presenting a contemporary case study from Omaha, Nebraska. Public health agencies have a vital and necessary role to play in efforts to reduce alcohol outlet density. They are often unaware of the potential of this strategy and have strong potential partners in the thousands of community coalitions nationwide that are focused on reducing alcohol-related problems.

  9. Potency of Solar Energy Applications in Indonesia

    OpenAIRE

    Handayani, Noer Abyor; Ariyanti, Dessy

    2012-01-01

    Currently, 80% of conventional energy is used to fulfill general public's needs andindustries. The depletion of oil and gas reserves and rapid growth in conventional energyconsumption have continuously forced us to discover renewable energy sources, like solar, wind,biomass, and hydropower, to support economic development in the future. Solar energy travels at aspeed of 186,000 miles per second. Only a small part of the radiant energy that the sun emits intospace ever reaches the Earth, but t...

  10. Validation of presence of supermarkets and fast-food outlets in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida M; Holstein, Bjørn E; Due, Pernille

    2012-01-01

    We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field.......We examined the quality of food outlet addresses provided by secondary sources and determined whether they could be physically located in the field....

  11. Experimental study including subjective evaluations of mixing and displacement ventilation combined with radiant floor heating/cooling system

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2013-01-01

    Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation systems and radiant heating/cooling systems. In the first two tests, the simulated residential room was equipped either by a mixing ventilation system supplying warm air for space heat...

  12. Beyond Supermarkets: Food Outlet Location Selection in Four U.S. Cities Over Time.

    Science.gov (United States)

    Rummo, Pasquale E; Guilkey, David K; Ng, Shu Wen; Popkin, Barry M; Evenson, Kelly R; Gordon-Larsen, Penny

    2017-03-01

    Understanding what influences where food outlets locate is important for mitigating disparities in access to healthy food outlets. However, few studies have examined how neighborhood characteristics influence the neighborhood food environment over time, and whether these relationships differ by neighborhood-level income. Neighborhood-level data from four U.S. cities (Birmingham, AL; Chicago, IL; Minneapolis, MN; Oakland, CA) from 1986, 1993, 1996, 2001, 2006, and 2011 were used with two-step econometric models to estimate longitudinal associations between neighborhood-level characteristics (z-scores) and the log-transformed count/km 2 (density) of food outlets within real estate-derived neighborhoods. Associations were examined with lagged neighborhood-level sociodemographics and lagged density of food outlets, with interaction terms for neighborhood-level income. Data were analyzed in 2016. Neighborhood-level income at earlier years was negatively associated with the current density of convenience stores (β= -0.27, 95% CI= -0.16, -0.38, prestaurant density in low-income neighborhoods (10th percentile of income: β= -0.17, 95% CI= -0.34, -0.002, p=0.05), and the density of smaller grocery stores across all income levels (β= -0.27, 95% CI= -0.45, -0.09, p=0.003). There was a lack of policy-relevant associations between the pre-existing food environment and the current density of food outlet types, including supermarkets. Socioeconomically disadvantaged and minority populations may attract "unhealthy" food outlets over time. To support equal access to healthy food outlets, the availability of "less healthy" food outlets types may be relatively more important than the potential lack of supermarkets or full-service restaurants. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  13. A search for space energy alternatives

    Science.gov (United States)

    Gilbreath, W. P.; Billman, K. W.

    1978-01-01

    This paper takes a look at a number of schemes for converting radiant energy in space to useful energy for man. These schemes are possible alternatives to the currently most studied solar power satellite concept. Possible primary collection and conversion devices discussed include the space particle flux devices, solar windmills, photovoltaic devices, photochemical cells, photoemissive converters, heat engines, dielectric energy conversion, electrostatic generators, plasma solar collectors, and thermionic schemes. Transmission devices reviewed include lasers and masers.

  14. Study on partial overheat of the isolated phase busbar outlet box in Qinshan NPP phase Ⅱ

    International Nuclear Information System (INIS)

    Tang Fangxuan; Zhang Jian; Zeng Limin; Bao Yanxing; Zhang Lie; Yang Yuemin

    2013-01-01

    This paper recommended the structure of the isolated phase busbar outlet box installed in Qinshan II. The study on partial overheat of the outlet box shows that the ultimate causes are the loss of concentrated eddy current and short of cooling. So the improvement principles of 'distributing eddy current, cutting off inductive circle current and strengthening of ventilation' were determined. A new structure test outlet box was designed and manufactured, and the temperature rising experiment was carried out. Some alterations were made in the new structure outlet box, e.g. isolating materials were added between side plates of the upper outlet box, and also between the upper and lower outlet box. Two cooling blowers were added to the upper outlet box. After putting into operation, the hot-spot temperature of the new outlet box was greatly lowered down. Thus the operation environment was improved, and the operation safety ensured. It can be useful references for analyzing and dealing with similar problems. (authors)

  15. Spatial accessibility to physical activity facilities and to food outlets and overweight in French youth.

    Science.gov (United States)

    Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C

    2012-07-01

    Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio

  16. Coolant mixing in the LMFBR outlet plenum

    International Nuclear Information System (INIS)

    Chen, Y.B.; Golay, M.W.

    1977-06-01

    Small scale experiments involving water flows are used to provide mean flow and turbulence field data for LMFBR outlet plenum flows. Measurements are performed at Reynolds Number (Re) values of 33000 and 70000 in a 1/15-scale FFTF geometry and at Re = 35000 in a 3/80-scale CRBR geometry. The experimental behavior is predicted using two different turbulence model computer programs, TEACH-T and VARR-II. It is found that the qualitative nature of the flow field within the plenum depends strongly upon the distribution of the mean inlet velocity field, upon the degree of inlet turbulence, and upon the turbulence momentum exchange model used in the calculations. It is found in the FFTF geometry that the TEACH-T predictions are better than that of VARR-II, and in the CRBR geometry neither code provides a good prediction of the observed behavior. From the sensitivity analysis, it is found that the production and dissipation of turbulence are the dominant terms in the transport equations for turbulent kinetic energy and turbulent energy dissipation rate, and the diffusion terms are relatively small. From the same study a new set of empirical constants for the turbulence model is evolved for the prediction of plenum flows

  17. The prospects of making small retail outlets in the Townships aggressively competitive

    Directory of Open Access Journals (Sweden)

    Malefane Johannes Lebusa

    2013-12-01

    Full Text Available Historically, township Small Retail Outlets were mostly established for survival and operated under a generally closed market system where the competition was not very strong. However, with the advent of democracy many people lost their formal income through retrenchments and out of desperation, many of these people opened Small Retail Outlets thus most of the existing and new entrants into the township market were unskilled or semiskilled labourers with little or no formal skills in business or entrepreneurship. Such efforts were rarely guided by any specific and informed strategy of identifying and exploiting a gap in the market. With the consolidation of the free market system under democracy, big brand businesses such as Shoprite Checkers and Small Retail Outlets of foreign nationals with different strategies entered and competed in this township market. With fewer formal skills in business and entrepreneurship, the owners of the Small Retail Outlets struggled to compete and thrive under these relatively new economic conditions. Given this situation, I conducted semi-structured interviews with fifteen of these traditional Small Retail Outlets to find out and better understand the challenges they face and the skills that might be needed to aggressively compete in this space. Based on these findings and understandings, I further examined these issues and suggest infusions of specific entrepreneurship skills that could develop their aggressive competitiveness. Keywords: entrepreneurship, competitiveness, small retail outlets, shopping complexes, innovation

  18. Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler

    Science.gov (United States)

    Ghosh, D.; Ray, S.; Mandal, A.; Roy, H.

    2015-04-01

    This paper highlights a case study of typical premature failure of a radiant platen superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement and chemical analysis, are conducted as part of the investigations. Apart from these, metallographic analysis and fractography are also conducted to ascertain the probable cause of failure. Finally it has been concluded that the premature failure of the super heater tube can be attributed to localized creep at high temperature. The corrective actions has also been suggested to avoid this type of failure in near future.

  19. The association of alcohol outlet density with illegal underage adolescent purchasing of alcohol.

    Science.gov (United States)

    Rowland, Bosco; Toumbourou, John W; Livingston, Michael

    2015-02-01

    Although previous studies have suggested that greater community densities of alcohol sales outlets are associated with greater alcohol use and problems, the mechanisms are unclear. The present study examined whether density was associated with increased purchasing of alcohol by adolescents younger than the legal purchase age of 18 in Australia. The number of alcohol outlets per 10,000 population was identified within geographic regions in Victoria, Australia. A state-representative student survey (N = 10,143) identified adolescent reports of purchasing alcohol, and multilevel modeling was then used to predict the effects for different densities of outlet types (packaged, club, on-premise, general, and overall). Each extra sales outlet per 10,000 population was associated with a significant increase in the risk of underage adolescent purchasing. The strongest effect was for club density (odds ratio = 1.22) and packaged (takeaway) outlet density (odds ratio = 1.12). Males, older children, smokers, and those with substance-using friends were more likely to purchase alcohol. One mechanism by which alcohol sales outlet density may influence population rates of alcohol use and related problems is through increasing the illegal underage purchasing of alcohol. Copyright © 2015 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  20. 16 CFR Appendix B to Part 436 - Sample Item 20(1) Table-Systemwide Outlet Summary

    Science.gov (United States)

    2010-01-01

    ... DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. B Appendix B to Part 436—Sample... 1Outlet Type Column 2Year Column 3Outlets at the Start of the Year Column 4Outlets at the End of the Year...

  1. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    OpenAIRE

    Grygorenko Tetyana M.

    2016-01-01

    Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which ...

  2. Thermal indoor environment and energy consumption in a plus-energy house: cooling season measurements

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Olesen, Bjarne W.

    2015-01-01

    indoor environment. For the energy consumption of the HVAC system, air-to-brine heat pump, mixing station and controller of the radiant floor, and the air handling unit were considered. The measurements were analyzed based on the achieved indoor environment category (according to EN 15251...... the floor cooling system) and increasing the ventilation rate provided a better thermal indoor environment but with increased energy consumption. The thermal indoor environment and energy performance of the house can be improved with decreased glazing area, increased thermal mass, installation of solar...

  3. Radiative heat exchange of a meteor body in the approximation of radiant heat conduction

    International Nuclear Information System (INIS)

    Pilyugin, N.N.; Chernova, T.A.

    1986-01-01

    The problem of the thermal and dynamic destruction of large meteor bodies moving in planetary atmospheres is fundamental for the clarification of optical observations and anomalous phenomena in the atmosphere, the determination of the physicochemical properties of meteoroids, and the explanation of the fall of remnants of large meteorites. Therefore, it is important to calculate the coefficient of radiant heat exchange (which is the determining factor under these conditions) for large meteor bodies as they move with hypersonic velocities in an atmosphere. The solution of this problem enables one to find the ablation of a meteorite during its aerodynamic heating and to determine the initial conditions for the solution of problems of the breakup of large bodies and their subsequent motion and ablation. Hypersonic flow of an inviscid gas stream over an axisymmetric blunt body is analyzed with allowance for radiative transfer in a thick-thin approximation. The gas-dynamic problem of the flow of an optically thick gas over a large body is solved by the method of asymptotic joined expansions, using a hypersonic approximation and local self-similarity. An equation is obtained for the coefficient of radiant heat exchange and the peculiarities of such heat exchange for meteor bodies of large size are noted

  4. Sigmund Freud: pioneer in energy healing.

    Science.gov (United States)

    Edwards, Stephen D; Edwards, David J

    2010-02-01

    Energy healing is a popular contemporary term for forms of healing that facilitate a natural healing process through harmonizing, rebalancing, and releasing energy flow disturbed or blocked by disease and illness. Biographical evidence indicates that Freud used physical, suggestive, and radiant forms of energy healing, and that his personal life, metapsychology, and psychoanalysis were founded on dynamic, energetic experiences and conceptualizations. Analysis of Freud's life and work leads to the conclusion that in experience, theory, and practice, Freud typified the traditional role of therapist and was a pioneer in modern forms of energy healing.

  5. The Super-Radiant Mechanism and the Widths of Compound Nuclear States

    International Nuclear Information System (INIS)

    Auerbach, N

    2012-01-01

    In the introduction I will present the theory of the super-radiant mechanism as applied to various phenomena. I will then discuss the statistics of resonance widths in a many-body Fermi system with open decay channels. Depending on the strength of the coupling to the continuum such systems show deviations from the standard Porter-Thomas distribution. The deviations result from the process of increasing interaction of the intrinsic states through the common decay channels. In the limit of very strong coupling this leads to super-radiance. The results I will present are important for the understanding of recent experimental data concerning the width distribution of compound neutron resonances in nuclei.

  6. Validation of commercial business lists as a proxy for licensed alcohol outlets.

    Science.gov (United States)

    Carlos, Heather A; Gabrielli, Joy; Sargent, James D

    2017-05-19

    Studies of retail alcohol outlets are restricted to regions due to lack of U.S. national data. Commercial business lists (BL) offer a possible solution, but no data exists to determine if BLs could serve as an adequate proxy for license data. This paper compares geospatial measures of alcohol outlets derived from a commercial BL with license data for a large US state. We validated BL data as a measure of off-premise alcohol outlet density and proximity compared to license data for 5528 randomly selected California residential addresses. We calculated three proximity measures (Euclidean distance, road network travel time and distance) and two density measures (kernel density estimation and the count within a 2-mile radius) for each dataset. The data was acquired in 2015 and processed and analyzed in 2015 and 2016. Correlations and reliabilities between density (correlation 0.98; Cronbach's α 0.97-0.99) and proximity (correlations 0.77-0.86; α 0.87-0.92) measures were high. For proximity, BL data matched license in 55-57% of addresses, overstated distance in 19%, and understated in 24-26%. BL data can serve as a reliable proxy for licensed alcohol outlets, thus extending the work that can be performed in studies on associations between retail alcohol outlets and drinking outcomes.

  7. Bursting Events in Pressure Flushing with Expanding Bottom Outlet Channel within Dam Reservoir

    Directory of Open Access Journals (Sweden)

    soheila Tofighi

    2017-01-01

    Full Text Available Introduction: Currently, large dams in the world, due to the high amount of sediments in the reservoir, especially around the intake, have operational problems. One of the solutions for this problem is pressure flushing. In this type of flushing, a mixture of water and sediment is removed from bottom outlets form dam reservoir and a funnel shaped crater is created in the vicinity of the outlet opening. In laboratory experiments carried out in this study, pressure flushing with the expansion of bottom outlet within the reservoir and its statistical analysis of bursting events were investigated. The structure of the turbulent flow is not fully understood due to their complexity and random nature. Klein et al. Introduced the turbulence bursting in this kind of flow and Nezo and Nakagora suggested that the events resulting from turbulence bursting has a significant effect of transferring the sediment particles. Materials and Methods: For the purposes of this study, the experiments were conducted with a physical model with 7m length, 1.4m width, and 1.5m height, consisting of three parts namely the inlet of the model, the main reservoir, and settling basin. The main reservoir of the model was 5m long and the sediments were placed within this part of the model. The sediment particles were non-cohesive silica with uniform size and with median diameter (d50 1.15mm and geometrics standard deviation (σg 1.37. Experiments carried out with different discharges and water depths above the bottom outlet in different expansion size of outlet channel in constant sediment level of 20cm above the center of the outlet channel. The model was slowly filled with water until the water surface elevation reached to a desired level. The bottom outlet was manually opened, after a while sedimentwere discharged with the water flow in very high concentrations through the outlet channel (sudden discharge and a funnel shaped crater was formed in front of it. After the run of

  8. Methods of total spectral radiant flux realization at VNIIOFI

    Science.gov (United States)

    Ivashin, Evgeniy; Lalek, Jan; Rybczyński, Andrzej; Ogarev, Sergey; Khlevnoy, Boris; Dobroserdov, Dmitry; Sapritsky, Victor

    2018-02-01

    VNIIOFI carries out works on realization of independent methods for realization of the total spectral radiant flux (TSRF) of incoherent optical radiation sources - reference high-temperature blackbodies (BB), halogen lamps, and LED with quasi-Lambert spatial distribution of radiance. The paper describes three schemes for measuring facilities using photometers, spectroradiometers and computer-controlled high class goniometer. The paper describes different approaches for TSRF realization at the VNIIOFI National radiometric standard on the basis of high-temperature BB and LED sources, and gonio-spectroradiometer. Further, they are planned to be compared, and the use of fixed-point cells (in particular, based on the high-temperature δ(MoC)-C metal-carbon eutectic with a phase transition temperature of 2583 °C corresponding to the metrological optical “source-A”) as an option instead of the BB is considered in order to enhance calibration accuracy.

  9. The “School Foodshed”: schools and fast-food outlets in a London borough

    OpenAIRE

    Caraher, M.; Lloyd, S.; Madelin, T.

    2014-01-01

    Purpose – The purpose of this paper is to explore the location of fast-food outlets around secondary schools and the influence of fast-food availability on the food choices of school children in an inner-London borough. \\ud \\ud Design/methodology/approach – A number of methods including: mapping of outlets relative to schools; sampling food; gathering data on secondary school food policies; observing food behaviour in fast food outlets and focus groups with young people. Findings were fed bac...

  10. Submersible energy storage apparatus

    International Nuclear Information System (INIS)

    Mccartney, J.F.; Rowe, R.A.

    1980-01-01

    A submersible energy storage apparatus for an electrical power source is provided which includes an electrolysis unit feed water gas collection assembly and a fuel cell. The electrolysis unit feed water gas collection assembly includes a hydrogen container and an oxygen container wherein each container has a gas outlet and is capable of containing feed water as well as hydrogen and oxygen gases respectively. An electrolysis cell is provided which has a hydrogen outlet, an oxygen outlet and a feed water inlet. The hydrogen outlet is located in the hydrogen container, the oxygen outlet is located in the oxygen container, and the feed water inlet is located in one of the containers. Each of the containers has an opening to the submersible environment so as to be pressure responsive thereto. A barrier device is provided in association with the opening in each container for isolating the feed water in the container from water in the submersible environment. The fuel cell is operatively connected to the hydrogen and oxygen containers, and the electrical power source is operatively connected to the electrolysis cell. With this arrangement the electrolysis cell is capable of utilizing power from the power source during low electrical energy demand, and the fuel cell is capable of utilizing the hydrogen and oxygen gases for generating electricity during high demand periods

  11. Effects of radiant exposure and wavelength spectrum of light-curing units on chemical and physical properties of resin cements

    Directory of Open Access Journals (Sweden)

    Adriano Fonseca Lima

    2016-11-01

    Full Text Available Objectives In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs on the degree of conversion (DC and the mechanical properties of resin cements. Materials and Methods Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG, according to the different radiant exposures (5, 10, and 20 J/cm2 and two LCUs (single-peak and polywave. The specimens were made (7 mm in length × 2 mm in width × 1 mm in height using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA and post hoc Tukey's test were performed. Results No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.

  12. Proximity to Fast-Food Outlets and Supermarkets as Predictors of Fast-Food Dining Frequency.

    Science.gov (United States)

    Athens, Jessica K; Duncan, Dustin T; Elbel, Brian

    2016-08-01

    This study used cross-sectional data to test the independent relationship of proximity to chain fast-food outlets and proximity to full-service supermarkets on the frequency of mealtime dining at fast-food outlets in two major urban areas, using three approaches to define access. Interactions between presence of a supermarket and presence of fast-food outlets as predictors of fast-food dining were also tested. Residential intersections for respondents in point-of-purchase and random-digit-dial telephone surveys of adults in Philadelphia, PA, and Baltimore, MD, were geocoded. The count of fast-food outlets and supermarkets within quarter-mile, half-mile, and 1-mile street network buffers around each respondent's intersection was calculated, as well as distance to the nearest fast-food outlet and supermarket. These variables were regressed on weekly fast-food dining frequency to determine whether proximity to fast food and supermarkets had independent and joint effects on fast-food dining. The effect of access to supermarkets and chain fast-food outlets varied by study population. Among telephone survey respondents, supermarket access was the only significant predictor of fast-food dining frequency. Point-of-purchase respondents were generally unaffected by proximity to either supermarkets or fast-food outlets. However, ≥1 fast-food outlet within a 1-mile buffer was an independent predictor of consuming more fast-food meals among point-of-purchase respondents. At the quarter-mile distance, ≥1 supermarket was predictive of fewer fast-food meals. Supermarket access was associated with less fast-food dining among telephone respondents, whereas access to fast-food outlets were associated with more fast-food visits among survey respondents identified at point-of-purchase. This study adds to the existing literature on geographic determinants of fast-food dining behavior among urban adults in the general population and those who regularly consume fast food. Copyright

  13. Endoscopic stenting versus operative gastrojejunostomy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Chandrasegaram, Manju D; Eslick, Guy D; Mansfield, Clare O; Liem, Han; Richardson, Mark; Ahmed, Sulman; Cox, Michael R

    2012-02-01

    Malignant gastric outlet obstruction represents a terminal stage in pancreatic cancer. Between 5% and 25% of patients with pancreatic cancer ultimately experience malignant gastric outlet obstruction. The aim in palliating patients with malignant gastric outlet obstruction is to reestablish an oral intake by restoring gastrointestinal continuity. This ultimately improves their quality of life in the advanced stages of cancer. The main drawback to operative bypass is the high incidence of delayed gastric emptying, particularly in this group of patients with symptomatic obstruction. This study aimed to compare surgical gastrojejunostomy and endoscopic stenting in palliation of malignant gastric outlet obstruction, acknowledging the diversity and heterogeneity of patients with this presentation. This retrospective study investigated patients treated for malignant gastric outlet obstruction from December 1998 to November 2008 at Nepean Hospital, Sydney, Australia. Endoscopic duodenal stenting was performed under fluoroscopic guidance for placement of the stent. The operative patients underwent open surgical gastrojejunostomy. The outcomes assessed included time to diet, hospital length of stay (LOS), biliary drainage procedures, morbidity, and mortality. Of the 45 participants in this study, 26 underwent duodenal stenting and 19 had operative bypass. Comparing the stenting and operative patients, the median time to fluid intake was respectively 0 vs. 7 days (P < 0.001), and the time to intake of solids was 2 vs. 9 days (P = 0.004). The median total LOS was shorter in the stenting group (11 vs. 25 days; P < 0.001), as was the median postprocedure LOS (5 vs. 10 days; P = 0.07). Endoscopic stenting is preferable to operative gastrojejunostomy in terms of shorter LOS, faster return to fluids and solids, and reduced morbidity and in-hospital mortality for patients with a limited life span.

  14. Contamination of faecal coliforms in ice cubes sampled from food outlets in Kubang Kerian, Kelantan.

    Science.gov (United States)

    Noor Izani, N J; Zulaikha, A R; Mohamad Noor, M R; Amri, M A; Mahat, N A

    2012-03-01

    The use of ice cubes in beverages is common among patrons of food outlets in Malaysia although its safety for human consumption remains unclear. Hence, this study was designed to determine the presence of faecal coliforms and several useful water physicochemical parameters viz. free residual chlorine concentration, turbidity and pH in ice cubes from 30 randomly selected food outlets in Kubang Kerian, Kelantan. Faecal coliforms were found in ice cubes in 16 (53%) food outlets ranging between 1 CFU/100mL to >50 CFU/ 100mL, while in the remaining 14 (47%) food outlets, in samples of tap water as well as in commercially bottled drinking water, faecal coliforms were not detected. The highest faecal coliform counts of >50 CFU/100mL were observed in 3 (10%) food outlets followed by 11-50 CFU/100mL and 1-10 CFU/100mL in 7 (23%) and 6 (20%) food outlets, respectively. All samples recorded low free residual chlorine concentration (contamination by faecal coliforms was not detected in 47% of the samples, tap water and commercially bottled drinking water, it was concluded that (1) contamination by faecal coliforms may occur due to improper handling of ice cubes at the food outlets or (2) they may not be the water sources used for making ice cubes. Since low free residual chlorine concentrations were observed (food outlets, including that of ice cube is crucial in ensuring better food and water for human consumption.

  15. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    International Nuclear Information System (INIS)

    Camenzuli, Michelle; Terry, Jessica M.; Shalliker, R. Andrew; Conlan, Xavier A.; Barnett, Neil W.; Francis, Paul S.

    2013-01-01

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered

  16. Parallel segmented outlet flow high performance liquid chromatography with multiplexed detection

    Energy Technology Data Exchange (ETDEWEB)

    Camenzuli, Michelle [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Terry, Jessica M. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Shalliker, R. Andrew, E-mail: r.shalliker@uws.edu.au [Australian Centre for Research on Separation Science (ACROSS), School of Science and Health, University of Western Sydney (Parramatta), Sydney, NSW (Australia); Conlan, Xavier A.; Barnett, Neil W. [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia); Francis, Paul S., E-mail: paul.francis@deakin.edu.au [Centre for Chemistry and Biotechnology, School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3216 (Australia)

    2013-11-25

    Graphical abstract: -- Highlights: •Multiplexed detection for liquid chromatography. •‘Parallel segmented outlet flow’ distributes inner and outer portions of the analyte zone. •Three detectors were used simultaneously for the determination of opiate alkaloids. -- Abstract: We describe a new approach to multiplex detection for HPLC, exploiting parallel segmented outlet flow – a new column technology that provides pressure-regulated control of eluate flow through multiple outlet channels, which minimises the additional dead volume associated with conventional post-column flow splitting. Using three detectors: one UV-absorbance and two chemiluminescence systems (tris(2,2′-bipyridine)ruthenium(III) and permanganate), we examine the relative responses for six opium poppy (Papaver somniferum) alkaloids under conventional and multiplexed conditions, where approximately 30% of the eluate was distributed to each detector and the remaining solution directed to a collection vessel. The parallel segmented outlet flow mode of operation offers advantages in terms of solvent consumption, waste generation, total analysis time and solute band volume when applying multiple detectors to HPLC, but the manner in which each detection system is influenced by changes in solute concentration and solution flow rates must be carefully considered.

  17. Tobacco outlet density and tobacco knowledge, beliefs, purchasing behaviours and price among adolescents in Scotland.

    Science.gov (United States)

    Tunstall, Helena; Shortt, Niamh K; Niedzwiedz, Claire L; Richardson, Elizabeth A; Mitchell, Richard J; Pearce, Jamie R

    2018-06-01

    Despite long-term falls in global adult smoking prevalence and over 50 years of tobacco control policies, adolescent smoking persists. Research suggests greater densities of tobacco retail outlets in residential neighbourhoods are associated with higher adolescent smoking rates. Policies to reduce retail outlets have therefore been identified by public health researchers as a potential 'new frontier' in tobacco control. Better understanding of the pathways linking density of tobacco retailers and smoking behaviour could support these policies. In this study we use path analysis to assess how outlet density in the home environment is related to adolescent tobacco knowledge, beliefs, retail purchases and price in Scotland. We assessed 22,049 13 and 15 year old respondents to the nationally representative cross-sectional 2010 Scottish School Adolescent Lifestyle and Substance Use Survey. Outlet density was based on Scottish Tobacco Retailers Register, 2012, data. A spatially-weighted Kernel Density Estimation measure of outlet density within 400 m of respondents' home postcode was grouped into tertiles. The analysis considered whether outlet density was associated with the number of cigarette brands adolescents could name, positive beliefs about smoking, whether smokers purchased cigarettes from shops themselves or through adult proxies and perceived cost of cigarettes. Models were stratified by adolescent smoking status. The path analyses indicated that outlet density was not associated with most outcomes, but small, significant direct effects on knowledge of cigarette brands among those who had never smoked were observed. With each increase in outlet density tertile the mean number of brands adolescents could name rose by 0.07 (mean = 1.60; SD = 1.18; range = 4). This suggests greater outlet densities may have affected adolescents' knowledge of cigarette brands but did not encourage positive attitudes to smoking, purchases from shops or lower cigarette

  18. Means of increasing efficiency of CPC solar energy collector

    Science.gov (United States)

    Chao, B.T.; Rabl, A.

    1975-06-27

    A device is provided for improving the thermal efficiency of a cylindrical radiant energy collector. A channel is placed next to and in close proximity to the nonreflective side of an energy reflective wall of a cylindrical collector. A coolant is piped through the channel and removes a portion of the nonreflective energy incident on the wall which is absorbed by the wall. The energy transferred to the coolant may be utilized in a useful manner.

  19. Remaining Life Estimation Of Secondary Superheater Outlet On Industrial Electrical Boiler

    International Nuclear Information System (INIS)

    Soedardjo; Andryansyah; Arhatari, B.D.; Natsir, Muhammad; Triyadi, Ari; Farokhi

    2001-01-01

    Remaining life estimation of secondary superheater header outlet (SSHO) on industrial electrical boiler has been carried out. Estimation conducted by the observation of microstructure cavitation development based on Neubauer and Wedel theory. The result is available for isolated cavitation development present yet. That Secondary Superheater Outlet component is in good condition after 14 years operated and predicted could be operated for 36 years again

  20. Radiant heat transfer during the natural evaporation from free surfaces exposed to solar radiation; Transferencia de calor radiante durante a evaporacao natural em superficies livres expostas a radiacao solar

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, C O.M. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia; Hackenberg, C M [Universidade Federal do Rio de Janeiro, RJ (Brazil). Escola de Quimica

    1985-12-31

    In this work a conductive-convective-radiant model which includes phase change behavior, is developed in order to determine the rate of evaporation from free surface exposed to solar radiation and consequently the most important parameters, and their effects, on the design of salt solutions concentrating natural evaporation reservoirs may be analysed. The numerical solutions of the resulting of system of equations are shown to represent very well the experimental results measured on evaporation chambers specially built for daily operations. The thermal effect of spectrally selective surfaces as coating agents for the reservoir is also analysed. (author). 11 refs., 8 figs

  1. Effect of radiant heat at the birth site in farrowing crates on hypothermia and behaviour in neonatal piglets

    DEFF Research Database (Denmark)

    Andersen, Heidi Mai-Lis; Pedersen, Lene Juul

    2016-01-01

    It has been documented that floor heating of the farrowing area in loose housed sows improves survival of piglets significantly. However, today, the majority of farrowing pens are designed with crating of sows and slatted floor at the birth site. The aim of this study was to investigate whether...... providing radiant heat at the birth site to new-born piglets in pens with crated sows reduced hypothermia, time to first milk intake and growth of the piglets during the 1st week. Second parity Danish Landrace×Yorkshire sows (n=36) were randomly divided into two groups: Control (CG) and heat (HG......). In the area behind the sow (zone 1), two radiant heat panels were mounted above the slatted floor in the HG. The farrowings were attended, and the heaters were turned on at birth of first piglet and turned off 12 h after. Birth time, time to leave zone 1, time to first contact with udder and time to first...

  2. 16 CFR Appendix E to Part 436 - Sample Item 20(4) Table-Status of Company-Owned Outlets

    Science.gov (United States)

    2010-01-01

    ... RULES DISCLOSURE REQUIREMENTS AND PROHIBITIONS CONCERNING FRANCHISING Pt. 436, App. E Appendix E to Part... 5Outlets Reacquired From Franchisees Column 6Outlets Closed Column 7Outlets Sold to Franchisees Column...

  3. The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.

    Science.gov (United States)

    Fraser, Lorna K; Edwards, Kimberley L

    2010-11-01

    To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (pfood outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Comparison of radiant and convective cooling of office room: effect of workstation layout

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Rezgals, Lauris

    2014-01-01

    and compared. The room was furnished with two workstations, two laptops and two thermal manikins resembling occupants. Two heat load levels, design (65 W/m2) and usual (39 W/m2), were generated by adding heat from warm panels simulating solar radiation. Two set-ups were studied: occupants sitting......The impact of heat source location (room layout) on the thermal environment generated in a double office room with four cooling ventilation systems - overhead ventilation, chilled ceiling with overhead ventilation, active chilled beam and active chilled beam with radiant panels was measured...

  5. From Medical to Recreational Marijuana Sales: Marijuana Outlets and Crime in an Era of Changing Marijuana Legislation.

    Science.gov (United States)

    Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J

    2017-06-01

    A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.

  6. Velocities of antarctic outlet glaciers determined from sequential Landsat images

    Science.gov (United States)

    MacDonald, Thomas R.; Ferrigno, Jane G.; Williams, Richard S.; Lucchitta, Baerbel K.

    1989-01-01

    Approximately 91.0 percent of the volume of present-day glacier ice on Earth is in Antarctica; Greenland contains about another 8.3 percent of the volume. Thus, together, these two great ice sheets account for an estimated 99.3 percent of the total. Long-term changes in the volume of glacier ice on our planet are the result of global climate change. Because of the relationship of global ice volume to sea level (± 330 cubic kilometers of glacier ice equals ± 1 millimeter sea level), changes in the mass balance of the antarctic ice sheet are of particular importance.Whether the mass balance of the east and west antarctic ice sheets is positive or negative is not known. Estimates of mass input by total annual precipitation for the continent have been made from scattered meteorological observations (Swithinbank 1985). The magnitude of annual ablation of the ice sheet from calving of outlet glaciers and ice shelves is also not well known. Although the velocities of outlet glaciers can be determined from field measurements during the austral summer,the technique is costly, does not cover a complete annual cycle,and has been applied to just a few glaciers. To increase the number of outlet glaciers in Antarctica for which velocities have been determined and to provide additional data for under-standing the dynamics of the antarctic ice sheets and their response to global climate change, sequential Landsat image of several outlet glaciers were measured.

  7. KORELASI PENGGUNAAN BAHASA INGGRIS DALAM PENAMAAN FACTORY OUTLET (FO DI BANDUNG TERHADAP KEPUTUSAN PEMBELIAN

    Directory of Open Access Journals (Sweden)

    Gartika Rahmasari

    2016-03-01

        Abstrak - Bahasa Inggris merupakan bahasa yang memiliki prestise atau kedudukan yang tinggi, bahkan di Indonesia yang memiliki bahasa Indonesia sebagai bahasa nasional. Bahasa Inggris sebagai bahasa internasional mendapatkan apresiasi lebih tinggi dibandingkan dengan bahasa Indonesia, khususnya di bidang pariwisata. Bandung sebagai salah satu tujuan pariwisata, khususnya wisata kuliner dan tujuan belanja, tidak terkecuali mendapat pengaruh yang besar dalam hal penggunaan bahasa Inggris. Hal ini dapat dilihat dari penggunaan sejumlah nama Factory Outlet yang ada di Bandung, yang hampir sebagian besar menggunakan bahasa Ingris atau serapan bahasa Inggris sebagai “brand” atau nama yang digunakan oleh Factory Outlet yang tersebar di seluruh Bandung. Jurnal ini merupakan study literatur yang meneliti tentang hubungan penggunaan bahasa Asing dalam nama Factory Outlet  (FO terhadap keputusan pembelian. Yang menjadi responden yang diteliti dalam penelitian ini adalah mahasiswa Ilmu Komunikasi, Universitas Telkom sebanyak 55 responden, dengan rentang usia 17-20 tahun. Dari hasil penelitian, diketahui bahwa secara umum, penggunaan bahasa Inggris dalam penamaan Factory Outlet (FO mempengaruhi keputusan responden untuk berbelanja ke FO tersebut.   Kata Kunci: Keputusan Pembelian, Factory Outlet, FO, Bahasa Inggris.

  8. Proximity of off-premise alcohol outlets and heavy alcohol consumption: a cohort study.

    Science.gov (United States)

    Halonen, Jaana I; Kivimäki, Mika; Virtanen, Marianna; Pentti, Jaana; Subramanian, S V; Kawachi, Ichiro; Vahtera, Jussi

    2013-09-01

    Availability of alcohol has been associated with alcohol consumption in cross-sectional studies. We examined longitudinally whether change in proximity to off-premise (i.e., no consumption on the premises) beer and liquor outlets is associated with heavy alcohol consumption. Distances from 54,778 Finnish Public Sector study participants' homes to the nearest off-premise beer and liquor outlets were calculated using Global Positioning System-coordinates. Between-individual analyses were used to study the effects of distance to the nearest outlet on heavy alcohol use, and within-individual analyses to study the effects of a change in distance on change in heavy use. Mean follow-up time in 2000-2009 was 6.8 (standard deviation 2.0) years. In a between-individual analysis, decrease from ≥500 m to alcohol use in women (odds ratio 1.23, 95% CI 1.05-1.44), but not in men. In a within-individual analysis decrease from 500 m to 0m in log-transformed continuous distance to the nearest beer outlet increased the odds of heavy alcohol consumption in women by 13% (odds ratio 1.13, 95% CI 1.01-1.27). For the corresponding change in distance to liquor outlet the increase was 3% (odds ratio 1.03, 95% CI 0.97-1.09). Change in distance from home to the nearest off-premise alcohol outlet affects the risk of heavy alcohol consumption in women. This evidence supports policies that restrict physical availability of alcohol. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Neighborhood alcohol outlet density and genetic influences on alcohol use: evidence for gene-environment interaction.

    Science.gov (United States)

    Slutske, Wendy S; Deutsch, Arielle R; Piasecki, Thomas M

    2018-05-07

    Genetic influences on alcohol involvement are likely to vary as a function of the 'alcohol environment,' given that exposure to alcohol is a necessary precondition for genetic risk to be expressed. However, few gene-environment interaction studies of alcohol involvement have focused on characteristics of the community-level alcohol environment. The goal of this study was to examine whether living in a community with more alcohol outlets would facilitate the expression of the genetic propensity to drink in a genetically-informed national survey of United States young adults. The participants were 2434 18-26-year-old twin, full-, and half-sibling pairs from Wave III of the National Longitudinal Study of Adolescent to Adult Health. Participants completed in-home interviews in which alcohol use was assessed. Alcohol outlet densities were extracted from state-level liquor license databases aggregated at the census tract level to derive the density of outlets. There was evidence that the estimates of genetic and environmental influences on alcohol use varied as a function of the density of alcohol outlets in the community. For example, the heritability of the frequency of alcohol use for those residing in a neighborhood with ten or more outlets was 74% (95% confidence limits = 55-94%), compared with 16% (95% confidence limits = 0-34%) for those in a neighborhood with zero outlets. This moderating effect of alcohol outlet density was not explained by the state of residence, population density, or neighborhood sociodemographic characteristics. The results suggest that living in a neighborhood with many alcohol outlets may be especially high-risk for those individuals who are genetically predisposed to frequently drink.

  10. Effects of blue diode laser (445 nm) and LED (430-480 nm) radiant heat treatments on dental glass ionomer restoratives

    Science.gov (United States)

    Dionysopoulos, Dimitrios; Tolidis, Kosmas; Strakas, Dimitrios; Gerasimou, Paris; Sfeikos, Thrasyvoulos; Gutknecht, Norbert

    2018-02-01

    The purpose of this in vitro study was to evaluate the effect of two radiant heat treatments on water sorption, solubility and surface roughness of three conventional glass ionomer cements by using a blue diode laser (445 nm) and a light emitting diode (LED) unit (430-480 nm). Thirty disk-shaped specimens were prepared for each tested GIC (Equia Fil, Ketac Universal Aplicap and Riva Self Cure). The experimental groups (n = 10) of the study were as follows: Group 1 was the control group, in Group 2 the specimens were irradiated for 60 s at the top surface using a LED light-curing unit and in Group 3 the specimens were irradiated for 60 s at the top surface using a blue light diode laser. Statistical analysis was performed using one-way ANOVA and Tukey post hoc tests at a level of significance of a = 0.05. Radiant heat treatments with both laser and LED devices significantly decreased water sorption and solubility (p tested GICs. Blue diode laser treatment was seemed to be more effective compared to LED treatment for some of the tested materials. There were no changes in surface roughness of the GICs after the treatments (p > 0.05). Among the tested materials there were differences in water sorption and solubility (p 0.05). The use of the blue diode laser for this radiant heat treatment was harmless for the surface of the tested GICs and may be advantageous for the longevity of their restorations.

  11. Development of a solenoid actuated planar valveless micropump with single and multiple inlet-outlet arrangements

    Science.gov (United States)

    Kumar, N.; George, D.; Sajeesh, P.; Manivannan, P. V.; Sen, A. K.

    2016-07-01

    We report a planar solenoid actuated valveless micropump with multiple inlet-outlet configurations. The self-priming characteristics of the multiple inlet-multiple outlet micropump are studied. The filling dynamics of the micropump chamber during start-up and the effects of fluid viscosity, voltage and frequency on the dynamics are investigated. Numerical simulations for multiple inlet-multiple outlet micropumps are carried out using fluid structure algorithm. With DI water and at 5.0 Vp-p, 20 Hz frequency, the two inlet-two outlet micropump provides a maximum flow rate of 336 μl min-1 and maximum back pressure of 441 Pa. Performance characteristics of the two inlet-two outlet micropump are studied for aqueous fluids of different viscosity. Transport of biological cell lines and diluted blood samples are demonstrated; the flow rate-frequency characteristics are studied. Viability of cells during pumping with multiple inlet multiple outlet configuration is also studied in this work, which shows 100% of cells are viable. Application of the proposed micropump for simultaneous pumping, mixing and distribution of fluids is demonstrated. The proposed integrated, standalone and portable micropump is suitable for drug delivery, lab-on-chip and micro-total-analysis applications.

  12. Factors Influencing Demand for a Producer-Owned Beef Retail Outlet

    OpenAIRE

    Lusk, Jayson L.; Cevallos, Edgar

    2004-01-01

    As the farm-to-retail price spread continues to grow, come cattle producers a beginning to consider integrating into the retail sector. Such a venture would require large investments in capital with uncertain return. This study seeks to determine the potential success of a stand-alone retail outlet selling “all natural†beef in an affluent area of Jackson, MS. Using choice-based conjoint analysis, demand for the new retail outlet is modeled as a function of the beef price at the store, dis...

  13. Geocoding routinely collected administrative data to measure access to alcohol outlets in Wales

    Directory of Open Access Journals (Sweden)

    Richard Fry

    2017-04-01

    All authorities were able to provide an actual or approximate license issue date, allowing us to summarise the number of outlets annually. Several authorities were unable to provide precise outlet closure dates, so the date of the last interaction with the outlet was used to generate an approximate end date. One-half of the unitary authorities were able to provide the On/Off sales status of outlets, and 9 were able to provide opening hours. From these data we were able to geocode 53% (range 28% to 72% by local authority using GIS, the remaining 47% were matched using Google products to verify and extract a precise geographic location. Conclusions The collation and processing of retrospective alcohol outlet data was successfully completed to enable the building of a longitudinal exposure dataset. There was considerable variation between the unitary authorities in the quality of address data, and data related to the availability of alcohol, for example opening hours. The lack of address structure required us to devise a manual address matching process to capture the addresses that could not be geocoded. To aid future data linkage based evaluations to provide policy evidence in a timely manner, local government datasets should use standardised data fields, including addresses and Point-of-Capture address verification.

  14. Radiant Ceiling Panels Combined with Localized Methods for Improved Thermal Comfort of Both Patient and Medical Staff in Patient Room

    DEFF Research Database (Denmark)

    Mori, Sakura; Barova, Mariya; Bolashikov, Zhecho Dimitrov

    2012-01-01

    The objectives were to identify whether ceiling installed radiant heating panels can provide thermal comfort to the occupants in a patient room, and to determine a method for optimal thermal environment to both patient and medical staff simultaneously. The experiments were performed in a climate...... mattress were used to provide local heating for the patient. The effects of the methods were identified by comparing the manikin based equivalent temperatures. The optimal thermal comfort level for both patient and medical staff would obtained when two conventional cotton blankets were used with extra...... chamber resembling a single-bed patient room under convective air conditioning alone or combined with the ceiling installed radiant heating panels. Two thermal manikins simulated a patient lying in the bed and a doctor standing next to the patient. Conventional cotton blanket, electric blanket, electric...

  15. 7 CFR 993.108 - Non-human consumption outlet.

    Science.gov (United States)

    2010-01-01

    ... consumption outlet means any livestock feeder or manufacturer of inedible syrup, industrial alcohol, animal... FR 8278, Sept. 2, 1961; 26 FR 8483, Sept. 9, 1961] Effective Date Note: At 70 FR 30613, May 27, 2005...

  16. 16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...

  17. Gastric diverticulum causing gastric outlet obstruction in the setting of duodenal atresia

    Directory of Open Access Journals (Sweden)

    Devashis Mukherjee

    2018-04-01

    Full Text Available Duodenal obstruction due to duodenal atresia occurs in 1 in 10,000 live births and is the most common type of intestinal obstruction in neonates [1–3]. Gastric outlet obstruction in the newborn period from causes other than hypertrophic pyloric stenosis is very uncommon [3]. Potential etiologies include gastric volvulus, antral web, and duplication cysts. Gastric diverticula in the infant is even more rare, with only a few case reports published, and only one describes a gastric diverticulum in the presence of a duodenal atresia [4–8]. In this report, we describe the first case of a gastric outlet obstruction due to a gastric diverticulum in the presence of duodenal atresia. Keywords: Duodenal atresia, Gastric diverticulum, Gastric outlet obstruction

  18. Examining the interaction between food outlets and outdoor food advertisements with primary school food environments.

    Science.gov (United States)

    Walton, Mat; Pearce, Jamie; Day, Peter

    2009-09-01

    Schools are commonly seen as a site of intervention to improve children's nutrition, and prevent excess weight gain. Schools may have limited influence over children's diets; however, with home and community environments also exerting an influence within schools. This study considered the environment of food outlets and outdoor food advertisements surrounding four case study primary schools in New Zealand, and the impact of that external environment on within-school food environments. The shortest travel route between school and home addresses, and the number of food outlets and advertisements passed on that route, was calculated for each student. Interviews with school management were conducted. The schools with a higher percentage of students passing food outlets and advertisements considered that their presence impacted on efforts within schools to improve the food environment. Limiting students' exposure to food outlets and outdoor food adverts through travel route planning, reducing advertising, or limiting the location of food outlets surrounding schools could be explored as intervention options to support schools in promoting nutrition.

  19. Abandonment of the low level outlet structure at the McGregor South Dam

    Energy Technology Data Exchange (ETDEWEB)

    Mack, D.L; Murray, T.K. [Klohn-Crippen Consultants Ltd., Calgary, AB (Canada); Soutar, B.M. [Alberta Transportation, Edmonton, AB (Canada)

    2008-07-01

    The Carseland-Bow River Headworks (CBRH) is a major multi-purpose water delivery system, situated in southern Alberta. It supplies water to 87,000 hectares of agricultural land and several municipalities. The system was originally built starting in 1909. It consists of diversion works on the Bow River, 65 kilometres of canal, and the McGregor and Little Bow reservoirs. In the 1950s, the system was rehabilitated by the Prairie Farm Rehabilitation Administration (PFRA), and Travers Reservoir was added in 1954. In 1973, ownership and operation of the CBRH system was turned over to Alberta Environment. In 2001, Alberta Transportation implemented a major program to rehabilitate and upgrade the CBRH system. This program included increasing the capacity of the canals and structures, and upgrading the dams to meet current dam safety guidelines. The project involved raising the north and south dams, providing an auxiliary spillway to accommodate the probable maximum flood (PMF), and rehabilitating the existing reservoir inlet and low level outlet structures. This paper discussed the abandonment of the existing low level outlet structure located within the south dam. The paper discussed the existing dams and outlet structure as well as the south dam and outlet structure. The abandonment of the existing low level outlet structure was discussed in terms of general construction; demolition; upstream conduits and gatewell; and downstream conduit. Several illustrations and photographs of the dam and the demolition were presented. It was concluded that the in-place abandonment of the existing low level outlet structure at the McGregor South Dam provides significant advantages, including eliminating the need to construct and remove an extensive cofferdam within the reservoir. 6 refs., 2 tabs., 4 figs.

  20. Comparison of indoor air distribution and thermal environment for different combinations of radiant heating systems with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Fang, Lei; Olesen, Bjarne W.

    2018-01-01

    A hybrid system with a radiant heating system and a mechanical ventilation system, which is regarded as an advanced heating, ventilation and air-conditioning (HVAC) system, has been applied in many modern buildings worldwide. To date, almost no studies focused on comparative analysis of the indoor...... air distribution and the thermal environment for all combinations of radiant heating systems with mechanical ventilation systems. Therefore, in this article, the indoor air distribution and the thermal environment were comparatively analyzed in a room with floor heating (FH) or ceiling heating (CH......) and mixing ventilation (MV) or displacement ventilation (DV) when the supply air temperature ranged from 15.0°C to 19.0°C. The results showed that the temperature effectiveness values were 1.05–1.16 and 0.95–1.02 for MV+ FH and MV+ CH, respectively, and they were 0.78–0.91 and 0.51–0.67 for DV + FH and DV...

  1. Numerical prediction and performance experiment in a deep-well centrifugal pump with different impeller outlet width

    Science.gov (United States)

    Shi, Weidong; Zhou, Ling; Lu, Weigang; Pei, Bing; Lang, Tao

    2013-01-01

    The existing research of the deep-well centrifugal pump mainly focuses on reduce the manufacturing cost and improve the pump performance, and how to combine above two aspects together is the most difficult and important topic. In this study, the performances of the deep-well centrifugal pump with four different impeller outlet widths are studied by the numerical, theoretical and experimental methods in this paper. Two stages deep-well centrifugal pump equipped with different impellers are simulated employing the commercial CFD software to solve the Navier-Stokes equations for three-dimensional incompressible steady flow. The sensitivity analyses of the grid size and turbulence model have been performed to improve numerical accuracy. The flow field distributions are acquired and compared under the design operating conditions, including the static pressure, turbulence kinetic energy and velocity. The prototype is manufactured and tested to certify the numerical predicted performance. The numerical results of pump performance are higher than the test results, but their change trends have an acceptable agreement with each other. The performance results indicted that the oversize impeller outlet width leads to poor pump performances and increasing shaft power. Changing the performance of deep-well centrifugal pump by alter impeller outlet width is practicable and convenient, which is worth popularizing in the engineering application. The proposed research enhances the theoretical basis of pump design to improve the performance and reduce the manufacturing cost of deep-well centrifugal pump.

  2. Expiry of medicines in supply outlets in Uganda.

    Science.gov (United States)

    Nakyanzi, Josephine Katabaazi; Kitutu, Freddy Eric; Oria, Hussein; Kamba, Pakoyo Fadhiru

    2010-02-01

    The expiry of medicines in the supply chain is a serious threat to the already constrained access to medicines in developing countries. We investigated the extent of, and the main contributing factors to, expiry of medicines in medicine supply outlets in Kampala and Entebbe, Uganda. A cross-sectional survey of six public and 32 private medicine outlets was done using semi-structured questionnaires. The study area has 19 public medicine outlets (three non-profit wholesalers, 16 hospital stores/pharmacies), 123 private wholesale pharmacies and 173 retail pharmacies, equivalent to about 70% of the country's pharmaceutical businesses. Our findings indicate that medicines prone to expiry include those used for vertical programmes, donated medicines and those with a slow turnover. Awareness about the threat of expiry of medicines to the delivery of health services has increased. We have adapted training modules to emphasize management of medicine expiry for pharmacy students, pharmacists and other persons handling medicines. Our work has also generated more research interest on medicine expiry in Uganda. Even essential medicines expire in the supply chain in Uganda. Sound coordination is needed between public medicine wholesalers and their clients to harmonize procurement and consumption as well as with vertical programmes to prevent duplicate procurement. Additionally, national medicine regulatory authorities should enforce existing international guidelines to prevent dumping of donated medicine. Medicine selection and quantification should be matched with consumer tastes and prescribing habits. Lean supply and stock rotation should be considered.

  3. Numerical analysis of temperature fluctuation in core outlet region of China experimental fast reactor

    International Nuclear Information System (INIS)

    Zhu Huanjun; Xu Yijun

    2014-01-01

    The temperature fluctuation in core outlet region of China Experimental Fast Reactor (CEFR) was numerically simulated by the CFD software Star CCM+. With the core outlet temperatures, flows etc. under rated conditions given as boundary conditions, a 1/4 region model of the reactor core outlet region was established and calculated using LES method for this problem. The analysis results show that while CEFR operates under rated conditions, the temperature fluctuation in lower part of core outlet region is mainly concentrated in area over the edge components (steel components, control rod assembly), and one in upper part is remarkable in area above all the components. The largest fluctuation amplitude is 19 K and the remarkable frequency is below 5 Hz, and it belongs to typically low frequency fluctuation. The conclusion is useful for further experimental work. (authors)

  4. Results from radiant treatment in no Hodgkin's lymphomas of adults

    International Nuclear Information System (INIS)

    Alert, J.; Rodriguez, E.; Mesa, E.; Diaz, C.

    1982-01-01

    From 1973 to 1979, at the Institute of Oncology and Radiobiology, Havana City, 91 adults were irradiated because they underwent no Hodgkin's lymphomas at Stage I (located) and Stage II (regional extension) to whom radiant treatment was the basic therapeutic selection, with single or multiple fields and dose ranging between 3 500 and 4 000 rads-tumor, and some of them at Stage III, where primary treatment was chemotherapy. Present survival for all of them after 3 and 5 years is 55.7% and 54.7%, with 84.4% for patients at Stage I, 55.8% and 52.4% for Stage II and 33.8% for Stage III. Survival was similar for both sexes; in the same way ganglionar processes and those of extraganglionar localization presented no significant survival differences. Only to 7 patients (7.7%) modular forms were diagnosed. (author)

  5. Free of pollution gas - an utopia or attainable goal? Gas radiant burner with a small capacity

    International Nuclear Information System (INIS)

    Hofbauer, P.; Bornscheuer, W.

    1993-01-01

    The firm Viessmann has developed a gas radiant burner for boiler capacities up to 100 kN combusting gas with extremely low pollutant emissions. This is possible since from the reaction zone a considerable part of the combustion heat is delivered through radiation by means of a glowing special steel structure. The theoretical fundamentals are explained by means of considerations regarding the equilibrium and a reaction kinetic numerical model. (orig.) [de

  6. The roles of outlet density and norms in alcohol use disorder

    OpenAIRE

    Ahern, J; Balzer, L; Galea, S

    2015-01-01

    © 2015 Elsevier Ireland Ltd. Background: Alcohol outlet density and norms shape alcohol consumption. However, due to analytic challenges we do not know: (a) if alcohol outlet density and norms also shape alcohol use disorder, and (b) whether they act in combination to shape disorder. Methods: We applied a new targeted minimum loss-based estimator for rare outcomes (rTMLE) to a general population sample from New York City (N= 4000) to examine the separate and combined relations of neighborhood...

  7. Ayurvedic medicine in Mauritius: Profile of Ayurvedic outlet, use, sale, distribution, regulation and importation.

    Science.gov (United States)

    Elaheebocus, Naailah; Mahomoodally, M Fawzi

    2017-02-02

    Ayurvedic medicine (AM) is a legalised alternative traditional medical system in the multicultural tropical island of Mauritius. A panoply of Ayurvedic specialised shops/centres involved in the provision of Ayurvedic services hereafter termed as 'outlets' operates in different regions of the island and is extensively exploited by a significant number of Mauritians. Nonetheless, there is currently no study geared towards studying the status of AM and profile of Ayurvedic outlets in Mauritius and there is undoubtedly a dearth of standardized regulatory framework governing the practice of AM in Mauritius. The present study attempts to study the profile of Ayurvedic outlets, sale, distribution, regulation and importation of AM in Mauritius. To evaluate the characteristics profile of Ayurvedic shops/clinics/pharmacies/centres, to document common Ayurvedic products used in the treatment and management of diseases, and to analyse existing regulatory control of AM in Mauritius. Ayurvedic outlets were identified using a random approach. Once permission granted, outlets were visited where face-to-face interviews with Ayurvedic practitioners/directors/dispensers were undertaken using a semi-structured questionnaire. The characteristics of the outlets with respect to the type of business registration, procurement and dispensing of products, registration and qualification of personnels employed amongst others were studied. The International Classification of Diseases (ICD) 10 was used to classify common AM dispensed to patients. Additionally, information was sought from local authorities pertaining to existing legislation governing the importation and regulation of AM in Mauritius. A total of 16 Ayurvedic outlets ('pharmacies' (n=3), clinics (n=2), shops (n=5) and centres (n=6)) was surveyed. Six outlets dispensed AM strictly on prescription only after consultation with an onsite full-time employed registered Ayurvedic practitioner. Seven outlets offered AM both on prescription

  8. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Kedir, Abdu; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n=5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  9. Is proximity to alcohol outlets associated with alcohol consumption and alcohol-related harm in Denmark?

    DEFF Research Database (Denmark)

    Seid, Abdu K.; Berg-Beckhoff, Gabriele; Stock, Christiane

    2018-01-01

    Background: This study examined the associations between distance from residence to the nearest alcohol outlet with alcohol consumption as well as with alcohol-related harm. Methods: Data on alcohol consumption, alcohol-related harm and sociodemographics were obtained from the 2011 Danish Drug...... and Alcohol Survey (n = 5133) with respondents aged 15–79 years. The information on distances from residence to the nearest alcohol outlets was obtained from Statistics Denmark. Multiple logistic and linear regressions were used to examine the association between distances to outlets and alcohol consumption...... whereas alcohol-related harm was analysed using negative binomial regression. Results: Among women it was found that those living closer to alcohol outlets were more likely to report alcohol-related harm (p

  10. Modelling and Simulation of the Radiant Field in an Annular Heterogeneous Photoreactor Using a Four-Flux Model

    Directory of Open Access Journals (Sweden)

    O. Alvarado-Rolon

    2018-01-01

    Full Text Available This work focuses on modeling and simulating the absorption and scattering of radiation in a photocatalytic annular reactor. To achieve so, a model based on four fluxes (FFM of radiation in cylindrical coordinates to describe the radiant field is assessed. This model allows calculating the local volumetric rate energy absorption (LVREA profiles when the reaction space of the reactors is not a thin film. The obtained results were compared to radiation experimental data from other authors and with the results obtained by discrete ordinate method (DOM carried out with the Heat Transfer Module of Comsol Multiphysics® 4.4. The FFM showed a good agreement with the results of Monte Carlo method (MC and the six-flux model (SFM. Through this model, the LVREA is obtained, which is an important parameter to establish the reaction rate equation. In this study, the photocatalytic oxidation of benzyl alcohol to benzaldehyde was carried out, and the kinetic equation for this process was obtained. To perform the simulation, the commercial software COMSOL Multiphysics v. 4.4 was employed.

  11. The effects of radiant cooling versus convective cooling on human eye tear film stability and blinking rate

    DEFF Research Database (Denmark)

    Nygaard, Linette; Uth, Simon C.; Bolashikov, Zhecho Dimitrov

    2014-01-01

    The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation. The subj......The effect of indoor temperature, radiant and convective cooling on tear film stability and eye blink frequency was examined. 24 human subjects were exposed to the non-uniform environment generated by localised chilled beam and a chilled ceiling combined with overhead mixing ventilation....... The subjects participated in four two-hour experiments. The room air temperature was kept at 26 °C or 28 °C. Tear film samples were collected after 30 min of acclimatisation and at the end of the exposures. Eye blinking frequency was analysed for the first and last 15 min of each exposure. The tear film...... stability decreased as the temperature increased. The highest number of subjects with unchanged or improved tear film quality was observed with the localised chilled beam at 26 °C. A trend was found between subjects who reported eye irritation and had a bad tear film quality....

  12. Sensitivity analysis of the thermal performance of radiant and convective terminals for cooling buildings

    DEFF Research Database (Denmark)

    Le Dréau, J.; Heiselberg, P.

    2014-01-01

    Heating and cooling terminals can be classified in two main categories: convective terminals (e.g. active chilled beam, air conditioning) and radiant terminals. The mode of heat transfer of the two emitters is different: the first one is mainly based on convection, whereas the second one is based...... conducted to determine the parameters influencing their thermal performance the most. The air change rate, the outdoor temperature and the air temperature stratification have the largest effect on the cooling need (maintaining a constant operative temperature). For air change rates higher than 0.5 ACH...

  13. A CLINICAL STUDY ON GASTRIC OUTLET OBSTRUCTION IN A SOUTH INDIAN TEACHING HOSPITAL

    Directory of Open Access Journals (Sweden)

    Sailaja

    2015-10-01

    Full Text Available Gastric outlet obstruction is defined as a clinical and patho - physiological consequence of any disease process that produces a mechanical impediment to gastric emptying which may be extrinsic or intrinsic. Gastric outlet obstruction can be a diagnostic and treatment dilemma. Endoscopy of upper gastrointestinal tract has been a sensitive and specific investigation to study the status of gastric outlet - the pylorus and has enabled early detection of lesions of both stomach a nd duodenum. We undertook a prospective clinical study regarding incidence, etiology, investigation and management of cases of Gastric outlet obstruction in adults in a period of three years. In our study the m ost common cause of GOO is Carcinoma stomach a ntral region 46.6% , duodenal ulcer 33.3% , corrosive acid ingestion sequel 8.3%, peri ampullary carcinoma 6.6%, Ca pancreas 3.3%% , cholangio Carcinoma 1.6%. Males are more commonly involved in a ratio of M: F=3:1. Surgical procedures done varied from defini tive resections to palliative bypass or feeding jejunostomy for enteral feeding

  14. Is there an association between home-tobacco outlet proximity and smoking status in Denmark?

    DEFF Research Database (Denmark)

    Berg-Beckhoff, Gabriele; K Seid, Abdu; Stock, Christiane

    2017-01-01

    and/or tobacco outlets on smoking habits for the first time in a population based survey in Denmark. Method: Data came from the 2011 Danish national alcohol and drug survey of the Centre for Alcohol and Drug Research of Aarhus University (response rate 64%) and registries of Statistics Denmark were...... between residing close to a tobacco outlet and the prevalence of current and previous smoking. However, no significant association was found between distance from residence to tobacco outlets and smoking habits. Discussion: The prevalence of current smokers (24%) is in accordance with the 2011 annual......Abstract It is well established that exposure to point-of-sale tobacco promotion or impulse purchases and access to and distance to tobacco outlets are related to youth and adult smoking. The aim of the present study was to examine the association of distance from residence to the nearest alcohol...

  15. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.

    Science.gov (United States)

    Troussel, Ph; Villette, B; Emprin, B; Oudot, G; Tassin, V; Bridou, F; Delmotte, F; Krumrey, M

    2014-01-01

    CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

  16. Effects of inlet/outlet configurations on the electrostatic capture of airborne nanoparticles and viruses

    International Nuclear Information System (INIS)

    Jang, Jaesung; Akin, Demir; Bashir, Rashid

    2008-01-01

    Motivated by capture and detection of airborne biological agents in real time with a cantilever biosensor without introducing the agents into liquids, we present the effects of inlet/outlet configurations of a homemade particle collector on the electrostatic capture of airborne 100 nm diameter nanoparticles under swirling gas flows. This particle collector has three different inlet/outlet configurations: forward inlet/outlet (FO), backward inlet/outlet (BO) and straight inlet/outlet (SO) configurations. We also present the electrostatic capture of Vaccinia viruses using the same particle collector and compare these virus measurements with the nanoparticle cases. The most particles were collected in the FO configuration. The numbers of particles captured in the BO and SO configurations were close within their standard deviations. For all the three configurations tested, the number of particles captured in the center electrode C was much smaller than those captured in the other electrodes at a flow rate of 1.1 l min −1 and an applied potential of 2 kV. Using a commercial CFD code FLUENT, we also simulated the effects of the three inlet/outlet configurations on the particle capture in terms of particle trajectories, velocities and travel times. This simulation was in a good agreement with measurements that the FO configuration is the most favorable to particle capture among the tested configurations at a flow rate of 1.1 l min −1 . The effects of particle diameters on the capture will also be discussed. This collector can be used for real-time monitoring of bioaerosols along with cantilever biosensors

  17. Isolated Cervical Rib Fracture: A Rare Etiology of Thoracic Outlet Syndrome

    Directory of Open Access Journals (Sweden)

    Rayees Ahmad Dar

    2011-01-01

    Full Text Available Isolated fracture of a cervical rib is a very rare entity and usually presents as a painless swelling or as thoracic outlet syndrome. We describe a case of a 45-year-old woman with history of fall two months back. She presented with symptoms of neurogenic thoracic outlet syndrome for one month. Isolated left cervical rib fracture was documented on X-ray cervical spine. Her fractured cervical rib was resected through a supraclavicular approach, and symptoms resolved completely in the postoperative period.

  18. Supermarket and fast-food outlet exposure in Copenhagen: associations with socio-economic and demographic characteristics.

    Science.gov (United States)

    Svastisalee, Chalida M; Nordahl, Helene; Glümer, Charlotte; Holstein, Bjørn E; Powell, Lisa M; Due, Pernille

    2011-09-01

    To investigate whether exposure to fast-food outlets and supermarkets is socio-economically patterned in the city of Copenhagen. The study was based on a cross-sectional multivariate approach to examine the association between the number of fast-food outlets and supermarkets and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v. indicators of socio-economic status (percentage of recent immigrants, percentage without a high-school diploma, percentage of the population under 35 years of age and average household income in Euros) was performed using negative binomial analysis. Copenhagen, Denmark. The unit of analysis was neighbourhood (n 400). In the fully adjusted models, income was not a significant predictor for supermarket exposure. However, neighbourhoods with low and mid-low income were associated with significantly fewer fast-food outlets. Using backwise deletion from the fully adjusted models, low income remained significantly associated with fast-food outlet exposure (rate ratio = 0·66-0·80) in the final model. In the city of Copenhagen, there was no evidence of spatial patterning of supermarkets by income. However, we detected a trend in the exposure to fast-food outlets, such that neighbourhoods in the lowest income quartile had fewer fast-food outlets than higher-income neighbourhoods. These findings have similarities with studies conducted in the UK, but not in the USA. The results suggest there may be socio-economic factors other than income associated with food exposure in Europe.

  19. The premises is the premise: understanding off- and on-premises alcohol sales outlets to improve environmental alcohol prevention strategies.

    Science.gov (United States)

    Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie

    2011-06-01

    Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.

  20. A cross-sectional analysis of the relationship between tobacco and alcohol outlet density and neighbourhood deprivation.

    Science.gov (United States)

    Shortt, Niamh K; Tisch, Catherine; Pearce, Jamie; Mitchell, Richard; Richardson, Elizabeth A; Hill, Sarah; Collin, Jeff

    2015-10-05

    There is a strong socio-economic gradient in both tobacco-and alcohol-related harm. One possible factor contributing to this social gradient may be greater availability of tobacco and alcohol in more socially-deprived areas. A higher density of tobacco and alcohol outlets is not only likely to increase supply but also to raise awareness of tobacco/alcohol brands, create a competitive local market that reduces product costs, and influence local social norms relating to tobacco and alcohol consumption. This paper examines the association between the density of alcohol and tobacco outlets and neighbourhood-level income deprivation. Using a national tobacco retailer register and alcohol licensing data this paper calculates the density of alcohol and tobacco retail outlets per 10,000 population for small neighbourhoods across the whole of Scotland. Average outlet density was calculated for neighbourhoods grouped by their level of income deprivation. Associations between outlet density and deprivation were analysed using one way analysis of variance. There was a positive linear relationship between neighbourhood deprivation and outlets for both tobacco (p sales alcohol (p sales and on-sales alcohol outlets. The social gradient evident in alcohol and tobacco supply may be a contributing factor to the social gradient in alcohol- and tobacco-related disease. Policymakers should consider such gradients when creating tobacco and alcohol control policies. The potential contribution to public health, and health inequalities, of reducing the physical availability of both alcohol and tobacco products should be examined in developing broader supply-side interventions.

  1. Supermarket and fast-food outlet exposure in Copenhagen

    DEFF Research Database (Denmark)

    Svastisalee, Chalida Mae; Jensen, Helene Nordahl; Glumer, Charlotte

    2011-01-01

    and neighbourhood-level socio-economic indicators. Food business addresses were obtained from commercial and public business locators and geocoded using a geographic information system for all neighbourhoods in the city of Copenhagen (n 400). The regression of counts of fast-food outlets and supermarkets v...

  2. Gastrojejunostomy for gastric outlet obstruction in patients with ...

    African Journals Online (AJOL)

    Sixty patients were discharged from hospital having resumed normal eating. Their median survival after surgery was 9 months. Conclusion. Gastrojejunostomy offers worthwhile palliation and may prolong survival in a significant group of patients with irresectable gastric carcinoma and gastric outlet obstruction. South African ...

  3. Coupling of a discrete ordinate 3-D radiant heat transfer model with the PHOENICS fluid mechanics software; Couplage d`un modele radiatif tridimensionnel aux ordonnees discretes au logiciel de mecanique des fluides phoenics

    Energy Technology Data Exchange (ETDEWEB)

    Muller, J [IRSID, Institut de Recherches Siderurgie, 57 - Maizieres-les-Metz (France)

    1997-12-31

    Radiant heat transfer is the main solution retained in many iron and steel metallurgy installations (re-heating and annealing furnaces etc..). Today, it has become important to dispose of performing radiant heat transfer models in heat transfer and fluid mechanics simulation softwares, and well adapted to multidimensional industrial problems. This work presents the discrete ordinate radiant heat transfer model developed at the IRSID (the French institute of research in iron and steel metallurgy) and coupled with the PHOENICS heat transfer-fluid mechanics software. Three modeling approaches are presented concerning the radiative properties of gases (H{sub 2}O-CO{sub 2}). A ``weighted grey gases sum`` model gives satisfactory results for several 1-D validation cases. (J.S.) 20 refs.

  4. Coupling of a discrete ordinate 3-D radiant heat transfer model with the PHOENICS fluid mechanics software; Couplage d`un modele radiatif tridimensionnel aux ordonnees discretes au logiciel de mecanique des fluides phoenics

    Energy Technology Data Exchange (ETDEWEB)

    Muller, J. [IRSID, Institut de Recherches Siderurgie, 57 - Maizieres-les-Metz (France)

    1996-12-31

    Radiant heat transfer is the main solution retained in many iron and steel metallurgy installations (re-heating and annealing furnaces etc..). Today, it has become important to dispose of performing radiant heat transfer models in heat transfer and fluid mechanics simulation softwares, and well adapted to multidimensional industrial problems. This work presents the discrete ordinate radiant heat transfer model developed at the IRSID (the French institute of research in iron and steel metallurgy) and coupled with the PHOENICS heat transfer-fluid mechanics software. Three modeling approaches are presented concerning the radiative properties of gases (H{sub 2}O-CO{sub 2}). A ``weighted grey gases sum`` model gives satisfactory results for several 1-D validation cases. (J.S.) 20 refs.

  5. Shopper Loyalty to Whom? Chain Versus Outlet Loyalty in the Context of Store Acquisitions

    NARCIS (Netherlands)

    van Lin, Arjen; Gijsbrechts, E.

    2014-01-01

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  6. Shopper loyalty to whom? Chain versus outlet loyalty in the context of store acquisitions

    NARCIS (Netherlands)

    van Lin, A.I.J.G.; Gijsbrechts, E.

    When patronizing stores, consumers may exhibit loyalty not only to a retail chain but also to a specific outlet. This distinction is important in a dynamic retail environment: if a store changes ownership, chain loyalty makes customers inclined to seek out another outlet of the former chain, whereas

  7. Smart Control of Air Climatization System in Function on the Values of Mean Local Radiant Temperature

    Directory of Open Access Journals (Sweden)

    Giuseppe Cannistraro

    2015-08-01

    Full Text Available The hygrothermal comfort indoor conditions are defined as: those environmental conditions in which an individual exposed, expresses a state of satisfaction. These conditions cannot always be achieved anywhere in an optimal way and economically; in some cases they can be obtained only in work environments specific areas. This could be explained because of air conditioning systems designing is generally performed both on the basis of the fundamental parameters’ average values, such as temperature, velocity and relative humidity (Ta, va e φa and derived parameters such as operating temperature and mean radiant one (Top eTmr. However, in some specific cases - large open-spaces or in case of radiating surfaces - the descriptors defining indoor comfort conditions, based on average values, do not provide the optimum values required during the air conditioning systems design phase. This is largely due to the variability of real environmental parameters values compared to the average ones taken as input in the calculation. The results obtained in previous scientific papers on the thermal comfort have been the driving element of this work. It offers a simple, original and clever way of thinking about the new domotic systems for air conditioning, based on the “local mean radiant temperature.” This is a very important parameter when one wants to analyze comfort in environments characterized by the presence of radiating surfaces, as will be seen hereinafter. In order to take into account the effects of radiative exchanges in the open-space workplace, where any occupant may find themselves in different temperature and humidity conditions, this paper proposes an action on the domotic climate control, with ducts and vents air distribution placed in different zones. Comparisons were performed between the parameters values representing the punctual thermal comfort, with the Predicted Mean Vote PMV, in an environment marked by radiating surfaces (i

  8. Modeling of hydronic radiant cooling of a thermally homeostatic building using a parametric cooling tower

    International Nuclear Information System (INIS)

    Ma, Peizheng; Wang, Lin-Shu; Guo, Nianhua

    2014-01-01

    Highlights: • Investigated cooling of thermally homeostatic buildings in 7 U.S. cities by modeling. • Natural energy is harnessed by cooling tower to extract heat for building cooling. • Systematically studied possibility and conditions of using cooling tower in buildings. • Diurnal ambient temperature amplitude is taken into account in cooling tower cooling. • Homeostatic building cooling is possible in locations with large ambient T amplitude. - Abstract: A case is made that while it is important to mitigate dissipative losses associated with heat dissipation and mechanical/electrical resistance for engineering efficiency gain, the “architect” of energy efficiency is the conception of best heat extraction frameworks—which determine the realm of possible efficiency. This precept is applied to building energy efficiency here. Following a proposed process assumption-based design method, which was used for determining the required thermal qualities of building thermal autonomy, this paper continues this line of investigation and applies heat extraction approach investigating the extent of building partial homeostasis and the possibility of full homeostasis by using cooling tower in one summer in seven selected U.S. cities. Cooling tower heat extraction is applied parametrically to hydronically activated radiant-surfaces model-buildings. Instead of sizing equipment as a function of design peak hourly temperature as it is done in heat balance design-approach of selecting HVAC equipment, it is shown that the conditions of using cooling tower depend on both “design-peak” daily-mean temperature and the distribution of diurnal range in hourly temperature (i.e., diurnal temperature amplitude). Our study indicates that homeostatic building with natural cooling (by cooling tower alone) is possible only in locations of special meso-scale climatic condition such as Sacramento, CA. In other locations the use of cooling tower alone can only achieve homeostasis

  9. 40 CFR 63.3555 - How do I determine the outlet THC emissions and add-on control device emission destruction or...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...

  10. Local concentration of fast-food outlets is associated with poor nutrition and obesity.

    Science.gov (United States)

    Kruger, Daniel J; Greenberg, Emily; Murphy, Jillian B; DiFazio, Lindsay A; Youra, Kathryn R

    2014-01-01

    We investigated the relationship of the local availability of fast-food restaurant locations with diet and obesity. We geocoded addresses of survey respondents and fast-food restaurant locations to assess the association between the local concentration of fast-food outlets, BMI, and fruit and vegetable consumption. The survey was conducted in Genesee County, Michigan. There were 1345 individuals included in this analysis, and the response rate was 25%. The Speak to Your Health! Community Survey included fruit and vegetable consumption items from the Behavioral Risk Factor Surveillance System, height, weight, and demographics. We used ArcGIS to map fast-food outlets and survey respondents. Stepwise linear regressions identified unique predictors of body mass index (BMI) and fruit and vegetable consumption. Survey respondents had 8 ± 7 fast-food outlets within 2 miles of their home. Individuals living in close proximity to fast-food restaurants had higher BMIs t(1342) = 3.21, p food availability, which may constrain the success of nutrition promotion efforts. Efforts to decrease the local availability of unhealthy foods as well as programs to help consumers identify strategies for obtaining healthy meals at fast-food outlets may improve health outcomes.

  11. Climate Model Evaluation using New Datasets from the Clouds and the Earth's Radiant Energy System (CERES)

    Science.gov (United States)

    Loeb, Norman G.; Wielicki, Bruce A.; Doelling, David R.

    2008-01-01

    There are some in the science community who believe that the response of the climate system to anthropogenic radiative forcing is unpredictable and we should therefore call off the quest . The key limitation in climate predictability is associated with cloud feedback. Narrowing the uncertainty in cloud feedback (and therefore climate sensitivity) requires optimal use of the best available observations to evaluate and improve climate model processes and constrain climate model simulations over longer time scales. The Clouds and the Earth s Radiant Energy System (CERES) is a satellite-based program that provides global cloud, aerosol and radiative flux observations for improving our understanding of cloud-aerosol-radiation feedbacks in the Earth s climate system. CERES is the successor to the Earth Radiation Budget Experiment (ERBE), which has widely been used to evaluate climate models both at short time scales (e.g., process studies) and at decadal time scales. A CERES instrument flew on the TRMM satellite and captured the dramatic 1998 El Nino, and four other CERES instruments are currently flying aboard the Terra and Aqua platforms. Plans are underway to fly the remaining copy of CERES on the upcoming NPP spacecraft (mid-2010 launch date). Every aspect of CERES represents a significant improvement over ERBE. While both CERES and ERBE measure broadband radiation, CERES calibration is a factor of 2 better than ERBE. In order to improve the characterization of clouds and aerosols within a CERES footprint, we use coincident higher-resolution imager observations (VIRS, MODIS or VIIRS) to provide a consistent cloud-aerosol-radiation dataset at climate accuracy. Improved radiative fluxes are obtained by using new CERES-derived Angular Distribution Models (ADMs) for converting measured radiances to fluxes. CERES radiative fluxes are a factor of 2 more accurate than ERBE overall, but the improvement by cloud type and at high latitudes can be as high as a factor of 5

  12. Simulation of water flows in multiple columns with small outlets

    International Nuclear Information System (INIS)

    Suh, Yong Kweon; Li, Zi Lu; Jeong, Jong Hyun; Lee, Jun Hee

    2006-01-01

    High-pressure die casting such as thixocasting and rheocasting is an effective process in the manufacturing automotive parts. Following the recent trend in the automotive manufacturing technologies, the product design subject to the die casting becomes more and more complex. Simultaneously the injection speed is also designed to be very high to establish a short cycle-time. Thus, the requirement of the die design becomes more demanding than ever before. In some cases the product's shape can have multiple slender manifolds. In such cases, design of the inlet and outlet parts of the die is very important in the whole manufacturing process. The main issues required for the qualified products are to attain gentle and uniform flow of the molten liquid within the passages of the die. To satisfy such issues, the inlet cylinder ('bed cylinder' in this paper) must be as large as possible and simultaneously the outlet opening at the end of each passage must be as small as possible. However these in turn obviously bring additional manufacturing costs caused by re-melting of the bed cylinder and increased power due to the small outlet-openings. The purpose of this paper is to develop effective simulation methods of calculation for fluid flows in multiple columns, which mimic the actual complex design, and to get some useful information which can give some contributions to the die-casting industry. We have used a commercial code CFX in the numerical simulation. The primary parameter involved is the size of the bed cylinder. We will show how the very small opening of the outlet can be treated with the aid of the porous model provided in the code. To check the validity of the numerical results we have also conducted a simple experiment by using water

  13. Communicating Ebola through social media and electronic news media outlets: A cross-sectional study.

    Science.gov (United States)

    Househ, Mowafa

    2016-09-01

    Social media and electronic news media activity are an important source of information for the general public. Yet, there is a dearth of research exploring the use of Twitter and electronic news outlets during significant worldly events such as the recent Ebola Virus scare. The purpose of this article is to investigate the use of Twitter and electronic news media outlets in communicating Ebola Virus information. A cross-sectional survey of Twitter data and Google News Trend data from 30 September till 29 October, 2014 was conducted. Between 30 September and 29 October, there were approximately 26 million tweets (25,925,152) that contained the word Ebola. The highest number of correlated activity for Twitter and electronic news outlets occurred on 16 October 2014. Other important peaks in Twitter data occurred on 1 October, 6 October, 8 October, and 12 October, 2014. The main influencers of the Twitter feeds were news media outlets. The study reveals a relationship between electronic news media publishing and Twitter activity around significant events such as Ebola. Healthcare organizations should take advantage of the relationship between electronic news media and trending events on social media sites such as Twitter and should work on developing social media campaigns in co-operation with leading electronic news media outlets (e.g. CNN, Yahoo, Reuters) that can have an influence on social media activity. © The Author(s) 2015.

  14. “Clavicular duplication causing thoracic outlet obstruction”: Unique ...

    African Journals Online (AJOL)

    A 22‑year‑old female student reported with features of neurogenic thoracic outlet syndrome mainly involving C8‑T1 components of the brachial plexus, seemingly originating from involvement in costo‑clavicular space. Radiograph of the shoulder revealed clavicular duplication. Neuro‑physiological studies corroborated the ...

  15. Bacteriological Analysis and Hygine Level of Food Outlets within Rufus Giwa Polytechnic, Owo, Ondo State, Nigeria.

    OpenAIRE

    Ibrahim TA; Akenroye OM; Osabiya OJ

    2013-01-01

    The bacteriological quality of three major food outlets in Rufus Giwa Polytechnic, Owo, was assessed using standard bacteriological methods. Swabs of hands of food vendors, table and plates in these outlets were assessed for total bacterial count, total coliform count and total E. coli count. A total of 789 bacterial colonies were isolated from hands of food handlers, tables and plates used for eating in the outlets. Eleven genera of bacteria were isolated and identified, they were; klebsiell...

  16. Change in alcohol outlet density and alcohol-related harm to population health (CHALICE

    Directory of Open Access Journals (Sweden)

    Fone David

    2012-06-01

    Full Text Available Abstract Background Excess alcohol consumption has serious adverse effects on health and violence-related harm. In the UK around 37% of men and 29% of women drink to excess and 20% and 13% report binge drinking. The potential impact on population health from a reduction in consumption is considerable. One proposed method to reduce consumption is to reduce availability through controls on alcohol outlet density. In this study we investigate the impact of a change in the density of alcohol outlets on alcohol consumption and alcohol-related harms to health in the community. Methods/Design A natural experiment of the effect of change in outlet density between 2005–09, in Wales, UK; population 2.4 million aged 16 years and over. Data on outlets are held by the 22 local authorities in Wales under The Licensing Act 2003. The study outcomes are change in (1 alcohol consumption using data from annual Welsh Health Surveys, (2 alcohol-related hospital admissions using the Patient Episode Database for Wales, (3 Accident & Emergency department attendances between midnight–6am, and (4 alcohol-related violent crime against the person, using Police data. The data will be anonymously record-linked within the Secure Anonymised Information Linkage Databank at individual and 2001 Census Lower Super Output Area levels. New methods of network analysis will be used to estimate outlet density. Longitudinal statistical analysis will use (1 multilevel ordinal models of consumption and logistic models of admissions and Accident & Emergency attendance as a function of change in individual outlet exposure, adjusting for confounding variables, and (2 spatial models of the change in counts/rates of each outcome measure and outlet density. We will assess the impact on health inequalities and will correct for population migration. Discussion This inter-disciplinary study requires expertise in epidemiology and public health, health informatics, medical statistics

  17. Heat transfer from the evaporator outlet to the charge of thermostatic expansion valves

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    outlet with a special mounting strap. The heat transfer is quite complex because it takes place both directly through the contact points between bulb and pipe and indirectly through the mounting strap The TXV has to react to temperature changes at the evaporator outlet. Therefore, the dynamic behavior...... of the valve (and thereby the whole refrigeration system) depends greatly on the heat transfer between the evaporator outlet tube and the charge in the bulb. In this paper a model for the overall heat transfer between the pipe and the charge is presented. Geometrical data and material properties have been kept...... been found to predict the time constant for the temperature development in the bulb within 1-10 %. Furthermore it has been found that app. 20% of the heat transfer takes place trough the mounting strap....

  18. Malignant gastric outlet obstruction managed by endoscopic stenting: a prospective single-centre study

    DEFF Research Database (Denmark)

    Havemann, Maria Cecilie; Adamsen, Sven; Wøjdemann, Morten

    2008-01-01

    -to-treat principle. All patients were offered endoscopic stenting. Oral intake before and after stenting was assessed using the gastric outlet obstruction score system (GOOSS). Various lengths of duodenal Hanaro(R) self-expanding nitinol stents were delivered through a therapeutic endoscope. Outcome criteria were......Objective. Endoscopic stenting for malignant gastric outlet obstruction was chosen as the primary strategy by which to palliate this complication, which is dominated by weight loss and anorexia. Advanced upper gastrointestinal tract cancers present late and life expectancy is limited. Only smaller...... multicentre studies point to endoscopic stenting as superior to surgery in terms of clinical outcome and cost. Material and methods. Forty-five consecutive patients with gastric outlet obstruction as a result of advanced upper GI-tract malignancy were enrolled in accordance with the intention...

  19. Surf zone entrainment, along-shore transport, and human health implications of pollution from tidal outlets

    Science.gov (United States)

    Grant, S. B.; Kim, J. H.; Jones, B. H.; Jenkins, S. A.; Wasyl, J.; Cudaback, C.

    2005-10-01

    Field experiments and modeling studies were carried out to characterize the surf zone entrainment and along-shore transport of pollution from two tidal outlets that drain into Huntington Beach and Newport Beach, popular public beaches in southern California. The surf zone entrainment and near-shore transport of pollutants from these tidal outlets appears to be controlled by prevailing wave conditions and coastal currents, and fine-scale features of the flow field around the outlets. An analysis of data from dye experiments and fecal indicator bacteria monitoring studies reveals that the along-shore flux of surf zone water is at least 50 to 300 times larger than the cross-shore flux of surf zone water. As a result, pollutants entrained in the surf zone hug the shore, where they travel significant distances parallel to the beach before diluting to extinction. Under the assumption that all surf zone pollution at Huntington Beach originates from two tidal outlets, the Santa Ana River and Talbert Marsh outlets, models of mass and momentum transport in the surf zone approximately capture the observed tidal phasing and magnitude of certain fecal indicator bacteria groups (total coliform) but not others (Escherichia coli and enterococci), implying the existence of multiple sources of, and/or multiple transport pathways for, fecal pollution at this site. The intersection of human recreation and near-shore pollution pathways implies that, from a human health perspective, special care should be taken to reduce the discharge of harmful pollutants from land-side sources of surface water runoff, such as tidal outlets and storm drains.

  20. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review.

    Science.gov (United States)

    Lamb, Karen E; Thornton, Lukar E; Cerin, Ester; Ball, Kylie

    2015-01-01

    Inequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses. Searches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status. Fifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer). To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation. With advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  1. Statistical Approaches Used to Assess the Equity of Access to Food Outlets: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Karen E. Lamb

    2015-07-01

    Full Text Available BackgroundInequalities in eating behaviours are often linked to the types of food retailers accessible in neighbourhood environments. Numerous studies have aimed to identify if access to healthy and unhealthy food retailers is socioeconomically patterned across neighbourhoods, and thus a potential risk factor for dietary inequalities. Existing reviews have examined differences between methodologies, particularly focussing on neighbourhood and food outlet access measure definitions. However, no review has informatively discussed the suitability of the statistical methodologies employed; a key issue determining the validity of study findings. Our aim was to examine the suitability of statistical approaches adopted in these analyses.MethodsSearches were conducted for articles published from 2000-2014. Eligible studies included objective measures of the neighbourhood food environment and neighbourhood-level socio-economic status, with a statistical analysis of the association between food outlet access and socio-economic status.ResultsFifty-four papers were included. Outlet accessibility was typically defined as the distance to the nearest outlet from the neighbourhood centroid, or as the number of food outlets within a neighbourhood (or buffer. To assess if these measures were linked to neighbourhood disadvantage, common statistical methods included ANOVA, correlation, and Poisson or negative binomial regression. Although all studies involved spatial data, few considered spatial analysis techniques or spatial autocorrelation.ConclusionsWith advances in GIS software, sophisticated measures of neighbourhood outlet accessibility can be considered. However, approaches to statistical analysis often appear less sophisticated. Care should be taken to consider assumptions underlying the analysis and the possibility of spatially correlated residuals which could affect the results.

  2. Three dimensional modelling and numerical analysis of super-radiant harmonic emission in FEL (optical klystron)

    International Nuclear Information System (INIS)

    Gover, A.; Friedman, A.; Luccio, A.

    1986-09-01

    A full 3-D Analysis of super-radiant (bunched electron) free electron harmonic radiation is presented. A generalized form of the FEL pendulum equation was derived and numerically solved. Both spectral and phasor formulation were developed to treat the radiation in the time domain. In space the radiation field is expanded in terms of either a set of free space discrete modes or plane waves. The numerical solutions reveal some new distinctly 3-D effects to which we provide a physical explanation. 12 refs., 9 figs., 5 tabs

  3. Experimental research on the indoor temperature and humidity fields in radiant ceiling air-conditioning system under natural ventilation

    Science.gov (United States)

    Huang, Tao; Xiang, Yutong; Wang, Yonghong

    2017-05-01

    In this paper, the indoor temperature and humidity fields of the air in a metal ceiling radiant panel air conditioning system with fresh air under natural ventilation were researched. The temperature and humidity distributions at different height and different position were compared. Through the computation analysis of partial pressure of water vapor, the self-recovery characteristics of humidity after the natural ventilation was discussed.

  4. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    OpenAIRE

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate...

  5. Local food environments are associated with girls' energy, sugar-sweetened beverage and snack-food intakes.

    Science.gov (United States)

    Deierlein, Andrea L; Galvez, Maida P; Yen, Irene H; Pinney, Susan M; Biro, Frank M; Kushi, Lawrence H; Teitelbaum, Susan; Wolff, Mary S

    2014-10-01

    To describe availability and frequency of use of local snack-food outlets and determine whether reported use of these outlets was associated with dietary intakes. Data were cross-sectional. Availability and frequency of use of three types of local snack-food outlets were reported. Daily dietary intakes were based on the average of up to four 24 h dietary recalls. Multivariable linear regression models estimated average daily intakes of energy, sugar-sweetened beverages (SSB) and snack foods/sweets associated with use of outlets. Multi-site, observational cohort study in the USA, 2004-2006. Girls aged 6-8 years (n 1010). Weekly frequency of use of local snack-food outlets increased with number of available types of outlets. Girls with access to only one type of outlet reported consuming food/beverage items less frequently than girls with access to two or three types of outlets (P snack foods/sweets intakes increased with greater use of outlets. Girls who reported using outlets>1 to 3 times/week consumed 0·27 (95 % CI 0·13, 0·40) servings of SSB more daily than girls who reported no use. Girls who reported using outlets>3 times/week consumed 449·61 (95 % CI 134·93, 764·29) kJ, 0·43 (95 % CI 0·29, 0·58) servings of SSB and 0·38 (95 % CI 0·12, 0·65) servings of snack foods/sweets more daily than those who reported no use. Girls' frequency of use of local snack-food outlets increases with the number of available types of outlets and is associated with greater daily intakes of energy and servings of SSB and snack foods/sweets.

  6. CFD Analysis on a Core Outlet Flow through the Fuel Alignment Plant of SMART

    International Nuclear Information System (INIS)

    Kim, Y. I.; Bae, Y. M.; Kim, K. K.

    2014-01-01

    CFD (Computational Fluid Dynamics) simulations were performed to confirm the core flow distribution for SMART, which acquired standard design approval in 2012. In this paper, CFD simulation is also used to calculate the pressure distribution of a core outlet, a Fuel Alignment Plate (FAP), for SMART. In SMART, the fluid discharged from the Steam Generator comes into a Flow Mixing Header Assembly (FMHA), and is rearranged and split into a very fine size. The FMHA is greatly important for enhancing the flow distribution of a downcomer during a normal operation, transient, and even accidents. Then, the fluid discharged from the FMHA flows into the core upstream through flow skirt holes. The Low Core Support Plate (LCSP) reallocates the flow introducing into the inlet core from the core upstream. The deviation of flow distribution becomes smaller or almost disappears by LCSP holes having relatively large loss coefficient compared to the downstream flow deviation. In an open core, the flow deviation at the core inlet region is diminished by cross flow as it goes upward. Near the core outlet, the flow distribution can be distorted by the influence of a Fuel Alignment Plate (FAP) installed above the fuels. In this paper, the effect of the core outlet flow structure such as the FAP holes of SMART is investigated. Before the calculation, the influences of mesh size and turbulence models are inspected. CFD simulations were performed to investigate the effect of FAP flow holes on the core outlet flow of SMART. As a preliminary study, the dependency of the mesh size and turbulence models was tested; a fine grid was applied, the effect of which is negligible, and the core outlet flow is not sensitive to the turbulence models. In brief, the flow resistance of FAP is less than 15% of that of the fuel assemblies. The flow resistance deviation between two flow path patterns is less than 1% of that of active core. Even two flow path patterns located at the downstream location of the

  7. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.; Breward, C. J. W.; Howell, P. D.; Oliver, J. M.

    2012-01-01

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown

  8. [Thermal energy utilization analysis and energy conservation measures of fluidized bed dryer].

    Science.gov (United States)

    Xing, Liming; Zhao, Zhengsheng

    2012-07-01

    To propose measures for enhancing thermal energy utilization by analyzing drying process and operation principle of fluidized bed dryers,in order to guide optimization and upgrade of fluidized bed drying equipment. Through a systematic analysis on drying process and operation principle of fluidized beds,the energy conservation law was adopted to calculate thermal energy of dryers. The thermal energy of fluidized bed dryers is mainly used to make up for thermal consumption of water evaporation (Qw), hot air from outlet equipment (Qe), thermal consumption for heating and drying wet materials (Qm) and heat dissipation to surroundings through hot air pipelines and cyclone separators. Effective measures and major approaches to enhance thermal energy utilization of fluidized bed dryers were to reduce exhaust gas out by the loss of heat Qe, recycle dryer export air quantity of heat, preserve heat for dry towers, hot air pipes and cyclone separators, dehumidify clean air in inlets and reasonably control drying time and air temperature. Such technical parameters such air supply rate, air inlet temperature and humidity, material temperature and outlet temperature and humidity are set and controlled to effectively save energy during the drying process and reduce the production cost.

  9. Full Scale Measurements and CFD Investigations of a Wall Radiant Cooling System Based on Plastic Capillary Tubes in Thin Concrete Walls

    DEFF Research Database (Denmark)

    Mikeska, Tomás; Fan, Jianhua; Svendsen, Svend

    2017-01-01

    Densely occupied spaces such as classrooms can very often have problems with overheating. It can be difficult to cool such spaces by means of a ventilation system without creating draughts and causing discomfort for occupants. The use of a wall radiant cooling system is a suitable option for spaces...

  10. Ignition of Cellulosic Paper at Low Radiant Fluxes

    Science.gov (United States)

    White, K. Alan

    1996-01-01

    The ignition of cellulosic paper by low level thermal radiation is investigated. Past work on radiative ignition of paper is briefly reviewed. No experimental study has been reported for radiative ignition of paper at irradiances below 10 Watts/sq.cm. An experimental study of radiative ignition of paper at these low irradiances is reported. Experimental parameters investigated and discussed include radiant power levels incident on the sample, the method of applying the radiation (focussed vs. diffuse Gaussian source), the presence and relative position of a separate pilot ignition source, and the effects of natural convection (buoyancy) on the ignition process in a normal gravity environment. It is observed that the incident radiative flux (in W/sq.cm) has the greatest influence on ignition time. For a given flux level, a focussed Gaussian source is found to be advantageous to a more diffuse, lower amplitude, thermal source. The precise positioning of a pilot igniter relative to gravity and to the fuel sample affects the ignition process, but the precise effects are not fully understood. Ignition was more readily achieved and sustained with a horizontal fuel sample, indicating the buoyancy plays a role in the ignition process of cellulosic paper. Smoldering combustion of doped paper samples was briefly investigated, and results are discussed.

  11. Fruit and Vegetable Intake in Adolescents: Association with Socioeconomic Status and Exposure to Supermarkets and Fast Food Outlets

    Directory of Open Access Journals (Sweden)

    Chalida M. Svastisalee

    2012-01-01

    Full Text Available Background. We investigated differences in family social class associations between food outlet exposure and fruit and vegetable intake. Methods. We supplemented data from the 2006 Health Behavior in School Aged Children Study (n=6,096 with geocoded food outlet information surrounding schools (n=80. We used multilevel logistic regression to examine associations between infrequent fruit and vegetable intake and supermarket and fast food outlet concentration, stratified by family social class. Results. Boys and older children were most likely to eat fruit and vegetables infrequently. High fast food outlet exposure was marginally significant for low fruit intake in low social class children only. Children from middle and low social class backgrounds attending schools with combined high fast food outlet/low supermarket exposure were most likely to report infrequent fruit intake (ORlow=1.60; CI:  1.02–2.45; ORmid=1.40; CI:  1.03–190. Children from low social class backgrounds were also likely to report infrequent vegetable intake, given low supermarket and high fast food outlet exposure (OR=1.79; CI:  0.99–3.21. Conclusion. Our findings suggest social class modifies the relationship between intake and food outlet concentration. School interventions improving fruit and vegetable intake should consider neighborhood surroundings, targetting older children from low social class backgrounds.

  12. The impact of the tobacco retail outlet environment on adult cessation and differences by neighborhood poverty.

    Science.gov (United States)

    Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Pearson, Jennifer L; Xiao, Haijun; Vallone, Donna; Kirchner, Thomas R

    2015-01-01

    This study examined the impact of tobacco retail outlets on cessation outcomes over time among non-treatment-seeking smokers and assessed differences by neighborhood poverty and individual factors. Observational longitudinal cohort study using geospatial data. We used generalized estimating equations to examine cessation outcomes in relation to the proximity and density of tobacco retail outlets near the home. Eight large Designated Media Areas across the United States. A total of 2377 baseline smokers followed over three waves from 2008 to 2010. Outlet addresses were identified through North American Industry Classification System codes and proximity and density measures were constructed for each participant at each wave. Outcomes included past 30-day abstinence and pro-cessation attitudes. Smokers in high poverty census tracts living between 500 m and 1.9 km from an outlet were over two times more likely to be abstinent than those living fewer than 500 m from an outlet (P < 0.05). Density within 500 m of home was associated with reduced abstinence [odds ratio (OR) = 0.94; confidence interval (CI) = 0.90, 0.98) and lower pro-cessation attitudes (Coeff = -0.07, CI = -0.10, -0.03) only in high poverty areas. In low poverty areas, density within 500 m was associated with greater pro-cessation attitudes (OR = 0.06; CI = 0.01, 0.12). Gender, education and heaviness of smoking did not moderate the impact of outlet proximity and density on cessation outcomes. In the United States, density of tobacco outlets within 500 m of the home residence appears to be negatively associated with smoking abstinence and pro-cessation attitudes only in poor areas. © 2014 Society for the Study of Addiction.

  13. EXERGY AND CARBON CREDITS FOR SERIES CONNECTED N PHOTOVOLTAIC THERMAL - COMPOUND PARABOLIC CONCENTRATOR (PVT-CPC) COLLECTOR: AT CONSTANT OUTLET TEMPERATURE

    OpenAIRE

    Rohit Tripathi 1,*, G. N. Tiwari 2

    2017-01-01

    In the present study, overall energy and exergy performance of partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) (25% covered by glass to glass PV module) collector connected in series have been carried out at constant outlet temperature mode. Further, comparison in performance for partially covered N photovoltaic thermal - compound parabolic concentrators (PVT-CPC) [case (i)] and N compound parabolic concentrators (CPC) collector [case (ii)] connected in s...

  14. Disseny de calefacció amb terra radiant d'una casa a l'horta de Lleida mitjançant energia geotèrmica

    OpenAIRE

    Fillat Sobrino, Jordi

    2008-01-01

    S'ha realitzat el disseny de calefacció d'una vivenda mitjançant energia geotèrmica de baixa temperatura, amb un bescanviador vertical de 80 m de profunditat. El sistema de calefacció és de terra radiant en forma d'espiral.

  15. Perceived air quality, thermal comfort, and SBS symptoms at low air temperature and increased radiant temperature

    DEFF Research Database (Denmark)

    Toftum, Jørn; Reimann, Gregers Peter; Foldbjerg, P.

    2002-01-01

    source present at the low temperature. To maintain overall thermal neutrality, the low air temperature was partly compensated for by individually controlled radiant heating, and partly by allowing subjects to modify clothing insulation. A reduction of the air temperature from 23 deg.C to 18 deg.......C suggested an improvement of the perceived air quality, while no systematic effect on symptom intensity was observed. The overall indoor environment was evaluated equally acceptable at both temperatures due to local thermal discomfort at the low air temperature....

  16. Benefits and limitations of animal models in partial bladder outlet obstruction for translational research.

    Science.gov (United States)

    Kitta, Takeya; Kanno, Yukiko; Chiba, Hiroki; Higuchi, Madoka; Ouchi, Mifuka; Togo, Mio; Moriya, Kimihiko; Shinohara, Nobuo

    2018-01-01

    The functions of the lower urinary tract have been investigated for more than a century. Lower urinary tract symptoms, such as incomplete bladder emptying, weak urine stream, daytime urinary frequency, urgency, urge incontinence and nocturia after partial bladder outlet obstruction, is a frequent cause of benign prostatic hyperplasia in aging men. However, the pathophysiological mechanisms have not been fully elucidated. The use of animal models is absolutely imperative for understanding the pathophysiological processes involved in bladder dysfunction. Surgical induction has been used to study lower urinary tract functions of numerous animal species, such as pig, dog, rabbit, guinea pig, rat and mouse, of both sexes. Several morphological and functional modifications under partial bladder outlet obstruction have not only been observed in the bladder, but also in the central nervous system. Understanding the changes of the lower urinary tract functions induced by partial bladder outlet obstruction would also contribute to appropriate drug development for treating these pathophysiological conditions. In the present review, we discuss techniques for creating partial bladder outlet obstruction, the characteristics of several species, as well as issues of each model, and their translational value. © 2017 The Japanese Urological Association.

  17. A hydrologic regression sediment-yield model for two ungaged watershed outlet stations in Africa

    International Nuclear Information System (INIS)

    Moussa, O.M.; Smith, S.E.; Shrestha, R.L.

    1991-01-01

    A hydrologic regression sediment-yield model was established to determine the relationship between water discharge and suspended sediment discharge at the Blue Nile and the Atbara River outlet stations during the flood season. The model consisted of two main submodels: (1) a suspended sediment discharge model, which was used to determine suspended sediment discharge for each basin outlet; and (2) a sediment rating model, which related water discharge and suspended sediment discharge for each outlet station. Due to the absence of suspended sediment concentration measurements at or near the outlet stations, a minimum norm solution, which is based on the minimization of the unknowns rather than the residuals, was used to determine the suspended sediment discharges at the stations. In addition, the sediment rating submodel was regressed by using an observation equations procedure. Verification analyses on the model were carried out and the mean percentage errors were found to be +12.59 and -12.39, respectively, for the Blue Nile and Atbara. The hydrologic regression model was found to be most sensitive to the relative weight matrix, moderately sensitive to the mean water discharge ratio, and slightly sensitive to the concentration variation along the River Nile's course

  18. Epidemiology and pathogenesis of thoracic outlet syndrome

    Directory of Open Access Journals (Sweden)

    Wojcik Gustaw

    2015-03-01

    Full Text Available The superior thoracic aperture is a place particularly vulnerable to the occurrence of tissue conflict and the development of a number of neurovascular changes carrying a risk of upper limb dysfunction. The triggering factor in this case is the pressure on the nerve vascular elements brought about by too large muscles of the chest and neck, clavicle fracture and dislocation of the upper ribs, anomalies in the form of ribs, in the neck, or by apex of the lung tumors. Each anatomical anomaly may be a cause of a number of lesions and lead to the development of the disease. Due to the nature of the oppressed structures, there are two basic groups: neurogenic and vascular. The most common variant giving clinical symptoms is neurogenic thoracic outlet syndrome. In this, the compression ratio, the brachial plexus, and for this reason, the vascular surface of the upper limb dysfunction is often overlooked. However, the vascular variant, and especially arterial sub-variant, is very dangerous because it can give complications even in the form of aneurysms, and even upper limb ischemia. The aim of the study is to present the most common changes in the thoracic outlet causing functional disorders of the upper limb.

  19. Operation of heat pumps for smart grid integrated buildings with thermal energy storage

    NARCIS (Netherlands)

    Finck, C.J.; Li, R.; Zeiler, W.

    2017-01-01

    A small scale office building consisting of radiant heating, a heat pump, and a water thermal energy storage tank is implemented in an optimal control framework. The optimal control aims to minimize operational electricity costs of the heat pump based on real-time power spot market prices. Optimal

  20. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    International Nuclear Information System (INIS)

    Camarda, C.J.; Basiulis, A.

    1983-08-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors

  1. DOE Zero Energy Ready Home Case Study: Amaris Homes, Afton Model

    Energy Technology Data Exchange (ETDEWEB)

    Pacific Northwest National Laboratory

    2017-09-01

    Amaris Homes built this 3,734-ft2 home in Afton, Minnesota, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A high-efficiency gas boiler provides hot water for the zoned radiant floor system as well as for faucets and showers. A high-efficiency heat pump provides zoned cooling.

  2. Operativ behandling af thoracic outlet syndrome

    DEFF Research Database (Denmark)

    Birkeland, Peter; Stiasny, Jerzy

    2012-01-01

    of the brachial plexus. At surgery, we found and severed a fibrous band that compressed the inferior trunk. Postoperatively, the pain subsided and fine hand movements improved. One patient had no cervical rib, however, in the two other cases we found rudimentary cervical ribs. Magnetic resonance imaging......We present three cases with longstanding true neurogenic thoracic outlet syndrome. All patients had aching pain in the shoulder, arm and ulnar border of the hand. On examination, we found atrophy of the hand muscles. Electromyography revealed signs of compromised function of the inferior trunk...

  3. PPOOLEX experiments with a modified blowdown pipe outlet

    International Nuclear Information System (INIS)

    Laine, J.; Puustinen, M.; Raesaenen, A.

    2009-08-01

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  4. PPOOLEX experiments with a modified blowdown pipe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Laine, J.; Puustinen, M.; Raesaenen, A. (Lappeenranta Univ. of Technology, Nuclear Safety Research Unit (Finland))

    2009-08-15

    This report summarizes the results of the experiments with a modified blowdown pipe outlet carried out with the PPOOLEX test facility designed and constructed at Lappeenranta University of Technology. Steam was blown into the dry well compartment and from there through a vertical DN200 blowdown pipe to the condensation pool. Four reference experiments with a straight pipe and ten with the Forsmark type collar were carried out. The main purpose of the experiment series was to study the effect of a blowdown pipe outlet collar design on loads caused by chugging phenomena (rapid condensation) while steam is discharged into the condensation pool. The PPOOLEX test facility is a closed stainless steel vessel divided into two compartments, dry well and wet well. During the experiments the initial temperature level of the condensation pool water was either 20-25 or 50-55 deg. C. The steam flow rate varied from 400 to 1200 g/s and the temperature of incoming steam from 142 to 185 deg. C. In the experiments with 20-25 deg. C pool water, even 10 times higher pressure pulses were measured inside the blowdown pipe in the case of the straight pipe than with the collar. In this respect, the collar design worked as planned and removed the high pressure spikes from the blowdown pipe. Meanwhile, there seemed to be no suppressing effect on the loads due to the collar in the pool side in this temperature range. Registered loads in the pool were approximately in the same range (or even a little higher) with the collar as with the straight pipe. In the experiments with 50-55 deg. C pool water no high pressure pulses were measured inside the blowdown pipe either with the straight pipe or with the collar. In this case, more of the suppressing effect is probably due to the warmer pool water than due to the modified pipe outlet. It has been observed already in the earlier experiments with a straight pipe in the POOLEX and PPOOLEX facilities that warm pool water has a diminishing effect on

  5. Access to food retail outlets in County Durham, UK: a pragmatic cross-sectional study.

    Science.gov (United States)

    Mills, Susanna; Wright, Tim

    2015-02-26

    Strong links exist between deprivation, obesity, and dietary quality. Increasing interest has focussed on the concept of access to food and so-called food deserts, defined by a policy working group of the UK Low Income Project Team in 1995 as "areas of relative exclusion where people experience physical and economic barriers to accessing healthy food". We aimed to establish the accessibility of food retail outlets in County Durham, a county in north-east England, UK, considering physical access, affordability, and food range and quality. In a pragmatic cross-sectional study in County Durham, we used information from town surveys and food business databases to locate and identify food retail outlets. The prevalence of deprivation, obesity, retail outlets, takeaway outlets, and ratio of retail to takeaway outlets was mapped, to establish local food access, and any associations with deprivation and obesity. The times taken to travel from residences to supermarkets using private car and public transport were also measured. 400 members of the community participated in eight focus groups and commissioned on-street surveys. Focus group transcripts were reviewed alongside the on-street survey responses to identify key issues. Most residents shopped at least weekly for food (n=368, 92%), used a supermarket for their main food shop (372, 93%), travelled for up to 15 min (340, 85%), and used a car for transport (188, 47%). Many survey respondents indicated high levels of satisfaction with food retail outlets (average rating 8·7 out of 10 for agreement with the statement "Overall I am satisfied with the shop where I do my main food shopping"), although financial constraints and transport inconvenience were identified as barriers. Difficulties with food shopping were more widely described in focus groups, and many individuals felt that local shopping provision had declined, with an emergent excess of takeaway outlets. Food retail access was reduced for the disabled, full

  6. A description of interventions promoting healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England: a systematic mapping and evidence synthesis

    OpenAIRE

    Hillier-Brown, Frances C.; Summerbell, Carolyn D.; Moore, Helen J.; Wrieden, Wendy L.; Adams, Jean; Abraham, Charles; Adamson, Ashley; Ara?jo-Soares, Vera; White, Martin; Lake, Amelia A.

    2017-01-01

    $\\textbf{Background:}$ Ready-to-eat meals (to eat in, to take away or to be delivered) sold by food outlets are often more energy dense and nutrient poor compared with meals prepared at home, making them a reasonable target for public health intervention. The aim of the research presented in this paper was to systematically identify and describe interventions to promote healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England. $\\...

  7. Simulation of a proposed emergency outlet from Devils Lake, North Dakota

    Science.gov (United States)

    Vecchia, Aldo V.

    2002-01-01

    From 1993 to 2001, Devils Lake rose more than 25 feet, flooding farmland, roads, and structures around the lake and causing more than $400 million in damages in the Devils Lake Basin. In July 2001, the level of Devils Lake was at 1,448.0 feet above sea level1, which was the highest lake level in more than 160 years. The lake could continue to rise to several feet above its natural spill elevation to the Sheyenne River (1,459 feet above sea level) in future years, causing extensive additional flooding in the basin and, in the event of an uncontrolled natural spill, downstream in the Red River of the North Basin as well. The outlet simulation model described in this report was developed to determine the potential effects of various outlet alternatives on the future lake levels and water quality of Devils Lake.Lake levels of Devils Lake are controlled largely by precipitation on the lake surface, evaporation from the lake surface, and surface inflow. For this study, a monthly water-balance model was developed to compute the change in total volume of Devils Lake, and a regression model was used to estimate monthly water-balance data on the basis of limited recorded data. Estimated coefficients for the regression model indicated fitted precipitation on the lake surface was greater than measured precipitation in most months, fitted evaporation from the lake surface was less than estimated evaporation in most months, and ungaged inflow was about 2 percent of gaged inflow in most months. Dissolved sulfate was considered to be the key water-quality constituent for evaluating the effects of a proposed outlet on downstream water quality. Because large differences in sulfate concentrations existed among the various bays of Devils Lake, monthly water-balance data were used to develop detailed water and sulfate mass-balance models to compute changes in sulfate load for each of six major storage compartments in response to precipitation, evaporation, inflow, and outflow from

  8. Boundary conditions for free surface inlet and outlet problems

    KAUST Repository

    Taroni, M.

    2012-08-10

    We investigate and compare the boundary conditions that are to be applied to free-surface problems involving inlet and outlets of Newtonian fluid, typically found in coating processes. The flux of fluid is a priori known at an inlet, but unknown at an outlet, where it is governed by the local behaviour near the film-forming meniscus. In the limit of vanishing capillary number Ca it is well known that the flux scales with Ca 2/3, but this classical result is non-uniform as the contact angle approaches π. By examining this limit we find a solution that is uniformly valid for all contact angles. Furthermore, by considering the far-field behaviour of the free surface we show that there exists a critical capillary number above which the problem at an inlet becomes over-determined. The implications of this result for the modelling of coating flows are discussed. © 2012 Cambridge University Press.

  9. The effects of mixing air distribution and heat load arrangement on the performance of ceiling radiant panels under cooling mode of operation

    DEFF Research Database (Denmark)

    Mustakallio, Panu; Kosonen, Risto; Melikov, Arsen Krikor

    2016-01-01

    arrangement and air distribution generated in a room by linear slot diffuser, radial multi-nozzle diffuser and radial swirl induction unit on the cooling power of radiant panels was compared. The impact on the thermal environment was also studied. Measurements were carried out without and with supply air...

  10. Antral hyperplastic polyp: A rare cause of gastric outlet obstruction.

    Science.gov (United States)

    Aydin, Ibrahim; Ozer, Ender; Rakici, Halil; Sehitoglu, Ibrahim; Yucel, Ahmet Fikret; Pergel, Ahmet; Sahin, Dursun Ali

    2014-01-01

    Gastric polyps are usually found incidentally during upper gastrointestinal endoscopic examinations. These polyps are generally benign, with hyperplasia being the most common. While gastric polyps are often asymptomatic, they can cause gastric outlet obstruction. A 64 years-old female patient presented to our polyclinic with a history of approximately 2 months of weakness, occasional early nausea, vomiting after meals and epigastric pain. A polypoid lesion of approximately 25mm in diameter was detected in the antral area of the stomach, which prolapsed through the pylorus into the duodenal bulbus, and subsequently caused gastric outlet obstruction, as revealed by upper gastrointestinal endoscopy of the patient. The polyp was retrieved from the pyloric canal into the stomach with the aid of a tripod, and snare polypectomy was performed. Currently, widespread use of endoscopy has led to an increase in the frequency of detecting hyperplastic polyps. While most gastric polyps are asymptomatic, they can cause iron deficiency anemia, acute pancreatitis and more commonly, gastric outlet obstruction because of their antral location. Although there are no precise principles in the treatment of asymptomatic polyps, polyps >5mm should be removed due to the possibility of malignant transformation. According to the medical evidence, polypectomy is required for gastric hyperplastic polyps because of the risks of complication and malignancy. These cases can be successfully treated endoscopically. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  11. Study on Gas Field Optimization Distribution with Parameters Adjustment of the Air Duct Outlet for Mechanized Heading Face in Coal Mine

    Science.gov (United States)

    Gong, Xiao-Yan; Zhang, Xin-Yi; Wu, Yue; Xia, Zhi-Xin; Li, Ying

    2017-12-01

    At present, as the increasingly drilling dimensions with cross-section expansion and distance prolong in coal mine, the situation of gas accumulation in mechanized heading face becomes severe. In this paper, optimization research of gas distribution was carried out by adjusting parameters of the air duct outlet, including angle, caliber and the front and rear distance of air duct outlet. Mechanized heading face of Ningtiaota coal mine was taken as the research object, simulated and analyzed the problems of original gas field, the reasonable parameters range of the air duct outlet was determined according to the allowable range of wind speed and the effect of gas dilution, the adjustment range of each parameter of the air duct outlet is preliminarily determined. Base on this, the distribution of gas field under different parameters adjustment of air duct outlet was simulated. The specific parameters under the different distance between the air duct outlet and the mechanized heading face were obtained, and a new method of optimizing the gas distribution by adjusting parameters of the air duct outlet was provided.

  12. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...

  13. Gas pressure in bubble attached to tube circular outlet

    OpenAIRE

    Salonen, A; Gay, Cyprien; Maestro, A; Drenckhan, W; Rio, Emmanuelle

    2016-01-01

    In the present Supplementary notes to our work ``Arresting bubble coarsening: A two-bubble experiment to investigate grain growth in presence of surface elasticity'' (accepted in EPL), we derive the expression of the gas pressure inside a bubble located above and attached to the circular outlet of a vertical tube.

  14. Utilization of Cupping Therapy in the Treatment of Vascular Thoracic Outlet Syndrome in a Collegiate Pitcher: A Case Study

    Directory of Open Access Journals (Sweden)

    Stephen A. Cage

    2017-12-01

    Full Text Available Objective: Present a clinical case detailing the effectiveness of dry cupping therapy in treating thoracic outlet syndrome. The utilization of dry cupping therapy on a 20-year-old collegiate baseball pitcher with diagnosed thoracic outlet syndrome is presented. Background: Thoracic outlet syndrome is a relatively rare musculoskeletal condition affecting 1/100,000 patients annually. Dry cupping therapy is an ancient therapeutic modality that utilizes various means of suction with the goal of decompressing myofascial layers. Treatment: Following diagnosis, patient was successfully treated in two weeks using dry cupping therapy. The patient experienced no further incidence of thoracic outlet syndrome symptoms and was able to complete the remainder of his competitive season. Uniqueness: The patient’s thoracic outlet syndrome was diagnosed at an early stage, leading to the need of clearance from a vascular specialist before returning to competition. To the author’s knowledge, there are currently no published case reports detailing the use of cupping therapy to treat thoracic outlet syndrome. Conclusion: Cupping therapy may be a viable treatment option when seeking to address tight musculature. Further research needs to be conducted to determine optimal parameters for cupping therapy as a therapeutic modality.

  15. Research on the Improvement of a Natural Gas Fired Burner for the CHP Application in a Central Heating Boiler using Radiant Burner Technology

    Energy Technology Data Exchange (ETDEWEB)

    Bieleveld, T.

    2010-08-15

    These days, the reduction of CO2 emissions from combustion devices is one of the main priorities for each design improvement. For the domestic use of the central heating boiler, Microgen Engine Corporation produces free piston Stirling engines for the Combined Heat and Power (CHP) application in these central heating boilers (Dutch: 'HRe ketel'). With CHP, the generation of electricity and heat are combined to increase overall efficiency, as heat is generally a waste product from the combustion to electric generation process. In this application, the Stirling engine, which can be defined as an external combustion engine, is heated by a natural gas fired engine-burner and cooled by a coolant flow. The heat transfer into the engine is converted into mechanical work and a heat flux from the engine. The mechanical work is used to produce electricity via a linear alternator. Heat in the flue gasses from the engine-burner is reused in a secondary burner and condensing heat exchanger. The coolant flow from the engine, after passing the secondary burner, is used for heating purposes. The heat transfer from engine-burner to the Stirling engine is analyzed and via several motivations it is found that it is favorable to improve fuel to electric conversion efficiency, for which the heat transfer efficiency of the engine-burner to the Stirling engine should be improved, as the engine design is not to be altered. From an initially developed linear free piston Stirling engine model and measurements performed at Microgen Engine Corporation, St. Petersborough, (UK), the engine power demand and engine-burner performance are found. The results are used to visualize the current energy flows of the Stirling engine and engine burner subsystem. The heat transfer to the engine is analyzed to find possible heat transfer improvements. It is concluded that heat transfer from the engine-burner to the engine can be approved if the flue losses due to convective heat transfer are

  16. 5 CFR 591.217 - In which outlets does OPM collect prices?

    Science.gov (United States)

    2010-01-01

    ... data collection areas, accessibility by road, physical size, advertising, and other characteristics that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets...

  17. Publication Outlets for School Psychology Faculty: 2010 to 2015

    Science.gov (United States)

    Hulac, David; Johnson, Natalie D.; Ushijima, Shiho C.; Schneider, Maryia M.

    2016-01-01

    Many school psychology faculty are required to publish for purposes of retention and promotion. It is useful to have an understanding of the different outlets for scholarly publications. In the present study, we investigated the peer-reviewed journals in which school psychology faculty were published between 2010 and 2015, the number of articles…

  18. Experimental investigation of the influence of the air jet trajectory on convective heat transfer in buildings equipped with air-based and radiant cooling systems

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2015-01-01

    -state and dynamic conditions. With the air-based cooling system, a dependency of the convective heat transfer on the air jet trajectory has been observed. New correlations have been developed, introducing a modified Archimedes number to account for the air flow pattern. The accuracy of the new correlations has been...... evaluated to±15%. Besides the study with an air-based cooling system, the convective heat transfer with a radiant cooling system has also been investigated. The convective flow at the activated surface is mainly driven by natural convection. For other surfaces, the complexity of the flow and the large......The complexity and diversity of airflow in buildings make the accurate definition of convective heat transfer coefficients (CHTCs) difficult. In a full-scale test facility, the convective heat transfer of two cooling systems (active chilled beam and radiant wall) has been investigated under steady...

  19. Outlet strut fracture of Björk-Shiley convexo-concave valves: can valve-manufacturing characteristics explain the risk?

    Science.gov (United States)

    Omar, R Z; Morton, L S; Beirne, M; Blot, W J; Lawford, P V; Hose, R; Taylor, K M

    2001-06-01

    Björk-Shiley 60 degrees convexo-concave prosthetic heart valves (Shiley, Inc, Irvine, Calif, a subsidiary of Pfizer, Inc) continue to be a concern for approximately 35,000 nonexplanted patients worldwide, with approximately 600 events reported to the manufacturer to date. Fractures of the outlet struts of the valves began to appear in the early 1980s and have continued to the present, but their causes are only partially understood. A matched case-control study was conducted evaluating manufacturing records for 52 valves with outlet strut fractures and 248 control subjects matched for age at implantation, valve size, and valve position. In addition to the risk factors recognized as determinants of outlet strut fracture, the United Kingdom case-control study has observed 7- to 9-fold increased risk with performance of multiple hook deflection tests. This test was performed more than once, usually after rework on the valve. Six valves in this study underwent multiple hook deflection tests, of which 4 experienced an outlet strut fracture. Cracks and further rework were noted for these valves. Significant associations were also observed between outlet strut fracture and disc-to-strut gap measurements taken before the attachment of the sewing ring. It is our view that a combination of factors related to valve design, manufacturing process, and patient characteristics are responsible for outlet strut fractures of Björk-Shiley convexo-concave valves. Multiple hook deflection tests have emerged as a potential new risk factor for outlet strut fracture in both The Netherlands and the United Kingdom. This factor appears to be correlated with the presence of other abnormalities. A further study is needed to investigate the factors correlated with multiple hook deflection tests. On confirmation of risk, the presence of multiple hook deflection tests may be added to equations, quantifying the risk of outlet strut fracture for comparison against risk of mortality and serious

  20. Using marine sediment archives to reconstruct past outlet glacier variability

    DEFF Research Database (Denmark)

    Andresen, Camilla Snowman; Straneo, Fiamma; Ribergaard, Mads

    2013-01-01

    Ice-rafted debris in fjord sediment cores provides information about outlet glacier activity beyond the instrumental time period. It tells us that the Helheim Glacier, Greenland’s third most productive glacier, responds rapidly to short-term (3 to 10 years) climate changes....

  1. Alcohol outlet densities and alcohol price: the British Columbia experiment in the partial privatization of alcohol sales off-premise.

    Science.gov (United States)

    Treno, Andrew J; Ponicki, William R; Stockwell, Tim; Macdonald, Scott; Gruenewald, Paul J; Zhao, Jinhui; Martin, Gina; Greer, Alissa

    2013-05-01

    Alcohol beverage prices or taxes have been shown to be related to alcohol sales and use and related problems. What is not clear are the mechanisms underlying these relationships. This study examines the relationship between alcohol outlet density under conditions of the partial privatization of off-premise consumption in British Columbia (BC) occurring over the past decade. Two hypotheses are tested. First, reflecting basic supply-demand principles, greater geographic densities of alcohol outlets will be directly related to reductions in beverage prices in response to greater competition. Second, reflecting the effects of niche marketing and resulting market stratification, increased densities of private liquor stores will be especially related to reductions in beverage prices within this outlet category. Data were collected from: (i) a survey of BC private store prices and practices, (ii) alcohol outlet location information, and (iii) data on demographic characteristics. Multilevel models examine the relationships between prices at individual private liquor stores and the densities of government liquor stores, private liquor stores, bars, and restaurants, controlling for background demographics and geographic unit level effects. Spatial dependencies were also examined. Increased densities of private liquor stores were associated with lower mean prices of beer and all alcohol aggregated across brands at the store level. There appeared to be no outlet level effect on discounting patterns, however, with the mean price differences apparently reflecting differences in the quality of brands carried rather than unequal prices for any given brand. Increased densities of private off-sale alcohol outlets appear to result in lower prices charged at said establishments independently of other types of alcohol outlets suggesting that they represent an emerging marketing niche in the context of off-sale outlet privatization. Copyright © 2012 by the Research Society on

  2. Experimental and modelling analysis of an office building HVAC system based in a ground-coupled heat pump and radiant floor

    International Nuclear Information System (INIS)

    Villarino, José Ignacio; Villarino, Alberto; Fernández, Francisco Ángel

    2017-01-01

    Highlights: • A case study of a geothermal heat pump in an office building. • A numerical model in EnergyPlus is validated by experimental results. • An energy, economic and environmental analysis is presented. • A comparison with other technologies demonstrates the potential of the system. - Abstract: This paper shows the evaluation of the performance of a ground-coupled heat pump system monitored building providing heating, ventilating and air conditioning to an office building located in Madrid, in Spain. The system consists of one borehole exchanger, heat pump unit, radiant floor system, mechanical ventilation and data control system. A simulation model was performed with EnergyPlus software and validated. The analyzed period corresponds to the most unfavorable weather conditions in heating and cooling mode. The coefficient of performance obtained in heating and cooling mode was 3.86/5.29, considering all the energy consumption elements of the building and the thermal demand corresponding to an office operation. The CO_2 emissions obtained with a value of 34.68 kg corresponding to the period analyzed represents a low CO_2 emission system. The monitored temperatures reached set point values of 22 °C/25 °C, considered as acceptable comfort temperatures. The values obtained in the validated simulation model presented a deviation of 2% respected experimental results in heating and cooling mode. A comparative of COP_s_y_s and CO_2 emissions with other technologies is performed in order to analyze GCHP compared to other available technologies. The GCHP system is presented as a technology that can fully supply the HVAC conditions for a building and environmentally friendly.

  3. Predictive factors of bladder outlet obstruction following the tension ...

    African Journals Online (AJOL)

    H. Elghamrawi

    On the other hand, multivariate analysis indicated that Qmax was the only factor independently related to postoperative bladder outlet obstruction after TVTO (p = 0.002, odds ratio = 0.658, 95% CI for odds ratio 0.507–0.855). Discussion. Stress urinary incontinence defined as the involuntary loss of urine during increases in ...

  4. Consideration of hot channel factors in design for providing operating margins on coolant channel outlet temperature

    International Nuclear Information System (INIS)

    Sharma, V.K.; Surendar, C.; Bapat, C.N.

    1994-01-01

    The Indian Pressurized Heavy Water Reactors (IPHWR) are horizontal pressure tube reactors using natural uranium oxide fuel in the form of short (495 mm) clusters. The fuel clusters in the Zr-Nb pressure tubes are cooled by high pressure, high temperature and subcooled circulating heavy water. Coolant flow distribution to individual channels is designed to match the power distribution so as to obtain uniform coolant outlet temperature. However, during operation, the coolant outlet temperature in individual channels deviate from their nominal value due to: tolerances in process design; effects of grid frequency on the pump speed; deviation in channel powers from the nominal values due to on-power fuelling and movement of reactivity devices, and so on. Thus an operating margin, between the highest permissible and nominal coolant outlet temperatures, is required taking into account various hot channel factors that contribute to higher coolant outlet temperatures. The paper discusses the methodology adopted to assess various hot channel factors which would provide optimum operating margins while ensuring sub-cooling. (author)

  5. Map-based prediction of organic carbon in headwater streams improved by downstream observations from the river outlet

    Science.gov (United States)

    Temnerud, J.; von Brömssen, C.; Fölster, J.; Buffam, I.; Andersson, J.-O.; Nyberg, L.; Bishop, K.

    2016-01-01

    In spite of the great abundance and ecological importance of headwater streams, managers are usually limited by a lack of information about water chemistry in these headwaters. In this study we test whether river outlet chemistry can be used as an additional source of information to improve the prediction of the chemistry of upstream headwaters (size interquartile range (IQR)) of headwater stream TOC for a given catchment, based on a large number of candidate variables including sub-catchment characteristics from GIS, and measured river chemistry at the catchment outlet. The best candidate variables from the PLS models were then used in hierarchical linear mixed models (MM) to model TOC in individual headwater streams. Three predictor variables were consistently selected for the MM calibration sets: (1) proportion of forested wetlands in the sub-catchment (positively correlated with headwater stream TOC), (2) proportion of lake surface cover in the sub-catchment (negatively correlated with headwater stream TOC), and (3) river outlet TOC (positively correlated with headwater stream TOC). Including river outlet TOC improved predictions, with 5-15 % lower prediction errors than when using map information alone. Thus, data on water chemistry measured at river outlets offer information which can complement GIS-based modelling of headwater stream chemistry.

  6. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    International Nuclear Information System (INIS)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R.

    2005-01-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310 o C with up to 0.30 steam voidage, turns through 90 o as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73 o bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside of the bend, where a CFD

  7. Flow visualization study of two phase flow in a single bend outlet feeder pipe and horizontal annulus of outlet end-fitting of a CANDU reactor

    Energy Technology Data Exchange (ETDEWEB)

    Supa-Amornkul, S.; Lister, D.H.; Steward, F.R. [Univ. of New Brunswick, Fredericton, New Brunswick (Canada)]. E-mail: h796e@unb.ca; dlister@unb.ca; fsteward@unb.ca

    2005-07-01

    'Full text:' In CANDU-6 reactors, the pressurized high-temperature coolant flows through 380 fuel channels passing horizontally through the core. Each end of a fuel channel has a stainless steel annular end-fitting connected to a carbon steel feeder pipe. The outlet coolant, which is at 310{sup o}C with up to 0.30 steam voidage, turns through 90{sup o} as it passes from flow in the annular end-fitting to pipe flow in the feeder via a Grayloc connector. Since 1996, several CANDU stations have reported excessive corrosion of their outlet feeder pipes; especially between the first metre, which consisted of single or double bends. Early studies related the attack to the hydrodynamics of the coolant and verified that it was a type of flow accelerated corrosion. In order to understand the hydrodynamics of the coolant in the outlet feeders by flow-visualization, a full-scale transparent test section simulating the geometry and orientation of an outlet feeder bend with its upstream annular end-fitting were fabricated. The feeder consisted of a 54 mm inside diameter acrylic pipe with a 73{sup o} bend, connecting to an acrylic simulation of a Grayloc flanged fitting and annular end-fitting. The annular end-fitting consisted of an inner pipe, 110 mm outer diameter, and an outer pipe, 150 mm inner diameter, both 190.7 cm long in length. The tests were performed with water and air at atmospheric pressure and room temperature. The maximum water volumetric flow rate was 19 L/s and the volume fraction of air varied from 0.05 to 0.56. The phase distributions within the feeder pipe and along the length of the annulus were investigated with a digital video recorder. Size, concentration and velocity of the air bubbles at particular locations were studied with a high-speed digital still camera and a high-speed digital video camera. Phase distributions and variations in bubble size with velocity were determined. Particular attention was paid to the flow pattern at the inside

  8. R/S analysis based study on long memory about CODMn in Poyang Lake Inlet and Outlet

    Science.gov (United States)

    Wang, Lili

    2018-02-01

    Rescaled range analysis (R/S) is applied to the long memory behavior analysis of water CODMn series in Poyang Lake Inlet and Outlet in China. The results show that these CODMn series are characterized by long memory, and the characteristics have obvious differences between the Lake Inlet and Outlet. Our findings suggest that there was an obvious scale invariance, namely CODMn series in Lake Inlet for 13 weeks and CODMn in Lake Outlet for 17 weeks. Both displayed a two-power-law distribution and a similar high long memory. We made a preliminary explanation for the existence of the boundary point tc , using self-organized criticality. This work can be helpful to improvement of modelling of lake water quality.

  9. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  10. Design and construction of a regenerative radiant tube burner

    International Nuclear Information System (INIS)

    Henao, Diego Alberto; Cano C, Carlos Andres; Amell Arrieta, Andres A.

    2002-01-01

    The technological development of the gas industry in Colombia, aiming at efficient and safe use of the natural gas, requires the assimilation and adaptation of new generation, technologies for this purpose in this article results are presented on the design, construction and characterization of a prototype of a burner of regenerative radiant robe with a thermal power of 9,94 kW and a factor of air 1,05. This system takes advantage of the high exit temperature of the combustion smokes, after they go trough a metallic robe where they transfer the heat by radiation, to heat a ceramic channel that has the capacity to absorbing a part of the heat of the smokes and then transferring them to a current of cold air. The benefits of air heating are a saving in fuel, compared with other processes that don't incorporate the recovery of heat from the combustion gases. In this work it was possible to probe a methodology for the design of this type of burners and to reach maximum temperatures of heating of combustion air of 377,9 centigrade degrees, using a material available in the national market, whose regenerative properties should be studied in depth

  11. Survey of Publication Outlets in Early Childhood Education: Descriptive Data, Review Processes, and Advice to Authors

    Science.gov (United States)

    Amodei, Michelle L.; Jalongo, Mary Renck; Myers, Jacqueline; Onchwari, Jacqueline; Gargiulo, Richard M.

    2013-01-01

    Publishing outlets in the field of early childhood vary widely in terms of emphasis on theory, practice, and research as they relate to the care and education of the very young; these outlets also have different readerships (i.e., primarily for teachers, the teachers of their teachers, or the fellow scholars/researchers). Included in the mixture…

  12. Effect of spacer grid mixing vanes on coolant outlet temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Raemae, Tommi; Lahtinen, Tuukka; Brandt, Tellervo; Toppila, Timo [Fortum Power and Heat, Fortum (Finland). Nuclear Competence Center

    2012-08-15

    In Loviisa VVER-440-type NPP the coolant outlet temperature of the hot subchannel is constantly monitored during the operation. According to the authority requirement the maximum subchannel outlet temperature must not exceed the saturation temperature. Coolant temperature distribution inside the fuel assembly is affected by the efficiency of the coolant mixing. In order to enhance the coolant mixing the fuel manufacturer is introducing the additional mixing vanes on the fuel bundle spacer grids. In the paper the effect of the different mixing vane modifications is studied with computational fluid dynamics (CFD) simulation. Goal of the modelling is to find vane modifications with which sufficient mixing is reached with acceptable increase in the spacer grid pressure loss. The results of the studies are discussed in the paper. (orig.)

  13. Simulation of Solar Energy Use in Livelihood of Buildings

    Science.gov (United States)

    Lvocich, I. Ya; Preobrazhenskiy, A. P.; Choporov, O. N.

    2017-11-01

    Solar energy can be considered as the most technological and economical type of renewable energy. The purpose of the paper is to increase the efficiency of solar energy utilization on the basis of the mathematical simulation of the solar collector. A mathematical model of the radiant heat transfer vacuum solar collector is clarified. The model was based on the process of radiative heat transfer between glass and copper walls with the defined blackness degrees. A mathematical model of the ether phase transition point is developed. The dependence of the reservoir walls temperature change on the ambient temperature over time is obtained. The results of the paper can be useful for the development of prospective sources using solar energy.

  14. A cross sectional study investigating the association between exposure to food outlets and childhood obesity in Leeds, UK.

    Science.gov (United States)

    Griffiths, Claire; Frearson, Anna; Taylor, Adam; Radley, Duncan; Cooke, Carlton

    2014-12-06

    Current UK policy in relation to the influence of the 'food environment' on childhood obesity appears to be driven largely on assumptions or speculations because empirical evidence is lacking and findings from studies are inconsistent. The aim of this study was to investigate the number of food outlets and the proximity of food outlets in the same sample of children, without solely focusing on fast food. Cross sectional study over 3 years (n = 13,291 data aggregated). Body mass index (BMI) was calculated for each participant, overweight and obesity were defined as having a BMI >85(th) (sBMI 1.04) and 95(th) (sBMI 1.64) percentiles respectively (UK90 growth charts). Home and school neighbourhoods were defined as circular buffers with a 2 km Euclidean radius, centred on these locations. Commuting routes were calculated using the shortest straight line distance, with a 2 km buffer to capture varying routes. Data on food outlet locations was sourced from Leeds City Council covering the study area and mapped against postcode. Food outlets were categorised into three groups, supermarkets, takeaway and retail. Proximity to the nearest food outlet in the home and school environmental domain was also investigated. Age, gender, ethnicity and deprivation (IDACI) were included as covariates in all models. There is no evidence of an association between the number of food outlets and childhood obesity in any of these environments; Home Q4 vs. Q1 OR = 1.11 (95% CI = 0.95-1.30); School Q4 vs. Q1 OR = 1.00 (95% CI 0.87 - 1.16); commute Q4 vs. Q1 OR = 0.1.00 (95% CI 0.83 - 1.20). Similarly there is no evidence of an association between the proximity to the nearest food outlet and childhood obesity in the home (OR = 0.77 [95% CI = 0.61 - 0.98]) or the school (OR = 1.01 [95% CI 0.84 - 1.23]) environment. This study provides little support for the notion that exposure to food outlets in the home, school and commuting neighbourhoods increase the risk of obesity

  15. Influencia del tiempo de explotación del Láser de CO2 y la cantidad de ventiladores del Sistema de Enfriamiento sobre la estabilidad del flujo radiante a la salida del Sistema Láser SYNRAD 48-2. // The Influences of the time of exploitation of the Laser o

    Directory of Open Access Journals (Sweden)

    V. Ramirez Chi

    2002-09-01

    Full Text Available En el diseño de un Sistema Láser para ser utilizado con fines médicos, un aspecto a tener en cuenta por su importancia es lagarantía de lograr un Sistema de Ventilación que implique mantener estable el flujo radiante de láser a la salida del equipodurante el período de explotación. En el Centro Nacional de Investigaciones Científicas (CENIC se han hechoinvestigaciones en estos equipos de Sistemas Láser con el objetivo de determinar en que medida influyen la cantidad deventiladores dispuestos sobre el flujo radiante del láser a la salida del equipo de Láser de CO2 y el tiempo de explotacióndel equipo sobre la estabilidad del flujo radiante del láser de salida. Mediante la modelación, la simulación, el Diseño deExperimento y métodos estadísticos se determinó que el tiempo de explotación del equipo durante cada intervenciónmédica y la cantidad de ventiladores implican una influencia significativa sobre la estabilidad del flujo radiante de salida.Esta investigación se llevó a cabo en el equipo de Láser de CO2 SYNRAD 48-2 y se empleó en la misma el programa decomputación para el Diseño de Experimentos Statgrafics-Plus.Palabras claves: Láser, flujo radiante.____________________________________________________________________AbstractIn the design of a Laser System/s to be used with ends doctors, an aspect to keep in mind for its importance is the guaranteeof achieving a System of Ventilation that implies to maintain stable the radiant flow of exit of the Laser during the periodof exploitation. In the CENIC investigations have been made in these Laser System/s with the objective of determining inthat measured they influence the quantity of willing fans about the radiant flow of exit of the Laser of CO2 and the time ofexploitation of the Laser about the stability of the radiant flow of exit. By means of the modelación, the simulation, theDesign of Experiment and statistical methods were determined that the time of

  16. Associations between major chain fast-food outlet availability and change in body mass index: a longitudinal observational study of women from Victoria, Australia.

    Science.gov (United States)

    Lamb, Karen E; Thornton, Lukar E; Olstad, Dana Lee; Cerin, Ester; Ball, Kylie

    2017-10-16

    The residential neighbourhood fast-food environment has the potential to lead to increased levels of obesity by providing opportunities for residents to consume energy-dense products. This longitudinal study aimed to examine whether change in body mass index (BMI) differed dependent on major chain fast-food outlet availability among women residing in disadvantaged neighbourhoods. Eighty disadvantaged neighbourhoods in Victoria, Australia. Sample of 882 women aged 18-46 years at baseline (wave I: 2007/2008) who remained at the same residential location at all three waves (wave II: 2010/2011; wave III: 2012/2013) of the Resilience for Eating and Activity Despite Inequality study. BMI based on self-reported height and weight at each wave. There was no evidence of an interaction between time and the number of major chain fast-food outlets within 2 (p=0.88), 3 (p=0.66) or 5 km (p=0.24) in the multilevel models of BMI. Furthermore, there was no evidence of an interaction between time and change in availability at any distance and BMI. Change in BMI was not found to differ by residential major chain fast-food outlet availability among Victorian women residing in disadvantaged neighbourhoods. It may be that exposure to fast-food outlets around other locations regularly visited influence change in BMI. Future research needs to consider what environments are the key sources for accessing and consuming fast food and how these relate to BMI and obesity risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Effect of Set-point Variation on Thermal Comfort and Energy Use in a Plus-energy Dwelling

    DEFF Research Database (Denmark)

    Toftum, Jørn; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2016-01-01

    When designing buildings and space conditioning systems, the occupant thermal comfort, health, and productivity are the main criteria to satisfy. However, this should be achieved with the most energy-efficient space conditioning systems (heating, cooling, and ventilation). Control strategy, set......-points, and control dead-bands have a direct effect on the thermal environment in and the energy use of a building. The thermal environment in and the energy use of a building are associated with the thermal mass of the building and the control strategy, including set-points and control dead-bands. With thermally...... active building systems (TABS), temperatures are allowed to drift within the comfort zone, while in spaces with air-conditioning, temperatures in a narrower interval typically are aimed at. This behavior of radiant systems provides certain advantages regarding energy use, since the temperatures...

  18. A critical examination of the validity of simplified models for radiant heat transfer analysis.

    Science.gov (United States)

    Toor, J. S.; Viskanta, R.

    1972-01-01

    Examination of the directional effects of the simplified models by comparing the experimental data with the predictions based on simple and more detailed models for the radiation characteristics of surfaces. Analytical results indicate that the constant property diffuse and specular models do not yield the upper and lower bounds on local radiant heat flux. In general, the constant property specular analysis yields higher values of irradiation than the constant property diffuse analysis. A diffuse surface in the enclosure appears to destroy the effect of specularity of the other surfaces. Semigray and gray analyses predict the irradiation reasonably well provided that the directional properties and the specularity of the surfaces are taken into account. The uniform and nonuniform radiosity diffuse models are in satisfactory agreement with each other.

  19. Procedure for prolapse and hemorrhoids vs traditional surgery for outlet obstructive constipation.

    Science.gov (United States)

    Lu, Ming; Yang, Bo; Liu, Yang; Liu, Qing; Wen, Hao

    2015-07-14

    To compare the clinical efficacies of two surgical procedures for hemorrhoid rectal prolapse with outlet obstruction-induced constipation. One hundred eight inpatients who underwent surgery for outlet obstructive constipation caused by internal rectal prolapse and circumferential hemorrhoids at the First Affiliated Hospital of Xinjiang Medical University from June 2012 to June 2013 were prospectively included in the study. The patients with rectal prolapse hemorrhoids with outlet obstruction-induced constipation were randomly divided into two groups to undergo either a procedure for prolapse and hemorrhoids (PPH) (n = 54) or conventional surgery (n = 54; control group). Short-term (operative time, postoperative hospital stay, postoperative urinary retention, postoperative perianal edema, and postoperative pain) and long-term (postoperative anal stenosis, postoperative sensory anal incontinence, postoperative recurrence, and postoperative difficulty in defecation) clinical effects were compared between the two groups. The short- and long-term efficacies of the two procedures were determined. In terms of short-term clinical effects, operative time and postoperative hospital stay were significantly shorter in the PPH group than in the control group (24.36 ± 5.16 min vs 44.27 ± 6.57 min, 2.1 ± 1.4 d vs 3.6 ± 2.3 d, both P hemorrhoids.

  20. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  1. Turbofan gas turbine engine with variable fan outlet guide vanes

    Science.gov (United States)

    Wood, Peter John (Inventor); LaChapelle, Donald George (Inventor); Grant, Carl (Inventor); Zenon, Ruby Lasandra (Inventor); Mielke, Mark Joseph (Inventor)

    2010-01-01

    A turbofan gas turbine engine includes a forward fan section with a row of fan rotor blades, a core engine, and a fan bypass duct downstream of the forward fan section and radially outwardly of the core engine. The forward fan section has only a single stage of variable fan guide vanes which are variable fan outlet guide vanes downstream of the forward fan rotor blades. An exemplary embodiment of the engine includes an afterburner downstream of the fan bypass duct between the core engine and an exhaust nozzle. The variable fan outlet guide vanes are operable to pivot from a nominal OGV position at take-off to an open OGV position at a high flight Mach Number which may be in a range of between about 2.5-4+. Struts extend radially across a radially inwardly curved portion of a flowpath of the engine between the forward fan section and the core engine.

  2. Gastric Adenocarcinoma Presenting with Gastric Outlet Obstruction in a Child

    Directory of Open Access Journals (Sweden)

    Abdulrahman Al-Hussaini

    2014-01-01

    Full Text Available Gastric carcinoma is extremely rare in children representing only 0.05% of all gastrointestinal malignancies. Here, we report the first pediatric case of gastric cancer presenting with gastric outlet obstruction. Upper endoscopy revealed a markedly thickened antral mucosa occluding the pylorus and a clean base ulcer 1.5 cm × 2 cm at the lesser curvature of the stomach. The narrowed antrum and pylorus underwent balloon dilation, and biopsy from the antrum showed evidence of Helicobacter pylori gastritis. The biopsy taken from the edge of the gastric ulcer demonstrated signet-ring-cell type infiltrate consistent with gastric adenocarcinoma. At laparotomy, there were metastases to the liver, head of pancreas, and mesenteric lymph nodes. Therefore, the gastric carcinoma was deemed unresectable. The patient died few months after initiation of chemotherapy due to advanced malignancy. In conclusion, this case report underscores the possibility of gastric adenocarcinoma occurring in children and presenting with gastric outlet obstruction.

  3. The impact of inlet angle and outlet angle of guide vane on pump in reversal based hydraulic turbine performance

    International Nuclear Information System (INIS)

    Shi, F X; Yang, J H; Wang, X H; Zhang, R H; Li, C E

    2012-01-01

    In this paper, in order to research the impact of inlet angle and outlet angle of guide vane on hydraulic turbine performance, a centrifugal pump in reversal is adopted as turbine. A numerical simulation method is adopted for researching outer performance and flow field of turbine. The results show: inlet angle has a crucial role to turbine, to the same flow, there is a noticeable decline for the efficiency and head of turbine with the inlet angle increases. At the best efficiency point(EFP),to a same inlet angle, when the inlet angle greater than inlet angle, velocity circulation in guide vane outlet decreases, which lead the efficiency of turbine to reduce, Contrarily, the efficiency rises. With the increase of inlet angle and outlet angle, the EFP moves to the big flow area and the uniformity of pressure distribution becomes worse. The paper indicates that the inlet angle and outlet angle have great impact on the turbine performance, and the best combination exists for the inlet angle and outlet angle of the guide vane.

  4. Study on the natural air cooling design of electronic equipment casings: Effects of the height and size of outlet vent on the flow resistances

    International Nuclear Information System (INIS)

    Ishizuka, M; Hatakeyama, T; Kibushi, R; Inoue, M

    2012-01-01

    This paper describes the effects of the outlet vent size and the distance between the outlet vent location and the power heater position on the flow resistance in natural-air-cooled electronic equipment casings. An experiment was carried out using a simple model casing simulated for the practical natural-air-cooled casing which is composed of 4 side walls, a top plate and bottom plate which has an inlet opening. A power heater to served as a power dissipation unit was placed at its open bottom. An outlet opening was set on one of the side walls. The opening area, the height of the outlet and the heater location were varied. The experimental results were analyzed using the flow resistance coefficient K which was related to the distance between the outlet vent and the power heater position and the heat removal from the outlet vent, and K values were plotted against a pair of Reynolds numbers Re and the outlet vent porosity β which is defined as the ratio of outlet vent open area to the top surface area of the casing.

  5. Report of an adult with double-outlet right ventricle

    International Nuclear Information System (INIS)

    Munera E, Ana G; Florez C, Marina; Delgado de B, Jorge A and others

    2001-01-01

    The case of a 22 -year- old woman with a diagnosis of congenital heart disease, N Y H A class I, who complaints palpitations. By echocardiography, angiography and magnetic resonance imaging a diagnosis of double-outlet right ventricle was done. She was intervened for correction, creating an interventricular tunnel connecting the left ventricle to the aorta through the ventricular septal defect

  6. Albanian and UK Consumers’ Perceptions of Farmers’ Markets and Supermarkets as Outlets for Organic Food: An Exploratory Study

    Directory of Open Access Journals (Sweden)

    Athina-Evera Qendro

    2015-05-01

    Full Text Available The purpose of this paper is to elicit UK and Albanian consumers’ perceptions of food outlets in order to understand their views on supermarkets and farmers’ markets as outlets for organic food. A qualitative research methodology was chosen as the best way to get an in-depth understanding of how consumers of these two different countries understand and evaluate buying organic food from two different food outlets. This exploratory research is a first step to find out how and why organic food is being bought in supermarkets and farmers’ markets. The results show that respondents associated organic with vegetables and fruit, that taste good, are healthy, and are free of pesticides and hormones. The importance of motives varies between the outlets they prefer for buying organic food. An interesting finding is the fact that Albanian respondents refer to the farmers’ markets as the villagers’ market.

  7. Experimental investigation and feasibility analysis on a capillary radiant heating system based on solar and air source heat pump dual heat source

    International Nuclear Information System (INIS)

    Zhao, M.; Gu, Z.L.; Kang, W.B.; Liu, X.; Zhang, L.Y.; Jin, L.W.; Zhang, Q.L.

    2017-01-01

    Graphical abstract: (a) Vertical temperature gradient in Case 3, (b) PMV and PPD of the test room in Case 3, (c) operating time of SPCTS and ASHP systems in Case 3 and (d) the proportion of SPCTS operating time. - Highlights: • A capillary heating system based on solar and air source heat pump was developed. • Influence of supply water temperature on solar energy saving rate was investigated. • Heating performance and thermal comfort of capillary heating system were analyzed. • Low temperature heating with capillary is suitable for solar heating system. - Abstract: Due to sustainable development, solar energy has drawn much attention and been widely applied in buildings. However, the application of solar energy is limited because of its instability, intermittency and low energy density in winter. In order to use low density and instable solar energy source for heating and improve the utilization efficiency of solar energy, a solar phase change thermal storage (SPCTS) heating system using a radiant-capillary-terminal (RCT) to effectively match the low temperature hot water, a phase change thermal storage (PCTS) to store and continuously utilize the solar energy, and an air source heat pump (ASHP) as an alternate energy, was proposed and set up in this research. Series of experiments were conducted to obtain the relation between the solar radiation utilization rate and the heating supply temperatures, and to evaluate the performance of the RCT module and the indoor thermal environment of the system for its practical application in a residential building in the north-western City of Xi’an, China. The results show that energy saving of the solar heating system can be significantly improved by reducing the supplied water temperature, and the supplied water temperature of the RCT would be no more than 35 °C. The capillary radiation heating can adopt a lower water temperature and create a good thermal comfort environment as well. These results may lead to the

  8. Vendor-to-vendor education to improve malaria treatment by private drug outlets in Bungoma District, Kenya

    Directory of Open Access Journals (Sweden)

    Makama Sammy

    2003-05-01

    Full Text Available Abstract Background Private outlets are the main suppliers of uncomplicated malaria treatment in Africa. However, they are so numerous that they are difficult for governments to influence and regulate. This study's objective was to evaluate a low-cost outreach education (vendor-to-vendor programme to improve the private sector's compliance with malaria guidelines in Bungoma district, Kenya. The cornerstone of the programme was the district's training of 73 wholesalers who were equipped with customized job aids for distribution to small retailers. Methods Six months after training the wholesalers, the programme was evaluated using mystery shoppers. The shoppers posed as caretakers of sick children needing medication at 252 drug outlets. Afterwards, supervisors assessed the outlets' knowledge, drug stocks, and prices. Results The intervention seems to have had a significant impact on stocking patterns, malaria knowledge and prescribing practices of shops/kiosks, but not consistently on other types of outlets. About 32% of shops receiving job aids prescribed to mystery shoppers the approved first-line drug, sulfadoxine-pyremethamine, as compared to only 3% of the control shops. In the first six months, it is estimated that 500 outlets were reached, at a cost of about $8000. Conclusions Changing private sector knowledge and practices is widely acknowledged to be slow and difficult. The vendor-to-vendor programme seems a feasible district-level strategy for achieving significant improvements in knowledge and practices of shops/kiosks. However, alternate strategies will be needed to influence pharmacies and clinics. Overall, the impact will be only moderate unless national policies and programmes are also introduced.

  9. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele.

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-02-01

    BACKGROUND The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. MATERIAL AND METHODS Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. RESULTS Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. CONCLUSIONS For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR.

  10. Transvaginal Mesh and Transanal Resection to Treat Outlet Obstruction Constipation Caused by Rectocele

    Science.gov (United States)

    Shi, Yang; Yu, Yongjun; Zhang, Xipeng; Li, Yuwei

    2017-01-01

    Background The aim of this study was to evaluate the curative effect of transvaginal mesh repair (TVMR) and stapled transanal rectal resection (STARR) in treating outlet obstruction constipation caused by rectocele. Material/Methods Patients who had outlet obstruction constipation caused by rectocele were retrospectively analyzed and 39 patients were enrolled the study. Patients were assigned to either the TVMR or STARR group. Postoperative factors such as complications, pain, recurrence rate, and operative time were compared between the 2 groups. Results Total effective rate was 100% in both groups. No long-term chronic pain occurred and discomfort rate of tenesmus was higher in the STARR group than in the TVMR group. Postoperative defecography showed that the rectocele depth was significantly reduced, and the prolapse of the rectal mucosa and the lower rectal capacity was also decreased. Four cases had mesh exposure in the TVMR group and 2 cases in the STARR group had anastomotic bleeding after the surgery. Conclusions For outlet obstruction constipation caused by rectocele, TVMR and STARR both obtained satisfactory results. Although TVMR is complex with longer operative time and hospitalization period, its long-term effect is better than that of STARR. PMID:28146137

  11. Tobacco retail outlet restrictions: health and cost impacts from multistate life-table modelling in a national population.

    Science.gov (United States)

    Pearson, Amber L; Cleghorn, Christine L; van der Deen, Frederieke S; Cobiac, Linda J; Kvizhinadze, Giorgi; Nghiem, Nhung; Blakely, Tony; Wilson, Nick

    2016-09-22

    Since there is some evidence that the density and distribution of tobacco retail outlets may influence smoking behaviours, we aimed to estimate the impacts of 4 tobacco outlet reduction interventions in a country with a smoke-free goal: New Zealand (NZ). A multistate life-table model of 16 tobacco-related diseases, using national data by sex, age and ethnicity, was used to estimate quality-adjusted life years (QALYs) gained and net costs over the remainder of the 2011 NZ population's lifetime. The outlet reduction interventions assumed that increased travel costs can be operationalised as equivalent to price increases in tobacco. All 4 modelled interventions led to reductions of >89% of current tobacco outlets after the 10-year phase-in process. The most effective intervention limited sales to half of liquor stores (and nowhere else) at 129 000 QALYs gained over the lifetime of the population (95% UI: 74 100 to 212 000, undiscounted). The per capita QALY gains were up to 5 times greater for Māori (indigenous population) compared to non-Māori. All interventions were cost-saving to the health system, with the largest saving for the liquor store only intervention: US$1.23 billion (95% UI: $0.70 to $2.00 billion, undiscounted). These tobacco outlet reductions reduced smoking prevalence, achieved health gains and saved health system costs. Effects would be larger if outlet reductions have additional spill-over effects (eg, smoking denormalisation). While these interventions were not as effective as tobacco tax increases (using the same model), these and other strategies could be combined to maximise health gain and to maximise cost-savings to the health system. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Fruit and vegetable intake in adolescents: SES and exposure to supermarkets and fast food outlets

    DEFF Research Database (Denmark)

    Svastisalee, Chalida; Holstein, Bjørn Evald; Due, Pernille

    backgrounds. Methods Data from the Health Behavior in School Aged Children Study (n = 6,034) were supplemented with geocoded information regarding supermarkets and fast food outlets, 300 meters from each school (n = 80). We used multilevel logistic regression to examine the relationship between infrequent...... fruit and vegetable intake and supermarket and fast food outlet concentration, stratifying by levels of family social class. Results Examining supermarket exposure alone, children from low social class backgrounds had the greatest odds of infrequent vegetable (OR = 1.50; CI: 1.03-2.20) and fruit (OR = 1.......43;CI: 1.06-1.93) intake, attending schools with low concentration of supermarkets. Children from low social class families attending schools with high fast food outlet and low supermarket concentration had the greatest odds of infrequent vegetable (OR = 1.79;CI: 0.99-3.21) and fruit (OR = 1.59; CI: 1...

  13. Direct evaluation of reflector effects on radiant flux from InGaN-based light-emitting diodes

    Science.gov (United States)

    Masui, Hisashi; Fellows, Natalie N.; Sato, Hitoshi; Asamizu, Hirokuni; Nakamura, Shuji; Denbaars, Steven P.

    2007-08-01

    A metal layer formed on the backside of InGaN/sapphire-based light-emitting diodes deteriorates the inherent optical power output. An experimental approach of a suspended die is employed to study the effects of such metal layers via a direct comparison in radiant flux from a discrete die with and without a reflector. A sphere package that employs no reflector is proposed and fabricated. Light extraction of the sphere design is discussed; a light source in the sphere package would not have to be either an ideal point or placed at the center of the sphere, due to a finite critical angle at the sphere/air interface.

  14. Improvement of life and NO{sub x} emission of radiant tube heating system by elastic-plastic creep analysis; Dansosei kuripu kaiseki ni yoru hosha dennetsukan kanetsu shisutemu no jumyo to NO{sub x} haishutsuryo no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Tsuguhiko; Nuta, Kunihiro [Kawasaki Steel Corp., Okayama, (Japan). Mizushima Warks

    1999-03-10

    The radiant tube heating system has been widely applied to the furnaces which require isolation of the heating atmosphere from the combustion atmosphere. However, the conventional system has a short life and it is difficult to reduce NO{sub x} emission when it is used at a high furnace temperature under high combustion load, because the fuel is burned in a small space. In order to solve this problem, we have studied the cause of radiant tube life depends on the uniformity of the temperature distribution along the radiant tube. We have developed a new burner using a two-stage combustion method with exhaust gas self-recirculation. As a result, the file of the new system has been increased by a factor of two or more, and NO{sub x} emission has been reduced by 20 % from previous levels. This paper presents an outline of the elastic-plastic creep analysis and the new burner, and describes the effect of its use on system life. (author)

  15. Is the number of fast-food outlets in the neighbourhood related to screen-detected type 2 diabetes mellitus and associated risk factors?

    Science.gov (United States)

    Bodicoat, Danielle H; Carter, Patrice; Comber, Alexis; Edwardson, Charlotte; Gray, Laura J; Hill, Sian; Webb, David; Yates, Thomas; Davies, Melanie J; Khunti, Kamlesh

    2015-06-01

    We investigated whether a higher number of fast-food outlets in an individual's home neighbourhood is associated with increased prevalence of type 2 diabetes mellitus and related risk factors, including obesity. Cross-sectional study. Three UK-based diabetes screening studies (one general population, two high-risk populations) conducted between 2004 and 2011. The primary outcome was screen-detected type 2 diabetes. Secondary outcomes were risk factors for type 2 diabetes. In total 10 461 participants (mean age 59 years; 53% male; 21% non-White ethnicity). There was a higher number of neighbourhood (500 m radius from home postcode) fast-food outlets among non-White ethnic groups (Pfast-food outlets was associated with significantly increased odds for diabetes (OR=1.02; 95% CI 1.00, 1.04) and obesity (OR=1.02; 95% CI 1.00, 1.03). This suggests that for every additional two outlets per neighbourhood, we would expect one additional diabetes case, assuming a causal relationship between the fast-food outlets and diabetes. These results suggest that increased exposure to fast-food outlets is associated with increased risk of type 2 diabetes and obesity, which has implications for diabetes prevention at a public health level and for those granting planning permission to new fast-food outlets.

  16. The effect of alcohol outlets, sales and trading hours on alcohol-related injuries presenting at emergency departments in Perth, Australia, from 2002 to 2010.

    Science.gov (United States)

    Hobday, Michelle; Chikritzhs, Tanya; Liang, Wenbin; Meuleners, Lynn

    2015-12-01

    Few studies have investigated the combined effects of alcohol sales, outlet numbers and trading hours on alcohol-related harms. This study aimed to test whether associations: (i) exist between alcohol-related emergency department (ED) injuries and alcohol sales and counts of outlets; (ii) vary between on- and off-premises outlets; and (iii) vary by trading hours conditions [extended trading permits (ETP) versus standard hours]. Panel study using 117 postcodes over 8 years (2002-10): 936 data points. Perth, Australia. ED injury presentations, aggregated to postcode-level. Alcohol-related injuries were identified using time-based surrogate measures: night injuries (n=51,241) and weekend night injuries (n=30,682). Measures of alcohol availability included number of outlets with standard and extended trading hours and mean sales per postcode. Negative binomial regression modelling with random effects was used to examine associations between availability and alcohol-related injury, controlling for socio-demographic characteristics. (i) Night injuries were associated significantly with counts of on-premises outlets [incident rate ratio (IRR)=1.046; 95% confidence interval (CI)=1.014-1.078] and sales per off-premises outlet (IRR=1.019; 95% CI=1.004-1.035); (ii) counts of on-premises outlets were positively associated with alcohol-related injury while counts of off-premises outlets indicated a negative association; and (iii) weekend night injuries increased by about 5% per on-premises outlet with an ETP (IRR=1.049; 95% CI=1.015-1.084) and by less than 1% for outlets with standard trading hours (IRR=1.008; 95% CI=1.004-1.013). Regions of Perth, Australia with greater off-premises alcohol sales and counts of on-premises alcohol outlets, particularly those with extended trading hours, appear to have higher levels of alcohol-related injuries. © 2015 Society for the Study of Addiction.

  17. Neighborhood Alcohol Outlet Density and Rates of Child Abuse and Neglect: Moderating Effects of Access to Substance Abuse Services

    Science.gov (United States)

    Morton, Cory M.; Simmel, Cassandra; Peterson, N. Andrew

    2014-01-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. PMID:24529493

  18. 7 CFR 987.56 - Outlets for utility and cull dates.

    Science.gov (United States)

    2010-01-01

    ..., utility dates and cull dates may be disposed of without inspection, but only in feed, non-table syrup... 7 Agriculture 8 2010-01-01 2010-01-01 false Outlets for utility and cull dates. 987.56 Section 987... DATES PRODUCED OR PACKED IN RIVERSIDE COUNTY, CALIFORNIA Order Regulating Handling Disposition of Other...

  19. Energy Performance of Water-based and Air-based Cooling Systems in Plus-energy Housing

    DEFF Research Database (Denmark)

    Andersen, Mads E.; Schøtt, Jacob; Kazanci, Ongun Berk

    2016-01-01

    -space, and air-to-water heat pump vs. ground heat exchanger as cooling source) on the system energy performance were investigated while achieving the same thermal indoor conditions. The results show that the water-based floor cooling system performed better than the air-based cooling system in terms of energy...... energy use reductions. The coupling of radiant floor with the ground enables to obtain “free” cooling, although the brine pump power should be kept to a minimum to fully take advantage of this solution. By implementing a ground heat exchanger instead of the heat pump and use the crawl-space air as intake...... air an improvement of 37% was achieved. The cooling demand should be minimized in the design phase as a priority and then the resulting cooling load should be addressed with the most energy efficient cooling strategy. The floor cooling coupled with a ground heat exchanger was shown to be an effective...

  20. Mass balance of Greenland's three largest outlet glaciers - 2000–2010

    NARCIS (Netherlands)

    Howat, I.M.; Ahn, Y.; Joughin, I.; van den Broeke, M.R.; Lenaerts, J.T.M.; Smith, B.

    2011-01-01

    Acceleration of Greenland's three largest outlet glaciers, Helheim, Kangerdlugssuaq and Jakobshavn Isbræ, accounted for a substantial portion of the ice sheet's mass loss over the past decade. Rapid changes in their discharge, however, make their cumulative mass-change uncertain. We derive monthly

  1. Brief report: Using global positioning system (GPS) enabled cell phones to examine adolescent travel patterns and time in proximity to alcohol outlets.

    Science.gov (United States)

    Byrnes, Hilary F; Miller, Brenda A; Morrison, Christopher N; Wiebe, Douglas J; Remer, Lillian G; Wiehe, Sarah E

    2016-07-01

    As adolescents gain freedom to explore new environments unsupervised, more time in proximity to alcohol outlets may increase risks for alcohol and marijuana use. This pilot study: 1) Describes variations in adolescents' proximity to outlets by time of day and day of the week, 2) Examines variations in outlet proximity by drinking and marijuana use status, and 3) Tests feasibility of obtaining real-time data to study adolescent proximity to outlets. U.S. adolescents (N = 18) aged 16-17 (50% female) carried GPS-enabled smartphones for one week with their locations tracked. The geographic areas where adolescents spend time, activity spaces, were created by connecting GPS points sequentially and adding spatial buffers around routes. Proximity to outlets was greater during after school and evening hours. Drinkers and marijuana users were in proximity to outlets 1½ to 2 times more than non-users. Findings provide information about where adolescents spend time and times of greatest risk, informing prevention efforts. Copyright © 2016 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  2. Experiment study on thermal mixing performance of HTR-PM reactor outlet

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Yangping, E-mail: zhouyp@mail.tsinghua.edu.cn [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); Hao, Pengfei [School of Aerospace, Tsinghua University, Beijing 100084 (China); Li, Fu; Shi, Lei [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China); He, Feng [School of Aerospace, Tsinghua University, Beijing 100084 (China); Dong, Yujie; Zhang, Zuoyi [Institute of Nuclear and New Energy Technology, Collaborative Innovation Center of Advanced Nuclear Energy Technology, the Key Laboratory of Advanced Reactor Engineering and Safety, Ministry of Education, Tsinghua University, Beijing 100084 (China)

    2016-09-15

    A model experiment is proposed to investigate the thermal mixing performance of HTR-PM reactor outlet. The design of the test facility is introduced, which is set at a scale of 1:2.5 comparing with the design of thermal mixing structure at HTR-PM reactor outlet. The test facility using air as its flow media includes inlet pipe system, electric heaters, main mixing structure, hot gas duct, exhaust pipe system and I&C system. Experiments are conducted on the test facility and the values of thermal-fluid parameters are collected and analyzed, which include the temperature, pressure and velocity of the flow as well as the temperature of the tube wall. The analysis results show the mixing efficiency of the test facility is higher than that required by the steam generator of HTR-PM, which indicates that the thermal mixing structure of HTR-PM fulfills its design requirement.

  3. Microwave-assisted low temperature fabrication of ZnO thin film electrodes for solar energy harvesting

    Energy Technology Data Exchange (ETDEWEB)

    Nirmal Peiris, T.A.; Sagu, Jagdeep S.; Hazim Yusof, Y.; Upul Wijayantha, K.G., E-mail: U.Wijayantha@lboro.ac.uk

    2015-09-01

    Metallic Zn thin films were electrodeposited on fluorine-doped tin oxide (FTO) glass substrates and oxidized under air by conventional radiant and microwave post-annealing methods to obtain ZnO thin film electrodes. The temperature of each post-annealing method was varied systematically and the photoelectrochemical (PEC) performance of electrodes was evaluated. The best photocurrent density achieved by the conventional radiant annealing method at 425 °C for 15 min was 93 μA cm{sup −2} at 1.23 V vs. NHE and the electrode showed an incident photon-to-electron conversion efficiency (IPCE) of 28.2%. X-ray diffractogram of this electrode showed that the oxidation of Zn to ZnO was not completed during the radiant annealing process as evident by the presence of metallic Zn in the electrode. For the electrode oxidized from Zn to ZnO under microwave irradiation, a photocurrent of 130 μA cm{sup −2} at 1.23 V vs. NHE and IPCE of 35.6% was observed after annealing for just 3 min, during which the temperature reached 250 °C. The photocurrent was 40% higher for the microwave annealed sample; this increase was attributed to higher surface area by preserving the nanostructure, confirmed by SEM surface topographical analysis, and better conversion yields to crystalline ZnO. Overall, it was demonstrated that oxidation of Zn to ZnO can be accomplished by microwave annealing five times faster than that of conventional annealing, thus resulting in a ~ 75% power saving. This study shows that microwave processing of materials offers significant economic and performance advantages for industrial scale up. - Highlights: • Conversion of Zn to ZnO by microwave and radiant annealing was conducted. • Microwave conversion was 5 times faster compared to radiant annealing. • Photoelectrochemical performance of microwave annealed ZnO was 40% higher. • Microwave annealing results in a 75% energy saving.

  4. Blanchability and sensory quality of large runner peanuts blanched in a radiant wall oven using infrared radiation.

    Science.gov (United States)

    Kettler, Katrina; Adhikari, Koushik; Singh, Rakesh K

    2017-10-01

    The main factors behind the growing popularity of infrared radiation heating in food processing include its energy efficiency, food quality retention and process speed, as well as the simplicity of equipment. Infrared radiation was employed as an alternative heat treatment to the conventional hot air method used in peanut blanching. The present study aimed to investigate the application of infrared heating for blanching peanuts and determine their blanchability and sensory quality under various processing conditions. The total blanchabilities (expressed as a percentage of total blanched) of the infrared radiation trials (radiant wall oven) at 343 °C for 1.5 min, 316 °C for 1.5 min, 288 °C for 1.5 min and 343 °C for 1 min did not differ significantly compared to the hot air control trials (impingement oven) at 100 °C for 30 and 20 min. All infrared trials had significantly lower (P infrared samples demonstrated the possible initiation of oxidation for the conventionally blanched sample at 18 weeks of storage at 24 °C (room temperature), with no indication of oxidation in the infrared samples stored at the same temperature. Infrared radiation peanut blanching is a viable alternative to conventional hot air blanching because of the shorter process time and longer shelf-life, as evident from the sensory storage study. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Engineering geology model of the Crater Lake outlet, Mt. Ruapehu, New Zealand, to inform rim breakout hazard

    Science.gov (United States)

    Cook, Stefan C. W.; Kennedy, Ben M.; Villeneuve, Marlène C.

    2018-01-01

    Mt. Ruapehu, in the central North Island of New Zealand, hosts a hot acidic Crater Lake over the active volcanic vent with a surface elevation of c. 2530 m.a.s.l. Volcanic activity and other montane processes have previously resulted in catastrophic releases of some or all of the c. 10 Mm3 of water retained in the lake, creating serious hazards downstream. A major lahar in March 2007 exposed a 10 m high face representative of the rock units impounding the lake, providing an opportunity to conduct both field and laboratory analysis to characterise the rock mass conditions at the outlet to assess the stability of the outlet area. This paper presents an engineering geology model of Crater Lake outlet. Our model shows three andesitic geological units at the outlet, each with different geological histories and physical and mechanical properties, which impact its stability. Geotechnical methods used to characterise the outlet include laboratory testing of the strength, stiffness, porosity and unit weight, and field-based rock mass characterisation using the geological strength index (GSI) and rock mass rating (RMR). Field observations, geomorphology mapping, historic and contemporary photographs, and laboratory results are combined to create cross sections that provide key information for establishing the engineering geology model. The units are recognised in what is informally termed the Crater Lake Formation: i) The upper surface layer is a c. 2 m thick sub-horizontal dark grey lava unit (Armoured Lava Ledge) with sub-horizontal cooling joints spaced at 0.2 m to 2.0 m intervals. The intact rock has a porosity range of 15-27%, density range of 1723-2101 kg/m3, GSI range of 45-75, and unconfined compressive strength (UCS) range of 19-48 MPa. ii) Below this, and outcropping down the majority of the outlet waterfall is a poorly sorted breccia unit composed of block and matrix material (Lava Breccia). The blocks range from 0.1 m to 0.8 m in diameter with an average porosity

  6. The influence of cooling water outlet of the Ringhals power plant on the coastal fish colony

    International Nuclear Information System (INIS)

    Neuman, E.

    1988-03-01

    Fish abundance has been monitored with fyke nets in 1976-1987 at the cooling-water outlet from the Ringhals nuclear power plant at the Swedish west coast and in a reference area. Judging from the dependence of the catches on temperature, Myoxocephalus scorpius, Zoarces viviparus, Gadus morhua and Platichtys flesus can be classified as cold-water species and Symphodus melops, Ctenolabrus rupestris, Carci nus maenas and Anguilla anguilla as warm-water species. As a rule the warm-water species were more and the cold-water fishes less abundant in the outlet area than in the reference area. The catch of the economically important Anguilla was about three times greater in the heated area. A lower abundance than expected of Ctenolabrus and Myoxocephalus at the outlet may be caused by a loss of eggs and larvae in the cooling-water system. (author)

  7. Methodological Approaches to Locating Outlets of the Franchise Retail Network

    Directory of Open Access Journals (Sweden)

    Grygorenko Tetyana M.

    2016-08-01

    Full Text Available Methodical approaches to selecting strategic areas of managing the future location of franchise retail network outlets are presented. The main stages in the assessment of strategic areas of managing the future location of franchise retail network outlets have been determined and the evaluation criteria have been suggested. Since such selection requires consideration of a variety of indicators and directions of the assessment, the author proposes a scale of evaluation, which allows generalizing and organizing the research data and calculations of the previous stages of the analysis. The most important criteria and sequence of the selection of the potential franchisees for the franchise retail network have been identified, the technique for their evaluation has been proposed. The use of the suggested methodological approaches will allow the franchiser making sound decisions on the selection of potential target markets, minimizing expenditures of time and efforts on the selection of franchisees and hence optimizing the process of development of the franchise retail network, which will contribute to the formation of its structure.

  8. A Longitudinal Analysis of Cigarette Prices in Military Retail Outlets

    Science.gov (United States)

    Haddock, Christopher Keith; Hyder, Melissa L.; Poston, Walker S. C.; Jahnke, Sara A.; Williams, Larry N.; Lando, Harry

    2014-01-01

    Objectives. We conducted a longitudinal assessment of tobacco pricing in military retail outlets, including trends within each service branch. Methods. We determined the price of a single pack of Marlboro Red cigarettes at military retail stores located in the continental United States, Alaska, and Hawaii and at their nearest Walmarts in spring 2011 and 2013 (n = 128 for pairs available at both assessments). Results. The average difference between cigarettes sold in military retail outlets and Walmarts decreased from 24.5% in 2011 to 12.5% in 2013. The decrease was partially attributable to significant price decreases at Walmarts. The largest increases in cigarette prices occurred on naval installations. Potential savings at stores on several installations remained substantial in 2013; the largest approached $6 per pack. Stores on 17 military installations decreased cigarette prices during the study period. Conclusions. Tobacco can be purchased in military retail stores at substantial savings over civilian stores. If tobacco pricing is to cease to be an incentive for use among personnel, a revised military tobacco pricing policy is needed. PMID:24524503

  9. Pemilihan food outlet sebagai faktor risiko berat badan lebih anak usia sekolah dasar di Kecamatan Tegalsari Surabaya

    Directory of Open Access Journals (Sweden)

    Renny Evelyn Hartono

    2016-08-01

    Full Text Available ABSTRACTIntroduction: Overweight and obesity are conditions resulting from an imbalance of calories in the body that occur in a long time and cause more deaths than underweight. One of factors related is food pattern, which also infl uenced the selection of food outlets. Surabaya is an urban area so it has many types and characteristic s of food outlet. Elementary school (4, 5, 6 do not really depend on their parents, so their food consumption and physical activity began to vary. Objectives: To identify the relationship between the selection of food outlets and overweight/obesity status of elementary school in Tegalsari district, Surabaya.Methods: This research used a case-control study design. Samples were 51 children for each group of cases and control and obtained from 11 primary school in the 5 subdistricts in Tegalsari district, Surabaya. Data were obtained by interview, direct observation of food outlets, and interview to select informants about the reasons of selecting food outlets . Quantitative data were processed by bivariate (chi-square and multivariate (binomial regression test. Results: Bivariate test results showed that there were signifi cant relationships between the frequency to the street vendors consumption (OR=4.09, 95% CI:1.60-10.75, frequency of fast food consumption (OR=2.86, 95% CI:1.19-6.94 and snacks (OR=6,05, 95% CI:2.20-17.62, physical activity (OR=3.09, 95% CI:1.28-7.51 and gender (OR=2.70, 95% CI:1.11-6.64 with overweight/obesity status, while frequency of stores (total, supermarket, market, mini-market, frequency of food service place (total, restaurants, fast food restaurants, frequency of vegetable and fruit consumption, and socio-economic status of respondents did not relate signifi cantly. In multivariate analysis, the variables that affected frequency of the street vendors were snack consumption, physical activity, sex and total expenditure. Conclusions: Frequency of the street vendors, fast food consumption

  10. Neighborhood alcohol outlet density and rates of child abuse and neglect: moderating effects of access to substance abuse services.

    Science.gov (United States)

    Morton, Cory M; Simmel, Cassandra; Peterson, N Andrew

    2014-05-01

    This study investigates the relationship between concentrations of on- and off-premises alcohol outlets and rates of child abuse and neglect. Additionally, the study seeks to locate protective features of a neighborhood's built environment by investigating the potentially moderating role that access to substance abuse treatment and prevention services plays in the relationship between alcohol outlet density and child maltreatment. Using a cross-sectional design, this ecological study utilized data from 163 census tracts in Bergen County, New Jersey, on reports of child abuse and neglect, alcohol outlets, substance abuse treatment and prevention facilities, and the United States Census to investigate the linkages between socioeconomic structure, alcohol availability, and access to substance abuse service facilities on rates of child abuse and neglect. Findings indicate areas with a greater concentration of on-premises alcohol outlets (i.e., bars) had higher rates of child neglect, and those with easier access to substance abuse services had lower rates of neglect, controlling for neighborhood demographic and socioeconomic structure. Additionally, the relationship between on-premises alcohol outlet density and rates of child neglect was moderated by the presence of substance abuse service facilities. A greater concentration of off-premises outlets (i.e., liquor stores) was associated with lower rates of physical abuse. Findings suggest that the built environment and socioeconomic structure of neighborhoods have important consequences for child well-being. The implications for future research on the structural features of neighborhoods that are associated with child well-being are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Development and demonstration of a gas-fired recuperative confined radiant burner (deliverable 42/43). Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-06-01

    The objective of the project was to develop and demonstrate an innovative, efficient, low-pollutant, recuperative gas-fired IR-system (infrared radiation) for industrial processes (hereafter referred to as the CONRAD-system). The CONRAD-system is confined, so flue gases from the combustion can be kept separated from the product. The gas/air mixture to the burner is preheated by means of the flue gas, which increases the radiant efficiency of the CONRAD-system significantly over traditional gas-fired IR burners. During the first phase of the project, the CONRAD-system was designed and developed. The conducted work included a survey on suitable burner materials, modelling of the burner system, basic design of burner construction, control etc., experimental characterisation of several preprototypes and detailed design of the internal heat exchanger in the burner. The result is a cost effective burner system with a documented radiant efficiency up to 66% and low emissions (NO{sub x} and CO) all in accordance with the criteria of success set up at the start of the project. In the second phase of the project, the burner system was established and tested in laboratory and in four selected industrial applications: 1) Drying of coatings on sand cores in the automotive industry. 2) Baking of bread/cake. 3) General purpose painting/powder curing process 4. Curing of powder paint on wood components. The results from the preliminary tests Overe used to optimise the CONRAD-system, before it was applied in the industrial processes and demonstrated. However, the optimised burners manufactured for demonstration suffered from different 'infant failures', which made the installation in an industrial environment very cumbersome, and even impossible in the food industry and the automotive industry. In the latter cases realistic laboratory tests Overe carried out and the established know how reported for use when the burner problems are overcome.(au)

  12. Improvement of fire-tube boilers calculation methods by the numerical modeling of combustion processes and heat transfer in the combustion chamber

    Science.gov (United States)

    Komarov, I. I.; Rostova, D. M.; Vegera, A. N.

    2017-11-01

    This paper presents the results of study on determination of degree and nature of influence of operating conditions of burner units and flare geometric parameters on the heat transfer in a combustion chamber of the fire-tube boilers. Change in values of the outlet gas temperature, the radiant and convective specific heat flow rate with appropriate modification of an expansion angle and a flare length was determined using Ansys CFX software package. Difference between values of total heat flow and bulk temperature of gases at the flue tube outlet calculated using the known methods for thermal calculation and defined during the mathematical simulation was determined. Shortcomings of used calculation methods based on the results of a study conducted were identified and areas for their improvement were outlined.

  13. Epigastric heteropagus associated with an omphalocele and double outlet right ventricle

    Directory of Open Access Journals (Sweden)

    Tatsuma Sakaguchi

    2015-10-01

    Full Text Available Incomplete or asymmetrical conjoined twins are extremely rare congenital anomalies. We report a case of epigastric heteropagus associated with an omphalocele and double outlet right ventricle. The cystic legion of the epigastrium was detected in our patient by an ultrasound scan at 28 weeks' gestation. He was born at 37 weeks' gestation by scheduled caesarean section. A parasite with an incomplete head and lower limb was attached to the epigastrium of the autosite. Surgical separation of the parasite and silo placement for an omphalocele was successfully performed on the 4th day of life. He underwent secondary surgical closure of the omphalocele on the 10th day. For treatment of the cardiac anomaly, he underwent an operation of Blalock–Taussig shunt because of pulmonary artery stenosis at the age of 3 months and correction of double outlet right ventricle at the age of 10 months. At the 20-month follow-up, he was alive and showed a normal growth pattern.

  14. Comparison of Software Models for Energy Savings from Cool Roofs

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  15. Field tests on human tolerance to (LNG) fire radiant heat exposure, and attenuation effects of clothing and other objects

    International Nuclear Information System (INIS)

    Raj, Phani K.

    2008-01-01

    A series of field tests exposing mannequins clothed with civilian clothing to a 3 m x 3 m square liquefied natural gas (LNG) pool fire was conducted. Both single layer clothing and double layer clothing were used. The radiant heat flux incident outside the clothing and incident on the skin covered by clothing were measured using wide-angle radiometers, for durations of 100-200 s (per test). The levels of heat flux incident on the clothing were close to 5 kW/m 2 . The magnitude of the radiant heat attenuation factor (AF) across the thickness was determined. AF varies between 2 and higher for cotton and polyester clothing (thickness 0.286-1.347 mm); AF value of 6 was measured for 1.347 mm thickness. Single sheet newspaper held about 5 cm in front of mannequins and exposed to incident flux of 5 kW/m 2 resulted in AF of 5, and AF of 8 with double sheets. AF decreases linearly with increasing heat flux values and linearly increases with thickness. The author exposed himself, in normal civilian clothing (of full sleeve cotton/polyester shirt and jean pants), to radiant heat from a LNG fire. The exposure was for several tens of seconds to heat flux levels ranging from 3.5 kW/m 2 to 5 + kW/m 2 (exposure times from 25 s to 97 s at average heat flux values in the 4 kW/m 2 and 5 kW/m 2 range). Occasionally, he was exposed to (as high as) 7 kW/m 2 for durations of several seconds. He did not suffer any unbearable or even severe pain nor did he experience blisters or burns or any other injury on the unprotected skin of his body. The incident heat fluxes on the author were measured by a hand-held radiometer (with digital display) as well as by strapped on wide-angle radiometers connected to a computer. He could withstand the US regulatory criterion of 5 kW/m 2 (for 30 s) without suffering any damage or burns. Temperature measured on author's skin covered by clothing did not rise above the normal body temperature even after 200 s of exposure to 4 kW/m 2 average heat flux

  16. Frequency, triggering factors and possible consequences of mass movements on outlet glaciers in Iceland.

    Science.gov (United States)

    Saemundsson, Thorsteinn; Margeirsson, Guðbjörn

    2016-04-01

    During the last 15 years several mass movements of various size and origin, e.g. rock avalanches, rock slides and debris slides have been observed to have fall on outlet glaciers in Iceland. This should not come as a surprise in this type of glacial environment, but in a way it does. When looking at the history only few mass movements are recorded to have fall on outlet glaciers in Iceland, during the decades before the year 2000 or since 1960. This "lack of mass movements" can be explained by the fact that fewer observations and monitoring were done in the past, but is it so or are we seeing increasing activity? Looking at the distribution of the known mass movements, two activity periods cam be identified. The former one around 1970 and the second one starting around 2000 and is still ongoing. Both of these periods are characterized by warmer climate leading to retreating phases of glaciers. Two larger mass movements are known from these two retreating periods. The former one occurred in January 1967. Then a large rockslide fell on the snout and into the glacial lake of the Steinholtsjökull outlet glacier in the northern side of the Eyjafjallajökull ice cap. The rockslide broke up the snout of the glacier and caused large floodwave bursting down the Steinholtsdalur valley transporting large volume of sediments down its path. The later one occurred in 2007, when a large rockavalanche fell on the Morsárjökull outlet glacier, in the southern side of the Vatnajökull ice cap. The avalanche debris covered around 1/5 of the glacier surface. Today the retreat and thinning of glaciers in Iceland are extremely rapid. The consequences of such a rapid retreat are e.g. unstable valley slopes surrounding the outlet glaciers, both in loose sediments and bedrock, thawing of mountain permafrost and not least formation of glacial lakes in front of the rapid retreating ice margins. Such conditions can become extremely hazardous, as seen by the above mentioned examples, both

  17. Characterising and comparing drug-dispensing practices at animal health outlets in the Rift Valley, Kenya: an exploratory analysis (part II).

    Science.gov (United States)

    Higham, L E; Ongeri, W; Asena, K; Thrusfield, M V

    2016-12-01

    A mixed-method study was conducted in the Rift Valley of Kenya to characterise drug-dispensing practices amongst staff at animal health outlets and to explore perceptions of veterinary medicines amongst pastoralists and farmers. Forty structured questionnaires were administered to staff at animal health outlets, including franchise outlets of 'Sidai Africa Ltd.', and two focus group discussions were facilitated to explore the perceptions of local animal health services by a Maasai pastoralist group and a dairy farmer cooperative. Differences were detected in the characteristics of Sidai outlets, agrovets, pharmacies and dukas. A greater proportion of Sidai outlet staff selected drugs based on principles of responsible drug use than staff at other types of outlet, and technical qualifications and training were associated with responsible drug use. Across all outlet types, staff knowledge and training gaps were identified, including in the correct administration of medicines. The majority of drug sales are accompanied by verbal advice to farmers. Members of the Maasai pastoralist group were concerned about accidental self-medication, withdrawal periods, drug residues and the misuse of drugs due to a lack of quality information and advice. The dairy farmer group raised similar concerns, reporting under-dosing as a common mistake amongst farmers. This study concludes that current knowledge, attitudes and practices of many service providers and livestock owners in the sale, purchase and use of veterinary medicines present risks of drug misuse and therefore the emergence of antimicrobial resistance. There is a clear demand from livestock keepers for accessible, affordable and quality animal health services and products in Kenya, and animal health practitioners have the potential to provide increased support to livestock-based livelihoods and act as stewards of our existing portfolio of animal and human medicines.

  18. Interferometric investigation of turbulently fluctuating temperature in an LMFBR outlet plenum geometry

    International Nuclear Information System (INIS)

    Bennett, R.G.; Golay, M.W.

    1975-01-01

    A novel optical technique is described for the measurement of turbulently fluctuating temperature in a transparent fluid flow. The technique employs a Mach-Zehnder interferometer of extremely short field and a simple photoconductive diode detector. The system produces a nearly linear D.C. electrical analog of the turbulent temperature fluctuations in a small, 1 mm 3 volume. The frequency response extends well above 2500 Hz, and can be improved by the choice of a more sophisticated photodetector. The turbulent sodium mixing in the ANL 1 1 / 15 -scale FFTF outlet plenum is investigated with a scale model outlet mixing plenum, using flows of air. The scale design represents a cross section of the ANL outlet plenum, so that the average recirculating flow inside the test cell is two dimensional. The range of the instrument is 120 0 F above the ambient air temperature. The accuracy is generally +-5 0 F, with most of the error due to noise originating from building vibrations and room noise. The power spectral density of the fluctuating temperature has been observed experimentally at six different stations in the flow. A strong 300 Hz component is generated in the inlet region, which decays as the flow progresses along streamlines. The effect of the inlet Reynolds number and the temperature difference between the inlet flows on the power spectral density has also been investigated. Traces of the actual fluctuating temperature are included for the six stations

  19. Neighborhood Characteristics, Alcohol Outlet Density, and Alcohol-Related Calls-for-Service: A Spatiotemporal Analysis in a Wet Drinking Country

    Directory of Open Access Journals (Sweden)

    Miriam Marco

    2017-11-01

    Full Text Available Alcohol outlets have been associated with different social problems, such as crime, violence, intimate partner violence, and child maltreatment. The spatial analysis of neighborhood availability of alcohol outlets is key for better understanding of these influences. Most studies on the spatial distribution of alcohol outlets in the community have been conducted in U.S. cities, but few studies have assessed this spatial distribution in other countries where the drinking culture may differ. The aim of this study was to analyze the spatiotemporal distribution of alcohol outlets in the city of Valencia, Spain, and its relationship with neighborhood-level characteristics, as well as to examine the influence of alcohol outlet density on alcohol-related police calls-for-service. Spain is characterized by having a “wet” drinking culture and greater social acceptance of drinking compared to the U.S. Data on alcohol outlets between 2010–2015 in three categories (off-premise, restaurants and cafes, and bars were used for the analysis. We used the 552 census block groups allocated within the city as neighborhood unit. Data were analyzed using Bayesian spatiotemporal regression models. Results showed different associations between alcohol outlets categories and neighborhood variables: off-premise density was higher in areas with lower economic status, higher immigrant concentration, and lower residential instability; restaurant and cafe density was higher in areas with higher spatially-lagged economic status, and bar density was higher in areas with higher economic status and higher spatially-lagged economic status. Furthermore, restaurant and cafe density was negatively associated with alcohol-related police calls-for-service, while bar density was positively associated with alcohol-related calls-for-service. These results can be used to inform preventive strategies for alcohol-related problems at the neighborhood-level in Spain or other countries

  20. Radiological findings of gastric adenomyoma in a neonate presenting with gastric outlet obstruction.

    Science.gov (United States)

    Rhim, Jung Hyo; Kim, Woo Sun; Choi, Young Hun; Cheon, Jung-Eun; Park, Sung Hye

    2013-03-01

    Gastric adenomyoma is a rare tumour-like lesion composed of glandular components and smooth muscle bundles. We report a case of gastric adenomyoma in a 1-week-old neonate who presented with gastric outlet obstruction. To the best of our knowledge, this is the youngest child reported with gastric adenomyoma and a unique case demonstrating radiological findings of gastric adenomyoma in a young infant. At US, the lesion was seen as an asymmetrical mass-like wall-thickening of the pylorus. Upper gastrointestinal series showed findings similar to those seen in a case of hypertrophic pyloric stenosis. We suggest that gastric adenomyoma should be included in the causes of gastric outlet obstruction in neonates even though it is rare in young children.

  1. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  2. Radiant thinking and the use of the mind map in nurse practitioner education.

    Science.gov (United States)

    Spencer, Julie R; Anderson, Kelley M; Ellis, Kathryn K

    2013-05-01

    The concept of radiant thinking, which led to the concept of mind mapping, promotes all aspects of the brain working in synergy, with thought beginning from a central point. The mind map, which is a graphical technique to improve creative thinking and knowledge attainment, utilizes colors, images, codes, and dimensions to amplify and enhance key ideas. This technique augments the visualization of relationships and links between concepts, which aids in information acquisition, data retention, and overall comprehension. Faculty can promote students' use of the technique for brainstorming, organizing ideas, taking notes, learning collaboratively, presenting, and studying. These applications can be used in problem-based learning, developing plans of care, health promotion activities, synthesizing disease processes, and forming differential diagnoses. Mind mapping is a creative way for students to engage in a unique method of learning that can expand memory recall and help create a new environment for processing information. Copyright 2013, SLACK Incorporated.

  3. A porcine model of bladder outlet obstruction incorporating radio-telemetered cystometry.

    Science.gov (United States)

    Shaw, Matthew B; Herndon, Claude D; Cain, Mark P; Rink, Richard C; Kaefer, Martin

    2007-07-01

    To present a novel porcine model of bladder outlet obstruction (BOO) with a standardized bladder outlet resistance and real-time ambulatory radio-telemetered cystometry, as BOO is a common condition with many causes in both adults and children, with significant morbidity and occasional mortality, but attempts to model this condition in many animal models have the fundamental problem of standardising the degree of outlet resistance. BOO was created in nine castrated male pigs by dividing the mid-urethra; outflow was allowed through an implanted bladder drainage catheter containing a resistance valve, allowing urine to flow across the valve only when a set pressure differential was generated across the valve. An implantable radio-telemetered pressure sensor monitored the pressure within the bladder and abdominal cavity, and relayed this information to a remote computer. Four control pigs had an occluded bladder drainage catheter and pressure sensor placed, but were allowed to void normally through the native urethra. Intra-vesical pressure was monitored by telemetry, while the resistance valve was increased weekly, beginning with 2 cmH2O and ultimately reaching 10 cmH2O. The pigs were assessed using conventional cystometry under anaesthesia before death, and samples conserved in formalin for haematoxylin and eosin staining. The pigs had radio-telemetered cystometry for a median of 26 days. All telemetry implants functioned well for the duration of the experiment, but one pig developed a urethral fistula and was excluded from the study. With BOO the bladder mass index (bladder mass/body mass x 10 000) increased from 9.7 to 20 (P = 0.004), with a significant degree of hypertrophy of the detrusor smooth muscle bundles. Obstructed bladders were significantly less compliant than control bladders (8.3 vs 22.1 mL/cmH2O, P = 0.03). Telemetric cystometry showed that there was no statistically significance difference in mean bladder pressure between obstructed and control pigs

  4. Geographic Accessibility Of Food Outlets Not Associated With Body Mass Index Change Among Veterans, 2009-14.

    Science.gov (United States)

    Zenk, Shannon N; Tarlov, Elizabeth; Wing, Coady; Matthews, Stephen A; Jones, Kelly; Tong, Hao; Powell, Lisa M

    2017-08-01

    In recent years, various levels of government in the United States have adopted or discussed subsidies, tax breaks, zoning laws, and other public policies that promote geographic access to healthy food. However, there is little evidence from large-scale longitudinal or quasi-experimental research to suggest that the local mix of food outlets actually affects body mass index (BMI). We used a longitudinal design to examine whether the proximity of food outlets, by type, was associated with BMI changes between 2009 and 2014 among 1.7 million veterans in 382 metropolitan areas. We found no evidence that either absolute or relative geographic accessibility of supermarkets, fast-food restaurants, or mass merchandisers was associated with changes in an individual's BMI over time. While policies that alter only geographic access to food outlets may promote equitable access to healthy food and improve nutrition, our findings suggest they will do little to combat obesity in adults. Project HOPE—The People-to-People Health Foundation, Inc.

  5. Associations between childhood obesity and the availability of food outlets in the local environment: a retrospective cross-sectional study.

    Science.gov (United States)

    Miller, Laura J; Joyce, Sarah; Carter, Shannon; Yun, Grace

    2014-01-01

    Examine whether individual-level childhood obesity is related to residential availability of fast food and healthy food outlets. Retrospective cross-sectional study. Perth, Western Australia. A total of 1850 children aged 5 to 15 years in 2005-2010 who participated in the Western Australian Health and Wellbeing Surveillance System survey. Geographical Information Systems were used to calculate a range of measures of fast food and healthy food outlet access and availability. For example, distance to nearest and access and density measures within 800 m and 3 km of each child's residence were all tested. Multivariate logistic regression analysis, controlling for individual-level sociodemographic factors and lifestyle behaviors. An increasing number of healthy food outlets within 800 m of a child's home was associated with a significantly reduced risk of being overweight/obese in all models tested. After controlling for age, physical activity, time spent sedentary, weekly takeaway consumption, area disadvantage, and count of fast food outlets, each additional healthy food outlet within 800 m was associated with a 20% decrease in the likelihood of a child being overweight or obese (odds ratio: .800, 95% confidence intervals: .686-.933). The local food environment around children's homes has an independent effect on child weight status. These findings highlight the importance of the built environment as a potential contributor towards child health, which should be considered when developing community health promotion programs.

  6. Rapid Holocene thinning of outlet glaciers followed by readvance in the western Ross Embayment, Antarctica

    Science.gov (United States)

    Jones, R. S.; Whitmore, R.; Mackintosh, A.; Norton, K. P.; Eaves, S.; Stutz, J.

    2017-12-01

    Investigating Antarctic deglaciation following the LGM provides an opportunity to better understand patterns, mechanisms and drivers of ice sheet retreat. In the Ross Sea sector, geomorphic features preserved on the seafloor indicate that streaming East Antarctic outlet glaciers once extended >100 km offshore of South Victoria Land prior to back-stepping towards their modern configurations. In order to adequately interpret the style and causes of this retreat, the timing and magnitude of corresponding ice thickness change is required. We present new constraints on ice surface lowering from Mawson Glacier, an outlet of the East Antarctic Ice Sheet that flows into the western Ross Sea. Surface-exposure (10Be) ages from samples collected in elevation transects above the modern ice surface reveal that rapid thinning occurred at 5-8 ka, broadly coeval with new ages of grounding-line retreat at 6 ka and rapid thinning recorded at nearby Mackay Glacier at 7 ka. Our data also show that a moraine formed near to the modern ice margin of Mawson Glacier at 0.8 ka, which, together with historical observations, indicates that glaciers in this region readvanced during the last thousand years. We argue that 1) the accelerated thinning of outlet glaciers was driven by local grounding-line retreat through overdeepened basins during the early-mid Holocene, and 2) the glaciers subsequently readvanced, possibly linked to late Holocene sea-ice expansion, before retreating to their current positions. Our work demonstrates that these outlet glaciers were closely coupled to environmental and topography-induced perturbations near their termini throughout the Holocene.

  7. Climatology, hydrology, and simulation of an emergency outlet, Devils Lake basin, North Dakota

    Science.gov (United States)

    Wiche, Gregg J.; Vecchia, A.V.; Osborne, Leon; Wood, Carrie M.; Fay, James T.

    2000-01-01

    Devils Lake is a natural lake in northeastern North Dakota that is the terminus of a nearly 4,000-square-mile subbasin in the Red River of the North Basin. The lake has not reached its natural spill elevation to the Sheyenne River (a tributary of the Red River of the North) in recorded history. However, geologic evidence indicates a spill occurred sometime within the last 1,800 years. From 1993 to 1999, Devils Lake rose 24.5 feet and, at the present (August 2000), is about 13 feet below the natural spill elevation. The recent lake-level rise has caused flood damages exceeding $300 million and triggered development of future flood-control options to prevent further infrastructure damage and reduce the risk of a potentially catastrophic uncontrolled spill. Construction of an emergency outlet from the west end of Devils Lake to the Sheyenne River is one flood-control option being considered. This report describes the climatologic and hydrologic causes of the recent lake level rise, provides information on the potential for continued lake-level rises during the next 15 years, and describes the potential effectiveness of an emergency outlet in reducing future lake levels and in reducing the risk of an uncontrolled spill. The potential effects of an outlet on downstream water quantity and quality in the upper Sheyenne River also are described.

  8. Arrhenius activation energy of damage to catalase during spray-drying.

    Science.gov (United States)

    Schaefer, Joachim; Lee, Geoffrey

    2015-07-15

    The inactivation of catalase during spray-drying over a range of outlet gas temperatures could be closely represented by the Arrhenius equation. From this an activation energy for damage to the catalase could be calculated. The close fit to Arrhenius suggests that the thermally-induced part of inactivation of the catalase during the complex drying and particle-formation processes takes place at constant temperature. These processes are rapid compared with the residence time of the powder in the collecting vessel of the cyclone where dried catalase is exposed to a constant temperature equal to approximately the drying gas outlet temperature. A lower activation energy after spray drying with the ultrasonic nozzle was found than with the 2-fluid nozzle under otherwise identical spray drying conditions. It is feasible that the ultrasonic nozzle when mounted in the lid of the spray dryer heats up toward the drying gas inlet temperature much more that the air-cooled 2-fluid nozzle. Calculation of the Arrhenius activation energy also showed how the stabilizing efficacy of trehalose and mannitol on the catalase varies in strength across the range of drying gas inlet and outlet temperatures examined. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Sodium steam generator within which are inlet and outlet ducts with pipe bundles in vessel

    International Nuclear Information System (INIS)

    1980-01-01

    The sodium steam generator with internal flow ducts for inlet and outlet to a vessel are provided as pipe bundles in the form of helically wound concentric layers terminating in inlet and outlet connections with chambers, characterised in that within the vessel, the pipe pieces which are connected to the pipe windings with the said vessel are arranged in substantially radially aligned rows so that each row measured in the circumferential direction at least on one side is at a spacing from the following row sufficiently large that between the rows or groups of rows an open sector is provided. (G.C.)

  10. Alcohol outlets near schools in a midsize Romanian city. Prevalence and chararteristics

    NARCIS (Netherlands)

    van Hoof, Joris Jasper; Reijlink, Lian M.J.; van Dalen, Wim E.

    2010-01-01

    Objective: alcohol availability is one of the strongest predictors of adolescent alcohol use, and subsequent harm. Alcohol outlets near schools are an important indicator of three types of availability related to adolescent alcohol use; physical (number), economic (price), and legal (compliance with

  11. Requirements under decree 430 UJD for unit outlet and standby power supply

    International Nuclear Information System (INIS)

    Vanco, K.

    2012-01-01

    At present, the nuclear power plants are only sufficient resources, which can cover a huge demand for electricity. Concentration so huge power in one place require adequate security from the perspective lead power outlet and standby power supply of reactor unit. (Author)

  12. Positioning invasive versus noninvasive urodynamics in the assessment of bladder outlet obstruction

    NARCIS (Netherlands)

    Arnolds, Michiel; Oelke, Matthias

    2009-01-01

    Purpose of review To provide evidence of promising tests to noninvasively diagnose bladder outlet obstruction (800) in men with benign prostatic hyperplasia. Recent findings Pressure-flow studies are usually performed to prove BOO prior to prostatectomy. However, pressure-flow studies are invasive,

  13. Outlet Glacier-Ice Shelf-Ocean Interactions: Is the Tail Wagging the Dog?

    Science.gov (United States)

    Parizek, B. R.; Walker, R. T.; Rinehart, S. K.

    2009-12-01

    While the massive interior regions of the Antarctic and Greenland Ice Sheets are presently ``resting quietly", the lower elevations of many outlet glaciers are experiencing dramatic adjustments due to changes in ice dynamics and/or surface mass balance. Oceanic and/or atmospheric forcing in these marginal regions often leads to mass deficits for entire outlet basins. Therefore, coupling the wagging tail of ice-ocean interactions with the vast ice-sheet reservoirs is imperative for accurate assessments of future sea-level rise. To study ice-ocean dynamic processes, we couple an ocean-plume model that simulates ice-shelf basal melting rates based on temperature and salinity profiles combined with plume dynamics associated with the geometry of the ice-shelf cavity (following Jenkins, 1991 and Holland and Jenkins, 1999) with a two-dimensional, isothermal model of outlet glacier-ice shelf flow (as used in Alley et al., 2007; Walker et al., 2008; Parizek et al., in review). Depending on the assigned temperature and salinity profiles, the ocean model can simulate both water-mass end-members: either cold High Salinity Shelf Water (HSSW) or relatively warm Circumpolar Deep Water (CDW), as well as between-member conditions. Notably, the coupled system exhibits sensitivity to the initial conditions. In particular, melting concentrated near the grounding line has the greatest effect in forcing grounding-line retreat. Retreat is further enhanced by a positive feedback between the ocean and ice, as the focused melt near the grounding line leads to an increase in the local slope of the basal ice, thereby enhancing buoyancy-driven plume flow and subsequent melt rates.

  14. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  15. Supraclavicular scalenectomy for thoracic outlet syndrome--functional outcomes assessed using the DASH scoring system.

    LENUS (Irish Health Repository)

    Glynn, Ronan W

    2012-02-01

    To evaluate supraclavicular scalenectomy ± cervical rib excision for thoracic outlet syndrome (TOS), employing Disability of Arm, Shoulder, and Hand (DASH) scoring for functional assessment post-decompression.

  16. Electrical Power Quality - What's Behind the Outlet?

    Science.gov (United States)

    Baird, William H.; Secrest, Jeffery; Padgett, Clifford

    2017-09-01

    Although we may consider the power outlets in our homes to be nearly ideal voltage sources, a variety of influences in and around the home can cause departures from the nominal 60 Hz, 110-120 V root-mean-square (rms) of the North American grid. Even without instrumentation, we can see that a large motor starting from rest can be sufficient to cause lights to dim momentarily (voltage sag). This dimming is due to the inrush current drawn by a stationary motor, which may be several times the current drawn at operating speed. We prepared a voltage monitoring system using a voltage divider, the construction details of which we omit in the interest of safety.

  17. Biomass bale stack and field outlet locations assessment for efficient infield logistics

    Science.gov (United States)

    Harvested hay or biomass are traditionally baled for better handling and they are transported to the outlet for final utilization. For better management of bale logistics, producers often aggregate bales into stacks so that bale-hauling equipment can haul multiple bales for improved efficiency. Obje...

  18. Everolimus for Advanced Pancreatic Neuroendocrine Tumours: A Subgroup Analysis Evaluating Japanese Patients in the RADIANT-3 Trial

    Science.gov (United States)

    Ito, Tetsuhide; Okusaka, Takuji; Ikeda, Masafumi; Igarashi, Hisato; Morizane, Chigusa; Nakachi, Kohei; Tajima, Takeshi; Kasuga, Akio; Fujita, Yoshie; Furuse, Junji

    2012-01-01

    Objective Everolimus, an inhibitor of the mammalian target of rapamycin, has recently demonstrated efficacy and safety in a Phase III, double-blind, randomized trial (RADIANT-3) in 410 patients with low- or intermediate-grade advanced pancreatic neuroendocrine tumours. Everolimus 10 mg/day provided a 2.4-fold improvement compared with placebo in progression-free survival, representing a 65% risk reduction for progression. The purpose of this analysis was to investigate the efficacy and safety of everolimus in the Japanese subgroup enrolled in the RADIANT-3 study. Methods Subgroup analysis of the Japanese patients was performed comparing efficacy and safety between everolimus 10 mg/day orally (n = 23) and matching placebo (n = 17). The primary endpoint was progression-free survival. Safety was evaluated on the basis of the incidence of adverse drug reactions. Results Progression-free survival was significantly prolonged with everolimus compared with placebo. The median progression-free survival was 19.45 months (95% confidence interval, 8.31–not available) with everolimus vs 2.83 months (95% confidence interval, 2.46–8.34) with placebo, resulting in an 81% risk reduction in progression (hazard ratio, 0.19; 95% confidence interval, 0.08–0.48; P< 0.001). Adverse drug reactions occurred in all 23 (100%) Japanese patients receiving everolimus and in 13 (77%) patients receiving placebo; most were grade 1/2 in severity. The most common adverse drug reactions in the everolimus group were rash (n = 20; 87%), stomatitis (n = 17; 74%), infections (n = 15; 65%), nail disorders (n = 12; 52%), epistaxis (n = 10; 44%) and pneumonitis (n = 10; 44%). Conclusions These results support the use of everolimus as a valuable treatment option for Japanese patients with advanced pancreatic neuroendocrine tumours. PMID:22859827

  19. Prolapsing Gastric Polyp Causing Intermittent Gastric Outlet Obstruction.

    Science.gov (United States)

    Kosai, Nik Ritza; Gendeh, Hardip Singh; Norfaezan, Abdul Rashid; Razman, Jamin; Sutton, Paul Anthony; Das, Srijit

    2015-06-01

    Gastric polyps are often an incidental finding on upper gastrointestinal endoscopy, with an incidence up to 5%. The majority of gastric polyps are asymptomatic, occurring secondary to inflammation. Prior reviews discussed Helicobacter pylori (H pylori)-associated singular gastric polyposis; however, we present a rare and unusual case of recurrent multiple benign gastric polyposis post H pylori eradication resulting in intermittent gastric outlet obstruction. A 70-year-old independent male, Chinese in ethnicity, with a background of diabetes mellitus, hypertension, and a simple renal cyst presented with a combination of melena, anemia, and intermittent vomiting of partially digested food after meals. Initial gastroscopy was positive for H pylori; thus he was treated with H pylori eradication and proton pump inhibitors. Serial gastroscopy demonstrated multiple sessile gastric antral polyps, the largest measuring 4 cm. Histopathologic examination confirmed a benign hyperplastic lesion. Computed tomography identified a pyloric mass with absent surrounding infiltration or metastasis. A distal gastrectomy was performed, whereby multiple small pyloric polyps were found, the largest prolapsing into the pyloric opening, thus explaining the intermittent nature of gastric outlet obstruction. Such polyps often develop from gastric ulcers and, if left untreated, may undergo neoplasia to form malignant cells. A distal gastrectomy was an effective choice of treatment, taking into account the polyp size, quantity, and potential for malignancy as opposed to an endoscopic approach, which may not guarantee a complete removal of safer margins and depth. Therefore, surgical excision is favorable for multiple large gastric polyps with risk of malignancy.

  20. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    Science.gov (United States)

    Abu Anas, Emran Mohammad; Kim, Jae Gon; Lee, Soo Yeol; Kamrul Hasan, Md

    2011-10-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  1. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging

    International Nuclear Information System (INIS)

    Anas, Emran Mohammad Abu; Hasan, Md Kamrul; Kim, Jae Gon; Lee, Soo Yeol

    2011-01-01

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  2. Measurement of unsteady airflow velocity at nozzle outlet

    Science.gov (United States)

    Pyszko, René; Machů, Mário

    2017-09-01

    The paper deals with a method of measuring and evaluating the cooling air flow velocity at the outlet of the flat nozzle for cooling a rolled steel product. The selected properties of the Prandtl and Pitot sensing tubes were measured and compared. A Pitot tube was used for operational measurements of unsteady dynamic pressure of the air flowing from nozzles to abtain the flow velocity. The article also discusses the effects of air temperature, pressure and relative air humidity on air density, as well as the influence of dynamic pressure filtering on the error of averaged velocity.

  3. Potency of Solar Energy Applications in Indonesia

    Directory of Open Access Journals (Sweden)

    Noer Abyor Handayani

    2012-07-01

    Full Text Available Currently, 80% of conventional energy is used to fulfill general public's needs andindustries. The depletion of oil and gas reserves and rapid growth in conventional energyconsumption have continuously forced us to discover renewable energy sources, like solar, wind,biomass, and hydropower, to support economic development in the future. Solar energy travels at aspeed of 186,000 miles per second. Only a small part of the radiant energy that the sun emits intospace ever reaches the Earth, but that is more than enough to supply all our energy demand.Indonesia is a tropical country and located in the equator line, so it has an abundant potential ofsolar energy. Most of Indonesian area get enough intensity of solar radiation with the average dailyradiation around 4 kWh/m2. Basically, the solar systems use solar collectors and concentrators forcollecting, storing, and using solar radiation to be applied for the benefit of domestics, commercials,and industrials. Common applications for solar thermal energy used in industry are the SWHs, solardryers, space heating, cooling systems and water desalination.

  4. Numerical Research about Influence of Blade Outlet Angle on Flow-Induced Noise and Vibration for Centrifugal Pump

    Directory of Open Access Journals (Sweden)

    Ailing Yang

    2014-03-01

    Full Text Available A hybrid numerical method was used to calculate the flow-induced noise and vibration of the centrifugal pump in the paper. The unsteady flows inside the centrifugal pumps with different blade outlet angles were simulated firstly. The unsteady pressure on the inner surface of the volute and the unsteady force applied on the impeller were analyzed. Then the vibration of the volute and sound field were calculated based on an acoustic-vibro-coupling method. The results show that the pump head has increased 7% while the hydraulic efficiency decreased 11.75% as blade outlet angles increased from 18° to 39°. The amplitude of pressure fluctuation at the first blade passing frequency has decreased but increased at the second-order blade passing frequency as the angle growing. The total fluctuation power near volute tongue goes up about 12% every 3° increment of blade outlet angle. The results also show that vibrating-velocity of the volute at second-order blade passing frequency is much higher than at other frequencies, and the velocity increases rapidly as blade outlet angle varies from 18° to 39°. At the same time, the sound pressure level outside the pump has increased about 8.6 dB when the angle increased from 18° to 39°.

  5. Application of the PROMETHEE technique to determine depression outlet location and flow direction in DEM

    Science.gov (United States)

    Chou, Tien-Yin; Lin, Wen-Tzu; Lin, Chao-Yuan; Chou, Wen-Chieh; Huang, Pi-Hui

    2004-02-01

    With the fast growing progress of computer technologies, spatial information on watersheds such as flow direction, watershed boundaries and the drainage network can be automatically calculated or extracted from a digital elevation model (DEM). The stubborn problem that depressions exist in DEMs has been frequently encountered while extracting the spatial information of terrain. Several filling-up methods have been proposed for solving depressions. However, their suitability for large-scale flat areas is inadequate. This study proposes a depression watershed method coupled with the Preference Ranking Organization METHod for Enrichment Evaluations (PROMETHEEs) theory to determine the optimal outlet and calculate the flow direction in depressions. Three processing procedures are used to derive the depressionless flow direction: (1) calculating the incipient flow direction; (2) establishing the depression watershed by tracing the upstream drainage area and determining the depression outlet using PROMETHEE theory; (3) calculating the depressionless flow direction. The developed method was used to delineate the Shihmen Reservoir watershed located in Northern Taiwan. The results show that the depression watershed method can effectively solve the shortcomings such as depression outlet differentiating and looped flow direction between depressions. The suitability of the proposed approach was verified.

  6. Infantile myofibromatosis: a most unusual cause of gastric outlet obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Rohrer, Kellie; Murphy, Robyn; Thresher, Caroline; Jacir, Nabil; Bergman, Kerry [Morristown Memorial Hospital, Department of Radiology, Morristown, NJ (United States)

    2005-08-01

    Non-bilious vomiting in the newborn is common. Etiologies include both surgical and medical conditions. Gastroesophageal reflux, soy or milk protein allergy, and prostaglandin-induced foveolar hyperplasia are among the medical causes. Surgical entities include gastric antral webs, pre-ampullary duodenal and pyloric atresia, and hypertrophic pyloric stenosis. We report the unique case of an 8-day-old girl who presented with gastric outlet obstruction secondary to infantile myofibromatosis. (orig.)

  7. Pemilihan food outlet sebagai faktor risiko berat badan lebih anak usia sekolah dasar di Kecamatan Tegalsari Surabaya

    OpenAIRE

    Renny Evelyn Hartono; BJ. Istiti Kandarina; Siti Helmyati

    2016-01-01

    ABSTRACTIntroduction: Overweight and obesity are conditions resulting from an imbalance of calories in the body that occur in a long time and cause more deaths than underweight. One of factors related is food pattern, which also infl uenced the selection of food outlets. Surabaya is an urban area so it has many types and characteristic s of food outlet. Elementary school (4, 5, 6) do not really depend on their parents, so their food consumption and physical activity began to vary. Objectives:...

  8. Area deprivation and the food environment over time: A repeated cross-sectional study on takeaway outlet density and supermarket presence in Norfolk, UK, 1990-2008.

    Science.gov (United States)

    Maguire, Eva R; Burgoine, Thomas; Monsivais, Pablo

    2015-05-01

    Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. A study on the performance valuation of small size water storage electric boiler

    International Nuclear Information System (INIS)

    Mo, Joung Gun; Shin, Jae Ho; Bae, Chul Whan; Suh, Jeong Se; Chung, Han Shik; Jeong, Hyo Min

    2003-01-01

    We was made 150L a water storage electric boiler and obtained various performances of the storage, radiant and keeping by experimentation. The storage performance is that the heat were off about 50 minutes after heating start. Then the temperature of outlet was arrived the stead state at 91 deg. C and the storage performance was appeared 93.64%. In the radiant performance, the water temperature was decreased from 90 .deg. C to 44.8 deg. C after 960 minutes. Then the calorific value changed from 675kcal/h to 72kcal/h and the temperature decreased about 50%. The keeping performance showed mean temperature, 67.06 .deg. C according to progress 800 minutes and the maximum temperature drop were 0.2 .deg. C. By the results of the performance valuation, the water storage electric boiler was verified fitted quality on the test prescription of KERI (Korea Electrotechnology Research Institute.)

  10. The ICS-'BPH' Study: uroflowmetry, lower urinary tract symptoms and bladder outlet obstruction

    NARCIS (Netherlands)

    Reynard, J. M.; Yang, Q.; Donovan, J. L.; Peters, T. J.; Schafer, W.; de la Rosette, J. J.; Dabhoiwala, N. F.; Osawa, D.; Lim, A. T.; Abrams, P.

    1998-01-01

    To explore the relationship between uroflow variables and lower urinary tract symptoms (LUTS): to define performance statistics (sensitivity, specificity, positive and negative predictive values) for maximum urinary flow rate (Qmax) with respect to bladder outlet obstruction (BOO) at various

  11. Antral hyperplastic polyp causing intermittent gastric outlet obstruction: Case report

    Directory of Open Access Journals (Sweden)

    Kurtkaya-Yapicier Ozlem

    2003-06-01

    Full Text Available Abstract Background Hyperplastic polyps are the most common polypoid lesions of the stomach. Rarely, they cause gastric outlet obstruction by prolapsing through the pyloric channel, when they arise in the prepyloric antrum. Case presentation A 62-year-old woman presented with intermittent nausea and vomiting of 4 months duration. Upper gastrointestinal endoscopy revealed a 30 mm prepyloric sessile polyp causing intermittent gastric outlet obstruction. Following submucosal injection of diluted adrenaline solution, the polyp was removed with a snare. Multiple biopsies were taken from the greater curvature of the antrum and the corpus. Rapid urease test for Helicobacter pylori yielded a negative result. Histopathologic examination showed a hyperplastic polyp without any evidence of malignancy. Biopsies of the antrum and the corpus revealed gastritis with neither atrophic changes nor Helicobacter pylori infection. Follow-up endoscopy after a 12-week course of proton pomp inhibitor therapy showed a complete healing without any remnant tissue at the polypectomy site. The patient has been symptom-free during 8 months of follow-up. Conclusions Symptomatic gastric polyps should be removed preferentially when they are detected at the initial diagnostic endoscopy. Polypectomy not only provides tissue to determine the exact histopathologic type of the polyp, but also achieves radical treatment.

  12. Complot test section outlet CFD optimization (pre - test and dimensioning)

    International Nuclear Information System (INIS)

    Profir, M. M.; Moreau, V.; Kennedy, G.

    2013-01-01

    In the framework of the FP7 MAXSIMA European project, the COMPLOT (COMPonent LOop Testing) LBE experimental facility is employed for thermal-hydraulic experiments aimed to test and qualify, among other components, a buoyancy driven safety/control rods (SR/CR) system, as key components for the safe operation of the MYRRHA reactor. This paper focuses mainly on a simplified CFD representation of the SR test section outlet in order to optimise it for the testing program. Parametric cases, associated with different positions of the SR assembly have been set up and analysed. A quasi-static analysis has been performed for each case, accounting for the LBE volume displaced by the insertion of the SR bundle, by introducing appropriately positioned additional mass sources. Velocity and pressure fields, as well as pressure drop magnitudes and mass flow rates through relevant guide tube hole outlets have been calculated and compared. The CFD analysis proved that the outer boundary of the test section does not impact the expected performance of the SR (rapid transient downward insertion). Preliminary simulations reproducing the timely repositioning of the SR/CR in COMPLOT using procedures of automatic volume mesh regeneration, consistently with the rod imposed displacement, are illustrated. (authors)

  13. Applications of plasma core reactors to terrestrial energy systems

    International Nuclear Information System (INIS)

    Lantham, T.S.; Biancardi, F.R.; Rodgers, R.J.

    1974-01-01

    Plasma core reactors offer several new options for future energy needs in addition to space power and propulsion applications. Power extraction from plasma core reactors with gaseous nuclear fuel allows operation at temperatures higher than conventional reactors. Highly efficient thermodynamic cycles and applications employing direct coupling of radiant energy are possible. Conceptual configurations of plasma core reactors for terrestrail applications are described. Closed-cycle gas turbines, MHD systems, photo- and thermo-chemical hydrogen production processes, and laser systems using plasma core reactors as prime energy sources are considered. Cycle efficiencies in the range of 50 to 65 percent are calculated for closed-cycle gas turbine and MHD electrical generators. Reactor advantages include continuous fuel reprocessing which limits inventory of radioactive by-products and thorium-U-233 breeder configurations with about 5-year doubling times

  14. Temperature measurements at the LMFBR core outlet

    International Nuclear Information System (INIS)

    Argous, J.P.; Berger, R.; Casejuane, R.; Fournier, C.; Girard, J.P.

    1980-04-01

    Over the last few years the temperature sensors used to measure the subassembly outlet temperature in French designed LMFBRs have been modified, basically in an effort to reduce the dispersion of the chromel-alumel thermocouple time constant, and to extend the frequency spectrum of the measurement signals by adding a steel electrode to from a stainless steel-sodium thermocouple. The result of this evolution is the temperature probe immersed in sodium which will be used in the SUPER PHENIX reactor. This paper describes the tests already completed or in progress on this probe. It also presents measurement data on the two basic probe parameters: the thermoelectric power of the stainless steel-sodium thermocouple and the time constant of the chromel-alumel thermocouple

  15. Tidal energy conversion. Renewable energy; 3-3 choseki / choryu hatsuden. II. saisei kano energy ni yoru hatsuden

    Energy Technology Data Exchange (ETDEWEB)

    Makino, T. [Tobishima Corp., Tokyo (Japan)

    1998-10-15

    There are not much examples applying tidal energy conversion, but tide and tidal current phenomena can be forecasted so correctly regardless of weather that the applying tidal energy is to be expected in the future. The largest tidal power plant is at Reims in France and install 24 Kaplan turbines each of which outlet power is 10,000kW (rotational direction is reversible) on the breakwater (750m is length). Tidal range at this place being 8.5m on an average, during the period of flowing seawater into the reservoir and on the contrary during the period of discharging seawater to the sea generation is both performed. Though there is no actual result of tidal power plant in Japan, in tidal current power system experimental generators have been installed at Kurushima channel and Naruto channel. Nihon University carried out various kinds of experiment using a Darius turbine (1.6m in dia.) at Kurushima channel and got outlet power of 3kW at the maximum (1983-`88). There are few coasts which have sufficient tide range in Japan, but there are so good many applicable coasts in China and Southeast Asia that the tidal power generation is to be expectatively. 12 refs., 5 figs., 1 tab.

  16. Area deprivation and the food environment over time: A repeated cross-sectional study on takeaway outlet density and supermarket presence in Norfolk, UK, 1990–2008

    Science.gov (United States)

    Maguire, Eva R.; Burgoine, Thomas; Monsivais, Pablo

    2015-01-01

    Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. PMID:25841285

  17. Thermal Texture Selection and Correction for Building Facade Inspection Based on Thermal Radiant Characteristics

    Science.gov (United States)

    Lin, D.; Jarzabek-Rychard, M.; Schneider, D.; Maas, H.-G.

    2018-05-01

    An automatic building façade thermal texture mapping approach, using uncooled thermal camera data, is proposed in this paper. First, a shutter-less radiometric thermal camera calibration method is implemented to remove the large offset deviations caused by changing ambient environment. Then, a 3D façade model is generated from a RGB image sequence using structure-from-motion (SfM) techniques. Subsequently, for each triangle in the 3D model, the optimal texture is selected by taking into consideration local image scale, object incident angle, image viewing angle as well as occlusions. Afterwards, the selected textures can be further corrected using thermal radiant characteristics. Finally, the Gauss filter outperforms the voted texture strategy at the seams smoothing and thus for instance helping to reduce the false alarm rate in façade thermal leakages detection. Our approach is evaluated on a building row façade located at Dresden, Germany.

  18. Influence on living body by radiant rays produced in low power reactor

    International Nuclear Information System (INIS)

    Ogura, Isao; Nakamura, Katsuichi; Usuyama, Hideo; Usui, Akinori; Hosomi, Takashi; Yoshimura, Yoshinao; Nakai, Takahide; Egashira, Masamichi

    1984-01-01

    There is possibility of a risk that a living body is irradiated by those for slightly indifference to radiant rays, radiation source or devices of low level dose or dose rate. Accordingly, a low power reactor (UTR-KINKI) was utilized for a observation of influence by radiation of low level dose or dose rate, the rabbits were irradiated in it at output 1 w. The large influence was not expected for the low level dose rate of 1.313 Rad/hr even if they were irradiated for the several hours, but in a part of blood components a slight change was recognized. The change of M pattern in white blood corpuscle number was indicated likewise as irradiation of 500R X-ray, reported from Jacobson and others, by irradiation to about 13 Rads. In addition, lymphocyte number was increased considerably in an early stage. This fact will be useful for a recovery of an injury as mentioned by Lucky. The rabbits of alloxan diabetes mellitus and hepatitis were irradiated in the same way as above, but they scarcely showed the alterations. However, numerous rabbits can't be used in this experiment for the equipment and others. (author)

  19. Computer supervision of the core outlet sodium temperatures of FBTR

    International Nuclear Information System (INIS)

    Boopathy, C.

    1976-01-01

    Safety monitoring of the fast breeder test reactor at Kalpakkam (India) is achieved by a CDPS-on-line dual computer system which is dedicated to plant supervision. The on-line subsystem scans and supervises all the 170 core thermocouple signals every second. Organisation of the reactor core instruments, supervision of mean sodium outlet temperature and mean temperature drop across the core, detection of plugging of a fuel assembly are explained. (A.K.)

  20. Tobacco retail outlet advertising practices and proximity to schools, parks and public housing affect Synar underage sales violations in Washington, DC.

    Science.gov (United States)

    Kirchner, Thomas R; Villanti, Andrea C; Cantrell, Jennifer; Anesetti-Rothermel, Andrew; Ganz, Ollie; Conway, Kevin P; Vallone, Donna M; Abrams, David B

    2015-03-01

    To examine the cross-sectional association between illicit sales of tobacco to minors, Washington DC tobacco outlet advertising practices, retail store type, the demographic make-up of the area surrounding each outlet, and the proximity of each outlet to high schools, recreational parks and public housing. Seven hundred and fifty tobacco outlets in the DC area, n=347 of which were randomly selected for inspection by the Synar Inspection Program in 2009-2010. The presence of tobacco advertisements on the interior and exterior of each outlet, and illicit tobacco sales to Synar Inspection Program youth volunteers. The presence of tobacco advertisements on the exterior of gas stations was much greater than on other retail store types (OR=6.68; 95% CI 4.05 to 11.01), as was the absence of any advertisements at bars or restaurants that sold tobacco (OR=0.33; 95% CI 0.22 to 0.52). Exterior tobacco advertisements were also more likely in predominantly African-American areas of the city (OR=3.11; 95% CI 2.28 to 4.25), and particularly likely on storefronts located closer to parks (OR=1.87; 95% CI 1.06 to 3.28). Illicit sales to minors were more common at gas stations (OR=3.01; 95% CI 1.5 to 6.3), outlets that displayed exterior tobacco advertisements closer to parks (OR=3.36; 95% CI 1.38 to 8.21), and outlets located closer to high schools in majority African-American block groups (OR=1.29; 95% CI 1.07 to 1.58). Findings demonstrate that while illicit tobacco sales to minors are occurring at acceptably low rates by Synar standards, illicit sales vary considerably by retail store type, advertising approach and proximity to high schools, parks and African-American residential areas. Future work may help inform regulatory efforts to reduce youth access at the neighbourhood, city, state and national levels. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Comprehensive energy and economic analyses on a zero energy house versus a conventional house

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, L. [School of Architecture, Tianjin University, Tianjin, 300072 (China); Hurt, R.; Correa, D.; Boehm, R. [Center for Energy Research, University of Nevada, Las Vegas, NV 89154 (United States)

    2009-09-15

    A zero energy house (ZEH) was built side by side with a baseline house in suburban Las Vegas. Actual energy performance measurements were carried out on the incorporated energy saving features and solar applications. The data show that a radiant barrier and a water-cooled air conditioner are major contributors to the energy savings, while an insulated floor slab and thermal mass walls are not effective for energy-conservation during cooling periods. Photovoltaic roof tiles produce enough green power to cover the use in the ZEH, and the solar water heater can reach a peak efficiency of 80%. The energy saving contribution of each incorporated component was obtained using Energy10 and eQUEST3.6 models, and then these codes were used for economic application evaluation. The two analysis codes yield similar results that compare well with the actual building performance data. Four items are clearly economically valuable for these applications: high performance windows, compact fluorescent lights, highly-insulated roofs and air conditioners with water-cooled condensers. PV tiles show a good financial return when rebates are considered. The Integrated Collector Storage (ICS) unit has a high efficiency but with a little higher thermal price. Thermal mass walls are too costly to have wide market appeal. (author)

  2. CFD Study of Industrial FCC Risers: The Effect of Outlet Configurations on Hydrodynamics and Reactions

    Directory of Open Access Journals (Sweden)

    Gabriela C. Lopes

    2012-01-01

    Full Text Available Fluid catalytic cracking (FCC riser reactors have complex hydrodynamics, which depend not only on operating conditions, feedstock quality, and catalyst particles characteristics, but also on the geometric configurations of the reactor. This paper presents a numerical study of the influence of different riser outlet designs on the dynamic of the flow and reactor efficiency. A three-dimensional, three-phase flow model and a four-lump kinetic scheme were used to predict the performance of the reactor. The phenomenon of vaporization of the liquid oil droplets was also analyzed. Results showed that small changes in the outlet configuration had a significant effect on the flow patterns and consequently, on the reaction yields.

  3. Prediction of liquid metal alloy radiant properties from measurements of the Hall coefficient and the direct current resistivity

    International Nuclear Information System (INIS)

    Havstad, M.A.; Qiu, T.

    1995-04-01

    The thermal radiative properties of high temperature solid and liquid metal alloys are particularly useful to research and development efforts in laser cladding and machining, electron beam welding and laser isotope separation. However the cost, complexity, and difficulty of measuring these properties have forced the use of crude estimates from the Hagen-Rubens relation, the Drude relations, or extrapolation from low temperature or otherwise flawed data (e.g., oxidized). The authors have found in this work that published values for the Hall coefficient and the electrical resistivity of liquid metal alloys can provide useful estimates of the reflectance and emittance of some groups of binary liquid metal and high temperature solid alloys. The estimation method computes the Drude free electron parameters, and thence the optical constants and the radiant properties from the dependence of the Hall coefficient and direct current resistivity on alloy composition (the Hall coefficient gives the free electron density and the resistivity gives the average time between collisions). They find that predictions of the radiant properties of molten cerium-copper alloy, which use the measured variations in the Hall coefficient and resistivity (both highly nonlinear) as a function of alloy fraction (rather than linear combinations of the values of the pure elements) yield a good comparison to published measurements of the variation of the normal spectral emittance (a different but also nonlinear function) of cerium-copper alloy at the single wavelength available for comparison, 0.645 μm. The success of the approach in the visible range is particularly notable because one expects a Drude based approach to improve with increasing wavelength from the visible into the infrared. Details of the estimation method, the comparison between the calculation and the measured emittance, and a discussion of what groups of elements may also provide agreement is given

  4. Noise and DC balanced outlet temperature signals for monitoring coolant flow in LMFBR fuel elements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1977-01-01

    Local cooling disturbances in LMFBR fuel elements may have serious safety implications for the whole reactor core. They have to be detected reliably in an early stage of their formation therefore. This can be accomplished in principle by individual monitoring of the coolant flow rate or the coolant outlet temperature of the sub-assemblies with high precision. In this paper a method is proposed to increase the sensitivity of outlet temperature signals to cooling disturbances. Using balanced temperature signals provides a means for eliminating the normal variations from the original signals which limit the sensitivity and speed of response to cooling disturbances. It is shown that a balanced signal can be derived easily from the original temperature signal by subtracting an inlet temperature and a neutron detector signal with appropriate time shift. The method was tested with tape-recorded noise signals of the KNK I reactor at Karlsruhe. The experimental results confirm the theoretical predictions. A significant reduction of the uncertainty of measured outlet temperatures was achieved. This enables very sensitive and fast response monitoring of coolant flow. Furthermore, it was found that minimizing the variance of the balanced signal offers the possibility for a rough determination of the heat transfer coefficient of the fuel rods during normal reactor operation at power. (author)

  5. Historical changes and recent energy saving potential of residential heating in Korea

    International Nuclear Information System (INIS)

    Yeo, M.-S.; Yang, I.-H.; Kim, K.-W.

    2003-01-01

    The residential heating method in Korea underwent various phases of development to reach the current system. The first phase was the traditional Ondol (the traditional under-floor heating system in Korea), where the floor was heated by the circulation of hot gas produced by a fire furnace (before the 1950s). The second phase involved the use of the modified anthracite coal Ondol, for which the fire furnace was modified for briquette use (from the early 1950s to the late 1970s). The third phase involved the use of hot water radiant floor heating with embedded tubes (from the late 1970s). This paper presents insights into the problem of current residential heating in Korea and the general aspects of heating energy savings by tracing the history of residential heating in Korea and analyzing related data. The results show that modern apartment buildings with hot water radiant floor heating (the third phase) yield less heat loss due to the tighter envelope, but also yield higher energy consumption than the traditional Ondol heating housing (the first phase). Because of an inefficient system and lack of thermal insulation of the traditional Ondol heating housing, Ondol heating was used to heat occupants sitting directly on the floor, keeping lower room temperature and higher floor surface temperature. So the range of comfortable floor temperature for Korean people is higher and this unique comfort sense is related to energy consumption in modern apartment housing. As a result, several energy saving methods were found such as reducing the total floor heating area or zoning the floor area, receiving continuous heat supply, and installing a delicate control system and metering devices. (author)

  6. Radiation and the evolution of life

    International Nuclear Information System (INIS)

    Gentner, N.E.; Myers, D.K.

    1980-08-01

    A general review is presented of the nature of various forms of radiation; radiant energy which reaches the earth from the sun; the role of this energy in prebiotic chemical evolution; current ideas on the origin of life; the dependence of living organisms upon radiant energy; the mechanisms responsible for the evolution of life, from the viewpoint of modern genetics and molecular biology; the biological consequences of alterations in the genetic material; and the role of ionizing radiation in production of genetic changes and in evolution. In the final analysis, the biosynthetic processes of life are driven by radiant energy from the sun. This overview is necessarily focussed on the infrared, visible and ultraviolet regions of the solar output spectrum since these particular radiations are responsible for most of the radiant energy that reaches the earth's surface. Ionizing radiation appears to have played at best a minor role in biological evolution. Small increments in the amounts of ionizing radiation are therefore unlikely to have a significant effect on life or its evolution. (auth)

  7. Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yan; Song, Zhen; Loftness, Vivian; Ji, Kun; Zheng, Sam; Lasternas, Bertrand; Marion, Flore; Yuebin, Yu

    2012-10-15

    We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IWn). The advanced control program was then installed in the IWn control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building

  8. Tobacco outlet density and converted versus native non-daily cigarette use in a national US sample.

    Science.gov (United States)

    Kirchner, Thomas R; Anesetti-Rothermel, Andrew; Bennett, Morgane; Gao, Hong; Carlos, Heather; Scheuermann, Taneisha S; Reitzel, Lorraine R; Ahluwalia, Jasjit S

    2017-01-01

    Investigate whether non-daily smokers' (NDS) cigarette price and purchase preferences, recent cessation attempts, and current intentions to quit are associated with the density of the retail cigarette product landscape surrounding their residential address. Cross-sectional assessment of N=904 converted NDS (CNDS). who previously smoked every day, and N=297 native NDS (NNDS) who only smoked non-daily, drawn from a national panel. Kernel density estimation was used to generate a nationwide probability surface of tobacco outlets linked to participants' residential ZIP code. Hierarchically nested log-linear models were compared to evaluate associations between outlet density, non-daily use patterns, price sensitivity and quit intentions. Overall, NDS in ZIP codes with greater outlet density were less likely than NDS in ZIP codes with lower outlet density to hold 6-month quit intentions when they also reported that price affected use patterns (G 2 =66.1, ppurchase locations (G 2 =85.2, pprice influenced the amount they smoke (G 2 =43.9, pprices (G 2 =59.3, pprice affected their cigarette brand choice compared with those in ZIP codes with lower density. This paper provides initial evidence that the point-of-sale cigarette environment may be differentially associated with the maintenance of CNDS versus NNDS patterns. Future research should investigate how tobacco control efforts can be optimised to both promote cessation and curb the rising tide of non-daily smoking in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region.

    Science.gov (United States)

    Hill, Jennie L; Chau, Clarice; Luebbering, Candice R; Kolivras, Korine K; Zoellner, Jamie

    2012-09-06

    Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES) peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention strategies targeting obesity.

  10. Does availability of physical activity and food outlets differ by race and income? Findings from an enumeration study in a health disparate region

    Directory of Open Access Journals (Sweden)

    Hill Jennie L

    2012-09-01

    Full Text Available Abstract Background Low-income, ethnic/racial minorities and rural populations are at increased risk for obesity and related chronic health conditions when compared to white, urban and higher-socio-economic status (SES peers. Recent systematic reviews highlight the influence of the built environment on obesity, yet very few of these studies consider rural areas or populations. Utilizing a CBPR process, this study advances community-driven causal models to address obesity by exploring the difference in resources for physical activity and food outlets by block group race and income in a small regional city that anchors a rural health disparate region. To guide this inquiry we hypothesized that lower income and racially diverse block groups would have fewer food outlets, including fewer grocery stores and fewer physical activity outlets. We further hypothesized that walkability, as defined by a computed walkability index, would be lower in the lower income block groups. Methods Using census data and GIS, base maps of the region were created and block groups categorized by income and race. All food outlets and physical activity resources were enumerated and geocoded and a walkability index computed. Analyses included one-way MANOVA and spatial autocorrelation. Results In total, 49 stores, 160 restaurants and 79 physical activity outlets were enumerated. There were no differences in the number of outlets by block group income or race. Further, spatial analyses suggest that the distribution of outlets is dispersed across all block groups. Conclusions Under the larger CPBR process, this enumeration study advances the causal models set forth by the community members to address obesity by providing an overview of the food and physical activity environment in this region. This data reflects the food and physical activity resources available to residents in the region and will aid many of the community-academic partners as they pursue intervention

  11. Personal values, marketing attitudes and nutrition trust are associated with patronage of convenience food outlets in the Asia-Pacific region: a cross-sectional study.

    Science.gov (United States)

    De Jong, Breanna; Worsley, Anthony; Wang, Wei Chun; Sarmugam, Rani; Pham, Quynh; Februhartanty, Judhiastuty; Ridley, Stacey

    2017-02-16

    An online cross-sectional survey examined the relationships between the demographic characteristics, personal values, trust in sources of nutrition information and the use of convenience food outlets among middle-class household food providers in the Asia-Pacific region. The survey was administered to 3945 household food providers in Melbourne, Singapore, Shanghai, Vietnam and Indonesia in late 2013. Information about demographics, personal values, trust in sources of nutrition information and use of convenience food outlets was elicited. Exploratory factor analysis, two-step clustering and logistic regression were employed. The analyses found that the use of convenience food outlets was positively related to hedonist values and trust in food industry sources of nutrition information. However, lesser use of convenience food outlets and trust in health sources of nutrition information was associated with traditional (community-oriented) values. Further replication and extension of these findings would be useful. However, they suggest that improvements in the quality of foods sold in convenience food outlets combined with stronger regulation of food marketing and long-term food education are required.

  12. Water recovery and air humidification by condensing the moisture in the outlet gas of a proton exchange membrane fuel cell stack

    International Nuclear Information System (INIS)

    Wan, Z.M.; Wan, J.H.; Liu, J.; Tu, Z.K.; Pan, M.; Liu, Z.C.; Liu, W.

    2012-01-01

    Humidification is one of the most important factors for the operation of proton exchange membrane fuel cell (PEMFC). To maintain the membrane at hydrated state, plenty of water is needed for the state-of-the-art of PEMFC technology, especially in large power applications or long time operation. A condenser is introduced to separate liquid water from the air outlet for air self-sufficient in water of the stack in this study. The condensed temperature at the outlet of the condenser and water recovered amount for air self-sufficient in water are investigated theoretically and experimentally. It is shown that the condensed temperature for air self-sufficient in water is irrelevant with the working current of the stack. When the condenser outlet temperature was above the theoretical line, recovery water was not sufficient for the air humidification. On the contrary, it is sufficient while the temperature was below the theoretical line. It is also shown that when the moisture is sufficiently cooled, large amount water can be separated from the outlet gas, and it increased almost linearly with the time. With the introduction of the condenser, the recovered amount of water can easily satisfy the air self-sufficient in water by condensing the outlet gas to a proper temperature. - Highlights: ► We introduce a condenser to separate liquid water from the air outlet in the stack. ► The mechanism of air self-sufficient in water by condensing gas is presented. ► The condensed temperature and water recovered amount are investigated. ► An experiment is present to validate simplicity and feasibility of the criterion. ► The criterion for air humidification is used for choosing the condenser.

  13. Effect of short-term outlet obstruction on rat bladder nerve density and contractility

    NARCIS (Netherlands)

    Barendrecht, M. M.; Chichester, P.; Michel, M. C.; Levin, R. M.

    2007-01-01

    1 The present study was designed to investigate the relationship between innervation density and contractile responses to field stimulation and exogenous agonists at early time points after induction of bladder outlet obstruction (BOO) in rats. 2 When compared with sham-operated animals, 1, 3 and 7

  14. Electromagnetic wave energy conversion research

    Science.gov (United States)

    Bailey, R. L.; Callahan, P. S.

    1975-01-01

    Known electromagnetic wave absorbing structures found in nature were first studied for clues of how one might later design large area man-made radiant-electric converters. This led to the study of the electro-optics of insect dielectric antennae. Insights were achieved into how these antennae probably operate in the infrared 7-14um range. EWEC theoretical models and relevant cases were concisely formulated and justified for metal and dielectric absorber materials. Finding the electromagnetic field solutions to these models is a problem not yet solved. A rough estimate of losses in metal, solid dielectric, and hollow dielectric waveguides indicates future radiant-electric EWEC research should aim toward dielectric materials for maximum conversion efficiency. It was also found that the absorber bandwidth is a theoretical limitation on radiant-electric conversion efficiency. Ideally, the absorbers' wavelength would be centered on the irradiating spectrum and have the same bandwith as the irradiating wave. The EWEC concept appears to have a valid scientific basis, but considerable more research is needed before it is thoroughly understood, especially for the complex randomly polarized, wide band, phase incoherent spectrum of the sun. Specific recommended research areas are identified.

  15. A Simulation Study on the Performance of Radiant Ceilings Combined with Free-Hanging Horizontal Sound Absorbers

    DEFF Research Database (Denmark)

    Kazanci, Ongun Berk; Domínguez, L. Marcos; Rage, Niels

    2018-01-01

    using TABS, most building simulation models assume an uncovered ceiling; however, this might not be the case in practice, due to the use of free-hanging horizontal (or vertical) sound absorbers for the control of room acoustic conditions. The use of sound absorbers will decrease the performance...... of radiant ceiling cooling systems. Therefore, the quantification of the effects during the design phase is important for predicting the resulting thermal indoor environment and for system dimensioning. In this study, a two-person office room equipped with TABS was simulated using a commercially available...... simulation software with a recently developed plug-in that allows simulating the effects of horizontal sound absorbers on the performance of TABS and on the thermal indoor environment. The change in thermal indoor environment and in performance of TABS were quantified, and the simulation results were...

  16. Numerical Simulation of Two-branch Hot Gas Mixing at Reactor Outlet of HTR-PM

    International Nuclear Information System (INIS)

    Hao Pengefei; Zhou Yangping; Li Fu; Shi Lei; He Heng

    2014-01-01

    A series of two-branch model experiment has been finished to investigate the thermal mixing efficiency of the HTR-PM reactor outlet. This paper introduces the numerical simulation on the design of thermal mixing structure of HTR-PM and the test facility with Fluent software. The profiles of temperature, pressure and velocity in the mixing structure design and the test facility are discussed by comparing with the model experiment results. The numerical simulation results of the test facility have good agreement to the experiment results. In addition, the thermal-fluid characters obtained by numerical simulation show the thermal mixing structure of HTR-PM has similarity with the test facility. Finally, it is concluded that the thermal mixing design at HTR-PM reactor outlet can fulfilled the requirements for high thermal mixing efficiency and appropriate pressure drop. (author)

  17. Occurrence and seasonal variations of per- and polyfluoroalkyl substances (PFASs) including fluorinated alternatives in rivers, drain outlets and the receiving Bohai Sea of China.

    Science.gov (United States)

    Chen, Hong; Han, Jianbo; Zhang, Can; Cheng, Jiayi; Sun, Ruijun; Wang, Xiaomeng; Han, Gengchen; Yang, Wenchao; He, Xin

    2017-12-01

    A simultaneous sampling campaign was undertaken to study the pollution by 21 per- and polyfluoroalkyl substances (PFASs) in rivers, drain outlets and their receiving Bohai Sea of China. Chlorinated polyfluoroalkyl ether sulfonic acids (Cl-PFESAs) are being used as fluorinated alternatives and they were included in this study. In comparison with other regions and countries, high concentrations of ∑ 21 PFASs in seawater samples from the Bohai Sea, ranging from 5.03 to 41 700 ng/L (median: 64.8 ng/L), were observed. The spatial distribution of PFAS levels in this sea area was in the ranking of Laizhou Bay > Liaodong Bay > Bohai Bay > other sea areas. By comparing the levels and composition profiles of PFASs in the seawater and their sources (rivers and drain outlets), it was concluded that rivers and drain outlets are the primary sources of PFAS contamination to the Bohai Sea. These PFAS levels varied seasonally among the rivers and drain outlets, but statistically significant changes were not observed. Levels of 6:2 and 8:2 Cl-PFESAs in rivers, drain outlets and receiving sea were firstly reported in the present study. Relatively high concentrations of 6:2 Cl-PFESA were found in drain outlets, ranging from below method limits of quantification (MLQ) to 7600 ng/L, but 8:2 Cl-PFAES detection was infrequent and all median concentration below MLQ. Mass discharges to the sea of 6:2 Cl-PFESA from rivers and drain outlets to the sea were estimated to be 37 and 17 kg/y, respectively. Copyright © 2017. Published by Elsevier Ltd.

  18. Evaluating Capability of Devils Lake Emergency Outlets in Lowering Lake Water Levels While Controlling flooding Damage to Downstream

    Science.gov (United States)

    Shabani, A.; Zhang, X.

    2017-12-01

    Devils Lake is an endorheic lake locate in the Red River of the North Basin with a natural outlet at a level of 444.7 meters above the sea level flowing into the Sheyenne River. Historical accumulation of salts has dramatically increased the concentration of salts in the lake, particularly of the sulfates, that are much greater than the surrounding water bodies. Since 1993, the lake water level has risen by nearly 10 meters and caused extensive flooding in the surrounding area, and greatly increased the chance of natural spillage to the Sheyenne River. To mitigate Devils Lake flooding and to prevent its natural spillage, two outlets were constructed at the west and east sides of the lake to drain the water to the Sheyenne River in a controlled fashion. However, pumping water from Devils Lake has degraded water quality of the Sheyenne River. In an earlier study, we coupled Soil and Water Assessment Tools (SWAT) and CE-QUAL-W2 models to investigate the changes of sulfate distribution as the lake water level rises. We found that, while operating the two outlets has lowered Devils Lake water level by 0.7 meter, it has also significantly impaired the Sheyenne River water quality, increasing the Sheyenne River average sulfate concentration from 105 to 585 mg l-1 from 2012 to 2014 In this study, we investigate the impact of the outlets on the Sheyenne River floodplain by coupling SWAT and HEC-RAS model. The SWAT model performed well in simulating daily streamflow in the Sheyenne River with R2>0.56 and ENS > 0.52. The simulated water depths and floodplain by HEC-RAS model for the Sheyenne River agreed well with observations. Operating the outlets from April to October can draw down the Devil Lake water level by 0.45 m, but the drained water would almost double the extension of the Sheyenne River floodplain and elevate the sulfate concentration in the Sheyenne River above the 450 mg l-1 North Dakota sulfate concentration standard for stream class I. Operating the outlets is

  19. Fast-food outlets and grocery stores near school and adolescents' eating habits and overweight in Finland.

    Science.gov (United States)

    Virtanen, Marianna; Kivimäki, Hanne; Ervasti, Jenni; Oksanen, Tuula; Pentti, Jaana; Kouvonen, Anne; Halonen, Jaana I; Kivimäki, Mika; Vahtera, Jussi

    2015-08-01

    Environmental factors may affect adolescents' eating habits and thereby body weight. However, the contribution of school neighbourhood environment is poorly understood. This study examined the association between proximity of a fast-food outlet or grocery store to school and adolescents' eating habits and overweight. Participants were 23 182 adolescents (mean age 15 years) who responded to a classroom survey in 181 lower secondary schools in Finland (2008-09). School location was linked to data on distance from school to the nearest fast-food outlet or grocery store (≤100 m, 101-500 m, >500 m) using global positioning system-coordinate databases. Outcomes were irregular eating habits (skipping breakfast, skipping free school lunch, skipping free school-provided snacks and not having family dinners), the accumulation of these habits and overweight, including obesity (body mass index ≥ 25 kg/m(2)). Thirteen percentage of the participants were overweight. Having a fast-food outlet or grocery store near school was associated with skipping often breakfast and free school lunch, and the accumulation of irregular eating habits. The proximity of a fast-food outlet or grocery store was associated with a 1.25-fold (95% confidence interval 1.03-1.52) risk of overweight among adolescent with a low socioeconomic status but not among those with higher socioeconomic status. This association was partly (12%) explained by the accumulation of irregular eating habits. Among adolescents from low socioeconomic background, the presence of fast-food retailers near schools is associated with accumulation of irregular eating habits and greater overweight. These findings suggest that obesogenic school neighbourhoods may contribute to social inequalities in overweight. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  20. Outlet strut fracture and leaflet escape of Bjork-Shiley convexo-concave valve.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Hideo; Sakoda, Naoya; Hattori, Shigeru; Kawabata, Takuya; Saiki, Munehiro; Fujita, Yasufumi; Yunoki, Keiji; Hisamochi, Kunikazu; Mine, Yoshinari

    2017-06-01

    Prosthetic valve fracture is a serious complication and may arise in patient post-valve replacement. We experienced an outlet strut fracture and leaflet escape of a Bjork-Shiley convexo-concave valve. We performed an emergency redo mitral valve replacement and successfully retrieved the fractured strut and escaped leaflet from superficial femoral artery and the abdominal aorta. The patient showed an uneventful postoperative recovery.

  1. Super Energy Efficient Design (S.E.E.D.) Home Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    German, A. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Backman, C. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Weitzel, E. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States); Springer, D. [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2012-12-01

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the “Super Energy Efficient Design” (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

  2. Comparison of fast food consumption and dietary guideline practices for children and adolescents by clustering of fast food outlets around schools in the Gyeonggi area of Korea.

    Science.gov (United States)

    Joo, Soonnam; Ju, Seyoung; Chang, Hyeja

    2015-01-01

    This study investigated the distribution density of fast food outlets around schools, and the relationship between dietary health of children and adolescents and the density of fast food outlets in Korea. A distribution map of fast food outlets was drawn by collecting information on 401 locations of 16 brands within a 15-minute walk (800 meter) of 342 elementary and secondary schools in Suwon, Hwaseong and Osan. A questionnaire was used to gather data on the dietary life of 243 sixth and eighth grade students at eight schools. Schools in the upper 20% and lower 20% of the fast food outlet distribution were classified as high-density and low-density groups, respectively. The practice rate of dietary guidelines published by the Health and Welfare Ministry and the fast food consumption pattern of children and adolescents from low and high density groups were determined. The number of schools with a fast food outlet within 200 meters or in the Green Food Zone around its location was 48 of 189 (25.4%) in Suwon and 14 of 153 (9.2%) in Hwaseong and Osan. Students in the low-density group visited fast food outlets less often than those in the high-density group (pfast food outlets within 200 meters of schools was useful for identifying the effectiveness of the Green Food Zone Act and nutrition education programs.

  3. A New Hybrid Bathroom System Based on Energy Saving Concept

    Directory of Open Access Journals (Sweden)

    Cui Bo-wen

    2016-01-01

    Full Text Available Based on the characteristics of hot water supply in bathroom, this article proposes a new hybrid energy hot water supply system. The programmable logic controller(PLC as the master controller was adopted in this system, which could automatically detect and storage main thermal physical of the system, such as temperature, water level, solar radiation intensity, power consumption and so on. The active thermal utilization technology of solar energy, air-source heat pump technology, solar energy intensive natural ventilation technology and low temperature hot water floor radiant heating technology were organically integrated in this system, which has the advantages of energy conservation and environment protection, high automation, safe and reliable operation, etc. At the same time, it can make good use of electric power cost between on-peak and off-peak, and promote the optimal allocation of power resources and reduce the cost, which can achieve the goal of intelligent control and energy saving.

  4. Marketing Communications Research On Food & Beverage Outlets Of Moevenpick Hotel Saigon

    OpenAIRE

    Hoang Minh, Tam

    2012-01-01

    The purpose of this thesis was to conduct a marketing communications research on Food & Beverage Outlets of Moevenpick hotel Saigon. Besides, a short description of consumer rating on F&B service quality was other mission specifically assigned by the commissioned party. The research provided general information about both targeted potential customers from surrounding areas and current hotel guest and restaurant diner. Next was the analysis derived from the customer survey’s result, the ran...

  5. A Comparative Analysis of the Distributions of KFC and McDonald’s Outlets in China

    Directory of Open Access Journals (Sweden)

    Yikang Rui

    2016-03-01

    Full Text Available Mainland China has become one of the most important markets for international fast-food chains over the past decade. To study the regional spread of KFC and McDonald’s outlets in Chinese cities, the correlation of their distributions and degree of market expansion were explored and compared to analyze both the local and the global spatial autocorrelations. A geographically weighted Poisson regression model was also used to examine the influence of demographic, economic, and geographic factors on their spatial distributions. The findings of this comparative study reveal the site selection criteria at the city level by studying the differences and similarities in outlet distributions for KFC and McDonald’s. The presented results can guide other chains to enhance business location planning and formulate regional development policy.

  6. Energy-dense fast food products cost less: an observational study of the energy density and energy cost of Australian fast foods.

    Science.gov (United States)

    Wellard, Lyndal; Havill, Michelle; Hughes, Clare; Watson, Wendy L; Chapman, Kathy

    2015-12-01

    To examine the association between energy cost and energy density of fast food products. Twenty Sydney outlets of the five largest fast food chains were surveyed four times. Price and kilojoule data were collected for all limited-time-only menu items (n=54) and a sample of standard items (n=67). Energy cost ($/kilojoule) and energy density (kilojoules/gram) of menu items were calculated. There was a significant inverse relationship between menu item energy density and energy cost (pFast food chains could provide a wider range of affordable, lower-energy foods, use proportional pricing of larger serve sizes, or change defaults in meals to healthier options. More research is required to determine the most effective strategy to reduce the negative impact of fast food on the population's diet. Current pricing in the fast food environment may encourage unhealthier purchases. © 2015 Public Health Association of Australia.

  7. OPERABILITY RATE OF DISTAL GASTRIC CANCER AND THE EFFECT OF GASTRIC OUTLET OBSTRUCTION IN THE OPERABILITY RATE AND POSTOPERATIVE OUTCOME- A RETROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Rajesh T. R

    2017-10-01

    Full Text Available BACKGROUND Stomach cancer is the fourth most common malignancy in the world. 1 Except in countries where screening for stomach cancer is prevalent, most of the distal stomach tumours are diagnosed at advanced stage. Gastric outlet obstruction is usually believed to be a sign of locally-advanced disease. Complete surgical removal of the disease (R0 is the only potentially curative treatment for resectable gastric cancer. The aim of the study is to finda The operability rate of gastric cancer in our institution and the incidence of Gastric Outlet Obstruction (GOO in patients undergoing gastrectomy for distal gastric cancer. b To compare the postoperative outcome in patients with gastric outlet obstruction and those without gastric outlet obstruction. c To see if the histology of the tumour has any role in the development of GOO. MATERIALS AND METHODS This is a retrospective study. The study includes patients who were admitted with carcinoma stomach and underwent operative or nonoperative treatment in our institution during 2013 to 2015. RESULTS Overall operability rate was 45.8%. Operable patients in the GOO group were 47%. Operability in the no outlet obstruction group were 45%. Data shows a slightly increased predilection for GOO in diffuse and mixed type of tumours (statistically not significant. Intestinal tumours had significant rate of anaemia compared to diffuse tumours (p <0.005. Overall mortality was 6.7%. Mortality is higher in the GOO group (8.8%. CONCLUSION (a. Operability rate of distal gastric cancer in our institution is 45.8%. (b. Incidence of gastric outlet obstruction in patients undergoing gastrectomy is 38.2%. (c. Presence of gastric outlet obstruction does not influence operability rate (47% vs. 45%. (d. Morbidity and mortality after distal radical gastrectomy is comparable in both groups. (e. Both intestinal and diffuse histology have equal incidence of GOO. (f. Chronic blood loss and incidence of anaemia is more in

  8. Energy sources of yoghurt bacteria and enhancement of their ...

    African Journals Online (AJOL)

    The energy sources of yoghurt bacteria (Streptococcus thermophilus and Lactobacillus bulgaricus) were examined with a focus on probable impact of sucrose on their galactose uptake. Yoghurt bacteria were isolated from samples of yoghurt which were purchased from different outlets and kept under refrigeration ...

  9. Quantifying the Impacts of Outlet Control Structures on Lake Hydrology and Ecology

    Science.gov (United States)

    Budd, B. M.; Kendall, A. D.; Martin, S. L.; Hyndman, D. W.

    2012-12-01

    There have been limited studies of the impacts of lake level control structures on stream ecology and lake property erosion. We examine the influence of historical lake level management strategies on Higgins Lake in Michigan, which is regionally known for recreation, fisheries, and scenery. Lake control structures have potentially increased shoreline erosion and seasonally-reduced flow through the outlets, likely impacting fish habitat. Concerns over these issues spurred local land owners to seek a study on the possible hydrologic and ecological impacts of the removal or modification of the control structure. Bathymetry maps are fundamental to understanding and managing lake ecosystems. From the 1930's through the 1950's, these maps were developed for thousands of Michigan inland lakes using soundings lowered through holes cut in winter lake ice. Increased land use change and alterations of lake outlets have likely modified erosion and sedimentation rates of these lake systems. Our research includes bathymetry surveys of Higgins Lake using an Acoustic Doppler Current Profiler (ADCP) and side-scan sonar. The new higher-resolution bathymetry serves as the basis for simulating impacts of potential changes in lake management, on a verity of inpoint including shoreline position and fish habitat.

  10. High temperature ceramic-tubed reformer

    Science.gov (United States)

    Williams, Joseph J.; Rosenberg, Robert A.; McDonough, Lane J.

    1990-03-01

    The overall objective of the HiPHES project is to develop an advanced high-pressure heat exchanger for a convective steam/methane reformer. The HiPHES steam/methane reformer is a convective, shell and tube type, catalytic reactor. The use of ceramic tubes will allow reaction temperature higher than the current state-of-the-art outlet temperatures of about 1600 F using metal tubes. Higher reaction temperatures increase feedstock conversion to synthesis gas and reduce energy requirements compared to currently available radiant-box type reformers using metal tubes. Reforming of natural gas is the principal method used to produce synthesis gas (primarily hydrogen and carbon monoxide, H2 and CO) which is used to produce hydrogen (for refinery upgrading), methanol, as well as several other important materials. The HiPHES reformer development is an extension of Stone and Webster's efforts to develop a metal-tubed convective reformer integrated with a gas turbine cycle.

  11. Theoretical impacts of a range of major tobacco retail outlet reduction interventions: modelling results in a country with a smoke-free nation goal.

    Science.gov (United States)

    Pearson, Amber L; van der Deen, Frederieke S; Wilson, Nick; Cobiac, Linda; Blakely, Tony

    2015-03-01

    To inform endgame strategies in tobacco control, this study aimed to estimate the impact of interventions that markedly reduced availability of tobacco retail outlets. The setting was New Zealand, a developed nation where the government has a smoke-free nation goal in 2025. Various legally mandated reductions in outlets that were phased in over 10 years were modelled. Geographic analyses using the road network were used to estimate the distance and time travelled from centres of small areas to the reduced number of tobacco outlets, and from there to calculate increased travel costs for each intervention. Age-specific price elasticities of demand were used to estimate future smoking prevalence. With a law that required a 95% reduction in outlets, the cost of a pack of 20 cigarettes (including travel costs) increased by 20% in rural areas and 10% elsewhere and yielded a smoking prevalence of 9.6% by 2025 (compared with 9.9% with no intervention). The intervention that permitted tobacco sales at only 50% of liquor stores resulted in the largest cost increase (∼$60/pack in rural areas) and the lowest prevalence (9.1%) by 2025. Elimination of outlets within 2 km of schools produced a smoking prevalence of 9.3%. This modelling merges geographic, economic and epidemiological methodologies in a novel way, but the results should be interpreted cautiously and further research is desirable. Nevertheless, the results still suggest that tobacco outlet reduction interventions could modestly contribute to an endgame goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Energy mastery, 30 years later. New challenges in the sustainable development context

    International Nuclear Information System (INIS)

    Padet, J.; Bissieux, C.; Padet, C.; Lachi, M.; Pron, H.

    2005-01-01

    The main topic of the 2005 issue of the annual congress of the French society of thermal engineering (SFT) is the energy mastery as a response to the sustainable development challenge. These proceedings gather 130 publications shared between 5 sessions dealing with: transfers in multiphase environments (two-phase and phase change); convective transfers (natural, mixed, forced and jets); coupled transfers (radiant, combustion, plasmas, porous media, drying); thermophysical properties (micro-thermal, interfaces, measurements, identification); thermal systems (exchangers, processes, energetics). Among these, two articles are relevant for the INIS database, one treats of the thermal problems encountered with thermonuclear fusion. and the other deals with the scientific policy of the French agency of environment and energy mastery (Ademe). (J.S.)

  13. Les débouchés énergétiques de l'agriculture de la Communauté Economique Européenne Energy Outlets for Agriculture in the European Economic Community

    Directory of Open Access Journals (Sweden)

    Becker J. J.

    2006-11-01

    Full Text Available L'agriculture de la Communauté Economique Européenne (CEE connaît une crise profonde au niveau de ses débouchés. Ainsi, même dans un contexte où l'indépendance énergétique n'est plus une préoccupation majeure, une production massive d'énergie par l'agriculture reste un projet à priori digne d'intérêt. Cette étude précise les modalités d'application concrètes d'une telle politique et tente une évaluation économique permettant d'apprécier la viabilité d'un tel schéma. Elle présente, en particulier, un positionnement par rapport aux solutions agricoles plus classiques actuellement mises en oeuvre et qui pourtant ne sont guère satisfaisantes. Agriculture in the EEC is in the midst of a deep crisis concerning its outlets. Even in a context where energy independence is no longer a major preoccupation, massive energy production by agriculture is still a problem worthy of interest, a priori. This article specifies concrete procedures for applying such a policy and tries to make an economic evaluation to assess the viability of such a scheme. In particular, it describes a position in relation to the most conventional agricultural solutions now being implemented and that are proving not to be very satisfactory.

  14. Got ACTs? Availability, price, market share and provider knowledge of anti-malarial medicines in public and private sector outlets in six malaria-endemic countries

    Directory of Open Access Journals (Sweden)

    O'Connell Kathryn A

    2011-10-01

    Full Text Available Abstract Background Artemisinin-based combination therapy (ACT is the first-line malaria treatment throughout most of the malaria-endemic world. Data on ACT availability, price and market share are needed to provide a firm evidence base from which to assess the current situation concerning quality-assured ACT supply. This paper presents supply side data from ACTwatch outlet surveys in Benin, the Democratic Republic of Congo (DRC, Madagascar, Nigeria, Uganda and Zambia. Methods Between March 2009 and June 2010, nationally representative surveys of outlets providing anti-malarials to consumers were conducted. A census of all outlets with the potential to provide anti-malarials was conducted in clusters sampled randomly. Results 28,263 outlets were censused, 51,158 anti-malarials were audited, and 9,118 providers interviewed. The proportion of public health facilities with at least one first-line quality-assured ACT in stock ranged between 43% and 85%. Among private sector outlets stocking at least one anti-malarial, non-artemisinin therapies, such as chloroquine and sulphadoxine-pyrimethamine, were widely available (> 95% of outlets as compared to first-line quality-assured ACT ( Conclusions These standardized, nationally representative results demonstrate the typically low availability, low market share and high prices of ACT, in the private sector where most anti-malarials are accessed, with some exceptions. The results confirm that there is substantial room to improve availability and affordability of ACT treatment in the surveyed countries. The data will also be useful for monitoring the impact of interventions such as the Affordable Medicines Facility for malaria.

  15. Evaluation of medicine retail outlets for sale of typhoid fever vaccine among adults in two urban and rural settings in western Kenya: a proof-of-concept study.

    Science.gov (United States)

    Ho, Julius; Odhiambo, Gladys; Meng'anyi, Lucy W; Musuva, Rosemary M; Mule, Joseph M; Alaly, Zakayo S; Odiere, Maurice R; Mwinzi, Pauline N; Ganley-Leal, Lisa

    2016-09-29

    Private sector medicine outlets are an important provider of health services across the developing world, and are an untapped means of distributing and selling vaccines outside of childhood immunization programs. The present study assessed the viability of medicine outlets (chemists and pharmacies) as potential channels for sale of vaccines. To evaluate the viability of the medicine outlet model, we partnered with nine outlets across urban and rural communities in western Kenya to sell a nurse-administered typhoid vaccine. Purchasers were surveyed to reveal market demographic characteristics, reasons for vaccine purchase, and sources of information about the program. Key informant interviews and focus group discussions defined acceptability, demand, and additional suggestions for improving this mechanism of selling and distributing vaccines. There was a higher than expected demand for the vaccine that resulted in stock-outs. Previous instance of typhoid, desire to prevent disease, affordable price and convenience were cited by most participants as main reasons for purchase of vaccine at the local outlet. The most common source of information on the vaccine sale was word-of-mouth and referral from friends. Longer vaccine sale duration, adequate stocking of vaccines and extended hours of administration in the evening to allow working individuals to buy vaccines were cited by participants as ways for improved participation in the future. This study demonstrated a high demand for vaccines at community medicine outlets. Important insights on how to improve and sustain such a program included extension of distribution time, education of outlet keepers, and minimizing vaccine stockouts. With improved social marketing, infrastructure mapping, education and pricing schemes, medicine outlets could become a sustainable avenue for selling adult vaccines in emerging markets for both routine and pandemic vaccines.

  16. Air demand estimation in bottom outlets with the particle finite element method. Susqueda Dam case study

    Science.gov (United States)

    Salazar, Fernando; San-Mauro, Javier; Celigueta, Miguel Ángel; Oñate, Eugenio

    2017-07-01

    Dam bottom outlets play a vital role in dam operation and safety, as they allow controlling the water surface elevation below the spillway level. For partial openings, water flows under the gate lip at high velocity and drags the air downstream of the gate, which may cause damages due to cavitation and vibration. The convenience of installing air vents in dam bottom outlets is well known by practitioners. The design of this element depends basically on the maximum air flow through the air vent, which in turn is a function of the specific geometry and the boundary conditions. The intrinsic features of this phenomenon makes it hard to analyse either on site or in full scaled experimental facilities. As a consequence, empirical formulas are frequently employed, which offer a conservative estimate of the maximum air flow. In this work, the particle finite element method was used to model the air-water interaction in Susqueda Dam bottom outlet, with different gate openings. Specific enhancements of the formulation were developed to consider air-water interaction. The results were analysed as compared to the conventional design criteria and to information gathered on site during the gate operation tests. This analysis suggests that numerical modelling with the PFEM can be helpful for the design of this kind of hydraulic works.

  17. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  18. Endoscopic magnetic gastroenteric anastomosis for palliation of malignant gastric outlet obstruction: a prospective multicenter study

    NARCIS (Netherlands)

    van Hooft, Jeanin E.; Vleggaar, Frank P.; Moine, Olivier Le; Bizzotto, Alessandra; Voermans, Rogier P.; Costamagna, Guido; Devière, Jacques; Siersema, Peter D.; Fockens, Paul

    2010-01-01

    Background: Palliation of malignant gastric outlet obstruction remains challenging. Although there are 2 established treatment options, ie, surgical gastrojejunostomy and endoscopic duodenal stent insertion, there is an ongoing search for a technique that would combine the safety and rapid effect of

  19. Modeling the transmitted and stored energy in multilayer protective clothing under low-level radiant exposure

    International Nuclear Information System (INIS)

    Su, Yun; He, Jiazhen; Li, Jun

    2016-01-01

    Highlights: • A numerical model from heating source to skin tissues through multilayer fabric system is developed. • The numerical model is comprehensively validated with experimental data. • The model is used to investigate the relationship between the transmitted and stored energy and the influencing factors. - Abstract: A finite difference model was introduced to simulate the transmitted and stored energy in firefighters' protective clothing exposed to low-level thermal radiation. The model domain consists of a three-layer fire-resistant fabric system (outer shell, moisture barrier, and thermal liner), the human skin, and the air gap between clothing and the skin. The model accounted for the relationship between the transmitted heat during the exposure and the discharged heat during the cooling-down period. The numerical model predictions were compared with experimental data. Additionally, the parameters that affect the transmitted and stored energy of protective clothing were investigated. The results demonstrate that for the typical multilayer firefighter protective clothing, the transmitted heat during exposure and the discharged heat after exposure totally determine the skin burn under low-level heat exposure, especially for third-degree skin burns. The findings obtained in this study can be used to engineer fabric systems that provide better protection for the stored thermal burn.

  20. Super Energy Efficiency Design (S.E.E.D.) Home Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    German, A.; Dakin, B.; Backman, C.; Weitzel, E.; Springer, D.

    2012-12-01

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

  1. A description of interventions promoting healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England: a systematic mapping and evidence synthesis.

    Science.gov (United States)

    Hillier-Brown, Frances C; Summerbell, Carolyn D; Moore, Helen J; Wrieden, Wendy L; Adams, Jean; Abraham, Charles; Adamson, Ashley; Araújo-Soares, Vera; White, Martin; Lake, Amelia A

    2017-01-19

    Ready-to-eat meals (to eat in, to take away or to be delivered) sold by food outlets are often more energy dense and nutrient poor compared with meals prepared at home, making them a reasonable target for public health intervention. The aim of the research presented in this paper was to systematically identify and describe interventions to promote healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England. A systematic search and sift of the literature, followed by evidence mapping of relevant interventions, was conducted. Food outlets were included if they were located in England, were openly accessible to the public and, as their main business, sold ready-to-eat meals. Academic databases and grey literature were searched. Also, local authorities in England, topic experts, and key health professionals and workers were contacted. Two tiers of evidence synthesis took place: type, content and delivery of each intervention were summarised (Tier 1) and for those interventions that had been evaluated, a narrative synthesis was conducted (Tier 2). A total of 75 interventions were identified, the most popular being awards. Businesses were more likely to engage with cost neutral interventions which offered imperceptible changes to price, palatability and portion size. Few interventions involved working upstream with suppliers of food, the generation of customer demand, the exploration of competition effects, and/or reducing portion sizes. Evaluations of interventions were generally limited in scope and of low methodological quality, and many were simple assessments of acceptability. Many interventions promoting healthier ready-to-eat meals (to eat in, to take away, or to be delivered) sold by specific food outlets in England are taking place; award-type interventions are the most common. Proprietors of food outlets in England that, as their main business, sell ready-to-eat meals, can be engaged in implementing

  2. Associations between Food Outlets around Schools and BMI among Primary Students in England: A Cross-Classified Multi-Level Analysis.

    Science.gov (United States)

    Williams, Julianne; Scarborough, Peter; Townsend, Nick; Matthews, Anne; Burgoine, Thomas; Mumtaz, Lorraine; Rayner, Mike

    2015-01-01

    Researchers and policy-makers are interested in the influence that food retailing around schools may have on child obesity risk. Most previous research comes from North America, uses data aggregated at the school-level and focuses on associations between fast food outlets and school obesity rates. This study examines associations between food retailing and BMI among a large sample of primary school students in Berkshire, England. By controlling for individual, school and home characteristics and stratifying results across the primary school years, we aimed to identify if the food environment around schools had an effect on BMI, independent of socio-economic variables. We measured the densities of fast food outlets and food stores found within schoolchildren's home and school environments using Geographic Information Systems (GIS) and data from local councils. We linked these data to measures from the 2010/11 National Child Measurement Programme and used a cross-classified multi-level approach to examine associations between food retailing and BMI z-scores. Analyses were stratified among Reception (aged 4-5) and Year 6 (aged 10-11) students to measure associations across the primary school years. Our multilevel model had three levels to account for individual (n = 16,956), home neighbourhood (n = 664) and school (n = 268) factors. After controlling for confounders, there were no significant associations between retailing near schools and student BMI, but significant positive associations between fast food outlets in home neighbourhood and BMI z-scores. Year 6 students living in areas with the highest density of fast food outlets had an average BMI z-score that was 0.12 (95% CI: 0.04, 0.20) higher than those living in areas with none. We found little evidence to suggest that food retailing around schools influences student BMI. There is some evidence to suggest that fast food outlet densities in a child's home neighbourhood may have an effect on BMI, particularly

  3. DEM study of granular discharge rate through a vertical pipe with a bend outlet in small absorber sphere system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tianjin, E-mail: tjli@tsinghua.edu.cn; Zhang, He; Liu, Malin; Huang, Zhiyong; Bo, Hanliang; Dong, Yujie

    2017-04-01

    Highlights: • The work concerns granular flow in a vertical pipe with a bend. • Discharge rate fluctuation in vertical pipe are mainly from velocity fluctuation. • Steady discharge rate decreases rapidly and saturates with μ{sub s} increasing. • Steady discharge rate W{sub s} still obey the 5/2 power law of pipe internal diameter. • A correlation developed for steady discharge rate for this new geometry. - Abstract: Absorber sphere pneumatic conveying is a special application of pneumatic conveying technique in the pebble bed High Temperature Gas-Cooled Reactor (HTGR or HTR). Granular discharge through a vertical pipe with a bend outlet is one of the control modes to determine solid mass flowrate which is an important parameter for the design of absorber sphere pneumatic conveying. Granular discharge rate through the vertical pipe with a bend outlet in the small absorber sphere system are investigated by discrete element method simulation. The effect of geometry parameters on discharge rate, the discharge rate fluctuation in the vertical pipe, and the effect of friction on steady discharge rate (W{sub s}) are analyzed and discussed. The phenomena of discharge rate fluctuation in the vertical pipe are observed, which are mainly resulted from the evolution of the average downward granular velocity. The steady discharge rate decreases rapidly with sliding friction coefficient increasing from 0.125 to 0.5, and gradually saturates with the friction coefficient further increasing from 0.5 to 1. It is interesting that the linear relation between W{sub s}{sup 2/5} and pipe internal diameter D with zero intercept are found for the vertical pipe discharge with a bend outlet, which is different from the orifice discharge through a hopper or silo with none-zero intercept. A correlation similar to Beverloo’s correlation is developed to predict the steady discharge rate through the vertical pipe with a bend outlet. These results are helpful for the design of sphere

  4. Associations between Food Outlets around Schools and BMI among Primary Students in England: A Cross-Classified Multi-Level Analysis.

    Directory of Open Access Journals (Sweden)

    Julianne Williams

    Full Text Available Researchers and policy-makers are interested in the influence that food retailing around schools may have on child obesity risk. Most previous research comes from North America, uses data aggregated at the school-level and focuses on associations between fast food outlets and school obesity rates. This study examines associations between food retailing and BMI among a large sample of primary school students in Berkshire, England. By controlling for individual, school and home characteristics and stratifying results across the primary school years, we aimed to identify if the food environment around schools had an effect on BMI, independent of socio-economic variables.We measured the densities of fast food outlets and food stores found within schoolchildren's home and school environments using Geographic Information Systems (GIS and data from local councils. We linked these data to measures from the 2010/11 National Child Measurement Programme and used a cross-classified multi-level approach to examine associations between food retailing and BMI z-scores. Analyses were stratified among Reception (aged 4-5 and Year 6 (aged 10-11 students to measure associations across the primary school years.Our multilevel model had three levels to account for individual (n = 16,956, home neighbourhood (n = 664 and school (n = 268 factors. After controlling for confounders, there were no significant associations between retailing near schools and student BMI, but significant positive associations between fast food outlets in home neighbourhood and BMI z-scores. Year 6 students living in areas with the highest density of fast food outlets had an average BMI z-score that was 0.12 (95% CI: 0.04, 0.20 higher than those living in areas with none.We found little evidence to suggest that food retailing around schools influences student BMI. There is some evidence to suggest that fast food outlet densities in a child's home neighbourhood may have an effect on BMI

  5. Evaluation of Partial Cut-out of Sacroiliac Screws From the Sacral Ala Slope via Pelvic Inlet and Outlet View.

    Science.gov (United States)

    Zhang, Jingwei; Hamilton, Ryan; Li, Ming; Ebraheim, Nabil A; He, Xianfeng; Liu, Jiayong; Zhu, Limei

    2015-12-01

    An anatomic and radiographic study of placement of sacroiliac screws. The aim of this study was to quantitatively assess the risk of partial cut-out of sacroiliac screws from the sacral ala slope via inlet and outlet view. The partial cut-out of sacroiliac screws from the superior surface of sacral ala can jeopardize the L5 nerve root, which is difficult to identify on the pelvic inlet and outlet views. Computed tomography images of 60 patients without pelvic ring deformity or injury were used to measure the width (on inlet view) and height (on outlet view) of the sacral ala. The angle of the sacral ala slope was measured on lateral view. According to the measured parameters, the theoretical safe trajectories of screw placement were calculated using inverse trigonometric functions. Under fluoroscopic guidance, a sacroiliac screw was placed close to the midline on both inlet and outlet views, including posterosuperior, posteroinferior, anterosuperior, and anteroinferior regions to the midline. The incidence of screw partial cut-out from the superior surface of sacral ala was identified. The measured widths and heights of the sacral alas were 28.1 ± 2.8 and 29.8 ± 3.1 mm, respectively. The average angle between the superior aspect of the S1 vertebral body and the superior aspect of the sacral ala was 37.2 ± 2.5 degrees. The rate of partial cut-out of the screws from the superior surface of sacral ala slope was 12.5% (5/40) in posterosuperior, 0% (0/40) in posteroinferior, 70% (28/40) in anterosuperior, and 20% (8/40) in anteroinferior. To avoid the risk of partial cut-out from sacroiliac screw placement, more precise description should be added to the conventional description: the sacroiliac screws should be placed at the inferior half portion on outlet view and at the posterior half portion on inlet view. 4.

  6. Tobacco outlet density, retailer cigarette sales without ID checks and enforcement of underage tobacco laws: associations with youths' cigarette smoking and beliefs.

    Science.gov (United States)

    Lipperman-Kreda, Sharon; Grube, Joel W; Friend, Karen B; Mair, Christina

    2016-03-01

    To estimate the relationships of tobacco outlet density, cigarette sales without ID checks and local enforcement of underage tobacco laws with youth's life-time cigarette smoking, perceived availability of tobacco and perceived enforcement of underage tobacco laws and changes over time. The study involved: (a) three annual telephone surveys, (b) two annual purchase surveys in 2000 tobacco outlets and (c) interviews with key informants from local law enforcement agencies. Analyses were multi-level models (city, individual, time). A sample of 50 mid-sized non-contiguous cities in California, USA. A total of 1478 youths (aged 13-16 at wave 1, 52.2% male); 1061 participated in all waves. Measures at the individual level included life-time cigarette smoking, perceived availability and perceived enforcement. City-level measures included tobacco outlet density, cigarette sales without ID checks and compliance checks. Outlet density was associated positively with life-time smoking [OR = 1.12, P Sales rate without checking IDs was related to greater perceived availability (β = 0.01, P sales without ID checks and enforcement levels may influence beliefs about access to cigarettes and enforcement of underage tobacco sales laws. © 2015 Society for the Study of Addiction.

  7. Parameter optimization through performance analysis of model based control of a batch heat treatment furnace with low NO x radiant tube burner

    International Nuclear Information System (INIS)

    Tiwari, Manish Kumar; Mukhopadhyay, Achintya; Sanyal, Dipankar

    2005-01-01

    A model based control structure for heat treating a 0.5% C steel slab in a batch furnace with low NO x radiant tube burner is designed and tested for performance to yield optimal parameter values using the model developed in the companion paper. Combustion is considered in a highly preheated and product gas diluted mode. Controlled combustion with a proposed arrangement for preheating and diluting the air by recirculating the exhaust gas that can be retrofitted with an existing burner yields satisfactory performance and emission characteristics. Finally, the effect of variable property considerations are presented and critically analyzed

  8. Antenatal and postnatal sonographic imaging findings of a single ventricle presenting as double outlet right ventricle with rudimentary left ventricle and single atrium

    Directory of Open Access Journals (Sweden)

    Donboklang Lynser

    2015-11-01

    Full Text Available Congenital heart disease is a major cause of morbidity and mortality. Single ventricle is a rare finding and usually of left ventricular morphology. We present here interesting antenatal and postnatal echocardiographic findings of a baby having a rare single ventricle of right ventricular morphology with double outlet. Antenatally we saw a large ventricular septal defect indistinguishable from a single ventricle with left to right ventricular ratio of 1:1. Postnatally we saw a single ventricle having the outlets for both the main pulmonary artery and aortic root. The left ventricle is collapse with a rudimentary morphology possibly due to changes in hemodynamics after birth and absent of outlet from it.

  9. Internal Flow of a High Specific-Speed Diagonal-Flow Fan (Rotor Outlet Flow Fields with Rotating Stall

    Directory of Open Access Journals (Sweden)

    Norimasa Shiomi

    2003-01-01

    Full Text Available We carried out investigations for the purpose of clarifying the rotor outlet flow fields with rotating stall cell in a diagonal-flow fan. The test fan was a high–specific-speed (ns=1620 type of diagonal-flow fan that had 6 rotor blades and 11 stator blades. It has been shown that the number of the stall cell is 1, and its propagating speed is approximately 80% of its rotor speed, although little has been known about the behavior of the stall cell because a flow field with a rotating stall cell is essentially unsteady. In order to capture the behavior of the stall cell at the rotor outlet flow fields, hot-wire surveys were performed using a single-slant hotwire probe. The data obtained by these surveys were processed by means of a double phase-locked averaging technique, which enabled us to capture the flow field with the rotating stall cell in the reference coordinate system fixed to the rotor. As a result, time-dependent ensemble averages of the three-dimensional velocity components at the rotor outlet flow fields were obtained. The behavior of the stall cell was shown for each velocity component, and the flow patterns on the meridional planes were illustrated.

  10. Characteristics of evacuated tubular solar thermal collector as input energy for cooling system at Universitas Indonesia

    Science.gov (United States)

    Alhamid, M. Idrus; Nasruddin, Aisyah, Nyayu; Sholahudin

    2017-03-01

    This paper discussed the use of solar thermal collector as an input energy for cooling system. The experimental investigation was undertaken to characterize solar collectors that have been integrated with an absorption chiller. About 62 modules of solar collectors connected in series and parallel are placed on the roof top of MRC building. Thermistors were used to measure the fluid temperature at inlet, inside and outlet of each collector, inside the water tank and ambient temperature. Water flow that circulated from the storage was measured by flow meter, while solar radiation was measured by a pyranometer that was mounted parallel to the collector. Experimental data for a data set was collected in March 2016, during the day time hours of 08:00 - 17:00. This data set was used to calculate solar collector efficiency. The results showed that in the maximum solar radiation, the outlet temperature that can be reached is about 78°C, the utilized energy is about 70 kW and solar collector has an efficiency of 64%. While in the minimum solar radiation, the outlet temperature that can be reached is about 53°C, the utilized energy is about 28 kW and solar collector has an efficiency of 43%.

  11. A GIS Application to Explore Postal Retail Outlet Locations

    Directory of Open Access Journals (Sweden)

    Nikola Trubint

    2012-03-01

    Full Text Available The use of GIS in solving a wide variety of problems in postal operations is expanding. This approach provides the development and usage of new methods in spatial data analysis, as support in achieving a better quality of the decision-making process. The use of location analysis model based on GIS software is implemented in solving the Belgrade postal retail outlet problem. One of the most important experiences of model implementation is that the local environmental conditions have a significant impact on strategic as well as operational approach. A portion of the material included in the paper has resulted from the Serbian PTT and CPC (Canada Post Corporation joint project Location Analysis.

  12. The 'Ball children' juggle with ''solar'' and ''all-electrical'' energy...; Les ''enfants de la balle'' jonglent avec le ''solaire'' et le ''tout electrique''...

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-05-01

    The Fratellini circus academy, settled in the north of Paris (France), has chosen technical energy solutions adapted to each building with respect to its vocation. These solutions combine helio-atmospheric solar collectors, heat pumps, convectors and radiant heating systems. (J.S.)

  13. Knowledge of practising radiographers of the supraspinatus outlet projection for shoulder impingement syndrome in the Eastern Cape, South Africa

    International Nuclear Information System (INIS)

    Williams, R.; Morton, D.G.

    2016-01-01

    Background/Aim: There are many projections in plain film imaging to demonstrate the specific aspects of the anatomy of the shoulder. However, reproducing the required projections can be challenging especially if radiographers are not familiar with the projections and their evaluation criteria. The aim of the study was to explore and describe the knowledge of practising radiographers regarding the supraspinatus outlet projection for shoulder impingement syndrome. Method: A quantitative, exploratory and descriptive design was followed. The population served as the sample and included all the practising radiographers in the public and private hospitals of a metropolitan municipality in the Eastern Cape, South Africa. A total of 84 respondents completed the structured, self-administered questionnaire. Results: The data revealed that in many cases, the majority of radiographers in the study, due to inadequate knowledge levels would not be able to produce an optimal radiographic image of the supraspinatus outlet. The results of the chi-squares indicated statistically significant differences (p < 0.05) between public and private hospitals regarding certain aspects of the scapular Y projection and SOP. Conclusion: It was found that the radiographers in the study had inadequate knowledge of scapular Y projections and SOPs in relation to SIS. Therefore, it is essential to ensure that radiographers are updated on their knowledge of radiographic practice on a continuous basis. - Highlights: • Many radiographers unable to produce an optimal image of the supraspinatus outlet. • Radiographers had poor knowledge of scapular Y and supraspinatus outlet projections. • It is essential that radiographers update their knowledge of radiographic practice.

  14. Self-expandable metal stents for malignant gastric outlet obstruction: A pooled analysis of prospective literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; Rauws, Erik A. J.; Fockens, Paul; van Hooft, Jeanin E.

    2015-01-01

    To provide an overview of the clinical outcomes of self-expandable metal stent (SEMS) placement for malignant gastric outlet obstruction (MGOO). A systematic literature search was performed in PubMed of the literature published between January 2009 and March 2015. Only prospective studies that

  15. Application of the grey system theory for forecasting the content of 238U in soil near a uranium mine exhaust outlet

    International Nuclear Information System (INIS)

    Ye Yongjun; Ding Dexin; Li Xiangyang; Zhou Xinghuo; Liu Dong

    2008-01-01

    In order to forecast the content of 238 U in soil near a uranium mine exhaust outlet, a general GM(1,1) forecasting model was established based on grey system theory, analyzing association degree and residual error distinction. According to the measuring datum of the content of 238 U in soil near a uranium mine exhaust outlet from 2001 to 2006, used the model to forecast the content of 238 U in soil, The results show that the forecasting value agrees with the measuring results and the forecasting precision is higher; at the same time the content of 238 U in soil in 2007 is also forecasted based on the model, the relative error was 4.8%; which shows the GM(1,1) forecasting model has higher practical value, and is a effective method for forecasting the content of 238 U in soil near a uranium mine exhaust outlet. (authors)

  16. Eating at Food Outlets and "On the Go" Is Associated with Less Healthy Food Choices in Adults: Cross-Sectional Data from the UK National Diet and Nutrition Survey Rolling Programme (2008-2014).

    Science.gov (United States)

    Ziauddeen, Nida; Almiron-Roig, Eva; Penney, Tarra L; Nicholson, Sonja; Kirk, Sara F L; Page, Polly

    2017-12-02

    Eating location has been linked with variations in diet quality including the consumption of low-nutrient energy-dense food, which is a recognised risk factor for obesity. Cross-sectional data from 4736 adults aged 19 years and over from Years 1-6 of the UK National Diet and Nutrition Survey (NDNS) Rolling Programme (RP) (2008-2014) were used to explore food consumption patterns by eating location. Eating location was categorized as home, work, leisure places, food outlets and "on the go". Foods were classified into two groups: core (included in the principal food groups and considered important/acceptable within a healthy diet) and non-core (all other foods). Out of 97,748 eating occasions reported, the most common was home (67-90% of eating occasions). Leisure places, food outlets and "on the go" combined contributed more energy from non-core (30%) than from core food (18%). Analyses of modulating factors revealed that sex, income, frequency of eating out and frequency of drinking were significant factors affecting consumption patterns ( p eating patterns, behaviours and resulting diet quality vary by location. Public health interventions should focus on availability and access to healthy foods, promotion of healthy food choices and behaviours across multiple locations, environments and contexts for food consumption.

  17. Healthier choices in an Australian health service: a pre-post audit of an intervention to improve the nutritional value of foods and drinks in vending machines and food outlets.

    Science.gov (United States)

    Bell, Colin; Pond, Nicole; Davies, Lynda; Francis, Jeryl Lynn; Campbell, Elizabeth; Wiggers, John

    2013-11-25

    Vending machines and shops located within health care facilities are a source of food and drinks for staff, visitors and outpatients and they have the potential to promote healthy food and drink choices. This paper describes perceptions of parents and managers of health-service located food outlets towards the availability and labelling of healthier food options and the food and drinks offered for sale in health care facilities in Australia. It also describes the impact of an intervention to improve availability and labelling of healthier foods and drinks for sale. Parents (n = 168) and food outlet managers (n = 17) were surveyed. Food and drinks for sale in health-service operated food outlets (n = 5) and vending machines (n = 90) in health care facilities in the Hunter New England region of NSW were audited pre (2007) and post (2010/11) the introduction of policy and associated support to increase the availability of healthier choices. A traffic light system was used to classify foods from least (red) to most healthy choices (green). Almost all (95%) parents and most (65%) food outlet managers thought food outlets on health service sites should have signs clearly showing healthy choices. Parents (90%) also thought all food outlets on health service sites should provide mostly healthy items compared to 47% of managers. The proportion of healthier beverage slots in vending machines increased from 29% to 51% at follow-up and the proportion of machines that labelled healthier drinks increased from 0 to 26%. No outlets labelled healthier items at baseline compared to 4 out of 5 after the intervention. No changes were observed in the availability or labelling of healthier food in vending machines or the availability of healthier food or drinks in food outlets. Baseline availability and labelling of healthier food and beverage choices for sale in health care facilities was poor in spite of the support of parents and outlet managers for such initiatives. The intervention

  18. Surface Elevation Change of Transantarctic Outlet Glaciers using Historical Aerial Imagery and Structure-from-Motion Photogrammetry

    Science.gov (United States)

    Child, S. F.; Stearns, L. A.; Girod, L.

    2017-12-01

    Transantarctic Mountain outlet glaciers drain ice from the East Antarctic Ice Sheet to the Ross Ice Shelf and are generally considered to be stable. However, studies that assess these glaciers typically use data with coarse spatial resolutions (1 - 20 km) and span only the last 15 - 20 years. Here, we use trimetrogon aerial (TMA) photographs collected by the United States Geological Survey from 1960 - 1965 to create historical surface elevation maps. We construct elevations from both the vertical (0° nadir) and oblique photographs using MicMac, a Structure-from-Motion (SfM) software. With typical SfM processing, accurate ground control points (GCPs) are necessary for the best results; however, in situ GCPs are extremely sparse in Antarctica, so we manually identify GCPs using exposed rock outcrops in the WorldView imagery. The historical glacier surface elevations are then compared with present-day elevations derived from WorldView imagery. With this methodology, we assess how Transantarctic outlet glaciers have changed over 55 years. Recent studies indicate thinning of the eastern Ross Ice Shelf, where it borders the Transantarctic Mountains. With long-term records of glacier elevation change, we can differentiate whether ice shelf thinning is driven by changes in glacier or ocean dynamics. These results give us a better understanding of the long-term stability of East Antarctic outlet glaciers, which is essential in improving predictive models of ice sheet behavior.

  19. Modeling of radiant heat transfers in non-grey gases using the discrete ordinate method in association with a narrow bands statistical model; Modelisation des transferts radiatifs dans des gaz non gris par la methode des ordonnees discretes associee a un modele statistique a bandes etroites

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, A.B. de; Delmas, A; Sacadura, J F [Institut National des Sciences Appliquees (INSA), 69 - Villeurbanne (France)

    1997-12-31

    A formulation based on the use of the discrete ordinate method applied to the integral form of the radiant heat transfer equation is proposed for non-grey gases. The correlations between transmittances are neglected and no explicit wall reflexion is considered. The configuration analyzed consists in a flat layer of non-isothermal steam-nitrogen mixture. Cavity walls are grey with diffuse reflexion and emission. A narrow band statistical model is used to represent the radiative properties of the gas. The distribution of the radiative source term inside the cavity is calculated along two temperature profiles in a uniform steam concentration. Results obtained using this simplified approach are in good agreement with those found in the literature for the same temperature and concentration distributions. This preliminary study seems to indicate that the algorithm based on the integration of radiant heat transfer along the luminance path is less sensitive to de-correlation effects than formulations based on the differential form the the radiant heat transfer. Thus, a more systematic study of the influence of the neglecting of correlations on the integral approach is analyzed in this work. (J.S.) 16 refs.

  20. Modeling of radiant heat transfers in non-grey gases using the discrete ordinate method in association with a narrow bands statistical model; Modelisation des transferts radiatifs dans des gaz non gris par la methode des ordonnees discretes associee a un modele statistique a bandes etroites

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, A.B. de; Delmas, A.; Sacadura, J.F. [Institut National des Sciences Appliquees (INSA), 69 - Villeurbanne (France)

    1996-12-31

    A formulation based on the use of the discrete ordinate method applied to the integral form of the radiant heat transfer equation is proposed for non-grey gases. The correlations between transmittances are neglected and no explicit wall reflexion is considered. The configuration analyzed consists in a flat layer of non-isothermal steam-nitrogen mixture. Cavity walls are grey with diffuse reflexion and emission. A narrow band statistical model is used to represent the radiative properties of the gas. The distribution of the radiative source term inside the cavity is calculated along two temperature profiles in a uniform steam concentration. Results obtained using this simplified approach are in good agreement with those found in the literature for the same temperature and concentration distributions. This preliminary study seems to indicate that the algorithm based on the integration of radiant heat transfer along the luminance path is less sensitive to de-correlation effects than formulations based on the differential form the the radiant heat transfer. Thus, a more systematic study of the influence of the neglecting of correlations on the integral approach is analyzed in this work. (J.S.) 16 refs.